Sample records for radioactive tracers

  1. Comparison of the radioactive and modified techniques for measurement of stream reaeration coefficients

    USGS Publications Warehouse

    Rathbun, R.E.; Grant, R. Stephen

    1978-01-01

    There are advantages and disadvantages to both the radioactive and modified tracer techniques. The main advantage of the radioactive technique is that the tracer gas is chemically inert; the main disadvantage is that a radioactive isotope of the gas must be used to obtain the necessary analytical sensitivity. The main advantage of the modified technique is that radioactive tracers are not necessary; the main disadvantage is that the hydrocarbon tracer gases may be subject to biological degradation and sorption losses. Results of this comparison study suggest that the modified technique is a promising alternative to the use of radioactive tracers.

  2. Waste Oil Burn-Off in Coast Guard Power Plants - Diesel Piston Ring Wear Study by Radioactive Tracer Techniques

    DOT National Transportation Integrated Search

    1976-07-01

    This report covers the results of a study utilizing a radioactive tracer technique to determine wear effects on the upper compression rings of a two-stroke cycle diesel engine burning mixtures of waste lube oil in fuel oil. The radioactive tracer tec...

  3. 10 CFR 39.1 - Purpose and scope.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... of licensed materials including sealed sources, radioactive tracers, radioactive markers, and uranium... authorizing the use of licensed material in tracer studies involving multiple wells, such as field flooding...

  4. 10 CFR 39.1 - Purpose and scope.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... of licensed materials including sealed sources, radioactive tracers, radioactive markers, and uranium... authorizing the use of licensed material in tracer studies involving multiple wells, such as field flooding...

  5. 10 CFR 39.1 - Purpose and scope.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of licensed materials including sealed sources, radioactive tracers, radioactive markers, and uranium... authorizing the use of licensed material in tracer studies involving multiple wells, such as field flooding...

  6. 10 CFR 39.1 - Purpose and scope.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... of licensed materials including sealed sources, radioactive tracers, radioactive markers, and uranium... authorizing the use of licensed material in tracer studies involving multiple wells, such as field flooding...

  7. 10 CFR 39.1 - Purpose and scope.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of licensed materials including sealed sources, radioactive tracers, radioactive markers, and uranium... authorizing the use of licensed material in tracer studies involving multiple wells, such as field flooding...

  8. Predictors of sentinel lymph node metastases in breast cancer-radioactivity and Ki-67.

    PubMed

    Thangarajah, Fabinshy; Malter, Wolfram; Hamacher, Stefanie; Schmidt, Matthias; Krämer, Stefan; Mallmann, Peter; Kirn, Verena

    2016-12-01

    Since the introduction of the sentinel node technique for breast cancer in the 1990s patient's morbidity was reduced. Tracer uptake is known to be dependent from lymph node integrity and activity of macrophages. The aim of this study was to assess whether radioactivity of the tracer can predict sentinel lymph node metastases. Furthermore, a potential association with Ki-67 index was examined. Non-invasive prediction of lymph node metastases could lead to a further decrease of morbidity. We retrospectively analyzed patients with primary breast cancer who underwent surgery at the Department of Obstetrics and Gynecology in the University Hospital of Cologne between 2012 and 2013. Injection of radioactive tracer was done a day before surgery in the department of Nuclear Medicine. Clinical data and radioactivity of the sentinel node measured the day before and intraoperatively were abstracted from patient's files. Of 246 patients, 64 patients had at least one, five patients had two and one patient had three positive sentinel lymph nodes. Occurrence of sentinel lymph node metastases was not associated with preoperative tracer activity (p = 0,319), intraoperative tracer activity of first sentinel node (p = 0,086) or with loss of tracer activity until operation (p = 0,909). There was no correlation between preoperative Ki-67 index and occurrence of lymph node metastases (p = 0,403). In our cohort, there was no correlation between radioactivity and sentinel node metastases. Tracer uptake might not only be influenced by lymph node metastases and does not predict metastatic lymph node involvement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. A semi-Lagrangian advection scheme for radioactive tracers in a regional spectral model

    NASA Astrophysics Data System (ADS)

    Chang, E.-C.; Yoshimura, K.

    2015-06-01

    In this study, the non-iteration dimensional-split semi-Lagrangian (NDSL) advection scheme is applied to the National Centers for Environmental Prediction (NCEP) regional spectral model (RSM) to alleviate the Gibbs phenomenon. The Gibbs phenomenon is a problem wherein negative values of positive-definite quantities (e.g., moisture and tracers) are generated by the spectral space transformation in a spectral model system. To solve this problem, the spectral prognostic specific humidity and radioactive tracer advection scheme is replaced by the NDSL advection scheme, which considers advection of tracers in a grid system without spectral space transformations. A regional version of the NDSL is developed in this study and is applied to the RSM. Idealized experiments show that the regional version of the NDSL is successful. The model runs for an actual case study suggest that the NDSL can successfully advect radioactive tracers (iodine-131 and cesium-137) without noise from the Gibbs phenomenon. The NDSL can also remove negative specific humidity values produced in spectral calculations without losing detailed features.

  10. Gallbladder radionuclide scan (image)

    MedlinePlus

    ... gallbladder radionuclide scan is performed by injecting a tracer (radioactive chemical) into the bloodstream. A gamma camera ... detect the gamma rays being emitted from the tracer, and the image of where the tracer is ...

  11. Determination of stream reaeration coefficients by use of tracers

    USGS Publications Warehouse

    Kilpatrick, F.A.; Rathbun, R.E.; Yotsukura, N.; Parker, G.W.; DeLong, L.L.

    1987-01-01

    Stream reaeration is the physical absorption of oxygen from the atmosphere by a flowing stream. This is the primary process by which a stream replenishes the oxygen consumed in the biodegradation of organic wastes.Prior to 1965, reaeration rate coefficients could be estimated only by indirect methods. In 1965, a direct method of measuring stream reaeration coefficients was developed in which a radioactive tracer gas was injected into a stream--the tracer gas being desorbed from the stream inversely to how oxygen would be absorbed. The technique has since been modified by substituting hydrocarbon gases for the radioactive tracer gas.This manual describes the slug-injection and constant-rate injection methods of performing gas-tracer desorption measurements. Emphasis is on the use of rhodamine WT dye as a relatively conservative tracer and propane as the nonconservative gas tracer, on planning field tests, methods of injection, sampling and analysis, and computational techniques to compute desorption and reaeration coefficients.

  12. Optimization of 18 F-syntheses using 19 F-reagents at tracer-level concentrations and liquid chromatography/tandem mass spectrometry analysis: Improved synthesis of [18 F]MDL100907.

    PubMed

    Zhang, Xiang; Dunlow, Ryan; Blackman, Burchelle N; Swenson, Rolf E

    2018-05-15

    Traditional radiosynthetic optimization faces the challenges of high radiation exposure, cost, and inability to perform serial reactions due to tracer decay. To accelerate tracer development, we have developed a strategy to simulate radioactive 18 F-syntheses by using tracer-level (nanomolar) non-radioactive 19 F-reagents and LC-MS/MS analysis. The methodology was validated with fallypride synthesis under tracer-level 19 F-conditions, which showed reproducible and comparable results with radiosynthesis, and proved the feasibility of this process. Using this approach, the synthesis of [ 18 F]MDL100907 was optimized under 19 F-conditions with greatly improved yield. The best conditions were successfully transferred to radiosynthesis. A radiochemical yield of 19% to 22% was achieved with the radiochemical purity >99% and the molar activity 38.8 to 53.6 GBq/ μmol (n = 3). The tracer-level 19 F-approach provides a high-throughput and cost-effective process to optimize radiosynthesis with reduced radiation exposure. This new method allows medicinal and synthetic chemists to optimize radiolabeling conditions without the need to use radioactivity. Copyright © 2018 John Wiley & Sons, Ltd.

  13. A semi-Lagrangian advection scheme for radioactive tracers in the NCEP Regional Spectral Model (RSM)

    NASA Astrophysics Data System (ADS)

    Chang, E.-C.; Yoshimura, K.

    2015-10-01

    In this study, the non-iteration dimensional-split semi-Lagrangian (NDSL) advection scheme is applied to the National Centers for Environmental Prediction (NCEP) Regional Spectral Model (RSM) to alleviate the Gibbs phenomenon. The Gibbs phenomenon is a problem wherein negative values of positive-definite quantities (e.g., moisture and tracers) are generated by the spectral space transformation in a spectral model system. To solve this problem, the spectral prognostic specific humidity and radioactive tracer advection scheme is replaced by the NDSL advection scheme, which considers advection of tracers in a grid system without spectral space transformations. A regional version of the NDSL is developed in this study and is applied to the RSM. Idealized experiments show that the regional version of the NDSL is successful. The model runs for an actual case study suggest that the NDSL can successfully advect radioactive tracers (iodine-131 and cesium-137) without noise from the Gibbs phenomenon. The NDSL can also remove negative specific humidity values produced in spectral calculations without losing detailed features.

  14. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy....45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive tracer material to use protective gloves and, if required by the license, other protective clothing and...

  15. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy....45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive tracer material to use protective gloves and, if required by the license, other protective clothing and...

  16. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy....45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive tracer material to use protective gloves and, if required by the license, other protective clothing and...

  17. Determination of stream reaeration coefficients by use of tracers

    USGS Publications Warehouse

    Kilpatrick, F.A.; Rathbun, R.E.; Yotsukura, Nobuhiro; Parker, G.W.; DeLong, L.L.

    1989-01-01

    Stream reaeration is the physical absorption of oxygen from the atmosphere by a flowing stream. This is the primary process by which a stream replenishes the oxygen consumed in the biodegradation of organic wastes. Prior to 1965, reaeration rate coefficients could be estimated only by indirect methods. In 1965, a direct method of measuring stream reaeration coefficients was developed whereby a radioactive tracer gas was injected into a stream-the principle being that the tracer gas would be desorbed from the stream inversely to how oxygen would be absorbed. The technique has since been modified by substituting hydrocarbon gases for the radioactive tracer gas. This manual describes the slug-injection and constant-rate-injection methods of measuring gas-tracer desorption. Emphasis is on the use of rhodamine WT dye as a relatively conservative tracer and propane as the nonconservative gas tracer, on planning field tests, on methods of injection, sampling, and analysis, and on techniques for computing desorption and reaeration coefficients.

  18. The method of radioactive tracer for measuring the amount of inorganic nanoparticles in biological samples

    NASA Astrophysics Data System (ADS)

    Buzulukov, Yu; Antsiferova, A.; Demin, V. A.; Demin, V. F.; Kashkarov, P.

    2015-11-01

    The method to measure the mass of inorganic nanoparticles in biological (or any other samples) using nanoparticles labeled with radioactive tracers is developed and applied to practice. The tracers are produced in original nanoparticles by radioactive activation of some of their atomic nuclei. The method of radioactive tracers demonstrates a sensitivity, specificity and accuracy equal or better than popular methods of optical and mass spectrometry, or electron microscopy and has some specific advantages. The method can be used for study of absorption, distribution, metabolism and excretion in living organism, as well as in ecological and fundamental research. It was used in practice to study absorption, distribution, metabolism and excretion of nanoparticles of Ag, Au, Se, ZnO, TiO2 as well as to study transportation of silver nanoparticles through the barriers of blood-brain, placenta and milk gland of rats. Brief descriptions of data obtained in experiments with application of this method included in the article. The method was certified in Russian Federation standard system GOST-R and recommended by the Russian Federation regulation authority ROSPOTREBNADZOR for measuring of toxicokinetic and organotropy parameters of nanoparticles.

  19. AIR INFILTRATION MEASUREMENTS USING TRACER GASES: A LITERATURE REVIEW

    EPA Science Inventory

    The report gives results of a literature review of air filtration measurements using tracer gases, including sulfur hexafluoride, hydrogen, carbon monoxide, carbon dioxide, nitrous oxide, and radioactive argon and krypton. Sulfur hexafluoride is the commonest tracer gas of choice...

  20. Radio-tracer techniques for the study of flow in saturated porous materials

    USGS Publications Warehouse

    Skibitzke, H.E.; Chapman, H.T.; Robinson, G.M.; McCullough, Richard A.

    1961-01-01

    An experiment was conducted by the U.S. Geological Survey to determine the feasibility of using a radioactive substance as a tracer in the study of microscopic flow in a saturated porous solid. A radioactive tracer was chosen in preference to dye or other chemical in order to eliminate effects of the tracer itself on the flow system such as those relating to density, viscosity and surface tension. The porous solid was artificial "sandstone" composed of uniform fine grains of sand bonded together with an epoxy adhesive. The sides of the block thus made were sealed with an epoxy coating compound to insure water-tightness. Because of the chemical inertness of the block it was possible to use radioactive phosphorus (P32). Ion-exchange equilibrium was created between the block and nonradioactive phosphoric acid. Then a tracer tagged with P32 was injected into the block in the desired geometric configuration, in this case, a line source. After equilibrium in isotopic exchange was reached between the block and the line source, the block was rinsed, drained and sawn into slices. It was found that a quantitative analysis of the flow system may be made by assaying the dissected block. ?? 1961.

  1. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Equipment § 39.45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive...

  2. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Equipment § 39.45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive...

  3. Preparation and quantification of radioactive particles for tracking hydrodynamic behavior in multiphase reactors.

    PubMed

    Yunos, Mohd Amirul Syafiq Mohd; Hussain, Siti Aslina; Yusoff, Hamdan Mohamed; Abdullah, Jaafar

    2014-09-01

    Radioactive particle tracking (RPT) has emerged as a promising and versatile technique that can provide rich information about a variety of multiphase flow systems. However, RPT is not an off-the-shelf technique, and thus, users must customize RPT for their applications. This paper presents a simple procedure for preparing radioactive tracer particles created via irradiation with neutrons from the TRIGA Mark II research reactor. The present study focuses on the performance evaluation of encapsulated gold and scandium particles for applications as individual radioactive tracer particles using qualitative and quantitative neutron activation analysis (NAA) and an X-ray microcomputed tomography (X-ray Micro-CT) scanner installed at the Malaysian Nuclear Agency. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Measurement of the reaeration coefficients of the North Fork Licking River at Utica, Ohio by radioactive tracers

    USGS Publications Warehouse

    Hren, Janet

    1983-01-01

    Reaeration coefficients of the North Fork Licking River at Utica, Ohio were measured by the radioactive-tracer method. The tests were conducted on a 2.1-mile reach on September 23 and October 7, 1981, during low-flow conditions. Krypton-85 gas and tritium were the radioopactive tracers, which were used in conjunction with rhodamine-WT dye. The reaertion coefficients determined on September 23 were 3.09 days-1 (subreach 1-2) and 3.32 days-1 (subreach 2-3). On October 7, the values were 2.04 days -1 and 2.23 days-1 respectively.

  5. PET scan for breast cancer

    MedlinePlus

    ... radioactive substance (called a tracer) to look for breast cancer. This tracer can help identify areas of cancer ... only after a woman has been diagnosed with breast cancer. It is done to see if the cancer ...

  6. Influence of radioactivity out of the field of view on 3D PET dynamic measurement with [/sup 11/C]MP4A

    NASA Astrophysics Data System (ADS)

    Hasegawa, T.; Suzuki, M.; Murayama, H.; Irie, T.; Fukushi, K.; Wada, Y.

    1999-08-01

    This study assessed the influence of radioactivity out of the field of view (out-of-FOV) on the measurement of brain acetylcholinesterase (AChE) activity with the tracer [/sup 11/C]N-methyl-4-piperidyl-acetate by positron emission tomography in three-dimensional mode. Dynamic scans on a volunteer showed that the out-of-FOV radioactivity in the chest was much higher than that of the brain immediately after tracer injection. A representative phantom measurement was performed to quantitate the systematic errors due to the out-of-FOV radioactivity. Resultant errors in the AChE activity (k3 parameter) as calculated by compartment model analysis were found to be less than one percent in all of the brain regions studied.

  7. Patient Positioning Based on a Radioactive Tracer Implanted in Patients With Localized Prostate Cancer: A Performance and Safety Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruijf, Willy J.M. de, E-mail: kruijf.de.w@bvi.nl; Verstraete, Jan; Neustadter, David

    2013-02-01

    Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performedmore » to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.« less

  8. Patient positioning based on a radioactive tracer implanted in patients with localized prostate cancer: a performance and safety evaluation.

    PubMed

    de Kruijf, Willy J M; Verstraete, Jan; Neustadter, David; Corn, Benjamin W; Hol, Sandra; Venselaar, Jack L M; Davits, Rob J; Wijsman, Bart P; Van den Bergh, Laura; Budiharto, Tom; Oyen, Raymond; Haustermans, Karin; Poortmans, Philip M P

    2013-02-01

    To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ((192)Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Feasibility of Using Radioactive Tracers for Studies of Permeation of Chemicals through Protective Clothing Materials

    DTIC Science & Technology

    1991-10-01

    minutes, 100x and 1000x magnification. letflon Coated Nomex, Methylene chloride 15 MINm ea p D ~ecant Freda 113 10 N2 70 d %~ C (gg / 󈧒 v 2 10 a. 11 56...Report No. CG- D -10-91 AD-A246 192 Feasibility of Using Radioactive Tracers for Studies of Permeation of Chemicals Through Protective Clothing...Connecticut 06340-6096 ii Technical Report Documentation Page 1. Report No. 2. Government Accession No. 3. Recipient’s Catalog No. CG- D -10-91 I 4

  10. A review of radioactive isotopes and other residence time tracers in understanding groundwater recharge: Possibilities, challenges, and limitations

    NASA Astrophysics Data System (ADS)

    Cartwright, Ian; Cendón, Dioni; Currell, Matthew; Meredith, Karina

    2017-12-01

    Documenting the location and magnitude of groundwater recharge is critical for understanding groundwater flow systems. Radioactive tracers, notably 14C, 3H, 36Cl, and the noble gases, together with other tracers whose concentrations vary over time, such as the chlorofluorocarbons or sulfur hexafluoride, are commonly used to estimate recharge rates. This review discusses some of the advantages and problems of using these tracers to estimate recharge rates. The suite of tracers allows recharge to be estimated over timescales ranging from a few years to several hundred thousand years, which allows both the long-term and modern behaviour of groundwater systems to be documented. All tracers record mean residence times and mean recharge rates rather than a specific age and date of recharge. The timescale over which recharge rates are averaged increases with the mean residence time. This is an advantage in providing representative recharge rates but presents a problem in comparing recharge rates derived from these tracers with those from other techniques, such as water table fluctuations or lysimeters. In addition to issues relating to the sampling and interpretation of specific tracers, macroscopic dispersion and mixing in groundwater flow systems limit how precisely groundwater residence times and recharge rates may be estimated. Additionally, many recharge studies have utilised existing infrastructure that may not be ideal for this purpose (e.g., wells with long screens that sample groundwater several kilometres from the recharge area). Ideal recharge studies would collect sufficient information to optimise the use of specific tracers and minimise the problems of mixing and dispersion.

  11. In vivo evaluation of radiotracers targeting the melanin-concentrating hormone receptor 1: [11C]SNAP-7941 and [18F]FE@SNAP reveal specific uptake in the ventricular system.

    PubMed

    Zeilinger, Markus; Dumanic, Monika; Pichler, Florian; Budinsky, Lubos; Wadsak, Wolfgang; Pallitsch, Katharina; Spreitzer, Helmut; Lanzenberger, Rupert; Hacker, Marcus; Mitterhauser, Markus; Philippe, Cécile

    2017-08-14

    The MCHR1 is involved in the regulation of energy homeostasis and changes of the expression are linked to a variety of associated diseases, such as diabetes and adiposity. The study aimed at the in vitro and in vivo evaluation of [ 11 C]SNAP-7941 and [ 18 F]FE@SNAP as potential PET-tracers for the MCHR1. Competitive binding studies with non-radioactive derivatives and small-animal PET/CT and MRI brain studies were performed under baseline conditions and tracer displacement with the unlabelled MCHR1 antagonist (±)-SNAP-7941. Binding studies evinced high binding affinity of the non-radioactive derivatives. Small-animal imaging of [ 11 C]SNAP-7941 and [ 18 F]FE@SNAP evinced high tracer uptake in MCHR1-rich regions of the ventricular system. Quantitative analysis depicted a significant tracer reduction after displacement with (±)-SNAP-7941. Due to the high binding affinity of the non-labelled derivatives and the high specific tracer uptake of [ 11 C]SNAP-7941 and [ 18 F]FE@SNAP, there is strong evidence that both radiotracers may serve as highly suitable agents for specific MCHR1 imaging.

  12. Environmental and Water Quality Operational Studies. Fluorometric Techniques for Tracing Reservoir Inflows.

    DTIC Science & Technology

    1984-04-01

    applicability . 4. When natural tracers have been unavailable, artificial tracers have been introduced to mark the inflow. Radioactive tracers have proved to be...day. The USGS has set even stricter standards for its field applications , limiting concentrations near water intakes to 10 ppb (Wilson 1968). 20. In a...its use (e.g., preparing impact statements based on knowledge of nitrite concentrations in the application area or limiting concentra- tions near

  13. Project Physics Handbook 6, The Nucleus.

    ERIC Educational Resources Information Center

    Harvard Univ., Cambridge, MA. Harvard Project Physics.

    Five experiments and nine activities are presented in this Unit 6 handbook. The experiments are related to random events, ranges of alpha and beta particles, half-lives, and radioactive tracers. The activities are concerned with the energy measurement in beta radiation, demonstration with sugar cubes, ionization by radioactivity, magnetic…

  14. Transdiaphragmatic transport of tracer albumin from peritoneal to pleural liquid measured in rats.

    PubMed

    Lai-Fook, Stephen J; Houtz, Pamela K; Jones, Philip D

    2005-12-01

    In conscious Wistar-Kyoto rats, we studied the uptake of radioactive tracer (125)I-albumin into the pleural space and circulation after intraperitoneal (IP) injections with 1 or 5 ml of Ringer solution (3 g/dl albumin). Postmortem, we sampled pleural liquid, peritoneal liquid, and blood plasma 2-48 h after IP injection and measured their radioactivity and protein concentration. Tracer concentration was greater in pleural liquid than in plasma approximately 3 h after injection with both IP injection volumes. This behavior indicated transport of tracer through the diaphragm into the pleural space. A dynamic analysis of the tracer uptake with 5-ml IP injections showed that at least 50% of the total pleural flow was via the diaphragm. A similar estimate was derived from an analysis of total protein concentrations. Both estimates were based on restricted pleural capillary filtration and unrestricted transdiaphragmatic transport. The 5-ml IP injections did not change plasma protein concentration but increased pleural and peritoneal protein concentrations from control values by 22 and 30%, respectively. These changes were consistent with a small (approximately 8%) increase in capillary filtration and a small (approximately 20%) reduction in transdiaphragmatic flow from control values, consistent with the small (3%) decrease in hydration measured in diaphragm muscle. Thus the pleural uptake of tracer via the diaphragm with the IP injections occurred by the near-normal transport of liquid and protein.

  15. Be-7 as a tracer for short-term soil surface changes - opportunities and limitations

    NASA Astrophysics Data System (ADS)

    Baumgart, Philipp

    2013-04-01

    Within the last 20 years the cosmogenic nuclide Beryllium-7 was successfully established as a suitable tracer element to detect soil surface changes with a high accuracy. Particularly soil erosion rates from single precipitation events are in the focus of different studies due to the short radioactive half-life of the Be-7 isotope. High sorption at topmost soil particles and immobility at given pH-values enable fine-scaled erosion modelling down to 2 mm increments. But some important challenging limitations require particular attention, starting from sampling up to the final data evaluation. E.g. these are the realisation of the fine increment soil collection, the limiting amount of measurable samples per campaign due to the short radioactive half-life and the specific requirements for the detector measurements. Both, the high potential and the challenging limitations are presented as well as future perspectives of that tracer method.

  16. Oribatid mites and nutrient cycling. [Nutrient release by decomposition of leaf litter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crossley, D.A. Jr.

    1976-08-01

    Communities of oribatid mites (Cryptostigmata) in leaf litter and forest soils consist of an impressive number of individuals. Total populations of the order of 10/sup 5/ oribatids per square meter are commonly reported from forest floors. Because of their numbers, oribatids have been believed to be important contributors to the breakdown of organic detritus. Results are reported from studies of mineral or nutrient element cycling in forest floor ecosystems using radioisotopes as tracers. The phenomenon of cycling allows for the study of feedback loops among ecosystem processes, whereas energy flow is unidirectional. Evaluation of feedback loops can be a meansmore » of quantifying indirect effects of consumers. The availability of radioactive isotopes or radioactive analogs of mineral elements allows for the direct measurement of transfer rates. In decomposition studies applications of radioactive tracers have helped to identify pathways of transfer from microflora to oribatids.« less

  17. Preclinical validation of 111In-girentuximab-F(ab')2 as a tracer to image hypoxia related marker CAIX expression in head and neck cancer xenografts.

    PubMed

    Huizing, Fokko J; Hoeben, Bianca A W; Franssen, Gerben; Lok, Jasper; Heskamp, Sandra; Oosterwijk, Egbert; Boerman, Otto C; Bussink, Johan

    2017-09-01

    Hypoxia is a major cause of radio- and chemoresistance. Carbonic anhydrase IX (CAIX) is an endogenous hypoxia-related marker and an important prognostic marker. Assessment of CAIX expression may allow patient selection for hypoxia or CAIX-targeted treatment. The radioactive tracer 111 In-girentuximab-F(ab') 2 targets CAIX and can be used for SPECT imaging. Aim of this study was to validate and optimize 111 In-girentuximab-F(ab') 2 for imaging of CAIX expression in head and neck tumor xenografts. Affinity and internalization kinetics of 111 In-girentuximab-F(ab') 2 were determined in vitro using CAIX-expressing SK-RC-52 cells. Tumor targeting characteristics were determined in athymic mice with six different head and neck squamous cell carcinoma (SCCNij) xenografts. Tracer uptake was measured by ex vivo radioactivity counting. Intratumoral distribution of tracer uptake was measured using autoradiography and CAIX expression was determined immunohistochemically. 26% of the tracer was internalized into the SK-RC-52 cells within 24h. The half maximal inhibitory concentration (IC 50 ) was 0.69±0.08nM. In biodistribution studies SCCNij153 tumors showed the highest tracer uptake: 4.1±0.8ID/g at 24h p.i. Immunohistochemical and autoradiographic analyses of the xenografts showed a distinct spatial correlation between localization of the tracer and CAIX expression. 111 In-girentuximab-F(ab') 2 has a high affinity for CAIX. In vivo tumor uptake correlated strongly with CAIX expression in different head and neck xenografts. These results suggest that 111 In-girentuximab-F(ab') 2 is a promising tracer for imaging of hypoxia-related CAIX expression. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Apparatus and method for downhole injection of radioactive tracer

    DOEpatents

    Potter, R.M.; Archuleta, J.; Fink, C.F.

    The disclosure relates to downhole injection of radioactive /sup 82/Br and monitoring its progress through fractured structure to determine the nature thereof. An ampule containing granular /sup 82/Br is remotely crushed and water is repeatedly flushed through it to cleanse the instrument as well as inject the /sup 82/Br into surrounding fractured strata. A sensor in a remote horehole reads progress of the radioactive material through fractured structure.

  19. Apparatus and method for downhole injection of radioactive tracer

    DOEpatents

    Potter, Robert M.; Archuleta, Jacobo R.; Fink, Conrad F.

    1983-01-01

    The disclosure relates to downhole injection of radioactive .sup.82 Br and monitoring its progress through fractured structure to determine the nature thereof. An ampule containing granular .sup.82 Br is remotely crushed and water is repeatedly flushed through it to cleanse the instrument as well as inject the .sup.82 Br into surrounding fractured strata. A sensor in a remote borehole reads progress of the radioactive material through fractured structure.

  20. UNESCO Chemistry Teaching Project in Asia: Experiments on Nuclear Science.

    ERIC Educational Resources Information Center

    Dhabanandana, Salag

    This teacher's guide on nuclear science is divided into two parts. The first part is a discussion of some of the concepts in nuclear chemistry including radioactivity, types of disintegration, radioactive decay and growth, and tracer techniques. The relevant experiments involving the use of radioisotopes are presented in the second part. The…

  1. Feasibility of Real-Time Near-Infrared Fluorescence Tracer Imaging in Sentinel Node Biopsy for Oral Cavity Cancer Patients.

    PubMed

    Christensen, Anders; Juhl, Karina; Charabi, Birgitte; Mortensen, Jann; Kiss, Katalin; Kjær, Andreas; von Buchwald, Christian

    2016-02-01

    Sentinel node biopsy (SNB) is an established method in oral squamous cell carcinoma (OSCC) for staging the cN0 neck and to select patients who will benefit from a neck dissection. Near-infrared fluorescence (NIRF) imaging has the potential to improve the SNB procedure by facilitating intraoperative visual identification of the sentinel lymph node (SN). The purpose of this study was to evaluate the feasibility of fluorescence tracer imaging for SN detection in conjunction with conventional radio-guided technique. Prospective study of patients with primary OSCC planned for tumor resection and SNB. Thirty patients were injected peritumorally with a bimodal tracer (ICG-99mTc-Nanocoll) followed by lymphoscintigraphy and SPECT/CT to define the SNs and their anatomic allocation preoperatively. SNs were detected intraoperatively with a hand-held gamma-probe and a hand-held NIRF camera. In 29 of 30 subjects (97%), all preoperatively defined SNs could be identified intraoperatively using a combination of radioactive and fluorescence guidance. A total of 94 SNs (mean 3, range 1-5) that were both radioactive and fluorescent ex vivo were harvested. Eleven of 94 SNs (12%) could only be identified in vivo using NIRF imaging, and the majority of those were located in level 1 close to the primary tumor. A combined fluorescent and radioactive tracer for SNB is feasible, and the additional use of NIRF imaging may improve the accuracy of SN identification in oral cancer patients. Intraoperative fluorescence guidance seems of particular value when SNs are located in close proximity to the injection site.

  2. PET Imaging: Basics and New Trends

    NASA Astrophysics Data System (ADS)

    Dahlbom, Magnus

    Positron Emission Tomography or PET is a noninvasive molecular imaging method used both in research to study biology and disease, and clinically as a routine diagnostic imaging tool. In PET imaging, the subject is injected with a tracer labeled with a positron-emitting isotope and is then placed in a scanner to localize the radioactive tracer in the body. The localization of the tracer utilizes the unique decay characteristics of isotopes decaying by positron emission. In the PET scanner, a large number of scintillation detectors use coincidence detection of the annihilation radiation that is emitted as a result of the positron decay. By collecting a large number of these coincidence events, together with tomographic image reconstruction methods, the 3-D distribution of the radioactive tracer in the body can be reconstructed. Depending on the type of tracer used, the distribution will reflect a particular biological process, such as glucose metabolism when fluoro-deoxyglucose is used. PET has evolved from a relatively inefficient single-slice imaging system with relatively poor spatial resolution to an efficient, high-resolution imaging modality which can acquire a whole-body scan in a few minutes. This chapter will describe the basic physics and instrumentation used in PET. The various corrections that are necessary to apply to the acquired data in order to produce quantitative images are also described. Finally, some of the latest trends in instrumentation development are also discussed.

  3. Hybrid dynamic radioactive particle tracking (RPT) calibration technique for multiphase flow systems

    NASA Astrophysics Data System (ADS)

    Khane, Vaibhav; Al-Dahhan, Muthanna H.

    2017-04-01

    The radioactive particle tracking (RPT) technique has been utilized to measure three-dimensional hydrodynamic parameters for multiphase flow systems. An analytical solution to the inverse problem of the RPT technique, i.e. finding the instantaneous tracer positions based upon instantaneous counts received in the detectors, is not possible. Therefore, a calibration to obtain a counts-distance map is needed. There are major shortcomings in the conventional RPT calibration method due to which it has limited applicability in practical applications. In this work, the design and development of a novel dynamic RPT calibration technique are carried out to overcome the shortcomings of the conventional RPT calibration method. The dynamic RPT calibration technique has been implemented around a test reactor with 1foot in diameter and 1 foot in height using Cobalt-60 as an isotopes tracer particle. Two sets of experiments have been carried out to test the capability of novel dynamic RPT calibration. In the first set of experiments, a manual calibration apparatus has been used to hold a tracer particle at known static locations. In the second set of experiments, the tracer particle was moved vertically downwards along a straight line path in a controlled manner. The obtained reconstruction results about the tracer particle position were compared with the actual known position and the reconstruction errors were estimated. The obtained results revealed that the dynamic RPT calibration technique is capable of identifying tracer particle positions with a reconstruction error between 1 to 5.9 mm for the conditions studied which could be improved depending on various factors outlined here.

  4. Tracking different freshwater plumes at the Bay of Biscay scale by using a dissolved radioactive tracer: tritium (HTO)

    NASA Astrophysics Data System (ADS)

    Oms, Pierre-Emmanuel; Bailly du Bois, Pascal; Dumas, Franck; Lazure, Pascal; Morillon, Mehdi; Solier, Luc; Voiseux, Claire; Le Corre, Cédric; Maire, Donovan

    2017-04-01

    New measurements of a radioactive tracer (tritium) on the whole continental shelf of the Bay of Biscay during several oceanographic campaigns between 2008 and 2016 allow comparison with results of the plume dispersion from the regional circulation model, MARS3D (Lazure and Dumas, 2008). Seaward dispersion of freshwater in the Bay of Biscay is highly variable in time and depends on many processes like tide, wind, freshwater runoff or water mass stratification. Until now salinity was a useful tracer to describe dispersion of freshwater, but the complexity to account for these different sources require an additional conservative tracer. Tritium (3H) is a radionuclide tracer released as HTO in the Bay of Biscay by nuclear power plant through two French rivers, Loire and Gironde. Tritium inflow from Loire and Gironde are well known thanks to plants operator data and an effort of daily measurements. Indeed an automated and daily integrated sampling system is deployed in the Loire River and the Gironde Estuary. These plumes are clearly detectable over the continental shelf despite very low tritium concentrations (0.05 - 0.5 Bq/L, 0.5 - 5 TU). In order to determine such low tritium concentrations in the Bay of Biscay, we use a mass spectrometer to measure the 3He (gas) produced by radioactive disintegration of tritium after 3He ingrowth (1 - 6 months). The aim of this work is to describes and quantify the dispersion processes occurring in the continental shelf according to seasons. Thanks to assessments of the model dispersion compared to in-situ measurements, quantification of the residential time of freshwater in the continental shelf as well as quantification of their transfer from continental shelf to abyssal plain is possible. The 3H/S ratio will allow an estimation of respective inputs from Loire and Gironde in the bay.

  5. Tracking short-term biodistribution and long-term clearance of SPIO tracers in magnetic particle imaging

    NASA Astrophysics Data System (ADS)

    Keselman, Paul; Yu, Elaine Y.; Zhou, Xinyi Y.; Goodwill, Patrick W.; Chandrasekharan, Prashant; Ferguson, R. Matthew; Khandhar, Amit P.; Kemp, Scott J.; Krishnan, Kannan M.; Zheng, Bo; Conolly, Steven M.

    2017-05-01

    Magnetic particle imaging (MPI) is an emerging tracer-based medical imaging modality that images non-radioactive, kidney-safe superparamagnetic iron oxide (SPIO) tracers. MPI offers quantitative, high-contrast and high-SNR images, so MPI has exceptional promise for applications such as cell tracking, angiography, brain perfusion, cancer detection, traumatic brain injury and pulmonary imaging. In assessing MPI’s utility for applications mentioned above, it is important to be able to assess tracer short-term biodistribution as well as long-term clearance from the body. Here, we describe the biodistribution and clearance for two commonly used tracers in MPI: Ferucarbotran (Meito Sangyo Co., Japan) and LS-oo8 (LodeSpin Labs, Seattle, WA). We successfully demonstrate that 3D MPI is able to quantitatively assess short-term biodistribution, as well as long-term tracking and clearance of these tracers in vivo.

