Methodologies in the modeling of combined chemo-radiation treatments
NASA Astrophysics Data System (ADS)
Grassberger, C.; Paganetti, H.
2016-11-01
The variety of treatment options for cancer patients has increased significantly in recent years. Not only do we combine radiation with surgery and chemotherapy, new therapeutic approaches such as immunotherapy and targeted therapies are starting to play a bigger role. Physics has made significant contributions to radiation therapy treatment planning and delivery. In particular, treatment plan optimization using inverse planning techniques has improved dose conformity considerably. Furthermore, medical physics is often the driving force behind tumor control and normal tissue complication modeling. While treatment optimization and outcome modeling does focus mainly on the effects of radiation, treatment modalities such as chemotherapy are treated independently or are even neglected entirely. This review summarizes the published efforts to model combined modality treatments combining radiation and chemotherapy. These models will play an increasing role in optimizing cancer therapy not only from a radiation and drug dosage standpoint, but also in terms of spatial and temporal optimization of treatment schedules.
Falcon: automated optimization method for arbitrary assessment criteria
Yang, Tser-Yuan; Moses, Edward I.; Hartmann-Siantar, Christine
2001-01-01
FALCON is a method for automatic multivariable optimization for arbitrary assessment criteria that can be applied to numerous fields where outcome simulation is combined with optimization and assessment criteria. A specific implementation of FALCON is for automatic radiation therapy treatment planning. In this application, FALCON implements dose calculations into the planning process and optimizes available beam delivery modifier parameters to determine the treatment plan that best meets clinical decision-making criteria. FALCON is described in the context of the optimization of external-beam radiation therapy and intensity modulated radiation therapy (IMRT), but the concepts could also be applied to internal (brachytherapy) radiotherapy. The radiation beams could consist of photons or any charged or uncharged particles. The concept of optimizing source distributions can be applied to complex radiography (e.g. flash x-ray or proton) to improve the imaging capabilities of facilities proposed for science-based stockpile stewardship.
Optimizing Timing of Immunotherapy Improves Control of Tumors by Hypofractionated Radiation Therapy
Baird, Jason R.; Savage, Talicia; Cottam, Benjamin; Friedman, David; Bambina, Shelly; Messenheimer, David J.; Fox, Bernard; Newell, Pippa; Bahjat, Keith S.; Gough, Michael J.; Crittenden, Marka R.
2016-01-01
The anecdotal reports of promising results seen with immunotherapy and radiation in advanced malignancies have prompted several trials combining immunotherapy and radiation. However, the ideal timing of immunotherapy with radiation has not been clarified. Tumor bearing mice were treated with 20Gy radiation delivered only to the tumor combined with either anti-CTLA4 antibody or anti-OX40 agonist antibody. Immunotherapy was delivered at a single timepoint around radiation. Surprisingly, the optimal timing of these therapies varied. Anti-CTLA4 was most effective when given prior to radiation therapy, in part due to regulatory T cell depletion. Administration of anti-OX40 agonist antibody was optimal when delivered one day following radiation during the post-radiation window of increased antigen presentation. Combination treatment of anti-CTLA4, radiation, and anti-OX40 using the ideal timing in a transplanted spontaneous mammary tumor model demonstrated tumor cures. These data demonstrate that the combination of immunotherapy and radiation results in improved therapeutic efficacy, and that the ideal timing of administration with radiation is dependent on the mechanism of action of the immunotherapy utilized. PMID:27281029
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beltran, C; Kamal, H
Purpose: To provide a multicriteria optimization algorithm for intensity modulated radiation therapy using pencil proton beam scanning. Methods: Intensity modulated radiation therapy using pencil proton beam scanning requires efficient optimization algorithms to overcome the uncertainties in the Bragg peaks locations. This work is focused on optimization algorithms that are based on Monte Carlo simulation of the treatment planning and use the weights and the dose volume histogram (DVH) control points to steer toward desired plans. The proton beam treatment planning process based on single objective optimization (representing a weighted sum of multiple objectives) usually leads to time-consuming iterations involving treatmentmore » planning team members. We proved a time efficient multicriteria optimization algorithm that is developed to run on NVIDIA GPU (Graphical Processing Units) cluster. The multicriteria optimization algorithm running time benefits from up-sampling of the CT voxel size of the calculations without loss of fidelity. Results: We will present preliminary results of Multicriteria optimization for intensity modulated proton therapy based on DVH control points. The results will show optimization results of a phantom case and a brain tumor case. Conclusion: The multicriteria optimization of the intensity modulated radiation therapy using pencil proton beam scanning provides a novel tool for treatment planning. Work support by a grant from Varian Inc.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dolly, S; Mutic, S; Anastasio, M
Purpose: Traditionally, image quality in radiation therapy is assessed subjectively or by utilizing physically-based metrics. Some model observers exist for task-based medical image quality assessment, but almost exclusively for diagnostic imaging tasks. As opposed to disease diagnosis, the task for image observers in radiation therapy is to utilize the available images to design and deliver a radiation dose which maximizes patient disease control while minimizing normal tissue damage. The purpose of this study was to design and implement a new computer simulation model observer to enable task-based image quality assessment in radiation therapy. Methods: A modular computer simulation framework wasmore » developed to resemble the radiotherapy observer by simulating an end-to-end radiation therapy treatment. Given images and the ground-truth organ boundaries from a numerical phantom as inputs, the framework simulates an external beam radiation therapy treatment and quantifies patient treatment outcomes using the previously defined therapeutic operating characteristic (TOC) curve. As a preliminary demonstration, TOC curves were calculated for various CT acquisition and reconstruction parameters, with the goal of assessing and optimizing simulation CT image quality for radiation therapy. Sources of randomness and bias within the system were analyzed. Results: The relationship between CT imaging dose and patient treatment outcome was objectively quantified in terms of a singular value, the area under the TOC (AUTOC) curve. The AUTOC decreases more rapidly for low-dose imaging protocols. AUTOC variation introduced by the dose optimization algorithm was approximately 0.02%, at the 95% confidence interval. Conclusion: A model observer has been developed and implemented to assess image quality based on radiation therapy treatment efficacy. It enables objective determination of appropriate imaging parameter values (e.g. imaging dose). Framework flexibility allows for incorporation of additional modules to include any aspect of the treatment process, and therefore has great potential for both assessment and optimization within radiation therapy.« less
On-line Adaptive Radiation Treatment of Prostate Cancer
2009-01-01
12]. For intensity modulated radiation therapy (IMRT) plans , the beamlet weight can be re-optimized on a daily basis to mini- mize the dose to the OAR...Thongphiew D, Wang Z, Mathayomchan B, Chankong V, Yoo S, et al. On-line re-optimization of prostate IMRT plans for adaptive radiation therapy . Phys Med Biol...time. The treatment planning method for VMAT however is not mature. We are developing a robust VMAT treatment planning method which incorporates
De Bari, Berardino; Jumeau, Raphael; Deantonio, Letizia; Adib, Salim; Godin, Sarah; Zeverino, Michele; Moeckli, Raphael; Bourhis, Jean; Prior, John O; Ozsahin, Mahmut
2016-10-13
We report the first known instance of the clinical use of 99mTc-mebrofenin hepatobiliary scintigraphy (HBS) for the optimization of radiotherapy treatment planning and for the follow-up of acute toxicity in a patient undergoing stereotactic body radiation therapy for hepatocellular carcinoma. In our experience, HBS allowed the identification and the sparing of more functioning liver areas, thus potentially reducing the risk of radiation-induced liver toxicity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ning Shoucheng; Knox, Susan J.
2006-06-01
Purpose: The primary objective was to optimize the combined treatment regimen using arsenic trioxide (ATO) and fractionated radiotherapy for the treatment of malignant glioma. Methods and Materials: Nude mice with human glioma xenograft tumors were treated with fractionated local tumor radiation of 250 cGy/fraction/day and 5 mg/kg ATO for 5-10 days. Results: Time course experiments demonstrated that maximal tumor growth delay occurred when ATO was administered between 0 and 4 h after radiation. The combination treatment of ATO and radiation synergistically inhibited tumor growth and produced a tumor growth delay time of 13.2 days, compared with 1.4 days and 6.5more » days for ATO and radiation alone (p < 0.01), respectively. The use of concurrent therapy of radiation and ATO initially, followed by ATO as maintenance therapy, was superior to the use of preloading with ATO before combined therapy and produced a tumor growth delay time of 22.7 days as compared with 11.7 days for the ATO preloading regimen (p < 0.01). The maintenance dose of ATO after concurrent therapy was effective and important for continued inhibition of tumor growth. Conclusions: The combined use of fractionated radiation and ATO is effective for the treatment of glioma xenograft tumors. ATO was most effective when administered 0-4 h after radiation without pretreatment with ATO. These results have important implications for the optimization of treatment regimen using ATO and fractionated radiotherapy for the treatment of brain tumors.« less
NASA Astrophysics Data System (ADS)
Budiyono, T.; Budi, W. S.; Hidayanto, E.
2016-03-01
Radiation therapy for brain malignancy is done by giving a dose of radiation to a whole volume of the brain (WBRT) followed by a booster at the primary tumor with more advanced techniques. Two external radiation fields given from the right and left side. Because the shape of the head, there will be an unavoidable hotspot radiation dose of greater than 107%. This study aims to optimize planning of radiation therapy using field in field multi-leaf collimator technique. A study of 15 WBRT samples with CT slices is done by adding some segments of radiation in each field of radiation and delivering appropriate dose weighting using a TPS precise plan Elekta R 2.15. Results showed that this optimization a more homogeneous radiation on CTV target volume, lower dose in healthy tissue, and reduced hotspots in CTV target volume. Comparison results of field in field multi segmented MLC technique with standard conventional technique for WBRT are: higher average minimum dose (77.25% ± 0:47%) vs (60% ± 3:35%); lower average maximum dose (110.27% ± 0.26%) vs (114.53% ± 1.56%); lower hotspot volume (5.71% vs 27.43%); and lower dose on eye lenses (right eye: 9.52% vs 18.20%); (left eye: 8.60% vs 16.53%).
NASA Astrophysics Data System (ADS)
Dolly, Steven R.; Anastasio, Mark A.; Yu, Lifeng; Li, Hua
2017-03-01
In current radiation therapy practice, image quality is still assessed subjectively or by utilizing physically-based metrics. Recently, a methodology for objective task-based image quality (IQ) assessment in radiation therapy was proposed by Barrett et al.1 In this work, we present a comprehensive implementation and evaluation of this new IQ assessment methodology. A modular simulation framework was designed to perform an automated, computer-simulated end-to-end radiation therapy treatment. A fully simulated framework was created that utilizes new learning-based stochastic object models (SOM) to obtain known organ boundaries, generates a set of images directly from the numerical phantoms created with the SOM, and automates the image segmentation and treatment planning steps of a radiation therapy work ow. By use of this computational framework, therapeutic operating characteristic (TOC) curves can be computed and the area under the TOC curve (AUTOC) can be employed as a figure-of-merit to guide optimization of different components of the treatment planning process. The developed computational framework is employed to optimize X-ray CT pre-treatment imaging. We demonstrate that use of the radiation therapy-based-based IQ measures lead to different imaging parameters than obtained by use of physical-based measures.
Million, Lynn; Donaldson, Sarah S.
2012-01-01
It remains unclear which children and adolescents with resected nonrhabdomyosarcoma soft tissue sarcoma (NRSTS) benefit from radiation therapy, as well as the optimal dose, volume, and timing of radiotherapy when used with primary surgical resection. This paper reviews the sparse literature from clinical trials and retrospective studies of resected pediatric NRSTS to discern local recurrence rates in relationship to the use of radiation therapy. PMID:22523704
NASA Astrophysics Data System (ADS)
McGeachy, Philip David
Over 50% of cancer patients require radiation therapy (RT). RT is an optimization problem requiring maximization of the radiation damage to the tumor while minimizing the harm to the healthy tissues. This dissertation focuses on two main RT optimization problems: 1) brachytherapy and 2) intensity modulated radiation therapy (IMRT). The brachytherapy research involved solving a non-convex optimization problem by creating an open-source genetic algorithm optimizer to determine the optimal radioactive seed distribution for a given set of patient volumes and constraints, both dosimetric- and implant-based. The optimizer was tested for a set of 45 prostate brachytherapy patients. While all solutions met the clinical standards, they also benchmarked favorably with those generated by a standard commercial solver. Compared to its compatriot, the salient features of the generated solutions were: slightly reduced prostate coverage, lower dose to the urethra and rectum, and a smaller number of needles required for an implant. Historically, IMRT requires modulation of fluence while keeping the photon beam energy fixed. The IMRT-related investigation in this thesis aimed at broadening the solution space by varying photon energy. The problem therefore involved simultaneous optimization of photon beamlet energy and fluence, denoted by XMRT. Formulating the problem as convex, linear programming was applied to obtain solutions for optimal energy-dependent fluences, while achieving all clinical objectives and constraints imposed. Dosimetric advantages of XMRT over single-energy IMRT in the improved sparing of organs at risk (OARs) was demonstrated in simplified phantom studies. The XMRT algorithm was improved to include clinical dose-volume constraints and clinical studies for prostate and head and neck cancer patients were investigated. Compared to IMRT, XMRT provided improved dosimetric benefit in the prostate case, particularly within intermediate- to low-dose regions (≤ 40 Gy) for OARs. For head and neck cases, XMRT solutions showed no significant disadvantage or advantage over IMRT. The deliverability concerns for the fluence maps generated from XMRT were addressed by incorporating smoothing constraints during the optimization and through successful generation of treatment machine files. Further research is needed to explore the full potential of the XMRT approach to RT.
Strategies for optimizing the response of cancer and normal tissues to radiation
Moding, Everett J.; Kastan, Michael B.; Kirsch, David G.
2014-01-01
Approximately 50% of all patients with cancer receive radiation therapy at some point during the course of their treatment, and the majority of these patients are treated with curative intent. Despite recent advances in the planning of radiation treatment and the delivery of image-guided radiation therapy, acute toxicity and potential long-term side effects often limit the ability to deliver a sufficient dose of radiation to control tumours locally. In the past two decades, a better understanding of the hallmarks of cancer and the discovery of specific signalling pathways by which cells respond to radiation have provided new opportunities to design molecularly targeted therapies to increase the therapeutic window of radiation therapy. Here, we review efforts to develop approaches that could improve outcomes with radiation therapy by increasing the probability of tumour cure or by decreasing normal tissue toxicity. PMID:23812271
Adjuvant radiation therapy for pancreatic cancer: a review of the old and the new.
Boyle, John; Czito, Brian; Willett, Christopher; Palta, Manisha
2015-08-01
Surgery represents the only potential curative treatment option for patients diagnosed with pancreatic adenocarcinoma. Despite aggressive surgical management for patients deemed to be resectable, rates of local recurrence and/or distant metastases remain high, resulting in poor long-term outcomes. In an effort to reduce recurrence rates and improve survival for patients having undergone resection, adjuvant therapies (ATs) including chemotherapy and chemoradiation therapy (CRT) have been explored. While adjuvant chemotherapy has been shown to consistently improve outcomes, the data regarding adjuvant radiation therapy (RT) is mixed. Although the ability of radiation to improve local control has been demonstrated, it has not always led to improved survival outcomes for patients. Early trials are flawed in their utilization of sub-optimal radiation techniques, limiting their generalizability. Recent and ongoing trials incorporate more optimized RT approaches and seek to clarify its role in treatment strategies. At the same time novel radiation techniques such as intensity modulated RT (IMRT) and stereotactic body RT (SBRT) are under active investigation. It is hoped that these efforts will lead to improved disease-related outcomes while reducing toxicity rates.
Adjuvant radiation therapy for pancreatic cancer: a review of the old and the new
Boyle, John; Czito, Brian; Willett, Christopher
2015-01-01
Surgery represents the only potential curative treatment option for patients diagnosed with pancreatic adenocarcinoma. Despite aggressive surgical management for patients deemed to be resectable, rates of local recurrence and/or distant metastases remain high, resulting in poor long-term outcomes. In an effort to reduce recurrence rates and improve survival for patients having undergone resection, adjuvant therapies (ATs) including chemotherapy and chemoradiation therapy (CRT) have been explored. While adjuvant chemotherapy has been shown to consistently improve outcomes, the data regarding adjuvant radiation therapy (RT) is mixed. Although the ability of radiation to improve local control has been demonstrated, it has not always led to improved survival outcomes for patients. Early trials are flawed in their utilization of sub-optimal radiation techniques, limiting their generalizability. Recent and ongoing trials incorporate more optimized RT approaches and seek to clarify its role in treatment strategies. At the same time novel radiation techniques such as intensity modulated RT (IMRT) and stereotactic body RT (SBRT) are under active investigation. It is hoped that these efforts will lead to improved disease-related outcomes while reducing toxicity rates. PMID:26261730
[The laser therapy of rheumatoid arthritis].
Soroka, N F
1989-01-01
About 300 patients with rheumatoid arthritis (RA) underwent multimodality treatment including laser radiation of varying wavelengths. Use was made of helium-neon, infrared, argon and helium-cadmium lasers. A new method of combined laser therapy by radiation of helium-cadmium and helium-neon lasers is described. A scheme of optimal parameters and types of laser radiation recommended for the treatment of different clinical varieties of RA is provided.
Poster — Thur Eve — 61: A new framework for MPERT plan optimization using MC-DAO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, M; Lloyd, S AM; Townson, R
2014-08-15
This work combines the inverse planning technique known as Direct Aperture Optimization (DAO) with Intensity Modulated Radiation Therapy (IMRT) and combined electron and photon therapy plans. In particular, determining conditions under which Modulated Photon/Electron Radiation Therapy (MPERT) produces better dose conformality and sparing of organs at risk than traditional IMRT plans is central to the project. Presented here are the materials and methods used to generate and manipulate the DAO procedure. Included is the introduction of a powerful Java-based toolkit, the Aperture-based Monte Carlo (MC) MPERT Optimizer (AMMO), that serves as a framework for optimization and provides streamlined access tomore » underlying particle transport packages. Comparison of the toolkit's dose calculations to those produced by the Eclipse TPS and the demonstration of a preliminary optimization are presented as first benchmarks. Excellent agreement is illustrated between the Eclipse TPS and AMMO for a 6MV photon field. The results of a simple optimization shows the functioning of the optimization framework, while significant research remains to characterize appropriate constraints.« less
NASA Astrophysics Data System (ADS)
Rocha, Humberto; Dias, Joana M.; Ferreira, Brígida C.; Lopes, Maria C.
2013-05-01
Generally, the inverse planning of radiation therapy consists mainly of the fluence optimization. The beam angle optimization (BAO) in intensity-modulated radiation therapy (IMRT) consists of selecting appropriate radiation incidence directions and may influence the quality of the IMRT plans, both to enhance better organ sparing and to improve tumor coverage. However, in clinical practice, most of the time, beam directions continue to be manually selected by the treatment planner without objective and rigorous criteria. The goal of this paper is to introduce a novel approach that uses beam’s-eye-view dose ray tracing metrics within a pattern search method framework in the optimization of the highly non-convex BAO problem. Pattern search methods are derivative-free optimization methods that require a few function evaluations to progress and converge and have the ability to better avoid local entrapment. The pattern search method framework is composed of a search step and a poll step at each iteration. The poll step performs a local search in a mesh neighborhood and ensures the convergence to a local minimizer or stationary point. The search step provides the flexibility for a global search since it allows searches away from the neighborhood of the current iterate. Beam’s-eye-view dose metrics assign a score to each radiation beam direction and can be used within the pattern search framework furnishing a priori knowledge of the problem so that directions with larger dosimetric scores are tested first. A set of clinical cases of head-and-neck tumors treated at the Portuguese Institute of Oncology of Coimbra is used to discuss the potential of this approach in the optimization of the BAO problem.
NASA Astrophysics Data System (ADS)
Sengbusch, Evan R.
Physical properties of proton interactions in matter give them a theoretical advantage over photons in radiation therapy for cancer treatment, but they are seldom used relative to photons. The primary barriers to wider acceptance of proton therapy are the technical feasibility, size, and price of proton therapy systems. Several aspects of the proton therapy landscape are investigated, and new techniques for treatment planning, optimization, and beam delivery are presented. The results of these investigations suggest a means by which proton therapy can be delivered more efficiently, effectively, and to a much larger proportion of eligible patients. An analysis of the existing proton therapy market was performed. Personal interviews with over 30 radiation oncology leaders were conducted with regard to the current and future use of proton therapy. In addition, global proton therapy market projections are presented. The results of these investigations serve as motivation and guidance for the subsequent development of treatment system designs and treatment planning, optimization, and beam delivery methods. A major factor impacting the size and cost of proton treatment systems is the maximum energy of the accelerator. Historically, 250 MeV has been the accepted value, but there is minimal quantitative evidence in the literature that supports this standard. A retrospective study of 100 patients is presented that quantifies the maximum proton kinetic energy requirements for cancer treatment, and the impact of those results with regard to treatment system size, cost, and neutron production is discussed. This study is subsequently expanded to include 100 cranial stereotactic radiosurgery (SRS) patients, and the results are discussed in the context of a proposed dedicated proton SRS treatment system. Finally, novel proton therapy optimization and delivery techniques are presented. Algorithms are developed that optimize treatment plans over beam angle, spot size, spot spacing, beamlet weight, the number of delivered beamlets, and the number of delivery angles. These methods are evaluated via treatment planning studies including left-sided whole breast irradiation, lung stereotactic body radiotherapy, nasopharyngeal carcinoma, and whole brain radiotherapy with hippocampal avoidance. Improvements in efficiency and efficacy relative to traditional proton therapy and intensity modulated photon radiation therapy are discussed.
[Basic principles and results of brachytherapy in gynecological oncology].
Kanaev, S V; Turkevich, V G; Baranov, S B; Savel'eva, V V
2014-01-01
The fundamental basics of contact radiation therapy (brachytherapy) for gynecological cancer are presented. During brachytherapy the principles of conformal radiotherapy should be implemented, the aim of which is to sum the maximum possible dose of radiation to the tumor and decrease the dose load in adjacent organs and tissues, which allows reducing the frequency of radiation damage at treatment of primary tumors. It is really feasible only on modern technological level, thanks to precision topometry preparation, optimal computer dosimetrical and radiobiological planning of each session and radiotherapy in general. Successful local and long-term results of the contact radiation therapy for cancer of cervix and endometrium are due to optimal anatomical and topometrical ratio of the tumor localization, radioactive sources, and also physical and radiobiological laws of distribution and effects of ionizing radiation, the dose load accounting rules.
Smith, Wade P; Kim, Minsun; Holdsworth, Clay; Liao, Jay; Phillips, Mark H
2016-03-11
To build a new treatment planning approach that extends beyond radiation transport and IMRT optimization by modeling the radiation therapy process and prognostic indicators for more outcome-focused decision making. An in-house treatment planning system was modified to include multiobjective inverse planning, a probabilistic outcome model, and a multi-attribute decision aid. A genetic algorithm generated a set of plans embodying trade-offs between the separate objectives. An influence diagram network modeled the radiation therapy process of prostate cancer using expert opinion, results of clinical trials, and published research. A Markov model calculated a quality adjusted life expectancy (QALE), which was the endpoint for ranking plans. The Multiobjective Evolutionary Algorithm (MOEA) was designed to produce an approximation of the Pareto Front representing optimal tradeoffs for IMRT plans. Prognostic information from the dosimetrics of the plans, and from patient-specific clinical variables were combined by the influence diagram. QALEs were calculated for each plan for each set of patient characteristics. Sensitivity analyses were conducted to explore changes in outcomes for variations in patient characteristics and dosimetric variables. The model calculated life expectancies that were in agreement with an independent clinical study. The radiation therapy model proposed has integrated a number of different physical, biological and clinical models into a more comprehensive model. It illustrates a number of the critical aspects of treatment planning that can be improved and represents a more detailed description of the therapy process. A Markov model was implemented to provide a stronger connection between dosimetric variables and clinical outcomes and could provide a practical, quantitative method for making difficult clinical decisions.
Zhu, Z; Zhang, J; Liu, Y; Chen, M; Guo, P; Li, K
2014-01-01
Background: Many radiation regimens for treating prostate cancer have been used over the years, but which regimen is optimal for localised or locally advanced prostate cancer lacks consensus. We performed a network meta-analysis to identify the optimal radiation regimen. Methods: We systematically reviewed data from 27 randomised controlled trials and could group seven radiation regimens as follows: low- and high-dose radiation therapy (LDRT and HDRT), LDRT+ short- or long-term androgen deprivation therapy (LDRT+SADT and LDRT+LADT), HDRT+SADT, hypofractionated radiotherapy (HFRT), and HFRT+SADT. The main outcomes were overall mortality (OM), prostate-specific antigen (PSA) failure, cancer-specific mortality, and adverse events. Results: For the network meta-analysis of 27 trials, LDRT+LADT and LDRT+SADT were associated with decreased risk of OM as compared with LDRT alone as was LDRT+LADT compared with HDRT. Apart from HFRT, all other treatments were associated with decreased risk of PSA failure as compared with LDRT. HFRT+SADT was associated with decreased risk of cancer-specific mortality as compared with HFRT, LDRT+SADT, HDRT, and LDRT. Conclusions: HFRT+SADT therapy might be the most efficacious treatment but with worst toxicity for localised or locally advanced prostate cancer, and HDRT showed excellent efficacy but more adverse events. PMID:24736585
Radiation-Induced Immune Modulation in Prostate Cancer
2008-01-01
cancers. 15. SUBJECT TERMS Radiation, Dendritic Cells , Cytokines, PSA 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18...radiation is more than a cytotoxic agent. Our recent study has shown that radiation modulates the immune system by affecting dendritic cell (DC...translate radiation-induced tumor cell death into generation of tumor immunity in the hope of optimizing therapy for localized and disseminated prostate
Madu, C N; Quint, D J; Normolle, D P; Marsh, R B; Wang, E Y; Pierce, L J
2001-11-01
To delineate with computed tomography (CT) the anatomic regions containing the supraclavicular (SCV) and infraclavicular (IFV) nodal groups, to define the course of the brachial plexus, to estimate the actual radiation dose received by these regions in a series of patients treated in the traditional manner, and to compare these doses to those received with an optimized dosimetric technique. Twenty patients underwent contrast material-enhanced CT for the purpose of radiation therapy planning. CT scans were used to study the location of the SCV and IFV nodal regions by using outlining of readily identifiable anatomic structures that define the nodal groups. The brachial plexus was also outlined by using similar methods. Radiation therapy doses to the SCV and IFV were then estimated by using traditional dose calculations and optimized planning. A repeated measures analysis of covariance was used to compare the SCV and IFV depths and to compare the doses achieved with the traditional and optimized methods. Coverage by the 90% isodose surface was significantly decreased with traditional planning versus conformal planning as the depth to the SCV nodes increased (P < .001). Significantly decreased coverage by using the 90% isodose surface was demonstrated for traditional planning versus conformal planning with increasing IFV depth (P = .015). A linear correlation was found between brachial plexus depth and SCV depth up to 7 cm. Conformal optimized planning provided improved dosimetric coverage compared with standard techniques.
SU-E-T-211: Peer Review System for Ensuring Quality of Radiation Therapy Treatments.
Kapoor, R; Kapur, P; Kumar, S A; Alex, D; Ranka, S; Palta, J
2012-06-01
To demonstrate a Web-based electronic peer review system that has the potential to improve quality of care for radiation therapy patients. The system provides tools that allow radiation oncologists to seek peer review of target and critical structure delineation, treatment plans, and share clinical data with peers to optimize radiation therapy treatments. Peer review of radiation therapy treatment planning data prior to its initiation improves the quality of radiation therapy and clinical outcomes. Web-based access to radiation therapy treatment planning data and medical records mitigate existing geographical and temporal constraints. With internet access, the healthcare provider can access the data from any location and review it in an interactive and collaborative manner. Interoperability standard like DICOM-RT and IHE-RO compliant RT Systems have facilitated the design and implementation of PRS with Silverlight Web technology, .net Framework and SQL Server. Local DICOM-RT archive and cloud based services are deployed to facilitate remote peer reviews. To validate the PRS system, we tested the system for 100 patients with Philips Pinnacle v 9.0 and Varian Eclipse v 8.9 treatment planning system (TPS). We transmitted the DICOM RT data from the TPS to the cloud based services via the PRS local DICOM RT Archive. Various CT simulation based parameters such as orientation of CT, properties of RT structures etc. were compared between the TPS and PRS system. Data integrity of other parameters such as patient demographics (patient name, ID, attending physician etc.) and dose volume related parameters were also evaluated. Such rigorous testing allowed us to optimize the functionalities and clinical implementation of the PRS. We believe that the PRS will improve the quality and safety of a broad spectrum of radiation therapy patients treated in underserved areas while discouraging the overutilization of expensive radiation treatment modalities. This research and development project is supported by the James and Ester King Biomedical Research Program grant # RC1-09KW-09-26829. © 2012 American Association of Physicists in Medicine.
Palta, Jatinder R; Liu, Chihray; Li, Jonathan G
2008-01-01
The traditional prescriptive quality assurance (QA) programs that attempt to ensure the safety and reliability of traditional external beam radiation therapy are limited in their applicability to such advanced radiation therapy techniques as three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, inverse treatment planning, stereotactic radiosurgery/radiotherapy, and image-guided radiation therapy. The conventional QA paradigm, illustrated by the American Association of Physicists in Medicine Radiation Therapy Committee Task Group 40 (TG-40) report, consists of developing a consensus menu of tests and device performance specifications from a generic process model that is assumed to apply to all clinical applications of the device. The complexity, variation in practice patterns, and level of automation of high-technology radiotherapy renders this "one-size-fits-all" prescriptive QA paradigm ineffective or cost prohibitive if the high-probability error pathways of all possible clinical applications of the device are to be covered. The current approaches to developing comprehensive prescriptive QA protocols can be prohibitively time consuming and cost ineffective and may sometimes fail to adequately safeguard patients. It therefore is important to evaluate more formal error mitigation and process analysis methods of industrial engineering to more optimally focus available QA resources on process components that have a significant likelihood of compromising patient safety or treatment outcomes.
Cuneo, Kyle C.; Nyati, Mukesh K.; Ray, Dipankar; Lawrence, Theodore S.
2015-01-01
The epidermal growth factor receptor (EGFR) plays an important role in tumor progression and treatment resistance for many types of malignancies including head and neck, colorectal, and nonsmall cell lung cancer. Several EGFR targeted therapies are efficacious as single agents or in combination with chemotherapy. Given the toxicity associated with chemoradiation and poor outcomes seen in several types of cancers, combinations of EGFR targeted agents with or without chemotherapy have been tested in patients receiving radiation. To date, the only FDA approved use of an anti-EGFR therapy in combination with radiation therapy is for locally advanced head and neck cancer. Given the important role EGFR plays in lung and colorectal cancer and the benefit of EGFR inhibition combined with chemotherapy in these disease sites, it is perplexing why EGFR targeted therapies in combination with radiation or chemoradiation have not been more successful. In this review we summarize the clinical findings of EGFR targeted therapies combined with radiation and chemoradiation regimens. We then discuss the interaction between EGFR and radiation including radiation induced EGFR signaling, the effect of EGFR on DNA damage repair, and potential mechanisms of radiosensitization. Finally, we examine the potential pitfalls with scheduling EGFR targeted therapies with chemoradiation and the use of predictive biomarkers to improve patient selection. PMID:26205191
Censor, Yair; Unkelbach, Jan
2011-01-01
In this paper we look at the development of radiation therapy treatment planning from a mathematical point of view. Historically, planning for Intensity-Modulated Radiation Therapy (IMRT) has been considered as an inverse problem. We discuss first the two fundamental approaches that have been investigated to solve this inverse problem: Continuous analytic inversion techniques on one hand, and fully-discretized algebraic methods on the other hand. In the second part of the paper, we review another fundamental question which has been subject to debate from the beginning of IMRT until the present day: The rotation therapy approach versus fixed angle IMRT. This builds a bridge from historic work on IMRT planning to contemporary research in the context of Intensity-Modulated Arc Therapy (IMAT). PMID:21616694
Automatic CT simulation optimization for radiation therapy: A general strategy.
Li, Hua; Yu, Lifeng; Anastasio, Mark A; Chen, Hsin-Chen; Tan, Jun; Gay, Hiram; Michalski, Jeff M; Low, Daniel A; Mutic, Sasa
2014-03-01
In radiation therapy, x-ray computed tomography (CT) simulation protocol specifications should be driven by the treatment planning requirements in lieu of duplicating diagnostic CT screening protocols. The purpose of this study was to develop a general strategy that allows for automatically, prospectively, and objectively determining the optimal patient-specific CT simulation protocols based on radiation-therapy goals, namely, maintenance of contouring quality and integrity while minimizing patient CT simulation dose. The authors proposed a general prediction strategy that provides automatic optimal CT simulation protocol selection as a function of patient size and treatment planning task. The optimal protocol is the one that delivers the minimum dose required to provide a CT simulation scan that yields accurate contours. Accurate treatment plans depend on accurate contours in order to conform the dose to actual tumor and normal organ positions. An image quality index, defined to characterize how simulation scan quality affects contour delineation, was developed and used to benchmark the contouring accuracy and treatment plan quality within the predication strategy. A clinical workflow was developed to select the optimal CT simulation protocols incorporating patient size, target delineation, and radiation dose efficiency. An experimental study using an anthropomorphic pelvis phantom with added-bolus layers was used to demonstrate how the proposed prediction strategy could be implemented and how the optimal CT simulation protocols could be selected for prostate cancer patients based on patient size and treatment planning task. Clinical IMRT prostate treatment plans for seven CT scans with varied image quality indices were separately optimized and compared to verify the trace of target and organ dosimetry coverage. Based on the phantom study, the optimal image quality index for accurate manual prostate contouring was 4.4. The optimal tube potentials for patient sizes of 38, 43, 48, 53, and 58 cm were 120, 140, 140, 140, and 140 kVp, respectively, and the corresponding minimum CTDIvol for achieving the optimal image quality index 4.4 were 9.8, 32.2, 100.9, 241.4, and 274.1 mGy, respectively. For patients with lateral sizes of 43-58 cm, 120-kVp scan protocols yielded up to 165% greater radiation dose relative to 140-kVp protocols, and 140-kVp protocols always yielded a greater image quality index compared to the same dose-level 120-kVp protocols. The trace of target and organ dosimetry coverage and the γ passing rates of seven IMRT dose distribution pairs indicated the feasibility of the proposed image quality index for the predication strategy. A general strategy to predict the optimal CT simulation protocols in a flexible and quantitative way was developed that takes into account patient size, treatment planning task, and radiation dose. The experimental study indicated that the optimal CT simulation protocol and the corresponding radiation dose varied significantly for different patient sizes, contouring accuracy, and radiation treatment planning tasks.
NASA Astrophysics Data System (ADS)
Kim, Kyo-Tae; Heo, Ye-Ji; Han, Moo-Jae; Oh, Kyung-Min; Lee, Young-Kyu; Kim, Shin-Wook; Park, Sung-Kwang
2017-04-01
In radiation therapy, accurate radiotherapy treatment plan (RTP) reproduction is necessary to optimize the clinical results. Thus, attempts have recently been made to ensure high RTP reproducibility using image-guide radiation therapy (IGRT) technology. However, the clinical use of digital X-ray equipment requires extended quality assurance (QA) for those devices, since the IGRT device quality determines the precision of intensity-modulated radiation therapy. The study described in this paper was focused on developing a multi-energy PbO dosimeter for IGRT device QA. The Schottky-type polycrystalline PbO dosimeter with a Au/PbO/ITO structure was evaluated by comparing its response coincidence, dose linearity, measurement reproducibility, linear attenuation coefficient, and percent depth dose with those of Si diode and standard ionization chamber dosimeters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Specht, Lena, E-mail: lena.specht@regionh.dk; Yahalom, Joachim; Illidge, Tim
2014-07-15
Radiation therapy (RT) is the most effective single modality for local control of Hodgkin lymphoma (HL) and an important component of therapy for many patients. These guidelines have been developed to address the use of RT in HL in the modern era of combined modality treatment. The role of reduced volumes and doses is addressed, integrating modern imaging with 3-dimensional (3D) planning and advanced techniques of treatment delivery. The previously applied extended field (EF) and original involved field (IF) techniques, which treated larger volumes based on nodal stations, have now been replaced by the use of limited volumes, based solelymore » on detectable nodal (and extranodal extension) involvement at presentation, using contrast-enhanced computed tomography, positron emission tomography/computed tomography, magnetic resonance imaging, or a combination of these techniques. The International Commission on Radiation Units and Measurements concepts of gross tumor volume, clinical target volume, internal target volume, and planning target volume are used for defining the targeted volumes. Newer treatment techniques, including intensity modulated radiation therapy, breath-hold, image guided radiation therapy, and 4-dimensional imaging, should be implemented when their use is expected to decrease significantly the risk for normal tissue damage while still achieving the primary goal of local tumor control. The highly conformal involved node radiation therapy (INRT), recently introduced for patients for whom optimal imaging is available, is explained. A new concept, involved site radiation therapy (ISRT), is introduced as the standard conformal therapy for the scenario, commonly encountered, wherein optimal imaging is not available. There is increasing evidence that RT doses used in the past are higher than necessary for disease control in this era of combined modality therapy. The use of INRT and of lower doses in early-stage HL is supported by available data. Although the use of ISRT has not yet been validated in a formal study, it is more conservative than INRT, accounting for suboptimal information and appropriately designed for safe local disease control. The goal of modern smaller field radiation therapy is to reduce both treatment volume and treatment dose while maintaining efficacy and minimizing acute and late sequelae. This review is a consensus of the International Lymphoma Radiation Oncology Group (ILROG) Steering Committee regarding the modern approach to RT in the treatment of HL, outlining a new concept of ISRT in which reduced treatment volumes are planned for the effective control of involved sites of HL. Nodal and extranodal non-Hodgkin lymphomas (NHL) are covered separately by ILROG guidelines.« less
Specht, Lena; Yahalom, Joachim; Illidge, Tim; Berthelsen, Anne Kiil; Constine, Louis S; Eich, Hans Theodor; Girinsky, Theodore; Hoppe, Richard T; Mauch, Peter; Mikhaeel, N George; Ng, Andrea
2014-07-15
Radiation therapy (RT) is the most effective single modality for local control of Hodgkin lymphoma (HL) and an important component of therapy for many patients. These guidelines have been developed to address the use of RT in HL in the modern era of combined modality treatment. The role of reduced volumes and doses is addressed, integrating modern imaging with 3-dimensional (3D) planning and advanced techniques of treatment delivery. The previously applied extended field (EF) and original involved field (IF) techniques, which treated larger volumes based on nodal stations, have now been replaced by the use of limited volumes, based solely on detectable nodal (and extranodal extension) involvement at presentation, using contrast-enhanced computed tomography, positron emission tomography/computed tomography, magnetic resonance imaging, or a combination of these techniques. The International Commission on Radiation Units and Measurements concepts of gross tumor volume, clinical target volume, internal target volume, and planning target volume are used for defining the targeted volumes. Newer treatment techniques, including intensity modulated radiation therapy, breath-hold, image guided radiation therapy, and 4-dimensional imaging, should be implemented when their use is expected to decrease significantly the risk for normal tissue damage while still achieving the primary goal of local tumor control. The highly conformal involved node radiation therapy (INRT), recently introduced for patients for whom optimal imaging is available, is explained. A new concept, involved site radiation therapy (ISRT), is introduced as the standard conformal therapy for the scenario, commonly encountered, wherein optimal imaging is not available. There is increasing evidence that RT doses used in the past are higher than necessary for disease control in this era of combined modality therapy. The use of INRT and of lower doses in early-stage HL is supported by available data. Although the use of ISRT has not yet been validated in a formal study, it is more conservative than INRT, accounting for suboptimal information and appropriately designed for safe local disease control. The goal of modern smaller field radiation therapy is to reduce both treatment volume and treatment dose while maintaining efficacy and minimizing acute and late sequelae. This review is a consensus of the International Lymphoma Radiation Oncology Group (ILROG) Steering Committee regarding the modern approach to RT in the treatment of HL, outlining a new concept of ISRT in which reduced treatment volumes are planned for the effective control of involved sites of HL. Nodal and extranodal non-Hodgkin lymphomas (NHL) are covered separately by ILROG guidelines. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheon, G; Kang, Y; Kang, S
Purpose: Hippocampus is one of the important organs which controls emotions, behaviors, movements the memorizing and learning ability. In the conventional head & neck therapy position, it is difficult to perform the hippocampal-sparing brain radiation therapy. The purpose of this study is to investigate optimal head angle which can save the hippocampal-sparing and organ at risk (OAR) in conformal radiation therapy (CRT), Intensity modulation radiation therapy (IMRT) and helical tomotherapy (HT). Methods: Three types of radiation treatment plans, CRT, IMRT and Tomotherapy plans, were performed for 10 brain tumor patients. The image fusion between CT and MRI data were usedmore » in the contour due to the limited delineation of the target and OAR in the CT scan. The optimal condition plan was determined by comparing the dosimetric performance of the each plan with the use of various parameters which include three different techniques (CRT, IMRT, HT) and 4 angle (0, 15, 30, 40 degree). The each treatment plans of three different techniques were compared with the following parameters: conformity index (CI), homogeneity index (HI), target coverage, dose in the OARs, monitor units (MU), beam on time and the normal tissue complication probability (NTCP). Results: HI, CI and target coverage was most excellent in head angle 30 degree among all angle. When compared by modality, target coverage and CI showed good results in IMRT and TOMO than compared to the CRT. HI at the head angle 0 degrees is 1.137±0.17 (CRT), 1.085±0.09 (IMRT) and 1.077±0.06 (HT). HI at the head angle 30 degrees is 1.056±0.08 (CRT), 1.020±0.05 (IMRT) and 1.022±0.07 (HT). Conclusion: The results of our study show that when head angle tilted at 30 degree, target coverage, HI, CI were improved, and the dose delivered to OAR was reduced compared with conventional supine position in brain radiation therapy. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.« less
In vivo demonstration of enhanced radiotherapy using rare earth doped titania nanoparticles.
Townley, Helen E; Kim, Jeewon; Dobson, Peter J
2012-08-21
Radiation therapy is often limited by damage to healthy tissue and associated side-effects; restricting radiation to ineffective doses. Preferential incorporation of materials into tumour tissue can enhance the effect of radiation. Titania has precedent for use in photodynamic therapy (PDT), generating reactive oxygen species (ROS) upon photoexcitation, but is limited by the penetration depth of UV light. Optimization of a nanomaterial for interaction with X-rays could be used for deep tumour treatment. As such, titania nanoparticles were doped with gadolinium to optimize the localized energy absorption from a conventional medical X-ray, and further optimized by the addition of other rare earth (RE) elements. These elements were selected due to their large X-ray photon interaction cross-section, and potential for integration into the titania crystal structure. Specific activation of the nanoparticles by X-ray can result in generation of ROS leading to cell death in a tumour-localized manner. We show here that intratumoural injection of RE doped titania nanoparticles can enhance the efficacy of radiotherapy in vivo.
Incorporating uncertainty and motion in Intensity Modulated Radiation Therapy treatment planning
NASA Astrophysics Data System (ADS)
Martin, Benjamin Charles
In radiation therapy, one seeks to destroy a tumor while minimizing the damage to surrounding healthy tissue. Intensity Modulated Radiation Therapy (IMRT) uses overlapping beams of x-rays that add up to a high dose within the target and a lower dose in the surrounding healthy tissue. IMRT relies on optimization techniques to create high quality treatments. Unfortunately, the possible conformality is limited by the need to ensure coverage even if there is organ movement or deformation. Currently, margins are added around the tumor to ensure coverage based on an assumed motion range. This approach does not ensure high quality treatments. In the standard IMRT optimization problem, an objective function measures the deviation of the dose from the clinical goals. The optimization then finds the beamlet intensities that minimize the objective function. When modeling uncertainty, the dose delivered from a given set of beamlet intensities is a random variable. Thus the objective function is also a random variable. In our stochastic formulation we minimize the expected value of this objective function. We developed a problem formulation that is both flexible and fast enough for use on real clinical cases. While working on accelerating the stochastic optimization, we developed a technique of voxel sampling. Voxel sampling is a randomized algorithms approach to a steepest descent problem based on estimating the gradient by only calculating the dose to a fraction of the voxels within the patient. When combined with an automatic sampling rate adaptation technique, voxel sampling produced an order of magnitude speed up in IMRT optimization. We also develop extensions of our results to Intensity Modulated Proton Therapy (IMPT). Due to the physics of proton beams the stochastic formulation yields visibly different and better plans than normal optimization. The results of our research have been incorporated into a software package OPT4D, which is an IMRT and IMPT optimization tool that we developed.
Rectal cancer: An evidence-based update for primary care providers
Gaertner, Wolfgang B; Kwaan, Mary R; Madoff, Robert D; Melton, Genevieve B
2015-01-01
Rectal adenocarcinoma is an important cause of cancer-related deaths worldwide, and key anatomic differences between the rectum and the colon have significant implications for management of rectal cancer. Many advances have been made in the diagnosis and management of rectal cancer. These include clinical staging with imaging studies such as endorectal ultrasound and pelvic magnetic resonance imaging, operative approaches such as transanal endoscopic microsurgery and laparoscopic and robotic assisted proctectomy, as well as refined neoadjuvant and adjuvant therapies. For stage II and III rectal cancers, combined chemoradiotherapy offers the lowest rates of local and distant relapse, and is delivered neoadjuvantly to improve tolerability and optimize surgical outcomes, particularly when sphincter-sparing surgery is an endpoint. The goal in rectal cancer treatment is to optimize disease-free and overall survival while minimizing the risk of local recurrence and toxicity from both radiation and systemic therapy. Optimal patient outcomes depend on multidisciplinary involvement for tailored therapy. The successful management of rectal cancer requires a multidisciplinary approach, with the involvement of enterostomal nurses, gastroenterologists, medical and radiation oncologists, radiologists, pathologists and surgeons. The identification of patients who are candidates for combined modality treatment is particularly useful to optimize outcomes. This article provides an overview of the diagnosis, staging and multimodal therapy of patients with rectal cancer for primary care providers. PMID:26167068
NASA Astrophysics Data System (ADS)
Altman, Michael B.
The increasing prevalence of intensity modulated radiation therapy (IMRT) as a treatment modality has led to a renewed interest in the potential for interaction between prolonged treatment time, as frequently associated with IMRT, and the underlying radiobiology of the irradiated tissue. A particularly relevant aspect of radiobiology is cell repair capacity, which influences cell survival, and thus directly relates to the ability to control tumors and spare normal tissues. For a single fraction of radiation, the linear quadratic (LQ) model is commonly used to relate the radiation dose to the fraction of cells surviving. The LQ model implies a dependence on two time-related factors which correlate to radiobiological effects: the duration of radiation application, and the functional form of how the dose is applied over that time (the "temporal pattern of applied dose"). Although the former has been well studied, the latter has not. Thus, the goal of this research is to investigate the impact of the temporal pattern of applied dose on the survival of human cells and to explore how the manipulation of this temporal dose pattern may be incorporated into an IMRT-based radiation therapy treatment planning scheme. The hypothesis is that the temporal pattern of applied dose in a single fraction of radiation can be optimized to maximize or minimize cell kill. Furthermore, techniques which utilize this effect could have clinical ramifications. In situations where increased cell kill is desirable, such as tumor control, or limiting the degree of cell kill is important, such as the sparing of normal tissue, temporal sequences of dose which maximize or minimize cell kill (temporally "optimized" sequences) may provide greater benefit than current clinically used radiation patterns. In the first part of this work, an LQ-based modeling analysis of effects of the temporal pattern of dose on cell kill is performed. Through this, patterns are identified for maximizing cell kill for a given radiation pattern by concentrating the highest doses in the middle of a fraction (a "Triangle" pattern), or minimizing cell kill by placing the highest doses near the beginning and end (a "V-shaped" pattern). The conditions under which temporal optimization effects are most acute are also identified: irradiation of low alpha/beta tissues, long fraction durations, and high doses/fx. An in vitro study is then performed which verifies that the temporal effects and trends predicted by the modeling study are clearly manifested in human cells. Following this a phantom which could allow similar in vitro radiobiological experiments in a 3-dimensional clinically-based environment is designed, created, and dosimetrically assessed using TLDs, film, and biological assay-based techniques. The phantom is found to be a useful and versatile tool for such experiments. A scheme for utilizing the phantom in a clinical treatment environment is then developed. This includes a demonstration of prototype methods for optimizing the temporal pattern of applied dose in clinical IMRT plans to manipulate tissue-dependent effects. Looking toward future experimental validation of such plans using the phantom, an analysis of the suitability of biological assays for use in phantom-based in vitro experiments is performed. Finally, a discussion is provided about the steps necessary to integrate temporal optimization into in vivo experiments and ultimately into a clinical radiation therapy environment. If temporal optimization is ultimately shown to have impact in vivo, the successful implementation of the methods developed in this study could enhance the efficacy and care of thousands of patients receiving radiotherapy.
Shi, Shiming; Zeng, Zhaochong; Ye, Luxi; Huang, Yan; He, Jian
2017-06-01
Radiation pneumonitis is the most frequent acute pulmonary toxicity following stereotactic body radiation therapy for lung cancer. Here, we investigate clinical and dosimetric factors associated with symptomatic radiation pneumonitis in patients with stage I non-small cell lung cancer treated with stereotactic body radiation therapy. A total of 67 patients with stage I non-small cell lung cancer who received stereotactic body radiation therapy at our institution were enrolled, and their clinicopathological parameters and dosimetric parameters were recorded and analyzed. The median follow-up period was 26.4 months (range: 7-48 months). In univariate analysis, tumor size ( P = .041), mean lung dose ( P = .028), V2.5 ( P = .024), V5 ( P = .014), V10 ( P = .004), V20 ( P = .024), V30 ( P = .020), V40 ( P = .040), and V50 ( P = 0.040) were associated with symptomatic radiation pneumonitis. In multivariable logistic regression analysis, V10 ( P = .049) was significantly associated with symptomatic radiation pneumonitis. In conclusion, this study found that tumor size, mean lung dose, and V2.5 to V50 were risk factors markedly associated with symptomatic radiation pneumonitis. Our data suggested that lung V10 was the most significant factor, and optimizing lung V10 may reduce the risk of symptomatic radiation pneumonitis. For both central and peripheral stage I lung cancer, rate of radiation pneumonitis ≥grade 2 was low after stereotactic body radiation therapy with appropriate fraction dose.
Ishibashi, Naoya; Hata, Masaharu; Mochizuki, Takao; Ogawa, Kogi; Sugiura, Hiroaki; Takekawa, Yoshinori; Maebayashi, Toshiya; Aizawa, Takuya; Sakaguchi, Masakuni; Abe, Osamu
2016-10-01
Primary breast lymphoma is a rare type of non-Hodgkin lymphoma and usually affects women, although a few cases have been reported in men. Chemotherapy and radiation therapy, or a combination of both, are frequently administered for treatment of primary breast lymphoma, as local control by surgical resection is poor. No standard therapy has been established, and the optimal radiation dose and irradiation field for male patients are unknown. The present report describes a 75-year-old man with bilateral cirrhosis-induced gynecomastia who was diagnosed with primary breast lymphoma; specifically, diffuse large B-cell lymphoma. Because of his hepatic dysfunction, he was treated with radiation therapy alone. Radiation therapy was followed by eight cycles of rituximab monotherapy. Clinical response was good, with no signs of relapse. Clinicians may benefit from knowledge regarding effective treatment of primary breast lymphoma in male patients, which has been rarely reported owing to the low incidence of this condition. The outcome in the present case may help to establish effective treatment guidelines in similar cases.
The promise of dynamic contrast-enhanced imaging in radiation therapy.
Cao, Yue
2011-04-01
Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and computed tomography (CT) scanning are emerging as valuable tools to quantitatively map the spatial distribution of vascular parameters, such as perfusion, vascular permeability, blood volume, and mean transit time in tumors and normal organs. DCE MRI/CT have shown prognostic and predictive value for response of certain cancers to chemotherapy and radiation therapy. DCE MRI/CT offer the promise of early assessment of tumor response to radiation therapy, opening a window for adaptively optimizing radiation therapy based upon functional alterations that occur earlier than morphologic changes. DCE MRI/CT has also shown the potential of mapping dose responses in normal organs and tissue for evaluation of individual sensitivity to radiation, providing additional opportunities to minimize risks of radiation injury. The evidence for potentially applying DCE MRI and CT for selection and delineation of radiation boost targets is growing. The clinical use of DCE MRI and CT scanning as a biomarker or even a surrogate endpoint for radiation therapy assessment of tumor and normal organs must consider technical validation issues, including standardization, reproducibility, accuracy and robustness, and clinical validation of the sensitivity and specificity for each specific problem of interest. Although holding great promise, to date, DCE MRI and CT scanning have not been qualified as a surrogate endpoint for radiation therapy assessment or for treatment modification in any prospective phase III clinical trial for any tumor site. Copyright © 2011 Elsevier Inc. All rights reserved.
Florczynski, Matthew M; Sanatani, Michael S; Mai, Lauren; Fisher, Barbara; Moulin, Dwight E; Cao, Jeffrey; Louie, Alexander V; Pope, Janet E; Leung, Eric
2016-03-22
The use of neoadjuvant radiation therapy and chemotherapy in the treatment of locally advanced rectal adenocarcinoma has been shown to reduce disease recurrence when combined with surgery and adjuvant chemotherapy. We report a case of a patient who developed a debilitating bilateral myopathy of the hip flexors after successful treatment for rectal cancer. To the best of our knowledge, this is the first such complication from radiation therapy reported in a patient with colorectal cancer. The disproportionate severity of our patient's myopathy relative to the dose of radiation used also makes this case unique among reports of neuromuscular complications from radiation therapy. The patient is a 65-year-old male with node negative, high-grade adenocarcinoma of the rectum penetrating through the distal rectal wall. He underwent neoadjuvant concurrent pelvic radiation therapy and capecitabine-based chemotherapy, followed by abdominoperineal resection and post-operative FOLFOX chemotherapy. Five months post-completion of pelvic radiotherapy and 2 months after the completion of adjuvant chemotherapy, he presented with bilateral weakness of the iliopsoas muscles and severe pain radiating to the groin. The patient improved with 40 mg/d of prednisone, which was gradually tapered to 2 mg/d over 6 months, with substantial recovery of muscle strength and elimination of pain. The timing, presentation and response of our patient's symptoms to corticosteroids are most consistent with a radiation recall reaction. Radiation recall is a phenomenon whereby previously irradiated tissue becomes vulnerable to toxicity by subsequent systemic therapy and is rarely associated with myopathies. Radiation recall should be considered a potential complication of neoadjuvant radiation therapy for rectal cancer, and for ongoing research into the optimization of treatment for these patients. Severe myopathies caused by radiation recall may be fully reversible with corticosteroid treatment.
NASA Astrophysics Data System (ADS)
Sukhikh, E.; Sheino, I.; Vertinsky, A.
2017-09-01
Modern modalities of radiation treatment therapy allow irradiation of the tumor to high dose values and irradiation of organs at risk (OARs) to low dose values at the same time. In this paper we study optimal radiation treatment plans made in Monaco system. The first aim of this study was to evaluate dosimetric features of Monaco treatment planning system using biological versus dose-based cost functions for the OARs and irradiation targets (namely tumors) when the full potential of built-in biological cost functions is utilized. The second aim was to develop criteria for the evaluation of radiation dosimetry plans for patients based on the macroscopic radiobiological criteria - TCP/NTCP. In the framework of the study four dosimetric plans were created utilizing the full extent of biological and physical cost functions using dose calculation-based treatment planning for IMRT Step-and-Shoot delivery of stereotactic body radiation therapy (SBRT) in prostate case (5 fractions per 7 Gy).
Comparison of optimization algorithms in intensity-modulated radiation therapy planning
NASA Astrophysics Data System (ADS)
Kendrick, Rachel
Intensity-modulated radiation therapy is used to better conform the radiation dose to the target, which includes avoiding healthy tissue. Planning programs employ optimization methods to search for the best fluence of each photon beam, and therefore to create the best treatment plan. The Computational Environment for Radiotherapy Research (CERR), a program written in MATLAB, was used to examine some commonly-used algorithms for one 5-beam plan. Algorithms include the genetic algorithm, quadratic programming, pattern search, constrained nonlinear optimization, simulated annealing, the optimization method used in Varian EclipseTM, and some hybrids of these. Quadratic programing, simulated annealing, and a quadratic/simulated annealing hybrid were also separately compared using different prescription doses. The results of each dose-volume histogram as well as the visual dose color wash were used to compare the plans. CERR's built-in quadratic programming provided the best overall plan, but avoidance of the organ-at-risk was rivaled by other programs. Hybrids of quadratic programming with some of these algorithms seems to suggest the possibility of better planning programs, as shown by the improved quadratic/simulated annealing plan when compared to the simulated annealing algorithm alone. Further experimentation will be done to improve cost functions and computational time.
Censor, Yair; Unkelbach, Jan
2012-04-01
In this paper we look at the development of radiation therapy treatment planning from a mathematical point of view. Historically, planning for Intensity-Modulated Radiation Therapy (IMRT) has been considered as an inverse problem. We discuss first the two fundamental approaches that have been investigated to solve this inverse problem: Continuous analytic inversion techniques on one hand, and fully-discretized algebraic methods on the other hand. In the second part of the paper, we review another fundamental question which has been subject to debate from the beginning of IMRT until the present day: The rotation therapy approach versus fixed angle IMRT. This builds a bridge from historic work on IMRT planning to contemporary research in the context of Intensity-Modulated Arc Therapy (IMAT). Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Camingue, Pamela; Christian, Rochelle; Ng, Davin
The purpose of this study was to compare 4 different external beam radiation therapy treatment techniques for the treatment of T1-2, N0, M0 glottic cancers: traditional lateral beams with wedges (3D), 5-field intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT), and proton therapy. Treatment plans in each technique were created for 10 patients using consistent planning parameters. The photon treatment plans were optimized using Philips Pinnacle{sub 3} v.9 and the IMRT and VMAT plans used the Direct Machine Parameter Optimization algorithm. The proton treatment plans were optimized using Varian Eclipse Proton v.8.9. The prescription used for each plan wasmore » 63 Gy in 28 fractions. The contours for spinal cord, right carotid artery, left carotid artery, and normal tissue were created with respect to the patient's bony anatomy so that proper comparisons of doses could be made with respect to volume. An example of the different isodose distributions will be shown. The data collection for comparison purposes includes: clinical treatment volume coverage, dose to spinal cord, dose to carotid arteries, and dose to normal tissue. Data comparisons will be displayed graphically showing the maximum, mean, median, and ranges of doses.« less
NASA Astrophysics Data System (ADS)
Hoffmann, Aswin L.; den Hertog, Dick; Siem, Alex Y. D.; Kaanders, Johannes H. A. M.; Huizenga, Henk
2008-11-01
Finding fluence maps for intensity-modulated radiation therapy (IMRT) can be formulated as a multi-criteria optimization problem for which Pareto optimal treatment plans exist. To account for the dose-per-fraction effect of fractionated IMRT, it is desirable to exploit radiobiological treatment plan evaluation criteria based on the linear-quadratic (LQ) cell survival model as a means to balance the radiation benefits and risks in terms of biologic response. Unfortunately, the LQ-model-based radiobiological criteria are nonconvex functions, which make the optimization problem hard to solve. We apply the framework proposed by Romeijn et al (2004 Phys. Med. Biol. 49 1991-2013) to find transformations of LQ-model-based radiobiological functions and establish conditions under which transformed functions result in equivalent convex criteria that do not change the set of Pareto optimal treatment plans. The functions analysed are: the LQ-Poisson-based model for tumour control probability (TCP) with and without inter-patient heterogeneity in radiation sensitivity, the LQ-Poisson-based relative seriality s-model for normal tissue complication probability (NTCP), the equivalent uniform dose (EUD) under the LQ-Poisson model and the fractionation-corrected Probit-based model for NTCP according to Lyman, Kutcher and Burman. These functions differ from those analysed before in that they cannot be decomposed into elementary EUD or generalized-EUD functions. In addition, we show that applying increasing and concave transformations to the convexified functions is beneficial for the piecewise approximation of the Pareto efficient frontier.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, I; Algan, O; Ahmad, S
Purpose: To model patient motion and produce four-dimensional (4D) optimized dose distributions that consider motion-artifacts in the dose calculation during the treatment planning process. Methods: An algorithm for dose calculation is developed where patient motion is considered in dose calculation at the stage of the treatment planning. First, optimal dose distributions are calculated for the stationary target volume where the dose distributions are optimized considering intensity-modulated radiation therapy (IMRT). Second, a convolution-kernel is produced from the best-fitting curve which matches the motion trajectory of the patient. Third, the motion kernel is deconvolved with the initial dose distribution optimized for themore » stationary target to produce a dose distribution that is optimized in four-dimensions. This algorithm is tested with measured doses using a mobile phantom that moves with controlled motion patterns. Results: A motion-optimized dose distribution is obtained from the initial dose distribution of the stationary target by deconvolution with the motion-kernel of the mobile target. This motion-optimized dose distribution is equivalent to that optimized for the stationary target using IMRT. The motion-optimized and measured dose distributions are tested with the gamma index with a passing rate of >95% considering 3% dose-difference and 3mm distance-to-agreement. If the dose delivery per beam takes place over several respiratory cycles, then the spread-out of the dose distributions is only dependent on the motion amplitude and not affected by motion frequency and phase. This algorithm is limited to motion amplitudes that are smaller than the length of the target along the direction of motion. Conclusion: An algorithm is developed to optimize dose in 4D. Besides IMRT that provides optimal dose coverage for a stationary target, it extends dose optimization to 4D considering target motion. This algorithm provides alternative to motion management techniques such as beam-gating or breath-holding and has potential applications in adaptive radiation therapy.« less
Mahé, M-A; Barillot, I; Chauvet, B
2014-10-01
In 2007, a first edition was published with the objective to produce guidelines for optimization, harmonization and homogenization of practices in external radiation therapy in France. The second edition, including brachytherapy, has the same objective and takes into account recent technologic improvements (intensity modulation radiation therapy, stereotactic radiotherapy, and 3-dimension brachytherapy) and recent results of the literature. The first part is about daily use of general principles (quality, security, image-guided radiation therapy) and the second is to describe each step of treatment of main cancers. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
In vivo demonstration of enhanced radiotherapy using rare earth doped titania nanoparticles†
Townley, Helen E.; Kim, Jeewon; Dobson, Peter J.
2017-01-01
Radiation therapy is often limited by damage to healthy tissue and associated side-effects; restricting radiation to ineffective doses. Preferential incorporation of materials into tumour tissue can enhance the effect of radiation. Titania has precedent for use in photodynamic therapy (PDT), generating reactive oxygen species (ROS) upon photoexcitation, but is limited by the penetration depth of UV light. Optimization of a nanomaterial for interaction with X-rays could be used for deep tumour treatment. As such, titania nanoparticles were doped with gadolinium to optimize the localized energy absorption from a conventional medical X-ray, and further optimized by the addition of other rare earth (RE) elements. These elements were selected due to their large X-ray photon interaction cross-section, and potential for integration into the titania crystal structure. Specific activation of the nanoparticles by X-ray can result in generation of ROS leading to cell death in a tumour-localized manner. We show here that intratumoural injection of RE doped titania nanoparticles can enhance the efficacy of radiotherapy in vivo. PMID:22767269
Chevrollier, Guillaume S.; Greaney, Patrick J.; Jenkins, Matthew P.; Copit, Steven E.
2017-01-01
Objective: Postmastectomy radiation therapy is a well-established risk factor for complications after breast reconstruction. Even if the surgeon has a suspicion that radiation therapy may be needed, it may be beneficial to place tissue expanders during the mastectomy procedure as a temporizing measure, complete radiation therapy, and then reconstruct the breast with a latissimus flap. The purpose of this study was to examine the complication rates of the latissimus dorsi flap as compared with the complication rates of implant-based reconstruction in the setting of radiation therapy. Methods: A 16-year retrospective chart review from 2000 to 2016 was conducted. All patients who underwent temporizing tissue expander placement for radiotherapy with subsequent latissimus flap reconstruction were included in the study. Patients who did not follow up for implant exchange were excluded from the study. Results: Fifty-five patients were identified with an average age of 46.0 years (range, 27-67 years) and an average body mass index of 24.2 (range, 18.9-31.9). Five patients (9.1%) developed capsular contractures amenable to surgical intervention. One patient (1.8%) developed infection of the tissue expander, requiring removal. There were no incidences of flap failure or wound dehiscence. The average follow-up after latissimus flap reconstruction was 25.3 months (range, 3.7-121.6 months). Conclusions: We feel that the latissimus dorsi flap after postmastectomy radiation therapy represents the preferred implant-based reconstruction option to consider when the need for postmastectomy radiation therapy is anticipated. The latissimus dorsi flap remains a safe, effective solution to postmastectomy radiation therapy that every plastic surgeon should offer. PMID:29308108
Mohiuddin, Waseem; Chevrollier, Guillaume S; Greaney, Patrick J; Jenkins, Matthew P; Copit, Steven E
2017-01-01
Objective: Postmastectomy radiation therapy is a well-established risk factor for complications after breast reconstruction. Even if the surgeon has a suspicion that radiation therapy may be needed, it may be beneficial to place tissue expanders during the mastectomy procedure as a temporizing measure, complete radiation therapy, and then reconstruct the breast with a latissimus flap. The purpose of this study was to examine the complication rates of the latissimus dorsi flap as compared with the complication rates of implant-based reconstruction in the setting of radiation therapy. Methods: A 16-year retrospective chart review from 2000 to 2016 was conducted. All patients who underwent temporizing tissue expander placement for radiotherapy with subsequent latissimus flap reconstruction were included in the study. Patients who did not follow up for implant exchange were excluded from the study. Results: Fifty-five patients were identified with an average age of 46.0 years (range, 27-67 years) and an average body mass index of 24.2 (range, 18.9-31.9). Five patients (9.1%) developed capsular contractures amenable to surgical intervention. One patient (1.8%) developed infection of the tissue expander, requiring removal. There were no incidences of flap failure or wound dehiscence. The average follow-up after latissimus flap reconstruction was 25.3 months (range, 3.7-121.6 months). Conclusions: We feel that the latissimus dorsi flap after postmastectomy radiation therapy represents the preferred implant-based reconstruction option to consider when the need for postmastectomy radiation therapy is anticipated. The latissimus dorsi flap remains a safe, effective solution to postmastectomy radiation therapy that every plastic surgeon should offer.
Basic immunology of antibody targeted radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, Jeffrey Y.C.
2006-10-01
Antibody targeted radiotherapy brings an important new treatment modality to Radiation oncology clinic. Radiation dose to tumor and normal tissues are determined by a complex interplay of antibody, antigen, tumor, radionuclide, and host-related factors. A basic understanding of these immunologic and physiologic factors is important to optimally utilize this therapy in the clinic. Preclinical and clinical studies need to be continued to broaden our understanding and to develop new strategies to further improve the efficacy of this promising form of targeted therapy.
2005-06-01
subsequently trigger a cascade of tumor cell death in experimental tumors [4,5]. Although massive necrosis can be induced, tumors usually regrow from a...the Statement of Work Task 2, experimental radiation therapy has been designed and initiated based on the MRI oximetry data. Preliminary data of control...Hoechst dye 33342 showed a significant reduction in perfused vessels at 2hr after CA4P, which recovered 24 h later. * Experimental radiation therapy a
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warren, Laura E.G.; Punglia, Rinaa S.; Wong, Julia S.
2014-11-15
Radiation therapy to the breast following breast conservation surgery has been the standard of care since randomized trials demonstrated equivalent survival compared to mastectomy and improved local control and survival compared to breast conservation surgery alone. Recent controversies regarding adjuvant radiation therapy have included the potential role of additional radiation to the regional lymph nodes. This review summarizes the evolution of regional nodal management focusing on 2 topics: first, the changing paradigm with regard to surgical evaluation of the axilla; second, the role for regional lymph node irradiation and optimal design of treatment fields. Contemporary data reaffirm prior studies showingmore » that complete axillary dissection may not provide additional benefit relative to sentinel lymph node biopsy in select patient populations. Preliminary data also suggest that directed nodal radiation therapy to the supraclavicular and internal mammary lymph nodes may prove beneficial; publication of several studies are awaited to confirm these results and to help define subgroups with the greatest likelihood of benefit.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sonier, Marcus, E-mail: Marcus.Sonier@bccancer.bc.ca; Chu, William; Department of Radiation Oncology, University of Toronto, Toronto, ON
To develop a volumetric modulated arc therapy (VMAT) treatment planning solution in the treatment of primary renal cell carcinoma and oligometastatic adrenal lesions with stereotactic body radiation therapy. Single-arc VMAT plans (n = 5) were compared with clinically delivered step-and-shoot intensity-modulated radiotherapy (IMRT) with planning target volume coverage normalized between techniques. Target volume conformity, organ-at-risk (OAR) dose, treatment time, and monitor units were compared. A VMAT planning solution, created from a combination of arc settings and optimization constraints, auto-generated treatment plans in a single optimization. The treatment planning solution was evaluated on 15 consecutive patients receiving kidney and adrenal stereotacticmore » body radiation therapy. Treatment time was reduced from 13.0 ± 2.6 to 4.0 ± 0.9 minutes for IMRT and VMAT, respectively. The VMAT planning solution generated treatment plans with increased target homogeneity, improved 95% conformity index, and a reduced maximum point dose to nearby OARs but with increased intermediate dose to distant OARs. The conformity of the 95% isodose improved from 1.32 ± 0.39 to 1.12 ± 0.05 for IMRT and VMAT treatment plans, respectively. Evaluation of the planning solution showed clinically acceptable dose distributions for 13 of 15 cases with tight conformity of the prescription isodose to the planning target volume of 1.07 ± 0.04, delivering minimal dose to OARs. The introduction of a stereotactic body radiation therapy VMAT treatment planning solution improves the efficiency of planning and delivery time, producing treatment plans of comparable or superior quality to IMRT in the case of primary renal cell carcinoma and oligometastatic adrenal lesions.« less
NASA Astrophysics Data System (ADS)
Lee, Jae-Seung; Im, In-Chul; Kang, Su-Man; Goo, Eun-Hoe; Baek, Seong-Min
2013-11-01
The aim of this study was to quantitatively analyze the changes in the planning target volume (PTV) and liver volume dose based on the respiratory phase to identify the optimal respiratory phase for respiratory-gated radiation therapy for a hepatocellular carcinoma (HCC). Based on the standardized procedure for respiratory-gated radiation therapy, we performed a 4-dimensional computed tomography simulation for 0 ˜ 90%, 30 ˜ 70%, and 40 ˜ 60% respiratory phases to assess the respiratory stability (S R ) and the defined PTV i for each respiratory phase i. A treatment plan was established, and the changes in the PTV i and dose volume of the liver were quantitatively analyzed. Most patients (91.5%) passed the respiratory stability test (S R = 0.111 ± 0.015). With standardized respiration training exercises, we were able to minimize the overall systematic error caused by irregular respiration. Furthermore, a quantitative analysis to identify the optimal respiratory phase revealed that when a short respiratory phase (40 ˜ 60%) was used, the changes in the PTV were concentrated inside the center line; thus, we were able to obtain both a PTV margin accounting for respiration and a uniform radiation dose within the PTV.
MO-E-BRE-01: Determination, Minimization and Communication of Uncertainties in Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Dyk, J; Palta, J; Bortfeld, T
2014-06-15
Medical Physicists have a general understanding of uncertainties in the radiation treatment process, both with respect to dosimetry and geometry. However, there is a desire to be more quantitative about uncertainty estimation. A recent International Atomic Energy Agency (IAEA) report (about to be published) recommends that we should be as “accurate as reasonably achievable, technical and biological factors being taken into account”. Thus, a single recommendation as a goal for accuracy in radiation therapy is an oversimplification. That report also suggests that individual clinics should determine their own level of uncertainties for their specific treatment protocols. The question is “howmore » do we implement this in clinical practice”? AAPM Monograph 35 (2011 AAPM Summer School) addressed many specific aspects of uncertainties in each of the steps of a course of radiation treatment. The intent of this symposium is: (1) to review uncertainty considerations in the entire radiation treatment process including uncertainty determination for each step and uncertainty propagation for the total process, (2) to consider aspects of robust optimization which optimizes treatment plans while protecting them against uncertainties, and (3) to describe various methods of displaying uncertainties and communicating uncertainties to the relevant professionals. While the theoretical and research aspects will also be described, the emphasis will be on the practical considerations for the medical physicist in clinical practice. Learning Objectives: To review uncertainty determination in the overall radiation treatment process. To consider uncertainty modeling and uncertainty propagation. To highlight the basic ideas and clinical potential of robust optimization procedures to generate optimal treatment plans that are not severely affected by uncertainties. To describe methods of uncertainty communication and display.« less
Han, Eun Young; Paudel, Nava; Sung, Jiwon; Yoon, Myonggeun; Chung, Weon Kuu; Kim, Dong Wook
2016-04-19
The risk of secondary cancer from radiation treatment remains a concern for long-term breast cancer survivors, especially those treated with radiation at the age younger than 45 years. Treatment modalities optimally maximize the dose delivery to the tumor while minimizing radiation doses to neighboring organs, which can lead to secondary cancers. A new TomoTherapy treatment machine, TomoHDATM, can treat an entire breast with two static but intensity-modulated beams in a slice-by-slice fashion. This feature could reduce scattered and leakage radiation doses. We compared the plan quality and lifetime attributable risk (LAR) of a second malignancy among five treatment modalities: three-dimensional conformal radiation therapy, field-in-field forward-planned intensity-modulated radiation therapy, inverse-planned intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy, and TomoDirect mode on the TomoHDA system. Ten breast cancer patients were selected for retrospective analysis. Organ equivalent doses, plan characteristics, and LARs were compared. Out-of-field organ doses were measured with radio-photoluminescence glass dosimeters. Although the IMRT plan provided overall better plan quality, including the lowest probability of pneumonitis, it caused the second highest LAR. The TomoTherapy plan provided plan quality comparable to the IMRT plan and posed the lowest total LAR to neighboring organs. Therefore, it can be a better treatment modality for younger patients who have a longer life expectancy.
Weber, Damien C; Ares, Carmen; Lomax, Antony J; Kurtz, John M
2006-01-01
Postoperative radiation therapy substantially decreases local relapse and moderately reduces breast cancer mortality, but can be associated with increased late mortality due to cardiovascular morbidity and secondary malignancies. Sophistication of breast irradiation techniques, including conformal radiotherapy and intensity modulated radiation therapy, has been shown to markedly reduce cardiac and lung irradiation. The delivery of more conformal treatment can also be achieved with particle beam therapy using protons. Protons have superior dose distributional qualities compared to photons, as dose deposition occurs in a modulated narrow zone, called the Bragg peak. As a result, further dose optimization in breast cancer treatment can be reasonably expected with protons. In this review, we outline the potential indications and benefits of breast cancer radiotherapy with protons. Comparative planning studies and preliminary clinical data are detailed and future developments are considered. PMID:16857055
Current approaches to the treatment of metastatic brain tumours
Owonikoko, Taofeek K.; Arbiser, Jack; Zelnak, Amelia; Shu, Hui-Kuo G.; Shim, Hyunsuk; Robin, Adam M.; Kalkanis, Steven N.; Whitsett, Timothy G.; Salhia, Bodour; Tran, Nhan L.; Ryken, Timothy; Moore, Michael K.; Egan, Kathleen M.; Olson, Jeffrey J.
2014-01-01
Metastatic tumours involving the brain overshadow primary brain neoplasms in frequency and are an important complication in the overall management of many cancers. Importantly, advances are being made in understanding the molecular biology underlying the initial development and eventual proliferation of brain metastases. Surgery and radiation remain the cornerstones of the therapy for symptomatic lesions; however, image-based guidance is improving surgical technique to maximize the preservation of normal tissue, while more sophisticated approaches to radiation therapy are being used to minimize the long-standing concerns over the toxicity of whole-brain radiation protocols used in the past. Furthermore, the burgeoning knowledge of tumour biology has facilitated the entry of systemically administered therapies into the clinic. Responses to these targeted interventions have ranged from substantial toxicity with no control of disease to periods of useful tumour control with no decrement in performance status of the treated individual. This experience enables recognition of the limits of targeted therapy, but has also informed methods to optimize this approach. This Review focuses on the clinically relevant molecular biology of brain metastases, and summarizes the current applications of these data to imaging, surgery, radiation therapy, cytotoxic chemotherapy and targeted therapy. PMID:24569448
Development of light ion therapy at the Karolinska Hospital and Institute.
Svensson, Hans; Ringborg, Ulrik; Näslund, Ingemar; Brahme, Anders
2004-12-01
Recent developments in radiation therapy have made it possible to optimize the high dose region to cover almost any target volume and shape at the same time as the dose level to adjacent organs at risk is acceptable. Further implementations of IMRT (Intensity Modulated Radiation Therapy), and inverse treatment planning using already available technologies but also foreseeable improved design of therapy accelerators delivering electron- and photon beams, will bring these advances to the benefit of a broad population of cancer patients. Protons will therefore generally not be needed since in most situations the improvement will be insignificant or moderate due to the large lateral penumbra with deep proton therapy. A further step would be to use He-ions, which have only half the penumbra width of protons and still a fairly low-LET in the spread-out Bragg peak. There is however still a group of patients that cannot be helped by these advances as the tumor might be radioresistant for the presently utilized low ionization density beam qualities. The ultimate step in the therapy development process should therefore be to optimize the beam quality for each tumor-normal tissue situation. To facilitate beam quality optimization light ions are needed. It is argued that in many radioresistant tumors a dose-mean LET of 25-50 eV/nm in the target would be optimum as then tumor cells will be lost in the highest proportion through apoptotic cell kill and the superficial tissues will still be irradiated with a fairly low LET. Light ions using Li, Be, B, and C would then be the ideal choice. In this paper a light ion facility is outlined for the Karolinska University Hospital facilitating both dose distribution and beam quality optimization.
Neoadjuvant radiotherapeutic strategies in pancreatic cancer
Roeder, Falk
2016-01-01
This review summarizes the current status of neoadjuvant radiation approaches in the treatment of pancreatic cancer, including a description of modern radiation techniques, and an overview on the literature regarding neoadjuvant radio- or radiochemotherapeutic strategies both for resectable and irresectable pancreatic cancer. Neoadjuvant chemoradiation for locally-advanced, primarily non- or borderline resectable pancreas cancer results in secondary resectability in a substantial proportion of patients with consecutively markedly improved overall prognosis and should be considered as possible alternative in pretreatment multidisciplinary evaluations. In resectable pancreatic cancer, outstanding results in terms of response, local control and overall survival have been observed with neoadjuvant radio- or radiochemotherapy in several phase I/II trials, which justify further evaluation of this strategy. Further investigation of neoadjuvant chemoradiation strategies should be performed preferentially in randomized trials in order to improve comparability of the current results with other treatment modalities. This should include the evaluation of optimal sequencing with newer and more potent systemic induction therapy approaches. Advances in patient selection based on new molecular markers might be of crucial interest in this context. Finally modern external beam radiation techniques (intensity-modulated radiation therapy, image-guided radiation therapy and stereotactic body radiation therapy), new radiation qualities (protons, heavy ions) or combinations with alternative boosting techniques widen the therapeutic window and contribute to the reduction of toxicity. PMID:26909133
Rossi, F; Sabattini, S; Vascellari, M; Marconato, L
2018-05-27
In dogs, inflammatory mammary carcinoma is a clinicopathological entity characterized by rapid progression and aggressive behavior from onset of disease. Reported median survival time is short, with no effective treatment options. The aims of this prospective, noncontrolled clinical trial were to investigate outcome variables and safety profile of toceranib, thalidomide and piroxicam with or without hypofractionated radiation therapy in dogs with measurable histologically confirmed inflammatory mammary carcinoma that underwent a complete staging. Eighteen dogs were enrolled: 14 received medical treatment, and 4 were treated with hypofractionated radiation therapy and medical therapy. Overall, median time to progression was 34 days and median survival time was 109 days. In dogs treated with medical therapy, overall response rate was 21%, and clinical benefit rate (CBR) was 64%; median time to progression was 28 days and median survival time was 59 days. In dogs receiving medical therapy and undergoing radiation therapy, overall response rate and clinical benefit rate were 100%, with significantly longer time to progression (156 days) and survival time (180 days). Overall, treatment was well tolerated, with mild gastrointestinal and dermatological adverse events. Although the optimal treatment to this disease remains uncertain, the current approach consisting of systemic anti-angiogenic drugs with or without hypofractionated radiation therapy, provided clinical benefit in a significant proportion of dogs and should, therefore, be further explored. © 2018 John Wiley & Sons Ltd.
Dosimetric investigation of proton therapy on CT-based patient data using Monte Carlo simulation
NASA Astrophysics Data System (ADS)
Chongsan, T.; Liamsuwan, T.; Tangboonduangjit, P.
2016-03-01
The aim of radiotherapy is to deliver high radiation dose to the tumor with low radiation dose to healthy tissues. Protons have Bragg peaks that give high radiation dose to the tumor but low exit dose or dose tail. Therefore, proton therapy is promising for treating deep- seated tumors and tumors locating close to organs at risk. Moreover, the physical characteristic of protons is suitable for treating cancer in pediatric patients. This work developed a computational platform for calculating proton dose distribution using the Monte Carlo (MC) technique and patient's anatomical data. The studied case is a pediatric patient with a primary brain tumor. PHITS will be used for MC simulation. Therefore, patient-specific CT-DICOM files were converted to the PHITS input. A MATLAB optimization program was developed to create a beam delivery control file for this study. The optimization program requires the proton beam data. All these data were calculated in this work using analytical formulas and the calculation accuracy was tested, before the beam delivery control file is used for MC simulation. This study will be useful for researchers aiming to investigate proton dose distribution in patients but do not have access to proton therapy machines.
How do I deal with the axilla in patients with a positive sentinel lymph node?
Falkson, Conrad B
2011-12-01
Optimal management of the axilla in a patient with a positive sentinel node biopsy is not yet defined.These patients usually have Breast Conserving Surgery and receive adjuvant systemic therapy and whole breast radiation.Treatment options for the axilla include: no further surgery with or without radiation completion axillary nodal dissection with or without radiation Radiation options in addition to whole breast radiation include axillary and supraclavicular nodal irradiation regional nodal irradiationincludes supraclavicular and internal mammary nodes Completion axillary dissection has been standard practice in patients with positive sentinel nodes. the number of involved nodes provides prognostic information. theoretically improves local control, but may be obviated by systemic chemotherapy. but avoidance of dissection may not adversely affect locoregional control or survival. dissection has significant morbidity so safe avoidance is desirable. There is little worldwide concordance on the use of radiation: whole breast radiation (commonly used after breast conserving surgery) may radiate the lower axilla supraclavicular radiation is most commonly recommended for patients with four or more nodes but may confer a survival benefit on patients with lower risk disease. adding nodal irradiation reduces local recurrence with only modest toxicity. Adjuvant systemic therapy provides a survival benefit for patients with nodal disease. Most will receive cytostatic chemotherapy containing an anthracycline and a taxane. Hormone therapy is appropriate for estrogen receptor positive disease. The extent to which systemic therapy controls microscopic nodal disease is unknown. Node positive patients should generally receive adjuvant chemotherapy.A small group of patients benefit from specific nodal therapy. Further studies are needed to better identify these patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benaduce, Ana Paula; Brenneman, Randall; Schrand, Brett
Purpose: To report a novel strategy using oligonucleotide aptamers to 4-1BB as an alternate method for costimulation, and show that combinatorial therapy with radiation improves the therapeutic ratio over equivalent monoclonal antibodies. Methods and Materials: Subcutaneous 4T1 (mouse mammary carcinoma) tumors were established (approximately 100 mm{sup 3}), and a radiation therapy (RT) dose/fractionation schedule that optimally synergizes with 4-1BB monoclonal antibody (mAb) was identified. Comparable tumor control and animal survival was observed when either 4-1BB antibody or aptamer were combined with RT using models of breast cancer and melanoma (4T1 and B16-F10). Off-target CD8{sup +} T-cell toxicity was evaluated by quantification ofmore » CD8{sup +} T cells in livers and spleens of treated animals. Results: When combined with 4-1BB mAb, significant differences in tumor control were observed by varying RT dose and fractionation schedules. Optimal synergy between RT and 4-1BB mAb was observed at 5 Gy × 6. Testing 4-1BB mAb and aptamer independently using the optimal RT (5 Gy × 6 for 4T1/Balb/c and 12 Gy × 1 for B16/C57BL6J mouse models) revealed equivalent tumor control using 4-1BB aptamer and 4-1BB mAb. 4-1BB mAb, but not 4-1BB aptamer-treated animals, exhibited increased lymphocytic liver infiltrates and increased splenic and liver CD8{sup +} T cells. Conclusions: Radiation therapy synergizes with 4-1BB mAb, and this effect is dependent on RT dose and fractionation. Tumor control by 4-1BB aptamer is equivalent to 4-1BB mAb when combined with optimal RT dose, without eliciting off-target liver and spleen CD8{sup +} expansion. 4-1BB aptamer-based costimulation affords a comparable and less toxic strategy to augment RT-mediated tumor control.« less
Radiation Therapy for Pilocytic Astrocytomas of Childhood
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mansur, David B., E-mail: mansur@radonc.wustl.ed; Rubin, Joshua B.; Kidd, Elizabeth A.
