Jírová, Dagmar; Basketter, David; Liebsch, Manfred; Bendová, Hana; Kejlová, Kristina; Marriott, Marie; Kandárová, Helena
2010-02-01
Efforts to replace the rabbit skin irritation test have been underway for many years, encouraged by the EU Cosmetics Directive and REACH. Recently various in vitro tests have been developed, evaluated and validated. A key difficulty in confirming the validity of in vitro methods is that animal data are scarce and of limited utility for prediction of human effects, which adversely impacts their acceptance. This study examines whether in vivo or in vitro data most accurately predicted human effects. Using the 4-hr human patch test (HPT) we examined a number of chemicals whose EU classification of skin irritancy is known to be borderline, or where in vitro methods provided conflicting results. Of the 16 chemicals classified as irritants in the rabbit, only five substances were found to be significantly irritating to human skin. Concordance of the rabbit test with the 4-hr HPT was only 56%, whereas concordance of human epidermis models with human data was 76% (EpiDerm) and 70% (EPISKIN). The results confirm observations that rabbits overpredict skin effects in humans. Therefore, when validating in vitro methods, all available information, including human data, should be taken into account before making conclusions about their predictive capacity.
Effect of nano-silver hydrogel coating film on deep partial thickness scald model of rabbit.
Xi, Peng; Li, Yan; Ge, Xiaojin; Liu, Dandan; Miao, Mingsan
2018-05-01
Observing the effect of nano-silver hydrogel coating film on deep partial thickness scald model of rabbit. We prepared boiling water scalded rabbits with deep II degree scald models and applied high, medium and low doses of nano-silver hydrogel coating film for different time and area. Then we compared the difference of burned paper weight before administration and after administration model burns, burn local skin irritation points infection, skin crusting and scabs from the time, and the impact of local skin tissue morphology. Rabbits deep II degree burn model successful modeling; on day 12, 18, high, medium and low doses of nano-silver hydrogel coating film significantly reduced skin irritation of rabbits infected with the integral value ( P < 0.01, P < 0.05); high, medium and low doses of nano-silver hydrogel coating film group significantly decreased skin irritation, infection integral value ( P < 0.01, P < 0.05); high, medium and low doses of nano-silver hydrogel coating film significantly reduced film rabbits' scalded skin crusting time ( P < 0.01), significantly shortened the rabbit skin burns from the scab time ( P < 0.01), and significantly improved the treatment of skin diseases in rabbits scald model change ( P < 0.01, P < 0.05). The nano-silver hydrogel coating film on the deep partial thickness burns has a significant therapeutic effect; external use has a significant role in wound healing.
Amasa, Wayessa; Santiago, Dante; Mekonen, Seblework; Ambelu, Argaw
2012-01-01
Background. Rabbit skin model was used to test skin irritation of the most commonly used cosmetic products in Jimma town, southwestern Ethiopia. The most commonly used cosmetics were Dove, Glysolid, College, Top Society, Fair and Lovely, Nivea, Lux, Magic fruit world, Solea, Body talk, Kris, Holly, Victoria, and Sweet Heart. Methods. Intact and abraded rabbit skins were tested for erythema and edema under shade and under sun exposure. Draize Primary Irritation Index (PII) was used to calculate skin irritation of each cosmetic. Cosmetic ingredients were analyzed from the labels. Results and Discussion. Only Dove cream caused no skin irritation except for an abraded skin under sun exposure for five consecutive days. It has been identified that application of cosmetics on abraded skin under sunny condition worsens the irritation. Cosmetic labels revealed that most ingredients used in all products were those restricted chemicals due to their adverse health effects. Conclusion. This study has concluded that use of cosmetics under sunshine and also on abraded skin increases skin irritation. Hence, those users who have abraded skin are advised not to apply those cosmetics on continuous basis specifically under sun exposure. PMID:23209460
Experimental study on skin irritation of bone spur powder on rabbit
NASA Astrophysics Data System (ADS)
Ma, Zhenzhen; Zhang, Xuhui; Hao, Shaojun; Shen, Huiling; Wang, Huamin; Ji, Xianghui; Zhang, Zhengchen; Huang, Youling
2018-04-01
To observe the effect of bone powder of rabbit skin, provide the basis for the safety of clinical use of bone powder, 24 rabbits were randomly divided into 6 groups, complete skin test and damaged skin test each divided into 3 groups (n=4), high, low, 3 doses tested daily administered 1 times, continuous administration for 7 days, in 24 hours after the last administration of drug residues, wash with warm water, the removal of L hours after drug for 24 hours, 48 hours, 72 hours and seventh days, observed and recorded to apply position before administration and administration during the skin no erythema and edema, and observe the smear Parts of any pigmentation, bleeding, rough skin or thin skin etc., record the occurrence time and duration time. Through comparative observation, intact skin group before administration and dosing period, there were no erythema and edema, pigmentation, bleeding, rough skin or thin skin etc., there is no difference with the control group; the damaged skin group after administration of 1 to 5 days, each rabbit skin there are different degrees of erythema and edema, especially to skin injury after 24-48 hours is obvious, 2 days (48 hours) after 4 days gradually reduced, significantly subsided after 6 days, erythema and edema phenomenon subsided completely, not out of blood, pigmentation, rough skin or thin skin and so on. The bone spur powder has no irritation on the intact skin of rabbits. The bone spur powder has moderate irritation on the damaged skin of rabbits, but after 48 hours, the stimulation reaction subsided spontaneously, which is caused by the inflammatory reaction caused by skin injury, rather than the medication. The bone spur powder is safe for clinical use.
Macfarlane, Martin; Jones, Penny; Goebel, Carsten; Dufour, Eric; Rowland, Joanna; Araki, Daisuke; Costabel-Farkas, Margit; Hewitt, Nicola J; Hibatallah, Jalila; Kirst, Annette; McNamee, Pauline; Schellauf, Florian; Scheel, Julia
2009-07-01
Evaluation of the skin irritancy and corrosivity potential of an ingredient is a necessity in the safety assessment of cosmetic ingredients. To date, there are two formally validated alternatives to the rabbit Draize test for skin corrosivity in place, namely the rat skin transcutaneous electrical resistance (TER) assay and the Human Skin Model Test using EpiSkin, EpiDerm and SkinEthic reconstructed human epidermal equivalents. For skin irritation, EpiSkin, EpiDerm and SkinEthic are validated as stand-alone test replacements for the rabbit Draize test. Data from these tests are rarely considered in isolation and are evaluated in combination with other factors to establish the overall irritating or corrosive potential of an ingredient. In light of the deadlines established in the Cosmetics Directive for cessation of animal testing for cosmetic ingredients, a COLIPA scientific meeting was held in Brussels on 30th January, 2008 to review the use of alternative approaches and to set up a decision tree approach for their integration into tiered testing strategies for hazard and safety assessment of cosmetic ingredients and their use in products. In conclusion, the safety assessments for skin irritation/corrosion of new chemicals for use in cosmetics can be confidently accomplished using exclusively alternative methods.
Yamamoto, Nobuyuki; Miyamoto, Koji; Katoh, Masakazu
2010-08-01
Alcohol-based hand rubs are widely used for infection control in clinical practice. However, it is known that frequent use of the alcohol-based hand rubs may cause skin irritation. To predict the skin irritation in human, animal experiments are quite useful. Especially, the Draize Test using rabbits is suitable for this purpose because their skin is highly sensitive. On the other hand, the development of alternative to animal experiments is important not only from the viewpoint of ethical aspects but also from the efficient research and development. Reconstructed human epidermis (RhE) was developed as a human skin equivalent model in vitro, and has been applied to the evaluation of skin irritation. But the RhE has not been utilized for the evaluation of alcohol-based hand rubs because of the high skin permeability and cytotoxicity of alcohols. The aim of this study was to develop a new method using the RhE in evaluation of skin irritation caused by alcohol-based hand rubs. The authors propose an experimental technique named "Skin model blowing method (SMBM)" consisting of the sequential procedure as follows; applying small amount of testing sample on RhE, blow-dry, post incubation, and cell viability measurement. According to the SMBM, the skin irritation caused by alcohol-based hand rubs could be evaluated under the similar condition of their actual use. It was found that a high correlation existed between the cell viability obtained from SMBM and the skin irritation index in rabbit which had been reported previously.
2014-08-29
about exposure to spills of any kind, direct dermal exposure to jet fuel or solvent or other exposures such as cleaning fluids and smoking (if a smoker ...additives, may influence toxicity during exposure. JP-8 was found to be non -irritating in the rabbit primary eye irritation test (Smith et al...1981; Kinkead et al., 1992a). Results in the corresponding rabbit skin irritation test ranged from non -irritating (Smith et al., 1981; Wolfe et al
Piret, Jocelyne; Laforest, Geneviève; Bussières, Martin; Bergeron, Michel G
2008-03-01
The safety of an ethylene oxide/propylene oxide gel formulation containing sodium lauryl sulfate (2%, w/w), that could be a potent candidate as a topical microbicide, has been evaluated. More specifically, the subchronic (26- and 52-week) toxicity of the formulation when applied intravaginally as well as its irritating potential for the rectal, penile, eye, skin and buccal mucosa have been examined in animal models. The results showed that the vaginal administration of the gel formulation containing sodium lauryl sulfate once and twice daily (with doses 12 +/- 2 h apart) for 26 weeks to rats and for 52 weeks to rabbits induced slight to moderate histopathological alterations. When the formulation was applied intrarectally to male and female rabbits once and twice daily (with doses 12 +/- 2 h apart) for 14 days, no macroscopic or microscopic changes were reported. For both vaginal and rectal dosing, no effect was seen on the haematology, coagulation and serum chemistry parameters as well as on the body weight of animals and the relative organ weights. Other sporadic macroscopic and histopathological findings were incidental in origin and of no toxicological significance. The gel formulation containing sodium lauryl sulfate was considered as mildly irritating for the penile mucosa of rabbits, non-irritating for the eye of rabbits, mildly irritating for the skin in a rabbit model and non-irritating for the hamster cheek pouch. It is suggested that the gel formulation containing sodium lauryl sulfate is safe for most tissues that could be exposed to the product under normal use.
An approach for development of alternative test methods based on mechanisms of skin irritation.
Osborne, R; Perkins, M A
1994-02-01
Recent advances in techniques for culture of human skin cells have led to their potential for use as in vitro models for skin irritation testing to augment or replace existing rabbit skin patch tests. Our work is directed towards the development of cultured human skin cells, together with endpoints that can be linked to in vivo mechanisms of skin irritation, as in vitro models for prediction of human skin irritation, and for study of mechanisms of contact irritant dermatitis. Three types of commercial human skin cell cultures have been evaluated, epidermal keratinocytes and partially or fully cornified keratinocyte-dermal fibroblast co-cultures. Human epidermal keratinocyte cultures (Clonetics) were treated with product ingredients and formulations, and the extent of cell damage was assessed by incorporation of the vital dye neutral red. Cell damage correlated with human skin patch data for ingredient chemicals with the exception of acids and alkalis, but did not correlate with skin irritation to surfactant-containing product formulations. Cultures of human skin equivalents were evaluated as potential models for measurement of responses to test materials that could not be measured in the keratinocyte/neutral red assay. We developed a battery of in vitro endpoints to measure responses to prototype ingredients and formulations in human epidermal keratinocyte-dermal fibroblast co-cultures grown on a nylon mesh ('Skin2' from Advanced Tissue Sciences) or on a collagen gel ('Testskin' from Organogenesis). The endpoints measure cytotoxicity (neutral red and MTT vital dye staining, lactate dehydrogenase and N-acetyl glucosaminidase release, glucose utilization) and inflammatory mediator (prostaglandin E2) release. Initial experiments indicate a promising correlation between responses of the Skin2 model to prototype surfactants and in vivo human skin irritation. The responses of Testskin cultures to acids and alkalis help to prove the concept that a topical application model can measure responses to these materials. These results suggest that human skin cell models can provide useful systems for preclinical skin irritation assessments, as alternatives to rabbits, for at least certain classes of test substances.
Lee, Miri; Hwang, Jee-Hyun; Lim, Kyung-Min
2017-01-01
Human eyes and skin are frequently exposed to chemicals accidentally or on purpose due to their external location. Therefore, chemicals are required to undergo the evaluation of the ocular and dermal irritancy for their safe handling and use before release into the market. Draize rabbit eye and skin irritation test developed in 1944, has been a gold standard test which was enlisted as OECD TG 404 and OECD TG 405 but it has been criticized with respect to animal welfare due to invasive and cruel procedure. To replace it, diverse alternatives have been developed: (i) For Draize eye irritation test, organotypic assay, in vitro cytotoxicity-based method, in chemico tests, in silico prediction model, and 3D reconstructed human cornea-like epithelium (RhCE); (ii) For Draize skin irritation test, in vitro cytotoxicity-based cell model, and 3D reconstructed human epidermis models (RhE). Of these, RhCE and RhE models are getting spotlight as a promising alternative with a wide applicability domain covering cosmetics and personal care products. In this review, we overviewed the current alternatives to Draize test with a focus on 3D human epithelium models to provide an insight into advancing and widening their utility. PMID:28744350
Biological Evaluation of the Copper/Low-density Polyethylene Nanocomposite Intrauterine Device
Wang, Hong; Li, Jun; Xie, Changsheng; Duan, Zhuo; Sun, Li-Kui; Wang, Xin; Zhu, Changhong
2013-01-01
Devices and materials intended for clinical applications as medical and implant devices should be evaluated to determine their biocompatibility in physiological systems. This article presents results from cytotoxicity assay of L929 mouse fibroblasts culture, tests for skin irritation, intracutaneous reactivity and sensitization, and material implantation tests for the novel copper/low-density polyethylene nanocomposite intrauterine device (nano-Cu/LDPE IUD) with potential for future clinical utilization. Cytotoxicity test in vitro was conducted to evaluate the change in morphology, growth and proliferation of cultured L929 mouse fibroblasts, which in vivo examination for skin irritation (n = 6) and intracutaneous reactivity (n = 6) were carried out to explore the irritant behavior in New Zealand White rabbits. Skin sensitization was implemented to evaluate the potential skin sensitizing in Hartley guinea pigs (n = 35). The materials were implanted into the spinal muscle of rabbits (n = 9). The cytotoxicity grade of the nano-Cu/LDPE IUD was 0–1, suggested that the composite was nontoxic or mildly cytotoxic; no irritation reaction and skin sensitization were identified in any animals of specific extracts prepared from the material under test; similarly to the control sides, the inflammatory reaction was observed in the rabbits living tissue of the implanted material in intramuscular implantation assay. They indicated that the novel composite intrauterine device presented potential for this type of application because they meet the requirements of the standard practices recommended for evaluating the biological reactivity. The nano-Cu/LDPE IUD has good biocompatibility, which is biologically safe for the clinical research as a novel contraceptive device. PMID:24058521
Biological evaluation of the copper/low-density polyethylene nanocomposite intrauterine device.
Hu, Li-Xia; He, Jing; Hou, Li; Wang, Hong; Li, Jun; Xie, Changsheng; Duan, Zhuo; Sun, Li-Kui; Wang, Xin; Zhu, Changhong
2013-01-01
Devices and materials intended for clinical applications as medical and implant devices should be evaluated to determine their biocompatibility in physiological systems. This article presents results from cytotoxicity assay of L929 mouse fibroblasts culture, tests for skin irritation, intracutaneous reactivity and sensitization, and material implantation tests for the novel copper/low-density polyethylene nanocomposite intrauterine device (nano-Cu/LDPE IUD) with potential for future clinical utilization. Cytotoxicity test in vitro was conducted to evaluate the change in morphology, growth and proliferation of cultured L929 mouse fibroblasts, which in vivo examination for skin irritation (n = 6) and intracutaneous reactivity (n = 6) were carried out to explore the irritant behavior in New Zealand White rabbits. Skin sensitization was implemented to evaluate the potential skin sensitizing in Hartley guinea pigs (n = 35). The materials were implanted into the spinal muscle of rabbits (n = 9). The cytotoxicity grade of the nano-Cu/LDPE IUD was 0-1, suggested that the composite was nontoxic or mildly cytotoxic; no irritation reaction and skin sensitization were identified in any animals of specific extracts prepared from the material under test; similarly to the control sides, the inflammatory reaction was observed in the rabbits living tissue of the implanted material in intramuscular implantation assay. They indicated that the novel composite intrauterine device presented potential for this type of application because they meet the requirements of the standard practices recommended for evaluating the biological reactivity. The nano-Cu/LDPE IUD has good biocompatibility, which is biologically safe for the clinical research as a novel contraceptive device.
Rivers, Thomas M.; Tillett, William S.
1923-01-01
1. The localization of the virus of varicella in the human skin is influenced by irritation. This is indirect evidence that the virus is in the blood. 2. Rabbits are susceptible to a virus recovered from the blood of varicella patients. 3. Testicular emulsions containing the virus are free from ordinary aerobic and anaerobic bacteria, and produce lesions in the cornea, skin, and testicles of rabbits. 4. The virus can be transmitted indefinitely from rabbit to rabbit by means of testicular inoculation, and can be preserved 29 days in 50 per cent glycerol at a low temperature. PMID:19868818
Lönnqvist, Susanna; Briheim, Kristina; Kratz, Gunnar
2016-02-01
Testing of irritant compounds has traditionally been performed on animals and human volunteers. Animal testing should always be restricted and for skin irritancy mice and rabbits hold poor predictive value for irritant potential in humans. Irritant testing on human volunteers is restricted by the duration subjects can be exposed, and by the subjectivity of interpreting the visual signs of skin irritation. We propose an irritant testing system using viable human full thickness skin with the loss of cell viability in the exposed skin area as end point measurement. Skin was exposed to sodium dodecyl sulfate (SDS) at 20% concentration by non-occluded topical exposure to establish a positive control response and subsequent test compounds were statistically compared with the 20% SDS response. Cell viability and metabolism were measured with 3-(4,5-dimethyl-thiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. The model presents correlation between increased concentration of SDS and decreased viability of cells in the exposed skin area (R(2) = 0.76). We propose the model to be used for cytotoxicity testing of irritant compounds. With fully intact barrier function, the model comprises all cells present in the skin with quantifiable end point measurement.
Kim, Jin Sik; Song, Kyung Seuk; Sung, Jae Hyuck; Ryu, Hyun Ryol; Choi, Byung Gil; Cho, Hyun Sun; Lee, Jin Kyu; Yu, Il Je
2013-08-01
To clarify the health risks related to silver nanoparticles (Ag-NPs), we evaluated the genotoxicity, acute oral and dermal toxicity, eye irritation, dermal irritation and corrosion and skin sensitisation of commercially manufactured Ag-NPs according to the OECD test guidelines and GLP. The Ag-NPs were not found to induce genotoxicity in a bacterial reverse mutation test and chromosomal aberration test, although some cytotoxicity was observed. In acute oral and dermal toxicity tests using rats, none of the rats showed any abnormal signs or mortality at a dose level of ∼ 2000 mg/kg. Similarly, acute eye and dermal irritation and corrosion tests using rabbits revealed no significant clinical signs or mortality and no acute irritation or corrosion reaction for the eyes and skin. In a skin sensitisation test using guinea pigs, one animal (1/20) showed discrete or patchy erythema, thus Ag-NPs can be classified as a weak skin sensitiser.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, G.; Martens, M.; Mosselmans, G.
1987-12-01
In this study, solvents belonging to different chemical families were tested for their irritating properties to the skin. The irritating potential of a chemical is expressed as its concentration in a nonirritant diluent beyond which irritation of the skin may be expected in the sense of EEC Directive 79/831/EEC. The substances were applied onto the shaved skin of rabbits by means of a modified Finn chamber for 4 hr. Afterward the exposure chamber was removed and the skin cleaned. Reading of erythema and edema was performed according to the scale of Draize at 1, 24, 48, and 72 hr aftermore » the removal of the patch. On the basis of the readings obtained the different dilutions of the organic solvents tested were classified as irritant or not according to the interpretation rules laid down in EEC Directive 83/467/EEC. On the basis of the structure-activity relationships found within each chemical family the irritation potential of the other members of the family could be derived via interpolation.« less
Walters, Russel M; Gandolfi, Lisa; Mack, M Catherine; Fevola, Michael; Martin, Katharine; Hamilton, Mathew T; Hilberer, Allison; Barnes, Nicole; Wilt, Nathan; Nash, Jennifer R; Raabe, Hans A; Costin, Gertrude-Emilia
2016-12-01
The personal care industry is focused on developing safe, more efficacious, and increasingly milder products, that are routinely undergoing preclinical and clinical testing before becoming available for consumer use on skin. In vitro systems based on skin reconstructed equivalents are now established for the preclinical assessment of product irritation potential and as alternative testing methods to the classic Draize rabbit skin irritation test. We have used the 3-D EpiDerm™ model system to evaluate tissue viability and primary cytokine interleukin-1α release as a way to evaluate the potential dermal irritation of 224 non-ionic, amphoteric and/or anionic surfactant-containing formulations, or individual raw materials. As part of our testing programme, two representative benchmark materials with known clinical skin irritation potential were qualified through repeated testing, for use as references for the skin irritation evaluation of formulations containing new surfactant ingredients. We have established a correlation between the in vitro screening approach and clinical testing, and are continually expanding our database to enhance this correlation. This testing programme integrates the efforts of global manufacturers of personal care products that focus on the development of increasingly milder formulations to be applied to the skin, without the use of animal testing. 2016 FRAME.
Amended final report of the safety assessment of dibutyl adipate as used in cosmetics.
Andersen, Alan
2006-01-01
Dibutyl Adipate, the diester of butyl alcohol and adipic acid, functions as a plasticizer, skin-conditioning agent, and solvent in cosmetic formulations. It is reportedly used at a concentration of 5% in nail polish and 8% in suntan gels, creams, and liquids. Dibutyl Adipate is soluble in organic solvents, but practically insoluble in water. Dibutyl Adipate does not absorb radiation in the ultraviolet (UV) region of the spectrum. Dibutyl Adipate is not toxic in acute oral or dermal animal toxicity tests. In a subchronic dermal toxicity study, 1.0 ml/kg day-1 caused a significant reduction in body weight gain in rabbits, but 0.5 ml/kg/day1 was without effect. In a study with dogs, no adverse effects were observed when an emulsion containing 6.25% Dibutyl Adipate was applied to the entire body twice a week for 3 months. Dibutyl Adipate was tested for dermal irritation using rabbits and mice and a none to minimal irritation was observed. Dibutyl Adipate at a concentration of 25% was not a sensitizer in a guinea pig maximization study. Undiluted Dibutyl Adipate was minimally irritating to the eyes of rabbits and 0.1% was nonirritating. A significant increase in fetal gross abnormalities was observed in rats given intraperitoneal injections of Dibutyl Adipate at 1.75 ml/kg on 3 separate days during gestation, but no effect was seen in animals given 1.05 ml/kg. Dibutyl Adipate was not genotoxic in either bacterial or mammalian test systems. Clinical patch tests confirmed the absence of skin irritation found in animal tests. Clinical phototoxicity tests were negative. Dibutyl Adipate at 0.1% was not an ocular irritant in two male volunteers. In a clinical test of comedogenicity, Dibutyl Adipate produced no effect. The Cosmetic Ingredient Review (CIR) Expert Panel recognized that use of Dibutyl Adipate in suntan cosmetic products will result in repeated, frequent exposure in a leave-on product. The available data demonstrate no skin sensitization or cumulative skin irritation, no comedogenicity, and no genotoxicity. Combined with the data demonstrating little acute toxicity, no skin or ocular irritation, and no reproductive or developmental toxicity, these data form an adequate basis for reaching a conclusion that Dibutyl Adipate is safe as a cosmetic ingredient in the practices of use and concentrations as reflected in this safety assessment.
Arteaga, M E; Mancebo, A; Molier, T; Gómez, D; González, C; Bada, A M; González, B; Rojas, N M; Rodríguez, G
2014-02-01
Bacillus thuringiensis (Bt) is the best known and most widely used of all pesticidal microbes. The aim of this study was to assess the toxicity of a new formulation of Bacillus thuringiensis var israelensis SH-14 in rats through acute dermal toxicity, dermal and eye irritation experiments. The acute dermal toxicity and dermal and eye irritation studies were performed using rabbits according to the United States Environmental Protection Agency guidelines 885.3100, 870.2500 and 870.2500, respectively. The skin sensitization study was carried out in accordance to the EPA OPPTS 870.2600 using guinea pigs. There was no mortality and no evidence of treatment-related toxicity in acute dermal toxicity test. No dermal responses, including erythema/eschar or edema, were found in rabbits treated with the new formulation of Bti SH-14. Minimum response was observed after eye application of test substance. No skin sensitization reactions were observed after the challenge with the new formulation of Bti SH-14 in the Bti SH-14-treated guinea pigs. In summary, the present study demonstrated that the new formulation of Bti SH-14 is not acutely toxic via dermal route, has low eye irritation and would not cause dermal irritation or hypersensitivity to tested animals. Copyright © 2013 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-04-01
... directions: “CAUTION: Do not allow rabbits, hamsters, guinea pigs, horses, or ruminants access to feeds... rare occasions, some pigs may show reddening of the skin and irritable behavior. These conditions have...
Code of Federal Regulations, 2012 CFR
2012-04-01
...: “CAUTION: Do not allow rabbits, hamsters, guinea pigs, horses, or ruminants access to feeds containing... pigs may show reddening of the skin and irritable behavior. These conditions have been self-correcting...
Code of Federal Regulations, 2014 CFR
2014-04-01
...: “CAUTION: Do not allow rabbits, hamsters, guinea pigs, horses, or ruminants access to feeds containing... pigs may show reddening of the skin and irritable behavior. These conditions have been self-correcting...
Code of Federal Regulations, 2013 CFR
2013-04-01
...: “CAUTION: Do not allow rabbits, hamsters, guinea pigs, horses, or ruminants access to feeds containing... pigs may show reddening of the skin and irritable behavior. These conditions have been self-correcting...
Code of Federal Regulations, 2011 CFR
2011-04-01
...: “CAUTION: Do not allow rabbits, hamsters, guinea pigs, horses, or ruminants access to feeds containing... pigs may show reddening of the skin and irritable behavior. These conditions have been self-correcting...
Water Quality Criteria for Colored Smokes: Solvent Green 3
1987-12-01
by the oral, dermal, or inhalation route. The acute oral LD50 is >3.16 g/kg in rats, but may be as high as 15 g/kg, >1 g/kg in dogs , and 10 g/kg in...0 is >3.16 g/kg, but may be as high as 15 g/kg in rats, >1 g/kg in dogs , and 10 g/kg in rabbits. Solvent Green 3 is not irritating to eyes and is...only mildly irritating to the skin. The acute LCt 5 0 for five experimental animal species combined (monkeys, dogs , swine, rabbits, and rats) is 319,447
Nomura, Yusuke; Lee, Michelle; Fukui, Chie; Watanabe, Kayo; Olsen, Daniel; Turley, Audrey; Morishita, Yuki; Kawakami, Tsuyoshi; Yuba, Toshiyasu; Fujimaki, Hideo; Inoue, Kaoru; Yoshida, Midori; Ogawa, Kumiko; Haishima, Yuji
2017-12-11
In vivo and in vitro irritation testing is important for evaluating the biological safety of medical devices. Here, the performance of positive reference materials for skin irritation testing was evaluated. Four reference standards, referred to as Y-series materials, were analyzed: a polyvinyl chloride (PVC) sheet spiked with 0 (Y-1), 1.0 (Y-2), 1.5 (Y-3), or 10 (Y-4) parts of Genapol X-080 per 100 parts of PVC by weight. Y-1, Y-2, and Y-3 did not induce skin irritation responses in an in vitro reconstructed human epidermis (RhE) tissue model, as measured by tissue viability or interleukin-1α release, or in an in vivo intracutaneous response test using rabbits. In contrast, Y-4 extracts prepared with saline or sesame oil at 37°C and 50°C clearly elicited positive irritation responses, including reduced viability (< 50%) and significantly higher interleukin-1α release compared with the solvent alone group, in the RhE tissue model and an intracutaneous response test, where substantial necrosis was observed by histopathology. The positive skin irritation responses induced in vitro under various extraction conditions, as well as those elicited in vivo, indicate that Y-4 is an effective extractable positive control material for in vivo and in vitro skin irritation tests of medical devices. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 Wiley Periodicals, Inc.
Ishihara, Tomoko; Yamashita, Haruhiro; Sakurai, Takanobu; Morita, Junya; Sakamoto, Kouji; Ishii, Aiko; Sasaki, Minoru
2017-10-01
Patchy thickening and reddish discoloration of active hair growth areas of skin in rabbits are occasionally found, and this gross feature could affect precise evaluation when conducting a dermal irritation test. Since little is known about the mechanism of this phenomenon, we examined the dorsal skin of New Zealand White rabbits morphologically and immunohistochemically in order to identify the possible mechanism responsible for developing these skin changes in relation to the hair cycle. Skin samples from 4 rabbits were divided into three groups (5 samples/group) based on their macroscopic characteristics: a thickened skin, erythematous skin, and smooth skin group. Histomorphological examination revealed that the percentage of hair follicles in the anagen phase, hair follicle length, hair follicle area, and proliferating cell nuclear antigen-positive cells in the hair follicles were greater in the thickened skin and erythematous skin groups than in the smooth skin group. Unlike mice and rats, the dermis was nearly adjacent to the muscular layer with a thin hypodermis, and the whole lengths of hair follicles in the anagen phase were located in the dermis in the rabbit skin. These results suggest that large hair follicles in the anagen phase compressed the surrounding dermis; therefore, the skin was grossly raised and showed thickening. A higher number of CD31-positive blood vessels, suggesting the occurrence of angiogenesis, was observed around the hair follicles in the erythematous skin group, and they seemed to affect the reddish discoloration of skin noted grossly.
Acute dermal toxicity of guanidine hydrochloride in rabbits. Report for 18 May-1 August 1984
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hiatt, G.F.; Sanso, S.K.; Korte, D.W.
1989-12-01
The acute dermal toxicity of guanidine hydrochloride was evaluated in five male and five female New Zealand White rabbits. Guanidine hydrochloride (2 g/kg) was applied topically to the clipped dorsal skin surface for 24 hours. No compound-related deaths or clinical signs were observed; however, guanidine hydrochloride did produce dermal irritation, necrosis, and eschar formation under conditions of the study.
Pinsuwan, Sirirat; Amnuaikit, Thanaporn; Ungphaiboon, Suwipa; Itharat, Arunporn
2010-12-01
Hibiscus sabdariffa Linn, or Roselle, is a medicinal plant used extensively in traditional Thai medicine since ancient times. The extracts of Roselle calyces possess antioxidant activity and have potential for development as active ingredients in cosmetic products. However the limitations of using Roselle extracts in cosmetics are its low skin permeation and dermal irritation. Liposome technology is an obvious approach that might overcome these problems. Liposome formulations of standardized Roselle extracts were developed with various lipid components. The formulation showing the highest entrapment efficiency was selected for stability, skin permeation and dermal irritability studies. The liposome formulation with the highest entrapment efficiency (83%) and smalôlest particle size (332 mm) was formulated with phosphatidylcholine from soybean (SPC): Tween 80: deoxycholic acid (DA); 84:16:2.5 weight ratio, total lipid of 200 g/mL and 10% w/v Roselle extract in final liposomal preparation. This liposome formulation was found to be stable after storage at 4 degrees C, protected from light, for 2 months. The in vitro skin permeation studies, using freshly excised pig skin and modified Franz-diffusion cells, showed that the liposome formulation was able to considerably increased the rate of permeation of active compounds in Roselle extracts compared to the Roselle extract solution. The in vivo dermal irritability testing on rabbit skin showed that the liposome formulation dramatically decreased skin irritability compared to the unformulated extract. These results showed that the liposomes containing Roselle extracts had good stability, high entrapment efficacy, increased skin permeation and low skin irritation.
Donahue, D A; Kaufman, L E; Avalos, J; Simion, F A; Cerven, D R
2011-03-01
The Chorioallantoic Membrane Vascular Assay (CAMVA) and Bovine Corneal Opacity and Permeability (BCOP) test are widely used to predict ocular irritation potential for consumer-use products. These in vitro assays do not require live animals, produce reliable predictive data for defined applicability domains compared to the Draize rabbit eye test, and are rapid and inexpensive. Data from 304 CAMVA and/or BCOP studies (319 formulations) were surveyed to determine the feasibility of predicting ocular irritation potential for various formulations. Hair shampoos, skin cleansers, and ethanol-based hair styling sprays were repeatedly predicted to be ocular irritants (accuracy rate=0.90-1.00), with skin cleanser and hair shampoo irritation largely dependent on surfactant species and concentration. Conversely, skin lotions/moisturizers and hair styling gels/lotions were repeatedly predicted to be non-irritants (accuracy rate=0.92 and 0.82, respectively). For hair shampoos, ethanol-based hair stylers, skin cleansers, and skin lotions/moisturizers, future ocular irritation testing (i.e., CAMVA/BCOP) can be nearly eliminated if new formulations are systematically compared to those previously tested using a defined decision tree. For other tested product categories, new formulations should continue to be evaluated in CAMVA/BCOP for ocular irritation potential because either the historical data exhibit significant variability (hair conditioners and mousses) or the historical sample size is too small to permit definitive conclusions (deodorants, make-up removers, massage oils, facial masks, body sprays, and other hair styling products). All decision tree conclusions should be made within a conservative weight-of-evidence context, considering the reported limitations of the BCOP test for alcohols, ketones, and solids. Copyright © 2010 Elsevier Ltd. All rights reserved.
TOXICOLOGIC STUDIES ON POLYPHENYL COMPOUNDS USED AS ATOMIC REACTOR MODERATOR-COOLANTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haley, T.J.; Detrick, L.E.; Komesu, N.
1959-09-01
A study has been made of certain aspects of the toxicology of organic polyphenyl compounds proposed for use as moderator-coolants in atomic reactors. Only monoisopropylbiphenyl, irradiated monoisopropylbiphenyl, and terphenyl mixtures (OMRE) were irritating to the conjunctiva in rabbits and oniy the unirradiated moderator-coolants caused skin irritation in rabbits. Both the moderators and their components were highly damaging to guinea pig skin following intracutaneous injection. All the polyphenyl compounds except irradiated monoisopropylbiphenyl produced sensitization and chemical necrosis. The latter produced only necrosis. Monoisopropylbiphenyl and o- and m-terphenyl were the only polyphenyls that caused death after inhalation, although all of the compoundsmore » produced some of the following symptoms: nasal congestion with rhinitis, lachrymation, labored respiration, and erythema of the ears and paws. The following histopathologic changes were also observed: acute tracheal necrosis, acute tracheobronchitis, pulmonary edema, bronchopneumonia, atelectasis, and petechial hemorrhages. All such toxic effects can be prevented by protective clothing and respirators. (auth)« less
Toxic Hazards Evaluation of Five Atmospheric Pollutants from Army Ammunition Plants
1977-06-01
administration of the compound led to severe pulmonary irritation similar to that caused by nitrogen dioxide (NO 2 ) Section II Simultaneous, 2-week... caused by the compound. Skin absorption toxicity was determined using female New Zealand albino rabbits. All’rabbits were clipped as closely as possible...those caused by nitrite intoxication under the premise that all NO 2 groups in TNM are converted to nitrite.’ Animals acutely exposed to TNM by the
Health-hazard evaluation report HETA 85-441-1765, New Boston Coke Corporation, New Boston, Ohio
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Malley, M.A.
1986-12-01
In response to a request from the Industrial Commission of Ohio, worker complaints of skin disease at the New Boston Coke Corporation, New Boston, Ohio were investigated. The request was based on seven reports of dermatitis thought to be associated with steam exposure during coke quenching. Quench water had a pH of 8.85 and contained phenol, ammonia, calcium-oxide, and suspended particulates (82% organic compounds); no irritant threshold levels were found for these compounds. Skin tests in rabbits showed a minimal irritant capacity for quench water. Medical records did not reveal the origin of dermatitis. Active skin lesions were characterized asmore » nummular eczema or atopic dermatitis, which were not thought to be of occupational origin. The author concludes that coke-quenching steam does not pose a skin hazard, but certain work activities may aggravate existing skin conditions. Recommendations include elimination of abrasive cleansing agents, use of skin moisturizers after washing, and prompt medical evaluation of skin complaints.« less
Safety and toxicological evaluation of a novel anti-obesity formulation LI85008F in animals.
Krishnaraju, A V; Sundararaju, D; Srinivas, P; Rao, C V; Sengupta, K; Trimurtulu, G
2010-02-01
LI85008F is a novel synergistic composition of Moringa oleifera, Murraya koenigi, and Curcuma longa. These herbs are well recognized and widely used in ayurvedic system of medicine for treating a variety of diseases and are also have been used for culinary purposes for thousands of years. LI85008F inhibits preadipocyte differentiation and potentiates lipid breakdown in mature adipocytes. In diet-induced obese rats, LI85008F significantly reduced weight gain and improved serum adiponectin levels. These findings motivated the authors to determine the broad-spectrum safety of LI85008F. Acute oral toxicity, acute dermal toxicity, primary skin irritation, primary eye irritation, and dose-dependent 28-day sub-acute toxicity studies were conducted. The acute oral LD50 of LI85008F was greater than 5000 mg/kg in female SD rats and no changes in body weight or adverse effects were observed following necropsy. Acute dermal LD50 of LI85008F was greater than 2000 mg/kg. LI85008F was classified as non-irritating to skin in a primary dermal irritation study conducted using New Zealand Albino rabbits. LI85008F caused minimal irritation to eyes in a primary eye irritation test conducted on New Zealand Albino rabbits. A dose-dependent 28-day sub-acute toxicity study demonstrated no significant changes in selected organ weights. Evaluations on hematology, clinical chemistry, and histopathology did not show any significant adverse changes. The NOAEL of LI85008F was found to be greater than 2500 mg/kg body weight. These results demonstrate the broad spectrum safety of LI85008F in animal models.
Needle-free injection of insulin powder: delivery efficiency and skin irritation assessment.
Li, Chun-yu; Wang, Zhe-wei; Tu, Can; Wang, Jia-bo; Jiang, Bing-qian; Li, Qi; Zeng, Ling-na; Ma, Zhi-jie; Zhang, Ping; Zhao, Yan-ling; Zhang, Ya-ming; Yan, Dan; Tan, Rui; Xiao, Xiao-he
2014-10-01
Insulin is widely used in treating diabetes, but still needs to be administered by needle injection. This study investigated a new needle-free approach for insulin delivery. A portable powder needleless injection (PNI) device with an automatic mechanical unit was designed. Its efficiency in delivering insulin was evaluated in alloxan-induced diabetic rabbits. The skin irritation caused by the device was investigated and the results were analyzed in relation to aerodynamic parameters. Inorganic salt-carried insulin powders had hypoglycemic effects, while raw insulin powders were not effective when delivered by PNI, indicating that salt carriers play an important role in the delivery of insulin via PNI. The relative delivery efficiency of phosphate-carried insulin powder using the PNI device was 72.25%. A safety assessment test showed that three key factors (gas pressure, cylinder volume, and nozzle distance) were related to the amount of skin irritation caused by the PNI device. Optimized injection conditions caused minimal skin lesions and are safe to use in practice. The results suggest that PNI has promising prospects as a novel technology for delivering insulin and other biological drugs.
Needle-free injection of insulin powder: delivery efficiency and skin irritation assessment*
Li, Chun-yu; Wang, Zhe-wei; Tu, Can; Wang, Jia-bo; Jiang, Bing-qian; Li, Qi; Zeng, Ling-na; Ma, Zhi-jie; Zhang, Ping; Zhao, Yan-ling; Zhang, Ya-ming; Yan, Dan; Tan, Rui; Xiao, Xiao-he
2014-01-01
Insulin is widely used in treating diabetes, but still needs to be administered by needle injection. This study investigated a new needle-free approach for insulin delivery. A portable powder needleless injection (PNI) device with an automatic mechanical unit was designed. Its efficiency in delivering insulin was evaluated in alloxan-induced diabetic rabbits. The skin irritation caused by the device was investigated and the results were analyzed in relation to aerodynamic parameters. Inorganic salt-carried insulin powders had hypoglycemic effects, while raw insulin powders were not effective when delivered by PNI, indicating that salt carriers play an important role in the delivery of insulin via PNI. The relative delivery efficiency of phosphate-carried insulin powder using the PNI device was 72.25%. A safety assessment test showed that three key factors (gas pressure, cylinder volume, and nozzle distance) were related to the amount of skin irritation caused by the PNI device. Optimized injection conditions caused minimal skin lesions and are safe to use in practice. The results suggest that PNI has promising prospects as a novel technology for delivering insulin and other biological drugs. PMID:25294378
Final report on the safety assessment of Triethylene Glycol and PEG-4.
2006-01-01
Triethylene Glycol and PEG-4 (polyethylene glycol) are polymers of ethylene oxide alcohol. Triethylene Glycol is a specific three-unit chain, whereas PEG-4 is a polymer with an average of four units, but may contain polymers ranging from two to eight ethylene oxide units. In the same manner, other PEG compounds, e.g., PEG-6, are mixtures and likely contain some Triethylene Glycol and PEG-4. Triethylene Glycol is a fragrance ingredient and viscosity decreasing agent in cosmetic formulations, with a maximum concentration of use of 0.08% in skin-cleansing products. Following oral doses, Triethylene Glycol and its metabolites are excreted primarily in urine, with small amounts released in feces and expired air. With oral LD50 values in rodents from 15 to 22 g/kg, this compound has little acute toxicity. Rats given short term oral doses of 3% in water showed no signs of toxicity, whereas all rats given 10% died by the 12th day of exposure. At levels up to 1 g/m3, rats exposed to aerosolized Triethylene Glycol for 6 h per day for 9 days showed no signs of toxicity. Rats fed a diet containing 4% Triethylene Glycol for 2 years showed no signs of toxicity. There were no treatment-related effects on rats exposed to supersaturated Triethylene Glycol vapor for 13 months nor in rats that consumed 0.533 cc Triethylene Glycol per day in drinking water for 13 months. Triethylene Glycol was not irritating to the skin of rabbits and produced only minimal injury to the eye. In reproductive and developmental toxicity studies in rats and mice, Triethylene Glycol did not produce biologically significant embryotoxicity or teratogenicity. However, some maternal toxicity was seen in dams given 10 ml/kg/day during gestation. Triethylene Glycol was not mutagenic or genotoxic in Ames-type assays, the Chinese hamster ovary mutation assay, and the sister chromatid exchange assays. PEG-4 is a humectant and solvent in cosmetic products, with a maximum concentration of use of 20% in the "other manicuring preparations" product category. This ingredient, with an oral LD50 in rats of 32.77 g/kg, has low acute toxicity. Rats given up to 50,000 ppm PEG-4 in drinking water for 5 days showed no permanent signs of toxicity. Rats given daily oral doses up to 2 g/kg/day of PEG-4 for 33 days showed no signs of toxicity. Undiluted PEG-4 produced only minimal injury to the rabbit eye. PEG-4 was not mutagenic in Ames-type assays, did not induce chromosome aberration in an in vivo bone marrow assay, and was negative for genotoxicity in a dominant lethal assay using rats. Other PEG compounds, which have previously been reviewed by the Cosmetic Ingredient Review (CIR) Expert Panel, e.g., PEG-6, are mixtures that likely include Triethylene Glycol and PEG-4, so these data were also considered. PEG-6 and PEG-8 were not dermal irritants in several rabbit studies. PEG-2 Stearate had a potential for slight irritation in rabbits but was not a sensitizer in guinea pigs. PEG-2 Cocamine was a moderate irritant in rabbits, producing severe erythema. In one dermal study, PEG-2 Cocamine was determined to be corrosive to rabbit skin, causing eschar and necrosis. PEG-6 and PEG-8 caused little to no ocular irritation. PEG-8 was not mutagenic or genotoxic in a Chinese hamster ovary assay, a sister-chromatid exchange assay, and in an unscheduled DNA synthesis assay. In clinical studies on normal skin, PEG-6 and PEG-8 caused mild cases of immediate hypersensitivity; PEG-8 was not a sensitizer; PEG-2 Stearate was not an irritant, a sensitizer, or a photosensitizer; and PEG-6 Stearate was not an irritant or sensitizer. In damaged skin, cases of systemic toxicity and contact dermatitis in burn patients were attributed to a PEG-based topical ointment. The CIR Expert Panel acknowledged the lack of dermal sensitization data for Triethylene Glycol and dermal irritation and sensitization data for PEG-4. That PEG-6, PEG-8, and PEG-2 Stearate were not irritants or sensitizers suggested that Triethylene Glycol and PEG-4 also would not be irritants or sensitizers, and the absence of any reported reactions in the case literature and the professional experience of the Expert Panel further supported the absence of any significant sensitization potential. The need for additional data to demonstrate the safety of PEGs Cocamine was related to the Cocamine moiety and is not relevant here. The Panel reminded formulators of cosmetic products that, as with other PEG compounds, Triethylene Glycol and PEG-4 should not be used on damaged skin because of cases of systemic toxicity and contact dermatitis in burn patients have been attributed to a PEG-based topical ointment. Based on its consideration of the available information, the CIR Expert Panel concluded that Triethylene Glycol and PEG-4 are safe as cosmetic ingredients in the present practices and concentrations of use as described in this safety assessment.
Dhondt, Marijke M M; Adriaens, Els; Roey, Jens Van; Remon, Jean Paul
2005-08-01
The purpose of this study was to evaluate the local tolerance of vaginal gels (three gels containing dapivirine, the placebo gel, and Conceptrol) with the Slug Mucosal Irritation test and to compare the results with those of the rabbit vaginal irritation test. The irritation potential on the slug mucosa was assessed by the mucus production caused by a repeated treatment for 5 successive days. Additionally, membrane damage was estimated by the protein and enzyme release. By means of a classification prediction model the formulations were classified into four irritation classes. The effect of a 10-day intravaginal application of the gels on the rabbit vaginal and cervical mucosa was evaluated by means of macroscopic and microscopic examination. The placebo and dapivirine gels induced no irritation of the slug mucosa (low mucus production and protein release, no enzyme release) and no vaginal or cervical irritation in rabbits. Conceptrol caused severe irritation of the slug mucosa (increased mucus production, protein release, and enzyme release) and irritation of the rabbit vagina and cervix. The results obtained with the Slug Mucosal Irritation test were comparable to those of the rabbit vaginal irritation test.
Acute toxicity and primary irritancy of alkylalkanolamines.
Ballantyne, B; Leung, H W
1996-12-01
The acute handling hazards of several alkylalkanolamines were determined by investigating their potential acute toxicity and primary irritancy. Materials studied were N-methylethanolamine (MEA), N, N, -dimethylethanolamine (DMEA), N, N, -dimethylisopropanolamine (DMIPA), N-methyldiethanolamine (MDEA), and tertbutyldiethanolamine (BDEA). All these alkylalkanolamines were of comparable acute peroral toxicity in the rat (LD50 range 1.48-2.83 ml/kg). By 24 h occluded epicutaneous contact in the rabbit, MEA, DMEA and DMIPA were of moderate acute percutaneous toxicity (LD50 range 1.13-2.0 ml/kg), MDEA was of slight acute percutaneous toxicity (LD50 male 9.85 ml/kg, female 10.90 ml/kg), and BDEA of intermediate toxicity (LD50 6.4 ml/kg). Due to differences in vapor pressure the acute vapor exposure toxicity of the alkylalkanolamines to rats varied; MEA, MDEA and BDEA were of a low order of acute toxicity, and DMIPA was moderately toxic with an LT50 of 3.2 h for a saturated vapor atmosphere exposure. A 4 h-LC50 (rat combined sex) of 1461 ppm was determined for DMEA. All alkylalkanolamines studied, except MDEA, were moderately to markedly irritating and caused variable degrees of skin corrosivity; MDEA caused only transient minor skin irritation. In accord with the skin irritancy results, the eye irritancy from 0.005 ml MEA, DMEA, DMIPA and BDEA was severe, and that from MDEA was slight. Exposure to these compounds has implications for occupational health procedures.
Acute dermal toxicity and sensitization studies of novel nano-enhanced UV absorbers.
Piasecka-Zelga, Joanna; Zelga, Piotr; Górnicz, Magdalena; Strzelczyk, Paweł; Sójka-Ledakowicz, Jadwiga
2015-01-01
Many employees working outside are exposed to the harmful effects of UV radiation. A growing problem is also sensitization to textile materials and allergic reactions to active compounds. Groups of inorganic UV blockers with nanoparticles may provide superior properties over organic UV absorbers with relatively less potential of provoking dermatitis. To assess acute dermal irritation and sensitization of nano UV absorbers. Five UV absorbers with nano-sized particles (Z11, TiO2 - SiO2 [TDPK], TK44, TK11, A8G) and 2 vehicles (paste-based on 10% PEG, and dispersion with 1% HEC) were tested. Acute dermal irritation was tested using group of 3 rabbits for each absorber. The sensitization study was carried out on groups of 15 guinea pigs for each tested textile with a UV absorber showing an Ultraviolet Protection Factor (UPF)>40. This research was designed according to OECD Test Guideline No. 404 and 406, and 21 rabbits and 60 guinea pigs were used in the study. In acute dermal irritation, Z11 and A8G modifiers and the analyzed paste gave results of 0.047 to 0.33 which classifies them as barely perceptible irritants, whereas the other analyzed modifiers and dispersion gave results of 0.00 and were classified as nonirritating. Only the textile with TK 11 did not have UPF>40. The analyzed barrier materials were classified as nonsenitizers (TDPK, A8G) or mild sensitizers (TK44, Z11). None of the analyzed materials or modifiers induced major skin reactions in animals. Therefore, they present low risk of provoking skin reactions in humans.
2014-12-24
toxlet.2011.04.007 Rogers JV, Choi YW, Kiser RC et al (2004) Microarray analysis of gene expression in murine skin exposed to sulfur mustard. J Bio...Chemotactic factors released in culture by intact developing and healing skin lesions produced in rabbits by the irritant sulfur mustard. Inflam- mation 21(2...Project ID Number CBM.CUTOC.04.10. RC 00114. ABSTRACT See reprint. 15. SUBJECT TERMS sulfur mustard, cutaneous injury, siRNA, high-throughput screening
Yoon, Weon-Jong; Ham, Young Min; Yoo, Byoung-Sam; Moon, Ji-Young; Koh, Jaesook; Hyun, Chang-Gu
2009-04-01
We elucidated the pharmacological and biological effects of Oenothera laciniata extracts on the production of inflammatory mediators in macrophages. The CH(2)Cl(2) fraction of O. laciniata extract effectively inhibited LPS-induced NO, PGE(2), and proinflammatory cytokine production in RAW264.7 cells. These inhibitory effects of the CH(2)Cl(2) fraction of O. laciniata were accompanied by decreases in the expression of iNOS and COX-2 proteins and iNOS, COX-2, TNF-alpha, IL-1beta, and IL-6 mRNA. Asiatic acid and quercetin were present in the HPLC fingerprint of the O. laciniata extract. We tested the potential application of O. laciniata extract as a cosmetic material by performing primary skin irritation tests. In New Zealand white rabbits, primary irritation tests revealed that application of O. laciniata extracts (1%) did not induce erythema or edema formation. Human skin primary irritation tests were performed on the normal skin (upper back) of 30 volunteers to determine if any material in O. laciniata extracts had irritation or sensitization potential. In these assays, O. laciniata extracts did not induce any adverse reactions. Based on these results, we suggest that O. laciniata extracts be considered possible anti-inflammatory candidates for topical application.
Parra, Alexander; Clares, Beatriz; Rosselló, Ana; Garduño-Ramírez, María L; Abrego, Guadalupe; García, María L; Calpena, Ana C
2016-03-30
The purpose of this study was the development of poly(d,l-lactide-co-glycolide) acid (PLGA) nanoparticles (NPs) for the dermal delivery of carprofen (CP). The developed nanovehicle was then lyophilized using hydroxypropyl-β-cyclodextrin (HPβCD) as cryoprotectant. The ex vivo permeation profiles were evaluated using Franz diffusion cells using three different types of skin membranes: human, porcine and bovine. Furthermore, biomechanical properties of skin (trans-epidermal water loss and skin hydration) were tested. Finally, the in vivo skin irritation and the anti-inflammatory efficacy were also assayed. Results demonstrated the achievement of NPs 187.32 nm sized with homogeneous distribution, negatively charged surface (-23.39 mV) and high CP entrapment efficiency (75.38%). Permeation studies showed similar diffusion values between human and porcine skins and higher for bovine. No signs of skin irritation were observed in rabbits. Topically applied NPs significantly decreased in vivo inflammation compared to the reference drug in a TPA-induced mouse ear edema model. Thus, it was concluded that NPs containing CP may be a useful tool for the dermal treatment of local inflammation. Copyright © 2016 Elsevier B.V. All rights reserved.
Padol, Amol R.; Jayakumar, K.; Shridhar, N. B.; Narayana Swamy, H. D.; Narayana Swamy, M.; Mohan, K.
2011-01-01
Acute dermal toxicity study was conducted in rats. The parameters studied were body weight, serum biochemistry and gross pathology. The animals were also observed for clinical signs and mortality after the application of test film. The dermal irritation potential of silk protein film was examined using Draize test. In the initial test, three test patches were applied sequentially for 3 min, 1 and 4 hours, respectively, and skin reaction was graded. The irritant or negative response was confirmed using two additional animals, each with one patch, for an exposure period of 4 hours. The responses were scored at 1, 24, 48 and 72 hours after the patch removal. Skin sensitization study was conducted according to Buehler test in guinea pigs, in which on day 0, 7 and 14, the animals were exposed to test material for 6 hours (Induction phase) and on day 28, the animals were exposed for a period of 24 hours (Challenge phase). The skin was observed and recorded at 24 and 48 hours after the patch removal. In acute dermal toxicity study, the rats dermally treated with silk film did not show any abnormal clinical signs and the body weight, biochemical parameters and gross pathological observations were not significantly different from the control group. In acute dermal irritation study, the treated rabbits showed no signs of erythema, edema and eschar, and the scoring was given as “0” for all time points of observations according to Draize scoring system. In skin sensitization study, there were no skin reactions 24 and 48 hours after the removal of challenge patch, which was scored “0” based on Magnusson/Kligman grading scale. PMID:21430915
Wound healing efficacy of Jatyadi Taila: in vivo evaluation in rat using excision wound model.
Shailajan, Sunita; Menon, Sasikumar; Pednekar, Suhas; Singh, Ashish
2011-10-31
In traditional Indian medicinal treatise there are several Ayurvedic formulations mentioned which have been claimed as potential wound healing agents like Madhu Ghrita and Jatyadi Taila. Jatyadi Taila (JT) is a medicated oil formulation (Taila) popularly used in the treatment of various topical wounds. Though JT has its composition recorded in ancient Ayurvedic texts, there have been minimal attempts to standardize its use in the management of wound. The current work evaluates the wound healing efficacy of JT and also provides evidence of the dermal absorption kinetics of Karanjin from JT. JT was subjected to preliminary phytochemical evaluation. Therapeutically active marker components β-sitosterol, lupeol and karanjin were detected and separated using HPTLC. As a part of safety evaluation, skin irritation potential of JT was evaluated on rabbit skin. Excision wound model in rats were used to evaluate the wound healing efficacy of JT. Histopathological and biochemical evaluations of excised skin tissues at wound sites were carried out. The HPTLC method developed was also validated to evaluate the pharmacokinetics of Karanjin from JT after topical application on pinna of rabbit. Preliminary phytochemical evaluation of JT revealed presence of flavonoids, essential oils, tannins, glycosides, steroids and alkaloids while resins were found to be absent. HPTLC confirmed the presence of karanjin, lupeol and β-sitosterol in JT. JT was found to be non-irritant when applied to the skin of rabbits. Topical application of JT on excision wounds caused significantly faster reduction in wound area as compared to the application of modern topical formulation (Neosporin(®)) and untreated control wounds. Animals treated with JT showed significant increase in protein, hydroxyproline and hexosamine content in the granulation tissue when compared with the untreated controls. Wound healing potential of JT was found to be dose dependant. HPTLC method was successfully used to evaluate the pharmacokinetics of Karanjin after topical application of JT on rabbit pinna. Current work demonstrates a modern approach towards standardization of the use of traditional topical formulation JT. The results justify the traditional claim of JT for its use in the management of wounds. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Safriani, R.; Sugihartini, N.; Yuliani, S.
2017-11-01
Essential oil of Syzigium aromaticum has been formulated in O/W and W/O creams as anti-inflammatory dosage form. The purpose of this study was to evaluate the physical characteristic and irritation index of S. aromaticum essential oil in O/W and W/O creams. The creams were made by fusion method. The creams then were evaluated the physical characteristic including pH, viscosity, spreadability and adhesivity. The irritation index was obtained by irritation skin test in male rabbit. The results showed that the W/O and O/W creams have the value of pH: 6.3 and 6.27; spreadability: 3,18 and 4.17 cm2; adhesivity: 5.59 and 0.07 minutes; viscosity: 4.43 and 2.88 Pa.S, respectively. The irritation test showed that the control enhancer caused mild irritation in both of W/O and O/W creams. These findings indicated that type of cream might influence the physical characteristic and irritation index of S. aromaticum essential oil cream.
Dutok, Carlos M S; Berenguer-Rivas, Clara Azalea; Rodríguez-Leblanch, Elizabeth; Pérez-Jackson, Liliana; Chil-Nuñez, Idelsy; Escalona-Arranz, Julio César; Reyes-Tur, Bernardo; Queiroz, Margareth M C
2015-01-01
The common use of Pouteria mammosa (L.) Cronquist, "Mamey or Zapote," in food and ethnobotanic medicine shows its low or absent toxicity as fruit extracts prepared from seeds. However, it is essential to conduct security trials to scientifically support their use in drug therapy. This study evaluated the aqueous and hydroalcoholic extract (25%) Acute Oral Toxicity, obtained from the seeds of P. mammosa, in Sprague Dawley rats and dermal and eye irritability in New Zealand rabbits. The 404 and 405 acute dermal and eye irritation/corrosion guidelines were used, as well as the 423 Acute Oral Toxicity guideline, Acute Toxic Class Method of the Organization for Economic Cooperation and Development (OECD). The aqueous extract was located in the following category: not classified as toxic (CTA 5), while hydroalcoholic extract at 25% was classified as dangerous (CTA 4). Both extracts can be used without side reaction that irritates the skin which permitted classification as potentially not irritant. P. mammosa in the two extracts caused mild and reversible eye irritation, and it was classified as slightly irritating.
The acute toxicity evaluation of a low-temperature hydraulic fluid.
Kinkead, E R; Wolfe, R E; Bunger, S K; Leahy, H F
1992-03-01
A low-temperature version of MIL-H-83282 (LT 83282) is a candidate hydraulic fluid to be used as a replacement for the current low-temperature fluid used on Strategic Air Command aircraft. A single neat dose of 0.1 mL LT 83282 into New Zealand White (NZW) rabbit eyes resulted in slight conjunctival irritation for up to 24 hr after treatment in two of nine rabbits. Rinsing the eyes after treatment appeared beneficial. A single treatment of 0.5 mL neat LT 83282 to rabbit skin produced no irritation. A total of 40% of the guinea pigs receiving repeated dermal application of the fluid demonstrated a positive sensitization response. A single oral dose of 5 g LT 83282/kg body weight given to five male and five female Fischer 344 (F-344) rats and a single dermal application of 2 g LT 83282/kg body weight applied to five male and five female NZW rabbits resulted in no deaths. Inhalation exposures to aerosol concentrations of LT 83282 resulted in an LC50 of 2.13 and 1.50 mg/L for male and female F-344 rats, respectively. No clinical signs of acute delayed neurotoxicity were observed in hens twice dosed at limit levels (5 g/kg) and observed for 21 days.
Zhao, Ji-Hui; Zhang, Qi-Bo; Liu, Bao; Piao, Xiang-Hua; Yan, Yu-Lu; Hu, Xiao-Ge; Zhou, Kuan; Zhang, Yong-Tai; Feng, Nian-Ping
2017-01-01
Purpose To enhance the immunogenicity of the model subunit vaccine, ovalbumin (OVA) was combined with platycodin (PD), a saponin adjuvant. To reduce the toxicity of PD, OVA, and adjuvant were loaded together into liposomes before being incorporated into a dissolving microneedle array. Methods OVA- and PD-loaded liposomes (OVA-PD-Lipos) were prepared using the film dispersion method. Their uptake behavior, toxicity to mouse bone marrow dendritic cells (BMDCs), and hemolytic activity to rabbit red blood cells (RBCs) were evaluated. The OVA-PD-Lipos were incorporated into a dissolving microneedle array. The chemical stability of OVA and the physical stability of OVA-PD-Lipos in microneedle arrays were investigated. The immune response of Institute of Cancer Research mice and potential skin irritation reaction of rabbits to OVA-PD-Lipos-MNs were evaluated. Results The uptake of OVA by mouse BMDCs was greatly enhanced when OVA was prepared as OVA-PD-Lipos, and in this form, the toxicity of PD was dramatically reduced. OVA was chemically stable as OVA-PD-Lipos, when OVA-PD-Lipos was incorporated into a dissolving microneedle array. Institute of Cancer Research mice treated with OVA-PD-Lipos-MNs showed a significantly enhanced immune response. PD combined with OVA elicited a balanced Th1 and Th2 humoral immune response in mice, with minimal irritation in rabbit skin. Conclusion The dissolving microneedle array-based system is a promising delivery vehicle for subunit vaccine and its adjuvant. PMID:28740383
BMY 30047: A novel topically active retinoid with low local and systemic toxicity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nair, X.; Quigley, J.; Tramposch, K.M.
In the treatment of various dermatological disorders, topically applied retinoids have potential therapeutic use with the advantage of improved localized activity and lower toxicity over systemically administered retinoids. However, most retinoids cause a significant degree of local irritation. In the present study, the ability to produce local activity with low local irritation potential was evaluated with a novel retinoic acid derivative. BMY 30047 (11-cis, 13-cis-12-hydroxymethylretinoic acid delta-lactone) is one of a series of retinoic acid derivatives in which the carboxyl function of the polar end was modified with the aim of achieving reduced local irritation and systemic toxicity while retainingmore » the local therapeutic effect. BMY 30047 was evaluated and compared with all-trans retinoic acid for topical retinoid activity in several preclinical assay systems, including the utricle reduction assay in rhino mice, 12-o-tetradecanoylphorbol 13-acetate ester-stimulated ornithine decarboxylase induction in hairless mice and the UV light-induced photodamaged skin model in hairless mice. BMY 30047 was assessed for retinoid-type side effects by evaluating the skin irritation potential in rabbits after repeated topical application, and hypervitaminosis A-inducing potential in mice after i.p. injection. BMY 30047 demonstrated significant topical retinoid activity in several in vivo models with less skin irritation potential relative to the most used clinical concentrations of all-trans retinoic acid. BMY 30047 also showed very little systemic activity and did not produce any evidence of hypervitaminosis A syndrome at systemic doses 20 times greater than the no-effect dose of all-trans retinoic acid.« less
Evaluation of Barrier Skin Cream Effectiveness Against JP-8 Jet Fuel Absorption and Irritation
2009-04-01
quantify the colorimeter measurements. This system uses spectral chromaticity coordinates and corresponding color- matching functions based on...in the caudal thigh or lumbar muscles and the rabbit was monitored throughout the procedure. Once anesthetized, a baseline visual and colorimeter ...Visual Scoring Technique All barrier creams were scored in 3 ways; by visual scoring described in the Draize method, by colorimeter , and by
Bora, Nilutpal Sharma; Pathak, Manash Pratim; Mandal, Santa; Mazumder, Bhaskar; Policegoudra, Rudragoud; Raju, Pakalapati Srinivas; Chattopadhyay, Pronobesh
2017-10-01
Ultraviolet (UV) radiation exposure has been known to cause irreparable damages to human skin. The daunting risk of UV radiation exposure faced by military personnel led to the development of a sunscreen formulation which has superior sun protection factor combined with the ability to counteract reactive oxygen species. The present work deals with the preclinical safety evaluation of the sunscreen formulation comprising of four US FDA approved UV filters; namely avobenzone, octinoxate, oxybenzone, titanium dioxide along with melatonin and pumpkin seed oil, via OECD protocols of assessing acute oral and dermal toxicity; skin sensitizing; skin irritating; ocular irritating and genotoxic potential. Both oral and dermal LD 50 values were found to be ˃2000 mg/kg body weight in adult Wistar albino rats using acute dermal and oral toxicity tests. The sunscreen formulation was found to be non-sensitizing to the skin of guinea pigs and non-irritating to both skin and eyes of rabbits. The sunscreen formulation was also found to be non-mutagenic which was affirmed by a battery of genotoxicity and muagenicity assays. The results obtained from this preclinical study indicated that the sunscreen formulation is non toxic and safe in animal models. This study along with additional preclinical evaluations may serve as a basis for considering the formulation as a potential candidate for further trials to establish its efficacy, tolerability and applicability. Copyright © 2017 Elsevier Inc. All rights reserved.
Safety of a Novel Botanical Extract Formula for Ameliorating Allergic rhinitis. Part II.
Amit, A; Joshua, A J; Bagchi, M; Bagchi, D
2005-01-01
Abstract Each year more than 50 million Americans suffer from allergic rhinitis, which is a state of hypersensitivity or hyperimmunity. Basically, allergic rhinitis is symptomatically recognized as the inflammation and irritation of the nasal mucosal membranes; sneezing; stuffy/runny nose; nasal congestion; and itchy; watery, and swollen eyes; and defined as a state of hypersensitivity/ hyperimmunity caused by exposure to a particular allergen (antigen) that results in increased reactivity upon subsequent exposure. A novel polyherbal formulation (Aller-7/NR-A2) was developed for the treatment of allergic rhinitis using a unique combination of extracts from seven medicinal plants, including Phyllanthus emblica, Terminalia chebula, Terminalia bellerica, Albizia lebbeck, Piper nigrum, Zingiber officinale, and Piper longum. Earlier studies in our laboratories have demonstrated potent antihistaminic, anti-inflammatory, antispasmodic, antioxidant, and mast-cell stabilization activities of Aller-7 in addition to its efficacy in a clinical setting. A series of preliminary toxicological evaluations were also conducted in the past, which demonstrated its safety. In this study, we have conducted further safety studies on Aller-7, including acute oral, acute dermal, acute dermal irritation, eye irritation, and 90-day repeated dose toxicity studies. Acute oral toxicity of Aller-7 was found to be greater than 5,000 mg/kg body weight in both male and female rats and no mortality or toxicity was observed at this dose, while the acute dermal toxicity was found to be greater than 2,000 mg/kg body weight. In the acute dermal irritation study, the skin irritancy index was found to be 0.0, which classifies Aller-7 as a nonirritant to rabbit skin. In the acute eye irritation study, Aller-7 was found to have minimal irritancy to eyes of rabbits. In the repeated-dose 90-day oral toxicity study, Aller-7 was administered at dose levels of 100, 300, and 1,000 mg/kg rat body weight for 90 consecutive days by oral gavage. Aller-7 did not induce any significant change in the hematological parameters. No ocular abnormalities were observed. Some minor histopathological changes were observed, but did not reveal any significant treatment-related histopathological changes. The above findings revealed that the no observed adverse effect level (NOAEL) of Aller-7 is greater than 1,000 mg/kg body weight. Taken together, these studies demonstrate the broad spectrum safety of Aller-7.
Transdermal Drug Delivery System. Stage 1. Volume 3
1987-12-30
lauryl sulfate (0.33%) docusate sodium (0.35%) and potassium laurate (1%) were tested and found not irritating to rabbit skin. Formulations of 50% S...hydroxypropylmethylcellulose (HPMC) gel containing either 0.198% sodium lauryl sulfate or 0.21% docusate sodium . A HPMC gel containing 50% S-26741...formulation excipients and combinations of both. S-26741 (neat chemical) and a 50% S-26741/0.33% sodium lauryl sulfate formulation were tested using the
Reno, Frederick E; Edwards, C Nicholas; Bendix Jensen, Morten; Török-Bathó, Magdolna; Esdaile, David J; Piché, Claude; Triest, Myriam; Carballo, Dolorès
2016-09-01
The intranasal route is a promising route of administration for several emergency rescue drugs including naloxone and glucagon. Glucagon nasal powder (GNP) is a novel, needle-free delivery system for intranasal administration of glucagon for the treatment of severe hypoglycemia, an infrequent but serious complication of insulin use in patients with diabetes. The GNP delivery device is a compact, highly portable, single-use nasal powder dosing device constructed of polypropylene that allows for simple, single-step administration. To evaluate the toxicological profile of the polypropylene resin used in the actuator part of the delivery device that will contact skin and nasal mucosal membranes of the patient, we performed an in vitro cytotoxicity study, a skin sensitization study and an irritation (intracutaneous reactivity) study in animal models. Extracts of the actuator of the GNP device were generated from HAM F12 medium with 10% fetal bovine serum, 0.9% sodium chloride (NaCl) or sesame oil. The in vitro cytotoxicity test was performed in cultured L929 mouse fibroblasts. Skin sensitization analysis was performed in 10 guinea pigs according to the Magnusson-Kligman method, using a maximization method with Freund's Complete Adjuvant. Irritation following intracutaneous/intradermal treatment with device extracts (NaCl and sesame oil extractants) was assessed in three New Zealand White rabbits. In vitro cytotoxicity test: Both undiluted and diluted extract showed no toxicity (i.e. no abnormal morphology, cell death or cell lysis) toward L929 fibroblasts (cytotoxicity grade 0). Sensitization test in guinea pigs: Challenge with device extracts did not evoke positive responses in test animals previously induced with device extracts. The net response value represented an incidence rate of 0% and a net dermal irritation score value of 0.00. Irritation (intracutaneous/intradermal) test in New Zealand White rabbits: Device extracts and corresponding vehicle controls caused similar irritation reactions. The difference between the mean scores for the device extracts and the corresponding vehicle controls was less than 1.0. Extracts of the polypropylene resin of the GNP delivery device are not cytotoxic, do not result in dermal sensitization and do not cause irritation when applied topically or intracutaneously. Given the infrequent use and very short duration of exposure to the nasal mucosa during administration of GNP, the polypropylene resin of the GNP device actuator will likely not cause adverse dermal sensitization effects or irritation effects in humans and can, therefore, be considered for use as a delivery device in clinical trials assessing the efficacy and safety of GNP for the treatment of insulin-using patients experiencing episodes of severe hypoglycemia.
Enhancement of transdermal delivery of ibuprofen using microemulsion vehicle.
Hu, Liandong; Hu, Qiaofeng; Yang, Jianxue
2014-10-01
The objective of this study was to find a stable microemulsion vehicle for transdermal delivery of ibuprofen to improve the skin permeability. Microemulsion was prepared using different sorts of oils, surfactants and co-surfactants. Pseudo-ternary phase diagrams were used to evaluate the microemulsion domain. The effects of oleic acid and surfactant mixture on skin permeation of ibuprofen were evaluated with excised skins. The optimum formulation F3 consisting of 6% oleic acid, 30% Cremophor RH40/Transcutol P (2:1, w/w) and 59% water phase, showed a high permeation rate of 42.98 µg/cm(2)/hr. The mean droplet size of microemulsion was about 43 nm and no skin irritation signs were observed on the skin of rabbits. These results indicated that this novel microemulsion is a useful formulation for the transdermal delivery of ibuprofen.
Radiation prevulcanized natural rubber latex: Cytotoxicity and safety evaluation on animal
NASA Astrophysics Data System (ADS)
Keong, C. C.; Zin, W. M. Wan; Ibrahim, P.; Ibrahim, S.
2010-05-01
Radiation prevulcanized natural rubber latex (RVNRL) was claimed to be more user friendly than natural rubber latex prevulcanized by sulphur curing system. The absence of Type IV allergy inducing chemicals in RVNRL make it a suitable material for manufacturing of many kinds of latex products, especially those come into direct contact with users. This paper reveals and discusses the findings of cytotoxicity test and safety evaluation on animal for RVNRL. The test was done on RVNRL films prepared by coagulant dipping method and RVNRL dipped products produced by latex dipped product manufacturers. Cytotocixity test was carried out on mammalian cell culture American Type Culture Collection CCL 81, Vero. Results indicated that no cytotoxic effect from RVNRL films and products was found on the cell culture. Two animal studies, namely dermal sensitization study and primary skin irritation study, were done on gloves made from RVNRL. Albino white guinea pigs were used as test subjects in dermal sensitization study and results showed no sensitization induced by the application of test material in the guinea pigs. Primary skin irritation study was done on New Zealand white rabbits and results showed that the product tested was not corrosive and was not a primary irritant
Enhancement of transdermal delivery of ibuprofen using microemulsion vehicle
Hu, Liandong; Hu, Qiaofeng; Yang, Jianxue
2014-01-01
Objective(s): The objective of this study was to find a stable microemulsion vehicle for transdermal delivery of ibuprofen to improve the skin permeability. Materials and Methods: Microemulsion was prepared using different sorts of oils, surfactants and co-surfactants. Pseudo-ternary phase diagrams were used to evaluate the microemulsion domain. The effects of oleic acid and surfactant mixture on skin permeation of ibuprofen were evaluated with excised skins. Results: The optimum formulation F3 consisting of 6% oleic acid, 30% Cremophor RH40/Transcutol P (2:1, w/w) and 59% water phase, showed a high permeation rate of 42.98 µg/cm2/hr. The mean droplet size of microemulsion was about 43 nm and no skin irritation signs were observed on the skin of rabbits. Conclusion: These results indicated that this novel microemulsion is a useful formulation for the transdermal delivery of ibuprofen. PMID:25729544
2014-02-01
NA 5c. PROGRAM ELEMENT NUMBER 62202F 6. AUTHOR(S) Sterner, Teresa R.1; Hurley, Jonathon M.2; Edwards, James T.3; Shafer, Linda M.4; Mattie , David R... Mattie , D.R. 2014. Acute Dermal Irritation Study of Ten Jet Fuels in New Zealand White Rabbits: Comparison of Synthetic and Bio -Based Jet Fuels with...AFRL-RH-WP-TR-2014-0046 ACUTE DERMAL IRRITATION STUDY OF SIX JET FUELS IN NEW ZEALAND WHITE RABBITS: COMPARISON OF FOUR BIO -BASED JET FUELS
Elmore, Amy R
2005-01-01
Potassium Silicate, Sodium Metasilicate, and Sodium Silicate combine metal cations with silica to form inorganic salts used as corrosion inhibitors in cosmetics. Sodium Metasilicate also functions as a chelating agent and Sodium Silicate as a buffering and pH adjuster. Sodium Metasilicate is currently used in 168 formulations at concentrations ranging from 13% to 18%. Sodium Silicate is currently used in 24 formulations at concentrations ranging from 0.3% to 55%. Potassium Silicate and Sodium Silicate have been reported as being used in industrial cleaners and detergents. Sodium Metasilicate is a GRAS (generally regarded as safe) food ingredient. Aqueous solutions of Sodium Silicate species are a part of a chemical continuum of silicates based on an equilibrium of alkali, water, and silica. pH determines the solubility of silica and, together with concentration, determines the degree of polymerization. Sodium Silicate administered orally is readily absorbed from the alimentary canal and excreted in the urine. The toxicity of these silicates has been related to the molar ratio of SiO2/Na2O and the concentration being used. The Sodium Metasilicate acute oral LD50 ranged from 847 mg/kg in male rats to 1349.3 mg/kg in female rats and from 770 mg/kg in female mice to 820 mg/kg in male mice. Gross lesions of variable severity were found in the oral cavity, pharynx, esophagus, stomach, larynx, lungs, and kidneys of dogs receiving 0.25 g/kg or more of a commercial detergent containing Sodium Metasilicate; similar lesions were also seen in pigs administered the same detergent and dose. Male rats orally administered 464 mg/kg of a 20% solution containing either 2.0 or 2.4 to 1.0 ratio of sodium oxide showed no signs of toxicity, whereas doses of 1000 and 2150 mg/kg produced gasping, dypsnea, and acute depression. Dogs fed 2.4 g/kg/day of Sodium Silicate for 4 weeks had gross renal lesions but no impairment of renal function. Dermal irritation of Potassium Silicate, Sodium Metasilicate, and Sodium Silicate ranged from negligible to severe, depending on the species tested and the molar ratio and concentration tested. Sodium Metasilicate was negative in the local lymph node assay (LLNA), but a delayed-type hypersensitivity response was observed in mice. Potassium Silicate was nonirritating in two acute eye irritation studies in rabbits. Sodium Metasilicate (42.4% H2O) was corrosive to the rabbit eye. Sodium Silicate was a severe eye irritant in some eye irritation studies, but was irritating or nonirritating in others. A skin freshener containing Sodium Silicate was nonirritating. Sodium Metasilicate was nonmutagenic in bacterial cells. Rats given Sodium Silicate (600 and 1200 ppm of added silica) in the drinking water in reproductive studies produced a reduced number of offspring: to 67% of controls at 600 ppm and to 80% of controls at 1200 ppm. Three adult rats injected intratesticularly and subcutaneously with 0.8 mM/kg of Sodium Silicate showed no morphological changes in the testes and no effect on the residual spermatozoa in the ductus deferens. Sodium Metasilicate (37% in a detergent) mixed with water was a severe skin irritant when tested on intact and abraded human skin, but 6%, 7%, and 13% Sodium Silicate were negligible skin irritants to intact and abraded human skin. Sodium Silicate (10% of a 40% aqueous solution) was negative in a repeat-insult predictive patch test in humans. The same aqueous solution of Sodium Silicate was considered a mild irritant under normal use conditions in a study of cumulative irritant properties. The Cosmetic Ingredient Review (CIR) Expert Panel recognized the irritation potential of these ingredients, especially in leave-on products. However, because these ingredients have limited dermal absorption and Sodium Metasilicate is a GRAS direct food substance, the Panel deemed the ingredients safe for use in cosmetic products in the practices of use and concentration described in this safety assessment, when formulated to avoid irritation.