  6. An ELISA DYRK1A non-radioactive kinase assay suitable for the characterization of inhibitors

    PubMed Central

    Liu, Yong; Adayev, Tatyana; Hwang, Yu-Wen

    2017-01-01

    The DYRK1A (dual specificity tyrosine phosphorylation-regulated kinase 1A) gene encodes a proline-directed Ser/Thr kinase. Elevated expression and/or altered distribution of the kinase have been implicated in the neurological impairments associated with Down syndrome (DS) and Alzheimer’s disease (AD). Consequently, DYRK1A inhibition has been of significant interest as a potential strategy for therapeutic intervention of DS and AD. Many classes of novel inhibitors have been described in the past decade. Although non-radioactive methods for analyzing DYRK1A inhibition have been developed, methods employing radioactive tracers are still commonly used for quantitative characterization of DYRK1A inhibitors. Here, we present a non-radioactive ELISA assay based on the detection of DYRK1A-phosphorylated dynamin 1a fragment using a phosphorylation site-specific antibody. The assay was verified by the use of two well-characterized DYRK1A inhibitors, epigallocatechin gallate (EGCG) and harmine. The IC 50s for EGCG and harmine determined by the ELISA method were found to be comparable to those previously measured by radioactive tracing methods.  Furthermore, we determined the mode of inhibition for EGCG and harmine by a modification of the ELISA assay. This assay confirms the mode of inhibition of EGCG (non-ATP-competitive) and harmine (ATP-competitive), as previously determined. We conclude that the ELISA platform demonstrated here is a viable alternative to the traditional radioactive tracer assays for analyzing DYRK1A inhibitors. PMID:28163906

  7. LOW LEVEL LOW ENERGY LOW QUANTITY SAMPLE COUNTING IN TRACER WORK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosain, F.

    1958-01-01

    A gas-flow Geiger counter has been set in anticoincidence with a ring of 10 Geiger-Mueller cosmic-ray counters and the whole assembly placed inside an iron castle. Radioactive samples can be introduced directly within the structure of the counter. The apparatus has been used in very low level tracer work with S/sup 35/, Fe/sup 55/, and I/sup 131/. (J.S.R.)

  8. Hybrid model based unified scheme for endoscopic Cerenkov and radio-luminescence tomography: Simulation demonstration

    NASA Astrophysics Data System (ADS)

    Wang, Lin; Cao, Xin; Ren, Qingyun; Chen, Xueli; He, Xiaowei

    2018-05-01

    Cerenkov luminescence imaging (CLI) is an imaging method that uses an optical imaging scheme to probe a radioactive tracer. Application of CLI with clinically approved radioactive tracers has opened an opportunity for translating optical imaging from preclinical to clinical applications. Such translation was further improved by developing an endoscopic CLI system. However, two-dimensional endoscopic imaging cannot identify accurate depth and obtain quantitative information. Here, we present an imaging scheme to retrieve the depth and quantitative information from endoscopic Cerenkov luminescence tomography, which can also be applied for endoscopic radio-luminescence tomography. In the scheme, we first constructed a physical model for image collection, and then a mathematical model for characterizing the luminescent light propagation from tracer to the endoscopic detector. The mathematical model is a hybrid light transport model combined with the 3rd order simplified spherical harmonics approximation, diffusion, and radiosity equations to warrant accuracy and speed. The mathematical model integrates finite element discretization, regularization, and primal-dual interior-point optimization to retrieve the depth and the quantitative information of the tracer. A heterogeneous-geometry-based numerical simulation was used to explore the feasibility of the unified scheme, which demonstrated that it can provide a satisfactory balance between imaging accuracy and computational burden.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jahn, A.; Lindsay, K.; Giraud, X.

    Carbon isotopes in the ocean are frequently used as paleoclimate proxies and as present-day geochemical ocean tracers. In order to allow a more direct comparison of climate model results with this large and currently underutilized data set, we added a carbon isotope module to the ocean model of the Community Earth System Model (CESM), containing the cycling of the stable isotope 13C and the radioactive isotope 14C. We implemented the 14C tracer in two ways: in the "abiotic" case, the 14C tracer is only subject to air–sea gas exchange, physical transport, and radioactive decay, while in the "biotic" version, themore » 14C additionally follows the 13C tracer through all biogeochemical and ecological processes. Thus, the abiotic 14C tracer can be run without the ecosystem module, requiring significantly fewer computational resources. The carbon isotope module calculates the carbon isotopic fractionation during gas exchange, photosynthesis, and calcium carbonate formation, while any subsequent biological process such as remineralization as well as any external inputs are assumed to occur without fractionation. Given the uncertainty associated with the biological fractionation during photosynthesis, we implemented and tested three parameterizations of different complexity. Compared to present-day observations, the model is able to simulate the oceanic 14C bomb uptake and the 13C Suess effect reasonably well compared to observations and other model studies. Lastly, at the same time, the carbon isotopes reveal biases in the physical model, for example, too sluggish ventilation of the deep Pacific Ocean.« less

  10. Bone Scan

    MedlinePlus

    ... your doctor might order additional imaging called single-photon emission computerized tomography (SPECT). This imaging can help ... radioactivity from the tracers is usually completely eliminated two days after the scan. Results A doctor who ...

  11. Methods for the Measurement of a Bacterial Enzyme Activity in Cell Lysates and Extracts

    PubMed Central

    Mendz, George; Hazell, Stuart

    1998-01-01

    The kinetic characteristics and regulation of aspartate carbamoyltransferase activity were studied in lysates and cell extracts of Helicobacter pylori by three diffirent methods. Nuclear magnetic resonance spectroscopy, radioactive tracer analysis, and spectrophotometry were employed in conjunction to identify the properties of the enzyme activity and to validate the results obtained with each assay. NMR spectroscopy was the most direct method to provide proof of ACTase activity; radioactive tracer analysis was the most sensitive technique and a microtitre-based colorimetric assay was the most cost-and time-efficient for large scale analyses. Freeze-thawing was adopted as the preferred method for cell lysis in studying enzyme activity in situ. This study showed the benefits of employing several different complementary methods to investigate bacterial enzyme activity. PMID:12734591

  12. Internal corrosion monitoring of subsea oil and gas production equipment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joosten, M.W.; Fischer, K.P.; Strommen, R.

    1995-04-01

    Nonintrusive techniques will dominate subsea corrosion monitoring compared with the intrusive methods because such methods do not interfere with pipeline operations. The long-term reliability of the nonintrusive techniques in general is considered to be much better than that of intrusive-type probes. The nonintrusive techniques based on radioactive tracers (TLA, NA) and FSM and UT are expected to be the main types of subsea corrosion monitoring equipment in the coming years. Available techniques that could be developed specifically for subsea applications are: electrochemical noise, corrosion potentials (using new types of reference electrodes), multiprobe system for electrochemical measurements, and video camera inspectionmore » (mini-video camera with light source). The following innovative techniques have potential but need further development: ion selective electrodes, radioactive tracers, and Raman spectroscopy.« less

  13. Clinical trial of combined radio- and fluorescence-guided sentinel lymph node biopsy in breast cancer

    PubMed Central

    Schaafsma, Boudewijn E.; Verbeek, Floris P.R.; Rietbergen, Daphne D.D.; van der Hiel, Bernies; van der Vorst, Joost R.; Liefers, Gerrit-Jan; Frangioni, John V.; van de Velde, Cornelis J.H.; van Leeuwen, Fijs W.B.; Vahrmeijer, Alexander L.

    2013-01-01

    Background Combining radioactive colloids and a near-infrared (NIR) fluorophore permit preoperative planning and intraoperative localization of deeply located sentinel lymph nodes (SLNs) with direct optical guidance by a single lymphatic tracer. The aim of this clinical trial was to evaluate and optimize a hybrid NIR fluorescence and radioactive tracer for SLN detection in breast cancer patients. Method Patients with breast cancer undergoing SLN biopsy were enrolled. The day before surgery, indocyanine green (ICG)-99mTc-Nanocolloid was injected periareolarly and a lymphoscintigram was acquired. Directly before surgery, blue dye was injected. Intraoperative SLN localization was performed by a gamma probe and the Mini-FLARETM NIR fluorescence imaging system. Patients were divided into two dose groups, with one group receiving twice the particle density of ICG and nanocolloid, but the same dose of radioactive 99mTechnetium. Results Thirty-two patients were enrolled in the trial. At least one SLN was identified pre- and intraoperatively. All 48 axillary SLNs could be detected by gamma tracing and NIR fluorescence imaging, but only 42 of them stained blue. NIR fluorescence permitted detection of lymphatic vessels draining to the SLN up to 29 hours after injection. Increasing the particle density by two-fold did not yield a difference in fluorescence intensity, median 255 (range 98 – 542) vs. median 284 (90 – 921; P = 0.590), or signal- to- background ratio, median 5.4 (range 3.0 – 15.4) vs. median 4.9 (3.5 – 16.3; P = 1.000), of the SLN. Conclusion The hybrid NIR fluorescence and radioactive tracer ICG-99mTc-Nanocolloid permitted accurate pre- and intraoperative detection of the SLNs in patients with breast cancer. PMID:23696463

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weisenberger, Andrew G.; Kross, Brian J.; Lee, Seung Joo

    The ability to detect the emissions of radioactive isotopes through radioactive decay (e.g. beta particles, x-rays and gamma-rays) has been used for over 80 years as a tracer method for studying natural phenomena. More recently a positron emitting radioisotope of carbon: {sup 11}C has been utilized as a {sup 11}CO{sub 2} tracer for plant ecophysiology research. Because of its ease of incorporation into the plant via photosynthesis, the {sup 11}CO{sub 2} radiotracer is a powerful tool for use in plant biology research. Positron emission tomography (PET) imaging has been used to study carbon transport in live plants using {sup 11}CO{submore » 2}. Presently there are several groups developing and using new PET instrumentation for plant based studies. Thomas Jefferson National Accelerator Facility (Jefferson Lab) in collaboration with the Duke University Phytotron and the Triangle Universities Nuclear Laboratory (TUNL) is involved in PET detector development for plant imaging utilizing technologies developed for nuclear physics research. The latest developments of the use of a LYSO scintillator based PET detector system for {sup 11}CO{sub 2} tracer studies in plants will be briefly outlined.« less

  15. Groundwater studies using isotopes and noble gases as a tracer: Review and prospect

    NASA Astrophysics Data System (ADS)

    Kazahaya, Kohei; Yasuhara, Masaya; Takahashi, Hiroshi A.; Morikawa, Noritoshi; Ohwada, Michiko; Tosaki, Yuki; Asai, Kazuyoshi

    Environmental tracers become a common tool for the groundwater study and a number of methods have been presented in order to understand groundwater flow processes, water budget, origins, chemical reaction processes and retention time. Tracers often used are selected and reviewed for their various methods and advantages as follows; 1) stable 18O, D in water, 2) stable 13C and radioactive 14C in DIC, 3) noble gases such as He, Ne, Ar, Kr, Xe and their isotopes, 4) radioactive 36Cl in dissolved chloride and some heavier isotopes, and 5) inert gaseous species such as CFCs. If they are less reactive species, they likely preserve information at the time of recharge or their origin. Use of D, 18O and the d-value of water is the powerful tool to determine the recharge area because recharged meteoric water have their inherent isotopic ratios correlated with the recharge elevation, distance from the coast, or the local topography. Carbon-bearing species are more reactive though, use of stable isotopes of DIC leads to identify its origin and helps to analyze the chemical reaction between minerals and water or gas addition processes during the groundwater flow in aquifers. Radioactive 14C has been used to estimate groundwater age however special attention should be paid for, i.e., the origin of DIC, before applying the method. Noble gas tracers are the useful species to presume recharge temperature from their concentrations in water using their temperature dependence of solubilities. Radiogenic 4He concentration can be used for the very long-term groundwater dating since the 4He is produced in the crust and is accumulated in the deep aquifers, if the local accumulation rate of 4He is known. Radioactive 36Cl has been used to determine the age of very old saline waters up to million years. This isotope will also be convenient for the dating of very younger waters, by the use of bomb-produced 36Cl resulted from surface nuclear experiments near the seawater in the 1950s. Chlorofluorocarbons (CFCs) are the gas species produced by the recent human activity and dissolve in water during the recharge, therefore, the affected younger groundwater will have equivalent CFCs concentrations with the atmospheric CFCs concentrations at the time of the recharge. As these species are easy to detect with very high sensitivity, this tracer has now been applied not only for the age determination but for the mixing or contamination of shallow young water to a deep old groundwater. As an individual method listed above is valid only for the very simple flow system, appropriate assumptions or coupling of using different tracers is necessary to understand natural complex groundwater flow system where mixing of groundwaters of different origin or age occurs. Combination of tracers helps us simulating the complex system in detail and is being a growing trend in groundwater study.

  16. Radioisotopes for research on and control of mosquitos

    PubMed Central

    Bruce-Chwatt, Leonard J.

    1956-01-01

    Practical applications of radioactive isotopes in medicine, science, and industry have multiplied enormously during the past five years. In this paper, the author attempts to gather what is known about the use of radioactive isotopes in the research on malaria control. The development of the uranium pile for large-scale production of radioisotopes and technical progress in the making of reliable electronic equipment have greatly contributed to the application of radioactive tracers in biological research. The present knowledge of radioisotopes in mosquito and in insecticide research is discussed. ImagesFIG. 1 PMID:13404435

  17. Simultaneous acquisition of (99m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors.

    PubMed

    Kobayashi, Masato; Matsunari, Ichiro; Nishi, Kodai; Mizutani, Asuka; Miyazaki, Yoshiharu; Ogai, Kazuhiro; Sugama, Jyunko; Shiba, Kazuhiro; Kawai, Keiichi; Kinuya, Seigo

    2016-05-01

    Simultaneous acquisition of (99m)Tc and (123)I was evaluated using a preclinical SPECT scanner with cadmium zinc telluride (CZT)-based detectors. 10-ml cylindrical syringes contained about 37 MBq (99m)Tc-tetrofosmin ((99m)Tc-TF) or 37 MBq (123)I-15-(p-iodophenyl)-3R,S-methyl pentadecanoic acid ((123)I-BMIPP) were used to assess the relationship between these SPECT radioactive counts and radioactivity. Two 10-ml syringes contained 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP to assess the influence of (99m)Tc upscatter and (123)I downscatter, respectively. A rat-sized cylindrical phantom also contained both 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. The two 10-ml syringes and phantom were scanned using a pinhole collimator for rats. Myocardial infarction model rats were examined using 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. Two 1-ml syringes contained 105 MBq (99m)Tc-labeled hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) and 35 MBq (123)I-labeled N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl) nortropane ((123)I-FP-CIT). The two 1-ml syringes were scanned using a pinhole collimator for mice. Normal mice were examined using 105 MBq (99m)Tc-HMPAO and 35 MBq (123)I-FP-CIT. The relationship between SPECT radioactive counts and radioactivity was excellent. Downscatter contamination of (123)I-BMIPP exhibited fewer radioactive counts for 300 MBq (99m)Tc-TF without scatter correction (SC) in 125-150 keV. There was no upscatter contamination of (99m)Tc-TF in 150-175 keV. In the rat-sized phantom, the radioactive count ratio decreased to 4.0 % for 300 MBq (99m)Tc-TF without SC in 125-150 keV. In the rats, myocardial images and radioactive counts of (99m)Tc-TF with the dual tracer were identical to those of the (99m)Tc-TF single injection. Downscatter contamination of (123)I-FP-CIT was 4.2 % without SC in 125-150 keV. In the first injection of (99m)Tc-HMPAO and second injection of (123)I-FP-CIT, brain images and radioactive counts of (99m)Tc-HMPAO with the dual tracer in normal mice also were the similar to those of the (99m)Tc-HMPAO single injection. In the first injection of (123)I-FP-CIT and second injection of (99m)Tc-HMPAO, the brain images and radioactive counts with the dual tracer were not much different from those of the (123)I-FP-CIT single injection. Dual-tracer imaging of (99m)Tc- and (123)I-labeled radiotracers is feasible in a preclinical SPECT scanner with CZT detector. When higher radioactivity of (99m)Tc-labeled radiotracers relative to (123)I-labeled radiotracers is applied, correction methods are not necessarily required for the quantification of (99m)Tc- and (123)I-labeled radiotracers when using a preclinical SPECT scanner with CZT detector.

  18. Evaluation of the novel myocardial perfusion positron-emission tomography tracer 18F-BMS-747158-02: comparison to 13N-ammonia and validation with microspheres in a pig model.

    PubMed

    Nekolla, S G; Reder, S; Saraste, A; Higuchi, T; Dzewas, G; Preissel, A; Huisman, M; Poethko, T; Schuster, T; Yu, M; Robinson, S; Casebier, D; Henke, J; Wester, H J; Schwaiger, M

    2009-05-05

    Positron-emission tomography (PET) tracers for myocardial perfusion are commonly labeled with short-lived isotopes that limit their widespread clinical use. 18F-BMS-747158-02 (18F-BMS) is a novel pyridaben derivative that was evaluated for assessment of myocardial perfusion by comparison with 13N-ammonia (13NH3) and with radioactive microspheres in a pig model. Fourteen pigs injected with 500 MBq of 13NH3 or 100 to 200 MBq of 18F-BMS underwent dynamic PET at rest and during pharmacological stress. In 8 of these pigs, 18F-BMS was injected during stress combined with transient, 2.5-minute constriction of the left anterior descending coronary artery. Radioactive microspheres were coinjected with 18F-BMS. Ratios of myocardial tracer uptake to surrounding tissues were determined, and myocardial blood flow was quantified by compartmental modeling. Both tracers showed high and homogeneous myocardial uptake. Compared with 13NH3, 18F-BMS showed higher activity ratios between myocardium and blood (rest 2.5 versus 4.1; stress 2.1 versus 5.8), liver (rest 1.2 versus 1.8; stress 0.7 versus 2.0), and lungs (rest 2.5 versus 4.2; stress 2.9 versus 6.4). Regional myocardial blood flow assessed with 18F-BMS PET showed good correlation (r=0.88, slope=0.84) and agreement (mean difference -0.10 [25th percentile -0.3, 75th percentile 0.1 mL x min(-1) x g(-1)]) with that measured with radioactive microspheres over a flow range from 0.1 to 3.0 mL x min(-1) x g(-1). The extent of defects induced by left anterior descending coronary artery constriction measured by 18F-BMS and microspheres also correlated closely (r=0.63, slope=1.1). 18F-BMS-747158-02 is a very attractive new PET perfusion tracer that allows quantitative assessment of regional myocardial perfusion over a wide flow range. The long half-life of 18F renders this tracer useful for clinical PET/CT applications in the workup of patients with suspected or proven coronary artery disease.

  19. SPECT (Single-Photon Emission Computerized Tomography) Scan

    MedlinePlus

    ... can become damaged or even die. Reduced pumping efficiency. SPECT can show how completely your heart chambers ... radioactive tracer SPECT scans aren't safe for women who are pregnant or breast-feeding because the ...

  20. HIDA Scan (Cholescintigraphy)

    MedlinePlus

    ... areas. Radioactive tracer found outside of your biliary system might indicate a leak. Your doctor will discuss the results with you. By Mayo Clinic Staff . Mayo Clinic Footer Legal Conditions and Terms Any use of this site ...

  1. A novel recession rate physics methodology for space applications at CIRA by means of CIRCE radioactive beam tracers

    NASA Astrophysics Data System (ADS)

    De Cesare, M.; Di Leva, A.; Del Vecchio, A.; Gialanella, L.

    2018-03-01

    Thermal protection systems (TPSs) of spacecrafts, either for single use or reusable, experience wear by ablation and erosion, due to the high heat fluxes during a re-entry phase in the atmosphere. The determination of the wear rate is a crucial point, which is presently mainly possible in aerospace on-ground measurements by means of invasive diagnostics. The purpose of this paper is to present novel contactless, online, high-sensitivity and non-intrusive diagnostics for wear measurements based on radioactive tracers. We propose the technique for future on-ground experiments that might later be developed to perform in-flight TPSs monitoring, thus significantly increasing the safety of the aerospace vehicles. The basic ideas of the method, its sensitivity investigated by GEANT4 simulations, and the future experimental validation are outlined.

  2. Direct accumulation pathway of radioactive cesium to fruit-bodies of edible mushroom from contaminated wood logs

    NASA Astrophysics Data System (ADS)

    Ohnuki, Toshihiko; Aiba, Yukitoshi; Sakamoto, Fuminori; Kozai, Naofumi; Niizato, Tadafumi; Sasaki, Yoshito

    2016-07-01

    This paper presents the accumulation process of radioactive Cs in edible mushrooms. We here first report the direct accumulation pathway of radioactive Cs from contaminated wood logs to the fruit-bodies of shiitake mushrooms through the basal portion of the stipe. In this pathway, radioactive Cs is not transported through the hyphae. This pathway results in a high accumulation of radioactive Cs in the fruit-body, more by the excess accumulation of radioactive Cs from the wood logs than that through the hyphae. We grew the fruit-bodies of Shiitake mushroom from radioactive-Cs-contaminated wood logs. The spatial distributions of radioactive Cs and Prussian blue as a tracer of interstitial water in the cross section of the wood log measured after the harvest of the fruit-body from the inoculated sawdust spawn area indicated that some fraction of the radioactive Cs and Prussian blue were transported directly to the basal portion of the stipe during the growth of the fruit-bodies.

  3. Carbon isotopes in the ocean model of the Community Earth System Model (CESM1)

    DOE PAGES

    Jahn, A.; Lindsay, K.; Giraud, X.; ...

    2015-08-05

    Carbon isotopes in the ocean are frequently used as paleoclimate proxies and as present-day geochemical ocean tracers. In order to allow a more direct comparison of climate model results with this large and currently underutilized data set, we added a carbon isotope module to the ocean model of the Community Earth System Model (CESM), containing the cycling of the stable isotope 13C and the radioactive isotope 14C. We implemented the 14C tracer in two ways: in the "abiotic" case, the 14C tracer is only subject to air–sea gas exchange, physical transport, and radioactive decay, while in the "biotic" version, themore » 14C additionally follows the 13C tracer through all biogeochemical and ecological processes. Thus, the abiotic 14C tracer can be run without the ecosystem module, requiring significantly fewer computational resources. The carbon isotope module calculates the carbon isotopic fractionation during gas exchange, photosynthesis, and calcium carbonate formation, while any subsequent biological process such as remineralization as well as any external inputs are assumed to occur without fractionation. Given the uncertainty associated with the biological fractionation during photosynthesis, we implemented and tested three parameterizations of different complexity. Compared to present-day observations, the model is able to simulate the oceanic 14C bomb uptake and the 13C Suess effect reasonably well compared to observations and other model studies. Lastly, at the same time, the carbon isotopes reveal biases in the physical model, for example, too sluggish ventilation of the deep Pacific Ocean.« less

  4. Positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging of macrophages in large vessel vasculitis: Current status and future prospects.

    PubMed

    Jiemy, William Febry; Heeringa, Peter; Kamps, Jan A A M; van der Laken, Conny J; Slart, Riemer H J A; Brouwer, Elisabeth

    2018-05-03

    Macrophages are key players in the pathogenesis of large-vessel vasculitis (LVV) and may serve as a target for diagnostic imaging of LVV. The radiotracer, 18 F-FDG has proven to be useful in the diagnosis of giant cell arteritis (GCA), a form of LVV. Although uptake of 18 F-FDG is high in activated macrophages, it is not a specific radiotracer as its uptake is high in any proliferating cell and other activated immune cells resulting in high non-specific background radioactivity especially in aging and atherosclerotic vessels which dramatically lowers the diagnostic accuracy. Evidence also exists that the sensitivity of 18 F-FDG PET drops in patients upon glucocorticoid treatment. Therefore, there is a clinical need for more specific radiotracers in imaging GCA to improve diagnostic accuracy. Numerous clinically established and newly developed macrophage targeted radiotracers for oncological and inflammatory diseases can potentially be utilized for LVV imaging. These tracers are more target specific and therefore may provide lower background radioactivity, higher diagnostic accuracy and the ability to assess treatment effectiveness. However, current knowledge regarding macrophage subsets in LVV lesions is limited. Further understanding regarding macrophage subsets in vasculitis lesion is needed for better selection of tracers and new targets for tracer development. This review summarizes the development of macrophage targeted tracers in the last decade and the potential application of macrophage targeted tracers currently used in other inflammatory diseases in imaging LVV. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  5. LETTER TO THE EDITOR: Combined optical and single photon emission imaging: preliminary results

    NASA Astrophysics Data System (ADS)

    Boschi, Federico; Spinelli, Antonello E.; D'Ambrosio, Daniela; Calderan, Laura; Marengo, Mario; Sbarbati, Andrea

    2009-12-01

    In vivo optical imaging instruments are generally devoted to the acquisition of light coming from fluorescence or bioluminescence processes. Recently, an instrument was conceived with radioisotopic detection capabilities (Kodak in Vivo Multispectral System F) based on the conversion of x-rays from the phosphorus screen. The goal of this work is to demonstrate that an optical imager (IVIS 200, Xenogen Corp., Alameda, USA), designed for in vivo acquisitions of small animals in bioluminescent and fluorescent modalities, can even be employed to detect signals due to radioactive tracers. Our system is based on scintillator crystals for the conversion of high-energy rays and a collimator. No hardware modifications are required. Crystals alone permit the acquisition of photons coming from an in vivo 20 g nude mouse injected with a solution of methyl diphosphonate technetium 99 metastable (Tc99m-MDP). With scintillator crystals and collimators, a set of measurements aimed to fully characterize the system resolution was carried out. More precisely, system point spread function and modulation transfer function were measured at different source depths. Results show that system resolution is always better than 1.3 mm when the source depth is less than 10 mm. The resolution of the images obtained with radioactive tracers is comparable with the resolution achievable with dedicated techniques. Moreover, it is possible to detect both optical and nuclear tracers or bi-modal tracers with only one instrument.

  6. ¹¹C-ORM-13070, a novel PET ligand for brain α₂C-adrenoceptors: radiometabolism, plasma pharmacokinetics, whole-body distribution and radiation dosimetry in healthy men.

    PubMed

    Luoto, Pauliina; Suilamo, Sami; Oikonen, Vesa; Arponen, Eveliina; Helin, Semi; Herttuainen, Jukka; Hietamäki, Johanna; Holopainen, Aila; Kailajärvi, Marita; Peltonen, Juha M; Rouru, Juha; Sallinen, Jukka; Scheinin, Mika; Virta, Jere; Virtanen, Kirsi; Volanen, Iina; Roivainen, Anne; Rinne, Juha O

    2014-10-01

    (11)C-labelled 1-[(S)-1-(2,3-dihydrobenzo[1,2]dioxin-2-yl)methyl]-4-(3-methoxy-methylpyridin-2-yl)-piperazine ((11)C-ORM-13070) is a novel PET tracer for imaging of α2C-adrenoceptors in the human brain. Brain α2C-adrenoceptors may be therapeutic targets in several neuropsychiatric disorders, including depression, schizophrenia and Alzheimer's disease. To validate the use of (11)C-ORM-13070 in humans, we investigated its radiometabolism, pharmacokinetics, whole-body distribution and radiation dose. Radiometabolism was studied in a test-retest setting in six healthy men. After intravenous injection of (11)C-ORM-13070, blood samples were drawn over 60 min. Plasma samples were analysed by radio-HPLC for intact tracer and its radioactive metabolites. Metabolite-corrected plasma time-activity curves were used for calculation of pharmacokinetics. In a separate group of 12 healthy men, the whole-body distribution of (11)C-ORM-13070 and radiation exposure were investigated by dynamic PET/CT imaging without blood sampling. Two radioactive metabolites of (11)C-ORM-13070 were detected in human arterial plasma. The proportion of unchanged (11)C-ORM-13070 decreased from 81 ± 4 % of total radioactivity at 4 min after tracer injection to 23 ± 4 % at 60 min. At least one of the radioactive metabolites penetrated into red blood cells, while the parent tracer remained in plasma. The apparent elimination rate constant and corresponding half-life of unchanged (11)C-ORM-13070 in arterial plasma were 0.0117 ± 0.0056 min(-1) and 73.6 ± 35.8 min, respectively. The organs with the highest absorbed doses were the liver (12 μSv/MBq), gallbladder wall (12 μSv/MBq) and pancreas (9.1 μSv/MBq). The mean effective dose was 3.9 μSv/MBq, with a range of 3.6 - 4.2 μSv/MBq. (11)C-ORM-13070 was rapidly metabolized in human subjects after intravenous injection. The effective radiation dose of (11)C-ORM-13070 was in the same range as that of other (11)C-labelled brain receptor tracers. An injection of 500 MBq of (11)C-ORM-13070 would expose a subject to 2.0 mSv of radiation. This supports the use of (11)C-ORM-13070 in repeated PET scans, for example, in receptor occupancy trials with novel drug candidates.

  7. Determination of Columbia River flow times from Pasco, Washington using radioactive tracers introduced by the Hanford reactors

    USGS Publications Warehouse

    Nelson, Jack L.; Perkins, R.W.; Haushild, W.L.

    1966-01-01

    Radioactive tracers introduced into the Columbia River in cooling water from the Hanford reactors were used to measure flow times downstream from Pasco, Washington, as far as Astoria, Oregon. The use of two tracer methods was investigated. One method used the decay of a steady release of Na24 (15-hour half-life) to determine flow times to various downstream locations, and flow times were also determined from the time required for peak concentration of instantaneous releases of I131 (8-day half-life) to reach these locations. Flow times determined from the simultaneous use of the two methods agreed closely. The measured flow times for the 224 miles from Pasco to Vancouver, Washington, ranged from 14.6 to 3.6 days, respectively, for discharges of 108,000 and 630,000 ft3/sec at Vancouver, Washington. A graphic relation for estimating flow times at discharges other than those measured and for several locations between Pasco and Vancouver was prepared from the data of tests made at four river discharges. Some limited data are also presented on the characteristics of dispersion of I131 in the Columbia River.

  8. 40 CFR 146.66 - Logging, sampling, and testing prior to new well operation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... establish accurate baseline data against which future measurements may be compared. A descriptive report... radioactive tracer survey; (iii) A temperature or noise log; (iv) A casing inspection log, if required by the...

  9. 40 CFR 146.66 - Logging, sampling, and testing prior to new well operation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... establish accurate baseline data against which future measurements may be compared. A descriptive report... radioactive tracer survey; (iii) A temperature or noise log; (iv) A casing inspection log, if required by the...

  10. 40 CFR 146.66 - Logging, sampling, and testing prior to new well operation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... establish accurate baseline data against which future measurements may be compared. A descriptive report... radioactive tracer survey; (iii) A temperature or noise log; (iv) A casing inspection log, if required by the...

  11. 40 CFR 146.66 - Logging, sampling, and testing prior to new well operation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... establish accurate baseline data against which future measurements may be compared. A descriptive report... radioactive tracer survey; (iii) A temperature or noise log; (iv) A casing inspection log, if required by the...

  12. 40 CFR 146.66 - Logging, sampling, and testing prior to new well operation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... establish accurate baseline data against which future measurements may be compared. A descriptive report... radioactive tracer survey; (iii) A temperature or noise log; (iv) A casing inspection log, if required by the...

  13. Plan for radionuclide tracer studies of the residence time distribution in the Wilsonville dissolver and preheater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jolley, R.L.; Begovich, J.M.; Brashear, H.R.

    1983-12-01

    Stimulus-response measurements using radiotracers to measure residence time distribution (RTD) and hydrodynamic parameters for the preheaters and dissolvers at the Ft. Lewis Solvent Refined Coal (SRC) and the Exxon Donor Solvent (EDS) coal conversion pilot plants are reviewed. A plan is also presented for a series of radioactive tracer studies proposed for the Advanced Coal Liquefaction Facility at Wilsonville, Alabama, to measure the RTD for the preheater and dissolvers in the SRC-I mode. The tracer for the gas phase will be /sup 133/Xe, and /sup 198/Au (on carbonized resin or as an aqueous colloidal suspension) will be used as themore » slurry tracer. Four experimental phases are recommended for the RTD tracer studies: (1) preheater; (2) dissolver with 100% takeoff; (3) dissolver with 100% takeoff and solids withdrawal; and (4) dissolver with 50% takeoff. Eighteen gas-tracer and 22 liquid-tracer injections are projected to accomplish the four experimental phases. Two to four tracer injections are projected for preliminary tests to ensure the capability of safe injection of the radiotracers and the collection of statistically significant data. A complete projected cost and time schedule is provided, including procurement of necessary components, preparation of the radiotracers, assembly and testing of tracer injection apparatus and detection systems, onsite work and tracer injections, laboratory experimentation, data analysis, and report writing.« less

  14. Wear Measurement of Highly Cross-linked UHMWPE using a 7Be Tracer Implantation Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wimmer, Markus A.; Laurent, Michael P.; Dwivedi, Yasha

    2013-01-01

    The very low wear rates achieved with the current highly cross-linked ultrahigh molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are there- fore being explored. The purpose of this study was to perform a proof-of-concept experiment on the use of the radioactive tracer beryllium-7 (7Be) for the determination of in vitro wear in a highly cross-linked orthopedic UHMWPE. Three cross-linked and four conventional UHMWPE pins made from compression- molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenousmore » distribution of implanted nuclei up to 8.5 lm below the surface. The pins were tested for wear in a six-station pin-on-flat appara- tus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and esti- mated to be 17 6 3 lg per million cycles. The conventional-to- cross-linked ratio of the wear rates was 13.1 6 0.8, in the expected range for these materials. Oxidative degradation dam- age from implantation was negligible; however, a weak depend- ence of wear on implantation dose was observed limiting the number of radioactive tracer atoms that can be introduced. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.« less

  15. Quantitative analysis of myocardial kinetics of 15-p-[iodine-125] iodophenylpentadecanoic acid.

    PubMed

    DeGrado, T R; Holden, J E; Ng, C K; Raffel, D M; Gatley, S J

    1989-07-01

    Myocardial extraction and the characteristic tissue clearance of radioactivity following bolus injections of a radioiodinated (125I) long chain fatty acid (LCFA) analog 15-p-iodophenylpentadecanoic acid (IPPA) were examined in the isolated perfused working rat heart. Radioactivity remaining in the heart was monitored with external scintillation probes. A compartmental model which included nonesterified tracer, catabolite, and complex lipid compartments successfully fitted tissue time-radioactivity residue curves, and gave a value for the rate of IPPA oxidation 1.8 times that obtained from steady-state release of tritiated water from labeled palmitic acid. The technique was sensitive to the impairment of LCFA oxidation in hearts of animals treated with the carnitine palmitoyltransferase I inhibitor, 2[5(4-chlorophenyl)pentyl]oxirane-2-carboxylate (POCA). IPPA or similar modified fatty acids may be better than 11C-labeled physiological fatty acids such as palmitate in this type of study, because efflux of unoxidized tracer and catabolite(s) from the heart are kinetically more distinct, and their contributions to the early data can be reliably separated. This technique may be suitable for extension to in vivo measurements with position tomography and appropriate modified fatty acids.

  16. Determination of the Isotopic Enrichment of 13C- and 2H-Labeled Tracers of Glucose Using High-Resolution Mass Spectrometry: Application to Dual- and Triple-Tracer Studies.