Purpose: Though radiation therapy is generally considered the most effective treatment for unresectable pilocytic astrocytomas in children, there are few data to support this claim. To examine the efficacy of radiation therapy for pediatric pilocytic astrocytomas, we retrospectively reviewed the experience at our institution. Methods and Materials: Thirty-five patients 18 years old or younger with unresectable tumors and without evidence of neurofibromatosis have been treated since 1982. Patients were treated with local radiation fields to a median dose of 54 Gy. Six patients were treated with radiosurgery to a median dose of 15.5 Gy. Five patients were treated with initialmore » chemotherapy and irradiated after progression. Results: All patients were alive after a median follow-up of 5.0 years. However, progression-free survival was 68.7%. None of 11 infratentorial tumors progressed compared with 6 of 20 supratentorial tumors. A trend toward improved progression-free survival was seen with radiosurgery (80%) compared with external beam alone (66%), but this difference did not reach statistical significance. Eight of the 9 patients progressing after therapy did so within the irradiated volume. Conclusions: Although the survival of these children is excellent, almost one third of patients have progressive disease after definitive radiotherapy. Improvements in tumor control are needed in this patient population, and the optimal therapy has not been fully defined. Prospective trials comparing initial chemotherapy to radiation therapy are warranted.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wada, Satoshi; Harris, Timothy J.; Tryggestad, Erik
2013-11-15
Purpose: To optimize the combination of ionizing radiation and cellular immunotherapy using a preclinical autochthonous model of prostate cancer. Methods and Materials: Transgenic mice expressing a model antigen under a prostate-specific promoter were treated using a platform that integrates cone-beam CT imaging with 3-dimensional conformal therapy. Using this technology we investigated the immunologic and therapeutic effects of combining ionizing radiation with granulocyte/macrophage colony-stimulating factor-secreting cellular immunotherapy for prostate cancer in mice bearing autochthonous prostate tumors. Results: The combination of ionizing radiation and immunotherapy resulted in a significant decrease in pathologic tumor grade and gross tumor bulk that was not evidentmore » with either single-modality therapy. Furthermore, combinatorial therapy resulted in improved overall survival in a preventive metastasis model and in the setting of established micrometastases. Mechanistically, combined therapy resulted in an increase of the ratio of effector-to-regulatory T cells for both CD4 and CD8 tumor-infiltrating lymphocytes. Conclusions: Our preclinical model establishes a potential role for the use of combined radiation-immunotherapy in locally advanced prostate cancer, which warrants further exploration in a clinical setting.« less
[Doses to organs at risk in conformational radiotherapy and stereotaxic irradiation: The heart].
Vandendorpe, B; Servagi Vernat, S; Ramiandrisoa, F; Bazire, L; Kirova, Y M
2017-10-01
Radiation therapy of breast cancer, Hodgkin lymphoma, lung cancer and others thoracic irradiations induce an ionizing radiation dose to the heart. Irradiation of the heart, associated with patient cardiovascular risk and cancer treatment-induced cardiotoxicity, increase cardiovascular mortality. The long survival after breast or Hodgkin lymphoma irradiation requires watching carefully late treatment toxicity. The over-risk of cardiac events is related to the dose received by the heart and the irradiated cardiac volume. The limitation of cardiac irradiation should be a priority in the planning of thoracic irradiations. Practices have to be modified, using modern techniques to approach of the primary objective of radiotherapy which is to optimize the dose to the target volume, sparing healthy tissues, in this case the heart. We have reviewed the literature on cardiac toxicity induced by conformational tridimensional radiation therapy, intensity-modulated radiation therapy or stereotactic body radiation therapy, in order to evaluate the possibilities to limit cardiotoxicity. Finally, we summarise the recommendations on dose constraints to the heart and coronary arteries. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
Radiation Toxicity to the Cardiovascular System.
Marmagkiolis, Konstantinos; Finch, William; Tsitlakidou, Despina; Josephs, Tyler; Iliescu, Cezar; Best, John F; Yang, Eric H
2016-03-01
Radiation therapy is an important component of cancer treatment, and today, it is applied to approximately 50% of malignancies, including valvular, myocardial, pericardial, coronary or peripheral vascular disease, and arrhythmias. An increased clinical suspicion and knowledge of those mechanisms is important to initiate appropriate screening for the optimal diagnosis and treatment. As the number of cancer survivors has been steadily increasing over the last decades, cardio-oncology, an evolving subspecialty of cardiology, will soon play a pivotal role in raising awareness of the increased cardiovascular risk and formulate strategies to optimally manage patients in this unique population.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Redmond, Kristin J., E-mail: kjanson3@jhmi.edu; Lo, Simon S.; Fisher, Charles
Postoperative stereotactic body radiation therapy (SBRT) for metastatic spinal tumors is increasingly being performed in clinical practice. Whereas the fundamentals of SBRT practice for intact spinal metastases are established, there are as yet no comprehensive practice guidelines for the postoperative indications. In particular, there are unique considerations for patient selection and treatment planning specific to postoperative spine SBRT that are critical for safe and effective management. The purpose of this critical review is to discuss the rationale for treatment, describe those factors affecting surgical decision making, introduce modern surgical trends, and summarize treatment outcomes for both conventional postoperative external beammore » radiation therapy and postoperative spine SBRT. Lastly, an in-depth practical discussion with respect to treatment planning and delivery considerations is provided to help guide optimal practice.« less
General strategy for the protection of organs at risk in IMRT therapy of a moving body
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abolfath, Ramin M.; Papiez, Lech
2009-07-15
We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it possible to search for global minima in a complex landscape of multiple irradiation strategies delivering a given, predetermined intensity map to a target. The optimal strategy was investigated with respect to minimizing the dose delivered to the OAR. The optimization procedure developed relies on variability of all parameters available for control ofmore » radiation delivery in modern linear accelerators, including adaptation of leaf trajectories and simultaneous modification of beam dose rate during irradiation. We showed that the optimization algorithms lead to a significant reduction in the dose delivered to OAR in cases where organs at risk move relative to a treatment target.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fredriksson, Albin, E-mail: albin.fredriksson@raysearchlabs.com; Hårdemark, Björn; Forsgren, Anders
2015-07-15
Purpose: This paper introduces a method that maximizes the probability of satisfying the clinical goals in intensity-modulated radiation therapy treatments subject to setup uncertainty. Methods: The authors perform robust optimization in which the clinical goals are constrained to be satisfied whenever the setup error falls within an uncertainty set. The shape of the uncertainty set is included as a variable in the optimization. The goal of the optimization is to modify the shape of the uncertainty set in order to maximize the probability that the setup error will fall within the modified set. Because the constraints enforce the clinical goalsmore » to be satisfied under all setup errors within the uncertainty set, this is equivalent to maximizing the probability of satisfying the clinical goals. This type of robust optimization is studied with respect to photon and proton therapy applied to a prostate case and compared to robust optimization using an a priori defined uncertainty set. Results: Slight reductions of the uncertainty sets resulted in plans that satisfied a larger number of clinical goals than optimization with respect to a priori defined uncertainty sets, both within the reduced uncertainty sets and within the a priori, nonreduced, uncertainty sets. For the prostate case, the plans taking reduced uncertainty sets into account satisfied 1.4 (photons) and 1.5 (protons) times as many clinical goals over the scenarios as the method taking a priori uncertainty sets into account. Conclusions: Reducing the uncertainty sets enabled the optimization to find better solutions with respect to the errors within the reduced as well as the nonreduced uncertainty sets and thereby achieve higher probability of satisfying the clinical goals. This shows that asking for a little less in the optimization sometimes leads to better overall plan quality.« less
Optimal location of radiation therapy centers with respect to geographic access.
Santibáñez, Pablo; Gaudet, Marc; French, John; Liu, Emma; Tyldesley, Scott
2014-07-15
To develop a framework with which to evaluate locations of radiation therapy (RT) centers in a region based on geographic access. Patient records were obtained for all external beam radiation therapy started in 2011 for the province of British Columbia, Canada. Two metrics of geographic access were defined. The primary analysis was percentage of patients (coverage) within a 90-minute drive from an RT center (C90), and the secondary analysis was the average drive time (ADT) to an RT center. An integer programming model was developed to determine optimal center locations, catchment areas, and capacity required under different scenarios. Records consisted of 11,096 courses of radiation corresponding to 161,616 fractions. Baseline geographic access was estimated at 102.5 minutes ADT (each way, per fraction) and 75.9% C90. Adding 2 and 3 new centers increased C90 to 88% and 92%, respectively, and decreased ADT by between 43% and 61%, respectively. A scenario in which RT was provided in every potential location that could support at least 1 fully utilized linear accelerator resulted in 35.3 minutes' ADT and 93.6% C90. The proposed framework and model provide a data-driven means to quantitatively evaluate alternative configurations of a regional RT system. Results suggest that the choice of location for future centers can significantly improve geographic access to RT. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Palliative radiation therapy for bone metastases: Update of an ASTRO Evidence-Based Guideline.
Lutz, Stephen; Balboni, Tracy; Jones, Joshua; Lo, Simon; Petit, Joshua; Rich, Shayna E; Wong, Rebecca; Hahn, Carol
The purpose is to provide an update the Bone Metastases Guideline published in 2011 based on evidence complemented by expert opinion. The update will discuss new high-quality literature for the 8 key questions from the original guideline and implications for practice. A systematic PubMed search from the last date included in the original Guideline yielded 414 relevant articles. Ultimately, 20 randomized controlled trials, 32 prospective nonrandomized studies, and 4 meta-analyses/pooled analyses were selected and abstracted into evidence tables. The authors synthesized the evidence and reached consensus on the included recommendations. Available literature continues to support pain relief equivalency between single and multiple fraction regimens for bone metastases. High-quality data confirm single fraction radiation therapy may be delivered to spine lesions with acceptable late toxicity. One prospective, randomized trial confirms both peripheral and spine-based painful metastases can be successfully and safely palliated with retreatment for recurrence pain with adherence to published dosing constraints. Advanced radiation therapy techniques such as stereotactic body radiation therapy lack high-quality data, leading the panel to favor its use on a clinical trial or when results will be collected in a registry. The panel's conclusion remains that surgery, radionuclides, bisphosphonates, and kyphoplasty/vertebroplasty do not obviate the need for external beam radiation therapy. Updated data analysis confirms that radiation therapy provides excellent palliation for painful bone metastases and that retreatment is safe and effective. Although adherence to evidence-based medicine is critical, thorough expert radiation oncology physician judgment and discretion regarding number of fractions and advanced techniques are also essential to optimize outcomes when considering the patient's overall health, life expectancy, comorbidities, tumor biology, anatomy, previous treatment including prior radiation at or near current site of treatment, tumor and normal tissue response history to local and systemic therapies, and other factors related to the patient, tumor characteristics, or treatment. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, X; Belcher, AH; Wiersma, R
Purpose: In radiation therapy optimization the constraints can be either hard constraints which must be satisfied or soft constraints which are included but do not need to be satisfied exactly. Currently the voxel dose constraints are viewed as soft constraints and included as a part of the objective function and approximated as an unconstrained problem. However in some treatment planning cases the constraints should be specified as hard constraints and solved by constrained optimization. The goal of this work is to present a computation efficiency graph form alternating direction method of multipliers (ADMM) algorithm for constrained quadratic treatment planning optimizationmore » and compare it with several commonly used algorithms/toolbox. Method: ADMM can be viewed as an attempt to blend the benefits of dual decomposition and augmented Lagrangian methods for constrained optimization. Various proximal operators were first constructed as applicable to quadratic IMRT constrained optimization and the problem was formulated in a graph form of ADMM. A pre-iteration operation for the projection of a point to a graph was also proposed to further accelerate the computation. Result: The graph form ADMM algorithm was tested by the Common Optimization for Radiation Therapy (CORT) dataset including TG119, prostate, liver, and head & neck cases. Both unconstrained and constrained optimization problems were formulated for comparison purposes. All optimizations were solved by LBFGS, IPOPT, Matlab built-in toolbox, CVX (implementing SeDuMi) and Mosek solvers. For unconstrained optimization, it was found that LBFGS performs the best, and it was 3–5 times faster than graph form ADMM. However, for constrained optimization, graph form ADMM was 8 – 100 times faster than the other solvers. Conclusion: A graph form ADMM can be applied to constrained quadratic IMRT optimization. It is more computationally efficient than several other commercial and noncommercial optimizers and it also used significantly less computer memory.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zarepisheh, M; Li, R; Xing, L
Purpose: Station Parameter Optimized Radiation Therapy (SPORT) was recently proposed to fully utilize the technical capability of emerging digital LINACs, in which the station parameters of a delivery system, (such as aperture shape and weight, couch position/angle, gantry/collimator angle) are optimized altogether. SPORT promises to deliver unprecedented radiation dose distributions efficiently, yet there does not exist any optimization algorithm to implement it. The purpose of this work is to propose an optimization algorithm to simultaneously optimize the beam sampling and aperture shapes. Methods: We build a mathematical model whose variables are beam angles (including non-coplanar and/or even nonisocentric beams) andmore » aperture shapes. To solve the resulting large scale optimization problem, we devise an exact, convergent and fast optimization algorithm by integrating three advanced optimization techniques named column generation, gradient method, and pattern search. Column generation is used to find a good set of aperture shapes as an initial solution by adding apertures sequentially. Then we apply the gradient method to iteratively improve the current solution by reshaping the aperture shapes and updating the beam angles toward the gradient. Algorithm continues by pattern search method to explore the part of the search space that cannot be reached by the gradient method. Results: The proposed technique is applied to a series of patient cases and significantly improves the plan quality. In a head-and-neck case, for example, the left parotid gland mean-dose, brainstem max-dose, spinal cord max-dose, and mandible mean-dose are reduced by 10%, 7%, 24% and 12% respectively, compared to the conventional VMAT plan while maintaining the same PTV coverage. Conclusion: Combined use of column generation, gradient search and pattern search algorithms provide an effective way to optimize simultaneously the large collection of station parameters and significantly improves quality of resultant treatment plans as compared with conventional VMAT or IMRT treatments.« less
Zieminski, Stephen; Khandekar, Melin; Wang, Yi
2018-03-01
This study compared the dosimetric performance of (a) volumetric modulated arc therapy (VMAT) with standard optimization (STD) and (b) multi-criteria optimization (MCO) to (c) intensity modulated radiation therapy (IMRT) with MCO for hippocampal avoidance whole brain radiation therapy (HA-WBRT) in RayStation treatment planning system (TPS). Ten HA-WBRT patients previously treated with MCO-IMRT or MCO-VMAT on an Elekta Infinity accelerator with Agility multileaf collimators (5-mm leaves) were re-planned for the other two modalities. All patients received 30 Gy in 15 fractions to the planning target volume (PTV), namely, PTV30 expanded with a 2-mm margin from the whole brain excluding hippocampus with margin. The patients all had metastatic lesions (up to 12) of variable sizes and proximity to the hippocampus, treated with an additional 7.5 Gy from a simultaneous integrated boost (SIB) to PTV37.5. The IMRT plans used eight to eleven non-coplanar fields, whereas the VMAT plans used two coplanar full arcs and a vertex half arc. The averaged target coverage, dose to organs-at-risk (OARs) and monitor unit provided by the three modalities were compared, and a Wilcoxon signed-rank test was performed. MCO-VMAT provided statistically significant reduction of D100 of hippocampus compared to STD-VMAT, and Dmax of cochleas compared to MCO-IMRT. With statistical significance, MCO-VMAT improved V30 of PTV30 by 14.2% and 4.8%, respectively, compared to MCO-IMRT and STD-VMAT. It also raised D95 of PTV37.5 by 0.4 Gy compared to both MCO-IMRT and STD-VMAT. Improved plan quality parameters such as a decrease in overall plan Dmax and total monitor units (MU) were also observed for MCO-VMAT. MCO-VMAT is found to be the optimal modality for HA-WBRT in terms of PTV coverage, OAR sparing and delivery efficiency, compared to MCO-IMRT or STD-VMAT. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacDonald, R. Lee; Thomas, Christopher G., E-mail: Chris.Thomas@cdha.nshealth.ca; Department of Medical Physics, Nova Scotia Cancer Centre, Queen Elizabeth II Health Sciences Centre, Halifax, Nova Scotia B3H 1V7
2015-05-15
Purpose: To investigate potential improvement in external beam stereotactic radiation therapy plan quality for cranial cases using an optimized dynamic gantry and patient support couch motion trajectory, which could minimize exposure to sensitive healthy tissue. Methods: Anonymized patient anatomy and treatment plans of cranial cancer patients were used to quantify the geometric overlap between planning target volumes and organs-at-risk (OARs) based on their two-dimensional projection from source to a plane at isocenter as a function of gantry and couch angle. Published dose constraints were then used as weighting factors for the OARs to generate a map of couch-gantry coordinate space,more » indicating degree of overlap at each point in space. A couch-gantry collision space was generated by direct measurement on a linear accelerator and couch using an anthropomorphic solid-water phantom. A dynamic, fully customizable algorithm was written to generate a navigable ideal trajectory for the patient specific couch-gantry space. The advanced algorithm can be used to balance the implementation of absolute minimum values of overlap with the clinical practicality of large-scale couch motion and delivery time. Optimized cranial cancer treatment trajectories were compared to conventional treatment trajectories. Results: Comparison of optimized treatment trajectories with conventional treatment trajectories indicated an average decrease in mean dose to the OARs of 19% and an average decrease in maximum dose to the OARs of 12%. Degradation was seen for homogeneity index (6.14% ± 0.67%–5.48% ± 0.76%) and conformation number (0.82 ± 0.02–0.79 ± 0.02), but neither was statistically significant. Removal of OAR constraints from volumetric modulated arc therapy optimization reveals that reduction in dose to OARs is almost exclusively due to the optimized trajectory and not the OAR constraints. Conclusions: The authors’ study indicated that simultaneous couch and gantry motion during radiation therapy to minimize the geometrical overlap in the beams-eye-view of target volumes and the organs-at-risk can have an appreciable dose reduction to organs-at-risk.« less
Montgomery, Logan; Fava, Palma; Freeman, Carolyn R; Hijal, Tarek; Maietta, Ciro; Parker, William; Kildea, John
2018-01-01
Collaborative incident learning initiatives in radiation therapy promise to improve and standardize the quality of care provided by participating institutions. However, the software interfaces provided with such initiatives must accommodate all participants and thus are not optimized for the workflows of individual radiation therapy centers. This article describes the development and implementation of a radiation therapy incident learning system that is optimized for a clinical workflow and uses the taxonomy of the Canadian National System for Incident Reporting - Radiation Treatment (NSIR-RT). The described incident learning system is a novel version of an open-source software called the Safety and Incident Learning System (SaILS). A needs assessment was conducted prior to development to ensure SaILS (a) was intuitive and efficient (b) met changing staff needs and (c) accommodated revisions to NSIR-RT. The core functionality of SaILS includes incident reporting, investigations, tracking, and data visualization. Postlaunch modifications of SaILS were informed by discussion and a survey of radiation therapy staff. There were 240 incidents detected and reported using SaILS in 2016 and the number of incidents per month tended to increase throughout the year. An increase in incident reporting occurred after switching to fully online incident reporting from an initial hybrid paper-electronic system. Incident templating functionality and a connection with our center's oncology information system were incorporated into the investigation interface to minimize repetitive data entry. A taskable actions feature was also incorporated to document outcomes of incident reports and has since been utilized for 36% of reported incidents. Use of SaILS and the NSIR-RT taxonomy has improved the structure of, and staff engagement with, incident learning in our center. Software and workflow modifications informed by staff feedback improved the utility of SaILS and yielded an efficient and transparent solution to categorize incidents with the NSIR-RT taxonomy. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Belard, Arnaud; Dolney, Derek; Zelig, Tochner; McDonough, James; O'Connell, John
2011-06-01
Proton radiotherapy is a relatively scarce treatment modality in radiation oncology, with only nine centers currently operating in the United States. Funded by Public Law 107-248, the University of Pennsylvania and the Walter Reed Army Medical Center have developed a remote proton radiation therapy solution with the goals of improving access to proton radiation therapy for Department of Defense (DoD) beneficiaries while minimizing treatment delays and time spent away from home/work (time savings of up to 3 weeks per patient). To meet both Health Insurance Portability and Accountability Act guidelines and the more stringent security restrictions imposed by the DoD, our program developed a hybrid remote proton radiation therapy solution merging a CITRIX server with a JITIC-certified (Joint Interoperability Test Command) desktop videoconferencing unit. This conduit, thoroughly tested over a period of 6 months, integrates both institutions' radiation oncology treatment planning infrastructures into a single entity for DoD patients' treatment planning and delivery. This telemedicine solution enables DoD radiation oncologists and medical physicists the ability to (1) remotely access a proton therapy treatment planning platform, (2) transfer patient plans securely to the University of Pennsylvania patient database, and (3) initiate ad-hoc point-to-point and multipoint videoconferences to dynamically optimize and validate treatment plans. Our robust and secure remote treatment planning solution grants DoD patients not only access to a state-of-the-art treatment modality, but also participation in the treatment planning process by Walter Reed Army Medical Center radiation oncologists and medical physicists. This telemedicine system has the potential to lead to a greater integration of military treatment facilities and/or satellite clinics into regional proton therapy centers.
Kageji, T; Mizobuchi, Y; Nagahiro, S; Nakagawa, Y; Kumada, H
2014-06-01
The purpose of this study was to clarify the correlation between the radiation dose and histopathological findings in patients with glioblastoma multiforme (GBM) treated with boron neutron capture therapy (BNCT). Histopathological studies were performed on specimens from 8 patients, 3 had undergone salvage surgery and 5 were autopsied. For histopathological cure of GBM at the primary site, the optimal minimal dose to the gross tumor volume (GTV) and the clinical target volume (CTV) were 68Gy(w) and 44Gy(w), respectively. Copyright © 2014. Published by Elsevier Ltd.
Porres, D; Pfister, D; Brehmer, B; Heidenreich, A
2012-09-01
For pT3 prostate cancer with positive resection margins, the importance of postoperative radiation therapy is confirmed by a high level of evidence. However, for the pT2,R1 situation prospective, randomized studies concerning this question are lacking. Despite better local tumor control in the pT2 stage the PSA recurrence rate lies between 25% and 40% and positive margins are an independent factor for recurrence. Retrospective studies suggest a positive effect of adjuvant or salvage radiation for the oncological outcome in the pT2,R1 situation. On the other hand the side effects profile, with a potentially negative influence of postoperative continence and various delayed toxicities, is not insignificant despite modern radiation techniques and in the era of ultrasensitive PSA analysis should be considered in the risk-benefit assessment. As long as the optimal initiation of postoperative radiation therapy is unclear, the assessment of indications for adjuvant or salvage radiation for organ-limited prostate cancer with positive resection margins should be made after an individual patient consultation and under consideration of the recurrence risk factors, such as the Gleason grade and the localization and extent of the resection margins.
Ellis, Thomas L.; Neal, Matthew T.; Chan, Michael D.
2012-01-01
Brain tumors constitute the most common intracranial tumor. Management of brain metastases has become increasingly complex as patients with brain metastases are living longer and more treatment options develop. The goal of this paper is to review the role of stereotactic radiosurgery (SRS), whole brain radiation therapy (WBRT), and surgery, in isolation and in combination, in the contemporary treatment of brain metastases. Surgery and SRS both offer management options that may help to optimize therapy in selected patients. WBRT is another option but can lead to late toxicity and suboptimal local control in longer term survivors. Improved prognostic indices will be critical for selecting the best therapies. Further prospective trials are necessary to continue to elucidate factors that will help triage patients to the proper brain-directed therapy for their cancer. PMID:22312545
NASA Astrophysics Data System (ADS)
Xu, Jun; Papanikolaou, Nikos; Shi, Chengyu; Jiang, Steve B.
2009-08-01
Synchronized moving aperture radiation therapy (SMART) has been proposed to account for tumor motions during radiotherapy in prior work. The basic idea of SMART is to synchronize the moving radiation beam aperture formed by a dynamic multileaf collimator (DMLC) with the tumor motion induced by respiration. In this paper, a two-dimensional (2D) superimposing leaf sequencing method is presented for SMART. A leaf sequence optimization strategy was generated to assure the SMART delivery under realistic delivery conditions. The study of delivery performance using the Varian LINAC and the Millennium DMLC showed that clinical factors such as collimator angle, dose rate, initial phase and machine tolerance affect the delivery accuracy and efficiency. An in-house leaf sequencing software was developed to implement the 2D superimposing leaf sequencing method and optimize the motion-corrected leaf sequence under realistic clinical conditions. The analysis of dynamic log (Dynalog) files showed that optimization of the leaf sequence for various clinical factors can avoid beam hold-offs which break the synchronization of SMART and fail the SMART dose delivery. Through comparison between the simulated delivered fluence map and the planed fluence map, it was shown that the motion-corrected leaf sequence can greatly reduce the dose error.
Xu, Jun; Papanikolaou, Nikos; Shi, Chengyu; Jiang, Steve B
2009-08-21
Synchronized moving aperture radiation therapy (SMART) has been proposed to account for tumor motions during radiotherapy in prior work. The basic idea of SMART is to synchronize the moving radiation beam aperture formed by a dynamic multileaf collimator (DMLC) with the tumor motion induced by respiration. In this paper, a two-dimensional (2D) superimposing leaf sequencing method is presented for SMART. A leaf sequence optimization strategy was generated to assure the SMART delivery under realistic delivery conditions. The study of delivery performance using the Varian LINAC and the Millennium DMLC showed that clinical factors such as collimator angle, dose rate, initial phase and machine tolerance affect the delivery accuracy and efficiency. An in-house leaf sequencing software was developed to implement the 2D superimposing leaf sequencing method and optimize the motion-corrected leaf sequence under realistic clinical conditions. The analysis of dynamic log (Dynalog) files showed that optimization of the leaf sequence for various clinical factors can avoid beam hold-offs which break the synchronization of SMART and fail the SMART dose delivery. Through comparison between the simulated delivered fluence map and the planed fluence map, it was shown that the motion-corrected leaf sequence can greatly reduce the dose error.
Aherne, Noel J; Benjamin, Linus C; Horsley, Patrick J; Silva, Thomaz; Wilcox, Shea; Amalaseelan, Julan; Dwyer, Patrick; Tahir, Abdul M R; Hill, Jacques; Last, Andrew; Hansen, Carmen; McLachlan, Craig S; Lee, Yvonne L; McKay, Michael J; Shakespeare, Thomas P
2014-01-01
Purpose. Glioblastoma multiforme (GBM) is optimally treated by maximal debulking followed by combined chemoradiation. Intensity modulated radiation therapy (IMRT) is gaining widespread acceptance in other tumour sites, although evidence to support its use over three-dimensional conformal radiation therapy (3DCRT) in the treatment of gliomas is currently lacking. We examined the survival outcomes for patients with GBM treated with IMRT and Temozolomide. Methods and Materials. In all, 31 patients with GBM were treated with IMRT and 23 of these received chemoradiation with Temozolomide. We correlated survival outcomes with patient functional status, extent of surgery, radiation dose, and use of chemotherapy. Results. Median survival for all patients was 11.3 months, with a median survival of 7.2 months for patients receiving 40.05 Gray (Gy) and a median survival of 17.4 months for patients receiving 60 Gy. Conclusions. We report one of the few series of IMRT in patients with GBM. In our group, median survival for those receiving 60 Gy with Temozolomide compared favourably to the combined therapy arm of the largest randomised trial of chemoradiation versus radiation to date (17.4 months versus 14.6 months). We propose that IMRT should be considered as an alternative to 3DCRT for patients with GBM.
Aherne, Noel J.; Benjamin, Linus C.; Horsley, Patrick J.; Silva, Thomaz; Wilcox, Shea; Amalaseelan, Julan; Dwyer, Patrick; Tahir, Abdul M. R.; Hill, Jacques; Last, Andrew; Hansen, Carmen; McLachlan, Craig S.; Lee, Yvonne L.; McKay, Michael J.; Shakespeare, Thomas P.
2014-01-01
Purpose. Glioblastoma multiforme (GBM) is optimally treated by maximal debulking followed by combined chemoradiation. Intensity modulated radiation therapy (IMRT) is gaining widespread acceptance in other tumour sites, although evidence to support its use over three-dimensional conformal radiation therapy (3DCRT) in the treatment of gliomas is currently lacking. We examined the survival outcomes for patients with GBM treated with IMRT and Temozolomide. Methods and Materials. In all, 31 patients with GBM were treated with IMRT and 23 of these received chemoradiation with Temozolomide. We correlated survival outcomes with patient functional status, extent of surgery, radiation dose, and use of chemotherapy. Results. Median survival for all patients was 11.3 months, with a median survival of 7.2 months for patients receiving 40.05 Gray (Gy) and a median survival of 17.4 months for patients receiving 60 Gy. Conclusions. We report one of the few series of IMRT in patients with GBM. In our group, median survival for those receiving 60 Gy with Temozolomide compared favourably to the combined therapy arm of the largest randomised trial of chemoradiation versus radiation to date (17.4 months versus 14.6 months). We propose that IMRT should be considered as an alternative to 3DCRT for patients with GBM. PMID:24563782
Optimal Location of Radiation Therapy Centers With Respect to Geographic Access
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santibáñez, Pablo; Gaudet, Marc; French, John
2014-07-15
Purpose: To develop a framework with which to evaluate locations of radiation therapy (RT) centers in a region based on geographic access. Methods and Materials: Patient records were obtained for all external beam radiation therapy started in 2011 for the province of British Columbia, Canada. Two metrics of geographic access were defined. The primary analysis was percentage of patients (coverage) within a 90-minute drive from an RT center (C90), and the secondary analysis was the average drive time (ADT) to an RT center. An integer programming model was developed to determine optimal center locations, catchment areas, and capacity required undermore » different scenarios. Results: Records consisted of 11,096 courses of radiation corresponding to 161,616 fractions. Baseline geographic access was estimated at 102.5 minutes ADT (each way, per fraction) and 75.9% C90. Adding 2 and 3 new centers increased C90 to 88% and 92%, respectively, and decreased ADT by between 43% and 61%, respectively. A scenario in which RT was provided in every potential location that could support at least 1 fully utilized linear accelerator resulted in 35.3 minutes' ADT and 93.6% C90. Conclusions: The proposed framework and model provide a data-driven means to quantitatively evaluate alternative configurations of a regional RT system. Results suggest that the choice of location for future centers can significantly improve geographic access to RT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shah, Chirag; Vicini, Frank A., E-mail: fvicini@beaumont.edu
As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer-related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially withmore » a range of 2-65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leinders, Suzanne M.; Delft University of Technology, Delft; Breedveld, Sebastiaan
Purpose: To investigate how dose distributions for liver stereotactic body radiation therapy (SBRT) can be improved by using automated, daily plan reoptimization to account for anatomy deformations, compared with setup corrections only. Methods and Materials: For 12 tumors, 3 strategies for dose delivery were simulated. In the first strategy, computed tomography scans made before each treatment fraction were used only for patient repositioning before dose delivery for correction of detected tumor setup errors. In adaptive second and third strategies, in addition to the isocenter shift, intensity modulated radiation therapy beam profiles were reoptimized or both intensity profiles and beam orientationsmore » were reoptimized, respectively. All optimizations were performed with a recently published algorithm for automated, multicriteria optimization of both beam profiles and beam angles. Results: In 6 of 12 cases, violations of organs at risk (ie, heart, stomach, kidney) constraints of 1 to 6 Gy in single fractions occurred in cases of tumor repositioning only. By using the adaptive strategies, these could be avoided (<1 Gy). For 1 case, this needed adaptation by slightly underdosing the planning target volume. For 2 cases with restricted tumor dose in the planning phase to avoid organ-at-risk constraint violations, fraction doses could be increased by 1 and 2 Gy because of more favorable anatomy. Daily reoptimization of both beam profiles and beam angles (third strategy) performed slightly better than reoptimization of profiles only, but the latter required only a few minutes of computation time, whereas full reoptimization took several hours. Conclusions: This simulation study demonstrated that replanning based on daily acquired computed tomography scans can improve liver stereotactic body radiation therapy dose delivery.« less
Quant, Eudocia C; Wen, Patrick Y
2010-08-01
The prognosis for glioblastoma is poor despite optimal therapy with surgery, radiation, and chemotherapy. New therapies that improve survival and quality of life are needed. Research has increased our understanding of the molecular pathways important for gliomagenesis and disease progression. Novel agents have been developed against these targets, including receptor tyrosine kinases, intracellular signaling molecules, epigenetic abnormalities, and tumor vasculature and microenvironment. This article reviews novel therapies for glioblastoma, with an emphasis on targeted agents. Copyright 2010 Elsevier Inc. All rights reserved.
Hypofractionated radiation therapy for prostate cancer: biologic and technical considerations
Sanfilippo, Nicholas J; Cooper, Benjamin T
2014-01-01
The optimal radiation schedule for the curative treatment of prostate cancer is not known. The dose-response of tumors and normal tissues to fractionated irradiation can be described according to a parameter called the alpha-beta ratio (α/β). In the past several years numerous reports have been published that suggest that the alpha-beta ratio for prostate cancer may be quite low; between 1 and 3. If this hypothesis is true, then a radiation therapy schedule that employs less frequent and larger fractions, termed hypofractionation, may be more efficacious. Multiple randomized trials have been conducted comparing moderate (less than 5 Gy/day) hypofractionated radiation therapy and standard radiation therapy in men with prostate cancer. In the majority of these studies the moderate hypofractionated arm had equivalent efficacy with a similar or improved side effect profile. One area to use caution may be in patients with compromised (IPSS > 12) urinary function at baseline due to an increase in urinary toxicity observed in patients treated with hypofractionated radiation in one study. Extreme hypofractionation (greater than or equal to 5 Gy/day), is currently being compared in a randomized trial. Early prospectively collected data from multiple institutions demonstrates efficacy and toxicity that compares favorably with historical controls. The cost savings from hypofractionation could be profound on a national level and only increases the necessity of testing hypofractionated treatment schedules. Long term data and future trials will help radiation oncologists determine the ideal fractionation scheme based on cost, efficacy, and toxicity. PMID:25606574
Wortmann, Birgit; Knorr, Jürgen
2012-08-01
In 2001 and 2003, at the University of Pavia, Italy, boron neutron capture therapy (BNCT) has been successfully used in the treatment of hepatic colorectal metastases (Pinelli et al., 2002; Zonta et al., 2006). The treatment procedure (TAOrMINA protocol) is characterised by the auto-transplantation and extracorporeal irradiation of the liver using a thermal neutron beam. The clinical use of this approach requires well founded data and an optimized irradiation facility. In order to start with this work and to decide upon its feasibility at the research reactor TRIGA Mainz, basic data and requirements have been considered (Wortmann, 2008). Computer calculations using the ATTILA (Transpire Inc. 2006) and MCNP (LANL, 2005) codes have been performed, including data from conventional radiation therapy, from the TAOrMINA approach, resulting in reasonable estimations. Basic data and requirements and optimal parameters have been worked out, especially for use at an optimized TRIGA irradiation facility (Wortmann, 2008). Advantages of the extracorporeal irradiation with auto-transplantation and the potential of an optimized irradiation facility could be identified. Within the requirements, turning the explanted organ over by 180° appears preferable to a whole side source, similar to a permanent rotation of the organ. The design study and the parameter optimization confirm the potential of this approach to treat metastases in explanted organs. The results do not represent actual treatment data but a first estimation. Although all specific values refer to the TRIGA Mainz, they may act as a useful guide for other types of neutron sources. The recommended modifications (Wortmann, 2008) show the suitability of TRIGA reactors as a radiation source for BNCT of extracorporeal irradiated and auto-transplanted organs. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Xiao, Ying; Michalski, Darek; Censor, Yair; Galvin, James M.
2004-07-01
The efficient delivery of intensity modulated radiation therapy (IMRT) depends on finding optimized beam intensity patterns that produce dose distributions, which meet given constraints for the tumour as well as any critical organs to be spared. Many optimization algorithms that are used for beamlet-based inverse planning are susceptible to large variations of neighbouring intensities. Accurately delivering an intensity pattern with a large number of extrema can prove impossible given the mechanical limitations of standard multileaf collimator (MLC) delivery systems. In this study, we apply Cimmino's simultaneous projection algorithm to the beamlet-based inverse planning problem, modelled mathematically as a system of linear inequalities. We show that using this method allows us to arrive at a smoother intensity pattern. Including nonlinear terms in the simultaneous projection algorithm to deal with dose-volume histogram (DVH) constraints does not compromise this property from our experimental observation. The smoothness properties are compared with those from other optimization algorithms which include simulated annealing and the gradient descent method. The simultaneous property of these algorithms is ideally suited to parallel computing technologies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, Jen-San, E-mail: jen-san.tsai@verizon.net; Micaily, Bizhan; Miyamoto, Curtis
2012-10-01
To develop a quality assurance (QA) of XVI cone beam system (XVIcbs) for its optimal imaging-guided radiotherapy (IGRT) implementation, and to construe prostate tumor margin required for intensity-modulated radiation therapy (IMRT) if IGRT is unavailable. XVIcbs spatial accuracy was explored with a humanoid phantom; isodose conformity to lesion target with a rice phantom housing a soap as target; image resolution with a diagnostic phantom; and exposure validation with a Radcal ion chamber. To optimize XVIcbs, rotation flexmap on coincidency between gantry rotational axis and that of XVI cone beam scan was investigated. Theoretic correlation to image quality of XVIcbs rotationalmore » axis stability was elaborately studied. Comprehensive QA of IGRT using XVIcbs has initially been explored and then implemented on our general IMRT treatments, and on special IMRT radiotherapies such as head and neck (H and N), stereotactic radiation therapy (SRT), stereotactic radiosurgery (SRS), and stereotactic body radiotherapy (SBRT). Fifteen examples of prostate setup accounted for 350 IGRT cone beam system were analyzed. IGRT accuracy results were in agreement {+-} 1 mm. Flexmap 0.25 mm met the manufacturer's specification. Films confirmed isodose coincidence with target (soap) via XVIcbs, otherwise not. Superficial doses were measured from 7.2-2.5 cGy for anatomic diameters 15-33 cm, respectively. Image quality was susceptible to rotational stability or patient movement. IGRT using XVIcbs on general IMRT treatments such as prostate, SRT, SRS, and SBRT for setup accuracy were verified; and subsequently coordinate shifts corrections were recorded. The 350 prostate IGRT coordinate shifts modeled to Gaussian distributions show central peaks deviated off the isocenter by 0.6 {+-} 3.0 mm, 0.5 {+-} 4.5 mm in the X(RL)- and Z(SI)-coordinates, respectively; and 2.0 {+-} 3.0 mm in the Y(AP)-coordinate as a result of belly and bladder capacity variations. Sixty-eight percent of confidence was within {+-} 4.5 mm coordinates shifting. IGRT using XVIcbs is critical to IMRT for prostate and H and N, especially SRT, SRS, and SBRT. To optimize this modality of IGRT, a vigilant QA program is indispensable. Prostate IGRT reveals treatment accuracy as subject to coordinates' adjustments; otherwise a 4.5-mm margin is required to allow for full dose coverage of the clinical target volume, notwithstanding toxicity to normal tissues.« less
Chen, Bert T; Wood, David P
2003-12-29
Asymptomatic prostate-specific antigen (PSA) recurrence after radiation therapy for prostate carcinoma poses a diagnostic and therapeutic dilemma for clinicians. Patients with locally recurrent disease can consider treatment options of salvage surgery, cryotherapy, watchful waiting, or androgen deprivation. Of these options, only salvage surgery has been shown to result in long-term disease-free survival for selected patients. However, salvage surgery is associated with significant morbidity, including urinary incontinence and rectal injuries. Ideally, salvage surgery outcomes can be optimized with careful patient selection according to clinical stage, serum PSA levels before radiation and surgery, the medical condition of the patient, and clear expectations of the physician and patient. Among patients with locally recurrent disease, those with localized prostate carcinoma amenable to radical prostatectomy before radiation or cryotherapy would be the most suitable candidates for salvage surgery.
Fan, Jiawei; Wang, Jiazhou; Zhang, Zhen; Hu, Weigang
2017-06-01
To develop a new automated treatment planning solution for breast and rectal cancer radiotherapy. The automated treatment planning solution developed in this study includes selection of the iterative optimized training dataset, dose volume histogram (DVH) prediction for the organs at risk (OARs), and automatic generation of clinically acceptable treatment plans. The iterative optimized training dataset is selected by an iterative optimization from 40 treatment plans for left-breast and rectal cancer patients who received radiation therapy. A two-dimensional kernel density estimation algorithm (noted as two parameters KDE) which incorporated two predictive features was implemented to produce the predicted DVHs. Finally, 10 additional new left-breast treatment plans are re-planned using the Pinnacle 3 Auto-Planning (AP) module (version 9.10, Philips Medical Systems) with the objective functions derived from the predicted DVH curves. Automatically generated re-optimized treatment plans are compared with the original manually optimized plans. By combining the iterative optimized training dataset methodology and two parameters KDE prediction algorithm, our proposed automated planning strategy improves the accuracy of the DVH prediction. The automatically generated treatment plans using the dose derived from the predicted DVHs can achieve better dose sparing for some OARs without compromising other metrics of plan quality. The proposed new automated treatment planning solution can be used to efficiently evaluate and improve the quality and consistency of the treatment plans for intensity-modulated breast and rectal cancer radiation therapy. © 2017 American Association of Physicists in Medicine.
Accelerated partial breast irradiation: Past, present, and future
Tann, Anne W; Hatch, Sandra S; Joyner, Melissa M; Wiederhold, Lee R; Swanson, Todd A
2016-01-01
Accelerated partial breast irradiation (APBI) focuses higher doses of radiation during a shorter interval to the lumpectomy cavity, in the setting of breast conserving therapy for early stage breast cancer. The utilization of APBI has increased in the past decade because of the shorter treatment schedule and a growing body of outcome data showing positive cosmetic outcomes and high local control rates in selected patients undergoing breast conserving therapy. Technological advances in various APBI modalities, including intracavitary and interstitial brachytherapy, intraoperative radiation therapy, and external beam radiation therapy, have made APBI more accessible in the community. Results of early APBI trials served as the basis for the current consensus guidelines, and multiple prospective randomized clinical trials are currently ongoing. The pending long term results of these trials will help us identify optimal candidates that can benefit from ABPI. Here we provide an overview of the clinical and cosmetic outcomes of various APBI techniques and review the current guidelines for selecting suitable breast cancer patients. We also discuss the impact of APBI on the economics of cancer care and patient reported quality of life. PMID:27777879
Outcomes of Pituitary Radiation for Cushing's Disease.
Ironside, Natasha; Chen, Ching-Jen; Lee, Cheng-Chia; Trifiletti, Daniel M; Vance, Mary Lee; Sheehan, Jason P
2018-06-01
Achievement of biochemical remission with preservation of normal pituitary function is the goal of treatment for Cushing's disease. For patients with persistent or recurrent Cushing's disease after transsphenoidal resection, radiation therapy may be a safe and effective treatment. Stereotactic radiosurgery is favored over conventional fractionated external beam radiation. Hormonal recurrence rates range from 0% to 36% at 8 years after treatment. Tumor control rates are high. New pituitary hormone deficiency is the most common adverse effect after stereotactic radiosurgery and external beam radiation. The effects of radiation planning optimization and use of adjuvant medication on endocrine remission rates warrant investigation. Copyright © 2018 Elsevier Inc. All rights reserved.
Gandhi, Saumil J; Liang, Xing; Ding, Xuanfeng; Zhu, Timothy C; Ben-Josef, Edgar; Plastaras, John P; Metz, James M; Both, Stefan; Apisarnthanarax, Smith
2015-01-01
Stereotactic body radiation therapy (SBRT) for treatment of liver tumors is often limited by liver dose constraints. Protons offer potential for more liver sparing, but clinical situations in which protons may be superior to photons are not well described. We developed and validated a treatment decision model to determine whether liver tumors of certain sizes and locations are more suited for photon versus proton SBRT. Six spherical mock tumors from 1 to 6 cm in diameter were contoured on computed tomography images of 1 patient at 4 locations: dome, caudal, left medial, and central. Photon and proton plans were generated to deliver 50 Gy in 5 fractions to each tumor and optimized to deliver equivalent target coverage and maximal liver sparing. Using these plans, we developed a hypothesis-generating model to predict the optimal modality for maximal liver sparing based on tumor size and location. We then validated this model in 10 patients with liver tumors. Protons spared significantly more liver than photons for dome or central tumors ≥3 cm (dome: 134 ± 21 cm(3), P = .03; central: 108 ± 4 cm(3), P = .01). Our model correctly predicted the optimal SBRT modality for all 10 patients. For patients with dome or central tumors ≥3 cm, protons significantly increased the volume of liver spared (176 ± 21 cm(3), P = .01) and decreased the mean liver dose (8.4 vs 12.2 Gy, P = .01) while offering no significant advantage for tumors <3 cm at any location or for caudal and left medial tumors of any size. When feasible, protons should be considered as the radiation modality of choice for dome and central tumors >3 cm to allow maximal liver sparing and potentially reduce radiation toxicity. Protons should also be considered for any tumor >5 cm if photon plans fail to achieve adequate coverage or exceed the mean liver threshold. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bonacker, Esther; Gibali, Aviv; Küfer, Karl-Heinz; Süss, Philipp
2017-04-01
Multicriteria optimization problems occur in many real life applications, for example in cancer radiotherapy treatment and in particular in intensity modulated radiation therapy (IMRT). In this work we focus on optimization problems with multiple objectives that are ranked according to their importance. We solve these problems numerically by combining lexicographic optimization with our recently proposed level set scheme, which yields a sequence of auxiliary convex feasibility problems; solved here via projection methods. The projection enables us to combine the newly introduced superiorization methodology with multicriteria optimization methods to speed up computation while guaranteeing convergence of the optimization. We demonstrate our scheme with a simple 2D academic example (used in the literature) and also present results from calculations on four real head neck cases in IMRT (Radiation Oncology of the Ludwig-Maximilians University, Munich, Germany) for two different choices of superiorization parameter sets suited to yield fast convergence for each case individually or robust behavior for all four cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grassberger, C; Paganetti, H
Purpose: To develop a model that includes the process of resistance development into the treatment optimization process for schedules that include targeted therapies. Further, to validate the approach using clinical data and to apply the model to assess the optimal induction period with targeted agents before curative treatment with chemo-radiation in stage III lung cancer. Methods: Growth of the tumor and its subpopulations is modeled by Gompertzian growth dynamics, resistance induction as a stochastic process. Chemotherapy induced cell kill is modeled by log-cell kill dynamics, targeted agents similarly but restricted to the sensitive population. Radiation induced cell kill is assumedmore » to follow the linear-quadratic model. The validation patient data consist of a cohort of lung cancer patients treated with tyrosine kinase inhibitors that had longitudinal imaging data available. Results: The resistance induction model was successfully validated using clinical trial data from 49 patients treated with targeted agents. The observed recurrence kinetics, with tumors progressing from 1.4–63 months, result in tumor growth equaling a median volume doubling time of 92 days [34–248] and a median fraction of pre-existing resistance of 0.035 [0–0.22], in agreement with previous clinical studies. The model revealed widely varying optimal time points for the use of curative therapy, reaching from ∼1m to >6m depending on the patient’s growth rate and amount of pre-existing resistance. This demonstrates the importance of patient-specific treatment schedules when targeted agents are incorporated into the treatment. Conclusion: We developed a model including evolutionary dynamics of resistant sub-populations with traditional chemotherapy and radiation cell kill models. Fitting to clinical data yielded patient specific growth rates and resistant fraction in agreement with previous studies. Further application of the model demonstrated how proper timing of chemo-radiation could minimize the probability of resistance, increasing tumor control significantly.« less
NASA Astrophysics Data System (ADS)
Kåver, Gereon; Lind, Bengt K.; Löf, Johan; Liander, Anders; Brahme, Anders
1999-12-01
The aim of the present work is to better account for the known uncertainties in radiobiological response parameters when optimizing radiation therapy. The radiation sensitivity of a specific patient is usually unknown beyond the expectation value and possibly the standard deviation that may be derived from studies on groups of patients. Instead of trying to find the treatment with the highest possible probability of a desirable outcome for a patient of average sensitivity, it is more desirable to maximize the expectation value of the probability for the desirable outcome over the possible range of variation of the radiation sensitivity of the patient. Such a stochastic optimization will also have to consider the distribution function of the radiation sensitivity and the larger steepness of the response for the individual patient. The results of stochastic optimization are also compared with simpler methods such as using biological response `margins' to account for the range of sensitivity variation. By using stochastic optimization, the absolute gain will typically be of the order of a few per cent and the relative improvement compared with non-stochastic optimization is generally less than about 10 per cent. The extent of this gain varies with the level of interpatient variability as well as with the difficulty and complexity of the case studied. Although the dose changes are rather small (<5 Gy) there is a strong desire to make treatment plans more robust, and tolerant of the likely range of variation of the radiation sensitivity of each individual patient. When more accurate predictive assays of the radiation sensitivity for each patient become available, the need to consider the range of variations can be reduced considerably.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlson, D.
The physical pattern of energy deposition and the enhanced relative biological effectiveness (RBE) of protons and carbon ions compared to photons offer unique and not fully understood or exploited opportunities to improve the efficacy of radiation therapy. Variations in RBE within a pristine or spread out Bragg peak and between particle types may be exploited to enhance cell killing in target regions without a corresponding increase in damage to normal tissue structures. In addition, the decreased sensitivity of hypoxic tumors to photon-based therapies may be partially overcome through the use of more densely ionizing radiations. These and other differences betweenmore » particle and photon beams may be used to generate biologically optimized treatments that reduce normal tissue complications. In this symposium, speakers will examine the impact of the RBE of charged particles on measurable biological endpoints, treatment plan optimization, and the prediction or retrospective assessment of treatment outcomes. In particular, an AAPM task group was formed to critically examine the evidence for a spatially-variant RBE in proton therapy. Current knowledge of proton RBE variation with respect to dose, biological endpoint, and physics parameters will be reviewed. Further, the clinical relevance of these variations will be discussed. Recent work focused on improving simulations of radiation physics and biological response in proton and carbon ion therapy will also be presented. Finally, relevant biology research and areas of research needs will be highlighted, including the dependence of RBE on genetic factors including status of DNA repair pathways, the sensitivity of cancer stem-like cells to charged particles, the role of charged particles in hypoxic tumors, and the importance of fractionation effects. In addition to the physical advantages of protons and more massive ions over photons, the future application of biologically optimized treatment plans and their potential to provide higher levels of local tumor control and improved normal tissue sparing will be discussed. Learning Objectives: To assess whether the current practice of a constant RBE of 1.1 should be revised or maintained in proton therapy and to evaluate the potential clinical consequences of delivering RBE-weighted dose distributions based on variable RBE To review current research on biological models used to predict the increased biological effectiveness of proton and carbon ions to help move towards a practical understanding and implementation of biological optimization in particle therapy To discuss potential differences in biological mechanisms between photons and charged particles (light and heavy ions) that could impact clinical cancer therapy H. Paganetti, NCI U19 CA21239D. Grosshans, Our research is supported by the NCIK. Held, Funding Support: National Cancer Institute of the National Institutes of Health, USA, under Award Number R21CA182259 and Federal Share of Program Income Earned by Massachusetts General Hospital on C06CA059267, Proton Therapy Research and Treatment Center.« less
NASA Astrophysics Data System (ADS)
Han, Xiao; Pearson, Erik; Pelizzari, Charles; Al-Hallaq, Hania; Sidky, Emil Y.; Bian, Junguo; Pan, Xiaochuan
2015-06-01
Kilo-voltage (KV) cone-beam computed tomography (CBCT) unit mounted onto a linear accelerator treatment system, often referred to as on-board imager (OBI), plays an increasingly important role in image-guided radiation therapy. While the FDK algorithm is currently used for reconstructing images from clinical OBI data, optimization-based reconstruction has also been investigated for OBI CBCT. An optimization-based reconstruction involves numerous parameters, which can significantly impact reconstruction properties (or utility). The success of an optimization-based reconstruction for a particular class of practical applications thus relies strongly on appropriate selection of parameter values. In the work, we focus on tailoring the constrained-TV-minimization-based reconstruction, an optimization-based reconstruction previously shown of some potential for CBCT imaging conditions of practical interest, to OBI imaging through appropriate selection of parameter values. In particular, for given real data of phantoms and patient collected with OBI CBCT, we first devise utility metrics specific to OBI-quality-assurance tasks and then apply them to guiding the selection of parameter values in constrained-TV-minimization-based reconstruction. The study results show that the reconstructions are with improvement, relative to clinical FDK reconstruction, in both visualization and quantitative assessments in terms of the devised utility metrics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The physical pattern of energy deposition and the enhanced relative biological effectiveness (RBE) of protons and carbon ions compared to photons offer unique and not fully understood or exploited opportunities to improve the efficacy of radiation therapy. Variations in RBE within a pristine or spread out Bragg peak and between particle types may be exploited to enhance cell killing in target regions without a corresponding increase in damage to normal tissue structures. In addition, the decreased sensitivity of hypoxic tumors to photon-based therapies may be partially overcome through the use of more densely ionizing radiations. These and other differences betweenmore » particle and photon beams may be used to generate biologically optimized treatments that reduce normal tissue complications. In this symposium, speakers will examine the impact of the RBE of charged particles on measurable biological endpoints, treatment plan optimization, and the prediction or retrospective assessment of treatment outcomes. In particular, an AAPM task group was formed to critically examine the evidence for a spatially-variant RBE in proton therapy. Current knowledge of proton RBE variation with respect to dose, biological endpoint, and physics parameters will be reviewed. Further, the clinical relevance of these variations will be discussed. Recent work focused on improving simulations of radiation physics and biological response in proton and carbon ion therapy will also be presented. Finally, relevant biology research and areas of research needs will be highlighted, including the dependence of RBE on genetic factors including status of DNA repair pathways, the sensitivity of cancer stem-like cells to charged particles, the role of charged particles in hypoxic tumors, and the importance of fractionation effects. In addition to the physical advantages of protons and more massive ions over photons, the future application of biologically optimized treatment plans and their potential to provide higher levels of local tumor control and improved normal tissue sparing will be discussed. Learning Objectives: To assess whether the current practice of a constant RBE of 1.1 should be revised or maintained in proton therapy and to evaluate the potential clinical consequences of delivering RBE-weighted dose distributions based on variable RBE To review current research on biological models used to predict the increased biological effectiveness of proton and carbon ions to help move towards a practical understanding and implementation of biological optimization in particle therapy To discuss potential differences in biological mechanisms between photons and charged particles (light and heavy ions) that could impact clinical cancer therapy H. Paganetti, NCI U19 CA21239D. Grosshans, Our research is supported by the NCIK. Held, Funding Support: National Cancer Institute of the National Institutes of Health, USA, under Award Number R21CA182259 and Federal Share of Program Income Earned by Massachusetts General Hospital on C06CA059267, Proton Therapy Research and Treatment Center.« less
2007-02-01
December 5, 2004, New York, New York. Cesaretti JA. “Radiation Therapy for Esophageal Carcinoma.” From Gastroesophageal Reflux Disease to...vascular diseases . However, there exists an important subset of patients with no clear explanation for excessive post-treatment morbidity and the...brachytherapy. They are entitled,” Changing the patterns of failure for high-risk prostate cancer patients by optimizing local-control”, “ Disease
Malignant glioma--a nemesis which requires clinical and basic investigation in radiation oncology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, L.W.
1989-06-01
Malignant gliomas account for 40% of all central nervous system malignancies. These are essentially localized neoplastic tumors that have defied most treatment. In spite of improved techniques, surgery is unlikely to increase survival further since true cancer operations cannot be performed. Radiation therapy has made a significant difference in outcome. Investigation in radiation oncology is essential for further improvement in the treatment of these tumors. The pattern of failure is local tumor recurrence, but the method to overcome this resistance to treatment is not clear. Radiation therapy techniques and inherent radio-resistance have been considered as possible reasons for failure. Withmore » newer imaging procedures, the extent of tumor can be more accurately defined allowing improved treatment planning. Identifying an effective treatment program is more difficult. Studies have documented the beneficial effect of radiation therapy, but the optimal dose or fractionation schedule has not been determined. Whereas some studies have reported improved survival using higher radiation doses, others have reported no benefit. More recently, studies of multiple daily fractionation schedules have been conducted using two or three daily fractions. Equally confusing results have been reported. Histologically, these tumors have necrotic areas and may be radioresistant due to hypoxic cells. Treatment methods designed to overcome the radioprotective effect of hypoxia have yielded disappointing results. The addition of hypoxic cell sensitizers has not produced the expected improvement in outcome. Studies using neutron radiation therapy report tumor control but not improved survival. Radiobiologic information is now available which may contribute to our understanding of the response of these tumors to radiation. Further laboratory and clinical investigation is required. 83 references.« less
McCowan, Peter M; Asuni, Ganiyu; Van Uytven, Eric; VanBeek, Timothy; McCurdy, Boyd M C; Loewen, Shaun K; Ahmed, Naseer; Bashir, Bashir; Butler, James B; Chowdhury, Amitava; Dubey, Arbind; Leylek, Ahmet; Nashed, Maged
2017-04-01
To report findings from an in vivo dosimetry program implemented for all stereotactic body radiation therapy patients over a 31-month period and discuss the value and challenges of utilizing in vivo electronic portal imaging device (EPID) dosimetry clinically. From December 2013 to July 2016, 117 stereotactic body radiation therapy-volumetric modulated arc therapy patients (100 lung, 15 spine, and 2 liver) underwent 602 EPID-based in vivo dose verification events. A developed model-based dose reconstruction algorithm calculates the 3-dimensional dose distribution to the patient by back-projecting the primary fluence measured by the EPID during treatment. The EPID frame-averaging was optimized in June 2015. For each treatment, a 3%/3-mm γ comparison between our EPID-derived dose and the Eclipse AcurosXB-predicted dose to the planning target volume (PTV) and the ≥20% isodose volume were performed. Alert levels were defined as γ pass rates <85% (lung and liver) and <80% (spine). Investigations were carried out for all fractions exceeding the alert level and were classified as follows: EPID-related, algorithmic, patient setup, anatomic change, or unknown/unidentified errors. The percentages of fractions exceeding the alert levels were 22.6% for lung before frame-average optimization and 8.0% for lung, 20.0% for spine, and 10.0% for liver after frame-average optimization. Overall, mean (± standard deviation) planning target volume γ pass rates were 90.7% ± 9.2%, 87.0% ± 9.3%, and 91.2% ± 3.4% for the lung, spine, and liver patients, respectively. Results from the clinical implementation of our model-based in vivo dose verification method using on-treatment EPID images is reported. The method is demonstrated to be valuable for routine clinical use for verifying delivered dose as well as for detecting errors. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yang, Ruijie; Dai, Jianrong; Yang, Yong; Hu, Yimin
2006-08-01
The purpose of this study is to extend an algorithm proposed for beam orientation optimization in classical conformal radiotherapy to intensity-modulated radiation therapy (IMRT) and to evaluate the algorithm's performance in IMRT scenarios. In addition, the effect of the candidate pool of beam orientations, in terms of beam orientation resolution and starting orientation, on the optimized beam configuration, plan quality and optimization time is also explored. The algorithm is based on the technique of mixed integer linear programming in which binary and positive float variables are employed to represent candidates for beam orientation and beamlet weights in beam intensity maps. Both beam orientations and beam intensity maps are simultaneously optimized in the algorithm with a deterministic method. Several different clinical cases were used to test the algorithm and the results show that both target coverage and critical structures sparing were significantly improved for the plans with optimized beam orientations compared to those with equi-spaced beam orientations. The calculation time was less than an hour for the cases with 36 binary variables on a PC with a Pentium IV 2.66 GHz processor. It is also found that decreasing beam orientation resolution to 10° greatly reduced the size of the candidate pool of beam orientations without significant influence on the optimized beam configuration and plan quality, while selecting different starting orientations had large influence. Our study demonstrates that the algorithm can be applied to IMRT scenarios, and better beam orientation configurations can be obtained using this algorithm. Furthermore, the optimization efficiency can be greatly increased through proper selection of beam orientation resolution and starting beam orientation while guaranteeing the optimized beam configurations and plan quality.
Hypo-Fractionated Conformal Radiation Therapy to the Tumor Bed After Segmental Mastectomy
2005-07-01
induration before RT, related to the severe kyphosis, secondary to osteoporosis. In the fourth surgery . Cosmetic results were rated as "good/excellent...Fisher B, Ore L. On the underutilization of breast-conserving 20. Abner AL, Recht A, Vicini FA, et at. Cosmetic results after surgery for the treatment of...conservative breast surgery and radio- sociated with optimal cosmetic results when performing par- therapy: Results from a randomised trial. Radiother Oncol
Hadron Cancer Therapy: Role of Nuclear Reactions
DOE R&D Accomplishments Database
Chadwick, M. B.
2000-06-20
Recently it has become feasible to calculate energy deposition and particle transport in the body by proton and neutron radiotherapy beams, using Monte Carlo transport methods. A number of advances have made this possible, including dramatic increases in computer speeds, a better understanding of the microscopic nuclear reaction cross sections, and the development of methods to model the characteristics of the radiation emerging from the accelerator treatment unit. This paper describes the nuclear reaction mechanisms involved, and how the cross sections have been evaluated from theory and experiment, for use in computer simulations of radiation therapy. The simulations will allow the dose delivered to a tumor to be optimized, whilst minimizing the dos given to nearby organs at risk.
Kaveh, Kamran; Takahashi, Yutaka; Farrar, Michael A; Storme, Guy; Guido, Marcucci; Piepenburg, Jamie; Penning, Jackson; Foo, Jasmine; Leder, Kevin Z; Hui, Susanta K
2017-07-01
Philadelphia chromosome-positive (Ph+) acute lymphoblastic leukemia (ALL) is characterized by a very poor prognosis and a high likelihood of acquired chemo-resistance. Although tyrosine kinase inhibitor (TKI) therapy has improved clinical outcome, most ALL patients relapse following treatment with TKI due to the development of resistance. We developed an in vitro model of Nilotinib-resistant Ph+ leukemia cells to investigate whether low dose radiation (LDR) in combination with TKI therapy overcome chemo-resistance. Additionally, we developed a mathematical model, parameterized by cell viability experiments under Nilotinib treatment and LDR, to explain the cellular response to combination therapy. The addition of LDR significantly reduced drug resistance both in vitro and in computational model. Decreased expression level of phosphorylated AKT suggests that the combination treatment plays an important role in overcoming resistance through the AKT pathway. Model-predicted cellular responses to the combined therapy provide good agreement with experimental results. Augmentation of LDR and Nilotinib therapy seems to be beneficial to control Ph+ leukemia resistance and the quantitative model can determine optimal dosing schedule to enhance the effectiveness of the combination therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harriss-Phillips, Wendy M., E-mail: wharrphil@gmail.com; School of Chemistry and Physics, University of Adelaide, Adelaide, South Australia; Bezak, Eva
Purpose: To simulate stereotactic ablative radiation therapy on hypoxic and well-oxygenated in silico tumors, incorporating probabilistic parameter distributions and linear-quadratic versus linear-quadratic-cubic methodology and the evaluation of optimal fractionation schemes using biological effective dose (BED{sub α/β=10} {sub or} {sub 3}) comparisons. Methods and Materials: A temporal tumor growth and radiation therapy algorithm simulated high-dose external beam radiation therapy using stochastic methods. Realistic biological proliferative cellular hierarchy and pO{sub 2} histograms were incorporated into the 10{sup 8}-cell tumor model, with randomized radiation therapy applied during continual cell proliferation and volume-based gradual tumor reoxygenation. Dose fractions ranged from 6-35 Gy, with predictive outcomes presentedmore » in terms of the total doses (converted to BED) required to eliminate all cells that could potentially regenerate the tumor. Results: Well-oxygenated tumor control BED{sub 10} outcomes were not significantly different for high-dose versus conventional radiation therapy (BED{sub 10}: 79-84 Gy; Equivalent Dose in 2 Gy fractions with α/β of 10: 66-70 Gy); however, total treatment times decreased from 7 down to 1-3 weeks. For hypoxic tumors, an additional 28 Gy (51 Gy BED{sub 10}) was required, with BED{sub 10} increasing with dose per fraction due to wasted dose in the final fraction. Fractions of 9 Gy compromised well for total treatment time and BED, with BED{sub 10}:BED{sub 3} of 84:176 Gy for oxic and 132:278 Gy for non-reoxygenating hypoxic tumors. Initial doses of 12 Gy followed by 6 Gy further increased the therapeutic ratio. When delivering ≥9 Gy per fraction, applying reoxygenation and/or linear-quadratic-cubic cell survival both affected tumor control doses by a significant 1-2 fractions. Conclusions: The complex temporal dynamics of tumor oxygenation combined with probabilistic cell kinetics in the modeling of radiation therapy requires sophisticated stochastic modeling to predict tumor cell kill. For stereotactic ablative radiation therapy, high doses in the first week followed by doses that are more moderate may be beneficial because a high percentage of hypoxic cells could be eradicated early while keeping the required BED{sub 10} relatively low and BED{sub 3} toxicity to tolerable levels.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Held, K.
The physical pattern of energy deposition and the enhanced relative biological effectiveness (RBE) of protons and carbon ions compared to photons offer unique and not fully understood or exploited opportunities to improve the efficacy of radiation therapy. Variations in RBE within a pristine or spread out Bragg peak and between particle types may be exploited to enhance cell killing in target regions without a corresponding increase in damage to normal tissue structures. In addition, the decreased sensitivity of hypoxic tumors to photon-based therapies may be partially overcome through the use of more densely ionizing radiations. These and other differences betweenmore » particle and photon beams may be used to generate biologically optimized treatments that reduce normal tissue complications. In this symposium, speakers will examine the impact of the RBE of charged particles on measurable biological endpoints, treatment plan optimization, and the prediction or retrospective assessment of treatment outcomes. In particular, an AAPM task group was formed to critically examine the evidence for a spatially-variant RBE in proton therapy. Current knowledge of proton RBE variation with respect to dose, biological endpoint, and physics parameters will be reviewed. Further, the clinical relevance of these variations will be discussed. Recent work focused on improving simulations of radiation physics and biological response in proton and carbon ion therapy will also be presented. Finally, relevant biology research and areas of research needs will be highlighted, including the dependence of RBE on genetic factors including status of DNA repair pathways, the sensitivity of cancer stem-like cells to charged particles, the role of charged particles in hypoxic tumors, and the importance of fractionation effects. In addition to the physical advantages of protons and more massive ions over photons, the future application of biologically optimized treatment plans and their potential to provide higher levels of local tumor control and improved normal tissue sparing will be discussed. Learning Objectives: To assess whether the current practice of a constant RBE of 1.1 should be revised or maintained in proton therapy and to evaluate the potential clinical consequences of delivering RBE-weighted dose distributions based on variable RBE To review current research on biological models used to predict the increased biological effectiveness of proton and carbon ions to help move towards a practical understanding and implementation of biological optimization in particle therapy To discuss potential differences in biological mechanisms between photons and charged particles (light and heavy ions) that could impact clinical cancer therapy H. Paganetti, NCI U19 CA21239D. Grosshans, Our research is supported by the NCIK. Held, Funding Support: National Cancer Institute of the National Institutes of Health, USA, under Award Number R21CA182259 and Federal Share of Program Income Earned by Massachusetts General Hospital on C06CA059267, Proton Therapy Research and Treatment Center.« less
WE-FG-BRB-01: Clinical Significance of RBE Variations in Proton Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paganetti, H.
2016-06-15
The physical pattern of energy deposition and the enhanced relative biological effectiveness (RBE) of protons and carbon ions compared to photons offer unique and not fully understood or exploited opportunities to improve the efficacy of radiation therapy. Variations in RBE within a pristine or spread out Bragg peak and between particle types may be exploited to enhance cell killing in target regions without a corresponding increase in damage to normal tissue structures. In addition, the decreased sensitivity of hypoxic tumors to photon-based therapies may be partially overcome through the use of more densely ionizing radiations. These and other differences betweenmore » particle and photon beams may be used to generate biologically optimized treatments that reduce normal tissue complications. In this symposium, speakers will examine the impact of the RBE of charged particles on measurable biological endpoints, treatment plan optimization, and the prediction or retrospective assessment of treatment outcomes. In particular, an AAPM task group was formed to critically examine the evidence for a spatially-variant RBE in proton therapy. Current knowledge of proton RBE variation with respect to dose, biological endpoint, and physics parameters will be reviewed. Further, the clinical relevance of these variations will be discussed. Recent work focused on improving simulations of radiation physics and biological response in proton and carbon ion therapy will also be presented. Finally, relevant biology research and areas of research needs will be highlighted, including the dependence of RBE on genetic factors including status of DNA repair pathways, the sensitivity of cancer stem-like cells to charged particles, the role of charged particles in hypoxic tumors, and the importance of fractionation effects. In addition to the physical advantages of protons and more massive ions over photons, the future application of biologically optimized treatment plans and their potential to provide higher levels of local tumor control and improved normal tissue sparing will be discussed. Learning Objectives: To assess whether the current practice of a constant RBE of 1.1 should be revised or maintained in proton therapy and to evaluate the potential clinical consequences of delivering RBE-weighted dose distributions based on variable RBE To review current research on biological models used to predict the increased biological effectiveness of proton and carbon ions to help move towards a practical understanding and implementation of biological optimization in particle therapy To discuss potential differences in biological mechanisms between photons and charged particles (light and heavy ions) that could impact clinical cancer therapy H. Paganetti, NCI U19 CA21239D. Grosshans, Our research is supported by the NCIK. Held, Funding Support: National Cancer Institute of the National Institutes of Health, USA, under Award Number R21CA182259 and Federal Share of Program Income Earned by Massachusetts General Hospital on C06CA059267, Proton Therapy Research and Treatment Center.« less
Perez, Bradford A; Koontz, Bridget F
2015-05-01
Men with localized high-risk prostate cancer carry significant risk of prostate cancer-specific mortality. The best treatment approach to minimize this risk is unclear. In this review, we evaluate the role of radiation before and after radical prostatectomy. A critical review of the literature was performed regarding the application of external radiation therapy (RT) in combination with prostatectomy for high-risk localized prostate cancer. Up to 70% of men with high-risk localized disease may require adjuvant therapy because of adverse pathologic features or biochemical recurrence in the absence of systemic disease. The utility of adjuvant RT among men with adverse pathologic features are well established at least regarding minimizing biochemical recurrence risk. The optimal timing of salvage radiation is the subject of ongoing studies. Neoadjuvant RT requires further study but is a potentially attractive method because of decreased radiation field sizes and potential radiobiologic benefits of delivering RT before surgery. Salvage prostatectomy is effective at treating local recurrence after radiation but is associated with significant surgical morbidity. Combining local therapies including radical prostatectomy and RT can be a reasonable approach. Care should be taken at the initial presentation of high-risk localized prostate cancer to consider and plan for the likelihood of multimodality care. Copyright © 2015 Elsevier Inc. All rights reserved.
Methionine Uptake and Required Radiation Dose to Control Glioblastoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iuchi, Toshihiko, E-mail: tiuchi@chiba-cc.jp; Hatano, Kazuo; Uchino, Yoshio
Purpose: The purpose of this study was to retrospectively assess the feasibility of radiation therapy planning for glioblastoma multiforme (GBM) based on the use of methionine (MET) positron emission tomography (PET), and the correlation among MET uptake, radiation dose, and tumor control. Methods and Materials: Twenty-two patients with GBM who underwent MET-PET prior to radiation therapy were enrolled. MET uptake in 30 regions of interest (ROIs) from 22 GBMs, biologically effective doses (BEDs) for the ROIs and their ratios (MET uptake:BED) were compared in terms of whether the ROIs were controlled for >12 months. Results: MET uptake was significantly correlated withmore » tumor control (odds ratio [OR], 10.0; P=.005); however, there was a higher level of correlation between MET uptake:BED ratio and tumor control (OR, 40.0; P<.0001). These data indicated that the required BEDs for controlling the ROIs could be predicted in terms of MET uptake; BED could be calculated as [34.0 × MET uptake] Gy from the optimal threshold of the MET uptake:BED ratio for tumor control. Conclusions: Target delineation based on MET-PET was demonstrated to be feasible for radiation therapy treatment planning. MET-PET could not only provide precise visualization of infiltrating tumor cells but also predict the required radiation doses to control target regions.« less
The peer review system (PRS) for quality assurance and treatment improvement in radiation therapy
NASA Astrophysics Data System (ADS)
Le, Anh H. T.; Kapoor, Rishabh; Palta, Jatinder R.
2012-02-01
Peer reviews are needed across all disciplines of medicine to address complex medical challenges in disease care, medical safety, insurance coverage handling, and public safety. Radiation therapy utilizes technologically advanced imaging for treatment planning, often with excellent efficacy. Since planning data requirements are substantial, patients are at risk for repeat diagnostic procedures or suboptimal therapeutic intervention due to a lack of knowledge regarding previous treatments. The Peer Review System (PRS) will make this critical radiation therapy information readily available on demand via Web technology. The PRS system has been developed with current Web technology, .NET framework, and in-house DICOM library. With the advantages of Web server-client architecture, including IIS web server, SOAP Web Services and Silverlight for the client side, the patient data can be visualized through web browser and distributed across multiple locations by the local area network and Internet. This PRS will significantly improve the quality, safety, and accessibility, of treatment plans in cancer therapy. Furthermore, the secure Web-based PRS with DICOM-RT compliance will provide flexible utilities for organization, sorting, and retrieval of imaging studies and treatment plans to optimize the patient treatment and ultimately improve patient safety and treatment quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, Eunpi; Fred Hutchinson Cancer Research Center, Seattle, Washington; Mostaghel, Elahe A.
Purpose: Optimizing androgen suppression may provide better control of localized prostate cancer (PCa). Numerous trials have supported the benefit of combining androgen deprivation therapy with definitive radiation therapy in men with locally advanced or high-grade disease. Addition of abiraterone to luteinizing hormone-releasing hormone agonist (LHRHa) with radiation has not been reported. We examined the safety of this combination as well as its impact on androgen suppression. Methods and Materials: A prospective, phase 2 study was conducted in men with localized PCa treated with 6 months of neoadjuvant and concurrent abiraterone with LHRHa and radiation. Duration of adjuvant LHRHa was at themore » discretion of the treating clinician. Prostate biopsy assays were obtained prior to the start of therapy and prior to radiation. Sera and tissue androgen levels were measured by liquid chromatography-tandem mass spectrometry. Results: A total of 22 men with intermediate- (n=3) and high-risk PCa (n=19) received study therapy. Sixteen men completed the intended course of abiraterone, and 19 men completed planned radiation to 77.4 to 81 Gy. Radiation to pelvic nodes was administered in 20 men. The following grade 3 toxicities were reported: lymphopenia (14 patients), fatigue (1 patient), transaminitis (2 patients), hypertension (2 patients), and hypokalemia (1 patient). There were no grade 4 toxicities. All 21 men who complied with at least 3 months of abiraterone therapy had a preradiation prostate-specific antigen (PSA) concentration nadir of <0.3 ng/mL. Median levels of tissue androgen downstream of CYP17A were significantly suppressed after treatment with abiraterone, and upstream steroids were increased. At median follow-up of 21 months (range: 3-37 months), only 1 patient (who had discontinued abiraterone at 3 months) had biochemical relapse. Conclusions: Addition of abiraterone to LHRHa with radiation is safe and achieves effective prostatic androgen suppression. Preliminary analysis of the clinical data is also promising, with excellent PSA nadir and no relapse to date in this high-risk population.« less
Worni, M; Castleberry, A W; Gloor, B; Pietrobon, R; Haney, J C; D'Amico, T A; Akushevich, I; Berry, M F
2014-01-01
We examined outcomes and trends in surgery and radiation use for patients with locally advanced esophageal cancer, for whom optimal treatment isn't clear. Trends in surgery and radiation for patients with T1-T3N1M0 squamous cell or adenocarcinoma of the mid or distal esophagus in the Surveillance, Epidemiology, and End Results database from 1998 to 2008 were analyzed using generalized linear models including year as predictor; Surveillance, Epidemiology, and End Results doesn't record chemotherapy data. Local treatment was unimodal if patients had only surgery or radiation and bimodal if they had both. Five-year cancer-specific survival (CSS) and overall survival (OS) were analyzed using propensity-score adjusted Cox proportional-hazard models. Overall 5-year survival for the 3295 patients identified (mean age 65.1 years, standard deviation 11.0) was 18.9% (95% confidence interval: 17.3-20.7). Local treatment was bimodal for 1274 (38.7%) and unimodal for 2021 (61.3%) patients; 1325 (40.2%) had radiation alone and 696 (21.1%) underwent only surgery. The use of bimodal therapy (32.8-42.5%, P = 0.01) and radiation alone (29.3-44.5%, P < 0.001) increased significantly from 1998 to 2008. Bimodal therapy predicted improved CSS (hazard ratios [HR]: 0.68, P < 0.001) and OS (HR: 0.58, P < 0.001) compared with unimodal therapy. For the first 7 months (before survival curve crossing), CSS after radiation therapy alone was similar to surgery alone (HR: 0.86, P = 0.12) while OS was worse for surgery only (HR: 0.70, P = 0.001). However, worse CSS (HR: 1.43, P < 0.001) and OS (HR: 1.46, P < 0.001) after that initial timeframe were found for radiation therapy only. The use of radiation to treat locally advanced mid and distal esophageal cancers increased from 1998 to 2008. Survival was best when both surgery and radiation were used. © 2013 Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hess, Clayton B.; Thompson, Holly M.; Benedict, Stanley H.
Recent improvements in toxicity profiles of pediatric oncology patients are attributable, in part, to advances in the field of radiation oncology such as intensity modulated radiation (IMRT) and proton therapy (IMPT). While IMRT and IMPT deliver highly conformal dose to targeted volumes, they commonly demand the addition of 2- or 3-dimensional imaging for precise positioning—a technique known as image guided radiation therapy (IGRT). In this manuscript we address strategies to further minimize exposure risk in children by reducing effective IGRT dose. Portal X rays and cone beam computed tomography (CBCT) are commonly used to verify patient position during IGRT and,more » because their relative radiation exposure is far less than the radiation absorbed from therapeutic treatment beams, their sometimes significant contribution to cumulative risk can be easily overlooked. Optimizing the conformality of IMRT/IMPT while simultaneously ignoring IGRT dose may result in organs at risk being exposed to a greater proportion of radiation from IGRT than from therapeutic beams. Over a treatment course, cumulative central-axis CBCT effective dose can approach or supersede the amount of radiation absorbed from a single treatment fraction, a theoretical increase of 3% to 5% in mutagenic risk. In select scenarios, this may result in the underprediction of acute and late toxicity risk (such as azoospermia, ovarian dysfunction, or increased lifetime mutagenic risk) in radiation-sensitive organs and patients. Although dependent on variables such as patient age, gender, weight, body habitus, anatomic location, and dose-toxicity thresholds, modifying IGRT use and acquisition parameters such as frequency, imaging modality, beam energy, current, voltage, rotational degree, collimation, field size, reconstruction algorithm, and documentation can reduce exposure, avoid unnecessary toxicity, and achieve doses as low as reasonably achievable, promoting a culture and practice of “gentle IGRT.”.« less
Albuquerque, Kevin; Patel, Mona; Liotta, Margaret; Harkenrider, Matthew; Guo, Rong; Small, William; Ronald, Potkul
2016-05-01
This study aimed to report on long-term effectiveness of involved field radiation therapy (IFRT) in the salvage of localized recurrent ovarian cancer (ROC). A retrospective analysis of 27 patients with a diagnosis of epithelial ovarian cancer who received tumor volume-directed IFRT for localized extraperitoneal recurrences (either as consolidation after cytoreductive surgery (CRS) or as attempted salvage if unresectable) forms the basis of this report. All patients were heavily pretreated with multiple chemotherapy regimens. Involved field radiation therapy was primarily with external beam (median dose, 50.4 Gy). Local recurrence-free survival (LRFS) was defined as freedom from in-field recurrences and was considered as a measure of effectiveness of radiotherapy. Statistical analyses evaluated association between disease-free survival, overall survival, LRFS, and various prognostic factors. Comparison was also made with a similar but unmatched cohort with localized recurrences salvaged by additional chemotherapy instead of local therapies (NIFRT group). Of 27 patients, 17 had optimal CRS before RT. The actuarial survival at 5 and 10 years (in parenthesis) from date of radiation were LRFS (70% and 60%), overall survival (30% and 19%), and disease-free survival (33% and 20%). None of the NIFRT patients survived beyond 5 years from initiation of salvage chemotherapy. Long-term follow-up in this selected series confirmed the benefit of IFRT (±CRS) in localized ROC. Chemotherapy salvage in a similar NIFRT group was not equivalent, suggesting a role for locoregional therapies in selected patients with ROC.
The impact of different dose response parameters on biologically optimized IMRT in breast cancer
NASA Astrophysics Data System (ADS)
Costa Ferreira, Brigida; Mavroidis, Panayiotis; Adamus-Górka, Magdalena; Svensson, Roger; Lind, Bengt K.
2008-05-01
The full potential of biologically optimized radiation therapy can only be maximized with the prediction of individual patient radiosensitivity prior to treatment. Unfortunately, the available biological parameters, derived from clinical trials, reflect an average radiosensitivity of the examined populations. In the present study, a breast cancer patient of stage I II with positive lymph nodes was chosen in order to analyse the effect of the variation of individual radiosensitivity on the optimal dose distribution. Thus, deviations from the average biological parameters, describing tumour, heart and lung response, were introduced covering the range of patient radiosensitivity reported in the literature. Two treatment configurations of three and seven biologically optimized intensity-modulated beams were employed. The different dose distributions were analysed using biological and physical parameters such as the complication-free tumour control probability (P+), the biologically effective uniform dose (\\bar{\\bar{D}} ), dose volume histograms, mean doses, standard deviations, maximum and minimum doses. In the three-beam plan, the difference in P+ between the optimal dose distribution (when the individual patient radiosensitivity is known) and the reference dose distribution, which is optimal for the average patient biology, ranges up to 13.9% when varying the radiosensitivity of the target volume, up to 0.9% when varying the radiosensitivity of the heart and up to 1.3% when varying the radiosensitivity of the lung. Similarly, in the seven-beam plan, the differences in P+ are up to 13.1% for the target, up to 1.6% for the heart and up to 0.9% for the left lung. When the radiosensitivity of the most important tissues in breast cancer radiation therapy was simultaneously changed, the maximum gain in outcome was as high as 7.7%. The impact of the dose response uncertainties on the treatment outcome was clinically insignificant for the majority of the simulated patients. However, the jump from generalized to individualized radiation therapy may significantly increase the therapeutic window for patients with extreme radio sensitivity or radioresistance, provided that these are identified. Even for radiosensitive patients a simple treatment technique is sufficient to maximize the outcome, since no significant benefits were obtained with a more complex technique using seven intensity-modulated beams portals.
Koontz, Bridget F; Lee, W Robert
2011-10-01
Androgen deprivation plays a major role in the treatment of prostate cancer.Preclinical studies have shown that androgen deprivation provides both an independent cytotoxic effect and radiosensitization on prostate tumors. For men with non-metastatic prostate cancer, the addition of androgen deprivation to radiotherapy has been shown to improve survival for intermediate and high risk disease compared to radiation alone.This review discusses the clinical trial data regarding combination of androgen deprivation and radiation and provides recommendations for its use in men undergoing radiotherapy for localized prostate cancer.