2005-01-01
Methacrylate ester monomers are used in as artificial nail builders in nail enhancement products. They undergo rapid polymerization to form a hard material on the nail that is then shaped. While Ethyl Methacrylate is the primary monomer used in nail enhancement products, other methacrylate esters are also used. This safety assessment addresses 22 other methacrylate esters reported by industry to be present in small percentages as artificial nail builders in cosmetic products. They function to speed up polymerization and/or form cross-links. Only Tetrahydrofurfuryl Methacrylate was reported to the FDA to be in current use. The polymerization rates of these methacrylate esters are within the same range as Ethyl Methacrylate. While data are not available on all of these methacrylate esters, the available data demonstrated little acute oral, dermal, or i.p. toxicity. In a 28-day inhalation study on rats, Butyl Methacrylate caused upper airway irritation; the NOAEL was 1801 mg/m3. In a 28-day oral toxicity study on rats, t-Butyl Methacrylate had a NOAEL of 20 mg/kg/day. Beagle dogs dosed with 0.2 to 2.0 g/kg/day of C12 to C18 methacrylate monomers for 13 weeks exhibited effects only in the highest dose group: weight loss, emesis, diarrhea, mucoid feces, or salivation were observed. Butyl Methacrylate (0.1 M) and Isobutyl Methacrylate (0.1 M) are mildly irritating to the rabbit eye. HEMA is corrosive when instilled in the rabbit eye, while PEG-4 Dimethacrylate and Trimethylolpropane Trimethacrylate are minimally irritating to the eye. Dermal irritation caused by methacrylates is documented in guinea pigs and rabbits. In guinea pigs, HEMA, Isopropylidenediphenyl Bisglycidyl Methacrylate, Lauryl Methacrylate, and Trimethylolpropane Trimethacrylate are strong sensitizers; Butyl Methacrylate, Cyclohexyl Methacrylate, Hexyl Methacrylate, and Urethane Methacrylate are moderate sensitizers; Hydroxypropyl Methacrylate is a weak sensitizer; and PEG-4 Dimethacrylate and Triethylene Glycol Dimethacrylate are not sensitizers. Ethylene Glycol Dimethacrylate was not a sensitizer in one guinea pig study, but was a strong sensitizer in another. There is cross-reactivity between various methacrylate esters in some sensitization tests. Inhaled Butyl Methacrylate, HEMA, Hydroxypropyl Methacrylate, and Trimethylolpropane Trimethacrylate can be developmental toxicants at high exposure levels (1000 mg/kg/day). None of the methacrylate ester monomers that were tested were shown to have any endocrine disrupting activity. These methacrylate esters are mostly non-mutagenic in bacterial test systems, but weak mutagenic responses were seen in mammalian cell test systems. Chronic dermal exposure of mice to PEG-4 Dimethacrylate (25 mg, 2 x weekly for 80 weeks) or Trimethylolpropane Trimethacrylate (25 mg, 2 x weekly for 80 weeks) did not result in increased incidence of skin or visceral tumors. The carcinogenicity of Triethylene Glycol Dimethacrylate (5, 25, or 50%) was assessed in a mouse skin painting study (50 microl for 5 days/week for 78 weeks), but was not carcinogenic at any dose level tested. The Expert Panel was concerned about the strong sensitization and crossor co-reactivity potential of the methacrylate esters reviewed in this report. However, data demonstrated the rates of polymerization of these Methacrylates were similar to that of Ethyl Methacrylate and there would be little monomer available exposure to the skin. In consideration of the animal toxicity data, the CIR Expert Panel decided that these methacrylate esters should be restricted to the nail and must not be in contact with the skin. Accordingly, these methacrylate esters are safe as used in nail enhancement products when skin contact is avoided.
Topical lavender oil for the treatment of recurrent aphthous ulceration.
Altaei, D Tagreed
2012-02-01
To determine the laboratory and clinical efficacy of lavender oil in the treatment of recurrent aphthous ulceration (RAU). This was a randomized double-blind, placebo-controlled study performed firstly to treat the induced ulcers by different methods in experimental animals (rabbits) treated with lavender oil or placebo. Clinical and histological healing was established by measuring the area of the ulcer and inflammation levels in each test group. Secondly, safety/toxicity; the median lethal dose (LD50) was studied in albino mice, and dermal irritation test was performed by primary irritation to the skin and measured by a patch-test technique on the intact skin of the albino rabbit. Thirdly, antibacterial effect; lavender oil was screened against bacteria obtained from swab specimen of human subjects' RAU using disc diffusion method. Fourthly, clinical study; 115 subjects (mean age 38 years, mean weight 75 kg) were divided into two groups of subjects topically treated with lavender oil or placebo. The clinical efficacy was assessed by inflammation level, erythema, edema, ulcer duration, ulcer size, mean area under the curve of ulcer area, healing time, and associated pain intensity and reduction. Animals treated with lavender oil showed a significant ulcer size reduction, increased rate of mucosal repair, and healing within 3 days of treatment compared to baseline and placebo groups [2-3 days (90%), 4 days (10%)] (P=0.001). The intraperitoneal LD50 value in mice was 6.5 gm/kg; clinical dermal irritation test showed no sign of irritation in the tested products. Lavender oil showed a broad antibacterial activity against all tested strains; it exhibited significant inhibition on tested bacteria where the value of zone of inhibition ranged from 14.5-24 mm vs Streptomycin (25 microg/disc) 12-22 +/- 0.5 mm; MIC was > 6.4-36 mg/ml. RAU patients treated with lavender oil showed a significant reduction in inflammation level, ulcer size, healing time, from 2-4 days [2 days (40%), 3 days (50%), 4 days (10%)], and pain relief mostly from the first dose, compared to baseline and placebo. No side effects were reported.
Jang, Won-hee; Jung, Kyoung-mi; Yang, Hye-ri; Lee, Miri; Jung, Haeng-Sun; Lee, Su-Hyon; Park, Miyoung; Lim, Kyung-Min
2015-01-01
The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCETM which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCETM can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines. PMID:26157556
Song, Aihua; Su, Zhen; Li, Sanming; Han, Fei
2015-01-01
In order to assess the preliminary safety and effectiveness of nanostructured lipid carriers-based flurbiprofen gel (FP NLC-gel), the acute irritation test, in vivo pharmacodynamics evaluation and pharmacokinetic study were investigated after topical application. No dropsy and erythema were observed after continuous dosing 7 d of FP NLC-gel on the rabbit skin, and the xylene-induced ear drossy could be inhibited by FP NLC-gel at different dosages. The maximum concentration of FP in rats muscle was 2.03 μg/g and 1.55 μg/g after oral and topical administration, respectively. While the peak concentration in untreated muscle after topical administration was only 0.37 μg/mL. And at any time, following topical administration the mean muscle-plasma concentration ratio Cmuscle/CPlasma was obviously higher than that following oral administration. Results indicated that FP could directly penetrate into the subcutaneous muscle tissue from the administration site. Thus, the developed FP NLC-gel could be a safe and effective vehicle for topical delivery of FP.
Shen, Li-Na; Zhang, Yong-Tai; Wang, Qin; Xu, Ling; Feng, Nian-Ping
2014-01-01
The aims of the present study were to investigate the skin permeation and cellular uptake of a microemulsion (ME) containing total flavone of rhizoma arisaematis (TFRA), and to evaluate its effects on skin structure. Pseudo-ternary phase diagrams were constructed to evaluate ME regions with various surfactants and cosurfactants. Eight formulations of oil-in-water MEs were selected as vehicles, and in vitro skin-permeation experiments were performed to optimize the ME formulation and to evaluate its permeability, in comparison to that of an aqueous suspension. Laser scanning confocal microscopy and fluorescent-activated cell sorting were used to explore the cellular uptake of rhodamine 110-labeled ME in human epidermal keratinocytes (HaCaT) and human embryonic skin fibroblasts (CCC-ESF-1). The structure of stratum corneum treated with ME was observed using a scanning electron microscope. Furthermore, skin irritation was tested to evaluate the safety of ME. ME formulated with 4% ethyl oleate (weight/weight), 18% Cremophor EL® (weight/weight), and 18% Transcutol® P, with 1% Azone to enhance permeation, showed good skin permeability. ME-associated transdermal fluxes of schaftoside and isoschaftoside, two major effective constituents of TFRA, were 3.72-fold and 5.92-fold higher, respectively, than those achieved using aqueous suspensions. In contrast, in vitro studies revealed that uptake by HaCaT and CCC-ESF-1 cells was lower with ME than with an aqueous suspension. Stratum corneum loosening and shedding was observed in nude mouse skin treated with ME, although ME produced no observable skin irritation in rabbits. These findings indicated that ME enhanced transdermal TFRA delivery effectively and showed good biocompatibility with skin tissue. PMID:25092976
Adriaens, E; Verstraelen, S; Alépée, N; Kandarova, H; Drzewiecka, A; Gruszka, K; Guest, R; Willoughby, J A; Van Rompay, A R
2018-06-01
Assessment of acute eye irritation potential is part of the international regulatory requirements for safety testing of chemicals. In the last decades, many efforts have been made in the search for alternative methods to replace the regulatory in vivo Draize rabbit eye test (OECD TG 405). Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. The main objective of the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for serious eye damage and eye irritation assessment that can lead to complete replacement of OECD TG 405. A set of 80 reference chemicals (e.g. balanced by important driver of classification and physical state), was tested with seven test methods. Based on the results of this project, three different strategies were suggested. We have provided a standalone (EpiOcular ET-50), a two-tiered and three-tiered strategy, that can be used to distinguish between Cat 1 and Cat 2 chemicals and chemicals that do not require classification (No Cat). The two-tiered and three-tiered strategies use an RhCE test method (EpiOcular EIT or SkinEthic™ EIT) at the bottom (identification No Cat) in combination with the BCOP LLBO (two-tiered strategy) or BCOP OP-KIT and SMI (three-tiered strategy) at the top (identification Cat 1). For our proposed strategies, 71.1% - 82.9% Cat 1, 64.2% - 68.5% Cat 2 and ≥80% No Cat chemicals were correctly identified. Also, similar results were obtained for the Top-Down and Bottom-Up approach. Copyright © 2017 Elsevier Ltd. All rights reserved.
Final report on the safety assessment of ethoxyethanol and ethoxyethanol acetate.
Johnson, Wilbur
2002-01-01
Ethoxyethanol is an ether alcohol described as a solvent and viscosity-decreasing agent for use in cosmetics. Ethoxyethanol Acetate is the ester of Ethoxyethanol and acetic acid described as a solvent for use in cosmetics. Although these ingredients have been used in the past, neither ingredient is in current use. Ethoxyethanol is produced by reacting ethylene oxide with ethyl alcohol. Ethoxyethanol Acetate is produced via an esterification of Ethoxyethanol and acetic acid, acetic acid anhydride, or acetic chloride. Ethoxyethanol is metabolized to ethoxyacetaldehyde, which is further metabolized to ethoxyacetic acid, which is also a metabolite of Ethoxyethanol Acetate. Low to moderate acute inhalation toxicity is seen in animals studies. Acute oral toxicity studies in several species reported kidney damage, including extreme tubular degeneration. Kidney damage was also seen in acute dermal toxicity studies in rats and rabbits. Minor liver and kidney damage was also seen in short-term studies of rats injected subcutaneously with Ethoxyethanol, but was absent in dogs dosed intravenously. Mixed toxicity results were also seen in subchronic tests in mice and rats. Ethoxyethanol and Ethoxyethanol Acetate were mild to moderate eye irritants in rabbits; mild skin irritants in rabbits, and nonsensitizing in guinea pigs. Most genotoxicity tests were negative, but chromosome aberrations and sister-chromatid exchanges were among the positive results seen. Numerous reproductive and developmental toxicity studies, across several species, involving various routes of administration, indicate that Ethoxyethanol and Ethoxyethanol Acetate are reproductive toxicants and teratogens. Mild anemia was reported in individuals exposed occupationally to Ethoxyethanol, which resolved when the chemical was not used. Reproductive effects have been noted in males exposed occupationally to Ethoxyethanol. Although there are insufficient data to determine the potential carcinogenic effects of Ethoxyethanol or Ethoxyethanol Acetate, there is evidence that these chemicals are absorbed across human skin and that they are reproductive and developmental toxicants via dermal exposure. Therefore, these ingredients are unsafe for use in cosmetic formulations.
Enhancing blood donor skin disinfection using natural oils.
Alabdullatif, Meshari; Boujezza, Imen; Mekni, Mohamed; Taha, Mariam; Kumaran, Dilini; Yi, Qi-Long; Landoulsi, Ahmed; Ramirez-Arcos, Sandra
2017-12-01
Effective donor skin disinfection is essential in preventing bacterial contamination of blood components with skin flora bacteria like Staphylococcus epidermidis. Cell aggregates of S. epidermidis (biofilms) are found on the skin and are resistant to the commonly used donor skin disinfectants chlorhexidine-gluconate and isopropyl alcohol. It has been demonstrated that essential oils synergistically enhance the antibacterial activity of chlorhexidine-gluconate. The objective of this study was to test plant-extracted essential oils in combination with chlorhexidine-gluconate or chlorhexidine-gluconate plus isopropyl alcohol for their ability to eliminate S. epidermidis biofilms. The composition of oils extracted from Artemisia herba-alba, Lavandula multifida, Origanum marjoram, Rosmarinus officinalis, and Thymus capitatus was analyzed using gas chromatography-mass spectrometry. A rabbit model was used to assess skin irritation caused by the oils. In addition, the anti-biofilm activity of the oils used alone or in combination with chlorhexidine-gluconate or chlorhexidine-gluconate plus isopropyl alcohol was tested against S. epidermidis biofilms. Essential oil concentrations 10%, 20%, and 30% were chosen for anti-biofilm assays, because skin irritation was observed at concentrations greater than 30%. All oils except for O. marjoram had anti-biofilm activity at these three concentrations. L. multifida synergistically enhanced the anti-biofilm activity of chlorhexidine-gluconate and resulted in the highest anti-biofilm activity observed when combined with chlorhexidine-gluconate plus isopropyl alcohol. Gas chromatography-mass spectrometry revealed that the main component contributing to the activity of L. multifida oil was a natural terpene alcohol called linalool. The anti-biofilm activity of chlorhexidine-gluconate plus isopropyl alcohol can be greatly enhanced by L. multifida oil or linalool. Therefore, these components could potentially be used to improve blood donor skin disinfection. © 2017 AABB.
Panchaxari, Dandigi M; Pampana, Sowjanya; Pal, Tapas; Devabhaktuni, Bhavana; Aravapalli, Anil Kumar
2013-01-07
The objective of the study was to develop and characterize Diclofenac Diethylamine (DDEA) transdermal patch using Silicone and acrylic adhesives combination. Modified solvent evaporation method was employed for casting of film over Fluoropolymer coated polyester release liner. Initial studies included solubilization of drug in the polymers using solubilizers. The formulations with combination of adhesives were attempted to combine the desirable features of both the adhesives. The effect of the permeation enhancers on the drug permeation were studied using pig ear skin. All the optimized patches were subjected to adhesion, dissolution and stability studies. A 7-day skin irritancy test on albino rabbits and an in vivo anti-inflammatory study on wistar rats by carrageenan induced paw edema method were also performed. The results indicated the high percent drug permeation (% CDP-23.582) and low solubility nature (1%) of Silicone adhesive and high solubility (20%) and low% CDP (10.72%) of acrylic adhesive. The combination of adhesives showed desirable characteristics for DDEA permeation with adequate % CDP and sufficient solubility. Release profiles were found to be dependent on proportion of polymer and type of permeation enhancer. The anti-inflammatory study revealed the sustaining effect and high percentage inhibition of edema of C4/OLA (99.68%). The acute skin irritancy studies advocated the non-irritant nature of the adhesives used. It was concluded that an ideal of combination of adhesives would serve as the best choice, for fabrication of DDEA patches, for sustained effect of DDEA with better enhancement in permeation characteristics and robustness.
2013-01-01
Background and purpose of the study The objective of the study was to develop and characterize Diclofenac Diethylamine (DDEA) transdermal patch using Silicone and acrylic adhesives combination. Methods Modified solvent evaporation method was employed for casting of film over Fluoropolymer coated polyester release liner. Initial studies included solubilization of drug in the polymers using solubilizers. The formulations with combination of adhesives were attempted to combine the desirable features of both the adhesives. The effect of the permeation enhancers on the drug permeation were studied using pig ear skin. All the optimized patches were subjected to adhesion, dissolution and stability studies. A 7-day skin irritancy test on albino rabbits and an in vivo anti-inflammatory study on wistar rats by carrageenan induced paw edema method were also performed. Results The results indicated the high percent drug permeation (% CDP-23.582) and low solubility nature (1%) of Silicone adhesive and high solubility (20%) and low% CDP (10.72%) of acrylic adhesive. The combination of adhesives showed desirable characteristics for DDEA permeation with adequate % CDP and sufficient solubility. Release profiles were found to be dependent on proportion of polymer and type of permeation enhancer. The anti-inflammatory study revealed the sustaining effect and high percentage inhibition of edema of C4/OLA (99.68%). The acute skin irritancy studies advocated the non-irritant nature of the adhesives used. Conclusion It was concluded that an ideal of combination of adhesives would serve as the best choice, for fabrication of DDEA patches, for sustained effect of DDEA with better enhancement in permeation characteristics and robustness. PMID:23351568
Schliemann, Sibylle; Schmidt, Christina; Elsner, Peter
2014-01-01
The objective of our study was to investigate the tandem irritation potential of two organic solvents with concurrent exposure to the hydrophilic detergent irritant sodium lauryl sulphate (SLS). A tandem repeated irritation test was performed with two undiluted organic solvents, cumene (C) and octane (O), with either alternating application with SLS 0.5% or twice daily application of each irritant alone in 27 volunteers on the skin of the back. The cumulative irritation induced over 4 days was quantified using visual scoring and non-invasive bioengineering measurements (skin colour reflectance, skin hydration and transepidermal water loss). Repeated application of C/SLS and O/SLS induced more decline of stratum corneum hydration and higher degrees of clinical irritation and erythema compared to each irritant alone. Our results demonstrate a further example of additive harmful skin effects induced by particular skin irritants and indicate that exposure to organic solvents together with detergents may increase the risk of acquiring occupational contact dermatitis. © 2014 S. Karger AG, Basel.
Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina
2015-09-01
The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%).
Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina
2014-01-01
The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%). PMID:27134543
Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-Ichiro
2009-06-01
A validation study of an in vitro skin irritation testing method using a reconstructed human skin model has been conducted by the European Centre for the Validation of Alternative Methods (ECVAM), and a protocol using EpiSkin (SkinEthic, France) has been approved. The structural and performance criteria of skin models for testing are defined in the ECVAM Performance Standards announced along with the approval. We have performed several evaluations of the new reconstructed human epidermal model LabCyte EPI-MODEL, and confirmed that it is applicable to skin irritation testing as defined in the ECVAM Performance Standards. We selected 19 materials (nine irritants and ten non-irritants) available in Japan as test chemicals among the 20 reference chemicals described in the ECVAM Performance Standard. A test chemical was applied to the surface of the LabCyte EPI-MODEL for 15 min, after which it was completely removed and the model then post-incubated for 42 hr. Cell v iability was measured by MTT assay and skin irritancy of the test chemical evaluated. In addition, interleukin-1 alpha (IL-1alpha) concentration in the culture supernatant after post-incubation was measured to provide a complementary evaluation of skin irritation. Evaluation of the 19 test chemicals resulted in 79% accuracy, 78% sensitivity and 80% specificity, confirming that the in vitro skin irritancy of the LabCyte EPI-MODEL correlates highly with in vivo skin irritation. These results suggest that LabCyte EPI-MODEL is applicable to the skin irritation testing protocol set out in the ECVAM Performance Standards.
16 CFR 1500.42 - Test for eye irritants.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Test for eye irritants. 1500.42 Section 1500... eye irritants. (a)(1) Six albino rabbits are used for each test substance. Animal facilities for such... materials that might produce eye irritation. Both eyes of each animal in the test group shall be examined...
Effects of Lycopersicon esculentum extract on hair growth and alopecia prevention.
Choi, Jae-Suk; Jung, Sung Kyu; Jeon, Min-Hee; Moon, Jin-Nam; Moon, Woi-Sook; Ji, Yi-Hwa; Choi, In Soon; Wook Son, Sang
2013-01-01
To evaluate the potential hair growth-promoting activity and the expression of cell growth factors of Lycopersicon esculentum extracts, each 3% (w/w) of ethyl acetate extract (EAE), and supercritical CO2 extract (SCE) of L. esculentum and isolated lycopene Tween 80 solution (LTS) and test hair tonic (THT) containing LTS were applied on the dorsal skin of C57BL/6 mice, once a day for 4 weeks. At week 4, LTS and THT exhibited hair growth-promoting potential similar to that of 3% minoxidil as a positive control (PC). Further, in the LTS group, a significant increase of mRNA expression of vascular endothelial growth factor (VEGF), keratinocyte growth factor, and insulin-like growth factor-1 (IGF-1) was observed than PC, as well as the negative control (NC). In the THT group, increases in IGF-1 and decrease in VEGF and transforming growth factor-β expression were significant over the NC. In a histological examination in the THT group, the induction of anagen stage of hair follicles was faster than that of NC. In the Draize skin irritation study for THT, no observable edema or erythema was observed on all four sectors in the back skin after exposure for 24 or 72 h for any rabbit. Therefore, this study provides reasonable evidence that L. esculentum extracts promote hair growth and suggests that applications could be found in hair loss treatments without skin irritation at moderate doses.
Comparative acute toxicity of shale and petroleum derived distillates.
Clark, C R; Ferguson, P W; Katchen, M A; Dennis, M W; Craig, D K
1989-12-01
In anticipation of the commercialization of its shale oil retorting and upgrading process, Unocal Corp. conducted a testing program aimed at better defining potential health impacts of a shale industry. Acute toxicity studies using rats and rabbits compared the effects of naphtha, Jet-A, JP-4, diesel and "residual" distillate fractions of both petroleum derived crude oils and hydrotreated shale oil. No differences in the acute oral (greater than 5 g/kg LD50) and dermal (greater than 2 g/kg LD50) toxicities were noted between the shale and petroleum derived distillates and none of the samples were more than mildly irritating to the eyes. Shale and petroleum products caused similar degrees of mild to moderate skin irritation. None of the materials produced sensitization reactions. The LC50 after acute inhalation exposure to Jet-A, shale naphtha, (greater than 5 mg/L) and JP-4 distillate fractions of petroleum and shale oils was greater than 5 mg/L. The LC50 of petroleum naphtha (greater than 4.8 mg/L) and raw shale oil (greater than 3.95 mg/L) also indicated low toxicity. Results demonstrate that shale oil products are of low acute toxicity, mild to moderately irritating and similar to their petroleum counterparts. The results further demonstrate that hydrotreatment reduces the irritancy of raw shale oil.
A comprehensive evaluation of the carcinogenic potential of middle distillate fuels.
Nessel, C S
1999-02-01
Middle distillate fuels (MDFs), which include jet fuel, kerosene, and diesel fuel, are a class of hydrocarbons distilled from crude oil at approximately 350-700 degrees F (176-371 degrees C). Although MDFs generally do not contain appreciable levels of potentially carcinogenic polycyclic aromatic compounds (PACs), they have produced weak tumorigenic responses in mouse skin characterized by low tumor yield and long latency. Recent studies demonstrated that the tumorigenic effects of these MDFs were dependent upon chronic dermal irritation. In the absence of skin irritation, tumors did not develop. Mechanistic studies suggest that straight-run MDFs containing low levels of PACs cause skin tumors through a nongenotoxic mechanism. MDFs cause chronic skin irritation and injury with repeated application to the skin. They have been found to have little or no activity in the modified Ames mutagenicity assay, lack tumor initiating activity, and are active skin tumor promoters. It has been hypothesized that the tumorigenic response to MDFs results from the promotion of preexisting, spontaneously initiated cells. Two recent studies, a one-year tumor promotion study and a two-year skin painting study, evaluated the role of skin irritation on the tumorigenic activity of MDFs in mice. MDFs were applied in pure and diluted forms to assess the effect of equal weekly doses of irritating and nonirritating test materials. The tumorigenicity of straight-run MDFs correlated to the level of skin irritation. No significant increase in tumor incidence occurred under conditions that resulted in minimal skin irritation and injury. These studies indicate that the tumorigenic activity of MDFs containing low levels of PACs is secondary to chronic skin irritation. These materials should not present a carcinogenic hazard in the absence of prolonged skin irritation.
Radtke, M A; Lee-Seifert, C; Rustenbach, S J; Schäfer, I; Augustin, M
2009-05-01
Products containing dexpanthenol are used to treat irritated and inflamed skin. So far there is a lack of data for the evidence of patient-relevant benefits. Assessment of the patient-relevant benefit of ointments containing dexpanthenol in the self-medicated therapy of irritated skin. Prospective, observational study in a network of 392 pharmacies. Consecutive recruitment of n=1,886 patients with symptoms of irritated skin, including non-inflammatory intervals of atopic eczema, other xerotic skin conditions and impairment of skin barrier. The patient-relevant benefit was ascertained prior to and 7-10 days after treatment through the patient-benefit index (PBI). The PBI showed that 91.5% of the patients experienced a relevant benefit from treatment. 94.7% directly indicated to have had achieved successful therapeutic results. All symptoms of irritated skin (e.g. xerosis, erythema, desquamation) significantly improved (p
Yun, Jun-Won; Hailian, Quan; Na, Yirang; Kang, Byeong-Cheol; Yoon, Jung-Hee; Cho, Eun-Young; Lee, Miri; Kim, Da-Eun; Bae, SeungJin; Seok, Seung Hyeok; Lim, Kyung-Min
2016-12-01
In an effort to explore the use of alternative methods to animal testing for the evaluation of the ocular irritancy of medical devices, we evaluated representative contact lenses with the bovine corneal opacity and permeability test (BCOP) and an in vitro eye irritation test using the three-dimensionally-reconstructed human corneal epithelium (RhCE) models, EpiOcular™ and MCTT HCE™. In addition, we compared the obtained results with the ISO standard in vivo rabbit eye irritation test (ISO10993-10). Along with the positive controls (benzalkonium chloride, BAK, 0.02, 0.2, and 1%), the extracts of 4 representative contact lenses (soft, disposable, hard, and colored lenses) and 2 reference lenses (dye-eluting and BAK-coated lenses) were tested. All the lenses, except for the BAK-coated lens, were determined non-irritants in all test methods, while the positive controls yielded relevant results. More importantly, BCOP, EpiOcular™, and MCTT HCE™ yielded a consistent decision for all the tested samples, with the exception of 0.2% BAK in BCOP, for which no prediction could be made. Overall, all the in vitro tests correlated well with the in vivo rabbit eye irritation test, and furthermore, the combination of in vitro tests as a tiered testing strategy was able to produce results similar to those seen in vivo. These observations suggest that such methods can be used as alternative assays to replace the conventional in vivo test method in the evaluation of the ocular irritancy of ophthalmic medical devices, although further study is necessary. Copyright © 2016. Published by Elsevier Ltd.
Chen, Hongxia; Li, Shuhua; Meng, Tian; Zhang, Lei; Dai, Taoli; Xiang, Qi; Su, Zhijian; Zhang, Qihao; Huang, Yadong
2014-04-21
In vitro alternative tests aiming at replacing the traditional animal test for predicting the irritant potential of chemicals have been developed, but the assessing parameters or endpoints are still not sufficient. To discover novel endpoints for skin irritation responses, 2DE-based proteomics was used to analyze the protein expression in human skin exposed to sodium lauryl sulfate (SLS) following the test protocol of the European Centre for the Validation of Alternative Methods (ECVAM) in the present study. HSP27 was up-regulated most significantly among the eight identified proteins, consistent with our previous reports. Acid and basic chemicals were applied on human skin for further validation and results showed that the up-regulated expression of HSP27 was induced in 24h after the exposure. Skin-equivalent constructed with fibroblasts, basement membrane and keratinocytes was used to investigate the potential of HSP27 as a biomarker or additional endpoint for the hazard assessment of skin irritation. Our skin-equivalent (Reconstructed Organotypic Skin Model, ROSM) had excellent epidermal differentiation and was suitable for the skin irritation test. HSP27 also displayed an up-regulated expression in the ROSM in 24h after the irritants exposure for 15min. All these results suggest that HSP27 may represent a potential marker or additional endpoint for the hazard assessment of skin irritation caused by chemical products. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Formulation study of topically applied lotion: in vitro and in vivo evaluation.
Hussain Shah, Syed Nisar; Hussain, Talib; Ullah Khan, Ikram; Asghar, Sajid; Shahzad, Yasser
2013-01-01
This article presents the development and evaluation of a new topical formulation of diclofenac diethylamine (DDA) as a locally applied analgesic lotion. To this end, the lotion formulations were formulated with equal volume of varying concentrations (1%, 2%, 3%, 4%; v/v) of permeation enhancers, namely propylene glycol (PG) and turpentine oil (TO). These lotions were subjected to physical studies (pH, viscosity, spreadability, homogeneity, and accelerated stability), in vitro permeation, in vivo animal studies and sensatory perception testing. In vitro permeation of DDA from lotion formulations was evaluated across polydimethylsiloxane membrane and rabbit skin using Franz cells. It was found that PG and TO content influenced the permeation of DDA across model membranes with the lotion containing 4% v/v PG and TO content showed maximum permeation enhancement of DDA. The flux values for L4 were 1.20±0.02 μg.cm(-2).min(-1) and 0.67 ± 0.02 μg.cm(-2).min(-1) for polydimethylsiloxane and rabbit skin, respectively. Flux values were significantly different (p < 0.05) from that of the control. The flux enhancement ratio of DDA from L4 was 31.6-fold and 4.8-fold for polydimethylsiloxane and rabbit skin, respectively. In the in vivo animal testing, lotion with 4% v/v enhancer content showed maximum anti-inflammatory and analgesic effect without inducing any irritation. Sensatory perception tests involving healthy volunteers rated the formulations between 3 and 4 (values ranging between -4 to +4, indicating a range of very bad to excellent, respectively). It was concluded that the DDA lotion containing 4% v/v PG and TO exhibit the best performance overall and that this specific formulation should be the basis for further clinical investigations.
Formulation Study of Topically Applied Lotion: In Vitro and In Vivo Evaluation
Hussain Shah, Syed Nisar; Hussain, Talib; Ullah Khan, Ikram; Asghar, Sajid; Shahzad, Yasser
2013-01-01
Introduction This article presents the development and evaluation of a new topical formulation of diclofenac diethylamine (DDA) as a locally applied analgesic lotion. Methods To this end, the lotion formulations were formulated with equal volume of varying concentrations (1%, 2%, 3%, 4%; v/v) of permeation enhancers, namely propylene glycol (PG) and turpentine oil (TO). These lotions were subjected to physical studies (pH, viscosity, spreadability, homogeneity, and accelerated stability), in vitro permeation, in vivo animal studies and sensatory perception testing. In vitro permeation of DDA from lotion formulations was evaluated across polydimethylsiloxane membrane and rabbit skin using Franz cells. Results It was found that PG and TO content influenced the permeation of DDA across model membranes with the lotion containing 4% v/v PG and TO content showed maximum permeation enhancement of DDA. The flux values for L4 were 1.20±0.02 μg.cm-2.min-1 and 0.67 ± 0.02 μg.cm-2.min-1 for polydimethylsiloxane and rabbit skin, respectively. Flux values were significantly different (p < 0.05) from that of the control. The flux enhancement ratio of DDA from L4 was 31.6-fold and 4.8-fold for polydimethylsiloxane and rabbit skin, respectively. In the in vivo animal testing, lotion with 4% v/v enhancer content showed maximum anti-inflammatory and analgesic effect without inducing any irritation. Sensatory perception tests involving healthy volunteers rated the formulations between 3 and 4 (values ranging between -4 to +4, indicating a range of very bad to excellent, respectively). Conclusion It was concluded that the DDA lotion containing 4% v/v PG and TO exhibit the best performance overall and that this specific formulation should be the basis for further clinical investigations. PMID:23678465
The use of nanoencapsulation to decrease human skin irritation caused by capsaicinoids
Contri, Renata V; Frank, Luiza A; Kaiser, Moacir; Pohlmann, Adriana R; Guterres, Silvia S
2014-01-01
Capsaicin, a topical analgesic used in the treatment of chronic pain, has irritant properties that frequently interrupt its use. In this work, the effect of nanoencapsulation of the main capsaicinoids (capsaicin and dihydrocapsaicin) on skin irritation was tested in humans. Skin tolerance of a novel vehicle composed of chitosan hydrogel containing nonloaded nanocapsules (CH-NC) was also evaluated. The chitosan hydrogel containing nanoencapsulated capsaicinoids (CH-NC-CP) did not cause skin irritation, as measured by an erythema probe and on a visual scale, while a formulation containing free capsaicinoids (chitosan gel with hydroalcoholic solution [CH-ET-CP]) and a commercially available capsaicinoids formulation caused skin irritation. Thirty-one percent of volunteers reported slight irritation one hour after application of CH-NC-CP, while moderate (46% [CH-ET-CP] and 23% [commercial product]) and severe (8% [CH-ET-CP] and 69% [commercial product]) irritation were described for the formulations containing free capsaicinoids. When CH-NC was applied to the skin, erythema was not observed and only 8% of volunteers felt slight irritation, which demonstrates the utility of the novel vehicle. A complementary in vitro skin permeation study showed that permeation of capsaicinoids through an epidermal human membrane was reduced but not prevented by nanoencapsulation. PMID:24611011
Effect of topically applied lipids on surfactant-irritated skin.
Lodén, M; Andersson, A C
1996-02-01
Moisturizers are used daily by many people to alleviate symptoms of dry skin. All of them contain lipids. It has been suggested that topically applied lipids may interfere with the structure and function of the permeability barrier. The influence of a single application of nine different lipids on normal skin and skin irritated by sodium lauryl sulphate (SLS) was studied in 21 healthy subjects. Parameters assessed were visible signs of irritation, and objectively measured cutaneous blood flow and transepidermal water loss (TEWL). The substances tested were hydrocortisone, petrolatum, fish oil, borage oil, sunflower seed oil, canola oil, shea butter, and fractions of unsaponifiable lipids from canola oil and shea butter. Water was included as a control. On normal skin, no significant differences in the effects of the test substances were found, whereas significant differences were observed when they were applied to SLS-irritated skin. The visible signs of SLS-induced irritation were significantly less pronounced after treatment with the sterol-enriched fraction from canola oil than after treatment with water. This fraction, and hydrocortisone, reduced cutaneous blood flow. Furthermore, application of hydrocortisone, canola oil, and its sterol-enriched fraction, resulted in significantly lower TEWL than with water. The other lipids had no effect on the degree of irritation. In conclusion, lipids commonly used in moisturizers may reduce skin reactions to irritants. Previous studies have shown that, in barrier perturbed skin, the synthesis of sterols is increased. The observed effects of canola oil and its fraction of unsaponifiable lipids on SLS-induced irritation suggest the possibility that they assisted the skin in supplying the damaged barrier with adequate lipids.
Lung reflexes in rabbits during pulmonary stretch receptor block by sulphur dioxide.
Davies, A; Dixon, M; Callanan, D; Huszczuk, A; Widdicombe, J G; Wise, J C
1978-07-01
Anaesthetized rabbits were given 200 ppm sulphur dioxide to breathe for 10 min. This abolished activity in 23 of 26 pulmonary stretch receptors, while leaving that of lung irritant receptors unimpaired. The Breuer-Hering reflex was abolished and breathing became deeper and slower. Inspiratory time (tI) was increased and expiratory time (tE) decreased. Subsequent vagotomy increased tidal volume (VT), tI and tE. In animals with stretch receptors blocked, injections of phenyl diguanide and histamine still increased breathing frequency and decreased VT, indicating that reflexes from lung irritant and J-receptors were intact. Inhalation of 8% CO2 caused a bigger increase in frequency and tidal volume in rabbits with stretch receptor block compared with controls or those after vagotomy. Induction of pneumothorax with stretch receptor block transiently prolonged tI and shortened tE; removal of the pneumothorax also transiently shortened tE and usually also decreased tI. The results suggest that lung irritant receptors reflexly shorten tE in all our experimental conditions, but have various effects on tI which may depend on the timing of the irritant receptor discharge and refractoriness of the inspiratory response.
In vivo acute toxicological studies of an antioxidant extract from Mangifera indica L. (Vimang).
Garrido, Gabino; Rodeiro, Idania; Hernández, Ivones; García, Gastón; Pérez, Gema; Merino, Nelson; Núñez-Sellés, Alberto; Delgado, René
2009-01-01
Mango (Mangifera indica L.) stem bark aqueous extract (MSBE) is a natural product with antioxidant, anti-inflammatory, analgesic, and immunomodulatory effects. Its formulations (e.g., tablets, capsules, syrup, vaginal oval, and suppositories) are known by the brand name of Vimang. In view of the ethnomedical, preclinical, and clinical uses of this extract and the necessity to assess its possible toxicological effect on man, a toxicological analysis of a standard extract is reported in this paper. Acute toxicity was evaluated in mice and rats by oral, dermal, and intraperitoneal (i.p.) administration. The extract, by oral or dermal administration, showed no lethality at the limit doses of 2,000 mg/kg body weight and no adverse effects were found. Deaths occurred with the i.p. administration at 200, but not 20 mg/kg in mice. MSBE was also studied on irritant tests in rabbits, and the results showed that it was nonirritating on skin, ocular, or rectal mucosa. The extract had minimal irritancy following vaginal application.
Final report on the safety assessment of benzaldehyde.
Andersen, Alan
2006-01-01
Benzaldehyde is an aromatic aldehyde used in cosmetics as a denaturant, a flavoring agent, and as a fragrance. Currently used in only seven cosmetic products, its highest reported concentration of use was 0.5% in perfumes. Benzaldehyde is a generally regarded as safe (GRAS) food additive in the United States and is accepted as a flavoring substance in the European Union. Because Benzaldehyde rapidly metabolizes to Benzoic Acid in the skin, the available dermal irritation and sensitization data demonstrating no adverse reactions to Benzoic Acid were considered supportive of the safety of Benzaldehyde. Benzaldehyde is absorbed through skin and by the lungs, distributes to all well-perfused organs, but does not accumulate in any specific tissue type. After being metabolized to benzoic acid, conjugates are formed with glycine or glucuronic acid, and excreted in the urine. Little acute toxicity was seen. The oral LD(50) of Benzaldehyde in rats and mice ranged from 800 to 2850 mg/kg. The intraperitoneal LD(50) in white rats was 3265 mg/kg. In short-term oral studies, the no observed adverse effect level (NOAEL) was 400 mg/kg in rats and mice. In subchronic oral studies, the NOAEL was 400 mg/kg in rats and 600 mg/kg in mice. In a 16-week feeding study, rats given up to 10,000 ppm showed no signs of toxicity. Repeated inhalation of volatilized Benzaldehyde produced ocular and nasal irritation at 500 ppm and death in rabbits at 750 ppm. Undiluted Benzaldehyde was irritating to rabbit eyes, causing edema, erythema, and pain. Benzaldehyde was determined not to be a contact sensitizer, but did produce allergic reactions in a maximization test. Clinical reports of allergy to Benzaldehyde are rare. Benzoic Acid did not produce irritation or sensitization reactions in human clinical studies. Benzoic Acid also failed to produce reactions in phototoxicity and photosensitization tests. Neither Benzaldehyde, Benzoic Acid, nor Sodium Benzoate are reproductive or developmental toxicants at doses that are nontoxic to the mother. In a behavioral study, blood levels of 0.12 ng/ml Benzaldehyde produced a 44% reduction in motor activity in mice. Benzaldehyde did not produce mutations in bacterial assays, but did produce chromosomal abnormalities in Chinese hamster cells and increased mutations in a mouse lymphoma forward mutation assay. Benzaldehyde was evaluated by the National Toxicology Program, which found no evidence of carcinogenicity in rats, and some evidence of carcinogenicity in mice. Several studies have suggested that Benzaldehyde can have carcinostatic or antitumor properties. Overall, at the concentrations used in cosmetics, Benzaldehyde was not considered a carcinogenic risk to humans. Although there are limited irritation and sensitization data available for Benzaldehyde, the available dermal irritation and sensitization data and ultraviolet (UV) absorption and phototoxicity data demonstrating no adverse reactions to Benzoic Acid support the safety of Benzaldehyde as currently used in cosmetic products.
Screening for eye irritancy using cultured HeLa cells.
Selling, J; Ekwall, B
1985-01-01
To investigate whether toxicity tests on HeLa cells were predictive of eye irritancy, 18 compounds of known eye irritancy and in vitro cytotoxicity were tested on HeLa cells in the MIT-24 system. The results correlated well with eye irritancy as determined by the Draize test in rabbits for 16 of the test substances, but failed to detect the high eye irritancy of 1-heptanol and allyl alcohol, both of which were cytotoxic in other cellular systems.
Adverse reactions to cosmetics and methods of testing.
Nigam, P K
2009-01-01
Untoward reactions to cosmetics, toiletries, and topical applications are the commonest single reason for hospital referrals with allergic contact dermatitis. In most cases, these are only mild or transient and most reactions being irritant rather than allergic in nature. Various adverse effects may occur in the form of acute toxicity, percutaneous absorption, skin irritation, eye irritation, skin sensitization and photosensitization, subchronic toxicity, mutagenicity/genotoxicity, and phototoxicity/photoirritation. The safety assessment of a cosmetic product clearly depends upon how it is used, since it determines the amount of substance which may be ingested, inhaled, or absorbed through the skin or mucous membranes. Concentration of ingredients used in the different products is also important. Various test procedures include in vivo animal models and in vitro models, such as open or closed patch test, in vivo skin irritation test, skin corrosivity potential tests (rat skin transcutaneous electrical resistance test, Episkin test), eye irritation tests (in vivo eye irritancy test and Draize eye irritancy test), mutagenicity/genotoxicity tests (in vitro bacterial reverse mutation test and in vitro mammalian cell chromosome aberration test), and phototoxicity/photoirritation test (3T3 neutral red uptake phototoxicity test). Finished cosmetic products are usually tested in small populations to confirm the skin and mucous membrane compatibility, and to assess their cosmetic acceptability.
Skin irritation, false positives and the local lymph node assay: a guideline issue?
Basketter, David A; Kimber, Ian
2011-10-01
Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential. Copyright © 2011 Elsevier Inc. All rights reserved.
The Ex Vivo Eye Irritation Test as an alternative test method for serious eye damage/eye irritation.
Spöler, Felix; Kray, Oya; Kray, Stefan; Panfil, Claudia; Schrage, Norbert F
2015-07-01
Ocular irritation testing is a common requirement for the classification, labelling and packaging of chemicals (substances and mixtures). The in vivo Draize rabbit eye test (OECD Test Guideline 405) is considered to be the regulatory reference method for the classification of chemicals according to their potential to induce eye injury. In the Draize test, chemicals are applied to rabbit eyes in vivo, and changes are monitored over time. If no damage is observed, the chemical is not categorised. Otherwise, the classification depends on the severity and reversibility of the damage. Alternative test methods have to be designed to match the classifications from the in vivo reference method. However, observation of damage reversibility is usually not possible in vitro. Within the present study, a new organotypic method based on rabbit corneas obtained from food production is demonstrated to close this gap. The Ex Vivo Eye Irritation Test (EVEIT) retains the full biochemical activity of the corneal epithelium, epithelial stem cells and endothelium. This permits the in-depth analysis of ocular chemical trauma beyond that achievable by using established in vitro methods. In particular, the EVEIT is the first test to permit the direct monitoring of recovery of all corneal layers after damage. To develop a prediction model for the EVEIT that is comparable to the GHS system, 37 reference chemicals were analysed. The experimental data were used to derive a three-level potency ranking of eye irritation and corrosion that best fits the GHS categorisation. In vivo data available in the literature were used for comparison. When compared with GHS classification predictions, the overall accuracy of the three-level potency ranking was 78%. The classification of chemicals as irritating versus non-irritating resulted in 96% sensitivity, 91% specificity and 95% accuracy. 2015 FRAME.
Formulation, in vitro and in vivo evaluation of transdermal patches containing risperidone.
Aggarwal, Geeta; Dhawan, Sanju; Hari Kumar, S L
2013-01-01
The efficacy of oral risperidone treatment in prevention of schizophrenia is well known. However, oral side effects and patient compliance is always a problem for schizophrenics. In this study, risperidone was formulated into matrix transdermal patches to overcome these problems. The formulation factors for such patches, including eudragit RL 100 and eudragit RS 100 as matrix forming polymers, olive oil, groundnut oil and jojoba oil in different concentrations as enhancers and amount of drug loaded were investigated. The transdermal patches containing risperidone were prepared by solvent casting method and characterized for physicochemical and in vitro permeation studies through excised rat skin. Among the tested preparations, formulations with 20% risperidone, 3:2 ERL 100 and ERS 100 as polymers, mixture of olive oil and jojoba oil as enhancer, exhibited greatest cumulative amount of drug permeated (1.87 ± 0.09 mg/cm(2)) in 72 h, so batch ROJ was concluded as optimized formulation and assessed for pharmacokinetic, pharmacodynamic and skin irritation potential. The pharmacokinetic characteristics of the optimized risperidone patch were determined using rabbits, while orally administered risperidone in solution was used for comparison. The calculated relative bioavailability of risperidone transdermal patch was 115.20% with prolonged release of drug. Neuroleptic efficacy of transdermal formulation was assessed by rota-rod and grip test in comparison with control and marketed oral formulations with no skin irritation. This suggests the transdermal application of risperidone holds promise for improved bioavailability and better management of schizophrenia in long-term basis.
Validation study of the in vitro skin irritation test with the LabCyte EPI-MODEL24.
Kojima, Hajime; Ando, Yoko; Idehara, Kenji; Katoh, Masakazu; Kosaka, Tadashi; Miyaoka, Etsuyoshi; Shinoda, Shinsuke; Suzuki, Tamie; Yamaguchi, Yoshihiro; Yoshimura, Isao; Yuasa, Atsuko; Watanabe, Yukihiko; Omori, Takashi
2012-03-01
A validation study on an in vitro skin irritation assay was performed with the reconstructed human epidermis (RhE) LabCyte EPI-MODEL24, developed by Japan Tissue Engineering Co. Ltd (Gamagori, Japan). The protocol that was followed in the current study was an optimised version of the EpiSkin protocol (LabCyte assay). According to the United Nations Globally Harmonised System (UN GHS) of classification for assessing the skin irritation potential of a chemical, 12 irritants and 13 non-irritants were validated by a minimum of six laboratories from the Japanese Society for Alternatives to Animal Experiments (JSAAE) skin irritation assay validation study management team (VMT). The 25 chemicals were listed in the European Centre for the Validation of Alternative Methods (ECVAM) performance standards. The reconstructed tissues were exposed to the chemicals for 15 minutes and incubated for 42 hours in fresh culture medium. Subsequently, the level of interleukin-1 alpha (IL-1 α) present in the conditioned medium was measured, and tissue viability was assessed by using the MTT assay. The results of the MTT assay obtained with the LabCyte EPI-MODEL24 (LabCyte MTT assay) demonstrated high within-laboratory and between-laboratory reproducibility, as well as high accuracy for use as a stand-alone assay to distinguish skin irritants from non-irritants. In addition, the IL-1α release measurements in the LabCyte assay were clearly unnecessary for the success of this model in the classification of chemicals for skin irritation potential. 2012 FRAME.
Long-term repetitive sodium lauryl sulfate-induced irritation of the skin: an in vivo study.
Branco, Nara; Lee, Ivy; Zhai, Hongbo; Maibach, Howard I
2005-11-01
Skin may adapt to topical irritants through accommodation. This study focuses on long-term exposure to irritants and attempts to demonstrate accommodation. Sodium lauryl sulfate (SLS) induced irritant contact dermatitis at 3 concentrations (0.025% to 0.075%). Distilled water, acetone and an empty chamber served as controls. Experimental compounds were applied to forearms of 7 healthy volunteers for 24 hr before replacing by a fresh chamber for 6 non-consecutive weeks over 103 days. Possible accommodation was quantified by visual scoring (erythema and dryness) and by bioengineering parameters: transepidermal water loss (TEWL), capacitance, chromametry and laser Doppler flowmetry (LDF). Significant erythema, dryness, elevated TEWL, skin colour reflectance and LDF values occurred during the exposure periods. Upon repeat exposure, an immediate and augmented response in erythema, TEWL, skin colour reflectance and LDF developed. However, irritant skin changes were not sustained. Irritation parameters return to baseline after cessation of exposure. There was no evidence of sustained irritation or accommodation after the last exposure. Study findings do not document sustained accommodation or adaptive hyposensitivity after long-term repetitive irritant exposure under these test conditions. Alternative models should be developed to prove or disprove the accommodation hypothesis.
Safety assessment of azelaic acid and its derivatives entrapped in nanovesicles.
Panyosak, A; Manosroi, J; Rojanasakul, Y; Manosroi, A
2009-06-01
The aim of this study was to determine the safety of azelaic acid (AA) and its derivatives in nanovesicles for pharmaceutical and cosmetic uses. The hydrophilic property of AA was modified by complexing AA with hydroxypropyl-beta-cyclodextrin (AACD). The lipophilic property of AA was improved to diethyl azelate (DA) by esterification with Fischer reaction. AA, AACD and DA were entrapped in liposomes and niosomes with the compositions of L-alpha-dipalmitoyl phosphatidylcholine/cholesterol = 7:3 and Tween 61/cholesterol = 1:1, respectively, by chloroform film method with sonication. The size of the vesicles ranged from 50 to 200 nm, indicating nanosize characteristics. The cytotoxicity of AA, AACD and DA entrapped nanovesicular formulations on mouse epidermal cell lines (JB6, normal cell lines) by the sulforhodamine B assay was modest when compared with cisplatin. Blank liposomes and niosomes gave no growth inhibitory effect. The irritation of AA, AACD and DA entrapped and not entrapped in nanovesicles on rabbit skin was examined according to the Environmental Protection Agency health effect test guidelines. The results showed no signs of erythema or edema within 72 h. AA and its derivatives were safe for topical use when entrapped in nanovesicles because of no toxicity to normal cell lines and no allergy on rabbit skin.
The identification and classification of skin irritation hazard by a human patch test.
Basketter, D A; Whittle, E; Griffiths, H A; York, M
1994-08-01
There exist various regulatory instruments the purpose of which is to ensure that the intrinsic toxic hazards associated with substances and preparations are identified. In the context of identification of skin irritation potential, the method is normally the Draize test. Guidance notes provided by the OECD and the EEC expect that corrosive substances will have been screened out by a variety of methods. Substances or preparations which cause a sufficient degree of skin irritation will be classified as skin irritants. The primary motivation behind the present work was to introduce the concept that it is possible to assess the hazard potential of a substance or preparation to produce skin irritation in a human study. In the example presented here, 20% sodium lauryl sulfate (SLS) has been chosen as the positive control. With the protocol currently devised, occluded patch treatment with 20% SLS for up to 4 hr produces an irritant response in just over half of the panel. An irritant response is taken as a clinically evident and significant increase in erythema, oedema or dryness--a minimum of a+ reaction on the ICDRG scale. At such a level of response with the positive control (both in terms of intensity and in proportion of the panel), it is then possible to judge and/or to determine statistically, whether the test material has produced a level of skin irritation which is similar to, greater, or lower than the positive control. In this way a human patch test protocol can form a fundamental component of a strategy for the replacement of animals in determination of skin irritation and corrosion potential. By use of a careful and progressive protocol and by comparison of test data against a positive control it is both possible and practical to classify substances and preparations in terms of their skin irritation potential using that endpoint in the species of concern, man.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-01
.... Studies included guinea pig maximization studies, in vivo ocular irritation studies in rabbits, and... C. I. Reactive Blue 247. Studies included guinea pig maximization studies, in vivo ocular irritation...
Wang, Liang; Shen, Tong; Zhou, Cheng-fan; Yu, Jun-feng; Zhu, Qi-xing
2009-04-01
To study the changes of nitric oxide (NO) in the BALB/c hairless mice skin after trichloroethylene (TCE) irritation and the protection of ginkgo biloba extract (GbE) and vitamin E (VE). 132 BALB/c hairless mice were randomly divided into blank control group, solvent group (olive oil), TCE groups (20%TCE, 40%TCE, 80%TCE and 100%TCE), GbE groups (0.1%GbE, 1%GbE and 10%GbE) and VE groups (5%VE, 10% VE and 20% VE), with 11 animals in each group, 5 for acute irritation test and 6 for the cumulative irritation test. The skin irritation was observed, and the levels of NO in the dorsal skin of BALB/C hairless mice were detected. The kit of NO was used to detect the levels of NO in the dorsal skin of BALB/c hairless mice. (1) The skin presented erythema and edema after TCE irritation both in acute irritation and cumulative irritation test and the skin inflammation showed time-dose effect relationship; the mice skin was protected in GbE or VE groups. (2) In the acute stimulation test, the levels of NO in 80%TCE group (69.895 +/- 9.605 micromol/mg pro) and 100%TCE group (77.273 +/- 9.290 micromol/mg pro) were significantly different compared with blank control group and solvent control group (P < 0.05 or P < 0.01). In the protection group, the NO level were reduced, with the statistically significant differences. (3) In acute irritation test, the levels of NO in 80%TCE group (60.362 +/- 9.817 micromol/mg pro) and 100%TCE group (68.027 +/- 9.354 micromol/mg pro) were significantly different compared with blank control group and solvent control group, (P < 0.05 or P < 0.01); In the protection group, 1% GbE, 10% GbE, 10% VE and 20%VE could reduce the levels of NO, with statistically significant differences. TCE can produce the irritation on the dorsal skin of BALB/c hairless mice and induce the significant increase of the NO levels. GbE and VE can protect the skin from TCE irritation damage.
The irritation potential and reservoir effect of mild soaps.
Lodén, Marie; Buraczewska, Izabela; Edlund, Fredrik
2003-08-01
Identification and reduction of external noxious factors is one key point in the strategy for the treatment and reduction of contact dermatitis. A wide variety of soaps on the market are claimed to be suitable for the use on sensitive skin due to their mildness. The aim of the present study was to illustrate possible differences in the irritation potential of 8 products and to investigate whether surfactant residues may form an irritant reservoir on the skin. The study was double-blind, randomized using healthy human volunteers. The inherent capacity of the products to induce irritation was determined using conventional patch test technique, whereas detection of potential surfactant residues on the skin was done using a methodology developed in the 1960s for detection of the corticosteroid reservoir in the stratum corneum. The method comprised the release of active substance from the stratum corneum reservoir by occlusion of the skin with an aluminium chamber, followed by evaluation of the biological response. In the present study, the soap-treated area was rinsed with water and then occluded. Instrumental measurements of the transepidermal water loss and superficial skin blood flow served as indicators of the injurious effects of the products. The results showed large differences in irritation potential between the products, and some of them demonstrated considerable damaging effect. Moreover, the study proved the presence of barrier-impairing residues on the skin after rinsing with water. Subclinical skin damage can make the skin vulnerable to further irritation and delay recovery of chronic irritant contact dermatitis.
Casari, Alice; Farnetani, Francesca; De Pace, Barbara; Losi, Amanda; Pittet, Jean-Christophe; Pellacani, Giovanni; Longo, Caterina
2017-03-01
Irritant contact dermatitis is caused by skin barrier damage. Vitamin E is an antioxidant that is commonly used in cosmetics to prevent photo-damage. To show the usefulness of reflectance confocal microscopy in the assessment of irritant skin damage caused by sodium lauryl sulfate (SLS) and of the protective action of vitamin E applied prior to skin irritation. Ten healthy volunteers were enrolled. Irritation was induced by the application of a patch test containing SLS 5% aq. for 24 h. Three sites were compared: one site on which a product with vitamin E was applied before SLS treatment, one site on which the same product was applied after SLS treatment, and one control site (SLS only). Each site was evaluated with reflectance confocal microscopy, providing in vivo tissue images at nearly histological resolution. We also performed a computerized analysis of the VivaStack® images. Reflectance confocal microscopy is able to identify signs of skin irritation and the preventive effect of vitamin E application. Reflectance confocal microscopy is useful in the objective assessment of irritative skin damage. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Kaunitz, Andrew M; Portman, David; Westhoff, Carolyn L; Mishell, Daniel R; Archer, David F; Foegh, Marie
2015-03-01
To evaluate skin irritation and patch adhesiveness of a new weekly low-dose levonorgestrel (LNG) and ethinyl estradiol (EE) contraceptive patch (LNG/EE patch). This analysis was part of an open-label, parallel-group, multicenter, phase 3 study that randomized healthy women to the LNG/EE patch (one patch weekly for three consecutive weeks, followed by a patch-free week for 13 cycles) or to an oral contraceptive for six cycles followed by seven LNG/EE patch cycles. Participants selected patch application sites of abdomen, buttock or upper torso. Investigators rated patch adhesiveness and skin irritation using standardized scales. Participants rated skin irritation and itching daily using standardized scales and recorded patch fall-off on daily diary cards. A total of 32,508 patches were applied (n=1273). At the five clinic visits in which investigators rated the patches, they rated adhesiveness=0 (no lift) for ≥84% of participants and skin irritation=absent/mild for 97% of patches. Participants reported that 2-3.7% of patches fell off and rated skin irritation as absent or mild for 92- 95% of patches, according to site. Investigator- and participant-rated assessments of LNG/EE patch adhesiveness and irritation demonstrated a low incidence of patch detachment, skin irritation and pruritus. This secondary analysis of a phase 3 clinical trial of a new weekly low-dose LNG and EE contraceptive patch, which used assessment by both investigators and participants, observed a low incidence of skin irritation, pruritus and patch detachment. Copyright © 2015 Elsevier Inc. All rights reserved.
Ignatova, Iu P; Kromin, A A
2011-01-01
In chronic experiences on rabbits the influence of electrostimulation of "the hunger centres" of the lateral hypothalamus (LH) on impulse activity of chewing muscles of rabbits under the conditions of hunger and satiation was studied. It is established, threshold irritation of the LH of hungry and preliminary fed animals in the absence of food caused the occurrence of incessant search behavior which was followed by the regular generation of bursts of AP by masseter and mylohyoideus muscles with bimodal distributions of interpulse intervals. Such reaction of chewing muscles during irritation of the LH in the absence of food is an example of advancing type reaction. The increase of level of alimentary motivation, arising at threshold irritation of the LH of rabbits under the conditions of hunger and satiety during the resultant food-intake behavior, increased frequency of generation of bursts of AP in a phase of the capture of food, but did not influence on this indicator in a phase of chewing of food. The received results testify about descending stimulating influences of alimentary motivational excitation on neurons of the chewing centre in medulla and on impulse activity of chewing muscles.
[News on occupational contact dermatitis].
Crépy, Marie-Noëlle; Bensefa-Colas, Lynda
2014-03-01
Contact dermatitis--irritant contact dermatitis, allergic contact dermatitis and protein contact dermatitis--are the most common occupational skin diseases, most often localized to the hands. Contact urticaria is rarer The main occupational irritants are wet work, detergents and disinfectants, cutting oils, and solvents. The main occupational allergens are rubber additives, metals (chromium, nickel, cobalt), plastics (epoxy resins, acrylic), biocides and plants. Diagnosis is based on clinical examination, medical history and allergy testing. For a number of irritating or sensitizing agents, irritant or allergic dermatitis can be notified as occupational diseases. The two main prevention measures are reducing skin contact with irritants and complete avoidance of skin contact with offending allergens.
Van Rompay, A R; Alépée, N; Nardelli, L; Hollanders, K; Leblanc, V; Drzewiecka, A; Gruszka, K; Guest, R; Kandarova, H; Willoughby, J A; Verstraelen, S; Adriaens, E
2018-06-01
Assessment of ocular irritancy is an international regulatory requirement and a necessary step in the safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as a stand-alone assay. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed with the goal of assessing the reliability of eight in vitro/alternative test methods as well as establishing an optimal tiered-testing strategy. One of the in vitro assays selected was the validated SkinEthic™ Human Corneal Epithelium Eye Irritation Test method (SkinEthic™ HCE EIT). The SkinEthic™ HCE EIT has already demonstrated its capacity to correctly identify chemicals (both substances and mixtures) not requiring classification and labelling for eye irritation or serious eye damage (No Category). The goal of this study was to evaluate the performance of the SkinEthic™ HCE EIT test method in terms of the important in vivo drivers of classification. For the performance with respect to the drivers all in vivo Cat 1 and No Cat chemicals were 100% correctly identified. For Cat 2 chemicals the liquids and the solids had a sensitivity of 100% and 85.7%, respectively. For the SkinEthic™ HCE EIT test method, 100% concordance in predictions (No Cat versus No prediction can be made) between the two participating laboratories was obtained. The accuracy of the SkinEthic™ HCE EIT was 97.5% with 100% sensitivity and 96.9% specificity. The SkinEthic™ HCE EIT confirms its excellent results of the validation studies. Copyright © 2017. Published by Elsevier Ltd.
Corvaro, M; Gehen, S; Andrews, K; Chatfield, R; Macleod, F; Mehta, J
2017-10-01
Analysis of the prevalence of health effects in large scale databases is key in defining testing strategies within the context of Integrated Approaches on Testing and Assessment (IATA), and is relevant to drive policy changes in existing regulatory toxicology frameworks towards non-animal approaches. A retrospective analysis of existing results from in vivo skin irritation, eye irritation, and skin sensitisation studies on a database of 223 agrochemical formulations is herein published. For skin or eye effects, high prevalence of mild to non-irritant formulations (i.e. per GHS, CLP or EPA classification) would generally suggest a bottom-up approach. Severity of erythema or corneal opacity, for skinor eye effects respectively, were the key drivers for classification, consistent with existing literature. The reciprocal predictivity of skin versus eye irritation and the good negative predictivity of the GHS additivity calculation approach (>85%) provided valuable non-testing evidence for irritation endpoints. For dermal sensitisation, concordance on data from three different methods confirmed the high false negative rate for the Buehler method in this product class. These results have been reviewed together with existing literature on the use of in vitro alternatives for agrochemical formulations, to propose improvements to current regulatory strategies and to identify further research needs. Copyright © 2017 Elsevier Inc. All rights reserved.
Tandem Repeated Irritation Test (TRIT) Studies and Clinical Relevance: Post 2006.
Reddy, Rasika; Maibach, Howard
2018-06-11
Single or multiple applications of irritants can lead to occupational contact dermatitis, and most commonly irritant contact dermatitis (ICD). Tandem irritation, the sequential application of two irritants to a target skin area, has been studied using the Tandem Repeated Irritation Test (TRIT) to provide a more accurate representation of skin irritation. Here we present an update to Kartono's review on tandem irritation studies since 2006 [1]. We surveyed the literature available on PubMed, Embase, Google Scholar, and the UCSF Dermatology library databases since 2006. The studies included discuss the tandem effects of common chemical irritants, organic solvents, occlusion as well as clinical relevance - and enlarge our ability to discern whether multiple chemical exposures are more or less likely to enhance irritation.
40 CFR 156.70 - Precautionary statements for human hazards.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., dermal, inhalation toxicity) Irritation effects (skin and eye) Sensitizer (There are no categories of... or spray mist]. Do not get in eyes, on skin, or on clothing. [Front panel first aid statement required.] Corrosive, causes eye and skin damage [or skin irritation]. Do not get in eyes on skin, or on...
40 CFR 156.70 - Precautionary statements for human hazards.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., dermal, inhalation toxicity) Irritation effects (skin and eye) Sensitizer (There are no categories of... or spray mist]. Do not get in eyes, on skin, or on clothing. [Front panel first aid statement required.] Corrosive, causes eye and skin damage [or skin irritation]. Do not get in eyes on skin, or on...
Shim, Kyudae; Abdellatif, Mohamed; Choi, Eunsoo; Kim, Dongkyun
2017-04-01
The safety and effectiveness of antimicrobial ZnO films must be established for general applications. In this study, the antimicrobial activity, skin irritation, elution behavior, and mechanical properties of nanostructured ZnO films on stainless steel were evaluated. ZnO nanoparticle (NP) and ZnO nanowall (NW) structures were prepared with different surface roughnesses, wettability, and concentrations using an RF magnetron sputtering system. The thicknesses of ZnO NP and ZnO NW were approximately 300 and 620 nm, respectively, and ZnO NW had two diffraction directions of [0002] and [01-10] based on high-resolution transmission electron microscopy. The ZnO NW structure demonstrated 99.9% antimicrobial inhibition against Escherichia coli, Staphylococcus aureus, and Penicillium funiculosum, and no skin irritation was detected using experimental rabbits. Approximately 27.2 ± 3.0 μg L -1 Zn ions were eluted from the ZnO NW film at 100 °C for 24 h, which satisfies the WHO guidelines for drinking water quality. Furthermore, the Vickers hardness and fracture toughness of ZnO NW films on stainless steel were enhanced by 11 and 14% compared to those of the parent stainless steel. Based on these results, ZnO NW films on STS316L sheets are useful for household supplies, such as water pipes, faucets, and stainless steel containers.
Kilo, Sonja; Zonnur, Nina; Uter, Wolfgang; Göen, Thomas; Drexler, Hans
2015-10-01
Occupational exposure to carbon disulfide (CS2) leads to inhalative and dermal uptake and thereby to internal exposure. In order to prevent occupational contact dermatitis, gloves and skin protection creams are used at the workplace. The aim of the study was the evaluation of the influence of personal skin protection and irritation on the internal exposure to CS2 of employees in the viscose industry. One hundred and eighty-two male CS2-exposed employees were included in the study and were examined regarding working conditions, use of personal protective measures und skin status. Personal air monitoring and biological monitoring was performed and the 'relative internal exposure' (RIE, internal exposure in relation to external exposure) calculated. A multiple regression analysis calculated the influence of skin protection and irritation on CS2 uptake. Usage of skin protection creams and gloves (and both in combination) while working was associated with a significantly higher RIE indicating a higher dermal penetration of CS2. Equally, irritated skin and younger age was associated with a higher internal burden. Gloves and skin protection creams are useful for preventing occupational skin diseases. However, when handling skin-resorptive substances like CS2, they can increase internal exposure or skin irritation. Therefore, we recommend the careful consideration of benefits and risks of protective creams and gloves at the workplace. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
[Non-pharmacologic management of rosacea].
Borelli, C; Korting, H C
2011-11-01
Rosacea is like no other disease a problem for patients regarding the use of skin care and cleaning products. The subjective assessment of the severity of the illness is an important factor regarding the development of depression in these patients. Inadequate skin care and cleaning products can lead to irritation and stinging of the skin. Dermatologists should address questions regarding skin care, cleaning and sun screens. Because of the higher irritability of the skin of rosacea patients, all possibly irritating cleaning products or procedures should be avoided. The water temperature is also important; it should be lukewarm to avoid the provocation of a vascular reaction. Soaps should be avoided, because they are alkaline and thus lead to a higher pH of the skin. A higher pH of the skin can lead to irritation. Appropriate make-up causes no aggravation of the skin and increases patient's satisfaction with their skin and thus leads to a higher compliance with pharmacological therapy. Laser or intense pulsed light treatment can improve telangiectasia or erythema. Operative treatment of rhinophyma is effective and well-established.
Choi, Seunghye; Lee, Miri; Lee, Su-Hyon; Jung, Haeng-Sun; Kim, Seol-Yeong; Chung, Tae-Young; Choe, Tae-boo; Chun, Young-Jin; Lim, Kyung-Min
2015-09-01
Evaluation of the eye irritation is essential in the development of new cosmetic products. Draize rabbit eye irritation test has been widely used in which chemicals are directly applied to rabbit eye, and the symptoms and signs of eyes are scored. However, due to the invasive procedure, it causes substantial pain and discomfort to animals. Recently, we reported in vitro eye irritation test method using a 3D human corneal epithelial model (MCTT HCE™) which is reconstructed from remaining human tissues after a corneal transplantation. This model exhibited an excellent predictive capacity for 25 reference chemicals (sensitivity 100%, specificity 77% and accuracy 88% vs. GHS). To improve the test performance, we explored new biomarkers for the eye irritation through transcriptomic approach. Three surfactants were selected as model eye irritants that include sodium lauryl sulfate, benzalkonium chloride and triton X-100. After test chemicals were treated, we investigated differentially expressed genes through a whole-gene microarray (Affymetrix GeneChip(®) Human Gene 2.0 ST Array, 48,000 probes). As a result, we identified that mRNAs of cornifelin (CNFN), a constituent of the insoluble cornified cell envelope of stratified squamous epithelia, and early growth response-1 (EGR1), a nuclear transcriptional regulator, were significantly up-regulated by all three irritants. Up-regulation of CNFN and EGR1 was further confirmed by Q-RT-PCR, and immunohistochemistry revealed increased level of CNFN in irritant-treated tissues, supporting the relevance of CNFN and EGR1 as new biomarkers for eye irritation.
Farage, Miranda A; Meyer, Sandy; Walter, Dave
2004-05-01
The first main objective of the work presented in this paper was to investigate ways of optimizing the current arm patch test protocol by (1) increasing the sensitivity of the test in order to evaluate more effectively the products that are inherently non-irritating, and/or (2) reducing the costs of these types of studies by shortening the protocol. The second main objective was to use the results of these studies and the results of the parallel studies conducted using the behind-the-knee method to better understand the contribution of mechanical irritation to the skin effects produced by these types of products. In addition, we were interested in continuing the evaluation of sensory effects and their relationship to objective measures of irritation. Test materials were prepared from three, currently marketed feminine protection pads. Wet and dry samples were applied to the upper arm using the standard 24-h patch test. Applications were repeated daily for 4 consecutive days. The test sites were scored for irritation prior to the first patch application, and 30-60 min after removal of each patch. Some test sites were treated by tape stripping the skin prior to the initial patch application. In addition, in one experiment, panelists were asked to keep a daily diary describing any sensory skin effects they noticed at each test site. All protocol variations ([intact skin/dry samples], [compromised skin/dry samples], [intact skin/wet samples], and [compromised skin/wet samples]) gave similar results for the products tested. When compared to the behind-the-knee test method, the standard upper arm patch test gave consistently lower levels of irritation when the test sites were scored shortly after patch removal, even though the sample application was longer (24 vs. 6 h) in the standard patch test. The higher level of irritation in the behind-the-knee method was likely due to mechanical irritation. The sensory skin effects did not appear to be related to a particular test product or a particular protocol variation. However, the mean irritation scores at those sites where a sensory effect was reported were higher than the mean irritation scores at those sites were no sensory effects were reported. All four protocol variations of the standard upper arm patch test can be used to assess the inherent chemical irritant properties of feminine protection products. For these products, which are inherently non-irritating, tape stripping and/or applying wet samples does not increase the sensitivity of the patch test method. Differences in irritation potential were apparent after one to three 24-h applications. Therefore, the standard patch test protocol can be shortened to three applications without compromising our ability to detect differences in the chemical irritation produced by the test materials. The patch test can be used to evaluate effectively the inherent chemical irritation potential of these types of products. However, this method is not suitable for testing the mechanical irritation due to friction that occurs during product use. There is no relationship between specific test conditions, i.e., compromised skin and/or testing wet samples and reports of perceived sensory reactions. However, there seems to be a clear relationship between sensory reactions and objective irritation scores.
... body odor seborrhea (skin irritation) nasal irritation headache hot flashes insomnia change in weight vaginal dryness or vaginal discharge change in sex drive oily skin muscle aches rhinitis (runny nose) ...
Nizioł-Łukaszewska, Zofia; Osika, Paweł; Wasilewski, Tomasz; Bujak, Tomasz
2017-02-19
A significant problem related to the use of surfactants in body wash cosmetics is their propensity to trigger skin irritations. Only scarce literature exists on the effect of plant extracts on the skin irritation potential. The present study is an attempt to determine the effect of hydrophilic dogwood extracts on the irritant potential of body wash gels. Extractants used in the study were water and mixtures of water with glycerine, water with trimethylglycine (betaine), and water with plant-derived glycol (propanediol). The basic biochemical properties, i.e., the ability to neutralize free radicals, and the content of polyphenols, anthocyanins and flavonoids, were determined. An attempt was undertaken to analyze the impact of the extract added to natural body wash gel formulations on product properties. The skin irritation potential was assessed by determining the zein number and the increase in the pH level of the bovine serum albumin (BSA) solution. The viscosity and foaming ability of the resulting products were evaluated. The studies revealed that an addition of dogwood extract contributes to an improvement in the properties of body wash gels and significantly increases the safety of product use through reducing the skin irritation effect.
Yusof, Nor Zuliana; Abd Gani, Siti Salwa; Azizul Hasan, Zafarizal Aldrin; Idris, Zainab
2018-01-01
Many types of phytochemicals have been found to be present in oil palm leaf and could potentially be used as functional ingredients for skincare product. However, as of today, there is no published report on hazard identification and safety assessment of oil palm ( Elaeis guineensis) leaf extract (OPLE), particularly on skin and eye irritation. In this study, potential hazard of OPLE on skin and eye irritation was evaluated as an initial step to the safety assessment of OPLE. In vitro cell viability study of OPLE on normal human dermal fibroblasts showed that OPLE was nontoxic to the cells with percentage viability more than 90% after 24 and 48 hours of incubation. Skin irritation potential of OPLE was evaluated using in vitro SkinEthic reconstructed human epidermis (RHE) model (Organization for Economic Cooperation and Development [OECD] Test Guideline 439, 2015), while eye irritation potential was evaluated using in vitro SkinEthic Human corneal epithelium (HCE) model (OECD test guideline 492, 2017). Hazard identification results showed that OPLE at 1%, 5%, and 10% (wt/wt) was classified as nonirritant to the skin and eye where mean tissue viabilities of SkinEthic RHE and SkinEthic HCE were more than 50% and 60%, respectively. Therefore, we recommend a further safety assessment, such as human patch testing, to confirm the nonirritant of OPLE.
Filipović, Mila; Gledović, Ana; Lukić, Milica; Tasić-Kostov, Marija; Isailović, Tanja; Pantelić, Ivana; Vuleta, Gordana; Savić, Snežana
2016-11-01
Since skin moisturization may be achieved by both actives and chosen carrier, plant stem cells, squalene and natural alkyl polyglucoside emulsifier may be potential components of contemporary cosmetic products. The aim of the study was in vivo evaluation of the skin irritation potential and the efficacy of Alpine Rose stem cells incorporated into li-posomes and olive oil squalene as ingredients of moisturizing creams, with respect to the novel emulsifier used for creams’ stabilization. With the employment of noninvasive skin biophysical measurements, skin hydration (EC), transepi-dermal water loss (TEWL), erythema index (EI) and viscoelas-ticity were measured on 76 healthy volunteers. In the first phase, skin irritation after a 24-hour occlusion and the long-term efficacy of creams (a 21-day study) on healthy skin were evaluated. Phase II of the study focused on the cream efficacy assessment after a 6-day treatment of sodium lauryl sulfate-irritated skin. After a 24-hour occlusion, there were no significant changes in the EI for any tested sample. In the second phase of the study, the EI was not significantly altered for the cream containing squalene, while the application of all active samples resulted in a significant reduction of TEWL. In both phases of the study an EC increase was recorded, espe-cially for the squalene-containing cream. Due to the lack of skin irritation and skin barrier impairment along with the marked hydration effect, it could be said that the in-vestigated actives incorporated into alkyl polyglucoside emulsi-fier-stabilized creams may be safely applied as ingredients for "tailor-made" cosmetic moisturizers intended for normal and dry skin care, whereas olive oil squalene could be used for the treatment of irritated or sensitive skin as well. [Projekat Ministarstva nauke Republike Srbije, br. TR34031
Hoggarth, Andrew; Waring, Mike; Alexander, James; Greenwood, Amanada; Callaghan, Theresa
2005-12-01
In the treatment of incontinence dermatitis, a skin protectant primarily prevents skin breakdown due to moisture and biological irritants in urine and feces. To assess the barrier and skin hydration properties of six currently available skin protectants with different formulations, a controlled, three-phase study was conducted at a research facility in the UK among 18 healthy volunteers. The study addressed each product's efficacy against insult from a known irritant (sodium lauryl sulphate), skin hydration potential, and maintenance of skin barrier and barrier efficacy against maceration. Using white petrolatum (glycerin) as the positive control and untreated sites as the negative control, the results show that each one of the products tested has different performance properties. Products containing petrolatum demonstrated protection against irritants (P = 0.006 at 24 hours) and maceration (P < 0.005) and provided some skin hydration. Products containing dimethicone varied in protection against irritants (P < 0.005, or P > or = 0.806 at 24 hours) and have good skin hydration potential and low barrier efficacy (P > 0.500). Zinc oxide-based products showed protection against irritants (P < 0.005) but poor skin hydration and barrier properties to prevent maceration (P = 0.262). Overall, only the water-in-oil petrolatum- based product performed effectively within all the parameters tested. This study suggests that skin barrier protection involves more than the inclusion of an active barrier ingredient. Further testing and use of barrier products in the clinical setting will provide additional evidence for appropriate product selection.
Final report on the safety assessment of Ammonium, Potassium, and Sodium Persulfate.