    PubMed

    Trötzmüller, Martin; Triebl, Alexander; Ajsic, Amra; Hartler, Jürgen; Köfeler, Harald; Regittnig, Werner

    2017-11-21

    Multiple-tracer approaches for investigating glucose metabolism in humans usually involve the administration of stable and radioactive glucose tracers and the subsequent determination of tracer enrichments in sampled blood. When using conventional, low-resolution mass spectrometry (LRMS), the number of spectral interferences rises rapidly with the number of stable tracers employed. Thus, in LRMS, both computational effort and statistical uncertainties associated with the correction for spectral interferences limit the number of stable tracers that can be simultaneously employed (usually two). Here we show that these limitations can be overcome by applying high-resolution mass spectrometry (HRMS). The HRMS method presented is based on the use of an Orbitrap mass spectrometer operated at a mass resolution of 100 000 to allow electrospray-generated ions of the deprotonated glucose molecules to be monitored at their exact masses. The tracer enrichment determination in blood plasma is demonstrated for several triple combinations of 13 C- and 2 H-labeled glucose tracers (e.g., [1- 2 H 1 ]-, [6,6- 2 H 2 ]-, [1,6- 13 C 2 ]glucose). For each combination it is shown that ions arising from 2 H-labeled tracers are completely differentiated from those arising from 13 C-labeled tracers, thereby allowing the enrichment of a tracer to be simply calculated from the observed ion intensities using a standard curve with curve parameters unaffected by the presence of other tracers. For each tracer, the HRMS method exhibits low limits of detection and good repeatability in the tested 0.1-15.0% enrichment range. Additionally, due to short sample preparation and analysis times, the method is well-suited for high-throughput determination of multiple glucose tracer enrichments in plasma samples.

  17. Representative Atmospheric Plume Development for Elevated Releases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eslinger, Paul W.; Lowrey, Justin D.; McIntyre, Justin I.

    2014-02-01

    An atmospheric explosion of a low-yield nuclear device will produce a large number of radioactive isotopes, some of which can be measured with airborne detection systems. However, properly equipped aircraft may not arrive in the region where an explosion occurred for a number of hours after the event. Atmospheric conditions will have caused the radioactive plume to move and diffuse before the aircraft arrives. The science behind predicting atmospheric plume movement has advanced enough that the location of the maximum concentrations in the plume can be determined reasonably accurately in real time, or near real time. Given the assumption thatmore » an aircraft can follow a plume, this study addresses the amount of atmospheric dilution expected to occur in a representative plume as a function of time past the release event. The approach models atmospheric transport of hypothetical releases from a single location for every day in a year using the publically available HYSPLIT code. The effective dilution factors for the point of maximum concentration in an elevated plume based on a release of a non-decaying, non-depositing tracer can vary by orders of magnitude depending on the day of the release, even for the same number of hours after the release event. However, the median of the dilution factors based on releases for 365 consecutive days at one site follows a power law relationship in time, as shown in Figure S-1. The relationship is good enough to provide a general rule of thumb for estimating typical future dilution factors in a plume starting at the same point. However, the coefficients of the power law function may vary for different release point locations. Radioactive decay causes the effective dilution factors to decrease more quickly with the time past the release event than the dilution factors based on a non-decaying tracer. An analytical expression for the dilution factors of isotopes with different half-lives can be developed given the power law expression for the non-decaying tracer. If the power-law equation for the median dilution factor, Df, based on a non-decaying tracer has the general form Df=a(×t)^(-b) for time t after the release event, then the equation has the form Df=e^(-λt)×a×t^(-b) for a radioactive isotope, where λ is the decay constant for the isotope.« less

  18. Evaluation of rapid dual-tracer 62Cu-PTSM + 62Cu-ATSM PET in dogs with spontaneously occurring tumors

    NASA Astrophysics Data System (ADS)

    Black, Noel F.; McJames, Scott; Rust, Thomas C.; Kadrmas, Dan J.

    2008-01-01

    We are developing methods for imaging multiple PET tracers in a single scan with staggered injections, where imaging measures for each tracer are separated and recovered using differences in tracer kinetics and radioactive decay. In this work, signal separation performance for rapid dual-tracer 62Cu-PTSM (blood flow) + 62Cu-ATSM (hypoxia) tumor imaging was evaluated in a large animal model. Four dogs with pre-existing tumors received a series of dynamic PET scans with 62Cu-PTSM and 62Cu-ATSM, permitting evaluation of a rapid dual-tracer protocol designed by previous simulation work. Several imaging measures were computed from the dual-tracer data and compared with those from separate, single-tracer imaging. Static imaging measures (e.g. SUV) for each tracer were accurately recovered from dual-tracer data. The wash-in (k1) and wash-out (k2) rate parameters for both tracers were likewise well recovered (r = 0.87-0.99), but k3 was not accurately recovered for PTSM (r = 0.19) and moderately well recovered for ATSM (r = 0.70). Some degree of bias was noted, however, which may potentially be overcome through further refinement of the signal separation algorithms. This work demonstrates that complementary information regarding tumor blood flow and hypoxia can be acquired by a single dual-tracer PET scan, and also that the signal separation procedure works effectively for real physiologic data with realistic levels of kinetic model mismatch. Rapid multi-tracer PET has the potential to improve tumor assessment for image-guide therapy and monitoring, and further investigation with these and other tracers is warranted.

  19. Evaluation of Rapid Dual-Tracer 62Cu-PTSM + 62Cu-ATSM PET in Dogs with Spontaneously-Occurring Tumors

    PubMed Central

    Black, Noel F.; McJames, Scott; Rust, Thomas C.; Kadrmas, Dan J.

    2013-01-01

    We are developing methods for imaging multiple PET tracers in a single scan with staggered injections, where imaging measures for each tracer are separated and recovered using differences in tracer kinetics and radioactive decay. In this work, signal-separation performance for rapid dual-tracer 62Cu-PTSM (blood flow) + 62Cu-ATSM (hypoxia) tumor imaging was evaluated in a large animal model. Four dogs with pre-existing tumors received a series of dynamic PET scans with 62Cu-PTSM and 62Cu-ATSM, permitting evaluation of a rapid dual-tracer protocol designed by previous simulation work. Several imaging measures were computed from the dual-tracer data and compared with those from separate, single-tracer imaging. Static imaging measures (e.g. SUV) for each tracer were accurately recovered from dual-tracer data. The wash-in (k1) and wash-out (k2) rate parameters for both tracers were likewise well recovered (r = 0.87 – 0.99), but k3 was not accurately recovered for PTSM (r = 0.19) and moderately well recovered for ATSM (r = 0.70). Some degree of bias was noted, however, which may potentially be overcome through further refinement of the signal-separation algorithms. This work demonstrates that complementary information regarding tumor blood flow and hypoxia can be acquired by a single dual-tracer PET scan, and also that the signal-separation procedure works effectively for real physiologic data with realistic levels of kinetic model-mismatch. Rapid multi-tracer PET has the potential to improve tumor assessment for image-guide therapy and monitoring, and further investigation with these and other tracers is warranted. PMID:18182698

  20. Measurement of ground water velocity using Rhodamine WT dye near Sheffield, Illinois

    USGS Publications Warehouse

    Garklavs, George; Toler, L.G.

    1985-01-01

    Ground-water flow velocity was estimated in a tract of land adjacent to a low-level radioactive-waste disposal site near Sheffield, Illinois, by measuring the time-of-travel between two wells spaced 110 feet apart. Rhodamine WT dye was the principal tracer used in the test. The leading edge and peak concentrations of Rhodamine WT were well defined. A ground-water velocity of 6.9 feet per day (2,500 feet per year) was computed from the arrival time of the leading edge of the tracer cloud. (USGS)

  1. Radiotracer investigation in gold leaching tanks.

    PubMed

    Dagadu, C P K; Akaho, E H K; Danso, K A; Stegowski, Z; Furman, L

    2012-01-01

    Measurement and analysis of residence time distribution (RTD) is a classical method to investigate performance of chemical reactors. In the present investigation, the radioactive tracer technique was used to measure the RTD of aqueous phase in a series of gold leaching tanks at the Damang gold processing plant in Ghana. The objective of the investigation was to measure the effective volume of each tank and validate the design data after recent process intensification or revamping of the plant. I-131 was used as a radioactive tracer and was instantaneously injected into the feed stream of the first tank and monitored at the outlet of different tanks. Both sampling and online measurement methods were used to monitor the tracer concentration. The results of measurements indicated that both the methods provided identical RTD curves. The mean residence time (MRT) and effective volume of each tank was estimated. The tanks-in-series model with exchange between active and stagnant volume was used and found suitable to describe the flow structure of aqueous phase in the tanks. The estimated effective volume of the tanks and high degree of mixing in tanks could validate the design data and confirmed the expectation of the plant engineer after intensification of the process. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Simplifying Logistics and Avoiding the Unnecessary in Patients With Breast Cancer Undergoing Sentinel Node Biopsy. A Prospective Feasibility Trial of the Preoperative Injection of Super Paramagnetic Iron Oxide Nanoparticles.

    PubMed

    Karakatsanis, A; Olofsson, H; Stålberg, P; Bergkvist, L; Abdsaleh, S; Wärnberg, F

    2018-06-01

    Sentinel node is routinely localized with the intraoperative use of a radioactive tracer, involving challenging logistics. Super paramagnetic iron oxide nanoparticle is a non-radioactive tracer with comparable performance that could allow for preoperative localization, would simplify the procedure, and possibly be of value in axillary mapping before neoadjuvant treatment. The current trial aimed to determine the a priori hypothesis that the injection of super paramagnetic iron oxide nanoparticles in the preoperative period for the localization of the sentinel node is feasible. This is a prospective feasibility trial, conducted from 9 September 2014 to 22 October 2014 at Uppsala University Hospital. In all, 12 consecutive patients with primary breast cancer planned for resection of the primary and sentinel node biopsy were recruited. Super paramagnetic iron oxide nanoparticles were injected in the preoperative visit in the outpatient clinic. The radioactive tracer ( 99 mTc) and the blue dye were injected perioperatively in standard fashion. A volunteer was injected with super paramagnetic iron oxide nanoparticles to follow the decline in the magnetic signal in the sentinel node over time. The primary outcome was successful sentinel node detection. Super paramagnetic iron oxide nanoparticles' detection after preoperative injection (3-15 days) was successful in all cases (100%). In the volunteer, axillary signal was presented for 4 weeks. No adverse effects were noted. Conclusion and relevance: Preoperative super paramagnetic iron oxide nanoparticles' injection is feasible and leads to successful detection of the sentinel node. That may lead to simplified logistics as well as the identification, sampling, and marking of the sentinel node in patients planned for neoadjuvant treatment.

  3. D-(/sup 3/H)aspartate retrograde labelling of callosal and association neurons of somatosensory areas I and II of cats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barbaresi, P.; Fabri, M.; Conti, F.

    Experiments were carried out on cats to ascertain whether corticocortical neurons of somatosensory areas I (SI) and II (SII) could be labelled by retrograde axonal transport of D-(/sup 3/H)aspartate (D-(/sup 3/H)Asp). This tritiated enantiomer of the amino acid aspartate is (1) taken up selectively by axon terminals of neurons releasing aspartate and/or glutamate as excitatory neurotransmitter, (2) retrogradely transported and accumulated in perikarya, (3) not metabolized, and (4) visualized by autoradiography. A solution of D-(/sup 3/H)Asp was injected in eight cats in the trunk and forelimb zones of SI (two cats) or in the forelimb zone of SII (six cats).more » In order to compare the labelling patterns obtained with D-(/sup 3/H)Asp with those resulting after injection of a nonselective neuronal tracer, horseradish peroxidase (HRP) was delivered mixed with the radioactive tracer in seven of the eight cats. Furthermore, six additional animals received HRP injections in SI (three cats; trunk and forelimb zones) or SII (three cats; forelimb zone). D-(/sup 3/H)Asp retrograde labelling of perikarya was absent from the ipsilateral thalamus of all cats injected with the radioactive tracer but a dense terminal plexus of anterogradely labelled corticothalamic fibers from SI and SII was observed, overlapping the distribution area of thalamocortical neurons retrogradely labelled with HRP from the same areas. D-(/sup 3/H)Asp-labelled neurones were present in ipsilateral SII (SII-SI association neurones) in cats injected in SI. In these animals a bundle of radioactive fibres was observed in the rostral portion of the corpus callosum entering the contralateral hemisphere. There, neurones retrogradely labelled with silver grains were present in SI (SI-SI callosal neurons).« less

  4. Triple-Label β Liquid Scintillation Counting

    PubMed Central

    Bukowski, Thomas R.; Moffett, Tyler C.; Revkin, James H.; Ploger, James D.; Bassingthwaighte, James B.

    2010-01-01

    The detection of radioactive compounds by liquid scintillation has revolutionized modern biology, yet few investigators make full use of the power of this technique. Even though multiple isotope counting is considerably more difficult than single isotope counting, many experimental designs would benefit from using more than one isotope. The development of accurate isotope counting techniques enabling the simultaneous use of three β-emitting tracers has facilitated studies in our laboratory using the multiple tracer indicator dilution technique for assessing rates of transmembrane transport and cellular metabolism. The details of sample preparation, and of stabilizing the liquid scintillation spectra of the tracers, are critical to obtaining good accuracy. Reproducibility is enhanced by obtaining detailed efficiency/quench curves for each particular set of tracers and solvent media. The numerical methods for multiple-isotope quantitation depend on avoiding error propagation (inherent to successive subtraction techniques) by using matrix inversion. Experimental data obtained from triple-label β counting illustrate reproducibility and good accuracy even when the relative amounts of different tracers in samples of protein/electrolyte solutions, plasma, and blood are changed. PMID:1514684

  5. Synthesis and characterization of radiolabeled 17ß-estradiol conjugates

    USDA-ARS?s Scientific Manuscript database

    The use of radioactive tracers for environmental fate and transport studies of emerging contaminants, especially for those that are labile, offers convenience in tracking study compounds and their metabolites and in calculating mass-balances. The contribution of conjugated forms of natural steroid h...

  6. Influence of residual oxygen-15-labeled carbon monoxide radioactivity on cerebral blood flow and oxygen extraction fraction in a dual-tracer autoradiographic method.

    PubMed

    Iwanishi, Katsuhiro; Watabe, Hiroshi; Hayashi, Takuya; Miyake, Yoshinori; Minato, Kotaro; Iida, Hidehiro

    2009-06-01

    Cerebral blood flow (CBF), cerebral metabolic rate of oxygen (CMRO(2)), oxygen extraction fraction (OEF), and cerebral blood volume (CBV) are quantitatively measured with PET with (15)O gases. Kudomi et al. developed a dual tracer autoradiographic (DARG) protocol that enables the duration of a PET study to be shortened by sequentially administrating (15)O(2) and C(15)O(2) gases. In this protocol, before the sequential PET scan with (15)O(2) and C(15)O(2) gases ((15)O(2)-C(15)O(2) PET scan), a PET scan with C(15)O should be preceded to obtain CBV image. C(15)O has a high affinity for red blood cells and a very slow washout rate, and residual radioactivity from C(15)O might exist during a (15)O(2)-C(15)O(2) PET scan. As the current DARG method assumes no residual C(15)O radioactivity before scanning, we performed computer simulations to evaluate the influence of the residual C(15)O radioactivity on the accuracy of measured CBF and OEF values with DARG method and also proposed a subtraction technique to minimize the error due to the residual C(15)O radioactivity. In the simulation, normal and ischemic conditions were considered. The (15)O(2) and C(15)O(2) PET count curves with the residual C(15)O PET counts were generated by the arterial input function with the residual C(15)O radioactivity. The amounts of residual C(15)O radioactivity were varied by changing the interval between the C(15)O PET scan and (15)O(2)-C(15)O(2) PET scan, and the absolute inhaled radioactivity of the C(15)O gas. Using the simulated input functions and the PET counts, the CBF and OEF were computed by the DARG method. Furthermore, we evaluated a subtraction method that subtracts the influence of the C(15)O gas in the input function and PET counts. Our simulations revealed that the CBF and OEF values were underestimated by the residual C(15)O radioactivity. The magnitude of this underestimation depended on the amount of C(15)O radioactivity and the physiological conditions. This underestimation was corrected by the subtraction method. This study showed the influence of C(15)O radioactivity in DARG protocol, and the magnitude of the influence was affected by several factors, such as the radioactivity of C(15)O, and the physiological condition.

  7. Flow optimization study of a batch microfluidics PET tracer synthesizing device

    PubMed Central

    Elizarov, Arkadij M.; Meinhart, Carl; van Dam, R. Michael; Huang, Jiang; Daridon, Antoine; Heath, James R.; Kolb, Hartmuth C.

    2010-01-01

    We present numerical modeling and experimental studies of flow optimization inside a batch microfluidic micro-reactor used for synthesis of human-scale doses of Positron Emission Tomography (PET) tracers. Novel techniques are used for mixing within, and eluting liquid out of, the coin-shaped reaction chamber. Numerical solutions of the general incompressible Navier Stokes equations along with time-dependent elution scalar field equation for the three dimensional coin-shaped geometry were obtained and validated using fluorescence imaging analysis techniques. Utilizing the approach presented in this work, we were able to identify optimized geometrical and operational conditions for the micro-reactor in the absence of radioactive material commonly used in PET related tracer production platforms as well as evaluate the designed and fabricated micro-reactor using numerical and experimental validations. PMID:21072595

  8. Recent Transport History of Fukushima Radioactivity in the Northeast Pacific Ocean.

    PubMed

    Smith, John N; Rossi, Vincent; Buesseler, Ken O; Cullen, Jay T; Cornett, Jack; Nelson, Richard; Macdonald, Alison M; Robert, Marie; Kellogg, Jonathan

    2017-09-19

    The large inventory of radioactivity released during the March, 2011 Fukushima Dai-ichi nuclear reactor accident in Japan spread rapidly across the North Pacific Ocean and was first observed at the westernmost station on Line P, an oceanographic sampling line extending 1500 km westward of British Columbia (BC), Canada in June 2012. Here, time series measurements of 134 Cs and 137 Cs in seawater on Line P and on the CLIVAR-P16N 152°W line reveal the recent transport history of the Fukushima radioactivity tracer plume through the northeast Pacific Ocean. During 2013 and 2014 the Fukushima plume spread onto the Canadian continental shelf and by 2015 and early 2016 it reached 137 Cs values of 6-8 Bq/m 3 in surface water along Line P. Ocean circulation model simulations that are consistent with the time series measurements of Fukushima 137 Cs indicate that the 2015-2016 results represent maximum tracer levels on Line P and that they will begin to decline in 2017-2018. The current elevated Fukushima 137 Cs levels in seawater in the eastern North Pacific are equivalent to fallout background levels of 137 Cs that prevailed during the 1970s and do not represent a radiological threat to human health or the environment.

  9. Radioisotope tracer studies in the NASA Skylab ethothermic brazing experiment M-552

    NASA Technical Reports Server (NTRS)

    Braski, D. N.; Adair, H. L.; Kobisk, E. H.

    1974-01-01

    The first use of radioisotope tracer for mapping flow patterns during brazing of metal components in a space environment (near-zero gravity) proved successful. A nickel ferrule was brazed to a nickel tube with Lithobraze BT (71.8% Ag, 28% Cu, 0.2% Li) which contained a trace amount of radioactive Ag-110. Mapping of the flow of the braze alloy in the annulus formed between the tube and the concentric ferrule was determined by counting the radiation intensity as a function of position in the braze joint. Significant information concerning the thermal history of the braze was determined.

  10. Sputtering of cobalt and chromium by argon and xenon ions near the threshold energy region

    NASA Technical Reports Server (NTRS)

    Handoo, A. K.; Ray, P. K.

    1993-01-01

    Sputtering yields of cobalt and chromium by argon and xenon ions with energies below 50 eV are reported. The targets were electroplated on copper substrates. Measurable sputtering yields were obtained from cobalt with ion energies as low as 10 eV. The ion beams were produced by an ion gun. A radioactive tracer technique was used for the quantitative measurement of the sputtering yield. Co-57 and Cr-51 were used as tracers. The yield-energy curves are observed to be concave, which brings into question the practice of finding threshold energies by linear extrapolation.

  11. Precautions for Workers 1

    PubMed Central

    Guest, G. H.

    1948-01-01

    Radioactive isotopes are now available from Chalk River for use by Canadian biologists. Experience has shown that the handling of radioactive isotopes may involve health hazards unless adequate precautions are taken. The nature of these hazards and the type of precautions which must be taken when working with radioactive isotopes are considered. Successful work with radioactive isotopes other than in the smallest tracer amounts requires the use of laboratories and equipment especially designed for the purpose and this is dealt with briefly. The operation of a radioactive laboratory requires certain auxiliary equipment and services, such as health instruments, film monitoring, special laboratory clothing, special cleanable surfaces and disposal of radioactive waste materials. These topics are discussed briefly. Handling of radioactive isotopes involves certain special precautions and a few of these, such as protection of hands, cleaning of glassware, handling of solutions, etc. are reviewed. In addition to protecting all personnel in a laboratory from harmful amounts of radiation, it is necessary to keep the laboratory and the building in which it is housed as free as possible from radioactive substances and this important fact has been stressed. ImagesFig. 1.Fig. 4.Fig. 6. PMID:17648375

  12. Mass Spectrometric Determination of Uranium and Thorium in High Radiopurity Polymers Using Ultra Low Background Electroformed Copper Crucibles for Dry Ashing.

    PubMed

    Arnquist, Isaac J; Hoppe, Eric J; Bliss, Mary; Grate, Jay W

    2017-03-07

    A rapid new method for determining the U and Th mass concentrations in high radiopurity plastics is described, consisting of (1) dry ashing the plastic sample and tracers in low mass crucibles made of ultra low background electroformed copper (ULB EF-Cu) foil cut and folded into boats, (2) dissolving both the ash and the boat in acid, (3) performing a column separation to remove copper, and (4) determining the elements of interest by isotope dilution mass spectrometry. This method was demonstrated on both unfluorinated and fluorinated plastics, demonstrating high tracer recoveries and detection limits to pg/g (i.e., parts per trillion) levels or below, corresponding to μBq/kg of material. Samples of biomedical polyester (Max-Prene 955) and a fluoropolymer (polyvinylidene fluoride, PVDF) were analyzed in powder raw material forms as well as solids in the form of pellets or injection molded parts. The polyester powder contained 6 pg/g and 2 pg/g for 232 Th and 238 U, respectively. These levels correspond to 25 and 25 μBq/kg radioactivity, respectively. Determinations on samples of PVDF powder were typically below 1 pg/g for 232 Th and 2 pg/g for 238 U, corresponding to 4 and 25 μBq/kg radioactivity, respectively. The use of low mass ULB EF-Cu boats for dry ashing successfully overcame the problem of crucible-generated contaminants in the analysis; absolute detection limits, calculated as 3 × standard deviation of the process blanks, were typically 20-100 fg within a sample set. Complete dissolution of the ash and low mass boat provided high tracer recoveries and provides a convincing method to recover both the tracer and sample isotopes when full equilibration of tracer isotopes with sample isotopes is not possible prior to beginning chemical sample processing on solids.

  13. Mass Spectrometric Determination of Uranium and Thorium in High Radiopurity Polymers Using Ultra Low Background Electroformed Copper Crucibles for Dry Ashing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnquist, Isaac J.; Hoppe, Eric J.; Bliss, Mary

    A rapid new method for determining the U and Th mass concentrations in high radiopurity plastics is described, consisting of 1) dry ashing the plastic sample and tracers in low mass crucibles made of ultra low background electroformed copper (ULB EF-Cu) foil cut and folded into boats, 2) dissolving both the ash and the boat in acid, 3) performing a column separation to remove copper, and 4) determining the elements of interest by isotope dilution mass spectrometry. This method was demonstrated on both unfluorinated and fluorinated plastics, demonstrating high tracer recoveries and detection limits to pg/g (i.e., parts per trillion)more » levels or below, corresponding to μBq/kg of material. Samples of biomedical polyester (Max-Prene® 955) and a fluoropolymer (polyvinylidene fluoride, PVDF) were analyzed in powder raw material forms as well as solids in the form of pellets or injection molded parts. The polyester powder contained 6 pg/g and 2 pg/g for Th and U respectively. These levels correspond to 25 and 25 μBq/kg radioactivity, respectively. Determinations on samples of PVDF powder were typically below 1 pg/g for Th and 2 pg/g for U, corresponding to 4 and 25 μBq/kg radioactivity, respectively. The use of low mass ULB EF-Cu boats for dry ashing successfully overcame the problem of crucible-generated contaminants in the analysis; absolute detection limits, calculated as 3 × standard deviation of the process blanks, were typically 20-100 fg within a sample set. Complete dissolution of the ash and low mass boat provided high tracer recoveries, and provides a convincing method to recover both the tracer and sample isotopes when full equilibration of tracer isotopes with sample isotopes is not possible prior to beginning chemical sample processing on solids.« less

  14. Single-scan dual-tracer FLT+FDG PET tumor characterization.

    PubMed

    Kadrmas, Dan J; Rust, Thomas C; Hoffman, John M

    2013-02-07

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both (18)F-fluorodeoxyglucose (FDG) and (18)F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems--both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10-60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), K(net), and K(1) as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k(2), k(3)) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies in five patients with primary brain tumors where the data from separate scans of each tracer were combined to synthesize dual-tracer scans with known single-tracer components; results demonstrated similar dual-tracer signal recovery performance. We conclude that rapid dual-tracer FLT+FDG tumor imaging is feasible and can provide quantitative tumor imaging measures comparable to those from conventional separate-scan imaging.

  15. Single-scan dual-tracer FLT+FDG PET tumor characterization

    NASA Astrophysics Data System (ADS)

    Kadrmas, Dan J.; Rust, Thomas C.; Hoffman, John M.

    2013-02-01

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both 18F-fluorodeoxyglucose (FDG) and 18F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems—both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10-60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), Knet, and K1 as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k2, k3) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies in five patients with primary brain tumors where the data from separate scans of each tracer were combined to synthesize dual-tracer scans with known single-tracer components; results demonstrated similar dual-tracer signal recovery performance. We conclude that rapid dual-tracer FLT+FDG tumor imaging is feasible and can provide quantitative tumor imaging measures comparable to those from conventional separate-scan imaging.

  16. Single-scan dual-tracer FLT+FDG PET tumor characterization

    PubMed Central

    Kadrmas, Dan J; Rust, Thomas C; Hoffman, John M

    2013-01-01

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both 18F-fluorodeoxyglucose (FDG) and 18F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems—both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10–60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), Knet, and K1 as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k2, k3) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies in five patients with primary brain tumors where the data from separate scans of each tracer were combined to synthesize dual-tracer scans with known single-tracer components; results demonstrated similar dual-tracer signal recovery performance. We conclude that rapid dual-tracer FLT+FDG tumor imaging is feasible and can provide quantitative tumor imaging measures comparable to those from conventional separate-scan imaging. PMID:23296314

  17. Overview of SIMS-Based Experimental Studies of Tracer Diffusion in Solids and Application to Mg Self-Diffusion

    DOE PAGES

    Kulkarni, Nagraj S.; Bruce Warmack, Robert J.; Radhakrishnan, Bala; ...

    2014-09-23

    Tracer diffusivities provide the most fundamental information on diffusion in materials and are the foundation of robust diffusion databases. Compared to traditional radiotracer techniques that utilize radioactive isotopes, the secondary ion mass spectrometry (SIMS) based thin-film technique for tracer diffusion is based on the use of enriched stable isotopes that can be accurately profiled using SIMS. Experimental procedures & techniques that are utilized for the measurement of tracer diffusion coefficients are presented for pure magnesium, which presents some unique challenges due to the ease of oxidation. The development of a modified Shewmon-Rhines diffusion capsule for annealing Mg and an ultra-highmore » vacuum (UHV) system for sputter deposition of Mg isotopes are discussed. Optimized conditions for accurate SIMS depth profiling in polycrystalline Mg are provided. An automated procedure for the correction of heat-up and cool-down times during tracer diffusion annealing is discussed. The non-linear fitting of a SIMS depth profile data using the thin film Gaussian solution to obtain the tracer diffusivity along with the background tracer concentration and tracer film thickness is discussed. An Arrhenius fit of the Mg self-diffusion data obtained using the low-temperature SIMS measurements from this study and the high-temperature radiotracer measurements of Shewmon and Rhines (1954) was found to be a good representation of both types of diffusion data that cover a broad range of temperatures between 250 - 627° C (523 900 K).« less

  18. Three-dimensional pantograph for use in hazardous environments

    NASA Technical Reports Server (NTRS)

    Cowfer, C. D.; Wagner, H. A.

    1970-01-01

    Material measurement device is used with radioactive probes which can be approached only to distance of 3 feet. Tracer-following unit is capable of precisely controlled movement in X-Y-Z planes. Pantograph is usable in industrial processes involving chemical corrosives, poisons, and bacteriological hazards, as well as nuclear applications.

  19. Simple test of intestinal calcium absorption measured by stable strontium.

    PubMed Central

    Milsom, S; Ibbertson, K; Hannan, S; Shaw, D; Pybus, J

    1987-01-01

    A clinical test of intestinal calcium absorption has been developed using non-radioactive stable strontium as a calcium tracer. In nine elderly subjects there was a close correlation between the fractional absorption of strontium and radioactive calcium (45Ca) during a five hour period after the simultaneous oral administration of the two tracers. Comparable precision was achieved with each tracer in six subjects in whom the test was repeated after two weeks. The effect of food on strontium absorption was examined in a further 33 normal subjects (age 21-60 years), and the administration of the strontium with a standard breakfast was shown to reduce the variance at individual time points. A simplified test in which serum strontium concentration was measured four hours after the oral dose given with a standard breakfast was adopted as the routine procedure. The normal range (mean (2 SD], established over 97 tests in 53 patients, was 7.0-18.0% of the dose in the extracellular fluid. A further 30 patients with possible disorders of calcium absorption (10 with primary hyperparathyroidism and 20 with coeliac disease) were studied by this standard test. In both groups of patients the mean four hour strontium values were significantly different from normal. This standard strontium absorption test allows assessment of calcium absorption with sufficient sensitivity and precision to have a wide application in clinical practice. PMID:3115389

  20. A historical perspective on radioisotopic tracers in metabolism and biochemistry.

    PubMed

    Lappin, Graham

    2015-01-01

    Radioisotopes are used routinely in the modern laboratory to trace and quantify a myriad of biochemical processes. The technique has a captivating history peppered with groundbreaking science and with more than its share of Nobel Prizes. The discovery of radioactivity at the end of the 19th century paved the way to understanding atomic structure and quickly led to the use of radioisotopes to trace the fate of molecules as they flowed through complex organic life. The 1940s saw the first radiotracer studies using homemade instrumentation and analytical techniques such as paper chromatography. This article follows the history of radioisotopic tracers from meager beginnings, through to the most recent applications. The author hopes that those researchers involved in radioisotopic tracer studies today will pause to remember the origins of the technique and those who pioneered this fascinating science.

  1. Incorporating radioactive decay into charging and coagulation of multicomponent radioactive aerosols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Yong-ha; Yiacoumi, Sotira; Nenes, Athanasios

    Compositional changes by the decay of radionuclides in radioactive aerosols can influence their charging state, coagulation frequency and size distribution throughout their atmospheric lifetime. The importance of such effects is unknown as they have not been considered in microphysical and global radioactivity transport studies to date. Here, we explore the effects of compositional changes on the charging efficiency and coagulation rates of aerosols using a set of kinetic equations that couple all relevant processes (decay, charging and coagulation) and their evolution over time. Compared to a coupled aggregation-tracer model for the prediction of the radioactive composition of particulates undergoing coagulation,more » our kinetic approach can provide similar results using much less central processing unit time. Altogether with other considerations, our approach is computational efficient enough to allow implementation in 3D atmospheric transport models. The decay of radionuclides and the production of decay products within radioactive aerosols may significantly affect the aerosol charging rates, and either hinder or promote the coagulation of multicomponent radioactive aerosols. Our results suggest that radiological phenomena occurring within radioactive aerosols, as well as subsequent effects on aerosol microphysics, should be considered in regional and global models to more accurately predict radioactivity transport in the atmosphere in case of a nuclear plant accident.« less

  2. Incorporating radioactive decay into charging and coagulation of multicomponent radioactive aerosols

    DOE PAGES

    Kim, Yong-ha; Yiacoumi, Sotira; Nenes, Athanasios; ...

    2017-09-29

    Compositional changes by the decay of radionuclides in radioactive aerosols can influence their charging state, coagulation frequency and size distribution throughout their atmospheric lifetime. The importance of such effects is unknown as they have not been considered in microphysical and global radioactivity transport studies to date. Here, we explore the effects of compositional changes on the charging efficiency and coagulation rates of aerosols using a set of kinetic equations that couple all relevant processes (decay, charging and coagulation) and their evolution over time. Compared to a coupled aggregation-tracer model for the prediction of the radioactive composition of particulates undergoing coagulation,more » our kinetic approach can provide similar results using much less central processing unit time. Altogether with other considerations, our approach is computational efficient enough to allow implementation in 3D atmospheric transport models. The decay of radionuclides and the production of decay products within radioactive aerosols may significantly affect the aerosol charging rates, and either hinder or promote the coagulation of multicomponent radioactive aerosols. Our results suggest that radiological phenomena occurring within radioactive aerosols, as well as subsequent effects on aerosol microphysics, should be considered in regional and global models to more accurately predict radioactivity transport in the atmosphere in case of a nuclear plant accident.« less

  3. Microfluidics: a groundbreaking technology for PET tracer production?

    PubMed

    Rensch, Christian; Jackson, Alexander; Lindner, Simon; Salvamoser, Ruben; Samper, Victor; Riese, Stefan; Bartenstein, Peter; Wängler, Carmen; Wängler, Björn

    2013-07-05

    Application of microfluidics to Positron Emission Tomography (PET) tracer synthesis has attracted increasing interest within the last decade. The technical advantages of microfluidics, in particular the high surface to volume ratio and resulting fast thermal heating and cooling rates of reagents can lead to reduced reaction times, increased synthesis yields and reduced by-products. In addition automated reaction optimization, reduced consumption of expensive reagents and a path towards a reduced system footprint have been successfully demonstrated. The processing of radioactivity levels required for routine production, use of microfluidic-produced PET tracer doses in preclinical and clinical imaging as well as feasibility studies on autoradiolytic decomposition have all given promising results. However, the number of microfluidic synthesizers utilized for commercial routine production of PET tracers is very limited. This study reviews the state of the art in microfluidic PET tracer synthesis, highlighting critical design aspects, strengths, weaknesses and presenting several characteristics of the diverse PET market space which are thought to have a significant impact on research, development and engineering of microfluidic devices in this field. Furthermore, the topics of batch- and single-dose production, cyclotron to quality control integration as well as centralized versus de-centralized market distribution models are addressed.

  4. Evaluation of observed and modelled aerosol lifetimes using radioactive tracers of opportunity and an ensemble of 19 global models

    DOE PAGES

    Kristiansen, N. I.; Stohl, A.; Olivie, D. J. L.; ...