Salem, A; Salem, A F; Al-Ibraheem, A; Lataifeh, I; Almousa, A; Jaradat, I
2011-01-01
In recent years, the role of positron emission tomography (PET) in the staging and management of gynecological cancers has been increasing. The aim of this study was to systematically review the role of PET in radiotherapy planning and brachytherapy treatment optimization in patients with cervical cancer. Systematic literature review. Systematic review of relevant literature addressing the utilization of PET and/or PET-computed tomography (CT) in external-beam radiotherapy planning and brachytherapy treatment optimization. We performed an extensive PubMed database search on 20 April 2011. Nineteen studies, including 759 patients, formed the basis of this systematic review. PET/ PET-CT is the most sensitive imaging modality for detecting nodal metastases in patients with cervical cancer and has been shown to impact external-beam radiotherapy planning by modifying the treatment field and customizing the radiation dose. This particularly applies to detection of previously uncovered para-aortic and inguinal nodal metastases. Furthermore, PET/ PET-CT guided intensity-modulated radiation therapy (IMRT) allows delivery of higher doses of radiation to the primary tumor, if brachytherapy is unsuitable, and to grossly involved nodal disease while minimizing treatment-related toxicity. PET/ PET-CT based brachytherapy optimization allows improved tumor-volume dose distribution and detailed 3D dosimetric evaluation of risk organs. Sequential PET/ PET-CT imaging performed during the course of brachytherapy form the basis of âadaptiveâ brachytherapy in cervical cancer. This review demonstrates the effectiveness of pretreatment PET/ PET-CT in cervical cancer patients treated by radiotherapy. Further prospective studies are required to define the group of patients who would benefit the most from this procedure.
Simple tool for prediction of parotid gland sparing in intensity-modulated radiation therapy.
Gensheimer, Michael F; Hummel-Kramer, Sharon M; Cain, David; Quang, Tony S
2015-01-01
Sparing one or both parotid glands is a key goal when planning head and neck cancer radiation treatment. If the planning target volume (PTV) overlaps one or both parotid glands substantially, it may not be possible to achieve adequate gland sparing. This finding results in physicians revising their PTV contours after an intensity-modulated radiation therapy (IMRT) plan has been run and reduces workflow efficiency. We devised a simple formula for predicting mean parotid gland dose from the overlap of the parotid gland and isotropically expanded PTV contours. We tested the tool using 44 patients from 2 institutions and found agreement between predicted and actual parotid gland doses (mean absolute error = 5.3 Gy). This simple method could increase treatment planning efficiency by improving the chance that the first plan presented to the physician will have optimal parotid gland sparing. Published by Elsevier Inc.
Simple tool for prediction of parotid gland sparing in intensity-modulated radiation therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gensheimer, Michael F.; Hummel-Kramer, Sharon M., E-mail: sharonhummel@comcast.net; Cain, David
Sparing one or both parotid glands is a key goal when planning head and neck cancer radiation treatment. If the planning target volume (PTV) overlaps one or both parotid glands substantially, it may not be possible to achieve adequate gland sparing. This finding results in physicians revising their PTV contours after an intensity-modulated radiation therapy (IMRT) plan has been run and reduces workflow efficiency. We devised a simple formula for predicting mean parotid gland dose from the overlap of the parotid gland and isotropically expanded PTV contours. We tested the tool using 44 patients from 2 institutions and found agreementmore » between predicted and actual parotid gland doses (mean absolute error = 5.3 Gy). This simple method could increase treatment planning efficiency by improving the chance that the first plan presented to the physician will have optimal parotid gland sparing.« less
Simultaneous beam sampling and aperture shape optimization for SPORT.
Zarepisheh, Masoud; Li, Ruijiang; Ye, Yinyu; Xing, Lei
2015-02-01
Station parameter optimized radiation therapy (SPORT) was recently proposed to fully utilize the technical capability of emerging digital linear accelerators, in which the station parameters of a delivery system, such as aperture shape and weight, couch position/angle, gantry/collimator angle, can be optimized simultaneously. SPORT promises to deliver remarkable radiation dose distributions in an efficient manner, yet there exists no optimization algorithm for its implementation. The purpose of this work is to develop an algorithm to simultaneously optimize the beam sampling and aperture shapes. The authors build a mathematical model with the fundamental station point parameters as the decision variables. To solve the resulting large-scale optimization problem, the authors devise an effective algorithm by integrating three advanced optimization techniques: column generation, subgradient method, and pattern search. Column generation adds the most beneficial stations sequentially until the plan quality improvement saturates and provides a good starting point for the subsequent optimization. It also adds the new stations during the algorithm if beneficial. For each update resulted from column generation, the subgradient method improves the selected stations locally by reshaping the apertures and updating the beam angles toward a descent subgradient direction. The algorithm continues to improve the selected stations locally and globally by a pattern search algorithm to explore the part of search space not reachable by the subgradient method. By combining these three techniques together, all plausible combinations of station parameters are searched efficiently to yield the optimal solution. A SPORT optimization framework with seamlessly integration of three complementary algorithms, column generation, subgradient method, and pattern search, was established. The proposed technique was applied to two previously treated clinical cases: a head and neck and a prostate case. It significantly improved the target conformality and at the same time critical structure sparing compared with conventional intensity modulated radiation therapy (IMRT). In the head and neck case, for example, the average PTV coverage D99% for two PTVs, cord and brainstem max doses, and right parotid gland mean dose were improved, respectively, by about 7%, 37%, 12%, and 16%. The proposed method automatically determines the number of the stations required to generate a satisfactory plan and optimizes simultaneously the involved station parameters, leading to improved quality of the resultant treatment plans as compared with the conventional IMRT plans.
Simultaneous beam sampling and aperture shape optimization for SPORT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zarepisheh, Masoud; Li, Ruijiang; Xing, Lei, E-mail: Lei@stanford.edu
Purpose: Station parameter optimized radiation therapy (SPORT) was recently proposed to fully utilize the technical capability of emerging digital linear accelerators, in which the station parameters of a delivery system, such as aperture shape and weight, couch position/angle, gantry/collimator angle, can be optimized simultaneously. SPORT promises to deliver remarkable radiation dose distributions in an efficient manner, yet there exists no optimization algorithm for its implementation. The purpose of this work is to develop an algorithm to simultaneously optimize the beam sampling and aperture shapes. Methods: The authors build a mathematical model with the fundamental station point parameters as the decisionmore » variables. To solve the resulting large-scale optimization problem, the authors devise an effective algorithm by integrating three advanced optimization techniques: column generation, subgradient method, and pattern search. Column generation adds the most beneficial stations sequentially until the plan quality improvement saturates and provides a good starting point for the subsequent optimization. It also adds the new stations during the algorithm if beneficial. For each update resulted from column generation, the subgradient method improves the selected stations locally by reshaping the apertures and updating the beam angles toward a descent subgradient direction. The algorithm continues to improve the selected stations locally and globally by a pattern search algorithm to explore the part of search space not reachable by the subgradient method. By combining these three techniques together, all plausible combinations of station parameters are searched efficiently to yield the optimal solution. Results: A SPORT optimization framework with seamlessly integration of three complementary algorithms, column generation, subgradient method, and pattern search, was established. The proposed technique was applied to two previously treated clinical cases: a head and neck and a prostate case. It significantly improved the target conformality and at the same time critical structure sparing compared with conventional intensity modulated radiation therapy (IMRT). In the head and neck case, for example, the average PTV coverage D99% for two PTVs, cord and brainstem max doses, and right parotid gland mean dose were improved, respectively, by about 7%, 37%, 12%, and 16%. Conclusions: The proposed method automatically determines the number of the stations required to generate a satisfactory plan and optimizes simultaneously the involved station parameters, leading to improved quality of the resultant treatment plans as compared with the conventional IMRT plans.« less
WE-FG-BRB-02: Spatial Mapping of the RBE of Scanned Particle Beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grosshans, D.
2016-06-15
The physical pattern of energy deposition and the enhanced relative biological effectiveness (RBE) of protons and carbon ions compared to photons offer unique and not fully understood or exploited opportunities to improve the efficacy of radiation therapy. Variations in RBE within a pristine or spread out Bragg peak and between particle types may be exploited to enhance cell killing in target regions without a corresponding increase in damage to normal tissue structures. In addition, the decreased sensitivity of hypoxic tumors to photon-based therapies may be partially overcome through the use of more densely ionizing radiations. These and other differences betweenmore » particle and photon beams may be used to generate biologically optimized treatments that reduce normal tissue complications. In this symposium, speakers will examine the impact of the RBE of charged particles on measurable biological endpoints, treatment plan optimization, and the prediction or retrospective assessment of treatment outcomes. In particular, an AAPM task group was formed to critically examine the evidence for a spatially-variant RBE in proton therapy. Current knowledge of proton RBE variation with respect to dose, biological endpoint, and physics parameters will be reviewed. Further, the clinical relevance of these variations will be discussed. Recent work focused on improving simulations of radiation physics and biological response in proton and carbon ion therapy will also be presented. Finally, relevant biology research and areas of research needs will be highlighted, including the dependence of RBE on genetic factors including status of DNA repair pathways, the sensitivity of cancer stem-like cells to charged particles, the role of charged particles in hypoxic tumors, and the importance of fractionation effects. In addition to the physical advantages of protons and more massive ions over photons, the future application of biologically optimized treatment plans and their potential to provide higher levels of local tumor control and improved normal tissue sparing will be discussed. Learning Objectives: To assess whether the current practice of a constant RBE of 1.1 should be revised or maintained in proton therapy and to evaluate the potential clinical consequences of delivering RBE-weighted dose distributions based on variable RBE To review current research on biological models used to predict the increased biological effectiveness of proton and carbon ions to help move towards a practical understanding and implementation of biological optimization in particle therapy To discuss potential differences in biological mechanisms between photons and charged particles (light and heavy ions) that could impact clinical cancer therapy H. Paganetti, NCI U19 CA21239D. Grosshans, Our research is supported by the NCIK. Held, Funding Support: National Cancer Institute of the National Institutes of Health, USA, under Award Number R21CA182259 and Federal Share of Program Income Earned by Massachusetts General Hospital on C06CA059267, Proton Therapy Research and Treatment Center.« less
Radioimmunotherapy as the first line of treatment in non-Hodgkin lymphoma.
Eskian, Mahsa; Khorasanizadeh, MirHojjat; Zinzani, Pier L; Rezaei, Nima
2018-06-01
Non-Hodgkin lymphoma (NHL) is the most common hematologic malignancy. The estimated deaths and new cases of NHL in the USA in 2018 have reached 19,910 and 74,680, respectively, with 5-year survival rate of 71%. Therapeutic interventions for NHL consist of chemotherapy, radiation therapy and immunotherapy. Radioimmunotherapy (RIT) is a potential alternative treatment for NHL that is currently used in different lines of treatment. Studies show that nuclear medicine physicians and radiation oncologists are not yet certain about the proper line for administration of RIT. Herein, we have reviewed the efficiency and toxicity of RIT as the first line of treatment, and discussed potential novel indications, and strategies such as modifying induction therapy and using rituximab maintenance to optimize the efficiency of RIT as the first line of treatment. Our review indicates that it is more logical to postpone conventional therapies to the second or third lines of treatment instead of RIT.
The role of chemotherapy in the treatment of malignant astrocytomas.
Mathieu, David; Fortin, David
2006-05-01
Malignant astrocytomas are aggressive neoplasms with a dismal prognosis despite optimal treatment. Maximal resective surgery is traditionally complemented by radiation therapy. Chemotherapy is now used on patients as initial therapy when their functional status is congruent with further treatment. The classic agents used are nitrosoureas, but temozolomide has taken the front seat recently, with recent data demonstrating increased survival when this agent is used concurrently with radiation therapy in newly diagnosed glioblastoma patients. A new class of agents, refered to as biological modifiers, are increasingly used in clinical trials in an effort to affect the intrinsic biologic aberrations harboured by tumor cells. These drugs comprise differentiation agents, anti-angiogenic agents, matrix-metalloproteinase inhibitors and signal transduction inhibitors, among others. This article reviews the standard cytotoxic agents that have been used to treat malignant astrocytomas, and the different combination regimens offering promise. In addition, recent advances with biological modifiers are also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rossi, Linda, E-mail: l.rossi@erasmusmc.nl; Breedveld, Sebastiaan; Aluwini, Shafak
Purpose: To investigate development of a recipe for the creation of a beam angle class solution (CS) for noncoplanar prostate stereotactic body radiation therapy to replace time-consuming individualized beam angle selection (iBAS) without significant loss in plan quality, using the in-house “Erasmus-iCycle” optimizer for fully automated beam profile optimization and iBAS. Methods and Materials: For 30 patients, Erasmus-iCycle was first used to generate 15-, 20-, and 25-beam iBAS plans for a CyberKnife equipped with a multileaf collimator. With these plans, 6 recipes for creation of beam angle CSs were investigated. Plans of 10 patients were used to create CSs based on themore » recipes, and the other 20 to independently test them. For these tests, Erasmus-iCycle was also used to generate intensity modulated radiation therapy plans for the fixed CS beam setups. Results: Of the tested recipes for CS creation, only 1 resulted in 15-, 20-, and 25-beam noncoplanar CSs without plan deterioration compared with iBAS. For the patient group, mean differences in rectum D{sub 1cc}, V{sub 60GyEq}, V{sub 40GyEq}, and D{sub mean} between 25-beam CS plans and 25-beam plans generated with iBAS were 0.2 ± 0.4 Gy, 0.1% ± 0.2%, 0.2% ± 0.3%, and 0.1 ± 0.2 Gy, respectively. Differences between 15- and 20-beam CS and iBAS plans were also negligible. Plan quality for CS plans relative to iBAS plans was also preserved when narrower planning target volume margins were arranged and when planning target volume dose inhomogeneity was decreased. Using a CS instead of iBAS reduced the computation time by a factor of 14 to 25, mainly depending on beam number, without loss in plan quality. Conclusions: A recipe for creation of robust beam angle CSs for robotic prostate stereotactic body radiation therapy has been developed. Compared with iBAS, computation times decreased by a factor 14 to 25. The use of a CS may avoid long planning times without losses in plan quality.« less
Monte Carlo study of microdosimetric diamond detectors
NASA Astrophysics Data System (ADS)
Solevi, Paola; Magrin, Giulio; Moro, Davide; Mayer, Ramona
2015-09-01
Ion-beam therapy provides a high dose conformity and increased radiobiological effectiveness with respect to conventional radiation-therapy. Strict constraints on the maximum uncertainty on the biological weighted dose and consequently on the biological weighting factor require the determination of the radiation quality, defined as the types and energy spectra of the radiation at a specific point. However the experimental determination of radiation quality, in particular for an internal target, is not simple and the features of ion interactions and treatment delivery require dedicated and optimized detectors. Recently chemical vapor deposition (CVD) diamond detectors have been suggested as ion-beam therapy microdosimeters. Diamond detectors can be manufactured with small cross sections and thin shapes, ideal to cope with the high fluence rate. However the sensitive volume of solid state detectors significantly deviates from conventional microdosimeters, with a diameter that can be up to 1000 times the height. This difference requires a redefinition of the concept of sensitive thickness and a deep study of the secondary to primary radiation, of the wall effects and of the impact of the orientation of the detector with respect to the radiation field. The present work intends to study through Monte Carlo simulations the impact of the detector geometry on the determination of radiation quality quantities, in particular on the relative contribution of primary and secondary radiation. The dependence of microdosimetric quantities such as the unrestricted linear energy L and the lineal energy y are investigated for different detector cross sections, by varying the particle type (carbon ions and protons) and its energy.
Filippi, Andrea Riccardo; Ragona, Riccardo; Piva, Cristina; Scafa, Davide; Fiandra, Christian; Fusella, Marco; Giglioli, Francesca Romana; Lohr, Frank; Ricardi, Umberto
2015-05-01
The purpose of this study was to evaluate the risks of second cancers and cardiovascular diseases associated with an optimized volumetric modulated arc therapy (VMAT) planning solution in a selected cohort of stage I/II Hodgkin lymphoma (HL) patients treated with either involved-node or involved-site radiation therapy in comparison with 3-dimensional conformal radiation therapy (3D-CRT). Thirty-eight patients (13 males and 25 females) were included. Disease extent was mediastinum alone (n=8, 21.1%); mediastinum plus unilateral neck (n=19, 50%); mediastinum plus bilateral neck (n=11, 29.9%). Prescription dose was 30 Gy in 2-Gy fractions. Only 5 patients had mediastinal bulky disease at diagnosis (13.1%). Anteroposterior 3D-CRT was compared with a multiarc optimized VMAT solution. Lung, breast, and thyroid cancer risks were estimated by calculating a lifetime attributable risk (LAR), with a LAR ratio (LAR(VMAT)-to-LAR(3D-CRT)) as a comparative measure. Cardiac toxicity risks were estimated by calculating absolute excess risk (AER). The LAR ratio favored 3D-CRT for lung cancer induction risk in mediastinal alone (P=.004) and mediastinal plus unilateral neck (P=.02) presentations. LAR ratio for breast cancer was lower for VMAT in mediastinal plus bilateral neck presentations (P=.02), without differences for other sites. For thyroid cancer, no significant differences were observed, regardless of anatomical presentation. A significantly lower AER of cardiac (P=.038) and valvular diseases (P<.0001) was observed for VMAT regardless of disease extent. In a cohort of patients with favorable characteristics in terms of disease extent at diagnosis (large prevalence of nonbulky presentations without axillary involvement), optimized VMAT reduced heart disease risk with comparable risks of thyroid and breast cancer, with an increase in lung cancer induction probability. The results are however strongly influenced by the different anatomical presentations, supporting an individualized approach. Copyright © 2015 Elsevier Inc. All rights reserved.
Communication of benefits and risks of medical radiation: a historical perspective.
Timins, Julie K
2011-11-01
X-rays were discovered by Wilhelm Röntgen in 1895. Within one year, benefits of x-rays, such as visualization of fractures, and detriments, such as x-ray dermatitis, were recognized. Nobel Laureates Pierre and Marie Sklodowska Curie discovered the radioactive element radium in 1898, and a year later the application of radiation to cure cancer was reported. A significant price was paid for this: Marie Curie died of aplastic anemia related to her radiation exposure, and her daughter Irene Joliot Curie, Nobelist for radiochemical research, died of radiation-induced leukemia. Internationally developed radiation protection recommendations were formalized starting in the late 1920s. The increasing use of ionizing radiation in medical diagnosis and radiation therapy has brought significant societal benefits. Known risks of therapeutic radiation include coronary artery disease and secondary malignancy. However, recently concerns have been raised of possible very small but incremental increases in malignancies due to diagnostic medical radiation. Patients are largely unaware of, and referring physicians and even radiologists often underestimate, the carcinogenic effects of radiation. There is a need to determine the appropriateness of imaging tests that use ionizing radiation prior to performance; optimize imaging protocols to reduce unnecessary radiation; include patients in the decision process and encourage and enable them to track their radiation exposure; and promote education about medical radiation to patients, referring physicians, radiologists, and members of the public. The basic radiation protection principles of justification, optimization, and application of dose limits still pertain.
Paradis, Eric; Cao, Yue; Lawrence, Theodore S; Tsien, Christina; Feng, Mary; Vineberg, Karen; Balter, James M
2015-12-01
The purpose of this study was to assess the dosimetric accuracy of synthetic CT (MRCT) volumes generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy. A study was conducted in 12 patients with gliomas who underwent both MR and CT imaging as part of their simulation for external beam treatment planning. MRCT volumes were generated from MR images. Patients' clinical treatment planning directives were used to create 12 individual volumetric modulated arc therapy (VMAT) plans, which were then optimized 10 times on each of their respective CT and MRCT-derived electron density maps. Dose metrics derived from optimization criteria, as well as monitor units and gamma analyses, were evaluated to quantify differences between the imaging modalities. Mean differences between planning target volume (PTV) doses on MRCT and CT plans across all patients were 0.0% (range: -0.1 to 0.2%) for D(95%); 0.0% (-0.7 to 0.6%) for D(5%); and -0.2% (-1.0 to 0.2%) for D(max). MRCT plans showed no significant changes in monitor units (-0.4%) compared to CT plans. Organs at risk (OARs) had average D(max) differences of 0.0 Gy (-2.2 to 1.9 Gy) over 85 structures across all 12 patients, with no significant differences when calculated doses approached planning constraints. Focal brain VMAT plans optimized on MRCT images show excellent dosimetric agreement with standard CT-optimized plans. PTVs show equivalent coverage, and OARs do not show any overdose. These results indicate that MRI-derived synthetic CT volumes can be used to support treatment planning of most patients treated for intracranial lesions. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paradis, Eric, E-mail: eparadis@umich.edu; Cao, Yue; Department of Radiology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan
2015-12-01
Purpose: The purpose of this study was to assess the dosimetric accuracy of synthetic CT (MRCT) volumes generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy. Methods and Materials: A study was conducted in 12 patients with gliomas who underwent both MR and CT imaging as part of their simulation for external beam treatment planning. MRCT volumes were generated from MR images. Patients' clinical treatment planning directives were used to create 12 individual volumetric modulated arc therapy (VMAT) plans, which were then optimized 10 times on each of their respective CT and MRCT-derived electron density maps. Dosemore » metrics derived from optimization criteria, as well as monitor units and gamma analyses, were evaluated to quantify differences between the imaging modalities. Results: Mean differences between planning target volume (PTV) doses on MRCT and CT plans across all patients were 0.0% (range: −0.1 to 0.2%) for D{sub 95%}; 0.0% (−0.7 to 0.6%) for D{sub 5%}; and −0.2% (−1.0 to 0.2%) for D{sub max}. MRCT plans showed no significant changes in monitor units (−0.4%) compared to CT plans. Organs at risk (OARs) had average D{sub max} differences of 0.0 Gy (−2.2 to 1.9 Gy) over 85 structures across all 12 patients, with no significant differences when calculated doses approached planning constraints. Conclusions: Focal brain VMAT plans optimized on MRCT images show excellent dosimetric agreement with standard CT-optimized plans. PTVs show equivalent coverage, and OARs do not show any overdose. These results indicate that MRI-derived synthetic CT volumes can be used to support treatment planning of most patients treated for intracranial lesions.« less
Automated IMRT planning with regional optimization using planning scripts
Wong, Eugene; Bzdusek, Karl; Lock, Michael; Chen, Jeff Z.
2013-01-01
Intensity‐modulated radiation therapy (IMRT) has become a standard technique in radiation therapy for treating different types of cancers. Various class solutions have been developed for simple cases (e.g., localized prostate, whole breast) to generate IMRT plans efficiently. However, for more complex cases (e.g., head and neck, pelvic nodes), it can be time‐consuming for a planner to generate optimized IMRT plans. To generate optimal plans in these more complex cases which generally have multiple target volumes and organs at risk, it is often required to have additional IMRT optimization structures such as dose limiting ring structures, adjust beam geometry, select inverse planning objectives and associated weights, and additional IMRT objectives to reduce cold and hot spots in the dose distribution. These parameters are generally manually adjusted with a repeated trial and error approach during the optimization process. To improve IMRT planning efficiency in these more complex cases, an iterative method that incorporates some of these adjustment processes automatically in a planning script is designed, implemented, and validated. In particular, regional optimization has been implemented in an iterative way to reduce various hot or cold spots during the optimization process that begins with defining and automatic segmentation of hot and cold spots, introducing new objectives and their relative weights into inverse planning, and turn this into an iterative process with termination criteria. The method has been applied to three clinical sites: prostate with pelvic nodes, head and neck, and anal canal cancers, and has shown to reduce IMRT planning time significantly for clinical applications with improved plan quality. The IMRT planning scripts have been used for more than 500 clinical cases. PACS numbers: 87.55.D, 87.55.de PMID:23318393
The role of systemic therapy in the management of sinonasal cancer: A critical review.
Bossi, Paolo; Saba, Nabil F; Vermorken, Jan B; Strojan, Primoz; Pala, Laura; de Bree, Remco; Rodrigo, Juan Pablo; Lopez, Fernando; Hanna, Ehab Y; Haigentz, Missak; Takes, Robert P; Slootweg, Piet J; Silver, Carl E; Rinaldo, Alessandra; Ferlito, Alfio
2015-12-01
Due to the rarity and the variety of histological types of sinonasal cancers, there is a paucity of data regarding strategy for their optimal treatment. Generally, outcomes of advanced and higher grade tumors remain unsatisfactory, despite the employment of sophisticated surgical approaches, technical advances in radiation techniques and the use of heavy ion particles. In this context, we critically evaluated the role of systemic therapy as part of a multidisciplinary approach to locally advanced disease. Induction chemotherapy has shown encouraging activity and could have a role in the multimodal treatment of patients with advanced sinonasal tumors. For epithelial tumors, the most frequently employed chemotherapy is cisplatin, in combination with either 5-fluorouracil, taxane, ifosfamide, or vincristine. Only limited experiences with concurrent chemoradiation exist with sinonasal cancer. The role of systemic treatment for each histological type (intestinal-type adenocarcinoma, sinonasal undifferentiated carcinoma, sinonasal neuroendocrine carcinoma, olfactory neuroblastoma, sinonasal primary mucosal melanoma, sarcoma) is discussed. The treatment of SNC requires a multimodal approach. Employment of systemic therapy for locally advanced disease could result in better outcomes, and optimize the therapeutic armamentarium. Further studies are needed to precisely define the role of systemic therapy and identify the optimal sequencing for its administration in relation to local therapies. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fu, Yuchuan; Deng, Min; Zhou, Xiaojuan
To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plansmore » were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V{sub 5}, V{sub 13}, V{sub 20}, mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V{sub 30} for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated radiation therapy technique.« less
Punjabi, Amol; Wu, Xiang; Tokatli-Apollon, Amira; ...
2014-09-25
A class of biocompatible upconverting nanoparticles (UCNPs) with largely amplified red-emissions was developed. The optimal UCNP shows a high absolute upconversion quantum yield of 3.2% in red-emission, which is 15-fold stronger than the known optimal β-phase core/shell UCNPs. When conjugated to aminolevulinic acid, a clinically used photodynamic therapy (PDT) prodrug, significant PDT effect in tumor was demonstrated in a deep-tissue (>1.2 cm) setting in vivo at a biocompatible laser power density. Furthermore, we show that our UCNP–PDT system with NIR irradiation outperforms clinically used red light irradiation in a deep tumor setting in vivo. This study marks a major stepmore » forward in photodynamic therapy utilizing UCNPs to effectively access deep-set tumors.Lastly, it also provides an opportunity for the wide application of upconverting red radiation in photonics and biophotonics.« less
Punjabi, Amol; Wu, Xiang; Tokatli-Apollon, Amira; El-Rifai, Mahmoud; Lee, Hyungseok; Zhang, Yuanwei; Wang, Chao; Liu, Zhuang; Chan, Emory M; Duan, Chunying; Han, Gang
2014-10-28
A class of biocompatible upconverting nanoparticles (UCNPs) with largely amplified red-emissions was developed. The optimal UCNP shows a high absolute upconversion quantum yield of 3.2% in red-emission, which is 15-fold stronger than the known optimal β-phase core/shell UCNPs. When conjugated to aminolevulinic acid, a clinically used photodynamic therapy (PDT) prodrug, significant PDT effect in tumor was demonstrated in a deep-tissue (>1.2 cm) setting in vivo at a biocompatible laser power density. Furthermore, we show that our UCNP-PDT system with NIR irradiation outperforms clinically used red light irradiation in a deep tumor setting in vivo. This study marks a major step forward in photodynamic therapy utilizing UCNPs to effectively access deep-set tumors. It also provides an opportunity for the wide application of upconverting red radiation in photonics and biophotonics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Punjabi, Amol; Wu, Xiang; Tokatli-Apollon, Amira
A class of biocompatible upconverting nanoparticles (UCNPs) with largely amplified red-emissions was developed. The optimal UCNP shows a high absolute upconversion quantum yield of 3.2% in red-emission, which is 15-fold stronger than the known optimal β-phase core/shell UCNPs. When conjugated to aminolevulinic acid, a clinically used photodynamic therapy (PDT) prodrug, significant PDT effect in tumor was demonstrated in a deep-tissue (>1.2 cm) setting in vivo at a biocompatible laser power density. Furthermore, we show that our UCNP–PDT system with NIR irradiation outperforms clinically used red light irradiation in a deep tumor setting in vivo. This study marks a major stepmore » forward in photodynamic therapy utilizing UCNPs to effectively access deep-set tumors.Lastly, it also provides an opportunity for the wide application of upconverting red radiation in photonics and biophotonics.« less
Matthews, Ellyn E; Cook, Paul F
2009-07-01
The impact of diagnosis and treatment for breast cancer, stressors that affect emotional well-being, is influenced by several psychosocial factors and the relationships among them. The purpose of this study was to investigate the relationship between optimism and emotional well-being (EWB) and the individual and combined mediation of this relationship by perceived social support (SS), problem focused coping (PFC), and self-transcendence in women with breast cancer during radiation therapy. Ninety-three women receiving radiation treatment for breast cancer completed questionnaires that measured EWB, optimism, SS, PFC, and self-transcendence. Correlational and multiple regression analysis revealed that optimism was positively related to EWB. Of the three mediators, self-transcendence alone was found to partially mediate the relationship between optimism and EWB. The relationship between optimism and PFC was not significant. Optimism was related to SS, but its indirect effect on EWB through SS did not reach significance. During breast cancer treatment, the positive effects of optimism on EWB are partially mediated by a woman's level of self-transcendence. Brief screening of women's optimism may help identify women at risk for psychological distress. Early detection and interventions to promote psychological adjustment throughout the cancer trajectory (e.g. enhancing self-transcendence) should receive attention in future research. (c) 2008 John Wiley & Sons, Ltd.
Malaguarnera, Giulia; Madeddu, Roberto; Catania, Vito Emanuele; Bertino, Gaetano; Morelli, Luca; Perrotta, Rosario Emanuele; Drago, Filippo; Malaguarnera, Michele; Latteri, Saverio
2018-01-01
Anorectal melanoma is an uncommon and aggressive mucosal melanocytic malignancy. Due to its rarity, the pre-operative diagnosis remains difficult. The first symptoms are non-specific such as anal bleeding, anal mass or pain. Although anorectal melanoma carries a poor prognosis; optimal therapeutics strategies are unclear. Surgical resection remains the mainstay of treatment. The optimal surgical procedure for primary tumours is controversial and can vary from wide local excision or endoscopic mucosal resection (EMR) to an abdomino-perineal resection. A high degree of uncertainly exists regarding the benefit of radiation therapy or chemotherapy. The treatment of advanced melanoma is evolving rapidly with better understanding of the disease biology and immunology. Considerable effort has been devoted to the identification of molecular determinants of response to target therapies and immunotherapy. PMID:29492238
Chen, Huixiao; Winey, Brian A; Daartz, Juliane; Oh, Kevin S; Shin, John H; Gierga, David P
2015-01-01
To evaluate plan quality and delivery efficiency gains of volumetric modulated arc therapy (VMAT) versus a multicriteria optimization-based intensity modulated radiation therapy (MCO-IMRT) for stereotactic radiosurgery of spinal metastases. MCO-IMRT plans (RayStation V2.5; RaySearch Laboratories, Stockholm, Sweden) of 10 spinal radiosurgery cases using 7-9 beams were developed for clinical delivery, and patients were replanned using VMAT with partial arcs. The prescribed dose was 18 Gy, and target coverage was maximized such that the maximum dose to the planning organ-at-risk volume (PRV) of the spinal cord was 10 or 12 Gy. Dose-volume histogram (DVH) constraints from the clinically acceptable MCO-IMRT plans were utilized for VMAT optimization. Plan quality and delivery efficiency with and without collimator rotation for MCO-IMRT and VMAT were compared and analyzed based upon DVH, planning target volume coverage, homogeneity index, conformity number, cord PRV sparing, total monitor units (MU), and delivery time. The VMAT plans were capable of matching most DVH constraints from the MCO-IMRT plans. The ranges of MU were 4808-7193 for MCO-IMRT without collimator rotation, 3509-5907 for MCO-IMRT with collimator rotation, 4444-7309 for VMAT without collimator rotation, and 3277-5643 for VMAT with collimator of 90 degrees. The MU for the VMAT plans were similar to their corresponding MCO-IMRT plans, depending upon the complexity of the target and PRV geometries, but had a larger range. The delivery times of the MCO-IMRT and VMAT plans, both with collimator rotation, were 18.3 ± 2.5 minutes and 14.2 ± 2.0 minutes, respectively (P < .05). The MCO-IMRT and VMAT can create clinically acceptable plans for spinal radiosurgery. The MU for MCO-IMRT and VMAT can be reduced significantly by utilizing a collimator rotation following the orientation of the spinal cord. Plan quality for VMAT is similar to MCO-IMRT, with similar MU for both modalities. Delivery times can be reduced by nominally 25% with VMAT. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
EUD-based biological optimization for carbon ion therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brüningk, Sarah C., E-mail: sarah.brueningk@icr.ac.uk; Kamp, Florian; Wilkens, Jan J.
2015-11-15
Purpose: Treatment planning for carbon ion therapy requires an accurate modeling of the biological response of each tissue to estimate the clinical outcome of a treatment. The relative biological effectiveness (RBE) accounts for this biological response on a cellular level but does not refer to the actual impact on the organ as a whole. For photon therapy, the concept of equivalent uniform dose (EUD) represents a simple model to take the organ response into account, yet so far no formulation of EUD has been reported that is suitable to carbon ion therapy. The authors introduce the concept of an equivalentmore » uniform effect (EUE) that is directly applicable to both ion and photon therapies and exemplarily implemented it as a basis for biological treatment plan optimization for carbon ion therapy. Methods: In addition to a classical EUD concept, which calculates a generalized mean over the RBE-weighted dose distribution, the authors propose the EUE to simplify the optimization process of carbon ion therapy plans. The EUE is defined as the biologically equivalent uniform effect that yields the same probability of injury as the inhomogeneous effect distribution in an organ. Its mathematical formulation is based on the generalized mean effect using an effect-volume parameter to account for different organ architectures and is thus independent of a reference radiation. For both EUD concepts, quadratic and logistic objective functions are implemented into a research treatment planning system. A flexible implementation allows choosing for each structure between biological effect constraints per voxel and EUD constraints per structure. Exemplary treatment plans are calculated for a head-and-neck patient for multiple combinations of objective functions and optimization parameters. Results: Treatment plans optimized using an EUE-based objective function were comparable to those optimized with an RBE-weighted EUD-based approach. In agreement with previous results from photon therapy, the optimization by biological objective functions resulted in slightly superior treatment plans in terms of final EUD for the organs at risk (OARs) compared to voxel-based optimization approaches. This observation was made independent of the underlying objective function metric. An absolute gain in OAR sparing was observed for quadratic objective functions, whereas intersecting DVHs were found for logistic approaches. Even for considerable under- or overestimations of the used effect- or dose–volume parameters during the optimization, treatment plans were obtained that were of similar quality as the results of a voxel-based optimization. Conclusions: EUD-based optimization with either of the presented concepts can successfully be applied to treatment plan optimization. This makes EUE-based optimization for carbon ion therapy a useful tool to optimize more specifically in the sense of biological outcome while voxel-to-voxel variations of the biological effectiveness are still properly accounted for. This may be advantageous in terms of computational cost during treatment plan optimization but also enables a straight forward comparison of different fractionation schemes or treatment modalities.« less
A comprehensive formulation for volumetric modulated arc therapy planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nguyen, Dan; Lyu, Qihui; Ruan, Dan
2016-07-15
Purpose: Volumetric modulated arc therapy (VMAT) is a widely employed radiation therapy technique, showing comparable dosimetry to static beam intensity modulated radiation therapy (IMRT) with reduced monitor units and treatment time. However, the current VMAT optimization has various greedy heuristics employed for an empirical solution, which jeopardizes plan consistency and quality. The authors introduce a novel direct aperture optimization method for VMAT to overcome these limitations. Methods: The comprehensive VMAT (comVMAT) planning was formulated as an optimization problem with an L2-norm fidelity term to penalize the difference between the optimized dose and the prescribed dose, as well as an anisotropicmore » total variation term to promote piecewise continuity in the fluence maps, preparing it for direct aperture optimization. A level set function was used to describe the aperture shapes and the difference between aperture shapes at adjacent angles was penalized to control MLC motion range. A proximal-class optimization solver was adopted to solve the large scale optimization problem, and an alternating optimization strategy was implemented to solve the fluence intensity and aperture shapes simultaneously. Single arc comVMAT plans, utilizing 180 beams with 2° angular resolution, were generated for a glioblastoma multiforme case, a lung (LNG) case, and two head and neck cases—one with three PTVs (H&N{sub 3PTV}) and one with foue PTVs (H&N{sub 4PTV})—to test the efficacy. The plans were optimized using an alternating optimization strategy. The plans were compared against the clinical VMAT (clnVMAT) plans utilizing two overlapping coplanar arcs for treatment. Results: The optimization of the comVMAT plans had converged within 600 iterations of the block minimization algorithm. comVMAT plans were able to consistently reduce the dose to all organs-at-risk (OARs) as compared to the clnVMAT plans. On average, comVMAT plans reduced the max and mean OAR dose by 6.59% and 7.45%, respectively, of the prescription dose. Reductions in max dose and mean dose were as high as 14.5 Gy in the LNG case and 15.3 Gy in the H&N{sub 3PTV} case. PTV coverages measured by D95, D98, and D99 were within 0.25% of the prescription dose. By comprehensively optimizing all beams, the comVMAT optimizer gained the freedom to allow some selected beams to deliver higher intensities, yielding a dose distribution that resembles a static beam IMRT plan with beam orientation optimization. Conclusions: The novel nongreedy VMAT approach simultaneously optimizes all beams in an arc and then directly generates deliverable apertures. The single arc VMAT approach thus fully utilizes the digital Linac’s capability in dose rate and gantry rotation speed modulation. In practice, the new single VMAT algorithm generates plans superior to existing VMAT algorithms utilizing two arcs.« less
How Advances in Imaging Will Affect Precision Radiation Oncology.
Jaffray, David A; Das, Shiva; Jacobs, Paula M; Jeraj, Robert; Lambin, Philippe
2018-06-01
Radiation oncology is 1 of the most structured disciplines in medicine. It is of a highly technical nature with reliance on robotic systems to deliver intervention, engagement of diverse expertise, and early adoption of digital approaches to optimize and execute the application of this highly effective cancer treatment. As a localized intervention, the dependence on sensitive, specific, and accurate imaging to define the extent of disease, its heterogeneity, and adjacency to normal tissues directly affects the therapeutic ratio. Image-based in vivo temporal monitoring of the response to treatment enables adaptation and further affects the therapeutic ratio. Thus, more precise intervention will enable fractionation schedules that better interoperate with advances such as immunotherapy. In the data set-rich era that promises precision and personalized medicine, the radiation oncology field will integrate these new data into highly protocoled pathways of care that begin with multimodality prediction and enable patient-specific adaptation of therapy based on quantitative measures of the individual's dose-volume temporal trajectory and midtherapy predictions of response. In addition to advancements in computed tomography imaging, emerging technologies, such as ultra-high-field magnetic resonance and molecular imaging will bring new information to the design of treatments. Next-generation image guided radiation therapy systems will inject high specificity and sensitivity data and stimulate adaptive replanning. In addition, a myriad of pre- and peritherapeutic markers derived from advances in molecular pathology (eg, tumor genomics), automated and comprehensive imaging analytics (eg, radiomics, tumor microenvironment), and many other emerging biomarkers (eg, circulating tumor cell assays) will need to be integrated to maximize the benefit of radiation therapy for an individual patient. We present a perspective on the promise and challenges of fully exploiting imaging data in the pursuit of personalized radiation therapy, drawing from the presentations and broader discussions at the 2016 American Society of Therapeutic Radiation Oncology-National Cancer Institute workshop on Precision Medicine in Radiation Oncology (Bethesda, MD). Copyright © 2018. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kozak, Kevin R.; Adams, Judith; Krejcarek, Stephanie J.
Purpose: We compared tumor and normal tissue dosimetry of proton radiation therapy with intensity-modulated radiation therapy (IMRT) for pediatric parameningeal rhabdomyosarcomas (PRMS). Methods and Materials: To quantify dosimetric differences between contemporary proton and photon treatment for pediatric PRMS, proton beam plans were compared with IMRT plans. Ten patients treated with proton radiation therapy at Massachusetts General Hospital had IMRT plans generated. To facilitate dosimetric comparisons, clinical target volumes and normal tissue volumes were held constant. Plans were optimized for target volume coverage and normal tissue sparing. Results: Proton and IMRT plans provided acceptable and comparable target volume coverage, with atmore » least 99% of the CTV receiving 95% of the prescribed dose in all cases. Improved dose conformality provided by proton therapy resulted in significant sparing of all examined normal tissues except for ipsilateral cochlea and mastoid; ipsilateral parotid gland sparing was of borderline statistical significance (p = 0.05). More profound sparing of contralateral structures by protons resulted in greater dose asymmetry between ipsilateral and contralateral retina, optic nerves, cochlea, and mastoids; dose asymmetry between ipsilateral and contralateral parotids was of borderline statistical significance (p = 0.05). Conclusions: For pediatric PRMS, superior normal tissue sparing is achieved with proton radiation therapy compared with IMRT. Because of enhanced conformality, proton plans also demonstrate greater normal tissue dose distribution asymmetry. Longitudinal studies assessing the impact of proton radiotherapy and IMRT on normal tissue function and growth symmetry are necessary to define the clinical consequences of these differences.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Åsli, Linn M., E-mail: linn.merete.asli@kreftregisteret.no; Kvaløy, Stein O.; Jetne, Vidar
2014-11-01
Purpose: To estimate actual utilization rates of radiation therapy (RT) in Norway, describe time trends (1997-2010), and compare these estimates with corresponding optimal RT rates. Methods and Materials: Data from the population-based Cancer Registry of Norway was used to identify all patients diagnosed with cancer and/or treated by RT for cancer in 1997-2010. Radiation therapy utilization rates (RURs) were calculated as (1) the proportion of incident cancer cases who received RT at least once within 1 year of diagnosis (RUR{sub 1Y}); and (2) the proportion who received RT within 5 years of diagnosis (RUR{sub 5Y}). The number of RT treatment courses per incidentmore » cancer case (TCI) was also calculated for all cancer sites combined. The actual RURs were compared with corresponding Australian and Canadian epidemiologic- and evidence-based model estimates and criterion-based benchmark estimates of optimal RURs. The TCIs were compared with TCI estimates from the 1997 Norwegian/National Cancer Plan (NCP). Joinpoint regression was used to identify changes in trends and to estimate annual percentage change (APC) in actual RUR{sub 1Y} and actual TCI. Results: The actual RUR{sub 5Y} (all sites) increased significantly to 29% in 2005 but still differed markedly from the Australian epidemiologic- and evidence-based model estimate of 48%. With the exception of RUR{sub 5Y} for breast cancer and RUR{sub 1Y} for lung cancers, all actual RURs were markedly lower than optimal RUR estimates. The actual TCI increased significantly during the study period, reaching 42.5% in 2010, but was still lower than the 54% recommended in the NCP. The trend for RUR{sub 1Y} (all sites) and TCI changed significantly, with the annual percentage change being largest during the first part of the study period. Conclusions: Utilization rates of RT in Norway increased after the NCP was implemented and RT capacity was increased, but they still seem to be lower than optimal levels.« less
Hodgkin Lymphoma: Diagnosis and Treatment.
Ansell, Stephen M
2015-11-01
Hodgkin lymphoma is a rare B-cell malignant neoplasm affecting approximately 9000 new patients annually. This disease represents approximately 11% of all lymphomas seen in the United States and comprises 2 discrete disease entities--classical Hodgkin lymphoma and nodular lymphocyte-predominant Hodgkin lymphoma. Within the subcategorization of classical Hodgkin lymphoma are defined subgroups: nodular sclerosis, mixed cellularity, lymphocyte depletion, and lymphocyte-rich Hodgkin lymphoma. Staging of this disease is essential for the choice of optimal therapy. Prognostic models to identify patients at high or low risk for recurrence have been developed, and these models, along with positron emission tomography, are used to provide optimal therapy. The initial treatment for patients with Hodgkin lymphoma is based on the histologic characteristics of the disease, the stage at presentation, and the presence or absence of prognostic factors associated with poor outcome. Patients with early-stage Hodgkin lymphoma commonly receive combined-modality therapies that include abbreviated courses of chemotherapy followed by involved-field radiation treatment. In contrast, patients with advanced-stage Hodgkin lymphoma commonly receive a more prolonged course of combination chemotherapy, with radiation therapy used only in selected cases. For patients with relapse or refractory disease, salvage chemotherapy followed by high-dose treatment and an autologous stem cell transplant is the standard of care. For patients who are ineligible for this therapy or those in whom high-dose therapy and autologous stem cell transplant have failed, treatment with brentuximab vedotin is a standard approach. Additional options include palliative chemotherapy, immune checkpoint inhibitors, nonmyeloablative allogeneic stem cell transplant, or participation in a clinical trial testing novel agents. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Shaverdian, Narek; Yoo, Sun Mi; Cook, Ryan; Chang, Eric M; Jiang, Naomi; Yuan, Ye; Sandler, Kiri; Steinberg, Michael; Lee, Percy
2017-08-01
Internists and primary care providers play a growing role in cancer care. We therefore evaluated the awareness of radiation therapy in general and specifically the clinical utility of stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (NSCLC) among current US internal medicine residents. A web-based institutional review board-approved multi-institutional survey was distributed to US internal medicine residency programs. The survey evaluated trainee demographic characteristics, baseline radiation oncology awareness, knowledge of the role of SBRT for early-stage NSCLC, and whether the survey successfully improved awareness. Thirty US internal medicine programs participated, with an overall participant response rate of 46% (1177 of 2551). Of the trainees, 93% (n=1076) reported no radiation oncology education in their residency, 39% (n=452) reported confidence in knowing when to consult radiation oncology in an oncologic emergency, and 26% (n=293) reported confidence in knowing when to consult radiation oncology in the setting of a newly diagnosed cancer. Of the participants, 76% (n=850) correctly identified that surgical resection is the standard treatment in operable early-stage NSCLC, but only 50% (n=559) of participants would recommend SBRT to a medically inoperable patient, followed by 31% of participants (n=347) who were unsure of the most appropriate treatment, and 10% (n=117) who recommended waiting to offer palliative therapy. Ninety percent of participants (n=1029) agreed that they would benefit from further training on when to consult radiation oncology. Overall, 96% (n=1072) indicated that the survey increased their knowledge and awareness of the role of SBRT. The majority of participating trainees received no education in radiation oncology in their residency, reported a lack of confidence regarding when to consult radiation oncology, and overwhelmingly agreed that they would benefit from further training. These findings should serve as a call to increase the educational collaboration between internal medicine and radiation oncology departments to ensure optimal cancer care. Copyright © 2017 Elsevier Inc. All rights reserved.
Glaser, Adam K; Zhang, Rongxiao; Gladstone, David J; Pogue, Brian W
2014-07-21
Recent studies have proposed that light emitted by the Cherenkov effect may be used for a number of radiation therapy dosimetry applications. There is a correlation between the captured light and expected dose under certain conditions, yet discrepancies have also been observed and a complete examination of the theoretical differences has not been done. In this study, a fundamental comparison between the Cherenkov emission and absorbed dose was explored for x-ray photons, electrons, and protons using both a theoretical and Monte Carlo-based analysis. Based on the findings of where dose correlates with Cherenkov emission, it was concluded that for x-ray photons the light emission would be optimally suited for narrow beam stereotactic radiation therapy and surgery validation studies, for verification of dynamic intensity-modulated and volumetric modulated arc therapy treatment plans in water tanks, near monoenergetic sources (e.g., Co-60 and brachy therapy sources) and also for entrance and exit surface imaging dosimetry of both narrow and broad beams. For electron use, Cherenkov emission was found to be only suitable for surface dosimetry applications. Finally, for proton dosimetry, there exists a fundamental lack of Cherenkov emission at the Bragg peak, making the technique of little use, although post-irradiation detection of light emission from radioisotopes could prove to be useful.
Squamous carcinoma of the vagina: treatment, complications, and long-term follow-up
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rubin, S.C.; Young, J.; Mikuta, J.J.
1985-03-01
Seventy-five cases of primary squamous cell carcinoma of the vagina treated at the University of Pennsylvania are reviewed with long-term follow-up presented. These comprised 2.5% of all female genital malignancies treated during 1958 to 1980 inclusive. Patients treated during that time with non-squamous cell cancers have been excluded. Patients are analyzed with regard to stage, therapy, complications, and survival. Sixty-five percent of patients were stage I or II. Five-year survival for the entire group was 45%. Patients treated with radical surgery other than exenteration did well, with 7 of 8 surviving 5 years. Serious treatment complications were mostly related tomore » radiation therapy and primarily involved the bowel and bladder. Three patients died of complications. Recurrence carried a grave prognosis as 30 of 33 patients with recurrence died of disease. Most recurrences were diagnosed within the first year following treatment. Patients with advanced disease were more likely to have distant recurrences. Although radiation therapy is generally the treatment of choice, radical surgery can yield excellent results when used in carefully selected patients. With meticulous attention to radiation dosage and technique it is hoped that treatment morbidity can be reduced. Optimal treatment of advanced disease may require some form of adjuvant systemic therapy.« less
Rivest-Hénault, David; Dowson, Nicholas; Greer, Peter B; Fripp, Jurgen; Dowling, Jason A
2015-07-01
CT-MR registration is a critical component of many radiation oncology protocols. In prostate external beam radiation therapy, it allows the propagation of MR-derived contours to reference CT images at the planning stage, and it enables dose mapping during dosimetry studies. The use of carefully registered CT-MR atlases allows the estimation of patient specific electron density maps from MRI scans, enabling MRI-alone radiation therapy planning and treatment adaptation. In all cases, the precision and accuracy achieved by registration influences the quality of the entire process. Most current registration algorithms do not robustly generalize and lack inverse-consistency, increasing the risk of human error and acting as a source of bias in studies where information is propagated in a particular direction, e.g. CT to MR or vice versa. In MRI-based treatment planning where both CT and MR scans serve as spatial references, inverse-consistency is critical, if under-acknowledged. A robust, inverse-consistent, rigid/affine registration algorithm that is well suited to CT-MR alignment in prostate radiation therapy is presented. The presented method is based on a robust block-matching optimization process that utilises a half-way space definition to maintain inverse-consistency. Inverse-consistency substantially reduces the influence of the order of input images, simplifying analysis, and increasing robustness. An open source implementation is available online at http://aehrc.github.io/Mirorr/. Experimental results on a challenging 35 CT-MR pelvis dataset demonstrate that the proposed method is more accurate than other popular registration packages and is at least as accurate as the state of the art, while being more robust and having an order of magnitude higher inverse-consistency than competing approaches. The presented results demonstrate that the proposed registration algorithm is readily applicable to prostate radiation therapy planning. Copyright © 2015. Published by Elsevier B.V.
Wang, Huan; Dong, Peng; Liu, Hongcheng; Xing, Lei
2017-02-01
Current treatment planning remains a costly and labor intensive procedure and requires multiple trial-and-error adjustments of system parameters such as the weighting factors and prescriptions. The purpose of this work is to develop an autonomous treatment planning strategy with effective use of prior knowledge and in a clinically realistic treatment planning platform to facilitate radiation therapy workflow. Our technique consists of three major components: (i) a clinical treatment planning system (TPS); (ii) a formulation of decision-function constructed using an assemble of prior treatment plans; (iii) a plan evaluator or decision-function and an outer-loop optimization independent of the clinical TPS to assess the TPS-generated plan and to drive the search toward a solution optimizing the decision-function. Microsoft (MS) Visual Studio Coded UI is applied to record some common planner-TPS interactions as subroutines for querying and interacting with the TPS. These subroutines are called back in the outer-loop optimization program to navigate the plan selection process through the solution space iteratively. The utility of the approach is demonstrated by using clinical prostate and head-and-neck cases. An autonomous treatment planning technique with effective use of an assemble of prior treatment plans is developed to automatically maneuver the clinical treatment planning process in the platform of a commercial TPS. The process mimics the decision-making process of a human planner and provides a clinically sensible treatment plan automatically, thus reducing/eliminating the tedious manual trial-and-errors of treatment planning. It is found that the prostate and head-and-neck treatment plans generated using the approach compare favorably with that used for the patients' actual treatments. Clinical inverse treatment planning process can be automated effectively with the guidance of an assemble of prior treatment plans. The approach has the potential to significantly improve the radiation therapy workflow. © 2016 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Brahme, Anders; Lind, Bengt K.
2002-04-01
Radiation therapy is today in a state of very rapid development with new intensity modulated treatment techniques continuously being developed. This has made intensity modulated electron and photon beams almost as powerful as conventional uniform beam proton therapy. To be able to cure also the most advanced hypoxic and radiation resistant tumors of complex local spread, intensity modulated light ion beams are really the ultimate tool and only slightly more expensive than proton therapy. The aim of the new center for ion therapy and tumor diagnostics in Stockholm is to develop radiobiologically optimized 3-dimensional pencil beam scanning techniques. Beside the "classical" approaches using low ionization density hydrogen ions (protons, but also deuterons and tritium nuclei) and high ionization density carbon ions, two new approaches will be developed. In the first one lithium or beryllium ions, that induce the least detrimental biological effect to normal tissues for a given biological effect in a small volume of the tumor, will be key particles. In the second approach, referred patients will be given a high-dose high-precision "boost" treatment with carbon or oxygen ions during one week preceding the final treatment with conventional radiations in the referring hospital. The rationale behind these approaches is to reduce the high ionization density dose to the normal tissue stroma inside the tumor and to ensure a microscopically uniform dose delivery. The principal idea of the center is to closely integrate ion therapy into the clinical routine and research of a large radiotherapy department. The light ion therapy center will therefore be combined with advanced tumor diagnostics including MR and PET-CT imaging to facilitate efficient high-precision high-dose boost treatment of remitted patients. The possibility to do 3D tumor diagnostics and 3D dose delivery verification with the same PET camera will be the ultimate step in high quality adaptive radiation therapy where alterations in the delivered dose can be corrected by subsequent treatments
Coverage-based constraints for IMRT optimization
NASA Astrophysics Data System (ADS)
Mescher, H.; Ulrich, S.; Bangert, M.
2017-09-01
Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is possible to account for uncertainties by explicit minimization of objectives that describe worst-case treatment scenarios, the expectation value of the treatment or the coverage probability of the target volumes during treatment planning. In this note we show that approaches relying on objectives to induce a specific coverage of the clinical target volumes are inevitably sensitive to variation of the relative weighting of the objectives. To address this issue, we introduce coverage-based constraints for intensity-modulated radiation therapy (IMRT) treatment planning. Our implementation follows the concept of coverage-optimized planning that considers explicit error scenarios to calculate and optimize patient-specific probabilities q(\\hat{d}, \\hat{v}) of covering a specific target volume fraction \\hat{v} with a certain dose \\hat{d} . Using a constraint-based reformulation of coverage-based objectives we eliminate the trade-off between coverage and competing objectives during treatment planning. In-depth convergence tests including 324 treatment plan optimizations demonstrate the reliability of coverage-based constraints for varying levels of probability, dose and volume. General clinical applicability of coverage-based constraints is demonstrated for two cases. A sensitivity analysis regarding penalty variations within this planing study based on IMRT treatment planning using (1) coverage-based constraints, (2) coverage-based objectives, (3) probabilistic optimization, (4) robust optimization and (5) conventional margins illustrates the potential benefit of coverage-based constraints that do not require tedious adjustment of target volume objectives.
Anesthesia Practice in Pediatric Radiation Oncology: Mayo Clinic Arizona's Experience 2014-2016.
Khurmi, Narjeet; Patel, Perene; Koushik, Sarang; Daniels, Thomas; Kraus, Molly
2018-02-01
Understanding the goals of targeted radiation therapy in pediatrics is critical to developing high quality and safe anesthetic plans in this patient population. An ideal anesthetic plan includes allaying anxiety and achieving optimal immobilization, while ensuring rapid and efficient recovery. We conducted a retrospective chart review of children receiving anesthesia for radiation oncology procedures from 1/1/2014 to 7/31/2016. No anesthetics were excluded from the analysis. The electronic anesthesia records were analyzed for perianesthetic complications along with efficiency data. To compare our results to past and current data, we identified relevant medical literature covering a period from 1984-2017. A total of 997 anesthetic procedures were delivered in 58 unique patients. The vast majority of anesthetics were single-agent anesthesia with propofol. The average duration of radiation treatment was 13.24 min. The average duration of anesthesia was 37.81 min, and the average duration to meet discharge criteria in the recovery room was 29.50 min. There were seven instances of perianesthetic complications (0.7%) and no complications noted for the 80 CT simulations. Two of the seven complications occurred in patients receiving total body irradiation. The 5-year survival rate for pediatric cancers has improved greatly in part due to more effective and targeted radiation therapy. Providing an anesthetic with minimal complications is critical for successful daily radiation treatment. The results of our data analysis corroborate other contemporary studies showing minimal risk to patients undergoing radiation therapy under general anesthesia with propofol. Our data reveal that single-agent anesthesia with propofol administered by a dedicated anesthesia team is safe and efficient and should be considered for patients requiring multiple radiation treatments under anesthesia.
Zhang, H H; Gao, S; Chen, W; Shi, L; D'Souza, W D; Meyer, R R
2013-03-21
An important element of radiation treatment planning for cancer therapy is the selection of beam angles (out of all possible coplanar and non-coplanar angles in relation to the patient) in order to maximize the delivery of radiation to the tumor site and minimize radiation damage to nearby organs-at-risk. This category of combinatorial optimization problem is particularly difficult because direct evaluation of the quality of treatment corresponding to any proposed selection of beams requires the solution of a large-scale dose optimization problem involving many thousands of variables that represent doses delivered to volume elements (voxels) in the patient. However, if the quality of angle sets can be accurately estimated without expensive computation, a large number of angle sets can be considered, increasing the likelihood of identifying a very high quality set. Using a computationally efficient surrogate beam set evaluation procedure based on single-beam data extracted from plans employing equallyspaced beams (eplans), we have developed a global search metaheuristic process based on the nested partitions framework for this combinatorial optimization problem. The surrogate scoring mechanism allows us to assess thousands of beam set samples within a clinically acceptable time frame. Tests on difficult clinical cases demonstrate that the beam sets obtained via our method are of superior quality.
Zhang, H H; Gao, S; Chen, W; Shi, L; D’Souza, W D; Meyer, R R
2013-01-01
An important element of radiation treatment planning for cancer therapy is the selection of beam angles (out of all possible coplanar and non-coplanar angles in relation to the patient) in order to maximize the delivery of radiation to the tumor site and minimize radiation damage to nearby organs-at-risk. This category of combinatorial optimization problem is particularly difficult because direct evaluation of the quality of treatment corresponding to any proposed selection of beams requires the solution of a large-scale dose optimization problem involving many thousands of variables that represent doses delivered to volume elements (voxels) in the patient. However, if the quality of angle sets can be accurately estimated without expensive computation, a large number of angle sets can be considered, increasing the likelihood of identifying a very high quality set. Using a computationally efficient surrogate beam set evaluation procedure based on single-beam data extracted from plans employing equally-spaced beams (eplans), we have developed a global search metaheuristic process based on the Nested Partitions framework for this combinatorial optimization problem. The surrogate scoring mechanism allows us to assess thousands of beam set samples within a clinically acceptable time frame. Tests on difficult clinical cases demonstrate that the beam sets obtained via our method are superior quality. PMID:23459411
Standardizing Naming Conventions in Radiation Oncology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santanam, Lakshmi; Hurkmans, Coen; Mutic, Sasa
2012-07-15
Purpose: The aim of this study was to report on the development of a standardized target and organ-at-risk naming convention for use in radiation therapy and to present the nomenclature for structure naming for interinstitutional data sharing, clinical trial repositories, integrated multi-institutional collaborative databases, and quality control centers. This taxonomy should also enable improved plan benchmarking between clinical institutions and vendors and facilitation of automated treatment plan quality control. Materials and Methods: The Advanced Technology Consortium, Washington University in St. Louis, Radiation Therapy Oncology Group, Dutch Radiation Oncology Society, and the Clinical Trials RT QA Harmonization Group collaborated in creatingmore » this new naming convention. The International Commission on Radiation Units and Measurements guidelines have been used to create standardized nomenclature for target volumes (clinical target volume, internal target volume, planning target volume, etc.), organs at risk, and planning organ-at-risk volumes in radiation therapy. The nomenclature also includes rules for specifying laterality and margins for various structures. The naming rules distinguish tumor and nodal planning target volumes, with correspondence to their respective tumor/nodal clinical target volumes. It also provides rules for basic structure naming, as well as an option for more detailed names. Names of nonstandard structures used mainly for plan optimization or evaluation (rings, islands of dose avoidance, islands where additional dose is needed [dose painting]) are identified separately. Results: In addition to its use in 16 ongoing Radiation Therapy Oncology Group advanced technology clinical trial protocols and several new European Organization for Research and Treatment of Cancer protocols, a pilot version of this naming convention has been evaluated using patient data sets with varying treatment sites. All structures in these data sets were satisfactorily identified using this nomenclature. Conclusions: Use of standardized naming conventions is important to facilitate comparison of dosimetry across patient datasets. The guidelines presented here will facilitate international acceptance across a wide range of efforts, including groups organizing clinical trials, Radiation Oncology Institute, Dutch Radiation Oncology Society, Integrating the Healthcare Enterprise, Radiation Oncology domain (IHE-RO), and Digital Imaging and Communication in Medicine (DICOM).« less
Nanoparticle augmented radiation treatment decreases cancer cell proliferation.
Townley, Helen E; Rapa, Elizabeth; Wakefield, Gareth; Dobson, Peter J
2012-05-01
We report significant and controlled cell death using novel x-ray-activatable titania nanoparticles (NPs) doped with lanthanides. Preferential incorporation of such materials into tumor tissue can enhance the effect of radiation therapy. Herein, the incorporation of gadolinium into the NPs is designed to optimize localized energy absorption from a conventional medical x-ray. This result is further optimized by the addition of other rare earth elements. Upon irradiation, energy is transferred to the titania crystal structure, resulting in the generation of reactive oxygen species (ROS). The authors report significant and controlled cell death using x-ray-activated titania nanoparticles doped with lanthanides as enhancers. Upon irradiation X-ray energy is transferred to the titania crystal structure, resulting in the generation of reactive oxygen species. Copyright © 2012 Elsevier Inc. All rights reserved.
Definitive radiation therapy for squamous cell carcinoma of the vagina
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frank, Steven J.; Jhingran, Anuja; Levenback, Charles
2005-05-01
Purpose: To evaluate outcome and describe clinical treatment guidelines for patients with primary squamous cell carcinoma of the vagina treated with definitive radiation therapy. Methods and Materials: Between 1970 and 2000, a total of 193 patients were treated with definitive radiation therapy for squamous cell carcinoma of the vagina at The University of Texas M. D. Anderson Cancer Center. The patients' medical records were reviewed to obtain information about patient, tumor, and treatment characteristics, as well as outcome and patterns of recurrence. Surviving patients were followed for a median of 137 months. Survival rates were calculated using the Kaplan-Meier method,more » with differences assessed using log-rank tests. Results: Disease-specific survival (DSS) and pelvic disease control rates correlated with International Federation of Gynecology and Obstetrics (FIGO) stage and tumor size. At 5 years, DSS rates were 85% for the 50 patients with Stage I, 78% for the 97 patients with Stage II, and 58% for the 46 patients with Stage III-IVA disease (p = 0.0013). Five-year DSS rates were 82% and 60% for patients with tumors {<=}4 cm or >4 cm, respectively (p = 0.0001). At 5 years, pelvic disease control rates were 86% for Stage I, 84% for Stage II, and 71% for Stage III-IVA (p = 0.027). The predominant mode of relapse after definitive radiation therapy was local-regional (68% and 83%, respectively, for patients with stages I-II or III-IVA disease). The incidence of major complications was correlated with FIGO stage; at 5 years, the rates of major complications were 4% for Stage I, 9% for Stage II, and 21% for Stage III-IVA (p < 0.01). Conclusions: Excellent outcomes can be achieved with definitive radiation therapy for invasive squamous cell carcinoma of the vagina. However, to achieve these results, treatment must be individualized according to the site and size of the tumor at presentation and the response to initial external-beam radiation therapy. Brachytherapy plays an important role in the treatment of many vaginal cancers but should be carefully selected and applied to obtain optimal coverage of the target volume.« less
Chen, A Y; Liu, Y-W H; Sheu, R J
2008-01-01
This study investigates the radiation shielding design of the treatment room for boron neutron capture therapy at Tsing Hua Open-pool Reactor using "TORT-coupled MCNP" method. With this method, the computational efficiency is improved significantly by two to three orders of magnitude compared to the analog Monte Carlo MCNP calculation. This makes the calculation feasible using a single CPU in less than 1 day. Further optimization of the photon weight windows leads to additional 50-75% improvement in the overall computational efficiency.
Fang, Dongdong; Shang, Sixia; Liu, Younan; Bakkar, Mohammed; Sumita, Yoshinori; Seuntjens, Jan; Tran, Simon D
2018-02-01
Injections of bone marrow (BM) cell extract, known as 'BM soup', were previously reported to mitigate ionizing radiation (IR) injury to salivary glands (SGs). However, the optimal starting time and frequency to maintain BM soup therapeutic efficacy remains unknown. This study tested the optimal starting time and frequency of BM soup injections in mice radiated with either a single dose or a fractionated dose. First, BM soup treatment was started at 1, 3 or 7 weeks post-IR; positive (non-IR) and negative (IR) control mice received injections of saline (vehicle control). Second, BM soup-treated mice received injections at different frequencies (1, 2, 3 and 5 weekly injections). Third, a 'fractionated-dose radiation' model to injure mouse SGs was developed (5 Gy × 5 days) and compared with the single high dose radiation model. All mice (n = 65) were followed for 16 weeks post-IR. The results showed that starting injections of BM soup between 1 and 3 weeks mitigated the effect of IR-induced injury to SGs and improved the restoration of salivary function. Although the therapeutic effect of BM soup lessens after 8 weeks, it can be sustained by increasing the frequency of weekly injections. Moreover, both single-dose and fractionated-dose radiation models are efficient and comparable in inducing SG injury and BM soup treatments are effective in restoring salivary function in both radiation models. In conclusion, starting injections of BM soup within 3 weeks post-radiation, with 5 weekly injections, maintains 90-100% of saliva flow in radiated mice. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Arbor, Nicolas; Higueret, Stephane; Husson, Daniel
2018-04-01
The CMOS sensor AlphaRad has been designed at the IPHC Strasbourg for real-time monitoring of fast and thermal neutrons over a full energy spectrum. Completely integrated, highly transparent to photons and optimized for low power consumption, this sensor offers very interesting characteristics for the study of internal neutrons in radiation therapy with anthropomorphic phantoms. However, specific effects related to the CMOS metal substructure and to the charge collection process of low energy particles must be carefully estimated before being used for medical applications. We present a detailed characterization of the AlphaRad chip in the MeV energy range using proton and alpha micro-beam experiments performed at the AIFIRA facility (CENBG, Bordeaux). Two-dimensional maps of the charge collection were carried out on a micro-metric scale to be integrated into a Geant4 Monte Carlo simulation of the system. The gamma rejection, as well as the fast and thermal neutrons separation, were studied using both simulation and experimental data. The results highlight the potential of a future system based on CMOS sensor for in-phantom neutron detection in radiation therapies.
Optimal radiotherapy dose schedules under parametric uncertainty
NASA Astrophysics Data System (ADS)
Badri, Hamidreza; Watanabe, Yoichi; Leder, Kevin
2016-01-01
We consider the effects of parameter uncertainty on the optimal radiation schedule in the context of the linear-quadratic model. Our interest arises from the observation that if inter-patient variability in normal and tumor tissue radiosensitivity or sparing factor of the organs-at-risk (OAR) are not accounted for during radiation scheduling, the performance of the therapy may be strongly degraded or the OAR may receive a substantially larger dose than the allowable threshold. This paper proposes a stochastic radiation scheduling concept to incorporate inter-patient variability into the scheduling optimization problem. Our method is based on a probabilistic approach, where the model parameters are given by a set of random variables. Our probabilistic formulation ensures that our constraints are satisfied with a given probability, and that our objective function achieves a desired level with a stated probability. We used a variable transformation to reduce the resulting optimization problem to two dimensions. We showed that the optimal solution lies on the boundary of the feasible region and we implemented a branch and bound algorithm to find the global optimal solution. We demonstrated how the configuration of optimal schedules in the presence of uncertainty compares to optimal schedules in the absence of uncertainty (conventional schedule). We observed that in order to protect against the possibility of the model parameters falling into a region where the conventional schedule is no longer feasible, it is required to avoid extremal solutions, i.e. a single large dose or very large total dose delivered over a long period. Finally, we performed numerical experiments in the setting of head and neck tumors including several normal tissues to reveal the effect of parameter uncertainty on optimal schedules and to evaluate the sensitivity of the solutions to the choice of key model parameters.
Measurement profiles of nano-scale ion beam for optimized radiation energy losses
NASA Astrophysics Data System (ADS)
Woo, T. H.; Cho, H. S.
2011-10-01
The behavior of charged particles is investigated for nano-scale ion beam therapy using a medical accelerator. Computational work is performed for the Bragg-peak simulation, which is focused on human organ material of pancreas and thyroid. The Results show that the trends of the dose have several different kinds of distributions. Before constructing a heavy ion collider, this study can give us the reliability of the therapeutic effect. Realistic treatment using human organs is calculated in a simple and cost effective manner using the computational code, the Stopping and Range of Ions in Matter 2008 (SRIM 2008). Considering the safety of the therapy, it is suggested to give a patient orient planning of the cancer therapy. The energy losses in ionization and phonon are analyzed, which are the behaviors in the molecular level nano-scopic investigation. The different fluctuations are shown at 150 MeV, where the lowest temperature is found in proton and pancreas case. Finally, the protocol for the radiation therapy is constructed by the simulation in which the procedure for a better therapy is selected. An experimental measurement incorporated with the simulations could be programmed by this protocol.
NASA Astrophysics Data System (ADS)
Yarmand, Hamed; Winey, Brian; Craft, David
2013-09-01
Stereotactic body radiation therapy (SBRT) is characterized by delivering a high amount of dose in a short period of time. In SBRT the dose is delivered using open fields (e.g., beam’s-eye-view) known as ‘apertures’. Mathematical methods can be used for optimizing treatment planning for delivery of sufficient dose to the cancerous cells while keeping the dose to surrounding organs at risk (OARs) minimal. Two important elements of a treatment plan are quality and delivery time. Quality of a plan is measured based on the target coverage and dose to OARs. Delivery time heavily depends on the number of beams used in the plan as the setup times for different beam directions constitute a large portion of the delivery time. Therefore the ideal plan, in which all potential beams can be used, will be associated with a long impractical delivery time. We use the dose to OARs in the ideal plan to find the plan with the minimum number of beams which is guaranteed to be epsilon-optimal (i.e., a predetermined maximum deviation from the ideal plan is guaranteed). Since the treatment plan optimization is inherently a multi-criteria-optimization problem, the planner can navigate the ideal dose distribution Pareto surface and select a plan of desired target coverage versus OARs sparing, and then use the proposed technique to reduce the number of beams while guaranteeing epsilon-optimality. We use mixed integer programming (MIP) for optimization. To reduce the computation time for the resultant MIP, we use two heuristics: a beam elimination scheme and a family of heuristic cuts, known as ‘neighbor cuts’, based on the concept of ‘adjacent beams’. We show the effectiveness of the proposed technique on two clinical cases, a liver and a lung case. Based on our technique we propose an algorithm for fast generation of epsilon-optimal plans.
NASA Astrophysics Data System (ADS)
Hagan, Aaron; Sawant, Amit; Folkerts, Michael; Modiri, Arezoo
2018-01-01
We report on the design, implementation and characterization of a multi-graphic processing unit (GPU) computational platform for higher-order optimization in radiotherapy treatment planning. In collaboration with a commercial vendor (Varian Medical Systems, Palo Alto, CA), a research prototype GPU-enabled Eclipse (V13.6) workstation was configured. The hardware consisted of dual 8-core Xeon processors, 256 GB RAM and four NVIDIA Tesla K80 general purpose GPUs. We demonstrate the utility of this platform for large radiotherapy optimization problems through the development and characterization of a parallelized particle swarm optimization (PSO) four dimensional (4D) intensity modulated radiation therapy (IMRT) technique. The PSO engine was coupled to the Eclipse treatment planning system via a vendor-provided scripting interface. Specific challenges addressed in this implementation were (i) data management and (ii) non-uniform memory access (NUMA). For the former, we alternated between parameters over which the computation process was parallelized. For the latter, we reduced the amount of data required to be transferred over the NUMA bridge. The datasets examined in this study were approximately 300 GB in size, including 4D computed tomography images, anatomical structure contours and dose deposition matrices. For evaluation, we created a 4D-IMRT treatment plan for one lung cancer patient and analyzed computation speed while varying several parameters (number of respiratory phases, GPUs, PSO particles, and data matrix sizes). The optimized 4D-IMRT plan enhanced sparing of organs at risk by an average reduction of 26% in maximum dose, compared to the clinical optimized IMRT plan, where the internal target volume was used. We validated our computation time analyses in two additional cases. The computation speed in our implementation did not monotonically increase with the number of GPUs. The optimal number of GPUs (five, in our study) is directly related to the hardware specifications. The optimization process took 35 min using 50 PSO particles, 25 iterations and 5 GPUs.
Hagan, Aaron; Sawant, Amit; Folkerts, Michael; Modiri, Arezoo
2018-01-16
We report on the design, implementation and characterization of a multi-graphic processing unit (GPU) computational platform for higher-order optimization in radiotherapy treatment planning. In collaboration with a commercial vendor (Varian Medical Systems, Palo Alto, CA), a research prototype GPU-enabled Eclipse (V13.6) workstation was configured. The hardware consisted of dual 8-core Xeon processors, 256 GB RAM and four NVIDIA Tesla K80 general purpose GPUs. We demonstrate the utility of this platform for large radiotherapy optimization problems through the development and characterization of a parallelized particle swarm optimization (PSO) four dimensional (4D) intensity modulated radiation therapy (IMRT) technique. The PSO engine was coupled to the Eclipse treatment planning system via a vendor-provided scripting interface. Specific challenges addressed in this implementation were (i) data management and (ii) non-uniform memory access (NUMA). For the former, we alternated between parameters over which the computation process was parallelized. For the latter, we reduced the amount of data required to be transferred over the NUMA bridge. The datasets examined in this study were approximately 300 GB in size, including 4D computed tomography images, anatomical structure contours and dose deposition matrices. For evaluation, we created a 4D-IMRT treatment plan for one lung cancer patient and analyzed computation speed while varying several parameters (number of respiratory phases, GPUs, PSO particles, and data matrix sizes). The optimized 4D-IMRT plan enhanced sparing of organs at risk by an average reduction of [Formula: see text] in maximum dose, compared to the clinical optimized IMRT plan, where the internal target volume was used. We validated our computation time analyses in two additional cases. The computation speed in our implementation did not monotonically increase with the number of GPUs. The optimal number of GPUs (five, in our study) is directly related to the hardware specifications. The optimization process took 35 min using 50 PSO particles, 25 iterations and 5 GPUs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Changhoon; Hong, Beom-Ju; Bok, Seoyeon
Purpose: To investigate the serial changes of tumor hypoxia in response to single high-dose irradiation by various clinical and preclinical methods to propose an optimal fractionation schedule for stereotactic ablative radiation therapy. Methods and Materials: Syngeneic Lewis lung carcinomas were grown either orthotopically or subcutaneously in C57BL/6 mice and irradiated with a single dose of 15 Gy to mimic stereotactic ablative radiation therapy used in the clinic. Serial [{sup 18}F]-misonidazole (F-MISO) positron emission tomography (PET) imaging, pimonidazole fluorescence-activated cell sorting analyses, hypoxia-responsive element-driven bioluminescence, and Hoechst 33342 perfusion were performed before irradiation (day −1), at 6 hours (day 0), and 2 (daymore » 2) and 6 (day 6) days after irradiation for both subcutaneous and orthotopic lung tumors. For F-MISO, the tumor/brain ratio was analyzed. Results: Hypoxic signals were too low to quantitate for orthotopic tumors using F-MISO PET or hypoxia-responsive element-driven bioluminescence imaging. In subcutaneous tumors, the maximum tumor/brain ratio was 2.87 ± 0.483 at day −1, 1.67 ± 0.116 at day 0, 2.92 ± 0.334 at day 2, and 2.13 ± 0.385 at day 6, indicating that tumor hypoxia was decreased immediately after irradiation and had returned to the pretreatment levels at day 2, followed by a slight decrease by day 6 after radiation. Pimonidazole analysis also revealed similar patterns. Using Hoechst 33342 vascular perfusion dye, CD31, and cleaved caspase 3 co-immunostaining, we found a rapid and transient vascular collapse, which might have resulted in poor intratumor perfusion of F-MISO PET tracer or pimonidazole delivered at day 0, leading to decreased hypoxic signals at day 0 by PET or pimonidazole analyses. Conclusions: We found tumor hypoxia levels decreased immediately after delivery of a single dose of 15 Gy and had returned to the pretreatment levels 2 days after irradiation and had decreased slightly by day 6. Our results indicate that single high-dose irradiation can produce a rapid, but reversible, vascular collapse in tumors.« less
Nanoparticle-based photodynamic therapy on non-melanoma skin cancer
NASA Astrophysics Data System (ADS)
Fanjul-Vélez, F.; Arce-Diego, J. L.
2018-02-01
There are several advantages of Photodynamic Therapy (PDT) for nonmelanoma skin cancer treatment compared to conventional treatment techniques such as surgery, radiotherapy or chemotherapy. Among these advantages its noninvasive nature, the use of non ionizing radiation and its high selectivity can be mentioned. Despite all these advantages, the therapeutic efficiency of the current clinical protocol is not complete in all the patients and depends on the type of pathology. An adequate dosimetry is needed in order to personalize the protocol. There are strategies that try to overcome the current PDT shortcomings, such as the improvement of the photosensitizer accumulation in the target tissue, optical radiation distribution optimization or photochemical reactions maximization. These strategies can be further complemented by the use of nanostructures with conventional PDT. Customized dosimetry for nanoparticle-based PDT requires models in order to adjust parameters of different nature to get an optimal tumor removal. In this work, a predictive model of nanoparticle-based PDT is proposed and analyzed. Dosimetry in nanoparticle-based PDT is going to be influenced by photosensitizer-nanoparticle distribution in the malignant tissue, its influence in the optical radiation distribution and the subsequent photochemical reactions. Nanoparticles are considered as photosensitizer carriers on several types of non-melanoma skin cancer. Shielding effects are taken into account. The results allow to compare the estimated treatment outcome with and without nanoparticles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herschtal, Alan, E-mail: Alan.Herschtal@petermac.org; Faculty of Health, Arts and Design, Swinburne University of Technology, Melbourne; Te Marvelde, Luc
Objective: To develop a mathematical tool that can update a patient's planning target volume (PTV) partway through a course of radiation therapy to more precisely target the tumor for the remainder of treatment and reduce dose to surrounding healthy tissue. Methods and Materials: Daily on-board imaging was used to collect large datasets of displacements for patients undergoing external beam radiation therapy for solid tumors. Bayesian statistical modeling of these geometric uncertainties was used to optimally trade off between displacement data collected from previously treated patients and the progressively accumulating data from a patient currently partway through treatment, to optimally predictmore » future displacements for that patient. These predictions were used to update the PTV position and margin width for the remainder of treatment, such that the clinical target volume (CTV) was more precisely targeted. Results: Software simulation of dose to CTV and normal tissue for 2 real prostate displacement datasets consisting of 146 and 290 patients treated with a minimum of 30 fractions each showed that re-evaluating the PTV position and margin width after 8 treatment fractions reduced healthy tissue dose by 19% and 17%, respectively, while maintaining CTV dose. Conclusion: Incorporating patient-specific displacement patterns from early in a course of treatment allows PTV adaptation for the remainder of treatment. This substantially reduces the dose to healthy tissues and thus can reduce radiation therapy–induced toxicities, improving patient outcomes.« less
Beaton, Lindsay A; Ferrarotto, Catherine; Marro, Leonora; Samiee, Sara; Malone, Shawn; Grimes, Scott; Malone, Kyle; Wilkins, Ruth C
2013-04-01
In vitro irradiated blood samples from prostate cancer patients showing late normal tissue damage were examined for lymphocyte response by measuring chromosomal aberrations and proliferation rate. Patients were selected from a randomized trial evaluating the optimal timing of dose-escalated radiation and short-course androgen deprivation therapy. Of 438 patients, 3% experienced grade 3 late radiation proctitis and were considered to be radiosensitive. Blood samples were taken from 10 of these patients along with 20 matched samples from patients with grade 0 proctitis. The samples were irradiated at 6 Gy and, along with control samples, were analyzed for dicentric chromosomes and excess fragments per cell. Cells in first and second metaphase were also enumerated to determine the lymphocyte proliferation rate. At 6 Gy, there were statistically significant differences between the radiosensitive and control cohorts for 3 endpoints: the mean number of dicentric chromosomes per cell (3.26 ± 0.31, 2.91 ± 0.32; P=.0258), the mean number of excess fragments per cell (2.27 ± 0.23, 1.43 ± 0.37; P<.0001), and the proportion of cells in second metaphase (0.27 ± 0.10, 0.46 ± 0.09; P=.0007). These results may be a valuable indicator for identifying radiosensitive patients and for tailoring radiation therapy. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zasneda, Sabriani; Widita, Rena
2010-06-22
Boron Neutron Capture Therapy (BNCT) is a cancer therapy by utilizing thermal neutron to produce alpha particles and lithium nuclei. The superiority of BNCT is that the radiation effects could be limited only for the tumor cells. BNCT radiation dose depends on the distribution of boron in the tumor. Absorbed dose to the cells from the reaction 10B (n, {alpha}) 7Li was calculated near interface medium containing boron and boron-free region. The method considers the contribution of the alpha particle and recoiled lithium particle to the absorbed dose and the variation of Linear Energy Transfer (LET) charged particles energy. Geometricalmore » factor data of boron distribution for the spherical surface is used to calculate the energy absorbed in the tumor cells, brain and scalp for case Glioblastoma Multiforme. The result shows that the optimal dose in tumor is obtained for boron concentrations of 22.1 mg {sup 10}B/g blood.« less
Head and Neck Cancer Patients – Information for the General Dental Practitioner.
Noone, Jennifer; Barclay, Craig
2017-03-01
Salivary gland damage is the most common adverse effect associated with radiation therapy to the head and neck. A combination of hyposalivation and dietary changes, with a reduced emphasis on oral hygiene practices can contribute to a massive increase in a person’s caries risk status. This can be further complicated by limited mouth opening. To enable optimal dental care for head and neck cancer patients before, during and after radiation therapy, patients must be informed and educated about the potential risks of dental caries and the preventive strategies available. All patients should receive a pre-radiotherapy dental assessment by a Restorative Dentistry Consultant. This information will be delivered to the patient, often at an emotionally charged time, and can be lost amongst all the information related to other aspects of his/her cancer management. General Dental Practitioners (GDPs) are therefore in a pivotal position to reiterate this information post radiation therapy and ensure compliance with preventive strategies, with the overall aim to improve quality of life and avoid the need for future extractions and the resulting risk of osteoradionecrosis. Clinical relevance: This article highlights the GDP’s role in the shared management of head and neck cancer patients who have received radiotherapy as part of their cancer treatment. The critical issue of dental caries, one of the late effects of radiation-induced hyposalivation, will be focused upon. Other side-effects, such as trismus and osteoradionecrosis, will also be discussed. This article aims to supply GDPs with accurate information to provide to their patients with post radiation therapy, whilst highlighting what treatment is within their remit and when it may be appropriate to refer.