Pang, S; Fiume, M Z
2001-01-01
Ammonium, Potassium, and Sodium Persulfate are inorganic salts used as oxidizing agents in hair bleaches and hair-coloring preparations. Persulfates are contained in hair lighteners at concentrations up to 60%, in bleaches and lighteners at up to 22% and 16%, respectively, and in off-the-scalp products used to highlight hair strands at up to 25%. They are used in professional product bleaches and lighteners at similar concentrations. Much of the available safety test data are for Ammonium Persulfate, but these data are considered applicable to the other salts as well. Acute dermal, oral, and inhalation toxicity studies are available, but only the latter are remarkable, with gross lesions observed in the lungs, liver, stomach, and spleen. In short-term and subchronic feeding studies the results were mixed; some studies found no evidence of toxicity and others found local damage to the mucous membrane in the gastrointestinal tract, but no other systemic effects. Short-term inhalation toxicity was observed when rats were exposed to aerosolized Ammonium Persulfate at concentrations of 4 mg/m3 and greater. Ammonium Persulfate (as a moistened powder) was not an irritant to intact rabbit skin, but was sensitizing (in a saline solution) to the guinea pig. It was slightly irritating to rabbit eyes. Ammonium Persulfate was negative in the Ames test and the chromosomal aberration test. No significant evidence of tumor promotion or carcinogenicity was observed in studies of rats receiving topical applications of Ammonium Persulfate. The persulfates were reported to cause both delayed-type and immediate skin reactions, including irritant dermatitis, allergic eczematous dermatitis, localized contact urticaria, generalized urticaria, rhinitis, asthma, and syncope. The most common causes of allergic dermatitis in hairdressers are the active ingredients in hair dyes, and Ammonium Persulfate has been identified as a frequent allergen. A sensitization study that also examined the incidence of urticarial reactions was performed with 17.5% Ammonium, Potassium, and Sodium Persulfate under occlusive patches. At this concentration and exposure conditions, a mixture of these Persulfates was not sensitizing, and application of Ammonium, Potassium, and Sodium Persulfate did not result in an urticarial reaction. In normal use (i.e., not occluded and rinsed off), it was expected that a concentration greater than 17.5% would also be safe. Given the clinical reports of urticarial reactions, however, manufacturers and formulators should be aware of the potential for urticarial reactions at concentrations of Persulfates greater than 17.5%. Based on the available data, the Cosmetic Ingredient Review (CIR) Expert Panel concluded that Ammonium, Potassium, and Sodium Persulfate are safe as used as oxidizing agents in hair colorants and lighteners designed for brief discontinuous use followed by thorough rinsing from the hair and skin.
Significance of hair-dye base-induced sensory irritation.
Fujita, F; Azuma, T; Tajiri, M; Okamoto, H; Sano, M; Tominaga, M
2010-06-01
Oxidation hair-dyes, which are the principal hair-dyes, sometimes induce painful sensory irritation of the scalp caused by the combination of highly reactive substances, such as hydrogen peroxide and alkali agents. Although many cases of severe facial and scalp dermatitis have been reported following the use of hair-dyes, sensory irritation caused by contact of the hair-dye with the skin has not been reported clearly. In this study, we used a self-assessment questionnaire to measure the sensory irritation in various regions of the body caused by two model hair-dye bases that contained different amounts of alkali agents without dyes. Moreover, the occipital region was found as an alternative region of the scalp to test for sensory irritation of the hair-dye bases. We used this region to evaluate the relationship of sensitivity with skin properties, such as trans-epidermal water loss (TEWL), stratum corneum water content, sebum amount, surface temperature, current perception threshold (CPT), catalase activities in tape-stripped skin and sensory irritation score with the model hair-dye bases. The hair-dye sensitive group showed higher TEWL, a lower sebum amount, a lower surface temperature and higher catalase activity than the insensitive group, and was similar to that of damaged skin. These results suggest that sensory irritation caused by hair-dye could occur easily on the damaged dry scalp, as that caused by skin cosmetics reported previously.
AbstractDermal exposure to metals may res·ult in irritant contact dermatitis. This study examined the potential of metal nanoparticles to elicit irritant contact dermatitis in a human skin equivalent model (HSEM) derived from epidermal keratinocytes. These cultured cells form a m...
... rash is an area of irritated or swollen skin. Many rashes are itchy, red, painful, and irritated. ... also lead to blisters or patches of raw skin. Rashes are a symptom of many different medical ...
A new alternative method for testing skin irritation using a human skin model: a pilot study.
Miles, A; Berthet, A; Hopf, N B; Gilliet, M; Raffoul, W; Vernez, D; Spring, P
2014-03-01
Studies assessing skin irritation to chemicals have traditionally used laboratory animals; however, such methods are questionable regarding their relevance for humans. New in vitro methods have been validated, such as the reconstructed human epidermis (RHE) model (Episkin®, Epiderm®). The comparison (accuracy) with in vivo results such as the 4-h human patch test (HPT) is 76% at best (Epiderm®). There is a need to develop an in vitro method that better simulates the anatomo-pathological changes encountered in vivo. To develop an in vitro method to determine skin irritation using human viable skin through histopathology, and compare the results of 4 tested substances to the main in vitro methods and in vivo animal method (Draize test). Human skin removed during surgery was dermatomed and mounted on an in vitro flow-through diffusion cell system. Ten chemicals with known non-irritant (heptylbutyrate, hexylsalicylate, butylmethacrylate, isoproturon, bentazon, DEHP and methylisothiazolinone (MI)) and irritant properties (folpet, 1-bromohexane and methylchloroisothiazolinone (MCI/MI)), a negative control (sodiumchloride) and a positive control (sodiumlaurylsulphate) were applied. The skin was exposed at least for 4h. Histopathology was performed to investigate irritation signs (spongiosis, necrosis, vacuolization). We obtained 100% accuracy with the HPT model; 75% with the RHE models and 50% with the Draize test for 4 tested substances. The coefficients of variation (CV) between our three test batches were <0.1, showing good reproducibility. Furthermore, we reported objectively histopathological irritation signs (irritation scale): strong (folpet), significant (1-bromohexane), slight (MCI/MI at 750/250ppm) and none (isoproturon, bentazon, DEHP and MI). This new in vitro test method presented effective results for the tested chemicals. It should be further validated using a greater number of substances; and tested in different laboratories in order to suitably evaluate reproducibility. Copyright © 2013 Elsevier Ltd. All rights reserved.
DERMATOLOGIC CHANGES IN THE CIRCUMILEOSTOMY SKIN
McNamara, Robert J.; Farber, Eugene M.; Roland, Samuel I.
1959-01-01
A comprehensive questionnaire inquiring about difficulties with care of the skin in the area immediately surrounding the artificial anus was sent to ileostomy patients in the United States. Eighty per cent of 327 replying to the questionnaire had such difficulties. The problem of irritation is essentially that of intimate contact of fecal material with the circumileostomy skin, and associated factors are the potentially irritating materials used in the manufacture of ileostomy appliances, as well as the adhesives used to affix the appliance to the skin. Mechanical trauma incident to removal and reapplication of the appliance, as well as loosening of the disc and exposure of unprotected skin, accelerates the corrosive action of the material discharged. Changing the appliance before leakage or irritation occurs is helpful in preventing skin difficulties. In cases of long standing or repeated irritation, care must be taken to check the suitability of the appliance or the possibility of a complication in the stoma that could be corrected surgically. ImagesFigure 2.Figure 4. PMID:13662859
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kosten, Ilona J.; Spiekstra, Sander W.; Gruijl, Tanja D. de
After allergen or irritant exposure, Langerhans cells (LC) undergo phenotypic changes and exit the epidermis. In this study we describe the unique ability of MUTZ-3 derived Langerhans cells (MUTZ-LC) to display similar phenotypic plasticity as their primary counterparts when incorporated into a physiologically relevant full-thickness skin equivalent model (SE-LC). We describe differences and similarities in the mechanisms regulating LC migration and plasticity upon allergen or irritant exposure. The skin equivalent consisted of a reconstructed epidermis containing primary differentiated keratinocytes and CD1a{sup +} MUTZ-LC on a primary fibroblast-populated dermis. Skin equivalents were exposed to a panel of allergens and irritants. Topicalmore » exposure to sub-toxic concentrations of allergens (nickel sulfate, resorcinol, cinnamaldehyde) and irritants (Triton X-100, SDS, Tween 80) resulted in LC migration out of the epidermis and into the dermis. Neutralizing antibody to CXCL12 blocked allergen-induced migration, whereas anti-CCL5 blocked irritant-induced migration. In contrast to allergen exposure, irritant exposure resulted in cells within the dermis becoming CD1a{sup −}/CD14{sup +}/CD68{sup +} which is characteristic of a phenotypic switch of MUTZ-LC to a macrophage-like cell in the dermis. This phenotypic switch was blocked with anti-IL-10. Mechanisms previously identified as being involved in LC activation and migration in native human skin could thus be reproduced in the in vitro constructed skin equivalent model containing functional LC. This model therefore provides a unique and relevant research tool to study human LC biology in situ under controlled in vitro conditions, and will provide a powerful tool for hazard identification, testing novel therapeutics and identifying new drug targets. - Highlights: • MUTZ-3 derived Langerhans cells integrated into skin equivalents are fully functional. • Anti-CXCL12 blocks allergen-induced MUTZ-LC migration. • Anti-CCL5 blocks irritant-induced MUTZ-LC migration. • Irritant mediated MUTZ-LC trans-differentiation to macrophage-like cell in dermis. • Trans-differentiation of MUTZ-LC is IL-10 dependent.« less
Horita, Kotomi; Horita, Daisuke; Tomita, Hiroyuki; Yasoshima, Mitsue; Yagami, Akiko; Matsunaga, Kayoko
2017-05-01
Animal testing for cosmetics was banned in the European Union (EU) in 2013; therefore, human tests to predict and ensure skin safety such as the patch test or usage test are now in demand in Japan as well as in the EU. In order to investigate the effects of different bases on the findings of tests to predict skin irritation, we performed patch testing (PT) and the repeated application test (RAT) using sodium lauryl sulfate (SLS), a well-known irritant, dissolved in 6 different base agents to examine the effects of these bases on skin irritation by SLS. The bases for PT were distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream. The concentrations of SLS were 0.2% and 0.5%. Twelve different base combinations were applied to the normal back skin of 19 individuals for 24h. RAT was performed with distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream containing SLS at concentrations of 0.2%, 2%, and 5%, being applied to the arms of the same PT subjects. The test preparation of each base was applied at the same site, with 0.2% SLS being used in the first week, 2% SLS in the following week, and 5% SLS in the final week. The results of PT revealed that skin irritation scores varied when SLS at the same concentration was dissolved in a different base. The results of RAT showed that although skin irritation appeared with every base at a concentration of 5%, the positive rate was approximately the same. In conclusion, our results suggest that skin irritation elicited in PT depends on the base, while in RAT, it does not depend on the type of base employed. Copyright © 2017 Elsevier B.V. All rights reserved.
... skin reactions when using latex. They include: Allergic contact dermatitis. This reaction results from the chemical additives used ... hours after exposure, similar to poison ivy. Irritant contact dermatitis. Not an allergy, this skin irritation is caused ...
Stratum corneum cytokines and skin irritation response to sodium lauryl sulfate.
De Jongh, Cindy M; Verberk, Maarten M; Withagen, Carien E T; Jacobs, John J L; Rustemeyer, Thomas; Kezic, Sanja
2006-06-01
Little is known about cytokines involved in chronic irritant contact dermatitis. Individual cytokine profiles might explain at least part of the differences in the individual response to irritation. Our objective was to investigate the relation between baseline stratum corneum (SC) cytokine levels and the skin response to a single and a repeated irritation test. This study also aimed to determine changes in SC cytokine levels after repeated irritation. Transepidermal water loss (TEWL) and erythema were measured in 20 volunteers after single 24-hr exposure to 1% sodium lauryl sulfate (SLS), and during and after repeated exposure to 0.1% SLS over a 3-week period. SC cytokine levels were measured from an unexposed skin site and from the repeatedly exposed site. Interleukin (IL)-1alpha decreased by 30% after repeated exposure, while IL-1RA increased 10-fold and IL-8 increased fourfold. Baseline IL-1RA and IL-8 values were predictors of TEWL and erythema after single exposure (r = 0.55-0.61). 6 subjects showed barrier recovery during repeated exposure. Baseline IL-1RA and IL-8 levels are likely to be indicators of higher skin irritability after single exposure to SLS. Barrier repair in some of the subjects might explain the lack of agreement between the TEWL response after single and repeated irritation.
2003-01-01
Salicylic Acid is an aromatic acid used in cosmetic formulations as a denaturant, hair-conditioning agent, and skin-conditioning agent--miscellaneous in a wide range of cosmetic products at concentrations ranging from 0.0008% to 3%. The Calcium, Magnesium, and MEA salts are preservatives, and Potassium Salicylate is a cosmetic biocide and preservative, not currently in use. Sodium Salicylate is used as a denaturant and preservative (0.09% to 2%). The TEA salt of Salicylic Acid is used as an ultraviolet (UV) light absorber (0.0001% to 0.75%). Several Salicylic Acid esters are used as skin conditioning agents--miscellaneous (Capryloyl, 0.1% to 1%; C12-15 Alkyl, no current use; Isocetyl, 3% to 5%; Isodecyl, no current use; and Tridecyl, no current use). Butyloctyl Salicylate (0.5% to 5%) and Hexyldodecyl Salicylate (no current use) are hair-conditioning agents and skin-conditioning agents--miscellaneous. Ethylhexyl Salicylate (formerly known as Octyl Salicylate) is used as a fragrance ingredient, sunscreen agent, and UV light absorber (0.001% to 8%), and Methyl Salicylate is used as a denaturant and flavoring agent (0.0001% to 0.6%). Myristyl Salicylate has no reported function. Isodecyl Salicylate is used in three formulations, but no concentration of use information was reported. Salicylates are absorbed percutaneously. Around 10% of applied salicylates can remain in the skin. Salicylic Acid is reported to enhance percutaneous penetration of some agents (e.g., vitamin A), but not others (e.g., hydrocortisone). Little acute toxicity (LD(50) in rats; >2 g/kg) via a dermal exposure route is seen for Salicylic Acid, Methyl Salicylate, Tridecyl Salicylate, and Butyloctyl Salicylate. Short-term oral, inhalation, and parenteral exposures to salicylates sufficient to produce high blood concentrations are associated primarily with liver and kidney damage. Subchronic dermal exposures to undiluted Methyl Salicylate were associated with kidney damage. Chronic oral exposure to Methyl Salicylate produced bone lesions as a function of the level of exposure in 2-year rat studies; liver damage was seen in dogs exposed to 0.15 g/kg/day in one study; kidney and liver weight increases in another study at the same exposure; but no liver or kidney abnormalities in a study at 0.167 g/kg/day. Applications of Isodecyl, Tridecyl, and Butyloctyl Salicylate were not irritating to rabbit skin, whereas undiluted Ethylhexyl Salicylate produced minimal to mild irritation. Methyl Salicylate at a 1% concentration with a 70% ethanol vehicle were irritating, whereas a 6% concentration in polyethylene glycol produced little or no irritation. Isodecyl Salicylate, Methyl Salicylate, Ethylhexyl (Octyl) Salicylate, Tridecyl Salicylate, and Butyloctyl Salicylate were not ocular irritants. Although Salicylic Acid at a concentration of 20% in acetone was positive in the local lymph node assay, a concentration of 20% in acetone/olive oil was not. Methyl Salicylate was negative at concentrations up to 25% in this assay, independent of vehicle. Maximization tests of Methyl Salicylate, Ethylhexyl Salicylate, and Butyloctyl Salicylate produced no sensitization in guinea pigs. Neither Salicylic Acid nor Tridecyl Salicylate were photosensitizers. Salicylic Acid, produced when aspirin is rapidly hydrolyzed after absorption from the gut, was reported to be the causative agent in aspirin teratogenesis in animals. Dermal exposures to Methyl Salicylate, oral exposures to Salicylic Acid, Sodium Salicylate, and Methyl Salicylate, and parenteral exposures to Salicylic Acid, Sodium Salicylate, and Methyl Salicylate are all associated with reproductive and developmental toxicity as a function of blood levels reached as a result of exposure. An exposure assessment of a representative cosmetic product used on a daily basis estimated that the exposure from the cosmetic product would be only 20% of the level seen with ingestion of a "baby" aspirin (81 mg) on a daily basis. Studies of the genotoxic potential of Salicylic Acid, Sodium Salicylate, Isodecyl Salicylate, Methyl Salicylate, cosmetic product would be only 20% of the level seen with ingestion of a "baby" aspirin (81 mg) on a daily basis. Studies of the genotoxic potential of Salicylic Acid, Sodium Salicylate, Isodecyl Salicylate, Methyl Salicylate, Ethylhexyl (Octyl) Salicylate, Tridecyl Salicylate, and Butyloctyl Salicylate were generally negative. Methyl Salicylate, in a mouse skin-painting study, did not induce neoplasms. Likewise, Methyl Salicylate was negative in a mouse pulmonary tumor system. In clinical tests, Salicylic Acid (2%) produced minimal cumulative irritation and slight or no irritation(1.5%); TEA-Salicylate (8%) produced no irritation; Methyl Salicylate (>12%) produced pain and erythema, a 1% aerosol produced erythema, but an 8% solution was not irritating; Ethylhexyl Salicylate (4%) and undiluted Tridecyl Salicylate produced no irritation. In atopic patients, Methyl Salicylate caused irritation as a function of concentration (no irritation at concentrations of 15% or less). In normal skin, Salicylic Acid, Methyl Salicylate, and Ethylhexyl (Octyl) Salicylate are not sensitizers. Salicylic Acid is not a photosensitizer, nor is it phototoxic. Salicylic Acid and Ethylhexyl Salicylate are low-level photoprotective agents. Salicylic Acid is well-documented to have keratolytic action on normal human skin. Because of the possible use of these ingredients as exfoliating agents, a concern exists that repeated use may effectively increase exposure of the dermis and epidermis to UV radiation. It was concluded that the prudent course of action would be to advise the cosmetics industry that there is a risk of increased UV radiation damage with the use of any exfoliant, including Salicylic Acid and the listed salicylates, and that steps need to be taken to formulate cosmetic products with these ingredients as exfoliating agents so as not to increase sun sensitivity, or when increased sun sensitivity would be expected, to include directions for the daily use of sun protection. The available data were not sufficient to establish a limit on concentration of these ingredients, or to identify the minimum pH of formulations containing these ingredients, such that no skin irritation would occur, but it was recognized that it is possible to formulate cosmetic products in a way such that significant irritation would not be likely, and it was concluded that the cosmetics industry should formulate products containing these ingredients so as to be nonirritating. Although simultaneous use of several products containing Salicylic Acid could produce exposures greater than would be seen with use of baby aspirin (an exposure generally considered to not present a reproductive or developmental toxicity risk), it was not considered likely that consumers would simultaneously use multiple cosmetic products containing Salicylic Acid. Based on the available information, the Cosmetic Ingredient Review Expert Panel reached the conclusion that these ingredients are safe as used when formulated to avoid skin irritation and when formulated to avoid increasing the skin's sun sensitivity, or, when increased sun sensitivity would be expected, directions for use include the daily use of sun protection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brodsky, Berta; Erlanger-Rosengarten, Avigail; Proscura, Elena
2008-06-15
The primary purpose of the present study was to investigate the mechanism of the counter-irritating activity of topical iodine against skin lesions induced by chemical and thermal stimuli. The hypothesis that iodine exerts its activity by inducing an endogenous anti-inflammatory factor was confirmed by exposing guinea pig skin to heat stimulus followed by topical iodine treatment and skin extraction. Injection of the extract into naive guinea pigs reduced heat-induced irritation by 69%. The protective factor, identified as a new nonapeptide (histone H2A 36-44, H-Lys-Gly-Asn-Tyr-Ala-Glu-Arg-Ileu-Ala-OH), caused reduction of 40% in irritation score in heat-exposed guinea pigs. The murine analog (H-Lys-Gly-His-Tyr-Ala-Glu-Arg-Val-Gly-OH, termedmore » IIIM1) reduced sulfur mustard (SM)-induced ear swelling at a dose-dependent bell-shape manner reaching peak activity of 1 mg/kg. Cultured keratinocytes transfected with the peptide were more resistant towards SM than the control cells. The peptide suppressed oxidative burst in activated neutrophils in a concentration-dependent manner. In addition, the peptide reduced glucose oxidase-induced skin edema in mice at a dose-dependent bell-shape manner. Apart from thermal and chemical-induced skin irritation this novel peptide might be of potential use in chronic dermal disorders such as psoriasis and pemphigus as well as non-dermal inflammatory diseases like multiple sclerosis, arthritis and colitis.« less
Kano, Satoshi; Sugibayashi, Kenji
2006-02-01
The aim of this study was to kinetically and dynamically analyze in vitro cytotoxicity as an index of skin irritation by use of a three-dimensional cultured human skin model and to compare the in vitro assay data with data from living animals. A cationic surfactant, cetylpyridinium chloride (CPC), was selected as a model irritant. Living skin equivalent-high (LSE-high) and hairless mice were used for the in vitro and in vivo tests, respectively. Skin irritation dermatodynamics was evaluated by calorimetric thiazoyl blue (MTT) conversion assay both for in vitro and in vivo tests, whereas dermatokinetics of CPC in LSE-high and mouse skin were evaluated using HPLC. The time course of cell viability in the skin after application of CPC to intact skin was distinctly different from that of stratum-corneum-stripped skin in both LSE-high and hairless mice. Biphasic behavior characterized by two first-order rates with an inflection time point was observed in intact skin, whereas cell viability monoexponentially decreased immediately after CPC application in stripped skin. The time courses of cell viability in the skin and dermatodynamics were closely related to that of dermatokinetics of CPC. The present study demonstrates that the in vitro cytotoxic profile was similar to the in vivo cytotoxicity test and that dermatodynamics was related to dermatokinetics of CPC.
Correlation between pH and irritant effect of cleansers marketed for dry skin.
Baranda, Lourdes; González-Amaro, Roberto; Torres-Alvarez, Bertha; Alvarez, Carmen; Ramírez, Victoria
2002-08-01
Although it is important that dermatologists and the general population know the irritation potential of products marketed for dry skin used for body cleansing, this information is not usually available. To assess the irritative effect of different soaps and liquid cleansers recommended for sensitive skin. To study the correlation of the irritation effect of each substance with its pH and with the presence or absence of syndet in the product. Seventeen products marketed for dry skin and 12 common soaps used by the general population were studied. Fresh soap emulsions (8%) were applied to the volar side of the right forearm of 30 individuals with sensitive skin for 5 consecutive days using aluminum chambers. The appearance of irritation (erythema, scaling and fissures) was recorded, scored, and expressed in an Irritation index (IrIn). The pH of each solution was measured. Products with a low IrIn were White Dove (Dove, Lever Pond's, Toronto, Ontario, Canada), Dove Baby, Cetaphil (bar) (Cetaphil, Gulderma Lab., Forth Worth, TX, USA), Dove liquid cleanser for hands, Dove pink, and Aderma (Adenma, Pierre Fabre, Dermo-Cosmetique, Boulagne, France). Most corresponded to syndet products. Among the most used brand-name soap, Camay Classic (Camay, Procter & Gamble de Mexico, México, U.F.) had the lowest IrIn. Dove Baby was the only product with a neutral pH. A significant correlation between pH and the IrIn of cleansers was found (P < 0.006). Most products recommended for sensitive skin have a considerable irritation effect, which is related to the pH of the product. Better regulation of advertisement specifications including the pH level and type of cleanser contained is necessary for the majority of soaps and cleansers.
76 FR 61587 - Prothioconazole; Pesticide Tolerances
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-05
... toxicity by oral, dermal, and inhalation routes. It is not a dermal sensitizer, or a skin or eye irritant... routes. It is not a dermal sensitizer, or a skin irritant, but it is a slight eye irritant. The... barley at 0.2 ppm; oats, rye, and wheat at 0.05 ppm each; in the fodder (dry) of cereal grains at 5 ppm...
[Grade IIb alkali burns of the lower extremities. Working with concrete].
Hasenecker, J M H; Ruchholtz, S; Eming, R; Frangen, T M
2014-01-01
The irritating effects of concrete (calcium oxide) on skin have long been known. The effect by long-term skin exposure is not only irritating but also erosive and alkali skin erosion may result due to colliquative skin necrosis. A complicated course may ensue potentially necessitating plastic reconstructive treatment due to the development of unstable scars and defects. Correct interpretation of the skin trauma and adequate treatment are mandatory for functional restitution.
1983-11-01
the control group and folliculitis with furunculosis was present in I female rabbit in the exposed group. Microscopic findings in each skin section, by...ulceration was present in 1/5 female control rabbits and folliculitis with furunculosis was present in 1/5 female rabbits exposed to SEX. Normal skin...dermatitis with ulceration and the folliculitis with furunculosis are either incidental findings or are due to the abrasion of the skin and/or
Nicander, Ingrid; Aberg, Peter; Ollmar, Stig
2003-02-01
Products containing detergents can damage the skin and give rise to irritant contact dermatitis. Therefore, attempts have been made to find less irritating detergents as well as substances decreasing undesired side-effects of detergents, and a novel approach is offered by betaine. The aim of the study has been to determine the irritating properties of some liquid soaps for personal hygiene and to map the effect of different concentrations of betaine using electrical impedance, trans-epidermal water loss and visual inspection. Twenty-eight healthy subjects were patch tested with different commercial soaps with and without betaine and sodium lauryl sulphate on both volar forearms for 24 h. A site with distilled water and an unoccluded area were used as references. Responses of the skin reactions were evaluated by visual inspection and by measuring trans-epidermal water loss and electrical impedance before application and 24 h after removal of the chambers. Significant skin reactions were found for all soaps tested but the soaps containing betaine were the least irritating. However, the skin irritation did not decrease with increasing concentrations of betaine in the tested range. On the whole the differences between the products were not large. The non-invasive methods used were more sensitive than visual assessment for evaluation of invisible or barely visible skin responses. Copyright Blackwell Munksgaard 2003
The role of skin barrier in occupational contact dermatitis.
Jakasa, Ivone; Thyssen, Jacob P; Kezic, Sanja
2018-06-12
Skin diseases represent one of the most common work-related diseases and may have a detrimental effect on social, personal and occupational aspects of life. Contact dermatitis, which comprises predominately irritant contact dermatitis (ICD) and allergic contact dermatitis (ACD) accounts for vast majority of occupational skin diseases, especially in occupations associated with frequent skin contact with irritants and contact allergens. Although ICD and ACD have similar clinical manifestation, their pathophysiology and the role of the skin barrier is different. In ICD, perturbation of the skin barrier is the primary event which sets into motion diverse metabolic processes and triggers activation of innate immunity without involvement of adaptive immune system. In ACD, a type IV hypersensitivity reaction induced by contact allergens, the skin barrier impairment may evoke innate signaling pathways during the sensitization phase required for the activation of T-cell adaptive response. Thus, skin barrier impairment may increase the risk of ICD or ACD not only because of enhanced permeability and ingress of irritants and allergens, but also by generation of innate immune signal needed for the induction of allergic response. Hence, an efficient way to prevent CD is to avoid skin barrier damage in the workplace. This review focuses on the skin barrier, how it is affected by skin irritants and how its impairment contributes to development of ICD and ACD. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Agner, T
1992-01-01
The aim of the study was to assess the susceptibility of clinically normal skin to a standard irritant trauma under varying physiological and patophysiological conditions. Evaluation of skin responses to patch tests with sodium lauryl sulphate (SLS) was used for assessment of skin susceptibility. The following noninvasive measuring methods were used for evaluation of the skin before and after exposure to irritants: measurement of transepidermal water loss by an evaporimeter, measurement of electrical conductance by a hydrometer, measurement of skin blood flow by laser Doppler flowmetry, measurement of skin colour by a colorimeter and measurement of skin thickness by ultrasound A-scan. The studies were carried out on healthy volunteers and patients with eczema. In the first studies the standard irritant patch test for assessment of skin susceptibility was characterized and validated. SLS was chosen among other irritants because of its ability to penetrate and impair the skin barrier. The implications of use of different qualities of SLS was investigated. The applied noninvasive measuring methods were evaluated, and for quantification of SLS-induced skin damage measurement of TEWL was found to be the most sensitive method. Application of the standard test on clinically normal skin under varying physiological and patophysiological conditions lead to the following main results: Seasonal variation in skin susceptibility to SLS was found, with increased susceptibility in winter, when the hydration state of the stratum corneum was also found to be decreased. A variation in skin reactivity to SLS during the menstrual cycle was demonstrated, with an increased skin response at day 1 as compared to days 9-11 in the menstrual cycle. The presence of active eczema distant from the test site increased skin susceptibility to SLS, indicating a generalized hyperreactivity of the skin. Taking these sources of variation into account healthy volunteers and patients with hand eczema and atopic dermatits were studied and compared. In healthy volunteers increased baseline TEWL and increased light reflection from the skin, interpreted as "fair" skin, was found to be associated with increased susceptibility to SLS. Hand eczema patients were found to have fairer and thinner skin than matched controls. Increased susceptibility to SLS was found only in patients with acute eczema. Patients with atopic dermatitis had increased baseline TEWL as well as increased skin susceptibility as compared to controls. Skin susceptibility is thus influenced by individual- as well as environment-related factors. Knowledge of determinants of skin susceptibility may be useful for the identification of high-risk subjects for development of irritant contact dermatitis, and may help to prevent the formation of the disease.
Soliman, Sara M; Abdelmalak, Nevine S; El-Gazayerly, Omaima N; Abdelaziz, Nabaweya
2016-06-01
Proniosomes offer a versatile vesicle drug delivery concept with potential for delivery of drugs via transdermal route. To develop proniosomal gel using cremophor RH 40 as non-ionic surfactant containing the antihypertensive drug lacidipine for transdermal delivery so as to avoid its extensive first pass metabolism and to improve its permeation through the skin. Proniosomes containing 1% lacidipine were prepared by the coacervation phase separation method, characterized, and optimized using a 2(3) full factorial design to define the optimum conditions to produce proniosomes with high entrapment efficiency, minimal vesicle size, and high-percentage release efficiency. The amount of cholesterol (X1), the amount of soya lecithin (X2), and the amount of cremophor RH 40 (X3) were selected as three independent variables. The system F4 was found to fulfill the maximum requisite of an optimum system because it had minimum vesicle size, maximum EE, maximum release efficiency, and maximum desirability. The optimized system (F4) was then converted to proniosomal gel using carbopol 940 (1% w/w). In vitro permeation through excised rabbit skin study revealed higher flux (6.48 ± 0.45) for lacidipine from the optimized proniosomal gel when compared with the corresponding emulgel (3.04 ± 0.13) mg/cm(2)/h. The optimized formulation was evaluated for its bioavailability compared with commercial product. Statistical analysis revealed significant increase in AUC (0 - α) 464.17 ± 113.15 ng h/ml compared with 209.02 ± 47.35 ng h/ml for commercial tablet. Skin irritancy and histopathological investigation of rat skin revealed its safety. Cremophor RH 40 proniosomal gel could be considered as very promising nanocarriers for transdermal delivery of lacidipine.
NEUROPEPTIDE MODULATION OF CHEMICALLY INDUCED SKIN IRRITATION
This study was designed to demonstrate that the early symptoms of chemically-induced skin irritation are neurally mediated. everal approaches were used to affect nerve transmission in adult Balb/c female mice. hese included general anesthesia (i.e., sodium pentobarbital), systemi...
[Incidence of irritant dermatosis among employees of the shipbuilding industry].
Heise, H; Kühne, G; Kröger, D
1983-10-01
Irritant dermatosis is a non-specific reactive change on the skin. In most cases it represents the summated effects induced by various agents. Not only the shortened recovery phases of the skin but also a dispositional factor are important. Such changes, which are relatively common in some vocations but are usually only slight, cannot, as a rule, be regarded as signs of illness. Nevertheless, attention should be drawn to the necessity of intensive skin care and observation of the recovery phases because the frequency of irritant dermatosis can increase with increasing length of employment.
Selleri, Paolo; Di Girolamo, Nicola; Vögtlin, Andrea; Fileccia, Ivan; Hoop, Richard; Bongiovanni, Laura
2014-12-01
A novel bivalent vaccine to protect against myxomatosis and rabbit haemorrhagic disease is commercially available for pet rabbits. To describe the appearance of cutaneous lesions arising in pet rabbits positive for myxoma virus (MV) by RT-PCR evaluation shortly after vaccination. Four pet rabbits presenting with papular, crusting skin lesions ~10 days after vaccination. Histological evaluation of formalin-fixed skin biopsies obtained from lesional skin (case 1). Real-time polymerase chain reaction (RT-PCR) evaluation of paraffin-embedded tissue from skin biopsies (case 1) and crusts obtained from the lesion surface (cases 2-4) for myxoma virus are reported as cycle threshold (Ct ) values. Lesions affecting the ear pinna, dorsal aspect of the nose, vulva and/or conjunctiva are reported. Histopathological findings included severe ulcerative, necrotizing dermatitis and intralesional cytoplasmic inclusion bodies in myxoma cells. DNA was amplified from all the paraffin-embedded skin biopsies (Ct = 34-35) and crusts (Ct = 20-24). Although a wild virus challenge cannot be definitively excluded, veterinarians and pet-owners should be aware that cutaneous lesions have been observed after vaccination with this novel vaccine in low numbers of rabbits. © 2014 ESVD and ACVD.
Final report on the safety assessment of triacetin.
Fiume, Monice Zondlo
2003-01-01
Triacetin, also known as Glyceryl Triacetate, is reported to function as a cosmetic biocide, plasticizer, and solvent in cosmetic formulations, at concentrations ranging from 0.8% to 4.0%. It is a commonly used carrier for flavors and fragrances. Triacetin was affirmed as a generally recognized as safe (GRAS) human food ingredient by the Food and Drug Administration (FDA). Triacetin was not toxic to animals in acute oral or dermal exposures, nor was it toxic in short-term inhalation or parenteral studies, and subchronic feeding and inhalation studies. Triacetin was, at most, slightly irritating to guinea pig skin. However, in one study, it caused erythema, slight edema, alopecia, and desquamation, and did cause some irritation in rabbit eyes. Triacetin was not sensitizing in guinea pigs. Triacetin was not an irritant or a sensitizer in a clinical maximization study, and only very mild reactions were seen in a Duhring-chamber test using a 50% dilution. In humans, Triacetin reportedly has caused ocular irritation but no injury. Triacetin was not mutagenic. Although there were no available reproductive and developmental toxicity data, Triacetin was quickly metabolized to glycerol and acetic acid and these chemicals were not developmental toxins. Reports of 1,2-glyceryl diesters, which may be present in Triacetin, affecting cell growth and proliferation raised the possibility of hyperplasia and/or tumor promotion. The Cosmetic Ingredient Review (CIR) Expert Panel concluded, however, that the effects of 1,2-glyceryl diesters on cell growth and proliferation require longer ester chains on the glycerin backbone than are present when acetic acid is esterified with glycerin, as in Triacetin. On the basis of the available information, the CIR Expert Panel concluded that Triacetin is safe as used in cosmetic formulations.
Effect of interstitial low level laser stimulation in skin density
NASA Astrophysics Data System (ADS)
Jang, Seulki; Ha, Myungjin; Lee, Sangyeob; Yu, Sungkon; Park, Jihoon; Radfar, Edalat; Hwang, Dong Hyun; Lee, Han A.; Kim, Hansung; Jung, Byungjo
2016-03-01
As the interest in skin was increased, number of studies on skin care also have been increased. The reduction of skin density is one of the symptoms of skin aging. It reduces elasticity of skin and becomes the reason of wrinkle formation. Low level laser therapy (LLLT) has been suggested as one of the effective therapeutic methods for skin aging as in hasten to change skin density. This study presents the effect of a minimally invasive laser needle system (MILNS) (wavelength: 660nm, power: 20mW) in skin density. Rabbits were divided into three groups. Group 1 didn't receive any laser stimulation as a control group. Group 2 and 3 as test groups were exposed to MILNS with energy of 8J and 6J on rabbits' dorsal side once a week, respectively. Skin density of rabbits was measured every 12 hours by using an ultrasound skin scanner.
A study of the relationship between susceptibility to skin stinging and skin irritation.
Basketter, D A; Griffiths, H A
1993-10-01
In an evaluation of the safety of new chemicals, of products containing them, or of novel formulations of existing chemicals which may come into contact with the skin, it is important to incorporate an assessment of specially susceptible sub-populations. Such a group is represented by those who are more likely to experience sensory effects such as stinging. Since these individuals are easily and rapidly identifiable, we investigated whether they represented a group who were also more susceptible to the effects of an irritant. The primary purpose was to discover whether 'stingers' might represent an easily and rapidly identifiable sub-population with a more generally increased tendency to give skin responses. The response to a 0.3% sodium dodecyl sulphate patch test was assessed in a group of 25 'stingers' and compared to the response in 25 'non-stingers'. There was no difference in either the pattern or strength of the irritant response assessed by subjective erythema and dryness scores. Thus the data suggest that there is no correlation between the susceptibility of an individual to a skin stinging response and an irritation reaction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferrada, J.J.
2000-04-03
Public Law (PL) 105-204 requires the U.S. Department of Energy to develop a plan for inclusion in the fiscal year 2000 budget for conversion of the Department's stockpile of depleted uranium hexafluoride (DUF{sub 6}) to a more stable form over an extended period. The conversion process into a more stable form will produce fluorine compounds (e.g., elemental fluorine or hydrofluoric acid) that need to be handled safely. This document compiles the requirements necessary to handle these materials within health and safety standards, which may apply in order to ensure protection of the environment and the safety and health of workersmore » and the public. Fluorine is a pale-yellow gas with a pungent, irritating odor. It is the most reactive nonmetal and will react vigorously with most oxidizable substances at room temperature, frequently with ignition. Fluorine is a severe irritant of the eyes, mucous membranes, skin, and lungs. In humans, the inhalation of high concentrations causes laryngeal spasm and broncospasms, followed by the delayed onset of pulmonary edema. At sublethal levels, severe local irritation and laryngeal spasm will preclude voluntary exposure to high concentrations, unless the individual is trapped or incapacitated. A blast of fluorine gas on the shaved skin of a rabbit causes a second degree burn. Lower concentrations cause severe burns of insidious onset, resulting in ulceration, similar to the effects produced by hydrogen fluoride. Hydrofluoric acid is a colorless, fuming liquid or gas with a pungent odor. It is soluble in water with release of heat. Ingestion of an estimated 1.5 grams produced sudden death without gross pathological damage. Repeated ingestion of small amounts resulted in moderately advanced hardening of the bones. Contact of skin with anhydrous liquid produces severe burns. Inhalation of AHA or aqueous hydrofluoric acid mist or vapors can cause severe respiratory tract irritation that may be fatal. Based on the extreme chemical properties of these chemicals as noted above, fluorine or fluorine compounds must be handled appropriately within the boundaries of many safety requirements for the protection of the environment and the public. This report analyzes the safety requirements that regulatory agencies have issued to handle fluorine or fluorine compounds and lists them in Table 1. Table 1 lists the source of the requirements, the specific section of the source document, and a brief description of the requirements.« less
1983-08-16
reaction (w/v) Oil of Bergamot irritation reaction under test (positive control) in 95% under test conditions and is ethyl alcohol was conditions, not...the rabbits, 0.05 mL cation and irradiation of the test chemical, caused greater irritant positive control (oil of effects than in un- Bergamot ) and
Ethnic differences in objective and subjective skin irritation response: an international study.
Lee, E; Kim, S; Lee, J; Cho, S-A; Shin, K
2014-08-01
Due to global marketing in the cosmetics industry, it is important to assess ethnic population susceptibility when evaluating the safety of cosmetic products or chemicals. To investigate ethnic variations in skin irritation response to positive irritants. Clinical testing was performed in four countries on two ethnic groups - Asian and Caucasian. We performed patch tests on the subjects' back with 0.5% aqueous sodium lauryl sulfate (SLS) and 0.15% retinol prepared in 1,3-butylene glycol. Stinging tests were performed using 5% aqueous lactic acid and 0.001% (w/v) capsaicin prepared in 10% ethanol solution separately. The incidence of self-perceived skin sensitivity was similar in the two ethnic groups. However, the incidence of adverse skin reaction to cosmetics appeared significantly higher in Asian (33.0%) than in Caucasian subjects (11.3%). For standard positive irritants such as 0.5% aqueous SLS solution, Asian subjects showed significantly higher scores than Caucasian subjects. The incidence of positive reaction to the 0.15% retinol patch test tended to be higher in Asian than in Caucasian subjects. Our data also showed that neurosensitivity to 5% lactic acid and 0.001% capsaicin was higher in Asian than in Caucasian subjects. Although self-reported skin sensitivity does not appear to differ according to ethnicity, there are ethnic differences in objective and subjective skin irritation responses to several standard positive materials. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Snook, Tara S; White, Stephen D; Hawkins, Michelle G; Tell, Lisa A; Wilson, Laura S; Outerbridge, Catherine A; Ihrke, Peter J
2013-12-01
Rabbits are growing in popularity as companion animals, and dermatology problems are often the presenting complaint when seeing a veterinarian. To document skin diseases and their prevalence in pet domestic rabbits (Oryctolagus cuniculus) in northern California, USA; to investigate predilections for breed, age or sex for the most common conditions over a 20 year period. Three hundred and thirty-four pet rabbits from the overall hospital population met inclusion criteria. A retrospective study was carried out by searching the computerized medical records of rabbits seen at the Veterinary Medical Teaching Hospital (VMTH) from 1 January 1984 to 31 December 2004 using key words relevant to dermatology. Twenty-nine per cent of pet rabbits seen at the VMTH had skin disease. Lop-eared rabbits were over-represented, whereas mixed-breed rabbits and castrated males were under-represented in the dermatology caseload compared with the hospital population. Pododermatitis was the most common skin disease; abscesses, alopecia, otitis externa and ectoparasites also were common. Several species of bacteria other than Pasteurella spp. were isolated from abscesses. Despite the frequent mention of myxomatosis and venereal spirochetosis in the rabbit literature, few cases (three and two, respectively) were diagnosed. Castrated males were 3.7 times more likely to present with alopecia than intact males; rabbits <1 year of age were 3.6 times more likely to present with Psoroptes infestation/otitis than adult rabbits. Cutaneous conditions in pet rabbits in the USA are common. Bacterial culture should be performed and antibiotic susceptibility determined in all rabbits with abscesses, particularly those not responding to typical anti-Pasteurella antibiotics. © 2013 ESVD and ACVD.
Airborne irritant contact dermatitis due to synthetic fibres from an air-conditioning filter.
Patiwael, Jiska A; Wintzen, Marjolein; Rustemeyer, Thomas; Bruynzeel, Derk P
2005-03-01
We describe 8 cases of occupational airborne irritant contact dermatitis in intensive care unit (ICU) employees caused by synthetic (polypropylene and polyethylene) fibres from an air-conditioning filter. Not until a workplace investigation was conducted, was it possible to clarify the unusual sequence of events. High filter pressure in the intensive care air-conditioning system, maintained to establish an outward airflow and prevent microorganisms from entering the ward, probably caused fibres from the filter to become airborne. Upon contact with air-exposed skin, fibres subsequently provoked skin irritation. Test periods in the ICU with varying filter pressures, in an attempt to improve environmental conditions, led to even higher filter pressure levels and more complaints. The sometimes-very-low humidity might have contributed to development of skin irritation. The fact that most patients recovered quickly after treatment with emollients and changing the filters made it most likely that the airborne dermatitis was of an irritant nature.
Simion, F A; Rhein, L D; Morrison, B M; Scala, D D; Salko, D M; Kligman, A M; Grove, G L
1995-02-01
Epidemiologic studies indicate that after using soaps and other personal care products, many consumers experience irritation. In 50% of the cases the feelings of skin dryness, itching, and stinging occur in the absence of visible signs of irritation. We sought to determine the relation between self-perceived sensory responses of panelists to cleansing products and clinical signs of irritation. A combination of exaggerated arm-washing methods was designed to induce clinical signs of irritation with psychometric techniques developed to quantify sensations. Two studies demonstrated that panelists could reproducibly differentiate between products on the basis of the sensations they felt and that there was a significant correlation (frequently r > 0.80) between these and the observable signs. In the case of skin dryness panelists differentiated products several washing cycles before observable differences were detected. Sensory evaluations of irritation yield additional information on soap and detergent irritancy beyond clinical observations and expand understanding of the irritation process.
Pan, Lei; Liu, Yan; Wei, Qiang; Xiao, Chenwen; Ji, Quanan; Bao, Guolian; Wu, Xinsheng
2015-01-01
Background Fur is an important genetically-determined characteristic of domestic rabbits; rabbit furs are of great economic value. We used the Solexa sequencing technology to assess gene expression in skin tissues from full-sib Rex rabbits of different phenotypes in order to explore the molecular mechanisms associated with fur determination. Methodology/Principal Findings Transcriptome analysis included de novo assembly, gene function identification, and gene function classification and enrichment. We obtained 74,032,912 and 71,126,891 short reads of 100 nt, which were assembled into 377,618 unique sequences by Trinity strategy (N50=680 nt). Based on BLAST results with known proteins, 50,228 sequences were identified at a cut-off E-value ≥ 10-5. Using Blast to Gene Ontology (GO), Clusters of Orthologous Groups (KOG) and Kyoto Encyclopedia of Genes and Genomes (KEGG), we obtained several genes with important protein functions. A total of 308 differentially expressed genes were obtained by transcriptome analysis of plaice and un-plaice phenotype animals; 209 additional differentially expressed genes were not found in any database. These genes included 49 that were only expressed in plaice skin rabbits. The novel genes may play important roles during skin growth and development. In addition, 99 known differentially expressed genes were assigned to PI3K-Akt signaling, focal adhesion, and ECM-receptor interactin, among others. Growth factors play a role in skin growth and development by regulating these signaling pathways. We confirmed the altered expression levels of seven target genes by qRT-PCR. And chosen a key gene for SNP to found the differentially between plaice and un-plaice phenotypes rabbit. Conclusions/Significance The rabbit transcriptome profiling data provide new insights in understanding the molecular mechanisms underlying rabbit skin growth and development. PMID:25955442
Arshad, Atif I; Khan, Shoaib H M; Akhtar, Naveed; Mahmood, Asif; Sarfraz, Rai Muhammad
2016-01-01
The present investigation was conducted to evaluate non-invasively, various functional skin parameters i.e., irritation potential, melasma and sebum contents following long term application of topical cream (w/o) loaded with 2% methanolic extract of Ananas comosus L. versus placebo control (base) in healthy adults. Healthy human volunteers (n = 11, aged 20-30 years) were recruited for investigation and written informed consent was taken from each volunteer. In this single blinded study every volunteer applied formulation on one side of face and placebo on the other side of face twice daily for a period of 12 weeks (three months). Different skin parameters i.e., skin irritancy, melasma, and sebum contents were measured on both sides of face at baseline and after two weeks interval, using photometric device Mexameter and Sebumeter in a draught free room with modulated conditions of temperature (22-25°C) and humidity (55-60%). It was evident from the results that no primary skin irritancy was observed with patch test. Besides, statistical interpretation indicates that treatment with formulation is superior to placebo because it significantly (p ≤ 0.05) reduced the skin irritancy, melasma and sebum secretions throughout the study and reaching maximum -20.76 ± 0.89, -54.2 ± 0.37 and -40.71 ± 0.75%, respectively, at the end of study period. Antioxidant activity of extract was 92% compared to standard antioxidant. Conclusively, active cream loaded with fruit extract was well tolerated by all the volunteers and suitable to treat contact dermatitis, greasy skin, acne and seborrheic dermatitis and augmenting beauty and attraction by depigmentation of human skin. So, in the future, there is need to clinically evaluate these formulations in patients with compromised skin functions i.e., contact dermatitis, melasma, and acne vulgaris in order to explore the actual potential of this fruit.
Cutaneous tolerability to tretinoin shows little variation with Fitzpatrick skin type.
Webster, Guy F
2014-06-01
Determinants of skin irritability are poorly understood. This study aims to assess differences in cutaneous safety/irritation based on Fitzpatrick skin type among patients with acne treated with tretinoin gel microsphere (TGM). This was a phase 4, 12-week, prospective, nonrandomized, open-label, multicenter study. Approximately 500 patients with mild to moderate acne were treated with TGM 0.04% or 0.1% and assessed for cutaneous irritation at baseline and weeks 3, 6, and 12. In this post hoc analysis of patients with Fitzpatrick skin type I-III vs Fitzpatrick skin type IV-VI, there was a general trend toward initial worsening of cutaneous adverse events (AEs) by week 3 across all variables and groups. This was followed by a trend toward improvement and resolution of skin-related AEs from week 3 to week 12 regardless of Fitzpatrick skin type, with a few exceptions. Erythema was the only cutaneous AE that consistently decreased among patients with darker skin. Results from a subsequent 3-group analysis (Fitzpatrick I-II vs Fitzpatrick III-IV vs Fitzpatrick V-VI) generally mirrored those from the 2-group study. Study limitations include patient nonadherence, lack of a placebo arm, and lack of data regarding the impact of concurrent medications on outcomes. There was no correlation between irritation and Fitzpatrick skin type. ABBREVIATIONS USED: adverse event (AE), analysis of variance (ANOVA), benzoyl peroxide (BP), case report form (CRF), modified Global Acne Grading Score (mGAGS), tretinoin gel microsphere (TGM).
29 CFR 1910.1048 - Formaldehyde.
Code of Federal Regulations, 2011 CFR
2011-07-01
... evidence of irritation or sensitization of the skin and respiratory system, shortness of breath, or... make a decision within six months of the date the employee was removed as to whether the employee can... sensitization of the skin and respiratory system, eye and throat irritation, and acute toxicity. (2...
29 CFR 1910.1048 - Formaldehyde.
Code of Federal Regulations, 2010 CFR
2010-07-01
... evidence of irritation or sensitization of the skin and respiratory system, shortness of breath, or... make a decision within six months of the date the employee was removed as to whether the employee can... sensitization of the skin and respiratory system, eye and throat irritation, and acute toxicity. (2...
Evaluation of the skin irritation using a DNA microarray on a reconstructed human epidermal model.
Niwa, Makoto; Nagai, Kanji; Oike, Hideaki; Kobori, Masuko
2009-02-01
To avoid the need to use animals to test the skin irritancy potential of chemicals and cosmetics, it is important to establish an in vitro method based on the reconstructed human epidermal model. To evaluate skin irritancy efficiently and sensitively, we determined the gene expression induced by a topically-applied mild irritant sodium dodecyl sulfate (SDS) in a reconstructed human epidermal model LabCyte EPI-MODEL (LabCyte) using a DNA microarray carrying genes that were related to inflammation, immunity, stress and housekeeping. The expression and secretion of IL-1alpha in reconstructed human epidermal culture is known to be induced by irritation. We detected the induction of IL-1alpha expression and its secretion into the cell culture medium by treatment with 0.075% SDS for 18 h in LabCyte culture using DNA microarray, quantitative reverse-transcription polymerase chain reaction (RT-PCR) and ELISA. DNA microarray analysis indicated that the expression of 10 of the 205 genes carried on the DNA microarray was significantly induced in a LabCyte culture by 0.05% or 0.075% SDS irritation for 18 h. RT-PCR analysis confirmed that SDS treatment significantly induced the expressions of interleukin-1 receptor antagonist (IL-1RN), FOS-like antigen 1 (FOSL1), heat shock 70 kDa protein 1A (HSPA1) and myeloid differentiation primary response gene (88) (MYD88), as well as the known marker genes for irritation IL-1beta and IL-8 in a LabCyte culture. Our results showed that a DNA microarray is a useful tool for efficiently evaluating mild skin irritation using a reconstructed human epidermal model.
Fujimura, T; Shimotoyodome, Y; Nishijima, T; Sugata, K; Taguchi, H; Moriwaki, S
2017-02-01
Irritancy levels of surfactants on human skin have not been clarified completely. The relationships between skin damage and changes of skin properties caused by various surfactants were investigated using non-invasive measurements. Aqueous solutions of seven kinds of anionic, non-ionic, and amphoteric surfactants were exposed to the inside of forearm skin of 20 human subjects in two separate studies using the cup method. Hydration of the stratum corneum (SC), transepidermal water loss (TEWL), pH, skin surface roughness, and contents of the SC were measured before and after one exposure and after five and nine consecutive exposures to various surfactants. The discontinuation ratio of subjects for testing in each surfactant was determined by skin irritation symptoms and was defined as the degree of skin damage. Significant changes were observed only in hydration, TEWL, and natural moisturizing factors (NMF) content in the SC following surfactant exposure. A significant correlation was observed between the discontinuation ratio of each surfactant and the changes of hydration, TEWL, and NMF. Especially, the change of SC hydration showed an excellent correlation with the discontinuation ratio both for single (r = 0.942, P < 0.001) and for chronic exposures (r = 0.934, P < 0.001). Our results indicate that the change of hydration of the SC is equivalent to the skin damage caused by surfactants, and therefore is the most suitable indicator to evaluate the irritation of surfactants on the skin. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
40 CFR 157.22 - When required.
Code of Federal Regulations, 2011 CFR
2011-07-01
... irritation persisting for 21 days or more; (5) The pesticide is corrosive to the skin (causes tissue destruction into the dermis and/or scarring) or causes severe skin irritation (severe erythema or edema) at 72 hours; or (6) The pesticide or device has such characteristics that, based upon human toxicological data...
Darlenski, Razvigor; Kazandjieva, Jana; Tsankov, Nikolai; Fluhr, Joachim W
2013-11-01
The aim of the study was to disclose interactions between epidermal barrier, skin irritation and sensitization in healthy and diseased skin. Transepidermal water loss (TEWL) and stratum corneum hydration (SCH) were assessed in adult patients with atopic dermatitis (AD), rosacea and healthy controls. A 4-h patch test with seven concentrations of sodium lauryl sulphate was performed to determine the irritant threshold (IT). Contact sensitization pattern was revealed by patch testing with European baseline series. Subjects with a lower IT had higher TEWL values and lower SCH. Subjects with positive allergic reactions had significantly lower IT. In AD, epidermal barrier deterioration was detected on both volar forearm and nasolabial fold, while in rosacea, impeded skin physiology parameters were observed on the facial skin only, suggesting that barrier impediment is restricted to the face in rosacea, in contrast with AD where the abnormal skin physiology is generalized. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo
2014-01-01
The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis) for the treatment of dry eye syndrome in rabbits. Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis-treated group. The AUC₀₋₂₄ h for rabbit's tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis. These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes.
Viral skin diseases of the rabbit.
Meredith, Anna L
2013-09-01
This article describes the viral skin diseases affecting the domestic rabbit, the most important being myxomatosis. Transmission and pathogenesis, clinical signs, diagnosis, treatment, and control are described and the article will be of interest to veterinary practitioners who treat rabbits. Shope fibroma virus, Shope papilloma virus, and rabbitpox are also discussed. Copyright © 2013 Elsevier Inc. All rights reserved.
Biro, Kathrin; Thaçi, Diamant; Ochsendorf, Falk R; Kaufmann, Roland; Boehncke, Wolf-Henning
2003-08-01
Dexpanthenol is popular in treating various dermatoses and in skin care, but few controlled clinical trials have been performed. We investigated the efficacy of dexpanthenol in skin protection against irritation in a randomized, prospective, double-blind, placebo-controlled study. 25 healthy volunteers (age 18-45 years) were treated for the inner aspect of both forearms with either Bepanthol Handbalsam containing 5% dexpanthenol or placebo x2 daily for 26 days. From day 15-22, sodium lauryl sulfate (SLS) 2% was applied to these areas x2 daily. Documentation comprised sebumetry, corneometry, pH value and clinical appearance (photographs). 21 volunteers completed the study, 3 were excluded because of non-compliance and 1 experienced a non-study-related, severe, adverse event. Only corneometry yielded a statistically significant difference, with decreased values following SLS challenge at the placebo sites (P < 0.05). Intraindividual comparisons showed superior results at the dexpanthenol-treated sites in 11 cases and in only 1 case at the placebo site. 6 volunteers experienced an irritant contact dermatitis, with more severe symptoms at the placebo site in 5 cases. In conclusion, dexpanthenol exhibits protective effects against skin irritation. The initiation of a study to evaluate the efficacy of dexpanthenol in preventing irritant occupational contact dermatitis under real workplace conditions is validated.
Löffler, H; Happle, R
2003-01-01
The cutaneous reaction to detergents follows distinct kinetic rules: the duration of application and the irritant concentration are of major importance. The aim of this study was to evaluate the differences in kinetics of skin reaction between the standard irritant sodium lauryl sulfate (SLS), and 2 modern detergents: sodium laureth sulfate (SLES) and alkyl polyglucoside (APG). We performed patch testing with SLS and SLES (or APG) at different concentrations (0.125, 0.25, 0.5, 1.0 and 2.0%) and with different exposure times (6, 12 and 24 h). Evaluation was conducted by measurement of transepidermal water loss (TEWL) and laser Doppler flowmetry (LD) 24 h, 7 and 10 days after patch removal. We found a pronounced reaction to SLS, and a far milder one to SLES. Even at the highest concentration the skin reaction to APG was hard to detect. During the regeneration period (day 3-10) SLS showed even at day 10 an increased TEWL at all concentrations tested. The irritation due to SLES was convincingly detectable only up to day 7, whereas the APG-tested skin areas showed no significant reaction even at day 3. These results demonstrate the improvement in reduction of skin irritation achieved by development of novel detergents.
Dermal Sensitization Potential of Triethyleneglycol Dinitrate (TEGDN) in Guinea Pigs
1989-01-01
mutagenicity assay, acute oral toxicity tests in rats and mice, acute dermal toxicity in rabbits, dermal and ocular irritation studies in rabbits, and...conditions: 85E0102 had diffuse tracheitis, mild endocarditis , mild hepatitis, and diffuse pigment granules in the small intestine; 85E0103 had mild...severe ulceration progressing to necrosis. Sensitization is manifested as indirect inflammation mediated by components of the immune system in
Deters, A; Dauer, A; Schnetz, E; Fartasch, M; Hensel, A
2001-11-01
Although extracts from Hamamelis bark have long been used in therapy of skin diseases and in cosmetic formulas there are only few pharmacological investigations verifying the activity of distinct Hamamelis bark constituents. Therefore two major classes of constituents, namely polymeric proanthocyanidins and polysaccharides were isolated from Hamamelis bark and tested concerning their influence on proliferation and differentiation of cultured human keratinocytes. While the polysaccharide fraction, consisting mainly of arabans and arabinogalactans, did not effect human keratinozytes, the proanthocyanidins strongly increased the proliferation of the cells, while the differentiation was not influenced significantly. Within a preliminary cumulative in vivo study on SLS-irritated skin, proanthocyanidins (ProcyanoPlus) were proven to reduce transepidermal water loss and erythema formation. Furthermore, a clinical scoring indicated that procyanidins can influence irritative processes significantly.
Cotovio, José; Grandidier, Marie-Hélène; Lelièvre, Damien; Bremond, Christelle; Amsellem, Carolle; Maloug, Saber; Ovigne, Jean-Marc; Loisel-Joubert, Sophie; Lee, Aline Van Der; Minondo, Anne-Marie; Capallere, Christophe; Bertino, Béatrice; Alépée, Nathalie; Tinois-Tessonneaud, Estelle; de Fraissinette, Anne De Brugerolle; Meunier, Jean-Roch; Leclaire, Jacques
2010-03-01
The 7th amendment of the EU Cosmetics Directive led to the ban of eye irritation testing for cosmetic ingredients in animals, effective from March 11th 2009. Over the last 20years, many efforts have been made to find reliable and relevant alternative methods. The SkinEthic HCE model was used to evaluate the in vitro eye irritancy potential of substances from a cosmetic industry portfolio. An optimized protocol based on a specific 1-h treatment and a 16-h post-treatment incubation period was first assessed on a set of 102 substances. The prediction model (PM) based on a 50% viability cut-off, allowed to draw up two classes (Irritants and Non-Irritants), with good associated sensitivity (86.2%) and specificity (83.5%). To check the robustness of the method, the evaluated set was expanded up to 435 substances. Final performances maintained a high level and were characterized by an overall accuracy value > 82% when using EU or GHS classification rules. Results showed that the SkinEthic HCE test method is a promising in vitro tool for the prediction of eye irritancy. Optimization datasets were shared with the COLIPA Eye Irritation Project Team and ECVAM experts, and reviewed as part of an ongoing progression to enter an ECVAM prospective validation study for eye irritation. Copyright (c) 2009 Elsevier Ltd. All rights reserved.
[Studies on formulations of Panax notoginsenosides for intranasal administration].
Xu, Qing-fang; Fang, Xiao-ling; Chen, Dao-feng; Li, Jun-chan
2003-11-01
To develop high bioavailability preparations without irritation for Panax notoginsenosides. The effects of some additives such as microcrystalline cellulose, beta-cyclodextrin and hydroxypropyl cellulose on drug in the preparations were examined. Saponins of Panax notoginseng (PNS) was absorbed in rabbits more when administered intranasally than through other routines, and the formulations including MCC both gave high bioavailability and low irritation. Bioavailability of Panax notoginsenosides can be increased through changing routine of administration and formulations.
Luechtefeld, Thomas; Maertens, Alexandra; Russo, Daniel P.; Rovida, Costanza; Zhu, Hao; Hartung, Thomas
2017-01-01
Summary Public data from ECHA online dossiers on 9,801 substances encompassing 326,749 experimental key studies and additional information on classification and labeling were made computable. Eye irritation hazard, for which the rabbit Draize eye test still represents the reference method, was analyzed. Dossiers contained 9,782 Draize eye studies on 3,420 unique substances, indicating frequent retesting of substances. This allowed assessment of the test’s reproducibility based on all substances tested more than once. There was a 10% chance of a non-irritant evaluation after a prior severe-irritant result according to UN GHS classification criteria. The most reproducible outcomes were the results negative (94% reproducible) and severe eye irritant (73% reproducible). To evaluate whether other GHS categorizations predict eye irritation, we built a dataset of 5,629 substances (1,931 “irritant” and 3,698 “non-irritant”). The two best decision trees with up to three other GHS classifications resulted in balanced accuracies of 68% and 73%, i.e., in the rank order of the Draize rabbit eye test itself, but both use inhalation toxicity data (“May cause respiratory irritation”), which is not typically available. Next, a dataset of 929 substances with at least one Draize study was mapped to PubChem to compute chemical similarity using 2D conformational fingerprints and Tanimoto similarity. Using a minimum similarity of 0.7 and simple classification by the closest chemical neighbor resulted in balanced accuracy from 73% over 737 substances to 100% at a threshold of 0.975 over 41 substances. This represents a strong support of read-across and (Q)SAR approaches in this area. PMID:26863293
2007-01-01
Capsicum-derived ingredients function as skin-conditioning agents--miscellaneous, external analgesics, flavoring agents, or fragrance components in cosmetics. These ingredients are used in 19 cosmetic products at concentrations as high as 5%. Cosmetic-grade material may be extracted using hexane, ethanol, or vegetable oil and contain the full range of phytocompounds that are found in the Capsicum annuum or Capsicum frutescens plant (aka red chiles), including Capsaicin. Aflatoxin and N-nitroso compounds (N-nitrosodimethylamine and N-nitrosopyrrolidine) have been detected as contaminants. The ultraviolet (UV) absorption spectrum for Capsicum Annuum Fruit Extract indicates a small peak at approximately 275 nm, and a gradual increase in absorbance, beginning at approximately 400 nm. Capsicum and paprika are generally recognized as safe by the U.S. Food and Drug Administration for use in food. Hexane, chloroform, and ethyl acetate extracts of Capsicum Frutescens Fruit at 200 mg/kg resulted in death of all mice. In a short-term inhalation toxicity study using rats, no difference was found between vehicle control and a 7% Capsicum Oleoresin solution. In a 4-week feeding study, red chilli (Capsicum annuum) in the diet at concentrations up to 10% was relatively nontoxic in groups of male mice. In an 8-week feeding study using rats, intestinal exfoliation, cytoplasmic fatty vacuolation and centrilobular necrosis of hepatocytes, and aggregation of lymphocytes in the portal areas were seen at 10% Capsicum Frutescens Fruit, but not 2%. Rats fed 0.5 g/kg day-1 crude Capsicum Fruit Extract for 60 days exhibited no significant gross pathology at necropsy, but slight hyperemia of the liver and reddening of the gastric mucosa were observed. Weanling rats fed basal diets supplemented with whole red pepper at concentrations up to 5.0% for up to 8 weeks had no pathology of the large intestines, livers, and kidneys, but destruction of the taste buds and keratinization and erosion of the gastrointestinal (GI) tract were noted in groups fed 0.5% to 5.0% red pepper. The results of 9-and 12-month extension of this study showed normal large intestines and kidneys. In rabbits fed Capsicum Annuum Powder at 5 mg/kg day-1 in the diet daily for 12 months damage to the liver and spleen was noted. A rabbit skin irritation test of Capsicum Annuum Fruit Extract at concentrations ranging from 0.1% to 1.0% produced no irritation, but Capsicum Frutescens Fruit Extract induced concentration-dependent (at 25 to 500 microg/ml) cytotoxicity in a human buccal mucosa fibroblast cell line. An ethanol extract of red chili was mutagenic in Salmonella typhimurium TA98, but not in TA100, or in Escherichia coli. Other genotoxicity assays gave a similar pattern of mixed results. Adenocarcinoma of the abdomen was observed in 7/20 mice fed 100 mg red chilies per day for 12 months; no tumors were seen in control animals. Neoplastic changes in the liver and intestinal tumors were observed in rats fed red chili powder at 80 mg/kg day-1 for 30 days, intestinal and colon tumors were seen in rats fed red chili powder and 1,2-dimethyl hydrazine, but no tumors were observed in controls. In another study in rats, however, red chile pepper in the diet at the same dose decreased the number of tumors seen with 1,2-dimethylhydrazine. Other feeding studies evaluated the effect of red chili peppers on the incidence of stomach tumors produced by N-methyl-N'-nitro-N-nitrosoguanidine, finding that red pepper had a promoting effect. Capsicum Frutescens Fruit Extract promoted the carcinogenic effect of methyl(acetoxymethyl)nitrosamine (carcinogen) or benzene hexachloride (hepatocarcinogen) in inbred male and female Balb/c mice dosed orally (tongue application). Clinical findings include symptoms of cough, sneezing, and runny nose in chili factory workers. Human respiratory responses to Capsicum Oleoresin spray include burning of the throat, wheezing, dry cough, shortness of breath, gagging, gasping, inability to breathe or speak, and, rarely, cyanosis, apnea, and respiratory arrest. A trade name mixture containing 1% to 5% Capsicum Frutescens Fruit Extract induced very slight erythema in 1 of 10 volunteers patch tested for 48 h. Capsicum Frutescens Fruit Extract at 0.025% in a repeated-insult patch test using 103 subjects resulted in no clinically meaningful irritation or allergic contact dermatitis. One epidemiological study indicated that chili pepper consumption may be a strong risk factor for gastric cancer in populations with high intakes of chili pepper; however, other studies did not find this association. Capsaicin functions as an external analgesic, a fragrance ingredient, and as a skin-conditioning agent--miscellaneous in cosmetic products, but is not in current use. Capsaicin is not generally recognized as safe and effective by the U.S. Food and Drug Administration for fever blister and cold sore treatment, but is considered to be safe and effective as an external analgesic counterirritant. Ingested Capsaicin is rapidly absorbed from the stomach and small intestine in animal studies. Subcutaneous injection of Capsaicin in rats resulted in a rise in the blood concentration, reaching a maximum at 5 h; the highest tissue concentrations were in the kidney and lowest in the liver. In vitro percutaneous absorption of Capsaicin has been demonstrated in human, rat, mouse, rabbit, and pig skin. Enhancement of the skin permeation of naproxen (nonsteroidal anti-inflammatory agent) in the presence of Capsaicin has also been demonstrated. Pharmacological and physiological studies demonstrated that Capsaicin, which contains a vanillyl moiety, produces its sensory effects by activating a Ca2 +-permeable ion channel on sensory neurons. Capsaicin is a known activator of vanilloid receptor 1. Capsaicin-induced stimulation of prostaglandin biosynthesis has been shown using bull seminal vesicles and rheumatoid arthritis synoviocytes. Capsaicin inhibits protein synthesis in Vero kidney cells and human neuroblastoma SHSY-5Y cells in vitro, and inhibits growth of E. coli, Pseudomonas solanacearum, and Bacillus subtilis bacterial cultures, but not Saccharomyces cerevisiae. Oral LD50 values as low as 161.2 mg/kg (rats) and 118.8 mg/kg (mice) have been reported for Capsaicin in acute oral toxicity studies, with hemorrhage of the gastric fundus observed in some of the animals that died. Intravenous, intraperitoneal, and subcutaneous LD50 values were lower. In subchronic oral toxicity studies using mice, Capsaicin produced statistically significant differences in the growth rate and liver/body weight increases. Capsaicin is an ocular irritant in mice, rats, and rabbits. Dose-related edema was observed in animals receiving Capsaicin injections into the hindpaw (rats) or application to the ear (mice). In guinea pigs, dinitrochlorobenzene contact dermatitis was enhanced in the presence of Capsaicin, injected subcutaneously, whereas dermal application inhibited sensitization in mice. Immune system effects have been observed in neonatal rats injected subcutaneously with Capsaicin. Capsaicin produced mixed results in S. typhimurium micronucleus and sister-chromatid exchange genotoxicity assays. Positive results for Capsaicin were reported in DNA damage assays. Carcinogenic, cocarcinogenic, anticarcinogenic, antitumorigenic, tumor promotion, and anti-tumor promotion effects of Capsaicin have been reported in animal studies. Except for a significant reduction in crown-rump length in day 18 rats injected subcutaneously with Capsaicin (50 mg/kg) on gestation days 14, 16, 18, or 20, no reproductive or developmental toxicity was noted. In pregnant mice dosed subcutaneously with Capsaicin, depletion of substance P in the spinal cord and peripheral nerves of pregnant females and fetuses was noted. In clinical tests, nerve degeneration of intracutaneous nerve fibers and a decrease in pain sensation induced by heat and mechanical stimuli were evident in subjects injected intradermally with Capsaicin. An increase in mean inspiratory flow was reported for eight normal subjects who inhaled nebulized 10(-7) M Capsaicin. The results of provocative and predictive tests involving human subjects indicated that Capsaicin is a skin irritant. Overall, studies suggested that these ingredients can be irritating at low concentrations. Although the genotoxicity, carcinogenicity, and tumor promotion potential of Capsaicin have been demonstrated, so have opposite effects. Skin irritation and other tumor-promoting effects of Capsaicin appear to be mediated through interaction with the same vanilloid receptor. Given this mechanism of action and the observation that many tumor promoters are irritating to the skin, the Panel considered it likely that a potent tumor promoter may also be a moderate to severe skin irritant. Thus, a limitation on Capsaicin content that would significantly reduce its skin irritation potential is expected to, in effect, lessen any concerns relating to tumor promotion potential. Because Capsaicin enhanced the penetration of an anti-inflammatory agent through human skin, the Panel recommends that care should be exercised in using ingredients that contain Capsaicin in cosmetic products. The Panel advised industry that the total polychlorinated biphenyl (PCB)/pesticide contamination should be limited to not more than 40 ppm, with not more than 10 ppm for any specific residue, and agreed on the following limitations for other impurities: arsenic (3 mg/kg max), heavy metals (0.002% max), and lead (5 mg/kg max). Industry was also advised that aflatoxin should not be present in these ingredients (the Panel adopted < or =15 ppb as corresponding to "negative" aflatoxin content), and that ingredients derived from Capsicum annuum and Capsicum Frutescens Plant species should not be used in products where N-nitroso compounds may be formed. (ABSTRACT TRUNCATED)
Irritant contact dermatitis in warehouse employees.
Ashworth, J; Rycroft, R J; Waddy, R S; Irvine, D
1993-02-01
A detailed survey of skin complaints amongst 114 airline employees working in a new warehouse revealed 26 cases of skin problems which originated during the 2 1/2 year operation. A clinical survey of broadly the same population confirmed 14 cases from 98 employees as chronic irritant contact dermatitis of the hands. The work involved the reception, unpackaging, inspection, repackaging and dispatch of aircraft parts. The source of the skin irritation was not to be found in the work itself. Rather, the presence among the employees of two severe cases of non-occupational eczema, combined with the idea that incoming aircraft parts from foreign countries might be 'dirty' in some way, had caused a heightened perception of a risk of skin disease, and the frequency of hand washing had increased as a result. Over-frequent hand washing in a few employees had resulted in precisely what the warehouse staff had been trying to avoid.
Pappinen, Sari; Tikkinen, Sanna; Pasonen-Seppänen, Sanna; Murtomäki, Lasse; Suhonen, Marjukka; Urtti, Arto
2007-03-01
The objective of this study was to evaluate the response of the rat epidermal keratinocyte organotypic culture (ROC) to permeation enhancers, and to compare these responses to those in human cadaver skin. Different concentrations of two mixtures for enhancing permeation were investigated, sodium dodecyl sulfate:phenyl piperazine and methyl pyrrolidone:dodecyl pyridinium chloride, using skin impedance spectroscopy and two experimental compounds, the lipophilic corticosterone and the hydrophilic sucrose. The chemical irritation effects of the formulations were evaluated based on leakage of lactate dehydrogenase enzyme (LDH) and cellular morphological perturbation. This study provides evidence for direct correlations of permeation/permeation, impedance/impedance and permation/impedance between the culture model and human skin. The only exception was the enhancer induced permeation of sucrose which was 1-40-fold higher in ROC compared to human skin, reflecting the more disordered lipid organization in stratum corneum and consequently the greater number of polar pathways. LDH leakage and cellular morphology indicated that it was possible to differentiate between safe permeation enhancers from irritating agents. This is not only the first study to have compared the enhancer effects on a cultured skin model with human skin, but also it has demonstrated enhancer induced irritation using an artificial skin model.
NASA Astrophysics Data System (ADS)
Jan Tic, Wilhelm
2017-10-01
Solvents are primarily used for making protective coatings. Considering their chemical nature, there are a great variety of coatings, including those based on liquid hydrocarbons and organic chloroderivatives. These products are a serious load to the environment because of their physicochemical properties, therefore, they have for some time been replaced with more-environmentally friendly, new generation products. One of them is the hydroxyester HE-1: made from isobutyric aldehyde condensation products, it is an alternative to those coalescents for paints and varnishes which are intended to be replaced or their use restricted. The results of selected toxicological tests relating to the human health risk effect of the hydroxyester HE-1 - environmentally-friendly additive to paints and varnishes are presented. The test results indicate that HE-1 causes skin irritation in rabbit only when used at its maximum concentrations. No lesions in the cornea or iris were observed in any of the test rabbits after the application of the hydroxyester HE-1. In the mutagenic effect test of HE-1 on the bacteria Salmonella typhimurium, the result was negative. Based on the test results, it was found that the hydroxyester HE-1 may only have a human health risk effect when used at its maximum concentrations.
Proksch, E; Nissen, H P
2002-12-01
Dexpanthenol-containing creams have been widely used for treatment of lesions (superficial wounds) of the skin and mucous membranes. Dexpanthenol is converted in tissues to pantothenic acid, a component of coenzyme A. Coenzyme A catalyses early steps in the synthesis of fatty acids and sphingolipids which are of crucial importance for stratum corneum lipid bilayers and cell membrane integrity. In the present study, the effects were examined of a dexpanthenol-containing cream on skin barrier repair, stratum corneum hydration, skin roughness, and inflammation after sodium lauryl sulphate (SLS)-induced irritation. Irritation was induced by application of SLS in patch test chambers. The dexpanthenol-contaming cream or the vehicle were applied twice daily and barrier repair, hydration, roughness, and inflammation of the skin were determined by using biophysical methods. Significantly accelerated skin barrier repair was found in treatments with the dexpanthenol-containing cream (verum) compared with vehicle-treated (placebo) or untreated skin. Both verum and placebo showed an increase in stratum corneum hydration, but significantly more so with the dexpanthenol-containing cream. Both creams reduced skin roughness, but again the verum was superior. The dexpanthenol-containing cream significantly reduced skin redness as a sign of inflammation in contrast to the vehicle, which produced no effect. Treatment with a dexpanthenol-containing cream showed significantly enhanced skin barrier repair and stratum corneum hydration, while reducing skin roughness and inflammation.
25 CFR 309.13 - What are examples of other weaving and textiles that are Indian products?
Code of Federal Regulations, 2012 CFR
2012-04-01
..., including, but not limited to, cornhusk, raffia, tule, horsehair, cotton, wool, fiber, linen, rabbit skin..., star quilts, pictorial appliqué wall hangings, fiber woven bags, embroidered dance shawls, rabbit skin...
25 CFR 309.13 - What are examples of other weaving and textiles that are Indian products?
Code of Federal Regulations, 2013 CFR
2013-04-01
..., including, but not limited to, cornhusk, raffia, tule, horsehair, cotton, wool, fiber, linen, rabbit skin..., star quilts, pictorial appliqué wall hangings, fiber woven bags, embroidered dance shawls, rabbit skin...
25 CFR 309.13 - What are examples of other weaving and textiles that are Indian products?
Code of Federal Regulations, 2014 CFR
2014-04-01
..., including, but not limited to, cornhusk, raffia, tule, horsehair, cotton, wool, fiber, linen, rabbit skin..., star quilts, pictorial appliqué wall hangings, fiber woven bags, embroidered dance shawls, rabbit skin...