    2016-03-17

    Aerosols have important impacts on air quality and climate, but the processes affecting their removal from the atmosphere are not fully understood and are poorly constrained by observations. This makes modelled aerosol lifetimes uncertain. In this study, we make use of an observational constraint on aerosol lifetimes provided by radionuclide measurements and investigate the causes of differences within a set of global models. During the Fukushima Dai-Ichi nuclear power plant accident of March 2011, the radioactive isotopes cesium-137 ( 137Cs) and xenon-133 ( 133Xe) were released in large quantities. Cesium attached to particles in the ambient air, approximately according to theirmore » available aerosol surface area. 137Cs size distribution measurements taken close to the power plant suggested that accumulation-mode (AM) sulfate aerosols were the main carriers of cesium. Hence, 137Cs can be used as a proxy tracer for the AM sulfate aerosol's fate in the atmosphere. In contrast, the noble gas 133Xe behaves almost like a passive transport tracer. Global surface measurements of the two radioactive isotopes taken over several months after the release allow the derivation of a lifetime of the carrier aerosol. We compare this to the lifetimes simulated by 19 different atmospheric transport models initialized with identical emissions of 137Cs that were assigned to an aerosol tracer with each model's default properties of AM sulfate, and 133Xe emissions that were assigned to a passive tracer. We investigate to what extent the modelled sulfate tracer can reproduce the measurements, especially with respect to the observed loss of aerosol mass with time. Modelled 137Cs and 133Xe concentrations sampled at the same location and times as station measurements allow a direct comparison between measured and modelled aerosol lifetime. The e-folding lifetime τ e, calculated from station measurement data taken between 2 and 9 weeks after the start of the emissions, is 14.3 days (95 % confidence interval 13.1–15.7 days). The equivalent modelled τ e lifetimes have a large spread, varying between 4.8 and 26.7 days with a model median of 9.4 ± 2.3 days, indicating too fast a removal in most models. Because sufficient measurement data were only available from about 2 weeks after the release, the estimated lifetimes apply to aerosols that have undergone long-range transport, i.e. not for freshly emitted aerosol. However, modelled instantaneous lifetimes show that the initial removal in the first 2 weeks was quicker (lifetimes between 1 and 5 days) due to the emissions occurring at low altitudes and co-location of the fresh plume with strong precipitation. Deviations between measured and modelled aerosol lifetimes are largest for the northernmost stations and at later time periods, suggesting that models do not transport enough of the aerosol towards the Arctic. The models underestimate passive tracer ( 133Xe) concentrations in the Arctic as well but to a smaller extent than for the aerosol ( 137Cs) tracer. As a result, this indicates that in addition to too fast an aerosol removal in the models, errors in simulated atmospheric transport towards the Arctic in most models also contribute to the underestimation of the Arctic aerosol concentrations.« less

  5. Evaluation of Observed and Modelled Aerosol Lifetimes Using Radioactive Tracers of Opportunity and an Ensemble of 19 Global Models

    NASA Technical Reports Server (NTRS)

    Kristiansen, N. I.; Stohl, A.; Olivie, D. J. L.; Croft, B.; Sovde, O. A.; Klein, H.; Christoudias, T.; Kunkel, D.; Leadbetter, S. J.; Lee, Y. H.; hide

    2016-01-01

    Aerosols have important impacts on air quality and climate, but the processes affecting their removal from the atmosphere are not fully understood and are poorly constrained by observations. This makes modelled aerosol lifetimes uncertain. In this study, we make use of an observational constraint on aerosol lifetimes provided by radionuclide measurements and investigate the causes of differences within a set of global models. During the Fukushima Dai-Ichi nuclear power plant accident of March 2011, the radioactive isotopes cesium-137 (Cs-137) and xenon-133 (Xe-133) were released in large quantities. Cesium attached to particles in the ambient air, approximately according to their available aerosol surface area. Cs-137 size distribution measurements taken close to the power plant suggested that accumulation mode (AM) sulfate aerosols were the main carriers of cesium. Hence, Cs-137 can be used as a proxy tracer for the AM sulfate aerosol's fate in the atmosphere. In contrast, the noble gas Xe-133 behaves almost like a passive transport tracer. Global surface measurements of the two radioactive isotopes taken over several months after the release allow the derivation of a lifetime of the carrier aerosol. We compare this to the lifetimes simulated by 19 different atmospheric transport models initialized with identical emissions of Cs-137that were assigned to an aerosol tracer with each model's default properties of AM sulfate, and Xe-133 emissions that were assigned to a passive tracer. We investigate to what extent the modelled sulfate tracer can reproduce the measurements, especially with respect to the observed loss of aerosol mass with time. Modelled Cs-137and Xe-133 concentrations sampled at the same location and times as station measurements allow a direct comparison between measured and modelled aerosol lifetime. The e-folding lifetime e, calculated from station measurement data taken between 2 and 9 weeks after the start of the emissions, is 14.3 days (95% confidence interval 13.1-15.7 days). The equivalent modelled e lifetimes have a large spread, varying between 4.8 and 26.7 days with a model median of 9.42.3 days, indicating too fast a removal in most models. Because sufficient measurement data were only available from about 2 weeks after the release, the estimated lifetimes apply to aerosols that have undergone long-range transport, i.e. not for freshly emitted aerosol. However, modelled instantaneous lifetimes show that the initial removal in the first 2 weeks was quicker (lifetimes between 1 and 5 days) due to the emissions occurring at low altitudes and co-location of the fresh plume with strong precipitation. Deviations between measured and modelled aerosol lifetimes are largest for the northernmost stations and at later time periods, suggesting that models do not transport enough of the aerosol towards the Arctic. The models underestimate passive tracer (Xe-133) concentrations in the Arctic as well but to a smaller extent than for the aerosol (Cs-137) tracer. This indicates that in addition to too fast an aerosol removal in the models, errors in simulated atmospheric transport towards the Arctic in most models also contribute to the underestimation of the Arctic aerosol concentrations.

  6. Bioelimination of /sup 51/Cr and /sup 85/Sr by cockroaches, Gromphadorhina portentosa (Orthoptera: Blaberidae), as affected by mites, Gromphadorholaelaps schaeferi (parasitiformes: laelapidae)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schowalter, T.D.; Crossley, D.A. Jr.

    1982-03-01

    This paper describes rates of Chromium-51 and Strontium-85 assimilation and bioelimination by the hissing cockroach, Gromphadorhina portentosa (Schaum), when the symbiotic mite, Gromphadorholaelaps schaeferi Till, was present or removed. Mite-infested cockroaches had significantly higher rates of /sup 51/Cr elimination relative to mite-free cockroaches, implying more rapid gut clearance times. We did not find a significant mite effect on /sup 85/Sr elimination by the host, but mite effects could have been masked by the apparently unique process of nutrient assimilation and elimination by G. portentosa. Conventional models of radioactive tracer bioelimination predict a rapid initial loss of tracer due to gutmore » clearance, followed by a slower loss due to excretion of assimilated tracer. Our results indicated that assimilated /sup 85/Sr was eliminated earlier than unassimilated /sup 85/Sr was lost by defecation.« less

  7. Age-dependent Changes of Cerebral Copper Metabolism in Atp7b−/− Knockout Mouse Model of Wilson’s Disease by [64Cu]CuCl2-PET/CT

    PubMed Central

    Xie, Fang; Xi, Yin; Pascual, Juan M.; Muzik, Otto; Peng, Fangyu

    2017-01-01

    Copper is a nutritional metal required for brain development and function. Wilson’s disease (WD), or hepatolenticular degeneration, is an inherited human copper metabolism disorder caused by mutation of ATP7B gene. Many WD patients present with variable neurological and psychiatric symptoms, which may be related to neurodegeneration secondary to copper metabolism imbalance. The objective of this study is to explore feasibility and use of copper-64 chloride ([64C]CuCl2) as a tracer for noninvasive assessment of age-dependence changes of cerebral copper metabolism in WD using an Atp7b−/− knockout mouse model of WD and a positron emission tomography/computed tomography (PET/CT) scanner. Continuing from recent study of biodistribution and radiation dosimetry of [64C]CuCl2 in Atp7b−/− knockout mice, PET quantitative analysis revealed low 64Cu radioactivity in the brains of Atp7b−/− knockout mice at 7th week of age, compared with the 64Cu radioactivity in the brains of age and gender-matched wild type C57BL/6 mice, at 24 hour (h) post intravenous injection of [64C]CuCl2 as a tracer. Furthermore, age-dependent increase of 64Cu radioactivity was detected in the brains of Atp7b−/− knockout mice from 13th to 21th week of age, using the data derived from a longitudinal [64C]CuCl2-PET/CT study of Atp7b−/− knockout mice with orally administered [64Cu]CuCl2 as a tracer. The findings of this study support the use of [64Cu]CuCl2-PET/CT as a tool for noninvasive assessment of age-dependent changes of cerebral copper metabolism in WD patients presenting with variable neurological and psychiatric symptoms. PMID:28130615

  8. Age-dependent changes of cerebral copper metabolism in Atp7b -/- knockout mouse model of Wilson's disease by [64Cu]CuCl2-PET/CT.

    PubMed

    Xie, Fang; Xi, Yin; Pascual, Juan M; Muzik, Otto; Peng, Fangyu

    2017-06-01

    Copper is a nutritional metal required for brain development and function. Wilson's disease (WD), or hepatolenticular degeneration, is an inherited human copper metabolism disorder caused by a mutation of the ATP7B gene. Many WD patients present with variable neurological and psychiatric symptoms, which may be related to neurodegeneration secondary to copper metabolism imbalance. The objective of this study was to explore the feasibility and use of copper-64 chloride ([ 64 C]CuCl 2 ) as a tracer for noninvasive assessment of age-dependent changes of cerebral copper metabolism in WD using an Atp7b -/- knockout mouse model of WD and positron emission tomography/computed tomography (PET/CT) imaging. Continuing from our recent study of biodistribution and radiation dosimetry of [ 64 C]CuCl 2 in Atp7b -/- knockout mice, PET quantitative analysis revealed low 64 Cu radioactivity in the brains of Atp7b -/- knockout mice at 7th weeks of age, compared with 64 Cu radioactivity in the brains of age- and gender-matched wild type C57BL/6 mice, at 24 h (h) post intravenous injection of [ 64 C]CuCl 2 as a tracer. Furthermore, age-dependent increase of 64 Cu radioactivity was detected in the brains of Atp7b -/- knockout mice from the 13th to 21th weeks of age, based on the data derived from a longitudinal [ 64 C]CuCl 2 -PET/CT study of Atp7b -/- knockout mice with orally administered [ 64 Cu]CuCl 2 as a tracer. The findings of this study support clinical use of [ 64 Cu]CuCl 2 -PET/CT imaging as a tool for noninvasive assessment of age-dependent changes of cerebral copper metabolism in WD patients presenting with variable neurological and psychiatric symptoms.

  9. Compartmental Modeling and Dosimetry of in Vivo Metabolic Studies of Leucine and Three Secretory Proteins in Humans Using Radioactive Tracers

    NASA Astrophysics Data System (ADS)

    Venkatakrishnan, Vaidehi

    1995-01-01

    Physical and mathematical models provide a systematic means of looking at biological systems. Radioactive tracer kinetic studies open a unique window to study complex tracee systems such as protein metabolism in humans. This research deals with compartmental modeling of tracer kinetic data on leucine and apolipoprotein metabolism obtained using an endogenous tritiated leucine tracer administered as a bolus, and application of compartmental modeling techniques for dosimetric evaluation of metabolic studies of radioiodinated apolipoproteins. Dr. Waldo R. Fisher, Department of Medicine, was the coordinating research supervisor and the work was carried out in his laboratory. A compartmental model for leucine kinetics in humans has been developed that emphasizes its recycling pathways which were examined over two weeks. This model builds on a previously published model of Cobelli et al, that analyzed leucine kinetic data up to only eight hours. The proposed model includes different routes for re-entry of leucine from protein breakdown into plasma accounting for proteins which turn over at different rates. This new model successfully incorporates published models of three secretory proteins: albumin, apoA-I, and VLDL apoB, in toto thus increasing its validity and utility. The published model of apoA-I, based on an exogenous radioiodinated tracer, was examined with data obtained using an endogenous leucine tracer using compartmental techniques. The analysis concludes that the major portion of apoA-I enters plasma by a fast pathway but the major fraction of apoA-I in plasma resides with a second slow pathway; further the study is suggestive of a precursor-product relationship between the two plasma apoA-I pools. The possible relevance of the latter suggestion to the aberrant kinetics of apoA-I in Tangier disease is discussed. The analysis of apoA-II data resulted in similar conclusions. A methodology for evaluating the dosimetry of radioiodinated apolipoproteins by combining kinetic models of iodine and apolipoprotein metabolism has been developed. Residence times for source organs, whole body, thyroid, bladder, and red bone marrow obtained with this analysis, were used to calculate the cumulated activities and thus doses arising from these organs. The influence of the duration of the thyroid blocking period using stable iodine on the dose to the thyroid has been demonstrated.

  10. A PET Tracer for Brain α2C Adrenoceptors, (11)C-ORM-13070: Radiosynthesis and Preclinical Evaluation in Rats and Knockout Mice.

    PubMed

    Arponen, Eveliina; Helin, Semi; Marjamäki, Päivi; Grönroos, Tove; Holm, Patrik; Löyttyniemi, Eliisa; Någren, Kjell; Scheinin, Mika; Haaparanta-Solin, Merja; Sallinen, Jukka; Solin, Olof

    2014-07-01

    We report the development of a PET tracer for α2C adrenoceptor imaging and its preliminary preclinical evaluation. α2C adrenoceptors in the human brain may be involved in various neuropsychiatric disorders, such as depression, schizophrenia, and neurodegenerative diseases. PET tracers are needed for imaging of this receptor system in vivo. High-specific-activity (11)C-ORM-13070 (1-[(S)-1-(2,3-dihydrobenzo[1,4]dioxin-2-yl)methyl]-4-(3-(11)C-methoxymethylpyridin-2-yl)-piperazine) was synthesized by (11)C-methylation of O-desmethyl-ORM-13070 with (11)C-methyl triflate, which was prepared from cyclotron-produced (11)C-methane via (11)C-methyl iodide. Rats and mice were investigated in vivo with PET and ex vivo with autoradiography. The specificity of (11)C-ORM-13070 binding to α2 adrenoceptors was demonstrated in rats pretreated with atipamezole, an α2 adrenoceptor antagonist. The α2C adrenoceptor selectivity of the tracer was determined by comparing tracer binding in wild-type and α2A- and α2AC adrenoceptor knockout (KO) mice. (11)C-ORM-13070 and its radioactive metabolites in rat plasma and brain tissue were analyzed with radio-high-performance liquid chromatography and mass spectroscopy. Human radiation dose estimates were extrapolated from rat biodistribution data. The radiochemical yield, calculated from initial cyclotron-produced (11)C-methane, was 9.6% ± 2.7% (decay-corrected to end of bombardment). The specific activity of the product was 640 ± 390 GBq/μmol (decay-corrected to end of synthesis). The radiochemical purity exceeded 99% in all syntheses. The highest levels of tracer binding were observed in the striatum and olfactory tubercle of rats and control and α2A KO mice-that is, in the brain regions known to contain the highest densities of α2C adrenoceptors. In rats pretreated with atipamezole and in α2AC KO mice, (11)C tracer binding in the striatum and olfactory tubercle was low, similar to that of the frontal cortex and thalamus, regions with low densities of α2C adrenoceptors. Two radioactive metabolites were found in rat plasma, but only one of them was found in the brain; their identity was not revealed. The estimated effective radiation dose was comparable with the average exposure level in PET studies with (11)C tracers. An efficient method for the radiosynthesis of (11)C-ORM-13070 was developed. (11)C-ORM-13070 emerged as a potential novel radiotracer for in vivo imaging of brain α2C adrenoceptors. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantone, M.C.

    The interest in biokinetic studies is driven by problems related to the physiopathology of oligoelements, chemical elemental pollution and radioactive release in case of nuclear accidents. The application of stable isotopes as tracers in studies of trace elements in the area of nutritional and food science is particularly attractive and specifically if considering the investigations on the most radiosensitive age groups of the population and the repeated studies on healthy people for the assessment of the bioavailability of different compounds. A tracer method based on stable isotope administration, which combines the simultaneous use of two tracers and proton activation analysismore » is presented. A study aimed to obtain molybdenum biokinetic data in humans was performed. One tracer ({sup 96}Mo) was orally administered and another ({sup 95}Mo) was intravenously injected to two fasting volunteer subjects. Venous blood samples were withdrawn at different postinjection times. The concentration in plasma for both the isotopes was determined by measuring the intensities of the gamma-lines from the technetium radioisotopes produced via (p,n) reactions. In the adopted experimental conditions a minimum detectable concentration of 2 ng isotope/ml plasma was attained. The parameters describing molybdenum kinetics were obtained for the two individuals. Moreover, the investigation was repeated with different tracer amounts for one of the two subjects, in both fasting and non-fasting condition.« less

  12. Radioactive nondestructive test method

    NASA Technical Reports Server (NTRS)

    Obrien, J. R.; Pullen, K. E.

    1971-01-01

    Various radioisotope techniques were used as diagnostic tools for determining the performance of spacecraft propulsion feed system elements. Applications were studied in four tasks. The first two required experimental testing involving the propellant liquid oxygen difluoride (OF2): the neutron activation analysis of dissolved or suspended metals, and the use of radioactive tracers to evaluate the probability of constrictions in passive components (orifices and filters) becoming clogged by matter dissolved or suspended in the OF2. The other tasks were an appraisal of the applicability of radioisotope techniques to problems arising from the exposure of components to liquid/gas combinations, and an assessment of the applicability of the techniques to other propellants.

  13. [The clinical value of sentinel lymph node detection in laryngeal and hypopharyngeal carcinoma patients with clinically negative neck by methylene blue method and radiolabeled tracer method].

    PubMed

    Zhao, Xin; Xiao, Dajiang; Ni, Jianming; Zhu, Guochen; Yuan, Yuan; Xu, Ting; Zhang, Yongsheng

    2014-11-01

    To investigate the clinical value of sentinel lymph node (SLN) detection in laryngeal and hypopharyngeal carcinoma patients with clinically negative neck (cN0) by methylene blue method, radiolabeled tracer method and combination of these two methods. Thirty-three patients with cN0 laryngeal carcinoma and six patients with cN0 hypopharyngeal carcinoma underwent SLN detection using both of methylene blue and radiolabeled tracer method. All these patients were accepted received the injection of radioactive isotope 99 Tc(m)-sulfur colloid (SC) and methylene blue into the carcinoma before surgery, then all these patients underwent intraopertive lymphatic mapping with a handheld gamma-detecting probe and blue-dyed SLN. After the mapping of SLN, selected neck dissections and tumor resections were peformed. The results of SLN detection by radiolabeled tracer, dye and combination of both methods were compared. The detection rate of SLN by radiolabeled tracer, methylene blue and combined method were 89.7%, 79.5%, 92.3% respectively. The number of detected SLN was significantly different between radiolabeled tracer method and combined method, and also between methylene blue method and combined method. The detection rate of methylene blue and radiolabeled tracer method were significantly different from combined method (P < 0.05). Nine patients were found to have lymph node metastasis by final pathological examination. The accuracy and negative rate of SLN detection of the combined method were 97.2% and 11.1%. The combined method using radiolabeled tracer and methylene blue can improve the detection rate and accuracy of sentinel lymph node detection. Furthermore, sentinel lymph node detection can accurately represent the cervical lymph node status in cN0 laryngeal and hypopharyngeal carcinoma.

  14. Simulation of radioactive tracer transport using IsoRSM and uncertainty analysis

    NASA Astrophysics Data System (ADS)

    SAYA, A.; Chang, E.; Yoshimura, K.; Oki, T.

    2013-12-01

    Due to the massive earthquakes and tsunami on March 11 2011 in Eastern Japan, Fukushima Daiichi nuclear power plant was severely damaged and some reactors were exploded. To know how the radioactive materials were spread and how much they were deposited into the land, it is important to enhance the accuracy of radioactive transport simulation model. However, there are uncertainties in the models including dry and wet deposition process in the models, meteorological field and release amount of radioactive materials. In this study we analyzed these uncertainties aiming for higher accuracy in the simulation. We modified the stable isotope mode of Regional Spectral Model (IsoRSM, Yoshimura et al., 2009) to enable to simulate the transport of the radioactive tracers, namely iodine 131 and cesium 137, by including the dry and wet deposition processes. With this model, we conducted a set of sensitivity experiments using different parameters in the deposition processes, different diffusivity in advection processes, and different domain sizes. The control experiment with 10km resolution covering most of Japan and surrounding oceans (132.7oE-151.5oE &28.3oN-46.7oN) and the emission estimated by Chino et al. (2011) showed reasonable temporal results for Toukatsu area (eastern part of Tokyo metropolis and western part of Chiba prefecture where low-level contamination was occurred), i.e., on 22 March, the tracers from Fukushima were reached and precipitated in a significant amount as wet deposition. Thus we conducted 4 experimental simulations to analyze the simulation uncertainty due to 1) different meteorological pattern, different parameters for 2) wet and 3) dry deposition and 4) diffusion. Though the temporal patterns of deposition of radioactive particles were somewhat similar each other in all experiments, we revealed that the impacts to the area mean deposition were large. Results of the simulations with different diffusivity and different domain size showed that the patterns of precipitation amount and distribution, and deposition amount were affected. The new transport scheme, semi-lagrangian scheme could show some improvement in the simulated meteorological field. Furthermore, we have begun the inversion estimation combined with IsoRSM and the monitoring data from the Nuclear regulation Agency. Preliminary results with consecutive two week simulations starting every day with daily unit release will be shown at the conference. References 1. Yoshimura, K., Kanamitsu. M. and Dettinger. M.: Regional downscaling for stable water isotopes: A case study of an atmospheric river event, Journal of geophysical research, Vol.15, D18114, doi:10.1029/2010JD014032, 2010 2. Chino, M., Nakayama. H., Nagai. H., Terada. H., Katata. G. and Yamazawa. H.: Preliminary estimation of release amounts of 131I and 137Cs accidentally discharged from the Fukushima Daiichi Nuclear Power Plant into the atmosphere, Journal of Nuclear Science and Technology, Vol.48, No.7, p.1129-1134, 2011

  15. The Path of Carbon in Photosynthesis XVII. Phosphorus Compounds as Intermediates in Photosynthesis

    DOE R&D Accomplishments Database

    Buchanan, J. G.; Bassham, J. A.; Benson, A. A.; Bradley, D. F.; Calvin, M.; Daus, L. L.; Goodman, M.; Hayes, P. M.; Lynch, V. H.; Norris, L. T.; Wilson, A. T.

    1952-07-08

    Studies of carbon dioxide fixation in green plants using the C{sup 14} isotope have shown that in very short times phosphoglyceric acid contains most of the radioactivity. The tracer is present almost entirely in the carboxyl group. The importance of organic phosphates in the subsequent metabolism of phosphoglyceric acid can be seen from the accompanying photographs.

  16. Radon as a natural tracer for gas transport within uranium waste rock piles.

    PubMed

    Silva, N C; Chagas, E G L; Abreu, C B; Dias, D C S; Lopez, D; Guerreiro, E T Z; Alberti, H L C; Braz, M L; Branco, O; Fleming, P

    2014-07-01

    Acid mine drainage (AMD) has been identified as the main cause for outflow of acid water and radioactive/non-radioactive contaminants. AMD encompasses pyrites oxidation when water and oxygen are available. AMD was identified in uranium waste rock piles (WRPs) of Indústrias Nucleares do Brasil-Caldas facility (Brazilian uranium mine), resulting in high costs for water treatment. AMD reduction is the main challenge, and scientific investigation has been conducted to understand oxygen and water transportation within WRPs, where 222Rn is used as natural tracer for oxygen transportation. The study consists of soil radon gas mapping in the top layer of WRP4 using active soil gas pumping, radon adsorption in active charcoal and 222Rn determination using high-resolution gamma-ray spectrometry. A sampling network of 71 points was built where samples were collected at a depth of 40 cm. Soil radon gas concentration ranged from 33.7 to 1484.2 kBq m(-3) with mean concentration of 320.7±263.3 kBq m(-3). © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. USE OF RADIOISOTOPES IN THE STUDY OF METAL-TO-METAL WEAR OF HARDENED IRON- BASE ALLOYS. Quarterly Report No. 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talento, A.; Steven, G.

    1959-04-15

    A literature survey was made on the friction and wear of solid metals and on autoradiographic techniques as they apply to metal-to-metal wear studies. When two contacting surfaces are moving with respect to one another, the asperities weld together to form weld junctions. The number of junctions is large when no foreigm materials are on the contacting surfaces, but is greatly reduced by the presence of lubricants. Frictional forces are equal to the sum of the forces required to shear the weld junctions and the plough ing force. The rubbing surfaces may develop localized hot spots which may reach 2000more » F, and in these areas the metal is plastically deformed. Frictional forces and wear usually decrease as the hardness of the specimens increases. Autoradiographic techniques have been used to determine the location of radioactive tracers. Because photographic emulsions are sensitive to ionization caused by products of atomic disintegration, they are used to record the radiation given off by radioactive tracers. The wet and dry autoradiographic techniques that have been developed for metallurgical applications are described in this report. (auth)« less

  18. 237Np analytical method using 239Np tracers and application to a contaminated nuclear disposal facility

    DOE PAGES

    Snow, Mathew S.; Morrison, Samuel S.; Clark, Sue B.; ...

    2017-03-21

    In this study, environmental 237Np analyses are challenged by low 237Np concentrations and lack of an available yield tracer; we report a rapid, inexpensive 237Np analytical approach employing the short lived 239Np (t1/2 = 2.3 days) as a chemical yield tracer followed by 237Np quantification using inductively coupled plasma-mass spectrometry. 239Np tracer is obtained via separation from a 243Am stock solution and standardized using gamma spectrometry immediately prior to sample processing. Rapid digestions using a commercial, 900 W "Walmart" microwave and Parr microwave vessels result in 99.8 ± 0.1% digestion yields, while chromatographic separations enable Np/U separation factors on themore » order of 10 6 and total Np yields of 95 ± 4% (2σ). Application of this method to legacy soil samples surrounding a radioactive disposal facility (the Subsurface Disposal Area at Idaho National Laboratory) reveal the presence of low level 237Np contamination within 600 m of this site, with maximum 237Np concentrations on the order of 10 3 times greater than nuclear weapons testing fallout levels.« less

  19. 237 Np analytical method using 239 Np tracers and application to a contaminated nuclear disposal facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snow, Mathew S.; Morrison, Samuel S.; Clark, Sue B.

    2017-06-01

    Environmental 237Np analyses are challenged by low 237Np concentrations and lack of an available yield tracer; we report a rapid, inexpensive 237Np analytical approach employing the short lived 239Np (t1/2 = 2.3 days) as a chemical yield tracer followed by 237Np quantification using inductively coupled plasma-mass spectrometry. 239Np tracer is obtained via separation from a 243Am stock solution and standardized using gamma spectrometry immediately prior to sample processing. Rapid digestions using a commercial, 900 watt “Walmart” microwave and Parr microwave vessels result in 99.8 ± 0.1% digestion yields, while chromatographic separations enable Np/U separation factors on the order of 106more » and total Np yields of 95 ± 4% (2σ). Application of this method to legacy soil samples surrounding a radioactive disposal facility (the Subsurface Disposal Area at Idaho National Laboratory) reveal the presence of low level 237Np contamination within 600 meters of this site, with maximum 237Np concentrations on the order of 103 times greater than nuclear weapons testing fallout levels.« less

  20. 237Np analytical method using 239Np tracers and application to a contaminated nuclear disposal facility.

    PubMed

    Snow, Mathew S; Morrison, Samuel S; Clark, Sue B; Olson, John E; Watrous, Matthew G

    2017-06-01

    Environmental 237 Np analyses are challenged by low 237 Np concentrations and lack of an available yield tracer; we report a rapid, inexpensive 237 Np analytical approach employing the short lived 239 Np (t 1/2  = 2.3 days) as a chemical yield tracer followed by 237 Np quantification using inductively coupled plasma-mass spectrometry. 239 Np tracer is obtained via separation from a 243 Am stock solution and standardized using gamma spectrometry immediately prior to sample processing. Rapid digestions using a commercial, 900 W "Walmart" microwave and Parr microwave vessels result in 99.8 ± 0.1% digestion yields, while chromatographic separations enable Np/U separation factors on the order of 10 6 and total Np yields of 95 ± 4% (2σ). Application of this method to legacy soil samples surrounding a radioactive disposal facility (the Subsurface Disposal Area at Idaho National Laboratory) reveal the presence of low level 237 Np contamination within 600 m of this site, with maximum 237 Np concentrations on the order of 10 3 times greater than nuclear weapons testing fallout levels. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Bioelimination of /sup 51/Cr and /sup 85/Sr by cockroaches, Gromphadorhina portentosa (orthoptera: blaberidae), as affected by mites, Gromphadorholaelaps schaeferi (parasitiformes: laelapidae)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schowalter, T.D.; Crossley, D.A. Jr.

    1982-03-01

    The rates of Chromium-51 and Strontium-85 assimilation and bioelimination by the hissing cockroach, Gromphadorhina portentosa (Schaum) are described when the symbiotic mite, Gromphadorholaelaps schaeferi Till, was present or removed. Mite-infested cockroaches had significantly higher rates of /sup 51/Cr elimination relative to mite-free cockroaches, implying more rapid gut clearance times. The authors did not find a significant mite effect on /sup 85/Sr elimination by the host, but mite effects could have been masked by the apparently unique process of nutrient assimilation and elimination by G. portentosa. Conventional models of radioactive tracer bioelimination predict a rapid initial loss of tracer due tomore » gut clearance, followed by a slower loss due to excretion of assimilated tracer. The results indicated that assimilated /sup 85/Sr was eliminated earlier than unassimilated /sup 85/Sr, which was lost by defecation.« less

  2. Design and evaluation of radiotracers for determination of regional cerebral blood flow with PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lambrecht, R.M.; Duncan, C.C.; Shiue, C.Y.

    The tracer kinetics of 4-Fluoro(/sup 18/F)-, 4-Bromo(/sup 82/Br)- and 4-Iodo(/sup 125/I)-antipyrine and /sup 15/O-water were compared in a cat or baboon animal model. First-pass cerebral extraction and clearance with alterations in PaCO/sub 2/ were measured for whole brain. The Renkin/Crone model was used to evaluate brain capillary permeability-surface area product for 4-/sup 18/FAP in cats. Positron-emission-tomographic measurements required development of an instrument and technique for control of the arterial concentration of the radiotracer as a ramp function, so that tracer concentration changes due to radioactive decay or altered physiological processes could be accurately described with PET. Pharmacokinetic and tissue-distribution studiesmore » in cats were used to determine dosimetry for 4-/sup 18/FAP. 4-Bromoantipyrine labeled with /sup 78/Br (t = 6.5 m) is suggested as a tracer for determination of rCBF with PET.« less

  3. Transient tracer applications in the Southern Ocean

    NASA Astrophysics Data System (ADS)

    Stöven, T.; Tanhua, T.; Hoppema, M.

    2014-10-01

    Transient tracers can be used to constrain the Inverse-Gaussian transit time distribution (IG-TTD) and thus provide information about ocean ventilation. Individual transient tracers have different time and application ranges which are defined by their atmospheric history (chronological transient tracers) or their decay rate (radioactive transient tracers). The classification ranges from tracers for highly ventilated water masses, e.g. sulfur hexafluoride (SF6), the decay of Tritium (δ3H) and to some extent also dichlorodifluoromethane (CFC-12) to tracers for less ventilated deep ocean basins, e.g. CFC-12, Argon-39 (39Ar) and radiocarbon (14C). The IG-TTD can be empirically constrained by using transient tracer couples with sufficiently different input functions. Each tracer couple has specific characteristics which influence the application limit of the IG-TTD. Here we provide an overview of commonly used transient tracer couples and their validity areas within the IG-TTD by using the concept of tracer age differences (TAD). New measured CFC-12 and SF6 data from a section along 10° E in the Southern Ocean in 2012 are presented. These are combined with a similar data set of 1998 along 6° E in the Southern Ocean as well as with 39Ar data from the early 1980s in the western Atlantic Ocean and the Weddell Sea for investigating the application limit of the IG-TTD and to analyze changes in ventilation in the Southern Ocean. We found that the IG-TTD can be constrained south to 46° S which corresponds to the Subantarctic Front (SAF) denoting the application limit. The constrained IG-TTD north of the SAF shows a slight increase in mean ages between 1998 and 2012 in the upper 1200 m between 42-46° S. The absence of SF6 inhibits ventilation analyses below this depth. The time lag analysis between the 1998 and 2012 data shows an increase in ventilation down to 1000 m and a steady ventilation between 2000 m-bottom south of the SAF between 51-55° S.

  4. Using {sup 222}Rn as a tracer of geophysical processes in underground environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lacerda, T.; Anjos, R. M.; Valladares, D. L.

    2014-11-11

    Radon levels in two old mines in San Luis, Argentina, are reported and analyzed. These mines are today used for touristic visitation. Our goal was to assess the potential use of such radioactive noble gas as tracer of geological processes in underground environments. CR-39 nuclear track detectors were used during the winter and summer seasons. The findings show that the significant radon concentrations reported in this environment are subject to large seasonal modulations, due to the strong dependence of natural ventilation on the variations of outside temperature. The results also indicate that radon pattern distribution appear as a good methodmore » to localize unknown ducts, fissures or secondary tunnels in subterranean environments.« less

  5. Multi-tracer investigation of river and groundwater interactions: a case study in Nalenggele River basin, northwest China

    NASA Astrophysics Data System (ADS)

    Xu, Wei; Su, Xiaosi; Dai, Zhenxue; Yang, Fengtian; Zhu, Pucheng; Huang, Yong

    2017-11-01

    Environmental tracers (such as major ions, stable and radiogenic isotopes, and heat) monitored in natural waters provide valuable information for understanding the processes of river-groundwater interactions in arid areas. An integrated framework is presented for interpreting multi-tracer data (major ions, stable isotopes (2H, 18O), the radioactive isotope 222Rn, and heat) for delineating the river-groundwater interactions in Nalenggele River basin, northwest China. Qualitative and quantitative analyses were undertaken to estimate the bidirectional water exchange associated with small-scale interactions between groundwater and surface water. Along the river stretch, groundwater and river water exchange readily. From the high mountain zone to the alluvial fan, groundwater discharge to the river is detected by tracer methods and end-member mixing models, but the river has also been identified as a losing river using discharge measurements, i.e. discharge is bidirectional. On the delta-front of the alluvial fan and in the alluvial plain, in the downstream area, the characteristics of total dissolved solids values, 222Rn concentrations and δ18O values in the surface water, and patterns derived from a heat-tracing method, indicate that groundwater discharges into the river. With the environmental tracers, the processes of river-groundwater interaction have been identified in detail for better understanding of overall hydrogeological processes and of the impacts on water allocation policies.

  6. Advances in PET myocardial perfusion imaging: F-18 labeled tracers.

    PubMed

    Rischpler, Christoph; Park, Min-Jae; Fung, George S K; Javadi, Mehrbod; Tsui, Benjamin M W; Higuchi, Takahiro

    2012-01-01

    Coronary artery disease and its related cardiac disorders represent the most common cause of death in the USA and Western world. Despite advancements in treatment and accompanying improvements in outcome with current diagnostic and therapeutic modalities, it is the correct assignment of these diagnostic techniques and treatment options which are crucial. From a diagnostic standpoint, SPECT myocardial perfusion imaging (MPI) using traditional radiotracers like thallium-201 chloride, Tc-99m sestamibi or Tc-99m tetrofosmin is the most utilized imaging technique. However, PET MPI using N-13 ammonia, rubidium-82 chloride or O-15 water is increasing in availability and usage as a result of the growing number of medical centers with new-generation PET/CT systems taking advantage of the superior imaging properties of PET over SPECT. The routine clinical use of PET MPI is still limited, in part because of the short half-life of conventional PET MPI tracers. The disadvantages of these conventional PET tracers include expensive onsite production and inconvenient on-scanner tracer administration making them unsuitable for physical exercise stress imaging. Recently, two F-18 labeled radiotracers with longer radioactive half-lives than conventional PET imaging agents have been introduced. These are flurpiridaz F 18 (formerly known as F-18 BMS747158-02) and F-18 fluorobenzyltriphenylphosphonium. These longer half-life F-18 labeled perfusion tracers can overcome the production and protocol limitations of currently used radiotracers for PET MPI.

  7. Automatic and remote controlled ictal SPECT injection for seizure focus localization by use of a commercial contrast agent application pump.