NASA Astrophysics Data System (ADS)
Oktaria, Sianne; Corde, Stéphanie; Lerch, Michael L. F.; Konstantinov, Konstantin; Rosenfeld, Anatoly B.; Tehei, Moeava
2015-10-01
Despite the use of multimodal treatments incorporating surgery, chemotherapy and radiotherapy, local control of gliomas remains a major challenge. The potential of a new treatment approach called indirect radio-chemo-beta therapy using the synergy created by combining methotrexate (MTX) with bromodeoxyuridine (BrUdR) under optimum energy x-ray irradiation is assessed. 9L rat gliosarcoma cells pre-treated with 0.01 μM MTX and/or 10 μM BrUdR were irradiated in vitro with 50 kVp, 125 kVp, 250 kVp, 6 MV and 10 MV x-rays. The cytotoxicity was assessed using clonogenic survival as the radiobiological endpoint. The photon energy with maximum effect was determined using radiation sensitization enhancement factors at 10% clonogenic survival (SER10%). The cell cycle distribution was investigated using flow cytometric analysis with propidium iodide staining. Incorporation of BrUdR in the DNA was detected by the fluorescence of labelled anti-BrUdR antibodies. The radiation sensitization enhancement exhibits energy dependence with a maximum of 2.3 at 125 kVp for the combined drug treated cells. At this energy, the shape of the clonogenic survival curve of the pharmacological agents treated cells changes substantially. This change is interpreted as an increased lethality of the local radiation environment and is attributed to supplemented inhibition of DNA repair. Radiation induced chemo-beta therapy was demonstrated in vitro by the targeted activation of combined pharmacological agents with optimized energy tuning of x-ray beams on 9 L cells. Our results show that this is a highly effective form of chemo-radiation therapy.
Shaikh, Talha; Churilla, Thomas M; Monpara, Pooja; Scott, Walter J; Cohen, Steven J; Meyer, Joshua E
There are limited data regarding clinical and treatment factors associated with radiation pneumonitis (RP) in patients receiving taxane-based trimodality therapy for esophageal cancer. The purpose of this study was to identify predictors of RP in patients undergoing trimodality therapy. We retrospectively reviewed patients undergoing chemoradiation followed by esophagectomy between 2006 and 2011. The association between clinical and dosimetric factors with RP was assessed using χ 2 test and Mann-Whitney U test. Multivariable regression was used to assess the relationship between grade 2+ RP and clinical/dosimetric factors. Receiver operator curves were generated to identify threshold doses for RP. A total of 139 patients were included; 19 (13.7%) patients experienced grade 2+ RP. Patients with upper/middle thoracic tumors (P = .038) and receiving higher radiation doses (P = .038) were more likely to develop grade 2+ RP. There was no association between taxane-based therapy and grade 2+ RP (P = .728). The percent volume of lung receiving 5 Gy (V5; P < .001), 10 Gy (P < .001), 20 Gy (V20; P < .001), and 30 Gy (P < .001) was associated with an increased risk of grade 2+ RP. On multivariable regression, the lung V5 (odds ratio, 1.101; 95% confidence interval, 1.1014-1.195) and V20 (odds ratio, 1.149; 95% confidence interval, 1.1015-1.301) remained associated with grade 2+ RP. A V5 ≤65% and V20 ≤25% were identified as optimal thresholds for increased grade 2+ RP. Dosimetric parameters are strong predictors of symptomatic RP in patients undergoing trimodality therapy for esophageal cancer. Mitigating the risk of RP in these patients should be an important consideration during treatment planning. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Matthews, Ellyn E.; Cook, Paul F.
2011-01-01
Objective The impact of diagnosis and treatment for breast cancer, stressors that affect emotional well-being, is influenced by several psychosocial factors and the relationships among them. The purpose of this study was to investigate the relationship between optimism and emotional well-being (EWB) and the individual and combined mediation of this relationship by perceived social support (SS), problem focused coping (PFC), and self-transcendence in women with breast cancer during radiation therapy. Methods Ninety-three women receiving radiation treatment for breast cancer completed questionnaires that measured EWB, optimism, SS, PFC, and self-transcendence. Results Correlational and multiple regression analysis revealed that optimism was positively related to EWB. Of the three mediators, self-transcendence alone was found to partially mediate the relationship between optimism and EWB. The relationship between optimism and PFC was not significant. Optimism was related to SS, but its indirect effect on EWB through SS did not reach significance. Conclusions and implications During breast cancer treatment, the positive effects of optimism on EWB are partially mediated by a woman’s level of self-transcendence. Brief screening of women’s optimism may help identify women at risk for psychological distress. Early detection and interventions to promote psychological adjustment throughout the cancer trajectory (e.g. enhancing self-transcendence) should receive attention in future research. PMID:19034884
Roadmap to Clinical Use of Gold Nanoparticles for Radiation Sensitization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuemann, Jan, E-mail: jschuemann@mgh.harvard.edu; Berbeco, Ross; Chithrani, Devika B.
2016-01-01
The past decade has seen a dramatic increase in interest in the use of gold nanoparticles (GNPs) as radiation sensitizers for radiation therapy. This interest was initially driven by their strong absorption of ionizing radiation and the resulting ability to increase dose deposited within target volumes even at relatively low concentrations. These early observations are supported by extensive experimental validation, showing GNPs' efficacy at sensitizing tumors in both in vitro and in vivo systems to a range of types of ionizing radiation, including kilovoltage and megavoltage X rays as well as charged particles. Despite this experimental validation, there has been limited translationmore » of GNP-mediated radiation sensitization to a clinical setting. One of the key challenges in this area is the wide range of experimental systems that have been investigated, spanning a range of particle sizes, shapes, and preparations. As a result, mechanisms of uptake and radiation sensitization have remained difficult to clearly identify. This has proven a significant impediment to the identification of optimal GNP formulations which strike a balance among their radiation sensitizing properties, their specificity to the tumors, their biocompatibility, and their imageability in vivo. This white paper reviews the current state of knowledge in each of the areas concerning the use of GNPs as radiosensitizers, and outlines the steps which will be required to advance GNP-enhanced radiation therapy from their current pre-clinical setting to clinical trials and eventual routine usage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horiot, Jean-Claude
Nausea and vomiting are two of the most distressing side effects of radiotherapy and cytotoxic drugs, which currently are often combined to treat moderately advanced and advanced solid tumors. Inadequate control of these symptoms may result in significant patient suffering and decrease in the patient's quality of life, which has been shown to decrease patients' compliance to treatment, with potential impact on disease outcome. It is, therefore, important that radiation oncologists recognize the need for adequate prophylactic treatment of radiation-induced nausea and vomiting (RINV) to avoid the detrimental effects on patients' quality of life, and optimize chances for cure. Themore » 5-hydroxytryptamine type 3 (5-HT{sub 3})-receptor antagonists have been proved to provide effective antiemetic therapy in patients undergoing highly emetogenic radiotherapy. Nevertheless, several large surveys have shown that optimal treatments are not always used. Hence, a risk exists that waiting for RINV symptoms rather than prescribing prophylactic antiemetic treatment may lead to increased patient suffering, poorer disease control, and less cost-effective therapy options. Prophylactic management with an effective 5-HT{sub 3}-receptor antagonist should offer a better treatment option for patients at high to moderate risk of RINV. Adequate control of RINV should contribute to patient compliance to treatment, improved therapy outcomes, and decreased burdens on nursing and health care resources.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cormack, R; Ngwa, W; Makrigiorgos, G
Purpose: Permanent prostate brachytherapy spacers can be used to deliver sustained doses of radiosentitizing drug directly to the target, in order to enhance the radiation effect. Implantable nanoplatforms for chemo-radiation therapy (INCeRTs) have a maximum drug capacity and can be engineered to control the drug release schedule. The optimal schedule for sensitization during continuous low dose rate irradiation is unknown. This work studies the optimal release schedule of drug for both traditional sensitizers, and those that work by suppressing DNA repair processes. Methods: Six brachytherapy treatment plans were used to model the anatomy, implant geometry and calculate the spatial distributionmore » of radiation dose and drug concentrations for a range of drug diffusion parameters. Three state partial differential equations (cells healthy, damaged or dead) modeled the effect of continuous radiation (radiosensitivities α,β) and cellular repair (time tr) on a cell population. Radiosensitization was modeled as concentration dependent change in α,β or tr which with variable duration under the constraint of fixed total drug release. Average cell kill was used to measure effectiveness. Sensitization by means of both enhanced damage and reduced repair were studied. Results: Optimal release duration is dependent on the concentration of radiosensitizer compared to the saturation concentration (csat) above which additional sensitization does not occur. Long duration drug release when enhancing α or β maximizes cell death when drug concentrations are generally over csat. Short term release is optimal for concentrations below saturation. Sensitization by suppressing repair has a similar though less distinct trend that is more affected by the radiation dose distribution. Conclusion: Models of sustained local radiosensitization show potential to increase the effectiveness of radiation in permanent prostate brachytherapy. INCeRTs with high drug capacity produce the greatest benefit with drug release over weeks. If in-vivo drug concentrations are not able to approach saturation concentration, durations of days is optimal. DOD 1R21CA16977501; A. David Mazzone Awards Program 2012PD164.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stick, Line B., E-mail: line.bjerregaard.stick@regionh.dk; Niels Bohr Institute, Faculty of Science, University of Copenhagen, Copenhagen; Yu, Jen
Purpose: The study aims to perform joint estimation of the risk of recurrence caused by inadequate radiation dose coverage of lymph node targets and the risk of cardiac toxicity caused by radiation exposure to the heart. Delivered photon plans are compared with realistic proton plans, thereby providing evidence-based estimates of the heterogeneity of treatment effects in consecutive cases for the 2 radiation treatment modalities. Methods and Materials: Forty-one patients referred for postlumpectomy comprehensive nodal photon irradiation for left-sided breast cancer were included. Comparative proton plans were optimized by a spot scanning technique with single-field optimization from 2 en face beams.more » Cardiotoxicity risk was estimated with the model of Darby et al, and risk of recurrence following a compromise of lymph node coverage was estimated by a linear dose-response model fitted to the recurrence data from the recently published EORTC (European Organisation for Research and Treatment of Cancer) 22922/10925 and NCIC-CTG (National Cancer Institute of Canada Clinical Trials Group) MA.20 randomized controlled trials. Results: Excess absolute risk of cardiac morbidity was small with photon therapy at an attained age of 80 years, with median values of 1.0% (range, 0.2%-2.9%) and 0.5% (range, 0.03%-1.0%) with and without cardiac risk factors, respectively, but even lower with proton therapy (0.13% [range, 0.02%-0.5%] and 0.06% [range, 0.004%-0.3%], respectively). The median estimated excess absolute risk of breast cancer recurrence after 10 years was 0.10% (range, 0.0%-0.9%) with photons and 0.02% (range, 0.0%-0.07%) with protons. The association between age of the patient and benefit from proton therapy was weak, almost non-existing (Spearman rank correlations of −0.15 and −0.30 with and without cardiac risk factors, respectively). Conclusions: Modern photon therapy yields limited risk of cardiac toxicity in most patients, but proton therapy can reduce the predicted risk of cardiac toxicity by up to 2.9% and the risk of breast cancer recurrence by 0.9% in individual patients. Predicted benefit correlates weakly with age. Combined assessment of the risk from cardiac exposure and inadequate target coverage is desirable for rational consideration of competing photon and proton therapy plans.« less
Fu, Yuchuan; Deng, Min; Zhou, Xiaojuan; Lin, Qiang; Du, Bin; Tian, Xue; Xu, Yong; Wang, Jin; Lu, You; Gong, Youling
2017-01-01
To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plans were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V 5 , V 13 , V 20 , mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V 30 for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated radiation therapy technique. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jost, Gregor; Mensing, Tristan; Golfier, Sven
2009-06-15
Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detectionmore » system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasi-monochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten K{alpha} emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement factor increases from 2.2 to 2.4 by using quasi-monochromatic instead of polychromatic radiation. An additional increase in the radiation dose by a factor of 1.4 due to the focusing characteristic of the x-ray optical module was calculated. Photoelectric-enhanced radiation therapy based on a clinical CT unit combined with an x-ray optical module is a novel therapy option in radiation oncology. The optimized quasi-monochromatic radiation is strongly focused and ensures high photoelectric dose enhancement for iodine.« less
Wound Healing in PatientsWith Cancer
Payne, Wyatt G.; Naidu, Deepak K.; Wheeler, Chad K.; Barkoe, David; Mentis, Marni; Salas, R. Emerick; Smith, David J.; Robson, Martin C.
2008-01-01
Objective: The treatment of patients with cancer has advanced into a complex, multimodal approach incorporating surgery, radiation, and chemotherapy. Managing wounds in this population is complicated by tumor biology, the patient's disease state, and additional comorbidities, some of which may be iatrogenic. Radiation therapy, frequently employed for local-regional control of disease following surgical resection, has quantifiable negative healing effects due to local tissue fibrosis and vascular effects. Chemotherapeutic agents, either administered alone or as combination therapy with surgery and radiation, may have detrimental effects on the rapidly dividing tissues of healing wounds. Overall nutritional status, often diminished in patients with cancer, is an important aspect to the ability of patients to heal after surgical procedures and/or treatment regimens. Methods: An extensive literature search was performed to gather pertinent information on the topic of wound healing in patients with cancer. The effects that surgical procedures, radiation therapy, chemotherapy, and nutritional deficits play in wound healing in these patients were reviewed and collated. Results: The current knowledge and treatment of these aspects of wound healing in cancer patients are discussed, and observations and recommendations for optimal wound healing results are considered. Conclusion: Although wound healing may proceed in a relatively unimpeded manner for many patients with cancer, there is a potential for wound failure due to the nature and effects of the oncologic disease process and its treatments. PMID:18264518
SU-E-I-97: Smart Auto-Planning Framework in An EMR Environment (SAFEE)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, B; Chen, S; Mutaf, Y
2014-06-01
Purpose: Our Radiation Oncology Department uses clinical practice guidelines for patient treatment, including normal tissue sparing and other dosimetric constraints. These practice guidelines were adapted from national guidelines, clinical trials, literature reviews, and practitioner's own experience. Modern treatment planning systems (TPS) have the capability of incorporating these practice guidelines to automatically create radiation therapy treatment plans with little human intervention. We are developing a software infrastructure to integrate clinical practice guidelines and radiation oncology electronic medical record (EMR) system into radiation therapy treatment planning system (TPS) for auto planning. Methods: Our Smart Auto-Planning Framework in an EMR environment (SAFEE) usesmore » a software pipeline framework to integrate practice guidelines,EMR, and TPS together. The SAFEE system starts with retrieving diagnosis information and physician's prescription from the EMR system. After approval of contouring, SAFEE will automatically create plans according to our guidelines. Based on clinical objectives, SAFEE will automatically select treatment delivery techniques (such as, 3DRT/IMRT/VMAT) and optimize plans. When necessary, SAFEE will create multiple treatment plans with different combinations of parameters. SAFEE's pipeline structure makes it very flexible to integrate various techniques, such as, Model-Base Segmentation (MBS) and plan optimization algorithms, e.g., Multi-Criteria Optimization (MCO). In addition, SAFEE uses machine learning, data mining techniques, and an integrated database to create clinical knowledgebase and then answer clinical questions, such as, how to score plan quality or how volume overlap affects physicians' decision in beam and treatment technique selection. Results: In our institution, we use Varian Aria EMR system and RayStation TPS from RaySearch, whose ScriptService API allows control by external programs. These applications are the building blocks of our SAFEE system. Conclusion: SAFEE is a feasible method of integrating clinical information to develop an auto-planning paradigm to improve clinical workflow in cancer patient care.« less
Toward a web-based real-time radiation treatment planning system in a cloud computing environment.
Na, Yong Hum; Suh, Tae-Suk; Kapp, Daniel S; Xing, Lei
2013-09-21
To exploit the potential dosimetric advantages of intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), an in-depth approach is required to provide efficient computing methods. This needs to incorporate clinically related organ specific constraints, Monte Carlo (MC) dose calculations, and large-scale plan optimization. This paper describes our first steps toward a web-based real-time radiation treatment planning system in a cloud computing environment (CCE). The Amazon Elastic Compute Cloud (EC2) with a master node (named m2.xlarge containing 17.1 GB of memory, two virtual cores with 3.25 EC2 Compute Units each, 420 GB of instance storage, 64-bit platform) is used as the backbone of cloud computing for dose calculation and plan optimization. The master node is able to scale the workers on an 'on-demand' basis. MC dose calculation is employed to generate accurate beamlet dose kernels by parallel tasks. The intensity modulation optimization uses total-variation regularization (TVR) and generates piecewise constant fluence maps for each initial beam direction in a distributed manner over the CCE. The optimized fluence maps are segmented into deliverable apertures. The shape of each aperture is iteratively rectified to be a sequence of arcs using the manufacture's constraints. The output plan file from the EC2 is sent to the simple storage service. Three de-identified clinical cancer treatment plans have been studied for evaluating the performance of the new planning platform with 6 MV flattening filter free beams (40 × 40 cm(2)) from the Varian TrueBeam(TM) STx linear accelerator. A CCE leads to speed-ups of up to 14-fold for both dose kernel calculations and plan optimizations in the head and neck, lung, and prostate cancer cases considered in this study. The proposed system relies on a CCE that is able to provide an infrastructure for parallel and distributed computing. The resultant plans from the cloud computing are identical to PC-based IMRT and VMAT plans, confirming the reliability of the cloud computing platform. This cloud computing infrastructure has been established for a radiation treatment planning. It substantially improves the speed of inverse planning and makes future on-treatment adaptive re-planning possible.
Toward a web-based real-time radiation treatment planning system in a cloud computing environment
NASA Astrophysics Data System (ADS)
Hum Na, Yong; Suh, Tae-Suk; Kapp, Daniel S.; Xing, Lei
2013-09-01
To exploit the potential dosimetric advantages of intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), an in-depth approach is required to provide efficient computing methods. This needs to incorporate clinically related organ specific constraints, Monte Carlo (MC) dose calculations, and large-scale plan optimization. This paper describes our first steps toward a web-based real-time radiation treatment planning system in a cloud computing environment (CCE). The Amazon Elastic Compute Cloud (EC2) with a master node (named m2.xlarge containing 17.1 GB of memory, two virtual cores with 3.25 EC2 Compute Units each, 420 GB of instance storage, 64-bit platform) is used as the backbone of cloud computing for dose calculation and plan optimization. The master node is able to scale the workers on an ‘on-demand’ basis. MC dose calculation is employed to generate accurate beamlet dose kernels by parallel tasks. The intensity modulation optimization uses total-variation regularization (TVR) and generates piecewise constant fluence maps for each initial beam direction in a distributed manner over the CCE. The optimized fluence maps are segmented into deliverable apertures. The shape of each aperture is iteratively rectified to be a sequence of arcs using the manufacture’s constraints. The output plan file from the EC2 is sent to the simple storage service. Three de-identified clinical cancer treatment plans have been studied for evaluating the performance of the new planning platform with 6 MV flattening filter free beams (40 × 40 cm2) from the Varian TrueBeamTM STx linear accelerator. A CCE leads to speed-ups of up to 14-fold for both dose kernel calculations and plan optimizations in the head and neck, lung, and prostate cancer cases considered in this study. The proposed system relies on a CCE that is able to provide an infrastructure for parallel and distributed computing. The resultant plans from the cloud computing are identical to PC-based IMRT and VMAT plans, confirming the reliability of the cloud computing platform. This cloud computing infrastructure has been established for a radiation treatment planning. It substantially improves the speed of inverse planning and makes future on-treatment adaptive re-planning possible.
X-ray energy optimization in minibeam radiation therapy.
Prezado, Y; Thengumpallil, S; Renier, M; Bravin, A
2009-11-01
The purpose of this work is to assess which energy in minibeam radiation therapy provides the best compromise between the deposited dose in the tumor and the sparing of the healthy tissues. Monte Carlo simulations (PENELOPE 2006) have been used as a method to calculate the ratio of the peak-to-valley doses (PVDR) in the healthy tissues and in the tumor for different beam energies. The maximization of the ratio of PVDR in the healthy tissues and in the tumor has been used as a criterion. The main result of this work is that, for the parameters being used in preclinical trials (minibeam sizes of 600 microm and 1200 microm center-to-center separation), the optimum beam energy is 375 keV. The conclusion is that this is the energy of minibeams that should be used in the preclinical studies.
Dosimetric comparison between VMAT and RC3D techniques: case of prostate treatment
NASA Astrophysics Data System (ADS)
Chemingui, Fatima Zohra; Benrachi, Fatima; Bali, Mohamed Saleh; Ladjal, Hamid
2017-09-01
Considered as the second men cancer in Algeria, prostate cancer is treated in 70% by radiation. That's why radiation therapy is therapeutic weapon for prostate cancer. Conformational Radiotherapy in 3D is the most common technique [1-5]. The use of conventionally optimized treatment plans was compared at case scenario of optimized treatment plans VMAT for prostate cancer. The evaluation of the two optimizations strategies focused on the resulting plans ability to retain dose objectives under the influence of patient set up. Dose Volume Histogram in the Planning Target Volume and dose in the Organs At Risks were used to calculate the conformity index, and evaluation ratio of irradiated volume which represent the main tool of comparison [6,7]. The situation was analysed systematically. The 14% dose increase in the target leads to a decrease in the dose in adjacent organs with 39% in the bladder. Therefore, the criterion for better efficacy and less toxicity reveal that VMAT is the best choice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Filippi, Andrea Riccardo, E-mail: andreariccardo.filippi@unito.it; Ragona, Riccardo; Piva, Cristina
Purpose: The purpose of this study was to evaluate the risks of second cancers and cardiovascular diseases associated with an optimized volumetric modulated arc therapy (VMAT) planning solution in a selected cohort of stage I/II Hodgkin lymphoma (HL) patients treated with either involved-node or involved-site radiation therapy in comparison with 3-dimensional conformal radiation therapy (3D-CRT). Methods and Materials: Thirty-eight patients (13 males and 25 females) were included. Disease extent was mediastinum alone (n=8, 21.1%); mediastinum plus unilateral neck (n=19, 50%); mediastinum plus bilateral neck (n=11, 29.9%). Prescription dose was 30 Gy in 2-Gy fractions. Only 5 patients had mediastinal bulkymore » disease at diagnosis (13.1%). Anteroposterior 3D-CRT was compared with a multiarc optimized VMAT solution. Lung, breast, and thyroid cancer risks were estimated by calculating a lifetime attributable risk (LAR), with a LAR ratio (LAR{sub VMAT}-to-LAR{sub 3D-CRT}) as a comparative measure. Cardiac toxicity risks were estimated by calculating absolute excess risk (AER). Results: The LAR ratio favored 3D-CRT for lung cancer induction risk in mediastinal alone (P=.004) and mediastinal plus unilateral neck (P=.02) presentations. LAR ratio for breast cancer was lower for VMAT in mediastinal plus bilateral neck presentations (P=.02), without differences for other sites. For thyroid cancer, no significant differences were observed, regardless of anatomical presentation. A significantly lower AER of cardiac (P=.038) and valvular diseases (P<.0001) was observed for VMAT regardless of disease extent. Conclusions: In a cohort of patients with favorable characteristics in terms of disease extent at diagnosis (large prevalence of nonbulky presentations without axillary involvement), optimized VMAT reduced heart disease risk with comparable risks of thyroid and breast cancer, with an increase in lung cancer induction probability. The results are however strongly influenced by the different anatomical presentations, supporting an individualized approach.« less
3D conformal planning using low segment multi-criteria IMRT optimization
Khan, Fazal; Craft, David
2014-01-01
Purpose To evaluate automated multicriteria optimization (MCO) – designed for intensity modulated radiation therapy (IMRT), but invoked with limited segmentation – to efficiently produce high quality 3D conformal radiation therapy (3D-CRT) plans. Methods Ten patients previously planned with 3D-CRT to various disease sites (brain, breast, lung, abdomen, pelvis), were replanned with a low-segment inverse multicriteria optimized technique. The MCO-3D plans used the same beam geometry of the original 3D plans, but were limited to an energy of 6 MV. The MCO-3D plans were optimized using fluence-based MCO IMRT and then, after MCO navigation, segmented with a low number of segments. The 3D and MCO-3D plans were compared by evaluating mean dose for all structures, D95 (dose that 95% of the structure receives) and homogeneity indexes for targets, D1 and clinically appropriate dose volume objectives for individual organs at risk (OARs), monitor units (MUs), and physician preference. Results The MCO-3D plans reduced the OAR mean doses (41 out of a total of 45 OARs had a mean dose reduction, p<<0.01) and monitor units (seven out of ten plans have reduced MUs; the average reduction is 17%, p=0.08) while maintaining clinical standards on coverage and homogeneity of target volumes. All MCO-3D plans were preferred by physicians over their corresponding 3D plans. Conclusion High quality 3D plans can be produced using MCO-IMRT optimization, resulting in automated field-in-field type plans with good monitor unit efficiency. Adopting this technology in a clinic could improve plan quality, and streamline treatment plan production by utilizing a single system applicable to both IMRT and 3D planning. PMID:25413405
Lee, Ming; Reinertsen, Erik; McClure, Evan; Liu, Shuling; Kruper, Laura; Tanna, Neil; Brian Boyd, J; Granzow, Jay W
2015-11-01
Although postmastectomy radiation therapy (PMRT) has been shown to reduce breast cancer burden and improve survival, PMRT may negatively influence outcomes after reconstruction. The goal of this study was to compare current opinions of plastic and reconstructive surgeons (PRS) and surgical oncologists (SO) regarding the optimal timing of breast reconstruction for patients requiring PMRT. Members of the American Society of Plastic Surgeons (ASPS), the American Society of Breast Surgeons (ASBS), and the Society of Surgical Oncology (SSO) were asked to participate in an anonymous web-based survey. Responses were solicited in accordance to the Dillman method, and they were analyzed using standard descriptive statistics. A total of 330 members of the ASPS and 348 members of the ASBS and SSO participated in our survey. PRS and SO differed in patient-payor mix (p < 0.01) and practice setting (p < 0.01), but they did not differ by urban versus rural setting (p = 0.65) or geographic location (p = 0.30). Although PRS favored immediate reconstruction versus SO, overall timing did not significantly differ between the two specialists (p = 0.14). The primary rationale behind delayed breast reconstruction differed significantly between PRS and SO (p < 0.01), with more PRS believing that the reconstructive outcome is significantly and adversely affected by radiation. Both PRS and SO cited "patient-driven desire to have immediate reconstruction" (p = 0.86) as the primary motivation for immediate reconstruction. Although the optimal timing of reconstruction is controversial between PRS and SO, our study suggests that the timing of reconstruction in PMRT patients is ultimately driven by patient preferences and the desire of PRS to optimize aesthetic outcomes. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Markovic, Stacey; Belz, Jodi; Kumar, Rajiv; Cormack, Robert A; Sridhar, Srinivas; Niedre, Mark
2016-01-01
Drug loaded implants are a new, versatile technology platform to deliver a localized payload of drugs for various disease models. One example is the implantable nanoplatform for chemo-radiation therapy where inert brachytherapy spacers are replaced by spacers doped with nanoparticles (NPs) loaded with chemotherapeutics and placed directly at the disease site for long-term localized drug delivery. However, it is difficult to directly validate and optimize the diffusion of these doped NPs in in vivo systems. To better study this drug release and diffusion, we developed a custom macroscopic fluorescence imaging system to visualize and quantify fluorescent NP diffusion from spacers in vivo. To validate the platform, we studied the release of free fluorophores, and 30 nm and 200 nm NPs conjugated with the same fluorophores as a model drug, in agar gel phantoms in vitro and in mice in vivo. Our data verified that the diffusion volume was NP size-dependent in all cases. Our near-infrared imaging system provides a method by which NP diffusion from implantable nanoplatform for chemo-radiation therapy spacers can be systematically optimized (eg, particle size or charge) thereby improving treatment efficacy of the platform.
Survival times for canine intranasal sarcomas treated with radiation therapy: 86 cases (1996-2011).
Sones, Evan; Smith, Annette; Schleis, Stephanie; Brawner, William; Almond, Gregory; Taylor, Kathryn; Haney, Siobhan; Wypij, Jackie; Keyerleber, Michele; Arthur, Jennifer; Hamilton, Terrance; Lawrence, Jessica; Gieger, Tracy; Sellon, Rance; Wright, Zack
2013-01-01
Sarcomas comprise approximately one-third of canine intranasal tumors, however few veterinary studies have described survival times of dogs with histologic subtypes of sarcomas separately from other intranasal tumors. One objective of this study was to describe median survival times for dogs treated with radiation therapy for intranasal sarcomas. A second objective was to compare survival times for dogs treated with three radiation therapy protocols: daily-fractionated radiation therapy; Monday, Wednesday, and Friday fractionated radiation therapy; and palliative radiation therapy. Medical records were retrospectively reviewed for dogs that had been treated with radiation therapy for confirmed intranasal sarcoma. A total of 86 dogs met inclusion criteria. Overall median survival time for included dogs was 444 days. Median survival time for dogs with chondrosarcoma (n = 42) was 463 days, fibrosarcoma (n = 12) 379 days, osteosarcoma (n = 6) 624 days, and undifferentiated sarcoma (n = 22) 344 days. Dogs treated with daily-fractionated radiation therapy protocols; Monday, Wednesday and Friday fractionated radiation therapy protocols; and palliative radiation therapy protocols had median survival times of 641, 347, and 305 days, respectively. A significant difference in survival time was found for dogs receiving curative intent radiation therapy vs. palliative radiation therapy (P = 0.032). A significant difference in survival time was also found for dogs receiving daily-fractionated radiation therapy vs. Monday, Wednesday and Friday fractionated radiation therapy (P = 0.0134). Findings from this study support the use of curative intent radiation therapy for dogs with intranasal sarcoma. Future prospective, randomized trials are needed for confirmation of treatment benefits. © 2012 Veterinary Radiology & Ultrasound.
[Treatment of keratitis superficialis chronica of the dog with strontium 90].
Höcht, Stefan; Grüning, Georg; Allgoewer, Ingrid; Nausner, Martin; Brunnberg, Leo; Hinkelbein, Wolfgang
2002-02-01
Corneal pannus is a disease which, if untreated, nearly always is progressive and may lead to blindness of the affected dog. A therapeutic standard is yet to be defined. Beta-ray irradiation with Sr-90 is often recommended on a casuistic basis, but systematic studies are sparse. The aim of the present study was to evaluate efficacy and to document side effects of radiotherapy with Sr-90. 17 animals were treated. 13 of them received treatment of 15 Gy surface dose twice within 2 days with additional medical therapy with ciclosporin and prednisolon. Only the more affected eye was treated with radiation which was applied with an eye-applicator, the other eye served as control. Four animals with already advanced impairment of vision received keratectomy, afterwards radiation was applied on both sides. Medical treatment alone led to deterioration in vascularization and spread of pigmentation in eleven of 13 (85%) of the control-eyes, density of pigmentation increased in eight of 13 (62%). After radiation therapy, almost all animals showed a marked initial improvement. Even if progressive disease occurred later on, further worsening as it happened in the control-eyes could be stopped in nine resp. ten of 13 eyes (69% and 77%). All animals with keratectomy and radiotherapy regained and preserved adequate vision. Besides short-term blepharospasm, no side effects were recorded. Corneal pannus is responsive to radiation therapy with Sr-90 and long-term benefit can be achieved. Side effects are minimal. Optimal sequencing of therapy and dosage still have to be examined.
Nanodosimetry-Based Plan Optimization for Particle Therapy
Schulte, Reinhard W.
2015-01-01
Treatment planning for particle therapy is currently an active field of research due uncertainty in how to modify physical dose in order to create a uniform biological dose response in the target. A novel treatment plan optimization strategy based on measurable nanodosimetric quantities rather than biophysical models is proposed in this work. Simplified proton and carbon treatment plans were simulated in a water phantom to investigate the optimization feasibility. Track structures of the mixed radiation field produced at different depths in the target volume were simulated with Geant4-DNA and nanodosimetric descriptors were calculated. The fluences of the treatment field pencil beams were optimized in order to create a mixed field with equal nanodosimetric descriptors at each of the multiple positions in spread-out particle Bragg peaks. For both proton and carbon ion plans, a uniform spatial distribution of nanodosimetric descriptors could be obtained by optimizing opposing-field but not single-field plans. The results obtained indicate that uniform nanodosimetrically weighted plans, which may also be radiobiologically uniform, can be obtained with this approach. Future investigations need to demonstrate that this approach is also feasible for more complicated beam arrangements and that it leads to biologically uniform response in tumor cells and tissues. PMID:26167202
Matuszak, Martha M; Steers, Jennifer M; Long, Troy; McShan, Daniel L; Fraass, Benedick A; Romeijn, H Edwin; Ten Haken, Randall K
2013-07-01
To introduce a hybrid volumetric modulated arc therapy/intensity modulated radiation therapy (VMAT/IMRT) optimization strategy called FusionArc that combines the delivery efficiency of single-arc VMAT with the potentially desirable intensity modulation possible with IMRT. A beamlet-based inverse planning system was enhanced to combine the advantages of VMAT and IMRT into one comprehensive technique. In the hybrid strategy, baseline single-arc VMAT plans are optimized and then the current cost function gradients with respect to the beamlets are used to define a metric for predicting which beam angles would benefit from further intensity modulation. Beams with the highest metric values (called the gradient factor) are converted from VMAT apertures to IMRT fluence, and the optimization proceeds with the mixed variable set until convergence or until additional beams are selected for conversion. One phantom and two clinical cases were used to validate the gradient factor and characterize the FusionArc strategy. Comparisons were made between standard IMRT, single-arc VMAT, and FusionArc plans with one to five IMRT∕hybrid beams. The gradient factor was found to be highly predictive of the VMAT angles that would benefit plan quality the most from beam modulation. Over the three cases studied, a FusionArc plan with three converted beams achieved superior dosimetric quality with reductions in final cost ranging from 26.4% to 48.1% compared to single-arc VMAT. Additionally, the three beam FusionArc plans required 22.4%-43.7% fewer MU∕Gy than a seven beam IMRT plan. While the FusionArc plans with five converted beams offer larger reductions in final cost--32.9%-55.2% compared to single-arc VMAT--the decrease in MU∕Gy compared to IMRT was noticeably smaller at 12.2%-18.5%, when compared to IMRT. A hybrid VMAT∕IMRT strategy was implemented to find a high quality compromise between gantry-angle and intensity-based degrees of freedom. This optimization method will allow patients to be simultaneously planned for dosimetric quality and delivery efficiency without switching between delivery techniques. Example phantom and clinical cases suggest that the conversion of only three VMAT segments to modulated beams may result in a good combination of quality and efficiency.
Projections onto the Pareto surface in multicriteria radiation therapy optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bokrantz, Rasmus, E-mail: bokrantz@kth.se, E-mail: rasmus.bokrantz@raysearchlabs.com; Miettinen, Kaisa
2015-10-15
Purpose: To eliminate or reduce the error to Pareto optimality that arises in Pareto surface navigation when the Pareto surface is approximated by a small number of plans. Methods: The authors propose to project the navigated plan onto the Pareto surface as a postprocessing step to the navigation. The projection attempts to find a Pareto optimal plan that is at least as good as or better than the initial navigated plan with respect to all objective functions. An augmented form of projection is also suggested where dose–volume histogram constraints are used to prevent that the projection causes a violation ofmore » some clinical goal. The projections were evaluated with respect to planning for intensity modulated radiation therapy delivered by step-and-shoot and sliding window and spot-scanned intensity modulated proton therapy. Retrospective plans were generated for a prostate and a head and neck case. Results: The projections led to improved dose conformity and better sparing of organs at risk (OARs) for all three delivery techniques and both patient cases. The mean dose to OARs decreased by 3.1 Gy on average for the unconstrained form of the projection and by 2.0 Gy on average when dose–volume histogram constraints were used. No consistent improvements in target homogeneity were observed. Conclusions: There are situations when Pareto navigation leaves room for improvement in OAR sparing and dose conformity, for example, if the approximation of the Pareto surface is coarse or the problem formulation has too permissive constraints. A projection onto the Pareto surface can identify an inaccurate Pareto surface representation and, if necessary, improve the quality of the navigated plan.« less
NASA Astrophysics Data System (ADS)
Bae, Ji Yong; Nam, Ki-Hwan; Jeong, Chan Bae; Kim, Geon-hee; Chang, Ki Soo
2016-09-01
Over the last decade, plasmonic photothermal therapy (PPTT) has received significant attention as the new therapeutic strategy for the cancer therapy due to unique characteristics of the gold-nanoparticles. The characterization of the spatiotemporal heating potential for the gold nanorods (GNR) through mimicking PPTT process on the various conditions can help more quantitative approaches to treatment planning. The purpose of this study was to clearly understand the optical-thermal interactions between the laser, GNRs, and bio-tissues, and provide the information in clinical applications to implement the concept of heterogeneity, which can enable the optimization of treatment parameters for superficial breast cancer treatment.
Multiwave low-laser therapy in the pain treatment
NASA Astrophysics Data System (ADS)
Moldovan, Corneliu I.; Antipa, Ciprian; Bratila, Florin; Brukner, Ion; Vasiliu, Virgil V.
1995-03-01
Sixteen patients with knee pain, 17 patients with low back pain and 23 patients with vertebral pain were randomly allocated to multiwave laser therapy (MWL). The MWL was performed through an original method by a special designed laser system. The stimulation parameters adaptably optimized in a closed loop by measuring the reflected laser radiation. A control group of 11 patients was conventionally treated with a single infrared laser system. All patients were assessed by single observer using a visual analogue scale in a controlled trial. Our results indicate that the treatment with different laser wavelengths, different output power and frequencies, simultaneously applied through optic-fibers, has significant effects on the pain when compared with the common low laser therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hua, C.
This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, andmore » potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swanson, K; Corwin, D; Rockne, R
Purpose: To demonstrate a method of generating patient-specific, biologically-guided radiation therapy (RT) plans and to quantify and predict response to RT in glioblastoma. We investigate the biological correlates and imaging physics driving T2-MRI based response to radiation therapy using an MRI simulator. Methods: We have integrated a patient-specific biomathematical model of glioblastoma proliferation, invasion and radiotherapy with a multiobjective evolutionary algorithm for intensity-modulated RT optimization to construct individualized, biologically-guided plans. Patient-individualized simulations of the standard-of-care and optimized plans are compared in terms of several biological metrics quantified on MRI. An extension of the PI model is used to investigate themore » role of angiogenesis and its correlates in glioma response to therapy with the Proliferation-Invasion-Hypoxia- Necrosis-Angiogenesis model (PIHNA). The PIHNA model is used with a brain tissue phantom to predict tumor-induced vasogenic edema, tumor and tissue density that is used in a multi-compartmental MRI signal equation for generation of simulated T2- weighted MRIs. Results: Applying a novel metric of treatment response (Days Gained) to the patient-individualized simulation results predicted that the optimized RT plans would have a significant impact on delaying tumor progression, with Days Gained increases from 21% to 105%. For the T2- MRI simulations, initial validation tests compared average simulated T2 values for white matter, tumor, and peripheral edema to values cited in the literature. Simulated results closely match the characteristic T2 value for each tissue. Conclusion: Patient-individualized simulations using the combination of a biomathematical model with an optimization algorithm for RT generated biologically-guided doses that decreased normal tissue dose and increased therapeutic ratio with the potential to improve survival outcomes for treatment of glioblastoma. Simulated T2-MRI is shown to be consistent with known physics of MRI and can be used to further investigate biological drivers of imaging-based response to RT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paulson, Eric S., E-mail: epaulson@mcw.edu; Erickson, Beth; Schultz, Chris
Purpose: The use of magnetic resonance imaging (MRI) in radiation oncology is expanding rapidly, and more clinics are integrating MRI into their radiation therapy workflows. However, radiation therapy presents a new set of challenges and places additional constraints on MRI compared to diagnostic radiology that, if not properly addressed, can undermine the advantages MRI offers for radiation treatment planning (RTP). The authors introduce here strategies to manage several challenges of using MRI for virtual simulation in external beam RTP. Methods: A total of 810 clinical MRI simulation exams were performed using a dedicated MRI scanner for external beam RTP ofmore » brain, breast, cervix, head and neck, liver, pancreas, prostate, and sarcoma cancers. Patients were imaged in treatment position using MRI-optimal immobilization devices. Radiofrequency (RF) coil configurations and scan protocols were optimized based on RTP constraints. Off-resonance and gradient nonlinearity-induced geometric distortions were minimized or corrected prior to using images for RTP. A multidisciplinary MRI simulation guide, along with window width and level presets, was created to standardize use of MR images during RTP. A quality assurance program was implemented to maintain accuracy and repeatability of MRI simulation exams. Results: The combination of a large bore scanner, high field strength, and circumferentially wrapped, flexible phased array RF receive coils permitted acquisition of thin slice images with high contrast-to-noise ratio (CNR) and image intensity uniformity, while simultaneously accommodating patient setup and immobilization devices. Postprocessing corrections and alternative acquisition methods were required to reduce or correct off-resonance and gradient nonlinearity induced geometric distortions. Conclusions: The methodology described herein contains practical strategies the authors have implemented through lessons learned performing clinical MRI simulation exams. In their experience, these strategies provide robust, high fidelity, high contrast MR images suitable for external beam RTP.« less
Optimizing Radiation Therapy Quality Assurance in Clinical Trials: A TROG 08.03 RAVES Substudy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trada, Yuvnik, E-mail: yuvnik@gmail.com; Kneebone, Andrew; Paneghel, Andrea
2015-12-01
Purpose: To explore site- and clinician-level factors associated with protocol violations requiring real-time-review (RTR) resubmission in a multicenter clinical trial to help tailor future quality assurance (QA) protocols. Methods and Materials: RAVES (Radiation Therapy–Adjuvant vs Early Salvage) (Trans-Tasman Radiation Oncology Group 08.03) is a randomized trial comparing adjuvant with early salvage radiation therapy in men with positive surgical margins or pT3 disease after prostatectomy. Quality assurance in RAVES required each clinician and site to submit a credentialing dummy run (DR) and for each patient's radiation therapy plan to undergo external RTR before treatment. Prospectively defined major violations from trial protocol requiredmore » remedy and resubmission. Site and clinician factors associated with RTR resubmission were examined using hierarchical modeling. Results: Data were collected from 171 consecutive patients, treated by 46 clinicians at 32 hospitals. There were 47 RTR resubmissions (27%) due to 65 major violations. The relative rate of resubmission decreased by 29% per year as the study progressed (odds ratio OR. 0.71, P=.02). The majority of resubmissions were due to contouring violations (39 of 65) and dosimetric violations (22 of 65). For each additional patient accrued, significant decreases in RTR resubmission were seen at both clinician level (OR 0.75, P=.02) and site level (OR 0.72, P=.01). The rate of resubmission due to dosimetric violations was only 1.6% after the first 5 patients. Use of IMRT was associated with lower rates of resubmission compared with 3-dimensional conformal radiation therapy (OR 0.38, P=.05). Conclusion: Several low- and high-risk factors that may assist with tailoring future clinical trial QA were identified. Because the real-time resubmission rate was largely independent of the credentialing exercise, some form of RTR QA is recommended. The greatest benefit from QA was derived early in trial activation and clinician experience.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tan, J; Pompos, A; Jiang, S
Purpose: To put forth an innovative clinical paradigm for weekly chart checking so that treatment status is periodically checked accurately and efficiently. This study also aims to help optimize the chart checking clinical workflow in a busy radiation therapy clinic. Methods: It is mandated by the Texas Administrative code to check patient charts of radiation therapy once a week or every five fractions, however it varies drastically among institutions in terms of when and how it is done. Some do it every day, but a lot of efforts are wasted on opening ineligible charts; some do it on a fixedmore » day but the distribution of intervals between subsequent checks is not optimal. To establish an optimal chart checking procedure, a new paradigm was developed to achieve 1) charts are checked more accurately and more efficiently; 2) charts are checked on optimal days without any miss; 3) workload is evened out throughout a week when multiple physicists are involved. All active charts will be accessed by querying the R&V system. Priority is assigned to each chart based on the number of days before the next due date followed by sorting and workload distribution steps. New charts are also taken into account when distributing the workload so it is reasonably even throughout the week. Results: Our clinical workflow became more streamlined and smooth. In addition, charts get checked in a more timely fashion so that errors would get caught earlier should they occur. Conclusion: We developed a new weekly chart checking diagram. It helps physicists check charts in a timely manner, saves their time in busy clinics, and consequently reduces possible errors.« less
42 CFR 410.35 - X-ray therapy and other radiation therapy services: Scope.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false X-ray therapy and other radiation therapy services... Other Health Services § 410.35 X-ray therapy and other radiation therapy services: Scope. Medicare Part B pays for X-ray therapy and other radiation therapy services, including radium therapy and...
42 CFR 410.35 - X-ray therapy and other radiation therapy services: Scope.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false X-ray therapy and other radiation therapy services... Other Health Services § 410.35 X-ray therapy and other radiation therapy services: Scope. Medicare Part B pays for X-ray therapy and other radiation therapy services, including radium therapy and...
42 CFR 410.35 - X-ray therapy and other radiation therapy services: Scope.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false X-ray therapy and other radiation therapy services... Other Health Services § 410.35 X-ray therapy and other radiation therapy services: Scope. Medicare Part B pays for X-ray therapy and other radiation therapy services, including radium therapy and...
42 CFR 410.35 - X-ray therapy and other radiation therapy services: Scope.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false X-ray therapy and other radiation therapy services... Other Health Services § 410.35 X-ray therapy and other radiation therapy services: Scope. Medicare Part B pays for X-ray therapy and other radiation therapy services, including radium therapy and...
42 CFR 410.35 - X-ray therapy and other radiation therapy services: Scope.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false X-ray therapy and other radiation therapy services... Other Health Services § 410.35 X-ray therapy and other radiation therapy services: Scope. Medicare Part B pays for X-ray therapy and other radiation therapy services, including radium therapy and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Victor Ho Fun, E-mail: vhflee@hku.hk; Ng, Sherry Chor Yi; Kwong, Dora Lai Wan
The aim of this study was to investigate if intravenous contrast injection affected the radiation doses to carotid arteries and thyroid during intensity-modulated radiation therapy (IMRT) planning for nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC underwent plain computed tomography (CT) followed by repeated scanning after contrast injection. Carotid arteries (common, external, internal), thyroid, target volumes, and other organs-at-risk (OARs), as well as IMRT planning, were based on contrast-enhanced CT (CE-CT) images. All these structures and the IMRT plans were then copied and transferred to the non–contrast-enhanced CT (NCE-CT) images, and dose calculation without optimization was performed again. The radiationmore » doses to the carotid arteries and the thyroid based on CE-CT and NCE-CT were then compared. Based on CE-CT, no statistical differences, despite minute numeric decreases, were noted in all dosimetric parameters (minimum, maximum, mean, median, D05, and D01) of the target volumes, the OARs, the carotid arteries, and the thyroid compared with NCE-CT. Our results suggested that compared with NCE-CT planning, CE-CT scanning should be performed during IMRT for better target and OAR delineation, without discernible change in radiation doses.« less
National survey of perspectives of palliative radiation therapy: role, barriers, and needs.
McCloskey, Susan A; Tao, May Lin; Rose, Christopher M; Fink, Arlene; Amadeo, Alessandra M
2007-01-01
Despite growth of palliative care programs and evidence on the effectiveness of radiotherapy in palliating cancer symptoms, radiotherapy is probably underused in this setting. Radiation and medical oncologists and palliative medicine specialists were surveyed regarding the perceived role of palliative radiotherapy and barriers to its use. The survey was sent electronically to all physician members of the American Society for Therapeutic Radiology and Oncology (ASTRO) and the American Academy of Hospice and Palliative Medicine (AAHPM) and a random sample of American Society of Clinical Oncology (ASCO) members, with known e-mail addresses. Response rates were 27%, 14% and 26% for ASTRO, ASCO, and AAHPM respondents, respectively. Although most felt radiotherapy is an effective and important option for palliation of some common cancer symptoms, referrals for such therapy may be declining. Most agreed that radiation oncologists should be more involved in palliative care; however, multiple barriers were identified, such as poor reimbursement, emotional burden of care, insufficient training/knowledge, and the sense of unwillingness of others to share delivery of such services. Although multiple barriers limit optimal integration, most agree that there should be greater national and professional society efforts to promote the advancement of radiation oncology in the area of palliative care.
Stereotactic Body Radiation Therapy for Oligometastatic Prostate Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muldermans, Jonathan L.; Romak, Lindsay B.; Kwon, Eugene D.
Purpose: To review outcomes of patients with oligometastatic prostate cancer (PCa) treated with stereotactic body radiation therapy (SBRT) and to identify variables associated with local failure. Methods and Materials: We retrospectively reviewed records of patients treated with SBRT for oligometastatic PCa. Metastasis control (ie, control of the treated lesion, MC), biochemical progression-free survival, distant progression-free survival, and overall survival were estimated with the Kaplan-Meier method. Results: Sixty-six men with 81 metastatic PCa lesions, 50 of which were castrate-resistant, were included in the analysis. Lesions were in bone (n=74), lymph nodes (n=6), or liver (n=1). Stereotactic body radiation therapy was deliveredmore » in 1 fraction to 71 lesions (88%), at a median dose of 16 Gy (range, 16-24 Gy). The remaining lesions received 30 Gy in 3 fractions (n=6) or 50 Gy in 5 fractions (n=4). Median follow-up was 16 months (range, 3-49 months). Estimated MC at 2 years was 82%. Biochemical progression-free survival, distant progression-free survival, and overall survival were 54%, 45%, and 83%, respectively. On multivariate analysis, only the dose of SBRT was significantly associated with MC; lesions treated with 16 Gy had 58% MC, and those treated with ≥18 Gy had 95% MC at 2 years (P≤.001). At 2 years, MC for lesions treated with 18 Gy (n=21) was 88%. No patient treated with ≥18 Gy in a single fraction or with any multifraction regimen had local failure. Six patients (9%) had grade 1 pain flare, and 2 (3%) had grade 2 pain flare. No grade 2 or greater late toxicities were reported. Conclusions: Stereotactic body radiation therapy for patients with oligometastatic prostate cancer provided optimal metastasis control and acceptable toxicity with doses ≥18 Gy. Biochemical progression-free survival was 54% at 16 months with the inclusion of SBRT in the treatment regimen. Stereotactic body radiation therapy should be considered in patients with castration-refractory, oligometastatic prostate cancer who have limited options for systemic therapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, J
2016-06-15
Purpose: Develop a method to maximize the noncoplanar beam orientations and assure the beam delivery clearance for SBRT, therefore, optimize the dose conformality to the target, increase the dose sparing to the critical normal organs and reduce the hot spots in the body. Methods: A SBRT body frame (Elekta, Stockholm, Sweden) was used for patient immobilization and target localization. The SBRT body frame has CT fiducials on its side frames. After patient’s CT scan, the radiation treatment isocenter was defined and its coordinators referring to the body frame was calculated in the radiation treatment planning process. Meanwhile, initial beam orientationsmore » were designed based on the patient target and critical organ anatomy. The body frame was put on the linear accelerator couch and positioned to the calculated isocenter. Initially designed beam orientations were manually measured by tuning the body frame position on the couch, the gantry and couch angles. The finalized beam orientations were put into the treatment planning for dosimetric calculations. Results: Without patient presence, an optimal set of beam orientations were designed and validated. The radiation treatment plan was optimized and guaranteed for delivery clearance. Conclusion: The developed method is beneficial and effective in SBRT treatment planning for individual patient. It first allows maximizing the achievable noncoplanar beam orientation space, therefore, optimize the treatment plan for specific patient. It eliminates the risk that a plan needs to be modified due to the gantry and couch collision during patient setup.« less
21 CFR 892.5050 - Medical charged-particle radiation therapy system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical charged-particle radiation therapy system...-particle radiation therapy system. (a) Identification. A medical charged-particle radiation therapy system...) intended for use in radiation therapy. This generic type of device may include signal analysis and display...
Hodgkin lymphoma: 2018 update on diagnosis, risk-stratification, and management.
Ansell, Stephen M
2018-05-01
Hodgkin lymphoma (HL) is an uncommon B-cell lymphoid malignancy affecting 8500 new patients annually and representing approximately 10.2% of all lymphomas in the United States. HL is composed of two distinct disease entities: classical HL and nodular lymphocyte predominant HL. Nodular sclerosis, mixed cellularity, lymphocyte depletion, and lymphocyte-rich HL are subgroups of classical HL. An accurate assessment of the stage of disease in patients with HL is critical for the selection of the appropriate therapy. Prognostic models that identify patients at low or high risk for recurrence, as well as the response to therapy as determined by positron emission tomography scan, are used to optimize therapy. Initial therapy for HL patients is based on the histology of the disease, the anatomical stage and the presence of poor prognostic features. Patients with early stage disease are typically treated with combined modality strategies utilizing abbreviated courses of combination chemotherapy followed by involved-field radiation therapy, while those with advanced stage disease receive a longer course of chemotherapy often without radiation therapy. Newer agents including brentuximab vedotin are now being incorporated into frontline therapy and these new combinations are becoming a standard of care. High-dose chemotherapy (HDCT) followed by an autologous stem cell transplant (ASCT) is the standard of care for most patients who relapse following initial therapy. For patients who fail HDCT with ASCT, brentuximab vedotin, PD-1 blockade, nonmyeloablative allogeneic transplant or participation in a clinical trial should be considered. © 2018 Wiley Periodicals, Inc.
Chemoradiotherapy for esophageal squamous cell cancer.
Sasaki, Yusuke; Kato, Ken
2016-09-01
Chemoradiotherapy has been clinically indicated for patients with resectable esophageal squamous cell carcinoma who refuse surgical resection and in locally advanced unresectable esophageal squamous cell carcinoma patients. Concurrent chemoradiotherapy prolongs survival than radiation therapy alone when given as definitive treatment. Therefore, chemoradiotherapy is recognized as the standard non-invasive treatment for patients with localized esophageal cancer who opt for non-surgical treatment. JCOG9906 showed promising outcomes for stage II/III ESCC patients. But there are some problems about chemoradiotherapy for esophageal squamous cell carcinoma. Late toxicities are sometimes lethal for patients who achieved complete response even after years. Salvage treatment for residual or recurrent disease is unestablished. Modified Radiation Therapy Oncology Group regimen at the dose of 50.4 Gy reduced late toxicities without reducing efficacy. Optimal timings and procedure of salvage surgery and endoscopic therapy is evaluated in JCOG0909. Strategy including salvage therapy after chemoradiotherapy should be considered at the time of starting the treatment. Targeted therapy has not shown adding effect for chemoradiotherapy for esophageal squamous cell carcinoma yet. New agents, such as immune checkpoint inhibitors, are expected to show synergistic effect with chemoradiotherapy for esophageal squamous cell carcinoma. Further investigation is needed. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Accelerating IMRT optimization by voxel sampling
NASA Astrophysics Data System (ADS)
Martin, Benjamin C.; Bortfeld, Thomas R.; Castañon, David A.
2007-12-01
This paper presents a new method for accelerating intensity-modulated radiation therapy (IMRT) optimization using voxel sampling. Rather than calculating the dose to the entire patient at each step in the optimization, the dose is only calculated for some randomly selected voxels. Those voxels are then used to calculate estimates of the objective and gradient which are used in a randomized version of a steepest descent algorithm. By selecting different voxels on each step, we are able to find an optimal solution to the full problem. We also present an algorithm to automatically choose the best sampling rate for each structure within the patient during the optimization. Seeking further improvements, we experimented with several other gradient-based optimization algorithms and found that the delta-bar-delta algorithm performs well despite the randomness. Overall, we were able to achieve approximately an order of magnitude speedup on our test case as compared to steepest descent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lalani, Nafisha; Paszat, Lawrence; Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, Ontario
Purpose: Whole-breast radiation therapy (XRT) after breast-conserving surgery (BCS) for ductal carcinoma in situ (DCIS) may decrease the risk of local recurrence, but the optimal dose regimen remains unclear. Past studies administered 50 Gy in 25 fractions (conventional); however, treatment pattern studies report that hypofractionated (HF) regimens (42.4 Gy in 16 fractions) are frequently used. We report the impact of HF (vs conventional) on the risk of local recurrence after BCS for DCIS. Methods and Materials: All women with DCIS treated with BCS and XRT in Ontario, Canada from 1994 to 2003 were identified. Treatment and outcomes were assessed through administrative databasesmore » and validated by chart review. Survival analyses were performed. To account for systematic differences between women treated with alternate regimens, we used a propensity score adjustment approach. Results: We identified 1609 women, of whom 971 (60%) received conventional regimens and 638 (40%) received HF. A total of 489 patients (30%) received a boost dose, of whom 143 (15%) received conventional radiation therapy and 346 (54%) received HF. The median follow-up time was 9.2 years. The median age at diagnosis was 56 years (interquartile range [IQR], 49-65 years). On univariate analyses, the 10-year actuarial local recurrence–free survival was 86% for conventional radiation therapy and 89% for HF (P=.03). On multivariable analyses, age <45 years (hazard ratio [HR] = 2.4; 95% CI: 1.6-3.4; P<.0001), high (HR=2.9; 95% CI: 1.2-7.3; P=.02) or intermediate nuclear grade (HR=2.7; 95% CI: 1.1-6.6; P=.04), and positive resection margins (HR=1.4; 95% CI: 1.0-2.1; P=.05) were associated with an increased risk of local recurrence. HF was not significantly associated with an increased risk of local recurrence compared with conventional radiation therapy on multivariate analysis (HR=0.8; 95% CI: 0.5-1.2; P=.34). Conclusions: The risk of local recurrence among individuals treated with HF regimens after BCS for DCIS was similar to that among individuals treated with conventional radiation therapy.« less
Chaikh, Abdulhamid; Calugaru, Valentin; Bondiau, Pierre-Yves; Thariat, Juliette; Balosso, Jacques
2018-06-07
The aim of this study is to evaluate the impact of normal tissue complication probability (NTCP)-based radiobiological models on the estimated risk for late radiation lung damages. The second goal is to propose a medical decision-making approach to select the eligible patient for particle therapy. 14 pediatric patients undergoing cranio-spinal irradiation were evaluated. For each patient, two treatment plans were generated using photon and proton therapy with the same dose prescriptions. Late radiation damage to lung was estimated using three NTCP concepts: the Lyman-Kutcher-Burman, the equivalent uniform dose (EUD) and the mean lung dose according to the quantitative analysis of normal tissue effects in the clinic QUANTEC review. Wilcoxon paired test was used to calculate p-value. Proton therapy achieved lower lung EUD (Gy). The average NTCP values were significantly lower with proton plans, p < 0.05, using the three NTCP concepts. However, applying the same TD 50/5 using radiobiological models to compare NTCP from proton and photon therapy, the ΔNTCP was not a convincing method to measure the potential benefit of proton therapy. Late radiation pneumonitis estimated from the mean lung dose model correlated with QUANTEC data better. treatment effectiveness assessed on NTCP reduction depends on radiobiological predictions and parameters used as inputs for in silico evaluation. Since estimates of absolute NTCP values from LKB and GN models are imprecise due to EUD ≪ TD 50/5 , a reduction of the EUD value with proton plans would better predict a reduction of dose/toxicity. The EUD concept appears as a robust radiobiological surrogate of the dose distribution to select the optimal patient's plan.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCowan, Peter M., E-mail: pmccowan@cancercare.mb.ca; Asuni, Ganiyu; Van Uytven, Eric
Purpose: To report findings from an in vivo dosimetry program implemented for all stereotactic body radiation therapy patients over a 31-month period and discuss the value and challenges of utilizing in vivo electronic portal imaging device (EPID) dosimetry clinically. Methods and Materials: From December 2013 to July 2016, 117 stereotactic body radiation therapy–volumetric modulated arc therapy patients (100 lung, 15 spine, and 2 liver) underwent 602 EPID-based in vivo dose verification events. A developed model-based dose reconstruction algorithm calculates the 3-dimensional dose distribution to the patient by back-projecting the primary fluence measured by the EPID during treatment. The EPID frame-averaging was optimized in Junemore » 2015. For each treatment, a 3%/3-mm γ comparison between our EPID-derived dose and the Eclipse AcurosXB–predicted dose to the planning target volume (PTV) and the ≥20% isodose volume were performed. Alert levels were defined as γ pass rates <85% (lung and liver) and <80% (spine). Investigations were carried out for all fractions exceeding the alert level and were classified as follows: EPID-related, algorithmic, patient setup, anatomic change, or unknown/unidentified errors. Results: The percentages of fractions exceeding the alert levels were 22.6% for lung before frame-average optimization and 8.0% for lung, 20.0% for spine, and 10.0% for liver after frame-average optimization. Overall, mean (± standard deviation) planning target volume γ pass rates were 90.7% ± 9.2%, 87.0% ± 9.3%, and 91.2% ± 3.4% for the lung, spine, and liver patients, respectively. Conclusions: Results from the clinical implementation of our model-based in vivo dose verification method using on-treatment EPID images is reported. The method is demonstrated to be valuable for routine clinical use for verifying delivered dose as well as for detecting errors.« less
Tetar, Shyama; Bohoudi, Omar; Nieboer, Theodoor; Lagerwaard, Frank
2018-01-01
In this case presentation, we describe the challenges of performing magnetic resonance-guided radiation therapy (MRgRT) with plan adaptation in a patient with advanced endometriosis, in whom several prior therapeutic attempts were unsuccessful and extensive pelvic irradiation was regarded as being too toxic. Treatment was delivered in two sessions, first for the seemingly only active right ovary, and at a later stage for the left ovary. Some logistical problems were encountered during the preparation of the first treatment, which were subsequently optimized for the second treatment by using transvaginal ultrasound to determine the optimum time point for simulation and delivery. Using breath-hold gated delivery and plan adaptation, radiation dose to the bowel could be minimized, resulting in good tolerance of treatment. Because of the need to simulate and deliver in a brief optimal time span for visibility of the follicles in the ovaries, a single fraction dose of 8 Gy was used in our patient. Hormonal outcome after her second treatment is still pending. In conclusion, MRgRT with plan adaptation is feasible for the occasional patient with refractory endometriosis. Simulation and delivery needs to be synchronized with the menstrual cycle, ensuring that the Graafian follicles allow the ovaries to be visible on magnetic resonance imaging (MRI). Because the ovaries are only visible on T2-weighted MRI for a very brief period of time, we suggest that it is preferable to use single fraction radiotherapy with a brief interval between simulation imaging and delivery. PMID:29750135
Jalali, Mir Mohammad; Gerami, Hooshang; Rahimi, Abbas; Jafari, Manizheh
2014-10-01
Radiotherapy is a common treatment modality for patients with head and neck malignancies. As the nose lies within the field of radiotherapy of the head and neck, the olfactory fibers and olfactory receptors may be affected by radiation. The aim of this study was to evaluate changes in olfactory threshold in patients with head and neck malignancies who have received radiation to the head and neck. The olfactory threshold of patients with head and neck malignancies was assessed prospectively before radiation therapy and serially for up to 6 months after radiotherapy using sniff bottles. In vivo dosimetry was performed using 82 LiF (MCP) chips and a thermoluminescent dosimeter (TLD) system. Sixty-one patients were recruited before radiotherapy was commenced. Seven patients did not return for evaluation after radiation. Fifty-four patients were available for follow-up assessment (28 women, 26 men; age, 22-86 years; median, 49 years). Total radiation dose was 50.1 Gy (range, 30-66 Gy). Mean olfactory threshold scores were found to deteriorate significantly at various timepoints after radiotherapy (11.7 before radiotherapy versus 4.0 at Month 6, general linear model, P<0.0001). With in vivo dosimetry, we found that the median measured dose to the olfactory area was 334 µC. We also identified a cutoff point according to the dose to the olfactory epithelium. Olfactory threshold was significantly decreased 2-6 weeks after initiation of therapy, with cumulative local radiation >135 µC (Mann-Whitney U test, P=0.01). Deterioration in olfactory threshold scores was found at 6 months after initiation of radiation therapy. Provided that these results are reproducible, an evaluation of olfactory functioning in patients with head and neck malignancies using in vivo dosimetry may be useful for determining the optimal dose for patients treated with conformal radiotherapy techniques while avoiding the side effects of radiation.
Ansell, Stephen M
2011-10-01
Hodgkin lymphoma (HL) is an uncommon B-cell lymphoid malignancy affecting 8,500 new patients annually and representing approximately 11% of all lymphomas in the United States. HL is composed of two distinct disease entities; the more commonly diagnosed classical HL and the rare nodular lymphocyte predominant HL. Nodular sclerosis, mixed cellularity, lymphocyte depletion, and lymphocyte-rich HL are subgroups under the designation of classical HL. An accurate assessment of the stage of disease in patients with HL is critical for the selection of the appropriate therapy. Prognostic models that identify patients at low or high risk for recurrence are used to optimize therapy for patients with limited or advanced stage disease. Initial therapy for HL patients is based on the histology of the disease, the anatomical stage, and the presence of poor prognostic features. Patients with early stage disease are treated with combined modality strategies using abbreviated courses of combination chemotherapy followed by involved-field radiation therapy, while those with advanced stage disease receive a longer course of chemotherapy often without radiation therapy. High-dose chemotherapy (HDCT) followed by an autologous stem-cell transplant (ASCT) is the standard of care for most patients who relapse following initial therapy. For patients who fail HDCT with ASCT, palliative chemotherapy, nonmyeloablative allogeneic transplant, or participation in a clinical trial should be considered. 2011 Wiley-Liss, Inc.
Hodgkin lymphoma: 2012 update on diagnosis, risk-stratification, and management.
Ansell, Stephen M
2012-12-01
Hodgkin lymphoma (HL) is an uncommon B-cell lymphoid malignancy affecting 9,000 new patients annually and representing approximately 11% of all lymphomas in the United States. HL is composed of two distinct disease entities; the more commonly diagnosed classical HL and the rare nodular lymphocyte predominant HL. Nodular sclerosis, mixed cellularity, lymphocyte depletion, and lymphocyte-rich HL are subgroups under the designation of classical HL. An accurate assessment of the stage of disease in patients with HL is critical for the selection of the appropriate therapy. Prognostic models that identify patients at low or high risk for recurrence are used to optimize therapy for patients with limited or advanced stage disease. Initial therapy for HL patients is based on the histology of the disease, the anatomical stage and the presence of poor prognostic features. Patients with early stage disease are treated with combined modality strategies utilizing abbreviated courses of combination chemotherapy followed by involved-field radiation therapy, while those with advanced stage disease receive a longer course of chemotherapy often without radiation therapy. High-dose chemotherapy (HDCT) followed by an autologous stem cell transplant (ASCT) is the standard of care for most patients who relapse following initial therapy. For patients who fail HDCT with ASCT, brentuximab vedotin, palliative chemotherapy, non-myeloablative allogeneic transplant or participation in a clinical trial should be considered. Copyright © 2012 Wiley Periodicals, Inc.
Lane, Whitney O; Nussbaum, Daniel P; Sun, Zhifei; Blazer, Dan G
2018-05-25
Although surgery remains the cornerstone of gastric cancer therapy, the use of radiation therapy (RT) is increasingly being employed to optimize outcomes. We sought to assess outcomes following use of RT for the treatment of gastric adenocarcinoma. Using the National Cancer Data Base (NCDB) from 1998 to 2012, all patients with resected gastric adenocarcinoma were identified. Patients were stratified into four groups based on preoperative therapy: RT alone, chemotherapy only, chemoradiotherapy (CRT), and no preoperative therapy. Overall survival was estimated using multivariate Cox proportional hazards model. Adjusted secondary outcomes include margin positivity, lymph node harvest, LOS, 30-day readmission and mortality. A total of 10 019 patients met study criteria. In the unadjusted analysis, patients undergoing CRT compared to chemotherapy alone had fewer positive margins (7.9% vs 15.9%; P < 0.001), increased negative LNs (54.6% vs 37.7%; P < 0.001) with reduced LN retrieval (mean: 13.5 vs 19.6; P < 0.01). After multivariate adjustment, there was no survival benefit to any preoperative therapy; however, preoperative RT/CRT remained associated with decreased LN retrieval. The results support previous reports on preoperative RT resulting in decreased margin positivity. This study highlights the need to reconsider practice guidelines regarding appropriate lymphadenectomy in the setting of preoperative RT given reduced LN retrieval. © 2018 Wiley Periodicals, Inc.
Applications of Machine Learning for Radiation Therapy.
Arimura, Hidetaka; Nakamoto, Takahiro
2016-01-01
Radiation therapy has been highly advanced as image guided radiation therapy (IGRT) by making advantage of image engineering technologies. Recently, novel frameworks based on image engineering technologies as well as machine learning technologies have been studied for sophisticating the radiation therapy. In this review paper, the author introduces several researches of applications of machine learning for radiation therapy. For examples, a method to determine the threshold values for standardized uptake value (SUV) for estimation of gross tumor volume (GTV) in positron emission tomography (PET) images, an approach to estimate the multileaf collimator (MLC) position errors between treatment plans and radiation delivery time, and prediction frameworks for esophageal stenosis and radiation pneumonitis risk after radiation therapy are described. Finally, the author introduces seven issues that one should consider when applying machine learning models to radiation therapy.
WE-AB-209-09: Optimization of Rotational Arc Station Parameter Optimized Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, P; Xing, L; Ungun, B
Purpose: To develop a fast optimization method for station parameter optimized radiation therapy (SPORT) and show that SPORT is capable of improving VMAT in both plan quality and delivery efficiency. Methods: The angular space from 0° to 360° was divided into 180 station points (SPs). A candidate aperture was assigned to each of the SPs based on the calculation results using a column generation algorithm. The weights of the apertures were then obtained by optimizing the objective function using a state-of-the-art GPU based Proximal Operator Graph Solver (POGS) within seconds. Apertures with zero or low weight were thrown out. Tomore » avoid being trapped in a local minimum, a stochastic gradient descent method was employed which also greatly increased the convergence rate of the objective function. The above procedure repeated until the plan could not be improved any further. A weighting factor associated with the total plan MU also indirectly controlled the complexities of aperture shapes. The number of apertures for VMAT and SPORT was confined to 180. The SPORT allowed the coexistence of multiple apertures in a single SP. The optimization technique was assessed by using three clinical cases (prostate, H&N and brain). Results: Marked dosimetric quality improvement was demonstrated in the SPORT plans for all three studied cases. Prostate case: the volume of the 50% prescription dose was decreased by 22% for the rectum. H&N case: SPORT improved the mean dose for the left and right parotids by 15% each. Brain case: the doses to the eyes, chiasm and inner ears were all improved. SPORT shortened the treatment time by ∼1 min for the prostate case, ∼0.5 min for brain case, and ∼0.2 min for the H&N case. Conclusion: The superior dosimetric quality and delivery efficiency presented here indicates that SPORT is an intriguing alternative treatment modality.« less
The role of medical physics in prostate cancer radiation therapy.
Fiorino, Claudio; Seuntjens, Jan
2016-03-01
Medical physics, both as a scientific discipline and clinical service, hugely contributed and still contributes to the advances in the radiotherapy of prostate cancer. The traditional translational role in developing and safely implementing new technology and methods for better optimizing, delivering and monitoring the treatment is rapidly expanding to include new fields such as quantitative morphological and functional imaging and the possibility of individually predicting outcome and toxicity. The pivotal position of medical physicists in treatment personalization probably represents the main challenge of current and next years and needs a gradual change of vision and training, without losing the traditional and fundamental role of physicists to guarantee a high quality of the treatment. The current focus issue is intended to cover traditional and new fields of investigation in prostate cancer radiation therapy with the aim to provide up-to-date reference material to medical physicists daily working to cure prostate cancer patients. The papers presented in this focus issue touch upon present and upcoming challenges that need to be met in order to further advance prostate cancer radiation therapy. We suggest that there is a smart future for medical physicists willing to perform research and innovate, while they continue to provide high-quality clinical service. However, physicists are increasingly expected to actively integrate their implicitly translational, flexible and high-level skills within multi-disciplinary teams including many clinical figures (first of all radiation oncologists) as well as scientists from other disciplines. Copyright © 2016. Published by Elsevier Ltd.
Bohoudi, O; Bruynzeel, A M E; Senan, S; Cuijpers, J P; Slotman, B J; Lagerwaard, F J; Palacios, M A
2017-12-01
To implement a robust and fast stereotactic MR-guided adaptive radiation therapy (SMART) online strategy in locally advanced pancreatic cancer (LAPC). SMART strategy for plan adaptation was implemented with the MRIdian system (ViewRay Inc.). At each fraction, OAR (re-)contouring is done within a distance of 3cm from the PTV surface. Online plan re-optimization is based on robust prediction of OAR dose and optimization objectives, obtained by building an artificial neural network (ANN). Proposed limited re-contouring strategy for plan adaptation (SMART 3CM ) is evaluated by comparing 50 previously delivered fractions against a standard (re-)planning method using full-scale OAR (re-)contouring (FULLOAR). Plan quality was assessed using PTV coverage (V 95% , D mean , D 1cc ) and institutional OAR constraints (e.g. V 33Gy ). SMART 3CM required a significant lower number of optimizations than FULLOAR (4 vs 18 on average) to generate a plan meeting all objectives and institutional OAR constraints. PTV coverage with both strategies was identical (mean V 95% =89%). Adaptive plans with SMART 3CM exhibited significant lower intermediate and high doses to all OARs than FULLOAR, which also failed in 36% of the cases to adhere to the V 33Gy dose constraint. SMART 3CM approach for LAPC allows good OAR sparing and adequate target coverage while requiring only limited online (re-)contouring from clinicians. Copyright © 2017 Elsevier B.V. All rights reserved.
Ataxia-telangiectasia gene (ATM) mutation heterozygosity in breast cancer: a narrative review.
Jerzak, K J; Mancuso, T; Eisen, A
2018-04-01
Despite the fact that heterozygosity for a pathogenic ATM variant is present in 1%-2% of the adult population, clinical guidelines to inform physicians and genetic counsellors about optimal management in that population are lacking. In this narrative review, we describe the challenges and controversies in the management of women who are heterozygous for a pathogenic ATM variant with respect to screening for breast and other malignancies, to choices for systemic therapy, and to decisions about radiation therapy. Given that the lifetime risk for breast cancer in women who are heterozygous for a pathogenic ATM variant is likely greater than 25%, those women should undergo annual mammographic screening starting at least by 40 years of age. For women in this group who have a strong family history of breast cancer, earlier screening with both magnetic resonance imaging and mammography should be considered. High-quality data to inform the management of established breast cancer in carriers of pathogenic ATM variants are lacking. Although deficiency in the ATM gene product might confer sensitivity to dna-damaging pharmaceuticals such as inhibitors of poly (adp-ribose) polymerase or platinum agents, prospective clinical trials have not been conducted in the relevant patient population. Furthermore, the evidence with respect to radiation therapy is mixed; some data suggest increased toxicity, and other data suggest improved clinical benefit from radiation in women who are carriers of a pathogenic ATM variant. As in the 2017 U.S. National Comprehensive Cancer Network guidelines, we recommend high-risk imaging for women in Ontario who are heterozygous for a pathogenic ATM variant. Currently, ATM carrier status should not influence decisions about systemic or radiation therapy in the setting of an established breast cancer diagnosis.
Tyson, Mark D; Penson, David F; Resnick, Matthew J
2017-02-01
The primary goal of modern prostate cancer treatment paradigms is to optimize the balance of predicted benefits associated with prostate cancer treatment against the predicted harms of therapy. However, given the limitations in the existing evidence as well as the significant tradeoffs posed by each treatment, there remain myriad challenges associated with individualized prostate cancer treatment decision-making. In this review, we summarize the existing comparative effectiveness evidence of treatments for localized prostate cancer with an emphasis on oncologic control. While we focus on the major treatment categories of radical prostatectomy, radiation therapy, and observation, we also provide a review of emerging therapies such as cryotherapy and high-intensity frequency ultrasound (HIFU). Copyright © 2017 Elsevier Inc. All rights reserved.
Pirfenidone enhances the efficacy of combined radiation and sunitinib therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Seo-Hyun; Nam, Jae-Kyung; Jang, Junho
Radiotherapy is a widely used treatment for many tumors. Combination therapy using anti-angiogenic agents and radiation has shown promise; however, these combined therapies are reported to have many limitations in clinical trials. Here, we show that radiation transformed tumor endothelial cells (ECs) to fibroblasts, resulting in reduced vascular endothelial growth factor (VEGF) response and increased Snail1, Twist1, Type I collagen, and transforming growth factor (TGF)-β release. Irradiation of radioresistant Lewis lung carcinoma (LLC) tumors greater than 250 mm{sup 3} increased collagen levels, particularly in large tumor vessels. Furthermore, concomitant sunitinib therapy did not show a significant difference in tumor inhibition versusmore » radiation alone. Thus, we evaluated multimodal therapy that combined pirfenidone, an inhibitor of TGF-induced collagen production, with radiation and sunitinib treatment. This trimodal therapy significantly reduced tumor growth, as compared to radiation alone. Immunohistochemical analysis revealed that radiation-induced collagen deposition and tumor microvessel density were significantly reduced with trimodal therapy, as compared to radiation alone. These data suggest that combined therapy using pirfenidone may modulate the radiation-altered tumor microenvironment, thereby enhancing the efficacy of radiation therapy and concurrent chemotherapy. - Highlights: • Radiation changes tumor endothelial cells to fibroblasts. • Radio-resistant tumors contain collagen deposits, especially in tumor vessels. • Pirfenidone enhances the efficacy of combined radiation and sunitinib therapy. • Pirfenidone reduces radiation-induced collagen deposits in tumors.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Lingzhi, E-mail: hlingzhi@gmail.com, E-mail: raymond.muzic@case.edu; Traughber, Melanie; Su, Kuan-Hao
Purpose: The ultrashort echo-time (UTE) sequence is a promising MR pulse sequence for imaging cortical bone which is otherwise difficult to image using conventional MR sequences and also poses strong attenuation for photons in radiation therapy and PET imaging. The authors report here a systematic characterization of cortical bone signal decay and a scanning time optimization strategy for the UTE sequence through k-space undersampling, which can result in up to a 75% reduction in acquisition time. Using the undersampled UTE imaging sequence, the authors also attempted to quantitatively investigate the MR properties of cortical bone in healthy volunteers, thus demonstratingmore » the feasibility of using such a technique for generating bone-enhanced images which can be used for radiation therapy planning and attenuation correction with PET/MR. Methods: An angularly undersampled, radially encoded UTE sequence was used for scanning the brains of healthy volunteers. Quantitative MR characterization of tissue properties, including water fraction and R2{sup ∗} = 1/T2{sup ∗}, was performed by analyzing the UTE images acquired at multiple echo times. The impact of different sampling rates was evaluated through systematic comparison of the MR image quality, bone-enhanced image quality, image noise, water fraction, and R2{sup ∗} of cortical bone. Results: A reduced angular sampling rate of the UTE trajectory achieves acquisition durations in proportion to the sampling rate and in as short as 25% of the time required for full sampling using a standard Cartesian acquisition, while preserving unique MR contrast within the skull at the cost of a minimal increase in noise level. The R2{sup ∗} of human skull was measured as 0.2–0.3 ms{sup −1} depending on the specific region, which is more than ten times greater than the R2{sup ∗} of soft tissue. The water fraction in human skull was measured to be 60%–80%, which is significantly less than the >90% water fraction in brain. High-quality, bone-enhanced images can be generated using a reduced sampled UTE sequence with no visible compromise in image quality and they preserved bone-to-air contrast with as low as a 25% sampling rate. Conclusions: This UTE strategy with angular undersampling preserves the image quality and contrast of cortical bone, while reducing the total scanning time by as much as 75%. The quantitative results of R2{sup ∗} and the water fraction of skull based on Dixon analysis of UTE images acquired at multiple echo times provide guidance for the clinical adoption and further parameter optimization of the UTE sequence when used for radiation therapy and MR-based PET attenuation correction.« less
Hodgkin lymphoma: 2016 update on diagnosis, risk-stratification, and management.
Ansell, Stephen M
2016-06-01
Hodgkin lymphoma (HL) is an uncommon B-cell lymphoid malignancy affecting 9,050 new patients annually and representing approximately 11.2% of all lymphomas in the United States. HL is composed of two distinct disease entities; the more commonly diagnosed classical HL and the rare nodular lymphocyte predominant HL. Nodular sclerosis, mixed cellularity, lymphocyte depletion, and lymphocyte-rich HL are subgroups under the designation of classical HL. An accurate assessment of the stage of disease in patients with HL is critical for the selection of the appropriate therapy. Prognostic models that identify patients at low or high risk for recurrence, as well as the response to therapy as determined by positron emission tomography (PET) scan, are used to optimize therapy. Initial therapy for HL patients is based on the histology of the disease, the anatomical stage and the presence of poor prognostic features. Patients with early stage disease are typically treated with combined modality strategies utilizing abbreviated courses of combination chemotherapy followed by involved-field radiation therapy, while those with advanced stage disease receive a longer course of chemotherapy often without radiation therapy. Management of relapsed/refractory disease: High-dose chemotherapy (HDCT) followed by an autologous stem cell transplant (ASCT) is the standard of care for most patients who relapse following initial therapy. For patients who fail HDCT with ASCT, brentuximab vedotin, PD-1 blockade, nonmyeloablative allogeneic transplant or participation in a clinical trial should be considered. © 2016 Wiley Periodicals, Inc.
Hodgkin lymphoma: 2014 update on diagnosis, risk-stratification, and management.
Ansell, Stephen M
2014-07-01
Hodgkin lymphoma (HL) is an uncommon B-cell lymphoid malignancy affecting 9,200 new patients annually and representing approximately 11.5% of all lymphomas in the United States. HL is composed of two distinct disease entities; the more commonly diagnosed classical HL and the rare nodular lymphocyte-predominant HL. Nodular sclerosis, mixed cellularity, lymphocyte depletion, and lymphocyte-rich HL are subgroups under the designation of classical HL. An accurate assessment of the stage of disease in patients with HL is critical for the selection of the appropriate therapy. Prognostic models that identify patients at low or high risk for recurrence, as well as the response to therapy as determined by positron emission tomography scan, are used to optimize therapy. Initial therapy for HL patients is based on the histology of the disease, the anatomical stage, and the presence of poor prognostic features. Patients with early stage disease are treated with combined modality strategies using abbreviated courses of combination chemotherapy followed by involved-field radiation therapy, while those with advanced stage disease receive a longer course of chemotherapy often without radiation therapy. Management of relapsed/refractory disease: High-dose chemotherapy (HDCT) followed by an autologous stem cell transplant (ASCT) is the standard of care for most patients who relapse following initial therapy. For patients who fail HDCT with ASCT, brentuximab vedotin, palliative chemotherapy, nonmyeloablative allogeneic transplant, or participation in a clinical trial should be considered. © 2014 Wiley Periodicals, Inc.
Svensson, Roger; Larsson, Susanne; Gudowska, Irena; Holmberg, Rickard; Brahme, Anders
2007-03-01
Intensity modulated radiation therapy is rapidly becoming the treatment of choice for most tumors with respect to minimizing damage to the normal tissues and maximizing tumor control. Today, intensity modulated beams are most commonly delivered using segmental multileaf collimation, although an increasing number of radiation therapy departments are employing dynamic multileaf collimation. The irradiation time using dynamic multileaf collimation depends strongly on the nature of the desired dose distribution, and it is difficult to reduce this time to less than the sum of the irradiation times for all individual peak heights using dynamic leaf collimation [Svensson et al., Phys. Med. Biol. 39, 37-61 (1994)]. Therefore, the intensity modulation will considerably increase the total treatment time. A more cost-effective procedure for rapid intensity modulation is using narrow scanned photon, electron, and light ion beams in combination with fast multileaf collimator penumbra trimming. With this approach, the irradiation time is largely independent of the complexity of the desired intensity distribution and, in the case of photon beams, may even be shorter than with uniform beams. The intensity modulation is achieved primarily by scanning of a narrow elementary photon pencil beam generated by directing a narrow well focused high energy electron beam onto a thin bremsstrahlung target. In the present study, the design of a fast low-weight multileaf collimator that is capable of further sharpening the penumbra at the edge of the elementary scanned beam has been simulated, in order to minimize the dose or radiation response of healthy tissues. In the case of photon beams, such a multileaf collimator can be placed relatively close to the bremsstrahlung target to minimize its size. It can also be flat and thin, i.e., only 15-25 mm thick in the direction of the beam with edges made of tungsten or preferably osmium to optimize the sharpening of the penumbra. The low height of the collimator will minimize edge scatter from glancing incidence. The major portions of the collimator leafs can then be made of steel or even aluminum, so that the total weight of the multileaf collimator will be as low as 10 kg, which may even allow high-speed collimation in real time in synchrony with organ movements. To demonstrate the efficiency of this collimator design in combination with pencil beam scanning, optimal radiobiological treatments of an advanced cervix cancer were simulated. Different geometrical collimator designs were tested for bremsstrahlung, electron, and light ion beams. With a 10 mm half-width elementary scanned photon beam and a steel collimator with tungsten edges, it was possible to make as effective treatments as obtained with intensity modulated beams of full resolution, i.e., here 5 mm resolution in the fluence map. In combination with narrow pencil beam scanning, such a collimator may provide ideal delivery of photons, electrons, or light ions for radiation therapy synchronized to breathing and other organ motions. These high-energy photon and light ion beams may allow three-dimensional in vivo verification of delivery and thereby clinical implementation of the BioArt approach using Biologically Optimized three-dimensional in vivo predictive Assay based adaptive Radiation Therapy [Brahme, Acta Oncol. 42, 123-126 (2003)].