... lack of responsiveness) Dizziness Impaired memory Insomnia Irritability Loss of coordination Sensation of being drunk Severe brain damage Sleepiness Stupor (decreased level of consciousness) Walking difficulties SKIN Burns Irritation
Groeber, F; Schober, L; Schmid, F F; Traube, A; Kolbus-Hernandez, S; Daton, K; Hoffmann, S; Petersohn, D; Schäfer-Korting, M; Walles, H; Mewes, K R
2016-10-01
To replace the Draize skin irritation assay (OECD guideline 404) several test methods based on reconstructed human epidermis (RHE) have been developed and were adopted in the OECD test guideline 439. However, all validated test methods in the guideline are linked to RHE provided by only three companies. Thus, the availability of these test models is dependent on the commercial interest of the producer. To overcome this limitation and thus to increase the accessibility of in vitro skin irritation testing, an open source reconstructed epidermis (OS-REp) was introduced. To demonstrate the capacity of the OS-REp in regulatory risk assessment, a catch-up validation study was performed. The participating laboratories used in-house generated OS-REp to assess the set of 20 reference substances according to the performance standards amending the OECD test guideline 439. Testing was performed under blinded conditions. The within-laboratory reproducibility of 87% and the inter-laboratory reproducibility of 85% prove a high reliability of irritancy testing using the OS-REp protocol. In addition, the prediction capacity was with an accuracy of 80% comparable to previous published RHE based test protocols. Taken together the results indicate that the OS-REp test method can be used as a standalone alternative skin irritation test replacing the OECD test guideline 404. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Proteomic Analysis of the Human Skin Proteome after In Vivo Treatment with Sodium Dodecyl Sulphate
Parkinson, Erika; Skipp, Paul; Aleksic, Maja; Garrow, Andrew; Dadd, Tony; Hughes, Michael; Clough, Geraldine; O′Connor, C. David
2014-01-01
Background Skin has a variety of functions that are incompletely understood at the molecular level. As the most accessible tissue in the body it often reveals the first signs of inflammation or infection and also represents a potentially valuable source of biomarkers for several diseases. In this study we surveyed the skin proteome qualitatively using gel electrophoresis, liquid chromatography tandem mass spectrometry (GeLC-MS/MS) and quantitatively using an isobaric tagging strategy (iTRAQ) to characterise the response of human skin following exposure to sodium dodecyl sulphate (SDS). Results A total of 653 skin proteins were assigned, 159 of which were identified using GeLC-MS/MS and 616 using iTRAQ, representing the most comprehensive proteomic study in human skin tissue. Statistical analysis of the available iTRAQ data did not reveal any significant differences in the measured skin proteome after 4 hours exposure to the model irritant SDS. Conclusions This study represents the first step in defining the critical response to an irritant at the level of the proteome and provides a valuable resource for further studies at the later stages of irritant exposure. PMID:24849295
Czajkowska-Kośnik, Anna; Wolska, Eliza; Chorążewicz, Juliusz; Sznitowska, Małgorzata
2015-01-01
The in vivo model on rabbit eyes and the in vitro cytotoxicity on fibroblasts were used to compare irritation effect of aqueous and oily (Miglyol 812) solutions of surfactants. Tween 20, Tween 80 and Cremophor EL were tested in different concentrations (0.1, 1 or 5%) and the in vitro test demonstrated that surfactants in oil are less cytotoxic than in aqueous solutions. In the in vivo study, the aqueous solutions of surfactants were characterized as non-irritant while small changes in conjunctiva were observed after application the oily solutions of surfactants and the preparations were classified as slightly irritant, however this effect was similar when Miglyol was applied alone. In conclusion, it is reported that the MTT assay does not correlate well with the Draize scores.
Ikarashi, Y; Tsuchiya, T; Nakamura, A
1997-01-01
Cytotoxicity potential of chemicals was evaluated by determining the concentrations inducing 50% reduction of neutral red (NR) uptake into Chinese hamster fibroblast V79 cells compared with control culture (IC50). The results of cytotoxicity test for surfactants with the data produced by the in vivo Draize eye and skin irritation test were compared. There was a good correlation between cytotoxicity and eye irritation score obtained from the Draize test. In contrast, no correlation was observed between Draize skin irritation score and cytotoxic potential of chemicals. Therefore, the NR cytotoxicity test was regarded as a possible in vitro model for predicting eye irritation. Based on the IC50 values in the NR cytotoxicity test, the eye irritation classification (weak, moderate and strong) for each chemical used in household products has been established. We evaluated the cytotoxicity of 25 chemicals used for antimicrobial, rubber accelerator, rubber antioxidant, ultraviolet absorber etc. in household products, and estimated the eye irritating potency of these test chemicals according to the criterion.
Immunophenotyping does not improve predictivity of the local lymph node assay in mice.
Strauss, Volker; Kolle, Susanne N; Honarvar, Naveed; Dammann, Martina; Groeters, Sibylle; Faulhammer, Frank; Landsiedel, Robert; van Ravenzwaay, Bennard
2015-04-01
The local lymph node assay (LLNA) is a regulatory accepted test for the identification of skin sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. However, there is evidence that LLNA is overestimating the sensitization potential of certain substance classes in particular those exerting skin irritation. Some reports describe the additional use of flow cytometry-based immunophenotyping to better discriminate irritants from sensitizing irritants in LLNA. In the present study, the 22 performance standards plus 8 surfactants were assessed using the radioactive LLNA method. In addition, lymph node cells were immunophenotyped to evaluate the specificity of the lymph node response using cell surface markers such as B220 or CD19, CD3, CD4, CD8, I-A(κ) and CD69 with the aim to allow a better discrimination above all between irritants and sensitizers, but also non-irritating sensitizers and non-sensitizers. However, the markers assessed in this study do not sufficiently differentiate between irritants and irritant sensitizers and therefore did not improve the predictive capacity of the LLNA. Copyright © 2014 John Wiley & Sons, Ltd.
Ziel, Kristin; Yelverton, Christopher B; Balkrishnan, Rajesh; Feldman, Steven R
2005-01-01
Metronidazole 0.75% gel and azelaic acid 15% gel are commonly used to treat rosacea. Irritation is a common side effect. To assess the cumulative irritation potential of metronidazole 0.75% gel and azelaic acid 15% gel. Metronidazole 0.75% gel, azelaic acid 15% gel, and a white petrolatum negative control were applied under occlusive conditions to the upper back of a total of 33 healthy subjects. There were twelve 24-hour applications (4 times a week) and three 72-hour applications on weekends during a 3-week period. Skin reactions (erythema score +/- other local reaction) were assessed within 15 to 30 minutes of removal of the products. The mean cumulative irritancy index of metronidazole 0.75% gel was significantly lower than that of azelaic acid 15% gel and not significantly higher than the negative control product. There was increasing cumulative irritancy with azelaic acid; no cumulative irritancy was seen for either metronidazole or white petrolatum. Metronidazole 0.75% gel is less irritating in sustained use than azelaic acid 15% gel.
Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo
2014-01-01
Background The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis®) for the treatment of dry eye syndrome in rabbits. Methods Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis®-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. Results After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis®-treated group. The AUC0–24 h for rabbit’s tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis®. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis®. Conclusion These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes. PMID:25143728
... skin problems such as redness, peeling, irritation, and yeast infections likely. Bedsores ( pressure sores ) may also develop ... drying the skin. Incontinence problems can cause a yeast infection on the skin. This is an itchy, ...
Morales, Mariana; Pérez, David; Correa, Luis; Restrepo, Luz
2016-10-01
Reconstructed human epidermis (RhE) models have been used for in vitro testing of the potential harmful effects of exposure to chemical compounds on health. In the past, skin irritation and corrosion were evaluated in animal models; however, in recent years, due to the bioethics implications of the method and, to minimize the use of experimental animals, alternative procedures have been proposed. The Organisation for Economic Co-operation and Development (OECD) in its test guidelines (TG) 431 and 439 indicates the requirements for validating new methods for the evaluation of skin corrosion and irritation, respectively. Here, we present an in-house human dermal-epidermal model, useful for the performance of these tests. Using the methods described in this work, it was possible to obtain human fibrin-based dermal-epidermal organotypic skin cultures (ORGs) displaying similar histological characteristics to native skin and expressing specific differentiation epithelial proteins. The end points to classify a substance as irritant or corrosive were cell viability evaluated by MTT assay, and cytokine release measured by BD CBA for human inflammatory cytokines. According to the MTT test, the ORGs correctly classified irritating and corrosive substances. Moreover, the cytokine release assay was difficult to interpret in the context of testing chemical hazard classification. Further experiments are needed to validate this new model for the evaluation of surfactants because the fibrin matrix was affected in the presence of these substances. Copyright © 2016 Elsevier B.V. All rights reserved.
1985-01-10
irritation photochemical chemical and 10 percent reaction under test con- irritation in humans. (wlv) Oil of Bergamot ditions. 2 * - Study No. 75-51-0367-85...control (oil of Bergamot ), than unirradiated skin areas. a and diluent were applied to additional skin areas to serve as unirradiated control sites
Induction of a Hardening Phenomenon and Quantitative Changes of Ceramides in Stratum Corneum
Park, Sook Young; Kim, Jin Hye; Cho, Soo Ick; Kim, Kyeong Il; Cho, Hee Jin; Park, Chun Wook; Lee, Cheol Heon
2014-01-01
Background Hardening phenomenon of human skin after repeated exposure to the irritants is well-known, but the precise mechanism remains elusive. Objective To modify the previous experimental model of hardening phenomenon by repeated applications of two different concentrations of sodium lauryl sulfate (SLS) solutions to Korean healthy volunteers and to investigate the quantitative changes of ceramides in stratum corneum before and after chronic repeated irritation. Methods Eight hundred microliters of distilled water containing 0.1% and 2% SLS was applied for 10 minutes on the forearm of 41 healthy volunteers for 3 weeks. After an intervening 3-week rest, 24-hour patch tests with 1% SLS were conducted on previously irritated sites. Transepidermal water loss (TEWL), erythema index and quantity of ceramide were measured in the stratum corneum before and after irritation. Results TEWL values on the sites preirritated with 2% SLS were lower than those with 0.1% SLS. Hardening phenomenon occurred in 24 volunteers at day 44. The changes in ceramide levels were not significantly higher in the hardened skin than in the non-hardened skin. Conclusion Repetitive stimulation with a higher concentration of SLS can more easily trigger skin hardening. PMID:24648684
Role of macromolecules in the safety of use of body wash cosmetics.
Bujak, Tomasz; Wasilewski, Tomasz; Nizioł-Łukaszewska, Zofia
2015-11-01
One of the most challenging problems related to the use of surfactants in body wash cosmetics is their potential to cause skin irritations. Surfactants can bind with proteins, remove lipids from the epidermal surface, contribute to the disorganization of liquid crystal structures in the intercellular lipids, and interact with living skin cells. These processes can lead to skin irritations and allergic reactions, and impair the epidermal barrier function. The present study is an attempt to assess the effect of polymers and hydrolysed proteins present in the formulations of model body wash cosmetics on product properties. Special attention was given to the safety of use of this product type. The study examined three macromolecules: polyvinylpyrrolidone (PVP), hydrolysed wheat protein (HWP) and polyvinylpyrrolidone/hydrolysed wheat protein crosspolymer (PVP/HWP). The addition of the substances under study was found to improve the foaming properties of body wash cosmetics, increase their stability during storage, and contribute significantly to an improvement in the safety of product use by reducing the irritant potential. The strongest ability to reduce the skin irritation potential was determined for the formula enriched with the PVP/HWP crosspolymer. Copyright © 2015 Elsevier B.V. All rights reserved.
Assessment of Irritation and Sensitization Potential of Eight Baby Skin Care Products.
Galzote, Carlos; Thomas, Mini; Sachdev, Mukta
2016-10-01
Ethnic differences in skin sensitivity suggest that greater emphasis be focused on understanding a product's effect in diverse populations. The irritation and/or sensitization potential of 8 baby skin care products in Indian adults were evaluated using cumulative irritation tests (CIT) and human repeat insult patch testing (HRIPT) protocols. Healthy males or females aged 18 to 65 years of Indian ethnicity were treated with each of 6 products (cream, hair oil, lotion, body wash, shampoo, and baby soap) using CIT (n = 25) and HRIPT (n = 200). Baby powder and baby oil were evaluated by CIT (n = 25) and HRIPT (n = 107) in separate studies. CITs were conducted over 14 days; HRIPTs were conducted over 10 weeks. In both CIT and HRIPT, most products were considered mild, with no irritation. Baby soap and powder elicited reactions in the HRIPT induction phase, with positive challenge phase reactions (3 subjects), but were affirmed to be nonallergenic in the rechallenge phase. In these studies, 8 baby skin care products were evaluated by both CIT and HRIPT in Indian adults. The results of the studies indicated that all of the tested products were nonallergenic and nonirritating.
J Drugs Dermatol. 2016;15(10):1244-1248.
Occupational allergic and irritant contact dermatitis in workers exposed to polyurethane foam.
Kieć-Świerczyńska, Marta; Swierczyńska-Machura, Dominika; Chomiczewska-Skóra, Dorota; Nowakowska-Świrta, Ewa; Kręcisz, Beata
2014-04-01
To evaluate sensitization to chemicals present in work environment after an outbreak of contact dermatitis in workers of vehicle equipment factory, exposed to polyurethane foam, based on 4,4'-diphenylmethane diisocyanate (MDI). From among 300 employees, 21 individuals reporting work-related skin and/or respiratory tract symptoms underwent clinical examination, patch testing, skin prick tests, spirometry and MDI sIgE measurement in serum. Patch tests included isocyanates series, selected rubber additives, metals, fragrances, preservatives, and an antiadhesive agent. Clinical examination revealed current eczema in the area of hands and/or forearms in 10 workers. Positive patch test reactions were found in 10 individuals, the most frequent to diaminodiphenylmethane and 4-phenylenediamine (7 persons). Reactions to an antiadhesive agent were assessed as irritant (5 workers). Except for sensitization to common aeroallergens, no significant abnormalities were found in the remaining tests. Occupational allergic contact dermatitis was diagnosed in 7 workers, irritant contact dermatitis in 10 and coexisiting allergic and irritant contact dermatitis in 3 workers. In workers manufacturing products from polyurethane foam, attention should be paid to the risk of developing contact dermatitis. Skin problems in our study group were attributable probably to insufficient protection of the skin.
Schivo, Michael; Aksenov, Alexander A; Pasamontes, Alberto; Cumeras, Raquel; Weisker, Sandra; Oberbauer, Anita M; Davis, Cristina E
2017-01-01
Human skin presents a large, easily accessible matrix that is potentially useful for diagnostic applications based on whole body metabolite changes – some of which will be volatile and detected using minimally invasive tools. Unfortunately, identifying skin biomarkers that can be reliably linked to a particular condition is challenging due to a large variability of genetics, dietary intake, environmental exposures within human populations. This leads to a paucity of clinically validated volatile skin biomarker compounds. Animal models present a very convenient and attractive way to circumvent many of the variability issues. The rabbit (Leporidae) is a potentially logistically useful model to study the skin metabolome, but very limited knowledge of its skin metabolites exists. Here we present the first comprehensive assessment of the volatile fraction of rabbit skin metabolites using polydimethylsiloxane sorbent patch sampling in conjunction with gas chromatography / mass spectrometry (GC/MS). A collection of compounds that are secreted from rabbit skin was documented, and predominantly acyclic long-chain alkyls and alcohols were detected. We then utilized this animal model to study differences between intact skin and skin with early pressure ulcers, as the latter are a major problem in intensive care units. Four New Zealand female white rabbits underwent ulcer formation on one ear with the other ear as a control. Early-stage ulcers were created with neodymium magnets. Histologic analysis showed acute heterophilic dermatitis, edema, and micro-hemorrhage on the ulcerated ears with normal findings on the control ears. The metabolomic analysis revealed subtle but noticeable differences, with several compounds associated with the oxidative stress-related degradation of lipids found to be present in greater abundances in ulcerated ears. The metabolomic findings correlate with histologic evidence of early-stage ulcers. We postulate that the Leporidae model recapitulated the vascular changes associated with ulcer formation. This study illustrates the potential usefulness of the Leporidae model for skin metabolome studies as illustrated by this study of early-stage ulcer formation. PMID:28068292
Extended followup of a cohort of chromium production workers
Lees, Peter St. John; Wang, Jing; Grace O'Leary, Keri
2015-01-01
Background The current study evaluates the mortality of 2,354 workers first employed at a Baltimore chromate production plant between 1950 and 1974. Methods The National Death Index (NDI Plus) was used to determine vital status and cause of death. Cumulative chromium (VI) exposure and nasal and skin irritation were evaluated as risk factors for lung cancer mortality. Results There are 91,186 person‐years of observation and 217 lung cancer deaths. Cumulative chromium (VI) exposure, nasal irritation, nasal perforation, nasal ulceration, and other forms of irritation (e.g., skin irritation) were associated with lung cancer mortality. Conclusion Cumulative chromium (VI) exposure was a risk factor for lung cancer death. Cancer deaths, other than lung cancer, were not significantly elevated. Irritation may be a possible mechanism for chromium (VI)‐induced lung cancer. Am. J. Ind. Med. 58:905–913, 2015. © 2015 The Authors. American Journal of Industrial Medicine Published by Wiley Periodicals, Inc. PMID:26041683
The Yucatan miniature swine as an in vivo model for screening skin depigmentation.
Nair, X; Tramposch, K M
1991-12-01
The usefulness of the Yucatan miniature pig as a screen for skin dipigmenting activity by topical application was evaluated with standard compounds. This is a naturally occurring breed of swine with light brown to dark brown skin that is relatively hairless. The skin morphology, including the pattern of pigment distribution, in this breed of swine closely resembles the human skin. Test compounds examined in this study included the three standard compounds with known clinical depigmenting activity, hydroquinone (HQ), 4-hydroxyanisole (4HA) and tert-butyl catechol (TBC), each at a 5% concentration. Test materials in 25 microliters of propylene glycol/ethanol (50:50) were applied topically twice daily, 7 days a week for 90 days to test sites on each side of the dorsal mid-line. Test sites were graded weekly for variation in pigmentation and local irritation. After 90 days of test material application, skin biopsies of the test sites were taken for histological evaluation. Topical application of HQ, 4HA and TBC promoted marked skin depigmentation which was substantiated by reductions of pigment and melanocytes observed on microscopic examination. While both HQ and TBC produced marked local irritation, 4HA was only mildly irritating. These results suggest that the Yucatan pig, could be a potentially useful model for screening compounds with skin depigmenting activity.
Yeom, Mijung; Kim, Sung-Hun; Lee, Bombi; Han, Jeong-Jun; Chung, Guk Hoon; Choi, Hee-Don; Lee, Hyejung; Hahm, Dae-Hyun
2012-08-01
Irritant contact dermatitis (ICD) is an inflammatory skin disease triggered by exposure to a chemical that is toxic or irritating to the skin. A major characteristic of chronic ICD is an inflammatory dry-skin condition with associated itching. Although glucosylceramide (GlcCer) is known to improve the skin barrier function, its mechanism of action is unknown. Using a mouse model of oxazolone-induced chronic ICD, this study investigated the effects of oral administration of GlcCer on inflammatory dry skin. Chronic ICD was induced by repeated application of oxazolone in mice. GlcCer was orally administered once daily throughout the elicitation phase. The beneficial efficacy of GlcCer on cutaneous inflammation was evaluated by assessing ear thickness, lymph node weight, histological findings, and mRNA expression of pro-inflammatory cytokines such as IL-1β and IL-6. Additionally, parameters of the itch-associated response, including scratching behavior, water content of the skin, and aquaporin-3 levels in the lesional ear, were measured. Oral GlcCer administration significantly suppressed mRNA expression of the pro-inflammatory cytokines IL-1β and IL-6. GlcCer also suppressed ear swelling, lymph node weight gains, and infiltration of leukocytes and mast cells in ICD mice. In oxazolone-induced ICD mice, GlcCer significantly inhibited irritant-related scratching behavior and dehydration of the stratum corneum, and decreased aquaporin-3 expression. Our results indicate that GlcCer suppressed inflammation not only by inhibiting cytokine production but also by repairing the skin barrier function, suggesting a potential beneficial role for GlcCer in the improvement of chronic ICD. Copyright © 2012 Japanese Society for Investigative Dermatology. Published by Elsevier Ireland Ltd. All rights reserved.
The male beard hair and facial skin - challenges for shaving.
Maurer, M; Rietzler, M; Burghardt, R; Siebenhaar, F
2016-06-01
The challenge of shaving is to cut the beard hair as closely as possible to the skin without unwanted effects on the skin. To achieve this requires the understanding of beard hair and male facial skin biology as both, the beard hair and the male facial skin, contribute to the difficulties in obtaining an effective shave without shaving-induced skin irritation. Little information is available on the biology of beard hairs and beard hair follicles. We know that, in beard hairs, the density, thickness, stiffness, as well as the rates of elliptical shape and low emerging angle, are high and highly heterogeneous. All of this makes it challenging to cut it, and shaving techniques commonly employed to overcome these challenges include shaving with increased pressure and multiple stroke shaving, which increase the probability and extent of shaving-induced skin irritation. Several features of male facial skin pose problems to a perfect shave. The male facial skin is heterogeneous in morphology and roughness, and male skin has a tendency to heal slower and to develop hyperinflammatory pigmentation. In addition, many males exhibit sensitive skin, with the face most often affected. Finally, the hair follicle is a sensory organ, and the perifollicular skin is highly responsive to external signals including mechanical and thermal stimulation. Perifollicular skin is rich in vasculature, innervation and cells of the innate and adaptive immune system. This makes perifollicular skin a highly responsive and inflammatory system, especially in individuals with sensitive skin. Activation of this system, by shaving, can result in shaving-induced skin irritation. Techniques commonly employed to avoid shaving-induced skin irritation include shaving with less pressure, pre- and post-shave skin treatment and to stop shaving altogether. Recent advances in shaving technology have addressed some but not all of these issues. A better understanding of beard hairs, beard hair follicles and male facial skin is needed to develop novel and better approaches to overcome the challenge of shaving. This article covers what is known about the physical properties of beard hairs and skin and why those present a challenge for blade and electric shaving, respectively. © 2016 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolfe, R.E.; Kinead, E.R.; Feldmann, M.L.
1996-11-01
To reduce fuel fouling in current U.S Navy and Air Force aircraft systems and to provide additional heat sink and thermal stability for future systems, the Air Force is developing an improved JP-8 jet fuel (JP-8 + 100). Two companies (Betz and Mobil) have developed additive packages that are currently being tested in aircraft systems. To determine if the additive packages will produce health effects for flightline personnel, acute testing was performed on JP-8 and the two JP-8 + 100 jet fuels. A single oral dose at 5 mg jet fuel/kg body weight to five male and five female F-344more » rats, and a single dermal application of 2 g jet fuel/kg body weight applied to five male and five female NZW rabbits resulted in no deaths. No signs of toxic stress were observed, and all animals gained weight over the 14-day observation periods. Single treatment of 0.5 mL neat jet fuel to rabbit skin produced negative results for skin irritation. Guinea pigs tailed to elicit a sensitization response following repeated applications of the jet fuels. Inhalation vapor exposure to JP-8, JP-8 + 100 (Betz), and JP-8 (Mobil) were determined to be >3.43, >3.52, and >3.57 mg/L, respectively. LD% values for aerosol exposure to JP-8, JP-8 + 100 (Betz), and JP-8 + 100 (Mobil) were >4.44, >4.39, and >4.54 mg/L, respectively. Under the conditions of these tests, the additive packages did not potentiate the acute effects normally associated with JP-8 jet fuel exposures.« less
Skin Diseases: Questions for Your Health Care Provider
Skip Navigation Bar Home Current Issue Past Issues Skin Diseases Questions for Your Health Care Provider Past ... dermatitis worse? What are the most common irritants? Skin cancer What type of skin cancer do I ...
Your skin is your body's largest organ. It covers and protects your body. Your skin Holds body fluids in, preventing dehydration Keeps harmful ... it Anything that irritates, clogs, or inflames your skin can cause symptoms such as redness, swelling, burning, ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hobson, D.W.; Snider, T.H.; Korte, D.W.
1993-05-13
The decontamination safety and efficacy of aqueous solutions of sodium hypochlorite (NaOCl) and calcium hypochlorite Ca(OC1)2 against sulfur mustard (HD) and the organophosphonate O-ethyl S-(2-Diisopropylnmino)-ethyl methylphosphonothioate (VX) were examined in the New Zealand White rabbit. Tests on shaved rabbit dorsa indicated moderate irritation due to either NaOC1 or Ca(OCI)2 at 5 percent but no appreciable irritation at 0.5 percent concentrations. Against VX applied topically on shaved rabbit dorsa, significant protection, as indicated by higher 24-hr median lethality doses, was afforded by 0.5 and 5.0 percent NaOC1. However, when VX was applied either directly into a dermal wound or onto amore » swatch of fabric sampled from battle dress uniform (BDU) and subsequently placed into a wound, only 5.0 percent NaOC1 offered significant protection. Against HD, 0.5 and 5.0 percent NaOC1 were equally effective decontaminants as indexed by dermal lesion areas resulting from 1- to 60-min exposures. Neither NaOC1 solution demonstrated sustained efficacy against HD applied on fabric and placed in wounds.« less
A scanning electron microscopy study of CO2 laser-albumin soldering in the rabbit model.
Levanon, Daniel; Katzir, Abraham; Ravid, Avi
2004-12-01
We sought to assess the rabbit as an experimental animal in the investigation of laser skin soldering. We studied, using the scanning electron microscope (SEM), the surface appearances of experimental incisions made on the rabbit back skin and soldered by CO(2) laser. Laser soldering of incisions in various tissues is a modality of wound healing of a very promising clinical value. At present, more component studies on animals directed at paving the way towards clinical protocols are needed. Surgical incisions on rabbits back skin were bonded using either albumin-assisted CO(2) laser soldering (experimental) or thread suturing (reference). The incisions closed were excised 2, 3, 4, and 5 days postoperatively, and skin surfaces were studied in the SEM. Naked eye inspection and SEM analysis showed that full-length sealing of soldered and sutured incisions was discernible as early as day 2. In the SEM, all incisions were found confluently coated by epidermal cells along the former cut streak. Soldering subserved to bond incisions efficiently, with surface smooth and close to normal skin. On the other hand, the surface of sutured incisions appeared convoluted and its aesthetic quality inferior to that of the former. Some of the days two and three soldered incisions suffered dehiscence on excision, which suggests an incomplete regeneration of tensile strength at this early phase of healing. Sutured incisions tolerated excision, very probably due to the microthread still present in the skin tissue rather than because of breaking strength regained during wound healing. Also, hair stumps re-grown on the skin by day 5 postoperative might impair satisfactory microscopy of bonded incisions. CO(2) laser soldering of incisions on the rabbit back skin effected rapid wound sealing and resulted in smooth scars indistinguishable from normal skin. The rabbit is well suited for this kind of studies, provided that excision of experimental cuts takes place not later than 5 days post-incision so that hair stumps may not grow large enough to jeopardize the quality of scanning electron microscopy.
2003-01-01
dysp = Dyspnea euph = euphoria excitement = excited fib = fibrosis flush face = flush face ftg = fatigue Head = Headache Gidd = giddiness inco...nausea Neck = neck ache nose = irritated nose Pallor Pulm edema= pulmonar y edema Resp sys = Respiratory System skin = irritated skin som = somnolence
In vivo skin penetration of macromolecules in irritant contact dermatitis.
Abdel-Mottaleb, Mona M A; Lamprecht, Alf
2016-12-30
Recently, a selective preferential accumulation of polymeric nanoparticles (in the size range around 100nm) has been observed in the follicular system of dermatitis skin. The present investigation aimed at clearly investigating the effect of irritant contact dermatitis on the barrier permeability for colloidal systems below this size range, namely quantum dots and hydrophilic macromolecules. Irritant dermatitis was induced in mice and the penetrability of quantum dots (5nm) and hydrophilic dextran molecules has been tracked in both healthy and inflamed skin using confocal laser scanning microscopy. The selective accumulation of the quantum dots was clearly observed in inflamed skin while hydrophilic dextran behaved similarly in both healthy and inflamed skin. The therapeutic potential for the transdermal delivery of peptide drugs through inflamed skin has been also tested in rats. Results revealed that the transdermal permeation of insulin and calcitonin was not significantly enhanced in dermatitis compared to healthy skin. On the other side, permeation through stripped skin was significantly higher. However, the effect was limited and shorter compared to the SC injection where t min was 0.5h and 2h with a 70% and 46% reduction in blood glucose levels for the stripped skin and the SC injection respectively. Similarly, t min was 4h and 8h with area under the curve of 161±65% and 350±97% for the stripped skin and the SC injection respectively. In conclusion, the changes in skin permeability accompanied with skin inflammation did not affect its permeability to peptide drugs. Our findings also underline that experiments with the tape stripped skin model as a surrogate for inflamed skin can risk misleading conclusions due to significant difference of skin permeability between the tape stripped skin and inflamed skin. Copyright © 2016 Elsevier B.V. All rights reserved.
Schwitulla, J; Brasch, J; Löffler, H; Schnuch, A; Geier, J; Uter, W
2014-07-01
As previous observations have indicated an inter-relationship between irritant and allergic skin reactions we analysed data of synchronous allergen and sodium lauryl sulfate (SLS) patch tests in terms of a relationship between SLS responsiveness and allergic patch test reactions. To analyse differences in terms of allergen-specific and overall reaction profiles between patients with vs. those without an irritant reaction to SLS. Clinical data of 26 879 patients patch tested from 2008 to 2011 by members of the Information Network of Departments of Dermatology were analysed. After descriptive analyses, including the MOAHLFA index, the positivity ratio and the reaction index, a negative binomial hurdle model was adopted to investigate the correlation between SLS reactivity and positive patch test reactions. Men, patients aged ≥ 40 years and patients with an occupational dermatitis background were over-represented in the SLS-reactive group. Patients with an irritant reaction to SLS showed a higher proportion of weak positive reactions, as well as more questionable and irritant reactions to contact allergens than patients not reactive to SLS. The risk of an additional positive patch test reaction increased by 22% for SLS-reactive patients compared with those who were SLS negative. The marked association between SLS reactivity and the number of positive reactions in patch test patients may be due to nonspecific increased skin reactivity at the moment of patch testing only. However, increased SLS reactivity could also be due to longer-lasting enhanced skin irritability, which may have promoted (poly-)sensitization. Further studies, for example with longitudinal data on patients repeatedly patch tested with SLS and contact allergens, are necessary. © 2014 British Association of Dermatologists.
Sousa, Giovana D; Kishishita, Juliana; Aquino, Kátia A S; Presgrave, Octávio A F; Leal, Leila B; Santana, Davi P
2017-07-01
The aim of this study was to compare the biopharmaceutical characteristics and irritation potentials of microemulsions (MEs) and conventional systems (CSs) containing oil from Syagrus cearensis for topical delivery of Amphotericin B (AmB). Pseudo-ternary phase diagrams were constructed using a water titration method to develop the MEs, and the CSs were prepared according to the classical technique of phase inversion. In the skin permeation and retention study, dermatomed pig skin without stratum corneum was used as an alternative disturbed skin model. The irritation potential was evaluated using three different methods, chorioallantoic membrane assays (HET-CAM and CAM-TBS), and bovine corneal opacity and permeability (BCOP) test. The optimized formulation (ME1) consisting of 0.1% (w/w) Amphotericin B, 9.1% (w/w) catolé oil, 81% (w/w) Smix (1:1, Tween 20 and Kolliphor EL) possessed droplet size of 31.02 ± 0.9 nm, zeta potential of -23.4 mV, and viscosity 0.63 ± 0.1 Pa.s. ME1 exhibited greater retention of AmB in to skin layers (84.79 ± 2.08 μg cm -2 ) than all the others formulations. In general, MEs showed higher drug release and retention than CSs and all of the formulations showed greater retentivity than permeability. Only MEs developed using Labrasol/Plurol Oleique (L/PO) as the surfactant and co-surfactant exhibited a moderate irritation potential; all other MEs and CSs were classified as non-irritants or slight irritants. The results indicate that formulations containing oil from S. cearensis are promising alternatives for the delivery of AmB targeting the treatment of cutaneous leishmaniasis.
Maenthaisong, Ratree; Viyoch, Jarupa; Chaiyakunapruk, Nathorn; Warnnissorn, Prateep
2007-09-01
Cleansing lotion containing extract of tamarind fruit pulp was developed to provide skin a lighter effect. Skin irritation may occur due to keratolytic effect of alpha-hydroxyl acids (AHA) in the tamarind fruit pulp extract. To assess the cumulative irritation effect of cleansing lotion containing tamarind fruit extract with 2% (w/w) tartaric acid on human skin compared with placebo product and de-ionized water. The study design was a single-blinded, randomized side of arm, and controlled study. Three samples, including test product, placebo product, and de-ionized water, were repeatedly applied on the inner forearm of 15 healthy females (aged 28.3 +/- 3.1 years) for 30 min daily for 5 days under semi-occlusive patch. Skin irritation was measured by using visual scoring and instruments such as Tewameter and Mexameter. All measurements were done before application of samples every day from day 1 until day 5. Final measurements were done after the last application for 3 days (day 8). The results obtained from the visual scoring scale indicated no irritation signs and symptoms of test product. Mean differences of transepidermal water loss and erythema values between test product and de-ionized water and between test and placebo products were not statistically significant (P > 0.05). These findings indicate a preliminary safety evidence of our developed cleansing lotion containing the natural AHAs and can be used as cumulative evidence for supporting the future home use study of this product in human.
Kojima, Hajime; Katoh, Masakazu; Shinoda, Shinsuke; Hagiwara, Saori; Suzuki, Tamie; Izumi, Runa; Yamaguchi, Yoshihiro; Nakamura, Maki; Kasahawa, Toshihiko; Shibai, Aya
2014-07-01
Three validation studies were conducted by the Japanese Society for Alternatives to Animal Experiments in order to assess the performance of a skin irritation assay using reconstructed human epidermis (RhE) LabCyte EPI-MODEL24 (LabCyte EPI-MODEL24 SIT) developed by the Japan Tissue Engineering Co., Ltd. (J-TEC), and the results of these studies were submitted to the Organisation for Economic Co-operation and Development (OECD) for the creation of a Test Guideline (TG). In the summary review report from the OECD, the peer review panel indicated the need to resolve an issue regarding the misclassification of 1-bromohexane. To this end, a rinsing operation intended to remove exposed chemicals was reviewed and the standard operating procedure (SOP) revised by J-TEC. Thereafter, in order to confirm general versatility of the revised SOP, a new validation management team was organized by the Japanese Center for the Validation of Alternative Methods (JaCVAM) to undertake a catch-up validation study that would compare the revised assay with similar in vitro skin irritation assays, per OECD TG No. 439 (2010). The catch-up validation and supplementary studies for LabCyte EPI-MODEL24 SIT using the revised SOPs were conducted at three laboratories. These results showed that the revised SOP of LabCyte EPI-MODEL24 SIT conformed more accurately to the classifications for skin irritation under the United Nations Globally Harmonised System of Classification and Labelling of Chemicals (UN GHS), thereby highlighting the importance of an optimized rinsing operation for the removal of exposed chemicals in obtaining consistent results from in vitro skin irritation assays. Copyright © 2013 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, S.R.
The primary aim of this study was to develop non-invasive, physical means to quantitatively assess the epidermal turnover kinetics and barrier properties of the skin and relate these to the cutaneous irritation which results from ultraviolet light irradiation and mold thermal burns. After systematically injecting radiolabeled glycine, the appearance of radioactivity at the skin's surface indicated the transit time of radiolabeled cells through the skin. By plotting the data as the cumulative specific activity against time and then fitting them with a third order polynomial equation, it is possible to estimate the turnover time of the stratum corneum. The skinmore » turnover was coordinated with non-invasive transepidermal water loss (TEWL) studies determined with an evaporimeter. In vitro diffusion studies of the permeability of hydrocortisone through UVB irradiated and thermally burned skin were also performed. The studies indicated that irritated skin offers a relatively low diffusional resistance to hydrocortisone. Depending on the severity of the trauma, the increases in hydrocortisone's permeability coefficient through irritated skin ranged from a low of about 2 times normal to a high of about 210 times normal. Trauma-induced changes in hydrocortisone permeability parallel changes in TEWL, proving that the barrier deficient state resulting from rapid epidermal turnover is a general phenomenon.« less
Primary Eye Irritation of Guanidine Nitrate in Male Rabbits.
1986-01-01
nitrate were indicated by observ;Ition of pannus (I of 6) and corneal erosions (2 of 6) that persisted through termination at day 21. i L0&.. ’- DO I FO7...animals tested showed one or more of these lesions. Potential corrosive properties of guanidine nitrate were indicated by observation of pannus (1 of 6) and...developing pannus . In four rabbits, slight (score I) iritis (vascular injection) was observed. This was noted as early as the i-hour observation and
Yamamoto, Akihiko; Harano, Satomi; Shinya, Noriko; Nagano, Ayataka; Miyatsu, Yoshinobu; Sawabe, Kyouko; Matsumura, Takayuki; Ato, Manabu; Takahashi, Motohide; Taki, Hisashi; Hifumi, Toru
2018-04-01
The redback spider ( Latrodectus hasseltii ) is nonindigenous to Japan but has now spread throughout the country. Bites to humans are rare but can be fatal. We prepared freeze-dried redback spider antivenom for therapeutic use against bites in Japan by immunization of horse plasma. This study included two nonclinical tests of the antivenom: a local irritation study involving a single intramuscular administration to rabbits (with injections of physiological saline and an existing freeze-dried diphtheria antitoxin as control and comparison substances, respectively) and a 2-week repeated intermittent intravenous-dose toxicity study in rats. The irritation study showed the antivenom's irritancy to be comparable with that of the saline and the existing antitoxin preparations under the test conditions. In a repeated-dose toxicity study, no toxicity change was found in male or female rats, and the no-observed-adverse-effect level (NOAEL) was judged to be a dose volume of 20 mL/kg (1082 units/kg antivenom activity) in both male and female rats. In addition, there was no toxicological difference between proteinaceous diphtheria antitoxin and redback spider antivenom prepared to have the same protein content and the same additive composition. Based on these findings, we will further advance our research towards clinical application of the redback spider antivenom. This research was supported by the Research Program on Emerging and Re-emerging Infectious Disease of the Japan Agency for Medical Research and Development.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-08
... exposure. It is a mild eye irritant, slight skin irritant, and is not a dermal sensitizer in guinea pigs... those engaged in the following activities: Crop production (NAICS code 111). Animal production (NAICS...
Draelos, Zoe; Hornby, Sidney; Walters, Russel M; Appa, Yohini
2013-12-01
The addition of hydrophobically modified polymers (HMPs) to cleansers that contain surfactants can create polymer-surfactant complexes that are less irritating to the skin than commercially available mild cleansers. Our objective was to compare the tolerability and efficacy of a test foaming liquid facial cleanser containing HMPs with a commercial liquid nonfoaming facial cleanser in women with sensitive skin. In this randomized, prospective, double-blind, comparative study, women (n = 20 per group) with mild-to-moderate atopic dermatitis (AD), eczema, acne, or rosacea used a test gentle foaming liquid facial cleanser containing HMPs or a commercial gentle liquid nonfoaming facial cleanser daily for 3 weeks. Investigators assessed irritation and skin condition. Study subjects also assessed their skin properties and the performance of each cleanser. Clinicians as well as study subjects consistently rated the test cleanser as effective or slightly more effective at improving symptoms than the commercial cleanser, although no significant differences between groups were observed. At weeks 1 and 3, respectively, more users of the commercial cleanser reported irritation (20% and 10%) than users of the test cleanser (5% and 5%). In addition, subject self-assessments of skin condition and cleansing properties were slightly more improved with the test cleanser than with the commercial cleanser. Both the test foaming cleanser containing HMPs and the commercial nonfoaming cleanser were effective and well accepted by most women in the study. Improvements were observed by both clinicians and subjects in the group using the test cleanser containing HMPs in all evaluated skin categories. © 2013 The Authors Journal of Cosmetic Dermatology Published by Wiley Periodicals, Inc.
Chandrashekar, N S; Hiremath, Shobha Rani Rajeev
2008-04-01
Using skin as a port for systemic drug administration, transdermal drug delivery has expanded greatly over the last two decades. Our aim was to formulate the single layer drug-in-adhesive transdermal patch for 6-mercaptopurine (6-MP). In vitro permeation study was carried out using modified Franz diffusion cell with and without of different concentration of d-limonene in human cadaver skin. In vivo immunomodulatory was carried out in mice, cumulative skin irritation, sensitization and patch adherence study was done in both mice and human subjects. 6-MP flux increased from 43+/-12.2 microg/cm2h (control) to 162.8+/-32.2 microg/cm2h (6% w/v d-limonene) data was significant (p<0.05), with decrease in the lag time to 35+/-9.3 min compared to control of 90 +/-15.3 min. In vivo immunomodulatory effect was shown in the Balb/c mice with 100 mumol/kg/body wt of animal for 5d (one dose/d) of d-limonene. WBC count of 13469 cells/mm peak was observed on 12th day, bone marrow cells of 26.3 x 10(6) cells/femur and alpha-esterase positive cells of 1259+/-328.4 cells/4000 bone marrow cells. Cumulative skin irritation, sensitisation and patch adherence in animals and human subjects showed no skin irritation and sensitization. Patch adhesion was greater than 90.0% respectively in both human subjects and mice. The percentage of human subjects with adhesive residue was significantly less with scores of zero. d-Limonene proved as good chemical enhancer by increasing in the skin permeability with shortened the lag time. It proved that therapeutic amount of 6-MP can be delivered through transdermal drug delivery.
Short contact therapy of acne with tretinoin.
Veraldi, Stefano; Barbareschi, Mauro; Benardon, Susanna; Schianchi, Rossana
2013-10-01
The most frequent side effect of topical retinoids is irritant contact dermatitis. It occurs in approximately 85% of patients; the percentage can reach up to 95% in patients treated with tretinoin. Severity of this dermatitis is moderate to severe in approximately 20% of patients. However, 15% of patients stop the treatment with tretinoin because of skin irritation. The authors used tretinoin as short contact therapy (SCT) in mild to moderate acne, in order to try to reduce the incidence and severity of irritant contact dermatitis. They present the final results of a sponsor-free, pilot, open, multicenter study. Seventy-four patients were treated with 0.05% tretinoin cream. It was applied once daily for 30 min. Treatment duration ranged from 8 to 32 weeks (mean duration: 12 weeks). Acne severity and treatment efficacy were evaluated by means of the Global Acne Grading System. A significant clinical improvement (≥50% from baseline) was observed in 41 patients (55.4%). Thirteen patients (17.6%) developed a mild skin irritation. Four patients (5.4%) stopped the treatment because of severe skin irritation. Efficacy of tretinoin used as SCT seems to be superimposable to that of tretinoin used according to standard modality. Tolerability of SCT with tretinoin is very good. This tolerability allows a high adherence of patients to the treatment and it markedly improves compliance.
Johnson, Victor J; Auerbach, Scott S; Luster, Michael I; Waidyanatha, Suramya; Masten, Scott A; Wolfe, Mary S; Burleson, Florence G; Burleson, Gary R; Germolec, Dori R
2017-07-01
4-Methylcyclohexanemethanol (MCHM) is a flotation reagent used in fine coal beneficiation. On January 9, 2014, crude MCHM, a mixture containing predominantly MCHM, was inadvertently released into the Elk River, a municipal water source that serves about 300,000 people in the Charleston, WV area, resulting in temporary contamination of 15 percent of the state's tap water and causing significant dermal exposure. The current studies were undertaken to determine whether crude MCHM or MCHM has the potential to produce dermal irritancy and/or sensitization. BALB/c female mice were treated daily for 3 consecutive days by direct epicutaneous application of 25 μL of various concentrations of crude MCHM or MCHM to the dorsum of each ear. A mouse ear-swelling test was used to determine irritancy potential and was undertaken in combination with the standardized Local Lymph Node Assay (LLNA) to determine skin sensitizing potential. MCHM was found to produce skin irritation at concentrations above 20% and did not produce sensitization. Crude MCHM also produced irritation, although weaker, and in addition was found to be a weak to moderate skin sensitizer. The results are discussed in terms of potential human health hazard. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dover, Sara E.; Aroutcheva, Alla A.; Faro, S.; Chikindas, Michael L.
2007-01-01
Objective. To evaluate the safety of the antimicrobial peptide, lactocin 160. Methods. Lactocin 160, a product of vaginal probiotic Lactobacillus rhamnosus 160 was evaluated for toxicity and irritation. An in vitro human organotypic vaginal-ectocervical tissue model (EpiVaginal) was employed for the safety testing by determining the exposure time to reduce tissue viability to 50% (ET-50). Hemolytic activity of lactocin160 was tested using 8% of human erythrocyte suspension. Susceptibility of lactobacilli to lactocin160 was also studied. Rabbit vaginal irritation (RVI) model was used for an in vivo safety evaluation. Results. The ET-50 value was 17.5 hours for lactocin 160 (4.9 hours for nonoxynol 9, N9). Hemolytic activity of lactocin 160 was 8.2% (N9 caused total hemolysis). Lactobacilli resisted to high concentrations of peptide preparation. The RVI model revealed slight vaginal irritation. An average irritation index grade was evaluated as “none.” Conclusions. Lactocin 160 showed minimal irritation and has a good potential for intravaginal application. PMID:18273406
Gentle cleansing and moisturizing for patients with atopic dermatitis and sensitive skin.
Cheong, Wai Kwong
2009-01-01
Atopic dermatitis is a common condition characterized by pruritus, inflammation, and dryness of the skin. Inflammation disrupts the barrier function of the stratum corneum, predisposing the skin to be dry, and increases susceptibility to irritants and secondary bacterial infection. Sensitive skin is common, reported by 40-50% of women and 30% of men in the US, Europe, and Japan. Basic requirements in managing eczema and sensitive skin include effective cleansers that do not compromise skin barrier integrity, alleviation of skin dryness, and restoration of skin barrier function through the use of therapeutic moisturizers. The selection of a skin cleanser is therefore an important part of managing these conditions. Studies have reported clinical improvement with the use of soap-free cleansers in combination with topical treatments. While topical corticosteroids and immunosuppressive agents are mainstays of treatment for atopic dermatitis, therapeutic moisturizers are important adjuncts. Moisturizers improve skin hydration, reduce susceptibility to irritation, restore the integrity of the stratum corneum, and enhance the efficacy of topical corticosteroids.
Stoma dermatitis: prevalent but often overlooked.
Agarwal, Shilpa; Ehrlich, Alison
2010-01-01
Peristomal dermatoses commonly afflict the area around stoma openings in ostomy patients. These complications, however, are often unreported by patients and remain untreated for years, thus affecting maintenance and recovery from the surgery. These dermatoses can have chemical, mechanical, irritant, bacterial, immunologic, or disease-related etiologies. Examples of common forms of dermatitis that occur peristomally include fecal or urine irritant contact dermatitis, chronic papillomatous dermatitis, mechanical dermatitis, and allergic contact dermatitis. This article summarizes various skin irritations that can occur after an ostomy and also reviews previously published reports of peristomal allergic contact dermatitis. In addition, the clinical importance of identifying these dermatoses (most important, their effects on the patient's quality of life), risk factors for the skin irritations, the importance of patch testing, treatment of stoma dermatitis, and the importance of patient education and patient-doctor communication are also discussed.
Werb, Z; Reynolds, J J
1975-01-01
1. The immunological cross-reactivity between rabbit collagenases from a variety of normal and pathological sources was examined. The specific antibody raised against collagenase secreted from normal rabbit synovial fibroblasts gave reactions of complete identity with collagenases secreted from fibroblasts derived from rabbit skin, and from synovium from experimentally arthritic rabbits. 2. The rabbit fibroblast collagenase was immunologically identical with collagenases obtained from the organ culture medium of normal rabbit skin, synovium, ear fibrocartilage and subchondral bone. 3. Collagenases from the culture media of normal rabbit synovium and from hyperplastic synovium of rabbits made experimentally arthritic were identical. 4. The collagenase secreted from rabbit fibroblasts gave a reaction completely identical with that of a collagenase extracted directly from a rabbit carcinoma. 5. IgG (immunoglobulin G) from a specific antiserum to rabbit fibroblast collagenase was a potent inhibitor of the collagenases obtained from the culture media of the various rabbit cells and tissues. 6. Collagenases from human synovium and from mouse macrophages and bone were neither precipitated nor inhibited by antibodies to rabbit collagenase. 7. No immunoreactive material was found in lysates of rabbit polymorphonuclear leucocyte granules with the specific antisera to rabbit fibroblast collagenase. No evidence for inactive forms of rabbit collagenase in lysates of the rabbit synovial fibroblasts could be found, either by double immunodiffusion against the specific collagenase, or by displacement of active enzyme from inhibition by the IgG. Images PLATE 1 PMID:56176
2013-01-01
Background Many natural products used in preventive medicine have also been developed as cosmeceutical ingredients in skin care products, such as Scutellaria baicalensis and Gardenia jasminoides. Norartocarpetin is one of the antioxidant and antityrosinase activity compound in Artocarpus communis; however, the cytotoxicity, skin irritation and antimelanogenesis mechanisms of norartocarpetin have not been investigated yet. Methods In the present study, cell viability in vitro and skin irritation in vivo are used to determine the safety of norartocarpetin. The melanogenesis inhibition of norartocarpetin was determined by cellular melanin content and tyrosinase in B16F10 melanoma cell. Moreover, we examined the related-melanogenesis protein by western blot analysis for elucidating the antimelanogenesis mechanism of norartocarpin. Results The result of the present study demonstrated that norartocarpetin not only present non-cytotoxic in B16F10 and human fibroblast cells but also non-skin irritation in mice. Moreover, our result also first found that norartocarpetin downregulated phospho-cAMP response element-binding (phospho-CREB) and microphthalmia-associated transcription factor (MITF) expression, which in turn decreased both synthesis of tyrosinases (TRP-1 and TRP-2) and cellular melanin content. This process is dependent on norartocarpetin phosphorylation by mitogen-activated protein kinases such as phospho-JNK and phospho-p38, and it results in decreased melanogenesis. Conclusion The present study suggests that norartocarpetin could be used as a whitening agent in medicine and/or cosmetic industry and need further clinical study. PMID:24325567
A study of the human skin-whitening effects of resveratryl triacetate.
Ryu, Ja Hyun; Seok, Jin Kyung; An, Sang Mi; Baek, Ji Hwoon; Koh, Jae Sook; Boo, Yong Chool
2015-04-01
Resveratrol has a variety of bioactivities that include its anti-melanogenic effects, but its use in cosmetics has been challenging partly because of its chemical instability. Resveratryl triacetate (RTA) is a prodrug that can enhance stability. The purpose of this study was to examine the skin safety and whitening effects of RTA in human subjects. The primary skin irritation potentials of RTA and resveratrol were tested at 0.1 and 0.5 % on human subjects. Resveratrol at a concentration of 0.5 % induced weak skin irritation, whereas RTA did not induce any skin responses. The skin-whitening efficacy of a cosmetic formulation containing 0.4 % RTA was evaluated in two different test models. In the artificial tanning model, the test product and the control product were applied twice daily to the skin of the forearms of 22 human subjects after pigmentation induction by ultraviolet irradiation. Applying the test and the control products to the artificial tanning model for 8 weeks increased the individual topology angles (ITA°) by 17.06 and 13.81 %, respectively, a difference that was statistically significant (p < 0.05). In the hyperpigmentation model, the test product and the control product were applied twice daily to the faces of 21 human subjects. The averaged intensity of the hyperpigmented spots decreased by 2.67 % in the test group and 1.46 % in the control group, a difference that was statistically significant (p < 0.05). Therefore, RTA incorporated into cosmetic formulations can whiten human skin without inducing skin irritation.
Papadatou, Zoi; Cooper, Kay; Klein, Susan; MacDuff, Colin; Steiner, Markus
2016-10-01
The objective of this quantitative systematic review is to identify, appraise and synthesize the best available evidence on the effectiveness of moisturizers, barrier creams, protective gloves, skin protection education and complex interventions (a combination of two or more of the interventions listed) in preventing occupational irritant hand dermatitis (OIHD) in wet workers. These interventions will be compared to an alternative intervention or to usual care (workers regular skin care regime). The specific review question is: "What is the effectiveness of moisturizers, barrier creams, protective gloves, skin protection education and complex interventions in preventing OIHD in wet workers?"
2014-09-19
Biofuels AB; the original formula (SB ATJ SPK (old)) and the current version (SB ATJ SPK (new)) were both tested. A score of moderately irritating, as...10021 with additives). The remaining two ATJ SPK fuels were produced by Swedish Biofuels AB (Stockholm); the original formula (SB ATJ SPK (old), POSF...original formula , SB ATJ SPK (old) (POSF 5668 (alone); 10234 with additives) was provided for testing in 2010. The aromatic content of this fuel consists
Dermal microdialysis of inflammatory markers induced by aliphatic hydrocarbons in rats
Patlolla, Ram R.; Mallampati, Ramya; Fulzele, Suniket V.; Babu, R. Jayachandra; Singh, Mandip
2010-01-01
In the present study we made an attempt to understand the skin irritation cascade of selected aliphatic hydrocarbons using microdialysis technique. Microdialysis probes were inserted into dermis in the dorsal skin of hairless rats. After 2 h of probes insertion, occlusive dermal exposure (2 h) was carried out with 230 μl of nonane, dodecane and tetradecane, using Hill top chambers®. Inflammatory biomarkers such as substance P (SP), α-melanocyte stimulating hormone (α-MSH) Interleukin 6 (IL-6) and prostaglandin E2 (PGE2) were analyzed in the dialysis samples by enzyme immunoassay (EIA). SP, α-MSH and IL6 were released in significant amounts following the dermal exposure of nonane and dodecane, whereas tetradecane did not induce any of these markers in significant amounts compared to control. Nonane increased the PGE2 levels in significant amounts within 2 h of chemical exposure compared to dodecane and tetradecane. IL-6 response was found to be slow and 2–3-fold increase in IL-6 levels was observed after 5 h following nonane and dodecane application. The magnitude of skin irritation exerted by all three chemicals was in the order of nonane ≥ dodecane ≥ tetradecane. The results demonstrate that microdialysis can be used to measure the inflammatory biomarkers in the skin irritation studies and irritation response of chemicals was quantifiable by this method. In conclusion, microdialysis was found to be an excellent tool to measure several inflammatory biomarkers as a function of time after dermal exposures with irritant chemicals. PMID:19152832
Raza, Kaisar; Singh, Bhupinder; Mahajan, Anadi; Negi, Poonam; Bhatia, Amit; Katare, O P
2011-05-01
Capsaicin, extracted from the fruits of Capsicum, is a powerful local stimulant with strong rubifacient action, devoid of vesication. Topical use of capsaicin is quite common in the treatment of various pain-associated musculo-skeletal disorders, itching and neuropathy. Despite its high pharmacodynamic potential, the patient compliance to the drug is reported to be poor owing to multiple skin problems like irritation, burning sensation, and erythma. The present study targets the encasement of drug in the interiors of flexible membrane vesicles (FMVs), as these are reported to have better penetration in the deeper layers of skin, thus leading to enhanced localization of drug and consequently, decreased skin irritation. Multilamellar drug-loaded FMVs, prepared by thin-film hydration were evaluated for their efficacy in vitro and in vivo. When compared with conventional liposomes, the formulated FMVs showed higher skin retention during ex vivo permeation studies employing LACA mice skin, higher analgesic potential using radiant tail-flick method in mice, and better flexibility in regaining their size. Being less of an irritant, these vesicular carriers were also found to be more comfortable on human skin. Thus, the capsaicin-loaded FMVs offer high potential as topical drug delivery technologies with improved patient acceptance and effectiveness.
Formulation and Characterization of Benzoyl Peroxide Gellified Emulsions
Thakur, Naresh Kumar; Bharti, Pratibha; Mahant, Sheefali; Rao, Rekha
2012-01-01
The present investigation was carried out with the objective of formulating a gellified emulsion of benzoyl peroxide, an anti-acne agent. The formulations were prepared using four different vegetable oils, viz. almond oil, jojoba oil, sesame oil, and wheat germ oil, owing to their emollient properties. The idea was to overcome the skin irritation and dryness caused by benzoyl peroxide, making the formulation more tolerable. The gellified emulsions were characterized for their homogeneity, rheology, spreadability, drug content, and stability. In vitro permeation studies were performed to check the drug permeation through rat skin. The formulations were evaluated for their antimicrobial activity, as well as their acute skin irritation potential. The results were compared with those obtained for the marketed formulation. Later, the histopathological examination of the skin treated with various formulations was carried out. Formulation F3 was found to have caused a very mild dysplastic change to the epidermis. On the other hand, the marketed formulation led to the greatest dysplastic change. Hence, it was concluded that formulation F3, containing sesame oil (6%w/w), was the optimized formulation. It exhibited the maximum drug release and anti-microbial activity, in addition to the least skin irritation potential. PMID:23264949
Daftarian, Helga S; Lushniak, Boris D; Reh, Christopher M; Lewis, Daniel M
2002-12-01
Toluene diisocyanate, or TDI (CAS 584-84-9) is a well-known asthmagen and respiratory irritant. TDI is also known for its ability to irritate the skin and mucous membranes. To further investigate the dermal effects of TDI, NIOSH investigators conducted a cross-sectional study at a flexible foam manufacturing plant. A total of 114 workers participated in the study. Participants completed a medical questionnaire, provided blood for antibody testing to TDI and other allergens, and a subset of participants reporting skin symptoms underwent skin patch testing to a standard diisocyanate panel. Production line workers were more than twice as likely to report skin problems as those working in nonproduction areas (PRR = 2.66; 95% CI = 1.14-16.32; P = 0.02). Age, gender and duration of employment at the plant were comparable among participants working in production and nonproduction areas. Of the 100 participants who provided blood samples for antibody testing, specific IgG antibody to TDI was detected in two individuals, and none of the samples demonstrated specific IgE antibody to TDI. Of the 26 workers who underwent skin patch testing, none developed reactions to the diisocyanate allergens. These results suggest that the skin symptoms among study participants represent an irritant rather than an immunologic reaction to TDI, or to an unidentified allergen present in the foam.
Newswanger, Brett; Ammons, Steve; Phadnis, Neelima; Ward, W. Kenneth; Castle, Jessica; Campbell, Robert W.
2015-01-01
Background: Despite a vigorous research effort, to date, the development of systems that achieve glucagon stability in aqueous formulations (without reconstitution) has failed to produce any clinical candidates. We have developed a novel, nonaqueous glucagon formulation based on a biocompatible pharmaceutical solvent, dimethyl sulfoxide, which demonstrates excellent physical and chemical stability at relatively high concentrations and at high temperatures. Methods: This article reports the development of a novel, biocompatible, nonaqueous native human glucagon formulation for potential use in subcutaneous infusion pump systems. Results: Data are presented that demonstrate physical and chemical stability under presumed storage conditions (>2 years at room temperature) as well as “in use” stability and compatibility in an Insulet’s OmniPod® infusion pump. Also presented are results of a skin irritation study in a rabbit model and pharmacokinetics/pharmacodynamics data following pump administration of glucagon in a diabetic swine model. Conclusions: This nonaqueous glucagon formulation is suitable for further clinical development in pump systems. PMID:25550410
Newswanger, Brett; Ammons, Steve; Phadnis, Neelima; Ward, W Kenneth; Castle, Jessica; Campbell, Robert W; Prestrelski, Steven J
2015-01-01
Despite a vigorous research effort, to date, the development of systems that achieve glucagon stability in aqueous formulations (without reconstitution) has failed to produce any clinical candidates. We have developed a novel, nonaqueous glucagon formulation based on a biocompatible pharmaceutical solvent, dimethyl sulfoxide, which demonstrates excellent physical and chemical stability at relatively high concentrations and at high temperatures. This article reports the development of a novel, biocompatible, nonaqueous native human glucagon formulation for potential use in subcutaneous infusion pump systems. Data are presented that demonstrate physical and chemical stability under presumed storage conditions (>2 years at room temperature) as well as "in use" stability and compatibility in an Insulet's OmniPod(®) infusion pump. Also presented are results of a skin irritation study in a rabbit model and pharmacokinetics/pharmacodynamics data following pump administration of glucagon in a diabetic swine model. This nonaqueous glucagon formulation is suitable for further clinical development in pump systems. © 2015 Diabetes Technology Society.
Wyatt, Jeffrey D; Moorman-White, Diane M; Ventura, Donnalee; Schneider, Brett W; Bittner, Thomas W
2017-10-01
International animal welfare organizations and federal, regional, and institutional oversight bodies encourage social housing of gregarious species, such as New Zealand white rabbits (Oryctolagus cuniculus), to promote animal wellbeing in research, teaching, testing and farming settings. At our institution, 2 groups of female New Zealand white rabbits (approximate age, 11 wk; mean weight, 2.35 kg), compatibly paired at the vendor for 5 wk, were paired in caging or group-housed in a floor pen. The rabbits appeared compatible, demonstrating primarily affiliative behaviors throughout 6 wk of daily observations. However, occult aggression that occurred between daily observations or nocturnally resulted in skin wounding. The skin injuries, first identified during prestudy clipping of fur from the back of each rabbit 6 wk after arrival, disqualified every animal from participation in skin toxicology and muscle implantation studies. Success meeting scientific research requirements while promoting animal welfare and health when socially housing New Zealand white rabbits requires examining the behavioral repertoire of their wild counterparts, European rabbits. Factors including age, sex, and housing density influence territoriality, dominance hierarchy, social ranking, and natural, agonistic, injurious, behavioral tendencies. IACUC and other relevant oversight bodies, researchers, and animal care staff should consider this case study and the species-specific natural history of New Zealand white rabbits when assessing the harm and benefit of social housing in regard to research utility and animal welfare.
Guo, Xiang; Yang, Xing Fen; Yang, Ying; Hans, Raabe; Cai, Jing Heng; Xue, Jin Yu; Tan, Xiao Hua; Xie, Xiao Ping; Xiong, Xi Kun; Huang, Jun Ming
2012-06-01
This study aims to establish and evaluate the methodology of isolated rabbit eye (IRE) test. IRE test was performed according to modifications of the in vitro toxicology (INVITTOX) Protocol No.85: Rabbit enucleated eye test by European Centre for the Validation of Alternative Methods (ECVAM), and then 26 chemicals and 26 cosmetic products were tested in both in vitro IRE and in vivo Draize tests. A statistical analysis was conducted to determine the relevance of the IRE test to the data generated in the Draize test. IRE test was established successfully in our laboratory. It was shown that ranking correlation and class concordance were fairly well between the IRE test and the Draize test for 26 reference chemicals (Fisher's Exact Test χ(2)=51.314, P<0.001; McNemar P=0.261; Gamma=0.960, P<0.001; Kappa=0.843, P<0.001) and 26 cosmetic products (Fisher's Exact Test χ(2)=15.522, P<0.001; McNemar P=0.311; Gamma=0.967, P<0.001; Kappa=0.611, P<0.001). IRE test was established successfully for in vitro testing of eye irritation as an alternative to Draize test. Copyright © 2012 The Editorial Board of Biomedical and Environmental Sciences. Published by Elsevier B.V. All rights reserved.
Primary Ocular Irritation Potential of Nitrosoguanidine in Male Rabbits
1989-09-01
Markedly deepened rugae , congestion, swelling, moderate circumirldial hyperemia or injection, any of these or any combination thereof, iris still...of the normal luster); inflammation of the iris (other than a slight deepening of the rugae or a slight hyperemia of the circumcomeal blood yessels
Primary Eye Irritation Potential of DIGL-RP Solid Propellant in Rabbits
1989-10-01
0 Markedly deepened rugae , congestion, swelling., moderate circumiddial ".,peremia o. injection, any of these or...of the Iris (other than a slight deepening of the rugae or a slight hyperemia of the clrcumcomeal blood vessels); an obvious swelling in the
Protection afforded by controlled application of a barrier cream: a study in a workplace setting.
Sadhra, S S; Kurmi, O P; Mohammed, N I; Foulds, I S
2014-10-01
Skin protective creams (PCs) are used widely in industrial work environments to prevent irritant contact dermatitis. However, workplace studies remain equivocal in terms of their effectiveness, which may be partly owing to whether the PC remains on the skin. To assess the practicability of using skin occlusion testing in a workplace as a method to determine whether PCs applied under controlled conditions can reduce skin damage against known irritants. This study also compares two methods of skin evaluation: clinical dermatological assessment and bioengineering techniques. Daily occlusion testing for 1 h (over two consecutive weeks) was conducted in an engineering company on the volar forearm of 21 healthy volunteer engineers with sodium lauryl sulfate (SLS) and a PC that was used on site. The engineers conducted their normal work activities during the occlusion testing period. The skin areas tested were assessed using transepidermal water loss (TEWL), Chroma Meter and by visual dermatological scoring. Testing with PC and SLS together showed that PC does not prevent irritant contact dermatitis but significantly reduced skin damage compared with SLS alone (P < 0.01). The changes in skin were evident earlier with the biophysical measurements when compared with the dermatological assessment. Occlusion testing is a useful method for assessing the potential effectiveness of protective creams and can be used in a workplace without affecting work practices. TEWL and the Chroma Meter provide useful objective information and should be used in combination with dermatological examinations. © 2014 British Association of Dermatologists.
Rahman, Salwa Abdel; Abdelmalak, Nevine Shawky; Badawi, Alia; Elbayoumy, Tahany; Sabry, Nermeen; El Ramly, Amany
2015-01-01
Tretinoin (TRT) is a widely used retinoid for the topical treatment of acne, photo-aged skin, psoriasis and skin cancer which makes it a good candidate for topical formulation. Yet side effects, like redness, swelling, peeling, blistering and, erythema, in addition to its high lipophilicity make this challenging. Therefore, the aim of this study was the development of TRT-loaded proniosomes to improve the drug efficacy and to increase user acceptability and compliance by reducing its side effects. Nine formulae were prepared according to 3(2) factorial design and were evaluated for their morphology, vesicle size, entrapment efficiency (EE %), and% of drug released after 5 h. Hydrogel of the candidate formula, N8G (proniosomes prepared with 0.025% TRT, and Span60: cholesterol molar ratio of 3:1 and incorporated in 1% carbopol gel) was developed and evaluated for skin irritation test and clinical study in acne patients compared to marketed product. Candidate formula showed higher efficacy and very low irritation potential when compared to marketed product in human volunteers.
Putting copper into action: copper-impregnated products with potent biocidal activities.
Borkow, Gadi; Gabbay, Jeffrey
2004-11-01
Copper ions, either alone or in copper complexes, have been used for centuries to disinfect liquids, solids, and human tissue. Today copper is used as a water purifier, algaecide, fungicide, nematocide, molluscicide, and antibacterial and antifouling agent. Copper also displays potent antiviral activity. We hypothesized that introducing copper into clothing, bedding, and other articles would provide them with biocidal properties. A durable platform technology has been developed that introduces copper into cotton fibers, latex, and other polymeric materials. This study demonstrates the broad-spectrum antimicrobial (antibacterial, antiviral, antifungal) and antimite activities of copper-impregnated fibers and polyester products. This technology enabled the production of antiviral gloves and filters (which deactivate HIV-1 and other viruses), antibacterial self-sterilizing fabrics (which kill antibiotic-resistant bacteria, including methicillin-resistant Staphylococcus aureus and vancomycin-resistant Enterococci), antifungal socks (which alleviate symptoms of athlete's foot), and anti-dust mite mattress covers (which reduce mite-related allergies). These products did not have skin-sensitizing properties, as determined by guine pig maximization and rabbit skin irritation tests. Our study demonstrates the potential use of copper in new applications. These applications address medical issues of the greatest importance, such as viral transmissions; nosocomial, or healthcare-associated, infections; and the spread of antibiotic-resistant bacteria.
Onoue, Kaoru; Yagi, Yasuo; Pressman, David
1966-01-01
Multiple antibody components of rabbit antisera against p-azobenzenearsonate (Rp) were studied with respect to their globulin nature and skin-sensitizing activity. IgA antibody was characterized by isolating two IgA-rich fractions from a specifically purified antibody preparation. Examination of these fractions showed that IgA antibodies existed in two molecular forms, one with a sedimentation constant of 7S and the other 9S. Skin-sensitizing activity was examined by a P-K type test and a PCA test with Rp-rabbit serum albumin in homologous (rabbit) species. Only the 7S but not 9S IgA antibody sensitized rabbit skin. IgM antibody showed no activity and IgG antibody showed very low activity. In contrast, only IgG antibody was active in the P-K type test to sensitize a heterologous species (guinea pig). None of the antibodies of other classes showed sensitizing activity in heterologous skin. The 7S IgA antibody lost its sensitizing activity upon reduction and alkylation, although no change in its molecular size could be observed. The loss of sensitizing activity was not due to the destruction of antigen-binding activity since the treated 7S IgA antibody retained this activity as shown by radioimmunoelectrophoresis and by binding to the specific immunoadsorbent. The 9S IgA antibody was more resistant to these treatments than the IgM antibody and showed no indication of dissociation. The treated 9S IgA also retained antigen-binding activity. Both the P-K type and PCA reactions were considerably stronger when the interval between injections of antibody and antigen was 24 hr rather than 4 to 5 hr. PMID:4159250
Goreshi, Renato; Samrao, Aman; Ehst, Benjamin D
2012-12-01
The use of topical medications for acne vulgaris is often limited by their irritant properties. Newer combination preparations are available and offer convenience, but irritant potential may still be a hindrance, perhaps more so with the combination of 2 agents. Few studies have compared these formulations directly for tolerability. We sought to compare the tolerability of 2 combination topical acne products, clindamycin 1.2%-tretinoin 0.025% (CLIN/RA) gel and benzoyl peroxide 2.5%-adapalene 0.1% (BPO/ADA) gel. CLIN/RA and BPO/ADA were applied daily to opposite sides of a subject's face for 21 days in a double-blinded fashion. Investigators' Global Assessments and study subject self-assessments of burning/stinging, itching, erythema, and dryness/scaling were collected. Transepidermal water loss (TEWL) was also measured as an objective measure of skin irritation. A mixed model analysis and repeated-measures analysis of variance were used to compare outcomes for both acne formulations. CLIN/RA produced significantly less burning/stinging than BPO/ADA (P<.001) as well as significantly less pruritus than BPO/ ADA (P<.001). BPO/ADA caused significantly more TEWL than CLIN/RA (P=.005). There was no significant difference in the amount of erythema or the amount of dryness/scaling caused by either formulation. CLIN/RA produced significantly less skin irritancy and TEWL than BPO/ADA.
Williams, C; Wilkinson, M; McShane, P; Pennington, D; Fernandez, C; Pierce, S
2011-06-01
Healthcare-associated infection is an important worldwide problem that could be reduced by better hand hygiene practice. However, an increasing number of healthcare workers are experiencing irritant contact dermatitis of the hands as a result of repeated hand washing. This may lead to a reduced level of compliance with regard to hand hygiene. To assess whether a measure of acute irritation by hand soaps could predict the effects of repeated usage over a 2-week period. In a double-blind, randomized comparison study, the comparative irritation potential of four different hand soaps was assessed over a 24-h treatment period. The effect of repeated hand washing with the hand soap products over a 2-week period in healthy adult volunteers on skin barrier function was then determined by assessment of transepidermal water loss (TEWL), epidermal hydration and a visual assessment using the Hand Eczema Severity Index (HECSI) at days 0, 7 and 14. A total of 121 subjects from the 123 recruited completed phase 1 of the study. All four products were seen to be significantly different from each other in terms of the irritant reaction observed and all products resulted in a significantly higher irritation compared with the no-treatment control. Seventy-nine of the initial 121 subjects were then enrolled into the repeated usage study. A statistically significant worsening of the clinical condition of the skin as measured by HECSI was seen from baseline to day 14 in those subjects repeatedly washing their hands with two of the four soap products (products C and D) with P-values of 0·02 and 0·01, respectively. Subclinical assessment of the skin barrier function by measuring epidermal hydration was significantly increased from baseline to day 7 after repeated hand washing with products A, B and D but overall no significant change was seen in all four products tested by day 14. A statistically significant increase in TEWL at day 14 was seen for product A (P = 0·02) indicating a worsening of skin barrier function. This effect was also seen initially for product D at day 7 although this was then lost at day 14. Further regression analysis was then performed to see if the acute irritant test data for each product correlated with the skin barrier data from the repeated usage component of the study. This showed that the results of acute irritant testing of the individual products did not predict the results of chronic use of hand soaps. The results from phase 2 of our study confirm the work of previous studies that show that regular exposure to irritants in daily life leads to stratum corneum damage and impairment of the skin barrier. Although significant differences were seen between the products in phase 1 of the study, regression analysis showed that the results of patch testing of the individual products did not predict the results of chronic use of hand soaps. When designing a study to assess the effects of cumulative use of a product on the skin, the study should mirror the use conditions of the product as closely as possible. © 2011 The Authors. BJD © 2011 British Association of Dermatologists.
Kobayashi, Scott D; Malachowa, Natalia; Whitney, Adeline R; Braughton, Kevin R; Gardner, Donald J; Long, Dan; Bubeck Wardenburg, Juliane; Schneewind, Olaf; Otto, Michael; Deleo, Frank R
2011-09-15
Community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) infections are frequently associated with strains harboring genes encoding Panton-Valentine leukocidin (PVL). The role of PVL in the success of the epidemic CA-MRSA strain USA300 remains unknown. Here we developed a skin and soft tissue infection model in rabbits to test the hypothesis that PVL contributes to USA300 pathogenesis and compare it with well-established virulence determinants: alpha-hemolysin (Hla), phenol-soluble modulin-alpha peptides (PSMα), and accessory gene regulator (Agr). The data indicate that Hla, PSMα, and Agr contribute to the pathogenesis of USA300 skin infections in rabbits, whereas a role for PVL could not be detected.
... AND AIRWAYS Breathing difficulty (from breathing in the chlorinated lime) Throat swelling (which may also cause breathing difficulty) SKIN Burns Holes (necrosis) in the skin or tissues underneath Irritation
Rajkumar, S; Jebanesan, A
2010-03-01
Plant based repellent against mosquito borne diseases are used recently because synthetic repellents cause side effects like breathing problem, eye irritation, head ache, cough, etc. The use of natural products for dengue control would protect the environment, reduce dependence on expensive synthetic repellents and also generate local employment. Essential oil was isolated by steam distillation which was used against the bites of Aedes aegypti and duration of protection period was assessed. Skin-irritant potential test was also conducted on 25 healthy volunteers by using four-point scale. The increase in the concentrations of essential oil increased the mean protection time against the bites of Aedes aegypti. The lowest mean protection time was 180.0 min for 2.5% and highest time of 255.0 min for 10%. The mean score of zero for skin-irritant potential test for all the concentrations indicated that the essential oil did not cause irritation to human skin. Results indicated that the use of plant based repellent for the control of dengue fever would replace the currently used synthetic repellents which causes many side effects.
de Ávila, Renato Ivan; de Sousa Vieira, Marcelo; Gaeti, Marilisa Pedroso Nogueira; Moreira, Larissa Cleres; de Brito Rodrigues, Laís; de Oliveira, Gisele Augusto Rodrigues; Batista, Aline Carvalho; Vinhal, Daniela Cristina; Menegatti, Ricardo; Valadares, Marize Campos
2017-02-01
A new molecule, LQFM048, originally designed through molecular hybridization using green chemistry approach, is in development as a photoprotective agent. Eye irritation, skin toxicity and genotoxicity evaluations are mandatory for predicting health risks. In this context, the purpose of this study was to investigate the eye irritation potential of LQFM048 by combining Short Time Exposure (STE), Bovine Corneal Opacity and Permeability (BCOP) associated with corneal histomorphometry and Hen's Egg Test-Chorioallantoic Membrane (HET-CAM). Additionally, skin toxicity was evaluated by interleukin-18 production in the HaCaT keratinocyte, Local Lymph Node Assay (LLNA:BrdU-ELISA) method, 3T3 Neutral red uptake (NRU) assay and in vivo phototoxicity test. Genotoxic potential of LQFM048 was also analyzed by cytokinesis-block micronucleus assay (MNvit test-cytoB) in HepG2 cells. Our results showed that LQFM048 did not induce eye irritation and it was classified as UN GHS No Category for both STE and BCOP assays and non-irritating for HET-CAM test. LQFM048 showed non-potential skin sensitization with stimulation index (SI=0.7) in the LLNA:BrdU-ELISA method. Corroborating in vivo tests, it did not promote significant cytotoxicity in HaCaT cells and it showed similar levels of IL-18 when compared to control. Furthermore, LQFM048 induced non-phototoxic potential with photo-irritation factor (PIF) and mean photo effect (MPE) of 1 and -0.138, respectively, for 3T3 cells. Similarly, it was not phototoxic for in vivo testing with or without exposure to UVA, showing SI values of 1 and 1.2, respectively. The micronucleus test showed that LQFM048 was not genotoxic, under the conditions tested.In conclusion, LQFM048, a heterocyclic compound obtained through an environmentally acceptable simple synthetic route, seems to be safe for human use, especially for the development of a new sunscreen product, since it is neither an eye irritant, nor a contact allergen, nor mutagenic and nor phototoxic. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Oizumi, Takuya; Laakso, Ilkka; Hirata, Akimasa; Fujiwara, Osamu; Watanabe, Soichi; Taki, Masao; Kojima, Masami; Sasaki, Hiroshi; Sasaki, Kazuyuki
2013-07-01
The eye is said to be one of the most sensitive organs to microwave heating. According to previous studies, the possibility of microwave-induced cataract formation has been experimentally investigated in rabbit and monkey eyes, but not for the human eye due to ethical reasons. In the present study, the temperature elevation in the lens, the skin around the eye and the core temperature of numerical human and rabbit models for far-field and near-field exposures at 2.45 GHz are investigated. The temperature elevations in the human and rabbit models were compared with the threshold temperatures for inducing cataracts, thermal pain in the skin and reversible health effects such as heat exhaustion or heat stroke. For plane-wave exposure, the core temperature elevation is shown to be essential both in the human and in the rabbit models as suggested in the international guidelines and standards. For localised exposure of the human eye, the temperature elevation of the skin was essential, and the lens temperature did not reach its threshold for thermal pain. On the other hand, the lens temperature elevation was found to be dominant for the rabbit eye.