    PubMed

    Feichtinger, Michael; Eder, Hans; Holl, Alexander; Körner, Eva; Zmugg, Gerda; Aigner, Reingard; Fazekas, Franz; Ott, Erwin

    2007-07-01

    In the presurgical evaluation of patients with partial epilepsy, the ictal single photon emission computed tomography (SPECT) is a useful noninvasive diagnostic tool for seizure focus localization. To achieve optimal SPECT scan quality, ictal tracer injection should be carried out as quickly as possible after the seizure onset and under highest safety conditions possible. Compared to the commonly used manual injection, an automatic administration of the radioactive tracer may provide higher quality standards for this procedure. In this study, therefore, we retrospectively analyzed efficiency and safety of an automatic injection system for ictal SPECT tracer application. Over a 31-month period, 26 patients underwent ictal SPECT by use of an automatic remote-controlled injection pump originally designed for CT-contrast agent application. Various factors were reviewed, including latency of ictal injection, radiation safety parameters, and ictal seizure onset localizing value. Times between seizure onset and tracer injection ranged between 3 and 48 s. In 21 of 26 patients ictal SPECT supported the localization of the epileptogenic focus in the course of the presurgical evaluation. In all cases ictal SPECT tracer injection was performed with a high degree of safety to patients and staff. Ictal SPECT by use of a remote-controlled CT-contrast agent injection system provides a high scan quality and is a safe and confirmatory presurgical evaluation technique in the epilepsy-monitoring unit.

  8. Metrology conditions for thin layer activation in wear and corrosion studies

    NASA Astrophysics Data System (ADS)

    Lacroix, O.; Sauvage, T.; Blondiaux, G.; Racolta, P. M.; Popa-Simil, L.; Alexandreanu, B.

    1996-02-01

    Thin Layer Activation (TLA) is an ion beam technique. This method consists of an accelerated ion bombardment of the surface of interest of a machine part subjected to wear. Radioactive tracers are created by nuclear reactions in a well defined volume of material. Loss of material owing to wear, corrosion or abrasion phenomena is characterized by monitoring the resulting changes in radioactivity. For the industrial application of this method, special attention has been paid during irradiation to the range of activated thickness, yields and activation homogeneity and to on-line radioactivity measurements. There are two basic methods for measuring the material loss by TLA technique. One of them is based on remanant radioactivity measurements using a previously obtained calibration curve. The second is based on measuring the increasing radioactivity in the lubricant due to suspended wear particles. In this paper, we have chosen to present some calibration curves for both proton and deuteron irradiation of Fe, Cr, Cu, Ti and Ni samples. Thickness ranges are indicated and intrinsic error checking and calculational procedures are also presented. The article ends with a review of some typical experiments involving running-in programme optimization and lubricants certifying procedures.

  9. Evaluation of 68Ga-labeled peptide tracer for detection of gelatinase expression after myocardial infarction in rat.

    PubMed

    Kiugel, Max; Kytö, Ville; Saanijoki, Tiina; Liljenbäck, Heidi; Metsälä, Olli; Ståhle, Mia; Tuomela, Johanna; Li, Xiang-Guo; Saukko, Pekka; Knuuti, Juhani; Roivainen, Anne; Saraste, Antti

    2016-12-02

    Matrix metalloproteinases 2 and 9 (MMP-2/9) play a role in extracellular matrix remodeling after an ischemic myocardial injury. We evaluated 68 Ga-DOTA-peptide targeting MMP-2/9 for the detection of gelatinase expression after myocardial infarction (MI) in rat. Rats were injected with 43 ± 7.7 MBq of 68 Ga-DOTA-peptide targeting MMP-2/9 at 7 days (n = 7) or 4 weeks (n = 8) after permanent coronary ligation or sham operation (n = 5 at both time points) followed by positron emission tomography (PET). The left ventricle was cut in frozen sections for autoradiography and immunohistochemistry 30 minutes after tracer injection. Immunohistochemical staining showed MMP-2 and MMP-9 expressing cells, CD31-positive endothelial cells, and CD68-positive macrophages in the infarcted myocardium. Autoradiography showed increased tracer uptake in the infarcted area both at 7 days and 4 weeks after MI (MI-to-remote area ratio 2.5 ± 0.46 and 3.1 ± 1.0, respectively). Tracer uptake in damaged tissue correlated with the amount of CD68-positive macrophages at 7 days after MI, and CD31-positive endothelial cells at 7 days and 4 weeks after MI. The tracer was rapidly metabolized, radioactivity in the blood exceeded that of the myocardium, and tracer accumulation in the heart was not detectable by in vivo PET. 68 Ga-DOTA-peptide targeting MMP-2/9 accumulates in the damaged rat myocardium after an ischemic injury, but tracer instability and slow clearance in vivo make it unsuitable for further evaluation.

  10. Separation of input function for rapid measurement of quantitative CMRO2 and CBF in a single PET scan with a dual tracer administration method

    NASA Astrophysics Data System (ADS)

    Kudomi, Nobuyuki; Watabe, Hiroshi; Hayashi, Takuya; Iida, Hidehiro

    2007-04-01

    Cerebral metabolic rate of oxygen (CMRO2), oxygen extraction fraction (OEF) and cerebral blood flow (CBF) images can be quantified using positron emission tomography (PET) by administrating 15O-labelled water (H152O) and oxygen (15O2). Conventionally, those images are measured with separate scans for three tracers C15O for CBV, H152O for CBF and 15O2 for CMRO2, and there are additional waiting times between the scans in order to minimize the influence of the radioactivity from the previous tracers, which results in a relatively long study period. We have proposed a dual tracer autoradiographic (DARG) approach (Kudomi et al 2005), which enabled us to measure CBF, OEF and CMRO2 rapidly by sequentially administrating H152O and 15O2 within a short time. Because quantitative CBF and CMRO2 values are sensitive to arterial input function, it is necessary to obtain accurate input function and a drawback of this approach is to require separation of the measured arterial blood time-activity curve (TAC) into pure water and oxygen input functions under the existence of residual radioactivity from the first injected tracer. For this separation, frequent manual sampling was required. The present paper describes two calculation methods: namely a linear and a model-based method, to separate the measured arterial TAC into its water and oxygen components. In order to validate these methods, we first generated a blood TAC for the DARG approach by combining the water and oxygen input functions obtained in a series of PET studies on normal human subjects. The combined data were then separated into water and oxygen components by the present methods. CBF and CMRO2 were calculated using those separated input functions and tissue TAC. The quantitative accuracy in the CBF and CMRO2 values by the DARG approach did not exceed the acceptable range, i.e., errors in those values were within 5%, when the area under the curve in the input function of the second tracer was larger than half of the first one. Bias and deviation in those values were also compatible to that of the conventional method, when noise was imposed on the arterial TAC. We concluded that the present calculation based methods could be of use for quantitatively calculating CBF and CMRO2 with the DARG approach.

  11. Advanced techniques for determining long term compatibility of materials with propellants

    NASA Technical Reports Server (NTRS)

    Green, R. L.; Stebbins, J. P.; Smith, A. W.; Pullen, K. E.

    1973-01-01

    A method for the prediction of propellant-material compatibility for periods of time up to ten years is presented. Advanced sensitive measurement techniques used in the prediction method are described. These include: neutron activation analysis, radioactive tracer technique, and atomic absorption spectroscopy with a graphite tube furnace sampler. The results of laboratory tests performed to verify the prediction method are presented.

  12. Atlantic Oceanography. Volume 1

    DTIC Science & Technology

    1978-08-01

    studies under aerobic and anaerobic conditions will be quantified (Ailor, 1971 ; Uhlig, 1971 ). Later studies will include the effect of pollutants on...an emphasis on deep sea bound- ary layer research. The round trip is $600 plus 4 days’ expenses. Literature Cited Ailor, W. H. 1971 . Handbook on...Measurement with radioactive tracer. Limnol. Oceanogr. (in press). Uhlig, H. H. 1971 . Corrosion and Corrosion Control. John Wiley & Sons, New York Wirsen

  13. [(11)C]UCB-A, a novel PET tracer for synaptic vesicle protein 2A.

    PubMed

    Estrada, Sergio; Lubberink, Mark; Thibblin, Alf; Sprycha, Margareta; Buchanan, Tim; Mestdagh, Nathalie; Kenda, Benoit; Mercier, Joel; Provins, Laurent; Gillard, Michel; Tytgat, Dominique; Antoni, Gunnar

    2016-06-01

    Development of a selective and specific high affinity PET tracer, [(11)C]UCB-A, for the in vivo study of SV2A expression in humans. Radiochemistry and preclinical studies in rats and pigs including development of a tracer kinetic model to determine VT. A method for the measurement of percent intact tracer in plasma was developed and the radiation dosimetry was determined in rats. 3-5GBq of [(11)C]UCB-A could be produced with radiochemical purity exceeding 98% with a specific radioactivity of around 65GBq/μmol. In vitro binding showed high selective binding towards SV2A. [(11)C]UCB-A displayed a dose-dependent and reversible binding to SV2A as measured with PET in rats and pigs and the VT could be determined by Logan analysis. The dosimetry was favorable and low enough to allow multiple administrations of [(11)C]UCB-A to healthy volunteers, and the metabolite analysis showed no sign of labeled metabolites in brain. We have developed the novel PET tracer, [(11)C]UCB-A, that can be used to measure SV2A expression in vivo. The dosimetry allows up to 5 administrations of 400MBq of [(11)C]UCB-A in humans. Apart from measuring drug occupancy, as we have shown, the tracer can potentially be used to compare SV2A expression between individuals because of the rather narrow range of baseline VT values. This will have to be further validated in human studies. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Field-scale sulfur hexafluoride tracer experiment to understand long distance gas transport in the deep unsaturated zone

    USGS Publications Warehouse

    Walvoord, Michelle Ann; Andraski, Brian J.; Green, Christopher T.; Stonestrom, David A.; Striegl, Robert G.

    2014-01-01

    A natural gradient SF6 tracer experiment provided an unprecedented evaluation of long distance gas transport in the deep unsaturated zone (UZ) under controlled (known) conditions. The field-scale gas tracer test in the 110-m-thick UZ was conducted at the U.S. Geological Survey’s Amargosa Desert Research Site (ADRS) in southwestern Nevada. A history of anomalous (theoretically unexpected) contaminant gas transport observed at the ADRS, next to the first commercial low-level radioactive waste disposal facility in the United States, provided motivation for the SF6 tracer study. Tracer was injected into a deep UZ borehole at depths of 15 and 48 m, and plume migration was observed in a monitoring borehole 9 m away at various depths (0.5–109 m) over the course of 1 yr. Tracer results yielded useful information about gas transport as applicable to the spatial scales of interest for off-site contaminant transport in arid unsaturated zones. Modeling gas diffusion with standard empirical expressions reasonably explained SF6 plume migration, but tended to underpredict peak concentrations for the field-scale experiment given previously determined porosity information. Despite some discrepancies between observations and model results, rapid SF6 gas transport commensurate with previous contaminant migration was not observed. The results provide ancillary support for the concept that apparent anomalies in historic transport behavior at the ADRS are the result of factors other than nonreactive gas transport properties or processes currently in effect in the undisturbed UZ.

  15. 18F-FDG labeling of mesenchymal stem cells and multipotent adult progenitor cells for PET imaging: effects on ultrastructure and differentiation capacity.

    PubMed

    Wolfs, Esther; Struys, Tom; Notelaers, Tineke; Roberts, Scott J; Sohni, Abhishek; Bormans, Guy; Van Laere, Koen; Luyten, Frank P; Gheysens, Olivier; Lambrichts, Ivo; Verfaillie, Catherine M; Deroose, Christophe M

    2013-03-01

    Because of their extended differentiation capacity, stem cells have gained great interest in the field of regenerative medicine. For the development of therapeutic strategies, more knowledge on the in vivo fate of these cells has to be acquired. Therefore, stem cells can be labeled with radioactive tracer molecules such as (18)F-FDG, a positron-emitting glucose analog that is taken up and metabolically trapped by the cells. The aim of this study was to optimize the radioactive labeling of mesenchymal stem cells (MSCs) and multipotent adult progenitor cells (MAPCs) in vitro with (18)F-FDG and to investigate the potential radiotoxic effects of this labeling procedure with a range of techniques, including transmission electron microscopy (TEM). Mouse MSCs and rat MAPCs were used for (18)F-FDG uptake kinetics and tracer retention studies. Cell metabolic activity, proliferation, differentiation and ultrastructural changes after labeling were evaluated using an Alamar Blue reagent, doubling time calculations and quantitative TEM, respectively. Additionally, mice were injected with MSCs and MAPCs prelabeled with (18)F-FDG, and stem cell biodistribution was investigated using small-animal PET. The optimal incubation period for (18)F-FDG uptake was 60 min. Significant early tracer washout was observed, with approximately 30%-40% of the tracer being retained inside the cells 3 h after labeling. Cell viability, proliferation, and differentiation capacity were not severely affected by (18)F-FDG labeling. No major changes at the ultrastructural level, considering mitochondrial length, lysosome size, the number of lysosomes, the number of vacuoles, and the average rough endoplasmic reticulum width, were observed with TEM. Small-animal PET experiments with radiolabeled MAPCs and MSCs injected intravenously in mice showed a predominant accumulation in the lungs and a substantial elution of (18)F-FDG from the cells. MSCs and MAPCs can be successfully labeled with (18)F-FDG for molecular imaging purposes. The main cellular properties are not rigorously affected. TEM confirmed that the cells' ultrastructural properties are not influenced by (18)F-FDG labeling. Small-animal PET studies confirmed the intracellular location of the tracer and the possibility of imaging injected prelabeled stem cell types in vivo. Therefore, direct labeling of MSCs and MAPCs with (18)F-FDG is a suitable technique to noninvasively assess cell delivery and early retention with PET.

  16. Validation of methodology for determination of the mercury methylation potential in sediments using radiotracers.

    PubMed

    Zizek, Suzana; Ribeiro Guevara, Sergio; Horvat, Milena

    2008-04-01

    Experiments to determine the mercury methylation potential were performed on sediments from two locations on the river Idrijca (Slovenia), differing in ambient mercury concentrations. The tracer used was the radioactive isotope (197)Hg. The benefit of using this tracer is its high specific activity, which enables spikes as low as 0.02 ng Hg(2+) g(-1) of sample to be used. It was therefore possible to compare the efficiency of the methylation potential experiments over a range of spike concentrations from picogram to microgram levels. The first part of the work aimed to validate the experimental blanks and the second part consisted of several series of incubation experiments on two different river sediments using a range of tracer additions. The results showed high variability in the obtained methylation potentials. Increasing Hg(2+) additions gave a decrease in the percentage of the tracer methylated during incubation; in absolute terms, the spikes that spanned four orders of magnitude (0.019-190 pg g(-1) of sediment slurry) resulted in MeHg formation between 0.01 and 0.1 ng MeHg g(-1) in Podroteja and Kozarska Grapa. Higher spikes resulted in slightly elevated MeHg production (up to a maximum of 0.27 ng g(-1)). The values of methylation potential were similar in both sediments. The results imply that the experimental determination of mercury methylation potential strongly depends on the experimental setup itself and the amount of tracer added to the system under study. It is therefore recommended to use different concentrations of tracer and perform the experiments in several replicates. The amount of mercury available for methylation in nature is usually very small. Therefore, adding very low amounts of tracer in the methylation potential studies probably gives results that have a higher environmental relevance. It is also suggested to express the results obtained in absolute amounts of MeHg produced and not just as the percentage of the added tracer.

  17. Mathematical Model of Estuarial Sediment Transport.

    DTIC Science & Technology

    1977-10-01

    This experience showed the central importance of the vertical diffusion coefficient and of the settling velocities of suspended aggregates. 150...34Report of Radioactive Tracer Studies, Sumatra ," Report prepared for Government Offices of Sumatra , 1975. 28. Strang, Gilbert and Fix, G. J., An...of the overall system as it is located at a turning basin . * Krone, R. B., "A Field Study of Flocculation as a Factor in Estuarial Shoaling

  18. [18F]FDG labeling of neural stem cells for in vivo cell tracking with positron emission tomography: inhibition of tracer release by phloretin.

    PubMed

    Stojanov, Katica; de Vries, Erik F J; Hoekstra, Dick; van Waarde, Aren; Dierckx, Rudi A J O; Zuhorn, Inge S

    2012-02-01

    The introduction of neural stem cells into the brain has promising therapeutic potential for the treatment of neurodegenerative diseases. To monitor the cellular replacement therapy, that is, to determine stem cell migration, survival, and differentiation, in vivo tracking methods are needed. Ideally, these tracking methods are noninvasive. Noninvasive tracking methods that have been successfully used for the visualization of blood-derived progenitor cells include magnetic resonance imaging and radionuclide imaging using single-photon emission computed tomography (SPECT) and positron emission tomography (PET). The SPECT tracer In-111-oxine is suitable for stem cell labeling, but for studies in small animals, the higher sensitivity and facile quantification that can be obtained with PET are preferred. Here the potential of 2'-[18F]fluoro-2'-deoxy-D-glucose ([18F]-FDG), a PET tracer, for tracking of neural stem cell (NSCs) trafficking toward an inflammation site was investigated. [18F]-FDG turns out to be a poor radiopharmaceutical to label NSCs owing to the low labeling efficiency and substantial release of radioactivity from these cells. Efflux of [18F]-FDG from NSCs can be effectively reduced by phloretin in vitro, but inhibition of tracer release is insufficient in vivo for accurate monitoring of stem cell trafficking.

  19. Human radiation studies: Remembering the early years. Oral history of biophysicist Cornelius A. Tobias, Ph.D., January 16, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-07-01

    Dr. Cornelius A. Tobias was interviewed by representatives of US DOE Office of Human Radiation Experiments (OHRE). He was chosen for this interview because of his extensive biophysics and medical physics research activities while he was employed by the University of California, Berkeley and San Francisco and at the Donner Laboratory. He discusses his involvement in wartime studies of effects of high altitude on aviators, carbon monoxide with radioactive tracers, blood studies with radioactive iron, human use committees, heavy-ion research with the Bevatron, boron isotope research, classified research involving human subjects, heavy-particle radiography, heavy- particle beams and medical research, andmore » pituitary irradiation studies,.« less

  20. Determination of radionuclides and radiochemical impurities produced by in-house cyclotron irradiation and subsequent radiosynthesis of PET tracers.

    PubMed

    Ishiwata, Kiichi; Hayashi, Kunpei; Sakai, Masanari; Kawauchi, Sugio; Hasegawa, Hideaki; Toyohara, Jun

    2017-01-01

    To elucidate the radionuclides and radiochemical impurities included in radiosynthesis processes of positron emission tomography (PET) tracers. Target materials and PET tracers were produced using a cyclotron/synthesis system from Sumitomo Heavy Industry. Positron and γ-ray emitting radionuclides were quantified by measuring radioactivity decay and using the high-purity Ge detector, respectively. Radiochemical species in gaseous and aqueous target materials were analyzed by gas and ion chromatography, respectively. Target materials had considerable levels of several positron emitters in addition to the positron of interest, and in the case of aqueous target materials extremely low levels of many γ-emitters. Five 11 C-, 15 O-, or 18 F-labeled tracers produced from gaseous materials via chemical reactions had no radionuclidic impurities, whereas 18 F-FDG, 18 F-NaF, and 13 N-NH 3 produced from aqueous materials had several γ-emitters as well as impure positron emitters. 15 O-Labeled CO 2 , O 2 , and CO had a radionuclidic impurity 13 N-N 2 (0.5-0.7 %). Target materials had several positron emitters other than the positron of interest, and extremely low level γ-emitters in the case of aqueous materials. PET tracers produced from gaseous materials except for 15 O-labeled gases had no impure radionuclides, whereas those derived from aqueous materials contained acceptable levels of impure positron emitters and extremely low levels of several γ-emitters.

  1. Comparison of dual-biomarker PIB-PET and dual-tracer PET in AD diagnosis.

    PubMed

    Fu, Liping; Liu, Linwen; Zhang, Jinming; Xu, Baixuan; Fan, Yong; Tian, Jiahe

    2014-11-01

    To identify the optimal time window for capturing perfusion information from early (11)C-PIB imaging frames (perfusion PIB, (11)C-pPIB) and to compare the performance of (18)F-FDG PET and "dual biomarker" (11)C-PIB PET [(11)C-pPIB and amyloid PIB ((11)C-aPIB)] for classification of AD, MCI and CN subjects. Forty subjects (14 CN, 12 MCI and 14 AD patients) underwent (18)F-FDG and (11)C-PIB PET studies. Pearson correlation between the (18)F-FDG image and sum of early (11)C-PIB frames was maximised to identify the optimal time window for (11)C-pPIB. The classification power of imaging parameters was evaluated with a leave-one-out validation. A 7-min time window yielded the highest correlation between (18)F-FDG and (11)C-pPIB. (11)C-pPIB and (18)F-FDG images shared a similar radioactive distribution pattern. (18)F-FDG performed better than (11)C-pPIB for the classification of both AD vs. CN and MCI vs. CN. (11)C-pPIB + (11)C-aPIB and (18)F-FDG + (11)C-aPIB yielded the highest classification accuracy for the classification of AD vs. CN, and (18)F-FDG + (11)C-aPIB had the best classification performance for the classification of MCI vs. C-pPIB could serve as a useful biomarker of rCBF for measuring neural activity and improve the diagnostic power of PET for AD in conjunction with (11)C-aPIB. (18)F-FDG and (11)C-PIB dual-tracer PET examination could better detect MCI. • Dual-tracer PET examination provides neurofunctional and neuropathological information for AD diagnosis. • The identified optimal 11C-pPIB time frames had highest correlation with 18F-FDG. • 11C-pPIB images shared a similar radioactive distribution pattern with 18F-FDG images. • 11C-pPIB can provide neurofunctional information. • Dual-tracer PET examination could better detect MCI.

  2. A double-tracer technique to characterize absorption, distribution, metabolism and excretion (ADME) of [14C]-basimglurant and absolute bioavailability after oral administration and concomitant intravenous microdose administration of [13C6]-labeled basimglurant in humans.

    PubMed

    Guerini, Elena; Schadt, Simone; Greig, Gerard; Haas, Ruth; Husser, Christophe; Zell, Manfred; Funk, Christoph; Hartung, Thomas; Gloge, Andreas; Mallalieu, Navita L

    2017-02-01

    1. The emerging technique of employing intravenous microdose administration of an isotope tracer concomitantly with an [ 14 C]-labeled oral dose was used to characterize the disposition and absolute bioavailability of a novel metabotropic glutamate 5 (mGlu5) receptor antagonist under clinical development for major depressive disorder (MDD). 2. Six healthy volunteers received a single 1 mg [ 12 C/ 14 C]-basimglurant (2.22 MBq) oral dose and a concomitant i.v. tracer dose of 100 μg of [ 13 C 6 ]-basimglurant. Concentrations of [ 12 C]-basimglurant and the stable isotope [ 13 C 6 ]-basimglurant were determined in plasma by a specific LC/MS-MS method. Total [ 14 C] radioactivity was determined in whole blood, plasma, urine and feces by liquid scintillation counting. Metabolic profiling was conducted in plasma, urine, blood cell pellet and feces samples. 3. The mean absolute bioavailability after oral administration (F) of basimglurant was ∼67% (range 45.7-77.7%). The major route of [ 14 C]-radioactivity excretion, primarily in form of metabolites, was in urine (mean recovery 73.4%), with the remainder excreted in feces (mean recovery 26.5%). The median t max for [ 12 C]-basimglurant after the oral administration was 0.71 h (range 0.58-1.00) and the mean terminal half-life was 77.2 ± 38.5 h. Terminal half-life for the [ 14 C]-basimglurant was 178 h indicating presence of metabolites with a longer terminal half-life. Five metabolites were identified with M1-Glucuronide as major and the others in trace amounts. There was minimal binding of drug to RBCs. IV pharmacokinetics was characterized with a mean ± SD CL of 11.8 ± 7.4 mL/h and a Vss of 677 ± 229 L. 4. The double-tracer technique used in this study allowed to simultaneously characterize the absolute bioavailability and disposition characteristics of the new oral molecular entity in a single study.

  3. Appearance of circulating and tissue /sup 14/C-lipids after oral /sup 14/C-tripalmitate administration in the late pregnant rat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Argiles, J.; Herrera, E.

    1989-02-01

    Studies were performed to determine whether and/or how dietary lipids participate in maternal hypertriglyceridemia during late gestation in the rat. After oral administration of glycerol-tri(1-14C)-palmitate, total radioactivity in plasma increased more rapidly in 20-day pregnant rats than in either 19-day pregnant rats or virgin controls. At the peak of plasma radioactivity, four hours after the tracer was administered, most of the plasma label corresponded to 14C-lipids in triglyceride-rich lipoproteins (d less than 1.006), and when expressed per micromol of triglyceride, values were higher in pregnant than in virgin rats. The difference was less after 24 hours, although at this timemore » the level of 14C-lipids in d less than 1.006 lipoproteins was still higher in 20-day pregnant rats than in virgins. Tissue 14C-lipids, as expressed per gram of fresh weight, were similar in pregnant and virgin rats, but the values in mammary glands were much higher in the former group. Estimated recovery of administered radioactivity four hours after tracer in total white adipose tissue, mammary glands, and plasma lipids was higher in pregnant than in virgin rats. No difference was found between 20-day pregnant and virgin rats either in the label retained in the gastrointestinal tract or in that exhaled as 14C-CO2 during the first four hours following oral administration of 14C-tripalmitate. These findings plus the known maternal hyperphagia, indicate that in the rat at late pregnancy triglyceride intestinal absorption is unchanged or even enhanced and that dietary lipids actively contribute to both maternal hypertriglyceridemia and lipid uptake by the mammary gland.« less

  4. Absorption and lymphatic transport of exogenous and endogenous arachidonic and linoleic acid in the rat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nilsson, A.; Landin, B.; Jensen, E.

    1987-06-01

    (/sup 3/H)Arachidonic (20:4) and (/sup 14/C)linoleic acid (18:2) were fed to thoracic duct-cannulated rats in test meals of either tracers alone, cream, Intralipid, pure arachidonic acid, or pure linoleic acid. Less (/sup 3/H)20:4 than (/sup 14/C)18:2 was recovered in chyle during the first 5 h. After cream feeding, the proportion of radioactivity found in phospholipids was high and increased during the first 3 h. After the meal 61 +/- 6% of the /sup 3/H and 57 +/- 10% of the /sup 14/C was in phosphatidylcholine, and 11 +/- 3% of the /sup 3/H and 3.0 +/- 4% of the /supmore » 14/C was in phosphatidylethanolamine. Changing the fat vehicle to Intralipid or pure 18:2 decreased the proportion of label in the phospholipds and increased the /sup 3/H and /sup 14/C radioactivity in the triacylglycerol fraction, the distribution of /sup 14/C radioactivity in the triacylglycerol fraction, the distribution of /sup 14/C being influenced more than that of /sup 3/H. After feeding the tracers in 200 ..mu..l of pure 20:4, >90% of both isotopes was in triacylglycerol. During fasting, triacylglycerol transported 56% (0.7 ..mu..mol/h), phosphatidylethanolamine transported 10% (0.1 ..mu..mol/h) of the 20:4 mass. After cream or Intralipid feeding, the output of 20:4-containing phosphatidylcholine and phosphatidylethanolamine increased 2.1- to 2.8-fold, whereas the transport of 20:4 with triacylglycerol remained constant. Phospholipids thus became the predominant transport form for 20:4. After feeding 200 ..mu..l of 20:4, the intestine produced, however, 20:4-rich triacylglycerols that transported 80% of the chyle 20:4.« less

  5. SEPARATION OF RADIOACTIVE COLUMBIUM TRACER

    DOEpatents

    Glendenin, L.E.; Gest, H.

    1958-08-26

    A process is presented for the recovery of radioactive columbium from solutions containing such columbium together with radioactive tellurium. The columbium and tellurium values are separated from such solutions by means of an inorganic oxide carrier precipitate, such as MnO/sub 2/. This oxide carrier precipitate and its associated columbium and telluriuan values are then dissolved in an aqueous acidic solution and nonradioactive tellurium, in an ionic form, is then introduced into such solution, for example in the form of H/sub 2/TeO/sub 3/. The tellurium present in the solution is then reduced to the elemental state and precipitates, and is then separated from the supernataat solution. A basic acetate precipitate is formed in the supernatant and carries the remaining columblum values therefrom. After separation, this basic ferric acetate precipitate is dissolved, and the ferric ions are removed by means of an organic solvent extraction process utilizing ether. The remaining solution contains carrier-free columbium as its only metal ion.

  6. Multiphase, multicomponent parameter estimation for liquid and vapor fluxes in deep arid systems using hydrologic data and natural environmental tracers

    USGS Publications Warehouse

    Kwicklis, Edward M.; Wolfsberg, Andrew V.; Stauffer, Philip H.; Walvoord, Michelle Ann; Sully, Michael J.

    2006-01-01

    Multiphase, multicomponent numerical models of long-term unsaturated-zone liquid and vapor movement were created for a thick alluvial basin at the Nevada Test Site to predict present-day liquid and vapor fluxes. The numerical models are based on recently developed conceptual models of unsaturated-zone moisture movement in thick alluvium that explain present-day water potential and tracer profiles in terms of major climate and vegetation transitions that have occurred during the past 10 000 yr or more. The numerical models were calibrated using borehole hydrologic and environmental tracer data available from a low-level radioactive waste management site located in a former nuclear weapons testing area. The environmental tracer data used in the model calibration includes tracers that migrate in both the liquid and vapor phases (??D, ??18O) and tracers that migrate solely as dissolved solutes (Cl), thus enabling the estimation of some gas-phase as well as liquid-phase transport parameters. Parameter uncertainties and correlations identified during model calibration were used to generate parameter combinations for a set of Monte Carlo simulations to more fully characterize the uncertainty in liquid and vapor fluxes. The calculated background liquid and vapor fluxes decrease as the estimated time since the transition to the present-day arid climate increases. However, on the whole, the estimated fluxes display relatively little variability because correlations among parameters tend to create parameter sets for which changes in some parameters offset the effects of others in the set. Independent estimates on the timing since the climate transition established from packrat midden data were essential for constraining the model calibration results. The study demonstrates the utility of environmental tracer data in developing numerical models of liquid- and gas-phase moisture movement and the importance of considering parameter correlations when using Monte Carlo analysis to characterize the uncertainty in moisture fluxes. ?? Soil Science Society of America.

  7. Optical imaging of reporter gene expression using a positron-emission-tomography probe

    NASA Astrophysics Data System (ADS)

    Liu, Hongguang; Ren, Gang; Liu, Shuanglong; Zhang, Xiaofen; Chen, Luxi; Han, Peizhen; Cheng, Zhen

    2010-11-01

    Reporter gene/reporter probe technology is one of the most important techniques in molecular imaging. Lately, many reporter gene/reporter probe systems have been coupled to different imaging modalities such as positron emission tomography (PET) and optical imaging (OI). It has been recently found that OI techniques could be used to monitor radioactive tracers in vitro and in living subjects. In this study, we further demonstrate that a reporter gene/nuclear reporter probe system [herpes simplex virus type-1 thymidine kinase (HSV1-tk) and 9-(4-18F-fluoro-3-[hydroxymethyl] butyl) guanine ([18F]FHBG)] could be successfully imaged by OI in vitro and in vivo. OI with radioactive reporter probes will facilitate and broaden the applications of reporter gene/reporter probe techniques in medical research.

  8. Electrodeposition of actinide compounds from an aqueous ammonium acetate matrix. Experimental development and optimization

    DOE PAGES

    Boll, Rose Ann; Matos, Milan; Torrico, Matthew N.

    2015-03-27

    Electrodeposition is a technique that is routinely employed in nuclear research for the preparation of thin solid films of actinide materials which can be used in accelerator beam bombardments, irradiation studies, or as radioactive sources. The present study investigates the deposition of both lanthanides and actinides from an aqueous ammonium acetate electrolyte matrix. Electrodepositions were performed primarily on stainless steel disks; with yield analysis evaluated using -spectroscopy. Experimental parameters were studied and modified in order to optimize the uniformity and adherence of the deposition while maximizing the yield. The initial development utilized samarium as the plating material, with and withoutmore » a radioactive tracer. As a result, surface characterization studies were performed by scanning electron microscopy, electron microprobe analysis, radiographic imaging, and x-ray diffraction.« less

  9. On the enterohepatic cycle of triiodothyronine in rats; importance of the intestinal microflora

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Herder, W.W.; Hazenberg, M.P.; Pennock-Schroeder, A.M.

    1989-01-01

    Until 70 h after a single iv injection of 10 uCi ({sup 125}I)triiodothyronine (T{sub 3}), normal rats excreted 15.8 {plus minus} 2.8% of the radioactivity with the feces and 17.5 {plus minus} 2.7% with the urine, while in intestine-decontaminated rats fecal and urinary excretion over this period amounted to 25.1 {plus minus} 7.2% and 23.6 {plus minus} 4.0% of administered radioactivity, respectively (mean {plus minus} SD, n=4). In fecal extracts of decontaminated rats 11.5 {plus minus} 6.8% of the excreted radioactivity consisted of T{sub 3} glucuronide (T{sub 3}G) and 10.9 {plus minus} 2.8% of T{sub 3} sulfate (T{sub 3}S), whereasmore » no conjugates were detected in feces from normal rats. Until 26 h after ig administration of 10 uCi ({sup 125}I)T{sub 3}, integrated radioactivity in blood of decontaminated rats was 1.5 times higher than that in normal rats. However, after ig administration of 10 uCi ({sup 125}I)T{sub 3}G or ({sup 125}I)T{sub 3}S, radioactivity in blood of decontaminated rats was 4.9- and 2.8-fold lower, respectively, than in normal rats. The radioactivity in the serum of control animals was composed of T{sub 3} and iodide in proportions independent of the tracer injected, while T{sub 3} conjugates represented <10 % of serum radioactivity. These results suggest an important role of the intestinal microflora in the enterohepatic circulation of T{sub 3} in rats.« less

  10. Tracking groundwater discharge to a large river using tracers and geophysics.

    PubMed

    Harrington, Glenn A; Gardner, W Payton; Munday, Tim J

    2014-01-01

    Few studies have investigated large reaches of rivers in which multiple sources of groundwater are responsible for maintaining baseflow. This paper builds upon previous work undertaken along the Fitzroy River, one of the largest perennial river systems in north-western Australia. Synoptic regional-scale sampling of both river water and groundwater for a suite of environmental tracers ((4) He, (87) Sr/(86) Sr, (222) Rn and major ions), and subsequent modeling of tracer behavior in the river, has enabled definition and quantification of groundwater input from at least three different sources. We show unambiguous evidence of both shallow "local" groundwater, possibly recharged to alluvial aquifers beneath the adjacent floodplain during recent high-flow events, and old "regional" groundwater introduced via artesian flow from deep confined aquifers. We also invoke hyporheic exchange and either bank return flow or parafluvial flow to account for background (222) Rn activities and anomalous chloride trends along river reaches where there is no evidence of the local or regional groundwater inputs. Vertical conductivity sections acquired through an airborne electromagnetic (AEM) survey provide insights to the architecture of the aquifers associated with these sources and general groundwater quality characteristics. These data indicate fresh groundwater from about 300 m below ground preferentially discharging to the river, at locations consistent with those inferred from tracer data. The results demonstrate how sampling rivers for multiple environmental tracers of different types-including stable and radioactive isotopes, dissolved gases and major ions-can significantly improve conceptualization of groundwater-surface water interaction processes, particularly when coupled with geophysical techniques in complex hydrogeological settings. © 2013, National Ground Water Association.

  11. Results of ground-water tracer tests using tritiated water at Oak Ridge National Laboratory, Tennessee

    USGS Publications Warehouse

    Webster, D.A.