Investigation of cone-beam CT image quality trade-off for image-guided radiation therapy
NASA Astrophysics Data System (ADS)
Bian, Junguo; Sharp, Gregory C.; Park, Yang-Kyun; Ouyang, Jinsong; Bortfeld, Thomas; El Fakhri, Georges
2016-05-01
It is well-known that projections acquired over an angular range slightly over 180° (so-called short scan) are sufficient for fan-beam reconstruction. However, due to practical imaging conditions (projection data and reconstruction image discretization, physical factors, and data noise), the short-scan reconstructions may have different appearances and properties from the full-scan (scans over 360°) reconstructions. Nevertheless, short-scan configurations have been used in applications such as cone-beam CT (CBCT) for head-neck-cancer image-guided radiation therapy (IGRT) that only requires a small field of view due to the potential reduced imaging time and dose. In this work, we studied the image quality trade-off for full, short, and full/short scan configurations with both conventional filtered-backprojection (FBP) reconstruction and iterative reconstruction algorithms based on total-variation (TV) minimization for head-neck-cancer IGRT. Anthropomorphic and Catphan phantoms were scanned at different exposure levels with a clinical scanner used in IGRT. Both visualization- and numerical-metric-based evaluation studies were performed. The results indicate that the optimal exposure level and number of views are in the middle range for both FBP and TV-based iterative algorithms and the optimization is object-dependent and task-dependent. The optimal view numbers decrease with the total exposure levels for both FBP and TV-based algorithms. The results also indicate there are slight differences between FBP and TV-based iterative algorithms for the image quality trade-off: FBP seems to be more in favor of larger number of views while the TV-based algorithm is more robust to different data conditions (number of views and exposure levels) than the FBP algorithm. The studies can provide a general guideline for image-quality optimization for CBCT used in IGRT and other applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oh, S; Yea, J; Kang, M
Purpose: Respiratory gated radiation therapy (RGRT) is used to minimize the radiation dose to normal tissue in lung cancer patients. Determination of the optimal point in the respiratory phase of a patient is important in RGRT but it is not easy. The goal of the present study was to see if a visible guidance system is helpful in determining the optimal phase in respiratory gated therapy. Methods: The breathing signals of 23 lung cancer patients were recorded with a Real-time Position Management (RPM) respiratory gating system (Varian, USA). The patients underwent breathing training with our visible guidance system, after whichmore » their breathing signals were recorded during 5 min of free breathing and 5 min of guided breathing. The breathing signals recorded between 3 and 5 min before and after training were compared. We performed statistical analysis of the breathing signals to find the optimal duty cycle in guided breathing for RGRT. Results: The breathing signals aided by the visible guidance system had more regular cycles over time and smaller variations in the positions of the marker block than the free breathing signals. Of the 23 lung cancer patients, 19 showed statistically significant differences by time when the values obtained before and after breathing were compared (p < 0.05); 30% and 40% of the duty cycle, respectively, was determined to be the most effective, and the corresponding phases were 30 60% (duty cycle, 30%; p < 0.05) and 30 70% (duty cycle, 40%; p < 0.05). Conclusion: Respiratory regularity was significantly improved with the use of the RPM with our visible guiding system; therefore, it would help improve the accuracy and efficiency of RGRT.« less
Investigation of cone-beam CT image quality trade-off for image-guided radiation therapy.
Bian, Junguo; Sharp, Gregory C; Park, Yang-Kyun; Ouyang, Jinsong; Bortfeld, Thomas; El Fakhri, Georges
2016-05-07
It is well-known that projections acquired over an angular range slightly over 180° (so-called short scan) are sufficient for fan-beam reconstruction. However, due to practical imaging conditions (projection data and reconstruction image discretization, physical factors, and data noise), the short-scan reconstructions may have different appearances and properties from the full-scan (scans over 360°) reconstructions. Nevertheless, short-scan configurations have been used in applications such as cone-beam CT (CBCT) for head-neck-cancer image-guided radiation therapy (IGRT) that only requires a small field of view due to the potential reduced imaging time and dose. In this work, we studied the image quality trade-off for full, short, and full/short scan configurations with both conventional filtered-backprojection (FBP) reconstruction and iterative reconstruction algorithms based on total-variation (TV) minimization for head-neck-cancer IGRT. Anthropomorphic and Catphan phantoms were scanned at different exposure levels with a clinical scanner used in IGRT. Both visualization- and numerical-metric-based evaluation studies were performed. The results indicate that the optimal exposure level and number of views are in the middle range for both FBP and TV-based iterative algorithms and the optimization is object-dependent and task-dependent. The optimal view numbers decrease with the total exposure levels for both FBP and TV-based algorithms. The results also indicate there are slight differences between FBP and TV-based iterative algorithms for the image quality trade-off: FBP seems to be more in favor of larger number of views while the TV-based algorithm is more robust to different data conditions (number of views and exposure levels) than the FBP algorithm. The studies can provide a general guideline for image-quality optimization for CBCT used in IGRT and other applications.
Advancing Cancer Treatment Delivery - Role of Physics
NASA Astrophysics Data System (ADS)
Bortfeld, Thomas
Radiation treatment of localized tumors has evolved rapidly in recent decades, allowing radiation oncologists to deliver more focused treatments with significantly reduced side effects. One of the disruptive innovations led by physicists has been the development of intensity-modulated and image-guided radiation therapy (IMRT and IGRT), which has become the state of the art in radiation therapy with photons. At the next stage of the development, there is now growing interest in treating tumors with protons or heavier particles, which have the added physical benefit of the Bragg peak. However, proton and heavier particle therapy is available to fewer than 1% of the patients. The first reason for that is the higher cost and bigger size of particle therapy facilities. The second reason is uncertainty of the treatment delivery, which limits its accuracy and precision. To address the first point (higher cost), physicists are involved in developments to make the equipment much more compact and cheaper. Examples include superconducting accelerators, laser-accelerated accelerators, more compact ``gantries'' that rotate the beam around the patient, as well as other solutions to treat the patients form multiple directions of incidence. The uncertainties in positioning the Bragg peak in the patient are being addressed by in-vivo measurements of dose deposition, or surrogates thereof. Examples include the measurement of prompt gamma radiation produced by the proton beam as it traverses the patient. Positron-Emission-Tomography (PET) scans have also been used to measure the tissue activation by the proton beam. Finally, the measurement of sound waves produced by pulsed proton beams leading to rapid expansions of the irradiated tissue has recently been successfully pursued. After resolving the issue of aiming a treatment beam with high precision and low cost, such that the majority of the patients will benefit from it, one of the next challenges for physicists in medicine is to better identify the actual target of the treatment, and the dynamics of treating it optimally in a multi-modality approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Showalter, Timothy N., E-mail: tns3b@virginia.edu; Hegarty, Sarah E.; Division of Biostatistics, Department of Pharmacology and Experimental Therapeutics, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania
Purpose: Although the likelihood of radiation-related adverse events influences treatment decisions regarding radiation therapy after prostatectomy for eligible patients, the data available to inform decisions are limited. This study was designed to evaluate the genitourinary, gastrointestinal, and sexual adverse events associated with postprostatectomy radiation therapy and to assess the influence of radiation timing on the risk of adverse events. Methods: The Regione Emilia-Romagna Italian Longitudinal Health Care Utilization Database was queried to identify a cohort of men who received radical prostatectomy for prostate cancer during 2003 to 2009, including patients who received postprostatectomy radiation therapy. Patients with prior radiation therapymore » were excluded. Outcome measures were genitourinary, gastrointestinal, and sexual adverse events after prostatectomy. Rates of adverse events were compared between the cohorts who did and did not receive postoperative radiation therapy. Multivariable Cox proportional hazards models were developed for each class of adverse events, including models with radiation therapy as a time-varying covariate. Results: A total of 9876 men were included in the analyses: 2176 (22%) who received radiation therapy and 7700 (78%) treated with prostatectomy alone. In multivariable Cox proportional hazards models, the additional exposure to radiation therapy after prostatectomy was associated with increased rates of gastrointestinal (rate ratio [RR] 1.81; 95% confidence interval [CI] 1.44-2.27; P<.001) and urinary nonincontinence events (RR 1.83; 95% CI 1.83-2.80; P<.001) but not urinary incontinence events or erectile dysfunction. The addition of the time from prostatectomy to radiation therapy interaction term was not significant for any of the adverse event outcomes (P>.1 for all outcomes). Conclusion: Radiation therapy after prostatectomy is associated with an increase in gastrointestinal and genitourinary adverse events. However, the timing of radiation therapy did not influence the risk of radiation therapy–associated adverse events in this cohort, which contradicts the commonly held clinical tenet that delaying radiation therapy reduces the risk of adverse events.« less
NASA Astrophysics Data System (ADS)
Rylander, Marissa N.; Feng, Yusheng; Zhang, Yongjie; Bass, Jon; Stafford, Roger J.; Hazle, John D.; Diller, Kenneth R.
2006-07-01
Thermal therapy efficacy can be diminished due to heat shock protein (HSP) induction in regions of a tumor where temperatures are insufficient to coagulate proteins. HSP expression enhances tumor cell viability and imparts resistance to chemotherapy and radiation treatments, which are generally employed in conjunction with hyperthermia. Therefore, an understanding of the thermally induced HSP expression within the targeted tumor must be incorporated into the treatment plan to optimize the thermal dose delivery and permit prediction of the overall tissue response. A treatment planning computational model capable of predicting the temperature, HSP27 and HSP70 expression, and damage fraction distributions associated with laser heating in healthy prostate tissue and tumors is presented. Measured thermally induced HSP27 and HSP70 expression kinetics and injury data for normal and cancerous prostate cells and prostate tumors are employed to create the first HSP expression predictive model and formulate an Arrhenius damage model. The correlation coefficients between measured and model predicted temperature, HSP27, and HSP70 were 0.98, 0.99, and 0.99, respectively, confirming the accuracy of the model. Utilization of the treatment planning model in the design of prostate cancer thermal therapies can enable optimization of the treatment outcome by controlling HSP expression and injury.
NASA Astrophysics Data System (ADS)
Hardiyanti, Y.; Haekal, M.; Waris, A.; Haryanto, F.
2016-08-01
This research compares the quadratic optimization program on Intensity Modulated Radiation Therapy Treatment Planning (IMRTP) with the Computational Environment for Radiotherapy Research (CERR) software. We assumed that the number of beams used for the treatment planner was about 9 and 13 beams. The case used the energy of 6 MV with Source Skin Distance (SSD) of 100 cm from target volume. Dose calculation used Quadratic Infinite beam (QIB) from CERR. CERR was used in the comparison study between Gauss Primary threshold method and Gauss Primary exponential method. In the case of lung cancer, the threshold variation of 0.01, and 0.004 was used. The output of the dose was distributed using an analysis in the form of DVH from CERR. The maximum dose distributions obtained were on the target volume (PTV) Planning Target Volume, (CTV) Clinical Target Volume, (GTV) Gross Tumor Volume, liver, and skin. It was obtained that if the dose calculation method used exponential and the number of beam 9. When the dose calculation method used the threshold and the number of beam 13, the maximum dose distributions obtained were on the target volume PTV, GTV, heart, and skin.
NASA Astrophysics Data System (ADS)
Fallahnezhad, Somaye; Piryaei, Abbas; Tabeie, Faraj; Nazarian, Hamid; Darbandi, Hasan; Amini, Abdoldllah; Mostafavinia, Ataroalsadat; Ghorishi, Seyed Kamran; Jalalifirouzkouhi, Ali; Bayat, Mohammad
2016-09-01
The purpose of this study was to evaluate the influences of helium-neon (He-Ne) and infrared (IR) lasers on the viability and proliferation rate of healthy and ovariectomy-induced osteoporotic (OVX) bone marrow mesenchymal stem cells (BMMSCs) in vitro. MSCs harvested from the BM of healthy and OVX rats were culture expanded. He-Ne and IR lasers were applied three times at energy densities of 0.6, 1.2, and 2.4 J/cm2 for BMMSCs. BMMSCs viability and proliferation rate were evaluated by MTT assay on days 2, 4, 6, 14, and 21. The results showed that healthy BMMSCs responded optimally to 0.6 J/cm2 using an IR laser after three times of laser radiation. Moreover, it was found that OVX-BMMSCs responded optimally to 0.6 J/cm2 with He-Ne laser and one-time laser radiation. It is concluded that the low-level laser therapy (LLLT) effect depends on the physiological state of the BMMSCs, type of the laser, wavelength, and number of laser sessions. The biostimulation efficiency of LLLT also depends on the delivered energy density. LLLT can enhance the viability and proliferation rate of healthy and especially osteoporotic autologous BMMSCs, which could be very useful in regenerative medicine.
GPU-based ultra-fast dose calculation using a finite size pencil beam model.
Gu, Xuejun; Choi, Dongju; Men, Chunhua; Pan, Hubert; Majumdar, Amitava; Jiang, Steve B
2009-10-21
Online adaptive radiation therapy (ART) is an attractive concept that promises the ability to deliver an optimal treatment in response to the inter-fraction variability in patient anatomy. However, it has yet to be realized due to technical limitations. Fast dose deposit coefficient calculation is a critical component of the online planning process that is required for plan optimization of intensity-modulated radiation therapy (IMRT). Computer graphics processing units (GPUs) are well suited to provide the requisite fast performance for the data-parallel nature of dose calculation. In this work, we develop a dose calculation engine based on a finite-size pencil beam (FSPB) algorithm and a GPU parallel computing framework. The developed framework can accommodate any FSPB model. We test our implementation in the case of a water phantom and the case of a prostate cancer patient with varying beamlet and voxel sizes. All testing scenarios achieved speedup ranging from 200 to 400 times when using a NVIDIA Tesla C1060 card in comparison with a 2.27 GHz Intel Xeon CPU. The computational time for calculating dose deposition coefficients for a nine-field prostate IMRT plan with this new framework is less than 1 s. This indicates that the GPU-based FSPB algorithm is well suited for online re-planning for adaptive radiotherapy.
Paganetti, H; Jiang, H; Lee, S Y; Kooy, H M
2004-07-01
Monte Carlo dosimetry calculations are essential methods in radiation therapy. To take full advantage of this tool, the beam delivery system has to be simulated in detail and the initial beam parameters have to be known accurately. The modeling of the beam delivery system itself opens various areas where Monte Carlo calculations prove extremely helpful, such as for design and commissioning of a therapy facility as well as for quality assurance verification. The gantry treatment nozzles at the Northeast Proton Therapy Center (NPTC) at Massachusetts General Hospital (MGH) were modeled in detail using the GEANT4.5.2 Monte Carlo code. For this purpose, various novel solutions for simulating irregular shaped objects in the beam path, like contoured scatterers, patient apertures or patient compensators, were found. The four-dimensional, in time and space, simulation of moving parts, such as the modulator wheel, was implemented. Further, the appropriate physics models and cross sections for proton therapy applications were defined. We present comparisons between measured data and simulations. These show that by modeling the treatment nozzle with millimeter accuracy, it is possible to reproduce measured dose distributions with an accuracy in range and modulation width, in the case of a spread-out Bragg peak (SOBP), of better than 1 mm. The excellent agreement demonstrates that the simulations can even be used to generate beam data for commissioning treatment planning systems. The Monte Carlo nozzle model was used to study mechanical optimization in terms of scattered radiation and secondary radiation in the design of the nozzles. We present simulations on the neutron background. Further, the Monte Carlo calculations supported commissioning efforts in understanding the sensitivity of beam characteristics and how these influence the dose delivered. We present the sensitivity of dose distributions in water with respect to various beam parameters and geometrical misalignments. This allows the definition of tolerances for quality assurance and the design of quality assurance procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, Chad; Gomez, Daniel R.; Wang, Hongmei
Purpose: Radiation pneumonitis (RP) is an inflammatory response to radiation therapy (RT). We assessed the association between RP and white blood cell (WBC) count, an established metric of systemic inflammation, after RT for non-small cell lung cancer. Methods and Materials: We retrospectively analyzed 366 patients with non-small cell lung cancer who received ≥60 Gy as definitive therapy. The primary endpoint was whether WBC count after RT (defined as 2 weeks through 3 months after RT completion) was associated with grade ≥3 or grade ≥2 RP. Median lung volume receiving ≥20 Gy (V{sub 20}) was 31%, and post-RT WBC counts rangedmore » from 1.7 to 21.2 × 10{sup 3} WBCs/μL. Odds ratios (ORs) associating clinical variables and post-RT WBC counts with RP were calculated via logistic regression. A recursive-partitioning algorithm was used to define optimal post-RT WBC count cut points. Results: Post-RT WBC counts were significantly higher in patients with grade ≥3 RP than without (P<.05). Optimal cut points for post-RT WBC count were found to be 7.4 and 8.0 × 10{sup 3}/μL for grade ≥3 and ≥2 RP, respectively. Univariate analysis revealed significant associations between post-RT WBC count and grade ≥3 (n=46, OR=2.6, 95% confidence interval [CI] 1.4‒4.9, P=.003) and grade ≥2 RP (n=164, OR=2.0, 95% CI 1.2‒3.4, P=.01). This association held in a stepwise multivariate regression. Of note, V{sub 20} was found to be significantly associated with grade ≥2 RP (OR=2.2, 95% CI 1.2‒3.4, P=.01) and trended toward significance for grade ≥3 RP (OR=1.9, 95% CI 1.0-3.5, P=.06). Conclusions: Post-RT WBC counts were significantly and independently associated with RP and have potential utility as a diagnostic or predictive marker for this toxicity.« less
Evaluation of selection criteria for graduate students in radiation therapy.
Schneider-Kolsky, Michal; Wright, Caroline; Baird, Marilyn
2006-12-01
Selection of suitable students into graduate medical and specialist health professional courses can be difficult. Historically, selection of students was primarily based on prior academic performance. Recently, however, more emphasis has been placed on considering broader academic backgrounds and personal characteristics and attitudes of students, but no reliable measurement tool is available to predict student success and satisfaction with their choice of profession. The aim of this study was to survey practising radiation therapists in Australia to seek their opinions regarding suitable selection criteria for graduate entry radiation therapy (RT) students in order to optimize selection procedures for future applicants. Four hundred questionnaires were sent to nine RT centres in three states within Australia. All nine clinics participated in the survey and 189 questionnaires were returned. Results show that the majority of radiation therapists place a high level of importance upon a sound knowledge of physics and mathematics, as well as life experience, and agree that a visit to an RT clinic plus an interview comprise important components of the selection process. Humanities, psychology and a psychometric test were not viewed as essential entry requirements. Experienced radiation therapists placed less value on academic performance in the primary degree and were more likely to include an interview as a selection criterion than junior practitioners. Empathy for patients was identified as the most important personal attribute. It is thus recommended that not only cognitive but also personal skills be evaluated during the selection of prospective radiation therapists.
Online stochastic optimization of radiotherapy patient scheduling.
Legrain, Antoine; Fortin, Marie-Andrée; Lahrichi, Nadia; Rousseau, Louis-Martin
2015-06-01
The effective management of a cancer treatment facility for radiation therapy depends mainly on optimizing the use of the linear accelerators. In this project, we schedule patients on these machines taking into account their priority for treatment, the maximum waiting time before the first treatment, and the treatment duration. We collaborate with the Centre Intégré de Cancérologie de Laval to determine the best scheduling policy. Furthermore, we integrate the uncertainty related to the arrival of patients at the center. We develop a hybrid method combining stochastic optimization and online optimization to better meet the needs of central planning. We use information on the future arrivals of patients to provide an accurate picture of the expected utilization of resources. Results based on real data show that our method outperforms the policies typically used in treatment centers.
Optimization of Monte Carlo dose calculations: The interface problem
NASA Astrophysics Data System (ADS)
Soudentas, Edward
1998-05-01
High energy photon beams are widely used for radiation treatment of deep-seated tumors. The human body contains many types of interfaces between dissimilar materials that affect dose distribution in radiation therapy. Experimentally, significant radiation dose perturbations has been observed at such interfaces. The EGS4 Monte Carlo code was used to calculate dose perturbations at boundaries between dissimilar materials (such as bone/water) for 60Co and 6 MeV linear accelerator beams using a UNIX workstation. A simple test of the reliability of a random number generator was also developed. A systematic study of the adjustable parameters in EGS4 was performed in order to minimize calculational artifacts at boundaries. Calculations of dose perturbations at boundaries between different materials showed that there is a 12% increase in dose at water/bone interface, and a 44% increase in dose at water/copper interface. with the increase mainly due to electrons produced in water and backscattered from the high atomic number material. The dependence of the dose increase on the atomic number was also investigated. The clinically important case of using two parallel opposed beams for radiation therapy was investigated where increased doses at boundaries has been observed. The Monte Carlo calculations can provide accurate dosimetry data under conditions of electronic non-equilibrium at tissue interfaces.
Stereotactic multibeam radiation therapy system in a PACS environment
NASA Astrophysics Data System (ADS)
Fresne, Francoise; Le Gall, G.; Barillot, Christian; Gibaud, Bernard; Manens, Jean-Pierre; Toumoulin, Christine; Lemoine, Didier; Chenal, C.; Scarabin, Jean-Marie
1991-05-01
A Multibeam radiation therapy treatment is a non-invasive technique devoted to treat a lesion within the cerebral medium by focusing photon-beams on the same target from a high number of entrance points. We present here a computer assisted dosimetric planning procedure which includes: (1) an analysis module to define the target volume by using 2D and 3D displays, (2) a planing module to issue a treatment strategy including the dosimetric simulations and (3) a treatment module setting up the parameters to order the robotized treatment system (i.e. chair- framework, radiation unit machine). Another important feature of this system is its connection to the PACS system SIRENE settled in the University hospital of Rennes which makes possible the archiving and the communication of the multimodal images (CT, MRI, Angiography) used by this application. The corporate use of stereotactic methods and the multimodality imagery ensures spatial coherence and makes the target definition and the cognition of the structures environment more accurate. The dosimetric planning suited to the spatial reference (i.e. the stereotactic frame) guarantees an optimal distribution of the dose computed by an original 3D volumetric algorithm. The robotic approach of the treatment stage has consisted to design a computer driven chair-framework cluster to position the target volume at the radiation unit isocenter.
Optimizing Cone Beam Computed Tomography (CBCT) System for Image Guided Radiation Therapy
NASA Astrophysics Data System (ADS)
Park, Chun Joo
Cone Beam Computed Tomography (CBCT) system is the most widely used imaging device in image guided radiation therapy (IGRT), where set of 3D volumetric image of patient can be reconstructed to identify and correct position setup errors prior to the radiation treatment. This CBCT system can significantly improve precision of on-line setup errors of patient position and tumor target localization prior to the treatment. However, there are still a number of issues that needs to be investigated with CBCT system such as 1) progressively increasing defective pixels in imaging detectors by its frequent usage, 2) hazardous radiation exposure to patients during the CBCT imaging, 3) degradation of image quality due to patients' respiratory motion when CBCT is acquired and 4) unknown knowledge of certain anatomical features such as liver, due to lack of soft-tissue contrast which makes tumor motion verification challenging. In this dissertation, we explore on optimizing the use of cone beam computed tomography (CBCT) system under such circumstances. We begin by introducing general concept of IGRT. We then present the development of automated defective pixel detection algorithm for X-ray imagers that is used for CBCT imaging using wavelet analysis. We next investigate on developing fast and efficient low-dose volumetric reconstruction techniques which includes 1) fast digital tomosynthesis reconstruction using general-purpose graphics processing unit (GPGPU) programming and 2) fast low-dose CBCT image reconstruction based on the Gradient-Projection-Barzilai-Borwein formulation (GP-BB). We further developed two efficient approaches that could reduce the degradation of CBCT images from respiratory motion. First, we propose reconstructing four dimensional (4D) CBCT and DTS using respiratory signal extracted from fiducial markers implanted in liver. Second, novel motion-map constrained image reconstruction (MCIR) is proposed that allows reconstruction of high quality and high phase resolution 4DCBCT images with no more than the imaging dose used in a standard Free Breathing 3DCBCT (FB-3DCBCT) scan. Finally, we demonstrate a method to analyze motion characteristics of liver that are particularly important for image guided stereotactic body radiation therapy (IG-SBRT). It is anticipated that all the approaches proposed in this study, which are both technically and clinically feasible, will allow much improvement in IGRT process.
Nguyen, Timothy K; Senan, Suresh; Bradley, Jeffery D; Franks, Kevin; Giuliani, Meredith; Guckenberger, Matthias; Landis, Mark; Loo, Billy W; Louie, Alexander V; Onishi, Hiroshi; Schmidt, Heidi; Timmerman, Robert; Videtic, Gregory M M; Palma, David A
Imaging after stereotactic ablative radiation therapy (SABR) for early-stage non-small cell lung cancer can detect recurrences and second primary lung cancers; however, the optimal follow-up practice of these patients remains unclear. We sought to establish consensus recommendations for surveillance after SABR. International opinion leaders in thoracic radiation oncology and radiology were invited to participate (n = 31), with 11 accepting (9 radiation oncologists, 2 radiologists). Consensus-building was achieved using a 3-round Delphi process. Participants rated their agreement/disagreement with statements using a 5-point Likert scale. An a priori threshold of ≥75% agreement/disagreement was required for consensus. A 100% response rate was achieved and final consensus statements were approved by all participants. The consensus statements were: (1.1) thoracic computed tomography (CT) scans should be ordered routinely in follow-up; (1.2) if there is a suspicion for local recurrence (LR), fludeoxyglucose positron emission tomography/CT scans are strongly recommended. Otherwise, there is limited evidence to guide routine use of fludeoxyglucose positron emission tomography /CT; (1.3) CT imaging is not recommended at 6 weeks, but is recommended at months 3, 6, and 12 in year 1 and then every 6 months in year 2 and annually in years 3 through 5; (1.4) after 5 years, CT imaging should continue, although no consensus was reached regarding the frequency. (2.1) Response Evaluation Criteria in Solid Tumors 1.1 criteria are not sufficient for detecting LR; (2.2) a formal scoring system, informed by validated data, should be used to classify high-risk imaging features predictive of LR; (2.3) CT findings suspicious for LR include: infiltration into adjacent structures, bulging margins, sustained growth, mass-like growth, spherical growth, craniocaudal growth, and loss of air bronchograms. (3) Salvage therapy without pathologic confirmation of recurrence is acceptable if imaging findings are highly suspicious and a biopsy is not safe/feasible or if an attempted biopsy was nondiagnostic. These guidelines provide international expert consensus on areas of uncertainty in the management of early-stage non-small cell lung cancer patients after SABR. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
TH-AB-BRB-01: Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hristov, D.
2016-06-15
Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapymore » involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Yuan-Hong; Department of Radiation Oncology, Sun Yat-sen University Cancer Center, Guangzhou; Lin, Jun-Zhong
Purpose: Systemic failure remains the major challenge in management of locally advanced rectal cancer (LARC). To optimize the timing of neoadjuvant treatment and enhance systemic control, we initiated a phase 2 trial to evaluate a new strategy of neoadjuvant sandwich treatment, integrating induction chemotherapy, concurrent chemoradiation therapy, and consolidation chemotherapy. Here, we present preliminary results of this trial, reporting the tumor response, toxicities, and surgical complications. Methods and Materials: Fifty-one patients with LARC were enrolled, among which were two patients who were ineligible because of distant metastases before treatment. Patients were treated first with one cycle of induction chemotherapy consistingmore » of oxaliplatin, 130 mg/m² on day 1, with capecitabine, 1000 mg/m² twice daily for 14 days every 3 weeks (the XELOX regimen), followed by chemoradiation therapy, 50 Gy over 5 weeks, with the modified XELOX regimen (oxaliplatin 100 mg/m²), and then with another cycle of consolidation chemotherapy with the XELOX regimen. Surgery was performed 6 to 8 weeks after completion of radiation therapy. Tumor responses, toxicities, and surgical complications were recorded. Results: All but one patent completed the planned schedule of neoadjuvant sandwich treatment. Neither life-threatening blood count decrease nor febrile neutropenia were observed. Forty-five patents underwent optimal surgery with total mesorectal excision (TME). Four patients refused surgery because of clinically complete response. There was no perioperative mortality in this cohort. Five patients (11.1%) developed postoperative complications. Among the 45 patients who underwent TME, pathologic complete response (pCR), pCR or major regression, and at least moderate regression were achieved in 19 (42.2%), 37 (82.2%), and 44 patients (97.8%), respectively. Conclusions: Preliminary results suggest that the strategy of neoadjuvant sandwich treatment using XELOX regimen as induction, concomitant, and consolidation chemotherapy to the conventional radiation is well tolerated. The strategy is highly effective in terms of pCR and major regression, which warrants further investigation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lester-Coll, Nataniel H., E-mail: nataniel.lester-coll@yale.edu; Rutter, Charles E.; Bledsoe, Trevor J.
Introduction: Pulmonary oligometastases have conventionally been managed with surgery and/or systemic therapy. However, given concerns about the high cost of systemic therapy and improvements in local treatment of metastatic cancer, the optimal cost-effective management of these patients is unclear. Therefore, we sought to assess the cost-effectiveness of initial management strategies for pulmonary oligometastases. Methods and Materials: A cost-effectiveness analysis using a Markov modeling approach was used to compare average cumulative costs, quality adjusted life years (QALYs), and incremental cost-effectiveness ratios (ICERs) among 3 initial disease management strategies: video-assisted thoracic surgery (VATS) wedge resection, stereotactic body radiation therapy (SBRT), and systemicmore » therapy among 5 different cohorts of patient disease: (1) melanoma; (2) non-small cell lung cancer adenocarcinoma without an EGFR mutation (NSCLC AC); (3) NSCLC with an EGFR mutation (NSCLC EGFRm AC); (4) NSCLC squamous cell carcinoma (NSCLC SCC); and (5) colon cancer. One-way sensitivity analyses and probabilistic sensitivity analyses were performed to analyze uncertainty with regard to model parameters. Results: In the base case, SBRT was cost effective for melanoma, with costs/net QALYs of $467,787/0.85. In patients with NSCLC, the most cost-effective strategies were SBRT for AC ($156,725/0.80), paclitaxel/carboplatin for SCC ($123,799/0.48), and erlotinib for EGFRm AC ($147,091/1.90). Stereotactic body radiation therapy was marginally cost-effective for EGFRm AC compared to erlotinib with an incremental cost-effectiveness ratio of $126,303/QALY. For colon cancer, VATS wedge resection ($147,730/2.14) was the most cost-effective strategy. Variables with the greatest influence in the model were erlotinib-associated progression-free survival (EGFRm AC), toxicity (EGFRm AC), cost of SBRT (NSCLC SCC), and patient utilities (all histologies). Conclusions: Video-assisted thoracic surgery wedge resection or SBRT can be cost-effective in select patients with pulmonary oligometastases, depending on histology, efficacy, and tolerability of treatment and patient preferences.« less
Bassan, Renato; Masciulli, Arianna; Intermesoli, Tamara; Audisio, Ernesta; Rossi, Giuseppe; Pogliani, Enrico Maria; Cassibba, Vincenzo; Mattei, Daniele; Romani, Claudio; Cortelezzi, Agostino; Corti, Consuelo; Scattolin, Anna Maria; Spinelli, Orietta; Tosi, Manuela; Parolini, Margherita; Marmont, Filippo; Borlenghi, Erika; Fumagalli, Monica; Cortelazzo, Sergio; Gallamini, Andrea; Marfisi, Rosa Maria; Oldani, Elena; Rambaldi, Alessandro
2015-06-01
Developing optimal radiation-free central nervous system prophylaxis is a desirable goal in acute lymphoblastic leukemia, to avoid the long-term toxicity associated with cranial irradiation. In a randomized, phase II trial enrolling 145 adult patients, we compared intrathecal liposomal cytarabine (50 mg: 6/8 injections in B-/T-cell subsets, respectively) with intrathecal triple therapy (methotrexate/cytarabine/prednisone: 12 injections). Systemic therapy included methotrexate plus cytarabine or L-asparaginase courses, with methotrexate augmented to 2.5 and 5 g/m(2) in Philadelphia-negative B- and T-cell disease, respectively. The primary study objective was the comparative assessment of the risk/benefit ratio, combining the analysis of feasibility, toxicity and efficacy. In the liposomal cytarabine arm 17/71 patients (24%) developed grade 3-4 neurotoxicity compared to 2/74 (3%) in the triple therapy arm (P=0.0002), the median number of episodes of neurotoxicity of any grade was one per patient compared to zero, respectively (P=0.0001), and even though no permanent disabilities or deaths were registered, four patients (6%) discontinued intrathecal prophylaxis on account of these toxic side effects (P=0.06). Neurotoxicity worsened with liposomal cytarabine every 14 days (T-cell disease), and was improved by the adjunct of intrathecal dexamethasone. Two patients in the liposomal cytarabine arm suffered from a meningeal relapse (none with T-cell disease, only one after high-dose chemotherapy) compared to four in the triple therapy arm (1 with T-cell disease). While intrathecal liposomal cytarabine could contribute to improved, radiation-free central nervous system prophylaxis, the toxicity reported in this trial does not support its use at 50 mg and prompts the investigation of a lower dosage. (clinicaltrials.gov identifier: NCT-00795756). Copyright© Ferrata Storti Foundation.
Yang, Jie; Zhang, Pengcheng; Zhang, Liyuan; Shu, Huazhong; Li, Baosheng; Gui, Zhiguo
2017-01-01
In inverse treatment planning of intensity-modulated radiation therapy (IMRT), the objective function is typically the sum of the weighted sub-scores, where the weights indicate the importance of the sub-scores. To obtain a high-quality treatment plan, the planner manually adjusts the objective weights using a trial-and-error procedure until an acceptable plan is reached. In this work, a new particle swarm optimization (PSO) method which can adjust the weighting factors automatically was investigated to overcome the requirement of manual adjustment, thereby reducing the workload of the human planner and contributing to the development of a fully automated planning process. The proposed optimization method consists of three steps. (i) First, a swarm of weighting factors (i.e., particles) is initialized randomly in the search space, where each particle corresponds to a global objective function. (ii) Then, a plan optimization solver is employed to obtain the optimal solution for each particle, and the values of the evaluation functions used to determine the particle's location and the population global location for the PSO are calculated based on these results. (iii) Next, the weighting factors are updated based on the particle's location and the population global location. Step (ii) is performed alternately with step (iii) until the termination condition is reached. In this method, the evaluation function is a combination of several key points on the dose volume histograms. Furthermore, a perturbation strategy - the crossover and mutation operator hybrid approach - is employed to enhance the population diversity, and two arguments are applied to the evaluation function to improve the flexibility of the algorithm. In this study, the proposed method was used to develop IMRT treatment plans involving five unequally spaced 6MV photon beams for 10 prostate cancer cases. The proposed optimization algorithm yielded high-quality plans for all of the cases, without human planner intervention. A comparison of the results with the optimized solution obtained using a similar optimization model but with human planner intervention revealed that the proposed algorithm produced optimized plans superior to that developed using the manual plan. The proposed algorithm can generate admissible solutions within reasonable computational times and can be used to develop fully automated IMRT treatment planning methods, thus reducing human planners' workloads during iterative processes. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Recent insights in the therapeutic management of patients with gastric cancer.
de Mestier, Louis; Lardière-Deguelte, Sophie; Volet, Julien; Kianmanesh, Reza; Bouché, Olivier
2016-09-01
Gastric cancer remains frequent and one of the most lethal malignancies worldwide. In this article, we aimed to comprehensively review recent insights in the therapeutic management of gastric cancer, with focus on the surgical and perioperative management of resectable forms, and the latest advances regarding advanced diseases. Surgical improvements comprise the use of laparoscopic surgery including staging laparoscopy, a better definition of nodal dissection, and the development of hyperthermic intraperitoneal chemotherapy. The best individualized perioperative management should be assessed before curative-intent surgery for all patients and can consists in perioperative chemotherapy, adjuvant chemo-radiation therapy or adjuvant chemotherapy alone. The optimal timing and sequence of chemotherapy and radiation therapy with respect to surgery should be further explored. Patients with advanced gastric cancer have a poor prognosis. Nevertheless, they can benefit from doublet or triplet chemotherapy combination, including trastuzumab in HER2-positive patients. Upon progression, second-line therapy can be considered in patients with good performance status. Although anti-HER2 (trastuzumab) and anti-VEGFR (ramucirumab) may yield survival benefit, anti-EGFR and anti-HGFR therapies have failed to improve outcomes. Nevertheless, combination regimens containing cytotoxic drugs and targeted therapies should be further evaluated; keeping in mind that gastric cancer biology is different between Asia and the Western countries. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Magnetic resonance spectroscopic imaging for improved treatment planning of prostate cancer
NASA Astrophysics Data System (ADS)
Venugopal, Niranjan
Prostate cancer is the most common malignancy afflicting Canadian men in 2011. Physicians use digital rectal exams (DRE), blood tests for prostate specific antigen (PSA) and transrectal ultrasound (TRUS)-guided biopsies for the initial diagnosis of prostate cancer. None of these tests detail the spatial extent of prostate cancer - information critical for using new therapies that can target cancerous prostate. With an MRI technique called proton magnetic resonance spectroscopic imaging (1H-MRSI), biochemical analysis of the entire prostate can be done without the need for biopsy, providing detailed information beyond the non-specific changes in hardness felt by an experienced urologist in a DRE, the presence of PSA in blood, or the "blind-guidance" of TRUS-guided biopsy. A hindrance to acquiring high quality 1H-MRSI data comes from signal originating from fatty tissue surrounding prostate that tends to mask or distort signal from within the prostate, thus reducing the overall clinical usefulness of 1H-MRSI data. This thesis has three major areas of focus: 1) The development of an optimized 1H-MRSI technique, called conformal voxel magnetic resonance spectroscopy (CV-MRS), to deal the with removal of unwanted lipid contaminating artifacts at short and long echo times. 2) An in vivo human study to test the CV-MRS technique, including healthy volunteers and cancer patients scheduled for radical prostatectomy or radiation therapy. 3) A study to determine the efficacy of using the 1H-MRSI data for optimized radiation treatment planning using modern delivery techniques like intensity modulated radiation treatment. Data collected from the study using the optimized CV-MRS method show significantly reduced lipid contamination resulting in high quality spectra throughout the prostate. Combining the CV-MRS technique with spectral-spatial excitation further reduced lipid contamination and opened up the possibility of detecting metabolites with short T2 relaxation times. Results from the in vivo study were verified with post-histopathological data. Lastly, 1H-MRSI data was incorporated into the radiation treatment planning software and used to assess tumour control by escalating the radiation to prostate lesions that were identified by 1H-MRSI. In summary, this thesis demonstrates the clinical feasibility of using advanced spectroscopic imaging techniques for improved diagnosis and treatment of prostate cancer.
Radiation Therapy Intensification for Solid Tumors: A Systematic Review of Randomized Trials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamoah, Kosj; Showalter, Timothy N.; Ohri, Nitin, E-mail: ohri.nitin@gmail.com
Purpose: To systematically review the outcomes of randomized trials testing radiation therapy (RT) intensification, including both dose escalation and/or the use of altered fractionation, as a strategy to improve disease control for a number of malignancies. Methods and Materials: We performed a literature search to identify randomized trials testing RT intensification for cancers of the central nervous system, head and neck, breast, lung, esophagus, rectum, and prostate. Findings were described qualitatively. Where adequate data were available, pooled estimates for the effect of RT intensification on local control (LC) or overall survival (OS) were obtained using the inverse variance method. Results: Inmore » primary central nervous system tumors, esophageal cancer, and rectal cancer, randomized trials have not demonstrated that RT intensification improves clinical outcomes. In breast cancer and prostate cancer, dose escalation has been shown to improve LC or biochemical disease control but not OS. Radiation therapy intensification may improve LC and OS in head and neck and lung cancers, but these benefits have generally been limited to studies that did not incorporate concurrent chemotherapy. Conclusions: In randomized trials, the benefits of RT intensification have largely been restricted to trials in which concurrent chemotherapy was not used. Novel strategies to optimize the incorporation of RT in the multimodality treatment of solid tumors should be explored.« less
The presentation and outcomes of mucosal melanoma in 695 patients.
Konuthula, Neeraja; Khan, Mohemmed N; Parasher, Arjun; Del Signore, Anthony; Genden, Eric M; Govindaraj, Satish; Iloreta, Alfred M
2017-01-01
Most data on sinonasal mucosal melanoma come from small institutional studies, and therefore optimal treatment methods are not well understood. The purpose of this study was to analyze the association between treatment and survival in sinonasal mucosal melanoma. Six hundred ninety-five patients diagnosed with sinonasal mucosal melanoma between 2004 and 2010 were identified from the National Cancer Data Base. Treatment modalities and overall survival rates were determined. The 5-year overall survival was 21.7%, with a mean survival of 38.4 ± 1.7 months. The majority of patients were treated with surgery alone (31.5%) or surgery with adjuvant radiotherapy (41.4%). There was no statistical difference between survival with surgery alone and surgery with adjuvant radiation therapy (25.1% vs 25.1%, p = 0.93). Between the surgery and surgery-with-adjuvant-therapy groups, there was no difference in the number of patients with positive margins (p = 0.54), regional lymph node metastases at diagnosis (p = 0.55), morbidity scores (p = 0.58), insurance status (p = 0.13), age > 60 years (p = 0.24), or treatment at academic centers (p = 0.12). Based on this large review of patients with sinonasal mucosal melanoma, adjuvant radiation therapy may not provide a survival benefit as patients tended to do poorly regardless of adjuvant radiation status. © 2016 ARS-AAOA, LLC.
Donovan, Elysia K; Swaminath, Anand
2018-01-01
Stereotactic body radiation therapy (SBRT) has emerged as a new technology in radiotherapy delivery, allowing for potentially curative treatment in many patients previously felt not to be candidates for radical surgical resection of stage I non-small-cell lung cancer (NSCLC). Several studies have demonstrated very high local control rates using SBRT, and more recent data have suggested overall survival may approach that of surgery in operable patients. However, SBRT is not without unique toxicities, and the balance of toxicity, and effect on patient-reported quality of life need to be considered with respect to oncologic outcomes. We therefore aim to review SBRT in the context of important patient-related factors, including quality of life in several domains (and in comparison to other therapies such as conventional radiation, surgery, or no treatment). We will also describe scenarios in which SBRT may be reasonably offered (i.e. elderly patients and those with severe COPD), and where it may need to be approached with some caution due to increased risks of toxicity (i.e. tumor location, patients with interstitial lung disease). In total, we hope to characterize the physical, emotional, and functional consequences of SBRT, in relation to other management strategies, in order to aid the clinician in deciding whether SBRT is the optimal treatment choice for each patient with early stage NSCLC.
The Impact of Monte Carlo Dose Calculations on Intensity-Modulated Radiation Therapy
NASA Astrophysics Data System (ADS)
Siebers, J. V.; Keall, P. J.; Mohan, R.
The effect of dose calculation accuracy for IMRT was studied by comparing different dose calculation algorithms. A head and neck IMRT plan was optimized using a superposition dose calculation algorithm. Dose was re-computed for the optimized plan using both Monte Carlo and pencil beam dose calculation algorithms to generate patient and phantom dose distributions. Tumor control probabilities (TCP) and normal tissue complication probabilities (NTCP) were computed to estimate the plan outcome. For the treatment plan studied, Monte Carlo best reproduces phantom dose measurements, the TCP was slightly lower than the superposition and pencil beam results, and the NTCP values differed little.
Cancer and Radiation Therapy: Current Advances and Future Directions
Baskar, Rajamanickam; Lee, Kuo Ann; Yeo, Richard; Yeoh, Kheng-Wei
2012-01-01
In recent years remarkable progress has been made towards the understanding of proposed hallmarks of cancer development and treatment. However with its increasing incidence, the clinical management of cancer continues to be a challenge for the 21st century. Treatment modalities comprise of radiation therapy, surgery, chemotherapy, immunotherapy and hormonal therapy. Radiation therapy remains an important component of cancer treatment with approximately 50% of all cancer patients receiving radiation therapy during their course of illness; it contributes towards 40% of curative treatment for cancer. The main goal of radiation therapy is to deprive cancer cells of their multiplication (cell division) potential. Celebrating a century of advances since Marie Curie won her second Nobel Prize for her research into radium, 2011 has been designated the Year of Radiation therapy in the UK. Over the last 100 years, ongoing advances in the techniques of radiation treatment and progress made in understanding the biology of cancer cell responses to radiation will endeavor to increase the survival and reduce treatment side effects for cancer patients. In this review, principles, application and advances in radiation therapy with their biological end points are discussed. PMID:22408567
Cancer and radiation therapy: current advances and future directions.
Baskar, Rajamanickam; Lee, Kuo Ann; Yeo, Richard; Yeoh, Kheng-Wei
2012-01-01
In recent years remarkable progress has been made towards the understanding of proposed hallmarks of cancer development and treatment. However with its increasing incidence, the clinical management of cancer continues to be a challenge for the 21st century. Treatment modalities comprise of radiation therapy, surgery, chemotherapy, immunotherapy and hormonal therapy. Radiation therapy remains an important component of cancer treatment with approximately 50% of all cancer patients receiving radiation therapy during their course of illness; it contributes towards 40% of curative treatment for cancer. The main goal of radiation therapy is to deprive cancer cells of their multiplication (cell division) potential. Celebrating a century of advances since Marie Curie won her second Nobel Prize for her research into radium, 2011 has been designated the Year of Radiation therapy in the UK. Over the last 100 years, ongoing advances in the techniques of radiation treatment and progress made in understanding the biology of cancer cell responses to radiation will endeavor to increase the survival and reduce treatment side effects for cancer patients. In this review, principles, application and advances in radiation therapy with their biological end points are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barker, Christopher A., E-mail: barkerc@mskcc.org; Postow, Michael A.
Radiation therapy has long played a role in the management of melanoma. Recent advances have also demonstrated the efficacy of immunotherapy in the treatment of melanoma. Preclinical data suggest a biologic interaction between radiation therapy and immunotherapy. Several clinical studies corroborate these findings. This review will summarize the outcomes of studies reporting on patients with melanoma treated with a combination of radiation therapy and immunotherapy. Vaccine therapies often use irradiated melanoma cells, and may be enhanced by radiation therapy. The cytokines interferon-α and interleukin-2 have been combined with radiation therapy in several small studies, with some evidence suggesting increased toxicitymore » and/or efficacy. Ipilimumab, a monoclonal antibody which blocks cytotoxic T-lymphocyte antigen-4, has been combined with radiation therapy in several notable case studies and series. Finally, pilot studies of adoptive cell transfer have suggested that radiation therapy may improve the efficacy of treatment. The review will demonstrate that the combination of radiation therapy and immunotherapy has been reported in several notable case studies, series and clinical trials. These clinical results suggest interaction and the need for further study.« less
Duong, Jason; Ghanchi, Hammad; Miulli, Dan; Kahlon, Avneet
2018-04-17
Non-gestational choriocarcinoma (NGC) is a rare germ cell tumor, reported less than 0.6% of all gestational tumors, and has a poor prognosis when metastasized. NGC is even less reported with metastasis to the brain. Gestational choriocarcinoma (GC) when metastasized to the brain has a higher morbidity and mortality but has been known to be a chemosensitive and radiosensitive lesion, and NGC is chemoresistant with an even worse prognosis. Currently, there is no consensus for treatment for metastatic NGC to the brain. 66 year-old post-menopausal female presents with left upper extremity weakness more pronounced in her hand, and work up demonstrating a hemorrhagic lesion over the right frontal parietal lobe. Her metastatic work up was negative, leading to a craniotomy for resection of the mass. The pathology was consistent with metastatic gestational choriocarcinoma, non-gestational in origin. Because of its chemosensitive nature, reports of optimal metastatic GC treatment include radiation alone, chemotherapy without radiation, surgical resection, or combined multimodal therapy. No recommendations for NGC metastatic to the brain have been reported. We propose a systematic work up for hemorrhagic brain lesions to include the proposed imaging modalities and serum markers including β-hCG to aid with early diagnosis. With review of literature, we recommend surgical resection with adjuvant therapy for accessible symptomatic metastatic GC and NGC to the brain for optimal patient outcomes. Chemotherapy and radiation alone without surgical resection can be considered for asymptomatic GC metastasis to the brain. Copyright © 2018 Elsevier Inc. All rights reserved.
Multifunctional hollow gold nanoparticles designed for triple combination therapy and CT imaging.
Park, Jaesook; Park, Jin; Ju, Eun Jin; Park, Seok Soon; Choi, Jinhyang; Lee, Jae Hee; Lee, Kyoung Jin; Shin, Seol Hwa; Ko, Eun Jung; Park, Intae; Kim, Chulhee; Hwang, Jung Jin; Lee, Jung Shin; Song, Si Yeol; Jeong, Seong-Yun; Choi, Eun Kyung
2015-06-10
Hollow gold nanoparticles (HGNP) are a novel class of hybrid metal nanoparticles whose unique optical and morphological properties have spawned new applications including more effective cancer therapy. The shell thickness of HGNPs can tune the surface plasmon resonance to the near infrared light, resulting in photothermal ablation of tumors with optimal light penetration in tissue. The hollow cavity within a HGNP is able to accommodate a high payload of chemotherapeutic agents. They have also been used for enhancing radiosensitization in tumors during radiotherapy due to the high X-ray absorption capability of gold particles. However, no report has yet been published that utilize HGNPs for the triple combination therapy and CT imaging. In this study, we synthesized HGNPs which exhibit better response to radiation for therapy and imaging and demonstrated the effects of combined chemotherapy, thermal and radiotherapy. This combination strategy presented delayed tumor growth by 4.3-fold and reduced tumor's weight by 6.8-fold compared to control tumors. In addition, we demonstrated the feasibility of HGNP as a CT imaging agent. It is expected that translating these capabilities to human cancer patients could dramatically increase the antitumor effect and potentially overcome resistance to chemotherapeutic agents and radiation. Copyright © 2015 Elsevier B.V. All rights reserved.
TH-AB-BRB-04: Quality Assurance for Advanced Digital Linac Implementations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, V.
2016-06-15
Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapymore » involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.« less
TH-AB-BRB-00: Research Opportunities with Digital Linear Accelerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2016-06-15
Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapymore » involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.« less
Radiation Oncology Physics and Medical Physics Education
NASA Astrophysics Data System (ADS)
Bourland, Dan
2011-10-01
Medical physics, an applied field of physics, is the applications of physics in medicine. Medical physicists are essential professionals in contemporary healthcare, contributing primarily to the diagnosis and treatment of diseases through numerous inventions, advances, and improvements in medical imaging and cancer treatment. Clinical service, research, and teaching by medical physicists benefits thousands of patients and other individuals every day. This talk will cover three main topics. First, exciting current research and development areas in the medical physics sub-specialty of radiation oncology physics will be described, including advanced oncology imaging for treatment simulation, image-guided radiation therapy, and biologically-optimized radiation treatment. Challenges in patient safety in high-technology radiation treatments will be briefly reviewed. Second, the educational path to becoming a medical physicist will be reviewed, including undergraduate foundations, graduate training, residency, board certification, and career opportunities. Third, I will introduce the American Association of Physicists in Medicine (AAPM), which is the professional society that represents, advocates, and advances the field of medical physics (www.aapm.org).
21 CFR 892.5840 - Radiation therapy simulation system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiation therapy simulation system. 892.5840... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5840 Radiation therapy simulation system. (a) Identification. A radiation therapy simulation system is a fluoroscopic or radiographic x-ray...
21 CFR 892.5840 - Radiation therapy simulation system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiation therapy simulation system. 892.5840... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5840 Radiation therapy simulation system. (a) Identification. A radiation therapy simulation system is a fluoroscopic or radiographic x-ray...
Quasi-VMAT in high-grade glioma radiation therapy.
Fadda, G; Massazza, G; Zucca, S; Durzu, S; Meleddu, G; Possanzini, M; Farace, P
2013-05-01
To compare a quasi-volumetric modulated arc therapy (qVMAT) with three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) for the treatment of high-grade gliomas. The qVMAT technique is a fast method of radiation therapy in which multiple equispaced beams analogous to those in rotation therapy are radiated in succession. This study included 12 patients with a planning target volume (PTV) that overlapped at least one organ at risk (OAR). 3D-CRT was planned using 2-3 non-coplanar beams, whereby the field-in-field technique (FIF) was used to divide each field into 1-3 subfields to shield the OAR. The qVMAT strategy was planned with 15 equispaced beams and IMRT was planned using 9 beams with a total of 80 segments. Inverse planning for qVMAT and IMRT was performed by direct machine parameter optimization (DMPO) to deliver a homogenous dose distribution of 60 Gy within the PTV and simultaneously limit the dose received by the OARs to the recommended values. Finally, the effect of introducing a maximum dose objective (max. dose < 54 Gy) for a virtual OAR in the form of a 0.5 cm ring around the PTV was investigated. The qVMAT method gave rise to significantly improved PTV95% and conformity index (CI) values in comparison to 3D-CRT (PTV95% = 90.7 % vs. 82.0 %; CI = 0.79 vs. 0.74, respectively). A further improvement was achieved by IMRT (PTV95% = 94.4 %, CI = 0.78). In qVMAT and IMRT, the addition of a 0.5 cm ring around the PTV produced a significant increase in CI (0.87 and 0.88, respectively), but dosage homogeneity within the PTV was considerably reduced (PTV95% = 88.5 % and 92.3 %, respectively). The time required for qVMAT dose delivery was similar to that required using 3D-CRT. These findings suggest that qVMAT should be preferred to 3D-CRT for the treatment of high-grade gliomas. The qVMAT method could be applied in hospitals, for example, which have limited departmental resources and are not equipped with systems capable of VMAT delivery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Folkerts, MM; University of California San Diego, La Jolla, California; Long, T
Purpose: To provide a tool to generate large sets of realistic virtual patient geometries and beamlet doses for treatment optimization research. This tool enables countless studies exploring the fundamental interplay between patient geometry, objective functions, weight selections, and achievable dose distributions for various algorithms and modalities. Methods: Generating realistic virtual patient geometries requires a small set of real patient data. We developed a normalized patient shape model (PSM) which captures organ and target contours in a correspondence-preserving manner. Using PSM-processed data, we perform principal component analysis (PCA) to extract major modes of variation from the population. These PCA modes canmore » be shared without exposing patient information. The modes are re-combined with different weights to produce sets of realistic virtual patient contours. Because virtual patients lack imaging information, we developed a shape-based dose calculation (SBD) relying on the assumption that the region inside the body contour is water. SBD utilizes a 2D fluence-convolved scatter kernel, derived from Monte Carlo simulations, and can compute both full dose for a given set of fluence maps, or produce a dose matrix (dose per fluence pixel) for many modalities. Combining the shape model with SBD provides the data needed for treatment plan optimization research. Results: We used PSM to capture organ and target contours for 96 prostate cases, extracted the first 20 PCA modes, and generated 2048 virtual patient shapes by randomly sampling mode scores. Nearly half of the shapes were thrown out for failing anatomical checks, the remaining 1124 were used in computing dose matrices via SBD and a standard 7-beam protocol. As a proof of concept, and to generate data for later study, we performed fluence map optimization emphasizing PTV coverage. Conclusions: We successfully developed and tested a tool for creating customizable sets of virtual patients suitable for large-scale radiation therapy optimization research.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, J; Li, X; Ding, X
Purpose: We performed a retrospective dosimetric comparison study between the robustness optimized Intensity Modulated Proton Therapy (RO-IMPT), volumetric-modulated arc therapy (VMAT), and the non-coplanar 4? intensity modulated radiation therapy (IMRT). These methods represent the most advanced radiation treatment methods clinically available. We compare their dosimetric performance for head and neck cancer treatments with special focus on the OAR sparing near the tumor volumes. Methods: A total of 11 head and neck cases, which include 10 recurrent cases and one bilateral case, were selected for the study. Different dose levels were prescribed to tumor target depending on disease and location. Threemore » treatment plans were created on commercial TPS systems for a novel noncoplanar 4π method (20 beams), VMAT, and RO-IMPT technique (maximum 4 fields). The maximum patient positioning error was set to 3 mm and the maximum proton range uncertainty was set to 3% for the robustness optimization. Line dose profiles were investigated for OARs close to tumor volumes. Results: All three techniques achieved 98% coverage of the CTV target and most photon plans had less than 110% of the hot spots. The RO-IMPT plans show superior tumor dose homogeneity than 4? and VMAT plans. Although RO-IMPT has greater R50 dose spillage to the surrounding normal tissue than 4π and VMAT, the RO-IMPT plans demonstrate better or comparable OAR (parotid, mandible, carotid, oral cavity, pharynx, and etc.) sparing for structures closely abutting tumor targets. Conclusion: The RO-IMPT’s ability of OAR sparing is benchmarked against the C-arm linac based non-coplanar 4π technique and the standard VMAT method. RO-IMPT consistently shows better or comparable OAR sparing even for tissue structures closely abutting treatment target volume. RO-IMPT further reduces treatment uncertainty associated with proton therapy and delivers robust treatment plans to both unilateral and bilateral head and neck cancer patients with desirable treatment time.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nithiananthan, S.; Brock, K. K.; Daly, M. J.
2009-10-15
Purpose: The accuracy and convergence behavior of a variant of the Demons deformable registration algorithm were investigated for use in cone-beam CT (CBCT)-guided procedures of the head and neck. Online use of deformable registration for guidance of therapeutic procedures such as image-guided surgery or radiation therapy places trade-offs on accuracy and computational expense. This work describes a convergence criterion for Demons registration developed to balance these demands; the accuracy of a multiscale Demons implementation using this convergence criterion is quantified in CBCT images of the head and neck. Methods: Using an open-source ''symmetric'' Demons registration algorithm, a convergence criterion basedmore » on the change in the deformation field between iterations was developed to advance among multiple levels of a multiscale image pyramid in a manner that optimized accuracy and computation time. The convergence criterion was optimized in cadaver studies involving CBCT images acquired using a surgical C-arm prototype modified for 3D intraoperative imaging. CBCT-to-CBCT registration was performed and accuracy was quantified in terms of the normalized cross-correlation (NCC) and target registration error (TRE). The accuracy and robustness of the algorithm were then tested in clinical CBCT images of ten patients undergoing radiation therapy of the head and neck. Results: The cadaver model allowed optimization of the convergence factor and initial measurements of registration accuracy: Demons registration exhibited TRE=(0.8{+-}0.3) mm and NCC=0.99 in the cadaveric head compared to TRE=(2.6{+-}1.0) mm and NCC=0.93 with rigid registration. Similarly for the patient data, Demons registration gave mean TRE=(1.6{+-}0.9) mm compared to rigid registration TRE=(3.6{+-}1.9) mm, suggesting registration accuracy at or near the voxel size of the patient images (1x1x2 mm{sup 3}). The multiscale implementation based on optimal convergence criteria completed registration in 52 s for the cadaveric head and in an average time of 270 s for the larger FOV patient images. Conclusions: Appropriate selection of convergence and multiscale parameters in Demons registration was shown to reduce computational expense without sacrificing registration performance. For intraoperative CBCT imaging with deformable registration, the ability to perform accurate registration within the stringent time requirements of the operating environment could offer a useful clinical tool allowing integration of preoperative information while accurately reflecting changes in the patient anatomy. Similarly for CBCT-guided radiation therapy, fast accurate deformable registration could further augment high-precision treatment strategies.« less
Nithiananthan, S; Brock, K K; Daly, M J; Chan, H; Irish, J C; Siewerdsen, J H
2009-10-01
The accuracy and convergence behavior of a variant of the Demons deformable registration algorithm were investigated for use in cone-beam CT (CBCT)-guided procedures of the head and neck. Online use of deformable registration for guidance of therapeutic procedures such as image-guided surgery or radiation therapy places trade-offs on accuracy and computational expense. This work describes a convergence criterion for Demons registration developed to balance these demands; the accuracy of a multiscale Demons implementation using this convergence criterion is quantified in CBCT images of the head and neck. Using an open-source "symmetric" Demons registration algorithm, a convergence criterion based on the change in the deformation field between iterations was developed to advance among multiple levels of a multiscale image pyramid in a manner that optimized accuracy and computation time. The convergence criterion was optimized in cadaver studies involving CBCT images acquired using a surgical C-arm prototype modified for 3D intraoperative imaging. CBCT-to-CBCT registration was performed and accuracy was quantified in terms of the normalized cross-correlation (NCC) and target registration error (TRE). The accuracy and robustness of the algorithm were then tested in clinical CBCT images of ten patients undergoing radiation therapy of the head and neck. The cadaver model allowed optimization of the convergence factor and initial measurements of registration accuracy: Demons registration exhibited TRE=(0.8+/-0.3) mm and NCC =0.99 in the cadaveric head compared to TRE=(2.6+/-1.0) mm and NCC=0.93 with rigid registration. Similarly for the patient data, Demons registration gave mean TRE=(1.6+/-0.9) mm compared to rigid registration TRE=(3.6+/-1.9) mm, suggesting registration accuracy at or near the voxel size of the patient images (1 x 1 x 2 mm3). The multiscale implementation based on optimal convergence criteria completed registration in 52 s for the cadaveric head and in an average time of 270 s for the larger FOV patient images. Appropriate selection of convergence and multiscale parameters in Demons registration was shown to reduce computational expense without sacrificing registration performance. For intraoperative CBCT imaging with deformable registration, the ability to perform accurate registration within the stringent time requirements of the operating environment could offer a useful clinical tool allowing integration of preoperative information while accurately reflecting changes in the patient anatomy. Similarly for CBCT-guided radiation therapy, fast accurate deformable registration could further augment high-precision treatment strategies.
Nithiananthan, S.; Brock, K. K.; Daly, M. J.; Chan, H.; Irish, J. C.; Siewerdsen, J. H.
2009-01-01
Purpose: The accuracy and convergence behavior of a variant of the Demons deformable registration algorithm were investigated for use in cone-beam CT (CBCT)-guided procedures of the head and neck. Online use of deformable registration for guidance of therapeutic procedures such as image-guided surgery or radiation therapy places trade-offs on accuracy and computational expense. This work describes a convergence criterion for Demons registration developed to balance these demands; the accuracy of a multiscale Demons implementation using this convergence criterion is quantified in CBCT images of the head and neck. Methods: Using an open-source “symmetric” Demons registration algorithm, a convergence criterion based on the change in the deformation field between iterations was developed to advance among multiple levels of a multiscale image pyramid in a manner that optimized accuracy and computation time. The convergence criterion was optimized in cadaver studies involving CBCT images acquired using a surgical C-arm prototype modified for 3D intraoperative imaging. CBCT-to-CBCT registration was performed and accuracy was quantified in terms of the normalized cross-correlation (NCC) and target registration error (TRE). The accuracy and robustness of the algorithm were then tested in clinical CBCT images of ten patients undergoing radiation therapy of the head and neck. Results: The cadaver model allowed optimization of the convergence factor and initial measurements of registration accuracy: Demons registration exhibited TRE=(0.8±0.3) mm and NCC=0.99 in the cadaveric head compared to TRE=(2.6±1.0) mm and NCC=0.93 with rigid registration. Similarly for the patient data, Demons registration gave mean TRE=(1.6±0.9) mm compared to rigid registration TRE=(3.6±1.9) mm, suggesting registration accuracy at or near the voxel size of the patient images (1×1×2 mm3). The multiscale implementation based on optimal convergence criteria completed registration in 52 s for the cadaveric head and in an average time of 270 s for the larger FOV patient images. Conclusions: Appropriate selection of convergence and multiscale parameters in Demons registration was shown to reduce computational expense without sacrificing registration performance. For intraoperative CBCT imaging with deformable registration, the ability to perform accurate registration within the stringent time requirements of the operating environment could offer a useful clinical tool allowing integration of preoperative information while accurately reflecting changes in the patient anatomy. Similarly for CBCT-guided radiation therapy, fast accurate deformable registration could further augment high-precision treatment strategies. PMID:19928106
Stroke After Radiation Therapy for Head and Neck Cancer: What Is the Risk?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arthurs, Erin; Hanna, Timothy P.; Department of Oncology, Queen's University, Kingston, Ontario
Purpose: A retrospective population-based cohort study was conducted to determine the risk of ischemic stroke with respect to time, associated with curative radiation therapy in head and neck squamous cell carcinomas (HNSCC). Methods and Materials: On the basis of data from the Ontario Cancer Registry and regional cancer treatment centers, 14,069 patients were identified with diagnoses of squamous cell carcinoma of the oral cavity, larynx, and pharynx who were treated for cure between 1990 and 2010. Hazards of stroke and time to stroke were examined, accounting for the competing risk of death. Stroke risk factors identified through diagnostic and proceduralmore » administrative codes were adjusted for in the comparison between treatment regimens, which included surgery alone versus radiation therapy alone and surgery alone versus any exposure to radiation therapy. Results: Overall, 6% of patients experienced an ischemic stroke after treatment, with 5% experiencing a stroke after surgery, 8% after radiation therapy alone, and 6% after any exposure to radiation therapy. The cause-specific hazard ratios of ischemic stroke after radiation therapy alone and after any exposure to radiation therapy compared with surgery were 1.70 (95% confidence interval [CI]: 1.41-2.05) and 1.46 (95% CI: 1.23-1.73), respectively, after adjustment for stroke risk factors, patient factors, and disease-related factors. Conclusions: Radiation therapy was associated with an increased risk of ischemic stroke compared with surgery alone: for both radiation therapy alone and after all treatment modalities that included any radiation treatment were combined. Because of a shift toward a younger HNSCC patient population, our results speak to the need for adequate follow-up and survivorship care among patients who have been treated with radiation therapy. Advances in treatment that minimize chronic morbidity also require further evaluation.« less
WE-A-BRD-01: Innovation in Radiation Therapy Planning I: Knowledge Guided Treatment Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Q; Olsen, L
2014-06-15
Intensity modulated radiation therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) offer the capability of normal tissues and organs sparing. However, the exact amount of sparing is often unknown until the plan is complete. This lack of prior guidance has led to the iterative, trial and-error approach in current planning practice. Even with this effort the search for patient-specific optimal organ sparing is still strongly influenced by planner's experience. While experience generally helps in maximizing the dosimetric advantages of IMRT/VMAT, there have been several reports showing unnecessarily high degree of plan quality variability at individual institutions and amongst different institutions,more » even with a large amount of experience and the best available tools. Further, when physician and physicist evaluate a plan, the dosimetric quality of the plan is often compared with a standard protocol that ignores individual patient anatomy and tumor characteristic variations. In recent years, developments of knowledge models for clinical IMRT/VMAT planning guidance have shown promising clinical potentials. These knowledge models extract past expert clinical experience into mathematical models that predict dose sparing references at patient-specific level. For physicians and planners, these references provide objective values that reflect best achievable dosimetric constraints. For quality assurance, applying patient-specific dosimetry requirements will enable more quantitative and objective assessment of protocol compliance for complex IMRT planning. Learning Objectives: Modeling and representation of knowledge for knowledge-guided treatment planning. Demonstrations of knowledge-guided treatment planning with a few clinical caanatomical sites. Validation and evaluation of knowledge models for cost and quality effective standardization of plan optimization.« less
21 CFR 892.5710 - Radiation therapy beam-shaping block.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiation therapy beam-shaping block. 892.5710... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5710 Radiation therapy beam-shaping block. (a) Identification. A radiation therapy beam-shaping block is a device made of a highly...
21 CFR 892.5050 - Medical charged-particle radiation therapy system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical charged-particle radiation therapy system...-particle radiation therapy system. (a) Identification. A medical charged-particle radiation therapy system is a device that produces by acceleration high energy charged particles (e.g., electrons and protons...
21 CFR 892.5050 - Medical charged-particle radiation therapy system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical charged-particle radiation therapy system...-particle radiation therapy system. (a) Identification. A medical charged-particle radiation therapy system is a device that produces by acceleration high energy charged particles (e.g., electrons and protons...
21 CFR 892.5050 - Medical charged-particle radiation therapy system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical charged-particle radiation therapy system...-particle radiation therapy system. (a) Identification. A medical charged-particle radiation therapy system is a device that produces by acceleration high energy charged particles (e.g., electrons and protons...
Code of Federal Regulations, 2011 CFR
2011-10-01
... licensed as Radiographers, Nuclear Medicine Technologists, or Radiation Therapy Technologists. 2. Licenses... radiography, nuclear medicine technology, or radiation therapy technology. 2. Special eligibility to take the...-referenced examination in radiography, nuclear medicine technology, or radiation therapy technology shall be...
Code of Federal Regulations, 2012 CFR
2012-10-01
... licensed as Radiographers, Nuclear Medicine Technologists, or Radiation Therapy Technologists. 2. Licenses... radiography, nuclear medicine technology, or radiation therapy technology. 2. Special eligibility to take the...-referenced examination in radiography, nuclear medicine technology, or radiation therapy technology shall be...
Code of Federal Regulations, 2013 CFR
2013-10-01
... licensed as Radiographers, Nuclear Medicine Technologists, or Radiation Therapy Technologists. 2. Licenses... radiography, nuclear medicine technology, or radiation therapy technology. 2. Special eligibility to take the...-referenced examination in radiography, nuclear medicine technology, or radiation therapy technology shall be...
Code of Federal Regulations, 2014 CFR
2014-10-01
... licensed as Radiographers, Nuclear Medicine Technologists, or Radiation Therapy Technologists. 2. Licenses... radiography, nuclear medicine technology, or radiation therapy technology. 2. Special eligibility to take the...-referenced examination in radiography, nuclear medicine technology, or radiation therapy technology shall be...
21 CFR 892.5710 - Radiation therapy beam-shaping block.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiation therapy beam-shaping block. 892.5710... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5710 Radiation therapy beam-shaping block. (a) Identification. A radiation therapy beam-shaping block is a device made of a highly...
21 CFR 892.5710 - Radiation therapy beam-shaping block.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiation therapy beam-shaping block. 892.5710... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5710 Radiation therapy beam-shaping block. (a) Identification. A radiation therapy beam-shaping block is a device made of a highly...
21 CFR 892.5710 - Radiation therapy beam-shaping block.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiation therapy beam-shaping block. 892.5710... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5710 Radiation therapy beam-shaping block. (a) Identification. A radiation therapy beam-shaping block is a device made of a highly...
2008-06-01
cascade of tumor cell death in experimental tumors (4-6). However, survived tissues in a thin viable rim of tumor usually re-grow in spite of...changes monitored by MRI, optimum scheme of the combined radiation and CA4P will be designed and experimental treatment will be performed on the...CD31 Overlap Figure 4 CD 10 Task 2. Experimental tumor therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wan Chan Tseung, Hok Seum, E-mail: wanchantseung.hok@mayo.edu; Ma, Jiasen; Kreofsky, Cole R.
Purpose: Our aim is to demonstrate the feasibility of fast Monte Carlo (MC)–based inverse biological planning for the treatment of head and neck tumors in spot-scanning proton therapy. Methods and Materials: Recently, a fast and accurate graphics processor unit (GPU)–based MC simulation of proton transport was developed and used as the dose-calculation engine in a GPU-accelerated intensity modulated proton therapy (IMPT) optimizer. Besides dose, the MC can simultaneously score the dose-averaged linear energy transfer (LET{sub d}), which makes biological dose (BD) optimization possible. To convert from LET{sub d} to BD, a simple linear relation was assumed. By use of thismore » novel optimizer, inverse biological planning was applied to 4 patients, including 2 small and 1 large thyroid tumor targets, as well as 1 glioma case. To create these plans, constraints were placed to maintain the physical dose (PD) within 1.25 times the prescription while maximizing target BD. For comparison, conventional intensity modulated radiation therapy (IMRT) and IMPT plans were also created using Eclipse (Varian Medical Systems) in each case. The same critical-structure PD constraints were used for the IMRT, IMPT, and biologically optimized plans. The BD distributions for the IMPT plans were obtained through MC recalculations. Results: Compared with standard IMPT, the biologically optimal plans for patients with small tumor targets displayed a BD escalation that was around twice the PD increase. Dose sparing to critical structures was improved compared with both IMRT and IMPT. No significant BD increase could be achieved for the large thyroid tumor case and when the presence of critical structures mitigated the contribution of additional fields. The calculation of the biologically optimized plans can be completed in a clinically viable time (<30 minutes) on a small 24-GPU system. Conclusions: By exploiting GPU acceleration, MC-based, biologically optimized plans were created for small–tumor target patients. This optimizer will be used in an upcoming feasibility trial on LET{sub d} painting for radioresistant tumors.« less
TH-A-BRD-01: Radiation Biology for Radiation Therapy Physicists
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orton, C; Borras, C; Carlson, D
Mechanisms by which radiation kills cells and ways cell damage can be repaired will be reviewed. The radiobiological parameters of dose, fractionation, delivery time, dose rate, and LET will be discussed. The linear-quadratic model for cell survival for high and low dose rate treatments and the effect of repopulation will be presented and discussed. The rationale for various radiotherapy techniques such as conventional fractionation, hyperfractionation, hypofractionation, and low and high dose rate brachytherapy, including permanent implants, will be presented. The radiobiological principles underlying radiation protection guidelines and the different radiation dosimetry terms used in radiation biology and in radiation protectionmore » will be reviewed. Human data on radiation induced cancer, including increases in the risk of second cancers following radiation therapy, as well as data on radiation induced tissue reactions, such as cardiovascular effects, for follow up times up to 20–40 years, published by ICRP, NCRP and BEIR Committees, will be examined. The latest risk estimates per unit dose will be presented. Their adoption in recent radiation protection standards and guidelines and their impact on patient and workers safety in radiotherapy will be discussed. Biologically-guided radiotherapy (BGRT) provides a systematic method to derive prescription doses that integrate patient-specific information about tumor and normal tissue biology. Treatment individualization based on patient-specific biology requires the identification of biological objective functions to facilitate the design and comparison of competing treatment modalities. Biological objectives provide a more direct approach to plan optimization instead of relying solely on dose-based surrogates and can incorporate factors that alter radiation response, such as DNA repair, tumor hypoxia, and relative biological effectiveness. We review concepts motivating biological objectives and provide examples of how they might be used to address clinically relevant problems. Underlying assumptions and limitations of existing models and their proper application will be discussed. This multidisciplinary educational session combines the fundamentals of radiobiology for radiation therapy and radiation protection with the practical application of biophysical models for treatment planning and evaluation. Learning Objectives: To understand fractionation in teletherapy and dose rate techniques in brachytherapy. To understand how the linear-quadratic models the effect of radiobiological parameters for radiotherapy. To understand the radiobiological basis of radiation protection standards applied to radiotherapy. To distinguish between stochastic effects and tissue reactions. To learn how to apply concepts of biological effective dose and RBE-weighted dose and to incorporate biological factors that alter radiation response. To discuss clinical strategies to increase therapeutic ratio, i.e., maximize local control while minimizing the risk of acute and late normal tissue effects.« less
Enhancing radiotherapy with cyclooxygenase-2 enzyme inhibitors: a rational advance?
Choy, Hak; Milas, Luka
2003-10-01
Results of preclinical studies suggesting that the efficacy of molecular therapies is enhanced when they are combined with radiation have generated a surge of clinical trials combining these modalities. We reviewed the literature to identify the rationale and experimental foundation supporting the use of cyclooxygenase-2 (COX-2) inhibitors with standard radiotherapy regimens in current clinical trials. Radiation affects the ability of cells to divide and proliferate and induces the expression of genes involved in signaling pathways that promote cell survival or trigger cell death. Future advances in radiotherapy will hinge on understanding mechanisms by which radiation-induced transcription of genes governs cell death and survival, the selective control of this process, and the optimal approaches to combining this knowledge with existing therapeutic modalities. COX-2 is expressed in all stages of cancer, and in several cancers its overexpression is associated with poor prognosis. Evidence from clinical and preclinical studies indicates that COX-2-derived prostaglandins participate in carcinogenesis, inflammation, immune response suppression, apoptosis inhibition, angiogenesis, and tumor cell invasion and metastasis. Clinical trial results have demonstrated that selective inhibition of COX-2 can alter the development and the progression of cancer. In animal models, selective inhibition of COX-2 activity is associated with the enhanced radiation sensitivity of tumors without appreciably increasing the effects of radiation on normal tissue, and preclinical evidence suggests that the principal mechanism of radiation potentiation through selective COX-2 inhibition is the direct increase in cellular radiation sensitivity and the direct inhibition of tumor neovascularization. Results of current early-phase studies of non-small-cell lung, esophageal, cervical, and brain cancers will determine whether therapies that combine COX-2 inhibitors and radiation will enter randomized clinical trials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loveland-Jones, Catherine; Lin, Heather; Shen, Yu
Purpose: Although radiation therapy improves locoregional control and survival for inflammatory breast cancer (IBC), it is underused in this population. The purpose of this study was to identify variables associated with the underuse of postmastectomy radiation therapy (PMRT) for IBC. Methods and Materials: Using the 1998 to 2011 National Cancer Data Base, we identified 8273 women who underwent mastectomy for nonmetastatic IBC. We used logistic regression modeling to determine the demographic, tumor, and treatment variables associated with the underuse of PMRT. Results: Although the use of PMRT increased over time, a total of 30.3% of our cohort did not receivemore » PMRT. On multivariate analysis, variables associated with the underuse of PMRT for IBC included the following (all P<.05): Medicare insurance (odds ratio [OR] = 0.70), annual income <$34,999 (<$30,000: OR=0.79; $30,000-$34,999: OR=0.82), cN2 and cN0 disease (cN2: OR=0.71; cN0: OR=0.63), failure to receive chemotherapy and hormone therapy (chemotherapy: OR=0.15; hormone therapy: OR=0.35), treatment at lower-volume centers (OR=0.83), and treatment in the South and West (South: OR=0.73; West: OR=0.80). Greater distance between patient's residence and radiation facility was also associated with the underuse of PMRT (P=.0001). Conclusions: Although the use of PMRT for IBC has increased over time, it continues to be underused. Disparities related to a variety of variables impact which IBC patients receive PMRT. A concerted effort must be made to address these disparities in order to optimize the outcomes for IBC.« less
Crittenden, Marka R.; Baird, Jason; Friedman, David; Savage, Talicia; Uhde, Lauren; Alice, Alejandro; Cottam, Benjamin; Young, Kristina; Newell, Pippa; Nguyen, Cynthia; Bambina, Shelly; Kramer, Gwen; Akporiaye, Emmanuel; Malecka, Anna; Jackson, Andrew; Gough, Michael J.
2016-01-01
Radiation therapy provides a means to kill large numbers of cancer cells in a controlled location resulting in the release of tumor-specific antigens and endogenous adjuvants. However, by activating pathways involved in apoptotic cell recognition and phagocytosis, irradiated cancer cells engender suppressive phenotypes in macrophages. We demonstrate that the macrophage-specific phagocytic receptor, Mertk is upregulated in macrophages in the tumor following radiation therapy. Ligation of Mertk on macrophages results in anti-inflammatory cytokine responses via NF-kB p50 upregulation, which in turn limits tumor control following radiation therapy. We demonstrate that in immunogenic tumors, loss of Mertk is sufficient to permit tumor cure following radiation therapy. However, in poorly immunogenic tumors, TGFb inhibition is also required to result in tumor cure following radiation therapy. These data demonstrate that Mertk is a highly specific target whose absence permits tumor control in combination with radiation therapy. PMID:27602953
NASA Astrophysics Data System (ADS)
Gao, Wanbao; Raeside, David E.
1997-12-01
Dose distributions that result from treating a patient with orthovoltage beams are best determined with a treatment planning system that uses the Monte Carlo method, and such systems are not readily available. In the present work, the Monte Carlo method was used to develop a computer code for determining absorbed dose distributions in orthovoltage radiation therapy. The code was used in planning treatment of a patient with a neuroendocrine carcinoma of the maxillary sinus. Two lateral high-energy photon beams supplemented by an anterior orthovoltage photon beam were utilized in the treatment plan. For the clinical case and radiation beams considered, a reasonably uniform dose distribution
is achieved within the target volume, while the dose to the lens of each eye is 4 - 8% of the prescribed dose. Therefore, an orthovoltage photon beam, when properly filtered and optimally combined with megavoltage beams, can be effective in the treatment of cancers below the skin, providing that accurate treatment planning is carried out to establish with accuracy and precision the doses to critical structures.
Zhou, Lu; Zhou, Linghong; Zhang, Shuxu; Zhen, Xin; Yu, Hui; Zhang, Guoqian; Wang, Ruihao
2014-01-01
Deformable image registration (DIR) was widely used in radiation therapy, such as in automatic contour generation, dose accumulation, tumor growth or regression analysis. To achieve higher registration accuracy and faster convergence, an improved 'diffeomorphic demons' registration algorithm was proposed and validated. Based on Brox et al.'s gradient constancy assumption and Malis's efficient second-order minimization (ESM) algorithm, a grey value gradient similarity term and a transformation error term were added into the demons energy function, and a formula was derived to calculate the update of transformation field. The limited Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm was used to optimize the energy function so that the iteration number could be determined automatically. The proposed algorithm was validated using mathematically deformed images and physically deformed phantom images. Compared with the original 'diffeomorphic demons' algorithm, the registration method proposed achieve a higher precision and a faster convergence speed. Due to the influence of different scanning conditions in fractionated radiation, the density range of the treatment image and the planning image may be different. In such a case, the improved demons algorithm can achieve faster and more accurate radiotherapy.
Dolz, J; Kirişli, H A; Fechter, T; Karnitzki, S; Oehlke, O; Nestle, U; Vermandel, M; Massoptier, L
2016-05-01
Accurate delineation of organs at risk (OARs) on computed tomography (CT) image is required for radiation treatment planning (RTP). Manual delineation of OARs being time consuming and prone to high interobserver variability, many (semi-) automatic methods have been proposed. However, most of them are specific to a particular OAR. Here, an interactive computer-assisted system able to segment various OARs required for thoracic radiation therapy is introduced. Segmentation information (foreground and background seeds) is interactively added by the user in any of the three main orthogonal views of the CT volume and is subsequently propagated within the whole volume. The proposed method is based on the combination of watershed transformation and graph-cuts algorithm, which is used as a powerful optimization technique to minimize the energy function. The OARs considered for thoracic radiation therapy are the lungs, spinal cord, trachea, proximal bronchus tree, heart, and esophagus. The method was evaluated on multivendor CT datasets of 30 patients. Two radiation oncologists participated in the study and manual delineations from the original RTP were used as ground truth for evaluation. Delineation of the OARs obtained with the minimally interactive approach was approved to be usable for RTP in nearly 90% of the cases, excluding the esophagus, which segmentation was mostly rejected, thus leading to a gain of time ranging from 50% to 80% in RTP. Considering exclusively accepted cases, overall OARs, a Dice similarity coefficient higher than 0.7 and a Hausdorff distance below 10 mm with respect to the ground truth were achieved. In addition, the interobserver analysis did not highlight any statistically significant difference, at the exception of the segmentation of the heart, in terms of Hausdorff distance and volume difference. An interactive, accurate, fast, and easy-to-use computer-assisted system able to segment various OARs required for thoracic radiation therapy has been presented and clinically evaluated. The introduction of the proposed system in clinical routine may offer valuable new option to radiation oncologists in performing RTP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valicenti, Richard K., E-mail: Richard.valicenti@ucdmc.ucdavis.edu; Thompson, Ian; Albertsen, Peter
Purpose: The purpose of this guideline was to provide a clinical framework for the use of radiation therapy after radical prostatectomy as adjuvant or salvage therapy. Methods and Materials: A systematic literature review using PubMed, Embase, and Cochrane database was conducted to identify peer-reviewed publications relevant to the use of radiation therapy after prostatectomy. The review yielded 294 articles; these publications were used to create the evidence-based guideline statements. Additional guidance is provided as Clinical Principles when insufficient evidence existed. Results: Guideline statements are provided for patient counseling, use of radiation therapy in the adjuvant and salvage contexts, defining biochemicalmore » recurrence, and conducting a restaging evaluation. Conclusions: Physicians should offer adjuvant radiation therapy to patients with adverse pathologic findings at prostatectomy (ie, seminal vesicle invastion, positive surgical margins, extraprostatic extension) and salvage radiation therapy to patients with prostate-specific antigen (PSA) or local recurrence after prostatectomy in whom there is no evidence of distant metastatic disease. The offer of radiation therapy should be made in the context of a thoughtful discussion of possible short- and long-term side effects of radiation therapy as well as the potential benefits of preventing recurrence. The decision to administer radiation therapy should be made by the patient and the multidisciplinary treatment team with full consideration of the patient's history, values, preferences, quality of life, and functional status. The American Society for Radiation Oncology and American Urological Association websites show this guideline in its entirety, including the full literature review.« less
Role of Definitive Radiation Therapy in Carcinoma of Unknown Primary in the Abdomen and Pelvis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Patrick; Das, Prajnan; Varadhachary, Gauri R.