Safety and efficacy of personal care products containing colloidal oatmeal.
Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane
2012-01-01
Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period.
Safety and efficacy of personal care products containing colloidal oatmeal
Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane
2012-01-01
Background Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. Methods In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. Results We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Conclusion Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period. PMID:23204849
Robinson, June K; Friedewald, John J; Desai, Amishi; Gordon, Elisa J
2016-01-01
Perception of skin cancer risk, belief that sun protection prevents skin cancer, and having sun protection choices enhance sun protection behaviors by kidney transplant recipients, who are at greater risk of developing skin cancer than the general population. A randomized controlled trial used stratified recruitment of non-Hispanic White, non-Hispanic Black, and Hispanic/Latino kidney transplant recipients, who received a transplant 2-24 months prior to the study. The same culturally sensitive SunProtect™ program was delivered to all recipients with tablet personal computers in two urban ambulatory offices. Text messages reminders were provided at two week intervals. Self-reported surveys and skin pigmentation measured prior to the intervention and six weeks later were analyzed. Among 552 eligible participants, 170 participated (62 non-Hispanic Whites, 60Blacks, and 48 Hispanics). Among participants receiving the intervention with skin that burns after sun exposure and becomes tan or becomes irritated and gets darker, there was a statistically significant increase in self-reported knowledge, recognition of personal skin cancer risk, confidence in sun protection preventing skin cancer, and sun protection behaviors in participants compared to those receiving usual education (p<0.05). At the six week follow-up, participants in the intervention group with skin that burns or becomes irritated, had significantly less darkening of the sun-exposed forearm than control participants (p<0.05). Providing sun protection education with SunProtect™ in the springwith reminders during the summer facilitated adoption of sun protection behaviors among kidney transplant recipients with skin that burns or becomes irritated.
Robinson, June K.; Friedewald, John J.; Desai, Amishi; Gordon, Elisa J.
2016-01-01
Background Perception of skin cancer risk, belief that sun protection prevents skin cancer, and having sun protection choices enhance sun protection behaviors by kidney transplant recipients, who are at greater risk of developing skin cancer than the general population. Methods A randomized controlled trial used stratified recruitment of non-Hispanic white, non-Hispanic black, and Hispanic/Latino kidney transplant recipients, who received a transplant 2 to 24 months before the study. The same culturally sensitive SunProtect program was delivered to all recipients with tablet personal computers in 2 urban ambulatory offices. Text messages reminders were provided at 2-week intervals. Self-reported surveys and skin pigmentation measured before the intervention and 6 weeks later were analyzed. Results Among 552 eligible participants, 170 participated (62 non-Hispanic whites, 60 blacks, and 48 Hispanics). Among participants receiving the intervention with skin that burns after sun exposure and becomes tan or becomes irritated and gets darker, there was a statistically significant increase in self-reported knowledge, recognition of personal skin cancer risk, confidence in sun protection preventing skin cancer, and sun protection behaviors in participants compared with those receiving usual education (P < 0.05). At the 6-week follow-up, participants in the intervention group with skin that burns or becomes irritated had significantly less darkening of the sun-exposed forearm than control participants (P < 0.05). Conclusions Providing sun protection education with SunProtect in the spring with reminders during the summer facilitated adoption of sun protection behaviors among kidney transplant recipients with skin that burns or becomes irritated. PMID:26900599
... Headache Staggering Tremors Unconsciousness Weakness SKIN Bluish skin color Burns Irritation STOMACH AND INTESTINES Blood in the stool Burns of the food pipe (esophagus) Severe abdominal pain Vomiting Vomiting blood
... Rapid heartbeat NERVOUS SYSTEM Burning sensations Convulsions Dizziness Loss of alertness Memory problems Nervousness Numbness in arms and legs SKIN Burns Irritation Necrosis (holes) in the skin or underlying tissues
Jordan, Laura
2016-11-01
Occupational irritant contact dermatitis (OICD) is a dif cult and hard to manage condition. It occurs more frequently in certain occupations where contact with harsh chemicals, use of alcohol-based disinfectants, and frequent hand washing heightens the risk. Treatment for OICD includes patient education in addition to physical, topical, and systemic therapies. To review the pathogenesis and treatment options for OICD and evaluate the ef cacy of a selective skin-care regimen involv- ing a hand protectant cream alone as well as combined with a repair cream and speci c cleanser. A single-center open study was performed comprising 42 healthy male and female adult volunteers prone to occupational irritant contact dermatitis due to frequent wet work or contact with detergents. Between day 0 and day 7, subjects applied a hand protectant cream as needed on both hands (at least twice daily). On days 7 to 14, subjects applied a hand protectant cream and cleanser as needed on both hands (at least twice daily) as well as a repair cream each evening. A diary log was given to each volunteer for application control and for a subjective evaluation of daily tolerability. In these subjects prone to occupational irritant contact dermatitis, the hand protectant cream applied during the initial 7-day period was effective in restoring the damaged skin barrier and improving the stratum corneum hydration. A regimen that combined the hand protectant and repair creams with a speci c cleanser during a further 7-day period allowed contin- ued improvement of skin hydration and additional clinical bene ts while respecting the skin barrier function. The results of this study support the use of a 3-step approach for patients who are at risk of repeated exposure to external irritants. J Drugs Dermatol. 2016;15(suppl 11):s81-85..
Ishii, Aiko; Ogawa, Bunichiro; Koyama, Tomoko; Nakanishi, Yutaka; Sasaki, Minoru
2017-01-01
When conducting vaginal irritation studies, ovariectomized rats or rabbits are typically used according to practical reports. In the present study, we evaluated the influence of the estrus cycle in a vaginal irritation study using intact rats and ovariectomized rats, which exhibit a late diestrus-like condition, to determine whether intact rats can be useful for evaluating vaginal irritancy. Rats were divided into 4 groups: proestrus, estrus, and metestrus or diestrus in intact rats and ovariectomized rats. All the rats in each group were treated with a vehicle or sodium dodecyl sulfate, as the irritant, in single-dose and 4-day repeat-dose vaginal irritation studies. Each rat’s vagina was examined histopathologically, and the irritation score was calculated using a semiquantitative scoring system. In the single-dose study, the irritation scores for the proestrus or ovariectomized groups treated with sodium dodecyl sulfate were higher than those of the estrus group or metestrus or diestrus group. In the 4-day repeat-dose study, a significant histopathological difference was not found among the intact rats (proestrus, estrus, and metestrus or diestrus groups), and the irritation score range of the intact rats was similar to that of the ovariectomized rats, though the mean score of the intact rats was slightly lower than that of the ovariectomized rats. These results suggest that intact rats might be well suited for 4-day vaginal irritation studies and useful for evaluating vaginal irritancy using not only the mean score, but also individual irritation score ranges, whereas the estrus cycle would need to be identified in single-dose vaginal irritation studies. PMID:28458454
Marangoni, R A; Antunes, E; Brain, S D; de Nucci, G
1993-06-01
1. The purpose of the present study was to investigate the mechanisms by which venom from Phoneutria nigriventer spider induces increases in vascular permeability in rabbit skin. 2. Local oedema formation, in response to intradermally-injected agents, was measured in male New Zealand white rabbits as the local accumulation of i.v. injected 125I-labelled human serum albumin into skin sites. 3. Phoneutria nigriventer venom (10-30 micrograms/site) increased vascular permeability, which was inhibited by trasylol (10 micrograms/site) and the bradykinin B2 receptor antagonists D-Arg,[Hyp3,Thi5,8,D-Phe7]-BK (3 nmol/site) and Hoe 140 (0.3 nmol/site). In addition, the oedema induced by the venom was potentiated by the kinase II inhibitor, captopril (1 nmol/site). The lipoxygenase inhibitor, BWA4C (10 nmol/site) and the PAF antagonist, WEB 2086 (100 nmol/site) had no effect on the venom-induced increase in vascular permeability. 4. Incubation of rabbit plasma with Phoneutria nigriventer venom in vitro did not cause bradykinin formation. Further, the plasma kallikrein inhibitor, soybean trypsin inhibitor (10 micrograms/site), had no effect on the venom-induced increase in vascular permeability in rabbit skin. 5. These results indicate that the oedema produced by Phoneutria nigriventer venom is dependent on the activation of the tissue kallikrein-kinin system.
Marangoni, R. A.; Antunes, E.; Brain, S. D.; de Nucci, G.
1993-01-01
1. The purpose of the present study was to investigate the mechanisms by which venom from Phoneutria nigriventer spider induces increases in vascular permeability in rabbit skin. 2. Local oedema formation, in response to intradermally-injected agents, was measured in male New Zealand white rabbits as the local accumulation of i.v. injected 125I-labelled human serum albumin into skin sites. 3. Phoneutria nigriventer venom (10-30 micrograms/site) increased vascular permeability, which was inhibited by trasylol (10 micrograms/site) and the bradykinin B2 receptor antagonists D-Arg,[Hyp3,Thi5,8,D-Phe7]-BK (3 nmol/site) and Hoe 140 (0.3 nmol/site). In addition, the oedema induced by the venom was potentiated by the kinase II inhibitor, captopril (1 nmol/site). The lipoxygenase inhibitor, BWA4C (10 nmol/site) and the PAF antagonist, WEB 2086 (100 nmol/site) had no effect on the venom-induced increase in vascular permeability. 4. Incubation of rabbit plasma with Phoneutria nigriventer venom in vitro did not cause bradykinin formation. Further, the plasma kallikrein inhibitor, soybean trypsin inhibitor (10 micrograms/site), had no effect on the venom-induced increase in vascular permeability in rabbit skin. 5. These results indicate that the oedema produced by Phoneutria nigriventer venom is dependent on the activation of the tissue kallikrein-kinin system. PMID:8395291
2013-04-24
established to minimize the potential of dermal irritation and dermatitis (6). Chromium exposure can lead to allergic contact dermatitis , irritant... dermatitis with skin contact . (5; 15; 25; 33; 47). Nickel is potentially the most common contact allergen among the general population. Some studies...thresholds - a review focusing on occluded nickel exposure. Contact Dermatitis 52:57-64 21. Fogh CL, Andersson KG. 2000. Modelling of skin exposure
Draelos, Zoe D; Fowler, Joseph; Larsen, Walter G; Hornby, Sidney; Walters, Russel M; Appa, Yohini
2015-10-01
Although mild, fragrance-free, nonfoaming cleansers generally are recommended for individuals with sensitive skin, many consumers choose fragranced foaming cleansers. The addition of hydrophobically modified polymers (HMPs) to mild facial cleansers has been shown to improve product tolerability in individuals with sensitive skin while facilitating foaming. The objective of the 2 studies reported here was to assess the tolerability of a mild, HMP-containing, foaming facial cleanser with a fragrance that was free of common allergens and irritating essential oils in patients with sensitive skin. In the first study, 8 participants with clinically diagnosed fragrance sensitivity used a gentle foaming HMP-containing facial cleanser with or without fragrance for 3 weeks. Both cleansers improved global disease severity, irritation, and erythema with similar cleansing effectiveness. The second study was a 3-week, prospective, double-blind, randomized, 2-center study of 153 participants with clinically diagnosed sensitive skin. In this study, the fragranced gentle foaming cleanser with HMP was as well tolerated as a benchmark gentle, fragrance-free, nonfoaming cleanser. Itching, irritation, and desquamation were most improved from baseline in both groups. The participant-rated effectiveness of the cleanser with HMP was similar or better than the benchmark cleanser after 3 weeks of use. In conclusion, the gentle facial cleanser with HMPs and a fragrance offers a new option for adults with sensitive skin who may prefer, and commonly use, a fragranced and foaming product.
Enzymes, detergents and skin: facts and fantasies.
Basketter, D A; English, J S C; Wakelin, S H; White, I R
2008-06-01
In their raw state, enzymes of bacterial/fungal origin cause allergic reactions in the lung. Proteolytic enzymes also cause irritation to skin, eyes and the respiratory tract. For 40 years, encapsulated enzymes have been used worldwide in detergent products, especially laundry formulations, and have increasing importance due to biodegradability and functionality at low temperatures, offering environmental benefits. Uniquely to the U.K., for years it has been suggested that the inclusion of enzymes in such products leads to adverse skin reactions, including erythema, pruritus and exacerbation of eczema. In this review, we look at the facts, asking whether there is evidence that the hazards identified for enzymes translate into any risk for consumer health. By considering the actual exposures in consumer use and exaggerated product usage, it is concluded that the irritating and allergenic hazards of enzyme raw materials do not translate into a risk of skin reactions, either irritant or allergic. Investigations of numerous individuals with skin complaints attributed to laundry products demonstrate convincingly that enzymes were not responsible. Indeed, enzyme-containing laundry products have an extensive history of safe use. Thus, the supposed adverse effects of enzymes on skin seem to be a consequence of a mythology. The important practical lesson is that when primary or secondary care practitioners are presented with a skin complaint, it should not be dismissed as a result of using an enzyme-containing laundry product as the diagnosis will certainly lie elsewhere. Education for healthcare professionals could usefully be enhanced to take this on board.
In vitro and in vivo topical delivery studies of tretinoin-loaded ultradeformable vesicles.
Ascenso, Andreia; Salgado, Ana; Euletério, Carla; Praça, Fabíola Garcia; Bentley, Maria Vitória Lopes Badra; Marques, Helena C; Oliveira, Helena; Santos, Conceição; Simões, Sandra
2014-09-01
Ultradeformable vesicles are highly promising tools to enhance the percutaneous transport of different drugs such as tretinoin across the skin barrier and also to increase the formulation stability at absorption site and reduce the drug induced irritation. Topical delivery of tretinoin-loaded ultradeformable vesicles (tretinoin-UDV) was evaluated concerning different studies, such as: the release and permeation profiles (tape stripping); skin penetration (fluorescence analysis); induced electrical changes in skin barrier properties; cytotoxicity (Trypan Blue assay) and skin irritation in in vivo conditions (Draize test). The novel formulation performance was also compared to a commercial tretinoin formulation regarding in vivo studies. It was obtained a sustained and controlled drug release, as expected for UDV formulation. In addition, a dermal delivery was observed regarding the permeation study since it was not detected any drug amount in the receptor phase after 24h. Nile Red-UDV stained intensively mostly in the stratum corneum, corroborating the tape stripping results. Tretinoin-UDV decreased skin resistance, suggesting its ability to induce skin barrier disruption. Finally, the formulation vehicle (empty UDV) and tretinoin-UDV were not toxic under in vitro and in vivo conditions, at least, at 5×10(-3)mg/mL and 0.5mg/mL of tretinoin, respectively. Tretinoin-UDV is a promising delivery system for tretinoin dermal delivery without promoting skin irritation (unlike other commercial formulations), which is quite advantageous for therapeutic purpose. Copyright © 2014 Elsevier B.V. All rights reserved.
Ahad, Abdul; Aqil, Mohd; Kohli, Kanchan; Sultana, Yasmin; Mujeeb, Mohd
2016-09-01
The present study traces the development and characterization of the gel formulation of valsartan-loaded ultradeformable vesicles for management of hypertension. The prepared gel formulation of ultradeformable vesicles was evaluated for in vitro skin permeation, release kinetics, skin irritation, pharmacokinetics, and stability. The in vitro skin permeation study showed that the gel formulation of ultradeformable vesicles presented a flux value of 368.74 μg/cm(2)/h, in comparison to that of the traditional liposomal gel formulation, with an enhancement ratio of 26.91, through rat skin. The data for release kinetics showed that the release profile followed zero-order kinetics, and that the drug release mechanism was non-Fickian. The results of the skin irritation study demonstrated that the prepared formulation was safe, less irritant, and well-tolerated for transdermal delivery. The results of the pharmacokinetic study demonstrated that the AUC value of valsartan after transdermal administration was apparently increased. The formulation stored under a refrigerated condition showed greater stability, and results were found to be within the specification under storage conditions. It is evident from this study that the gel formulation of ultradeformable vesicles of valsartan is a promising delivery system for lipophilic drugs, and has reasonably good stability characteristics.
Lee, Sang S; Hong, Dong K; Jeong, Nam J; Lee, Jeung H; Choi, Yun-Seok; Lee, Ai-Young; Lee, Cheol-Heon; Kim, Kea J; Park, Hae Y; Yang, Jun-Mo; Lee, Ga-Young; Lee, Joon; Eun, Hee C; Moon, Kee-Chan; Seo, Seong J; Hong, Chang K; Lee, Sang W; Choi, Hae Y; Lee, Jun Y
2012-08-01
As many new cosmetic products are introduced into the market, attention must be given to contact dermatitis, which is commonly caused by cosmetics. We investigate the prevalence of preservative allergy in 584 patients with suspected cosmetic contact dermatitis at 11 different hospitals. From January 2010 to March 2011, 584 patients at 11 hospital dermatology departments presented with cosmetic contact dermatitis symptoms. These patients were patch-tested for preservative allergens. An irritancy patch test performed on 30 control subjects using allergens of various concentrations showed high irritancy rates. Preservative hypersensitivity was detected in 41.1% of patients. Allergens with the highest positive test rates were benzalkonium chloride (12.1%), thimerosal (9.9%) and methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) (5.5%). Benzalkonium chloride and chlorphenesin had the highest irritancy rate based on an irritancy patch test performed using various concentrations. Seven of 30 normal subjects had a positive irritant patch reading with 0.1% benzalkonium chloride and eight of 30 normal subjects had a positive irritant patch reading at 4 days with 0.5% chlorphenesin in petrolatum. Although benzalkonium chloride was highly positive for skin reactions in our study, most reactions were probably irritation. MCI/MI and thimerosal showed highly positive allergy reactions in our study. The optimum concentration of chlorphenesin to avoid skin reactions is less than 0.5%. © 2012 Japanese Dermatological Association.
Primary Ocular Irritation Potential of Ball Powder (Trade Name) in Male Rabbits
1989-07-01
rugae , congestion, swelling, moderate circumiridial hyperemia or injection, any of these or any combination thereof, iris still reacting to iight...inflammation of the iris (other than a slight deepening of the rugae or a slight hyperemia of the circumcorneal blood vessels); an obvious swelling in the
Prevalence of fur mites in pet rabbits in South Korea.
Kim, Sang-Hun; Jun, Hyung-Kyou; Song, Kun-Ho; Gram, Dunbar; Kim, Duck-Hwan
2008-06-01
The prevalence of fur mites, Cheyletiella parasitovorax and Leporacarus gibbus, in pet rabbits in South Korea was investigated by a diagnostic evaluation of skin surface tape strips and hair coat combings. C. parasitovorax was found in 80 of 140 rabbits (57.1%) and L. gibbus in six of 140 rabbits (4.3%). Clinical signs of pruritus and scaling were observed in 17 of 80 and 76 of 80 infested rabbits, respectively.
Sallam, Marwa Ahmed; Marín Boscá, María Teresa
2017-10-01
This work aimed at the development of a biocompatible, non-oily nanomedicine for follicular delivery of adapalene (AD) ameliorating its irritation potential for convenient localized topical treatment of acne vulgaris. AD was efficiently incorporated into poly-ε-caprolactone nanospheres (NS) with an encapsulation efficiency of 84.73% ± 1.52%, a particle size of 107.5 ± 8.19 nm, and zeta potential of -13.1 mV demonstrating a sustained-release behavior. The AD-NS were embedded in either hydroxypropyl methylcellulose (HPMC) or hyaluronate (HA) gel. The ex vivo human skin dermatokinetics of AD from each system was studied. The nanoparticles dispersion showed significantly higher AD retention in the epidermis and dermis than AD suspension. NS-HPMC decreased whereas NS-HA increased AD retained in all the skin layers. The fate of the NS and the role of the hydrogel in modulating skin distribution was evaluated by confocal laser scanning microscopy (CLSM) imaging of fluorescently labeled NS. CLSM illustrated follicular localization of the florescent NS. HPMC gel restricted the presence of NS to the stratum corneum and epidermis. HA gel enhanced the penetration of NS to all the skin layers. In vitro skin irritation using human dermal fibroblasts and in vivo animal tolerability studies were performed. Accordingly, HA gel-dispersed AD-NS presented a nonirritant compromised cosmeceutical formulation suitable for oily acneic skin. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Ahad, Abdul; Aqil, Mohd; Kohli, Kanchan; Sultana, Yasmin; Mujeeb, Mohd
2016-05-01
Nanoethosomal carriers of valsartan have been previously prepared, characterized and optimized. A gel formulation of valsartan vesicular lipid carriers was composed of Carbopol(®) (1% w/w), polyethylene glycol-400 (15% w/w) and triethanolamine (0.5% w/w). The influence of the valsartan nanoethosomal formulation developed on the blood pressure of experimental hypertensive rats, and its potential for skin irritation, are presented in this report. The experimental rats were divided into three groups; the control group received no treatment (Group A). Group B was administered methyl prednisolone acetate (20 mg/kg/week) for two weeks (hypertensive control). Group C received methyl prednisolone acetate, followed by administration of the valsartan ethosomal formulation. The blood pressure of the rats was measured using a non-invasive rat blood pressure instrument based on the tail-cuff technique. The statistical analysis was performed using GraphPad InStat 3 software. The treatment group showed a significant (P < 0.05) and constant fall in blood pressure, for up to 48 h. The valsartan ethosomal formulation was found to be effective, with a 34.11% reduction in blood pressure. The formulation's potential for skin irritation was assessed by the Draize irritation score test, which ruled out the possibility of any skin irritation caused by application of the formulation in rats. Our results suggest that nanoethosomes are efficient carriers for transdermal delivery of valsartan, for the management of hypertension.
Corazza, Monica; Lauriola, Maria Michela; Bianchi, Anna; Zappaterra, Mario; Virgili, Annarosa
2010-01-01
Irritation from surfactants contained in detergents is a frequent adverse reaction to cosmetics. Sensitization to surfactants is also possible. In the literature, comparative studies about irritant and sensitizing potential of different surfactants are heterogeneous and inconclusive about the best molecules to use. We compared the irritant and sensitizing potential of some surfactants that are usual components in marketed synthetic detergents (syndets) to obtain practical information regarding commonly used detergents. We patch-tested eight surfactants of the different types (anionic, cationic, amphoteric, and non-ionic) in 105 patients. Assessment of allergic reactions of tested surfactants was carried out in accordance with the recommendations of the International Contact Dermatitis Research Group; assessment of irritant power followed the amended Draize classification. None of the eight surfactants in our series gave positive allergic reactions. Only cocamidopropyl betaine from the Italian standard (Società Italiana di Dermatologia Allergologica, Professionale e Ambientale [SIDAPA]) series gave five positive reactions among 105 patients. None of the eight studied surfactants induced skin irritation. The most tolerated are two new mild anionics (sodium cocoyl glutamate and sodium lauroyl oat amino acids) and an amphoteric agent (disodium cocoamphodiacetate). From this study, we deduce that cosmetic companies' efforts to search for and market new products with very mild surfactants have been generally successful.
... tongue STOMACH AND INTESTINES Blood in the stool Burns in the food pipe (esophagus) Severe abdominal pain ... decreased level of consciousness) Walking difficulties SKIN Irritation Burns Holes in the skin or tissues under the ...
Challenges and opportunities in dermal/transdermal delivery
Paudel, Kalpana S; Milewski, Mikolaj; Swadley, Courtney L; Brogden, Nicole K; Ghosh, Priyanka; Stinchcomb, Audra L
2010-01-01
Transdermal drug delivery is an exciting and challenging area. There are numerous transdermal delivery systems currently available on the market. However, the transdermal market still remains limited to a narrow range of drugs. Further advances in transdermal delivery depend on the ability to overcome the challenges faced regarding the permeation and skin irritation of the drug molecules. Emergence of novel techniques for skin permeation enhancement and development of methods to lessen skin irritation would widen the transdermal market for hydrophilic compounds, macromolecules and conventional drugs for new therapeutic indications. As evident from the ongoing clinical trials of a wide variety of drugs for various clinical conditions, there is a great future for transdermal delivery of drugs. PMID:21132122
Nisbet, Stephanie
Data were generated from three studies to assess the tolerability and acceptability of a prototype cosmetic lip balm. Dermatological assessments of topical compatibility (primary and cumulative irritability and sensitization), photoirritant and topical photosensitizer potential, and acceptability for safe use of a prototype cosmetic lip balm on sensitive skin are summarized. In Study 1, the product was applied to the volunteers' backs under a semiocclusive patch followed by patch removal/reapplication over 6 weeks to assess the irritant and allergic potential of the product. Dermatological assessments were performed at the beginning and end of the study or when there was evidence of positivity or adverse event. Study 2 was conducted by applying the product to the volunteers' backs under a semiocclusive patch, followed by patch removal/reapplication and irradiation of the test area with ultraviolet A (UVA) radiation at various intervals over 5 weeks. Dermatological assessments were performed to assess the product's role in the induction of photoirritancy and photosensitization. Clinical and subjective assessments for acceptability were obtained during Study 3 in volunteers with a diagnosis of sensitive skin and those who used the product as per instructions for use during the study period. The data generated from the three studies demonstrated no evidence of primary or cumulative dermal irritation or of dermal sensitization. In addition, no photoirritation potential or photosensitization potential was observed. As assessed by dermatologic monitoring and subject diary entries, the prototype lip balm did not cause irritation or sensitization reactions when used for 28 days in volunteers with a diagnosis of sensitive skin. Based on these findings, the prototype lip balm can be considered suitable for use for people with sensitive skin.
Contact Eczema Caused by True Teak (Tectona Grandis)
Krogh, H. K.
1962-01-01
An epidemiological study of occupational contact eczema in a furniture factory is presented. The localization, distribution, and clinical features of the skin lesions were characteristic of contact eczema caused by a sensitizing or irritating dust. True teak—Tectona grandis—was the cause of the skin condition. That teak is a fairly potent sensitizer and also contains primary irritants is fully confirmed by the present study. About half the employees who were heavily exposed to teak dust suffered from eczema and/or severe itching. Only 8% of those with slight exposure to teak dust experienced skin symptoms. Patch tests with native teak dust moistened with water were applied on 10 “controls” and 112 workers who were exposed to teak in various working procedures. Moistened teak dust produced toxic reactions in 20·5%, while native teak dust did not have primary irritant effects and was, therefore, considered to be the substance of choice for patch testing; 18·7% of the workers showed an allergic skin reaction to native teak dust. The diagnosis of allergic contact eczema was made in 12·5%, and 6·2% were considered to have latent allergy. Primary irritant (contact) eczema was considered to be present in four individuals who had experienced acute, transitory, eczematous eruptions during the hot part of the summer when they perspired freely. In these cases the patch test to native teak dust was negative. Desensitization or “hardening” was observed in four workers. In most cases the skin lesions were not severe enough to cause sickness absence. The cause of the relatively high percentage of sensitization to teak among the workers in the factory is discussed. The importance of suitable prophylactic measures is stressed. PMID:14459786
Control of Bovicola Equi (Phthiraptera: Trichodectidae) with Dimilin and Permethrin
USDA-ARS?s Scientific Manuscript database
Lice are wingless ectoparasitic insects that can irritate and injure their hosts and transmit pathogens. Horses and ponies can be infested with a chewing louse, Bovicola equi (Denny) (Phthiraptera: Trichodectidae) that irritates the animals, creates skin lesions, causes hair loss, and generally redu...
Leggat, Peter A; Smith, Derek R
2006-01-01
Dermatitis is a common problem both in the workplace and in the general community. Airline personnel represent a novel occupational group as they are also exposed to a wide range of potential chemical irritants and other aggravating factors, such as low relative humidity and airborne pollutants. Common skin irritants include dielectric fluids from electrodischarge machining, 'prepreg' materials and sealants in aircraft manufacture, kerosene and various jet-fuel components. Commercial jet fuel is a complex mixture of aliphatic and aromatic compounds, and there is potential for dermal exposure among refueling and maintenance crew. Low relative humidity appears to exacerbate dermatitis amongst aircrew, especially on longer flight durations. Pilots may also be exposed to additional skin irritants outside of the cabin environment, such as ethylene glycol, hydraulic fluid or jet fuel, all of which may be encountered during routine inspections of aircraft before and after flight. Given these factors, preventive measures must carefully consider the undoubted potential for contact with irritants and allergens, which may lead to dermatitis in airline personnel.
Dermal safety assessment of Arm & Hammer laundry products formulated for sensitive skin.
Frederick, Douglas M; Vorwerk, Linda; Gupta, Archana; Ghassemi, Annahita
2017-09-01
The prevalence of sensitive skin among the general population in industrialized countries is reported to be over 50%. Sensitive skin subjects often report significant reactions to contact with cosmetics, soaps and other consumer products. This paper describes the overall skin compatibility and mildness program for a newly developed, lightly fragranced, colorant free laundry product (i.e. Arm & Hammer™ Sensitive Skin plus Skin-Friendly Fresh Scent), specially formulated for individuals with sensitive skin. The skin mildness of the product was compared to Arm & Hammer™ Free & Clear liquid laundry detergent with no fragrance or colorant, and an established history of safe use by sensitive skin consumers. The test material was a liquid laundry product with a light scent formulated for sensitive skin consumers (Arm & Hammer™ Sensitive Skin plus Skin-Friendly Fresh Scent). The product was compared to commercially marketed products for sensitive skin with a history of skin safety in the marketplace, including: a very similar product formulation (Arm & Hammer™ Free & Clear with no fragrance), and several selected competitors' products. Studies were conducted among individuals with self-assessed sensitive skin (based on a questionnaire) using standard protocols for the Human Repeat Insult Patch Test (HRIPT), 10-Day Cumulative Irritation, the Wrist Band Wear test, and the Safety In-Use testing. Responses in all protocols were evaluated by visual scoring of potential dermatologic reactions, and recording any sensory effects at the time of the examination. In addition, sensory effects collected from panelists' daily diaries were also evaluated. The HRIPT confirmed that neither the fragrance alone, nor the product formulation with fragrance, induced contact sensitization in sensitive skin subjects. The 10-Day cumulative irritation study conducted using sensitive skin subjects showed highly favorable skin compatibility, and the test product was comparable to the control product (Arm & Hammer Free & Clear) and other nonirritant controls. In the Wrist Band Wear test, exposure to laundered fabrics under exaggerated conditions gave similar results for the test and control products, with no objective signs of skin irritation, and no self-reported persistent adverse sensory effects. Very mild, transient and isolated sensory effects were noted in daily diaries by a small proportion of subjects, and were similar for the test and control products. The Safety In-Use tests evaluated 4-week exposure to product and laundered fabrics under realistic use conditions. There were no clinically objective signs of skin irritation, and reports of transitory, mild sensory effects were minimal and similar for the test and controls. A comprehensive skin safety program on a lightly scented sensitive skin laundry formulation (i.e. Arm & Hammer™ Sensitive Skin plus Skin-Friendly Fresh Scent) conducted among panels of self-assessed sensitive skin subjects demonstrated that the presence of a light fragrance did not adversely impact skin compatibility in any of the testing protocols when the product was compared to a similar product with no fragrance. The lightly fragranced product demonstrated overall skin compatibility and mildness when tested in a self-assessed sensitive skin population, and compared favorably to currently marketed sensitive skin products.
... oil without problems, but some people may develop contact dermatitis (an allergic skin rash) or skin irritation on ... References Jack AR, Norris PL, Storrs FJ. Allergic contact dermatitis to plant extracts in cosmetics . Seminars in Cutaneous ...
Ballantyne, B; Jordan, S L
2001-01-01
Aqueous solutions of > or =5% glutaraldehyde (GA) are of moderate acute peroral toxicity and those of < or =2% are of slight toxicity. By single sustained skin contact, aqueous GA solutions of > or =45% are of moderate acute percutaneous toxicity, those of 25% are of slight toxicity and those of =15% do not present an acute percutaneous hazard. Vapor generated at ambient temperature may cause sensory irritant effects to the eye and respiratory tract, but not acute respiratory tract injury. The 50% decrease in respiratory rate (rd(50)) is 13.86 ppm. A 0.1% solution of GA is not irritating to the eye; the threshold for conjunctival irritation is 0.2% and for corneal injury it is 1.0%. Eye injury is moderate at 2% and severe at > or =5%. Primary skin irritation depends on the duration and contact site, occlusion and solvent. By sustained contact, the threshold for skin irritation is 1%, above which erythema and edema are dose related. With 45% and higher, skin corrosion may occur. There is a low incidence of skin sensitizing reactions, with an eliciting threshold of 0.5% aqueous GA. However, GA is neither phototoxic nor photosensitizing. Subchronic repeated exposure studies by the peroral route show only renal physiological compensatory effects, secondary to reduced water consumption. Repeated skin contact shows only minor skin irritant effects without systemic toxicity. By subchronic vapor exposure, effects are limited to the nasal mucosa at 1.0 ppm, with a no-effect concentration generally at 0.1 ppm. There is no evidence for systemic target organ or tissue toxicity by subchronic repeated exposure by any route. A chronic drinking water study showed an apparent increase, in females only, of large granular cell lymphocytic leukemia but this was not dosage related. This is most likely the result of a modifying effect on the factor(s) responsible for the expression of this commonly occurring rat neoplasm. A chronic (2-year) inhalation toxicity/oncogenicity study showed inflammatory changes in the anterior nasal cavity but no neoplasms or systemic toxicity. In vitro genotoxicity studies--bacterial mutagenicity, forward gene mutation (HGPRT and TK loci), sister chromatid exchange, chromosome aberration, UDS and DNA repair tests--have given variable results, ranging from no effect through to weak positive. In vivo genotoxicity studies--micronucleus, chromosome aberration, dominant lethal and Drosophila tests--generally have shown no activity but one mouse intraperitoneal study showed bone marrow cell chromosome aberrations. Developmental toxicity studies show GA not to be teratogenic, and a two-generation study showed no adverse reproductive effects. Percutaneous pharmacokinetic studies showed low skin penetration, with lowest values measured in vitro in rats and human skin. Overexposure of humans produces typical sensory irritant effects on the eye, skin and respiratory tract. Some reports have described an asthmatic-like reaction by overexposure to GA vapor. In most cases this resembles reactive airways dysfunction syndrome, and the role of immune mechanisms is uncertain. Local mucosal effects may occur if medical instruments or endoscopes are not adequately decontaminated. Protection of individuals from the potential adverse effects of GA exposure requires that there be adequate protection of the skin, eyes and respiratory tract. The airborne concentration of GA vapor should be kept below the recommended safe exposure level (e.g. the threshold limit value) by the use of engineering controls. Those who work with GA should, through a training program, be aware of the properties of GA, its potential adverse effects, how to handle the material safely and how to deal with accidental situations involving GA. If effects develop in exposed workers, the reasons should be determined immediately and corrective methods initiated. (c) 2001 John Wiley & Sons, Ltd.
1975-07-22
Mononitroglycerins Nitrocellulose White Phosphor 20. ABSTRACT (C^nllnu eery and Identify by block number) 0D | jSJ’TJ M73 EDITION OF I NOV 6» IS...White Phosphorus 2. Synthesis of DNGs and MNGs 3. Analysis of Chemicals . C. Acute LD D. Primary Skin and Eye Irritation E. Dermal...by the Radford Army Ammunition Plant (Radford, Virginia). 2. Synthesis of DNGs and MNGs a. 1,2-DNG: to that of Dunstan et al.— The sample was
Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro
2013-12-01
Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.
Cho, Sun-A; An, Susun; Lee, Eunyoung; Shin, Kyeho; Cho, Jun-Cheol; Lee, Tae Ryong
2012-07-20
Using a human corneal cell line (HCE-T cells) and 2 evaluation criteria, we developed a new alternative method to assess the eye irritation potential of chemicals. We exposed HCE-T cells to different concentrations of 38 chemicals for 1h and measured relative cell viability (RCV) as an endpoint at each concentration. Using the RCV values, we calculated the RCV50. We also exposed HCE-T cells to 3 fixed concentrations of the 38 chemicals (5%, 0.5%, and 0.05%) for 1h and measured the RCV at each concentration. Using the RCV values at 5%, 0.5%, and 0.05%, we developed a new criterion for eye irritation potential (total eye irritation score, TEIS) and estimated the ocular irritancy. We then assessed the correlation of the results of RCV50 and TEIS with those of the Draize rabbit eye irritation. Both the RCV50 and TEIS results exhibited good positive correlations (sensitivity: 80.77%, specificity: 83.33%, and accuracy: 81.58% for TEIS; sensitivity: 73.08-76.92%, specificity: 75.00%, and accuracy: 73.68-76.32% for RCV50). We conclude that the new in vitro model using HCE-T cells is a good alternative evaluation model for the prediction of the eye irritation potential of chemicals. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
... You may need additional treatment. What is contact dermatitis? Contact dermatitis is caused by irritation of the skin by ... Lichen simplex chronicus may be a result of contact dermatitis or other skin disorder that has been present ...
Current Treatments Available for Scleroderma Patients
... from infection from bacteria at the site of infusion, the most common include edema (swelling); accumulation of ... irritated skin and/or hardening of skin at infusion site; flushing, faintness, dizziness or lightheadedness. Less common ...
Late skin damage in rabbits and monkeys after exposure to particulate radiations
NASA Astrophysics Data System (ADS)
Bergtold, D. S.; Cox, A. B.; Lett, J. T.; Su, C. M.
Skin biopsies were taken from the central regions of the ears of New Zealand white rabbits following localized exposure of one ear of each rabbit to 530 MeV/amu Ar or 365 MeV/amu Ne ions. The unirradiated ears served as controls. Biopsies were taken also from the chests and inner thighs of rhesus monkeys after whole-body exposure to 32 MeV protons and from unirradiated control animals. The linear energy transfers (LET∞'s) for the radiations were 90 +/- 5, 35 +/- 3, and ~1.2 keV/μm, respectively. In the rabbit studies, explants were removed with a 2 mm diameter dermal punch at post-irradiation times up to five years after exposure. Similar volumes of monkey tissue were taken from skin samples excised surgically 16-18 years following proton irradiation. Fibroblast cultures were initiated from the explants and were propagated in vitro until terminal senescence (cessation of cell division) occurred. Cultures from irradiated tissue exhibited decreases in doubling potential that were dependent on radiation dose and LET∞ and seemed to reflect damage to stem cell populations. The implications of these results for astronauts exposed to heavy ions and/or protons in space include possible manifestations of residual effects in the skin many years after exposure (e.g. unsatisfactory responses to trauma or surgery).
NASA Astrophysics Data System (ADS)
Park, Yoon-Hee; Jeong, Sang Hoon; Yi, Sang Min; Hyeok Choi, Byeong; Kim, Yu-Ri; Kim, In-Kyoung; Kim, Meyoung-Kon; Son, Sang Wook
2011-07-01
The human skin equivalent model (HSEM) is well known as an attractive alternative model for evaluation of dermal toxicity. However, only limited data are available on the usefulness of an HSEM for nanotoxicity testing. This study was designed to investigate cutaneous toxicity of polystyrene and TiO2 nanoparticles using cultured keratinocytes, an HSEM, and an animal model. In addition, we also evaluated the skin sensitization potential of nanoparticles using a local lymph node assay with incorporation of BrdU. Findings from the present study indicate that polystyrene and TiO2 nanoparticles do not induce phototoxicity, acute cutaneous irritation, or skin sensitization. Results from evaluation of the HSEMs correspond well with those from animal models. Our findings suggest that the HSEM might be a useful alternative model for evaluation of dermal nanotoxicity.
Self-Assembled Cubic Liquid Crystalline Nanoparticles for Transdermal Delivery of Paeonol
Li, Jian-Chun; Zhu, Na; Zhu, Jin-Xiu; Zhang, Wen-Jing; Zhang, Hong-Min; Wang, Qing-Qing; Wu, Xiao-Xiang; Wang, Xiu; Zhang, Jin; Hao, Ji-Fu
2015-01-01
Background The aim of this study was to optimize the preparation method for self-assembled glyceryl monoolein-based cubosomes containing paeonol and to characterize the properties of this transdermal delivery system to improve the drug penetration ability in the skin. Material/Methods In this study, the cubic liquid crystalline nanoparticles loaded with paeonol were prepared by fragmentation of glyceryl monoolein (GMO)/poloxamer 407 bulk cubic gel by high-pressure homogenization. We evaluated the Zeta potential of these promising skin-targeting drug-delivery systems using the Malvern Zeta sizer examination, and various microscopies and differential scanning calorimetry were also used for property investigation. Stimulating studies were evaluated based on the skin irritation reaction score standard and the skin stimulus intensity evaluation standard for paeonol cubosomes when compared with commercial paeonol ointment. In vitro tests were performed on excised rat skins in an improved Franz diffusion apparatus. The amount of paeonol over time in the in vitro penetration and retention experiments both was determined quantitatively by HPLC. Results Stimulating studies were compared with the commercial ointment which indicated that the paeonol cubic liquid crystalline nanoparticles could reduce the irritation in the skin stimulating test. Thus, based on the attractive characteristics of the cubic crystal system of paeonol, we will further exploit the cosmetic features in the future studies. Conclusions The transdermal delivery system of paeonol with low-irritation based on the self-assembled cubic liquid crystalline nanoparticles prepared in this study might be a promising system of good tropical preparation for skin application. PMID:26517086
Primary Dermal Irritation Potential of Components of the M-258A-1 Decontamination Kit (Study 1).
1981-09-01
cells and lymphocytes with an occasional heterophil in the connective tissue sheaths of a few hair follicles deep in the dermis. DX: Folliculitis ...acute, diffuse, mild to moderate, dermis, skin. DX: Folliculitis , subacute, multifocal, minimal, hair follicles, skin. Slide 4 - Skin: The entire skin...the dermis. DX: Hyperplasia, diffuse, moderate, epidermis, skin. DX: Degeneration, subacute, diffuse, minimal to mild, dermis, skin. DX: Folliculitis
Arroyo-Acevedo, Jorge; Franco-Quino, Cesar; Ruiz-Ramirez, Eliberto; Chávez-Asmat, Roberto; Anampa-Guzmán, Andrea; Raéz-González, Ernesto; Cabanillas-Coral, José
2016-01-01
Introduction Allergies are a problem that greatly affects the population, and hence the use of antiallergic medications is fairly widespread. However, these drugs have many adverse effects. The use of medicinal plants could be an option, but they need to be evaluated. Objective This study was designed to evaluate the antiallergic effect of the atomized extract of rhizome of Curcuma longa, flowers of Cordia lutea, and leaves of Annona muricata. Materials and methods Twenty-four New Zealand white albino rabbits were randomized into 2 groups. Group A received the atomized extract diluted in physiological saline (APS) and group B received it diluted in Freund’s adjuvant (FA). Then, the back of each rabbit was divided into 4 quadrants. The A-I quadrant received only physiological saline. The A-I quadrants of each rabbit conformed the PS group. The following 3 quadrants received the APS in 10 μg/mL, 100 μg/mL, and 1,000 μg/mL, respectively. The B-I quadrant received only FA. The B-I quadrants of each rabbit conformed the FA group. The following 3 quadrants received the AFA in 10 μg/mL, 100 μg/mL, and 1,000 μg/mL, respectively. The occurrence of erythema and edema was recorded according to the Draize scoring system and the primary irritation index. After 72 hours, biopsies were performed. Results The AFA group presented significantly less erythema and edema compared to the FA group (P<0.05). The histopathologic evaluation at 72 hours showed normal characteristics in the APS group. Conclusion Considering the clinical and histopathological signs, we conclude that the administration of the atomized extract of rhizome of C. longa, flowers of C. lutea, and leaves of A. muricata lacks antigenic effect but could have an antiallergenic effect in a model of dermal irritation in rabbits. PMID:27877047
Arroyo-Acevedo, Jorge; Franco-Quino, Cesar; Ruiz-Ramirez, Eliberto; Chávez-Asmat, Roberto; Anampa-Guzmán, Andrea; Raéz-González, Ernesto; Cabanillas-Coral, José
2016-01-01
Allergies are a problem that greatly affects the population, and hence the use of antiallergic medications is fairly widespread. However, these drugs have many adverse effects. The use of medicinal plants could be an option, but they need to be evaluated. This study was designed to evaluate the antiallergic effect of the atomized extract of rhizome of Curcuma longa , flowers of Cordia lutea , and leaves of Annona muricata . Twenty-four New Zealand white albino rabbits were randomized into 2 groups. Group A received the atomized extract diluted in physiological saline (APS) and group B received it diluted in Freund's adjuvant (FA). Then, the back of each rabbit was divided into 4 quadrants. The A-I quadrant received only physiological saline. The A-I quadrants of each rabbit conformed the PS group. The following 3 quadrants received the APS in 10 μg/mL, 100 μg/mL, and 1,000 μg/mL, respectively. The B-I quadrant received only FA. The B-I quadrants of each rabbit conformed the FA group. The following 3 quadrants received the AFA in 10 μg/mL, 100 μg/mL, and 1,000 μg/mL, respectively. The occurrence of erythema and edema was recorded according to the Draize scoring system and the primary irritation index. After 72 hours, biopsies were performed. The AFA group presented significantly less erythema and edema compared to the FA group ( P <0.05). The histopathologic evaluation at 72 hours showed normal characteristics in the APS group. Considering the clinical and histopathological signs, we conclude that the administration of the atomized extract of rhizome of C. longa , flowers of C. lutea , and leaves of A. muricata lacks antigenic effect but could have an antiallergenic effect in a model of dermal irritation in rabbits.
Seddiek, Shaker A; Khater, Hanem F; El-Shorbagy, Mohamed M; Ali, Ali M
2013-06-01
Sarcoptes scabiei var. cuniculi is one of the most important veterinary ectoparasites in rabbits and results in considerable loss of weight, productivity, and wool quality. The acaricidal activity of aqueous leaf extract of neem (CAN) and ivermectin (IVR) were evaluated in vitro and in vivo against S. scabiei var. cuniculi. Rabbits were classified into four groups (ten rabbits each). The first group (group 1) was designated as the negative control group. Each rabbit of the other groups was experimentally infested with 50 mites. One month post-infestation, the second group (group 2) was not treated and taken into account as the positive control group. The third group (group 3) was subcutaneously injected with 1 % IVR (200 μg/kg body weight, three times within a week interval). The fourth group (group 4) was treated topically with CAN (25 %) every 3 days for three consecutive weeks. Index scoring of lesions was described weekly. The number of live mites (larvae, nymphs, and adults) on each rabbit was counted on the 14th, 28th, and 42th day post-treatment (PT). Blood samples were taken 28 and 42 days PT for estimation of some chemical parameters. The body weight and cumulative body weight gain were recoded 14, 28, and 42 days PT. CAN (40 %) was highly efficacious against larvae of S. scabiei var. cuniculi as 100 % mortality was reached 24 h PT. On the other hand, all treated mites with CAN (20 %) and IVR died 48 h PT. The lethal values of CAN (LC50, LC90, LC95, and LC99) were 7.496, 14.67, 17.75, and 25.37 %, respectively, 48 h PT. Lesion scoring in groups 3 and 4 were significantly decreased (P ≤ 0.05), reaching 0.20 and 0.40, respectively, when compared with that of group 2 (4.00), 42 days PT. Twenty-eight days PT, the reduction percentages of mites infesting rabbits were 93.38 and 93.09 % for IVR and CAN, respectively. However, complete mite reduction was reached 42 days PT. Rabbits treated with CAN did not show signs of restlessness or irritation, respiratory signs, or inflammation on the eye and/or skin at the time of application or afterwards. Regarding biochemical analysis, the levels of aspartate aminotransferase, alanine aminotransferase, creatinine, and total cholesterol in rabbits treated with CAN were decreased significantly (P ≤ 0.05) than those of rabbits of the positive control group and those treated with IVR. On the other hand, the levels of total protein, albumin, and globulin of rabbits in group 4 were significantly (P ≤ 0.05) increased when compared with the corresponding values of groups 2 and 3. The body weight and cumulative body weight gain of rabbits treated with CAN were significantly increased (P ≤ 0.05) when compared with such values of groups 2 and 3, 28 and 42 days PT. The present data indicated that CAN had in vitro and in vivo acaricidal efficiency similar to that of IVR and improved the performance of rabbits without inducing adverse effects on treated rabbits; consequently, CAN could be suitable as a promising alternative acaricide for veterinary use.
Evans, Richard L; Turner, Graham A; Bates, Susan; Robinson, Teresa; Arnold, David; Marriott, Robert E; Pudney, Paul D A; Bonnist, Eleanor Y M; Green, Darren
2017-11-01
The study objectives were to demonstrate that glycerol, when topically applied from a roll-on antiperspirant formulation, can be delivered directly to human skin ex vivo and the axillary stratum corneum (SC) in vivo, and to assess whether it improves the quality of the axillary skin barrier. Ex vivo human skin absorption of glycerol was measured following application of a roll-on antiperspirant formulation containing 4% 13 C 3 -glycerol. Skin distribution of 13 C 3 -glycerol over 24 h was assessed using gas chromatography-mass spectrometry. In vivo axillary SC penetration was measured by confocal Raman spectroscopy and multivariate curve-resolution software 1 h after topical application of a roll-on antiperspirant formulation containing 8% deuterated glycerol (d 5 -glycerol). A clinical study was conducted to determine the efficacy of a roll-on antiperspirant formulation containing 4% glycerol in reducing shaving-induced visual irritation and in increasing axillary-skin hydration. Ex vivo skin absorption studies indicated that the formulation delivered 13 C 3 -glycerol into the SC at all timepoints over the 24-h period. In vivo Raman measurements (1 h after application) demonstrated that d 5 -glycerol was detectable to a depth of at least 10 μm in the axillary SC. Application of 4% glycerol from a roll-on antiperspirant formulation to the axilla was associated with significantly less visible irritation and greater skin hydration than observed with the control (glycerol-free) product. These studies demonstrate that glycerol, incorporated in a roll-on antiperspirant formulation, is delivered directly and rapidly to all depths of the axillary SC, and results in improvements in visible irritation and hydration in the axilla.
Wind Turbines Make Waves: Why Some Residents near Wind Turbines Become Ill
ERIC Educational Resources Information Center
Havas, Magda; Colling, David
2011-01-01
People who live near wind turbines complain of symptoms that include some combination of the following: difficulty sleeping, fatigue, depression, irritability, aggressiveness, cognitive dysfunction, chest pain/pressure, headaches, joint pain, skin irritations, nausea, dizziness, tinnitus, and stress. These symptoms have been attributed to the…
21 CFR 346.50 - Labeling of anorectal drug products.
Code of Federal Regulations, 2011 CFR
2011-04-01
...., cream, lotion, or ointment).” (b) Indications. The labeling of the product states, under the heading... protective coating over inflamed tissues to help prevent drying of tissues.” (B) “Temporarily protects irritated areas.” (C) “Temporarily relieves burning.” (D) “Provides temporary relief from skin irritations...
Pittman, Joyce; Rawl, Susan M; Schmidt, C Max; Grant, Marcia; Ko, Clifford Y; Wendel, Christopher; Krouse, Robert S
2008-01-01
The purpose of this study is to describe demographic, clinical, and quality-of-life variables related to ostomy complications (skin irritation, leakage, and difficulty adjusting to an ostomy) in a veteran population in the United States. The original study employed a descriptive crosssectional study using a mixed method design. This secondary analysis used the quantitative data collected. Two hundred thirty-nine veterans with intestinal ostomies from 3 Veteran's Administration hospitals participated in the study. Instruments used for this investigation included the City of Hope Quality of Life: Ostomy Instrument. Demographic and medical history data were collected from the survey, the Veteran's Administration health information system, and the Tumor Registry database. A self-administered survey questionnaire (mCOH-QOL-Ostomy) was mailed to each participant. The severity of skin irritation, problems with leakage, and difficulty adjusting were significantly related to demographic, clinical, and quality-of-life domains. Univariate analyses showed that age, income, employment, preoperative care (stoma site marking and education), having a partner, ostomy type, reason for ostomy, time since surgery, total quality-of-life scores and scores on all 4 domains of quality of life were related to the severity of these ostomy complications. Age was inversely related to severity of all 3 ostomy complications (skin irritation, leakage, and difficulty adjusting). Having an ileostomy, rather than a colostomy, was associated with higher severity of skin irritation. Having had the stoma site marked preoperatively was associated with less difficulty adjusting to an ostomy, and having had preoperative ostomy education was associated with less severe problems with skin irritation and leakage. Severity of each ostomy complication predicted total quality-of-life scores. Difficulty adjusting to the ostomy was related to all 4 quality-of-life domains (physical, psychological, social, and spiritual). This study found important relationships between demographic and clinical factors and ostomy complications. Skin problems, leakage, and difficulty adjusting predicted total quality of life scores and domains. Establishing relationships among ostomy complications and demographic, clinical factors, and quality of life can enhance identification of patients at risk for the development of complications and is an important first step in identifying the development of effective interventions to reduce the negative impact of complications for people with ostomies. Further study of predictors and outcomes of ostomy complications is needed to improve care.
46 CFR Appendix C to Subpart C to... - Medical Surveillance Guidelines for Benzene
Code of Federal Regulations, 2010 CFR
2010-10-01
... produce primary irritation due to repeated or prolonged contact with the skin. High concentrations are... Direct skin contact with benzene may cause erythema. Repeated or prolonged contact may result in drying, scaling dermatitis or development of secondary skin infections. In addition, benzene is absorbed through...
16 CFR 1500.41 - Method of testing primary irritant substances.
Code of Federal Regulations, 2012 CFR
2012-01-01
... example: Skin reaction Exposure time (hours) Evaluation value Erythema and eschar formation: Intact skin... patches are removed and the resulting reactions are evaluated on the basis of the designated values in the following table: Skin reaction Value 1 Erythema and eschar formation: No erythema 0 Very slight erythema...
Aggarwal, Geeta; Dhawan, Sanju; HariKumar, S L
2012-03-01
The feasibility of development of transdermal delivery system of olanzapine utilizing natural oils as permeation enhancers was investigated. Penetration enhancing potential of corn (maize) oil, groundnut oil and jojoba oil on in vitro permeation of olanzapine across rat skin was studied. The magnitude of flux enhancement factor with corn oil, groundnut oil and jojoba oil was 7.06, 5.31 and 1.9 respectively at 5mg/ml concentration in solvent system. On the basis of in vitro permeation studies, eudragit based matrix type transdermal patches of olanzapine were fabricated using optimized concentrations of natural oils as permeation enhancers. All transdermal patches were found to be uniform with respect to physical characteristics. The interaction studies carried out by comparing the results of ultraviolet, HPLC and FTIR analyses for the pure drug, polymers and mixture of drug and polymers indicated no chemical interaction between the drug and excipients. Corn oil containing unsaturated fatty acids was found to be promising natural permeation enhancer for transdermal delivery of olanzapine with greatest cumulative amount of drug permeated (1010.68 μg/cm²/h) up to 24 h and caused no skin irritation. The fabricated transdermal patches were found to be stable. The pharmacokinetic characteristics of the final optimized matrix patch (T2) were determined after transdermal application to rabbits. The calculated relative bioavailability of TDDS was 113.6 % as compared to oral administration of olanzapine. The therapeutic effectiveness of optimized transdermal system was confirmed by tranquillizing activity in rotarod and grip mice model.
The local lymph node assay being too sensitive?
Hans-Werner, Vohr; Jürgen, Ahr Hans
2005-12-01
The local lymph node assay (LLNA) and modifications thereof were recently recognized by the OECD as stand-alone methods for the detection of skin-sensitizing potential. However, although the validity of the LLNA was acknowledged by the ICCVAM, attention was drawn to one major problem, i.e., the possibility of false positive results caused by non-specific cell activation as a result of inflammatory processes in the skin (irritation). This is based on the fact that inflammatory processes in the skin may lead to non-specific activation of dendritic cells, cell migration and non-specific proliferation of lymph node cells. Measuring cell proliferation by radioactive or non-radioactive methods, without taking the irritating properties of test items into account, leads thus to false positive reactions. In this paper, we have compared both endpoints: (1) cell proliferation alone and (2) cell proliferation in combination with inflammatory (irritating) processes. It turned out that a considerable number of tests were "false positive" to the definition mentioned above. By excluding such false positive results the LLNA seems not to be more sensitive than relevant guinea pig assays. These various methods and results are described here.
Cystoscopic diagnosis of polypoid cystitis in two pet rabbits.
Di Girolamo, Nicola; Bongiovanni, Laura; Ferro, Silvia; Melidone, Raffaele; Nicoletti, Annalisa; Duca, Valeria Del; Donnelly, Thomas M; Selleri, Paolo
2017-07-01
CASE DESCRIPTION AS-year-old male Dwarf rabbit and 4-year-old female Mini-Rex rabbit were evaluated because of anorexia and urine scalding of the perineum. CLINICAL FINDINGS Abdominal radiography revealed a diffuse increase in the opacity of the urinary bladder attributable to urinary sludge. In 1 rabbit, abdominal ultrasonography revealed several mass-like lesions protruding from the mucosal surface into the lumen of the urinary bladder. Rabbits were anesthetized, and cystoscopy was performed with a rigid 2.7-mm, 30° endoscope. Histologic analysis of tissue samples obtained through the cystoscope operating channel revealed findings consistent with polypoid cystitis. TREATMENT AND OUTCOME To remove the urinary sludge from each rabbit, the urinary bladder was filled with sterile saline (0.9% NaCl) solution and emptied with a gentle massage several times until the ejected fluid was transparent. Rabbits were treated with NSAIDs, antimicrobials (chosen following microbial culture of urine and antimicrobial susceptibility testing), bathing of the perineum, and a low-calcium diet. The male rabbit died of unrelated causes 18 months later; postmortem examination findings confirmed the polypoid cystitis. The female rabbit remained disease free through to last follow-up (12 months after initial evaluation). CLINICAL RELEVANCE This was the first report of polypoid cystitis in pet rabbits. Although ultrasonographic findings supported this diagnosis, a definitive diagnosis was achieved through cystoscopy and lesion biopsy. Treatments administered were intended to reduce the potential sources of irritation. Research is needed to investigate the effectiveness of the applied interventions and the association between excessive urinary calcium excretion and polyploid cystitis in rabbits.
Laquieze, Sabine; Czernielewski, Janusz; Rueda, Marie-José
2006-01-01
Despite their beneficial effects on the treatment of acne vulgaris, topical and oral retinoids may cause severe local irritation (retinoid dermatitis) due to their mechanism of action, thereby jeopardizing patient adherence, and thus compromising treatment efficacy. Alleviating dryness and improving skin comfort by using a moisturizer concomitantly to retinoids could enhance efficacy. In the present study, 30 subjects receiving either oral isotretinoin for at least 2 months or topical tretinoin for at least one month applied a moisturizing cream (Cetaphil Moisturizing Cream) twice daily for 15 days on one half of the face while the other side remained untreated. Clinical assessments, confirmed by biophysical measurements, showed that the moisturizer provided a significant improvement in skin dryness, roughness, and desquamation. Skin properties and skin discomfort were also greatly improved and subjects were very satisfied with the product. Retinoid-induced skin irritation can be relieved by the regular use of a gentle moisturizing cream as an adjunctive treatment.
Tayel, Saadia Ahmed; El-Nabarawi, Mohamed Ahmed; Tadros, Mina Ibrahim; Abd-Elsalam, Wessam Hamdy
2013-02-25
Terbinafine hydrochloride (T-HCl) is recommended for the management of fungal keratitis. To maintain effective aqueous humor concentrations, frequent instillation of T-HCl drops is necessary. This work aimed to develop alternative controlled-release in situ ocular drug-loaded nanoemulsion (NE) gels. Twelve pseudoternary-phase diagrams were constructed using oils (isopropyl myristate/Miglyol 812), surfactants (Tween 80/Cremophor EL), a co-surfactant (polyethylene glycol 400) and water. Eight drug-loaded (0.5%, w/v) NEs were evaluated for thermodynamic stability, morphology, droplet size and drug release in simulated tear fluid (pH 7.4). Following dispersion in gellan gum solution (0.2%, w/w), the in situ NE gels were characterized for transparency, rheological behavior, mucoadhesive force, drug release and histopathological assessment of ocular irritation. Drug pharmacokinetics of sterilized F31 [Miglyol 812, Cremophor EL: polyethylene glycol 400 (1:2) and water (5, 55 and 40%, w/w, respectively)] in situ NE gel and oily drug solution were evaluated in rabbit aqueous humor. The NEs were thermodynamically stable and have spherical droplets (<30 nm). The gels were transparent, pseudoplastic, mucoadhesive and showed more retarded zero-order drug release rates. F31 in situ NE gel showed the least ocular irritation potential and significantly (P<0.01) higher C(max), delayed T(max), prolonged mean residence time and increased bioavailability. Copyright © 2013 Elsevier B.V. All rights reserved.
Tuetun, B; Choochote, W; Pongpaibul, Y; Junkum, A; Kanjanapothi, D; Chaithong, U; Jitpakdi, A; Riyong, D; Pitasawat, B
2008-12-01
Celery-based products were investigated for chemical composition, skin irritation, and mosquito repellency in comparison to commercial repellents and the standard chemical, N,N-diethyl-3-methylbenzamide (DEET), with a goal to develop a natural alternative to synthetic repellents for protection against mosquitoes. Chemical identification by gas chromatography coupled with mass spectrometry discovered that the major constituents of Apium graveolens hexane extract (AHE) were 3-n-butyl-tetrahydrophthalide (92.48%), followed by 5.10% beta-selinene and 0.68% gamma-selinene. Evaluation of skin irritation in 27 human volunteers revealed no irritant potential from 25% ethanolic AHE solution. Laboratory investigated repellent against female Aedes aegypti mosquitoes demonstrated that G10 formula, the best AHE-developed product, provided remarkable repellency with a median protection time of 4.5 h (4.5-5 h), which was greater than that of ethanolic DEET solution (25% DEET, 3.5 h) and comparable to that of the best commercial repellent, Insect Block 28 (28.5% DEET, 4.5 h). According to significantly promising results, including highly effective repellency and no potential skin irritation or other side effects, the G10 formula is a worthwhile product that has the promise of being developed for commercialized registration. This developed AHE product could be an acceptable and affordable alternative to conventional synthetic chemicals in preventing mosquito bites, and in turn, helping to interrupt mosquito-borne disease transmission.
Beneficial effects of softened fabrics on atopic skin.
Hermanns, J F; Goffin, V; Arrese, J E; Rodriguez, C; Piérard, G E
2001-01-01
There is general concern about the possible cutaneous adverse effects of wearing garments treated with household laundry products, particularly on atopic skin. Our objective was to compare softened and non- softened fabrics in a forearm wet and dry test, under conditions simulating real-life conditions. Twenty atopic volunteers entered a single-blind 12-day (3 sessions per day) forearm wetting and drying test. Cotton fabrics were machine washed and liquid fabric conditioner was added or not to the final rinse. To simulate conditions of skin damage, a dilute solution of sodium lauryl sulphate was applied under occlusion to the forearm of each volunteer before the start of the study. Skin effects were evaluated by visual grading (redness, dryness and smoothness), squamometry and in vivo instrumental measurements (capacitance, transepidermal water loss and colorimetry). Rubbing of atopic skin with fabrics generally resulted in discrete to moderate alterations of the structure of the stratum corneum. Both for control and pre-irritated skin, all measured parameters indicated that softened fabric was less aggressive to the skin than unsoftened fabric. In the case of pre-irritated skin, the recovery of the skin was significantly faster when rubbed with softened than with unsoftened fabrics. In conclusion, softened fabrics help mitigate the skin condition in atopic patients. Copyright 2001 S. Karger AG, Basel.
Strupp, Christian
2011-01-01
The toxicity of soluble metal compounds is often different from that of the parent metal. Since no reliable data on acute toxicity, local effects, and mutagenicity of beryllium metal have ever been generated, beryllium metal powder was tested according to the respective Organisation for Economical Co-Operation and Development (OECD) guidelines. Acute oral toxicity of beryllium metal was investigated in rats and local effects on skin and eye in rabbits. Skin-sensitizing properties were investigated in guinea pigs (maximization method). Basic knowledge about systemic bioavailability is important for the design of genotoxicity tests on poorly soluble substances. Therefore, it was necessary to experimentally compare the capacities of beryllium chloride and beryllium metal to form ions under simulated human lung conditions. Solubility of beryllium metal in artificial lung fluid was low, while solubility in artificial lysosomal fluid was moderate. Beryllium chloride dissolution kinetics were largely different, and thus, metal extracts were used in the in vitro genotoxicity tests. Genotoxicity was investigated in vitro in a bacterial reverse mutagenicity assay, a mammalian cell gene mutation assay, a mammalian cell chromosome aberration assay, and an unscheduled DNA synthesis (UDS) assay. In addition, cell transformation was tested in a Syrian hamster embryo cell assay, and potential inhibition of DNA repair was tested by modification of the UDS assay. Beryllium metal was found not to be mutagenic or clastogenic based on the experimental in vitro results. Furthermore, treatment with beryllium metal extracts did not induce DNA repair synthesis, indicative of no DNA-damaging potential of beryllium metal. A cell-transforming potential and a tendency to inhibit DNA repair when the cell is severely damaged by an external stimulus were observed. Beryllium metal was also found not to be a skin or eye irritant, not to be a skin sensitizer, and not to have relevant acute oral toxic properties.
1981-02-11
GROUND, MD 21010 TOPICAL HAZARD EVALUATION PROGRAM OF CANDIDATE INSECT REPELLENT AI 3- 20816 -aUS DEPARTMENT OF AGRICULTURE PROPRIETARY COMPOUND STUDY NO...irritation A13- 20816 -a Photochemical irritation Topical Hazard Evaluation Sensitization Candidate repellent ALD Skin irritation 20. ABSTRACT (Continue an...reverse e e if necessary and identify by block number) A hazard evaluation of candidate insect repellent A13- 20816 -a was performed by means of laboratory
40 CFR 721.1150 - Substituted polyglycidyl ben-zena-mine.
Code of Federal Regulations, 2011 CFR
2011-07-01
... following information: WARNING: CONTACT WITH SKIN AND EYES IS HARMFUL —Severe skin and eye irritant.... They have also caused allergic reactions in humans. —Prevent all contact with skin, eyes, and clothing... water. FIRST AID: —In case of eye contact, immediately flush with plenty of water and get immediate...
Closure of large wounds using rubber bands in rabbits.
Magalhães, Maria Angélica Baron; Petroianu, Andy; Martins, Silmar Grey de Oliveira; Resende, Vivian; Alberti, Luiz Ronaldo; Barbosa, Alfredo José Afonso; Vasconcellos, Leonardo de Souza; Tavares Junior, Wilson Campos
2015-01-01
to verify the effectiveness of the rubber elastic band in the treatment of large wounds of the body wall of rabbits by means of traction of its edges. we studied 30 New Zealand rabbits, divided into three groups (n=10): Group 1- healing by secondary intention; Group 2- removal and eutopic repositioning of skin as full thickness skin graft; Group 3- Approximation of wound edges with elastic rubber band. In all animals, we removed a segment of the back skin and subcutaneous tissue down to the fascia, in accordance with an acrylic mold of 8 cm long by 12 cm wide. All animals were observed for 21 days. two animals of groups 1 and 2 had wound abscess. In Group 2, there was partial or total graft loss in 90% of animals. The complete closure of the wounds was observed in four animals of Group 1, six of Group 2 and eight of Group 3. There was no difference between the scar resistance values of groups 2 and 3, which were higher than those in Group 1. The scars of the three groups were characterized by the presence of mature connective tissue mixed with blood vessels and inflammatory infiltration, predominantly polymorphonuclear. the tensile strength of the wound edges with rubber elastic band is as efficient as the skin graft to treat rabbits' large body wounds.
Cutaneous irritancy of an ibuprofen medicated plaster in healthy volunteers.
Maganji, Manisha; Connolly, Mark P; Bhatt, Aomesh
2018-01-01
Ibuprofen is a commonly used non-steroidal anti-inflammatory drug administered to treat injuries, joint pain, and recurrent muscular skeletal pain. The aim of this study was to determine the cutaneous irritancy of a medicated ibuprofen plaster compared with a placebo plaster in healthy volunteers. Healthy volunteers (N = 31) were treated at the same time with one ibuprofen and one placebo plaster. The ibuprofen and placebo plaster were applied in a randomized fashion to sites on the left or right side of subjects' lower backs. At each scheduled visit, the plasters and applications sites were assessed for degree of adhesion and skin irritancy, respectively. The plasters were applied on study Days 1, 2, 3, 5, 8, 10, 12, 15, 17, and 19, with final plaster removal on Day 22. The ibuprofen medicated plaster compared with placebo had a lower percentage of Grade 1 (23.3% vs. 46.7%, respectively), Grade 2 (10% vs. 20%), and ≥Grade 3 (3% vs. 16.1%) irritancy scores after 21 days of application. The mean irritation score across the study was 0.40 for the ibuprofen medicated plaster and 1.18 for the placebo plaster. The irritation score on Day 22 of the study was 0.53 for the ibuprofen medicated plaster and 1.50 for placebo. The placebo plaster was associated with a higher number of stopped applications due to Grade 3 or above skin reactions compared with the ibuprofen medicated plaster (5 vs. 1, respectively). The ibuprofen medicated plaster was well tolerated and was associated with lower irritancy than the placebo plaster.
DOE Office of Scientific and Technical Information (OSTI.GOV)
el-Mofty, M.M.; Sakr, S.A.; Younis, M.W.
Bed bugs, Cimex lectularius, irradiated with gamma rays were allowed to suck blood from shaved areas of the skin of rabbits, Oryctolagus cuniculus, 2 times/week for 5 months and then once weekly for another 5 months. This significantly induced the formation of skin papillomas and sweat gland hyperplasia in five out of nine experimental animals. It is speculated that the saliva of the irradiated bugs was activated by gamma rays and was responsible for the induction of skin papillomas. Because bed bugs play a significant role in the transmission of virus, it is also speculated that there is a virusmore » in the saliva of bugs; this virus may be activated by gamma radiation and causes the development of papillomas in the skin.« less
Adriaens, E; Guest, R; Willoughby, J A; Fochtman, P; Kandarova, H; Verstraelen, S; Van Rompay, A R
2018-06-01
Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. The objective of CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for eye irritation assessment that can lead to complete replacement of the in vivo Draize rabbit eye test (OECD TG 405). A set of 80 reference chemicals was tested with seven test methods, one method was the Slug Mucosal Irritation (SMI) test method. The method measures the amount of mucus produced (MP) during a single 1-hour contact with a 1% and 10% dilution of the chemical. Based on the total MP, a classification (Cat 1, Cat 2, or No Cat) is predicted. The SMI test method correctly identified 65.8% of the Cat 1 chemicals with a specificity of 90.5% (low over-prediction rate for in vivo Cat 2 and No Cat chemicals). Mispredictions were predominantly unidirectional towards lower classifications with 26.7% of the liquids and 40% of the solids being underpredicted. In general, the performance was better for liquids than for solids with respectively 76.5% vs 57.1% (Cat 1), 61.5% vs 50% (Cat 2), and 87.5% vs 85.7% (No Cat) being identified correctly. Copyright © 2017 Elsevier Ltd. All rights reserved.
Szél, E; Polyánka, H; Szabó, K; Hartmann, P; Degovics, D; Balázs, B; Németh, I B; Korponyai, C; Csányi, E; Kaszaki, J; Dikstein, S; Nagy, K; Kemény, L; Erős, G
2015-12-01
Glycerol is known to possess anti-irritant and hydrating properties and previous studies suggested that xylitol may also have similar effects. Our aim was to study whether different concentrations of these polyols restore skin barrier function and soothe inflammation in sodium lauryl sulphate (SLS)-induced acute irritation. The experiments were performed on male SKH-1 hairless mice. The skin of the dorsal region was exposed to SLS (5%) for 3 h alone or together with 5% or 10% of glycerol respectively. Further two groups received xylitol solutions (8.26% and 16.52% respectively) using the same osmolarities, which were equivalent to those of the glycerol treatments. The control group was treated with purified water. Transepidermal water loss (TEWL) and skin hydration were determined. Microcirculatory parameters of inflammation were observed by means of intravital videomicroscopy (IVM). Furthermore, accumulation of neutrophil granulocytes and lymphocytes, the expression of inflammatory cytokines and SLS penetration were assessed, as well. Treatment with the 10% of glycerol and both concentrations of xylitol inhibited the SLS-induced elevation of TEWL and moderated the irritant-induced increase in dermal blood flow and in the number of leucocyte-endothelial interactions. All concentrations of the applied polyols improved hydration and prevented the accumulation of lymphocytes near the treatment site. At the mRNA level, neither glycerol nor xylitol influenced the expression of interleukin-1 alpha. However, expression of interleukin-1 beta was significantly decreased by the 10% glycerol treatment, while expression of tumour necrosis factor-alpha decreased upon the same treatment, as well as in response to xylitol. Higher polyol treatments decreased the SLS penetration to the deeper layers of the stratum corneum. Both of the analysed polyols exert considerable anti-irritant and anti-inflammatory properties, but the effective concentration of xylitol is lower than that of glycerol. © 2015 European Academy of Dermatology and Venereology.
Caustic ulcers caused by cement aqua: report of a case.
Machovcova, Alena
2010-01-01
Chromium is widely used in various industries including construction sector. Skin contact with cement has been associated with allergic or irritant contact dermatitis. Contact dermatitis is one of the most frequently reported health problems among construction workers. Irritant contact dermatitis from cement ranges from cement burns to cumulative irritant contact dermatitis. Cement burns are rarely reported and are considered a severe form of acute irritant contact dermatitis. They are associated with amateur user working in a short ready-mix time-frame with poor protective measures. They usually result in significant morbidity and initially are associated with minimal discomfort. We report a typical case.
The skin sensitization potential of four alkylalkanolamines.
Leung, H W; Blaszcak, D L
1998-04-01
The skin sensitization potential of 4 alkylalkanolamines (N-methylethanolamine, N,N-dimethylethanolamine, N-methyldiethanolamine and N,N-diethylethanolamine), was evaluated in a guinea pig maximation procedure by the method of Magnusson and Kligman. While all 4 alkylalkanolamines tested were irritating to the guinea pig skin, only N-methylethanolamine showed potential to induce allergic contact dermatitis. None of the remaining 3 alkylalkanolamines exhibited clear skin responses suggestive of sensitization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang Li; Tanaka, Michiko; Kawaguchi, Yasushi
2004-11-10
Previous results indicated that the herpes simplex virus 1 (HSV-1) U{sub L}31 gene is necessary and sufficient for localization of the U{sub L}34 protein exclusively to the nuclear membrane of infected Hep2 cells. In the current studies, a bacterial artificial chromosome containing the entire HSV-1 strain F genome was used to construct a recombinant viral genome in which a gene encoding kanamycin resistance was inserted in place of 262 codons of the 306 codon U{sub L}31 open reading frame. The deletion virus produced virus titers approximately 10- to 50-fold lower in rabbit skin cells, more than 2000-fold lower in Veromore » cells, and more than 1500-fold lower in CV1 cells, compared to a virus bearing a restored U{sub L}31 gene. The replication of the U{sub L}31 deletion virus was restored on U{sub L}31-complementing cell lines derived either from rabbit skin cells or CV1 cells. Confocal microscopy indicated that the majority of U{sub L}34 protein localized aberrantly in the cytoplasm and nucleoplasm of Vero cells and CV1 cells, whereas U{sub L}34 protein localized at the nuclear membrane in rabbit skin cells, and U{sub L}31 complementing CV1 cells infected with the U{sub L}31 deletion virus. We conclude that rabbit skin cells encode a function that allows proper localization of U{sub L}34 protein to the nuclear membrane. We speculate that this function partially complements that of U{sub L}31 and may explain why U{sub L}31 is less critical for replication in rabbit skin cells as opposed to Vero and CV1 cells.« less
Abo, Takayuki; Hilberer, Allison; Behle-Wagner, Christine; Watanabe, Mika; Cameron, David; Kirst, Annette; Nukada, Yuko; Yuki, Takuo; Araki, Daisuke; Sakaguchi, Hitoshi; Itagaki, Hiroshi
2018-04-01
The Short Time Exposure (STE) test method is an alternative method for assessing eye irritation potential using Statens Seruminstitut Rabbit Cornea cells and has been adopted as test guideline 491 by the Organisation for Economic Co-operation and Development. Its good predictive performance in identifying the Globally Harmonized System (GHS) No Category (NC) or Irritant Category has been demonstrated in evaluations of water-soluble substances, oil-soluble substances, and water-soluble mixtures. However, the predictive performance for oil-soluble mixtures was not evaluated. Twenty-four oil-soluble mixtures were evaluated using the STE test method. The GHS NC or Irritant Category of 22 oil-soluble mixtures were consistent with that of a Reconstructed human Cornea-like Epithelium (RhCE) test method. Inter-laboratory reproducibility was then confirmed using 20 water- and oil-soluble mixtures blind-coded. The concordance in GHS NC or Irritant Category among four laboratories was 90%-100%. In conclusion, the concordance in comparison with the results of RhCE test method using 24 oil-soluble mixtures and inter-laboratory reproducibility using 20 water- and oil-soluble mixtures blind-coded were good, indicating that the STE test method is a suitable alternative for predicting the eye irritation potential of both substances and mixtures. Copyright © 2018 Elsevier Ltd. All rights reserved.