    1996-01-01

    Ground-water tracer test were conducted at two sites in the radioactive-waste disposal area of Oak Ridge National Laboratory from 1977 to 1982. The purpose of the tests was to determine if the regolith beds had weathered sufficiently to permit the substantial flow of water across them. About 50 curies of tritium dissolved in water were used as the tracer in one site, and about 100 curies at the other. Results demonstrated that ground water is able to flow through joints in the weathered bedding and that the direction of the water-table gradient is the primary factor governint flow direction. Nevertheless, the substantial lateral spread of the plume as it developed showed that bedding-plane openings can still exert a significant secondary influence on flow direction in weathered rock. About 3,500 water samples from the injection and observation wells were analyzed for tritium during the test period. Concentrations detected spanned 11 orders of magnitude. Measurable concentrations were still present in the two injection wells and most observation wells 5 years after the tracer was introduced. Matrix diffusion may have played a significant role in these tests. The process would account for the sustained concentrations of tritium at many of the observation wells, the long-term residual concentrations at the injection and observation wells, and the apparent slow movement of the centers of mass across the two well fields. The process also would have implications regarding aquifer remediation. Other tracer tests have been conducted in the regolith of the Conasauga Group. Results differ from the results described in this report.

  12. Development of a Hybrid Tracer for SPECT and Optical Imaging of Bacterial Infections.

    PubMed

    Welling, Mick M; Bunschoten, Anton; Kuil, Joeri; Nelissen, Rob G H H; Beekman, Freek J; Buckle, Tessa; van Leeuwen, Fijs W B

    2015-05-20

    In trauma and orthopedic surgery, infection of implants has a major impact on the outcome for patients. Infections may develop either during the initial implantation or during the lifetime of an implant. Both infections, as well as aseptic loosening of the implant, are reasons for revision of the implants. Therefore, discrimination between aseptic-mechanical-loosening and septic-bacterial-loosening of implants is critical during selection of a patient-tailored treatment policy. Specific detection and visualization of infections is a challenge because it is difficult to discriminate infections from inflammation. An imaging tracer that facilitates bacterial identification in a pre- and intraoperative setting may aid the workup for patients suspicious of bacterial infections. In this study we evaluated an antimicrobial peptide conjugated to a hybrid label, which contains both a radioisotope and a fluorescent dye. After synthesis of DTPA-Cy5-UBI29-41 and-when necessary-radiolabeling with (111)In (yield 96.3 ± 2.7%), in vitro binding to various bacterial strains was evaluated using radioactivity counting and confocal fluorescence microscopy. Intramuscular bacterial infections (S. aureus or K. pneumoniae) were also visualized in vivo using a combined nuclear and fluorescence imaging system. The indium-111 was chosen as label as it has a well-defined coordination chemistry, and in pilot studies labeling DTPA-Cy5-UBI29-41 with technetium-99m, we encountered damage to the Cy5 dye after the reduction with SnCl2. As a reference, we used the validated tracer (99m)Tc-UBI29-41. Fast renal excretion of (111)In-DTPA-Cy5-UBI29-41 was observed. Target to nontarget (T/NT) ratios were highest at 2 h post injection: radioactivity counting yielded T/NT ratios of 2.82 ± 0.32 for S. aureus and 2.37 ± 0.05 for K. pneumoniae. Comparable T/NT ratios with fluorescence imaging of 2.38 ± 0.09 for S. aureus and 3.55 ± 0.31 for K. pneumoniae were calculated. Ex vivo confocal microscopy of excised infected tissues showed specific binding of the tracer to bacteria. Using a combination of nuclear and fluorescence imaging techniques, the hybrid antimicrobial peptide conjugate DTPA-Cy5-UBI29-41 was shown to specifically accumulate in bacterial infections. This hybrid tracer may facilitate integration of noninvasive identification of infections and their extent as well as real-time fluorescence guidance during surgical resection of infected areas.

  13. Comparison of the image-derived radioactivity and blood-sample radioactivity for estimating the clinical indicators of the efficacy of boron neutron capture therapy (BNCT): 4-borono-2-18F-fluoro-phenylalanine (FBPA) PET study.

    PubMed

    Isohashi, Kayako; Shimosegawa, Eku; Naka, Sadahiro; Kanai, Yasukazu; Horitsugi, Genki; Mochida, Ikuko; Matsunaga, Keiko; Watabe, Tadashi; Kato, Hiroki; Tatsumi, Mitsuaki; Hatazawa, Jun

    2016-12-01

    In boron neutron capture therapy (BNCT), positron emission tomography (PET) with 4-borono-2- 18 F-fluoro-phenylalanine (FBPA) is the only method to estimate an accumulation of 10 B to target tumor and surrounding normal tissue after administering 10 B carrier of L-paraboronophenylalanine and to search the indication of BNCT for individual patient. Absolute concentration of 10 B in tumor has been estimated by multiplying 10 B concentration in blood during BNCT by tumor to blood radioactivity (T/B) ratio derived from FBPA PET. However, the method to measure blood radioactivity either by blood sampling or image data has not been standardized. We compared image-derived blood radioactivity of FBPA with blood sampling data and studied appropriate timing and location for measuring image-derived blood counts. We obtained 7 repeated whole-body PET scans in five healthy subjects. Arterialized venous blood samples were obtained from the antecubital vein, heated in a heating blanket. Time-activity curves (TACs) of image-derived blood radioactivity were obtained using volumes of interest (VOIs) over ascending aorta, aortic arch, pulmonary artery, left and right ventricles, inferior vena cava, and abdominal aorta. Image-derived blood radioactivity was compared with those measured by blood sampling data in each location. Both the TACs of blood sampling radioactivity in each subject, and the TACs of image-derived blood radioactivity showed a peak within 5 min after the tracer injection, and promptly decreased soon thereafter. Linear relationship was found between blood sampling radioactivity and image-derived blood radioactivity in all the VOIs at any timing of data sampling (p < 0.001). Image-derived radioactivity measured in the left and right ventricles 30 min after injection showed high correlation with blood radioactivity. Image-derived blood radioactivity was lower than blood sampling radioactivity data by 20 %. Reduction of blood radioactivity of FBPA in left ventricle after 30 min of FBPA injection was minimal. We conclude that the image-derived T/B ratio can be reliably used by setting the VOI on the left ventricle at 30 min after FBPA administration and correcting for underestimation due to partial volume effect and reduction of FBPA blood radioactivity.

  14. A new compartmental method for the analysis of liver FDG kinetics in small animal models.

    PubMed

    Garbarino, Sara; Vivaldi, Valentina; Delbary, Fabrice; Caviglia, Giacomo; Piana, Michele; Marini, Cecilia; Capitanio, Selene; Calamia, Iolanda; Buschiazzo, Ambra; Sambuceti, Gianmario

    2015-12-01

    Compartmental analysis is a standard method to quantify metabolic processes using fluorodeoxyglucose-positron emission tomography (FDG-PET). For liver studies, this analysis is complex due to the hepatocyte capability to dephosphorylate and release glucose and FDG into the blood. Moreover, a tracer is supplied to the liver by both the hepatic artery and the portal vein, which is not visible in PET images. This study developed an innovative computational approach accounting for the reversible nature of FDG in the liver and directly computing the portal vein tracer concentration by means of gut radioactivity measurements. Twenty-one mice were subdivided into three groups: the control group 'CTR' (n = 7) received no treatment, the short-term starvation group 'STS' (n = 7) was submitted to food deprivation with free access to water within 48 h before imaging, and the metformin group 'MTF' (n = 7) was treated with metformin (750 mg/Kg per day) for 1 month. All mice underwent a dynamic micro-PET study for 50 min after an (18)F-FDG injection. The compartmental analysis considered two FDG pools (phosphorylated and free) in both the gut and liver. A tracer was carried into the liver by the hepatic artery and the portal vein, and tracer delivery from the gut was considered as the sole input for portal vein tracer concentration. Accordingly, both the liver and gut were characterized by two compartments and two exchange coefficients. Each one of the two two-compartment models was mathematically described by a system of differential equations, and data optimization was performed by applying a Newton algorithm to the inverse problems associated to these differential systems. All rate constants were stable in each group. The tracer coefficient from the free to the metabolized compartment in the liver was increased by STS, while it was unaltered by MTF. By contrast, the tracer coefficient from the metabolized to the free compartment was reduced by MTF and increased by STS. Data demonstrated that our method was able to analyze FDG kinetics under pharmacological or pathophysiological stimulation, quantifying the fraction of the tracer trapped in the liver or dephosphorylated and released into the bloodstream.

  15. Emission Computed Tomography: A New Technique for the Quantitative Physiologic Study of Brain and Heart in Vivo

    DOE R&D Accomplishments Database

    Phelps, M. E.; Hoffman, E. J.; Huang, S. C.; Schelbert, H. R.; Kuhl, D. E.

    1978-01-01

    Emission computed tomography can provide a quantitative in vivo measurement of regional tissue radionuclide tracer concentrations. This facility when combined with physiologic models and radioactively labeled physiologic tracers that behave in a predictable manner allow measurement of a wide variety of physiologic variables. This integrated technique has been referred to as Physiologic Tomography (PT). PT requires labeled compounds which trace physiologic processes in a known and predictable manner, and physiologic models which are appropriately formulated and validated to derive physiologic variables from ECT data. In order to effectively achieve this goal, PT requires an ECT system that is capable of performing truly quantitative or analytical measurements of tissue tracer concentrations and which has been well characterized in terms of spatial resolution, sensitivity and signal to noise ratios in the tomographic image. This paper illustrates the capabilities of emission computed tomography and provides examples of physiologic tomography for the regional measurement of cerebral and myocardial metabolic rate for glucose, regional measurement of cerebral blood volume, gated cardiac blood pools and capillary perfusion in brain and heart. Studies on patients with stroke and myocardial ischemia are also presented.

  16. Nano-graphene oxide composite for in vivo imaging

    PubMed Central

    Oh, Seo Yeong; Vilian, AT Ezhil; Lee, Ilsong; Han, Young-Kyu; Park, Jeong Hoon; Roh, Changhyun; Huh, Yun Suk

    2018-01-01

    Introduction Positron emission tomography (PET) tracers has the potential to revolutionize cancer imaging and diagnosis. PET tracers offer non-invasive quantitative imaging in biotechnology and biomedical applications, but it requires radioisotopes as radioactive imaging tracers or radiopharmaceuticals. Method This paper reports the synthesis of 18F-nGO-PEG by covalently functionalizing PEG with nano-graphene oxide, and its excellent stability in physiological solutions. Using a green synthesis route, nGO is then functionalized with a biocompatible PEG polymer to acquire high stability in PBS and DMEM. Results and discussion The radiochemical safety of 18F-nGO-PEG was measured by a reactive oxygen species and cell viability test. The biodistribution of 18F-nGO-PEG could be observed easily by PET, which suggested the significantly high sensitivity tumor uptake of 18F-nGO-PEG and in a tumor bearing CT-26 mouse compared to the control. 18F-nGO-PEG was applied successfully as an efficient radiotracer or drug agent in vivo using PET imaging. This article is expected to assist many researchers in the fabrication of 18F-labeled graphene-based bio-conjugates with high reproducibility for applications in the biomedicine field. PMID:29379283

  17. Physical and chemical processes of sulphur dioxide in the plume from an oil-fired power station.

    PubMed

    Flyger, H; Lewin, E; Thomsen, E L; Fenger, J; Lyck, E; Gryning, S E

    1977-03-01

    The Danish contribution to the EUROCOP COST 61a project is described. Work concerned the physical and chemical reactions of sulphur dioxide released from a power station. The investigation was based on the application of two tracers. Inactive, inert SF6 is used to monitor the dispersion of and deposition from the plume; it was intended to use radioactive 35SO2 to determine the degree of oxidation of sulphur released from the stack; so far, however, public reaction has prevented the use of a release of activity in field experiments. The report describes the construction and testing of airborne instruments for continuous registration of sulphur dioxide, nitrogen oxides, ozone and the tracer SF6, as well as for measurements of temperature and humidity. Sulphur samples were collected on filter paper in a specially constructed low volume air sampler, and the subsequentchemical analysis in the laboratory is described. Finally, the problem of navigation is treated. It is shown that nitrogen oxides may be used as an internal tracer in plume experiments. Preliminary experiments based on inactive analysis only indicated an overall half-life for SO2 in the plume of about half an hour.

  18. Analysis of single-hole and cross-hole tracer tests conducted at the Nye County early warning drilling program well complex, Nye County, Nevada

    USGS Publications Warehouse

    Umari, A.; Earle, J.D.; Fahy, M.F.

    2006-01-01

    As part of the effort to understand the flow and transport characteristics downgradient from the proposed high-level radioactive waste geologic repository at Yucca Mountain, Nevada, single- and cross-hole tracer tests were conducted from December 2004 through October 2005 in boreholes at the Nye County 22 well complex. The results were analyzed for transport properties using both numerical and analytical solutions of the governing advection dispersion equation. Preliminary results indicate effective flow porosity values ranging from 1.0 ?? 10-2 for an individual flow path to 2.0 ?? 10 -1 for composite flow paths, longitudinal dispersivity ranging from 0.3 to 3 m, and a transverse horizontal dispersivity of 0.03 m. Individual flow paths identified from the cross-hole testing indicate some solute diffusion into the stagnant portion of the alluvial aquifer.

  19. 26Al incorporation into the tissues of suckling rats through maternal milk

    NASA Astrophysics Data System (ADS)

    Yumoto, S.; Nagai, H.; Kobayashi, K.; Tada, W.; Horikawa, T.; Matsuzaki, H.

    2004-08-01

    Aluminium (Al) is highly neurotoxic and inhibits prenatal and postnatal development of the brain in humans and experimental animals. However, Al incorporation into the brain of sucklings through maternal milk has not yet been well clarified because Al lacks a suitable isotope for radioactive tracer experiments. Using 26Al as a tracer, we measured 26Al incorporation into the brain of suckling rats by accelerator mass spectrometry. Lactating rats were subcutaneously injected with 26AlCl3 from day 1 to day 20 postpartum. Suckling rats were weaned from day 21 postpartum. From day 5 to day 20 postpartum, the 26Al levels measured in the brain, liver, kidneys and bone of suckling rats increased significantly. After weaning, the amounts of 26Al in the liver and kidneys decreased remarkably. However, the 26Al amount in the brain had diminished only slightly up to 140 days after weaning.

  20. Modification of a medical PET scanner for PEPT studies

    NASA Astrophysics Data System (ADS)

    Sadrmomtaz, Alireza; Parker, D. J.; Byars, L. G.

    2007-04-01

    Over the last 20 years, positron emission tomography (PET) has developed as the most powerful functional imaging modality in medicine. Over the same period the University of Birmingham Positron Imaging Centre has applied PET to study engineering processes and developed the alternative technique of positron emission particle tracking (PEPT) in which a single radioactively labelled tracer particle is tracked by detecting simultaneously the pairs of back-to-back photons arising from positron/electron annihilation. Originally PEPT was performed using a pair of multiwire detectors, and more recently using a pair of digital gamma camera heads. In 2002 the Positron Imaging Centre acquired a medical PET scanner, an ECAT 931/08, previously used at Hammersmith Hospital. This scanner has been rebuilt in a flexible geometry for use in PEPT studies. This paper presents initial results from this system. Fast moving tracer particles can be rapidly and accurately located.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKenzie-Carter, M.A.; Lyon, R.E.

    This report contains information to support the Environmental Assessment for the Compact Ignition Tokamak Project (CIT) proposed for Princeton Plasma Physics Laboratory (PPPL). The assumptions and methodology used to assess the impact to members of the public from operational and accidental releases of radioactive material from the proposed CIT during the operational period of the project are described. A description of the tracer release tests conducted at PPPL by NOAA is included; dispersion values from these tests are used in the dose calculation. Radiological releases, doses, and resulting health risks are calculated. The computer code AIRDOS-EPA is used to calculatemore » the individual and population doses for routine releases; FUSCRAC3 is used to calculate doses resulting from off-normal releases where direct application of the NOAA tracer test data is not practical. Where applicable, doses are compared to regulatory limits and guidelines values. 44 refs., 5 figs., 18 tabs.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKenzie-Carter, M.A.; Lyon, R.E.; Rope, S.K.

    This report contains information to support the Environmental Assessment for the Burning Plasma Experiment (BPX) Project proposed for the Princeton Plasma Physics Laboratory (PPPL). The assumptions and methodology used to assess the impact to members of the public from operational and accidental releases of radioactive material from the proposed BPX during the operational period of the project are described. A description of the tracer release tests conducted at PPPL by NOAA is included; dispersion values from these tests are used in the dose calculations. Radiological releases, doses, and resulting health risks are calculated and summarized. The computer code AIRDOS- EPA,more » which is part of the computer code system CAP-88, is used to calculate the individual and population doses for routine releases; FUSCRAC3 is used to calculate doses resulting from off-normal releases where direct application of the NOAA tracer test data is not practical. Where applicable, doses are compared to regulatory limits and guideline values. 48 refs., 16 tabs.« less

  3. Method and apparatus to image biological interactions in plants

    DOEpatents

    Weisenberger, Andrew; Bonito, Gregory M.; Reid, Chantal D.; Smith, Mark Frederick

    2015-12-22

    A method to dynamically image the actual translocation of molecular compounds of interest in a plant root, root system, and rhizosphere without disturbing the root or the soil. The technique makes use of radioactive isotopes as tracers to label molecules of interest and to image their distribution in the plant and/or soil. The method allows for the study and imaging of various biological and biochemical interactions in the rhizosphere of a plant, including, but not limited to, mycorrhizal associations in such regions.

  4. Detection of (133)Xe from the Fukushima nuclear power plant in the upper troposphere above Germany.

    PubMed

    Simgen, Hardy; Arnold, Frank; Aufmhoff, Heinfried; Baumann, Robert; Kaether, Florian; Lindemann, Sebastian; Rauch, Ludwig; Schlager, Hans; Schlosser, Clemens; Schumann, Ulrich

    2014-06-01

    After the accident in the Japanese Fukushima Dai-ichi nuclear power plant in March 2011 large amounts of radioactivity were released and distributed in the atmosphere. Among them were also radioactive noble gas isotopes which can be used as tracers to test global atmospheric circulation models. This work presents unique measurements of the radionuclide (133)Xe from Fukushima in the upper troposphere above Germany. The measurements involve air sampling in a research jet aircraft followed by chromatographic xenon extraction and ultra-low background gas counting with miniaturized proportional counters. With this technique a detection limit of the order of 100 (133)Xe atoms in liter-scale air samples (corresponding to about 100 mBq/m(3)) is achievable. Our results provide proof that the (133)Xe-rich ground level air layer from Fukushima was lifted up to the tropopause and distributed hemispherically. Moreover, comparisons with ground level air measurements indicate that the arrival of the radioactive plume at high altitude over Germany occurred several days before the ground level plume. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Environmental radioactivity measurements and applications - Difficulties, current status and future trends

    NASA Astrophysics Data System (ADS)

    Anagnostakis, Marios J.

    2015-11-01

    For several decades natural and artificial radioactivity in the environment have been extensively studied all around the world. Nuclear accidents - mainly that of Chernobyl - have led to the development of the field of radioecology, while detector systems and techniques - with predominant that of γ-spectrometry - have been continuously developed through the years to meet researchers' needs. The study of natural radionuclides that was originally limited to 226Ra, 232Th and 40K was then extended to include radionuclides such as 234Th, 210Pb, 235U and 7Be, which allowed the study of radioactive equilibrium. Besides their importance from the radiation protection point of view, many radionuclides are also used as tracers of environmental processes, such as aerosol and transportation of air masses studies (7Be, 10Be, 22Na), soil erosion, sedimentation and geochronology (210Pb, 137Cs), marine ecosystems studies and studies related to climate change. All these studies require specialized samplings strategies and sampling preparation techniques as well as high quality measurements, while the improvement of detection limits is often of vital importance. This work is a review of environmental radioactivity measurements and applications, mainly focused in the field of γ-spectrometry, for which difficulties and limitations will be presented, together with future trends, new challenges and applications.

  6. Use of radioactive substances in diagnosis and treatment of neuroendocrine tumors

    PubMed Central

    Kjaer, Andreas; Knigge, Ulrich

    2015-01-01

    Abstract Radionuclides are needed both for nuclear medicine imaging as well as for peptide-receptor radionuclide therapy (PRRT) of neuroendocrine tumors (NET). Imaging is important in the initial diagnostic work-up and for staging NETs. In therapy planning, somatostatin receptor imaging (SRI) is used when treatment is targeted at the somatostatin receptors as with the use of somatostatin analogues or PRRT. SRI with gamma camera technique using the tracer 111In-DTPA-octreotide has for many years been the backbone of nuclear imaging of NETs. However, increasingly PET tracers for SRI are now used. 68Ga-DOTATATE, 68Ga-DOTATOC and 68Ga-DOTANOC are the three most often used PET tracers. They perform better than SPECT tracers and should be preferred. FDG-PET is well suited for visualization of most of the somatostatin receptor-negative tumors prognostic in NET patients. Also 11C-5-HTP, 18F-DOPA and 123I-MIBG may be used in NET. However, with FDG-PET and somatostatin receptor PET at hand we see limited necessity of other tracers. PRRT is an important tool in the treatment of advanced NETs causing complete or partial response in 20% and minor response or tumor stabilization in 60% with response duration of up to 3 years. Grade 3–4 kidney or bone marrow toxicity is seen in 1.5% and 9.5%, respectively, but are completely or partly reversible in most patients. 177Lu-DOTATATE seems to have less toxicity than 90Y-DOTATOC. However, until now only retrospective, non-randomized studies have been performed and the role of PRRT in treatment of NETs remains to be established. PMID:25959100

  7. Use of radioactive substances in diagnosis and treatment of neuroendocrine tumors.

    PubMed

    Kjaer, Andreas; Knigge, Ulrich

    2015-06-01

    Radionuclides are needed both for nuclear medicine imaging as well as for peptide-receptor radionuclide therapy (PRRT) of neuroendocrine tumors (NET). Imaging is important in the initial diagnostic work-up and for staging NETs. In therapy planning, somatostatin receptor imaging (SRI) is used when treatment is targeted at the somatostatin receptors as with the use of somatostatin analogues or PRRT. SRI with gamma camera technique using the tracer (111)In-DTPA-octreotide has for many years been the backbone of nuclear imaging of NETs. However, increasingly PET tracers for SRI are now used. (68)Ga-DOTATATE, (68)Ga-DOTATOC and (68)Ga-DOTANOC are the three most often used PET tracers. They perform better than SPECT tracers and should be preferred. FDG-PET is well suited for visualization of most of the somatostatin receptor-negative tumors prognostic in NET patients. Also (11)C-5-HTP, (18)F-DOPA and (123)I-MIBG may be used in NET. However, with FDG-PET and somatostatin receptor PET at hand we see limited necessity of other tracers. PRRT is an important tool in the treatment of advanced NETs causing complete or partial response in 20% and minor response or tumor stabilization in 60% with response duration of up to 3 years. Grade 3-4 kidney or bone marrow toxicity is seen in 1.5% and 9.5%, respectively, but are completely or partly reversible in most patients. (177)Lu-DOTATATE seems to have less toxicity than (90)Y-DOTATOC. However, until now only retrospective, non-randomized studies have been performed and the role of PRRT in treatment of NETs remains to be established.

  8. Radiosynthesis of N-¹¹C-Methyl-Taurine-Conjugated Bile Acids and Biodistribution Studies in Pigs by PET/CT.

    PubMed

    Schacht, Anna Christina; Sørensen, Michael; Munk, Ole Lajord; Frisch, Kim

    2016-04-01

    During cholestasis, accumulation of conjugated bile acids may occur in the liver and lead to hepatocellular damage. Inspired by our recent development of N-(11)C-methyl-glycocholic acid-that is, (11)C-cholylsarcosine-a tracer for PET of the endogenous glycine conjugate of cholic acid, we report here a radiosynthesis of N-(11)C-methyl-taurine-conjugated bile acids and biodistribution studies in pigs by PET/CT. A radiosynthesis of N-(11)C-methyl-taurine-conjugated bile acids was developed and used to prepare N-(11)C-methyl-taurine conjugates derived from cholic, chenodeoxycholic, deoxycholic, ursodeoxycholic, and lithocholic acid. The lipophilicity of these new tracers was determined by reversed-phase thin-layer chromatography. The effect of lipophilicity and structure on the biodistribution was investigated in pigs by PET/CT using the tracers derived from cholic acid (3α-OH, 7α-OH, 12α-OH), ursodeoxycholic acid (3α-OH, 7β-OH), and lithocholic acid (3α-OH). The radiosyntheses of the N-(11)C-methyl-taurine-conjugated bile acids proceeded with radiochemical yields of 61% (decay-corrected) or greater and radiochemical purities greater than 99%. PET/CT in pigs revealed that the tracers were rapidly taken up by the liver and secreted into bile. There was no detectable radioactivity in urine. Significant reflux of N-(11)C-methyl-taurolithocholic acid into the stomach was observed. We have successfully developed a radiosynthesis of N-(11)C-methyl-taurine-conjugated bile acids. These tracers behave in a manner similar to endogenous taurine-conjugated bile acids in vivo and are thus promising for functional PET of patients with cholestatic diseases. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  9. Perfusion network shift during seizures in medial temporal lobe epilepsy.

    PubMed

    Sequeira, Karen M; Tabesh, Ali; Sainju, Rup K; DeSantis, Stacia M; Naselaris, Thomas; Joseph, Jane E; Ahlman, Mark A; Spicer, Kenneth M; Glazier, Steve S; Edwards, Jonathan C; Bonilha, Leonardo

    2013-01-01

    Medial temporal lobe epilepsy (MTLE) is associated with limbic atrophy involving the hippocampus, peri-hippocampal and extra-temporal structures. While MTLE is related to static structural limbic compromise, it is unknown whether the limbic system undergoes dynamic regional perfusion network alterations during seizures. In this study, we aimed to investigate state specific (i.e. ictal versus interictal) perfusional limbic networks in patients with MTLE. We studied clinical information and single photon emission computed tomography (SPECT) images obtained with intravenous infusion of the radioactive tracer Technetium- Tc 99 m Hexamethylpropyleneamine Oxime (Tc-99 m HMPAO) during ictal and interictal state confirmed by video-electroencephalography (VEEG) in 20 patients with unilateral MTLE (12 left and 8 right MTLE). Pair-wise voxel-based analyses were used to define global changes in tracer between states. Regional tracer uptake was calculated and state specific adjacency matrices were constructed based on regional correlation of uptake across subjects. Graph theoretical measures were applied to investigate global and regional state specific network reconfigurations. A significant increase in tracer uptake was observed during the ictal state in the medial temporal region, cerebellum, thalamus, insula and putamen. From network analyses, we observed a relative decreased correlation between the epileptogenic temporal region and remaining cortex during the interictal state, followed by a surge of cross-correlated perfusion in epileptogenic temporal-limbic structures during a seizure, corresponding to local network integration. These results suggest that MTLE is associated with a state specific perfusion and possibly functional organization consisting of a surge of limbic cross-correlated tracer uptake during a seizure, with a relative disconnection of the epileptogenic temporal lobe in the interictal period. This pattern of state specific shift in metabolic networks in MTLE may improve the understanding of epileptogenesis and neuropsychological impairments associated with MTLE.

  10. Nasal high flow clears anatomical dead space in upper airway models

    PubMed Central

    Celik, Gülnaz; Feng, Sheng; Bartenstein, Peter; Meyer, Gabriele; Eickelberg, Oliver; Schmid, Otmar; Tatkov, Stanislav

    2015-01-01

    Recent studies showed that nasal high flow (NHF) with or without supplemental oxygen can assist ventilation of patients with chronic respiratory and sleep disorders. The hypothesis of this study was to test whether NHF can clear dead space in two different models of the upper nasal airways. The first was a simple tube model consisting of a nozzle to simulate the nasal valve area, connected to a cylindrical tube to simulate the nasal cavity. The second was a more complex anatomically representative upper airway model, constructed from segmented CT-scan images of a healthy volunteer. After filling the models with tracer gases, NHF was delivered at rates of 15, 30, and 45 l/min. The tracer gas clearance was determined using dynamic infrared CO2 spectroscopy and 81mKr-gas radioactive gamma camera imaging. There was a similar tracer-gas clearance characteristic in the tube model and the upper airway model: clearance half-times were below 1.0 s and decreased with increasing NHF rates. For both models, the anterior compartments demonstrated faster clearance levels (half-times < 0.5 s) and the posterior sections showed slower clearance (half-times < 1.0 s). Both imaging methods showed similar flow-dependent tracer-gas clearance in the models. For the anatomically based model, there was complete tracer-gas removal from the nasal cavities within 1.0 s. The level of clearance in the nasal cavities increased by 1.8 ml/s for every 1.0 l/min increase in the rate of NHF. The study has demonstrated the fast-occurring clearance of nasal cavities by NHF therapy, which is capable of reducing of dead space rebreathing. PMID:25882385

  11. Bone marrow uptake of 99mTc-MIBI in patients with multiple myeloma.

    PubMed

    Fonti, R; Del Vecchio, S; Zannetti, A; De Renzo, A; Di Gennaro, F; Catalano, L; Califano, C; Pace, L; Rotoli, B; Salvatore, M

    2001-02-01

    In a previous study, we showed the ability of technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) scan to identify active disease in patients with multiple myeloma (Eur J Nucl Med 1998; 25: 714-720). In particular, a semiquantitative score of the extension and intensity of bone marrow uptake was derived and correlated with both the clinical status of the disease and plasma cell bone marrow infiltration. In order to estimate quantitatively 99mTc-MIBI bone marrow uptake and to verify the intracellular localization of the tracer, bone marrow samples obtained from 24 multiple myeloma patients, three patients with monoclonal gammopathy of undetermined significance (MGUS) and two healthy donors were studied for in vitro uptake. After centrifugation over Ficoll-Hypaque gradient, cell suspensions were incubated with 99mTc-MIBI and the uptake was expressed as the percentage of radioactivity specifically retained within the cells. The cellular localization of the tracer was assessed by micro-autoradiography. Twenty-two out of 27 patients underwent 99mTc-MIBI scan within a week of bone marrow sampling. Whole-body images were obtained 10 min after intravenous injection of 555 MBq of the tracer; the extension and intensity of 99mTc-MIBI uptake were graded using the semiquantitative score. A statistically significant correlation was found between in vitro uptake of 99mTc-MIBI and both plasma cell infiltration (Pearson's coefficient of correlation r=0.69, P<0.0001) and in vivo score (Spearman rank correlation coefficient r=0.60, P<0.01). No specific tracer uptake was found in bone marrow samples obtained from the two healthy donors. Micro-autoradiography showed localization of 99mTc-MIBI inside the plasma cells infiltrating the bone marrow. Therefore, our findings show that the degree of tracer uptake both in vitro and in vivo is related to the percentage of infiltrating plasma cells which accumulate the tracer in their inner compartments.

  12. Suitability of 239+240Pu and 137Cs as tracers for soil erosion assessment in mountain grasslands.

    PubMed

    Alewell, Christine; Meusburger, Katrin; Juretzko, Gregor; Mabit, Lionel; Ketterer, Michael E

    2014-05-01

    Anthropogenic radionuclides have been distributed globally due to nuclear weapons testing, nuclear accidents, nuclear weapons fabrication, and nuclear fuel reprocessing. While the negative consequences of this radioactive contamination are self-evident, the ubiquitous fallout radionuclides (FRNs) distribution form the basis for the use as tracers in ecological studies, namely for soil erosion assessment. Soil erosion is a major threat to mountain ecosystems worldwide. We compare the suitability of the anthropogenic FRNs, 137Cs and 239+240Pu as soil erosion tracers in two alpine valleys of Switzerland (Urseren Valley, Canton Uri, Central Swiss Alps and Val Piora, Ticino, Southern Alps). We sampled reference and potentially erosive sites in transects along both valleys. 137Cs measurements of soil samples were performed with a Li-drifted Germanium detector and 239+240Pu with ICP-MS. Our data indicates a heterogeneous deposition of the 137Cs, since most of the fallout origins from the Chernobyl April/May 1986 accident, when large parts of the European Alps were still snow-covered. In contrast, 239+240Pu fallout originated mainly from 1950s to 1960s atmospheric nuclear weapons tests, resulting in a more homogenous distribution and thus seems to be a more suitable tracer in mountainous grasslands. Soil erosion assessment using 239+240Pu as a tracer pointed to a huge dynamic and high heterogeneity of erosive processes (between sedimentation of 1.9 and 7 t ha(-1) yr(-1) and erosion of 0.2-16.4 t ha(-1) yr(-1) in the Urseren Valley and sedimentation of 0.4-20.3 t ha(-1) yr(-1) and erosion of 0.1-16.4 t ha(-1) yr(-1) at Val Piora). Our study represents a novel and successful application of 239+240Pu as a tracer of soil erosion in a mountain environment. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Regional distribution and kinetics of [18F]fluciclovine (anti-[18F]FACBC), a tracer of amino acid transport, in subjects with primary prostate cancer.

    PubMed

    Sörensen, Jens; Owenius, Rikard; Lax, Michelle; Johansson, Silvia

    2013-02-01

    [(18)F]Fluciclovine (anti-[(18)F]FACBC) is a synthetic amino acid developed for PET assessment of the anabolic component of tumour metabolism in clinical routine. This phase 1 trial evaluated the safety, tracer stability and uptake kinetics of [(18)F]fluciclovine in patients. Six patients with biopsy-proven prostate cancer were investigated with 3-T MRI and PET/CT. All underwent dynamic [(18)F]fluciclovine PET/CT of the pelvic area for up to 120 min after injection of 418 ± 10 MBq of tracer with simultaneous blood sampling of radioactivity. The kinetics of uptake in tumours and normal tissues were evaluated using standardized uptake values (SUVs) and compartmental modelling. Tumour deposits as defined by MRI were clearly visualized by PET. Urine excretion was minimal and normal tissue background was low. Uptake of [(18)F]fluciclovine in tumour from the blood was rapid and the tumour-to-normal tissue contrast was highest between 1 and 15 min after injection with a 65 % reduction in mean tumour uptake at 90 min after injection. A one-compartment model fitted the tracer kinetics well. Early SUVs correlated well with both the influx rate constant (K (1)) and the volume of distribution of the tracer (V (T)). There were no signs of tracer metabolite formation. The product was well tolerated in all patients without significant adverse events. [(18)F]Fluciclovine shows high uptake in prostate cancer deposits and appears safe for use in humans. The production is robust and the formulation stable in vivo. An early imaging window seems to provide the best visual results. SUV measurements capture most of the kinetic information that can be obtained from more advanced models, potentially simplifying quantification in future studies.

  14. The determination of residence times in a pilot plant

    NASA Astrophysics Data System (ADS)

    Ramírez, F. Pablo; Cortés, M. Eugenia

    2004-01-01

    It is well known that residence time distributions (RTD) are very important in many chemical processes such as separation, reforming, hydrocracking, fluid catalytic cracking, hydrodesulfuration, hydrogenation among others [3 Procédés de transformation, Editions Technip, Institute Francais du Petrole, Paris, France, 1998]. In addition, tracers can be used to measure the velocity, distribution and residence time of any stream through any part of an industrial [Guidebook on Radioisotope Tracers in Industry, IAEA, Vienna, 1990] or experimental system. Perhaps the best quality of radiotracers is that they do not interfere with normal unit operations or production scheduling. In this paper are presented the RTDs obtained in a pilot plant for a hydrogenation process [IMP, Technical Report, Determinación del tiempo de residencia promedio en el reactor de la planta piloto de hidroagotamiento de crudo, 2002]. The RTDs show a random phenomenon, which is not typical of this type of chemical processes. Several RTDs were determined in order to confirm this random behavior. The data were obtained using as a tracer a radioactive form of sodium iodide containing iodine-131 [The Condensed Chemical Dictionary, 10th Ed., Van Nostrand Reinhold, USA, 1981]. The process works with two phases in a countercurrent flow, inside a packed column. The liquid phase goes down by gravity. The gas phase goes up due to pressure difference [3 Procédés de transformation, Editions Technip, Institute Francais du Petrole, Paris, France, 1998]. The tracer was selected such that it would follow the liquid phase.