2012-04-01
Objectives: Carcinoma of unknown primary (CUP) in the abdomen and pelvis is a heterogeneous group of cancers with no standard treatment. Considered by many to be incurable, these patients are often treated with chemotherapy alone. In this study, we determined the effectiveness of radiation therapy in combination with chemotherapy in patients with CUP in the abdomen and pelvis. Patients and Methods: Medical records were reviewed for 37 patients with CUP treated with radiation therapy for disease located in the soft tissues and/or nodal basins of the abdomen and pelvis at University of Texas M.D. Anderson Cancer between 2002 and 2009.more » All patients underwent chemotherapy, either before or concurrent with radiation therapy. Patients were selected for radiation therapy on the basis of histologic type, disease extent, and prior therapy response. Twenty patients underwent definitive radiation therapy (defined as radiation therapy targeting all known disease sites with at least 45 Gy) and 17 patients underwent palliative radiation therapy. Only 6 patients had surgical resection of their disease. Patient and treatment characteristics were extracted and the endpoints of local disease control, progression-free survival (PFS), overall survival (OS), and treatment-related toxicity incidence were analyzed. Results: The 2-year PFS and OS rates for the entire cohort were 32% and 57%, respectively. However, in patients treated with definitive radiation therapy, the rates were 48% and 76%, and 7 patients lived more than 3 years after treatment with no evidence of disease progression. Nevertheless, radiation-associated toxicity was significant in this cohort, as 40% experienced Grade 2 or higher late toxicities. Conclusions: The use of definitive radiation therapy should be considered in selected patients with CUP in the soft tissues or nodal basins of the abdomen and pelvis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olszewski, Adam J., E-mail: adam_olszewski@brown.edu; Desai, Amrita
2014-03-01
Purpose: To determine the factors associated with the use of radiation therapy and associated survival outcomes in early-stage marginal zone lymphoma of the mucosa-associated lymphoid tissue (MALT). Methods and Materials: We extracted data on adult patients with stage I/II MALT lymphoma diagnoses between 1998 and 2010 recorded in the Surveillance, Epidemiology, and End Results (SEER) database. We studied factors associated with radiation therapy administration in a logistic regression model and described the cumulative incidence of lymphoma-related death (LRD) according to receipt of the treatment. The association of radiation therapy with survival was explored in multivariate models with adjustment for immortalmore » time bias. Results: Of the 7774 identified patients, 36% received radiation therapy as part of the initial course of treatment. Older patients; black or Hispanic men; white, Hispanic, and black women; and socioeconomically disadvantaged and underinsured patients had a significantly lower chance of receiving radiation therapy. Radiation therapy administration was associated with a lower chance of LRD in most sites. In cutaneous, ocular, and salivary MALT lymphomas, the 5-year estimate of LRD after radiation therapy was 0%. The association of radiation therapy with overall survival in different lymphoma sites was heterogeneous, and statistically significant in cutaneous (hazard ratio 0.45, P=.009) and ocular (hazard ratio 0.47, P<.0001) locations after multivariate adjustment. Conclusions: Demographic factors are associated with the use of radiation therapy in MALT lymphoma. Clinicians should be sensitive to those disparities because the administration of radiation therapy may be associated with improved survival, particularly in cutaneous and ocular lymphomas.« less
[Development of a Compared Software for Automatically Generated DVH in Eclipse TPS].
Xie, Zhao; Luo, Kelin; Zou, Lian; Hu, Jinyou
2016-03-01
This study is to automatically calculate the dose volume histogram(DVH) for the treatment plan, then to compare it with requirements of doctor's prescriptions. The scripting language Autohotkey and programming language C# were used to develop a compared software for automatically generated DVH in Eclipse TPS. This software is named Show Dose Volume Histogram (ShowDVH), which is composed of prescription documents generation, operation functions of DVH, software visualization and DVH compared report generation. Ten cases in different cancers have been separately selected, in Eclipse TPS 11.0 ShowDVH could not only automatically generate DVH reports but also accurately determine whether treatment plans meet the requirements of doctor’s prescriptions, then reports gave direction for setting optimization parameters of intensity modulated radiated therapy. The ShowDVH is an user-friendly and powerful software, and can automatically generated compared DVH reports fast in Eclipse TPS 11.0. With the help of ShowDVH, it greatly saves plan designing time and improves working efficiency of radiation therapy physicists.
Generalized field-splitting algorithms for optimal IMRT delivery efficiency.
Kamath, Srijit; Sahni, Sartaj; Li, Jonathan; Ranka, Sanjay; Palta, Jatinder
2007-09-21
Intensity-modulated radiation therapy (IMRT) uses radiation beams of varying intensities to deliver varying doses of radiation to different areas of the tissue. The use of IMRT has allowed the delivery of higher doses of radiation to the tumor and lower doses to the surrounding healthy tissue. It is not uncommon for head and neck tumors, for example, to have large treatment widths that are not deliverable using a single field. In such cases, the intensity matrix generated by the optimizer needs to be split into two or three matrices, each of which may be delivered using a single field. Existing field-splitting algorithms used the pre-specified arbitrary split line or region where the intensity matrix is split along a column, i.e., all rows of the matrix are split along the same column (with or without the overlapping of split fields, i.e., feathering). If three fields result, then the two splits are along the same two columns for all rows. In this paper we study the problem of splitting a large field into two or three subfields with the field width as the only constraint, allowing for an arbitrary overlap of the split fields, so that the total MU efficiency of delivering the split fields is maximized. Proof of optimality is provided for the proposed algorithm. An average decrease of 18.8% is found in the total MUs when compared to the split generated by a commercial treatment planning system and that of 10% is found in the total MUs when compared to the split generated by our previously published algorithm.
Job satisfaction among radiation therapy educators.
Swafford, Larry G; Legg, Jeffrey S
2007-01-01
Job satisfaction is one of the most consistent variables related to employee retention and is especially relevant considering the shortage of radiation therapists and radiation therapy educators in the United States. To investigate job satisfaction levels among radiation therapy educators certified by the American Registry of Radiologic Technologists and employed in programs accredited by the Joint Review Committee on Education in Radiologic Technology. The long form of the Minnesota Satisfaction Questionnaire (MSQ) was mailed to 158 radiation therapy educators to measure job satisfaction. Overall job satisfaction and subscales were calculated based on MSQ methodology. A total of 90 usable surveys were returned for a 56.9% response rate. With a "general satisfaction" score of 69.64, radiation therapy educators ranked in the lowest 25th percentile of the nondisabled norm scale for job satisfaction. Respondents reported higher degrees of job satisfaction on the moral values, social service and achievement subscales. Lower job satisfaction levels were associated with the company policies and practices, advancement and compensation subscales. Radiation therapy educators report low job satisfaction. Educational institutions must tailor recruitment and retention efforts to better reflect the positive aspects of being a radiation therapy educator. Furthermore, improving retention and recruitment efforts might help offset the current shortages of radiation therapy educators and, ultimately, clinical radiation therapists.
Datta, Niloy R; Samiei, Massoud; Bodis, Stephan
2014-07-01
Radiation therapy, a key component of cancer management, is required in more than half of new cancer patients, particularly in low- and middle-income countries (LMICs). The projected rise in cancer incidence over the next decades in LMICs will result in an increasing demand for radiation therapy services. Considering the present cancer incidence and that projected for 2020 (as listed in GLOBOCAN), we evaluated the current and anticipated needs for radiation therapy infrastructure and staffing by 2020 for each of the LMICs. Based on World Bank classification, 139 countries fall in the category of LMICs. Details of teletherapy, radiation oncologists, medical physicists, and radiation therapy technologists were available for 84 LMICs from the International Atomic Energy Agency-Directory of Radiotherapy Centres (IAEA-DIRAC) database. Present requirements and those for 2020 were estimated according to recommendations from the IAEA and European Society for Radiotherapy & Oncology (ESTRO-QUARTS). Only 4 of the 139 LMICs have the requisite number of teletherapy units, and 55 (39.5%) have no radiation therapy facilities at present. Patient access to radiation therapy in the remaining 80 LMICs ranges from 2.3% to 98.8% (median: 36.7%). By 2020, these 84 LMICs would additionally need 9169 teletherapy units, 12,149 radiation oncologists, 9915 medical physicists, and 29,140 radiation therapy technologists. Moreover, de novo radiation therapy facilities would have to be considered for those with no services. Twelve pragmatic steps are proposed for consideration at national and international levels to narrow the gap in radiation therapy access. Multipronged and coordinated action from all national and international stakeholders is required to develop realistic strategies to curb this impending global crisis. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Datta, Niloy R., E-mail: niloyranjan.datta@ksa.ch; Samiei, Massoud; Bodis, Stephan
2014-07-01
Purpose: Radiation therapy, a key component of cancer management, is required in more than half of new cancer patients, particularly in low- and middle-income countries (LMICs). The projected rise in cancer incidence over the next decades in LMICs will result in an increasing demand for radiation therapy services. Considering the present cancer incidence and that projected for 2020 (as listed in GLOBOCAN), we evaluated the current and anticipated needs for radiation therapy infrastructure and staffing by 2020 for each of the LMICs. Methods and Materials: Based on World Bank classification, 139 countries fall in the category of LMICs. Details ofmore » teletherapy, radiation oncologists, medical physicists, and radiation therapy technologists were available for 84 LMICs from the International Atomic Energy Agency–Directory of Radiotherapy Centres (IAEA-DIRAC) database. Present requirements and those for 2020 were estimated according to recommendations from the IAEA and European Society for Radiotherapy and Oncology (ESTRO-QUARTS). Results: Only 4 of the 139 LMICs have the requisite number of teletherapy units, and 55 (39.5%) have no radiation therapy facilities at present. Patient access to radiation therapy in the remaining 80 LMICs ranges from 2.3% to 98.8% (median: 36.7%). By 2020, these 84 LMICs would additionally need 9169 teletherapy units, 12,149 radiation oncologists, 9915 medical physicists, and 29,140 radiation therapy technologists. Moreover, de novo radiation therapy facilities would have to be considered for those with no services. Conclusions: Twelve pragmatic steps are proposed for consideration at national and international levels to narrow the gap in radiation therapy access. Multipronged and coordinated action from all national and international stakeholders is required to develop realistic strategies to curb this impending global crisis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shinohara, Eric T.; Mitra, Nandita; Guo Mengye
Purpose: Intrahepatic cholangiocarcinomas (IHC) are rare tumors for which large randomized studies regarding the use of radiation are not available. The purpose of this study was to examine the role of adjuvant and definitive radiation therapy in the treatment of IHC in a large group of patients. Methods and Materials: This is a retrospective analysis of 3,839 patients with IHC collected from the Surveillance, Epidemiology, and End Results (SEER) database. The primary endpoint was overall survival (OS). Results: Patients received either surgery alone (25%), radiation therapy alone (10%), surgery and adjuvant radiation therapy (7%) or no treatment (58%). The medianmore » age of the patient population was 73 years (range, 22-102 years); 52% of patients were male and 81% were Caucasian. Median OS was 11 (95% confidence interval [CI], 9-13), 6 (95% CI, 5-6), 7 (95% CI, 6-8), and 3 months for surgery and adjuvant radiation therapy, sugery alone, radiation therapy alone, and no treatment, respectively. The OS was significantly different between surgery alone and surgery and adjuvant radiation therapy (p = 0.014) and radiation therapy alone and no treatment (p < 0.0001). Use of surgery and adjuvant radiation therapy conferred the greatest benefit on OS (HR = 0.40; 95% CI, 0.34-0.47), followed by surgery alone (hazard ratio [HR], 0.49; 95% CI, 0.44-0.54) and radiation therapy alone (HR, 0.68; 95% CI, 0.59-0.77) compared with no treatment, on multivariate analysis. Propensity score adjusted hazard ratios (controlling for age, race/ethnicity, stage, and year of diagnosis) were also significant (surgery and adjuvant radiation therapy vs. surgery alone (HR, 0.82; 95% CI, 0.70-0.96); radiation therapy alone vs. no treatment (HR, 0.67; 95% CI, 0.58-0.76)). Conclusions: The study results suggest that adjuvant and definitive radiation treatment prolong survival, although cure rates remain low. Future studies should evaluate the addition of chemotherapy and biologics to the treatment of IHC.« less
Chu, Quyen D; Zhou, Meijiao; Peddi, Prakash; Medeiros, Kaelen L; Wu, Xiao-Cheng
2018-06-01
The Cancer and Leukemia Group B 9,343 demonstrated that postoperative radiation can be safely omitted in women ≥70 years who underwent breast-conserving therapy for clinical stage I (T1N0M0) estrogen receptor positive breast cancer treated with antihormonal therapy. Whether such results are observed in real-world population is unknown. In this hospital-based data, we report the survival outcomes of patients who received adjuvant radiation therapy versus those who did not. Using the National Cancer Data Base, we evaluated a cohort of 47,358 women with newly diagnosed breast cancer between 2004 and 2011 who underwent a lumpectomy and antihormonal therapy with the following criteria: age ≥70 years, clinical stage I, estrogen receptor positive, and negative margins. Patients were stratified into 2 groups: (1) radiation therapy and (2) no radiation therapy. Propensity score matching was used to compensate for differences in demographic and clinical characteristics of the patients. Univariate and multivariable survival analysis were employed to determine factors associated with overall survival. The 5-year overall survival after propensity score matching was 87.2% for radiation therapy and 79.4% for no radiation therapy (P < .0001). The median survival time was 113.7 months for radiation therapy and 105.2 months for no radiation therapy. After adjusting for sociodemographic and clinical factors, the risk of overall deaths was significantly higher for those not receiving radiation therapy (hazard ratio = 1.66; 95% confidence interval, 1.54-1.79). Other significant adjusted predictors (P < .05) of poor overall survival were, advanced age, comprehensive community cancer program, facility location, poorly differentiated tumor, and high comorbidity index. Patients who received radiation therapy had better survival outcomes than those who did not, revealing discordance between results of randomized trials and real-world setting. Copyright © 2018 Elsevier Inc. All rights reserved.
Locally advanced rectal cancer: time for precision therapeutics.
Weiser, Martin R; Zhang, Zhen; Schrag, Deborah
2015-01-01
The year 2015 marks the 30th anniversary of the publication of NSABP-R01, a landmark trial demonstrating the benefit of adding pelvic radiation to the treatment regimen for locally advanced rectal cancer with a resultant decrease in local recurrence from 25% to 16%. These results ushered in the era of multimodal therapy for rectal cancer, heralding modern treatment and changing the standard of care in the United States. We have seen many advances over the past 3 decades, including optimization of the administration and timing of radiation, widespread adoption of total mesorectal excision (TME), and the implementation of more effective systemic chemotherapy. The current standard is neoadjuvant chemoradiation with 5-fluorouracil (5-FU) and a radiosensitizer, TME, and adjuvant chemotherapy including 5-FU and oxaliplatin. The results of this regimen have been impressive, with a reported local recurrence rate of less than 10%. However, the rates of distant relapse remain 30% to 40%, indicating room for improvement. In addition, trimodality therapy is arduous and many patients are unable to complete the full course of treatment. In this article we discuss the current standard of care and alternative strategies that have evolved in an attempt to individualize therapy according to risk of recurrence.
NASA Astrophysics Data System (ADS)
Reavis, R. J.; Zielonka, Jason S.
1986-06-01
PACS literature to date has emphasized the needs of diagnostic imaging; however, the ability to acquire, manipulate, and display data derived from multiple imaging modalities is also vital in the practice of radiation oncology and radiation therapy planning (RTP). Radiographic or scintigraphic images for RTP must include specific spatial calibration data, as well as data relating image acquisition to anatomic localization within the patient. The digital nature of PACS images and displays allows the radiation oncologist to interactively assist in evaluating whether or not near-by structures are tumor-free. The radiation oncologist may also need to review nonradiographic diagnostic images (e.g., endoscopic images or pathology tissue specimens). Finally, it must be possible to take data such as isodose lines and superimpose them onto images relating the proposed therapy field to patient anatomy. Not only would this be useful for the radiation oncologist, but it would also provide information currently not easily available to the diagnostician and useful in subsequent diagnostic efforts. The three-dimensional (volumetric) data creation for RTP is not currently widespread because of the difficulties in converting images into a coherent, reliable and registered data set; this is the unique contribution of PACS. Software must be developed to permit creation of volumetric models based on data derived from both planar images and various tomographic modalities, including calibration and localizaton data for accurate image registration and scaling. This will permit positive definition of tumor volume by diagnosticians and the radiation oncologists as an initial portion of the therapy planning process. As a part of the underlying data structure for such systems, there must be some uniformity of image format between modalities and vendors; this has been adequately addressed by the Digital Imaging and Communications Interface Standard recently adopted by the American College of Radiology and the National Electrical Manufacturers' Association (ACR-NEMA). In addition, such standardization efforts must also incorporate the necessary calibration and coordinate data. This paper will examine some of the unique requirements for PACS (and PACS workstations)optimized for RTP. The assumption is made here that these are not independent, self-sufficient devices; rather, they are subsystems of a PACS network, capable of sharing certain resources.
Cheema, Parneet K; Menjak, Ines B; Winterton-Perks, Zoe; Raphael, Simon; Cheng, Susanna Y; Verma, Sunil; Muinuddin, Ahmad; Freedman, Ryan; Toor, Nevkeet; Perera, Joseph; Anaka, Matthew; Victor, J Charles
2017-02-01
Optimal first-line systemic therapy for patients with advanced nonsquamous (nonsq) non-small-cell lung cancer (NSCLC) requires confirmation of EGFR/ ALK status, which can delay treatment. We evaluated the impact of reflex testing, defined as pathologists initiating EGFR/ ALK testing at the time of diagnosis of nonsq NSCLC, on time to treatment (TTT). We conducted a retrospective review of patients with nonsq NSCLC with medical oncology consultation at Sunnybrook Odette Cancer Centre between March 18, 2010 and April 30, 2014. Data were compared during routine and reflex testing. TTT was defined as the interval between the first medical oncology visit with advanced NSCLC and the initiation of systemic therapy. A total of 306 patients were included (n = 232 for routine testing, n = 74 for reflex testing). There was a trend to improvement in median TTT with reflex testing (36 days [interquartile range {IQR}, 16 to 71 days v 26 days [IQR, 8 to 41 days], P = .071). Omitting patients with intentional delays in systemic therapy for low-volume disease, poor performance status, comorbidity management, and/or radiation therapy, median TTT improved (34 days [IQR, 15 to 67 days] v 22 days [IQR, 8 to 42 days], P = .049). Time to optimal first-line systemic therapy according to published guidelines improved (median, 36 days [IQR, 16 to 91 days] v 24 days [IQR, 8 to 43 days], P = .036). There was no impact on receipt of any first-line systemic therapy (55% v 59%, P = .66). The quality of biomarker testing improved, with fewer unsuccessful tests ( EGFR, 14% v 4%, P = .039; and ALK, 17% v 3%, P = .037). Reflex testing of EGFR/ ALK improved the time to optimal systemic therapy and the quality of biomarker testing for patients with advanced nonsq NSCLC.
[Highly quality-controlled radiation therapy].
Shirato, Hiroki
2005-04-01
Advanced radiation therapy for intracranial disease has focused on set-up accuracy for the past 15 years. However, quality control in the prescribed dose is actually as important as the tumor set-up in radiation therapy. Because of the complexity of the three-dimensional radiation treatment planning system in recent years, the highly quality-controlled prescription of the dose has now been reappraised as the mainstream to improve the treatment outcome of radiation therapy for intracranial disease. The Japanese Committee for Quality Control of Radiation Therapy has developed fundamental requirements such as a QC committee in each hospital, a medical physicist, dosimetrists (QC members), and an external audit.
Cancer treatment - mucositis; Cancer treatment - mouth pain; Cancer treatment - mouth sores; Chemotherapy - mucositis; Chemotherapy - mouth pain; Chemotherapy - mouth sores; Radiation therapy - mucositis; Radiation therapy - mouth pain; Radiation therapy - mouth ...
DOE Research Contributions to Radiation and Cancer Therapy
dropdown arrow Site Map A-Z Index Menu Synopsis DOE Research Contributions to Radiation and Cancer Therapy research has made many contributions to radiation and cancer therapy, including PEREGRINE and Boron Neutron planning radiation treatment for cancer patients. About 90 percent of radiation treatment patients receive
Optimal Use of Combined Modality Therapy in the Treatment of Esophageal Cancer.
Shaikh, Talha; Meyer, Joshua E; Horwitz, Eric M
2017-07-01
Esophageal cancer is associated with a poor prognosis with 5-year survival rates of approximately 15% to 20%. Although patients with early stage disease may adequately be treated with a single modality, combined therapy typically consisting of neoadjuvant chemoradiation followed by esophagectomy is being adopted increasingly in patients with locally advanced disease. In patients who are not surgical candidates, definitive chemoradiation is the preferred treatment approach. All patients with newly diagnosed esophageal cancer should be evaluated in the multidisciplinary setting by a surgeon, radiation oncologist, and medical oncologist owing to the importance of each specialty in the management of these patients. Copyright © 2017 Elsevier Inc. All rights reserved.
Music therapy CD creation for initial pediatric radiation therapy: a mixed methods analysis.
Barry, Philippa; O'Callaghan, Clare; Wheeler, Greg; Grocke, Denise
2010-01-01
A mixed methods research design was used to investigate the effects of a music therapy CD (MTCD) creation intervention on pediatric oncology patients' distress and coping during their first radiation therapy treatment. The music therapy method involved children creating a music CD using interactive computer-based music software, which was "remixed" by the music therapist-researcher to extend the musical material. Eleven pediatric radiation therapy outpatients aged 6 to 13 years were randomly assigned to either an experimental group, in which they could create a music CD prior to their initial treatment to listen to during radiation therapy, or to a standard care group. Quantitative and qualitative analyses generated multiple perceptions from the pediatric patients, parents, radiation therapy staff, and music therapist-researcher. Ratings of distress during initial radiation therapy treatment were low for all children. The comparison between the two groups found that 67% of the children in the standard care group used social withdrawal as a coping strategy, compared to 0% of the children in the music therapy group; this trend approached significance (p = 0.076). MTCD creation was a fun, engaging, and developmentally appropriate intervention for pediatric patients, which offered a positive experience and aided their use of effective coping strategies to meet the demands of their initial radiation therapy treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higgins, Kristin A., E-mail: kristin.higgins@emory.edu; Winship Cancer Institute, Emory University, Atlanta, Georgia; O'Connell, Kelli
Purpose: To analyze outcomes and predictors associated with proton radiation therapy for non-small cell lung cancer (NSCLC) in the National Cancer Database. Methods and Materials: The National Cancer Database was queried to capture patients with stage I-IV NSCLC treated with thoracic radiation from 2004 to 2012. A logistic regression model was used to determine the predictors for utilization of proton radiation therapy. The univariate and multivariable association with overall survival were assessed by Cox proportional hazards models along with log–rank tests. A propensity score matching method was implemented to balance baseline covariates and eliminate selection bias. Results: A total of 243,822more » patients (photon radiation therapy: 243,474; proton radiation therapy: 348) were included in the analysis. Patients in a ZIP code with a median income of <$46,000 per year were less likely to receive proton treatment, with the income cohort of $30,000 to $35,999 least likely to receive proton therapy (odds ratio 0.63 [95% confidence interval (CI) 0.44-0.90]; P=.011). On multivariate analysis of all patients, non-proton therapy was associated with significantly worse survival compared with proton therapy (hazard ratio 1.21 [95% CI 1.06-1.39]; P<.01). On propensity matched analysis, proton radiation therapy (n=309) was associated with better 5-year overall survival compared with non-proton radiation therapy (n=1549), 22% versus 16% (P=.025). For stage II and III patients, non-proton radiation therapy was associated with worse survival compared with proton radiation therapy (hazard ratio 1.35 [95% CI 1.10-1.64], P<.01). Conclusions: Thoracic radiation with protons is associated with better survival in this retrospective analysis; further validation in the randomized setting is needed to account for any imbalances in patient characteristics, including positron emission tomography–computed tomography staging.« less
MO-G-9A-01: Imaging Refresher for Standard of Care Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Labby, Z; Sensakovic, W; Hipp, E
2014-06-15
Imaging techniques and technology which were previously the domain of diagnostic medicine are becoming increasingly integrated and utilized in radiation therapy (RT) clinical practice. As such, there are a number of specific imaging topics that are highly applicable to modern radiation therapy physics. As imaging becomes more widely integrated into standard clinical radiation oncology practice, the impetus is on RT physicists to be informed and up-to-date on those imaging modalities relevant to the design and delivery of therapeutic radiation treatments. For example, knowing that, for a given situation, a fluid attenuated inversion recovery (FLAIR) image set is most likely whatmore » the physician would like to import and contour is helpful, but may not be sufficient to providing the best quality of care. Understanding the physics of how that pulse sequence works and why it is used could help assess its utility and determine if it is the optimal sequence for aiding in that specific clinical situation. It is thus important that clinical medical physicists be able to understand and explain the physics behind the imaging techniques used in all aspects of clinical radiation oncology practice. This session will provide the basic physics for a variety of imaging modalities for applications that are highly relevant to radiation oncology practice: computed tomography (CT) (including kV, MV, cone beam CT [CBCT], and 4DCT), positron emission tomography (PET)/CT, magnetic resonance imaging (MRI), and imaging specific to brachytherapy (including ultrasound and some brachytherapy specific topics in MR). For each unique modality, the image formation process will be reviewed, trade-offs between image quality and other factors (e.g. imaging time or radiation dose) will be clarified, and typically used cases for each modality will be introduced. The current and near-future uses of these modalities and techniques in radiation oncology clinical practice will also be discussed. Learning Objectives: To review the basic physical science principles of CT, PET, MR, and ultrasound imaging. To understand how the images are created, and present their specific role in patient management and treatment planning for therapeutic radiation (both external beam and brachytherapy). To discuss when and how each specific imaging modality is currently used in clinical practice, as well as how they may come to be used in the near future.« less
The Advantages of Collimator Optimization for Intensity Modulated Radiation Therapy
NASA Astrophysics Data System (ADS)
Doozan, Brian
The goal of this study was to improve dosimetry for pelvic, lung, head and neck, and other cancers sites with aspherical planning target volumes (PTV) using a new algorithm for collimator optimization for intensity modulated radiation therapy (IMRT) that minimizes the x-jaw gap (CAX) and the area of the jaws (CAA) for each treatment field. A retroactive study on the effects of collimator optimization of 20 patients was performed by comparing metric results for new collimator optimization techniques in Eclipse version 11.0. Keeping all other parameters equal, multiple plans are created using four collimator techniques: CA 0, all fields have collimators set to 0°, CAE, using the Eclipse collimator optimization, CAA, minimizing the area of the jaws around the PTV, and CAX, minimizing the x-jaw gap. The minimum area and the minimum x-jaw angles are found by evaluating each field beam's eye view of the PTV with ImageJ and finding the desired parameters with a custom script. The evaluation of the plans included the monitor units (MU), the maximum dose of the plan, the maximum dose to organs at risk (OAR), the conformity index (CI) and the number of fields that are calculated to split. Compared to the CA0 plans, the monitor units decreased on average by 6% for the CAX method with a p-value of 0.01 from an ANOVA test. The average maximum dose remained within 1.1% difference between all four methods with the lowest given by CAX. The maximum dose to the most at risk organ was best spared by the CAA method, which decreased by 0.62% compared to the CA0. Minimizing the x-jaws significantly reduced the number of split fields from 61 to 37. In every metric tested the CAX optimization produced comparable or superior results compared to the other three techniques. For aspherical PTVs, CAX on average reduced the number of split fields, lowered the maximum dose, minimized the dose to the surrounding OAR, and decreased the monitor units. This is achieved while maintaining the same control of the PTV.
Optimizing global liver function in radiation therapy treatment planning
NASA Astrophysics Data System (ADS)
Wu, Victor W.; Epelman, Marina A.; Wang, Hesheng; Romeijn, H. Edwin; Feng, Mary; Cao, Yue; Ten Haken, Randall K.; Matuszak, Martha M.
2016-09-01
Liver stereotactic body radiation therapy (SBRT) patients differ in both pre-treatment liver function (e.g. due to degree of cirrhosis and/or prior treatment) and radiosensitivity, leading to high variability in potential liver toxicity with similar doses. This work investigates three treatment planning optimization models that minimize risk of toxicity: two consider both voxel-based pre-treatment liver function and local-function-based radiosensitivity with dose; one considers only dose. Each model optimizes different objective functions (varying in complexity of capturing the influence of dose on liver function) subject to the same dose constraints and are tested on 2D synthesized and 3D clinical cases. The normal-liver-based objective functions are the linearized equivalent uniform dose (\\ell \\text{EUD} ) (conventional ‘\\ell \\text{EUD} model’), the so-called perfusion-weighted \\ell \\text{EUD} (\\text{fEUD} ) (proposed ‘fEUD model’), and post-treatment global liver function (GLF) (proposed ‘GLF model’), predicted by a new liver-perfusion-based dose-response model. The resulting \\ell \\text{EUD} , fEUD, and GLF plans delivering the same target \\ell \\text{EUD} are compared with respect to their post-treatment function and various dose-based metrics. Voxel-based portal venous liver perfusion, used as a measure of local function, is computed using DCE-MRI. In cases used in our experiments, the GLF plan preserves up to 4.6 % ≤ft(7.5 % \\right) more liver function than the fEUD (\\ell \\text{EUD} ) plan does in 2D cases, and up to 4.5 % ≤ft(5.6 % \\right) in 3D cases. The GLF and fEUD plans worsen in \\ell \\text{EUD} of functional liver on average by 1.0 Gy and 0.5 Gy in 2D and 3D cases, respectively. Liver perfusion information can be used during treatment planning to minimize the risk of toxicity by improving expected GLF; the degree of benefit varies with perfusion pattern. Although fEUD model optimization is computationally inexpensive and often achieves better GLF than \\ell \\text{EUD} model optimization does, the GLF model directly optimizes a more clinically relevant metric and can further improve fEUD plan quality.
Song, Ting; Li, Nan; Zarepisheh, Masoud; Li, Yongbao; Gautier, Quentin; Zhou, Linghong; Mell, Loren; Jiang, Steve; Cerviño, Laura
2016-01-01
Intensity-modulated radiation therapy (IMRT) currently plays an important role in radiotherapy, but its treatment plan quality can vary significantly among institutions and planners. Treatment plan quality control (QC) is a necessary component for individual clinics to ensure that patients receive treatments with high therapeutic gain ratios. The voxel-weighting factor-based plan re-optimization mechanism has been proved able to explore a larger Pareto surface (solution domain) and therefore increase the possibility of finding an optimal treatment plan. In this study, we incorporated additional modules into an in-house developed voxel weighting factor-based re-optimization algorithm, which was enhanced as a highly automated and accurate IMRT plan QC tool (TPS-QC tool). After importing an under-assessment plan, the TPS-QC tool was able to generate a QC report within 2 minutes. This QC report contains the plan quality determination as well as information supporting the determination. Finally, the IMRT plan quality can be controlled by approving quality-passed plans and replacing quality-failed plans using the TPS-QC tool. The feasibility and accuracy of the proposed TPS-QC tool were evaluated using 25 clinically approved cervical cancer patient IMRT plans and 5 manually created poor-quality IMRT plans. The results showed high consistency between the QC report quality determinations and the actual plan quality. In the 25 clinically approved cases that the TPS-QC tool identified as passed, a greater difference could be observed for dosimetric endpoints for organs at risk (OAR) than for planning target volume (PTV), implying that better dose sparing could be achieved in OAR than in PTV. In addition, the dose-volume histogram (DVH) curves of the TPS-QC tool re-optimized plans satisfied the dosimetric criteria more frequently than did the under-assessment plans. In addition, the criteria for unsatisfied dosimetric endpoints in the 5 poor-quality plans could typically be satisfied when the TPS-QC tool generated re-optimized plans without sacrificing other dosimetric endpoints. In addition to its feasibility and accuracy, the proposed TPS-QC tool is also user-friendly and easy to operate, both of which are necessary characteristics for clinical use.
Bauer-Nilsen, Kristine; Hill, Colin; Trifiletti, Daniel M; Libby, Bruce; Lash, Donna H; Lain, Melody; Christodoulou, Deborah; Hodge, Constance; Showalter, Timothy N
2018-01-01
To evaluate the delivery costs, using time-driven activity-based costing, and reimbursement for definitive radiation therapy for locally advanced cervical cancer. Process maps were created to represent each step of the radiation treatment process and included personnel, equipment, and consumable supplies used to deliver care. Personnel were interviewed to estimate time involved to deliver care. Salary data, equipment purchasing information, and facilities costs were also obtained. We defined the capacity cost rate (CCR) for each resource and then calculated the total cost of patient care according to CCR and time for each resource. Costs were compared with 2016 Medicare reimbursement and relative value units (RVUs). The total cost of radiation therapy for cervical cancer was $12,861.68, with personnel costs constituting 49.8%. Brachytherapy cost $8610.68 (66.9% of total) and consumed 423 minutes of attending radiation oncologist time (80.0% of total). External beam radiation therapy cost $4055.01 (31.5% of total). Personnel costs were higher for brachytherapy than for the sum of simulation and external beam radiation therapy delivery ($4798.73 vs $1404.72). A full radiation therapy course provides radiation oncologists 149.77 RVUs with intensity modulated radiation therapy or 135.90 RVUs with 3-dimensional conformal radiation therapy, with total reimbursement of $23,321.71 and $16,071.90, respectively. Attending time per RVU is approximately 4-fold higher for brachytherapy (5.68 minutes) than 3-dimensional conformal radiation therapy (1.63 minutes) or intensity modulated radiation therapy (1.32 minutes). Time-driven activity-based costing was used to calculate the total cost of definitive radiation therapy for cervical cancer, revealing that brachytherapy delivery and personnel resources constituted the majority of costs. However, current reimbursement policy does not reflect the increased attending physician effort and delivery costs of brachytherapy. We hypothesize that the significant discrepancy between treatment costs and physician effort versus reimbursement may be a potential driver of reported national trends toward poor compliance with brachytherapy, and we suggest re-evaluation of payment policies to incentivize quality care. Copyright © 2017 Elsevier Inc. All rights reserved.
[A recent trial of chemo-radiation with S-1 against gastric cancer].
Saikawa, Yoshiro; Kiyota, Tsuyoshi; Nakamura, Rieko; Wada, Norihito; Yoshida, Masashi; Kubota, Tetsuro; Kumai, Koichiro; Shigematsu, Naoyuki; Kubo, Atsushi; Kitajima, Masaki
2006-06-01
A recent development of novel anticancer agents like S-1, CPT-11 or taxanes has improved a therapeutic outcome for advanced gastric cancer, while conventional anticancer agents showed less anticancer effect against gastric cancer. The present main drug in Japan is S-1, which is easily used for outpatient with a high efficacy rate and low toxicity, also shows better effect in combination with other anticancer drugs than S-1 alone. In the present article, we demonstrated significant meaning of additional radiation therapy with anticancer drugs like S-1. With novel anticancer drugs like S-1, we will expose a clinical advantage and appropriateness for chemo-radiation therapy against gastric cancer discussed in the present references according to chemo-radiation therapy. Although chemo-radiation therapy has been recognized as one of the standard therapies for gastric cancer in Western countries, radiation therapy was selected in Japan for palliation therapy of recurrent disease or a terminal cancer to improve patients' QOL. On the other hand, we demonstrated in our trial of chemo-radiation therapy with S-1/low-dose CDDP/radiation (TSLDR), which was applied to initial treatment against highly advanced Stage IV gastric cancer and revealed the usefulness of the regimen in anticancer effect and toxicity. In addition, chemo-radiation therapy including novel anticancer agents like S-1 will be discussed based on various kinds of view points, expecting a better clinical outcome of multimodal therapies against advanced gastric cancer.
Retrospective study of orthovoltage radiation therapy for nasal tumors in 42 dogs.
Northrup, N C; Etue, S M; Ruslander, D M; Rassnick, K M; Hutto, D L; Bengtson, A; Rand, W; Moore, A S
2001-01-01
Megavoltage radiation therapy currently is the standard of care for dogs with nasal tumors. Some studies report that surgery and adjunctive orthovoltage radiation therapy result in longer control of these tumors than does megavoltage radiation therapy alone. This study reports less effective control of nasal tumors in dogs treated with surgery and orthovoltage radiation than previously observed, supporting the superiority of megavoltage radiation therapy for these tumors. In addition, this study suggests 2 new prognostic indicators for dogs with nasal tumors and describes toxicity associated with surgery and orthovoltage therapy. Forty-two dogs with nasal tumors were treated with surgical cytoreduction and 48 Gy orthovoltage radiation therapy administered in twelve 4-Gy fractions. Median survival was 7.4 months. One- and 2-year survival rates were 37% and 17%, respectively. Dogs with facial deformity had shorter survival than those without deformity (P = .005). Dogs with resolution of clinical signs after treatment had longer survival than those with chronic nasal signs (P = .0001). Acute radiation toxicity was moderate to severe for skin and eye and negligible for oral mucosa. Toxicity healed within 1 month after radiation therapy. Late toxicity was mild, but 70% of evaluable dogs experienced persistent ocular signs. Only 39% of dogs achieved a disease-free period.
External Beam Radiation Therapy for Cancer
External beam radiation therapy is used to treat many types of cancer. it is a local treatment, where a machine aims radiation at your cancer. Learn more about different types of external beam radiation therapy, and what to expect if you're receiving treatment.
NASA Astrophysics Data System (ADS)
Debebe, Senait A.; Franquiz, Juan; McGoron, Anthony J.
2015-03-01
Selective Internal Radiation Therapy (SIRT) is a common way to treat liver cancer that cannot be treated surgically. SIRT involves administration of Yttrium - 90 (90Y) microspheres via the hepatic artery after a diagnostic procedure using 99mTechnetium (Tc)-macroaggregated albumin (MAA) to detect extrahepatic shunting to the lung or the gastrointestinal tract. Accurate quantification of radionuclide administered to patients and radiation dose absorbed by different organs is of importance in SIRT. Accurate dosimetry for SIRT allows optimization of dose delivery to the target tumor and may allow for the ability to assess the efficacy of the treatment. In this study, we proposed a method that can efficiently estimate radiation absorbed dose from 90Y bremsstrahlung SPECT/CT images of liver and the surrounding organs. Bremsstrahlung radiation from 90Y was simulated using the Compton window of 99mTc (78keV at 57%). 99mTc images acquired at the photopeak energy window were used as a standard to examine the accuracy of dosimetry prediction by the simulated bremsstrahlung images. A Liqui-Phil abdominal phantom with liver, stomach and two tumor inserts was imaged using a Philips SPECT/CT scanner. The Dose Point Kernel convolution method was used to find the radiation absorbed dose at a voxel level for a three dimensional dose distribution. This method will allow for a complete estimate of the distribution of radiation absorbed dose by tumors, liver, stomach and other surrounding organs at the voxel level. The method provides a quantitative predictive method for SIRT treatment outcome and administered dose response for patients who undergo the treatment.
Carini, Fabrizio; Bucalo, Concetta; Saggese, Vito; Monai, Dario; Porcaro, Gianluca
2012-01-01
Summary Aims the assessment of the limit dose for the organs at risk in external radiotherapy is a fundamental step to guarantee an optimal risk-benefit ratio. The aim of this study was to assess, through contouring the single dental cavities, the absorbed radiation dose on irradiated alveolar bones during the treatment of cervico-facial tumours, so as to test the correlation between the absorbed dose of radiation at alveolar level and the level of individual surgical risk for osteonecrosis. Materials and methods we selected 45 out of 89 patients on the basis of different exclusion criteria. Nine of these patients showed evidence of osteoradionecrosis. The patients were treated either with 3D conformational radiation therapy (3D-CRT) or with intensity-modulated radiation therapy (IMRT), there after alveolar bones were contoured using computed axial tomography (CAT scans) carried out following oncological and dental treatment. The dose-volume histograms (DVH) were obtained on the basis of such data, which included those relating to the dental cavities in addition to those inherent to the tumours and the organs at risk. Results all patients, irrespective of type of treatment, received an average of 60 to 70 grays in 30/35 sittings. The patients treated with IMRT showed higher variation in absorbed radiation dose than those treated with 3D-CRT. The alveolar encirclement allowed the assessment of the absorbed radiation dose, and consequently it also allowed to assess the individual surgical risk for osteonecrosis in patients with head and neck tumours who underwent radiography treatment. Conclusions the study of DVH allows the assessment of limit dose and the detection of the areas at greater risk for osteoradionecrosis before dental surgery. PMID:23285316
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Fangyao; Vishwanath, Karthik; Salama, Joseph K.
Purpose: To test whether oxygenation kinetics correlate with the likelihood for local tumor control after fractionated radiation therapy. Methods and Materials: We used diffuse reflectance spectroscopy to noninvasively measure tumor vascular oxygenation and total hemoglobin concentration associated with radiation therapy of 5 daily fractions (7.5, 9, or 13.5 Gy/d) in FaDu xenografts. Spectroscopy measurements were obtained immediately before each daily radiation fraction and during the week after radiation therapy. Oxygen saturation and total hemoglobin concentration were computed using an inverse Monte Carlo model. Results: First, oxygenation kinetics during and after radiation therapy, but before tumor volumes changed, were associated with localmore » tumor control. Locally controlled tumors exhibited significantly faster increases in oxygenation after radiation therapy (days 12-15) compared with tumors that recurred locally. Second, within the group of tumors that recurred, faster increases in oxygenation during radiation therapy (day 3-5 interval) were correlated with earlier recurrence times. An area of 0.74 under the receiver operating characteristic curve was achieved when classifying the local control tumors from all irradiated tumors using the oxygen kinetics with a logistic regression model. Third, the rate of increase in oxygenation was radiation dose dependent. Radiation doses ≤9.5 Gy/d did not initiate an increase in oxygenation, whereas 13.5 Gy/d triggered significant increases in oxygenation during and after radiation therapy. Conclusions: Additional confirmation is required in other tumor models, but these results suggest that monitoring tumor oxygenation kinetics could aid in the prediction of local tumor control after radiation therapy.« less
Cardio-oncology/onco-cardiology.
Hong, Robert A; Iimura, Takeshi; Sumida, Kenneth N; Eager, Robert M
2010-12-01
An understanding of onco-cardiology or cardio-oncology is critical for the effective care of cancer patients. Virtually all antineoplastic agents are associated with cardiotoxicity, which can be divided into 5 categories: direct cytotoxic effects of chemotherapy and associated cardiac systolic dysfunction, cardiac ischemia, arrhythmias, pericarditis, and chemotherapy-induced repolarization abnormalities. Radiation therapy can also lead to coronary artery disease and fibrotic changes to the valves, pericardium, and myocardium. All patients being considered for chemotherapy, especially those who have prior cardiac history, should undergo detailed cardiovascular evaluation to optimize the treatment. Serial assessment of left ventricular systolic function and cardiac biomarkers might also be considered in selected patient populations. Cardiotoxic effects of chemotherapy might be decreased by the concurrent use of angiotensin-converting enzyme inhibitors, angiotensin receptor blockers, or beta-blockers. Antiplatelet or anticoagulation therapy might be considered in patients with a potential hypercoagulable state associated with chemotherapy or cancer. Open dialogue between both cardiologists and oncologists will be required for optimal patient care. Copyright © 2010 Wiley Periodicals, Inc.
Radenkovic, Dina; Kobayashi, Hisataka; Remsey-Semmelweis, Ernö; Seifalian, Alexander M
2016-08-01
Breast cancer is the most common cancer in the world. Sentinel lymph node (SLN) biopsy is used for staging of axillary lymph nodes. Organic dyes and radiocolloid are currently used for SLN mapping, but expose patients to ionizing radiation, are unstable during surgery and cause local tissue damage. Quantum dots (QD) could be used for SLN mapping without the need for biopsy. Surgical resection of the primary tumor is the optimal treatment for early-diagnosed breast cancer, but due to difficulties in defining tumor margins, cancer cells often remain leading to reoccurrences. Functionalized QD could be used for image-guided tumor resection to allow visualization of cancer cells. Near Infrared QD are photostable and have improved deep tissue penetration. Slow elimination of QD raises concerns of potential accumulation. Nevertheless, promising findings with cadmium-free QD in recent in vivo studies and first in-human trial suggest huge potential for cancer diagnostic and therapy. Copyright © 2016 Elsevier Inc. All rights reserved.
Hall, William A; Bergom, Carmen; Thompson, Reid F; Baschnagel, Andrew M; Vijayakumar, Srinivasan; Willers, Henning; Li, X Allen; Schultz, Christopher J; Wilson, George D; West, Catharine M L; Capala, Jacek; Coleman, C Norman; Torres-Roca, Javier F; Weidhaas, Joanne; Feng, Felix Y
2018-06-01
To summarize important talking points from a 2016 symposium focusing on real-world challenges to advancing precision medicine in radiation oncology, and to help radiation oncologists navigate the practical challenges of precision, radiation oncology. The American Society for Radiation Oncology, American Association of Physicists in Medicine, and National Cancer Institute cosponsored a meeting on precision medicine in radiation oncology. In June 2016 numerous scientists, clinicians, and physicists convened at the National Institutes of Health to discuss challenges and future directions toward personalized radiation therapy. Various breakout sessions were held to discuss particular components and approaches to the implementation of personalized radiation oncology. This article summarizes the genomically guided radiation therapy breakout session. A summary of existing genomic data enabling personalized radiation therapy, ongoing clinical trials, current challenges, and future directions was collected. The group attempted to provide both a current overview of data that radiation oncologists could use to personalize therapy, along with data that are anticipated in the coming years. It seems apparent from the provided review that a considerable opportunity exists to truly bring genomically guided radiation therapy into clinical reality. Genomically guided radiation therapy is a necessity that must be embraced in the coming years. Incorporating these data into treatment recommendations will provide radiation oncologists with a substantial opportunity to improve outcomes for numerous cancer patients. More research focused on this topic is needed to bring genomic signatures into routine standard of care. Published by Elsevier Inc.
Leonard, Sarah; O'Donovan, Anita
Minimizing errors and improving patient safety has gained prominence worldwide in high-risk disciplines such as radiation therapy. Patient safety culture has been identified as an important factor in reducing the incidence of adverse events and improving patient safety in the health care setting. The aim of distributing the Hospital Survey on Patient Safety Culture (HSPSC) to radiation therapy departments worldwide was to assess the current status of safety culture, identify areas for improvement and areas that excel, examine factors that influence safety culture, and raise staff awareness. The safety culture in radiation therapy departments worldwide was evaluated by distributing the HSPSC. A total of 266 participants were recruited from radiation therapy departments and included radiation oncologists, radiation therapists, physicists, and dosimetrists. The positive percent scores for the 12 dimensions of the HSPSC varied from 50% to 79%. The highest composite score among the 12 dimensions was teamwork within units; the lowest composite score was handoffs and transitions. The results indicated that health care professionals in radiation therapy departments felt positively toward patient safety. The HSPSC was successfully applied to radiation therapy departments and provided valuable insight into areas of potential improvement such as teamwork across units, staffing, and handoffs and transitions. Managers and policy makers in radiation therapy may use this assessment tool for focused improvement efforts toward patient safety culture. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
TU-G-201-00: Imaging Equipment Specification and Selection in Radiation Oncology Departments
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, andmore » potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.« less
Agarwalla, Anant; Small, Aaron J; Mendelson, Aaron H; Scott, Frank I; Kochman, Michael L
2015-07-01
Radiation therapy for head, neck, and esophageal cancer can result in esophageal strictures that may be difficult to manage. Radiation-induced esophageal strictures often require repeat dilation to obtain relief of dysphagia. This study aimed to determine the long-term clinical success and rates of recurrent and refractory stenosis in patients with radiation-induced strictures undergoing dilation. Retrospective cohort study of patients with radiation-induced strictures who underwent endoscopic dilation by a single provider from October 2007-October 2012. Outcomes measured included long-term clinical efficacy, interval between sessions, number of dilations, and proportion of radiation strictures that were recurrent or refractory. Risk factors for refractory strictures were assessed. 63 patients underwent 303 dilations. All presented with a stricture >30 days after last radiation session. Clinical success to target diameter was achieved in 52 patients (83%). A mean of 3.3 (±2.6) dilations over a median period of 4 weeks was needed to achieve initial patency. Recurrence occurred in 17 (33%) at a median of 22 weeks. Twenty-seven strictures (43%) were refractory to dilation therapy. Fluoroscopy during dilation (OR 22.88; 95% CI 3.19-164.07), severe esophageal stenosis (lumen <9 mm) (OR 10.51; 95% CI 1.94-56.88), and proximal location with prior malignancy extrinsic to the lumen (OR 6.96; 95% CI 1.33-36.29) were independent predictors of refractory strictures in multivariate analysis. (1) Radiation-induced strictures have a delayed onset (>30 days) from time of radiation injury. (2) Endoscopic dilation can achieve medium-term luminal remediation but the strictures have a high long-term recurrence rate of up to 33%. (3) Remediation of radiation strictures following laryngectomy can be achieved but require frequent dilations. (4) Clinical and procedural predictors may identify patients at high risk of refractory strictures. (5) The optimal strategy in highly selected refractory patients is not clear.
Agarwalla, Anant; Small, Aaron J.; Mendelson, Aaron H.; Scott, Frank I.; Kochman, Michael L.
2014-01-01
Background Radiation therapy for head, neck, and esophageal cancer can result in esophageal strictures that may be difficult to manage. Radiation-induced esophageal strictures often require repeat dilation to obtain relief of dysphagia. This study aimed to determine the long-term clinical success and rates of recurrent and refractory stenosis in patients with radiation-induced strictures undergoing dilation. Methods Retrospective cohort study of patients with radiation-induced strictures who underwent endoscopic dilation by a single provider from October 2007– October 2012. Outcomes measured included long-term clinical efficacy, interval between sessions, number of dilations, and proportion of radiation strictures that were recurrent or refractory. Risk factors for refractory strictures were assessed. Results 63 patients underwent 303 dilations. All presented with a stricture > 30 days after last radiation session. Clinical success to target diameter was achieved in 52 patients (83%). A mean of 3.3 (+/− 2.6) dilations over a median period of 4 weeks was needed to achieve initial patency. Recurrence occurred in 17 (33%) at a median of 22 weeks. Twenty-seven strictures (43%) were refractory to dilation therapy. Fluoroscopy during dilation (OR, 22.88; 95% CI, 3.19 – 164.07), severe esophageal stenosis (lumen <9 mm) (OR, 10.51; 95% CI, 1.94 – 56.88), and proximal location with prior malignancy extrinsic to the lumen (OR, 6.96; 95% CI, 1.33 – 36.29) were independent predictors of refractory strictures in multivariate analysis. Conclusions 1. Radiation-induced strictures have a delayed onset (>30 days) from time of radiation injury. 2. Endoscopic dilation can achieve medium-term luminal remediation but the strictures have a high long-term recurrence rate of up to 33%. 3. Remediation of radiation strictures following laryngectomy can be achieved but require frequent dilations. 4. Clinical and procedural predictors may identify patients at high risk of refractory strictures. 5. The optimal strategy in highly selected refractory patients is not clear. PMID:25277484
What to Know about External Beam Radiation Therapy
... Radiation Therapy: What To Know About External Beam Radiation Therapy Before treatment starts: You will meet with a doctor or ... and show the therapist where to aim the radiation. When you go for treatment: ■ Don’t have powder, deodorant, Band-Aids ® , or ...
Dispositional optimism, self-framing and medical decision-making.
Zhao, Xu; Huang, Chunlei; Li, Xuesong; Zhao, Xin; Peng, Jiaxi
2015-03-01
Self-framing is an important but underinvestigated area in risk communication and behavioural decision-making, especially in medical settings. The present study aimed to investigate the relationship among dispositional optimism, self-frame and decision-making. Participants (N = 500) responded to the Life Orientation Test-Revised and self-framing test of medical decision-making problem. The participants whose scores were higher than the middle value were regarded as highly optimistic individuals. The rest were regarded as low optimistic individuals. The results showed that compared to the high dispositional optimism group, participants from the low dispositional optimism group showed a greater tendency to use negative vocabulary to construct their self-frame, and tended to choose the radiation therapy with high treatment survival rate, but low 5-year survival rate. Based on the current findings, it can be concluded that self-framing effect still exists in medical situation and individual differences in dispositional optimism can influence the processing of information in a framed decision task, as well as risky decision-making. © 2014 International Union of Psychological Science.
Physical characterization and optimal magnification of a portal imaging system
NASA Astrophysics Data System (ADS)
Bissonnette, Jean-Pierre; Jaffray, David A.; Fenster, Aaron; Munro, Peter
1992-06-01
One problem in radiation therapy is ensuring accurate positioning of the patient so that the prescribed dose is delivered to the diseased regions while healthy tissues are spared. Positioning is usually assessed by exposing film to the high-energy treatment beam. Unfortunately, these films exhibit poor image quality (primarily due to low subject contrast) and the development delays make film impractical to check patient positioning routinely. Therefore, we have been developing a digital video-based imaging system to replace film. The system consists of a copper plate/fluorescent screen detector, a 45 degree(s) mirror, and a TV camera equipped with a large aperture lens. We have determined the signal and noise transfer properties of the imaging system by measuring its MTF(f) and NPS(f) and used these valued to estimate the optimal magnification for the imaging system. We have found that the optimal magnification is 2.3 - 2.5 when optimizing signal transfer (spatial resolution) alone; however, the optimal magnification is only 1.5 - 2.0 if SNR transfer is considered.
Hodge, James W.; Guha, Chandan; Neefjes, Jacques; Gulley, James L.
2012-01-01
The combination of radiation therapy and immunotherapy holds particular promise as a strategy for cancer therapeutics. There is evidence that immunotherapy is most beneficial alone when employed early in the disease process or in combination with standard therapies (e.g., radiation) later in the disease process. Indeed, radiation may act synergistically with immunotherapy to enhance immune responses, inhibit immunosuppression, and/or alter the phenotype of tumor cells, thus rendering them more susceptible to immune-mediated killing. Furthermore, as monotherapies, both immunotherapy and radiation may be insufficient to eliminate tumor masses. However, following immunization with a cancer vaccine, the destruction of even a small percentage of tumor cells by radiation could result in cross-priming and presentation of tumor antigens to the immune system, thereby potentiating antitumor responses. Learning how to exploit radiation-induced changes to tumor-cell antigens, and how to induce effective immune responses to these cumulatively immunogenic stimuli, is an exciting frontier in cancer therapy research. This review examines a) mechanisms by which many forms of radiation therapy can induce or augment antitumor immune responses and b) preclinical systems that demonstrate that immunotherapy can be effectively combined with radiation therapy. Finally, we review current clinical trials where standard-of-care radiation therapy is being combined with immunotherapy. PMID:18777956
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapet, Olivier, E-mail: olivier.chapet@chu-lyon.fr; Udrescu, Corina; Department of Medical Physics, Centre Hospitalier Lyon Sud, Pierre Benite
2014-02-01
Purpose: This study assessed the contribution of ahyaluronic acid (HA) injection between the rectum and the prostate to reducing the dose to the rectal wall in stereotactic body radiation therapy (SBRT). Methods and Materials: As part of a phase 2 study of hypofractionated radiation therapy (62 Gy in 20 fractions), the patients received a transperineal injection of 10 cc HA between the rectum and the prostate. A dosimetric computed tomographic (CT) scan was systematically performed before (CT1) and after (CT2) the injection. Two 9-beam intensity modulated radiation therapy-SBRT plans were optimized for the first 10 patients on both CTs accordingmore » to 2 dosage levels: 5 × 6.5 Gy (PlanA) and 5 × 8.5 Gy (PlanB). Rectal wall parameters were compared with a dose–volume histogram, and the prostate–rectum separation was measured at 7 levels of the prostate on the center line of the organ. Results: For both plans, the average volume of the rectal wall receiving the 90% isodose line (V90%) was reduced up to 90% after injection. There was no significant difference (P=.32) between doses received by the rectal wall on CT1 and CT2 at the base of the prostate. This variation became significant from the median plane to the apex of the prostate (P=.002). No significant differences were found between PlanA without HA and PlanB with HA for each level of the prostate (P=.77, at the isocenter of the prostate). Conclusions: HA injection significantly reduced the dose to the rectal wall and allowed a dose escalation from 6.5 Gy to 8.5 Gy without increasing the dose to the rectum. A phase 2 study is under way in our department to assess the rate of acute and late rectal toxicities when SBRT (5 × 8.5 Gy) is combined with an injection of HA.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilbert, Alexandra, E-mail: a.gilbert@leeds.ac.uk; Ziegler, Lucy; Martland, Maisie
The use of multimodal treatments for rectal cancer has improved cancer-related outcomes but makes monitoring toxicity challenging. Optimizing future radiation therapy regimens requires collection and publication of detailed toxicity data. This review evaluated the quality of toxicity information provided in randomized controlled trials (RCTs) of radiation therapy in rectal cancer and focused on the difference between clinician-reported and patient-reported toxicity. Medline, EMBASE, and the Cochrane Library were searched (January 1995-July 2013) for RCTs reporting late toxicity in patients treated with regimens including preoperative (chemo)radiation therapy. Data on toxicity measures and information on toxicity reported were extracted using Quantitative Analyses ofmore » Normal Tissue Effects in the Clinic recommendations. International Society for Quality of Life Research standards on patient-reported outcomes (PROs) were used to evaluate the quality of patient-reported toxicity. Twenty-one RCT publications met inclusion criteria out of 4144 articles screened. All PRO studies reported higher rates of toxicity symptoms than clinician-reported studies and reported on a wider range and milder symptoms. No clinician-reported study published data on sexual dysfunction. Of the clinician-reported studies, 55% grouped toxicity data related to an organ system together (eg “Bowel”), and 45% presented data only on more-severe (grade ≥3) toxicity. In comparison, all toxicity grades were reported in 79% of PRO publications, and all studies (100%) presented individual symptom toxicity data (eg bowel urgency). However, PRO reporting quality was variable. Only 43% of PRO studies presented baseline data, 28% did not use any psychometrically validated instruments, and only 29% of studies described statistical methods for managing missing data. Analysis of these trials highlights the lack of reporting standards for adverse events and reveals the differences between clinician and patient reporting of toxicity. Recommendations for improving the quality of adverse event data collection are provided, with the aim of improving critical appraisal of outcomes for future studies.« less
The changing role of accelerators in radiation therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, W.F.
Conventional low energy x-rays have been used in radiation therapy since the turn of the century. Van de Graaff and Betatron accelerators changed the complexion of radiation therapy in the mid 1940's by providing significantly deeper penetrating photon beams and also providing therapeutic quality electron beams. The development of Cobalt-60 teletherapy in the mid 1950's suppressed the role of accelerators in radiation therapy for nearly 20 years. However, with the development of reliable isocentric rotating linear accelerators, accelerators are rapidly becoming the most popular conventional therapy devices. Following unfavorable clinical results with fast neutron therapy in the late 1930's andmore » early 1940's, the role of cyclotron produced fast neutrons is presently experiencing a renewal in radiation therapy. Several facilities are also experimenting with heavy charged particle beams for therapy.« less
Svatos, M.; Zankowski, C.; Bednarz, B.
2016-01-01
Purpose: The future of radiation therapy will require advanced inverse planning solutions to support single-arc, multiple-arc, and “4π” delivery modes, which present unique challenges in finding an optimal treatment plan over a vast search space, while still preserving dosimetric accuracy. The successful clinical implementation of such methods would benefit from Monte Carlo (MC) based dose calculation methods, which can offer improvements in dosimetric accuracy when compared to deterministic methods. The standard method for MC based treatment planning optimization leverages the accuracy of the MC dose calculation and efficiency of well-developed optimization methods, by precalculating the fluence to dose relationship within a patient with MC methods and subsequently optimizing the fluence weights. However, the sequential nature of this implementation is computationally time consuming and memory intensive. Methods to reduce the overhead of the MC precalculation have been explored in the past, demonstrating promising reductions of computational time overhead, but with limited impact on the memory overhead due to the sequential nature of the dose calculation and fluence optimization. The authors propose an entirely new form of “concurrent” Monte Carlo treat plan optimization: a platform which optimizes the fluence during the dose calculation, reduces wasted computation time being spent on beamlets that weakly contribute to the final dose distribution, and requires only a low memory footprint to function. In this initial investigation, the authors explore the key theoretical and practical considerations of optimizing fluence in such a manner. Methods: The authors present a novel derivation and implementation of a gradient descent algorithm that allows for optimization during MC particle transport, based on highly stochastic information generated through particle transport of very few histories. A gradient rescaling and renormalization algorithm, and the concept of momentum from stochastic gradient descent were used to address obstacles unique to performing gradient descent fluence optimization during MC particle transport. The authors have applied their method to two simple geometrical phantoms, and one clinical patient geometry to examine the capability of this platform to generate conformal plans as well as assess its computational scaling and efficiency, respectively. Results: The authors obtain a reduction of at least 50% in total histories transported in their investigation compared to a theoretical unweighted beamlet calculation and subsequent fluence optimization method, and observe a roughly fixed optimization time overhead consisting of ∼10% of the total computation time in all cases. Finally, the authors demonstrate a negligible increase in memory overhead of ∼7–8 MB to allow for optimization of a clinical patient geometry surrounded by 36 beams using their platform. Conclusions: This study demonstrates a fluence optimization approach, which could significantly improve the development of next generation radiation therapy solutions while incurring minimal additional computational overhead. PMID:27277051
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reardon, Kelli A.; Read, Paul W.; Morris, Monica M.
2013-07-01
Patients undergoing radiation for left-sided breast cancer have increased rates of coronary artery disease. Free-breathing intensity-modulated radiation therapy (FB-IMRT) and 3-dimensional conformal deep inspiratory–breath hold (3D-DIBH) reduce cardiac irradiation. The purpose of this study is to compare the dose to organs at risk in FB-IMRT vs 3D-DIBH for patients with left-sided breast cancer. Ten patients with left-sided breast cancer had 2 computed tomography scans: free breathing and voluntary DIBH. Optimization of the IMRT plan was performed on the free-breathing scan using 6 noncoplanar tangential beams. The 3D-DIBH plan was optimized on the DIBH scan and used standard tangents. Mean volumesmore » of the heart, the left anterior descending coronary artery (LAD), the total lung, and the right breast receiving 5% to 95% (5% increments) of the prescription dose were calculated. Mean volumes of the heart and the LAD were lower (p<0.05) in 3D-DIBH for volumes receiving 5% to 80% of the prescription dose for the heart and 5% for the LAD. Mean dose to the LAD and heart were lower in 3D-DIBH (p≤0.01). Mean volumes of the total lung were lower in FB-IMRT for dose levels 20% to 75% (p<0.05), but mean dose was not different. Mean volumes of the right breast were not different for any dose; however, mean dose was lower for 3D-DIBH (p = 0.04). 3D-DIBH is an alternative approach to FB-IMRT that provides a clinically equivalent treatment for patients with left-sided breast cancer while sparing organs at risk with increased ease of implementation.« less
Energy optimization in gold nanoparticle enhanced radiation therapy.
Sung, Wonmo; Schuemann, Jan
2018-06-25
Gold nanoparticles (GNPs) have been demonstrated as radiation dose enhancing agents. Kilovoltage external photon beams have been shown to yield the largest enhancement due to the high interaction probability with gold. While orthovoltage irradiations are feasible and promising, they suffer from a reduced tissue penetrating power. This study quantifies the effect of varying photon beam energies on various beam arrangements, body, tumor, and cellular GNP uptake geometries. Cell survival was modeled based on our previously developed GNP-local effect model with radial doses calculated using the TOPAS-nBio Monte Carlo code. Cell survival curves calculated for tumor sites with GNPs were used to calculate the relative biological effectiveness (RBE)-weighted dose. In order to evaluate the plan quality, the ratio of the mean dose between the tumor and normal tissue for 50-250 kVp beams with GNPs was compared to the standard of care using 6 MV photon beams without GNPs for breast and brain tumors. For breast using a single photon beam, kV + GNP was found to yield up to 2.73 times higher mean RBE-weighted dose to the tumor than two tangential megavoltage beams while delivering the same dose to healthy tissue. For irradiation of brain tumors using multiple photon beams, the GNP dose enhancement was found to be effective for energies above 50 keV. A small tumor at shallow depths was found to be the most effective treatment conditions for GNP enhanced radiation therapy. GNP uptake distributions in the cell (with or without nuclear uptake) and the beam arrangement were found to be important factors in determining the optimal photon beam energy.
WE-D-BRD-01: Innovation in Radiation Therapy Delivery: Advanced Digital Linac Features
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xing, L; Wong, J; Li, R
2014-06-15
Last few years has witnessed significant advances in linac technology and therapeutic dose delivery method. Digital linacs equipped with high dose rate FFF beams have been clinically implemented in a number of hospitals. Gated VMAT is becoming increasingly popular in treating tumors affected by respiratory motion. This session is devoted to update the audience with these technical advances and to present our experience in clinically implementing the new linacs and dose delivery methods. Topics to be covered include, technical features of new generation of linacs from different vendors, dosimetric characteristics and clinical need for FFF-beam based IMRT and VMAT, respiration-gatedmore » VMAT, the concept and implementation of station parameter optimized radiation therapy (SPORT), beam level imaging and onboard image guidance tools. Emphasis will be on providing fundamental understanding of the new treatment delivery and image guidance strategies, control systems, and the associated dosimetric characteristics. Commissioning and acceptance experience on these new treatment delivery technologies will be reported. Clinical experience and challenges encountered during the process of implementation of the new treatment techniques and future applications of the systems will also be highlighted. Learning Objectives: Present background knowledge of emerging digital linacs and summarize their key geometric and dosimetric features. SPORT as an emerging radiation therapy modality specifically designed to take advantage of digital linacs. Discuss issues related to the acceptance and commissioning of the digital linacs and FFF beams. Describe clinical utility of the new generation of digital linacs and their future applications.« less
Current advancement in radiation therapy for uterine cervical cancer.
Nakano, Takashi; Ohno, Tatsuya; Ishikawa, Hitoshi; Suzuki, Yoshiyuki; Takahashi, Takeo
2010-01-01
Radiation therapy is one of the effective curative treatments for uterine cervical cancer. However poor clinical results for the advanced stages require further improvement of the treatment. Intensive studies on basic and clinical research have been made to improve local control, primarily important for long term survival in radiation therapy. Regarding current advancement in radiation therapy for uterine cervical cancer, the following three major subjects are pointed out; technological development to improve dose distribution by image guided radiation therapy technology, the concomitant anticancer chemotherapy with combination of radiation therapy, and radiation biological assessment of the radiation resistance of tumors. The biological factors overviewed in this article include hypoxia relating factors of HIF-1alpha, SOD, cell cycle parameters of pMI, proliferation factors of Ki67, EGFR, cerbB2, COX-2, cycle regulation proteins p53, p21, apoptosis regulation proteins Bcl2 and Bax and so on. Especially, the variety of these radiation biological factors is important for the selection of an effective treatment method for each patient to maximize the treatment benefit.
Park, Ji Yeon; Shin, Ji Hoon; Song, Ho-Young; Yi, Seong Yoon; Kim, Jin Hyoung
2012-02-01
The purpose of this study was to evaluate the characteristics of airway complications and survival with special reference to radiation therapy in the care of patients undergoing covered stent placement for malignant esophageal strictures. A total of 208 patients who underwent stent placement with or without palliative radiation therapy for inoperable esophageal cancer were included. The endpoints were frequency, type, and management of airway complications; association between occurrence of airway complications and radiation therapy history; and differences in stent-to-complication interval and survival period after esophageal stenting between patients who underwent radiation therapy before and those who underwent radiation therapy after stent placement. Airway complications occurred in 23 patients (11.1%): 18 (78.3%) had esophagorespiratory fistula, three (13.0%) had airway narrowing, and two (8.7%) had both complications. The frequency of airway complications was significantly greater among patients who underwent RT than those who did not (p = 0.005) but was not significantly different between the radiation before stenting and radiation after stenting groups (p = 0.158). The median stent-to-complication interval and survival period after esophageal stenting were significantly shorter in the radiation before stenting group than in the radiation after stenting group (p = 0.002, p = 0.001). Esophagorespiratory fistula is much more common than airway narrowing as an airway complication. The rate of complications increases significantly in association with radiation therapy among patients with malignant esophageal stricture. Clinicians need to be aware of earlier airway complications and poorer prognosis among patients who undergo radiation therapy before placement of an esophageal stent than in patients who undergo radiation after stent placement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, Mehul K.; Cote, Michele L.; Ali-Fehmi, Rouba
2012-05-01
Purpose: The optimal adjuvant radiation treatment for endometrial carcinoma (EC) remains controversial. Adjuvant vaginal cuff brachytherapy (VB) has emerged as an increasingly common treatment modality. However, the time trends for using VB, external beam radiation therapy (EBRT), or combined therapy (VB+EBRT) have not been well characterized. We therefore examined the utilization trends of VB, EBRT, and VB+EBRT for adjuvant RT in International Federation of Gynecologic Oncology (FIGO) stage I and II EC over time. Methods and Materials: We evaluated treatment patterns for 48,122 patients with EC diagnosed between January 1995 and December 2005, using the National Cancer Institute's Surveillance, Epidemiology,more » and End Results (SEER) public use database. Chi-squared tests were used to assess differences by radiation type (VB, EBRT, and VB+EBRT) and various demographic and clinical variables. Results: Analyses were limited to 9,815 patients (20.4%) with EC who met the inclusion criteria. Among women who received adjuvant RT, the proportion receiving VB increased yearly (12.9% in 1995 compared to 32.8% in 2005 (p < 0.0001). The increasing use of VB was proportional to the decreasing use of EBRT (56.1% in 1995 to 45.8% in 2005; p < 0.0001) and VB+EBRT (31.0% in 1995 to 21.4% in 2005; p < 0.001). Conclusions: This population-based report demonstrates an increasing trend in the use of VB in the adjuvant setting after hysterectomy for treatment of women with FIGO stage I-II EC. VB alone appears to be replacing pelvic EBRT and VB+EBRT therapy in the management of stage I-II EC.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qi, X. Sharon, E-mail: xqi@mednet.ucla.edu; Department of Radiation Oncology, University of Colorado Denver, Aurora, Colorado; Stinauer, Michelle
Purpose: To compare volumetric modulated arc therapy (VMAT) with 3-dimensional conformal radiation therapy (3D-CRT) in the treatment of localized intracranial germinoma. We modeled the effect of the dosimetric differences on intelligence quotient (IQ). Method and Materials: Ten children with intracranial germinomas were used for planning. The prescription doses were 23.4 Gy to the ventricles followed by 21.6 Gy to the tumor located in the pineal region. For each child, a 3D-CRT and full arc VMAT was generated. Coverage of the target was assessed by computing a conformity index and heterogeneity index. We also generated VMAT plans with explicit temporal lobemore » sparing and with smaller ventricular margin expansions. Mean dose to the temporal lobe was used to estimate IQ 5 years after completion of radiation, using a patient age of 10 years. Results: Compared with the 3D-CRT plan, VMAT improved conformality (conformity index 1.10 vs 1.85), with slightly higher heterogeneity (heterogeneity index 1.09 vs 1.06). The averaged mean doses for left and right temporal lobes were 31.3 and 31.7 Gy, respectively, for VMAT plans and 37.7 and 37.6 Gy for 3D-CRT plans. This difference in mean temporal lobe dose resulted in an estimated IQ difference of 3.1 points at 5 years after radiation therapy. When the temporal lobes were explicitly included in the VMAT optimization, the mean temporal lobe dose was reduced 5.6-5.7 Gy, resulting in an estimated IQ difference of an additional 3 points. Reducing the ventricular margin from 1.5 cm to 0.5 cm decreased mean temporal lobe dose 11.4-13.1 Gy, corresponding to an estimated increase in IQ of 7 points. Conclusion: For treatment of children with intracranial pure germinomas, VMAT compared with 3D-CRT provides increased conformality and reduces doses to normal tissue. This may result in improvements in IQ in these children.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arvold, Nils D.; Tanguturi, Shyam K.; Aizer, Ayal A.
Purpose: Older patients with newly diagnosed glioblastoma have poor outcomes, and optimal treatment is controversial. Hypofractionated radiation therapy (HRT) is frequently used but has not been compared to patients receiving standard fractionated radiation therapy (SRT) and temozolomide (TMZ). Methods and Materials: We conducted a retrospective analysis of patients ≥65 years of age who received radiation for the treatment of newly diagnosed glioblastoma from 1994 to 2013. The distribution of clinical covariates across various radiation regimens was analyzed for possible selection bias. Survival was calculated using the Kaplan-Meier method. Comparison of hypofractionated radiation (typically, 40 Gy/15 fractions) versus standard fractionation (typically, 60 Gy/30 fractions)more » in the setting of temozolomide was conducted using Cox regression and propensity score analysis. Results: Patients received SRT + TMZ (n=57), SRT (n=35), HRT + TMZ (n=34), or HRT (n=9). Patients receiving HRT were significantly older (median: 79 vs 69 years of age; P<.001) and had worse baseline performance status (P<.001) than those receiving SRT. On multivariate analysis, older age (adjusted hazard ratio [AHR]: 1.06; 95% confidence interval [CI]: 1.01-1.10, P=.01), lower Karnofsky performance status (AHR: 1.02; 95% CI: 1.01-1.03; P=.01), multifocal disease (AHR: 2.11; 95% CI: 1.23-3.61, P=.007), and radiation alone (vs SRT + TMZ; SRT: AHR: 1.72; 95% CI: 1.06-2.79; P=.03; HRT: AHR: 3.92; 95% CI: 1.44-10.60, P=.007) were associated with decreased overall survival. After propensity score adjustment, patients receiving HRT with TMZ had similar overall survival compared with those receiving SRT with TMZ (AHR: 1.10, 95% CI: 0.50-2.4, P=.82). Conclusions: With no randomized data demonstrating equivalence between HRT and SRT in the setting of TMZ for glioblastoma, significant selection bias exists in the implementation of HRT. Controlling for this bias, we observed similar overall survival for HRT and SRT with concurrent TMZ among elderly patients, suggesting the need for a randomized trial to compare these regimens directly.« less
Potential application of metal nanoparticles for dosimetric systems: Concepts and perspectives
NASA Astrophysics Data System (ADS)
Guidelli, Eder José; Baffa, Oswaldo
2014-11-01
Metallic nanoparticles increase the delivered dose and consequently enhance tissue radio sensitization during radiation therapy of cancer. The Dose Enhancement Factor (DEF) corresponds to the ratio between the dose deposited on a tissue containing nanoparticles, and the dose deposited on a tissue without nanoparticles. In this sense, we have used electron spin resonance spectroscopy (ESR) to investigate how silver and gold nanoparticles affect the dose deposition in alanine dosimeters, which act as a surrogate of soft tissue. Besides optimizing radiation absorption by the dosimeter, the optical properties of these metal nanoparticles could also improve light emission from materials employed as radiation detectors. Therefore, we have also examined how the plasmonic properties of noble metal nanoparticles could enhance radiation detection using optically stimulated luminescence (OSL) dosimetry. This work will show results on how the use of gold and silver nanoparticles are beneficial for the ESR and OSL dosimetric techniques, and will describe the difficulties we have been facing, the challenges to overcome, and the perspectives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Min-Joo; Park, So-Hyun; Research Institute of Biomedical Engineering, The Catholic University of Korea, Seoul
2013-10-01
The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dosemore » homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue.« less
1997-07-01
Review Board of the DFCI is provided in Appendix A . The investigator will keep the following information on each patient: 1. Past medical ...treatments, you will receive radiation therapy to your breast. Your radiation oncologist will decide what radiation dose you receive . On the basis of... Activities 6/87 Controversies in radiation therapy in
Postoperative radiation in esophageal squamous cell carcinoma and target volume delineation
Zhu, Yingming; Li, Minghuan; Kong, Li; Yu, Jinming
2016-01-01
Esophageal cancer is the sixth leading cause of cancer death worldwide, and patients who are treated with surgery alone, without neoadjuvant therapies, experience frequent relapses. Whether postoperative therapies could reduce the recurrence or improve overall survival is still controversial for these patients. The purpose of our review is to figure out the value of postoperative adjuvant therapy and address the disputes about target volume delineation according to published data. Based on the evidence of increased morbidity and disadvantages on patient survival caused by postoperative chemotherapy or radiotherapy (RT) alone provided by studies in the early 1990s, the use of postoperative adjuvant therapies in cases of esophageal squamous cell carcinoma has diminished substantially and has been replaced gradually by neoadjuvant chemoradiation. With advances in surgery and RT, accumulating evidence has recently rekindled interest in the delivery of postoperative RT or chemoradiotherapy in patients with stage T3/T4 or N1 (lymph node positive) carcinomas after radical surgery. However, due to complications with the standard radiation field, a nonconforming modified field has been adopted in most studies. Therefore, we analyze different field applications and provide suggestions on the optimization of the radiation field based on the major sites of relapse and the surgical non-clearance area. For upper and middle thoracic esophageal carcinomas, the bilateral supraclavicular and superior mediastinal areas remain common sites of recurrence and should be encompassed within the clinical target volume. In contrast, a consensus has yet to be reached regarding lower thoracic esophageal carcinomas; the “standard” clinical target volume is still recommended. Further studies of larger sample sizes should focus on different recurrence patterns, categorized by tumor locations, refined classifications, and differing molecular biology, to provide more information on the delineation of target volumes. PMID:27471393
ASPS clinical practice guideline summary on breast reconstruction with expanders and implants.
Alderman, Amy; Gutowski, Karol; Ahuja, Amy; Gray, Diedra
2014-10-01
After reading this article, participants should be able to: 1. Understand the evidence regarding the timing of expander/implant breast reconstruction in the setting of radiation therapy. 2. Discuss the implications of a patient's risk factors for possible outcomes and complications of expander/implant breast reconstruction. 3. Implement proper prophylactic antibiotic protocols. 4. Use the guidelines to improve their own clinical outcomes and reduce complications. In March of 2013, the Executive Committee of the American Society of Plastic Surgeons approved an evidence-based guideline on breast reconstruction with expanders and implants, as developed by a guideline-specific work group commissioned by the society's Health Policy Committee. The guideline addresses ten clinical questions: patient education, immediate versus delayed reconstruction, risk factors, radiation therapy, chemotherapy, hormonal therapy, antibiotic prophylaxis, acellular dermal matrix, monitoring for cancer recurrence, and oncologic outcomes associated with implant-based reconstruction. The evidence indicates that patients undergoing mastectomy should be offered a preoperative referral to a plastic surgeon. Evidence varies regarding the association between postoperative complications and timing of postmastectomy expander/implant breast reconstruction. Evidence is limited regarding the optimal timing of expand/implant reconstruction in the setting of radiation therapy but suggests that irradiation to the expander or implant is associated with an increased risk of postoperative complications. Evidence also varies regarding the association between acellular dermal matrix and surgical complications in the setting of postmastectomy expander/implant reconstruction. Data support the use of an appropriate preoperative antibiotic, but antibiotics should be discontinued within 24 hours of the procedure, unless a surgical drain is present. Furthermore, postmastectomy expander/implant breast reconstruction does not adversely affect oncologic outcomes.
Internal Radiation Therapy for Cancer
When getting internal radiation therapy, a source of radiation is put inside your body, in either liquid or solid form. It can be used treat different kinds of cancer, including thyroid, head and neck, breast, cervix, prostate, and eye. Learn more about how what to expect when getting internal radiation therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jensen, Alexandra D., E-mail: Alexandra.Jensen@med.uni-heidelberg.de; Nill, Simeon; Huber, Peter E.
Purpose: To present an approach to fast, interfractional adaptive RT in intensity-modulated radiation therapy (IMRT) of head and neck tumors in clinical routine. Ensuring adequate patient position throughout treatment proves challenging in high-precision RT despite elaborate immobilization. Because of weight loss, treatment plans must be adapted to account for requiring supportive therapy incl. feeding tube or parenteral nutrition without treatment breaks. Methods and Materials: In-room CT position checks are used to create adapted IMRT treatment plans by stereotactic correlation to the initial setup, and volumes are adapted to the new geometry. New IMRT treatment plans are prospectively created on themore » basis of position control scans using the initial optimization parameters in KonRad without requiring complete reoptimization and thus facilitating quick replanning in daily routine. Patients treated for squamous cell head and neck cancer (SCCHN) in 2006-2007 were evaluated as to necessity/number of replannings, weight loss, dose, and plan parameters. Results: Seventy-two patients with SCCHN received IMRT to the primary site and lymph nodes (median dose 70.4 Gy). All patients received concomitant chemotherapy requiring supportive therapy by feeding tube or parenteral nutrition. Median weight loss was 7.8 kg, median volume loss was approximately 7%. Fifteen of 72 patients required adaptation of their treatment plans at least once. Target coverage was improved by up to 10.7% (median dose). The increase of dose to spared parotid without replanning was 11.7%. Replanning including outlining and optimization was feasible within 2 hours for each patient, and treatment could be continued without any interruptions. Conclusion: To preserve high-quality dose application, treatment plans must be adapted to anatomical changes. Replanning based on position control scans therefore presents a practical approach in clinical routine. In the absence of clinically usable online correction methods, this approach allows significant improvement of target volume coverage and continuous parotid sparing without treatment delays.« less
Jensen, Alexandra D; Nill, Simeon; Huber, Peter E; Bendl, Rolf; Debus, Jürgen; Münter, Marc W
2012-02-01
To present an approach to fast, interfractional adaptive RT in intensity-modulated radiation therapy (IMRT) of head and neck tumors in clinical routine. Ensuring adequate patient position throughout treatment proves challenging in high-precision RT despite elaborate immobilization. Because of weight loss, treatment plans must be adapted to account for requiring supportive therapy incl. feeding tube or parenteral nutrition without treatment breaks. In-room CT position checks are used to create adapted IMRT treatment plans by stereotactic correlation to the initial setup, and volumes are adapted to the new geometry. New IMRT treatment plans are prospectively created on the basis of position control scans using the initial optimization parameters in KonRad without requiring complete reoptimization and thus facilitating quick replanning in daily routine. Patients treated for squamous cell head and neck cancer (SCCHN) in 2006-2007 were evaluated as to necessity/number of replannings, weight loss, dose, and plan parameters. Seventy-two patients with SCCHN received IMRT to the primary site and lymph nodes (median dose 70.4 Gy). All patients received concomitant chemotherapy requiring supportive therapy by feeding tube or parenteral nutrition. Median weight loss was 7.8 kg, median volume loss was approximately 7%. Fifteen of 72 patients required adaptation of their treatment plans at least once. Target coverage was improved by up to 10.7% (median dose). The increase of dose to spared parotid without replanning was 11.7%. Replanning including outlining and optimization was feasible within 2 hours for each patient, and treatment could be continued without any interruptions. To preserve high-quality dose application, treatment plans must be adapted to anatomical changes. Replanning based on position control scans therefore presents a practical approach in clinical routine. In the absence of clinically usable online correction methods, this approach allows significant improvement of target volume coverage and continuous parotid sparing without treatment delays. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Y. M., E-mail: ymingy@gmail.com; Bednarz, B.; Svatos, M.