Assessment of test method variables for in vitro skin irritation testing of medical device extracts.
Olsen, Daniel S; Lee, Michelle; Turley, Audrey P
2018-08-01
Skin irritation is an important component of the biological safety evaluation of medical devices. This testing has typically been performed using in vivo models. However, in an effort to reduce the need for in vivo testing, alternative methods for assessing skin irritation potential in vitro have been developed using a Reconstructed Human Epidermis (RhE) model. During the development of the protocol for the round robin validation of in vitro irritation testing for medical device extracts, it became clear that there were three points in the procedure where different options may be validated within each laboratory for routine testing: sample exposure time (18 vs 24h), SDS positive control concentration, and cytokine (IL-1α) release testing. The goal of our study was to evaluate the effect of these variables. EpiDerm™ tissues were exposed to extracts of three plain polymer samples, and four polymers embedded with known irritant chemicals. Exposures were performed for 18 and 24h. Resulting tissue viability was assessed by MTT reduction and IL-1α release was assessed by ELISA. Testing was also performed using various concentrations of SDS ranging from 0.5 to 1% (w/v). Overall, results were similar for samples tested and 18 and 24h, but the 18h exposure time has the potential to have an impact on the results of some sample types. IL-1α testing was shown to be useful to clarify conflicting tissue viability results. Use of a lower concentration of SDS as a positive control can help prevent issues that arise from excessive tissue damage often caused by 1% SDS. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Heat loss regulation: role of appendages and torso in the deer mouse and the white rabbit.
Conley, K E; Porter, W P
1985-01-01
Thermal conductance was subdivided into the component conductances of the appendages and torso using a heat transfer analysis for the deer mouse, Peromyscus maniculatus, and the white rabbit, Oryctolagus cuniculus. Our analysis was based on laboratory measurements of skin temperature and respiratory gas exchange made between air temperatures of 8 and 34 degrees C for the deer mouse, and from published data for the white rabbit. Two series conductances to heat transfer for each appendage and torso were evaluated: internal (hin), for blood flow and tissue conduction to the skin surface, and external (hex), for heat loss from the skin surface to the environment. These two series conductances were represented in a single, total conductance (htot). The limit to htot was set by hex and was reached by the torso htot of both animals. The increase in torso htot observed with air temperature for the mouse suggests that a pilomotor change in fur depth occurred. A control of htot below the limit set by hex was achieved by the hin of each appendage. Elevation of mouse thermal conductance (C) resulted from increases in feet, tail, and torso htot. In contrast, the rabbit showed no change in torso htot between 5 and 30 degrees C and ear htot exclusively increased C over these air temperatures. We suggest that the hyperthermia reported for the rabbit at 35 degrees C resulted from C reaching the physical limit set by torso and near hex. Thus the ear alone adjusted rabbit C, whereas the feet, tail, and the torso contributed to the adjustment of mouse C.
Liu, Ji-Xin; Sun, Yan-Hong; Li, Chao-Pin
2015-04-01
Demodex is a type of permanent obligatory parasite, which can be found on the human body surface. Currently, drugs targeting Demodex usually result in adverse effects and have a poor therapeutic effect. Thus, the aim of the present study was to investigate the use of Chinese crude medicine volatile oils for targeting and inhibiting Demodex in vitro . The volatile oils of six Chinese crude medicines were investigated, including clove, orange fruit, Manchurian wildginger, cinnamon bark, Rhizome Alpiniae Officinarum and pricklyash peel, which were extracted using a distillation method. The exercise status of Demodex folliculorum and Demodex brevis and the antiparasitic effects of the volatile oils against the two species were observed using microscopy. A skin irritation test was used to examine the irritation intensity of the volatile oils. In addition, an acute toxicity test was utilized to observe the toxicity effects of the volatile oils on the skin. Xin Fumanling ointment was employed as a positive control to identify the therapeutic effects of the volatile oils. The results indicated that all six volatile oils were able to kill Demodex efficiently. In particular, the clove volatile oil was effective in inducing optimized anti- Demodex activity. The lethal times of the volatile oils were significantly decreased compared with the Xin Fumanling ointment (P<0.05). Furthermore, the skin irritation test results indicated that the clove volatile oil did not trigger any irritation (0.2 and 0.3 points for intact and scratched skin, respectively), and had a safety equal to that of distilled water. There were not any adverse effects observed following application of the clove volatile oil on the intact or scratched skin. In conclusion, the volatile oils of Chinese crude medicines, particularly that of clove, demonstrated an evident anti- Demodex activity and were able to kill Demodex effectively and safely in vivo .
Final report of the amended safety assessment of Dioscorea Villosa (Wild Yam) root extract.
2004-01-01
Dioscorea Villosa (Wild Yam) Root Extract is an extract of the rhizomes of the wild yam, D. villosa. A manufacturing process was described in which cut up and ground rhizomes are combined with an eluant (e.g., oleyl alcohol), the plant material precipitated with addition of a miscible solvent, washed, and redissolved in the original eluant. The extract contains glycoside and steroidal saponins (< or =0.4%), diosgenin (< or =3.5%), alkaloids, tannins, phytosterols, and starch. Levels of heavy metals, 1,4-dioxane, chloroform, methylene chloride, trichloroethylene, and benzene are reported to be below limits of detection. Although only one use was reported to the U.S. Food and Drug Administration (in a body and hand preparation), industry reported uses in body and hand creams, lotions, powders, and sprays at a concentration of 0.00001% (equivalent to 0.000002% plant solids), and in moisturizing creams, lotions, powders, and sprays at concentrations up to 15% (equivalent to 0.5% plant solids). Preparations fromD. villosaare used in herbal medicine for treatment of a variety of ailments and by the pharmaceutical industry in the preparation of steroids. Using Dioscorea Villosa (Wild Yam) Root Extract prepared via a specified process, it is possible to produce a stable extract with a narrow range of diosgenin content. The extract produced using this methodology was tested in acute and short-term toxicity tests, dermal irritation tests, a sensitization test, an ocular irritation test, a rat uterotropic assay, and genotoxicity tests. An acute oral toxicity test produced hypoactivity, piloerection, and dyspnea and a death in 1 of 10 rats at 2 g/kg using the specified extract, but no toxicity in rats given 0.5 g/kg. A dermal toxicity test using the specified extract demonstrated no acute toxicity in rats. Both a 7-day local tolerance test and a 28-day dermal toxicity test in rats produced no significant adverse effects at the maximum tested concentration of 10%. A single application of undiluted extract to the intact and abraded skin of rabbits produced sufficient irritation for the test material to be rated"irritant,"but a 10% dilution was not irritating. Undiluted extract was only mildly irritating to the conjuctiva of the rabbit eye; irritation in the iris and cornea was mild and transient. Undiluted extract was not irritating during the induction phase of a guinea pig sensitization study, nor did challenge with a 25% dilution elicit any sensitization. The specified extract at concentrations up to 500 mg/kg/day did not have any estrogenic activity in the juvenile rat uterotrophic assay. Genotoxicity assays in bacterial and mammalian systems were negative, except that Ames test strain TA 1537 was positive at one dose level using the plate incorporation method, but not using a preincubation method. Although the concentration at which the actual plant extract is used in cosmetic products is low, one of the primary safety concerns with this plant extract is the possible metabolic/endocrine activity, e.g., estrogen-like or progesterone-like activity as a result of the presence of small amounts of plant phytosterols such as diosgenin. Extracts prepared as described in this safety assessment, with an upper limit of 3.5% diosgenin, did not have any estrogenic activity, demonstrating that it is possible to produce material that does not present this specific safety concern. Although extracts from pesticide-free plants were not considered genotoxic and it was the view of the Cosmetic Ingredient Review (CIR) Expert Panel that there do not appear to be any components that could be carcinogenic, pesticide residues could raise this issue. It was urged that manufacturers limit pesticide residues to the limit previously used for lanolin of not more than 40 ppm (with not more than 10 ppm for any one residue). Based on these data, it was concluded that Dioscorea Villosa (Wild Yam) Root Extract is safe as used in cosmetic formulations. This conclusion regarding safety, however, is valid only for extracts prepared in a manner that produces a similar chemical profile as that described in this report, particularly as regards diosgenin. Extracts not prepared in a manner that produces a similar chemical profile would be considered safe if they have a similar safety test profile.
... the skin to become scaly and inflamed), and contact dermatitis (caused by direct skin contact with an irritating substance, such as a metal, ... How Do I Get Rid of Eczema Scars? Eczema Impetigo View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & ...
Kolle, Susanne N; Rey Moreno, Maria Cecilia; Mayer, Winfried; van Cott, Andrew; van Ravenzwaay, Bennard; Landsiedel, Robert
2015-07-01
The Bovine Corneal Opacity and Permeability (BCOP) test is commonly used for the identification of severe ocular irritants (GHS Category 1), but it is not recommended for the identification of ocular irritants (GHS Category 2). The incorporation of human reconstructed tissue model-based tests into a tiered test strategy to identify ocular non-irritants and replace the Draize rabbit eye irritation test has been suggested (OECD TG 405). The value of the EpiOcular™ Eye Irritation Test (EIT) for the prediction of ocular non-irritants (GHS No Category) has been demonstrated, and an OECD Test Guideline (TG) was drafted in 2014. The purpose of this study was to evaluate whether the BCOP test, in conjunction with corneal histopathology (as suggested for the evaluation of the depth of the injury( and/or the EpiOcular-EIT, could be used to predict the eye irritation potential of agrochemical formulations according to the UN GHS, US EPA and Brazil ANVISA classification schemes. We have assessed opacity, permeability and histopathology in the BCOP assay, and relative tissue viability in the EpiOcular-EIT, for 97 agrochemical formulations with available in vivo eye irritation data. By using the OECD TG 437 protocol for liquids, the BCOP test did not result in sufficient correct predictions of severe ocular irritants for any of the three classification schemes. The lack of sensitivity could be improved somewhat by the inclusion of corneal histopathology, but the relative viability in the EpiOcular-EIT clearly outperformed the BCOP test for all three classification schemes. The predictive capacity of the EpiOcular-EIT for ocular non-irritants (UN GHS No Category) for the 97 agrochemical formulations tested (91% sensitivity, 72% specificity and 82% accuracy for UN GHS classification) was comparable to that obtained in the formal validation exercise underlying the OECD draft TG. We therefore conclude that the EpiOcular-EIT is currently the best in vitro method for the prediction of the eye irritation potential of liquid agrochemical formulations. 2015 FRAME.
Irritant contact dermatitis due to ammonium bifluoride in two infant twins.
Toledo, Fernando; Silvestre, Juan Francisco; Cuesta, Laura; Bañuls, José
2013-01-01
Ammonium bifluoride is one of the most corrosive acids that may produce severe chemical burns when in contact with skin. This hazardous chemical is widely used in household products. We report two pediatric cases of irritant contact dermatitis after exposure to a rust remover, which contained ammonium bifluoride. © 2011 Wiley Periodicals, Inc.
A mass spectrometer for pain-response monitoring in rats
NASA Astrophysics Data System (ADS)
Elizarov, A. Yu.
2017-06-01
A mass spectrometer with a membrane interface has been used for measuring the relative concentration of carbon dioxide (CO2) released from rat skin in response to thermal irritation and pain stimulus during intraperitoneal propofol-lidocaine anesthesia. It is established that the local anesthetic lidocaine directly influences the central nervous system and induces antinociceptive reaction to thermal irritation.
Final report of the safety assessment of Urea.
2005-01-01
Although Urea is officially described as a buffering agent, humectant, and skin-conditioning agent-humectant for use in cosmetic products, there is a report stating that Urea also is used in cosmetics for its desquamating and antimicrobial action. In 2001, the Food and Drug Administration (FDA) reported that Urea was used in 239 formulations. Concentrations of use for Urea ranged from 0.01% to 10%. Urea is generally recognized as safe by FDA for the following uses: side-seam cements for food contact; an inhibitor or stabilizer in pesticide formulations and formulations applied to animals; internal sizing for paper and paperboard and surface sizing and coating of paper and paper board that contact water-in-oil dairy emulsions, low-moisture fats and oils, moist bakery products, dry solids with surface containing no free fats or oil, and dry solids with the surface of fat or oil; and to facilitate fermentation of wine. Urea is the end product of mammalian protein metabolism and the chief nitrogenous compound of urine. Urea concentrations in muscle, liver, and fetuses of rats increased after a subcutaneous injection of Urea. Urea diffused readily through the placenta and into other maternal and fetal organs. The half-life of Urea injected into rabbits was on the order of several hours, and the reutilization rate was 32.2% to 88.8%. Urea given to rats by a bolus injection or continuous infusion resulted in distribution to the following brain regions: frontal lobe, caudate nucleus, hippocampus, thalamus plus hypothalamus, pons and white matter (corpus callosum). The permeability constant after treatment with Urea of whole skin and the dermis of rabbits was 2.37 +/- 0.13 (x 10(6)) and 1.20 +/- 0.09 (x10(3)) cm/min, respectively. The absorption of Urea across normal and abraded human skin was 9.5% +/- 2.3% and 67.9% +/- 5.6%, respectively. Urea increased the skin penetration of other compounds, including hydrocortisone. No toxicity was observed for Urea at levels as high as 2000 mg/kg in acute oral studies using female rats or mice. No signs of toxicity were observed in male piglets dosed orally with up to 4 g/kg Urea for 5 days. Dogs dosed orally with 5 to 30 g/L Urea for 4 to 10 days had signs of toxicity, including weakness, anorexia, vomiting and retching, diarrhea and a decreased body temperature, which led to a deep torpor or coma. No significant microscopic changes were observed in the skin of male nude mice dermally exposed to 100% Urea for 24 h. No observable effect on fetal development was seen in rats and mice dosed orally with an aqueous solution of Urea (2000 mg/kg) on days 10 and 12 of gestation. The mean number of implants, live fetuses, percent fetal resorptions, mean fetal weight, and percent fetuses malformed were comparable to control group. A detergent containing 15% Urea was injected into pregnant ICR-JCl mice and dams and fetuses had no significant differences when compared to control animals. Urea given orally did not enhance the developmental toxicity of N-nitrosomethylurea. Female Sprague-Dawley rats injected in the uterine horn with 0.05 ml Urea on day 3 (preimplantation) or on day 7 (post implantation) exhibited no maternal mortality or morbidity; a dose-dependent reduction in embryo survival was seen with preimplantation treatment. Urea injected intra-amniotically induces mid-trimester abortions in humans. Urea was not genotoxic in several bacterial and mammalian assays; although in assays where Urea was used at a high concentration, genotoxicity was found, many in in vitro assays. Urea is commonly used in studies of DNA because it causes uncoiling of DNA molecules. Urea was not carcinogenic in Fisher 344 rats or C57B1/6 mice fed diets containing up to 4.5% Urea. Exposure of normal human skin to 60% Urea produced no significant irritation in one study, but 5% Urea was slightly irritating and 20% Urea was irritating in other reports. Burning sensations are the most frequently reported effect of Urea used alone or with other agents in treatment of diseased skin. Overall, there are few reports of sensitization among the many clinical studies that report use of Urea in treatment of diseased skin. The Cosmetic Ingredient Review (CIR) Expert Panel determined the data provided in this report to be sufficient to assess the safety of Urea. The Panel did note that Urea can cause uncoiling of DNA, a property used in many DNA studies, but concluded that this in vitro activity is not linked to any in vivo genotoxic activity. Although noting that formulators should be aware that Urea can increase the percutaneous absorption of other chemicals, the CIR Expert Panel concluded that Urea is safe as used in cosmetic products.
Thermal Threshold Testing for Evaluation of Analgesics in New Zealand White Rabbits
Barter, Linda S; Kwiatkowski, Anna
2013-01-01
We adapted a thermal analgesiometric device developed for cats for use in unrestrained rabbits. A probe composed of an electrical element and temperature sensor was held against shaved skin by using an elasticized band placed circumferentially around the thorax. An inflated bladder located between the probe and elastic maintained constant contact between probe and skin. The probe was heated until the rabbit displayed a behavioral reaction or the safety cutoff of 55 °C was reached. Threshold temperatures in unmedicated rabbits were stable over a 5-h period provided that tests were 15 min or more apart. Careful acclimation and testing resulted in no false-negative responses, and sham testing did not produce false-positive results. When compared with baseline values, thermal thresholds were significantly increased from 30 to 240 min, but not 300 min, after the administration of morphine at 3 mg/kg. Administration of equivalent volumes of saline via the same route had no effect on thermal threshold. This device may be suitable for investigating analgesic pharmacology in rabbits. PMID:23562032
Xu, Yanfeng; Han, Yunlin; Jiang, Binbin; Huang, Lan; Zhu, Hua; Xu, Yuhuan; Yang, Weiling; Qin, Chuan
2016-01-01
The biological effects of different wavelengths of light emitting diode (LED) light tend to vary from each other. Research into use of photobiomodulation for treatment of skin wounds and the underlying mechanisms has been largely lacking. We explored the histopathological basis of the therapeutic effect of photobiomodulation and the relation between duration of exposure and photobiomodulation effect of different wavelengths of LED in a Japanese big-ear white rabbit skin-wound model. Skin wound model was established in 16 rabbits (three wounds per rabbit: one served as control, the other two wounds were irradiated by red and blue LED lights, respectively). Rabbits were then divided into 2 equal groups based on the duration of exposure to LED lights (15 and 30 min/exposure). The number of wounds that showed healing and the percentage of healed wound area were recorded. Histopathological examination and skin expression levels of fibroblast growth factor (FGF), epidermal growth factor (EGF), endothelial marker (CD31), proliferating cell nuclear antigen (Ki67) and macrophagocyte (CD68) infiltration, and the proliferation of skin collagen fibers was assessed. On days 16 and 17 of irradiation, the healing rates in red (15 min and 30 min) and blue (15 min and 30 min) groups were 50%, 37.5%, 25% and 37.5%, respectively, while the healing rate in the control group was 12.5%. The percentage healed area in the red light groups was significantly higher than those in other groups. Collagen fiber and skin thickness were significantly increased in both red light groups; expression of EGF, FGF, CD31 and Ki67 in the red light groups was significantly higher than those in other groups; the expression of FGF in red (30 min) group was not significantly different from that in the blue light and control groups. The effect of blue light on wound healing was poorer than that of red light. Red light appeared to hasten wound healing by promoting fibrous tissue, epidermal and endothelial cell proliferation. An increase in the exposure time to 30 min did not confer any additional benefit in both red and blue light groups. This study provides a theoretical basis for the potential therapeutic application of LED light in clinical settings. PMID:27347879
Evaluation of seven in vitro alternatives for ocular safety testing.
Bruner, L H; Kain, D J; Roberts, D A; Parker, R D
1991-07-01
Seven in vitro assays were evaluated to determine if any were useful as screening procedures in ocular safety assessment. Seventeen test materials (chemicals, household cleaners, hand soaps, dishwashing liquids, shampoos, and liquid laundry detergents) were tested in each assay. In vivo ocular irritation scores for the materials were obtained from existing rabbit low volume eye test (LVET) data. The seven assays evaluated included the silicon microphysiometer (SM), luminescent bacteria toxicity test (LBT), neutral red assay (NR), total protein assay (TP), Tetrahymena thermophila motility assay (TTMA), bovine eye/chorioallantoic membrane assay (BE/CAM), and the EYTEX system (ETS). For the seventeen materials used in this study there was a significant correlation between the in vivo irritant potential and in vitro data for all the tests except the EYTEX System (SM, r = -0.87; LBT, r = -0.91; NR, r = -0.85; TTMA, r = 0.78; TP, r = -0.86; ETS, r = 0.29). The irritation classifications provided by the BE/CAM also did not correspond with the actual in vivo irritancy potential of the test materials. The result of this study suggested it may be possible to classify materials into broad irritancy categories with some of the assays. This would allow their use as screens prior to limited in vivo confirmation in the ocular safety assessment process.
Yu, N; Xun, Y; Jin, D; Yang, H; Hang, T; Cui, H
2010-01-01
The aim of this study was to investigate the effect of two sperminated pullulans (SP) with a different number of amino groups (SP-L, amino group content 0.124 mmol/g polymer; and SP-H, amino group content 0.578 mmol/g polymer) on the permeation of drugs through isolated rabbit corneas. Determination of corneal hydration levels and Draize eye tests were performed to assess the safety of SP both in vitro and in vivo. For 0.2% (w/v) SP-L and 0.2% (w/v) SP-H, the enhancement ratios (ERs) with dexamethasone of 1.34 and 1.42, respectively, were not statistically significant. For ofloxacin, tobramycin and sodium fluorescein, the ERs with 0.2% SP-L were 1.37, 2.02 and 2.12, respectively, and with 0.2% SP-H the ERs were 1.84, 4.69 and 6.87, respectively; these ERs were all statistically significant. Enhancement increased with increasing amino group content of the SP. The improved transcorneal drug absorption via the paracellular route indicated opening of the tight junctions in the corneal epithelium. Irritation tests indicated that 0.2% SP-L and 0.2% SP-H did not damage the corneal tissues.
Sonsmann, F K; Strunk, M; Gediga, K; John, C; Schliemann, S; Seyfarth, F; Elsner, P; Diepgen, T L; Kutz, G; John, S M
2014-05-01
To date, there are no legally binding requirements concerning product testing in cosmetics. This leads to various manufacturer-specific test methods and absent transparent information on skin cleansing products. A standardized in vivo test procedure for assessment of cleansing efficacy and corresponding barrier impairment by the cleaning process is needed, especially in the occupational context where repeated hand washing procedures may be performed at short intervals. For the standardization of the cleansing procedure, an Automated Cleansing Device (ACiD) was designed and evaluated. Different smooth washing surfaces of the equipment for ACiD (incl. goat hair, felt, felt covered with nitrile caps) were evaluated regarding their skin compatibility. ACiD allows an automated, fully standardized skin washing procedure. Felt covered with nitrile as washing surface of the rotating washing units leads to a homogenous cleansing result and does not cause detectable skin irritation, neither clinically nor as assessed by skin bioengineering methods (transepidermal water loss, chromametry). Automated Cleansing Device may be useful for standardized evaluation of the cleansing effectiveness and parallel assessment of the corresponding irritancy potential of industrial skin cleansers. This will allow objectifying efficacy and safety of industrial skin cleansers, thus enabling market transparency and facilitating rational choice of products. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Local and systemic toxicity of JP-8 from cutaneous exposures.
McDougal, James N; Rogers, James V
2004-04-01
Jet propellant-8 (JP-8) jet fuel is a version of commercial jet fuel, Jet A, and is a complex mixture of primarily aliphatic (but also aromatic) hydrocarbons that varies in composition from batch to batch. There is potential for dermal exposure to jet fuels with personnel involved in aircraft refueling and maintenance operations as well as ground personnel. Cutaneous exposures have the potential to cause skin irritation, sensitization or skin cancer. JP-8 has been shown to be irritating and causes molecular changes in the skin of laboratory animals. The mechanisms of some of these effects have been investigated in intact skin and cultured skin cells. Hydrocarbons have also been shown to cause skin cancer with repeated application to the skin. Additionally, there is concern about systemic toxicity from dermal exposures to jet fuels, such as JP-8. Assessing risks from systemic absorption of hydrocarbon components is complex because most of the components are present in the mixture in small quantities (less than 1%). The effect of the fuel as a vehicle, different rates of penetration through the skin and different target organ toxicities all complicate the assessment of the hazards of cutaneous exposures. The purpose of this manuscript is to review studies of local and systemic toxicity of JP-8.
Huang, Huey-Chun; Chang, Tsong-Min
2008-08-01
Stratum corneum intercellular lipids, such as ceramides, play an important role in the regulation of skin water barrier homeostasis and water-holding capacity. Aim To evaluate the potential water retention capacity of control emulsion and three oil-in-water (o/w) emulsions containing ceramide 1, ceramide 3, or both. Fifteen healthy Asian women (age, 20-30 years) with healthy skin, pretreated with sodium lauryl sulfate (SLS), applied the tested emulsions twice daily over a period of 28 days. Skin hydration and transepidermal water loss (TEWL) values were measured on the indicated days with a Corneometer(R)825 and a TEWAMETER TM210, respectively. The maximum increase in skin humidity was reached after 4 weeks, with values of 21.9 +/- 1.8% and 8.9 +/- 0.9% for emulsion C and control emulsion, respectively. The maximum decrease in TEWL was also reached after 4 weeks, with values of 36.7 +/- 4.7% and 5.1 +/- 0.8% for the same emulsions. It can be concluded that all the tested ceramide-containing emulsions improved skin barrier function when compared with untreated skin. There was some indication that ceramides 1 and 3 contained in emulsion C might exert a beneficial synergistic effect on skin biochemical properties, such as skin hydration and TEWL, and play a key role in the protection mechanism against SLS irritation.
Johnson, Wilbur
2004-01-01
Octoxynols are ethoxylated alkylphenols in which the size of the molecule is related to the number of moles of ethylene oxide used in synthesis. Reactions are performed at elevated temperature, under pressure, and in the presence of NaOH. It is possible that the synthesis may leave trace amounts of ethylene oxide, 1,4-dioxane, and unreacted C9 phenols. Octoxynols of various chain lengths as well as octoxynol salts and organic acids function in cosmetics either as surfactants--emulsifying agents, surfactants--cleansing agents, surfactant--solubilizing agents, or surfactants--hydrotropes in a wide variety of cosmetic products at concentrations ranging from 0.0008% to 25%, with most less than 5.0%. The octoxynols are chemically similar to nonoxynols, the safety of which were previously considered. Long-chain nonoxynols (9 and above) were considered safe as used, whereas short-chain nonoxynols (8 and below) were considered safe as used in rinse-off products and safe at concentrations less than 5% in leave-on formulations. Acute exposure of hamsters to Octoxynol-9 by bronchopulmonary lavage produced pneumonia, pulmonary edema, and intra-alveolar hemorrhage. Octoxynol-9 at doses over 1 g/kg was toxic in rats and in mice in acute oral toxicity studies. No significant effects were noted in short-term oral studies of Octoxynol-9 in rats, in subchronic oral studies of Octoxynol-40 in rats and dogs, or in chronic oral studies of Octoxynol-40 in rats. The intraperitoneal LD50 of Octoxynol-9 in rats and mice was around 100 mg/kg. In skin irritation studies, octoxynols ranged from nonirritating to moderately irritating. Octoxynols were not ocular irritants in one rabbit study, but in others there was ocular irritation. No immune system toxicity in CF-1 female mice was noted following the intraperitoneal injection of Octoxynol-9 followed by subcutaneous immunization with sheep red blood cells (SRBCs). Octoxynol-9 produced no humoral and cell-mediated immune responses, or autoimmune response in mice. In the Ames test, Octoxynol-1 was not mutagenic with and without metabolic activation nor was Octoxynol-9 clastogenic. Results for Octoxynol-9 were negative in the following assays: unscheduled DNA synthesis, hypoxanthine guanine phosphoribosyl transferase mutation assay, malignant transformation assay, DNA alkaline unwinding test, and mouse lymphoma thymidine kinase locus forward mutation assay. Ethoxylated alkylphenols are generally considered to be estrogenic in that they mimic the effects of estradiol. Dermal exposure at three dose levels of rats to Octoxynol-9 failed to induce any malformations by category (external, visceral, or skeletal) or by individual anatomical location that were different from controls at statistically significant level. An increased incidence of a vestigial thoracic rib was observed in all dose groups. Octoxynol-9 also did not induce developmental toxicity (number of viable litters, liveborn per litter, percentage survival, birth weight per pup, and weight gain per pup) in female specific pathogen-free CD-1 mice dosed daily by gavage on gestation days 6 through 13. No reproductive toxicity was seen in male albino rats which received 5% Octoxynol-40 in the diet daily for 3 months; however, in an in vitro test, Octoxynol-9 (0.24 mg/ml) totally immobilized all human spermatozoa within 20 s. Women who used Nonoxynol-9 or Octoxynol-9 as spermicides, but who did become pregnant, did not have an increase in the overall risk of fetal malformations. In a human skin irritation study, formulations containing 2.0% Octoxynol-9 were classified as moderately irritating and minimally irritating, respectively, in a 24-h single-insult, occlusive patch test. Octoxynol-9 (1.0%) was classified as a nonirritant in a clinical study of nine subjects patch tested for 4 consecutive days. The skin sensitization potential of Octoxynols-1, -3, -5, -9, and -13 was evaluated using 50 subjects. Octoxynol-1 induced sensitization in two subjects; all other results were negative. No sensitization was observed in the following studies: 8.0% Octoxynol-9 in 103 subjects, 0.5% Octoxynol-9 in 102 subjects, and 0.1% Octoxynol-9 in 206 subjects. Concerns about even trace levels of 1,4-dioxane, ethylene oxide, or unreacted C9 led to the recommendation that levels be limited. Concerns about the ocular irritancy of short-chain octoxynols led to a recommendation that they should not be used in products that will be used in the area surrounding the eyes. A limitation on the use concentration for short-chain octoxynols (8 and below) arose from consideration of the skin sensitization potential of octoxynols and the recognition that the short-chain octoxynols could be absorbed into the skin more than the long-chain octoxynols. Overall, based on the available data, it was concluded that long-chain octoxynols (9 and above) are safe as used, whereas short-chain octoxynols (8 and below) are safe as used in rinse-off products and safe at concentrations less than 5% in leave-on formulations.
Indans, Ian
2002-02-28
There is currently a drive to eliminate animal testing for cosmetics, toiletries and household products; indeed, the European Union Cosmetics Directive aims to prohibit the use of experimental animals for the testing of finished cosmetic products after 2002. At present, national prohibitions are in place in the UK, Germany, Austria and the Netherlands, for the testing of finished cosmetic products and cosmetic ingredients. In the USA animal testing for certain types of finished products is mandatory. Against this background, the currently available regulatory in vitro tests comprise methods for eye irritation, skin corrosivity, genotoxicity, dermal penetration and photoirritation. The draft updates to the Organisation for Economic Co-operation and Development guidelines for eye and skin irritation advocate the use of in vitro or ex vivo methods prior to the commencement of animal studies. At present, testing for these endpoints cannot be completed in vitro, but potentially corrosive substances and products can be classified without the need for animal studies. Regulatory genotoxicity testing can be completed using only in vitro methods, provided that a clear negative outcome is obtained for each test. Data from dermal penetration studies may be used to refine risk assessments. Current developments in areas such as skin sensitisation and skin irritation promise that in the reasonably near future such information may be generated without the use of animals.
Borrego, Leopoldo; Hernández, Noelia; Hernández, Zaida; Peñate, Yeray
2016-05-01
Povidone-iodine solution is an antiseptic that is used worldwide as surgical paint and is considered to have a low irritant potential. Post-surgical severe irritant dermatitis has been described after the misuse of this antiseptic in the surgical setting. Between January 2011 and June 2013, 27 consecutive patients with post-surgical contact dermatitis localized outside of the surgical incision area were evaluated. Thirteen patients were also available for patch testing. All patients developed dermatitis the day after the surgical procedure. Povidone-iodine solution was the only liquid in contact with the skin of our patients. Most typical lesions were distributed in a double lumbar parallel pattern, but they were also found in a random pattern or in areas where a protective pad or an occlusive medical device was glued to the skin. The patch test results with povidone-iodine were negative. Povidone-iodine-induced post-surgical dermatitis may be a severe complication after prolonged surgical procedures. As stated in the literature and based on the observation that povidone-iodine-induced contact irritant dermatitis occurred in areas of pooling or occlusion, we speculate that povidone-iodine together with occlusion were the causes of the dermatitis epidemic that occurred in our surgical setting. Povidone-iodine dermatitis is a problem that is easily preventable through the implementation of minimal routine changes to adequately dry the solution in contact with the skin. © 2015 The International Society of Dermatology.
Topical use of dexpanthenol in skin disorders.
Ebner, Fritz; Heller, Andreas; Rippke, Frank; Tausch, Irene
2002-01-01
Pantothenic acid is essential to normal epithelial function. It is a component of coenzyme A, which serves as a cofactor for a variety of enzyme-catalyzed reactions that are important in the metabolism of carbohydrates, fatty acids, proteins, gluconeogenesis, sterols, steroid hormones, and porphyrins. The topical use of dexpanthenol, the stable alcoholic analog of pantothenic acid, is based on good skin penetration and high local concentrations of dexpanthenol when administered in an adequate vehicle, such as water-in-oil emulsions. Topical dexpanthenol acts like a moisturizer, improving stratum corneum hydration, reducing transepidermal water loss and maintaining skin softness and elasticity. Activation of fibroblast proliferation, which is of relevance in wound healing, has been observed both in vitro and in vivo with dexpanthenol. Accelerated re-epithelization in wound healing, monitored by means of the transepidermal water loss as an indicator of the intact epidermal barrier function, has also been seen. Dexpanthenol has been shown to have an anti-inflammatory effect on experimental ultraviolet-induced erythema. Beneficial effects of dexpanthenol have been observed in patients who have undergone skin transplantation or scar treatment, or therapy for burn injuries and different dermatoses. The stimulation of epithelization, granulation and mitigation of itching were the most prominent effects of formulations containing dexpanthenol. In double-blind placebo-controlled clinical trials, dexpanthenol was evaluated for its efficacy in improving wound healing. Epidermal wounds treated with dexpanthenol emulsion showed a reduction in erythema, and more elastic and solid tissue regeneration. Monitoring of transepidermal water loss showed a significant acceleration of epidermal regeneration as a result of dexpanthenol therapy, as compared with the vehicle. In an irritation model, pretreatment with dexpanthenol cream resulted in significantly less damage to the stratum corneum barrier, compared with no pretreatment. Adjuvant skin care with dexpanthenol considerably improved the symptoms of skin irritation, such as dryness of the skin, roughness, scaling, pruritus, erythema, erosion/fissures, over 3 to 4 weeks. Usually, the topical administration of dexpanthenol preparations is well tolerated, with minimal risk of skin irritancy or sensitization.
Wet Work and Barrier Function.
Fartasch, Manigé
2016-01-01
Wet work defined as unprotected exposure to humid environments/water; high frequencies of hand washing procedures or prolonged glove occlusion is believed to cause irritant contact dermatitis in a variety of occupations. This review considers the recent studies on wet-work exposure and focuses on its influence on barrier function. There are different methods to study the effect of wet work on barrier function. On the one hand, occupational cohorts at risk can be monitored prospectively by skin bioengineering technology and clinical visual scoring systems; on the other hand, experimental test procedures with defined application of water, occlusion and detergents are performed in healthy volunteers. Both epidemiological studies and the results of experimental procedures are compared and discussed. A variety of epidemiological studies analyze occupational cohorts at risk. The measurement of transepidermal water loss, an indicator of the integrity of the epidermal barrier, and clinical inspection of the skin have shown that especially the frequencies of hand washing and water contact/contact to aqueous mixtures seem to be the main factors for the occurrence of barrier alterations. On the other hand, in a single cross-sectional study, prolonged glove wearing (e.g. occlusion for 6 h per shift in clean-room workers) without exposure to additional hazardous substances seemed not to affect the skin negatively. But regarding the effect of occlusion, there is experimental evidence that previously occluded skin challenged with sodium lauryl sulfate leads to an increased susceptibility to the irritant with an aggravation of the irritant reaction. These findings might have relevance for the real-life situation in so far as after occupational glove wearing, the skin is more susceptible to potential hazards to the skin even during leisure hours. © 2016 S. Karger AG, Basel.
In vivo irritation study of Melastoma malabathricum cream formulation on ICR mice
NASA Astrophysics Data System (ADS)
Yasin, Rabiahtul Adarwiyah Mohd; Jemon, Khairunadwa; Nor, Norefrina Shafinaz Md
2016-11-01
Melastoma malabathricum is a traditional herb that is used to treat wound on skin. It has also been proven to have antiviral activity against Herpes Simplex virus type 1 (HSV-1). In this study, M. malabathricum cream formulation was developed by incorporating M. malabathricum aqueous extract into cream base. The safety and biocompatibility of the formulated cream was investigated by topically applying the cream onto the back of ICR mice skin. Treatment with M. malabathricum was found to accelerate wound contraction with less scar formation. The effect of M. malabathricum has prompted a possibility that M. malabathricum might contribute in enhancing the healing process of cutaneous lesion caused by HSV-1. The formulated cream did not cause any skin irritation or adverse effect to ICR mice when topically applied within seven days of exposure.
Assessing occupational exposure to sea lamprey pesticides.
Ceballos, Diana M; Beaucham, Catherine C; Kurtz, Kristine; Musolin, Kristin
2015-01-01
Sea lampreys are parasitic fish found in lakes of the United States and Canada. Sea lamprey is controlled through manual application of the pesticides 3-trifluoromethyl-4-nitrophenol (TFM) and Bayluscide(TM) into streams and tributaries. 3-Trifluoromethyl-4-nitrophenol may cause irritation and central nervous system depression and Bayluscide may cause irritation, dermatitis, blisters, cracking, edema, and allergic skin reactions. To assess occupational exposures to sea lamprey pesticides. We developed a wipe method for evaluating surface and skin contamination with these pesticides. This method was field tested at a biological field station and at a pesticide river application. We also evaluated exposures using control banding tools. We verified TFM surface contamination at the biological station. At the river application, we found surfaces and worker's skin contaminated with pesticides. We recommended minimizing exposures by implementing engineering controls and improved use of personal protective equipment.
Infant Skin Care Products: What Are the Issues?
Kuller, Joanne McManus
2016-10-01
Infant skin is susceptible to dryness and irritation from external factors, including topical skin care products not formulated for the infant's skin. This may increase the risk of contact dermatitis. Parents frequently express concern regarding potential harm from ingredients in skin care products and seek information. This is complicated by several skin care myths. The purpose of this literature review was to provide evidence-based information to educate parents on the use of products for preterm and term infants. Multiple searches using PubMed were conducted including the search terms "infant skin care," "infant products," "infant bath," "emollients," "diaper skin care," and "diaper wipes." Reference lists of comprehensive reviews were also scanned. Google searches were used to assess consumer information, product information, and regulatory guidelines. There is little scientific evidence to support safety of natural/organic products on infant skin. Raw materials originate from different sources, complicating testing and comparisons of ingredients. Research shows that cleansers formulated for infant skin do not weaken the skin barrier the way harsher soaps and detergents can. Oils with the lowest oleic acid content provide a lower risk of irritant contact dermatitis. Nurses must be informed about natural and organic products, preservatives, and fragrances and know the definition of commonly used marketing terms. Decisions regarding the use of infant products in preterm and term infants should be evidence based. More research is needed to support claims regarding the safety of products used on infant skin.
Effect of photon energy in collagen generation by interstitial low level laser stimulation
NASA Astrophysics Data System (ADS)
Jun, Eunkwon; Ha, Myungjin; Lee, Sangyeob; Radfar, Edalat; Park, Jihoon; Jung, Byungjo
2015-03-01
Although the mechanism of low level laser therapy (LLLT) is unclear, many studies demonstrated the positive clinical performance of LLLT for skin rejuvenation. An increase in dermal collagen plays an important role in skin rejuvenation and wound healing. This study aimed to investigate collagen generation after interstitial low level laser stimulation (ILLS). Rabbits were divided into two groups: surfacing irradiation and minimally invasive irradiation. 660nm diode laser of 20mW with 10J, 13J and 15J was applied to the backside of rabbits. Collagen formation was evaluated with ultrasound skin scanner every 12 hours. Results shows that ILLS groups have denser collagen density than surfacing groups.
Zhou, Dan; Guo, Yi; Guo, Yong-Ming; Zhang, Sai; Pan, Ping
2011-12-01
To investigate the distribution and permeability of blood vessels on the Conception Vessel and the Governor Vessel in the physiological state. Evans blue (EB) solution was injected into the marginal ear vein of healthy rabbits. Three hours after injection, the rabbits were sacrificed and the skin on the Conception Vessel and the Governor Vessel and the corresponding bilateral non-channels was collected. EB was extracted with 7:3 acetone: physiological saline, and the absorbance of EB at each skin tissue was measured with a spectrophotometer. The A value of EB absorbance at the Conception Vessel on the abdominal skin was lower than that of the corresponding bilateral non-channels with a statistically significant difference (P< 0.01). The A value of EB absorbance at the Governor Vessel on the back was higher than that of the corresponding bilateral non-channels (P < 0.05). There was no statistical difference in the A value of EB absorbance between the bilateral non-channels of the abdomen and the back (P > 0.05). There were differences in capillary distribution and permeability between the Conception Vessel, the Governor Vessel and the corresponding bilateral non-meridians.
Late skin damage in rabbits and monkeys after exposure to particulate radiations
NASA Technical Reports Server (NTRS)
Bergtold, D. S.; Cox, A. B.; Lett, J. T.; Su, C. M.
1983-01-01
Preliminary results are reported of experiments on the late effects of exposure to particulate radiations on stem cell populations. Skin biopsies were taken from the ears of rabbits irradiated 2-5 years previously with 530 MeV/amu Ar ions (LET 90 keV/micron), or 365 MeV/amu Ne ions (LET 35 keV micron), and from the chests and inner thighs of rhesus monkeys irradiated 16-18 years previously with 32-MeV protons (LET about 1.2 keV/micron). Skin fibroblast cultures obtained from the biopsy samples in rabbits were observed to undergo dose-dependent decreases in in vitro life span, with estimated survival curves showing the effects of Ar-ion irradiation to be more severe than those of Ne-ion irradiation. In addition, the healing of the biopsy wound was observed to become slower as radiation dose increased. In the monkey, radiation reduced the average number of fibroblasts at the time of cessation of growth in culture. Results thus demonstrate the capacity of skin sampling to reveal stem cell destruction, and have important implications for astronauts and other persons at risk of particle exposure with regard to healing responses to trauma or surgery.
Wu, Edward C.; Sun, Victor; Manuel, Cyrus T.; Protsenko, Dmitriy E.; Jia, Wangcun; Nelson, J. Stuart; Wong, Brian J. F.
2014-01-01
Laser cartilage reshaping (LCR) with cryogen spray cooling is a promising modality for producing cartilage shape change while reducing cutaneous thermal injury. However, LCR in thicker tissues, such as auricular cartilage, requires higher laser power, thus increasing cooling requirements. To eliminate the risks of freeze injury characteristic of high cryogen spray pulse rates, a carbon dioxide (CO2) spray, which evaporates rapidly from the skin, has been proposed as the cooling medium. This study aims to identify parameter sets which produce clinically significant reshaping while producing minimal skin thermal injury in LCR with CO2 spray cooling in ex vivo rabbit auricular cartilage. Excised whole rabbit ears were mechanically deformed around a cylindrical jig and irradiated with a 1.45-μm wavelength diode laser (fluence 12–14 J/cm2 per pulse, four to six pulse cycles per irradiation site, five to six irradiation sites per row for four rows on each sample) with concomitant application of CO2 spray (pulse duration 33–85 ms) to the skin surface. Bend angle measurements were performed before and after irradiation, and the change quantified. Surface temperature distributions were measured during irradiation/cooling. Maximum skin surface temperature ranged between 49.0 to 97.6 °C following four heating/cooling cycles. Significant reshaping was achieved with all laser dosimetry values with a 50–70 °C difference noted between controls (no cooling) and irradiated ears. Increasing cooling pulse duration yielded progressively improved gross skin protection during irradiation. CO2 spray cooling may potentially serve as an alternative to traditional cryogen spray cooling in LCR and may be the preferred cooling medium for thicker tissues. Future studies evaluating preclinical efficacy in an in vivo rabbit model are in progress. PMID:23307439
Wu, Edward C; Sun, Victor; Manuel, Cyrus T; Protsenko, Dmitriy E; Jia, Wangcun; Nelson, J Stuart; Wong, Brian J F
2013-11-01
Laser cartilage reshaping (LCR) with cryogen spray cooling is a promising modality for producing cartilage shape change while reducing cutaneous thermal injury. However, LCR in thicker tissues, such as auricular cartilage, requires higher laser power, thus increasing cooling requirements. To eliminate the risks of freeze injury characteristic of high cryogen spray pulse rates, a carbon dioxide (CO2) spray, which evaporates rapidly from the skin, has been proposed as the cooling medium. This study aims to identify parameter sets which produce clinically significant reshaping while producing minimal skin thermal injury in LCR with CO2 spray cooling in ex vivo rabbit auricular cartilage. Excised whole rabbit ears were mechanically deformed around a cylindrical jig and irradiated with a 1.45-μm wavelength diode laser (fluence 12-14 J/cm(2) per pulse, four to six pulse cycles per irradiation site, five to six irradiation sites per row for four rows on each sample) with concomitant application of CO2 spray (pulse duration 33-85 ms) to the skin surface. Bend angle measurements were performed before and after irradiation, and the change quantified. Surface temperature distributions were measured during irradiation/cooling. Maximum skin surface temperature ranged between 49.0 to 97.6 °C following four heating/cooling cycles. Significant reshaping was achieved with all laser dosimetry values with a 50-70 °C difference noted between controls (no cooling) and irradiated ears. Increasing cooling pulse duration yielded progressively improved gross skin protection during irradiation. CO2 spray cooling may potentially serve as an alternative to traditional cryogen spray cooling in LCR and may be the preferred cooling medium for thicker tissues. Future studies evaluating preclinical efficacy in an in vivo rabbit model are in progress.
... ounces (60 milliliters) of water, orange juice, or grape juice before taking it. If any of the juice gets on the dropper, rinse the dropper with tap water before replacing it in the bottle. Do not allow the liquid concentrate to touch your skin or clothing; it can irritate your skin. If ...
Amended final report of the safety assessment of Drometrizole as used in cosmetics.
2008-01-01
Drometrizole is used in cosmetics as an ultraviolet (UV) light absorber and stabilizer. In an earlier safety assessment, the available data were found insufficient to support the safety of this ingredient, but new data have been provided and assessed. In voluntary industry reports to the Food and Drug Administration, this ingredient is reported to be used in noncoloring hair care products, and in an industry use concentration survey, uses in nail care products at 0.07% were reported. Drometrizole has absorbance maxima at 243, 298, and 340 nm. Drometrizole is used widely as a UV absorber and stabilizer in plastics, polyesters, celluloses, acrylates, dyes, rubber, synthetic and natural fibers, waxes, detergent solutions, and orthodontic adhesives. It is similarly used in agricultural products and insecticides. Drometrizole is approved as an indirect food additive for use as an antioxidant and/or stabilizer in polymers. Short-term studies using rats reported liver weight increases, increases in the activities of enzymes aminopyrine N-demethylase, and UDP glucuronosyl transferase, but no significant effects were noted in the activities of acid hydrolases or in hepatocyte organelles. Although Drometrizole is insoluble in water and soluble in a wide range of organic solvents, a distribution and elimination study using rats indicated that some Drometrizole was absorbed, then metabolized and excreted in the urine. Drometrizole and products containing Drometrizole were nontoxic in acute oral, inhalation, and dermal studies using animals. No increase in mortality or local and/or systemic toxicity were observed in a 13-week oral toxicity study using dogs; the no observed effect level (NOEL) was 31.75 mg/kg day(- 1) for males and 34.6 mg/kg day(-1) for females. In a 2-year feeding study using rats, a NOEL of 47 to 58 mg/kg day(- 1) was reported. Developmental studies of Drometrizole in rats and mice found no teratogenic effects and a NOEL of 1000 mg/kg day(- 1) was reported. Drometrizole was not genotoxic in Ames tests, a mouse bone marrow micronucleus test, or somatic mutation assays observing interphase nuclei and chromosomal aberrations using Chinese hamsters. There was no evidence of dominant lethal effects in studies using mice or rats. Drometrizole at a 1% concentration was minimally to moderately irritating to rabbit eyes, if followed by rinsing, but mildly to severely irritating in unrinsed eyes. A nail product containing 0.03% Drometrizole, however, was nonirritating to unrinsed rabbit eyes. A nail polish containing 1.0% Drometrizole was nonirritating to rabbit skin and Drometrizole was negative for sensitization in two Magnusson-Kligman maximization tests in guinea pigs. In clinical tests, Drometrizole at 1% was nonirritating in a single-insult patch test. No irritation or eczematous reactions were observed in 300 patients (with or without dermatosis) treated with daily applications of Drometrizole for 8 weeks. In a 3-year clinical therapeutic trial conducted to evaluate the effectiveness of two UV absorbing preparations containing up to 5% Drometrizole, two hypersensitivity reactions were observed during 445 applications. Although there are case reports in which Drometrizole was considered the sensitizing agent, clinical tests of cosmetic products containing 0.03% to 1.0% Drometrizole produced no irritation, sensitization, photosensitization, or phototoxicity in a total of 436 subjects. The Cosmetic Ingredient Review (CIR) Expert Panel assumes that Drometrizole is used in both noncoloring hair care and nail care products at low concentrations. The available safety test data do not suggest any adverse effects associated with exposure to Drometrizole. This toxicologic profile, coupled with the low concentration of use and the unlikely dermal penetration of a chemical that is insoluble in water, support the conclusion that Drometrizole can be safely used in cosmetics.
21 CFR 333.350 - Labeling of acne drug products.
Code of Federal Regulations, 2014 CFR
2014-04-01
... allows skin to heal.” (ii) “Penetrates pores to” (select one of the following: “eliminate most,” “control... pimples,” “blackheads,” or “whiteheads”). (iii) “Helps keep skin clear of new” (select one or more of the... labeling states “When using this product [bullet] skin irritation and dryness is more likely to occur if...
21 CFR 333.350 - Labeling of acne drug products.
Code of Federal Regulations, 2013 CFR
2013-04-01
... allows skin to heal.” (ii) “Penetrates pores to” (select one of the following: “eliminate most,” “control... pimples,” “blackheads,” or “whiteheads”). (iii) “Helps keep skin clear of new” (select one or more of the... labeling states “When using this product [bullet] skin irritation and dryness is more likely to occur if...
21 CFR 333.350 - Labeling of acne drug products.
Code of Federal Regulations, 2012 CFR
2012-04-01
... allows skin to heal.” (ii) “Penetrates pores to” (select one of the following: “eliminate most,” “control... pimples,” “blackheads,” or “whiteheads”). (iii) “Helps keep skin clear of new” (select one or more of the... labeling states “When using this product [bullet] skin irritation and dryness is more likely to occur if...
Herbal Supplement in a Buffer for Dry Eye Syndrome Treatment.
Chen, Hung-Chang; Chen, Zhi-Yu; Wang, Tsung-Jen; Drew, Victor J; Tseng, Ching-Li; Fang, Hsu-Wei; Lin, Feng-Huei
2017-08-03
Dry eye syndrome (DES) is one of the most common types of ocular diseases. There is a major need to treat DES in a simple yet efficient way. Artificial tears (AT) are the most commonly used agents for treating DES, but are not very effective. Herbal extractions of ferulic acid (FA), an anti-oxidant agent, and kaempferol (KM), an anti-inflammatory reagent, were added to buffer solution (BS) to replace ATs for DES treatment. The cytotoxicity and anti-inflammatory effects were examined in vitro by co-culture with human corneal epithelial cells (HCECs) to obtain the optimal concentration of KM and FA for treating HCECs. Physical properties of BS, such as pH value, osmolality, and refractive index were also examined. Then, rabbits with DES were used for therapeutic evaluation. Tear production, corneal damage, and ocular irritation in rabbits' eyes were examined. The non-toxic concentrations of KM and FA for HCEC cultivation over 3 days were 1 µM and 100 µM, respectively. Live/dead stain results also show non-toxicity of KM and FA for treating HCECs. Lipopolysaccharide-stimulated HCECs in inflammatory conditions treated with 100 µM FA and 1 µM KM (FA100/KM1) showed lower IL-1B , IL-6 , IL-8 , and TNFα expression when examined by real-time PCR. The BS with FA100/KM1 had neutral pH, and a similar osmolality and refractive index to human tears. Topical delivery of BS + FA100/KM1 showed no irritation to rabbit eyes. The corneal thickness in the BS + FA100/KM1 treated group was comparable to normal eyes. Results of DES rabbits treated with BS + FA100/KM1 showed less corneal epithelial damage and higher tear volume than the normal group. In conclusion, we showed that the combination of FA (100 µM) and KM (1 µM) towards treating inflamed HCECs had an anti-inflammatory effect, and it is effective in treating DES rabbits when BS is added in combination with these two herbal supplements and used as a topical eye drop.
Cumulative irritation potential of topical retinoid formulations.
Leyden, James J; Grossman, Rachel; Nighland, Marge
2008-08-01
Localized irritation can limit treatment success with topical retinoids such as tretinoin and adapalene. The factors that influence irritant reactions have been shown to include individual skin sensitivity, the particular retinoid and concentration used, and the vehicle formulation. To compare the cutaneous tolerability of tretinoin 0.04% microsphere gel (TMG) with that of adapalene 0.3% gel and a standard tretinoin 0.025% cream. The results of 2 randomized, investigator-blinded studies of 2 to 3 weeks' duration, which utilized a split-face method to compare cumulative irritation scores induced by topical retinoids in subjects with healthy skin, were combined. Study 1 compared TMG 0.04% with adapalene 0.3% gel over 2 weeks, while study 2 compared TMG 0.04% with tretinoin 0.025% cream over 3 weeks. In study 1, TMG 0.04% was associated with significantly lower cumulative scores for erythema, dryness, and burning/stinging than adapalene 0.3% gel. However, in study 2, there were no significant differences in cumulative irritation scores between TMG 0.04% and tretinoin 0.025% cream. Measurements of erythema by a chromameter showed no significant differences between the test formulations in either study. Cutaneous tolerance of TMG 0.04% on the face was superior to that of adapalene 0.3% gel and similar to that of a standard tretinoin cream containing a lower concentration of the drug (0.025%).
Wang, Xia-Rong; Gao, Si-Qian; Niu, Xiao-Qian; Li, Long-Jian; Ying, Xiao-Ying; Hu, Zhong-Jie; Gao, Jian-Qing
2017-01-01
Capsaicin has been used in clinical applications for the treatment of pain disorders and inflammatory diseases. Given the strong pungency and high oil/water partition coefficient of capsaicin, capsaicin-loaded nanolipoidal carriers (NLCs) were designed to increase permeation and achieve the analgesic, anti-inflammatory effect with lower skin irritation. Capsaicin-loaded NLCs were prepared and later optimized by the Box-Behnken design. The physicochemical characterizations, morphology, and encapsulation of the capsaicin-loaded NLCs were subsequently confirmed. Capsaicin-loaded NLCs and capsaicin-loaded NLCs gel exhibited sustained release and no cytotoxicity properties. Also, they could significantly enhance the penetration amount, permeation flux, and skin retention amounts of capsaicin due to the application of NLCs. To study the topical permeation mechanism of capsaicin, 3,3'-dioctadecyloxacarbocyanine perchlorate (Dio) was used as a fluorescent dye. Dio-loaded NLCs and Dio-loaded NLCs gel could effectively deliver Dio up to a skin depth of 260 and 210 μm, respectively, primarily through the appendage route on the basis of version skin sections compared with Dio solution, which only delivered Dio up to 150 μm. In vivo therapeutic experiments demonstrated that capsaicin-loaded NLCs and capsaicin-loaded NLCs gel could improve the pain threshold in a dose-dependent manner and inhibit inflammation, primarily by reducing the prostaglandin E2 levels in the tissue compared with capsaicin cream and capsaicin solution. Meanwhile, skin irritation was reduced, indicating that application of NLCs could decrease the irritation caused by capsaicin. Overall, NLCs may be a potential carrier for topical delivery of capsaicin for useful pain and inflammation therapy.
Kieć-Świcrczyńska, Marta; Chomiczewska-Skóra, Dorota; Świerczyńska-Machura, Dominika; Kręcisz, Beata
2014-01-01
Nurses are prone to develop hand eczema due to occupational exposure to irritants, including wet work. The aim of the study was to evaluate the impact of wet work on selected skin properties, reflecting epidermal barrier function--transepidermal water loss (TEWL) and stratum corneum hydration--and additionally skin viscoelasticity, in nurses. Study subjects included 90 nurses employed in hospital wards. Measurements were carried out within the dorsal aspect of the dominant hand, using a Cutometer MPA 580 equipped with Tewameter TM 300 and Corneometer CM 825 (Courage & Khazaka, Germany) probes. Examina- tions took place on hospital premises. Similar measurements were performed in the control group of females non-exposed to irritants. In the examined group of nurses, mean TEWL was 15.5 g/h/m2 and was higher than in the control group (12.99 g/h/m2). After rejecting the extreme results, the difference between the groups proved to be statistically significant (p < 0.05). The mean value of stratum corneum hydration was lower in the examined group (37.915) compared with the control group (40.05), but the difference was not sta tistically significant. Also results of viscoelasticity assessment showed no significant differences between studied groups. The results of the assessment of skin biophysical properties show that wet work exerts a moderately adverse impact on skin condition. A higher TEWL value and a lower stratum corneum hydration in workers exposed to irritants reflect an adverse impact of these factors on the epidermal barrier function.
Dicationic Alkylammonium Bromide Gemini Surfactants. Membrane Perturbation and Skin Irritation
Almeida, João A. S.; Faneca, Henrique; Carvalho, Rui A.; Marques, Eduardo F.; Pais, Alberto A. C. C.
2011-01-01
Dicationic alkylammonium bromide gemini surfactants represent a class of amphiphiles potentially effective as skin permeation enhancers. However, only a limited number of studies has been dedicated to the evaluation of the respective cytotoxicity, and none directed to skin irritation endpoints. Supported on a cell viability study, the cytotoxicity of gemini surfactants of variable tail and spacer length was assessed. For this purpose, keratinocyte cells from human skin (NCTC 2544 cell line), frequently used as a model for skin irritation, were employed. The impact of the different gemini surfactants on the permeability and morphology of model vesicles was additionally investigated by measuring the leakage of calcein fluorescent dye and analyzing the NMR spectra of 31P, respectively. Detail on the interaction of gemini molecules with model membranes was also provided by a systematic differential scanning calorimetry (DSC) and molecular dynamics (MD) simulation. An irreversible impact on the viability of the NCTC 2544 cell line was observed for gemini concentrations higher than 25 mM, while no cytotoxicity was found for any of the surfactants in a concentration range up to 10 mM. A higher cytotoxicity was also found for gemini surfactants presenting longer spacer and shorter tails. The same trend was obtained in the calorimetric and permeability studies, with the gemini of longest spacer promoting the highest degree of membrane destabilization. Additional structural and dynamical characterization of the various systems, obtained by 31P NMR and MD, provide some insight on the relationship between the architecture of gemini surfactants and the respective perturbation mechanism. PMID:22102870
Verstraelen, Sandra; Van Rompay, An R
2018-06-01
The main objective of the CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project (2015-2016) was to develop tiered, non-animal testing strategies for serious eye damage and eye irritation assessment in relation to the most important drivers of classification. The serious eye damage and eye irritation potential of a set of 80 chemicals was identified based on existing in vivo Draize eye test data and testing was conducted using the following eight alternative test methods: BCOP (Bovine Corneal Opacity and Permeability)+histopathology, BCOP-LLBO (BCOP Laser Light-Based Opacitometer), ICE (Isolated Chicken Eye)+histopathology, STE (Short Term Exposure), EpiOcular™ EIT (EpiOcular Eye Irritation Test), EpiOcular™ ET-50 (EpiOcular™ Time-to-toxicity), SkinEthic™ HCE EIT (SkinEthic™ Human Corneal Epithelial Eye Irritation Test), and SMI (Slug Mucosal Irritation). Project management decided to not include the ICE data in this project since the execution showed relevant, and not predictable, deviations from Organisation for Economic Co-operation and Development (OECD) Test Guideline (TG) 438 and Guidance Document 160. At this stage, the outcome of these deviations has not been fully assessed. In addition to these alternative test methods, the computational models Toxtree and Case Ultra were taken into account. This project assessed the relevance of these test methods, their applicability domains and limitations in terms of 'drivers of classification', and their strengths and weaknesses. In this way, methods were identified that fit into a tiered-testing strategy for serious eye damage/eye irritation assessment to distinguish United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS) Category 1 (Cat 1) chemicals from non-Cat 1 chemicals and address the gap namely distinguish between Category 2 (Cat 2) and Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cutaneous irritancy of an ibuprofen medicated plaster in healthy volunteers.
Maganji, Manisha; Connolly, Mark P; Bhatt, Aomesh
2018-04-01
To assess the irritation and contact sensitization potential of a 200 mg ibuprofen medicated plaster. This double-blind, phase-1 placebo controlled study had two phases; the induction phase to evaluate the irritant potential of continuous application of the plaster, and the challenge phase to assess contact sensitivity (allergy). The cumulative irritancy potential was evaluated using an adaptation of the Shelanski method. Healthy adults (≥18 years of age) (N = 210) were treated simultaneously with one ibuprofen medicated and one placebo plaster applied in a randomized fashion to either the left or right side of the lower back. During the induction phase, plasters were applied on Days 1, 3, 5, 8, 10, 12, 15, 17, and 19 and the final plaster removed on Day 22. At each scheduled visit plasters and applications sites were assessed for degree of adhesion and skin irritation (score of 1 = no irritation to 7 = strong reaction spreading beyond test sites), respectively. The challenge phase followed a two-week washout period. A plaster was applied on Day 36 for 48 h and assessment occurred on Days 38, 39, and 40. The mean cumulative irritation score during the induction phase was lower for the ibuprofen medicated plaster than the placebo plaster (0.32 vs. 1.23, respectively). Three (1.4%) subjects experience a dermal reaction of grade ≥3 for the ibuprofen medicated plaster compared with 27 (12.7%) for the placebo plaster. Following challenge with ibuprofen or placebo plasters, 12 subjects (6.2%) with the ibuprofen medicated plaster and four (2.2%) with the placebo plaster had skin reaction of assessment grade higher than the induction phase. One subject for the ibuprofen and two for the placebo plaster had reactions with grade >2. No subjects showed an increase in sensitization on Day 39 or 40 compared with Day 38. The findings indicate that the both the irritancy and contact sensitization of the ibuprofen medicated plaster is acceptable.
Angelova-Fischer, Irena; Hoek, Anne-Karin; Dapic, Irena; Jakasa, Ivone; Kezic, Sanja; Fischer, Tobias W; Zillikens, Detlef
2015-12-01
Fruit-derived organic compounds and detergents are relevant exposure factors for occupational contact dermatitis in the food industry. Although individuals with atopic dermatitis (AD) are at risk for development of occupational contact dermatitis, there have been no controlled studies on the effects of repeated exposure to multiple irritants, relevant for the food industry, in atopic skin. The aim of the study was to investigate the outcomes of repeated exposure to a fruit-derived organic acid and a detergent in AD compared to healthy volunteers. The volunteers were exposed to 2.0% acetic acid (AcA) and/or 0.5% sodium lauryl sulfate (SLS) in controlled tandem repeated irritation test. The outcomes were assessed by measurements of erythema, transepidermal water loss (TEWL) and natural moisturizing factor (NMF) levels. In the AD volunteers, repeated AcA exposure led to barrier disruption and significant TEWL increase; no significant differences after the same exposure in the healthy controls were found. Repeated exposure to SLS and the irritant tandems enhanced the reactions and resulted in a significantly higher increase in TEWL in the AD compared to the control group. Cumulative irritant exposure reduced the NMF levels in both groups. Differences in the severity of irritant-induced barrier impairment in atopic individuals contribute to the risk for occupational contact dermatitis in result of multiple exposures to food-derived irritants and detergents. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Skin Health Connected to the Use of Absorbent Hygiene Products: A Review.
Bender, Johanna Karlsson; Faergemann, Jan; Sköld, Maria
2017-09-01
Over the past 50 years, absorbent hygiene products such as baby diapers and incontinence products have become essential features of modern day life. Through innovation and enhanced technology, their design, composition and performance have been dramatically upgraded from their early forms, and they have transformed the lives of millions of people, improving their quality of life. Skin health related to the use of absorbent hygiene products has accordingly also greatly improved. Still, the wearing of absorbent hygiene products will affect the skin, and for some users the changes in microclimate, mechanical interactions and the exposure to urine and faeces may result in irritant contact dermatitis, i.e. diaper dermatitis (DD) or incontinence-associated dermatitis (IAD). Babies with developing skin and the elderly with deteriorating skin functions who are the most frequent users of absorbent hygiene products are more vulnerable to the causal factors. Although irritant reactions are the most common, allergic contact dermatitis should be considered if a DD/IAD fails to improve by recommended actions. There is also a connection between IAD and pressure ulcer development of which it is important to be aware. A holistic approach of using high-quality absorbent hygiene products in combination with appropriate skin care will help maintaining good skin health.
Segers, Kurt; Cytryn, Ephraim; Surquin, Murielle
2012-06-01
This retrospective study aimed to evaluate the incidence of transdermal rivastigmine treatment withdrawal secondary to adverse skin reactions among the patients from our Memory Clinic. In addition, we tested whether climatic conditions might have an influence on skin irritations leading to eventual treatment disruption. We performed a retrospective review of patients from the Brugmann University Hospital Memory Clinic having started transdermal rivastigmine between June 2008 and December 2010. Local meteorological data were provided by the Royal Meteorological Institute of Belgium. A total of 26.9% of the patients experienced adverse skin reactions at the rivastigmine application site, leading to treatment discontinuation in 19.2% of the cases. Rivastigmine cutaneous tolerability was not found to be related to demographic parameters, Mini Mental Status Examination score, or type of dementia. High temperature and low air humidity during the first month of treatment were found to be associated with a higher incidence of skin reactions and secondary treatment disruption. Transdermal rivastigmine induced a higher incidence of cutaneous adverse events than previously reported in a prospective clinical trial. Moreover, it seems that meteorological conditions favoring skin perspiration (high temperature and low air humidity) during the first month of treatment might have an influence on transdermal rivastigmine skin tolerability.
Wu, Dan; Katsumi, Hidemasa; Quan, Ying-Shu; Kamiyama, Fumio; Kusamori, Kosuke; Sakane, Toshiyasu; Yamamoto, Akira
2016-09-01
Available formulations of sumatriptan succinate (SS) have low bioavailability or are associated with site reactions. We developed various types of self-dissolving microneedle arrays (MNs) fabricated from sodium hyaluronate as a new delivery system for SS and evaluated their skin permeation and irritation in terms of clinical application. In vitro permeation studies with human skin, physicochemical properties (needle length, thickness and density), and penetration enhancers (glycerin, sodium dodecyl sulfate and lauric acid diethanolamide) were investigated. SS-loaded high-density MNs of 800 µm in length were the optimal formulation and met clinical therapeutic requirements. Penetration enhancers did not significantly affect permeation of SS from MNs. Optical coherence tomography images demonstrated that SS-loaded high-density MNs (800 µm) uniformly created drug permeation pathways for the delivery of SS into the skin. SS-loaded high-density MNs induced moderate primary skin irritations in rats, but the skin recovered within 72 h of removal of the MNs. These findings suggest that high-density MNs of 800 µm in length are an effective and promising formulation for transdermal delivery of SS. To our knowledge, this is the first report of SS permeation across human skin using self-dissolving MNs.
Zhang, Wenli; Wang, Guangji; See, Esther; Shaw, John P; Baguley, Bruce C; Liu, Jianping; Amirapu, Satya; Wu, Zimei
2015-04-10
The ultimate aim of this study was to develop asulacrine (ASL)-loaded long-circulating liposomes to prevent phlebitis during intravenous (i.v.) infusion for chemotherapy. Poly(ethylene)glycol (PEG) and poloxamer 188-modified liposomes (ASL-PEGL and ASL-P188L) were developed, and ASL was loaded using a remote loading method facilitated with a low concentration of sulfobutyl ether-β-cyclodextrin as a drug solubilizer. The liposomes were characterized in terms of morphology, size, release properties and stability. Pharmacokinetics and venous tissue tolerance of the formulations were simultaneously studied in rabbits following one-hour i.v. infusion via the ear vein. The irritancy was assessed using a rat paw-lift/lick model after subplantar injections. High drug loading 9.0% w/w was achieved with no drug leakage found from ASL-PEGL or ASL-P188L suspended in a 5% glucose solution at 30days. However, a rapid release (leakage) from ASL-PEGL was observed when PBS was used as release medium, partially related to the use of cyclodextrin in drug loading. Post-insertion of poloxamer 188 to the liposomes appeared to be able to restore the drug retention possibly by increasing the packing density of phospholipids in the membrane. In rabbits (n=5), ASL-P188L had a prolonged half-life with no drug precipitation or inflammation in the rabbit ear vein in contrast to ASL solution. Following subplantar (footpad) injections in rats ASL solution induced paw-lick/lift responses in all rats whereas ASL-P188L caused no response (n=8). PEGylation showed less benefit possibly due to the drug 'leakage'. In conclusion, drug precipitation in the vein and the drug mild irritancy may both contribute to the occurrence of phlebitis caused by the ASL solution, and could both be prevented by encapsulation of the drug in liposomes. Poloxamer 188 appeared to be able to 'seal' the liposomal membrane and enhance drug retention. The study also highlighted the importance of bio-relevant in vitro release study in formulation screening. Copyright © 2015. Published by Elsevier B.V.
Effect of piracetam and nimodipine on full-thickness skin burns in rabbits.
Sari, Elif; Dincel, Gungor C
2016-08-01
The potential of several drugs for full-thickness skin burns has been investigated, but the treatment of such burns remains a challenge in plastic surgery. The present study was designed to determine the effect of systemic and topical administration of piracetam and nimodipine on full-thickness skin burn wound healing. A total of 36 New Zealand male rabbits were divided into six groups. Full-thickness skin burns were produced in all the groups, except the control group. Piracetam was administered systemically (piracetam-IV) and topically (piracetam-C) for 14 days, and nimodipine was administered systemically (nimodipine-IV) and topically (nimodipine-C) over the burn wounds for 14 days. The sham group underwent burn injury but was not administered any drug. After 21 days, gross examination and histopathological analysis were performed and the results were compared statistically. Nimodipine-C and nimodipine-IV had no effect on burn wound healing. However, both piracetam-IV and piracetam-C significantly enhanced the healing of the full-thickness skin burn wounds, although the latter was more effective, useful and practical in burn wound healing. The histopathological features of the wounds in the piracetam-C group were closer to those of the control group than those of the other groups. Piracetam-C rather than piracetam-IV may promote full-thickness burn wound healing in rabbits. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Li, Sheng; Chen, Fei; Shen, Lujun; Zeng, Qi; Wu, Peihong
2016-08-05
To study the safety, feasibility and skin effects of irreversible electroporation (IRE) for breast tissue and breast cancer in animal models. Eight pigs were used in this study. IRE was performed on the left breasts of the pigs with different skin-electrode distances, and the right breasts were used as controls. The electrodes were placed 1-8 mm away from the skin, with an electrode spacing of 1.5-2 cm. Imaging and pathological examinations were performed at specific time points for follow-up evaluation. Vital signs, skin damage, breast tissue changes and ablation efficacy were also closely observed. Eight rabbit models with or without VX2 breast tumor implantations were used to further assess the damage caused by and the repair of thin skin after IRE treatment for breast cancer. Contrast-enhanced ultrasound and elastosonography were used to investigate ablation efficacy and safety. During IRE, the color of the pig breast skin reversibly changed. When the skin-electrode distance was 3 mm, the breast skin clearly changed, becoming white in the center and purple in the surrounding region during IRE. One small purulent skin lesion was detected several days after IRE. When the skin-electrode distance was 5-8 mm, the breast skin became red during IRE. However, the skin architecture was normal when evaluated using gross pathology and hematoxylin-eosin staining. When the skin-electrode distance was 1 mm, skin atrophy and yellow glabrescence occurred in the rabbit breasts after IRE. When the skin-electrode distance was ≥5 mm, there was no skin damage in the rabbit model regardless of breast cancer implantation. After IRE, complete ablation of the targeted breast tissue or cancer was confirmed, and apoptosis was detected in the target tissue and outermost epidermal layer. In the ablated breasts of the surviving animals, complete mammary regeneration with normal skin and hair was observed. Furthermore, no massive fibrosis or mass formation were detected on ultrasound or through hematoxylin-eosin staining. After IRE, the skin architecture was well preserved when the skin-electrode distance was ≥5 mm. Moreover, breast regeneration occurred without mass formation or obvious fibrosis.
Assessing occupational exposure to sea lamprey pesticides
Ceballos, Diana M; Beaucham, Catherine C; Kurtz, Kristine; Musolin, Kristin
2015-01-01
Background: Sea lampreys are parasitic fish found in lakes of the United States and Canada. Sea lamprey is controlled through manual application of the pesticides 3-trifluoromethyl-4-nitrophenol (TFM) and BayluscideTM into streams and tributaries. 3-Trifluoromethyl-4-nitrophenol may cause irritation and central nervous system depression and Bayluscide may cause irritation, dermatitis, blisters, cracking, edema, and allergic skin reactions. Objectives: To assess occupational exposures to sea lamprey pesticides. Methods: We developed a wipe method for evaluating surface and skin contamination with these pesticides. This method was field tested at a biological field station and at a pesticide river application. We also evaluated exposures using control banding tools. Results: We verified TFM surface contamination at the biological station. At the river application, we found surfaces and worker’s skin contaminated with pesticides. Conclusion: We recommended minimizing exposures by implementing engineering controls and improved use of personal protective equipment. PMID:25730600
Skin diseases during floods in Thailand.
Vachiramon, Vasanop; Busaracome, Ploysyne; Chongtrakool, Piriyaporn; Puavilai, Siripen
2008-04-01
Floods are natural disasters that occur occasionally in Thailand. The most common form skin diseases due to floods are infectious dermatoses especially superficial fungal infection. However the microbiologic evidences have not been evaluated. To evaluate the most common skin diseases during floods and identify the organism that causes skin maceration at web space(s) of toes (Hong Kong foot). Patients who complained of skin problems were evaluated at the temporary outpatient clinic during October 2006. Skin specimens from all patients who had itches and skin maceration at web space(s) of toes were cultured. Ninety-six patients were evaluated (38 males and 58 females). Eczema was the most prevalent dermatosis, which accounted for 34.5% of the total skin problems and the great majority of these cases were irritant contact dermatitis. Sixteen cases presented with itch and skin maceration at web space(s) of toes. All of them were colonized with various microorganisms. Gram-negative bacilli were the most prevalent ones and were found in 14 out of 16 specimens. Fungal culture was positive in only two specimens. Eczema is the most common dermatosis during floods. Skin maceration at web space(s) of toes, which were thought to be fungal infection, are chronic irritant dermatitis with secondary bacterial colonization. Only a few cases were fungal infection. Microbiologic investigation should be done in these patients. Unfortunately, it is not practical in such a situation. Topical medications that have the combination of antiinflammatory, antibacterial and antifungal properties are the most suitable medications.
Hsieh, Pei-Wen; Chen, Wei-Yu; Aljuffali, Ibrahim A; Chen, Chun-Che; Fang, Jia-You
2013-01-01
Hydroquinone and tranexamic acids (TXA) are skin-lightening agents with a hydrophilic nature and low skin absorption. A high dose is needed for clinical use, resulting in a high incidence of skin irritation. Co-drugs formed by conjugating hydroquinone and TXA were synthesized and their in vitro and in vivo skin absorption characteristics were evaluated. The two synthesized co-drugs were 4-hydroxyphenyl 4-(aminomethyl)cyclohexanecarboxylate (HAC) and 1,4- phenylene bis(aminomethyl)cyclohexanecarboxylate (BAC). The co-drugs were chemically stable in aqueous solution, but rapidly degraded to the respective parent drug in esterases and skin homogenates. Compared to hydroquinone application, 7.2- and 2.4-fold increments in the hydroquinone skin deposition were obtained with the in vitro application of HAC and BAC. HAC and BAC led to 3- and 2-fold enhancements of equivalent TXA deposition compared to TXA administration. The in vivo experiment showed a further enhancement of co-drugs compared to the in vitro setup. The transdermal penetration of co-drugs, especially BAC, was much lower than that of hydroquinone and TXA. This indicated high-level skin targeting by the co-drugs. HAC and BAC revealed strong affinities for the viable epidermis/dermis. Hair follicles are important reservoirs for co-drug delivery. Daily administration of co-drugs to the skin did not generate irritation for up to 7 days. Both co-drugs are superior candidates for treating skin hyperpigmentation.