  15. STRATEGIES FOR QUANTIFYING PET IMAGING DATA FROM TRACER STUDIES OF BRAIN RECEPTORS AND ENZYMES.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Logan, J.

    2001-04-02

    A description of some of the methods used in neuroreceptor imaging to distinguish changes in receptor availability has been presented in this chapter. It is necessary to look beyond regional uptake of the tracer since uptake generally is affected by factors other than the number of receptors for which the tracer has affinity. An exception is the infusion method producing an equilibrium state. The techniques vary in complexity some requiring arterial blood measurements of unmetabolized tracer and multiple time uptake data. Others require only a few plasma and uptake measurements and those based on a reference region require no plasmamore » measurements. We have outlined some of the limitations of the different methods. Laruelle (1999) has pointed out that test/retest studies to which various methods can be applied are crucial in determining the optimal method for a particular study. The choice of method will also depend upon the application. In a clinical setting, methods not involving arterial blood sampling are generally preferred. In the future techniques for externally measuring arterial plasma radioactivity with only a few blood samples for metabolite correction will extend the modeling options of clinical PET. Also since parametric images can provide information beyond that of ROI analysis, improved techniques for generating such images will be important, particularly for ligands requiring more than a one-compartment model. Techniques such as the wavelet transform proposed by Turkheimer et al. (2000) may prove to be important in reducing noise and improving quantitation.« less

  16. Evaluation of nitrous oxide as a substitute for sulfur hexafluoride to reduce global warming impacts of ANSI/HPS N13.1 gaseous uniformity testing

    NASA Astrophysics Data System (ADS)

    Yu, Xiao-Ying; Barnett, J. Matthew; Amidan, Brett G.; Recknagle, Kurtis P.; Flaherty, Julia E.; Antonio, Ernest J.; Glissmeyer, John A.

    2018-03-01

    The ANSI/HPS N13.1-2011 standard requires gaseous tracer uniformity testing for sampling associated with stacks used in radioactive air emissions. Sulfur hexafluoride (SF6), a greenhouse gas with a high global warming potential, has long been the gas tracer used in such testing. To reduce the impact of gas tracer tests on the environment, nitrous oxide (N2O) was evaluated as a potential replacement to SF6. The physical evaluation included the development of a test plan to record percent coefficient of variance and the percent maximum deviation between the two gases while considering variables such as fan configuration, injection position, and flow rate. Statistical power was calculated to determine how many sample sets were needed, and computational fluid dynamic modeling was utilized to estimate overall mixing in stacks. Results show there are no significant differences between the behaviors of the two gases, and SF6 modeling corroborated N2O test results. Although, in principle, all tracer gases should behave in an identical manner for measuring mixing within a stack, the series of physical tests guided by statistics was performed to demonstrate the equivalence of N2O testing to SF6 testing in the context of stack qualification tests. The results demonstrate that N2O is a viable choice leading to a four times reduction in global warming impacts for future similar compliance driven testing.

  17. Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT.

    PubMed

    Wiesmüller, Marco; Quick, Harald H; Navalpakkam, Bharath; Lell, Michael M; Uder, Michael; Ritt, Philipp; Schmidt, Daniela; Beck, Michael; Kuwert, Torsten; von Gall, Carl C

    2013-01-01

    PET/MR hybrid scanners have recently been introduced, but not yet validated. The aim of this study was to compare the PET components of a PET/CT hybrid system and of a simultaneous whole-body PET/MR hybrid system with regard to reproducibility of lesion detection and quantitation of tracer uptake. A total of 46 patients underwent a whole-body PET/CT scan 1 h after injection and an average of 88 min later a second scan using a hybrid PET/MR system. The radioactive tracers used were (18)F-deoxyglucose (FDG), (18)F-ethylcholine (FEC) and (68)Ga-DOTATATE (Ga-DOTATATE). The PET images from PET/CT (PET(CT)) and from PET/MR (PET(MR)) were analysed for tracer-positive lesions. Regional tracer uptake in these foci was quantified using volumes of interest, and maximal and average standardized uptake values (SUV(max) and SUV(avg), respectively) were calculated. Of the 46 patients, 43 were eligible for comparison and statistical analysis. All lesions except one identified by PET(CT) were identified by PET(MR) (99.2 %). In 38 patients (88.4 %), the same number of foci were identified by PET(CT) and by PET(MR). In four patients, more lesions were identified by PET(MR) than by PET(CT), in one patient PET(CT) revealed an additional focus compared to PET(MR). The mean SUV(max) and SUV(avg) of all lesions determined by PET(MR) were by 21 % and 11 % lower, respectively, than the values determined by PET(CT) (p < 0.05), and a strong correlation between these variables was identified (Spearman rho 0.835; p < 0.01). PET/MR showed equivalent performance in terms of qualitative lesion detection to PET/CT. The differences demonstrated in quantitation of tracer uptake between PET(CT) and PET(MR) were minor, but statistically significant. Nevertheless, a more detailed study of the quantitative accuracy of PET(MR) and the factors governing it is needed to ultimately assess its accuracy in measuring tissue tracer concentrations.

  18. Radioactive iodine therapy: Effect on functioning metastases of adenocarcinoma of the thyroid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seidlin, S.M.; Marinelli, L.D.; Oshry, E.

    1990-09-01

    A case of metastatic adenocarcinoma of the thyroid is reported in which treatment by means of radioactive iodine has been successful. The patient was completely thyroidectomized for malignant adenoma in 1923, with neither thyrotoxicosis then nor hypothyroidism postoperatively; 15 years later there developed classic symptoms of hyperthyroidism and severe pain in the lower back. In October 1939 a pulsating tumor removed from the level of the 12th thoracic vertebra proved to be metastatic thyroid adenocarcinoma (histologically well differentiated, with small follicles and colloid). In the next two years hyperthyroidism increased and roentgenograms revealed new metastases in the lungs, upper partmore » of the right femur, second rib on the left side, left ilium, and skull. Roentgenologic irradiation of the metastases proved ineffectual. In March 1943 a tracer dose of radioactive iodine revealed iodine retention by all the known lesions and no evidence of residual thyroid tissue in the neck. Therapeutic amounts of radioactive iodine were administered orally between May and October 1943. Definite and lasting clinical improvement followed. In April 1944 and March 1945 additional I* was administered with a resultant disappearance of pain, increase in weight, and progressive change in all clinical criteria in the direction of hypothyroidism. Roentgenographic evidence pointed to an arrest if not a regression of the disease. No untoward effects followed this therapy. Radioactive iodine seems to be an effective therapeutic agent in the control of this type of tumor.« less

  19. A quantitative method for optimized placement of continuous air monitors.

    PubMed

    Whicker, Jeffrey J; Rodgers, John C; Moxley, John S

    2003-11-01

    Alarming continuous air monitors (CAMs) are a critical component for worker protection in facilities that handle large amounts of hazardous materials. In nuclear facilities, continuous air monitors alarm when levels of airborne radioactive materials exceed alarm thresholds, thus prompting workers to exit the room to reduce inhalation exposures. To maintain a high level of worker protection, continuous air monitors are required to detect radioactive aerosol clouds quickly and with good sensitivity. This requires that there are sufficient numbers of continuous air monitors in a room and that they are well positioned. Yet there are no published methodologies to quantitatively determine the optimal number and placement of continuous air monitors in a room. The goal of this study was to develop and test an approach to quantitatively determine optimal number and placement of continuous air monitors in a room. The method we have developed uses tracer aerosol releases (to simulate accidental releases) and the measurement of the temporal and spatial aspects of the dispersion of the tracer aerosol through the room. The aerosol dispersion data is then analyzed to optimize continuous air monitor utilization based on simulated worker exposure. This method was tested in a room within a Department of Energy operated plutonium facility at the Savannah River Site in South Carolina, U.S. Results from this study show that the value of quantitative airflow and aerosol dispersion studies is significant and that worker protection can be significantly improved while balancing the costs associated with CAM programs.

  20. Tracers for fluorescence-guided surgery: how elongation of the polymethine chain in cyanine dyes alters the pharmacokinetics of a (bimodal) c[RGDyK] tracer.

    PubMed

    Buckle, Tessa; van Willigen, Danny M; Spa, Silvia J; Hensbergen, Albertus W; van der Wal, Steffen; de Korne, Clarize M; Welling, Mick M; van der Poel, Henk G; Hardwick, James C H; van Leeuwen, Fijs W B

    2018-02-15

    Objectives: The potential of (receptor-mediated) fluorescence-based image-guided surgery tracers is generally linked to the near-infrared emission profile and good manufacturing production (GMP) availability of fluorescent dyes. Surprisingly, little is known about the critical interaction between the structural composition of the dye and the pharmacokinetics of the tracers. In this study, a bimodal/hybrid tracer design was used to systematically and quantitatively evaluate the influence of elongation of the polymethine chain in a fluorescent cyanine (Cy) dye on the imaging potential of a targeted (RGD-based) tracer. Methods: As model system, the integrin marker ανβ3 was targeted using c[RGDyK] vectors functionalized with a ( 111 In-)DTPA chelate and a fluorescent dye (Cy3-(SO3)Methyl-COOH (λem 580nm), Cy5-(SO3)Methyl-COOH (λem 680nm), or Cy7-(SO3)Methyl-COOH (λem 780nm)). Tracers were analyzed for differences in (photo-) physical properties, serum protein binding, chemical/optical stability and signal penetration through tissue. Receptor affinities (KD) were evaluated using saturation and competition experiments. In vivo biodistribution (SPECT imaging and percentage injected dose per gram of tissue (%ID/g)) was assessed in tumor-bearing mice and complimented with in- and ex vivo fluorescence images obtained using a clinical grade multispectral fluorescence laparoscope. Results: Two carbon-atom-step variations in the polymethine chain of the fluorescent Cy-dyes were shown to significantly influence the chemical and photophysical characteristics e.g. stability, brightness and tissue penetration of the hybrid RGD-tracers. Herein DTPA-Cy5-(SO3)Methyl-COOH-c[RGDyK] systematically outperformed its Cy3- and Cy7- derivatives. Radioactivity-based evaluation of in vivo tracer pharmacokinetics yielded the lowest non-specific uptake and highest tumor-to-background ratio (T/B) for DTPA-Cy5-(SO3)Methyl-COOH-c[RGDyK] (13.2 ± 1.7), with the Cy3- and Cy7- analogs trailing at a respective T/B of 5.7 ± 0.7 and 4.7 ± 0.7. Fluorescence-based assessment of the tumor visibility revealed a similar trend. Conclusion: These findings underline that variations in the polymethine chain lengths of Cy dyes have a profound influence on the photophysical properties, stability and in vivo targeting capabilities of fluorescent imaging tracers. In a direct comparison the intermediate length dye (Cy5) yielded a superior c[RGDyK] -tracer compared to the shorter (Cy3-) and longer (Cy7-) analogs. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  1. Semiautomated analysis of small-animal PET data.

    PubMed

    Kesner, Adam L; Dahlbom, Magnus; Huang, Sung-Cheng; Hsueh, Wei-Ann; Pio, Betty S; Czernin, Johannes; Kreissl, Michael; Wu, Hsiao-Ming; Silverman, Daniel H S

    2006-07-01

    The objective of the work reported here was to develop and test automated methods to calculate biodistribution of PET tracers using small-animal PET images. After developing software that uses visually distinguishable organs and other landmarks on a scan to semiautomatically coregister a digital mouse phantom with a small-animal PET scan, we elastically transformed the phantom to conform to those landmarks in 9 simulated scans and in 18 actual PET scans acquired of 9 mice. Tracer concentrations were automatically calculated in 22 regions of interest (ROIs) reflecting the whole body and 21 individual organs. To assess the accuracy of this approach, we compared the software-measured activities in the ROIs of simulated PET scans with the known activities, and we compared the software-measured activities in the ROIs of real PET scans both with manually established ROI activities in original scan data and with actual radioactivity content in immediately harvested tissues of imaged animals. PET/atlas coregistrations were successfully generated with minimal end-user input, allowing rapid quantification of 22 separate tissue ROIs. The simulated scan analysis found the method to be robust with respect to the overall size and shape of individual animal scans, with average activity values for all organs tested falling within the range of 98% +/- 3% of the organ activity measured in the unstretched phantom scan. Standardized uptake values (SUVs) measured from actual PET scans using this semiautomated method correlated reasonably well with radioactivity content measured in harvested organs (median r = 0.94) and compared favorably with conventional SUV correlations with harvested organ data (median r = 0.825). A semiautomated analytic approach involving coregistration of scan-derived images with atlas-type images can be used in small-animal whole-body radiotracer studies to estimate radioactivity concentrations in organs. This approach is rapid and less labor intensive than are traditional methods, without diminishing overall accuracy. Such techniques have the possibility of saving time, effort, and the number of animals needed for such assessments.

  2. Evaluation of metabolism, plasma protein binding and other biological parameters after administration of (-)-[(18)F]Flubatine in humans.

    PubMed

    Patt, Marianne; Becker, Georg A; Grossmann, Udo; Habermann, Bernd; Schildan, Andreas; Wilke, Stephan; Deuther-Conrad, Winnie; Graef, Susanne; Fischer, Steffen; Smits, René; Hoepping, Alexander; Wagenknecht, Gudrun; Steinbach, Jörg; Gertz, Hermann-Josef; Hesse, Swen; Schönknecht, Peter; Brust, Peter; Sabri, Osama

    2014-07-01

    (-)-[(18)F]Flubatine is a PET tracer with high affinity and selectivity for the nicotinic acetylcholine α4β2 receptor subtype. A clinical trial assessing the availability of this subtype of nAChRs was performed. From a total participant number of 21 Alzheimer's disease (AD) patients and 20 healthy controls (HCs), the following parameters were determined: plasma protein binding, metabolism and activity distribution between plasma and whole blood. Plasma protein binding and fraction of unchanged parent compound were assessed by ultracentrifugation and HPLC, respectively. The distribution of radioactivity (parent compound+metabolites) between plasma and whole blood was determined ex vivo at different time-points after injection by gamma counting after separation of whole blood by centrifugation into the cellular and non-cellular components. In additional experiments in vitro, tracer distribution between these blood components was assessed for up to 90min. A fraction of 15%±2% of (-)-[(18)F]Flubatine was found to be bound to plasma proteins. Metabolic degradation of (-)-[(18)F]Flubatine was very low, resulting in almost 90% unchanged parent compound at 90min p.i. with no significant difference between AD and HC. The radioactivity distribution between plasma and whole blood changed in vivo only slightly over time from 0.82±0.03 at 3min p.i. to 0.87±0.03 at 270min p.i. indicating the contribution of only a small amount of metabolites. In vitro studies revealed that (-)-[(18)F]Flubatine was instantaneously distributed between cellular and non-cellular blood parts. (-)-[(18)F]Flubatine exhibits very favourable characteristics for a PET radiotracer such as slow metabolic degradation and moderate plasma protein binding. Equilibrium of radioactivity distribution between plasma and whole blood is reached instantaneously and remains almost constant over time allowing both convenient sample handling and facilitated fractional blood volume contribution assessment. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Estimation of aquifer radionuclide concentrations by postprocessing of conservative tracer model results

    NASA Astrophysics Data System (ADS)

    Gedeon, M.; Vandersteen, K.; Rogiers, B.

    2012-04-01

    Radionuclide concentrations in aquifers represent an important indicator in estimating the impact of a planned surface disposal for low and medium level short-lived radioactive waste in Belgium, developed by the Belgian Agency for Radioactive Waste and Enriched Fissile Materials (ONDRAF/NIRAS), who also coordinates and leads the corresponding research. Estimating aquifer concentrations for individual radionuclides represents a computational challenge because (a) different retardation values are applied to different hydrogeologic units and (b) sequential decay reactions with radionuclides of various sorption characteristics cause long computational times until a steady-state is reached. The presented work proposes a methodology reducing substantially the computational effort by postprocessing the results of a prior non-reactive tracer simulation. These advective transport results represent the steady-state concentration - source flux ratio and the break-through time at each modelling cell. These two variables are further used to estimate the individual radionuclide concentrations by (a) scaling the steady-state concentrations to the source fluxes of individual radionuclides; (b) applying the radioactive decay and ingrowth in a decay chain; (c) scaling the travel time by the retardation factor and (d) applying linear sorption. While all steps except (b) require solving simple linear equations, applying ingrowth of individual radionuclides in decay chains requires solving the differential Bateman equation. This equation needs to be solved once for a unit radionuclide activity at all arrival times found in the numerical grid. The ratios between the parent nuclide activity and the progeny activities are then used in the postprocessing. Results are presented for discrete points and examples of radioactive plume maps are given. These results compare well to the results achieved using a full numerical simulation including the respective chemical reaction processes. Although the proposed method represents a fast way to estimate the radionuclide concentrations without performing timely challenging simulations, its applicability has some limits. The radionuclide source needs to be assumed constant during the period of achieving a steady-state in the model. Otherwise, the source variability of individual radionuclides needs to be modelled using a numerical simulation. However, such a situation only occurs in cases of source variability in a period until steady-state is reached and such a simulation takes a relatively short time. The proposed method enables an effective estimation of individual radionuclide concentrations in the frame of performance assessment of a radioactive waste disposal. Reducing the calculation time to a minimum enables performing sensitivity and uncertainty analyses, testing alternative models, etc. thus enhancing the overall quality of the modelling analysis.

  4. Preparation and Characterization of Hyaluronic Acid-Polycaprolactone Copolymer Micelles for the Drug Delivery of Radioactive Iodine-131 Labeled Lipiodol.

    PubMed

    Chen, Shih-Cheng; Yang, Ming-Hui; Chung, Tze-Wen; Jhuang, Ting-Syuan; Yang, Jean-Dean; Chen, Ko-Chin; Chen, Wan-Jou; Huang, Ying-Fong; Jong, Shiang-Bin; Tsai, Wan-Chi; Lin, Po-Chiao; Tyan, Yu-Chang

    2017-01-01

    Micelles, with the structure of amphiphilic molecules including a hydrophilic head and a hydrophobic tail, are recently developed as nanocarriers for the delivery of drugs with poor solubility. In addition, micelles have shown many advantages, such as enhanced permeation and retention (EPR) effects, prolonged circulation times, and increased endocytosis through surface modification. In this study, we measured the critical micelle concentrations, diameters, stability, and cytotoxicity and the cell uptake of micelles against hepatic cells with two kinds of hydrophilic materials: PEG-PCL and HA-g-PCL. We used 131 I as a radioactive tracer to evaluate the stability, drug delivery, and cell uptake activity of the micelles. The results showed that HA-g-PCL micelles exhibited higher drug encapsulation efficiency and stability in aqueous solutions. In addition, the 131 I-lipiodol loaded HA-g-PCL micelles had better affinity and higher cytotoxicity compared to HepG2 cells.

  5. Quantitative imaging of disease signatures through radioactive decay signal conversion

    PubMed Central

    Thorek, Daniel LJ; Ogirala, Anuja; Beattie, Bradley J; Grimm, Jan

    2013-01-01

    In the era of personalized medicine there is an urgent need for in vivo techniques able to sensitively detect and quantify molecular activities. Sensitive imaging of gamma rays is widely used, but radioactive decay is a physical constant and signal is independent of biological interactions. Here we introduce a framework of novel targeted and activatable probes excited by a nuclear decay-derived signal to identify and measure molecular signatures of disease. This was accomplished utilizing Cerenkov luminescence (CL), the light produced by β-emitting radionuclides such as clinical positron emission tomography (PET) tracers. Disease markers were detected using nanoparticles to produce secondary Cerenkov-induced fluorescence. This approach reduces background signal compared to conventional fluorescence imaging. In addition to information from a PET scan, we demonstrate novel medical utility by quantitatively determining prognostically relevant enzymatic activity. This technique can be applied to monitor other markers and facilitates a shift towards activatable nuclear medicine agents. PMID:24013701

  6. [Phosphorus transfer between mixed poplar and black locust seedlings].

    PubMed

    He, Wei; Jia, Liming; Hao, Baogang; Wen, Xuejun; Zhai, Mingpu

    2003-04-01

    In this paper, the 32P radio-tracer technique was applied to study the ways of phosphorus transfer between poplar (Populus euramericana cv. 'I-214') and black locust (Robinia pseudoacacia). A five compartment root box (18 cm x 18 cm x 26 cm) was used for testing the existence of the hyphal links between the roots of two tree species when inoculated with vesicular-arbuscular (VA) mycorrhizal fungus (Glomus mosseae). Populus I-214 (donor) and Robinia pseudoacacia (receiver) were grown in two terminal compartments, separated by a 2 cm root-free soil layer. The root compartments were lined with bags of nylon mesh (38 microns) that allowed the passage of hyphae but not roots. The top soil of a mixed stand of poplar and black locust, autoclaved at 121 degrees C for one hour, was used for growing seedlings for testing. In 5 compartment root box, mycorrhizal root colonization of poplar was 34%, in which VA mycorrhizal fungus was inoculated, whereas 26% mycorrhizal root colonization was observed in black locust, the other terminal compartment, 20 weeks after planting. No root colonization was observed in non-inoculated plant pairs. This indicated that the mycorrhizal root colonization of black locust was caused by hyphal spreading from the poplar. Test of tracer isotope of 32P showed that the radioactivity of the treatment significantly higher than that of the control (P < 0.05), 14 days from the tracer applied, to 27 days after, when VA mycorrhizal fungus was inoculated in poplar root. Furthermore, mycorrhizal interconnections between the roots of poplar and black locust seedlings was observed in situ by binocular in root box. All these experiments showed that the hyphal links was formed between the roots of two species of trees inoculated by VA mycorrhizal fungus. Four treatments were designed according to if there were two nets (mesh 38 microns), 2 cm apart, between the poplar and black locust, and if the soil in root box was pasteurized. Most significant differences of radioactivity among four treatments appeared 44 days after feeding 32P, the radioactivity of the day was applied to estimating the contribution of the various possible transfer ways to the total amount of nutrient transfer. Level of 32P radioactivity was found to be significantly (P < 0.05) higher in leaves of the treatment of "no separated and soil non-pasteurized" (17.1 pulse.g-1.s-1) than in leaves of "net separated and soil non-pasteurized" (5.3 pulse.g-1.s-1), and also significantly higher in leaves of "no net separated and soil pasteurized" (11.5 pulse.g.s-1) than in leaves of "net separated and soil pasteurized" (2.3 pulse.g-1.s-1), and very significantly (P < 0.01) higher in leaves of "no net separated and soil non-pasteurized" than in leaves of "net separated and soil pasteurized", whereas the levels of 32P radioactivity were not significantly different between the other treatments. The results showed that root contact and root exudations were the main ways of phosphorus transfer between the two species and the amount of phosphorus transfer through these two ways accounted for 62% of the total. The activity of the microorganisms including VA mycorrhizal fungi and the interaction between the microorganisms and root contact and root exudations made up 38% of total amount of phosphorus. The effect of mycorrhizal hyphal links in the direct nutrient transfer between poplar and black locust through separate mesh (38 microns) was little.

  7. Standardization of fluorine-18 manufacturing processes: new scientific challenges for PET.

    PubMed

    Hjelstuen, Ole K; Svadberg, Anders; Olberg, Dag E; Rosser, Mark

    2011-08-01

    In [(18)F]fluoride chemistry, the minute amounts of radioactivity taking part in a radiolabeling reaction are easily outnumbered by other reactants. Surface areas become comparably larger and more influential than in standard fluorine chemistry, while leachables, extractables, and other components that normally are considered small impurities can have a considerable influence on the efficiency of the reaction. A number of techniques exist to give sufficient (18)F-tracer for a study in a pre-clinical or clinical system, but the chemical and pharmaceutical understanding has significant gaps when it comes to scaling up or making the reaction more efficient. Automation and standardization of [(18)F]fluoride PET tracers is a prerequisite for reproducible manufacturing across multiple PET centers. So far, large-scale, multi-site manufacture has been established only for [(18)F]FDG, but several new tracers are emerging. In general terms, this transition from small- to large-scale production has disclosed several scientific challenges that need to be addressed. There are still areas of limited knowledge in the fundamental [(18)F]fluoride chemistry. The role of pharmaceutical factors that could influence the (18)F-radiosynthesis and the gaps in precise chemistry knowledge are discussed in this review based on a normal synthesis pattern. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Bringing physiology into PET of the liver.

    PubMed

    Keiding, Susanne

    2012-03-01

    Several physiologic features make interpretation of PET studies of liver physiology an exciting challenge. As with other organs, hepatic tracer kinetics using PET is quantified by dynamic recording of the liver after the administration of a radioactive tracer, with measurements of time-activity curves in the blood supply. However, the liver receives blood from both the portal vein and the hepatic artery, with the peak of the portal vein time-activity curve being delayed and dispersed compared with that of the hepatic artery. The use of a flow-weighted dual-input time-activity curve is of importance for the estimation of hepatic blood perfusion through initial dynamic PET recording. The portal vein is inaccessible in humans, and methods of estimating the dual-input time-activity curve without portal vein measurements are being developed. Such methods are used to estimate regional hepatic blood perfusion, for example, by means of the initial part of a dynamic (18)F-FDG PET/CT recording. Later, steady-state hepatic metabolism can be assessed using only the arterial input, provided that neither the tracer nor its metabolites are irreversibly trapped in the prehepatic splanchnic area within the acquisition period. This is used in studies of regulation of hepatic metabolism of, for example, (18)F-FDG and (11)C-palmitate.

  9. AMS measurements of 14C and 129I in seawater around radioactive waste dump sites

    NASA Astrophysics Data System (ADS)

    Povinec, P. P.; Oregioni, B.; Jull, A. J. T.; Kieser, W. E.; Zhao, X.-L.

    2000-10-01

    According to a recent IAEA compilation of inventories of radioactive wastes dumped in the world ocean, a total of 85 PBq of radioactive wastes were dumped, in the Atlantic (45 PBq), the Pacific (1.4 PBq) and the Arctic (38 PBq) Oceans and their marginal seas between 1946 and 1993, mostly in the form of low-level wastes. 3H, and 14C formed an important part of the beta-activity of these dumped wastes. Because of its long half-life, 14C will be the main constituent in possible leakages from the wastes in the future. On the other hand, 14C and 129I are important radioactive tracers which have been artificially introduced into the oceans. Small amounts of 14C and 129I can be easily measured by accelerator mass spectrometry (AMS) on mg-size samples of carbon and iodine extracted from 500 ml seawater samples. The high analytical sensitivity enables one therefore to find even trace amounts of 14C and 129I which could be released from radioactive wastes, and to compare the measured levels with the global distribution of these radionuclides. The IAEAs Marine Environment Laboratory (IAEA-MEL) has been engaged in an assessment program related to radioactive waste dumping in the oceans since 1992 and has participated in several expeditions to the Atlantic, Arctic, Indian and Pacific Oceans to sample seawater, biota and sediment for radiological assessment studies. In the present paper, we report on methods of 14C and 129I measurements in seawater by AMS and present data on the NE Atlantic, the Arctic and the NW Pacific Ocean dumping sites. A small increase of 14C was observed at the NE Atlantic dumping site.

  10. Optimum Value of Original Events on the Pept Technique

    NASA Astrophysics Data System (ADS)

    Sadremomtaz, Alireza; Taherparvar, Payvand

    2011-12-01

    Do Positron emission particle tracking (PEPT) has been used to track the motion of a single radioactively labeled tracer particle within a bed of similar particles. In this paper, the effect of the original event fraction on the results precise in two experiments has been reviewed. Results showed that the algorithm can no longer distinguish some corrupt trajectories, in addition to; further iteration reduces the statistical significance of the sample without improving its quality. Results show that the optimum value of trajectories depends on the type of experiment.

  11. Constraining Circulation Changes Through the Last Deglaciation with Deep-sea Coral Radiocarbon and Sedimentary Pa231/Th230

    DTIC Science & Technology

    2012-02-01

    et al. (2002), U-Th dating of marine isotope stage 7 in Bahamas slope sediments, Earth and Planetary Science Letters, 196(3-4), Pii S0012- 821x(01...and radioisotope studies, Earth Planet. Sci. Lett., 32(2), 420–429, doi:10.1016/ 0012-821X(76)90082-0. Krishnaswami, S., M. M. Sarin, and B. L. K...degree of Doctor of Philosophy ABSTRACT Radioactive isotopes can be used in paleoceanography both for dating samples and as tracers of ocean

  12. Improved methods for measuring radioactive tracer accumulation and excretion by microarthropods, with applications for a mite species, Tyrophagus longior (Acarina, Acaridae)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abbott, D T; Crossley, Jr, D A

    1980-08-01

    Radioisotope retention measurements of /sup 85/Sr and /sup 51/Cr in Tyrophagus longior (Gervais) (Acari: Acaridae) were fit to 2 and 1 component models. Biological half-life for the rapid component of both radioisotopes was about 10 hours, with assimilation of /sup 85/Sr being 62%. The identification of /sup 51/Cr turnover as gut clearance must remain tentative. An inexpensive disposable culture chamber for measuring radioisotope retention in microarthropods is described along with details of methodology.

  13. Standardization of 237Np by the CIEMAT/NIST LSC tracer method

    PubMed

    Gunther

    2000-03-01

    The standardization of 237Np presents some difficulties: several groups of alpha, beta and gamma radiation, chemical problems with the daughter nuclide 233Pa, an incomplete radioactive equilibrium after sample preparation, high conversion of some gamma transitions. To solve the chemical problems, a sample composition involving the Ultima Gold AB scintillator and a high concentration of HCl is used. Standardization by the CIEMAT/NIST method and by pulse shape discrimination is described. The results agree within 0.1% with those obtained by two other methods.

  14. Introduction of Total Variation Regularization into Filtered Backprojection Algorithm

    NASA Astrophysics Data System (ADS)

    Raczyński, L.; Wiślicki, W.; Klimaszewski, K.; Krzemień, W.; Kowalski, P.; Shopa, R. Y.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B.; Jasińska, B.; Kisielewska-Kamińska, D.; Korcyl, G.; Kozik, T.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Pawlik-Niedźwiecka, M.; Niedźwiecki, S.; Pałka, M.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Zgardzińska, B.; Zieliński, M.; Moskal, P.

    In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image of radioactive tracer distribution using standard Derenzo-type phantom. We demonstrate that the proposed approach results in higher cross-correlation values with respect to the standard FBP method.

  15. The Path of Carbon in Photosynthesis IX. Photosynthesis, Photoreduction, and the Hydrogen-Oxygen-Carbon Dioxide Dark Reaction

    DOE R&D Accomplishments Database

    Badin, E. J.; Calvin, M.

    1950-02-01

    A comparison of the rates of fixation of Carbon 14 dioxide in algae for the processes of photosynthesis, photoreduction and the hydrogen-oxygen-carbon dioxide dark reaction has been made. For the same series of experiments, rates of incorporation of tracer carbon into the separate soluble components using the radiogram method have been determined. The mechanism of carbon dioxide uptake has been shown to occur via two distinct paths. In all cases studied, essentially the same compounds appear radioactive. The distribution with time, however, differs markedly.

  16. Radioactive iodine therapy in cats with hyperthyroidism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turrel, J.M.; Feldman, E.C.; Hays, M.

    Eleven cats with hyperthyroidism were treated with radioactive iodine (/sup 131/I). Previous unsuccessful treatments for hyperthyroidism included hemithyroidectomy (2 cats) and an antithyroid drug (7 cats). Two cats had no prior treatment. Thyroid scans, using technetium 99m, showed enlargement and increased radionuclide accumulation in 1 thyroid lobe in 5 cats and in both lobes in 6 cats. Serum thyroxine concentrations were high and ranged from 4.7 to 18 micrograms/dl. Radioactive iodine tracer studies were used to determine peak radioactive iodine uptake (RAIU) and effective and biological half-lives. Activity of /sup 131/I administered was calculated from peak RAIU, effective half-life, andmore » estimated thyroid gland weight. Activity of /sup 131/I administered ranged from 1.0 to 5.9 mCi. The treatment goal was to deliver 20,000 rad to hyperactive thyroid tissue. However, retrospective calculations based on peak RAIU and effective half-life obtained during the treatment period showed that radiation doses actually ranged from 7,100 to 64,900 rad. Complete ablation of the hyperfunctioning thyroid tissue and a return to euthyroidism were seen in 7 cats. Partial responses were seen in 2 cats, and 2 cats became hypothyroid. It was concluded that /sup 131/I ablation of thyroid tumors was a reasonable alternative in the treatment of hyperthyroidism in cats. The optimal method of dosimetry remains to be determined.« less

  17. Uptake of hexanitrohexaazaisowurtzitane (CL-20) by the earthworm Eisenia fetida through dermal contact.

    PubMed

    Gong, Ping; Escalon, B Lynn; Hayes, Charolett A; Perkins, Edward J

    2008-02-01

    The explosive compound hexanitrohexaazaisowurtzitane (CL-20) has been shown to cause both lethal and sublethal (reproductive and neurotoxic) effects in exposed oligochaetes. However, whether worms take up CL-20 and how much CL-20 enters worm bodies leading to toxicity (e.g., lethality) remain to be determined. In the present study, we used high performance liquid chromatography (HPLC) and radiolabeled tracer methods to investigate the CL-20 uptake in the whole worm body after contact exposures. Worms (Eisenia fetida) were exposed to filter paper spiked with non-radioactive or [U-(14)C]-labeled CL-20 for 1-3 d. The radiolabeled tracer method allowed us to detect the parent compound and transformation products in worms exposed to as low as 0.04 microg CL-20 cm(-2) of filter paper. The HPLC method without radiolabeled tracer was far less sensitive with a detection limit of 2.17 microg CL-20 cm(-2). Using the radiolabeled tracer, we were able to demonstrate that the worm body concentration linearly correlated to the filter paper concentration < or =0.34 microg cm(-2) (r=0.94) if no breakdown products are assumed. At higher concentrations, the body concentration increased slowly and saturated at around 11 microg g(-1) dry mass resulting in an estimated lethal critical body burden of 10-15 microg CL-20 g(-1) dry mass. These findings demonstrate that CL-20 or potential transformation products are taken into the earthworm body through dermal contact. This information should prove valuable in assessing the bioaccumulation potential and ecological risks of CL-20.

  18. Evaluation of nitrous oxide as a substitute for sulfur hexafluoride to reduce global warming impacts of ANSI/HPS N13.1 gaseous uniformity testing

    DOE PAGES

    Yu, Xiao-Ying; Barnett, J. Matthew; Amidan, Brett G.; ...

    2017-12-12

    The ANSI/HPS N13.1–2011 standard requires gaseous tracer uniformity testing for sampling associated with stacks used in radioactive air emissions. Sulfur hexafluoride (SF 6), a greenhouse gas with a high global warming potential, has long been the gas tracer used in such testing. To reduce the impact of gas tracer tests on the environment, nitrous oxide (N 2O) was evaluated as a potential replacement to SF 6. The physical evaluation included the development of a test plan to record percent coefficient of variance and the percent maximum deviation between the two gases while considering variables such as fan configuration, injection position,more » and flow rate. Statistical power was calculated to determine how many sample sets were needed, and computational fluid dynamic modeling was utilized to estimate overall mixing in stacks. Results show there are no significant differences between the behaviors of the two gases, and SF 6 modeling corroborated N 2O test results. Although, in principle, all tracer gases should behave in an identical manner for measuring mixing within a stack, the series of physical tests guided by statistics was performed to demonstrate the equivalence of N 2O testing to SF 6 testing in the context of stack qualification tests. In conclusion, the results demonstrate that N 2O is a viable choice leading to a four times reduction in global warming impacts for future similar compliance driven testing.« less

  19. Evaluation of nitrous oxide as a substitute for sulfur hexafluoride to reduce global warming impacts of ANSI/HPS N13.1 gaseous uniformity testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Xiao-Ying; Barnett, J. Matthew; Amidan, Brett G.