Purpose: The future of radiation therapy will require advanced inverse planning solutions to support single-arc, multiple-arc, and “4π” delivery modes, which present unique challenges in finding an optimal treatment plan over a vast search space, while still preserving dosimetric accuracy. The successful clinical implementation of such methods would benefit from Monte Carlo (MC) based dose calculation methods, which can offer improvements in dosimetric accuracy when compared to deterministic methods. The standard method for MC based treatment planning optimization leverages the accuracy of the MC dose calculation and efficiency of well-developed optimization methods, by precalculating the fluence to dose relationship withinmore » a patient with MC methods and subsequently optimizing the fluence weights. However, the sequential nature of this implementation is computationally time consuming and memory intensive. Methods to reduce the overhead of the MC precalculation have been explored in the past, demonstrating promising reductions of computational time overhead, but with limited impact on the memory overhead due to the sequential nature of the dose calculation and fluence optimization. The authors propose an entirely new form of “concurrent” Monte Carlo treat plan optimization: a platform which optimizes the fluence during the dose calculation, reduces wasted computation time being spent on beamlets that weakly contribute to the final dose distribution, and requires only a low memory footprint to function. In this initial investigation, the authors explore the key theoretical and practical considerations of optimizing fluence in such a manner. Methods: The authors present a novel derivation and implementation of a gradient descent algorithm that allows for optimization during MC particle transport, based on highly stochastic information generated through particle transport of very few histories. A gradient rescaling and renormalization algorithm, and the concept of momentum from stochastic gradient descent were used to address obstacles unique to performing gradient descent fluence optimization during MC particle transport. The authors have applied their method to two simple geometrical phantoms, and one clinical patient geometry to examine the capability of this platform to generate conformal plans as well as assess its computational scaling and efficiency, respectively. Results: The authors obtain a reduction of at least 50% in total histories transported in their investigation compared to a theoretical unweighted beamlet calculation and subsequent fluence optimization method, and observe a roughly fixed optimization time overhead consisting of ∼10% of the total computation time in all cases. Finally, the authors demonstrate a negligible increase in memory overhead of ∼7–8 MB to allow for optimization of a clinical patient geometry surrounded by 36 beams using their platform. Conclusions: This study demonstrates a fluence optimization approach, which could significantly improve the development of next generation radiation therapy solutions while incurring minimal additional computational overhead.« less
Very High-Risk Localized Prostate Cancer: Outcomes Following Definitive Radiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Narang, Amol K.; Gergis, Carol; Robertson, Scott P.
Purpose: Existing definitions of high-risk prostate cancer consist of men who experience significant heterogeneity in outcomes. As such, criteria that identify a subpopulation of National Comprehensive Cancer Network (NCCN) high-risk prostate cancer patients who are at very high risk (VHR) for poor survival outcomes following prostatectomy were recently developed at our institution and include the presence of any of the following disease characteristics: multiple NCCN high-risk factors, primary Gleason pattern 5 disease and/or ≥5 biopsy cores with Gleason sums of 8 to 10. Whether these criteria also apply to men undergoing definitive radiation is unclear, as is the optimal treatment regimenmore » in these patients. Methods and Materials: All men consecutively treated with definitive radiation by a single provider from 1993 to 2006 and who fulfilled criteria for NCCN high-risk disease were identified (n=288), including 99 patients (34%) with VHR disease. Multivariate-adjusted competing risk regression models were constructed to assess associations between the VHR definition and biochemical failure (BF), distant metastasis (DM), and prostate cancer–specific mortality (PCSM). Multivariate-adjusted Cox regression analysis assessed the association of the VHR definition with overall mortality (OM). Cumulative incidences of failure endpoints were compared between VHR men and other NCCN high-risk men. Results: Men with VHR disease compared to other NCCN high-risk men experienced a higher 10-year incidence of BF (54.0% vs 35.4%, respectively, P<.001), DM (34.9% vs 13.4%, respectively, P<.001), PCSM (18.5% vs 5.9%, respectively, P<.001), and OM (36.4% vs 27.0%, respectively, P=.04). VHR men with a detectable prostate-specific antigen (PSA) concentration at the end of radiation (EOR) remained at high risk of 10-year PCSM compared to VHR men with an undetectable EOR PSA (31.0% vs 13.7%, respectively, P=.05). Conclusions: NCCN high-risk prostate cancer patients who meet VHR criteria experience distinctly worse outcomes following definitive radiation and long-term androgen deprivation therapy, particularly if an EOR PSA is detectable. Optimal use of local therapies for VHR patients should be explored further, as should novel agents.« less
21 CFR 892.5770 - Powered radiation therapy patient support assembly.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Powered radiation therapy patient support assembly. 892.5770 Section 892.5770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... therapy patient support assembly. (a) Identification. A powered radiation therapy patient support assembly...
21 CFR 892.5770 - Powered radiation therapy patient support assembly.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Powered radiation therapy patient support assembly. 892.5770 Section 892.5770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... therapy patient support assembly. (a) Identification. A powered radiation therapy patient support assembly...
21 CFR 892.5770 - Powered radiation therapy patient support assembly.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Powered radiation therapy patient support assembly. 892.5770 Section 892.5770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... therapy patient support assembly. (a) Identification. A powered radiation therapy patient support assembly...
21 CFR 892.5770 - Powered radiation therapy patient support assembly.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Powered radiation therapy patient support assembly. 892.5770 Section 892.5770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... therapy patient support assembly. (a) Identification. A powered radiation therapy patient support assembly...
Radiation Therapy: Professions in Radiation Therapy
... and typically one to two years of clinical physics training. They are certified by the American Board of Radiology or the American Board of Medical Physics . Radiation Therapist Radiation therapists work with radiation oncologists. ...
Ritter, E F; Lee, C G; Tyler, D; Ferraro, F; Whiddon, C; Rudner, A M; Scully, S
1997-02-01
As a part of multimodality therapy, many patients with tumors of the trunk receive radiation therapy. The major morbidity of this therapy is often secondary to incidental radiation damage to tissues adjacent to treatment areas. We detail our use of saline breast implants placed in polyglycolic acid mesh sheets to displace visceral and solid organs away from the radiation field. Analysis of CT scans and dose volume histograms reveal that this technique successfully displaces uninvolved organs away from the radiation fields, thereby minimizing the radiation dose to such organs and tissues. We believe this is a safe and efficacious method to prevent radiation damage to visceral and solid organs adjacent to trunk tumor sites.
External radiation exposure, excretion, and effective half-life in 177Lu-PSMA-targeted therapies.
Kurth, J; Krause, B J; Schwarzenböck, S M; Stegger, L; Schäfers, M; Rahbar, K
2018-04-12
Prostate-specific membrane antigen (PSMA)-targeted therapy with 177 Lu-PSMA-617 is a therapeutic option for patients with metastatic castration-resistant prostate cancer (mCRPC). To optimize the therapy procedure, it is necessary to determine relevant parameters to define radiation protection and safety necessities. Therefore, this study aimed at estimating the ambient radiation exposure received by the patient. Moreover, the excreted activity was quantified. In total, 50 patients with mCRPC and treated with 177 Lu-PSMA-617 (mean administered activity 6.3 ± 0.5 GBq) were retrospectively included in a bi-centric study. Whole-body dose rates were measured at a distance of 2 m at various time points after application of 177 Lu-PSMA-617, and effective half-lives for different time points were calculated and compared. Radiation exposure to the public was approximated using the dose integral. For the estimation of the excreted activity, whole body measurements of 25 patients were performed at 7 time points. Unbound 177 Lu-PSMA-617 was rapidly cleared from the body. After 4 h, approximately 50% and, after 12 h, approximately 70% of the administered activity were excreted, primarily via urine. The mean dose rates were the following: 3.6 ± 0.7 μSv/h at 2 h p. i., 1.6 ± 0.6 μSv/h at 24 h, 1.1 ± 0.5 μSv/h at 48 h, and 0.7 ± 0.4 μSv/h at 72 h. The mean effective half-life of the cohort was 40.5 ± 9.6 h (min 21.7 h; max 85.7 h). The maximum dose to individual members of the public per treatment cycle was ~ 250 ± 55 μSv when the patient was discharged from the clinic after 48 h and ~ 190 ± 36 μSv when the patient was discharged after 72 h. In terms of the radiation exposure to the public, 177 Lu-PSMA is a safe option of radionuclide therapy. As usually four (sometimes more) cycles of the therapy are performed, it must be conducted in a way that ensures that applicable legal requirements can be followed. In other words, the radiation exposure to the public and the concentration of activity in wastewater must be sub-marginal. Therefore, in certain countries, hospitalization of these patients is mandatory.
Mbeutcha, Aurélie; Chauveinc, Laurent; Bondiau, Pierre-Yves; Chand, Marie-Eve; Durand, Matthieu; Chevallier, Daniel; Amiel, Jean; Kee, Daniel Lam Cham; Hannoun-Lévi, Jean-Michel
2017-03-09
Optimal management of locally recurrent prostate cancer after definitive radiation therapy is still challenging. With the development of highly accurate radiotherapy devices, prostate salvage re-irradiation might generate lower toxicity rates than classical salvage therapies. We retrospectively evaluated the toxicity and the feasibility of a prostate re-irradiation after definitive radiation therapy failure. Two modalities were investigated: high-dose-rate brachytherapy (HDRB) on whole prostate gland and focal stereotactic radiotherapy (SBRT) using CyberKnife® linac. Between 2011 and 2015, 28 patients with imaged and/or biopsy-proven intra-prostatic recurrence of cancer after definitive radiation therapy underwent a salvage re-irradiation using HDRB (n = 10) or focal SBRT (n = 18). The schedule of re-irradiation was 35 Gy in 5 fractions. Biological response (defined as post-salvage radiation PSA variation) and biochemical no-evidence of disease (bNED) were evaluated in the whole cohort. For patients who had a positive biological response after salvage radiation, biochemical recurrence (BCR) and survival after salvage radiotherapy were evaluated. Post-salvage toxicities were assessed according to the Common Terminology Criteria for Adverse Events (CTCAE) v4.03 and were compared to baseline status. Within a median follow-up of 22.5 months (IQR = 8-42), 9 (90%) patients experienced a positive biological response after salvage HDRB and 5 (50%) remained bNED at the end of the follow-up. Among patients who initially responded to salvage HDRB, the BCR rate was 44.4% after a median interval of 19.5 months (IQR = 11.5-26). Only one patient experienced a transient grade 3 urinary complication. In the SBRT group, the median follow-up was 14.5 months (IQR = 7-23) and 10 (55.6%) out of the 18 patients remained bNED. Among the 15 patients who initially responded to salvage SBRT, 5 (33.3%) experienced a BCR. One patient experienced a transient grade 4 urinary complication. At the end of the follow-up, all evaluated patients had a urinary status grade variation ≤ +1 grade. No grade 3-4 digestive toxicity was observed. Salvage prostate re-irradiation for locally recurrent cancer is feasible and generate low toxicities rates when using with HDRB or focal SBRT. However, further investigations are necessary to confirm these findings and to determine predictive features for patients who might benefit from such an approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xinfeng; Prior, Phil; Chen, Guang-Pei
Purpose: The integration of MRI with a linear accelerator (MR-linac) offers great potential for high-precision delivery of radiation therapy (RT). However, the electron deflection resulting from the presence of a transverse magnetic field (TMF) can affect the dose distribution, particularly the electron return effect (ERE) at tissue interfaces. The purpose of the study is to investigate the dose effects of ERE at air-tissue and lung-tissue interfaces during intensity-modulated radiation therapy (IMRT) planning. Methods: IMRT and volumetric modulated arc therapy (VMAT) plans for representative pancreas, lung, breast, and head and neck (HN) cases were generated following commonly used clinical dose volumemore » (DV) criteria. In each case, three types of plans were generated: (1) the original plan generated without a TMF; (2) the reconstructed plan generated by recalculating the original plan with the presence of a TMF of 1.5 T (no optimization); and (3) the optimized plan generated by a full optimization with TMF = 1.5 T. These plans were compared using a variety of DV parameters, including V{sub 100%}, D{sub 95%}, DHI [dose heterogeneity index: (D{sub 20%}–D{sub 80%})/D{sub prescription}], D{sub max}, and D{sub 1cc} in OARs (organs at risk) and tissue interface. All the optimizations and calculations in this work were performed on static data. Results: The dose recalculation under TMF showed the presence of the 1.5 T TMF can slightly reduce V{sub 100%} and D{sub 95%} for PTV, with the differences being less than 4% for all but one lung case studied. The TMF results in considerable increases in D{sub max} and D{sub 1cc} on the skin in all cases, mostly between 10% and 35%. The changes in D{sub max} and D{sub 1cc} on air cavity walls are dependent upon site, geometry, and size, with changes ranging up to 15%. The VMAT plans lead to much smaller dose effects from ERE compared to fixed-beam IMRT in pancreas case. When the TMF is considered in the plan optimization, the dose effects of the TMF at tissue interfaces (e.g., air-cavity wall, lung-tissue interfaces, skin) are significantly reduced in most cases. Conclusions: The doses on tissue interfaces can be significantly changed by the presence of a TMF during MR-guided RT when the magnetic field is not included in plan optimization. These changes can be substantially reduced or even eliminated during VMAT/IMRT optimization that specifically considers the TMF, without deteriorating overall plan quality.« less
Kapatkin, Amy S; Nordquist, Barbro; Garcia, Tanya C; Griffin, Maureen A; Theon, Alain; Kim, Sun; Hayashi, Kei
2016-07-19
To determine if a single low dose of radiation therapy in dogs with osteoarthritis of the elbow joint was associated with a detectable improvement in their lameness and pain as documented by force platform gait analysis. In this cohort longitudinal observational study, five Labrador Retrievers with lameness due to elbow osteoarthritis that was unresponsive to medical treatment were removed from all non-steroidal anti-inflammatory and analgesic medications. A single treatment of radiation therapy delivering 10 Gray was performed on the affected elbow joint(s). Force platform gait analysis was used to assess the ground reaction forces of a limb affected with elbow osteoarthritis both before and after radiation therapy. Significant differences occurred in the weight-bearing on an affected limb with elbow osteoarthritis after radiation therapy at weeks six and 14. Change due to treatment was particularly apparent in dogs with unilateral elbow osteoarthritis. Administering a single low dose of radiation therapy may have a short-term benefit in dogs with elbow osteoarthritis, which is similar to the evidence supporting the use of radiation therapy in horses with orthopaedic disease.
Reducing rectal injury in men receiving prostate cancer radiation therapy: current perspectives
Serrano, Nicholas A; Kalman, Noah S; Anscher, Mitchell S
2017-01-01
Dose escalation is now the standard of care for the treatment of prostate cancer with radiation therapy. However, the rectum tends to be the dose-limiting structure when treating prostate cancer, given its close proximity. Early and late toxicities can occur when the rectum receives large doses of radiation therapy. New technologies allow for prevention of these toxicities. In this review, we examine the evidence that supports various dose constraints employed to prevent these rectal injuries from occurring. We also examine the use of intensity-modulated radiation therapy and how this compares to older radiation therapy techniques that allow for further sparing of the rectum during a radiation therapy course. We then review the literature on endorectal balloons and the effects of their daily use throughout a radiation therapy course. Tissue spacers are now being investigated in greater detail; these devices are injected into the rectoprostatic fascia to physically increase the distance between the prostate and the anterior rectal wall. Last, we review the use of systemic drugs, specifically statin medications and antihypertensives, as well as their impact on rectal toxicity. PMID:28814898
TH-F-202-03: Advances in MRI for Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, J.
MRI has excellent soft tissue contrast and can provide both anatomical and physiological information. It is becoming increasingly important in radiation therapy for treatment planning, image-guided radiation therapy, and treatment assessment. It is critically important at this time point to educate and update our medical physicists about MRI to prepare for the upcoming surge of MRI applications in radiation therapy. This session will review important basics of MR physics, pulse sequence designs, and current radiotherapy application, as well as showcase exciting new developments in MRI that can be potentially useful in radiation therapy. Learning Objectives: To learn basics of MRmore » physics and understand the differences between various pulse sequences To review current applications of MRI in radiation therapy.To discuss recent MRI advances for future MRI guided radiation therapy Partly supported by NIH (1R21CA165384).; W. Miller, Research supported in part by Siemens Healthcare; G. Li, My clinical research is in part supported by NIH U54CA137788. I have a collaborative research project with Philips Healthcare.; J. Cai, jing cai.« less
TH-F-202-00: MRI for Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
MRI has excellent soft tissue contrast and can provide both anatomical and physiological information. It is becoming increasingly important in radiation therapy for treatment planning, image-guided radiation therapy, and treatment assessment. It is critically important at this time point to educate and update our medical physicists about MRI to prepare for the upcoming surge of MRI applications in radiation therapy. This session will review important basics of MR physics, pulse sequence designs, and current radiotherapy application, as well as showcase exciting new developments in MRI that can be potentially useful in radiation therapy. Learning Objectives: To learn basics of MRmore » physics and understand the differences between various pulse sequences To review current applications of MRI in radiation therapy.To discuss recent MRI advances for future MRI guided radiation therapy Partly supported by NIH (1R21CA165384).; W. Miller, Research supported in part by Siemens Healthcare; G. Li, My clinical research is in part supported by NIH U54CA137788. I have a collaborative research project with Philips Healthcare.; J. Cai, jing cai.« less
Positioning Vascularized Composite Allotransplantation in the Spectrum of Transplantation
2017-10-01
have now shown that the efficacy of both protocols is dependent upon a radiation-sensitive donor bone marrow (BM) cell type that is of T or B cell... dependent VCA survival. IL-2C Therapy Increases the Number but Not Function of Foxp3 CD4+ Treg Cells To test the effects of JES6-1 mAb-based IL-2C...which Treg cell- dependent immunoregulation has considerable potential. These IL-2C studies are now “in press” (4). TASK 5: OPTIMAL COMBINATION
Optimized Hyperthermia Treatment of Prostate Cancer Using a Novel Intracavitary Ultrasound Array
2006-01-01
Overgaard J, Gonzalez GD, Hulshof MC, Arcangeli G, Dahl O, Mella O, et al. 1995. Randomised trial of hyperthermia as adjuvant to radiotherapy for...Gonzalez, G. D., Hulshof , M. C., Arcangeli, G., Dahl, O., Mella, O., and Bentzen, S. M., "Hyperthermia as an adjuvant to radiation therapy of recurrent or...25 pp. 79-85, 1993. 9. Overgaard, J., Gonzalez, G. D., Hulshof , M. C., Arcangeli, G., Dahl, O., Mella, O., and Bentzen, S. M.: Hyperthermia as an
Investigating multi-objective fluence and beam orientation IMRT optimization
NASA Astrophysics Data System (ADS)
Potrebko, Peter S.; Fiege, Jason; Biagioli, Matthew; Poleszczuk, Jan
2017-07-01
Radiation Oncology treatment planning requires compromises to be made between clinical objectives that are invariably in conflict. It would be beneficial to have a ‘bird’s-eye-view’ perspective of the full spectrum of treatment plans that represent the possible trade-offs between delivering the intended dose to the planning target volume (PTV) while optimally sparing the organs-at-risk (OARs). In this work, the authors demonstrate Pareto-aware radiotherapy evolutionary treatment optimization (PARETO), a multi-objective tool featuring such bird’s-eye-view functionality, which optimizes fluence patterns and beam angles for intensity-modulated radiation therapy (IMRT) treatment planning. The problem of IMRT treatment plan optimization is managed as a combined monolithic problem, where all beam fluence and angle parameters are treated equally during the optimization. To achieve this, PARETO is built around a powerful multi-objective evolutionary algorithm, called Ferret, which simultaneously optimizes multiple fitness functions that encode the attributes of the desired dose distribution for the PTV and OARs. The graphical interfaces within PARETO provide useful information such as: the convergence behavior during optimization, trade-off plots between the competing objectives, and a graphical representation of the optimal solution database allowing for the rapid exploration of treatment plan quality through the evaluation of dose-volume histograms and isodose distributions. PARETO was evaluated for two relatively complex clinical cases, a paranasal sinus and a pancreas case. The end result of each PARETO run was a database of optimal (non-dominated) treatment plans that demonstrated trade-offs between the OAR and PTV fitness functions, which were all equally good in the Pareto-optimal sense (where no one objective can be improved without worsening at least one other). Ferret was able to produce high quality solutions even though a large number of parameters, such as beam fluence and beam angles, were included in the optimization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J; Molecular Imaging Program at Stanford, Stanford, CA; Bio-X Program, Stanford, CA
2015-06-15
Purpose: To evaluate radiation responses of the medulloblastoma cell line Daoy in intensity-modulated radiation therapy (IMRT), quantitative variations to variable radiation dosimetic parameters were tracked by bioluminescent images (BLIs). Methods: The luciferase and green fluorescent protein positive Daoy cells were cultured on dishes. The medulloblastoma cells irradiated to different dose rate, interval of fractionated doses, field margin and misalignment, and dose uniformity in IMRT were monitored using bioluminescent images. The cultured cells were placed into a dedicated acrylic phantom to deliver intensity-modulated fluences and calculate accurate predicted dose distribution. The radiation with dose rate from 0.5 Gy/min to 15 Gy/minmore » was irradiated by adjusting monitor unit per minute and source-to-surface distances. The intervals of fractionated dose delivery were changed considering the repair time of double strand breaks (DSB) revealed by straining of gamma-H2AX.The effect of non-uniform doses on the cells were visualized by registering dose distributions and BLIs. The viability according to dosimetric parameters was correlated with bioluminescent intensities for cross-check of radiation responses. Results: The DSB and cell responses due to the first fractionated dose delivery significantly affected final tumor control rather than other parameters. The missing tumor volumes due to the smaller field margin than the tumor periphery or field misalignment caused relapse of cell responses on BLIs. The dose rate and gradient had effect on initial responses but could not bring out the distinguishable killing effect on cancer cells. Conclusion: Visualized and quantified bioluminescent images were useful to correlate the dose distributions with spatial radiation effects on cells. This would derive the effective combination of dose delivery parameters and fractionation. Radiation responses in particular IMRT configuration could be reflected to image based-dose re-optimization.« less
TU-G-201-02: An MRI Simulator From Proposal to Operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao, Y.
2015-06-15
This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, andmore » potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Penninkhof, Joan, E-mail: j.penninkhof@erasmusmc.nl; Spadola, Sara; Department of Physics and Astronomy, Alma Mater Studiorum, University of Bologna, Bologna
Purpose and Objective: Propose a novel method for individualized selection of beam angles and treatment isocenter in tangential breast intensity modulated radiation therapy (IMRT). Methods and Materials: For each patient, beam and isocenter selection starts with the fully automatic generation of a large database of IMRT plans (up to 847 in this study); each of these plans belongs to a unique combination of isocenter position, lateral beam angle, and medial beam angle. The imposed hard planning constraint on patient maximum dose may result in plans with unacceptable target dose delivery. Such plans are excluded from further analyses. Owing to differencesmore » in beam setup, database plans differ in mean doses to organs at risk (OARs). These mean doses are used to construct 2-dimensional graphs, showing relationships between: (1) contralateral breast dose and ipsilateral lung dose; and (2) contralateral breast dose and heart dose (analyzed only for left-sided). The graphs can be used for selection of the isocenter and beam angles with the optimal, patient-specific tradeoffs between the mean OAR doses. For 30 previously treated patients (15 left-sided and 15 right-sided tumors), graphs were generated considering only the clinically applied isocenter with 121 tangential beam angle pairs. For 20 of the 30 patients, 6 alternative isocenters were also investigated. Results: Computation time for automatic generation of 121 IMRT plans took on average 30 minutes. The generated graphs demonstrated large variations in tradeoffs between conflicting OAR objectives, depending on beam angles and patient anatomy. For patients with isocenter optimization, 847 IMRT plans were considered. Adding isocenter position optimization next to beam angle optimization had a small impact on the final plan quality. Conclusion: A method is proposed for individualized selection of beam angles in tangential breast IMRT. This may be especially important for patients with cardiac risk factors or an enhanced risk for the development of contralateral breast cancer.« less
SU-E-T-551: Monitor Unit Optimization in Stereotactic Body Radiation Therapy for Stage I Lung Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, B-T; Lu, J-Y
2015-06-15
Purpose: The study aims to reduce the monitor units (MUs) in the stereotactic body radiation therapy (SBRT) treatment for lung cancer by adjusting the optimizing parameters. Methods: Fourteen patients suffered from stage I Non-Small Cell Lung Cancer (NSCLC) were enrolled. Three groups of parameters were adjusted to investigate their effects on MU numbers and organs at risk (OARs) sparing: (1) the upper objective of planning target volume (UOPTV); (2) strength setting in the MU constraining objective; (3) max MU setting in the MU constraining objective. Results: We found that the parameters in the optimizer influenced the MU numbers in amore » priority, strength and max MU dependent manner. MU numbers showed a decreasing trend with the UOPTV increasing. MU numbers with low, medium and high priority for the UOPTV were 428±54, 312±48 and 258±31 MU/Gy, respectively. High priority for UOPTV also spared the heart, cord and lung while maintaining comparable PTV coverage than the low and medium priority group. It was observed that MU numbers tended to decrease with the strength increasing and max MU setting decreasing. With maximum strength, the MU numbers reached its minimum while maintaining comparable or improved dose to the normal tissues. It was also found that the MU numbers continued to decline at 85% and 75% max MU setting but no longer to decrease at 50% and 25%. Combined with high priority for UOPTV and MU constraining objectives, the MU numbers can be decreased as low as 223±26 MU/Gy. Conclusion:: The priority of UOPTV, MU constraining objective in the optimizer impact on the MU numbers in SBRT treatment for lung cancer. Giving high priority to the UOPTV, setting the strength to maximum value and the max MU to 50% in the MU objective achieves the lowest MU numbers while maintaining comparable or improved OAR sparing.« less
NASA Astrophysics Data System (ADS)
Hwang, Taejin; Kim, Yong Nam; Kim, Soo Kon; Kang, Sei-Kwon; Cheong, Kwang-Ho; Park, Soah; Yoon, Jai-Woong; Han, Taejin; Kim, Haeyoung; Lee, Meyeon; Kim, Kyoung-Joo; Bae, Hoonsik; Suh, Tae-Suk
2015-06-01
The dose constraint during prostate intensity-modulated radiation therapy (IMRT) optimization should be patient-specific for better rectum sparing. The aims of this study are to suggest a novel method for automatically generating a patient-specific dose constraint by using an experience-based dose volume histogram (DVH) of the rectum and to evaluate the potential of such a dose constraint qualitatively. The normal tissue complication probabilities (NTCPs) of the rectum with respect to V %ratio in our study were divided into three groups, where V %ratio was defined as the percent ratio of the rectal volume overlapping the planning target volume (PTV) to the rectal volume: (1) the rectal NTCPs in the previous study (clinical data), (2) those statistically generated by using the standard normal distribution (calculated data), and (3) those generated by combining the calculated data and the clinical data (mixed data). In the calculated data, a random number whose mean value was on the fitted curve described in the clinical data and whose standard deviation was 1% was generated by using the `randn' function in the MATLAB program and was used. For each group, we validated whether the probability density function (PDF) of the rectal NTCP could be automatically generated with the density estimation method by using a Gaussian kernel. The results revealed that the rectal NTCP probability increased in proportion to V %ratio , that the predictive rectal NTCP was patient-specific, and that the starting point of IMRT optimization for the given patient might be different. The PDF of the rectal NTCP was obtained automatically for each group except that the smoothness of the probability distribution increased with increasing number of data and with increasing window width. We showed that during the prostate IMRT optimization, the patient-specific dose constraints could be automatically generated and that our method could reduce the IMRT optimization time as well as maintain the IMRT plan quality.
Potential role of the glycolytic oscillator in acute hypoxia in tumors
NASA Astrophysics Data System (ADS)
Che Fru, Leonard; Adamson, Erin B.; Campos, David D.; Fain, Sean B.; Jacques, Steven L.; van der Kogel, Albert J.; Nickel, Kwang P.; Song, Chihwa; Kimple, Randall J.; Kissick, Michael W.
2015-12-01
Tumor acute hypoxia has a dynamic component that is also, at least partially, coherent. Using blood oxygen level dependent magnetic resonance imaging, we observed coherent oscillations in hemoglobin saturation dynamics in cell line xenograft models of head and neck squamous cell carcinoma. We posit a well-established biochemical nonlinear oscillatory mechanism called the glycolytic oscillator as a potential cause of the coherent oscillations in tumors. These data suggest that metabolic changes within individual tumor cells may affect the local tumor microenvironment including oxygen availability and therefore radiosensitivity. These individual cells can synchronize the oscillations in patches of similar intermediate glucose levels. These alterations have potentially important implications for radiation therapy and are a potential target for optimizing the cancer response to radiation.
Radiotherapy-induced Cherenkov luminescence imaging in a human body phantom.
Ahmed, Syed Rakin; Jia, Jeremy Mengyu; Bruza, Petr; Vinogradov, Sergei; Jiang, Shudong; Gladstone, David J; Jarvis, Lesley A; Pogue, Brian W
2018-03-01
Radiation therapy produces Cherenkov optical emission in tissue, and this light can be utilized to activate molecular probes. The feasibility of sensing luminescence from a tissue molecular oxygen sensor from within a human body phantom was examined using the geometry of the axillary lymph node region. Detection of regions down to 30-mm deep was feasible with submillimeter spatial resolution with the total quantity of the phosphorescent sensor PtG4 near 1 nanomole. Radiation sheet scanning in an epi-illumination geometry provided optimal coverage, and maximum intensity projection images provided illustration of the concept. This work provides the preliminary information needed to attempt this type of imaging in vivo. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Albuquerque, Kevin; Tell, Dina; Lobo, Philip; Millbrandt, Linda; Mathews, Herbert L; Janusek, Linda Witek
2012-06-18
This pilot study used a prospective longitudinal design to compare the effect of adjuvant whole breast radiation therapy (WBRT) versus partial breast radiation therapy (PBRT) on fatigue, perceived stress, quality of life and natural killer cell activity (NKCA) in women receiving radiation after breast cancer surgery. Women (N = 30) with early-stage breast cancer received either PBRT, Mammosite brachytherapy at dose of 34 Gy 10 fractions/5 days, (N = 15) or WBRT, 3-D conformal techniques at dose of 50 Gy +10 Gy Boost/30 fractions, (N = 15). Treatment was determined by the attending oncologist after discussion with the patient and the choice was based on tumor stage and clinical need. Women were assessed prior to initiation of radiation therapy and twice after completion of radiation therapy. At each assessment, blood was obtained for determination of NKCA and the following instruments were administered: Perceived Stress Scale (PSS), Functional Assessment of Cancer Therapy-Fatigue (FACT-F), and Functional Assessment of Cancer Therapy-General (FACT-G). Hierarchical linear modeling (HLM) was used to evaluate group differences in initial outcomes and change in outcomes over time. Fatigue (FACT-F) levels, which were similar prior to radiation therapy, demonstrated a significant difference in trajectory. Women who received PBRT reported progressively lower fatigue; conversely fatigue worsened over time for women who received WBRT. No difference in perceived stress was observed between women who received PBRT or WBRT. Both groups of women reported similar levels of quality of life (FACT-G) prior to initiation of radiation therapy. However, HLM analysis revealed significant group differences in the trajectory of quality of life, such that women receiving PBRT exhibited a linear increase in quality of life over time after completion of radiation therapy; whereas women receiving WBRT showed a decreasing trajectory. NKCA was also similar between therapy groups but additional post hoc analysis revealed that better quality of life significantly predicted higher NKCA regardless of therapy. Compared to WBRT, PBRT results in more rapid recovery from cancer-related fatigue with improved restoration of quality of life after radiation therapy. Additionally, better quality of life predicts higher NKCA against tumor targets, emphasizing the importance of fostering quality of life for women undergoing adjuvant radiation therapy.
Radiation therapy in early-stage invasive breast cancer.
Lin, Ray; Tripuraneni, Prabhakar
2011-06-01
The treatment of breast cancer involves a multi-disciplinary approach with radiation therapy playing a key role. Breast-conserving surgery has been an option for women with early-stage breast cancer for over two decades now. Multiple randomized trials now have demonstrated the efficacy of breast-conserving surgery followed by radiation therapy. With the advancements in breast imaging and the successful campaign for early detection of breast cancer, more women today are found to have early-stage small breast cancers. Patient factors (breast size, tumor location, history of prior radiation therapy, preexisting conditions such as collagen vascular disease, age, having prosthetically augmented breasts), pathological factors (margin status, tumor size, presence of extensive intraductal component requiring multiple surgical excisions), as well as patient preference are all taken into consideration prior to surgical management of breast cancer. Whole-breast fractionated radiation therapy between 5 and 7 weeks is considered as the standard of care treatment following breast-conserving surgery. However, new radiation treatment strategies have been developed in recent years to provide alternatives to the conventional 5-7 week whole-breast radiation therapy for some patients. Accelerated partial breast radiation therapy (APBI) was introduced because the frequency of breast recurrences outside of the surgical cavity has been shown to be low. This technique allows treatments to be delivered quicker (usually 1 week, twice daily) to a limited volume. Often times, this treatment involves the use of a brachytherapy applicator to be placed into the surgical cavity following breast-conserving surgery. Accelerated hypofractionated whole-breast irradiation may be another faster way to deliver radiation therapy following breast-conserving surgery. This journal article reviews the role of radiation therapy in women with early-stage breast cancer addressing patient selection in breast-conserving therapy, a review of pertinent trials in breast-conserving therapy, as well as the different treatment techniques available to women following breast-conserving surgery.
Concurrent apatinib and local radiation therapy for advanced gastric cancer
Zhang, Ming; Deng, Weiye; Cao, Xiaoci; Shi, Xiaoming; Zhao, Huanfen; Duan, Zheping; Lv, Bonan; Liu, Bin
2017-01-01
Abstract Rationale: Apatinib is a novel anti-angiogenic agent targeting vascular endothelial growth factor receptor-2, which is effective in patients with chemotherapy-refractory gastric cancer. There are no reports of concurrent apatinib with local radiation therapy in elderly patients with advanced gastric cancer. Patient concerns and Diagnoses: we present the first published report of a 70-year-old male patient with advanced gastric cancer who received concurrent apatinib and local radiation therapy after failure of oxaliplatin and S-1 chemotherapy. Interventions and Outcomes: The patient received concurrent apatinib and local radiation therapy and was followed up 7 months after therapy without disease progress, 14 months later indicated extensive metastasis and this patient died of pulmonary infection. Lessons: Elderly patients with advanced gastric cancer may benefit from concurrent apatinib with local radiation therapy when chemotherapy is not tolerated or successful. Further studies are needed to investigate the clinical outcomes and toxicities associated with concurrent apatinib and radiation therapy in gastric cancer. PMID:28248891
Zhang, Ming; Deng, Weiye; Cao, Xiaoci; Shi, Xiaoming; Zhao, Huanfen; Duan, Zheping; Lv, Bonan; Liu, Bin
2017-03-01
Apatinib is a novel anti-angiogenic agent targeting vascular endothelial growth factor receptor-2, which is effective in patients with chemotherapy-refractory gastric cancer. There are no reports of concurrent apatinib with local radiation therapy in elderly patients with advanced gastric cancer. PATIENT CONCERNS AND DIAGNOSES:: we present the first published report of a 70-year-old male patient with advanced gastric cancer who received concurrent apatinib and local radiation therapy after failure of oxaliplatin and S-1 chemotherapy. The patient received concurrent apatinib and local radiation therapy and was followed up 7 months after therapy without disease progress, 14 months later indicated extensive metastasis and this patient died of pulmonary infection. Elderly patients with advanced gastric cancer may benefit from concurrent apatinib with local radiation therapy when chemotherapy is not tolerated or successful. Further studies are needed to investigate the clinical outcomes and toxicities associated with concurrent apatinib and radiation therapy in gastric cancer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, B; Rao, Y; Tsien, C
Purpose: To implement the Gradient Echo Plural Contrast Imaging(GEPCI) technique in MRI-simulation for radiation therapy and assess the feasibility of using GEPCI images with advanced inhomogeneity correction in MRI-guided radiotherapy for brain treatment. Methods: An optimized multigradient-echo GRE sequence (TR=50ms;TE1=4ms;delta-TE=4ms;flip angle=300,11 Echoes) was developed to generate both structural (T1w and T2*w) and functional MRIs (field and susceptibility maps) from a single acquisition. One healthy subject (Subject1) and one post-surgical brain cancer patient (Subject2) were scanned on a Philips Ingenia 1.5T MRI used for radiation therapy simulation. Another healthy subject (Subject3) was scanned on a 0.35T MRI-guided radiotherapy (MR-IGRT) system (ViewRay).more » A voxel spread function (VSF) was used to correct the B0 inhomogeneities caused by surgical cavities and edema for Subject2. GEPCI images and standard radiotherapy planning MRIs for this patient were compared focusing the delineation of radiotherapy target region. Results: GEPCI brain images were successfully derived from all three subjects with scan times of <7 minutes. The images derived for Subjects1&2 demonstrated that GEPCI can be applied and combined into radiotherapy MRI simulation. Despite low field, T1-weighted and R2* images were successfully reconstructed for Subject3 and were satisfactory for contour and target delineation. The R2* distribution of grey matter (center=12,FWHM=4.5) and white matter (center=14.6, FWHM=2) demonstrated the feasibility for tissue segmentation and quantification. The voxel spread function(VSF) corrected surgical site related inhomogeneities for Subject2. R2* and quantitative susceptibility map(QSM) images for Subject2 can be used to quantitatively assess the brain structure response to radiation over the treatment course. Conclusion: We implemented the GEPCI technique in MRI-simulation and in MR-IGRT system for radiation therapy. The images demonstrated that it is feasible to adopt this technique in radiotherapy for structural delineation. The preliminary data also enable the opportunity for quantitative assessment of radiation response of the target region and normal tissue.« less
The concept and evolution of involved site radiation therapy for lymphoma.
Specht, Lena; Yahalom, Joachim
2015-10-01
We describe the development of radiation therapy for lymphoma from extended field radiotherapy of the past to modern conformal treatment with involved site radiation therapy based on advanced imaging, three-dimensional treatment planning and advanced treatment delivery techniques. Today, radiation therapy is part of the multimodality treatment of lymphoma, and the irradiated tissue volume is much smaller than before, leading to highly significant reductions in the risks of long-term complications.
Enhancement of Radiation Therapy in Prostate Cancer by DNA-PKcs Inhibitor
2012-07-01
Award Number: W81XWH-11-1-0270 TITLE: Enhancement of Radiation Therapy in Prostate Cancer by DNA-PKcs Inhibitor PRINCIPAL INVESTIGATOR...TITLE AND SUBTITLE Enhancement of Radiation Therapy in Prostate Cancer by 5a. CONTRACT NUMBER DNA-PKcs Inhibitor 5b. GRANT NUMBER W81XWH-11-1-0270...the treatment of localized prostate cancer . However, a proportion of locally advanced cancers develop radiation resistance and recur after therapy
Automatic learning-based beam angle selection for thoracic IMRT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amit, Guy; Marshall, Andrea; Purdie, Thomas G., E-mail: tom.purdie@rmp.uhn.ca
Purpose: The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process, which requires the planner to iterate between choosing beam angles, specifying dose–volume objectives and executing IMRT optimization. In thorax treatment planning, where there are no class solutions for beam placement, beam angle selection is performed manually, based on the planner’s clinical experience. The purpose of this work is to propose and study a computationallymore » efficient framework that utilizes machine learning to automatically select treatment beam angles. Such a framework may be helpful for reducing the overall planning workload. Methods: The authors introduce an automated beam selection method, based on learning the relationships between beam angles and anatomical features. Using a large set of clinically approved IMRT plans, a random forest regression algorithm is trained to map a multitude of anatomical features into an individual beam score. An optimization scheme is then built to select and adjust the beam angles, considering the learned interbeam dependencies. The validity and quality of the automatically selected beams evaluated using the manually selected beams from the corresponding clinical plans as the ground truth. Results: The analysis included 149 clinically approved thoracic IMRT plans. For a randomly selected test subset of 27 plans, IMRT plans were generated using automatically selected beams and compared to the clinical plans. The comparison of the predicted and the clinical beam angles demonstrated a good average correspondence between the two (angular distance 16.8° ± 10°, correlation 0.75 ± 0.2). The dose distributions of the semiautomatic and clinical plans were equivalent in terms of primary target volume coverage and organ at risk sparing and were superior over plans produced with fixed sets of common beam angles. The great majority of the automatic plans (93%) were approved as clinically acceptable by three radiation therapy specialists. Conclusions: The results demonstrated the feasibility of utilizing a learning-based approach for automatic selection of beam angles in thoracic IMRT planning. The proposed method may assist in reducing the manual planning workload, while sustaining plan quality.« less
Radiation therapy facilities in the United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ballas, Leslie K.; Elkin, Elena B.; Schrag, Deborah
2006-11-15
Purpose: About half of all cancer patients in the United States receive radiation therapy as a part of their cancer treatment. Little is known, however, about the facilities that currently deliver external beam radiation. Our goal was to construct a comprehensive database of all radiation therapy facilities in the United States that can be used for future health services research in radiation oncology. Methods and Materials: From each state's health department we obtained a list of all facilities that have a linear accelerator or provide radiation therapy. We merged these state lists with information from the American Hospital Association (AHA),more » as well as 2 organizations that audit the accuracy of radiation machines: the Radiologic Physics Center (RPC) and Radiation Dosimetry Services (RDS). The comprehensive database included all unique facilities listed in 1 or more of the 4 sources. Results: We identified 2,246 radiation therapy facilities operating in the United States as of 2004-2005. Of these, 448 (20%) facilities were identified through state health department records alone and were not listed in any other data source. Conclusions: Determining the location of the 2,246 radiation facilities in the United States is a first step in providing important information to radiation oncologists and policymakers concerned with access to radiation therapy services, the distribution of health care resources, and the quality of cancer care.« less
Computed Tomography Density Change in the Thyroid Gland Before and After Radiation Therapy.
Ishibashi, Naoya; Maebayashi, Toshiya; Aizawa, Takuya; Sakaguchi, Masakuni; Okada, Masahiro; Matsushita, Junichi
2018-01-01
Hypothyroidism is an established adverse effect of radiation therapy for head and neck cancer, and computed tomography (CT) density of the thyroid gland is lower in hypothyroid than euthyroid individuals. No previous studies have evaluated changes in CT densities of the thyroid gland caused by radiation therapy. The aim was to investigate the relationship between the change in CT density of the thyroid gland before and after radiation therapy for head and neck cancer and hypothyroidism. This retrospective study analyzed data of 24 patients treated by radiation therapy for head and neck cancers. After dosimetric analysis of received radiation therapy, a Picture Archiving and Communication System was used to manually contour the thyroid on pre-treatment CT images to enable determination of mean thyroid gland CT densities and received radiation doses. Pre- and post-treatment thyroid function was assessed on the basis of serum TSH concentrations. Multivariate and univariate analyses were used to determine what clinical factors are associated with post-radiation therapy decrease in CT density of the thyroid and Pearson's χ 2 test was used to assess correlations between these densities and TSH concentrations. Mean CT densities of the thyroid gland decreased from before to after radiation therapy in 73.9% of our patients (median decrease 16.8 HU). Serum TSH concentrations were significantly higher in patients with greater then median decreases in CT density than in those with lesser or no decreases. Post-radiation therapy hypothyroidism may be predicted by significant decreases in CT density of the thyroid gland. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pinkham, Mark B., E-mail: mark.pinkham@health.qld.gov.au; University of Queensland, Brisbane; Foote, Matthew C.
Purpose: To describe the anatomic distribution of regionally recurrent disease in patients with stage III melanoma in the axilla after curative-intent surgery with and without adjuvant radiation therapy. Methods and Materials: A single-institution, retrospective analysis of a prospective database of 277 patients undergoing curative-intent treatment for stage III melanoma in the axilla between 1992 and 2012 was completed. For patients who received radiation therapy and those who did not, patterns of regional recurrence were analyzed, and univariate analyses were performed to assess for potential factors associated with location of recurrence. Results: There were 121 patients who received adjuvant radiation therapymore » because their clinicopathologic features conferred a greater risk of regional recurrence. There were 156 patients who received no radiation therapy. The overall axillary control rate was 87%. There were 37 patients with regional recurrence; 17 patients had received adjuvant radiation therapy (14%), and 20 patients (13%) had not. The likelihood of in-field nodal recurrence was significantly less in the adjuvant radiation therapy group (P=.01) and significantly greater in sites adjacent to the axilla (P=.02). Patients with high-risk clinicopathologic features who did not receive adjuvant radiation therapy also tended to experience in-field failure rather than adjacent-field failure. Conclusions: Patients who received adjuvant radiation therapy were more likely to experience recurrence in the adjacent-field regions rather than in the in-field regions. This may not simply reflect higher-risk pathology. Using this data, it may be possible to improve outcomes by reducing the number of adjacent-field recurrences after adjuvant radiation therapy.« less
Roberts, Kenneth B; Soulos, Pamela R; Herrin, Jeph; Yu, James B; Long, Jessica B; Dostaler, Edward; Gross, Cary P
2013-04-01
New radiation therapy modalities have broadened treatment options for older women with breast cancer, but it is unclear how clinical factors, geographic region, and physician preference affect the choice of radiation therapy modality. We used the Surveillance, Epidemiology, and End Results-Medicare database to identify women diagnosed with stage I-III breast cancer from 1998 to 2007 who underwent breast-conserving surgery. We assessed the temporal trends in, and costs of, the adoption of intensity modulated radiation therapy (IMRT) and brachytherapy. Using hierarchical logistic regression, we evaluated the relationship between the use of these new modalities and patient and regional characteristics. Of 35,060 patients, 69.9% received conventional external beam radiation therapy (EBRT). Although overall radiation therapy use remained constant, the use of IMRT increased from 0.0% to 12.6% from 1998 to 2007, and brachytherapy increased from 0.7% to 9.0%. The statistical variation in brachytherapy use attributable to the radiation oncologist and geographic region was 41.4% and 9.5%, respectively (for IMRT: 23.8% and 22.1%, respectively). Women undergoing treatment at a free-standing radiation facility were significantly more likely to receive IMRT than were women treated at a hospital-based facility (odds ratio for IMRT vs EBRT: 3.89 [95% confidence interval, 2.78-5.45]). No such association was seen for brachytherapy. The median radiation therapy cost per treated patient increased from $5389 in 2001 to $8539 in 2007. IMRT and brachytherapy use increased substantially from 1998 to 2007; overall, radiation therapy costs increased by more than 50%. Radiation oncologists played an important role in treatment choice for both types of radiation therapy, whereas geographic region played a bigger role in the use of IMRT than brachytherapy. Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, Kenneth B.; Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut; Soulos, Pamela R.
2013-04-01
Purpose: New radiation therapy modalities have broadened treatment options for older women with breast cancer, but it is unclear how clinical factors, geographic region, and physician preference affect the choice of radiation therapy modality. Methods and Materials: We used the Surveillance, Epidemiology, and End Results-Medicare database to identify women diagnosed with stage I-III breast cancer from 1998 to 2007 who underwent breast-conserving surgery. We assessed the temporal trends in, and costs of, the adoption of intensity modulated radiation therapy (IMRT) and brachytherapy. Using hierarchical logistic regression, we evaluated the relationship between the use of these new modalities and patient andmore » regional characteristics. Results: Of 35,060 patients, 69.9% received conventional external beam radiation therapy (EBRT). Although overall radiation therapy use remained constant, the use of IMRT increased from 0.0% to 12.6% from 1998 to 2007, and brachytherapy increased from 0.7% to 9.0%. The statistical variation in brachytherapy use attributable to the radiation oncologist and geographic region was 41.4% and 9.5%, respectively (for IMRT: 23.8% and 22.1%, respectively). Women undergoing treatment at a free-standing radiation facility were significantly more likely to receive IMRT than were women treated at a hospital-based facility (odds ratio for IMRT vs EBRT: 3.89 [95% confidence interval, 2.78-5.45]). No such association was seen for brachytherapy. The median radiation therapy cost per treated patient increased from $5389 in 2001 to $8539 in 2007. Conclusions: IMRT and brachytherapy use increased substantially from 1998 to 2007; overall, radiation therapy costs increased by more than 50%. Radiation oncologists played an important role in treatment choice for both types of radiation therapy, whereas geographic region played a bigger role in the use of IMRT than brachytherapy.« less
[The results of strontium-90 contact therapy to prevent the recurrence of pterygium].
Schultze, J; Hinrichs, M; Kimmig, B
1996-08-01
Aim of the study was the evaluation of the role of adjuvant radiation therapy in the prevention of recurrence after excision. Between July 1, 1985 and April 1, 1993, 64 patients (43 male, 21 female) were referred to radiation therapy after excision of a nasal pterygium. Radiation therapy was done with a strontium-90 eye applicator and a total dose of 30 Gy, fractionated in 6 fractions of 5 Gy each, 3 times a week. Forty-nine patients were treated primarily, 15 patients underwent radiation therapy for the first time in case of recurrent pterygium after multiple re-excisions. All patients had a following of 1 to 9 years with a median of 5.5 years. In 8 of 64 irradiated patients recurrent pterygium was detected (12.5%). Differentiated into the 2 groups 4 of the primarily treated patients had recurrent pterygium (8.16%), the other 4 were in the group with multiple former re-excisions (26.7%). With regard to the initiation of the irradiation after surgery pterygium did not recur in any of the primarily treated patients who were irradiated in between 3 days after surgery. In contrary 3 of 7 primarily treated patients (42.9%) who started radiation therapy between 7 and 10 days after surgery had recurrent pterygium. For the patients with primarily recurrent pterygium no dependence of the initiation of radiation therapy after surgery could be detected. Adjuvant radiation therapy after excision of pterygium lowers the rate of recurrence from about 40% to 12.5%, in a primarily adjuvant situation to 8.16%. In these patients radiation therapy should be initiated within 3 days after surgery. Patients with primarily recurrent pterygium have an elevated risk of recurrence independently of the initiation of radiation therapy.
Fan, Qiyong; Nanduri, Akshay; Yang, Jaewon; Yamamoto, Tokihiro; Loo, Billy; Graves, Edward; Zhu, Lei; Mazin, Samuel
2013-01-01
Purpose: Emission guided radiation therapy (EGRT) is a new modality that uses PET emissions in real-time for direct tumor tracking during radiation delivery. Radiation beamlets are delivered along positron emission tomography (PET) lines of response (LORs) by a fast rotating ring therapy unit consisting of a linear accelerator (Linac) and PET detectors. The feasibility of tumor tracking and a primitive modulation method to compensate for attenuation have been demonstrated using a 4D digital phantom in our prior work. However, the essential capability of achieving dose modulation as in conventional intensity modulated radiation therapy (IMRT) treatments remains absent. In this work, the authors develop a planning scheme for EGRT to accomplish sophisticated intensity modulation based on an IMRT plan while preserving tumor tracking. Methods: The planning scheme utilizes a precomputed LOR response probability distribution to achieve desired IMRT planning modulation with effects of inhomogeneous attenuation and nonuniform background activity distribution accounted for. Evaluation studies are performed on a 4D digital patient with a simulated lung tumor and a clinical patient who has a moving breast cancer metastasis in the lung. The Linac dose delivery is simulated using a voxel-based Monte Carlo algorithm. The IMRT plan is optimized for a planning target volume (PTV) that encompasses the tumor motion using the MOSEK package and a Pinnacle3™ workstation (Philips Healthcare, Fitchburg, WI) for digital and clinical patients, respectively. To obtain the emission data for both patients, the Geant4 application for tomographic emission (GATE) package and a commercial PET scanner are used. As a comparison, 3D and helical IMRT treatments covering the same PTV based on the same IMRT plan are simulated. Results: 3D and helical IMRT treatments show similar dose distribution. In the digital patient case, compared with the 3D IMRT treatment, EGRT achieves a 15.1% relative increase in dose to 95% of the gross tumor volume (GTV) and a 31.8% increase to 50% of the GTV. In the patient case, EGRT yields a 15.2% relative increase in dose to 95% of the GTV and a 20.7% increase to 50% of the GTV. The organs at risk (OARs) doses are kept similar or lower for EGRT in both cases. Tumor tracking is observed in the presence of planning modulation in all EGRT treatments. Conclusions: As compared to conventional IMRT treatments, the proposed EGRT planning scheme allows an escalated target dose while keeping dose to the OARs within the same planning limits. With the capabilities of incorporating planning modulation and accurate tumor tracking, EGRT has the potential to greatly improve targeting in radiation therapy and enable a practical and effective implementation of 4D radiation therapy for planning and delivery. PMID:23927305
A review of the biological and clinical aspects of radiation caries.
Aguiar, Gabrielle P; Jham, Bruno C; Magalhães, Cláudia S; Sensi, Luis Guilherme; Freire, Addah R
2009-07-01
The aim of this article is to review the clinical and biological features underlying the development and progression of radiation caries. Although radiotherapy (RT) plays an important role in the management of patients with head and neck cancer (HNC), it is also associated with several undesired side effects such as radiation caries which is a common, yet serious, complication. To review the condition, the Pubmed database was searched using the keywords "radiotherapy," "radiation," "caries," "hyposalivation," "prevention" and "management". Only studies published in the English language were selected. Cross-referencing identified additionally relevant studies. RT leads to alterations in the dentition, saliva, oral microflora, and diet of patients. Consequently, irradiated patients are at increased risk for the development of a rapid, rampant carious process known as radiation caries. Motivation of patients, adequate plaque control, stimulation of salivary flow, fluoride use, and nutritional orientation are essential to reduce the incidence of radiation caries and ultimately improve the quality of life for HNC patients. Radiation caries is an aggressive side effect of RT. Dentists play an important role in the prevention of the condition via comprehensive oral healthcare before, during, and after the active cancer therapy. Dentists should understand the clinical and biological aspects underlying radiation caries to prevent the development of lesions and provide optimal treatment when needed.
Rancilio, Nicholas J; Custead, Michelle R; Poulson, Jean M
2016-09-01
A 5-year-old spayed female Shih Tzu was referred for evaluation of a nasal transitional carcinoma. A total lifetime dose of 117 Gy was delivered to the intranasal mass in three courses over nearly 2 years using fractionated intensity modulated radiation therapy (IMRT) to spare normal tissues. Clinically significant late normal tissue side effects were limited to bilaterally diminished tear production. The patient died of metastatic disease progression 694 days after completion of radiation therapy course 1. This case demonstrates that retreatment with radiation therapy to high lifetime doses for recurrent local disease may be well tolerated with IMRT. © 2016 American College of Veterinary Radiology.
Yoshimura, Takaaki; Kinoshita, Rumiko; Onodera, Shunsuke; Toramatsu, Chie; Suzuki, Ryusuke; Ito, Yoichi M; Takao, Seishin; Matsuura, Taeko; Matsuzaki, Yuka; Umegaki, Kikuo; Shirato, Hiroki; Shimizu, Shinichi
2016-09-01
This treatment planning study was conducted to determine whether spot scanning proton beam therapy (SSPT) reduces the risk of grade ⩾3 hematologic toxicity (HT3+) compared with intensity modulated radiation therapy (IMRT) for postoperative whole pelvic radiation therapy (WPRT). The normal tissue complication probability (NTCP) of the risk of HT3+ was used as an in silico surrogate marker in this analysis. IMRT and SSPT plans were created for 13 gynecologic malignancy patients who had received hysterectomies. The IMRT plans were generated using the 7-fields step and shoot technique. The SSPT plans were generated using anterior-posterior field with single field optimization. Using the relative biological effectives (RBE) value of 1.0 for IMRT and 1.1 for SSPT, the prescribed dose was 45Gy(RBE) in 1.8Gy(RBE) per fractions for 95% of the planning target volume (PTV). The homogeneity index (HI) and the conformity index (CI) of the PTV were also compared. The bone marrow (BM) and femoral head doses using SSPT were significantly lower than with IMRT. The NTCP modeling analysis showed that the risk of HT3+ using SSPT was significantly lower than with IMRT (NTCP=0.04±0.01 and 0.19±0.03, p=0.0002, respectively). There were no significant differences in the CI and HI of the PTV between IMRT and SSPT (CI=0.97±0.01 and 0.96±0.02, p=0.3177, and HI=1.24±0.11 and 1.27±0.05, p=0.8473, respectively). The SSPT achieves significant reductions in the dose to BM without compromising target coverage, compared with IMRT. The NTCP value for HT3+ in SSPT was significantly lower than in IMRT. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Battista, Jerry J; Johnson, Carol; Turnbull, David; Kempe, Jeff; Bzdusek, Karl; Van Dyk, Jacob; Bauman, Glenn
2013-12-01
To examine a range of scenarios for image-guided adaptive radiation therapy of prostate cancer, including different schedules for megavoltage CT imaging, patient repositioning, and dose replanning. We simulated multifraction dose distributions with deformable registration using 35 sets of megavoltage CT scans of 13 patients. We computed cumulative dose-volume histograms, from which tumor control probabilities and normal tissue complication probabilities (NTCPs) for rectum were calculated. Five-field intensity modulated radiation therapy (IMRT) with 18-MV x-rays was planned to achieve an isocentric dose of 76 Gy to the clinical target volume (CTV). The differences between D95, tumor control probability, V70Gy, and NTCP for rectum, for accumulated versus planned dose distributions, were compared for different target volume sizes, margins, and adaptive strategies. The CTV D95 for IMRT treatment plans, averaged over 13 patients, was 75.2 Gy. Using the largest CTV margins (10/7 mm), the D95 values accumulated over 35 fractions were within 2% of the planned value, regardless of the adaptive strategy used. For tighter margins (5 mm), the average D95 values dropped to approximately 73.0 Gy even with frequent repositioning, and daily replanning was necessary to correct this deficit. When personalized margins were applied to an adaptive CTV derived from the first 6 treatment fractions using the STAPLE (Simultaneous Truth and Performance Level Estimation) algorithm, target coverage could be maintained using a single replan 1 week into therapy. For all approaches, normal tissue parameters (rectum V(70Gy) and NTCP) remained within acceptable limits. The frequency of adaptive interventions depends on the size of the CTV combined with target margins used during IMRT optimization. The application of adaptive target margins (<5 mm) to an adaptive CTV determined 1 week into therapy minimizes the need for subsequent dose replanning. Copyright © 2013 Elsevier Inc. All rights reserved.
Krayenbuehl, J; Di Martino, M; Guckenberger, M; Andratschke, N
2017-10-02
Whole-brain radiation therapy (WBRT) with hippocampus sparing (HS) has been investigated by the radiation oncology working group (RTOG) 0933 trial for patients with multiple brain metastases. They showed a decrease of adverse neurocognitive effects with HS WBRT compared to WBRT alone. With the development of automated treatment planning system (aTPS) in the last years, a standardization of the plan quality at a high level was achieved. The goal of this study was to evaluate the feasibility of using an aTPS for the treatment of HS WBRT and see if the RTOG 0933 dose constraints could be achieved and improved. Ten consecutive patients treated with HS WBRT were enrolled in this study. 10 × 3 Gy was prescribed according to the RTOG 0933 protocol to 92% of the target volume (whole-brain excluding the hippocampus expanded by 5 mm in 3-dimensions). In contrast to RTOG 0933, the maximum allowed point dose to normal brain was significantly lowered and restricted to 36.5 Gy. All patients were planned with volumetric modulated arc therapy (VMAT) technique using four arcs. Plans were optimized using Auto-Planning (AP) (Philips Radiation Oncology Systems) with one single AP template and optimization. All the constraints from the RTOG 0933 trial were achieved. A significant improvement for the maximal dose to 2% of the brain with a reduction of 4 Gy was achieved (33.5 Gy vs. RTOG 37.5 Gy) and the minimum hippocampus dose was reduced by 10% (8.1 Gy vs. RTOG 9 Gy). A steep dose gradient around the hippocampus was achieved with a mean dose of 27.3 Gy at a distance between 0.5 cm and 1 cm from the hippocampus. The effective working time to optimize a plan was kept below 6'. Automated treatment planning for HS WBRT was able to fulfil all the recommendations from the RTOG 0933 study while significantly improving dose homogeneity and decreasing unnecessary hot spot in the normal brain. With this approach, a standardization of plan quality was achieved and the effective time required for plan optimization was minimized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Hsin-Chen; Tan, Jun; Dolly, Steven
2015-02-15
Purpose: One of the most critical steps in radiation therapy treatment is accurate tumor and critical organ-at-risk (OAR) contouring. Both manual and automated contouring processes are prone to errors and to a large degree of inter- and intraobserver variability. These are often due to the limitations of imaging techniques in visualizing human anatomy as well as to inherent anatomical variability among individuals. Physicians/physicists have to reverify all the radiation therapy contours of every patient before using them for treatment planning, which is tedious, laborious, and still not an error-free process. In this study, the authors developed a general strategy basedmore » on novel geometric attribute distribution (GAD) models to automatically detect radiation therapy OAR contouring errors and facilitate the current clinical workflow. Methods: Considering the radiation therapy structures’ geometric attributes (centroid, volume, and shape), the spatial relationship of neighboring structures, as well as anatomical similarity of individual contours among patients, the authors established GAD models to characterize the interstructural centroid and volume variations, and the intrastructural shape variations of each individual structure. The GAD models are scalable and deformable, and constrained by their respective principal attribute variations calculated from training sets with verified OAR contours. A new iterative weighted GAD model-fitting algorithm was developed for contouring error detection. Receiver operating characteristic (ROC) analysis was employed in a unique way to optimize the model parameters to satisfy clinical requirements. A total of forty-four head-and-neck patient cases, each of which includes nine critical OAR contours, were utilized to demonstrate the proposed strategy. Twenty-nine out of these forty-four patient cases were utilized to train the inter- and intrastructural GAD models. These training data and the remaining fifteen testing data sets were separately employed to test the effectiveness of the proposed contouring error detection strategy. Results: An evaluation tool was implemented to illustrate how the proposed strategy automatically detects the radiation therapy contouring errors for a given patient and provides 3D graphical visualization of error detection results as well. The contouring error detection results were achieved with an average sensitivity of 0.954/0.906 and an average specificity of 0.901/0.909 on the centroid/volume related contouring errors of all the tested samples. As for the detection results on structural shape related contouring errors, an average sensitivity of 0.816 and an average specificity of 0.94 on all the tested samples were obtained. The promising results indicated the feasibility of the proposed strategy for the detection of contouring errors with low false detection rate. Conclusions: The proposed strategy can reliably identify contouring errors based upon inter- and intrastructural constraints derived from clinically approved contours. It holds great potential for improving the radiation therapy workflow. ROC and box plot analyses allow for analytically tuning of the system parameters to satisfy clinical requirements. Future work will focus on the improvement of strategy reliability by utilizing more training sets and additional geometric attribute constraints.« less
Recent advances in radiation cancer therapy
NASA Astrophysics Data System (ADS)
Ma, C.-M. Charlie
2007-03-01
This paper presents the recent advances in radiation therapy techniques for the treatment of cancer. Significant improvement has been made in imaging techniques such as CT, MRI, MRS, PET, ultrasound, etc. that have brought marked advances in tumor target and critical structure delineation for treatment planning and patient setup and target localization for accurate dose delivery in radiation therapy of cancer. Recent developments of novel treatment modalities including intensity-modulated x-ray therapy (IMXT), energy- and intensity modulated electron therapy (MERT) and intensity modulated proton therapy (IMPT) together with the use of advanced image guidance have enabled precise dose delivery for dose escalation and hypofractionation studies that may result in better local control and quality of life. Particle acceleration using laser-induced plasmas has great potential for new cost-effective radiation sources that may have a great impact on the management of cancer using radiation therapy.
Mendiratta, Prateek; Armstrong, Andrew J; George, Daniel J
2007-01-01
Prostate cancer is a common cause of death in men and remains incurable in the metastatic setting. In 2004, 2 landmark trials using docetaxel-based chemotherapy, TAX 327 and SWOG 99-16, showed a survival benefit for the first time in metastatic, hormone-refractory prostate cancer. Current research suggests that several distinct mechanisms of androgen-refractory disease may converge in patients with disease progression on androgen deprivation therapy. These findings have identified several potential targets for therapeutic intervention. Current standard and investigational treatment options for this disease are discussed, including chemotherapy and rapidly evolving therapies in phase II/III trials involving antiangiogenic therapies, signal transduction inhibitors, immunomodulatory agents, and nuclear receptor targets. In light of a growing array of treatment options and an increasingly chronic natural history, this review supports a multidisciplinary care approach to these patients, including medical oncologists, urologists, and radiation oncologists, to optimize survival and quality of life. PMID:17387372
Dutta, Pinaki R; Riaz, Nadeem; McBride, Sean; Morris, Luc G; Patel, Snehal; Ganly, Ian; Wong, Richard J; Palmer, Frank; Schöder, Heiko; Lee, Nancy
2016-04-01
The purpose of this study was for us to present our evaluation of the effectiveness of positron emission tomography (PET)/CT imaging in postoperative patients with oral cavity squamous cell carcinoma (SCC) before initiating adjuvant radiation therapy. Treatment planning PET/CT scans were obtained in 44 patients with oral cavity SCC receiving adjuvant radiation. We identified target areas harboring macroscopic disease requiring higher radiation doses or additional surgery. Fourteen PET/CT scans were abnormal. Thirteen patients underwent surgery and/or biopsy, increased radiation dose, and/or addition of chemotherapy. Eleven patients received higher radiation doses. Patients undergoing imaging >8 weeks were more likely to have abnormal results (p = .01). One-year distant metastases-free survival was significantly worse in patients with positive PET/CT scans (61.5% vs 92.7%; p = .01). The estimated positive predictive value (PPV) was 38% for postoperative PET/CT scanning. We demonstrated that 32% of patients have abnormal PET/CT scans resulting in management changes. Patients may benefit from postoperative PET/CT imaging to optimize adjuvant radiation treatment planning. © 2015 Wiley Periodicals, Inc. Head Neck 38: E1285-E1293, 2016. © 2015 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramroth, Johanna; Cutter, David J.; Darby, Sarah C.
Purpose: The optimum dose and fractionation in radiation therapy of curative intent for non-small cell lung cancer remains uncertain. We undertook a published data meta-analysis of randomized trials to examine whether radiation therapy regimens with higher time-corrected biologically equivalent doses resulted in longer survival, either when given alone or when given with chemotherapy. Methods and Materials: Eligible studies were randomized comparisons of 2 or more radiation therapy regimens, with other treatments identical. Median survival ratios were calculated for each comparison and pooled. Results: 3795 patients in 25 randomized comparisons of radiation therapy dose were studied. The median survival ratio, highermore » versus lower corrected dose, was 1.13 (95% confidence interval [CI] 1.04-1.22) when radiation therapy was given alone and 0.83 (95% CI 0.71-0.97) when it was given with concurrent chemotherapy (P for difference=.001). In comparisons of radiation therapy given alone, the survival benefit increased with increasing dose difference between randomized treatment arms (P for trend=.004). The benefit increased with increasing dose in the lower-dose arm (P for trend=.01) without reaching a level beyond which no further survival benefit was achieved. The survival benefit did not differ significantly between randomized comparisons where the higher-dose arm was hyperfractionated and those where it was not. There was heterogeneity in the median survival ratio by geographic region (P<.001), average age at randomization (P<.001), and year trial started (P for trend=.004), but not for proportion of patients with squamous cell carcinoma (P=.2). Conclusions: In trials with concurrent chemotherapy, higher radiation therapy doses resulted in poorer survival, possibly caused, at least in part, by high levels of toxicity. Where radiation therapy was given without chemotherapy, progressively higher radiation therapy doses resulted in progressively longer survival, and no upper dose level was found above which there was no further benefit. These findings support the consideration of further radiation therapy dose escalation trials, making use of modern treatment methods to reduce toxicity.« less
Taylor, Carolyn W; Wang, Zhe; Macaulay, Elizabeth; Jagsi, Reshma; Duane, Frances; Darby, Sarah C
2015-11-15
Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this "mean heart dose." In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28 countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose. Copyright © 2015 Elsevier Inc. All rights reserved.
Diwanji, Tejan P.; Mohindra, Pranshu; Vyfhuis, Melissa; Snider, James W.; Kalavagunta, Chaitanya; Mossahebi, Sina; Yu, Jen; Feigenberg, Steven
2017-01-01
The 21st century has seen several paradigm shifts in the treatment of non-small cell lung cancer (NSCLC) in early-stage inoperable disease, definitive locally advanced disease, and the postoperative setting. A key driver in improvement of local disease control has been the significant evolution of radiation therapy techniques in the last three decades, allowing for delivery of definitive radiation doses while limiting exposure of normal tissues. For patients with locally-advanced NSCLC, the advent of volumetric imaging techniques has allowed a shift from 2-dimensional approaches to 3-dimensional conformal radiation therapy (3DCRT). The next generation of 3DCRT, intensity-modulated radiation therapy and volumetric-modulated arc therapy (VMAT), have enabled even more conformal radiation delivery. Clinical evidence has shown that this can improve the quality of life for patients undergoing definitive management of lung cancer. In the early-stage setting, conventional fractionation led to poor outcomes. Evaluation of altered dose fractionation with the previously noted technology advances led to advent of stereotactic body radiation therapy (SBRT). This technique has dramatically improved local control and expanded treatment options for inoperable, early-stage patients. The recent development of proton therapy has opened new avenues for improving conformity and the therapeutic ratio. Evolution of newer proton therapy techniques, such as pencil-beam scanning (PBS), could improve tolerability and possibly allow reexamination of dose escalation. These new progresses, along with significant advances in systemic therapies, have improved survival for lung cancer patients across the spectrum of non-metastatic disease. They have also brought to light new challenges and avenues for further research and improvement. PMID:28529896
Whole breast radiation therapy
... 11, 2016. www.cancer.gov/types/breast/hp/breast-treatment-pdq . Accessed September 13, 2016. National Cancer Institute. Radiation therapy and you: support for people who have cancer. Cancer.gov Web site. www.cancer.gov/publications/patient-education/radiation-therapy-and-you . Accessed September 13, ...
Transsphenoidal microsurgery in the treatment of acromegaly and gigantism.
Arafah, B U; Brodkey, J S; Kaufman, B; Velasco, M; Manni, A; Pearson, O H
1980-03-01
Twenty-five patients with acromegaly and 3 patients with gigantism underwent transsphenoidal microsurgery in an attempt to remove the tumor and preserve normal pituitary function whenever possible. An adenoma was identified and removed in 27 of 28 patients. Evaluation 3--6 months postoperatively revealed a GH level less than 5 ng/ml in 29 patients, 5--10 ng/ml in 4 patients and 11--29 ng/ml in 4 other patients. Dynamics of GH secretion were normal in 11 patients who had normal pituitary function and are considered cured. Two patients with low or undetectable GH levels are also considered cured at the expense of being hypopituitary. Three of 7 patients with normal basal GH levels but abnormal dynamics of GH secretion relapsed within 1 yr. Eleven of the 13 patients considered cured did not have extrasellar extension, while 14 of the 15 patients not cured had extrasellar extension. Five patients who were not cured with surgery received radiation therapy. Three patients were treated with an ergot derivative, Lergotrile mesylate, after surgery and radiation therapy failed to normalize GH levels. Transsphenoidal microsurgery is an optimal form of therapy for patients with acromegaly or gigantism, especially those with no extrasellar extension. Dynamics of GH secretion are very useful in evaluating the completeness of adenoma removal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaidar-Person, Orit; Roach, Mack; Créhange, Gilles, E-mail: gcrehange@cgfl.fr
2013-07-15
Given the low α/β ratio of prostate cancer, prostate hypofractionation has been tested through numerous clinical studies. There is a growing body of literature suggesting that with high conformal radiation therapy and even with more sophisticated radiation techniques, such as high-dose-rate brachytherapy or image-guided intensity modulated radiation therapy, morbidity associated with shortening overall treatment time with higher doses per fraction remains low when compared with protracted conventional radiation therapy to the prostate only. In high-risk prostate cancer patients, there is accumulating evidence that either dose escalation to the prostate or hypofractionation may improve outcome. Nevertheless, selected patients who have amore » high risk of lymph node involvement may benefit from whole-pelvic radiation therapy (WPRT). Although combining WPRT with hypofractionated prostate radiation therapy is feasible, it remains investigational. By combining modern advances in radiation oncology (high-dose-rate prostate brachytherapy, intensity modulated radiation therapy with an improved image guidance for soft-tissue sparing), it is hypothesized that WPRT could take advantage of recent results from hypofractionation trials. Moreover, the results from hypofractionation trials raise questions as to whether hypofractionation to pelvic lymph nodes with a high risk of occult involvement might improve the outcomes in WPRT. Although investigational, this review discusses the challenging idea of WPRT in the context of hypofractionation for patients with high-risk prostate cancer.« less
Outcomes of Pediatric Low-grade Gliomas Treated With Radiation Therapy: A Single-institution Study
Raikar, Sunil S.; Halloran, Donna R.; Elliot, Michael; McHugh, Michele; Patel, Shaun; Gauvain, Karen M.
2014-01-01
Summary Radiation therapy is often considered the treatment of choice for low-grade gliomas. However, given the long-term effects of radiation on the developing brain, the appropriate use of radiation therapy in pediatric patients remains controversial. The purpose of this study was to evaluate progression-free survival (PFS) of pediatric low-grade glioma patients treated with radiation therapy. Data were obtained through a retrospective chart review of patients treated between 1991 and 2008 from a single tertiary care center in the midwest. The study population consisted of 17 patients, of whom 8 (47%) had tumor recurrence after radiation therapy. The median follow-up time was 8.2 years, with a range of 2.3 to 17.2 years. The median age at diagnosis was 5.4 years, and the median age at radiation therapy was 9.4 years. The 3- and the 10-year PFS were 69% ± 11.7% and 46% ± 13.3%, respectively. A significant difference in PFS was seen when comparing brainstem tumors with hypothalamic/optic pathway tumors (P = 0.019). Differences in PFS based on the age at diagnosis, the extent of initial surgery, and indication for radiation therapy were not significant. A larger multicenter study is needed to better assess PFS in these patients. PMID:24714505
Vano, Eliseo; Jimenez, Pablo; Ramirez, Raul; Zarzuela, Javier; Larcher, Ana Maria; Gallego, Eduardo; Gonzalez, Santiago; Del Rosario Perez, Maria
2018-03-01
During the International Conference on Radiation Protection in Medicine held in Bonn in 2012, several areas for improvement were identified, including specific actions related with justification, optimization, role of manufacturers, radiation protection education and training, strategic research, data collection on medical and occupational exposures, prevention of incidents and accidents, radiation safety culture, risk-benefit dialogue and implementation of the radiation safety standards. The outcomes of the Bonn Conference were summarized in the so-called 'Bonn Call for Action', identifying 10 priority actions to enhance RP in medicine. Trying to analyse the progress in the implementation of this 'Call for Action' in the Ibero-American region, several international organizations organized the 'Ibero-American Conference on Radiation Protection in Medicine' (Conferencia Iberoamericana sobre Protección Radiológica en Medicina, CIPRaM) held in Madrid, in October 2016. CIPRaM was structured in eight thematic sessions dealing with: diagnostic and dental radiology, image guided interventional radiology, nuclear medicine, radiation therapy, health authorities and radiation protection regulators, professional associations of technologists and nurses, professional associations of medical physicists and radiation protection experts, and universities and researchers in radiation protection in medicine. This paper summarizes the main results of that Conference based on the consensus achieved about main problems, solutions, and indicators to evaluate the implementation of the proposed solutions.
Chang, Amy T Y; Hung, Albert W M; Cheung, Fion W K; Lee, Michael C H; Chan, Oscar S H; Philips, Helen; Cheng, Yung-Tang; Ng, Wai-Tong
2016-07-01
Intensity modulated radiation therapy (IMRT) is widely used to achieve a highly conformal dose and improve treatment outcome. However, plan quality and planning time are institute and planner dependent, and no standardized tool exists to recognize an optimal plan. RapidPlan, a knowledge-based algorithm, can generate constraints to assist optimization and produce high-quality IMRT plans. This report evaluated the quality and efficiency of using RapidPlan in nasopharyngeal carcinoma (NPC) IMRT planning. RapidPlan was configured using 79 radical IMRT plans for NPC; 20 consecutive NPC patients indicated for radical radiation therapy between October 2014 and May 2015 were then recruited to assess its performance. The ability of RapidPlan to produce acceptable plans was evaluated. For plans that could not achieve clinical acceptance, manual touch-up was performed. The IMRT plans produced without RapidPlan (manual plans) and with RapidPlan (RP-2 plans, including those with manual touch-up) were compared in terms of dosimetric quality and planning efficiency. RapidPlan by itself could produce clinically acceptable plans for 9 of the 20 patients; manual touch-up increased the number of acceptable plans (RP-2 plans) to 19. The target dose coverage and conformity were very similar. No difference was found in the maximum dose to the brainstem and optic chiasm. RP-2 plans delivered a higher maximum dose to the spinal cord (46.4 Gy vs 43.9 Gy, P=.002) but a lower dose to the parotid (mean dose to right parotid, 37.3 Gy vs 45.4 Gy; left, 34.4 Gy vs 43.1 Gy; P<.001) and the right cochlea (mean dose, 48.6 Gy vs 52.6 Gy; P=.02). The total planning time for RP-2 plans was significantly less than that for manual plans (64 minutes vs 295 minutes, P<.001). This study shows that RapidPlan can significantly improve planning efficiency and produce quality IMRT plans for NPC patients. Copyright © 2016 Elsevier Inc. All rights reserved.
Xu, Yingjie; Yan, Hui; Hu, Zhihui; Ma, Pan; Men, Kuo; Huang, Peng; Ren, Wenting; Dai, Jianrong; Li, Yexiong
2017-01-01
Given the design of the Helical TomoTherapy device, the patient's central axis is routinely aligned with the machine's rotational axis to prevent the patient's body from colliding with the machine walls. However, for treatment of tumors located away from the patient's central axis, this position may not be optimal as the adequate radiation dose may not reach the affected site. Our study aimed to investigate the influence of tumor location on dose quality and delivery efficiency of tomotherapy plans. A phantom and 15 patients were selected for this study. Two plans, A and B, were implemented for each case. In plan A, the patient's central axis was aligned with the machine's rotational axis, whereas in plan B, the center of the planning target volume (PTV) was aligned with the machine's rotational axis. Both plans were optimized with the same planning parameters, and the dose quality of the plans was evaluated using dosimetrics. The delivery efficiency was determined from delivery time and monitor units (MUs). A paired t-test or nonparametric Wilcoxon signed-rank test was performed for statistical comparison. In the phantom study, the median delivery times were 358 and 336 seconds for plans A and B, respectively, and this difference was significant (p = 0.005). In the patient study, the median delivery times were 348 and 317 seconds for plans A and B, respectively, and this difference was also significant (p = 0.001). The dose qualities of both plans for each patient were nearly identical. No significant differences were found in the conformal index, heterogeneity index, and mean dose delivered to normal tissue between the plans. Both phantom and patient studies showed that for normal-sized patients, the delivery time reduced as the distance between the PTV and the patient's central axis increased when the PTV center was aligned with the machine axis. In conclusion, aligning the PTV center with the machine's rotational axis by shifting the patient during tomotherapy reduces the delivery time without compromising the dose quality of intensity-modulated radiation therapy. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Expanding the use of real-time electromagnetic tracking in radiation oncology.
Shah, Amish P; Kupelian, Patrick A; Willoughby, Twyla R; Meeks, Sanford L
2011-11-15
In the past 10 years, techniques to improve radiotherapy delivery, such as intensity-modulated radiation therapy (IMRT), image-guided radiation therapy (IGRT) for both inter- and intrafraction tumor localization, and hypofractionated delivery techniques such as stereotactic body radiation therapy (SBRT), have evolved tremendously. This review article focuses on only one part of that evolution, electromagnetic tracking in radiation therapy. Electromagnetic tracking is still a growing technology in radiation oncology and, as such, the clinical applications are limited, the expense is high, and the reimbursement is insufficient to cover these costs. At the same time, current experience with electromagnetic tracking applied to various clinical tumor sites indicates that the potential benefits of electromagnetic tracking could be significant for patients receiving radiation therapy. Daily use of these tracking systems is minimally invasive and delivers no additional ionizing radiation to the patient, and these systems can provide explicit tumor motion data. Although there are a number of technical and fiscal issues that need to be addressed, electromagnetic tracking systems are expected to play a continued role in improving the precision of radiation delivery.
Expanding the use of real‐time electromagnetic tracking in radiation oncology
Kupelian, Patrick A.; Willoughby, Twyla R.; Meeks, Sanford L.
2011-01-01
In the past 10 years, techniques to improve radiotherapy delivery, such as intensity‐modulated radiation therapy (IMRT), image‐guided radiation therapy (IGRT) for both inter‐ and intrafraction tumor localization, and hypofractionated delivery techniques such as stereotactic body radiation therapy (SBRT), have evolved tremendously. This review article focuses on only one part of that evolution, electromagnetic tracking in radiation therapy. Electromagnetic tracking is still a growing technology in radiation oncology and, as such, the clinical applications are limited, the expense is high, and the reimbursement is insufficient to cover these costs. At the same time, current experience with electromagnetic tracking applied to various clinical tumor sites indicates that the potential benefits of electromagnetic tracking could be significant for patients receiving radiation therapy. Daily use of these tracking systems is minimally invasive and delivers no additional ionizing radiation to the patient, and these systems can provide explicit tumor motion data. Although there are a number of technical and fiscal issues that need to be addressed, electromagnetic tracking systems are expected to play a continued role in improving the precision of radiation delivery. PACS number: 87.63.‐d PMID:22089017
Kulasekere, Ravi; Moran, Jean M.; Fraass, Benedick A.; Roberson, Peter L.