Mitsuishi, Mikio; Oshikata, Takafumi; Kumabe, Shino; Kobayashi, Azusa; Katoku, Koshiro; Kanno, Takeshi; Hamamura, Masao; Tsuchitani, Minoru
2014-01-01
We reevaluated histological slides of dorsal skin in control animals from past percutaneous dose toxicity studies using dogs, rabbits and rats to provide background data concerning histological changes related to preparation and application procedures and vehicles or embrocations of every variety. Acanthosis, dermal or perifollicular inflammatory cell infiltration in dogs; hyperkeratosis, acanthosis, dermal inflammatory cell infiltration or hemorrhage in rabbits; and acanthosis, dermal inflammatory cell infiltration, crust or foreign body granuloma in rats were present as procedure-related underlying histological changes in the control animals. Four mechanical acts, (1) rubbing with gauze to remove an administered substance for reapplication, (2) use of a taut bandage to avoid slipping from the application site, (3) peeling a patch off as a preparation procedure for reapplication, and (4) clipping or shaving, were considered to cause injury to the skin. The degree of influence of the various application procedures was found to be as follows: sham, lotion < cream < ointment and tape in dogs; untreated control, sham < lotion < tape and poultice in rabbits; and sham, sodium carboxymethylcellulose < olive oil and lotion < ointment and tape in rats. The degree of ointment influence on rabbits is equivocal. PMID:26023255
THE USE OF SILICONES TO PROTECT THE SKIN
Morrow, Grant
1954-01-01
Silicote® ointment was used as a protective covering for the skin in the treatment of 107 patients with various kinds of dermatologic disease. In 83 the disease was cured or effectively controlled. It was particularly effective in conditions caused or aggravated by water-soluble or oil-soluble irritants. PMID:13116024
40 CFR 721.1150 - Substituted polyglycidyl ben-zena-mine.
Code of Federal Regulations, 2014 CFR
2014-07-01
... found to cause cancer, reproductive effects, kidney and liver effects in laboratory animals, and allergic reactions in humans; that this substance is a severe skin and eye irritant; and that the use of.... They have also caused allergic reactions in humans. —Prevent all contact with skin, eyes, and clothing...
40 CFR 721.1150 - Substituted polyglycidyl ben-zena-mine.
Code of Federal Regulations, 2013 CFR
2013-07-01
... found to cause cancer, reproductive effects, kidney and liver effects in laboratory animals, and allergic reactions in humans; that this substance is a severe skin and eye irritant; and that the use of.... They have also caused allergic reactions in humans. —Prevent all contact with skin, eyes, and clothing...
40 CFR 721.1150 - Substituted polyglycidyl ben-zena-mine.
Code of Federal Regulations, 2012 CFR
2012-07-01
... found to cause cancer, reproductive effects, kidney and liver effects in laboratory animals, and allergic reactions in humans; that this substance is a severe skin and eye irritant; and that the use of.... They have also caused allergic reactions in humans. —Prevent all contact with skin, eyes, and clothing...
Occupational skin diseases in Czech healthcare workers from 1997 to 2009.
Machovcová, A; Fenclová, Z; Pelclová, D
2013-04-01
The healthcare sector ranked in second place among economic sectors in the Czech Republic, with about 11.4 % of all occupational diseases in 2009. Skin diseases constituted about 20 % of all occupational diseases. The aim of this study was to analyze the causes and trends in allergic and irritant-induced skin diseases in the healthcare sector. The data concerning occupational skin diseases (Chapter IV of the Czech List of Occupational Diseases, non-infectious skin illnesses) in the healthcare sector were analyzed from the Czech National Registry of Occupational Diseases from 1997 until 2009. The trends in the total counts and most frequent causes were evaluated. During the past 13 years, a total of 545 skin diseases were acknowledged in healthcare workers. Allergic contact dermatitis was diagnosed in 464 (85 %), irritant contact dermatitis in 71 (13 %) and contact urticaria in 10 subjects (2 %). Ninety-five percent of the patients were females. The overall incidence in individual years varied between 1.0 and 2.9 cases per 10,000 full-time employees per year. Disinfectants were the most frequent chemical agents causing more than one third of all allergic skin diseases (38 %), followed by rubber components (32 %) and cleaning agents (10 %). A general downward trend of diagnosed cases of occupational skin diseases in heath care workers in the Czech Republic over the past 13 years was demonstrated.
DaSilva, Sonia C; Sahu, Ravi P; Konger, Raymond L; Perkins, Susan M; Kaplan, Mark H; Travers, Jeffrey B
2012-01-01
Atopic dermatitis (AD) is a pruritic, chronic inflammatory skin disease that affects 10-20% of children and 1-3% of adults worldwide. Recent studies have indicated that the ability of Th2 cytokines, such as interleukin-4 (IL-4) to regulate skin barrier function may be a predisposing factor for AD development. The present studies examined the ability of increased Th2 activity to affect cutaneous barrier function in vivo and epidermal thickening. Mice that express a constitutively active Signal Transducer and Activator of Transcription 6 (STAT6VT) have increased Th2 cells and a predisposition to allergic inflammation were used in these studies, they demonstrate that topical treatment with the irritant sodium lauryl sulfate (SLS) caused increased transepidermal water loss and epidermal thickening in STAT6VT mice over similarly treated wild-type mice. The proliferation marker Ki-67 was increased in the epidermis of STAT6VT compared to the wild-type mice. However, these differences do not appear to be linked to the addition of an irritant as control-treated STAT6VT skin also exhibited elevated Ki-67 levels, suggesting that the increased epidermal thickness in SLS-treated STAT6VT mice is primarily driven by epidermal cell hypertrophy rather than an increase in cellular proliferation. Our results suggest that an environment with increased Th2 cytokines results in abnormal responses to topical irritants.
DaSilva, Sonia C.; Sahu, Ravi P.; Konger, Raymond L.; Perkins, Susan M.; Kaplan, Mark H.; Travers, Jeffrey B.
2011-01-01
Atopic dermatitis (AD) is a pruritic, chronic inflammatory skin disease that affects 10–20% of children and 1–3% of adults worldwide. Recent studies have indicated that the ability of Th2 cytokines such as interleukin-4 (IL-4) to regulate skin barrier function may be a predisposing factor for AD development. The present studies examined the ability of increased Th2 activity to affect cutaneous barrier function in vivo and epidermal thickening. Mice that express a constitutively active Signal Transducer and Activator of Transcription 6 (STAT6VT) have increased Th2 cells and a predisposition to allergic inflammation were used in these studies; they demonstrate that topical treatment with the irritant sodium lauryl sulfate (SLS) caused increased transepidermal water loss and epidermal thickening in STAT6VT mice over similarly treated wild-type mice. The proliferation marker Ki-67 was increased in the epidermis of STAT6VT compared to wild-type mice. However, these differences do not appear to be linked to the addition of an irritant as control-treated STAT6VT skin also exhibited elevated Ki-67 levels, suggesting that the increased epidermal thickness in SLS-treated STAT6VT mice is primarily driven by epidermal cell hypertrophy rather than an increase in cellular proliferation. Our results suggest that an environment with increased Th2 cytokines results in abnormal responses to topical irritants. PMID:21959772
Influence of an antiperspirant on foot blister incidence during cross-country hiking.
Knapik, J J; Reynolds, K; Barson, J
1998-08-01
Rubbing moist skin results in higher frictional forces than rubbing very dry skin. As friction increases, the probability of activity-related blisters also increases. Therefore reducing moisture may reduce blister incidence during physical activity. We examined whether an antiperspirant can reduce foot blisters during hiking. In a double-blind study, cadets attending the US Military Academy were separated into two groups that used either an antiperspirant (20% aluminum chloride hexahydrate in anhydrous ethyl alcohol) or placebo (anhydrous ethyl alcohol) preparation. Cadets were told to apply preparations to their feet for 5 consecutive nights. On day 6, cadets completed a 21-km hike, and their feet were examined for blisters before and after. Because of dropouts, the final sample size was 667 cadets with 328 in the antiperspirant group and 339 in the placebo group. There was a high rate of noncompliance with the treatment schedule: Cadets used the preparations from 0 to 5 nights before the hike. For cadets using the preparations at least 3 nights before the hike (n=269), the incidence of foot blisters was 21% for the antiperspirant group and 48% for the placebo group (P < 0.01). However, reports of skin irritation were 57% for the antiperspirant group and 6% for the placebo group (P < 0.01). A 20% solution of aluminum chloride hexahydrate in anhydrous ethyl alcohol may be effective in reducing foot blisters during hiking; however, the side effect of skin irritation should be considered and preventive measures studied to reduce this irritation.
Successful treatment of sebaceous adenitis in a rabbit with ciclosporin and triglycerides.
Jassies-van der Lee, Annette; van Zeeland, Yvonne; Kik, Marja; Schoemaker, Nico
2009-02-01
A 4-year-old rabbit was presented with a chronic exfoliative dermatitis and patchy alopecia. General physical examination revealed no abnormalities. Skin scrapings and fungal culture were negative. A blood sample was obtained for a complete blood cell count and biochemical profile, and yielded results that were within normal limits. Radiographic examination of the thorax excluded the presence of a thymoma. Histopathology of the skin showed orthokeratotic hyperkeratosis, absence of sebaceous glands and mural lymphocytic folliculitis, consistent with sebaceous adenitis. Oral treatment was started with ciclosporin dissolved in a medium-chain triglyceride solution (Miglyol 812), combined with essential fatty acids and topical propylene glycol sprays. Within 2 months of treatment, complete regression of skin lesions and regrowth of hair was observed. Serum chemistry values including kidney and liver function tests remained within reference range during the course of treatment. Histopathological examination of control biopsies of the skin showed presence of normal sebaceous glands and active hair follicles. Treatment was changed to a different pharmaceutical formulation of ciclosporin without Miglyol and deterioration of clinical signs was noticed. Using pure Miglyol 812, however, resulted in a gradual improvement of 60%. A nearly complete response was again observed after re-administration of the combination ciclosporin/Miglyol. It is hypothesized that sebaceous adenitis in the rabbit is most likely due to an autoimmune reaction directed at the sebaceous glands and a defect in lipid metabolism. The outcome indicates that a combination of ciclosporin and Miglyol 812 is a promising new treatment for sebaceous adenitis in rabbits.
Shvartsbeyn, Marianna; Tuchinda, Papapit; Gaitens, Joanna; Squibb, Katherine S; McDiarmid, Melissa A; Gaspari, Anthony A
2011-01-01
The Depleted Uranium Follow-Up Program is a clinical surveillance program run by the Baltimore Veterans Affairs Medical Center since 1993 for veterans of the Gulf and Iraqi wars who were exposed to depleted uranium (DU) as a result of "friendly-fire" incidents. In 2009, 40 veterans from this cohort were screened for skin reactivity to metals by patch-testing with extended metal series and uranyl acetate (0.25%, 2.5%, and 25%). A control arm comprised 46 patients without any known occupational exposures to DU who were seen at the University of Maryland Dermatology Clinic for evaluation of allergic contact dermatitis. Excluding irritant reactions, no patch-test reactions to uranyl acetate were observed in the participants. Irritant reactions to DU were more common in the clinic cohort, likely reflective of the demographic differences between the two arms of the study. Biologic monitoring of urine uranium concentrations in the DU program participants with 24-hour urine samples showed evidence of percutaneous uranium absorption from the skin patches. We conclude that dermatitis observed in a subset of the veterans was unrelated to their military DU exposure. Our data suggest that future studies of skin testing with uranyl acetate should utilize 0.25%, the least irritating concentration.
Nasr, Maha; Abdel-Hamid, Sameh; Moftah, Noha H; Fadel, Maha; Alyoussef, Abdullah A
2017-01-01
Nanotechnology has provided substantial benefits in drug delivery, especially in the treatment of dermatological diseases. Psoriasis is a chronic inflammatory skin disease in which topical delivery of antipsoriatic agents is considered the first line treatment. To investigate whether the encapsulation of the synthetic retinoid tazarotene in a nanocarrier based on jojoba oil would decrease its irritation potential and clinically improve its therapeutic outcome in psoriatic patients. A microemulsion system based on jojoba wax and labrasol/plurol isostearique was prepared and characterized. The selected formula displayed spherical morphology, particle size of 15.49±2.41 nm, polydispersity index of 0.20 ±0.08, negative charge and low viscosity. The microemulsion provided two folds increase in skin deposition of tazarotene, correlating with higher reduction in psoriatic patients PASI scores after treatment (68% reduction in PASI scores versus 8.96% reduction with the marketed gel). No irritation was encountered in patients using microemulsion, with redness and inflammation reported with the marketed gel-treated patients. Jojoba oil microemulsion proved to be advantageous in reducing the irritancy of tazarotene, enhancing its skin deposition and achieving better therapeutic outcome in psoriatic patients. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Adriaens, E; Alépée, N; Kandarova, H; Drzewieckac, A; Gruszka, K; Guest, R; Willoughby, J A; Verstraelen, S; Van Rompay, A R
2017-10-01
Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. In the past, several prospective and retrospective validation studies have taken place in the area of serious eye damage/eye irritation testing. Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. A very important aspect to ensure development of successful alternative test methods and/or strategies for serious eye damage/eye irritation testing is the selection of appropriate reference chemicals. A set of 80 reference chemicals was selected for the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project, in collaboration with Cosmetics Europe, from the Draize Reference Database published by Cosmetics Europe based on key criteria that were set in their paper (e.g. balanced by important driver of classification and physical state). The most important goals of the CON4EI project were to identify the performance of eight in vitro alternative tests in terms of driver of classification and to identify similarities/differences between the methods in order the build a successful testing strategy that can discriminate between all UN GHS categories. This paper provides background on selection of the test chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.
Adriaens, E; Alépée, N; Kandarova, H; Drzewieckac, A; Gruszka, K; Guest, R; Willoughby, J A; Verstraelen, S; Van Rompay, A R
2018-06-01
Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. In the past, several prospective and retrospective validation studies have taken place in the area of serious eye damage/eye irritation testing. Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. A very important aspect to ensure development of successful alternative test methods and/or strategies for serious eye damage/eye irritation testing is the selection of appropriate reference chemicals. A set of 80 reference chemicals was selected for the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project, in collaboration with Cosmetics Europe, from the Draize Reference Database published by Cosmetics Europe based on key criteria that were set in their paper (e.g. balanced by important driver of classification and physical state). The most important goals of the CON4EI project were to identify the performance of eight in vitro alternative tests in terms of driver of classification and to identify similarities/differences between the methods in order the build a successful testing strategy that can discriminate between all UN GHS categories. This paper provides background on selection of the test chemicals. Copyright © 2018. Published by Elsevier Ltd.
Nanostructured lipid carriers for the topical delivery of tretinoin.
Ghate, Vivek M; Lewis, Shaila A; Prabhu, Prabhakara; Dubey, Akhilesh; Patel, Nilkumar
2016-11-01
Cosmetic skin care products currently in the market demonstrate an increasing trend toward antiaging products. Selection of the right formulation approach is the key to successful consumer acceptance. Nanostructured lipid carriers (NLCs) for dermal application can render added benefits to the formulation. Tretinoin a derivative of vitamin A, is a retinoid with anti-aging and anti-acne potential. The present study was aimed at formulating NLCs of tretinoin for reducing the skin irritation potential, increasing the drug loading capacity and prolonging the duration of action. The NLCs were optimized using the response surface methodology based on the particle size. Preliminary study, suggested the use of stearic acid, oleic acid, Tween 80 and Span 60 as solid lipid, liquid lipid and surfactants respectively formed a stable dispersion. NLCs of tretinoin were prepared by hot melt microemulsion and hot melt probe sonication methods. The properties of the optimized NLCs such as morphology, size, Zeta potential, stability and in vitro drug release were investigated. Tretinoin loaded NLCs in carbopol gel showed a sustained release pattern with isopropyl alcohol as the receptor fluid compared to the marketed gel using Franz diffusion cells. Eight prepared gel formulations tested were found to follow the Higuchi model of drug release. Stability studies indicated that the formulations stored at refrigeration and room temperature showed no noticeable differences in the drug content and release profiles in vitro, after a period of 4 weeks. In vivo skin irritation test on male Wister rats indicated no irritation or erythema after application of the NLCs loaded gel repeated for a period of 7 days compared to the application of marketed tretinoin gel which showed irritation and slight erythema within 3 days. The results showed that the irritation potential of tretinoin was reduced, the drug loading was increased and the drug release was prolonged by the incorporation into the NLCs. Copyright © 2016 Elsevier B.V. All rights reserved.
Bandier, J; Carlsen, B C; Rasmussen, M A; Petersen, L J; Johansen, J D
2015-06-01
Filaggrin is key for the integrity of the stratum corneum. Mutations in the filaggrin gene (FLGnull) play a prominent role in atopic dermatitis (AD) pathogenesis. People with AD have increased susceptibility to irritants. However, little is known about the effect of filaggrin genotype and AD phenotype on irritant response and skin regeneration. To investigate the role of FLGnull and AD groups for skin reaction and recovery after sodium lauryl sulfate (SLS) irritation. This is a case-control study comprising 67 subjects, including healthy controls and patients with and without FLGnull and AD. Reactivity to different doses of SLS at 24, 48, 72 and 145 h after SLS application was measured by transepidermal water loss (TEWL) and laser Doppler flowmetry (LDF). Reactivity was assessed univariately and by pattern analysis. All patient groups showed a higher degree of skin-barrier disruption and inflammation than did controls in response to SLS. Assessing reactivity by the delta value of the area under the curve for both TEWL and LDF showed significant differences between healthy controls and those with the AD phenotype, irrespective of filaggrin mutation. The poorest regeneration was among those with the AD phenotype. The two AD phenotype groups were separated by multivariate technique, due to earlier inflammatory reactivity among subjects with FLGnullplus AD compared with the AD phenotype alone. Both skin reaction and regeneration were significantly different between the patient population and the healthy controls. Additionally, response severity and regeneration depended more on AD phenotype than on filaggrin genotype, whereas the response was more rapid among the FLGnullplus AD individuals. © 2015 British Association of Dermatologists.
Highly efficient and compatible shampoo for use after hair transplant.
Schweiger, Dorothea; Schoelermann, Andrea M; Filbry, Alexander; Hamann, Tina; Moser, Claudia; Rippke, Frank
2015-01-01
Sensitive or hyperreactive skin is a common condition defined by prickling, burning, pain, and pruritus. Although this skin problem was initially described on the face, the scalp is often affected. A sensitive scalp can react with irritation to harsh surfactants or other additives which are often present in shampoos. For this reason, we developed a new rinse-off hypertolerant shampoo specifically designed for the hypersensitive and problematic scalp. The shampoo formulation is based on an extremely mild surfactant system and contains bisabolol, an anti-irritant and anti-inflammatory ingredient of chamomile. The shampoo is free of additives such as perfumes, silicones, colorants, parabens, paraffins, and betaine. Since skin can remain in a hyperreactive state after wounding, the status after hair transplantation was chosen as a model system to test the shampoo. Scalp condition and compatibility of each volunteer were analyzed by a plastic surgeon directly after hair transplant and after stitch removal. The plastic surgeons also rated whether they would recommend the further use of the test shampoo. Additionally, volunteers completed a self-assessment questionnaire. Following hair transplantation, regular use of the shampoo resulted in a significant reduction in the extent of scabbing and erythema. This was confirmed by dermatological scalp examinations performed by the plastic surgeon as well as in volunteers' self-assessments. The plastic surgeon highly recommended the further use of the test shampoo after hair transplant to all study participants. Application of the test shampoo demonstrated excellent skin compatibility and product efficacy after hair transplant. The test shampoo significantly reduced the extent of scabs and erythema. Therefore, the shampoo is ideally suited for use after hair transplantation and for the treatment of sensitive scalp. The excellent skin compatibility is because of the mild surfactant system, the calming ingredient bisabolol, and the absence of potentially irritating ingredients.
2014-04-01
randomization design, after all patients are treated with dermal matrix, patients will be randomized to Arm 1 (control group; standard skin grafting with... grafts are often “meshed” or flattened and spread out to increase the size of the skin graft to better cover a large wound. Standard “meshing” increases...the size of the donor graft by 1.5 times (1:1.5). Problems with healing and skin irritation remain with such skin grafts when the injured areas are
Carvalho, André Luis Menezes; Silva, José Alexsandro da; Lira, Ana Amélia Moreira; Conceição, Tamara Matos Freire; Nunes, Rogéria de Souza; de Albuquerque Junior, Ricardo Luiz Cavalcanti; Sarmento, Victor Hugo Vitorino; Leal, Leila Bastos; de Santana, Davi Pereira
2016-07-01
This study proposed to investigate and to compare colloidal carrier systems containing Zidovudine (3'-azido-3'-deoxythymidine) (AZT) for transdermal administration and optimization of antiretroviral therapy. Microemulsion (ME) and lamellar phase (LP) liquid crystal were obtained and selected from pseudoternary diagrams previously developed. Small-angle X-ray scattering and rheology analysis confirmed the presence of typical ME and liquid crystalline structures with lamellar arrangement, respectively. Both colloidal carrier systems, ME, and LP remained stable, homogeneous, and isotropic after AZT addition. In vitro permeation study (using pig ear skin) showed that the amount of permeated drug was higher for ME compared to the control and LP, obtaining a permeation enhancing effect on the order of approximately 2-fold (p < 0.05). Microscopic examination after in vivo skin irritation studies using mice suggested few histological changes in the skin of animals treated with the ME compared to the control group (hydrogel). Thus, ME proved to be adequate and have promising effects, being able to promote the drug permeation without causing apparent skin irritation. On the order hand, LP functioned as a drug reservoir reducing AZT partitioning into the skin. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Yu, Yi-Hsin; Lu, Shao-Wei; Liao, Lun-De; Lin, Chin-Teng
2014-01-01
Many commercially available electroencephalography (EEG) sensors, including conventional wet and dry sensors, can cause skin irritation and user discomfort owing to the foreign material. The EEG products, especially sensors, highly prioritize the comfort level during devices wear. To overcome these drawbacks for EEG sensors, this paper designs Societe Generale de Surveillance S [Formula: see text] A [Formula: see text] (SGS)-certified, silicon-based dry-contact EEG sensors (SBDSs) for EEG signal measurements. According to the SGS testing report, SBDSs extract does not irritate skin or induce noncytotoxic effects on L929 cells according to ISO10993-5. The SBDS is also lightweight, flexible, and nonirritating to the skin, as well as capable of easily fitting to scalps without any skin preparation or use of a conductive gel. For forehead and hairy sites, EEG signals can be measured reliably with the designed SBDSs. In particular, for EEG signal measurements at hairy sites, the acicular and flexible design of SBDS can push the hair aside to achieve satisfactory scalp contact, as well as maintain low skin-electrode interface impedance. Results of this paper demonstrate that the proposed sensors perform well in the EEG measurements and are feasible for practical applications.
Quatresooz, Pascale; Piérard-Franchimont, Claudine; Piérard, Gérald E
2009-09-01
Sensitive/reactive skin is regarded as a manifestation of sensory irritation. This susceptibility condition to various exogenous factors suggests the intervention of some neuropeptides and other neurobiological mediators. Mast cells are among the putative implicated cells. The present immunohistochemical and morphometric study was performed on two groups of 36 gender- and age-matched subjects complaining or not from reactive skin as determined by electric current perception. In the mid upper part of the dermis, the numerical density in mast cells and the size of the microvasculature were assessed distinguishing the blood and lymphatic vessels. Globally, the distributions of data were large in reactive skin. This condition was characterized by a prominent increase in both the numerical density in mast cells and the overall size of the lymphatics. By contrast, no difference was found in the size of cutaneous blood vessels. More precisely, it appeared that a subgroup of people with reactive skin exhibited these changes contrasting with some other individuals whose data remained close to the normal range. Mast cells and lymphatics are probably involved in the process of sensory irritation affecting a subgroup of the population.
INFECTIOUS MYXOMATOSIS (SANARELLI) IN PREGNANT RABBITS
Sprunt, Douglas H.
1932-01-01
Pregnancy in rabbits alters the reactivity of the tissues to the virus of infectious myxomatosis. The livers of pregnant animals with the myxoma have a central acidophilic necrosis. Secondary lesions in the lungs are much more numerous and larger in the pregnant than in the non-gravid animals. In like manner the lesions in the spleen are more extensive in the pregnant rabbit. On the other hand the skin lesions of the pregnant animal are decreased in size. PMID:19870088
McNamee, Pauline; Hibatallah, Jalila; Costabel-Farkas, Margit; Goebel, Carsten; Araki, Daisuke; Dufour, Eric; Hewitt, Nicola J; Jones, Penny; Kirst, Annette; Le Varlet, Béatrice; Macfarlane, Martin; Marrec-Fairley, Monique; Rowland, Joanna; Schellauf, Florian; Scheel, Julia
2009-07-01
The need for alternative approaches to replace the in vivo rabbit Draize eye test for evaluation of eye irritation of cosmetic ingredients has been recognised by the cosmetics industry for many years. Extensive research has lead to the development of several assays, some of which have undergone formal validation. Even though, to date, no single in vitro assay has been validated as a full replacement for the rabbit Draize eye test, organotypic assays are accepted for specific and limited regulatory purposes. Although not formally validated, several other in vitro models have been used for over a decade by the cosmetics industry as valuable tools in a weight of evidence approach for the safety assessment of ingredients and finished products. In light of the deadlines established in the EU Cosmetics Directive for cessation of animal testing for cosmetic ingredients, a COLIPA scientific meeting was held in Brussels on 30th January, 2008 to review the use of alternative approaches and to set up a decision-tree approach for their integration into tiered testing strategies for hazard and safety assessment of cosmetic ingredients and their use in products. Furthermore, recommendations are given on how remaining data gaps and research needs can be addressed.
The Effect of Liquid Gun Propellant (LGP) on Skin.
1992-02-27
sodium lauryl sulfate ) decreased the barrier properties of hairless guinea pig skin to the greatest extent after I day, and the barrier returned to normal...San Francisco, CA. Wilhelm K.-P., Surber, C. and Maibach, H.I. Effect of sodium lauryl sulfate - induced skin irritation on in vivo percutaneous...NJ), followed by an intravenous injection of sodium pentobarbital (18 mg/kg, Anthony Products, Arcadia, CA). A Padgett Electro Dermatome (Padgett
Uzunova, S; Baĭnova, A; Iordanova, I; Dolova, D
1986-01-01
The new anti-flammable preparations, proposed by the Higher Chemical Technology Institute (Sofia), were studied, namely: Pyrofix 2--for treatment of textile materials and Torflam--for production of anti-inflammable polyester fibres. The following parameters were studied: skin-irritating and skin-sensitizing effect of both preparations, skin toxic effect of Pyrofix 2 and migration of chemicals from the anti-inflammable textile materials (from the composition of the preparations used). The results obtained revealed the absence of skin-irritating and skin-sensitizing effect of both preparations and cumulative dermal toxicity of Pyrofix 2. The textile materials with reduced combustibility are chemically stable and do not release compounds in the contact aqueous medium, imitating the underclothes space. Formaldehyde from recipe for the treatment of Pyrofix 2 migrates in the air environment. In conclusion, Pyrofix 2 could be applied for the final anti-inflammable treatment of the textile materials for industrial needs, working garments and everyday textile (with the elimination of formaldehyde compound from the recipe). Torflam could be used in the production of anti-inflammable polyester fibres for textile materials intended for industry and everyday life without immediate contact with the skin of the consumers.
Xu, Tingting; Xu, Xiaoyue; Gu, Yan; Fang, Lei; Cao, Feng
2018-01-01
To enhance ocular bioavailability, the traditional strategies have focused on prolonging precorneal retention and improving corneal permeability by nano-carriers with positive charge, thiolated polymer, absorption enhancer and so on. Glycylsarcosine (GS) as an active target ligand of the peptide tranpsporter-1 (PepT-1), could specific interact with the PepT-1 on the cornea and guide the nanoparticles to the treating site. The objective of the study was to explore the active targeting intercalated nanocomposites based on chitosan-glutathione-glycylsarcosine (CG-GS) and layered double hydroxides (LDH) as novel carriers for the treatment of mid-posterior diseases. CG-GS-LDH intercalated nanocomposites were prepared by the coprecipitation hydrothermal method. In vivo precorneal retention study, ex vivo fluorescence images, in vivo experiment for distribution and irritation were studied in rabbits. The cytotoxicity and cellular uptake were studied in human corneal epithelial primary cells (HCEpiC). CG-GS-LDH nanocomposites were prepared successfully and characterized by FTIR and XRD. Experiments with rabbits showed longer precorneal retention and higher distribution of fluorescence probe/model drug. In vitro cytological study, CG-GS-LDH nanocomposites exhibited enhanced cellular uptake compared to pure drug solution. Furthermore, the investigation of cellular uptake mechanisms demonstrated that both the active transport by PepT-1 and clathrin-mediated endocytosis were involved in the internalization of CG-GS-LDH intercalated nanocomposites. An ocular irritation study and a cytotoxicity test indicated that these nanocomposites produced no significant irritant effects. The active targeting intercalated nanocomposites could have great potential for topical ocular drug delivery due to the capacity for prolonging the retention on the ocular surface, enhancing the drug permeability through the cornea, and efficiently delivering the drug to the targeted site.
Gu, Yan
2018-01-01
Background To enhance ocular bioavailability, the traditional strategies have focused on prolonging precorneal retention and improving corneal permeability by nano-carriers with positive charge, thiolated polymer, absorption enhancer and so on. Glycylsarcosine (GS) as an active target ligand of the peptide tranpsporter-1 (PepT-1), could specific interact with the PepT-1 on the cornea and guide the nanoparticles to the treating site. Purpose The objective of the study was to explore the active targeting intercalated nanocomposites based on chitosan-glutathione-glycylsarcosine (CG-GS) and layered double hydroxides (LDH) as novel carriers for the treatment of mid-posterior diseases. Materials and methods CG-GS-LDH intercalated nanocomposites were prepared by the coprecipitation hydrothermal method. In vivo precorneal retention study, ex vivo fluorescence images, in vivo experiment for distribution and irritation were studied in rabbits. The cytotoxicity and cellular uptake were studied in human corneal epithelial primary cells (HCEpiC). Results CG-GS-LDH nanocomposites were prepared successfully and characterized by FTIR and XRD. Experiments with rabbits showed longer precorneal retention and higher distribution of fluorescence probe/model drug. In vitro cytological study, CG-GS-LDH nanocomposites exhibited enhanced cellular uptake compared to pure drug solution. Furthermore, the investigation of cellular uptake mechanisms demonstrated that both the active transport by PepT-1 and clathrin-mediated endocytosis were involved in the internalization of CG-GS-LDH intercalated nanocomposites. An ocular irritation study and a cytotoxicity test indicated that these nanocomposites produced no significant irritant effects. Conclusions The active targeting intercalated nanocomposites could have great potential for topical ocular drug delivery due to the capacity for prolonging the retention on the ocular surface, enhancing the drug permeability through the cornea, and efficiently delivering the drug to the targeted site. PMID:29491707
Topical Hazard Evaluation Program Procedural Guide.
1982-01-01
conditions and are percent (w/v) Oil of tion reaction under test not expected to cause a Bergamot solution conditions. photochemical irritation...photochemical skin irritant ( Bergamot oil). d. All compounds-are handled with caution. Current test procedures cannot eliminate the possibility of individual...percent ethyl alcohol. One additional compound applied along with the test compounds is a 10 percent solution (w/v) of Bergamot oil" in 95 percent ethyl
Alternatives to animal testing: research, trends, validation, regulatory acceptance.
Huggins, Jane
2003-01-01
Current trends and issues in the development of alternatives to the use of animals in biomedical experimentation are discussed in this position paper. Eight topics are considered and include refinement of acute toxicity assays; eye corrosion/irritation alternatives; skin corrosion/irritation alternatives; contact sensitization alternatives; developmental/reproductive testing alternatives; genetic engineering (transgenic) assays; toxicogenomics; and validation of alternative methods. The discussion of refinement of acute toxicity assays is focused primarily on developments with regard to reduction of the number of animals used in the LD(50) assay. However, the substitution of humane endpoints such as clinical signs of toxicity for lethality in these assays is also evaluated. Alternative assays for eye corrosion/irritation as well as those for skin corrosion/irritation are described with particular attention paid to the outcomes, both successful and unsuccessful, of several validation efforts. Alternative assays for contact sensitization and developmental/reproductive toxicity are presented as examples of methods designed for the examination of interactions between toxins and somewhat more complex physiological systems. Moreover, genetic engineering and toxicogenomics are discussed with an eye toward the future of biological experimentation in general. The implications of gene manipulation for research animals, specifically, are also examined. Finally, validation methods are investigated as to their effectiveness, or lack thereof, and suggestions for their standardization and improvement, as well as implementation are reviewed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alekseeva, O.G.
The experiments were staged on rabbits subjected to x ray irradiation (800 r). The adsorptive properties were studied with the cells of blood, liver, kidneys, spleen, small intestine, mesenteric ganglia, and muscles with respect to live culture oi Staphylococcus albus. In the irradiated rabbits the changes of adsorption were insignificant and they did not lead to the impairment of this protective function of the organism. The changes were most pronounced in the liver and were characterized by an increase of the adsorptive capacity. The introduction of penicillin for curative purposes to nonirradiated animals could provoke an inhibition of adsorptive propertiesmore » of tissues, whereas in the irradiated rabbits this inhibitory influence of penicillin was less distinct. Moreover in the first 3 days following irradiation it even activated the process. In the author's opinion, the intensification of adsorptive properties in the liver and kidneys upon the action of various irritants on the organism demonstrates the compensatory ability of the latter. (auth)« less
78 FR 17123 - Amitraz; Pesticide Tolerances
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-20
... inhalation routes of exposure. Further, it is not a skin or eye irritant, nor is it a skin sensitizer..., neurotoxic effects such as dry mouth, drowsiness, decreased temperature, and bradycardia were seen within 90... mg/ subjects. LOAEL = 0.25 mg/kg/day FQPA SF = UFDB = 10x kg/day. based on dry mouth, drowsiness...
van Triel, Jos J; van Bree, Bianca W J; Roberts, David W; Muijser, Hans; Duistermaat, Evert; Woutersen, Ruud A; Kuper, C Frieke
2011-01-11
Previously, a selection of low molecular weight contact and respiratory allergens had tested positive in both a skin and a respiratory local lymph node assay (LLNA), but formaldehyde was negative for sensitization by inhalation. To investigate whether this was due to intrinsic properties of aldehyde sensitizers, the structurally related allergen glutaraldehyde (GA) was tested. BALB/c mice were exposed by inhalation to 6 or 18ppm GA (respiratory LLNA), both generated as a vapor and as an aerosol. Other groups received 0.25% or 2.5% GA on the skin of the ears (skin LLNA). Lymphocyte proliferation and cytokine production were measured in the draining lymph nodes. GA was positive in the skin LLNA and its cytokine profile (IL-4/IFN-γ) skewed towards a Th2-type immune response with increasing dose. Inhalation exposure did not result in increased lymphocyte proliferation or increased cytokine levels, despite comparable tissue damage (irritation) in the skin and respiratory tract. We hypothesize that the highly reactive and hydrophilic GA oligomerizes in the protein-rich mucous layer of the respiratory tract, which impedes sensitization but still facilitates local irritation. Within the context of risk assessment in respiratory allergy, our results stress the importance of prevention of skin--besides inhalation-- exposure to aldehydes like GA. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Salinas, M L; Ogura, T; Soffchi, L
2001-02-01
It was found that needle-like calcium oxalate crystals, raphides, are found abundantly in all tissues of Agave tequilana plants; thus, 1 droplet (0.03 ml) of juice pressed from leaves contains 100-150 crystals, 30-500 microm in length, sharpened at both ends. In tequila distilleries, 5/6 of the workers who handle the agave stems have experienced the characteristic irritation. In contrast, only 1/3 of workers in agave plantations who harvest agave plants, complain of the irritation. It is confirmed that all the irritation suffered in both distilleries and plantations takes place at bodily locations where the plants come into contact with the worker's skin in the course of their work.
Verma, Rajeshwar P; Matthews, Edwin J
2015-03-01
Evaluation of potential chemical-induced eye injury through irritation and corrosion is required to ensure occupational and consumer safety for industrial, household and cosmetic ingredient chemicals. The historical method for evaluating eye irritant and corrosion potential of chemicals is the rabbit Draize test. However, the Draize test is controversial and its use is diminishing - the EU 7th Amendment to the Cosmetic Directive (76/768/EEC) and recast Regulation now bans marketing of new cosmetics having animal testing of their ingredients and requires non-animal alternative tests for safety assessments. Thus, in silico and/or in vitro tests are advocated. QSAR models for eye irritation have been reported for several small (congeneric) data sets; however, large global models have not been described. This report describes FDA/CFSAN's development of 21 ANN c-QSAR models (QSAR-21) to predict eye irritation using the ADMET Predictor program and a diverse training data set of 2928 chemicals. The 21 models had external (20% test set) and internal validation and average training/verification/test set statistics were: 88/88/85(%) sensitivity and 82/82/82(%) specificity, respectively. The new method utilized multiple artificial neural network (ANN) molecular descriptor selection functionalities to maximize the applicability domain of the battery. The eye irritation models will be used to provide information to fill the critical data gaps for the safety assessment of cosmetic ingredient chemicals. Copyright © 2014 Elsevier Inc. All rights reserved.
Suh, Mina; Troese, Matthew J; Hall, Debra A; Yasso, Blair; Yzenas, John J; Proctor, Debora M
2014-12-01
Electric arc furnace (EAF) steel slag is alkaline (pH of ~11-12) and contains metals, most notably chromium and nickel, and thus has potential to cause dermal irritation and sensitization at sufficient dose. Dermal contact with EAF slag occurs in many occupational and environmental settings because it is used widely in construction and other industrial sectors for various applications including asphaltic paving, road bases, construction fill, and as feed for cement kilns construction. However, no published study has characterized the potential for dermal effects associated with EAF slag. To assess dermal irritation, corrosion and sensitizing potential of EAF slag, in vitro and in vivo dermal toxicity assays were conducted based on the Organisation for Economic Co-operation and Development (OECD) guidelines. In vitro dermal corrosion and irritation testing (OECD 431 and 439) of EAF slag was conducted using the reconstructed human epidermal (RHE) tissue model. In vivo dermal toxicity and delayed contact sensitization testing (OECD 404 and 406) were conducted in rabbits and guinea pigs, respectively. EAF slag was not corrosive and not irritating in any tests. The results of the delayed contact dermal sensitization test indicate that EAF slag is not a dermal sensitizer. These findings are supported by the observation that metals in EAF slag occur as oxides of low solubility with leachates that are well below toxicity characteristic leaching procedure (TCLP) limits. Based on these results and in accordance to the OECD guidelines, EAF slag is not considered a dermal sensitizer, corrosive or irritant. Copyright © 2014 John Wiley & Sons, Ltd.
Skin Color and Pigmentation in Ethnic Skin.
Visscher, Marty O
2017-02-01
Skin coloration is highly diverse, partly due to the presence of pigmentation. Color variation is related to the extent of ultraviolet radiation exposure, as well as other factors. Inherent skin coloration arises from differences in basal epidermal melanin amount and type. Skin color is influenced by both the quantity and distribution of melanocytes. The effectiveness of inherent pigmentation for protecting living cells also varies. This article discusses skin color, pigmentation, and ethnicity in relation to clinical practice. Color perception, skin typing/classification, and quantitation of pigmentation are reviewed in relation to ethnicity, environmental stresses/irritants, and potential treatment effects. Copyright © 2016 Elsevier Inc. All rights reserved.
Use of oral fluralaner for the treatment of Psoroptes cuniculi in 15 naturally infested rabbits.
Sheinberg, Galia; Romero, Camilo; Heredia, Rafael; Capulin, Miguel; Yarto, Enrique; Carpio, Juan
2017-08-01
Psoroptes cuniculi, a nonburrowing ear mite, is a common ectoparasite of rabbits. Constant irritation of the auditory canal by the presence of this mite can lead to otitis externa or otoacariasis. The goal of this study was to evaluate the effect of fluralaner on rabbits naturally infested with P. cuniculi and exhibiting clinical signs. Fifteen female New Zealand domestic rabbits with otitis due to naturally occurring infestation with P. cuniculi. The external ears and ear canals of each individual were examined; samples of otic exudate were extracted with cotton swabs and examined microscopically for identification of the ectoparasite. Each animal was treated with a single 25 mg/kg oral dose of fluralaner. The amount of otic exudate/cerumen was assessed and samples were obtained from the ears to evaluate for presence or absence of mites at 4, 8, 12, 16, 20, 40 and 90 days after receiving treatment. Post-treatment, the amount of otic exudate decreased rapidly in all animals; by Day 12 and until the end of the study all rabbits were judged to have low amount of exudate with normally visible canals. The percentage of ears positive for P. cuniculi decreased to 13.3% of ears sampled by Day 4, and by Day 12 all rabbits were negative for the parasite. Administration of a single oral dose of fluralaner was effective for the treatment of naturally occurring P. cuniculi infestation in rabbits during a 90 day period. © 2017 ESVD and ACVD.
... in the skin around the anus (anal fissures), surgery on the rectum, and pregnancy. It is also used for diarrhea, dysentery, irritable bowel syndrome (IBS), reducing high cholesterol, and treating cancer.
Sonnenburg, Anna; Schreiner, Maximilian; Stahlmann, Ralf
2015-12-01
Parabens, methylisothiazolinone (MI) and its derivative methylchloroisothiazolinone (MCI), are commonly used as preservatives in personal care products. They can cause hypersensitivity reactions of the human skin. We have tested a set of nine parabens, MI alone and in combination with MCI in the loose-fit coculture-based sensitization assay (LCSA). The coculture of primary human keratinocytes and allogenic dendritic cell-related cells (DC-rc) in this assay emulates the in vivo situation of the human skin. Sensitization potency of the test substances was assessed by flow cytometric analysis of the DC-rc maturation marker CD86. Determination of the concentration required to cause a half-maximal increase in CD86-expression (EC50sens) allowed a quantitative evaluation. The cytotoxicity of test substances as indicator for irritative potency was measured by 7-AAD (7-amino-actinomycin D) staining. Parabens exhibited weak (methyl-, ethyl-, propyl- and isopropylparaben) or strong (butyl-, isobutyl-, pentyl- and benzylparaben) effects, whereas phenylparaben was found to be a moderate sensitizer. Sensitization potencies of parabens correlated with side chain length. Due to a pronounced cytotoxicity, we could not estimate an EC50sens value for MI, whereas MI/MCI was classified as sensitizer and also showed cytotoxic effects. Parabens showed no (methyl- and ethylparaben) or weak irritative potencies (propyl-, isopropyl-, butyl-, isobutyl-, phenyl- and benzylparaben), only pentylparaben was rated to be irritative. Overall, we were able to demonstrate and compare the sensitizing potencies of parabens in this in vitro test. Furthermore, we showed an irritative potency for most of the preservatives. The data further support the usefulness of the LCSA for comparison of the sensitizing potencies of xenobiotics.
Choi, M; Kim, J E; Cho, K H; Lee, J H
2013-11-01
Sensitive skin is a relatively common dermatologic condition and no optimal treatments have been established so far. Low-level laser/light therapy (LLLT) has been used for its biostimulative effect in various clinical settings. The purpose of this study was to investigate whether low-level laser/light therapy can improve sensitive skin clinically and to evaluate the effects of LLLT on skin in vitro. Twenty-eight patients complaining of sensitive skin were treated with low-level polarized light, and clinical results were evaluated using subjective and objective method. To investigate possible working mechanism of LLLT on skin, cultured human keratinocytes pretreated with nontoxic concentration of sodium lauryl sulfate (SLS) were used. Cytokines released from irritated keratinocytes after LLLT were analyzed. All patients showed subjective and objective improvement after treatment. No adverse effects were reported. The average number of LLLT sessions required to achieve clinical improvement was 9.9, and cumulative dose of LLLT was 71.3 J/cm(2) on the average. Erythema index decreased significantly after LLLT treatment (p = 0.017). In vitro assay showed that LLLT significantly reduced the release of VEGF from SLS-pretreated keratinocytes (p = 0.021). Our results suggest that LLLT could be a useful and safe treatment modality for sensitive skin, and modification of inflammatory cytokines released from irritated keratinocytes may be considered as one of plausible mechanisms in sensitive skin treated with LLLT.
A Marine Hazardous Substances Data System. Volume 2.
1985-12-01
substances are considered by the Task III panel ill to exhibit the greatest potential for occupational health effects and warrant the greatest precautions for...Hazards Branch 1111 N NIOSH Registry of Toxic Effects of Chemical Substances 1121 P NIOSH/OSHA Pocket Guideto Chemical Hazards [61 U Undocumented Source...NAS Hazard Liquid or -- Rating Vapor Irritant Solid Irritant Poisons 0 No effect No effect No effect 1 Slight Effect Causes skin Slightly toxic
Zhao, Feijun; Wu, Yimou; Zhang, Xiaohong; Yu, Jian; Gu, Weiming; Liu, Shuangquan; Zeng, Tiebing; Zhang, Yuejun; Wang, Shiping
2011-10-01
In this study, the immune-modulatory and protective efficacy of using an interleukin-2 (IL-2) expression plasmid as a genetic adjuvant and chitosan (CS) nanoparticles as vectors to enhance a Tp92 DNA vaccine candidate were investigated in a Treponema pallidum (Tp) rabbit challenge model. CS vectoring of pTp92 or pIL-2 were both demonstrated to augment anti-Tp92 antibody levels induced by pTp92 DNA vaccines. Interestingly, the combination of CS vectored Tp92 and pIL-2 led to the greatest enhancements of anti-Tp92 antibodies and T-cell proliferation (p < 0.05). At week 10 after the first immunization, 15 of the 18 rabbits in each group were challenged with Tp Nichols strain and monitored for skin lesions and ulcer lesions. Ratios of positive skin lesions and ratios of ulcer lesions in groups immunized with pTp92 were significantly lower than those of the empty vector or PBS groups (p < 0.05), demonstrating that pTp92 immunization elicited significant protective efficacy against the Tp Nichols strain challenge. CS vectored and pIL-2 adjuvanted pTp92 immunized animals exhibited the lowest rates of positive skin and ulcer lesions. Male New Zealand white rabbits were randomly assigned to groups (n = 18/group) and immunized intramuscularly with pTp92 based plasmid DNA constructs (100 μg of DNA/rabbit/immunization). Two weeks before Tp challenge (Week 8), three rabbits from each group were used to determine cytokine measurements and fifteen rabbits from each group were used for Tp challenge studies. Intramuscular injection of pTp92 induced strong humoral and cellular immune responses and conferred protection from Tp challenge in rabbits. The use of CS as a pTp92 vector or pIL-2 as an adjuvant achieved a superior level of protective efficacy against Tp challenge, however CS vectored, IL-2 adjuvanted pTp92 immunization conferred the highest level of protective efficacy.
Ferraz, Isabela Leite; Barros, Guilherme Antônio Moreira de; Ferreira Neto, Patrícia Gomes; Solanki, Daneshivari; Marques, Mariângela Alencar; Machado, Vânia Maria de Vasconcelos; Cabral, Lucas Wynne; Lima, Rodrigo Moreira E; Vianna, Pedro Thadeu Galvão; Navarro, Lais Helena Camacho; Ganen, Eliana Marisa
2015-01-01
Although there is no documented evidence that tattoo pigments can cause neurological complications, the implications of performing neuraxial anesthesia through tattooed skin are unknown. In this study, we aimed to assess whether spinal puncture performed through tattooed skin of rabbits determines changes over the spinal cord and meninges. In addition, we sought to evaluate the presence of ink fragments entrapped in spinal needles. Thirty-six young male adult rabbits, each weighing between 3400 and 3900 g and having a spine length between 38.5 and 39 cm, were divided by lot into 3 groups as follows: GI, spinal puncture through tattooed skin; GII, spinal puncture through tattooed skin and saline injection; and GIII, spinal puncture through skin free of tattoo and saline injection. After intravenous anesthesia with ketamine and xylazine, the subarachnoid space was punctured at S1-S2 under ultrasound guidance with a 22-gauge 2½ Quincke needle. Animals in GII and GIII received 5 μL/cm of spinal length (0.2 mL) of saline intrathecally. In GI, the needle tip was placed into the yellow ligament, and no solution was injected into the intrathecal space; after tattooed skin puncture, 1 mL of saline was injected through the needle over a histological slide to prepare a smear that was dyed by the Giemsa method to enable tissue identification if present. All animals remained in captivity for 21 days under medical observation and were killed by decapitation. The lumbosacral spinal cord portion was removed for histological analysis using hematoxylin-eosin stain. None of the animals had impaired motor function or decreased nociception during the period of clinical observation. None of the animals from the control group (GIII) showed signs of injuries to meninges. In GII, however, 4 animals presented with signs of meningeal injury. The main histological changes observed were focal areas of perivascular lymphoplasmacyte infiltration in the pia mater and arachnoid. There was no signal of injury in neural tissue in any animal of both groups. Tissue coring containing ink pigments was noted in all GI smears from the spinal needles used to puncture the tattooed skin. On the basis of the present results, intrathecal injection of saline through a needle inserted through tattooed skin is capable of producing histological changes over the meninges of rabbits. Ink fragments were entrapped inside the spinal needles, despite the presence of a stylet.
Development of an in vitro alternative assay method for vaginal irritation.
Ayehunie, Seyoum; Cannon, Chris; Larosa, Karen; Pudney, Jeffrey; Anderson, Deborah J; Klausner, Mitchell
2011-01-11
The vaginal mucosa is commonly exposed to chemicals and therapeutic agents that may result in irritation and/or inflammation. In addition to acute effects, vaginal irritation and inflammation can make women more susceptible to infections such as HIV-1 and herpes simplex virus 2 (HSV-2). Hence, the vaginal irritation potential of feminine care formulations and vaginally administered therapeutic agents is a significant public health concern. Traditionally, testing of such materials has been performed using the rabbit vaginal irritation (RVI) assay. In the current study, we investigated whether the organotypic, highly differentiated EpiVaginal™ tissue could be used as a non-animal alternative to the RVI test. The EpiVaginal tissue was exposed to a single application of ingredients commonly found in feminine hygiene products and the effects on tissue viability (MTT assay), barrier disruption (measured by transepithelial electrical resistance, TEER and sodium fluorescein (NaFl) leakage), and inflammatory cytokine release (interleukin (IL)-1α, IL-1β, IL-6, and IL-8) patterns were examined. When compared to untreated controls, two irritating ingredients, nonoxynol 9 and benzalkonium chloride, reduced tissue viability to <40% and TEER to <60% while increasing NaFl leakage by 11-24% and IL-1α and IL-1β release by >100%. Four other non-irritating materials had minimal effects on these parameters. Assay reproducibility was confirmed by testing the chemicals using three different tissue production lots and by using tissues reconstructed from cells obtained from three different donors. Coefficients of variation between tissue lots reconstructed with cells obtained from the same donor or lots reconstructed with cells obtained from different donors were less than 10% and 12%, respectively. In conclusion, decreases in tissue viability and barrier function and increases in IL-1α and IL-1β release appear to be useful endpoints for preclinical screening of topically applied chemicals and formulations for their vaginal irritation potential. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
... dry skin Irritating chemicals, cosmetics, and other substances Parasites such as pinworms, scabies, head and body lice Pregnancy Liver, kidney, or thyroid diseases Certain cancers or cancer treatments Diseases that can affect the ...
Nair, Bindu; Elmore, Amy R
2003-01-01
Sodium Sulfite, Ammonium Sulfite, Sodium Bisulfite, Potassium Bisulfite, Ammonium Bisulfite, Sodium Metabisulfite, and Potassium Metabisulfite are inorganic salts that function as reducing agents in cosmetic formulations. All except Sodium Metabisulfite also function as hair-waving/straightening agents. In addition, Sodium Sulfite, Potassium Sulfite, Sodium Bisulfite, and Sodium Metabisulfite function as antioxidants. Although Ammonium Sulfite is not in current use, the others are widely used in hair care products. Sulfites that enter mammals via ingestion, inhalation, or injection are metabolized by sulfite oxidase to sulfate. In oral-dose animal toxicity studies, hyperplastic changes in the gastric mucosa were the most common findings at high doses. Ammonium Sulfite aerosol had an acute LC(50) of >400 mg/m(3) in guinea pigs. A single exposure to low concentrations of a Sodium Sulfite fine aerosol produced dose-related changes in the lung capacity parameters of guinea pigs. A 3-day exposure of rats to a Sodium Sulfite fine aerosol produced mild pulmonary edema and irritation of the tracheal epithelium. Severe epithelial changes were observed in dogs exposed for 290 days to 1 mg/m(3) of a Sodium Metabisulfite fine aerosol. These fine aerosols contained fine respirable particle sizes that are not found in cosmetic aerosols or pump sprays. None of the cosmetic product types, however, in which these ingredients are used are aerosolized. Sodium Bisulfite (tested at 38%) and Sodium Metabisulfite (undiluted) were not irritants to rabbits following occlusive exposures. Sodium Metabisulfite (tested at 50%) was irritating to guinea pigs following repeated exposure. In rats, Sodium Sulfite heptahydrate at large doses (up to 3.3 g/kg) produced fetal toxicity but not teratogenicity. Sodium Bisulfite, Sodium Metabisulfite, and Potassium Metabisulfite were not teratogenic for mice, rats, hamsters, or rabbits at doses up to 160 mg/kg. Generally, Sodium Sulfite, Sodium Metabisulfite, and Potassium Metabisulfite were negative in mutagenicity studies. Sodium Bisulfite produced both positive and negative results. Clinical oral and ocular-exposure studies reported no adverse effects. Sodium Sulfite was not irritating or sensitizing in clinical tests. These ingredients, however, may produce positive reactions in dermatologic patients under patch test. In evaluating the positive genotoxicity data found with Sodium Bisulfite, the equilibrium chemistry of sulfurous acid, sulfur dioxide, bisulfite, sulfite, and metabisulfite was considered. This information, however, suggests that some bisulfite may have been present in genotoxicity tests involving the other ingredients and vice versa. On that basis, the genotoxicity data did not give a clear, consistent picture. In cosmetics, however, the bisulfite form is used at very low concentrations (0.03% to 0.7%) in most products except wave sets. In wave sets, the pH ranges from 8 to 9 where the sulfite form would predominate. Skin penetration would be low due to the highly charged nature of these particles and any sulfite that did penetrate would be converted to sulfate by the enzyme sulfate oxidase. As used in cosmetics, therefore, these ingredients would not present a genotoxicity risk. The Cosmetic Ingredient Review Expert Panel concluded that Sodium Sulfite, Potassium Sulfite, Ammonium Sulfite, Sodium Bisulfite, Ammonium Bisulfite, Sodium Metabisulfite, and Potassium Metabisulfite are safe as used in cosmetic formulations.
Is dermatitis palmaris sicca an irritant contact dermatitis?
Chen, Fu-Juan; Liu, Zhen; Zhou, Ying; Chen, Yong-Hua; Fan, Yi-Ming
2013-01-01
Dermatitis palmaris sicca (DPS) is a common dry-fissured palmar dermatitis in Asian women. It may be an irritant contact dermatitis, but the immunophenotype of the cells in its infiltrate is unknown. The aim of this study was to evaluate the role of inflammatory cells in the pathogenesis of DPS. Patch testing was done in 68 patients with DPS, 87 subjects with hand eczema, and 31 healthy subjects. Immunophenotyping of cutaneous inflammatory cells was performed in 8 patients with DPS, 10 subjects with hand eczema, and 8 healthy individuals. Positive patch rates were higher in patients with DPS and those with hand eczema compared with healthy controls, but strong positive (++ or +++) reactions in DPS were fewer compared with hand eczema. Density of CD3, CD4, CD8, and CD68 cells in skin lesions of DPS and hand eczema was significantly higher than that in normal skin. Sparse CD20 cells were present only in hand eczema. Compared with hand eczema, the number of CD3, CD8, CD68, and dermal CD1a cells decreased, but epidermal CD1a cells and CD4/CD8 ratio increased in DPS. The absolute lack of CD20 cells and relative scarcity of dermal CD8 and CD1a cells in skin lesions might be insufficient to induce contact hypersensitivity, so DPS may be an irritant but not allergic contact dermatitis.
Swaile, D F; Elstun, L T; Benzing, K W
2012-03-01
Individuals with axillary hyperhidrosis have much higher than average sweat rates and are often prescribed anhydrous aluminum chloride (AlCl(3)) solutions. Topical application of these solutions can be irritating to the skin, resulting in poor compliance and lower than desired efficacy. Demonstrate the efficacy of an over the counter "clinical strength" soft-solid antiperspirant using a night time application regimen and compare to a prescription aluminum chloride (6.5%) antiperspirant using male panelists. Gravimetric hot room efficacy testing (100 F and 35% Humidity) was performed comparing an over the counter soft-solid antiperspirant to placebo in a single test. Two separate gravimetric tests were placed comparing a prescription aluminum chloride (6.5%) antiperspirant to the same soft solid product using an intent to treat model. Skin irritation was assessed daily by a trained grader. Placebo testing resulted in 85% of panelists having a reduction in sweating rate greater than 50%. Comparison testing showed the over the counter soft solid reduced sweat rate by an average of 34% better than the prescription product while resulting significantly less skin irritation. Over the counter "clinical strength" soft-solid antiperspirants can be considered as an alternative treatment to aluminum chloride antiperspirants for the treatment of heavy sweating. © 2012 The Author. BJD © 2012 British Association of Dermatologists.
Neutral endopeptidase terminates substance P-induced inflammation in allergic contact dermatitis.
Scholzen, T E; Steinhoff, M; Bonaccorsi, P; Klein, R; Amadesi, S; Geppetti, P; Lu, B; Gerard, N P; Olerud, J E; Luger, T A; Bunnett, N W; Grady, E F; Armstrong, C A; Ansel, J C
2001-01-15
Sensory nerve-derived neuropeptides such as substance P demonstrate a number of proinflammatory bioactivities, but less is known about their role in inflammatory skin disease. The cell surface metalloprotease neutral endopeptidase (NEP) is the principal proteolytic substance P-degrading enzyme. This study tests the hypothesis that the absence of NEP results in dysregulated inflammatory skin responses. The effector phase of allergic contact dermatitis (ACD) responses was examined in NEP(-/-) knockout and NEP(+/+) wild-type mice and compared with the irritant contact dermatitis response in these animals. NEP was found to be normally immunolocalized in epidermal keratinocytes and dermal blood vessels. The ACD ear swelling response was 2.5-fold higher in animals lacking NEP and was accompanied by a significant increase in plasma extravasation and infiltration of inflammatory leukocytes. The augmented ACD response in NEP(-/-) animals was abrogated by either administration of a neurokinin receptor 1 antagonist or by repeated pretreatment with topical capsaicin. Similar to NEP(-/-) mice, the acute inhibition of NEP in NEP(+/+) animals resulted in an augmented ACD response. In contrast to the ACD responses, little differences were observed in the irritant contact dermatitis response of NEP(-/-) compared with NEP(+/+) animals after epicutaneous application of the skin irritants croton oil or SDS. Thus, these results indicate that NEP and cutaneous neuropeptides have a significant role in the pathogenesis of ACD.
Xiong, Wu; Yan, Yu; Hu, Feng; Liu, Can; Wang, Shaohua; Chen, Jia; Wang, Xueqi; Zhou, Jianda
2016-01-01
Ear reconstruction is one of the most complicated and challenging techniques in plastic surgery because of the histologic and anatomic properties of the ear. Success depends on fitting the auriform cartilage scaffold into the overlying skin, but current approaches can just give results that are not lifelike and can lead to complications. A novel double-capsule, double-valve plastic ear expander was designed and implanted subcutaneously on either side of the dorsum of six New Zealand white rabbits (two expanders per rabbit). The outer capsule was expanded by injecting approximately 120 mL of physiological saline, then withdrawing the liquid on two occasions. Next, the ear-shaped inner capsule was filled with high-hardness plaster, and the external capsule was emptied such that the expanded skin flap and external capsule responded to the negative pressure and closed over the ear-shaped inner capsule. As a result, the skin flap adopted an ear shape. The ear expander was left in place for 4 wk, removed with the help of a mini-incision, and stripped of its fibrous capsule. To simulate human ear reconstruction, the expander was replaced with an auriform silicone prosthesis, and the effects of auricular reconstruction were observed dynamically. All 12 skin flaps maintained abundant blood supply, created a clear outline of the ear framework, and produced a lifelike result. No complications were observed during the 4-wk observation period. The expanded skin flaps described here can mold to the desired contours and appear lifelike, as well as maintain abundant blood supply. This may provide a simpler approach to total ear reconstruction that reduces risk of complications. Copyright © 2016 Elsevier Inc. All rights reserved.
Use of the Bovine Udder Skin model to evaluate the tolerability of Mesem cosmetic cream.
Raak, Christa; Molsberger, Friedrich; Pittermann, Wolfgang; Bertram, Mathias; Robens, Sibylle; Ostermann, Thomas
2017-09-01
Observational studies of Mesem cream (based on Mesembryanthemum crystallinum L. plant extract) found that it had positive effects on skin hydration and smoothing of the skin. However, some patients reported skin irritation effects. The current study evaluated the skin tolerability of Mesem cream, as compared to the carrier cream (without the active ingredient), by using the isolated perfused bovine udder skin model. The primary outcomes investigated were cytotoxicity (i.e. cell viability), assessed with the MTT assay, and irritancy and inflammation, assessed by measuring PGE₂ tissue levels. A total reaction score was calculated by combining the results for each parameter. In the case of a single topical application, significant differences were found between the carrier cream and the Mesem cream. While the application of carrier cream resulted in low cytotoxicity (-8.4% change in viability, as compared to the untreated control), the Mesem cream was more cytotoxic (-18.7% change). In addition, one hour after application, PGE₂ levels were higher in Mesem cream-treated skin, as compared to carrier cream-treated skin (16.6% versus 11.3%). Further experiments (tape-stripped skin and repeated application) also found significant differences between the two creams in the results obtained. Evaluation of the effectiveness, safety and tolerability of phyto-cosmetic products is important. Our results confirmed the findings of two previous human observational studies (the human patch test and open application study). Future experiments to understand the underlying principles of its effectiveness, safety and tolerability should include extracts of M. crystallinum L. juice, as well as the Mesem cream itself. 2017 FRAME.
Hoffmann, J; Heisler, E; Karpinski, S; Losse, J; Thomas, D; Siefken, W; Ahr, H-J; Vohr, H-W; Fuchs, H W
2005-10-01
The determination of a possible corrosive or irritative potential of certain products and ingredients is necessary for their classification and labeling requirements. Reconstructed skin as a model system provides fundamental advantages to single cell culture testing and leads to promising results as shown by different validation studies (for review: Fentem, J.H., Botham, P.A., 2002. ECVAM's activities in validating alternative tests for skin corrosion and irritation. ATLA 30(Suppl. 2), 61-67). In this study we introduce our new reconstructed epidermis "Epidermal-Skin-Test" (EST-1,000). This fully grown epidermis consists of proliferating as well as differentiating keratinocytes. EST-1,000 shows a high comparability to normal human skin as shown by histological and immunohistochemical data. Characteristic markers (KI-67, CK 1/10/5/14, transglutaminase, collagen IV, involucrin, beta 1 integrin) can be identified easily. The main focus of this work was to characterize EST-1,000 especially with respect to its barrier function by testing several substances of known corrosive potential. Skin corrosion was detected by the cytotoxic effect of the substances on a reconstructed epidermis after short-term application to the stratum corneum. The effect was determined by standard MTT assay and accompanying histological analysis. Hence EST-1,000 shows a very high predictive potential and closes the gap between animal testing and the established full-thickness model Advanced-Skin-Test 2,000 (AST-2,000) (Noll, M., Merkle, M.-L., Kandsberger, M., Matthes, T., Fuchs, H., Graeve, T., 1999. Reconstructed human skin (AST-2,000) as a tool for pharmaco-toxicology. ATLA 27, 302).
Final report on the safety assessment of Arnica montana extract and Arnica montana.
2001-01-01
Arnica Montana Extract is an extract of dried flowerheads of the plant, Arnica montana. Arnica Montana is a generic term used to describe a plant material derived from the dried flowers, roots, or rhizomes of A. montana. Common names for A. montana include leopard's bane, mountain tobacco, mountain snuff, and wolf's bane. Two techniques for preparing Arnica Montana Extract are hydroalcoholic maceration and gentle disintegration in soybean oil. Propylene glycol and butylene glycol extractions were also reported. The composition of these extracts can include fatty acids, especially palmitic, linoleic, myristic, and linolenic acids, essential oil, triterpenic alcohols, sesquiterpene lactones, sugars, phytosterols, phenol acids, tannins, choline, inulin, phulin, arnicin, flavonoids, carotenoids, coumarins, and heavy metals. The components present in these extracts are dependent on where the plant is grown. Arnica Montana Extract was reported to be used in almost 100 cosmetic formulations across a wide range of product types, whereas Arnica Montana was reported only once. Extractions of Arnica Montana were tested and found not toxic in acute toxicity tests in rabbits, mice, and rats; they were not irritating, sensitizing, or phototoxic to mouse or guinea pig skin; and they did not produce significant ocular irritation. In an Ames test, an extract of A. montana was mutagenic, possibly related to the flavenoid content of the extract. No carcinogenicity or reproductive/developmental toxicity data were available. Clinical tests of extractions failed to elicit irritation or sensitization, yet Arnica dermatitis, a delayed type IV allergy, is reported in individuals who handle arnica flowers and may be caused by sesquiterpene lactones found in the flowers. Ingestion of A. montana-containing products has induced severe gastroenteritis, nervousness, accelerated heart rate, muscular weakness, and death. Absent any basis for concluding that data on one member of a botanical ingredient group can be extrapolated to another in the group, or to the same ingredient extracted differently, these data were not considered sufficient to assess the safety of these ingredients. Additional data needs include current concentration of use data; function in cosmetics; ultraviolet (UV) absorption data-if absorption occurs in the UVA or UVB range, photosensitization data are needed; gross pathology and histopathology in skin and other major organ systems associated with repeated dermal exposures; dermal reproductive/developmental toxicity data; inhalation toxicity data, especially addressing the concentration, amount delivered, and particle size; and genotoxicity testing in a mammalian system; if positive, a 2-year dermal carcinogenicity assay performed using National Toxicology Program (NTP) methods is needed. Until these data are available, it is concluded that the available data are insufficient to support the safety of these ingredients in cosmetic formulations.
Sarkar, Gunjan; Saha, Nayan Ranjan; Roy, Indranil; Bhattacharyya, Amartya; Bose, Madhura; Mishra, Roshnara; Rana, Dipak; Bhattacharjee, Debashis; Chattopadhyay, Dipankar
2014-05-01
The aim of this work is to examine the effectiveness of mucilage/hydroxypropylmethylcellulose (HPMC) based transdermal patch (matrix type) as a drug delivery device. We have successfully extracted mucilage from Colocasia esculenta (Taro) corms and prepared diltiazem hydrochloride incorporated mucilage/HPMC based transdermal patches using various wt% of mucilage by the solvent evaporation technique. Characterization of both mucilage and transdermal patches has been done by several techniques such as Molisch's test, organoleptic evaluation of mucilage, mechanical, morphological and thermal analysis of transdermal patches. Skin irritation test is studied on hairless Albino rat skin showing that transdermal patches are apparently free of potentially hazardous skin irritation. Fourier transform infrared analysis shows that there is no interaction between drug, mucilage and HPMC while scanning electron microscopy shows the surface morphology of transdermal patches. In vitro drug release time of mucilage-HPMC based transdermal patches is prolonged with increasing mucilage concentration in the formulation. Copyright © 2014 Elsevier B.V. All rights reserved.
Antunes, E; Marangoni, R A; Giglio, J R; Brain, S D; de Nucci, G
1993-11-01
Phoneutria nigriventer venom was fractionated by gel filtration followed by ion-exchange chromatography from which 16 fractions (I-XVI) were obtained and assayed in rabbit skin in order to identify those responsible for the increased vascular permeability observed with the whole venom. The fractions, and control mediators (tissue kallikrein, bradykinin and histamine) were intradermally injected in male New Zealand white rabbits. Local oedema formation was measured as the local accumulation of i.v. injected 125I-human serum albumin into skin sites. Fraction XIII was the only fraction assayed which significantly induced oedema formation. Fraction XIII-induced oedema was greatly reduced by either the protease inhibitor aprotinin or the bradykinin B2 receptor antagonist D-Arg,[Hyp3,Thi5,8D-Phe7]-Bk, whereas the plasma kallikrein inhibitor soybean trypsin inhibitor failed to significantly affect this oedematogenic response. The kininase II inhibitor captopril markedly potentiated fraction XIII-induced oedema. Our results indicate that the increased vascular permeability induced by fraction XIII is due to local generation of kinins in response to tissue (but not plasma) kallikrein-kinin system activation.
Incorporation of Uranium: II. Distribution of Uranium Absorbed through the Lungs and the Skin
Walinder, G.; Fries, B.; Billaudelle, U.
1967-01-01
In experiments on mice, rabbits, and piglets the distribution of uranium was studied at different times after exposure. Uranium was administered by inhalation (mice) and through the skin (rabbits and piglets). These investigations show that the uptakes of uranium in different organs of the three species are highly dependent on the amounts administered. There seems to be a saturation effect in the spleen and bone tissue whenever the uranium concentration in the blood exceeds a certain level. The effect in the kidney is completely different. If, in a series of animals, the quantity of uranium is continuously increased, the uptakes by the kidneys increase more rapidly than the quantities administered. This observation seems to be consistent with the toxic effects of uranium on the capillary system in the renal cortex. Polyphloretin phosphate, a compound which reduces permeability, was investigated with respect to its effect on the uptake of uranium deposited in skin wounds in rabbits and piglets. It significantly reduced the absorption of uranium, even from depots in deep wounds. The findings are discussed with reference to the routine screening of persons exposed to uranium at AB Atomenergi. Images PMID:6073090
Intracellular Adenosine Triphosphate Delivery Enhanced Skin Wound Healing in Rabbits
Wang, Jianpu; Zhang, Qunwei; Wan, Rong; Mo, Yiqun; Li, Ming; Tseng, Michael T.; Chien, Sufan
2016-01-01
Small unilamellar lipid vesicles were used to encapsulate adenosine triphosphate (ATP-vesicles) for intracellular energy delivery. This technique was tested in full-thickness skin wounds in 16 adult rabbits. One ear was rendered ischemic by using a minimally invasive surgery. The other ear served as a normal control. Four circular full-thickness wounds were created on the ventral side of each ear. ATP-vesicles or saline was used and the wounds were covered with Tegaderm (3M, St. Paul, MN). Dressing was changed and digital photos were taken daily until all the wounds were healed. The mean healing times of ATP-vesicles–treated wounds were significantly shorter than that of saline-treated wounds on ischemic and nonischemic ears. Histologic study indicated better-developed granular tissue and reepithelial-ization in the ATP-vesicles–treated wounds. The wounds treated by ATP-vesicles exhibited extremely fast granular tissue growth. More CD31 positive cells were seen in the ATP-vesicles–treated wounds. This preliminary study shows that direct intracellular delivery of ATP can accelerate the healing process of skin wounds on ischemic and nonischemic rabbit ears. The extremely fast granular tissue growth was something never seen or reported in the past. PMID:19158531
Depigmentation with tert-butyl hydroquinone using black guinea pigs.
Patrick, E; Juberg, D R; O'Donoghue, J; Maibach, H I
1999-01-01
tert-Butyl hydroquinone (TBHQ) has important and functional uses in consumer and commercial applications, some of which involve human exposure primarily through dermal contact. To assist in the safety evaluation of TBHQ, this study was conducted to determine whether TBHQ would produce changes in skin pigmentation after repeated dermal application to black guinea pigs. Hydroquinone (HQ) and hydroquinone monomethyl ether (HQMME) were used as positive controls. TBHQ and HQ were tested at concentrations of 0.1, 1.0 and 5.0%, while HQMME was tested at a concentration of 10.0%. Groups of five males and five females were dosed with TBHQ, HQ, or the vehicle (hydrophilic ointment) daily (M-F) for 13 weeks. In addition, animals (five males, five females) treated with HQMME received 13 doses over a 3-week period. The application site was evaluated weekly for degree of pigmentation loss and irritation. Twenty-four hours after final application, sites were evaluated for depigmentation, irritation and hyperpigmentation. Subsequently, the application site was depilated and re-evaluated for the same endpoints. Repetitive exposure to concentrations of 1.0% and 5.0% TBHQ and HQ were slightly to moderately irritating, while 0.1% of each of these test materials produced only weak irritant responses. No irritant responses to hydrophilic ointment were observed and HQMME produced weak irritant responses after 2 weeks. Neither 0.1% TBHQ nor HQ produced depigmentation, while 20% of animals dosed with 1.0% TBHQ and 30% of animals dosed with 1.0% HQ had spotty or uniform loss of pigment at the site of treatment. Approximately 40% of animals dosed with 5% TBHQ or HQ were depigmented at the treatment site at the final evaluation. HQMME produced complete depigmentation of the skin and hair in all animals. Hyperpigmentation of the treatment site was observed in 80-100% of animals in all groups (with the exception of HQMME-treated animals, treated for only 3 weeks), which may be attributable to the use of hydrophilic ointment as the vehicle, the application procedure, or simply clipping hair from the skin. Thus, this study showed that TBHQ causes depigmentation in black guinea pigs at concentrations of 1% or greater, but that a no-effect threshold for this endpoint exists at a concentration between 0.1 and 1.0%.
Cressey, Brienne D; Belum, Viswanath R; Scheinman, Pamela; Silvestri, Dianne; McEntee, Nancy; Livingston, Vashti; Lacouture, Mario E; Zippin, Jonathan H
2017-01-01
Peristomal dermatitis is a common complication for the >700 000 patients in the United States with an ostomy. The role of stoma skin care products in peristomal dermatitis is poorly understood. To evaluate stoma skin care products as a cause of peristomal dermatitis. A retrospective chart review of patients with peristomal dermatitis at four academic hospitals from January 2010 to March 2014 was performed. Patient demographics, clinical information and use test and patch test results were documented. Eighteen patients identified as having peristomal dermatitis were tested. Twelve of these had peristomal contact dermatitis. We identified numerous stoma skin care products as triggers of irritant and/or allergic contact dermatitis. The most common stoma skin care product used and/or involved in dermatitis was Cavilon™ No Sting Barrier Film. Our data support a paradigm shift whereby healthcare workers treating patients with peristomal dermatitis, which is currently considered to be a reaction mainly to bodily fluids, must consider those products used to protect the skin as potential triggers for this disease. Therefore, patients with peristomal dermatitis should be tested with their stoma skin care agents to determine the need for removal or change of these products. Additionally, full ingredient labelling by manufacturers would help identify new allergens and irritants. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Wolf, Martin; Halper, Maria; Pribyl, Raffaela; Baurecht, Dieter; Valenta, Claudia
2017-03-15
The spatial distribution of exogenous substances in the stratum corneum (SC) could have an influence on their skin irritation potential. In this study it was possible to monitor the distribution of phospholipids with their phosphatidylcholine scaffold on porcine ear skin by combining tape stripping and in vitro ATR-FTIR spectroscopy. Significant vibrational modes in the spectra could be successfully assigned to the functional groups of the molecules. Thus it was possible to track the phospholipids without the need of their deuterated form by calculating difference spectra from the treated - untreated skin samples. The correlation between four characteristic bands (R 2 ≥0.9909) revealed the excellent suitability of this semi-quantitative method for deep profiling analysis. The penetration capabilities of aqueous suspensions of the different phospholipid compositions as well as two monoacyl-phosphatidylcholine based liposome formulations were investigated using this method. Nevertheless, differences in the distribution of the investigated phospholipid species, having different amounts of monoacyl-phosphatidylcholine, could not be found. It could be clearly shown that the deepest skin penetration was seen in the irritating anionic SDS (sodium dodecyl sulfate) out of the aqueous solution. The aqueous suspensions based on different phospholipid surfactants showed the same range of penetration depth (10-15% of SC), whereas the smallest skin penetration depth was observed after the application of liposomal formulations. Copyright © 2017 Elsevier B.V. All rights reserved.
... girlshealth.gov/ Home Body Puberty Body hair Body hair Even before you get your first period , you ... removing pubic hair Ways to get rid of hair top Removing body hair can cause skin irritation, ...
Laundering Your Baby's Clothes
... and fragrances that can irritate skin. Note: Cloth diapers do need to be separated from your regular laundry because harsh detergents can cause diaper rash . Wash these with mild baby detergent in ...
75 FR 74634 - Spiroxamine; Pesticide Tolerances
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-01
... is a skin sensitizer when tested in guinea pigs and is a severe dermal irritant. Spiroxamine... production (NAICS code 111). Animal production (NAICS code 112). Food manufacturing (NAICS code 311...
Skin reactions related to hand hygiene and selection of hand hygiene products.
Larson, Elaine; Girard, Raphaelle; Pessoa-Silva, Carmem Lucia; Boyce, John; Donaldson, Liam; Pittet, Didier
2006-12-01
In October 2004, The World Health Organization (WHO) launched the World Alliance for Patient Safety. Within the alliance, the first priority of the Global Patient Safety Challenge is to reduce health care-associated infection. A key action within the challenge is to promote hand hygiene in health care globally as well as at the country level through the campaign "Clean Care is Safer Care." As a result, the WHO is developing Guidelines on Hand Hygiene in Health Care, designed to be applicable throughout the world. This paper summarizes one component of the global WHO guidelines related to the impact of hand hygiene on the skin of health care personnel, including a discussion of types of skin reactions associated with hand hygiene, methods to reduce adverse reactions, and factors to consider when selecting hand hygiene products. Health care professionals have a higher prevalence of skin irritation than seen in the general population because of the necessity for frequent hand hygiene during patient care. Ways to minimize adverse effects of hand hygiene include selecting less irritating products, using skin moisturizers, and modifying certain hand hygiene practices such as unnecessary washing. Institutions need to consider several factors when selecting hand hygiene products: dermal tolerance and aesthetic preferences of users as well as practical considerations such as convenience, storage, and costs.
Retinoids in the treatment of skin aging: an overview of clinical efficacy and safety
Mukherjee, Siddharth; Date, Abhijit; Patravale, Vandana; Korting, Hans Christian; Roeder, Alexander; Weindl, Günther
2006-01-01
Aging of skin is an intricate biological process consisting of two types. While intrinsic or chronological aging is an inevitable process, photoaging involves the premature aging of skin occurring due to cumulative exposure to ultraviolet radiation. Chronological and photoaging both have clinically differentiable manifestations. Various natural and synthetic retinoids have been explored for the treatment of aging and many of them have shown histological and clinical improvement, but most of the studies have been carried out in patients presenting with photoaged skin. Amongst the retinoids, tretinoin possibly is the most potent and certainly the most widely investigated retinoid for photoaging therapy. Although retinoids show promise in the treatment of skin aging, irritant reactions such as burning, scaling or dermatitis associated with retinoid therapy limit their acceptance by patients. This problem is more prominent with tretinoin and tazarotene whereas other retinoids mainly represented by retinaldehyde and retinol are considerably less irritating. In order to minimize these side effects, various novel drug delivery systems have been developed. In particular, nanoparticles have shown a good potential in improving the stability, tolerability and efficacy of retinoids like tretinoin and retinol. However, more elaborate clinical studies are required to confirm their advantage in the delivery of topical retinoids. PMID:18046911
Kuzmina, Natalia; Hagströmer, Lena; Nyrén, Miruna; Emtestam, Lennart
2003-11-01
Identification of subjects at risk for contact dermatitis by screening tests is desirable in order to adjust the preventive measures to individual skin susceptibility. The present study aimed to examine the effects of basic physiological features, such as baseline electrical impedance (IMP) and transepidermal water loss (TEWL), on reactivity to sodium lauryl sulphate (SLS). On the basis of two previous studies, we re-evaluated the experimental irritant skin reactions (50 microL of 2% SLS in large Finn Chambers for 24 h) on the volar forearms of 29 patients with eczema and 19 healthy controls. We found definite differences in the baseline values of IMP, between the patients and the controls. Moreover, patients with eczema showed higher TEWL and lower MIX values on day 3 after exposure to SLS, which may indicate differences in SLS reactivity. After the study, the biophysical parameters of the eczema patients did not return to baseline, which suggests that their skin heals more slowly than that of normal subjects. Our findings indicate that the IMP technique may help to 'detect' chemically vulnerable skin. However, more studies are needed to determine the value of the basal electrical impedance parameters in assessing the risk of developing irritant contact dermatitis.
Hines, J; Wilkinson, S M; John, S M; Diepgen, T L; English, J; Rustemeyer, T; Wassilew, S; Kezic, S; Maibach, H I
2017-01-01
Contact dermatitis is one of the most common occupational diseases, with serious impact on quality of life, lost days at work and a condition that may be chronically relapsing. Regular prophylactic skin cream application is widely acknowledged to be an effective prevention strategy against occupational contact dermatitis; however, compliance rates remain low. To present a simple programme for skin cream application in the workplace with focus on implementation to drive down the rate of occupational irritant contact dermatitis, an expert panel of eight international dermatologists combined personal experience with extensive literature review. The recommendations are based on clinical experience as supported by evidence-based data from interventional studies. The authors identified three moments for skin cream application in the work place: (i) before starting a work period; (ii) after washing hands; and (iii) after work. Affecting behaviour change requires systematic communications, monitoring and reporting, which is proposed through Kotter's principles of organizational change management. Measurement tools are provided in the appendix. Interventional data based on application of this proposal is required to demonstrate its effectiveness. © 2016 The Authors. Journal of the European Academy of Dermatology and Venereology published by John Wiley & Sons Ltd on behalf of European Academy of Dermatology and Venereology.
Effects of JP-8 on Molecular and Histological Parameters Related to Acute Skin Irritation
2000-06-01
in irritant dermatitis are understood. Cytokines are cell signaling molecules that are involved in the inflammatory response. These include the...are involved in inflammatory responses in contact dermatitis (Figure 2, Ormerod et al., 1997). The analysis of iNOS mRNA or protein, as well as the...placed into a Bessman steel tissue pulverizer (Fisher Scientific, Cat # 08-418-2) that was pre-chilled in liquid nitrogen. Using a lead hammer
Casterton, P L; Potts, L F; Klein, B D
1994-08-01
11 surfactant raw materials with potential applications in light-duty liquid cleaning products were evaluated in vitro using a human skin analogue (ATS SKIN(2) Model ZK1100) for predicting cytotoxicity (MTT reduction) and inflammation [prostaglandin E(2) (PGE(2)) release]. Two of the 11 raw materials, both in the same compound family, were selected to be individually combined with each of the other nine in a 90:10 (raw:selected raw) mixture. Selection criteria were based on desired performance characteristics and low irritation potential as suggested from the individual surfactant assay data. To determine whether irritation potential was mitigated, MTT and PGE(2) scores were again determined for each of the 18 combinations with the resulting data being compared with the untreated raw material data. A plot of the data indicated that one of two selected materials may have an 'anti-irritant' effect. For raw materials with intrinsic MTT scores of less than 50 mug/ml and with the original data corrected for possible dilution effects, a statistical comparison between individual raw materials and the two sets of combinations was done using a one-sample analysis. Both cytotoxicity (MTT) and inflammation (PGE(2)) were significantly decreased by the milder of the two selected raw materials. By factoring the data into future new product decisions, this methodology has become a useful and practical tool for Amway product development.
Comparative Study of the Biological Activity of Allantoin and Aqueous Extract of the Comfrey Root.
Savić, Vesna Lj; Nikolić, Vesna D; Arsić, Ivana A; Stanojević, Ljiljana P; Najman, Stevo J; Stojanović, Sanja; Mladenović-Ranisavljević, Ivana I
2015-08-01
This study investigates the biological activity of pure allantoin (PA) and aqueous extract of the comfrey (Symphytum officinale L.) root (AECR) standardized to the allantoin content. Cell viability and proliferation of epithelial (MDCK) and fibroblastic (L929) cell line were studied by using MTT test. Anti-irritant potential was determined by measuring electrical capacitance, erythema index (EI) and transepidermal water loss of artificially irritated skin of young healthy volunteers, 3 and 7 days after application of creams and gels with PA or AECR. Pure allantoin showed mild inhibitory effect on proliferation of both cell lines at concentrations 40 and 100 µg/ml, but more pronounced on MDCK cells. Aqueous extract of the comfrey root effect on cell proliferation in concentrations higher than 40 µg/ml was significantly stimulatory for L929 but inhibitory for MDCK cells. Pharmaceutical preparations that contained AECR showed better anti-irritant potential compared with PA. Creams showed better effect on hydration and EI compared with the gels that contained the same components. Our results indicate that the biological activity of the comfrey root extract cannot be attributed only to allantoin but is also likely the result of the interaction of different compounds present in AECR. Topical preparations that contain comfrey extract may have a great application in the treatment of skin irritation. Copyright © 2015 John Wiley & Sons, Ltd.
Natural Oils for Skin-Barrier Repair: Ancient Compounds Now Backed by Modern Science.
Vaughn, Alexandra R; Clark, Ashley K; Sivamani, Raja K; Shi, Vivian Y
2018-02-01
Natural plant oils are commonly used as topical therapy worldwide. They are usually easily accessible and are relatively inexpensive options for skin care. Many natural oils possess specific compounds with antimicrobial, antioxidant, anti-inflammatory, and anti-itch properties, making them attractive alternative and complementary treatments for xerotic and inflammatory dermatoses associated with skin-barrier disruption. Unique characteristics of various oils are important when considering their use for topical skin care. Differing ratios of essential fatty acids are major determinants of the barrier repair benefits of natural oils. Oils with a higher linoleic acid to oleic acid ratio have better barrier repair potential, whereas oils with higher amounts of irritating oleic acid may be detrimental to skin-barrier function. Various extraction methods for oils exist, including cold pressing to make unrefined oils, heat and chemical distillation to make essential oils, and the addition of various chemicals to simulate a specific scent to make fragranced oils. The method of oil processing and refinement is an important component of selecting oil for skin care, and cold pressing is the preferred method of oil extraction as the heat- and chemical-free process preserves beneficial lipids and limits irritating byproducts. This review summarizes evidence on utility of natural plant-based oils in dermatology, particularly in repairing the natural skin-barrier function, with the focus on natural oils, including Olea europaea (olive oil), Helianthus annus (sunflower seed oil), Cocos nucifera (coconut oil), Simmondsia chinesis (jojoba oil), Avena sativa (oat oil), and Argania spinosa (argan oil).
Tsuchiyama, Hiromi; Maeda, Akihisa; Nakajima, Mayumi; Kitsukawa, Mika; Takahashi, Kei; Miyoshi, Tomoya; Mutsuga, Mayu; Asaoka, Yoshiji; Miyamoto, Yohei; Oshida, Keiyu
2017-10-05
The murine local lymph node assay (LLNA) is widely used to test chemicals to induce skin sensitization. Exposure of mouse auricle skin to a sensitizer results in proliferation of local lymph node T cells, which has been measured by in vivo incorporation of H 3 -methyl thymidine or 5-bromo-2'-deoxyuridine (BrdU). The stimulation index (SI), the ratio of the mean proliferation in each treated group to that in the concurrent vehicle control group, is frequently used as a regulatory-authorized endpoint for LLNA. However, some non-sensitizing irritants, such as sodium dodecyl sulfate (SDS) or methyl salicylate (MS), have been reported as false-positives by this endpoint. In search of a potential endpoint to enhance the specificity of existing endpoints, we evaluated 3 contact sensitizers; (hexyl cinnamic aldehyde [HCA], oxazolone [OXA], and 2,4-dinitrochlorobenzene [DNCB]), 1 respiratory sensitizer (toluene 2,4-diisocyanate [TDI]), and 2 non-sensitizing irritants (MS and SDS) by several endpoints in LLNA. Each test substance was applied to both ears of female CBA/Ca mice daily for 3 consecutive days. The ears and auricle lymph node cells were analyzed on day 5 for endpoints including the SI value, lymph node cell count, cytokine release from lymph node cells, and histopathological changes and gene expression profiles in auricle skin. The SI values indicated that all the test substances induced significant proliferation of lymph node cells. The lymph node cell counts showed no significant changes by the non-sensitizers assessed. The inflammatory findings of histopathology were similar among the auricle skins treated by sensitizers and irritants. Gene expression profiles of cytokines IFN-γ, IL-4, and IL-17 in auricle skin were similar to the cytokine release profiles in draining lymph node cells. In addition, the gene expression of the chemokine CXCL1 and/or CXCL2 showed that it has the potential to discriminate sensitizers and non-sensitizing irritants. Our results suggest that multi-endpoint analysis in the LLNA leads to a better determination of the sensitizing potential of test substances. We also show that the gene expression of CXCL1 and/or CXCL2, which is involved in elicitation of contact hypersensitivity (CHS), can be a possible additional endpoint for discrimination of sensitizing compounds in LLNA. Copyright © 2017 Elsevier B.V. All rights reserved.
Yamamoto, Naoki; Kato, Yoshinao; Sato, Atsushi; Hiramatsu, Noriko; Yamashita, Hiromi; Ohkuma, Mahito; Miyachi, Ei-Ichi; Horiguchi, Masayuki; Hirano, Koji; Kojima, Hajime
2016-08-01
In vitro test methods that use human corneal epithelial cells to evaluate the eye irritation potency of chemical substances do not use human corneal epithelium because it has been difficult to maintain more than four passages. In this study, we make a new cell line comprising immortalized human corneal epithelial cells (iHCE-NY1). The IC50 of iHCE-NY1 cells is slightly higher than that of Statens Seruminstitut Rabbit Cornea (SIRC) cells, which are currently used in some in vitro test methods. CDKN1A in iHCE-NY1 cells was used as a marker of gene expression to indicate cell cycle activity. This enabled us to evaluate cell recovery characteristics at concentrations lower than the IC50 of cytotoxic tests.
... often linked to strep infections, especially in children. Inverse -- Skin redness and irritation occur in the armpits, ... The goal of treatment is to control your symptoms and prevent ... and shampoos -- These are called topical treatments. Pills ...
Hereditary fructose intolerance
... person without this substance eats fructose or sucrose (cane or beet sugar, table sugar), complicated chemical changes ... include: Convulsions Excessive sleepiness Irritability Yellow skin or whites of the eyes (jaundice) Poor feeding as a ...
Zinc oxide is an ingredient in many products. Some of these are certain creams and ointments used ... prevent or treat minor skin burns and irritation. Zinc oxide overdose occurs when someone eats one of ...
Lachapelle, Jean-Marie; Gimenez-Arnau, Ana; Metz, Martin; Peters, Jill; Proksch, Ehrhardt
2018-05-01
Contact dermatitis (CD) is caused by environmental agents, irritants, and allergens that penetrate the epidermis and lead to inflammation. An intact skin barrier prevents penetration and is important in maintaining healthy skin. Classical diagnosis of CD is made using the patch test, and traditional treatment strategies for CD promote skin barrier integrity and resolve the inflammatory component of the condition. This can be achieved by using emollient-based therapy, which is most important for skin barrier repair, and in addition to topical glucocorticosteroids, which are used in severe cases of CD and are most effective in reducing inflammation. Preventative measures, such as irritant and allergen avoidance in the workplace, also play a pivotal role in effective CD management. Moreover, CD management necessitates a holistic approach that incorporates prevention, barrier repair, and inflammatory resolution to ensure optimized efficacy. It is also important to consider potential barriers to optimal management when evaluating individuals with CD, such as limited patient education or poor access to care. Finally, key literature and our own clinical practice experience have highlighted the value of patient preference, as well as safety, efficacy and simplicity, in building the perfect emollient.
Scutellaria radix Extract as a Natural UV Protectant for Human Skin.
Seok, Jin Kyung; Kwak, Jun Yup; Choi, Go Woon; An, Sang Mi; Kwak, Jae-Hoon; Seo, Hyeong-Ho; Suh, Hwa-Jin; Boo, Yong Chool
2016-03-01
Ultraviolet (UV) radiation induces oxidative injury and inflammation in human skin. Scutellaria radix (SR, the root of Scutellaria baicalensis Georgi) contains flavonoids with high UV absorptivity and antioxidant properties. The purpose of this study was to examine the potential use of SR extract as an additive in cosmetic products for UV protection. SR extract and its butanol (BuOH) fraction strongly absorbed UV radiation and displayed free radical scavenging activity against 2,2-diphenyl-1-picrylhydrazyl radials and 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid) radicals. They also attenuated the UV-induced death of HaCaT cells. Sunscreen creams, with or without supplementation of SR extract BuOH fraction, were tested in vivo in human trials to evaluate potential skin irritation and determine the sun protection factor (SPF). Both sunscreen creams induced no skin irritation. A sunscreen cream containing 24% ZnO showed an SPF value of 17.8, and it increased to 22.7 when supplemented with 5% SR extract BuOH fraction. This study suggests that SR-derived materials are useful as safe cosmetic additives that provide UV protection. Copyright © 2015 John Wiley & Sons, Ltd.
R&D of Energetic Ionic Liquids
2011-11-01
Ammonia 3-6 H2O balance Properties LMP-103S AF - M315E Hydrazine Ispvac,lbf sec/lbm (e = 50:1 Pc = 300 psi) 252 (theor.) 235 (del) 266...Distribution A: Public Release, Distribution unlimited. AF - M315E is US Air Force IL-Based Monopropellant •Significant physical property and performance...6 Toxicity Assessment of AF - M315E Toxicity Testing Results PROPERTY AF - M315E HYDRAZINE LD50 (rat), mg/kg 550 60 Dermal Irritation (rabbit
Febriana, Sri Awalia; Soebono, Hardyanto; Coenraads, Pieter-Jan
2014-02-01
Shoe manufacturing workers are exposed daily to an extensive range of potential physical and chemical occupational hazards. Shoe manufacturing in Indonesia is one of the industrial sectors that has shown sustained growth amongst the newly industrialized countries (NICs). In this study, we investigated the possible potential exposure of the workers to physical and occupational hazards and determined the prevalence of occupational skin diseases at a shoe manufacturing factory in Indonesia. A cross-sectional study on the observation of the working process and an inventory and risk assessment of exposure to the chemicals used. Classification of chemicals as potential sensitizers/irritants and qualitative assessments of these chemicals were done. Workers were examined and interviewed using the Nordic Occupational Skin Questionnaire-2002/LONG. The risk of Occupational skin diseases (OSD) at the shoe factory was mainly related to the exposure of the workers' skin to potential physical and chemical hazards in hot and humid environmental conditions. From a total of 514 workers, 8.5 % reported current OSD and 4.8 % reported a history of OSD. Occupational skin diseases were diagnosed in 29 % of the workers by dermatologists and 7.6 % had an occupational contact dermatitis (OCD). Of the 39 workers with contact dermatitis, 33 consented to being patch tested, 14 (3 %) workers showed a positive results and considered as having an occupational allergic contact dermatitis (OACD) and 25 (4.9 %) had an occupational irritant contact dermatitis (OICD). We observed a repeated and prolonged exposure of the workers to numerous physical and chemical skin hazards at this factory.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kahn, R.L.
1963-03-01
Twenty-four hrs after 1000-r x irradiation of a small area of the skin of rabbits, they were injected with a suspension of staphylococci subcutaneously in the irradiated area and in a nonirradiated control area. Localized lesions were most marked in nonirradiated areas and in some animals no visible lesions were noted in irradiated areas. The mild inflammatory lesions in irradiated areas corroborate the point of view, that irradiation is anti-inflammatory. The reason for mild lesions must be the reduced localization of staphylococci in irradiated areas and their escape from those areas. It is suggested that the antilocalizing property of irradiationmore » is probably the basis for the antiinflammatory action. When the concentration of organisms injected in the irradiated area was high (10 billion), septicemia and death of the rabbits occurred, presumably as a result of the antilocalizing property of irradiation, which permitted the escape of the organisms from the injected area. In animals injected in irradiated areas with either 0.5 or 5 billion organisms, no septicemia was observed, presumably because of the high natural immunity of rabbits to staphylococci. (TCO)« less
... Restlessness, anxiety or agitation Drowsiness or fatigue Dizziness, light-headedness or faintness Profuse sweating, moist skin Irritability Thirst Rapid pulse Rapid, weak breathing Enlarged pupils Nausea or vomiting Blue tinge to lips or fingernails (or gray in ...
... to anything that can irritate your skin. Wear cotton gloves under plastic gloves to soak up sweat ... make your eczema worse. Wear clothes made of cotton or a cotton blend. Wool and some synthetic ...
Masuoka, Hiromu; Morimoto, Naoki; Sakamoto, Michiharu; Ogino, Shuichi; Suzuki, Shigehiko
2016-06-01
Nicotine has been reported to prolong the wound healing; however, we showed that the topical application of 10(-4) M nicotine promoted murine wound healing. The objective of this study was to explore the wound healing effects of nicotine in combination with collagen scaffold using skin defects in rabbit. Three full-thickness skin defects 8 mm in diameter were made on the rabbit auricle. Artificial dermis was applied to the defects, and 10 μl of nicotine solution (10(-5), 10(-4), and10(-3) M), bFGF solution (0.5 μg/10 μl), and both bFGF and 10(-4) M nicotine solutions were injected into the artificial dermis once daily for 7 days. Rabbits were sacrificed on day 10, 15, or 20, and the wound healing process was evaluated. bFGF was superior in the formation of the dermis-like tissue and capillaries. In nicotine groups, the epithelial length and the dermis-like tissue formations in the 10(-4) M group were superior, in contrast, those were inhibited in the 10(-3) M group. The synergistic effect of bFGF and 10(-4) M nicotine was not confirmed. This study suggests that the topical application of 10(-4) M nicotine promoted wound healing in rabbit, but the effect was not apparent compared with murine models.
The effect of adhesive dressing edges on cutaneous irritancy and skin barrier function.
Dykes, P J
2007-03-01
To assess the effect of repeated application and removal of adhesive edges from wound-care products on cutaneous irritancy and barrier function in normal volunteer subjects. This was a study using a 'repeat-insult patch test'. Adhesive edges from six commonly used wound-care products were applied continuously to the same site (six applications over a 14-day period) in 30 normal volunteer subjects. The test sites were assessed clinically before product reapplication using established ranking scales for cutaneous erythema. The cumulative irritancy score (CIS) for each test site was determined by adding the erythema scores at days 3, 5, 8, 10, 12 and 15. At the study end the barrier function of each test site was assessed by measuring transepidermal water loss (TEWL). The CIS showed that the products fall into two distinct groups, with Mepilex, Tielle and Allevyn giving low scores and Biatain, Comfeel and DuoDERM higher scores. Statistical analysis indicated significant differences (p < 0.05) between Mepilex and Biatain, Mepilex and Comfeel, Mepilex and DuoDERM, Tielle and Biatain, Allevyn and Biatain. The mean TEWL values also indicated that the products fall into two distinct groups: Mepilex, Tielle and Allevyn with low mean values close to that of normal adjacent back skin and Biatain, Comfeel and DuoDERM with much higher mean values. Statistical analysis indicated that Mepilex, Tielle and Allevyn were not significantly different from normal skin (p < 0.05), whereas Biatain, Comfeel and DuoDERM were significantly higher than normal skin and the other products tested. The results show clear differences between products; the clinical scores and TEWL measurements indicate that the products fall into two distinct groups. This novel approach seems able to discriminate between adhesive borders and may be useful during product development and in selecting products for clinical trials.
Ehling, G; Hecht, M; Heusener, A; Huesler, J; Gamer, A O; van Loveren, H; Maurer, Th; Riecke, K; Ullmann, L; Ulrich, P; Vandebriel, R; Vohr, H-W
2005-08-15
The new OECD guideline 429 (skin sensitization: local lymph node assay) is based upon a protocol, which utilises the incorporation of radioactivity into DNA as a measure for cell proliferation in vivo. The guideline also enables the use of alternative endpoints in order to assess draining lymph node (LN) cell proliferation. Here we describe the first round of an inter-laboratory validation of alternative endpoints in the LLNA conducted in seven laboratories. The validation study was managed and supervised by the Swiss Agency for Therapeutic Products, Swissmedic. Statistical analyses of all data were performed by an independent centre at the University of Bern, Department of Statistics. Ear-draining, LN weight and cell count were used to assess proliferation instead of radioactive labeling of lymph node cells. In addition, the acute inflammatory skin reaction was measured by ear swelling and weight of circular biopsies of the ears to identify skin irritating properties of the test items. Hexylcinnamaldehyde (HCA) and three blinded test items were applied to female, 8--10 weeks old NMRI and BALB/c mice. Results were sent via the independent study coordinator to the statistician. The results of this first round showed that the alternative endpoints of the LLNA are sensitive and robust parameters. The use of ear weights added an important parameter assessing the skin irritation potential, which supports the differentiation of pure irritative from contact allergenic potential. There were absolute no discrepancies between the categorisation of the three test substances A--C determined by each single participating laboratories. The results highlighted also that many parameters do have an impact on the strength of the responses. Therefore, such parameters have to be taken into consideration for the categorisation of compounds due to their relative sensitizing potencies.
Lee, Miri; Nam, Ki Taek; Kim, Jungah; Lim, Song E; Yeon, Sang Hyeon; Lee, Buhyun; Lee, Joo Young; Lim, Kyung-Min
2017-10-01
Coal-tar dyes in cosmetics may elicit adverse effects in the skin and eyes. Countries, like the US, have banned the use of coal-tar dyes in cosmetics for the eye area due to the potential for ocular irritation. We evaluated the eye irritation potential of 15 coal-tar dyes permitted as cosmetic ingredients in reconstructed human cornea-like epithelium (RhCEs [EpiOcular™ and MCTT HCE™]) tests and the short time exposure (STE) test. Eosin YS, phloxine B, tetrachlorotetrabromofluorescein, and tetrabromofluorescein were identified as irritants in RhCEs; dibromofluorescein and uranine yielded discrepant results. STE enabled further classification in accordance with the UN Globally Harmonized System of Classification and Labelling of Chemicals, as follows: eosin YS as Cat 2; phloxine B, Cat 1; and tetrachlorotetrabromofluorescein and tetrabromofluorescein, Cat 1/2. STE indicated dibromofluorescein (irritant in EpiOcular™) and uranine (irritant in MCTT HCE™) as No Cat, resulting in the classification of "No prediction can be made." based on bottom-up approach with each model. These results demonstrated that in vitro eye irritation tests can be utilized to evaluate the potential ocular irritancy of cosmetic ingredients and provide significant evidence with which to determine whether precautions should be given for the use of coal-tar dyes in cosmetics or other substances applied to the eye area. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ljubojević Hadžavdić, Suzana; Pustišek, Nives; Žužul, Kristina; Švigir, Alen
2018-06-01
Contact allergies are common cause of eczema in all age groups and are one of the most common causes of occupational disability. Contact dermatitis (CD) can be divided into irritant and allergic contact dermatitis. Distinguishing between irritant and allergic triggers of CD by clinical and histologic examinations can be challenging. The approach to patients with CD should consist of a detailed (work and leisure) history, skin examination, patch tests with allergens based on history, physical examination, education on materials that contain the allergen and adequate therapy and prevention.
Fournier, Jean-François; Bouix-Peter, Claire; Duvert, Denis; Luzy, Anne-Pascale; Ouvry, Gilles
2018-04-12
Phototoxicity occurs when UV irradiation causes otherwise benign compounds to become irritant, sensitizers, or even genotoxic. This toxicity is particularly a concern after topical application and in dermatological programs where skin irritation can be incompatible with the desired therapeutic outcome. This brief article establishes that the intrinsic property forecast index (iPFI) can be used to evaluate the probability of a compound being phototoxic and gives medicinal chemists a practical tool to handle this liability.
Resident Rounds: Part III - Case Report: Betel Quid Induced Irritant Contact Dermatitis of the Hand.
Mathieu, Regine J; Cheraghi, Nikoo; Russo, Marian A
2016-06-01
Betel quid is a drug used in Far East Asia, India, and the South Pacific. The habit of betel quid chewing is widely reported to cause oral cancer and tooth and gum disease. However, skin disease due to betel quid use is underreported. We report a case of irritant contact dermatitis to betel quid components in a 35-year-old male betel quid user who presented for evaluation of a persistent rash on his fingertips.
Iontophoretic and Microneedle Mediated Transdermal Delivery of Glycopyrrolate
Gujjar, Meera; Banga, Ajay K.
2014-01-01
Purpose: The objective of this study was to investigate the use of iontophoresis, soluble microneedles and their combination for the transdermal delivery of glycopyrrolate. Methods: In vitro permeation was tested using full thickness porcine ear skin mounted onto Franz diffusion cells. Iontophoresis (0.5 mA/cm2) was done for 4 h using Ag/AgCl electrodes. For microneedles, three line array (27 needles/line) of maltose microneedles were used to microporate the skin prior to mounting. Pore uniformity was determined by taking fluorescent images of distribution of calcein into pores and processing the images using an image analysis tool, which measured the fluorescent intensity in and around each pore to provide a pore permeability index (PPI). The donor chamber contained 500 µL of a 1 mg/mL solution of glycopyrrolate, and the receptor chamber contained 5 mL of 50 mM NaCl in deionized water. Samples were collected at predetermined time points over a period of 24 h and analyzed by HPLC. Skin irritation testing was performed with a 3D cell culture kit of human skin. MTT assay determined cell viability; viability less than 50% was considered irritant. Results: A control experiment which investigated passive permeation of glycopyrrolate delivered an average cumulative amount of 24.92 ± 1.77 µg/cm2 at 24 h, while microneedle pretreatment increased permeability to 46.54 ± 6.9 µg/cm2. Both iontophoresis (158.53 ± 17.50 µg/cm2) and a combination of iontophoresis and microneedles (182.43 ± 20.06 µg/ cm2) significantly increased delivery compared to passive and microneedles alone. Glycopyrrolate solution was found to be nonirritant with cell viability of 70.4% ± 5.03%. Conclusion: Iontophoresis and a combination of iontophoresis with microneedle pretreatment can be effectively used to enhance the transdermal delivery of glycopyrrolate. Glycopyrrolate was found to be non-irritant to skin. PMID:25533309
Miura, Tomoe; Takada, Akiyoshi; Ooe, Masahiko
2012-08-01
Topical tretinoin [all-trans-retinoic acid (RA)] currently is widely used to treat photoaged skin. However, undesirable side effects such as erythema, irritation, and scaling are unavoidable and limit the use of tretinoin. To address these issues, the authors developed the tretinoin cyclodextrin complex (RA/CyD), which is tretinoin encapsulated by cyclodextrin. Cyclodextrins are cyclic oligosaccharides commonly used in food additives and fabric fresheners. This study aimed to evaluate the antiwrinkle effect of RA/CyD and alleviation of the side effects compared with RA treatment alone. In this study, 12 photoaged patients completed an 8 week study using RA and RA/CyD in a double-blind manner. Before and after the treatment, the patients' evaluations, wrinkle scores, skin elasticity, and wrinkle area measurement using skin replica were evaluated. Three men were recruited for histologic analysis. The patients reported that undesirable irritant reactions were more moderate with RA/CyD than with RA. In the assessment of wrinkle scores, skin elasticity, and wrinkle area measurement, RA/CyD demonstrated an antiwrinkle effect statistically equal to that of RA. In histology, both RA/CyD and RA demonstrated epidermal hyperplasia. In immunohistochemistry, inflammation induced by RA/CyD was more moderate than that induced by RA. The findings show that RA and RA/CyD result in the equivalent clinical improvement for patients with photoaging. The use of RA/CyD overcomes the drawbacks of RA while possessing equal effect. It is expected that CyD will broaden tretinoin treatment. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.springer.com/00266.
Highly efficient and compatible shampoo for use after hair transplant
Schweiger, Dorothea; Schoelermann, Andrea M; Filbry, Alexander; Hamann, Tina; Moser, Claudia; Rippke, Frank
2015-01-01
Background Sensitive or hyperreactive skin is a common condition defined by prickling, burning, pain, and pruritus. Although this skin problem was initially described on the face, the scalp is often affected. A sensitive scalp can react with irritation to harsh surfactants or other additives which are often present in shampoos. For this reason, we developed a new rinse-off hypertolerant shampoo specifically designed for the hypersensitive and problematic scalp. Methods The shampoo formulation is based on an extremely mild surfactant system and contains bisabolol, an anti-irritant and anti-inflammatory ingredient of chamomile. The shampoo is free of additives such as perfumes, silicones, colorants, parabens, paraffins, and betaine. Since skin can remain in a hyperreactive state after wounding, the status after hair transplantation was chosen as a model system to test the shampoo. Scalp condition and compatibility of each volunteer were analyzed by a plastic surgeon directly after hair transplant and after stitch removal. The plastic surgeons also rated whether they would recommend the further use of the test shampoo. Additionally, volunteers completed a self-assessment questionnaire. Results Following hair transplantation, regular use of the shampoo resulted in a significant reduction in the extent of scabbing and erythema. This was confirmed by dermatological scalp examinations performed by the plastic surgeon as well as in volunteers’ self-assessments. The plastic surgeon highly recommended the further use of the test shampoo after hair transplant to all study participants. Conclusion Application of the test shampoo demonstrated excellent skin compatibility and product efficacy after hair transplant. The test shampoo significantly reduced the extent of scabs and erythema. Therefore, the shampoo is ideally suited for use after hair transplantation and for the treatment of sensitive scalp. The excellent skin compatibility is because of the mild surfactant system, the calming ingredient bisabolol, and the absence of potentially irritating ingredients. PMID:26229498
Khan, N R; Khan, G M; Wahab, A; Khan, A R; Hussain, A; Nawaz, A; Akhlaq, M
2011-11-01
The aim of the present study was to investigate the transdermal permeation enhancing capability of turpentine oil for ibuprofen from hydrogels. Ibuprofen 1% w/v hydrogels were developed with carboxypolymethylene with and without turpentine oil. Turpentine oil was incorporated in increasing concentrations, i.e. 0.5, 1, 1.5, 2, 2.5 and 3% of the total gel formulation, and its permeation enhancing effect was examined. Gels were examined physically for pH, viscosity, spreadability, extrudability, smoothness and appearance. To study the in vitro and ex vivo permeation potential of formulated gels, permeation studies were performed with a Franz diffusion cell using cellulose membrane and excised rabbit abdominal skin. Ibuprofen hydrogel with 3% turpentine oil showed a maximum flux of 10.87 mg/cm2/h across artificial skin and 17.26 mg/cm2/h across rabbit abdominal skin.
NASA Astrophysics Data System (ADS)
Popp, A.; Wendel, M.; Knels, L.; Knuschke, P.; Mehner, M.; Koch, T.; Boller, D.; Koch, P.; Koch, E.
2005-08-01
A compact common path Fourier domain optical coherence tomography (FD-OCT) system based on a broadband superluminescence diode is used for biomedical imaging. The epidermal thickening of human skin after exposure to ultraviolet radiation is measured to proof the feasibility of FD-OCT for future substitution of invasive biopsies in a long term study on natural UV skin protection. The FD-OCT system is also used for imaging lung parenchyma. FD-OCT images of a formalin fixated lung show the same alveolar structure as scanning electron microscopy images. In the ventilated and blood-free perfused isolated rabbit lung FD-OCT is used for real-time cross-sectional image capture of alveolar mechanics throughout tidal ventilation. The alveolar mechanics changing from alternating recruitment-derecruitment at zero positive end-expiratory pressure (PEEP) to persistent recruitment after applying a PEEP of 5 cm H2O is observed in the OCT images.
... long time. True False False: This is called contact dermatitis, which is often due to nickel. Question 9 ... dermatitis. True False True: This is called Irritant contact dermatitis which is more common than allergic contact dermatitis. ...
Management of Central Venous Access Device-Associated Skin Impairment: An Evidence-Based Algorithm.
Broadhurst, Daphne; Moureau, Nancy; Ullman, Amanda J
Patients relying on central venous access devices (CVADs) for treatment are frequently complex. Many have multiple comorbid conditions, including renal impairment, nutritional deficiencies, hematologic disorders, or cancer. These conditions can impair the skin surrounding the CVAD insertion site, resulting in an increased likelihood of skin damage when standard CVAD management practices are employed. Supported by the World Congress of Vascular Access (WoCoVA), developed an evidence- and consensus-based algorithm to improve CVAD-associated skin impairment (CASI) identification and diagnosis, guide clinical decision-making, and improve clinician confidence in managing CASI. A scoping review of relevant literature surrounding CASI management was undertaken March 2014, and results were distributed to an international advisory panel. A CASI algorithm was developed by an international advisory panel of clinicians with expertise in wounds, vascular access, pediatrics, geriatric care, home care, intensive care, infection control and acute care, using a 2-phase, modified Delphi technique. The algorithm focuses on identification and treatment of skin injury, exit site infection, noninfectious exudate, and skin irritation/contact dermatitis. It comprised 3 domains: assessment, skin protection, and patient comfort. External validation of the algorithm was achieved by prospective pre- and posttest design, using clinical scenarios and self-reported clinician confidence (Likert scale), and incorporating algorithm feasibility and face validity endpoints. The CASI algorithm was found to significantly increase participants' confidence in the assessment and management of skin injury (P = .002), skin irritation/contact dermatitis (P = .001), and noninfectious exudate (P < .01). A majority of participants reported the algorithm as easy to understand (24/25; 96%), containing all necessary information (24/25; 96%). Twenty-four of 25 (96%) stated that they would recommend the tool to guide management of CASI.
NASA Astrophysics Data System (ADS)
kazem Koohi, Mohammad; Hejazy, Marzie; Asadi, Farzad; Asadian, Peyman
2011-07-01
The purpose of this study is to evaluate the dermal toxicity (Irritation/Corrosion) of three sizes of nanosilver particles (10, 20 and 30 nm) during 3 min, 1 and 4 hours according to the OECD/OCDE guideline Histopathological effects in secondary organs from liver, kidney, heart, spleen and brain 14 day post dermal administration are also reported. 10 and 20 nm Ag nanoparticles treated group showed well defined dermal erythema and oedema. Histopathological findings of 10 and 20 nm (4 hours exposure) on 14-day post dermal administration showed hyperkeratosis, acanthosis, hair-filled follicles and papillomatosis in an irregular epidermis, fibrosis, hyperemia, erythema, intracellular oedema and hyalinisation of collagen in dermis of skin. Liver revealed midzonal and periacinar necrosis, portal mononuclear infiltration, liver fatty change, liver congestion and hyperemic central vein. Splenic red pulp congestion and white pulp hyperreactivity, splenic trabeculae and sinusoidal congestion and hyaline change were found in spleen. Fatty degeneration in some cardiovascular cells and subendocardial hemorrhage without inflammation was perceived. Picnotic appearance of pyramidal neurons in the brain cortex, gliosis and mild perineuronal oedema ischemic cell change and hyperemic meninges was observed in brain. Our research concluded that dermal exposure to lesser sizes of silver nanoparticles is more disastrous than greater ones.
Health Concerns about Spray Polyurethane Foam
Exposures to SPF's key ingredient, isocyanates and other SPF chemicals in vapors, aerosols, and dust created during and after installation, can cause: asthma, sensitization, lung damage, other respiratory and breathing problems, skin and eye irritation.
... causing: Pain Irritation Sores Problems finding shoes that fit Skin infections Surgery may not be advised if: Treatment with paddings and strapping works You can still straighten your toe Changing to different shoe types can alleviate symptoms
77 FR 28270 - Fluxapyroxad; Pesticide Tolerances
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-14
..., dermal and inhalation routes, is not irritating to the eyes and skin, and is not a dermal sensitizer. The... Grains, Legume Vegetables (Succulent and Dry), Oil Seed Crops (Canola and Sunflower), Peanuts, Pome Fruit...
MRSA Prevention Information and Advice for Athletes
... at sites covered by body hair or where uniforms or equipment cause skin irritation or increased rubbing. ... not share bar soap or towels. Wash your uniform and clothing after each use. Follow the clothing ...
Antibacterials in Household Products
... it irritates their skin. ♦ Build-up in the environment: Triclosan is slow to degrade and residue build-up ... plasma. ♦ Antibacterial resistance: Residue-producing antibacterials, most ... Some bacteria are naturally resistant to triclosan. ♦ Immune ...
Over-the-Counter Acne Products: What Works and Why
... ingredient helps prevent pores from becoming plugged. OTC salicylic acid products are available in strengths from 0.5 to 5 percent. Possible side effects include mild stinging and skin irritation. Alpha hydroxy ...
Competition between skin-sensitizing chemicals in the mouse
Wallington, T. B.; Jones, J. Verrier
1974-01-01
The skin contact sensitivity responses to picryl chloride in CBA mice can be reduced by prior sensitization with oxazolone. Initial experiments showed this reduction to be significant when the interval between skin paintings was 7 days. In further experiments to study the time course of this effect, the depression was found to be maximal when the interval between skin paintings was between 3 and 7 days. Prior painting with a non-immunogenic chemical irritant, oil of turpentine, did not depress responses to picryl chloride. The relation of this phenomenon to antigenic competition in antibody production is discussed. PMID:4851120
Alves, Eloísa Nunes; Presgrave, Rosaura de Farias; Presgrave, Octávio Augusto França; Sabagh, Fernanda Peres; de Freitas, João Carlos Borges Rolim; Corrado, Alexandre P
2008-07-01
We examined the correlation between results obtained from the in vivo Draize test for ocular irritation and in vitro results obtained from the sheep red blood cell (RBC) haemolytic assay, which assesses haemolysis and protein denaturation in erythrocytes, induced by cosmetic products. We sought to validate the haemolytic assay as a preliminary test for identifying highly-irritative products, and also to evaluate the in vitro test as alternative assay for replacement of the in vivo test. In vitro and in vivo analyses were carried out on 19 cosmetic products, in order to correlate the lesions in the ocular structures with three in vitro parameters: (i) the extent of haemolysis (H50); (ii) the protein denaturation index (DI); and (iii) the H50/DI ratio, which reflects the irritation potential (IP). There was significant correlation between maximum average scores (MAS) and the parameters determined in vitro (r = 0.752-0.764). These results indicate that the RBC assay is a useful and rapid test for use as a screening method to assess the IP of cosmetic products, and for predicting the IP value with a high level of concordance (94.7%). The assay showed high sensitivity and specificity rates of 91.6% and 100%, respectively.
Tretinoin-loaded liposomal formulations: from lab to comparative clinical study in acne patients.
Rahman, Salwa Abdel; Abdelmalak, Nevine Shawky; Badawi, Alia; Elbayoumy, Tahany; Sabry, Nermeen; El Ramly, Amany
2016-05-01
Topical tretinoin is the most commonly used retinoid for acne. However, its irritative potential on the applied area and the barrier properties of the stratum corneum limit its use. The objective of the present study was to formulate tretinoin liposomal gel to obtain a formula with lower skin irritation potential and greater clinical effect. A statistical 2(4) factorial design was adopted. Sixteen formulae prepared and were properly evaluated. A candidate formula (F13G) prepared with 0.025% tretinoin, phospholipid- cholesterol-dicetylphosphate (9:1:0.01) and incorporated in 1% carbopol gel was selected for skin irritation test. Clinical study was conducted on acne patients and compared to marketed product. All liposomes formulations were spherical in shape. The addition of cholesterol in the film hydration method significantly decreased the vesicle size, and increased the percentage of incorporation efficiency at (p < 0.05). The presence of dicetylphosphate significantly increased drug release but did not affect the percentage of incorporation efficiency and vesicle size. The results of the clinical study in acne patients revealed that F13G showed significantly higher efficacy when compared to marketed product (p < 0.05).
Jungersted, Jakob Mutanu; Høgh, Julie K; Hellegren, Lars I; Jemec, Gregor B E; Agner, Tove
2011-05-01
The skin barrier, located in the stratum corneum, is influenced mainly by the lipid and protein composition of this layer. In eczematous diseases impairment of the skin barrier is thought to be of prime importance. Topical anti-inflammatory drugs and emollients are the most widely used eczema treatments. The aim of this study was to examine the effects of topically applied corticosteroid, tacrolimus and emollient on stratum corneum lipids and barrier parameters. Nineteen healthy volunteers participated in the study. Both forearms of the subjects were divided into four areas, which were treated twice daily for one week with betamethasone, tacrolimus, emollient, or left untreated, respectively. After one week each area was challenged with a 24 h sodium lauryl sulphate patch test. The lipids were collected using the cyanoacrylate method and evaluated by high performance thin layer chromatography. For evaluation of the skin barrier, transepidermal water loss, erythema and electrical capacitance were measured. The ceramide/cholesterol ratio was increased in betamethasone- (p = 0.008) and tacrolimus-treated (p = 0.025) skin compared with emollient-treated skin. No differences in ceramide subgroups were found between treatment regimes. Pretreatment with betamethasone (p = 0.01) or with tacrolimus (p = 0.001) causes a decreased inflammatory response to sodium lauryl sulphate compared with emollient. In conclusion, treatment with betamethasone and tacrolimus has a positive effect on the ceramide/cholesterol ratio and susceptibility to irritant reaction compared with an emollient.
Dahlqvist, M; Lagerstrand, L; Nilsen, A
1994-01-01
Acute temporary changes in lung function may be of use as a biological exposure indicator. However, studies of humans occupationally exposed to complex airborne irritants are often expensive and time demanding. Therefore, an animal model could be a valuable complement. A rabbit model has been evaluated where transfer factor was measured twice during the same day, and with the rabbit awake and available for exposure, in between. Anaesthesia and intubation in 22 rabbits (2.6 [0.2] kg [Mean (SD)]) were immediately followed by two measurements of transfer factor and alveolar volume. Transfer factor was estimated by the single breath CO-technique used in humans. The samples were analysed for CO and He on a gas chromatograph. After one pair of measurements the rabbit was allowed to wake up and after 5 h the duplicate measurements were repeated. The mean values of transfer factor, alveolar volume and transfer constant were 0.50 (0.09) mmol min-1 kPa-1, 127 (8) ml and 3.9 (0.6) mmol min-1 kPa-1 l-1, respectively. The intraindividual coefficients of variation were 7.3%, 5.3% and 6.7%, respectively. Five hours later when the duplicate measurements were repeated, transfer factor, alveolar volume and transfer constant were unchanged still. The results suggest that relatively small changes in transfer factor may be detected without losing power, and thus that this model could be used as a biological exposure indicator.
1988-12-01
MSC DTICELECTE MAMMALIN TOXICOLOGY BRANCH 2 7 EB l DIVISION OF ToXIcoLoGY December, 1988 Toxicology Seris- 244 LETTERMAN ARMY INSTITUTE OF RESEARCH ...endorsement or approval of the use of such items. In conducting the research described in this report, the investigation adhered to the "Guide for the Care...Laboratory Animal Resources, National Research Council. This material has been reviewed by Letterman Army Institute of Research and there is no objection
Skin care in nursing: A critical discussion of nursing practice and research.
Kottner, Jan; Surber, Christian
2016-09-01
Skin (self-)care is part of human life from birth until death. Today many different skin care practices, preferences, traditions and routines exist in parallel. In addition, preventive and therapeutic skin care is delivered in nursing and healthcare by formal and informal caregivers. The aim of this contribution is a critical discussion about skin care in the context of professional nursing practice. An explicit skin assessment using accurate diagnostic statements is needed for clinical decision making. Special attention should be paid on high risk skin areas, which may be either too dry or too moist. From a safety perspective the protection and maintenance of skin integrity should have the highest priority. Skin cleansing is the removal of unwanted substances from the skin surface. Despite cleansing efficacy soap, other surfactants and water will inevitably always result in the destruction of the skin barrier. Thousands of products are available to hydrate, moisturize, protect and restore skin properties dependent upon their formulation and the concentration of ingredients. These products intended to left in contact with skin exhibit several actions on and in the skin interfering with skin biology. Unwanted side effects include hyper-hydration and disorganization of lipid bilayers in the stratum corneum, a dysfunctional barrier, increased susceptibility to irritants and allergies, and increases of skin surface pH. Where the skin barrier is impaired appropriate interventions, e.g. apply lipophilic products in sufficient quantity to treat dry skin or protect the skin from exposure to irritants should be provided. A key statement of this contribution is: every skin care activity matters. Every time something is placed on the skin, a functional and structural response is provoked. This response can be either desired or undesired, beneficial or harmful. The choice of all skin care interventions in nursing and healthcare practice must be based on an accurate assessment of the skin and concomitant health conditions and on a clearly defined outcome. A standardized skin care and skin care product language is needed for researchers planning and conducting clinical trials, for reviewers doing systematic reviews and evidence-base summaries, for nurses and other healthcare workers to deliver evidence-based and safe skin care. Copyright © 2016. Published by Elsevier Ltd.
Facchini, Gustavo; Eberlin, Samara; Clerici, Stefano Piatto; Alves Pinheiro, Ana Lucia Tabarini; Costa, Adilson
2017-12-01
Unwanted side effects such as dryness, hypersensitivity, and cutaneous photosensitivity are challenge for adherence and therapeutical success for patients using treatments for inflammatory and allergic skin response. In this study, we compared the effects of two dermatological formulations, which are used in inflammatory and/or allergic skin conditions: dexchlorpheniramine maleate (DCP; 10 mg/g) and promethazine (PTZ; 20 mg/g). We evaluated both formulations for phototoxicity potential, skin irritation, anti-inflammatory and antihistaminic abilities, and skin barrier repair in vitro and ex vivo using the standard OECD test guideline n° 432, the ECVAM protocol n° 78, and cultured skin explants from a healthy patient. Ultraviolet A was chosen as exogenous agent to induce allergic and inflammatory response. Both PTZ and DCP promoted increases in interleukin-1 (IL-1) synthesis in response to ultraviolet A (UVA) radiation compared to control. However, the increase observed with PTZ was significantly greater than the DCP, indicating that the latter has a lower irritant potential. DCP also demonstrated a protective effect on UVA-induced leukotriene B4 and nuclear factor kappa B (NF-κB) synthesis. Conversely, PTZ demonstrates more robust UVA antihistaminic activity. Likewise, PTZ promoted a significantly greater increase in the production of involucrin and keratin 14, both associated with protective skin barrier property. In conclusion, these data suggest possible diverging UVA response mechanisms of DCP and PTZ, which gives greater insight into the contrasting photosensitizing potential between DCP and PTZ observed in the patients. © 2017 Wiley Periodicals, Inc.
Sharma, Gajanand; Dhankar, Geeta; Thakur, Kanika; Raza, Kaisar; Katare, O P
2016-10-01
Benzyl benzoate (BB) is one of the oldest drugs used for the treatment of scabies and is recommended as the "first-line intervention" for the cost-effective treatment of the disease. Though a promising candidate, its application is reported to be associated with irritation of the skin and eye, resulting in poor patient compliance. Hence, the present study aims to develop BB-loaded topical microemulsion for the safer and effective delivery of BB. Pseudo-ternary phase diagrams with BB as the oily phase itself, along with Tween 80 as surfactant, and mixture of phospholipid and ethanol as the co-surfactant along with aqueous solution as the external phase were constructed and various compositions were formulated. The optimized formulation was characterized for particle-size, zeta-potential, drug-content, globule-morphology pH, and refractive-index, whereas evaluated for skin permeation, retention, compliance, and dermatokinetics. The nanosized formulation offered threefold higher drug permeation vis-a-vis plain drug solution across LACA mice abdominal skin. The drug retention of the selected formulation was nearly twice of that from the marketed product, assuring depot formulation and sustained release. The skin histopathology revealed the non-irritant nature of the formulation, as no changes in the normal skin histology were observed. The dermatokinetic studies confirmed better permeation and enhanced skin bioavailability of BB to epidermis as well as dermis vis-à-vis the conventional product. The results indicate that the developed lipid-based microemulsion hydrogel can alleviate the concerns associated with BB and can provide a better and safer delivery option in substantial amounts to various skin layers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akram, Muhammad
Impaired immune responses in skin play a pivotal role in the development and progression of chemical-associated inflammatory skin disorders. In this study, we synthesized new flavonoid derivatives from macakurzin C, and identified in vitro and in vivo efficacy of a potent anti-inflammatory flavonoid, Compound 14 (CPD 14), with its underlying mechanisms. In lipopolysaccharide (LPS)-stimulated murine macrophages and IFN-γ/TNF-α-stimulated human keratinocytes, CPD 14 significantly inhibited the release of inflammatory mediators including nitric oxide (NO), prostaglandins, and cytokines (IC{sub 50} for NO inhibition in macrophages: 4.61 μM). Attenuated NF-κB signaling and activated Nrf2/HO-1 pathway were responsible for the anti-inflammatory effects of CPDmore » 14. The in vivo relevance was examined in phorbol 12-myristate 13-acetate (TPA)-induced acute skin inflammation and oxazolone-induced atopic dermatitis models. Topically applied CPD 14 significantly protected both irritation- and sensitization-associated skin inflammation by suppressing the expression of inflammatory mediators. In summary, we demonstrated that a newly synthesized flavonoid, CPD 14, has potent inhibitory effects on skin inflammation, suggesting it is a potential therapeutic candidate to treat skin disorders associated with excessive inflammation. - Highlights: • An anti-inflammatory flavonoid CPD 14 was newly synthesized from macakurzin C. • CPD 14 potently inhibited inflammatory reaction in keratinocytes and macrophages. • Dermal toxicity by irritation or sensitization in rats was protected by CPD 14. • Attenuated NF-κB and activated Nrf2/HO-1 were main mechanisms of CPD 14 action.« less
Seals, Shanna L; Kearney, Michael; Del Piero, Fabio; Hammerberg, Bruce; Pucheu-Haston, Cherie M
2014-05-15
Immunoglobulin-E (IgE) mediated reactions can be induced by intradermal injection of anti-IgE antibodies in both humans and dogs. These reactions grossly and histologically mimic changes seen in naturally occurring allergic dermatitis in these species. Similar studies have not been conducted in the cat. Purified polyclonal rabbit-origin IgG specific for canine IgE (anti-IgE) and rabbit immunoglobulin G (IgG) were injected intradermally in 7 non-allergic laboratory colony cats. Wheal measurements were obtained and biopsies collected before injection and at injection sites after 20 min, 6, 24, and 48 h. Injection of anti-IgE induced an immediate wheal response which was significantly larger than that seen after injection of rabbit IgG. Anti-IgE injected skin was also significantly thicker than IgG-injected skin. This corresponded with a significant increase in number of visibly degranulated mast cells in anti-IgE samples when compared to IgG samples. Injection of anti-IgE was associated with the rapid recruitment of inflammatory cells to the injected dermis. The number of inflammatory cells and mononuclear cells were significantly elevated after the injection of anti-IgE when compared to IgG-injected skin. Both eosinophils and neutrophils were significantly increased in anti-IgE samples relative to IgG, although neutrophils were only transiently increased. The high eosinophil and relatively low neutrophil cell counts in these samples were consistent with previously documented histologic features of naturally occurring feline allergic skin disease. Immunohistochemistry identified a significantly overall increased CD1a(+) cells after the intradermal injection of anti-IgE when compared to IgG and non-injected skin. CD3(+), CD8(+) and CD4(+) were also significantly increased overall in anti-IgE injected skin relative to IgG injected skin. These data document the gross and cellular response to injection of anti-IgE in the skin of healthy, non-allergic cats and support a possible role for IgE in the development of feline allergic dermatitis. Copyright © 2014 Elsevier B.V. All rights reserved.
In Vitro Dermal Safety Assessment of Silver Nanowires after Acute Exposure: Tissue vs. Cell Models
Grichine, Alexei; Rachidi, Walid; Charlet, Laurent
2018-01-01
Silver nanowires (AgNW) are attractive materials that are anticipated to be incorporated into numerous consumer products such as textiles, touchscreen display, and medical devices that could be in direct contact with skin. There are very few studies on the cellular toxicity of AgNW and no studies that have specifically evaluated the potential toxicity from dermal exposure. To address this question, we investigated the dermal toxicity after acute exposure of polymer-coated AgNW with two sizes using two models, human primary keratinocytes and human reconstructed epidermis. In keratinocytes, AgNW are rapidly and massively internalized inside cells leading to dose-dependent cytotoxicity that was not due to Ag+ release. Analysing our data with different dose metrics, we propose that the number of NW is the most appropriate dose-metric for studies of AgNW toxicity. In reconstructed epidermis, the results of a standard in vitro skin irritation assay classified AgNW as non-irritant to skin and we found no evidence of penetration into the deeper layer of the epidermis. The findings show that healthy and intact epidermis provides an effective barrier for AgNW, although the study does not address potential transport through follicles or injured skin. The combined cell and tissue model approach used here is likely to provide an important methodology for assessing the risks for skin exposure to AgNW from consumer products. PMID:29641466
In Vitro Dermal Safety Assessment of Silver Nanowires after Acute Exposure: Tissue vs. Cell Models.
Lehmann, Sylvia G; Gilbert, Benjamin; Maffeis, Thierry Gg; Grichine, Alexei; Pignot-Paintrand, Isabelle; Clavaguera, Simon; Rachidi, Walid; Seve, Michel; Charlet, Laurent
2018-04-11
Silver nanowires (AgNW) are attractive materials that are anticipated to be incorporated into numerous consumer products such as textiles, touchscreen display, and medical devices that could be in direct contact with skin. There are very few studies on the cellular toxicity of AgNW and no studies that have specifically evaluated the potential toxicity from dermal exposure. To address this question, we investigated the dermal toxicity after acute exposure of polymer-coated AgNW with two sizes using two models, human primary keratinocytes and human reconstructed epidermis. In keratinocytes, AgNW are rapidly and massively internalized inside cells leading to dose-dependent cytotoxicity that was not due to Ag⁺ release. Analysing our data with different dose metrics, we propose that the number of NW is the most appropriate dose-metric for studies of AgNW toxicity. In reconstructed epidermis, the results of a standard in vitro skin irritation assay classified AgNW as non-irritant to skin and we found no evidence of penetration into the deeper layer of the epidermis. The findings show that healthy and intact epidermis provides an effective barrier for AgNW, although the study does not address potential transport through follicles or injured skin. The combined cell and tissue model approach used here is likely to provide an important methodology for assessing the risks for skin exposure to AgNW from consumer products.
Development of Non-Invasive Deep Tissue pH Sensor.
1995-10-01
gas samples were used to adjust ventilation during the experiment to maintain proper acid-base balance. First, the right latissimus dorsi muscle flap...of skin approximately 1 inch by 2 inches was cut from the rabbit from the area which was over the latissimus dorsi muscle. The skin was shaved of fur
Gelatin coated electrodes allow prolonged bioelectronic measurements
NASA Technical Reports Server (NTRS)
1966-01-01
Silver electrodes treated with an anodizing electrolyte containing gelatin are used for long term monitoring of bioelectronic potentials in humans. The electrodes do not interact with perspiration, cause skin irritation, or promote the growth of bacteria.
Skin interaction with absorbent hygiene products.
Runeman, Bo
2008-01-01
Skin problems due to the use of absorbent hygiene products, such as diapers, incontinence pads, and feminine sanitary articles, are mostly due to climate or chafing discomfort. If these conditions are allowed to prevail, these may develop into an irritant contact dermatitis and eventually superficial skin infections. Skin humidity and aging skin are among the most significant predisposing and aggravating factors for dermatitis development. Improved product design features are believed to explain the decline in observed diaper dermatitis among infants. Where adult incontinence-related skin problems are concerned, it is very important to apply a holistic perspective to understand the influences due to the individual's incontinence level and skin condition, as well as the hygiene and skin care measures provided. Individuals with frail, sensitive skin or with skin diseases may preferably have to use high-quality products, equipped with superabsorbent polymers and water vapor-permeable back sheets, to minimize the risk of skin complications.
Singh, Vaneet; Rawlinson, Jeremy; Hallab, Nadim
2018-01-11
Options to treat early-onset scoliosis include guided-growth systems with sliding action between rods and pedicle screws. The wear was previously measured in an in vitro test, and in this in vivo rabbit model, we evaluated the local and systemic biological response to the stainless steel debris. Compared to the previous study, a relatively higher volume of representative wear particles with a median particle size of 0.84 μm were generated. Bolus dosages were injected into the epidural space at L4-L5 for a minimum of 36 rabbits across three treatment groups (negative control, 1.5 mg, and 4.0 mg) and two timepoints (12 and 24 weeks). Gross pathology evaluated distant organs and the injection site with a dorsal laminectomy to examine the epidural space and dosing site. Peri-implanted particle tissues were stained for immunohistochemical and quantitatively analyzed for IL-6 and TNF-α cytokines. Based on ISO 10993-6:2007 scoring, particles in the high-dose group were primarily non-irritant (12 weeks) with one slightly irritant. At 24 weeks, inflammatory cell infiltration was non-existent to minimal with all groups considered non-irritant at the injection site. Material characterization confirmed that particles detected in distant organs were stainless steel or contaminants. At 12 weeks, stainless steel groups demonstrated statistically increased amounts of cytokine levels compared to control but there was a statistical decrease for both at 24 weeks. These findings indicate that stainless steel wear debris, comparable to the expected usage from a simulated growth guidance system, had no discernible untoward biological effects locally and systemically in an animal model. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Zane, Lee T; Hughes, Matilda H; Shakib, Sepehr
2016-10-01
Inflammatory skin diseases such as atopic dermatitis (AD) and psoriasis often present in sensitive and thin-skinned areas that are at higher risk for topical treatment-related skin irritation (e.g., burning, stinging). Our objective was to address the need for topical treatments that can be safely applied to these areas. We assessed the local tolerability of crisaborole topical ointment when applied to sensitive and thin-skinned areas of healthy volunteers. In this phase I, randomized, double-blind, vehicle-controlled, single-center study, 32 subjects were randomized 3:1 to twice-daily application of crisaborole topical ointment, 2 %, (n = 24) or vehicle ointment (n = 8) for 21 days to 13 anatomic skin areas, including the face/hairline, genitals, extensor, and intertriginous areas. The primary endpoint was assessment of the frequency and severity of local tolerability symptoms (burning/stinging, erythema, and pruritus) using the Local Tolerability Scale. Overall, 98.8 % of all tolerability assessments had a grade of 0 (no signs/symptoms of irritation) and 0.1 % had a grade >1 (mild); no differences were observed in the frequency of local tolerability scores between treatment groups. The total frequency of local tolerability assessments graded >0 (none) was lower across all application sites with crisaborole ointment (0.0-2.2 %) than with vehicle ointment (2.4-7.1 %). Local tolerability did not change over time, and was comparable between sensitive and nonsensitive skin areas. Crisaborole ointment application to sensitive skin areas was well tolerated in healthy volunteers, supporting its potential role as a topical treatment alternative for patients with AD or psoriasis.
von Grote, Erika C; Palaniswarmy, Kiruthi; Meckfessel, Matthew H
2016-12-01
Occupational irritant contact dermatitis (ICD) affecting the hands is a common and difficult-to-manage condition. Occupations that necessitate contact with harsh chemicals, use of alcohol-based disinfectants, and frequent hand washing elevate the risk of ICD. Management strategies that do not adequately prevent accumulated damage and repair skin, can develop into chronic dermatoses which negatively impact work productivity and quality of life. A 2-step skin-care regimen (Excipial Daily Protection Hand Cream (EP) and Excipial Rapid Repair Hand Cream (ER), Galderma Laboratories, L.P.) has been developed as a daily-use management strategy to protect and repair vulnerable hands. The protective barrier cream is formulated with aluminum chlorohydrate and designed for pre-exposure application to enhance the skin's natural protective barrier and minimize excessive moisture while wearing protective gloves. The repair cream, a lipid-rich formulation, is intended for post-exposure application to rehydrate and facilitate the skin's natural healing process. The results of 3 clinical studies highlighted in this review demonstrate how the use of a 2-step skin-care regimen offers a greater protective effect against ICD than the use of barrier cream alone, and also how the formulation of the barrier cream used in these studies helps minimize the occlusion effect caused by gloves and does not interfere with the antibacterial efficacy of an alcohol-based hand sanitizer. This 2-step skin-care regimen is effectively designed to manage and minimize the risk of ICD development in a variety of patients and provides clinicians an additional tool for helping patients manage ICD. J Drugs Dermatol. 2016;15(12):1504-1510.
Structural characterization and viscoelastic constitutive modeling of skin.
Sherman, Vincent R; Tang, Yizhe; Zhao, Shiteng; Yang, Wen; Meyers, Marc A
2017-04-15
A fascinating material, skin has a tensile response which exhibits an extended toe region of minimal stress up to nominal strains that, in some species, exceed 1, followed by significant stiffening until a roughly linear region. The large toe region has been attributed to its unique structure, consisting of a network of curved collagen fibers. Investigation of the structure of rabbit skin reveals that it consists of layers of wavy fibers, each one with a characteristic orientation. Additionally, the existence of two preferred layer orientations is suggested based on the results of small angle X-ray scattering. These observations are used to construct a viscoelastic model consisting of collagen in two orientations, which leads to an in-plane anisotropic response. The structure-based model presented incorporates the elastic straightening and stretching of fibrils, their rotation towards the tensile axis, and the viscous effects which occur in the matrix of the skin due to interfibrillar and interlamellar sliding. The model is shown to effectively capture key features which dictate the mechanical response of skin. Examination by transmission and scanning electron microscopy of rabbit dermis enabled the identification of the key elements in its structure. The organization of collagen fibrils into flat fibers was identified and incorporated into a constitutive model that reproduces the mechanical response of skin. This enhanced quantitative predictive capability can be used in the design of synthetic skin and skin-like structures. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Mahler, V; Erfurt-Berge, C; Schiemann, S; Michael, S; Egloffstein, A; Kuss, O
2010-04-01
In occupational fields with exposure to grease, oil, metal particles, coal, black lead or soot, cleansing formulations containing abrasive bodies (e.g. refined walnut shell, corn, wood, plastic or pumice) are used. These may constitute an irritant per se. As an alternative, hydrogenated castor oil (also known as castor wax) beads have been developed as dirt-binding particles. A polar surface contributes to their mechanical cleaning effects in removal of oily grime. Standardized examination of the in vivo effects upon the skin barrier of castor wax beads in comparison with abrasive bodies and pure detergent. Three cleansing preparations - (i) detergent, (ii) detergent containing castor wax beads, (iii) detergent containing walnut shell powder - were each repetitively applied in vivo (four times daily for 3 weeks), mimicking workplace conditions, in 30 healthy volunteers (15 with and 15 without an atopic skin diathesis) and compared vs. (iv) no treatment. The treatment effects upon the skin barrier were monitored by repeated measurements of functional parameters [transepidermal water loss (TEWL), redness] and surface topography. After a 3-week treatment, a significant global treatment effect (P < 0.0001) was found in the atopic group concerning TEWL as indicator for barrier function. A significantly higher TEWL and increasing erythema in the area treated with detergent containing walnut shell powder reflected its irritant effect compared with castor wax beads dispensed in the identical detergent. Cleaning properties of the two formulas were comparably superior to detergent alone. Castor wax beads constitute a novel nonirritating alternative for abrasive cleaning of recalcitrant oily skin contamination appropriate for individuals with an atopic skin diathesis in a three-step programme of occupational skin protection. As the skin barrier may additionally be influenced by the composition of dirt and use of skin protection and skin care measures under real workplace conditions, this component may now be used and examined further in different occupations.
Skin hydration and cooling effect produced by the Voltaren® vehicle gel.
Hug, Agnes M; Schmidts, Thomas; Kuhlmann, Jens; Segger, Dörte; Fotopoulos, Grigorios; Heinzerling, Johanna
2012-05-01
Voltaren vehicle gel is the carrier substance of the topical Voltaren products. This vehicle gel is especially formulated to be easily applied on the skin, while providing some sensory benefits. The present study aims to substantiate the widely perceived hydrating and cooling effect of Voltaren vehicle gel. Volar forearm skin hydration and transepidermal water loss (TEWL) were measured and user satisfaction was evaluated by questionnaires, after application in 31 healthy, female volunteers. The cooling effect was investigated for 40 min with thermal imaging on 12 forearm sites of six healthy subjects. Voltaren vehicle gel application increased skin hydration by 13.1% (P = 0.0002) when compared with the untreated site, 8 h after the final treatment after 2 weeks. TEWL decreased on both treated (0.37 g/m(2) /h) and untreated (0.74 g/m(2) /h) forearm sites after 2 weeks (8 h after last treatment), demonstrating a relative increase of 6.5% in water loss. Voltaren vehicle gel application resulted in a rapid reduction of skin surface temperature by 5.1°C after only 3 min with an average maximum reduction of 5.8°C after 10 min. The cooling effect was experienced by 94% subjects, while 74% felt that their skin became softer. No adverse events, including skin irritation, were reported during the study and by the 37 participants. This study showed a statistically significant increase in skin hydration as well as a rapid cooling effect lasting approximately 30 min, after application of Voltaren vehicle gel. The small relative increase in water loss may be attributed to an additional skin surface water loss secondary to the increased water content brought into the skin by the Voltaren vehicle gel. The use did not induce any skin irritation and was found acceptable to use by the majority of participants. © 2011 John Wiley & Sons A/S.
Male skin and ingredients relevant to male skin care.
Draelos, Z D
2012-03-01
Male skin care needs are heavily influenced by the need to remove facial hair on a regular basis. Facial skin issues associated with poor hair removal approaches are common and include razor burn and irritation. This paper evaluates current research on shaving technology and how careful ingredient selection can contribute to male skin health. The importance of maintaining hair softness during the shave and restoring facial hydration post-shave is discussed. Data are presented on how post-shave moisturizers containing glycerine and emollients can create an environment for improved barrier function which can be further improved by incorporating specific ingredients such as niacinamide. © 2012 The Author. BJD © 2012 British Association of Dermatologists.
Schaffler, Klaus; Nicolas, Laurent B; Borta, Andreas; Brand, Tobias; Reitmeir, Peter; Roebling, Robert; Scholpp, Joachim
2017-07-01
The aim of the present study was to assess the predictivity of laser-(radiant-heat)-evoked potentials (LEPs) from the vertex electroencephalogram, using an algesimetric procedure, testing the anti-nociceptive/anti-hyperalgesic effects of single oral doses of four marketed analgesics (of different compound classes) vs. placebo, in healthy volunteers with three skin types. This was a randomized, placebo-controlled, single-blind, five-way-crossover trial. Twenty-five healthy male/female Caucasians were included (receiving celecoxib 200 mg, pregabalin 150 mg, duloxetine 60 mg, lacosamide 100 mg or placebo) in a Williams design, with CO 2 laser-induced painful stimuli to normal, ultraviolet (UV) B-inflamed and capsaicin-irritated skin. LEPs and visual analogue scale ratings were taken at baseline and hourly for 6 h postdose from all three skin types. In normal skin, the averaged postdose LEP peak-to-peak-(PtP)-amplitudes were reduced by pregabalin (-2.68 μV; 95% confidence interval (CI) -4.16, 1.19) and duloxetine (-1.73 μV; 95% CI -3.21, -0.26) but not by lacosamide and celecoxib vs. placebo. On UVB-irradiated skin, reflecting inflammatory pain, celecoxib induced a pronounced reduction in LEP PtP amplitudes vs. placebo (-6.2 μV; 95% CI -7.88, -4.51), with a smaller reduction by duloxetine (-4.54 μV; 95% CI -6.21, -2.87) and pregabalin (-3.72 μV; 95% CI -5.40, -2.04), whereas lacosamide was inactive. LEP PtP amplitudes on capsaicin-irritated skin, reflecting peripheral/spinal sensitization, as in neuropathic pain, were reduced by pregabalin (-3.78 μV; 95% CI -5.31, -2.25) and duloxetine (-2.32 μV; 95% CI -3.82, -0.82) but not by celecoxib or lacosamide vs. placebo, which was in agreement with known clinical profiles. Overall, PtP amplitude reductions were in agreement with subjective ratings. LEP algesimetry is sensitive to analgesics with different modes of action and may enable the effects of novel analgesics to be assessed during early clinical development. © 2017 The British Pharmacological Society.
Michalatou, Michaila; Androutsou, Maria Eleni; Antonopoulos, Markos; Vlahakos, Demetrios V; Agelis, George; Zulli, Anthony; Qaradakhi, Tawar; Mikkelsen, Kathleen; Apostolopoulos, Vasso; Matsoukas, John
2018-04-19
The Renin Angiotensin System (RAS) is pharmacologically targeted to reduce blood pressure, and patient compliance to oral medications is a clinical issue. The mechanisms of action of angiotensin receptor blockers (ARBs) in reducing blood pressure are not well understood, and is purported to be via a reduction of angiotensin II signaling. We aimed to develop a transdermal delivery method for ARBs (losartan potassium and valsartan) and to determine if ARBs reveal a vasodilatory effect of the novel RAS peptide, alamandine. In addition we determined the anti-hypertensive effects of the transdermal delivery patch. In vitro and in vivo experiments were performed to develop an appropriate therapeutic system, promising an alternative and more effective therapy in the treatment of hypertension. A variety of penetration enhancers were selected such as isopropyl myristate, propylene glycol, transcutol and dimenthyl sulfoxide to obtain a constant release of drugs through human skin. Small resistance vessels (kidney interlobar arteries) were mounted in organ baths and incubated with an ARB. Vasodilatory curves to alamandine were constructed Results: The in vivo studies demonstrates that systemic absorption of valsartan and losartan potassium using the appropriate formulations provides a steady state release and anti-hypertensive effect even after 24 hours of transdermal administration. No apparent skin irritations (erythema, edema) were observed with the tested formulations. We also show that blocking the AT1 receptor of rabbit interlobar arteries in vitro reveals a vasodilatory effect of alamandine. This study reveals potential mechanism of AT1 receptor blockade via alamandine, and is an important contribution in developing a favorable, convenient and painless antihypertensive therapy of prolonged duration through transdermal delivery of AT1 blockers. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuznetsov, Yu L; Kalchenko, V V; Astaf'eva, N G
2014-08-31
The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)
Effective and lesion-free cutaneous influenza vaccination
Wang, Ji; Li, Bo; Wu, Mei X.
2015-01-01
The current study details efficient lesion-free cutaneous vaccination via vaccine delivery into an array of micropores in the skin, instead of bolus injection at a single site. Such delivery effectively segregated vaccine-induced inflammation, resulting in rapid resolution of the inflammation, provided that distances between any two micropores were sufficient. When the inoculation site was treated by FDA-approved nonablative fractional laser (NAFL) before insertion of a PR8 model influenza vaccine-packaged, biodegradable microneedle array (MNs), mice displayed vigorous antigen-uptake, eliciting strong Th1-biased immunity. These animals were completely protected from homologous viral challenges, and fully or partially protected from heterologous H1N1 and H3N2 viral challenges, whereas mice receiving MNs alone suffered from severe illnesses or died of similar viral challenges. NAFL-mediated adjuvanicity was ascribed primarily to dsDNA and other “danger” signals released from laser-damaged skin cells. Thus, mice deficient in dsDNA-sensing pathway, but not Toll like receptor (TLR) or inflammasome pathways, showed poor responses to NAFL. Importantly, with this novel approach both mice and swine exhibited strong protective immunity without incurring any appreciable skin irritation, in sharp contrast to the overt skin irritation caused by intradermal injections. The effective lesion-free cutaneous vaccination merits further clinical studies. PMID:25848020
Copoví, A; Díez-Sales, O; Herráez-Domínguez, J V; Herráez-Domínguez, M
2006-05-11
The percutaneous penetration-enhancing effects of glycolic acid, lactic acid and sodium lauryl sulphate through the human epidermis was investigated using 5-fluorouracil as a hydrophilic model permeant and three compounds belonging to the phenylalcohols: 2-phenyl-ethanol, 4-phenyl-butanol and 5-phenyl-pentanol. The lipophilicity values of the compounds ranged from log Poct -0.95 to 2.89. The effect of the enhancer concentration was also studied. Skin pretreatment with aqueous solutions of the three enhancers did not increase the permeability coefficient of the most lipophilic compound (log Poct = 2.89). For the other compounds assayed, the increase in the permeability coefficients depended on the concentration used in skin pretreatment, and on the lipophilicity of the compounds tested-and was always greater for the most hydrophilic compound (5-fluorouracil), for which lactic acid exerted a greater enhancer effect than glycolic acid or sodium lauryl sulphate. Primary irritation testing of the three enhancers was also carried out at the two concentrations used in skin pretreatment for diffusional experiments (1% and 5%, w/w). The least irritant capacity corresponded to lactic acid; consequently, this alpha-hydroxyacid could be proposed as a percutaneous penetration enhancer for hydrophilic molecules that are of interest for transdermal administration.
Health survey of 167 pet rabbits (Oryctolagus cuniculus) in Finland.
Mäkitaipale, J; Harcourt-Brown, F M; Laitinen-Vapaavuori, O
2015-10-24
Only a limited amount of information is available about health status of pet rabbits. The aim of this study was to obtain data about the health status of pet rabbits considered healthy by the owners in Finland. Physical examination and lateral abdominal and lateral skull radiography were performed on 167 pet rabbits of which 118 (70.7 per cent) had abnormal findings in at least one examination. The most common findings were acquired dental disease (n=67, 40.1 per cent), vertebral column deformities and degenerative lesions (n=52, 31.1 per cent), skin disorders (n=28, 16.8 per cent) and eye disorders (n=12, 7.2 per cent). Vertebral column angulating deformities were significantly more common in dwarf lop rabbits (P≤0.001). The prevalence of health disorders was significantly higher in rabbits over three years of age of which 51 (82.3 per cent) had findings in at least one examination (P<0.05). Rabbits as prey animals hide their illness, which cause difficulties to owners to recognise health problems. Because of the high prevalence of clinical and radiological findings in apparently healthy pet rabbits, regular physical examinations are advised, especially for animals over three years old. British Veterinary Association.
30 CFR 50.20-6 - Criteria-MSHA Form 7000-1, Section C.
Code of Federal Regulations, 2010 CFR
2010-07-01
... as the first day of illness. (i) Code 21—Occupational Skin Diseases or Disorders. Examples: Contact dermatitis, eczema, or rash caused by primary irritants and sensitizers or poisonous plants; oil acne; chrome...
Vulvovaginitis: causes and management.
Pierce, A M; Hart, C A
1992-01-01
Over a period of 33 months in a paediatric accident and emergency department, the clinical pattern and possible causes of vulvovaginitis were studied prospectively in 200 girls presenting with genital discharge, irritation, pain, or redness. The major causes were poor hygiene and threadworms. The suspicion of sexual abuse arose in a few girls but no organisms of sexually transmitted disease were found. Urinary symptoms were common but only 20 patients had a significant bacteriuria and 40 had sterile pyuria. Specific skin problems occurred in 28 cases. Simple measures to improve hygiene and treatment of threadworms gave effective relief. Genital irritation caused urinary symptoms with no clinical evidence of infection, and it is advised that antibiotic treatment should await urine culture. Specific skin problems require help from a dermatologist. The possibility of sexual abuse must be considered especially if the vulvovaginitis is persistent or recurrent after adequate treatment. PMID:1580682
Biomaterials as novel penetration enhancers for transdermal and dermal drug delivery systems.
Chen, Yang; Wang, Manli; Fang, Liang
2013-01-01
The highly organized structure of the stratum corneum provides an effective barrier to the drug delivery into or across the skin. To overcome this barrier function, penetration enhancers are always used in the transdermal and dermal drug delivery systems. However, the conventional chemical enhancers are often limited by their inability to delivery large and hydrophilic molecules, and few to date have been routinely incorporated into the transdermal formulations due to their incompatibility and local irritation issues. Therefore, there has been a search for the compounds that exhibit broad enhancing activity for more drugs without producing much irritation. More recently, the use of biomaterials has emerged as a novel method to increase the skin permeability. In this paper, we present an overview of the investigations on the feasibility and application of biomaterials as penetration enhancers for transdermal or dermal drug delivery systems.