2006-01-01
A single calibration film method was evaluated for use with intensity‐modulated radiation therapy film quality assurance measurements. The single‐film method has the potential advantages of exposure simplicity, less media consumption, and improved processor quality control. Potential disadvantages include cross contamination of film exposure, implementation effort to document delivered dose, and added complication of film response analysis. Film response differences were measured between standard and single‐film calibration methods. Additional measurements were performed to help trace causes for the observed discrepancies. Kodak X‐OmatV (XV) film was found to have greater response variability than extended dose range (EDR) film. We found it advisable for XV film to relate the film response calibration for the single‐film method to a user‐defined optimal calibration geometry. Using a single calibration film exposed at the time of experiment, the total uncertainty of film response was estimated to be <2% (1%) for XV (EDR) film at 50 (100) cGy and higher, respectively. PACS numbers: 87.53.‐j, 87.53.Dq PMID:17533325
21 CFR 1020.32 - Fluoroscopic equipment.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... Radiation therapy simulation systems shall be exempt from this requirement provided the systems are intended... 10, 2006, other than radiation therapy simulation systems, the following applies: (A) Neither the... fluoroscopic equipment manufactured on or after June 10, 2006, other than radiation therapy simulation systems...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slagsvold, Jens Erik, E-mail: Jens.Erik.Slagsvold@stolav.no; Viset, Trond; Wibe, Arne
Purpose: To investigate long-term changes in the rectal mucosa after curative external beam radiation therapy in the treatment of prostate cancer. Methods and Materials: In the Scandinavian Prostate Cancer Group 7 trial, 880 men with locally advanced prostate cancer were randomized to hormonal therapy alone versus hormonal therapy plus radiation therapy to 70 Gy. A subcohort from this trial being randomized at our center (n=178) was invited to a study on late anorectal side effects during 2003-2005, approximately 5 years after treatment, including measuring health-reported quality of life and physician-assessed toxicity score by the Late Effects Normal Tissue Task Force/Subjective, Objective, Management, Analyticmore » (LENT/SOMA) and European Organization for Research and Treatment of Cancer/Radiation Therapy Oncology Group score. Sixty-seven patients had a rectal mucosa biopsy. Sixty-four biopsies were included in the final analysis, of which 33 patients were randomized to hormonal treatment and 31 to hormonal treatment plus radiation therapy. The presence of fibrosis, number of capillaries, and lymphocyte infiltration was then evaluated by light microscopy. Results: The group receiving radiation therapy had significantly higher LENT/SOMA and function/bother scale scores than the group that only received hormonal treatment, but there was no significant difference in the presence of fibrosis, ectasia, number of capillaries in the lamina propria, or lymphocyte infiltration between the groups. Conclusion: Radiation therapy to 70 Gy to the prostate does not induce long-term microscopic mucosal changes in the rectum 5 years after treatment. This is in contrast to the general assumption that structural changes, including fibrosis, seen after radiation therapy include the mucosa. We speculate that the main late effects of radiation therapy on the structure of the rectum are located in the deeper layers of the rectal wall than the mucosa.« less
Goodman, Karyn A; Patton, Caroline E; Fisher, George A; Hoffe, Sarah E; Haddock, Michael G; Parikh, Parag J; Kim, John; Baxter, Nancy N; Czito, Brian G; Hong, Theodore S; Herman, Joseph M; Crane, Christopher H; Hoffman, Karen E
2016-01-01
To summarize results of a Clinical Practice Statement on radiation therapy for stage II-III rectal cancer, which addressed appropriate customization of (neo)adjuvant radiation therapy and use of non-surgical therapy for patients who are inoperable or refuse abdominoperineal resection. The RAND/University of California, Los Angeles, Appropriateness Method was applied to combine current evidence with multidisciplinary expert opinion. A systematic literature review was conducted and used by the expert panel to rate appropriateness of radiation therapy options for different clinical scenarios. Treatments were categorized by median rating as Appropriate, May Be Appropriate, or Rarely Appropriate. In the neoadjuvant setting, chemoradiation was rated Appropriate and the ratings indicated short-course radiation therapy, chemotherapy alone, and no neoadjuvant therapy are potential options in selected patients. However, neoadjuvant endorectal brachytherapy was rated Rarely Appropriate. For adjuvant therapy, chemoradiation (plus ≥4 months of chemotherapy) was rated Appropriate and chemotherapy alone May Be Appropriate for most scenarios. For medically inoperable patients, definitive external beam radiation therapy and chemotherapy alone were rated May Be Appropriate, whereas endorectal brachytherapy and chemoradiation plus endorectal brachytherapy were possible approaches for some scenarios. The last option, definitive chemoradiation, was rated Appropriate to May Be Appropriate based on performance status. Finally, for patients with low-lying tumors refusing abdominoperineal resection, definitive chemoradiation alone, chemoradiation plus endorectal brachytherapy, and chemoradiation plus external beam radiation therapy were all rated Appropriate. This Clinical Practice Statement demonstrated the central role of radiation therapy in stage II-III rectal cancer management and evaluated ways to better individualize its use in the neoadjuvant, adjuvant, and definitive settings. Ongoing trials may clarify areas of continuing uncertainty and allow further customization. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Bernstein, Jonine L; Langholz, Bryan; Haile, Robert W; Bernstein, Leslie; Thomas, Duncan C; Stovall, Marilyn; Malone, Kathleen E; Lynch, Charles F; Olsen, Jørgen H; Anton-Culver, Hoda; Shore, Roy E; Boice, John D; Berkowitz, Gertrud S; Gatti, Richard A; Teitelbaum, Susan L; Smith, Susan A; Rosenstein, Barry S; Børresen-Dale, Anne-Lise; Concannon, Patrick; Thompson, W Douglas
2004-01-01
Introduction Deficiencies in cellular responses to DNA damage can predispose to cancer. Ionizing radiation can cause cluster damage and double-strand breaks (DSBs) that pose problems for cellular repair processes. Three genes (ATM, BRCA1, and BRCA2) encode products that are essential for the normal cellular response to DSBs, but predispose to breast cancer when mutated. Design To examine the joint roles of radiation exposure and genetic susceptibility in the etiology of breast cancer, we designed a case-control study nested within five population-based cancer registries. We hypothesized that a woman carrying a mutant allele in one of these genes is more susceptible to radiation-induced breast cancer than is a non-carrier. In our study, 700 women with asynchronous bilateral breast cancer were individually matched to 1400 controls with unilateral breast cancer on date and age at diagnosis of the first breast cancer, race, and registry region, and counter-matched on radiation therapy. Each triplet comprised two women who received radiation therapy and one woman who did not. Radiation absorbed dose to the contralateral breast after initial treatment was estimated with a comprehensive dose reconstruction approach that included experimental measurements in anthropomorphic and water phantoms applying patient treatment parameters. Blood samples were collected from all participants for genetic analyses. Conclusions Our study design improves the potential for detecting gene–environment interactions for diseases when both gene mutations and the environmental exposures of interest are rare in the general population. This is particularly applicable to the study of bilateral breast cancer because both radiation dose and genetic susceptibility have important etiologic roles, possibly by interactive mechanisms. By using counter-matching, we optimized the informativeness of the collected dosimetry data by increasing the variability of radiation dose within the case–control sets and enhanced our ability to detect radiation–genotype interactions. PMID:15084244
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Jieming; Atwood, Todd; Eyben, Rie von
2015-08-01
Purpose: To develop planning and delivery capabilities for linear accelerator–based nonisocentric trajectory modulated arc therapy (TMAT) and to evaluate the benefit of TMAT for accelerated partial breast irradiation (APBI) with the patient in prone position. Methods and Materials: An optimization algorithm for volumetrically modulated arc therapy (VMAT) was generalized to allow for user-defined nonisocentric TMAT trajectories combining couch rotations and translations. After optimization, XML scripts were automatically generated to program and subsequently deliver the TMAT plans. For 10 breast patients in the prone position, TMAT and 6-field noncoplanar intensity modulated radiation therapy (IMRT) plans were generated under equivalent objectives andmore » constraints. These plans were compared with regard to whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose. Results: For TMAT APBI, nonisocentric collision-free horizontal arcs with large angular span (251.5 ± 7.9°) were optimized and delivered with delivery time of ∼4.5 minutes. Percentage changes of whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose for TMAT relative to IMRT were −10.81% ± 6.91%, −27.81% ± 7.39%, −14.82% ± 9.67%, and 39.40% ± 10.53% (P≤.01). Conclusions: This is a first demonstration of end-to-end planning and delivery implementation of a fully dynamic APBI TMAT. Compared with IMRT, TMAT resulted in marked reduction of the breast tissue volume irradiated at high doses.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Huiqiao; Yang, Yi; Tang, Xiangyang
2015-06-15
Purpose: Optimization-based reconstruction has been proposed and investigated for reconstructing CT images from sparse views, as such the radiation dose can be substantially reduced while maintaining acceptable image quality. The investigation has so far focused on reconstruction from evenly distributed sparse views. Recognizing the clinical situations wherein only unevenly sparse views are available, e.g., image guided radiation therapy, CT perfusion and multi-cycle cardiovascular imaging, we investigate the performance of optimization-based image reconstruction from unevenly sparse projection views in this work. Methods: The investigation is carried out using the FORBILD and an anthropomorphic head phantoms. In the study, 82 views, whichmore » are evenly sorted out from a full (360°) axial CT scan consisting of 984 views, form sub-scan I. Another 82 views are sorted out in a similar manner to form sub-scan II. As such, a CT scan with sparse (164) views at 1:6 ratio are formed. By shifting the two sub-scans relatively in view angulation, a CT scan with unevenly distributed sparse (164) views at 1:6 ratio are formed. An optimization-based method is implemented to reconstruct images from the unevenly distributed views. By taking the FBP reconstruction from the full scan (984 views) as the reference, the root mean square (RMS) between the reference and the optimization-based reconstruction is used to evaluate the performance quantitatively. Results: In visual inspection, the optimization-based method outperforms the FBP substantially in the reconstruction from unevenly distributed, which are quantitatively verified by the RMS gauged globally and in ROIs in both the FORBILD and anthropomorphic head phantoms. The RMS increases with increasing severity in the uneven angular distribution, especially in the case of anthropomorphic head phantom. Conclusion: The optimization-based image reconstruction can save radiation dose up to 12-fold while providing acceptable image quality for advanced clinical applications wherein only unevenly distributed sparse views are available. Research Grants: W81XWH-12-1-0138 (DoD), Sinovision Technologies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapur, A.
The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequentialmore » events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.« less
Risk of secondary malignancies after radiation therapy for breast cancer: Comprehensive results.
Burt, Lindsay M; Ying, Jian; Poppe, Matthew M; Suneja, Gita; Gaffney, David K
2017-10-01
To assess risks of secondary malignancies in breast cancer patients who received radiation therapy compared to patients who did not. The SEER database was used to identify females with a primary diagnosis of breast cancer as their first malignancy, during 1973-2008. We excluded patients with metastatic disease, age <18 years, no definitive surgical intervention, ipsilateral breast cancer recurrence, or who developed a secondary malignancy within 1 year of diagnosis. Standardized incidence ratios and absolute excess risk were calculated using SEER*Stat, version 8.2.1 and SAS, version 9.4. There were 374,993 patients meeting the inclusion criteria, with 154,697 who received radiation therapy. With a median follow-up of 8.9 years, 13% of patients (49,867) developed a secondary malignancy. The rate of secondary malignancies was significantly greater than the endemic rate in breast cancer patients treated without radiation therapy, (O/E 1.2, 95% CI 1.19-1.22) and with radiation therapy (O/E 1.33, 95% CI 1.31-1.35). Approximately 3.4% of secondary malignancies were attributable to radiation therapy. The increased risk of secondary malignancies in breast cancer patients treated with radiation therapy compared to those without was significant regardless of age at breast cancer diagnosis (p < 0.01) and more pronounced with longer latency periods. There was an increased risk of secondary malignancies for breast cancer patients both with and without radiation therapy compared to the general population. There was an increased risk in specific sites for patients treated with radiation therapy. This risk was most evident in young patients and who had longer latency periods. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghorbanzadeh-Moghaddam, Amir; Gholamrezaei, Ali, E-mail: Gholamrezaei@med.mui.ac.ir; Poursina Hakim Research Institution, Isfahan
Purpose: Radiation-induced injury to normal tissues is a common complication of radiation therapy in cancer patients. Considering the role of vitamin D in mucosal barrier hemostasis and inflammatory responses, we investigated whether vitamin D deficiency is associated with the severity of radiation-induced acute proctitis in cancer patients. Methods and Materials: This prospective observational study was conducted in cancer patients referred for pelvic radiation therapy. Serum concentration of 25-hydroxyvitamin D was measured before radiation therapy. Vitamin D deficiency was defined as 25-hydroxyvitamin D concentrations of <35 nmol/L and <40 nmol/L in male and female patients, respectively, based on available normative data.more » Acute proctitis was assessed after 5 weeks of radiation therapy (total received radiation dose of 50 Gy) and graded from 0 to 4 using Radiation Therapy Oncology Group (RTOG) criteria. Results: Ninety-eight patients (57.1% male) with a mean age of 62.8 ± 9.1 years were studied. Vitamin D deficiency was found in 57 patients (58.1%). Symptoms of acute proctitis occurred in 72 patients (73.4%) after radiation therapy. RTOG grade was significantly higher in patients with vitamin D deficiency than in normal cases (median [interquartile range] of 2 [0.5-3] vs 1 [0-2], P=.037). Vitamin D deficiency was associated with RTOG grade of ≥2, independent of possible confounding factors; odds ratio (95% confidence interval) = 3.07 (1.27-7.50), P=.013. Conclusions: Vitamin D deficiency is associated with increased severity of radiation-induced acute proctitis. Investigating the underlying mechanisms of this association and evaluating the effectiveness of vitamin D therapy in preventing radiation-induced acute proctitis is warranted.« less
Recent Advances in Cancer Therapy Based on Dual Mode Gold Nanoparticles
Spyratou, Ellas; Makropoulou, Mersini; Sihver, Lembit
2017-01-01
Many tumor-targeted strategies have been used worldwide to limit the side effects and improve the effectiveness of therapies, such as chemotherapy, radiotherapy (RT), etc. Biophotonic therapy modalities comprise very promising alternative techniques for cancer treatment with minimal invasiveness and side-effects. These modalities use light e.g., laser irradiation in an extracorporeal or intravenous mode to activate photosensitizer agents with selectivity in the target tissue. Photothermal therapy (PTT) is a minimally invasive technique for cancer treatment which uses laser-activated photoabsorbers to convert photon energy into heat sufficient to induce cells destruction via apoptosis, necroptosis and/or necrosis. During the last decade, PTT has attracted an increased interest since the therapy can be combined with customized functionalized nanoparticles (NPs). Recent advances in nanotechnology have given rise to generation of various types of NPs, like gold NPs (AuNPs), designed to act both as radiosensitizers and photothermal sensitizing agents due to their unique optical and electrical properties i.e., functioning in dual mode. Functionalized AuNPS can be employed in combination with non-ionizing and ionizing radiation to significantly improve the efficacy of cancer treatment while at the same time sparing normal tissues. Here, we first provide an overview of the use of NPs for cancer therapy. Then we review many recent advances on the use of gold NPs in PTT, RT and PTT/RT based on different types of AuNPs, irradiation conditions and protocols. We refer to the interaction mechanisms of AuNPs with cancer cells via the effects of non-ionizing and ionizing radiations and we provide recent existing experimental data as a baseline for the design of optimized protocols in PTT, RT and PTT/RT combined treatment. PMID:29257070
Follicular Lymphoma in the United States: First Report of the National LymphoCare Study
Friedberg, Jonathan W.; Taylor, Michael D.; Cerhan, James R.; Flowers, Christopher R.; Dillon, Hildy; Farber, Charles M.; Rogers, Eric S.; Hainsworth, John D.; Wong, Elaine K.; Vose, Julie M.; Zelenetz, Andrew D.; Link, Brian K.
2009-01-01
Purpose Optimal therapy of follicular lymphoma (FL) is not defined. We analyzed a large prospective cohort study to identify current demographics and patterns of care of FL in the United States. Patients and Methods The National LymphoCare Study is a multicenter, longitudinal, observational study designed to collect information on treatment regimens and outcomes for patients with newly diagnosed FL in the United States. Patients were enrolled between 2004 and 2007. There is no study-specific prescribed treatment regimen or intervention. Results Two thousand seven hundred twenty-eight subjects were enrolled at 265 sites, including the 80% of patients enrolled from nonacademic sites. Using the Follicular Lymphoma International Prognostic Index (FLIPI), three distinct groups independent of histologic grade could be defined. Initial therapeutic strategy was: observation, 17.7%; rituximab monotherapy, 13.9%; clinical trial 6.1%; radiation therapy, 5.6%; chemotherapy only, 3.2%; chemotherapy plus rituximab, 51.9%. Chemotherapy plus rituximab regimens were: rituximab plus cyclophosphamide, doxorubicin, vincristine, prednisone, 55.0%; rituximab plus cyclophosphamide, vincristine, and prednisone, 23.1%; rituximab plus fludarabine based, 15.5%; other, 6.4%. The choice to initiate therapy rather than observe was associated with age, FLIPI, stage, and grade (P < .01). Significant differences in treatment (P < .01) across regions of the United States were noted. Contrary to practice guidelines, treatment of stage I FL frequently omits radiation therapy. Conclusion Widely disparate therapeutic approaches are utilized for FL. Initial therapy is deferred in a small subset of patients. There is no single standard of care for the treatment of de novo FL, although antibody use is ubiquitous when therapy is initiated. These disparate approaches to the initial care of patients with FL render a heterogeneous group of patients at relapse. PMID:19204203
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huddart, Robert A., E-mail: robert.huddart@icr.ac.uk; Hall, Emma; Hussain, Syed A.
2013-10-01
Purpose: To test whether reducing radiation dose to uninvolved bladder while maintaining dose to the tumor would reduce side effects without impairing local control in the treatment of muscle-invasive bladder cancer. Methods and Materials: In this phase III multicenter trial, 219 patients were randomized to standard whole-bladder radiation therapy (sRT) or reduced high-dose volume radiation therapy (RHDVRT) that aimed to deliver full radiation dose to the tumor and 80% of maximum dose to the uninvolved bladder. Participants were also randomly assigned to receive radiation therapy alone or radiation therapy plus chemotherapy in a partial 2 × 2 factorial design. Themore » primary endpoints for the radiation therapy volume comparison were late toxicity and time to locoregional recurrence (with a noninferiority margin of 10% at 2 years). Results: Overall incidence of late toxicity was less than predicted, with a cumulative 2-year Radiation Therapy Oncology Group grade 3/4 toxicity rate of 13% (95% confidence interval 8%, 20%) and no statistically significant differences between groups. The difference in 2-year locoregional recurrence free rate (RHDVRT − sRT) was 6.4% (95% confidence interval −7.3%, 16.8%) under an intention to treat analysis and 2.6% (−12.8%, 14.6%) in the “per-protocol” population. Conclusions: In this study RHDVRT did not result in a statistically significant reduction in late side effects compared with sRT, and noninferiority of locoregional control could not be concluded formally. However, overall low rates of clinically significant toxicity combined with low rates of invasive bladder cancer relapse confirm that (chemo)radiation therapy is a valid option for the treatment of muscle-invasive bladder cancer.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dolz, J., E-mail: jose.dolz.upv@gmail.com; Kirişli, H. A.; Massoptier, L.
2016-05-15
Purpose: Accurate delineation of organs at risk (OARs) on computed tomography (CT) image is required for radiation treatment planning (RTP). Manual delineation of OARs being time consuming and prone to high interobserver variability, many (semi-) automatic methods have been proposed. However, most of them are specific to a particular OAR. Here, an interactive computer-assisted system able to segment various OARs required for thoracic radiation therapy is introduced. Methods: Segmentation information (foreground and background seeds) is interactively added by the user in any of the three main orthogonal views of the CT volume and is subsequently propagated within the whole volume.more » The proposed method is based on the combination of watershed transformation and graph-cuts algorithm, which is used as a powerful optimization technique to minimize the energy function. The OARs considered for thoracic radiation therapy are the lungs, spinal cord, trachea, proximal bronchus tree, heart, and esophagus. The method was evaluated on multivendor CT datasets of 30 patients. Two radiation oncologists participated in the study and manual delineations from the original RTP were used as ground truth for evaluation. Results: Delineation of the OARs obtained with the minimally interactive approach was approved to be usable for RTP in nearly 90% of the cases, excluding the esophagus, which segmentation was mostly rejected, thus leading to a gain of time ranging from 50% to 80% in RTP. Considering exclusively accepted cases, overall OARs, a Dice similarity coefficient higher than 0.7 and a Hausdorff distance below 10 mm with respect to the ground truth were achieved. In addition, the interobserver analysis did not highlight any statistically significant difference, at the exception of the segmentation of the heart, in terms of Hausdorff distance and volume difference. Conclusions: An interactive, accurate, fast, and easy-to-use computer-assisted system able to segment various OARs required for thoracic radiation therapy has been presented and clinically evaluated. The introduction of the proposed system in clinical routine may offer valuable new option to radiation oncologists in performing RTP.« less
A portable thermal imaging device as a feedback system for breast cancer treatment
NASA Astrophysics Data System (ADS)
Hoffer, Oshrit A.; Ben-David, Merav A.; Katz, Eyal; Sholomov, Meny; Kelson, Itzhak; Gannot, Israel
2018-02-01
Breast cancer is the most frequently diagnosed cancer among women in the Western world. Currently, no imaging technique assesses tumor heat generation and vasculature changes during radiotherapy in viable tumor and as adjuvant therapy. Thermography is a non-ionizing, non-invasive, portable and low-cost imaging modality. The purpose of this study was to investigate the use of thermography in cancer treatment monitoring for feedback purposes. Six stage-IV breast cancer patients with viable breast tumor and 8 patients (9 breasts) who underwent tumor resection were monitored by a thermal camera prior to radiotherapy sessions over several weeks of radiation treatment. The thermal changes over the treated breast were calculated and analyzed for comparison with healthy surrounded breast tissue or contralateral breast. A model of a breast with a tumor was created. The COMSOL FEM software was used to carry out the analysis. The effects of tumor metabolism and breast tissue perfusion on the temperature difference were analyzed. All patients with active tumors exhibited drops in maximal temperature of the tumor during radiation therapy. The patients who underwent radiotherapy as adjuvant treatment exhibited a rise in maximal temperature over the treated breast in correlation with skin erythema during radiation. This difference between the groups was statistically significant (P=0.001). The simulated human breast cancer models analysis showed that tumor aggressiveness reduction causes decrease in the tumor temperature. Inflammation causes vasodilatation and increases tissue perfusion, resulted in an increase in breast tissue temperature. A correlation was demonstrated between the clinical outcome and the simulation. We report a method for monitoring cancer response to radiation therapy, which measures the physiological response along with clinical response. These anticipatory efficacy evaluations of radiotherapy during treatment may further promote changes in treatment regimen, either radiation associated or combination as in chemo-radiation protocols. The probable treatment delivery changes may incorporate the total dose delivery, fraction dose and intensity as well as adding chemotherapy for non-responding tumors during radiotherapy. All the above possibilities will contribute to the advances of individualized, personalized cancer treatment for optimal treatment effectiveness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Allen M., E-mail: allen.chen@ucdmc.ucdavis.ed; Chen, Leon M.; Vaughan, Andrew
Purpose: To evaluate the effect of continued cigarette smoking among patients undergoing radiation therapy for head-and-neck cancer by comparing the clinical outcomes among active smokers and quitters. Methods and Materials: A review of medical records identified 101 patients with newly diagnosed squamous cell carcinoma of the head and neck who continued to smoke during radiation therapy. Each active smoker was matched to a control patient who had quit smoking before initiation of radiation therapy. Matching was based on tobacco history (pack-years), primary site, age, sex, Karnofsky Performance Status, disease stage, radiation dose, chemotherapy use, year of treatment, and whether surgicalmore » resection was performed. Outcomes were compared by use of Kaplan-Meier analysis. Normal tissue effects were graded according to the Radiation Therapy Oncology Group/European Organization for the Treatment of Cancer toxicity criteria. Results: With a median follow-up of 49 months, active smokers had significantly inferior 5-year overall survival (23% vs. 55%), locoregional control (58% vs. 69%), and disease-free survival (42% vs. 65%) compared with the former smokers who had quit before radiation therapy (p < 0.05 for all). These differences remained statistically significant when patients treated by postoperative or definitive radiation therapy were analyzed separately. The incidence of Grade 3 or greater late complications was also significantly increased among active smokers compared with former smokers (49% vs. 31%, p = 0.01). Conclusions: Tobacco smoking during radiation therapy for head-and-neck cancer is associated with unfavorable outcomes. Further studies analyzing the biologic and molecular reasons underlying these differences are planned.« less
Crittenden, Marka R.; Savage, Talicia; Cottam, Benjamin; Bahjat, Keith S.; Redmond, William L.; Bambina, Shelly; Kasiewicz, Melissa; Newell, Pippa; Jackson, Andrew M.; Gough, Michael J.
2013-01-01
Expansion of myeloid-lineage leukocytes in tumor-bearing mice has been proposed as a cause of systemic immunosuppression. We demonstrate that radiation therapy of tumors leads to a decline in myeloid cell numbers in the blood and a decrease in spleen size. The frequency of myeloid cells does not decline to the level seen in tumor-free mice: we demonstrate that metastatic disease can prevent myeloid cell numbers from returning to baseline, and that tumor recurrence from residual disease correlates with re-expansion of myeloid lineage cells. Radiation therapy results in increased proliferation of T cells in the spleen and while T cell responses to foreign antigens are not altered by tumor burden or myeloid cell expansion, responses to tumor-associated antigens are increased after radiation therapy. These data demonstrate that myeloid cell numbers are directly linked to primary tumor burden, that this population contracts following radiation therapy, and that radiation therapy may open a therapeutic window for immunotherapy of residual disease. PMID:23936036
Radiation therapy is a type of cancer treatment that uses high doses of radiation to kill cancer cells and shrink tumors. Learn about the types of radiation, why side effects happen, which ones you might have, and more.
Lee, Yu-San; Kao, Yu-Hsiu
2016-08-01
The skin reaction rate is 60-95% in cancer patients that receive radiation therapy. This therapy is likely to cause physical and mental discomfort and prolong treatment for patients. The current emphasis on lectures rather than practice to help nurses learn proper skin care practices likely imposes difficulties for nurses to handle various clinical situations. To investigate the learning effectiveness of a simulated radiation therapy skin care workshop for nurses. A total of 34 nurses at a hospital in one health system in northern Taiwan who had never used radiation therapy to provide care to patients were enrolled in this quasi-experimental study. A single group pretest, posttest and post-posttest (6 weeks after intervention) approach was used. At the simulated radiation therapy skin care workshop, we used teaching strategies including Ausubel's direct instruction teaching method and practice on simulated wounds on pig skins. Outcomes were evaluated using "the questionnaire of radiation therapy skin care" and "direct observation of procedural skills checklist". The results from the simulated radiation therapy skin care workshop were analyzed using GEE (generalized estimating equation). The post-posttest and posttest scores increased significantly; knowledge mean score 3.14 (< .001) vs 2.64 (< .001), attitude mean score 2.06 (p < .05) vs 2.24 (p < .001), and skill mean score 2.79 (p < .001) vs 1.68 (p < .001). The simulated radiation therapy skin care workshop demonstrated significant and positive effects on learning outcomes. Therefore, we recommend incorporating this workshop into clinical nursing education and training strategies in the future.
Oh, Se An; Yea, Ji Woon; Kim, Sung Kyu
2016-01-01
Respiratory-gated radiation therapy (RGRT) is used to minimize the radiation dose to normal tissue in lung-cancer patients. Although determining the gating window in the respiratory phase of patients is important in RGRT, it is not easy. Our aim was to determine the optimal gating window when using a visible guiding system for RGRT. Between April and October 2014, the breathing signals of 23 lung-cancer patients were recorded with a real-time position management (RPM) respiratory gating system (Varian, USA). We performed statistical analysis with breathing signals to find the optimal gating window for guided breathing in RGRT. When we compared breathing signals before and after the breathing training, 19 of the 23 patients showed statistically significant differences (p < 0.05). The standard deviation of the respiration signals after breathing training was lowest for phases of 30%-70%. The results showed that the optimal gating window in RGRT is 40% (30%-70%) with respect to repeatability for breathing after respiration training with the visible guiding system. RGRT was performed with the RPM system to confirm the usefulness of the visible guiding system. The RPM system and our visible guiding system improve the respiratory regularity, which in turn should improve the accuracy and efficiency of RGRT.
Ruschin, Mark; Ma, Lijun; Verbakel, Wilko; Larson, David; Brown, Paul D.
2017-01-01
Abstract Over the past three decades several randomized trials have enabled evidence-based practice for patients presenting with limited brain metastases. These trials have focused on the role of surgery or stereotactic radiosurgery (SRS) with or without whole brain radiation therapy (WBRT). As a result, it is clear that local control should be optimized with surgery or SRS in patients with optimal prognostic factors presenting with up to 4 brain metastases. The routine use of adjuvant WBRT remains debatable, as although greater distant brain control rates are observed, there is no impact on survival, and modern outcomes suggest adverse effects from WBRT on patient cognition and quality of life. With dramatic technologic advances in radiation oncology facilitating the adoption of SRS into mainstream practice, the optimal management of patients with multiple brain metastases is now being put forward. Practice is evolving to SRS alone in these patients despite a lack of level 1 evidence to support a clinical departure from WBRT. The purpose of this review is to summarize the current state of the evidence for patients presenting with limited and multiple metastases, and to present an in-depth analysis of the technology and dosimetric issues specific to the treatment of multiple metastases. PMID:28380635
Accelerated gradient-based free form deformable registration for online adaptive radiotherapy
NASA Astrophysics Data System (ADS)
Yu, Gang; Liang, Yueqiang; Yang, Guanyu; Shu, Huazhong; Li, Baosheng; Yin, Yong; Li, Dengwang
2015-04-01
The registration of planning fan-beam computed tomography (FBCT) and daily cone-beam CT (CBCT) is a crucial step in adaptive radiation therapy. The current intensity-based registration algorithms, such as Demons, may fail when they are used to register FBCT and CBCT, because the CT numbers in CBCT cannot exactly correspond to the electron densities. In this paper, we investigated the effects of CBCT intensity inaccuracy on the registration accuracy and developed an accurate gradient-based free form deformation algorithm (GFFD). GFFD distinguishes itself from other free form deformable registration algorithms by (a) measuring the similarity using the 3D gradient vector fields to avoid the effect of inconsistent intensities between the two modalities; (b) accommodating image sampling anisotropy using the local polynomial approximation-intersection of confidence intervals (LPA-ICI) algorithm to ensure a smooth and continuous displacement field; and (c) introducing a ‘bi-directional’ force along with an adaptive force strength adjustment to accelerate the convergence process. It is expected that such a strategy can decrease the effect of the inconsistent intensities between the two modalities, thus improving the registration accuracy and robustness. Moreover, for clinical application, the algorithm was implemented by graphics processing units (GPU) through OpenCL framework. The registration time of the GFFD algorithm for each set of CT data ranges from 8 to 13 s. The applications of on-line adaptive image-guided radiation therapy, including auto-propagation of contours, aperture-optimization and dose volume histogram (DVH) in the course of radiation therapy were also studied by in-house-developed software.
Esophageal cancer management controversies: Radiation oncology point of view
Tai, Patricia; Yu, Edward
2014-01-01
Esophageal cancer treatment has evolved from single modality to trimodality therapy. There are some controversies of the role, target volumes and dose of radiotherapy (RT) in the literature over decades. The present review focuses primarily on RT as part of the treatment modalities, and highlight on the RT volume and its dose in the management of esophageal cancer. The randomized adjuvant chemoradiation (CRT) trial, intergroup trial (INT 0116) enrolled 559 patients with resected adenocarcinoma of the stomach or gastroesophageal junction. They were randomly assigned to surgery plus postoperative CRT or surgery alone. Analyses show robust treatment benefit of adjuvant CRT in most subsets for postoperative CRT. The Chemoradiotherapy for Oesophageal Cancer Followed by Surgery Study (CROSS) used a lower RT dose of 41.4 Gray in 23 fractions with newer chemotherapeutic agents carboplatin and paclitaxel to achieve an excellent result. Target volume of external beam radiation therapy and its coverage have been in debate for years among radiation oncologists. Pre-operative and post-operative target volumes are designed to optimize for disease control. Esophageal brachytherapy is effective in the palliation of dysphagia, but should not be given concomitantly with chemotherapy or external beam RT. The role of brachytherapy in multimodality management requires further investigation. On-going studies of multidisciplinary treatment in locally advanced cancer include: ZTOG1201 trial (a phase II trial of neoadjuvant and adjuvant CRT) and QUINTETT (a phase III trial of neoadjuvant vs adjuvant therapy with quality of life analysis). These trials hopefully will shed more light on the future management of esophageal cancer. PMID:25132924
WE-G-16A-01: Evolution of Radiation Treatment Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rothenberg, L; Mohan, R; Van Dyk, J
Welcome and Introduction - Lawrence N. Rothenberg This symposium is one a continuing series of presentations at AAPM Annual Meetings on the historical aspects of medical physics, radiology, and radiation oncology that have been organized by the AAPM History Committee. Information on previous presentations including “Early Developments in Teletherapy” (Indianapolis 2013), “Historical Aspects of Cross-Sectional Imaging” (Charlotte 2012), “Historical Aspects of Brachytherapy” (Vancouver 2011), “50 Years of Women in Medical Physics” (Houston 2008), and “Roentgen's Early Investigations” (Minneapolis 2007) can be found in the Education Section of the AAPM Website. The Austin 2014 History Symposium will be on “Evolution ofmore » Radiation Treatment Planning.” Overview - Radhe Mohan Treatment planning is one of the most critical components in the chain of radiation therapy of cancers. Treatment plans of today contain a wide variety of sophisticated information conveying the potential clinical effectiveness of the designed treatment to practitioners. Examples of such information include dose distributions superimposed on three- or even four-dimensional anatomic images; dose volume histograms, dose, dose-volume and dose-response indices for anatomic structures of interest; etc. These data are used for evaluating treatment plans and for making treatment decisions. The current state-of-the-art has evolved from the 1940s era when the dose to the tumor and normal tissues was estimated approximately by manual means. However, the symposium will cover the history of the field from the late-1950's, when computers were first introduced for treatment planning, to the present state involving the use of high performance computing and advanced multi-dimensional anatomic, functional and biological imaging, focusing only on external beam treatment planning. The symposium will start with a general overview of the treatment planning process including imaging, structure delineation, assignment of dose requirements, consideration of uncertainties, selection of beam configurations and shaping of beams, and calculations, optimization and evaluation of dose distributions. This will be followed by three presentations covering the evolution of treatment planning, which parallels the evolution of computers, availability of advanced volumetric imaging and the development of novel technologies such as dynamic multi-leaf collimators and online image guidance. This evolution will be divided over three distinct periods - prior to 1970's, the 2D era; from 1980 to the mid-1990's, the 3D era; and from the mid 1990's to today, the IMRT era. When the World was Flat: The Two-Dimensional Radiation Therapy Era” - Jacob Van Dyk In the 2D era, anatomy was defined with the aid of solder wires, special contouring devices and projection x-rays. Dose distributions were calculated manually from single field, flat surface isodoses on transparencies. Precalculated atlases of generic dose distributions were produced by the International Atomic Energy Agency. Massive time-shared main frames and mini-computers were used to compute doses at individual points or dose distributions in a single plane. Beam shapes were generally rectangular, with wedges, missing tissue compensators and occasional blocks to shield critical structures. Dose calculations were measurement-based or they used primary and scatter calculations based on scatter-air ratio methodologies. Dose distributions were displayed on line printers as alpha-numeric character maps or isodose patterns made with pen plotters. More than Pretty Pictures: 3D Treatment Planning and Conformal Therapy - Benedick A. Fraass The introduction of computed tomography allowed the delineation of anatomy three-dimensionally and, supported partly by contracts from the National Cancer Institute, made possible the introduction and clinical use of 3D treatment planning, leading to development and use of 3D conformal therapy in the 1980's. 3D computer graphics and 3D anatomical structure definitions made possible Beam's Eye View (BEV) displays, making conformal beam shaping and much more sophisticated beam arrangements possible. These conformal plans significantly improved target dose coverage as well as normal tissue sparing. The use of dose volume histograms, gross/clinical/planning target volumes, MRI and PET imaging, multileaf collimators, and computer-controlled treatment delivery made sophisticated planning approaches practical. The significant improvements in dose distributions and analysis achievable with 3D conformal therapy made possible formal dose escalation and normal tissue tolerance clinical studies that set new and improved expectations for improved local control and decreasing complications in many clinical sites. From the Art to the State of the Art: Inverse Planning and IMRT - Thomas R. Bortfeld While the potential of intensity modulation was recognized in the mid- 1980's, intensity-modulated radiotherapy (IMRT) did not become a reality until the mid-1990's. Broad beams of photons could be sub-divided into narrow beamlets whose intensities could be determined using sophisticated optimization algorithms to appropriately balance tumor dose with normal tissue sparing. The development of dynamic multi-leaf collimators (on conventional linear accelerators as well as in helical delivery devices) enabled the efficient delivery of IMRT. The evolution of IMRT planning is continuing in the form of Volumetric Modulated Arc Therapy (VMAT) and through advanced optimization tools, such as multi-criteria optimization, automated IMRT planning, and robust optimization to protect dose distributions against uncertainties. IMRT also facilitates “dose painting” in which different sub-volumes of the target are prescribed different doses. Clearly, these advancements are being made possible by the increasing power and lower cost of computers and developments in other fields such as imaging and operations research. Summary - Radhe Mohan The history does not end here. The advancement of treatment planning is expected to continue, leading to further automation and improvements in conformality and robustness of dose distributions, particularly in the area of particle therapy. Radiobiological modeling will gain emphasis as part of the planning process. Learning Objectives: The scope of changes in technology and the capabilities of radiation treatment planning The impact of these changes in the quality of treatment plans and optimality of dose distributions The impact of development in other fields (imaging, computers, operations research, etc.) on the evolution of radiation treatment planning.« less
Calcified basal ganglionic mass 12 years after radiation therapy for medulloblastoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lichtor, T.; Wollmann, R.L.; Brown, F.D.
1984-04-01
A patient treated 12 years previously with an operation and radiation therapy for a medulloblastoma developed weakness of the left hand and perivascular calcification involving the right internal capsule and caudate nucleus. These findings are considered possible long-term complications of the radiation therapy.
MR-guided radiation therapy: transformative technology and its role in the central nervous system
Tseng, Chia-Lin; Balter, James M.; Teng, Feifei; Parmar, Hemant A.; Sahgal, Arjun
2017-01-01
Abstract This review article describes advancement of magnetic resonance imaging technologies in radiation therapy planning, guidance, and adaptation of brain tumors. The potential for MR-guided radiation therapy to improve outcomes and the challenges in its adoption are discussed. PMID:28380637
Dosimetric advantages of IMPT over IMRT for laser-accelerated proton beams
NASA Astrophysics Data System (ADS)
Luo, W.; Li, J.; Fourkal, E.; Fan, J.; Xu, X.; Chen, Z.; Jin, L.; Price, R.; Ma, C.-M.
2008-12-01
As a clinical application of an exciting scientific breakthrough, a compact and cost-efficient proton therapy unit using high-power laser acceleration is being developed at Fox Chase Cancer Center. The significance of this application depends on whether or not it can yield dosimetric superiority over intensity-modulated radiation therapy (IMRT). The goal of this study is to show how laser-accelerated proton beams with broad energy spreads can be optimally used for proton therapy including intensity-modulated proton therapy (IMPT) and achieve dosimetric superiority over IMRT for prostate cancer. Desired energies and spreads with a varying δE/E were selected with the particle selection device and used to generate spread-out Bragg peaks (SOBPs). Proton plans were generated on an in-house Monte Carlo-based inverse-planning system. Fifteen prostate IMRT plans previously used for patient treatment have been included for comparison. Identical dose prescriptions, beam arrangement and consistent dose constrains were used for IMRT and IMPT plans to show the dosimetric differences that were caused only by the different physical characteristics of proton and photon beams. Different optimization constrains and beam arrangements were also used to find optimal IMPT. The results show that conventional proton therapy (CPT) plans without intensity modulation were not superior to IMRT, but IMPT can generate better proton plans if appropriate beam setup and optimization are used. Compared to IMRT, IMPT can reduce the target dose heterogeneity ((D5-D95)/D95) by up to 56%. The volume receiving 65 Gy and higher (V65) for the bladder and the rectum can be reduced by up to 45% and 88%, respectively, while the volume receiving 40 Gy and higher (V40) for the bladder and the rectum can be reduced by up to 49% and 68%, respectively. IMPT can also reduce the whole body non-target tissue dose by up to 61% or a factor 2.5. This study has shown that the laser accelerator under development has a potential to generate high-quality proton beams for cancer treatment. Significant improvement in target dose uniformity and normal tissue sparing as well as in reduction of whole body dose can be achieved by IMPT with appropriate optimization and beam setup.
Prostate cancer patients who have failed standard radiation therapy have the options of surgery, radioactive seed implantation or cryoablation. Deborah Citrin, M.D., of the Radiation Oncology Branch is leading a study of stereotactic body radiation therapy (SBRT) to treat prostate cancer that has recurred locally after standard radiation therapy. The goal of this study is to
Cherenkov Video Imaging Allows for the First Visualization of Radiation Therapy in Real Time
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jarvis, Lesley A., E-mail: Lesley.a.jarvis@hitchcock.org; Norris Cotton Cancer Center at the Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire; Zhang, Rongxiao
Purpose: To determine whether Cherenkov light imaging can visualize radiation therapy in real time during breast radiation therapy. Methods and Materials: An intensified charge-coupled device (CCD) camera was synchronized to the 3.25-μs radiation pulses of the clinical linear accelerator with the intensifier set × 100. Cherenkov images were acquired continuously (2.8 frames/s) during fractionated whole breast irradiation with each frame an accumulation of 100 radiation pulses (approximately 5 monitor units). Results: The first patient images ever created are used to illustrate that Cherenkov emission can be visualized as a video during conditions typical for breast radiation therapy, even with complex treatment plans,more » mixed energies, and modulated treatment fields. Images were generated correlating to the superficial dose received by the patient and potentially the location of the resulting skin reactions. Major blood vessels are visible in the image, providing the potential to use these as biological landmarks for improved geometric accuracy. The potential for this system to detect radiation therapy misadministrations, which can result from hardware malfunction or patient positioning setup errors during individual fractions, is shown. Conclusions: Cherenkoscopy is a unique method for visualizing surface dose resulting in real-time quality control. We propose that this system could detect radiation therapy errors in everyday clinical practice at a time when these errors can be corrected to result in improved safety and quality of radiation therapy.« less
Lin, Steven H.
2011-01-01
The standard of care for the management of locally advanced esophageal cancers in the United States is chemotherapy combined with radiation, either definitively, or for those who could tolerate surgery, preoperatively before esophagectomy. Although the appropriate radiation dose remains somewhat controversial, the quality of the radiation delivery is critical for the treatment of esophageal cancer since the esophagus is positioned close to vital structures, such as the heart and lung. The volume and relative doses to these normal tissues affect acute and late term complications. Advances in radiation delivery from 2D to 3D conformal radiation therapy, to Intensity Modulated Radiation Therapy (IMRT) or charged particle therapy (carbon ion or proton beam therapy (PBT)), allow incremental improvements in the therapeutic ratio. This could have implications in non-cancer related morbidity for long term survivors. This article reviews the evolution in radiation technologies and the use of PBT with chemotherapy in the management of esophageal cancer. PMID:24213126
Mladenov, Emil; Magin, Simon; Soni, Aashish; Iliakis, George
2013-01-01
Radiation therapy plays an important role in the management of a wide range of cancers. Besides innovations in the physical application of radiation dose, radiation therapy is likely to benefit from novel approaches exploiting differences in radiation response between normal and tumor cells. While ionizing radiation induces a variety of DNA lesions, including base damages and single-strand breaks, the DNA double-strand break (DSB) is widely considered as the lesion responsible not only for the aimed cell killing of tumor cells, but also for the general genomic instability that leads to the development of secondary cancers among normal cells. Homologous recombination repair (HRR), non-homologous end-joining (NHEJ), and alternative NHEJ, operating as a backup, are the major pathways utilized by cells for the processing of DSBs. Therefore, their function represents a major mechanism of radiation resistance in tumor cells. HRR is also required to overcome replication stress – a potent contributor to genomic instability that fuels cancer development. HRR and alternative NHEJ show strong cell-cycle dependency and are likely to benefit from radiation therapy mediated redistribution of tumor cells throughout the cell-cycle. Moreover, the synthetic lethality phenotype documented between HRR deficiency and PARP inhibition has opened new avenues for targeted therapies. These observations make HRR a particularly intriguing target for treatments aiming to improve the efficacy of radiation therapy. Here, we briefly describe the major pathways of DSB repair and review their possible contribution to cancer cell radioresistance. Finally, we discuss promising alternatives for targeting DSB repair to improve radiation therapy and cancer treatment. PMID:23675572
Strategies to Improve Cancer Photothermal Therapy Mediated by Nanomaterials.
de Melo-Diogo, Duarte; Pais-Silva, Cleide; Dias, Diana R; Moreira, André F; Correia, Ilídio J
2017-05-01
The deployment of hyperthermia-based treatments for cancer therapy has captured the attention of different researchers worldwide. In particular, the application of light-responsive nanomaterials to mediate hyperthermia has revealed promising results in several pre-clinical assays. Unlike conventional therapies, these nanostructures can display a preferential tumor accumulation and thus mediate, upon irradiation with near-infrared light, a selective hyperthermic effect with temporal resolution. Different types of nanomaterials such as those based on gold, carbon, copper, molybdenum, tungsten, iron, palladium and conjugated polymers have been used for this photothermal modality. This progress report summarizes the different strategies that have been applied so far for increasing the efficacy of the photothermal therapeutic effect mediated by nanomaterials, namely those that improve the accumulation of nanomaterials in tumors (e.g. by changing the corona composition or through the functionalization with targeting ligands), increase nanomaterials' intrinsic capacity to generate photoinduced heat (e.g. by synthesizing new nanomaterials or assembling nanostructures) or by optimizing the parameters related to the laser light used in the irradiation process (e.g. by modulating the radiation wavelength). Overall, the development of new strategies or the optimization and combination of the existing ones will surely give a major contribution for the application of nanomaterials in cancer PTT. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
[Radiation therapy and redox imaging].
Matsumoto, Ken-ichiro
2015-01-01
Radiation therapy kills cancer cells in part by flood of free radicals. Radiation ionizes and/or excites water molecules to create highly reactive species, i.e. free radicals and/or reactive oxygen species. Free radical chain reactions oxidize biologically important molecules and thereby disrupt their function. Tissue oxygen and/or redox status, which can influence the course of the free radical chain reaction, can affect the efficacy of radiation therapy. Prior observation of tissue oxygen and/or redox status is helpful for planning a safe and efficient course of radiation therapy. Magnetic resonance-based redox imaging techniques, which can estimate tissue redox status non-invasively, have been developed not only for diagnostic information but also for estimating the efficacy of treatment. Redox imaging is now spotlighted to achieve radiation theranostics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Nan; Carmona, Ruben; Sirak, Igor
Purpose: To demonstrate an efficient method for training and validation of a knowledge-based planning (KBP) system as a radiation therapy clinical trial plan quality-control system. Methods and Materials: We analyzed 86 patients with stage IB through IVA cervical cancer treated with intensity modulated radiation therapy at 2 institutions according to the standards of the INTERTECC (International Evaluation of Radiotherapy Technology Effectiveness in Cervical Cancer, National Clinical Trials Network identifier: 01554397) protocol. The protocol used a planning target volume and 2 primary organs at risk: pelvic bone marrow (PBM) and bowel. Secondary organs at risk were rectum and bladder. Initial unfiltered dose-volumemore » histogram (DVH) estimation models were trained using all 86 plans. Refined training sets were created by removing sub-optimal plans from the unfiltered sample, and DVH estimation models… and DVH estimation models were constructed by identifying 30 of 86 plans emphasizing PBM sparing (comparing protocol-specified dosimetric cutpoints V{sub 10} (percentage volume of PBM receiving at least 10 Gy dose) and V{sub 20} (percentage volume of PBM receiving at least 20 Gy dose) with unfiltered predictions) and another 30 of 86 plans emphasizing bowel sparing (comparing V{sub 40} (absolute volume of bowel receiving at least 40 Gy dose) and V{sub 45} (absolute volume of bowel receiving at least 45 Gy dose), 9 in common with the PBM set). To obtain deliverable KBP plans, refined models must inform patient-specific optimization objectives and/or priorities (an auto-planning “routine”). Four candidate routines emphasizing different tradeoffs were composed, and a script was developed to automatically re-plan multiple patients with each routine. After selection of the routine that best met protocol objectives in the 51-patient training sample (KBP{sub FINAL}), protocol-specific DVH metrics and normal tissue complication probability were compared for original versus KBP{sub FINAL} plans across the 35-patient validation set. Paired t tests were used to test differences between planning sets. Results: KBP{sub FINAL} plans outperformed manual planning across the validation set in all protocol-specific DVH cutpoints. The mean normal tissue complication probability for gastrointestinal toxicity was lower for KBP{sub FINAL} versus validation-set plans (48.7% vs 53.8%, P<.001). Similarly, the estimated mean white blood cell count nadir was higher (2.77 vs 2.49 k/mL, P<.001) with KBP{sub FINAL} plans, indicating lowered probability of hematologic toxicity. Conclusions: This work demonstrates that a KBP system can be efficiently trained and refined for use in radiation therapy clinical trials with minimal effort. This patient-specific plan quality control resulted in improvements on protocol-specific dosimetric endpoints.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, Jonathan; Xu, Beibei; Moores Cancer Center, University of California San Diego, La Jolla, California
Purpose/Objective: Palliative radiation therapy represents an important treatment option among patients with advanced cancer, although research shows decreased use among older patients. This study evaluated age-related patterns of palliative radiation use among an elderly Medicare population. Methods and Materials: We identified 63,221 patients with metastatic lung, breast, prostate, or colorectal cancer diagnosed between 2000 and 2007 from the Surveillance, Epidemiology, and End Results (SEER)-Medicare linked database. Receipt of palliative radiation therapy was extracted from Medicare claims. Multivariate Poisson regression analysis determined residual age-related disparity in the receipt of palliative radiation therapy after controlling for confounding covariates including age-related differences inmore » patient and demographic covariates, length of life, and patient preferences for aggressive cancer therapy. Results: The use of radiation decreased steadily with increasing patient age. Forty-two percent of patients aged 66 to 69 received palliative radiation therapy. Rates of palliative radiation decreased to 38%, 32%, 24%, and 14% among patients aged 70 to 74, 75 to 79, 80 to 84, and over 85, respectively. Multivariate analysis found that confounding covariates attenuated these findings, although the decreased relative rate of palliative radiation therapy among the elderly remained clinically and statistically significant. On multivariate analysis, compared to patients 66 to 69 years old, those aged 70 to 74, 75 to 79, 80 to 84, and over 85 had a 7%, 15%, 25%, and 44% decreased rate of receiving palliative radiation, respectively (all P<.0001). Conclusions: Age disparity with palliative radiation therapy exists among older cancer patients. Further research should strive to identify barriers to palliative radiation among the elderly, and extra effort should be made to give older patients the opportunity to receive this quality of life-enhancing treatment at the end of life.« less
Brachial Plexus-Associated Neuropathy After High-Dose Radiation Therapy for Head-and-Neck Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Allen M., E-mail: allen.chen@ucdmc.ucdavis.edu; Hall, William H.; Li, Judy
2012-09-01
Purpose: To identify clinical and treatment-related predictors of brachial plexus-associated neuropathies after radiation therapy for head-and-neck cancer. Methods and Materials: Three hundred thirty patients who had previously completed radiation therapy for head-and-neck cancer were prospectively screened using a standardized instrument for symptoms of neuropathy thought to be related to brachial plexus injury. All patients were disease-free at the time of screening. The median time from completion of radiation therapy was 56 months (range, 6-135 months). One-hundred fifty-five patients (47%) were treated by definitive radiation therapy, and 175 (53%) were treated postoperatively. Radiation doses ranged from 50 to 74 Gy (median,more » 66 Gy). Intensity-modulated radiation therapy was used in 62% of cases, and 133 patients (40%) received concurrent chemotherapy. Results: Forty patients (12%) reported neuropathic symptoms, with the most common being ipsilateral pain (50%), numbness/tingling (40%), motor weakness, and/or muscle atrophy (25%). When patients with <5 years of follow-up were excluded, the rate of positive symptoms increased to 22%. On univariate analysis, the following factors were significantly associated with brachial plexus symptoms: prior neck dissection (p = 0.01), concurrent chemotherapy (p = 0.01), and radiation maximum dose (p < 0.001). Cox regression analysis confirmed that both neck dissection (p < 0.001) and radiation maximum dose (p < 0.001) were independently predictive of symptoms. Conclusion: The incidence of brachial plexus-associated neuropathies after radiation therapy for head-and-neck cancer may be underreported. In view of the dose-response relationship identified, limiting radiation dose to the brachial plexus should be considered when possible.« less
[Brain metastases: Focal treatment (surgery and radiation therapy) and cognitive consequences].
Reygagne, Emmanuelle; Du Boisgueheneuc, Foucaud; Berger, Antoine
2017-04-01
Brain metastases represent the first cause of malignant brain tumor. Without radiation therapy, prognosis was poor with fast neurological deterioration, and a median overall survival of one month. Nowadays, therapeutic options depend on brain metastases presentation, extra brain disease, performance status and estimated prognostic (DS GPA). Therefore, for oligometastatic brain patients with a better prognosis, this therapeutic modality is controversial. In fact, whole-brain radiation therapy improves neurological outcomes, but it can also induce late neuro-cognitive sequelae for long-term survivors of brain metastases. Thus, in this strategy for preserving good cognitive functions, stereotactic radiation therapy is a promising treatment. Delivering precisely targeted radiation in few high-doses in one to four brain metastases, allows to reduce radiation damage to normal tissues and it should allow to decrease radiation-induced cognitive decline. In this paper, we will discuss about therapeutic strategies (radiation therapy and surgery) with their neuro-cognitive consequences for brain metastases patients and future concerning preservation of cognitive functions. Copyright © 2016 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.
Future Directions in Medical Physics
NASA Astrophysics Data System (ADS)
Jeraj, Robert
Medical Physics is a highly interdisciplinary field at the intersection between physics and medicine and biology. Medical Physics is aiming at development of novel applications of physical processes and techniques in various areas of medicine and biology. Medical Physics had and continues to have profound impact by developing improved imaging and treatment technologies, and helping to advance our understanding of the complexity of the disease. The general trend in medicine towards personalized therapy, and emphasis on accelerated translational research is having a profound impact on medical physics as well. In the traditional stronghold for medical physicists - radiation therapy - the new reality is shaping in the form of biologically conformal and combination therapies, as well as advanced particle therapy approaches, such as proton and ion therapies. Rapid increase in faster and more informative multi-modality medical imaging is bringing a wealth of information that is being complemented with data obtained from genomic profiling and other biomarkers. Novel data analysis and data mining approaches are proving grounds for employment of various artificial intelligence methods that will help further improving clinical decision making for optimization of various therapies as well as better understanding of the disease properties and disease evolution, ultimately leading to improved clinical outcomes.
Strategies for improving the intratumoral distribution of liposomal drugs in cancer therapy
Goins, Beth; Phillips, William T.; Bao, Ande
2016-01-01
Introduction A major limitation of current liposomal cancer therapies is the inability of liposome therapeutics to penetrate throughout the entire tumor mass. This inhomogeneous distribution of liposome therapeutics within the tumor has been linked to treatment failure and drug resistance. Both liposome particle transport properties and tumor microenvironment characteristics contribute to this challenge in cancer therapy. This limitation is relevant to both intravenously and intratumorally administered liposome therapeutics. Areas covered Strategies to improve the intratumoral distribution of liposome therapeutics are described. Combination therapies of intravenous liposome therapeutics with pharmacologic agents modulating abnormal tumor vasculature, interstitial fluid pressure, extracellular matrix components, and tumor associated macrophages are discussed. Combination therapies using external stimuli (hyperthermia, radiofrequency ablation, magnetic field, radiation, and ultrasound) with intravenous liposome therapeutics are discussed. Intratumoral convection-enhanced delivery (CED) of liposomal therapeutics is reviewed. Expert opinion Optimization of the combination therapies and drug delivery protocols are necessary. Further research should be conducted in appropriate cancer types with consideration of physiochemical features of liposomes and their timing sequence. More investigation of the role of tumor associated macrophages in intratumoral distribution is warranted. Intratumoral infusion of liposomes using CED is a promising approach to improve their distribution within the tumor mass. PMID:26981891
Derivative-free generation and interpolation of convex Pareto optimal IMRT plans
NASA Astrophysics Data System (ADS)
Hoffmann, Aswin L.; Siem, Alex Y. D.; den Hertog, Dick; Kaanders, Johannes H. A. M.; Huizenga, Henk
2006-12-01
In inverse treatment planning for intensity-modulated radiation therapy (IMRT), beamlet intensity levels in fluence maps of high-energy photon beams are optimized. Treatment plan evaluation criteria are used as objective functions to steer the optimization process. Fluence map optimization can be considered a multi-objective optimization problem, for which a set of Pareto optimal solutions exists: the Pareto efficient frontier (PEF). In this paper, a constrained optimization method is pursued to iteratively estimate the PEF up to some predefined error. We use the property that the PEF is convex for a convex optimization problem to construct piecewise-linear upper and lower bounds to approximate the PEF from a small initial set of Pareto optimal plans. A derivative-free Sandwich algorithm is presented in which these bounds are used with three strategies to determine the location of the next Pareto optimal solution such that the uncertainty in the estimated PEF is maximally reduced. We show that an intelligent initial solution for a new Pareto optimal plan can be obtained by interpolation of fluence maps from neighbouring Pareto optimal plans. The method has been applied to a simplified clinical test case using two convex objective functions to map the trade-off between tumour dose heterogeneity and critical organ sparing. All three strategies produce representative estimates of the PEF. The new algorithm is particularly suitable for dynamic generation of Pareto optimal plans in interactive treatment planning.
Radiation Therapy Side Effects
Radiation therapy has side effects because it not only kills or slows the growth of cancer cells, it can also affect nearby healthy cells. Many people who get radiation therapy experience fatigue. Other side effects depend on the part of the body that is being treated. Learn more about possible side effects.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-16
... Area ICD International Classification of Diseases IMRT Intensity Modulated Radiation Therapy IOM... Stereotactic body radiation therapy SGR Sustainable growth rate TC Technical component TIN Tax identification... Clinical Lab Fee Schedule, which is unaffected by the misvalued code initiative. Radiation therapy centers...
21 CFR 892.5710 - Radiation therapy beam-shaping block.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiation therapy beam-shaping block. 892.5710 Section 892.5710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5710 Radiation therapy beam-shaping...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, Carolyn W., E-mail: carolyn.taylor@ctsu.ox.ac.uk; Wang, Zhe; Macaulay, Elizabeth
Purpose: Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Methods and Materials: Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this “mean heart dose.” Results: In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28more » countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Conclusions: Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose.« less
NASA Astrophysics Data System (ADS)
Musabaeva, L. I.; Startseva, Zh. A.; Gribova, O. V.; Velikaya, V. V.; Lisin, V. A.
2016-08-01
The analysis of clinical use of neutron therapy with 6 MeV fast neutrons compared to conventional radiation therapy was carried out. The experience of using neutron and mixed neutron and photon therapy in patients with different radio-resistant malignant tumors shows the necessity of further studies and development of the novel approaches to densely-ionizing radiation. The results of dosimetry and radiobiological studies have been the basis for planning clinical programs for neutron therapy. Clinical trials over the past 30 years have shown that neutron therapy successfully destroys radio-resistant cancers, including salivary gland tumors, adenoidcystic carcinoma, inoperable sarcomas, locally advanced head and neck tumors, and locally advanced prostate cancer. Radiation therapy with 6.3 MeV fast neutrons used alone and in combination with photon therapy resulted in improved long-term treatment outcomes in patients with radio-resistant malignant tumors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nguyen, Kham, E-mail: khamdiep@gmail.com; UT MD Anderson Cancer Center, School of Health Professions—Unit 2, Houston, TX; Cummings, David
The purpose of this study was to evaluate the differences between volumetric modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) in the treatment of nasal cavity carcinomas. The treatment of 10 patients, who had completed IMRT treatment for resected tumors of the nasal cavity, was replanned with the Philips Pinnacle{sup 3} Version 9 treatment-planning system. The IMRT plans used a 9-beam technique whereas the VMAT (known as SmartArc) plans used a 3-arc technique. Both types of plans were optimized using Philips Pinnacle{sup 3} Direct Machine Parameter Optimization algorithm. IMRT and VMAT plans' quality was compared by evaluating the maximum,more » minimum, and mean doses to the target volumes and organs at risk, monitor units (MUs), and the treatment delivery time. Our results indicate that VMAT is capable of greatly reducing treatment delivery time and MUs compared with IMRT. The reduction of treatment delivery time and MUs can decrease the effects of intrafractional uncertainties that can occur because of patient movement during treatment delivery. VMAT's plans further reduce doses to critical structures that are in close proximity to the target volume.« less
In-Space Radiator Shape Optimization using Genetic Algorithms
NASA Technical Reports Server (NTRS)
Hull, Patrick V.; Kittredge, Ken; Tinker, Michael; SanSoucie, Michael
2006-01-01
Future space exploration missions will require the development of more advanced in-space radiators. These radiators should be highly efficient and lightweight, deployable heat rejection systems. Typical radiators for in-space heat mitigation commonly comprise a substantial portion of the total vehicle mass. A small mass savings of even 5-10% can greatly improve vehicle performance. The objective of this paper is to present the development of detailed tools for the analysis and design of in-space radiators using evolutionary computation techniques. The optimality criterion is defined as a two-dimensional radiator with a shape demonstrating the smallest mass for the greatest overall heat transfer, thus the end result is a set of highly functional radiator designs. This cross-disciplinary work combines topology optimization and thermal analysis design by means of a genetic algorithm The proposed design tool consists of the following steps; design parameterization based on the exterior boundary of the radiator, objective function definition (mass minimization and heat loss maximization), objective function evaluation via finite element analysis (thermal radiation analysis) and optimization based on evolutionary algorithms. The radiator design problem is defined as follows: the input force is a driving temperature and the output reaction is heat loss. Appropriate modeling of the space environment is added to capture its effect on the radiator. The design parameters chosen for this radiator shape optimization problem fall into two classes, variable height along the width of the radiator and a spline curve defining the -material boundary of the radiator. The implementation of multiple design parameter schemes allows the user to have more confidence in the radiator optimization tool upon demonstration of convergence between the two design parameter schemes. This tool easily allows the user to manipulate the driving temperature regions thus permitting detailed design of in-space radiators for unique situations. Preliminary results indicate an optimized shape following that of the temperature distribution regions in the "cooler" portions of the radiator. The results closely follow the expected radiator shape.
Implant therapy - prostate cancer; Radioactive seed placement; Internal radiation therapy - prostate; High dose radiation (HDR) ... CT scan to plan and then place the seeds that deliver radiation into your prostate. The seeds ...
Determination of MLC model parameters for Monaco using commercial diode arrays.
Kinsella, Paul; Shields, Laura; McCavana, Patrick; McClean, Brendan; Langan, Brian
2016-07-08
Multileaf collimators (MLCs) need to be characterized accurately in treatment planning systems to facilitate accurate intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). The aim of this study was to examine the use of MapCHECK 2 and ArcCHECK diode arrays for optimizing MLC parameters in Monaco X-ray voxel Monte Carlo (XVMC) dose calculation algorithm. A series of radiation test beams designed to evaluate MLC model parameters were delivered to MapCHECK 2, ArcCHECK, and EBT3 Gafchromic film for comparison. Initial comparison of the calculated and ArcCHECK-measured dose distributions revealed it was unclear how to change the MLC parameters to gain agreement. This ambiguity arose due to an insufficient sampling of the test field dose distributions and unexpected discrepancies in the open parts of some test fields. Consequently, the XVMC MLC parameters were optimized based on MapCHECK 2 measurements. Gafchromic EBT3 film was used to verify the accuracy of MapCHECK 2 measured dose distributions. It was found that adjustment of the MLC parameters from their default values resulted in improved global gamma analysis pass rates for MapCHECK 2 measurements versus calculated dose. The lowest pass rate of any MLC-modulated test beam improved from 68.5% to 93.5% with 3% and 2 mm gamma criteria. Given the close agreement of the optimized model to both MapCHECK 2 and film, the optimized model was used as a benchmark to highlight the relatively large discrepancies in some of the test field dose distributions found with ArcCHECK. Comparison between the optimized model-calculated dose and ArcCHECK-measured dose resulted in global gamma pass rates which ranged from 70.0%-97.9% for gamma criteria of 3% and 2 mm. The simple square fields yielded high pass rates. The lower gamma pass rates were attributed to the ArcCHECK overestimating the dose in-field for the rectangular test fields whose long axis was parallel to the long axis of the ArcCHECK. Considering ArcCHECK measurement issues and the lower gamma pass rates for the MLC-modulated test beams, it was concluded that MapCHECK 2 was a more suitable detector than ArcCHECK for the optimization process. © 2016 The Authors
Song, Ting; Li, Nan; Zarepisheh, Masoud; Li, Yongbao; Gautier, Quentin; Zhou, Linghong; Mell, Loren; Jiang, Steve; Cerviño, Laura
2016-01-01
Intensity-modulated radiation therapy (IMRT) currently plays an important role in radiotherapy, but its treatment plan quality can vary significantly among institutions and planners. Treatment plan quality control (QC) is a necessary component for individual clinics to ensure that patients receive treatments with high therapeutic gain ratios. The voxel-weighting factor-based plan re-optimization mechanism has been proved able to explore a larger Pareto surface (solution domain) and therefore increase the possibility of finding an optimal treatment plan. In this study, we incorporated additional modules into an in-house developed voxel weighting factor-based re-optimization algorithm, which was enhanced as a highly automated and accurate IMRT plan QC tool (TPS-QC tool). After importing an under-assessment plan, the TPS-QC tool was able to generate a QC report within 2 minutes. This QC report contains the plan quality determination as well as information supporting the determination. Finally, the IMRT plan quality can be controlled by approving quality-passed plans and replacing quality-failed plans using the TPS-QC tool. The feasibility and accuracy of the proposed TPS-QC tool were evaluated using 25 clinically approved cervical cancer patient IMRT plans and 5 manually created poor-quality IMRT plans. The results showed high consistency between the QC report quality determinations and the actual plan quality. In the 25 clinically approved cases that the TPS-QC tool identified as passed, a greater difference could be observed for dosimetric endpoints for organs at risk (OAR) than for planning target volume (PTV), implying that better dose sparing could be achieved in OAR than in PTV. In addition, the dose-volume histogram (DVH) curves of the TPS-QC tool re-optimized plans satisfied the dosimetric criteria more frequently than did the under-assessment plans. In addition, the criteria for unsatisfied dosimetric endpoints in the 5 poor-quality plans could typically be satisfied when the TPS-QC tool generated re-optimized plans without sacrificing other dosimetric endpoints. In addition to its feasibility and accuracy, the proposed TPS-QC tool is also user-friendly and easy to operate, both of which are necessary characteristics for clinical use. PMID:26930204
Liu, Wei; Liao, Zhongxing; Schild, Steven E; Liu, Zhong; Li, Heng; Li, Yupeng; Park, Peter C; Li, Xiaoqiang; Stoker, Joshua; Shen, Jiajian; Keole, Sameer; Anand, Aman; Fatyga, Mirek; Dong, Lei; Sahoo, Narayan; Vora, Sujay; Wong, William; Zhu, X Ronald; Bues, Martin; Mohan, Radhe
2015-01-01
We compared conventionally optimized intensity modulated proton therapy (IMPT) treatment plans against worst-case scenario optimized treatment plans for lung cancer. The comparison of the 2 IMPT optimization strategies focused on the resulting plans' ability to retain dose objectives under the influence of patient setup, inherent proton range uncertainty, and dose perturbation caused by respiratory motion. For each of the 9 lung cancer cases, 2 treatment plans were created that accounted for treatment uncertainties in 2 different ways. The first used the conventional method: delivery of prescribed dose to the planning target volume that is geometrically expanded from the internal target volume (ITV). The second used a worst-case scenario optimization scheme that addressed setup and range uncertainties through beamlet optimization. The plan optimality and plan robustness were calculated and compared. Furthermore, the effects on dose distributions of changes in patient anatomy attributable to respiratory motion were investigated for both strategies by comparing the corresponding plan evaluation metrics at the end-inspiration and end-expiration phase and absolute differences between these phases. The mean plan evaluation metrics of the 2 groups were compared with 2-sided paired Student t tests. Without respiratory motion considered, we affirmed that worst-case scenario optimization is superior to planning target volume-based conventional optimization in terms of plan robustness and optimality. With respiratory motion considered, worst-case scenario optimization still achieved more robust dose distributions to respiratory motion for targets and comparable or even better plan optimality (D95% ITV, 96.6% vs 96.1% [P = .26]; D5%- D95% ITV, 10.0% vs 12.3% [P = .082]; D1% spinal cord, 31.8% vs 36.5% [P = .035]). Worst-case scenario optimization led to superior solutions for lung IMPT. Despite the fact that worst-case scenario optimization did not explicitly account for respiratory motion, it produced motion-resistant treatment plans. However, further research is needed to incorporate respiratory motion into IMPT robust optimization. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGeachy, P; Villarreal-Barajas, JE; Khan, R
2015-06-15
Purpose: The dosimetric outcome of optimized treatment plans obtained by modulating the photon beamlet energy and fluence on a small cohort of four Head and Neck (H and N) patients was investigated. This novel optimization technique is denoted XMRT for modulated photon radiotherapy. The dosimetric plans from XMRT for H and N treatment were compared to conventional, 6 MV intensity modulated radiotherapy (IMRT) optimization plans. Methods: An arrangement of two non-coplanar and five coplanar beams was used for all four H and N patients. Both XMRT and IMRT were subject to the same optimization algorithm, with XMRT optimization allowing bothmore » 6 and 18 MV beamlets while IMRT was restricted to 6 MV only. The optimization algorithm was based on a linear programming approach with partial-volume constraints implemented via the conditional value-at-risk method. H and N constraints were based off of those mentioned in the Radiation Therapy Oncology Group 1016 protocol. XMRT and IMRT solutions were assessed using metrics suggested by International Commission on Radiation Units and Measurements report 83. The Gurobi solver was used in conjunction with the CVX package to solve each optimization problem. Dose calculations and analysis were done in CERR using Monte Carlo dose calculation with VMC{sub ++}. Results: Both XMRT and IMRT solutions met all clinical criteria. Trade-offs were observed between improved dose uniformity to the primary target volume (PTV1) and increased dose to some of the surrounding healthy organs for XMRT compared to IMRT. On average, IMRT improved dose to the contralateral parotid gland and spinal cord while XMRT improved dose to the brainstem and mandible. Conclusion: Bi-energy XMRT optimization for H and N patients provides benefits in terms of improved dose uniformity to the primary target and reduced dose to some healthy structures, at the expense of increased dose to other healthy structures when compared with IMRT.« less
Boero, Isabel J; Gillespie, Erin F; Hou, Jiayi; Paravati, Anthony J; Kim, Ellen; Einck, John P; Yashar, Catheryn; Mell, Loren K; Murphy, James D
2017-03-01
Despite multiple randomized trials showing the efficacy of hypofractionated radiation therapy in early-stage breast cancer, the United States has been slow to adopt this treatment. The goal of this study was to evaluate the impact of individual radiation oncologists on the early adoption of hypofractionated radiation therapy for early-stage breast cancer. We identified 22,233 Medicare beneficiaries with localized breast cancer that was diagnosed from 2004 to 2011 who underwent breast-conserving surgery with adjuvant radiation. Multilevel, multivariable logistic models clustered by radiation oncologist and geographic practice area were used to determine the impact of the provider and geographic region on the likelihood of receiving hypofractionated compared with standard fractionated radiation therapy while controlling for a patient's clinical and demographic covariates. Odds ratios (OR) describe the impact of demographic or clinical covariates, and the median OR (MOR) describes the relative impact of the individual radiation oncologist and geographic region on the likelihood of undergoing hypofractionated radiation therapy. Among the entire cohort, 2333 women (10.4%) were treated with hypofractionated radiation therapy, with unadjusted rates ranging from 0.0% in the bottom quintile of radiation oncologists to 30.4% in the top quintile. Multivariable analysis found that the individual radiation oncologist (MOR 3.08) had a greater impact on the use of hypofractionation than did geographic region (MOR 2.10) or clinical and demographic variables. The impact of the provider increased from the year 2004 to 2005 (MOR 2.82) to the year 2010 to 2011 (MOR 3.16) despite the publication of long-term randomized trial results in early 2010. Male physician and radiation oncologists treating the highest volume of breast cancer patients were less likely to perform hypofractionation (P<.05). The individual radiation oncologist strongly influenced the likelihood of a patient's receiving hypofractionated radiation therapy, and this trend increased despite the publication of long-term data showing equivalence to standard fractionation. Future research should focus on physician-related factors that influence this decision. Copyright © 2016 Elsevier Inc. All rights reserved.
Adjuvant Radiation Therapy Treatment Time Impacts Overall Survival in Gastric Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMillan, Matthew T.; Department of Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania; Ojerholm, Eric
Purpose: Prolonged radiation therapy treatment time (RTT) is associated with worse survival in several tumor types. This study investigated whether delays during adjuvant radiation therapy impact overall survival (OS) in gastric cancer. Methods and Materials: The National Cancer Data Base was queried for patients with resected gastric cancer who received adjuvant radiation therapy with National Comprehensive Cancer Network–recommended doses (45 or 50.4 Gy) between 1998 and 2006. RTT was classified as standard (45 Gy: 33-36 days, 50.4 Gy: 38-41 days) or prolonged (45 Gy: >36 days, 50.4 Gy: >41 days). Cox proportional hazards models evaluated the association between the following factors and OS: RTT, interval from surgery to radiationmore » therapy initiation, interval from surgery to radiation therapy completion, radiation therapy dose, demographic/pathologic and operative factors, and other elements of adjuvant multimodality therapy. Results: Of 1591 patients, RTT was delayed in 732 (46%). Factors associated with prolonged RTT were non-private health insurance (OR 1.3, P=.005) and treatment at non-academic facilities (OR 1.2, P=.045). Median OS and 5-year actuarial survival were significantly worse in patients with prolonged RTT compared with standard RTT (36 vs 51 months, P=.001; 39 vs 47%, P=.005); OS worsened with each cumulative week of delay (P<.0004). On multivariable analysis, prolonged RTT was associated with inferior OS (hazard ratio 1.2, P=.002); the intervals from surgery to radiation therapy initiation or completion were not. Prolonged RTT was particularly detrimental in patients with node positivity, inadequate nodal staging (<15 nodes examined), and those undergoing a cycle of chemotherapy before chemoradiation therapy. Conclusions: Delays during adjuvant radiation therapy appear to negatively impact survival in gastric cancer. Efforts to minimize cumulative interruptions to <7 days should be considered.« less
Patel, Chirayu G; Stavas, Mark; Perkins, Stephanie; Shinohara, Eric T
2017-07-01
To investigate the determinants of radiation therapy refusal in pediatric cancer, we used the Surveillance, Epidemiology, and End Results registry to identify 24,421 patients who met the eligibility criteria, diagnosed between 1974 and 2012. Patients had any stage of cancer, were aged 0 to 19, and received radiation therapy or refused radiation therapy when it was recommended. One hundred twenty-eight patients (0.52%) refused radiation therapy when it was recommended. Thirty-two percent of patients who refused radiation therapy ultimately died from their cancer, at a median of 7 months after diagnosis (95% confidence interval, 3-11 mo), as compared with 29.0% of patients who did not refuse radiation therapy died from their cancer, at a median of 17 months after diagnosis (95% confidence interval, 17-18 mo). On multivariable analysis, central nervous system (CNS) site, education, and race were associated with radiation refusal. The odds ratio for radiation refusal for patients with CNS disease was 1.62 (P=0.009) as compared with patients without CNS disease. For patients living in a county with ≥10% residents having less than ninth grade education, the odds ratio for radiation refusal was 1.71 (P=0.008) as compared with patients living in a county with <10% residents having less than ninth grade education. Asian, Pacific Islander, Alaska Native, and American Indian races had an odds ratio of 2.12 (P=0.002) for radiation refusal as compared with black or white race. Although the radiation refusal rate in the pediatric cancer population is low, we show that CNS site, education level, and race are associated with a significant difference in radiation refusal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Minsun, E-mail: mk688@uw.edu; Stewart, Robert D.; Phillips, Mark H.
2015-11-15
Purpose: To investigate the impact of using spatiotemporal optimization, i.e., intensity-modulated spatial optimization followed by fractionation schedule optimization, to select the patient-specific fractionation schedule that maximizes the tumor biologically equivalent dose (BED) under dose constraints for multiple organs-at-risk (OARs). Methods: Spatiotemporal optimization was applied to a variety of lung tumors in a phantom geometry using a range of tumor sizes and locations. The optimal fractionation schedule for a patient using the linear-quadratic cell survival model depends on the tumor and OAR sensitivity to fraction size (α/β), the effective tumor doubling time (T{sub d}), and the size and location of tumormore » target relative to one or more OARs (dose distribution). The authors used a spatiotemporal optimization method to identify the optimal number of fractions N that maximizes the 3D tumor BED distribution for 16 lung phantom cases. The selection of the optimal fractionation schedule used equivalent (30-fraction) OAR constraints for the heart (D{sub mean} ≤ 45 Gy), lungs (D{sub mean} ≤ 20 Gy), cord (D{sub max} ≤ 45 Gy), esophagus (D{sub max} ≤ 63 Gy), and unspecified tissues (D{sub 05} ≤ 60 Gy). To assess plan quality, the authors compared the minimum, mean, maximum, and D{sub 95} of tumor BED, as well as the equivalent uniform dose (EUD) for optimized plans to conventional intensity-modulated radiation therapy plans prescribing 60 Gy in 30 fractions. A sensitivity analysis was performed to assess the effects of T{sub d} (3–100 days), tumor lag-time (T{sub k} = 0–10 days), and the size of tumors on optimal fractionation schedule. Results: Using an α/β ratio of 10 Gy, the average values of tumor max, min, mean BED, and D{sub 95} were up to 19%, 21%, 20%, and 19% larger than those from conventional prescription, depending on T{sub d} and T{sub k} used. Tumor EUD was up to 17% larger than the conventional prescription. For fast proliferating tumors with T{sub d} less than 10 days, there was no significant increase in tumor BED but the treatment course could be shortened without a loss in tumor BED. The improvement in the tumor mean BED was more pronounced with smaller tumors (p-value = 0.08). Conclusions: Spatiotemporal optimization of patient plans has the potential to significantly improve local tumor control (larger BED/EUD) of patients with a favorable geometry, such as smaller tumors with larger distances between the tumor target and nearby OAR. In patients with a less favorable geometry and for fast growing tumors, plans optimized using spatiotemporal optimization and conventional (spatial-only) optimization are equivalent (negligible differences in tumor BED/EUD). However, spatiotemporal optimization yields shorter treatment courses than conventional spatial-only optimization. Personalized, spatiotemporal optimization of treatment schedules can increase patient convenience and help with the efficient allocation of clinical resources. Spatiotemporal optimization can also help identify a subset of patients that might benefit from nonconventional (large dose per fraction) treatments that are ineligible for the current practice of stereotactic body radiation therapy.« less
Contemporary Statewide Practice Pattern Assessment of the Palliative Treatment of Bone Metastasis.
Spratt, Daniel E; Mancini, Brandon R; Hayman, James A; Boike, Thomas; Pierce, Lori J; Moran, Jean M; Dominello, Michael M; Fireman, Mark; Griffith, Kent; Jolly, Shruti
2018-06-01
Palliative radiation therapy for bone metastases is often viewed as a single entity, despite national guidelines providing input principally only for painful uncomplicated bone metastases. Data surrounding the treatment of bone metastases are often gleaned from questionnaires of what providers would theoretically do in practice or from population-based data lacking critical granular information. We investigated the real-world treatment of bone metastases with radiation therapy. Twenty diverse institutions across the state of Michigan had data extracted for their 10 most recent cases of radiation therapy delivered for the treatment of bone metastases at their institution between January and February 2017. Uni- and multivariable binary logistic regression was used to assess the use of single fraction (8 Gy × 1) radiation therapy. A total of 196 cases were eligible for inclusion. Twenty-eight different fractionation schedules were identified. The most common schedule was 3 Gy × 10 fractions (n = 100; 51.0%), 4 Gy × 5 fractions (n = 32; 16.3%), and 8 Gy × 1 (n = 15; 7.7%). The significant predictors for the use of single fraction radiation therapy were the presence of oligometastatic disease (P = .008), previous overlapping radiation therapy (P = .050), and academic practice type (P = .039). Twenty-nine cases (14.8%) received >10 fractions (median 15, range 11-20). Intensity modulated radiation therapy was used in 14 cases (7.1%), stereotactic body radiation therapy in 11 (5.6%), and image guidance with cone beam computed tomography in 11 (5.6%). Of the cases of simple painful bone metastases (no previous surgery, spinal cord compression, fracture, soft tissue extension, or overlapping previous radiation therapy; n = 70), only 12.9% were treated with 8 Gy × 1. Bone metastases represent a heterogeneous disease, and radiation therapy for bone metastases is similarly diverse. Future work is needed to understand the barriers to single fraction use, and clinical trials are necessary to establish appropriate guidelines for the breadth of this complex disease. Copyright © 2018 Elsevier Inc. All rights reserved.
RATIONALE: Acupuncture may help relieve dry mouth caused by radiation therapy. PURPOSE: This randomized phase III trial is studying to see how well one set of acupuncture points work in comparison to a different set of acupuncture points or standard therapy in treating dry mouth caused by radiation therapy in patients with head and neck cancer. |
[Diagnostic imaging of urolithiais. Current recommendations and new developments].
Thalgott, M; Kurtz, F; Gschwend, J E; Straub, M
2015-07-01
Prevalence of urolithiasis is increasing in industrialized countries--in both adults and children, representing a unique diagnostic and therapeutic challenge. Risk-adapted diagnostic imaging currently means assessment with maximized sensitivity and specificity together with minimal radiation exposure. In clinical routine, imaging is performed by sonography, unenhanced computed tomography (NCCT) or intravenous urography (IVU) as well as plain kidney-ureter-bladder (KUB) radiographs. The aim of the present review is a critical guideline-based and therapy-aligned presentation of diagnostic imaging procedures for optimized treatment of urolithiasis considering the specifics in children and pregnant women.
Prostate Dose Escalation by Innovative Inverse Planning-Driven IMRT
2006-11-01
fLJ and at each step, we find the minimizer u,\\ of J’. The Euler-Lagrange equation for the regularized J’ functional is u- div ( 1 Vu )= f E S1,2A...GD, Agazaryan N, Solberg TD . 2003. The effects of tumor motion on planning and delivery of respiratory-gated IMRT. Med Phys 30:1052-1066. Jaffray DA...modulated) radiation therapy: a review. Phys Med Biol 51 :R403-425. Wink NM, McNitt-Gray MF, Solberg TD . 2005. Optimization of multi-slice helical
Robot-assisted radiofrequency ablation of a sacral S1-S2 aggressive hemangioma.
Kaoudi, A; Capel, C; Chenin, L; Peltier, J; Lefranc, M
2018-05-16
Aggressive vertebral hemangiomas are rare tumors of the spine. The treatment management strategy usually consists of vertebroplasty, radiation therapy or in rare cases of surgical strategy. We present a case of a bulging sacral S1-S2 hemangioma in the spinal canal that could not be managed in the usual manner. Here, we demonstrate the usefulness of radiofrequency ablation technique as an alternative treatment as well as robotic assistance for optimal placement of the ablation probe within the lesion. Copyright © 2018. Published by Elsevier Inc.
Chen, Allen M; Farwell, D Gregory; Lau, Derick H; Li, Bao-Qing; Luu, Quang; Donald, Paul J
2011-10-01
To determine how the addition of cisplatin-based concurrent chemotherapy to radiation therapy influences outcomes among a cohort of patients treated for head-and-neck cancer of unknown primary origin. The medical records of 60 consecutive patients treated by radiation therapy for squamous cell carcinoma of the head and neck presenting as cervical lymph node metastasis of occult primary origin were reviewed. Thirty-two patients (53%) were treated by concurrent chemoradiation, and 28 patients (47%) were treated by radiation therapy alone. Forty-five patients (75%) received radiation therapy after surgical resection, and 15 patients (25%) received primary radiation therapy. Thirty-five patients (58%) were treated by intensity-modulated radiotherapy. The 2-year estimates of overall survival, local-regional control, and progression-free survival were 89%, 89%, and 79%, respectively, among patients treated by chemoradiation, compared to 90%, 92%, and 83%, respectively, among patients treated by radiation therapy alone (p > 0.05, for all). Exploratory analysis failed to identify any subset of patients who benefited from the addition of concurrent chemotherapy to radiation therapy. The use of concurrent chemotherapy was associated with a significantly increased incidence of Grade 3+ acute and late toxicity (p < 0.001, for both). Concurrent chemoradiation is associated with significant toxicity without a clear advantage to overall survival, local-regional control, and progression-free survival in the treatment of head-and-neck cancer of unknown primary origin. Although selection bias cannot be ignored, prospective data are needed to further address this question. Copyright © 2011 Elsevier Inc. All rights reserved.
Vogel, J; Lin, L; Litzky, L A; Berman, A T; Simone, C B
2017-10-01
Thymic malignancies are the most common tumors of the anterior mediastinum. The benefit of adjuvant radiation therapy for stage II disease remains controversial, and patients treated with adjuvant radiation therapy are at risk of late complications, including radiation-induced secondary malignant neoplasms (SMNs), that may reduce the overall benefit of treatment. We assess the risk of predicted SMNs following adjuvant proton radiation therapy compared with photon radiation therapy after resection of stage II thymic malignancies to determine whether proton therapy improves the risk-benefit ratio. Ten consecutive patients treated with double-scattered proton beam radiation therapy (DS-PBT) were prospectively enrolled in an institutional review board-approved proton registry study. All patients were treated with DS-PBT. Intensity modulated radiation therapy (IMRT) plans for comparison were generated. SMN risk was calculated based on organ equivalent dose. Patients had a median age of 65 years (range, 25-77 years), and 60% were men. All patients had stage II disease, and many had close or positive margins (60%). The median dose was 50.4 Gy (range, 50.4-54.0 Gy) in 1.8-Gy relative biological effectiveness daily fractions. No differences in target coverage were seen with DS-PBT compared with IMRT plans. Significant reductions were seen in mean and volumetric lung, heart, and esophageal doses with DS-PBT compared with IMRT plans (all P≤.01). Significant reductions in SMNs in the lung, breast, esophagus, skin, and stomach were seen with DS-PBT compared with IMRT. For patients with thymoma diagnosed at the median national age, 5 excess secondary malignancies per 100 patients would be avoided by treating them with protons instead of photons. Treatment with proton therapy can achieve comparable target coverage but significantly reduced doses to critical normal structures, which can lead to fewer predicted SMNs compared with IMRT. By decreasing expected late complications, proton therapy may improve the therapeutic ratio of adjuvant radiation therapy for patients with stage II thymic malignancies. Copyright © 2017 Elsevier Inc. All rights reserved.
21 CFR 892.5900 - X-ray radiation therapy system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false X-ray radiation therapy system. 892.5900 Section 892.5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-rays used for radiation therapy. This generic type of device may include signal analysis and display...
21 CFR 892.5900 - X-ray radiation therapy system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false X-ray radiation therapy system. 892.5900 Section 892.5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-rays used for radiation therapy. This generic type of device may include signal analysis and display...
21 CFR 892.5900 - X-ray radiation therapy system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false X-ray radiation therapy system. 892.5900 Section 892.5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-rays used for radiation therapy. This generic type of device may include signal analysis and display...
21 CFR 892.5900 - X-ray radiation therapy system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false X-ray radiation therapy system. 892.5900 Section 892.5900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-rays used for radiation therapy. This generic type of device may include signal analysis and display...