    The ANSI/HPS N13.1–2011 standard requires gaseous tracer uniformity testing for sampling associated with stacks used in radioactive air emissions. Sulfur hexafluoride (SF 6), a greenhouse gas with a high global warming potential, has long been the gas tracer used in such testing. To reduce the impact of gas tracer tests on the environment, nitrous oxide (N 2O) was evaluated as a potential replacement to SF 6. The physical evaluation included the development of a test plan to record percent coefficient of variance and the percent maximum deviation between the two gases while considering variables such as fan configuration, injection position,more » and flow rate. Statistical power was calculated to determine how many sample sets were needed, and computational fluid dynamic modeling was utilized to estimate overall mixing in stacks. Results show there are no significant differences between the behaviors of the two gases, and SF 6 modeling corroborated N 2O test results. Although, in principle, all tracer gases should behave in an identical manner for measuring mixing within a stack, the series of physical tests guided by statistics was performed to demonstrate the equivalence of N 2O testing to SF 6 testing in the context of stack qualification tests. In conclusion, the results demonstrate that N 2O is a viable choice leading to a four times reduction in global warming impacts for future similar compliance driven testing.« less

  20. Wear Measurement of Highly Cross-Linked UHMWPE Using a 7Be Tracer Implantation Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wimmer, Markus; Laurent, Michael P.; Dwivedi, Yash

    2013-01-29

    The very low wear rates achieved with the current highly cross-linked ultra-high molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are therefore being explored. The purpose of this study was to effect a proof-of-concept on the use of the radioactive tracer beryllium-7 (7Be) for the determination of wear in a highly cross-linked orthopedic UHMWPE. Three crosslinked and four conventional UHMWPE pins made from compression-molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenous distribution of implanted nuclei upmore » to 8.5 μm below the surface. The pins were tested for wear in a six-station pin-on-flat apparatus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and estimated to be 17 ± 3 μg/Mc. The conventional-to-cross-linked ratio of the wear rates was 13.1 ± 0.8, in the expected range for these materials. It was estimated that implantation reduced the average wear rate by approximately 20%, and the oxidative degradation damage from implantation was negligible. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.« less

  1. Pharmacokinetics Application in Biophysics Experiments

    NASA Astrophysics Data System (ADS)

    Millet, Philippe; Lemoigne, Yves

    Among the available computerised tomography devices, the Positron Emission Tomography (PET) has the advantage to be sensitive to pico-molar concentrations of radiotracers inside living matter. Devices adapted to small animal imaging are now commercially available and allow us to study the function rather than the structure of living tissues by in vivo analysis. PET methodology, from the physics of electron-positron annihilation to the biophysics involved in tracers, is treated by other authors in this book. The basics of coincidence detection, image reconstruction, spatial resolution and sensitivity are discussed in the paper by R. Ott. The use of compartment analysis combined with pharmacokinetics is described here to illustrate an application to neuroimaging and to show how parametric imaging can bring insight on the in vivo bio-distribution of a radioactive tracer with small animal PET scanners. After reporting on the use of an intracerebral β+ radiosensitive probe (βP), we describe a small animal PET experiment used to measure the density of 5HT 1 a receptors in rat brain.

  2. [Precarious matters. The radium economy, episteme of risk and the emergence of tracer technique in national socialism].

    PubMed

    von Schwerin, Alexander

    2009-01-01

    Following the traces of radioactive material is--as scholars have recently shown--a valuable historical approach in order to evaluate the material 'factor' of science in action. Even though the origins of materials like radium and artificial isotopes are quite different, their circulation is interconnected. A material pathway can be drawn from the radium industry to the scientific rise of artificial isotopes as indicator substances in the 1930s, continuing to the building of networks by German scientists working for the war efforts. Also, this pathway reveals the role of radiation protection in establishing that material culture. Finally, the dynamics of material traces and institutional linkages is shown by the tracer work of biophysicists and radiation biologists working at the Genetic Department of the Kaiser Wilhelm Institute for Brain Research in Berlin and at the Institut de Chimie Nucléaire at Paris, which at that time was occupied by German troops.

  3. beta-Methyl-15-p-iodophenylpentadecanoic acid metabolism and kinetics in the isolated rat heart.

    PubMed

    DeGrado, T R; Holden, J E; Ng, C K; Raffel, D M; Gatley, S J

    1989-01-01

    The use of 15-p-iodophenyl-beta-methyl-pentadecanoic acid (beta Me-IPPA) as an indicator of long chain fatty acid (LCFA) utilization in nuclear medicine studies was evaluated in the isolated, perfused, working rat heart. Time courses of radioactivity (residue curves) were obtained following bolus injections of both beta Me-IPPA and its straight chain counterpart 15-p-iodophenyl-pentadecanoic acid (IPPA). IPPA kinetics clearly indicated flow independent impairment of fatty acid oxidation caused by the carnitine palmitoyltransferase I inhibitor 2[5(4-chlorophenyl)pentyl]oxirane-2-carboxylate (POCA). In contrast, beta Me-IPPA kinetics were insensitive to changes in fatty acid oxidation rate and net utilization of long chain fatty acid. Analysis of radiolabeled species in coronary effluent and heart homogenates showed the methylated fatty acid to be readily incorporated into complex lipids but a poor substrate for oxidation. POCA did not significantly alter metabolism of the tracer, suggesting that the tracer is poorly metabolized beyond beta Me-IPPA-CoA in the oxidative pathway.

  4. Radiological issues associated with the recent boom in oil and gas hydraulic fracturing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopez, Alejandro

    As the worldwide hydraulic fracturing 'fracking' market continued to grow to an estimated $37 Billion in 2012, the need to understand and manage radiological issues associated with fracking is becoming imperative. Fracking is a technique that injects pressurized fluid into rock layer to propagate fractures that allows natural gas and other petroleum products to be more easily extracted. Radioactivity is associated with fracking in two ways. Radioactive tracers are frequently a component of the injection fluid used to determine the injection profile and locations of fractures. Second, because there are naturally-occurring radioactive materials (NORM) in the media surrounding and containingmore » oil and gas deposits, the process of fracking can dislodge radioactive materials and transport them to the surface in the wastewater and gases. Treatment of the wastewater to remove heavy metals and other contaminates can concentrate the NORM into technologically-enhanced NORM (TENORM). Regulations to classify, transport, and dispose of the TENORM and other radioactive waste can be complicated and cumbersome and vary widely in the international community and even between states/provinces. In many cases, regulations on NORM and TENORM do not even exist. Public scrutiny and regulator pressure will only continue to increase as the world demands on oil and gas continue to rise and greater quantities of TENORM materials are produced. Industry experts, health physicists, regulators, and public communities must work together to understand and manage radiological issues to ensure reasonable and effective regulations protective of the public, environment, and worker safety and health are implemented. (authors)« less

  5. Early Renal Changes in 45° Hdt Rats

    NASA Astrophysics Data System (ADS)

    R. Pettis, Chris; Drake, Matt; Witten, Mark L.; Truitt, Jill; Braun, Eldon; Lindberg, Kim; McNeil, George; Hall, Jack N.

    Background: Both microgravity and simulated microgravity models, such as the 45HDT (45 ∘ head-down tilt), cause a redistribution of body fluids indicating a possible adaptive process to the microgravity stressor. Understanding the physiological processes that occur in microgravity is a first step to developing countermeasures to stop its harmful effects, i.e., (edema, motion sickness) during long-term space flights. Hypothesis: Because of the kidneys' functional role in the regulation of fluid volume in the body, it plays a key role in the body's adaptation to microgravity. Methods: Rats were injected intramuscularly with a radioactive tracer and then lightly anesthetized in order to facilitate their placement in the 45HDT position. They were then placed in the 45HDT position using a specially designed ramp (45HDT group) or prone position (control group) for an experimental time period of 1 h. During this period, the 99mTc-DTPA (technetium-labeled diethylenepentaacetate, MW=492 amu, physical half-life of 6.02 h) radioactive tracer clearance rate was determined by measuring gamma counts per minute. The kidneys were then fixed and sectioned for electron microscopy. A point counting method was used to quantitate intracellular spaces of the kidney proximal tubules. Results: 45HDT animals show a significantly ( p=0.0001) increased area in the interstitial space of the proximal tubules. Conclusions: There are significant changes in the kidneys during a 1 h exposure to a simulated microgravity environment that consist primarily of anatomical alterations in the kidney proximal tubules. The kidneys also appear to respond differently to the initial periods of head-down tilt.

  6. Sorption of radioactive contaminants by sediment from the Kara Sea

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fuhrmann, M.; Zhou, H.; Neiheisel, J.

    1995-02-01

    The purpose of this study is to quantify some of the parameters needed to perform near-field modeling of sites in the Kara Sea that were impacted by the disposal of radioactive waste. The parameters of interest are: the distribution coefficients (K{sub d}) for several important radionuclides, the mineralogy of the sediment, and the relationship of K{sub d} to liquid to solid ratio. Sediment from the Kara Sea (location: 73{degrees} 00` N, 58{degrees} 00` E) was sampled from a depth of 287 meters on August 23/24, 1992, during a joint Russian/Norwegian scientific cruise. Analysis of the material included mineralogy, grain sizemore » and total organic carbon. Uptake kinetics were determined for {sup 85}Sr, {sup 99}Tc, {sup 125}I, {sup 137}Cs, {sup 210}Pb, {sup 232}U, and {sup 241}Am and distribution coefficients (K{sub d}) were determined for these radionuclides using batch type experiments. Sorption isotherms were developed for {sup 85}Sr, {sup 99}Tc, and {sup 137}Cs to examine the effect that varying the concentration of a tracer has on the quantity of that tracer taken up by the solid. The effect of liquid to solid ratio on the uptake of contaminants was determined for {sup 99}Tc and {sup 137}Cs. In another set of experiments, the sediment was separated into four size fractions and uptake was determined for each fraction for {sup 85}Sr, {sup 99}Tc, and {sup 137}Cs. In addition, the sediment was analyzed to determine if it contains observable concentrations of anthropogenic radionuclides.« less

  7. The Path of Carbon in Photosynthesis XV. Ribulose and Sedoheptulose

    DOE R&D Accomplishments Database

    Benson, A. A.; Bassham, J. A.; Calvin, M.; Hall, A. G.; Hirsch, H.; Kawaguchi, S.; Lynch, V.; Tolbert, N. E.

    1952-01-01

    The intermediates of carbon dioxide reduction by plants include phosphorylated derivatives of hydroxy acids and sugars. Their identification became possible when the use of labeled carbon dioxide permitted discrimination between the earliest products and the many other components of photosynthetic tissues. A number of compounds were identified by virtue of the chemical and physical properties of the radioactive compounds in tracer amounts and by direct comparison of these properties with those of suspected known metabolic intermediates. It became apparent that several labeled compounds found in short exposures to radioactive carbon dioxide were not substances previously identified as metabolic intermediates. Two phosphate esters in particular were observed in the products of the first few seconds of steady-state photosynthesis by all the photosynthetic microorganisms and higher plants examined in this laboratory. These esters have been isolated by paper chromatography in tracer quantities and enzymatically hydrolyzed to give two sugars, ribulose and sedoheptulose. This paper contains a description of the chemical identification of these sugars and some observations and suggestions regarding the function of their esters. The general importance of these compounds in photosynthesis was summarized before their identification. The products of photosynthesis with C{sup 14}O{sub 2} by each plant included phosphate esters of the same two then unknown compounds in addition to those of the expected glucose, fructose, dihydroxyacetone and glyceric acid. As the time of steady-state photosynthesis in C{sup 14}O{sub 2} decreased, the fractions of total fixed radiocarbon in the esters of the two unidentified compounds increased.

  8. In vivo evaluation of [18F]FEAnGA-Me: a PET tracer for imaging β-glucuronidase (β-GUS) activity in a tumor/inflammation rodent model.

    PubMed

    Antunes, Inês F; Haisma, Hidde J; Elsinga, Philip H; Sijbesma, Jurgen W A; Waarde, Aren van; Willemsen, Antoon T M; Dierckx, Rudi A; de Vries, Erik F J

    2012-08-01

    The PET tracer, 1-O-(4-(2-fluoroethyl-carbamoyloxymethyl)-2-nitrophenyl)-O-β-d-glucopyronuronate ([(18)F]FEAnGA), was recently developed for PET imaging of extracellular β-glucuronidase (β-GUS). However, [(18)F]FEAnGA exhibited rapid renal clearance, which resulted in a relatively low tracer uptake in the tumor. To improve the pharmacokinetics of [(18)F]FEAnGA, we developed its more lipophilic methyl ester analog, [(18)F]FEAnGA-Me. [(18)F]FEAnGA-Me was obtained by alkylation of the O-protected glucuronide methyl ester precursor with [(18)F]-fluoroethylamine ([(18)F]FEA), followed by removal of the acetate protecting groups with NaOMe/MeOH. The PET tracer was evaluated by in vitro and in vivo studies. [(18)F]FEAnGA-Me was obtained in 5%-10% overall radiochemical yield. It is 10-fold less hydrophilic than [(18)F]FEAnGA and it is stable in PBS and in the presence of β-GUS for 1 h. However, in the presence of esterase or plasma [(18)F]FEAnGA-Me is converted to [(18)F]FEAnGA, and subsequently converted to [(18)F]FEA by β-GUS. MicroPET studies in Wistar rats bearing a C6 glioma and a sterile inflammation showed similar uptake in tumors after injection of either [(18)F]FEAnGA-Me or [(18)F]FEAnGA. Both tracers had a rapid two-phase clearance of total plasma radioactivity with a half-life of 1 and 8 min. The [(18)F]FEAnGA fraction generated from [(18)F]FEAnGA-Me by in vivo hydrolysis had a circulation half-life of 1 and 11 min in plasma. Similar distribution volume in the viable part of the tumor was found after injection of either [(18)F]FEAnGA-Me or [(18)F]FEAnGA. The imaging properties of [(18)F]FEAnGA-Me were not significantly better than those of [(18)F]FEAnGA. Therefore, other strategies should be applied in order to improve the kinetics of these tracers. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Quantitative Functional Imaging Using Dynamic Positron Computed Tomography and Rapid Parameter Estimation Techniques

    NASA Astrophysics Data System (ADS)

    Koeppe, Robert Allen

    Positron computed tomography (PCT) is a diagnostic imaging technique that provides both three dimensional imaging capability and quantitative measurements of local tissue radioactivity concentrations in vivo. This allows the development of non-invasive methods that employ the principles of tracer kinetics for determining physiological properties such as mass specific blood flow, tissue pH, and rates of substrate transport or utilization. A physiologically based, two-compartment tracer kinetic model was derived to mathematically describe the exchange of a radioindicator between blood and tissue. The model was adapted for use with dynamic sequences of data acquired with a positron tomograph. Rapid estimation techniques were implemented to produce functional images of the model parameters by analyzing each individual pixel sequence of the image data. A detailed analysis of the performance characteristics of three different parameter estimation schemes was performed. The analysis included examination of errors caused by statistical uncertainties in the measured data, errors in the timing of the data, and errors caused by violation of various assumptions of the tracer kinetic model. Two specific radioindicators were investigated. ('18)F -fluoromethane, an inert freely diffusible gas, was used for local quantitative determinations of both cerebral blood flow and tissue:blood partition coefficient. A method was developed that did not require direct sampling of arterial blood for the absolute scaling of flow values. The arterial input concentration time course was obtained by assuming that the alveolar or end-tidal expired breath radioactivity concentration is proportional to the arterial blood concentration. The scale of the input function was obtained from a series of venous blood concentration measurements. The method of absolute scaling using venous samples was validated in four studies, performed on normal volunteers, in which directly measured arterial concentrations were compared to those predicted from the expired air and venous blood samples. The glucose analog ('18)F-3-deoxy-3-fluoro-D -glucose (3-FDG) was used for quantitating the membrane transport rate of glucose. The measured data indicated that the phosphorylation rate of 3-FDG was low enough to allow accurate estimation of the transport rate using a two compartment model.

  10. (R)-[¹¹C]Emopamil as a novel tracer for imaging enhanced P-glycoprotein function.

    PubMed

    Toyohara, Jun; Okamoto, Mayumi; Aramaki, Hiroki; Zaitsu, Yuto; Shimizu, Isao; Ishiwata, Kiichi

    2016-01-01

    2-Isopropyl-5-[methyl-(2-phenylethyl)amino]-2-phenylpentanenitrile (emopamil; EMP) is a calcium channel blocker of the phenylalkylamine class, with weak substrate properties for P-glycoprotein (P-gp). A weak substrate for P-gp would be suitable for measuring enhanced P-gp function. This study was performed to synthesise (R)- and (S)-[(11)C]EMP and characterise their properties as P-gp tracers. We synthesised (R)- and (S)-[(11)C]EMP and compared their biodistribution, peripheral metabolism, and effects of the P-gp inhibitor cyclosporine A (CsA, 50 mg/kg). We compared the brain pharmacokinetics of (R)-[(11)C]EMP and (R)-[(11)C]verapamil [(R)-[(11)C]VER] at baseline and CsA pretreatment with small animal positron emission tomography (PET). (R)- and (S)-[(11)C]EMP were synthesised from (R)- and (S)-noremopamil, respectively, by methylation with [(11)C]methyl triflate in the presence of NaOH at room temperature. (R)- and (S)-[(11)C]EMP yields were ~30%, with specific activity>74 GBq/μmol and radiochemical purity>99%. (R)-[(11)C]EMP showed significantly greater uptake in the mouse brain than (S)-[(11)C]EMP. Both showed homogeneous non-stereoselective regional brain distributions. (R)- and (S)-[(11)C]EMP were rapidly metabolised to hydrophilic metabolites. Unchanged plasma (S)-[(11)C]EMP level was significantly lower than that of (R)-[(11)C]EMP 15 minutes post-injection, whilst>88% of radioactivity in the brain was intact at 15 minutes post-injection and was non-stereoselective. CsA pretreatment increased brain activity ~3-fold in mice, but was non-stereoselective. The baseline area-under-the-curve (AUC) of brain radioactivity (0-60 minutes) of (R)-[(11)C]EMP was 2-fold higher than that of (R)-[(11)C]VER, but their AUCs after CsA pretreatment were comparable. (R)-[(11)C]EMP is a novel tracer for imaging P-gp function with higher baseline uptake than (R)-[(11)C]VER. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. A model to measure lymphatic drainage from the eye.

    PubMed

    Kim, Minhui; Johnston, Miles G; Gupta, Neeru; Moore, Sara; Yücel, Yeni H

    2011-11-01

    Intraocular pressure (IOP) is the most important risk factor for glaucoma development and progression. Most anti-glaucoma treatments aim to lower IOP by enhancing aqueous humor drainage from the eye. Aqueous humor drainage occurs via well-characterized trabecular meshwork (TM) and uveoscleral (UVS) pathways, and recently described ciliary body lymphatics. The relative contribution of the lymphatic pathway to aqueous drainage is not known. We developed a sheep model to quantitatively assess lymphatic drainage along with TM and UVS outflows. This study describes that model and presents our initial findings. Following intracameral injection of (125)I-bovine serum albumin (BSA), lymph was continuously collected via cannulated cervical lymphatic vessels and the thoracic lymphatic duct over either a 3-h or 5-h time period. In the same animals, blood samples were collected from the right jugular vein every 15 min. Lymphatic and TM drainage were quantitatively assessed by measuring (125)I-BSA in lymph and plasma, respectively. Radioactive tracer levels were also measured in UVS and "other" ocular tissue, as well as periocular tissue harvested 3 and 5 h post-injection. Tracer recovered from UVS tissue was used to estimate UVS drainage. The amount of (125)I-BSA recovered from different fluid and tissue compartments was expressed as a percentage of total recovered tracer. Three hours after tracer injection, percentage of tracer recovered in lymph and plasma was 1.64% ± 0.89% and 68.86% ± 9.27%, respectively (n = 8). The percentage of tracer in UVS, other ocular and periocular tissues was 19.87% ± 5.59%, 4.30% ± 3.31% and 5.32% ± 2.46%, respectively. At 5 h (n = 2), lymphatic drainage was increased (6.40% and 4.96% vs. 1.64%). On the other hand, the percentage of tracer recovered from UVS and other ocular tissue had decreased, and the percentage from periocular tissue showed no change. Lymphatic drainage increased steadily over the 3 h post-injection period, while TM drainage increased rapidly - reaching a plateau at 30 min. This quantitative sheep model enables assessment of relative contributions of lymphatic drainage, TM and UVS outflows, and may help to better understand the effects of glaucoma agents on outflow pathways. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Biodistribution and radiation dosimetry in healthy volunteers of a novel tumour-specific probe for PET/CT imaging: BAY 85-8050.

    PubMed

    Smolarz, Kamilla; Krause, Bernd Joachim; Graner, Frank Philipp; Wagner, Franziska Martina; Wester, Hans-Jürgen; Sell, Tina; Bacher-Stier, Claudia; Fels, Lüder; Dinkelborg, Ludger; Schwaiger, Markus

    2013-12-01

    Novel tracers for the diagnosis of malignant disease with PET and PET/CT are being developed as the most commonly used (18)F deoxyglucose (FDG) tracer shows certain limitations. Employing radioactively labelled glutamate derivatives for specific imaging of the truncated citrate cycle potentially allows more specific tumour imaging. Radiation dosimetry of the novel tracer BAY 85-8050, a glutamate derivative, was calculated and the effective dose (ED) was compared with that of FDG. Five healthy volunteers were included in the study. Attenuation-corrected whole-body PET/CT scans were performed from 0 to 90 min, at 120 and at 240 min after injection of 305.0 ± 17.6 MBq of BAY 85-8050. Organs with moderate to high uptake at any of the imaging time points were used as source organs. Total activity in each organ at each time point was measured. Time-activity curves (TAC) were determined for the whole body and all source organs. The resulting TACs were fitted to exponential equations and accumulated activities were determined. OLINDA/EXM software was used to calculate individual organ doses and the whole-body ED from the acquired data. Uptake of the tracer was highest in the kidneys due to renal excretion of the tracer, followed by the pancreas, heart wall and osteogenic cells. The mean organ doses were: kidneys 38.4 ± 11.2 μSv/MBq, pancreas 23.2 ± 3.8 μSv/MBq, heart wall 17.4 ± 4.1 μSv/MBq, and osteogenic cells 13.6 ± 3.5 μSv/MBq. The calculated ED was 8.9 ± 1.5 μSv/MBq. Based on the distribution and dose estimates, the calculated radiation dose of BAY 85-8050 is 2.67 ± 0.45 mSv at a patient dose of 300 MBq, which compares favourably with the radiation dose of FDG (5.7 mSv).

  13. Comparing 2-[18F]fluoro-2-deoxy-D-glucose and [68Ga]gallium-citrate translocation in Arabidopsis thaliana.

    PubMed

    Fatangare, Amol; Gebhardt, Peter; Saluz, Hanspeter; Svatoš, Aleš

    2014-10-01

    2-[(18)F]fluoro-2-deoxy-D-glucose ((18)FDG) is a glucose surrogate commonly used in clinical or animal imaging but rarely in plant imaging to trace glucose metabolism. Recently, (18)FDG has been employed in plant imaging for studying photoassimilate translocation and glycoside biosynthesis. There is growing evidence that (18)FDG could be used as a tracer in plant imaging studies to trace sugar dynamics. However, to confirm this hypothesis, it was necessary to show that the observed (18)FDG distribution in an intact plant is an outcome of the chemical nature of the introduced radiotracer and not of the plant vascular architecture or radiotracer introduction method. In the present work, we fed (18)FDG and [(68)Ga]gallium-citrate ((68)Ga-citrate) solution through mature Arabidopsis thaliana leaf and monitored subsequent radioactivity distribution using positron autoradiography. The possible route of radioactivity translocation was elucidated through stem-girdling experiments. We also employed a bi-functional positron emission tomography/computed tomography (PET/CT) modality to capture (18)FDG radiotracer dynamics in one of the plants in order to assess applicability of PET/CT for 4-D imaging in an intact plant. Autoradiography results showed that [(18)F] radioactivity accumulated mostly in roots and young growing parts such as the shoot apex, which are known to act as sinks for photoassimilate. [(18)F] radioactivity translocation, in this case, occurred mainly via phloem. PET/CT results corroborated with autoradiography. [(68)Ga] radioactivity, on the other hand, was mainly translocated to neighboring leaves and its translocation occurred via both xylem and phloem. The radioactivity distribution pattern and translocation route observed after (18)FDG feeding is markedly different from that of (68)Ga-citrate. [(18)F] radioactivity distribution pattern in an intact plant is found similar to the typical distribution pattern of photoassimilates. Despite its limitations in quantification and resolution, PET/CT could be a useful tool to elucidate in vivo dynamics of [(18)F] radioactivity in intact plants. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. [Evaluation of therapies in oncology by positron emission tomography: towards therapeutical personalization].

    PubMed

    Bonardel, G; Vedrine, L; Aupee, O; Gontier, E; Le Garlantezec, P; Soret, M; Foehrenbach, H

    2009-02-01

    Recently introduced into clinical practice, positron emission tomography (PET) with 18F-fluorodeoxyglucose (FDG) has proven its utility for diagnosis and staging of malignant diseases on account of its ability for tissue identification. Its utilization is now moving toward the evaluation of anti-tumoral effects of anticancer therapy, because of the correlation between the uptake of a metabolic tracer and malignant cells viability. Metabolic effects of chemotherapy are first observed in cells and this is the explanation for the precocity of scintigraphic visualisation of therapeutic activity. However, monitoring response with FDG-PET requires rigorous method and needs to take into account the limitations of SUV. Moreover, in order to go beyond the limitations of FDG, new tracers are developed and their main indication could be precisely the monitoring of therapy response. The properties of positron emitters allow us to foresee the labelling of the therapeutic molecules themselves in order to try them in vivo before their utilization for a given patient. These prospects are the ground for real treatment personalization in oncology. They open up a wide field of clinical research but the means for image acquisition and radioactive tracers production will be mandatory for anyone who wants to contribute to this work. Due to the current performances of the imaging systems, the critical point will be availability of equipment allowing the designing and synthesis of the radiopharmaceuticals of the future.

  15. Computer registration of radioactive indicator-dilution curves.

    PubMed

    Shepherd, A P; Perry, M A; Alexander, G M; Granger, D N; Riedel, G L; Kvietys, P R; Franke, C P

    1983-12-01

    A system is described for recording indicator-dilution curves produced by gamma radiation-emitting tracers. The system consists of a flow-through cuvette in a well counter, appropriate commercially available gamma radiation-detecting equipment, an Apple II computer, and a two-channel pulse-counting interface of our own design. With the counting interface and the software described here, an investigator can simultaneously record two indicator-dilution curves produced by gamma emitters. Instead of having to wait hours or days for results, the investigator can watch the data being recorded and display the results in graphic form almost immediately after each injection.

  16. Post-Explosion Tracer Gas Study in Fractured Granite

    NASA Astrophysics Data System (ADS)

    Avendano, S.; Horne, M.; Herrera, C.; Person, M. A.; Gorman, E.; Stroujkova, A. F.; Gomez-Velez, J. D.

    2017-12-01

    Radioactive noble gas detection at suspected underground nuclear test sites is the only proven way to confirm that a nuclear test has occurred. However, the migration of gas effluent through fracture networks is still poorly understood. A pilot field study of the gas migration through rock damaged by explosions was conducted in a rock quarry in New Hampshire in the summer of 2017. Tracer gas (SF6), used as a proxy for the noble gas, was released into a cavity created by an explosion (63 kg of TNT at a depth of 13 m) conducted during the summer of 2016. The upper 5 m of borehole were grouted with stainless steel tubing sealed in the concrete and the gas was pumped through the tubing. Before the gas release, we conducted a series of geophysical and hydrologic tests: a pump test, several slug tests, a salt tracer release in two boreholes, and TEM and ERT surveys. Pressure and electrical conductivity transducers were placed in the surrounding boreholes to monitor the pressure changes and tracer arrival during the pumping. The results of the pump test show that the rock is well connected and has high permeability. Interestingly, the injection of gas resulted in a substantial increase of the local hydraulic conductivity, as evidenced by slug test results before and after injection. The pressure changes in the surrounding boreholes were also monitored during the gas release. We observed gas breakthrough immediately after the release. During the first minute after injection, a pressure wave was observed in two boreholes suggestive of inertial effects and hydraulic fracturing after gas release. The concentrations observed at each monitoring site are consistent with the pump testing. The results of this study will be used in our upcoming experiments and to test detailed mathematical models.

  17. Phosphorous retention in a remediated stream - evaluation of a 32P tracer experiment

    NASA Astrophysics Data System (ADS)

    Riml, Joakim; Morén, Ida; Wörman, Anders

    2017-04-01

    The increased attention to surface water quality problems together with the revealed importance of the stream water -hyporheic zone system for solute retention has highlighted the potential for surface water systems to mitigate solute export to downstream recipients. As a consequence, the number of stream restoration projects during the last decades has increased significantly. However, to be able to design remediation measures as well as to assess the effectiveness of implemented measures, quantitative knowledge of the hydrodynamic (substance independent) and the biogeochemical processes (substance dependent) retaining the solute along the transport pathway is needed. In this work, we present the findings from a simultaneous injection of tritiated water (3H20) and phosphate (32PO4-) with the overall aim to evaluate the effectiveness of remediation actions implemented along a 6 km stretch of a small agricultural stream in Sweden. In contrast to many other tracer tests where different types of proxy substances are used, a key advantage of the study is the use of the substance of environmental interest (in this case phosphorous), which enhances the significance of the results. In addition, the unique radioactive signal from the injected tracer allowed us to distinguish the added phosphorous from other diffuse sources of phosphorous from the surrounding landscape. By using a physically based transport model to evaluate the tracer breakthrough curves at a number of subsequent sampling stations, we were able to contrast the response of different stream reaches both with respect to hydrodynamic and biogeochemical retention. In particular, we found a substantial importance of vegetation on the retention of 32P, when comparing established reaches with dense in-stream vegetation with newly implemented reaches where vegetation was completely absent.

  18. A new statistical dispersion model for tracer tests and contaminant spread in porous media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ates, H.; Kasap, E.

    Dispersion of solutes moving in permeable media is an essential control to describe fluid flow in permeable media. Dispersion can be thought of as a spreading of a solute caused by the presence of microscopic inhomogeneities. An accurate model for dispersion is needed for accurate estimation of oil recovery efficiencies and clean up costs of subsurface contaminants. Current approaches utilizing the fickian assumption fall short in describing the real physics of spreading during a solute transport process. Numerous field investigations have shown that dispersivities measured in the field are much larger than those measured in the lab for the samemore » type of porous material. Moreover, field measured dispersivities have been shown to be scale dependent, that is, a tracer test conducted over a longer travel path will yield a larger dispersivity value than a tracer test conducted in the same geologic formation over a shorter travel path. Numerous approaches to address this problem have been developed yet none attempted to go beyond the Fickian dispersion assumption. In this study, a convective dispersivity is introduced. New model assumes that dispersion is dimensionless and mainly determined by pore size distribution. The new model results in a spread that increases linearly with time contrary to conventional model, which predicts a mixing zone length that increases with square root of time. Therefore, new model explains the field test results that indicate increasing dispersivity with distance. The model validations are in perfect agreement with experimental results, which include; Ganapathy et al.`s slug experiment on Antolini sandstone, Handy`s radioactive tracer experiment on Alhambra sandstone, and CT experiment conducted at BDM-OK/NIPER facilities on Tallant sandstone.« less

  19. Binding and degradation of 125I-gastrin by plasma membranes from homogenized rat gastric mucosa.

    PubMed

    Kleveland, P M; Waldum, H L

    1986-06-01

    Binding of 125I-gastrin to the 270-30,000 g fraction from homogenized rat oxyntic mucosa was studied. 'Specific' binding was calculated by subtracting the binding at excess cold gastrin from the binding with labelled gastrin (250 pM) only. At 30 degrees C specific binding rose rapidly to a short-lived maximum before falling gradually, whereas at 15 degrees C and 0 degree C specific binding rose gradually to a higher plateau level. The reduced binding at 30 degrees C could be caused by degradation of either the tracer or the binding site or by a combination of these two events. Degradation of 125I-gastrin was evaluated by trichloroacetic acid (TCA) precipitation, fast protein liquid chromatography, and binding to a gastrin antibody (immunoreactivity). The effect of incubation on the binding site was evaluated by preincubation of the homogenate fraction before adding gastrin. In separate studies, the proteolytic activity of the homogenate fraction was studied by TCA precipitation of radioactive casein. Different enzyme inhibitors tested were virtually ineffective in preventing gastrin and casein degradation. Only lowering the incubation temperature to 15 degrees C or lower could prevent this degradation. The reduced and transient binding of 125I-gastrin at 30 degrees C most probably reflects tracer degradation. Accordingly, the gastrin binding experiments were performed at 15 degrees C. Only homogenates from the oxyntic area of the stomach bound 125I-gastrin specifically and with a Kd of 0.8 nM (Scatchard analysis). However, micromolar concentrations of unlabelled gastrin were required to inhibit half maximal binding of the tracer. The tracer binding was unaffected by secretin, slightly reduced by a CCK-9 analogue, and more markedly reduced by pentagastrin.

  20. 129I in the oceans: origins and applications.

    PubMed

    Raisbeck, G M; Yiou, F

    1999-09-30

    The quantity of the long lived (half-life 15.7 million years) radioactive isotope 129I in the pre-nuclear age ocean was approximately 100 kg. Various nuclear related activities, including weapons testing, nuclear fuel reprocessing, Chernobyl and other authorized or non-authorized dumping of radioactive waste have increased the ocean inventory of 129I by more than one order of magnitude. The most important of these sources are the direct marine discharges from the commercial reprocessing facilities at La Hague (France) and Sellafield (UK) which have discharged approximately 1640 kg in the English Channel, and approximately 720 kg in the Irish Sea, respectively. We discuss how this 129I can be used as both a 'pathway' and 'transit time' tracer in the North Atlantic and Arctic oceans, as well as a parameter for distinguishing between reprocessed and non-reprocessed nuclear waste in the ocean, and as a proxy for the transport and dilution of other soluble pollutants input to the North Sea.

  1. Marine Radioactivity Studies in the Suez Canal, Part II: Field Experiments and a Modelling Study of Dispersion

    NASA Astrophysics Data System (ADS)

    Abril, J. M.; Abdel-Aal, M. M.; Al-Gamal, S. A.; Abdel-Hay, F. A.; Zahar, H. M.

    2000-04-01

    In this paper we take advantage of the two field tracing experiments carried out under the IAEA project EGY/07/002, to develop a modelling study on the dispersion of radioactive pollution in the Suez Canal. The experiments were accomplished by using rhodamine B as a tracer, and water samples were measured by luminescence spectrometry. The presence of natural luminescent particles in the canal waters limited the use of some field data. During experiments, water levels, velocities, wind and other physical parameters were recorded to supply appropriate information for the modelling work. From this data set, the hydrodynamics of the studied area has been reasonably described. We apply a 1-D-Gaussian and 2-D modelling approaches to predict the position and the spatial shape of the plume. The use of different formulations for dispersion coefficients is studied. These dispersion coefficients are then applied in a 2-D-hydrodynamic and dispersion model for the Bitter Lake to investigate different scenarios of accidental discharges.

  2. Historical perspective on lead biokinetic models.

    PubMed Central

    Rabinowitz, M

    1998-01-01

    A historical review of the development of biokinetic model of lead is presented. Biokinetics is interpreted narrowly to mean only physiologic processes happening within the body. Proceeding chronologically, for each epoch, the measurements of lead in the body are presented along with mathematical models in an attempt to trace the convergence of observations from two disparate fields--occupational medicine and radiologic health--into some unified models. Kehoe's early balance studies and the use of radioactive lead tracers are presented. The 1960s saw the joint application of radioactive lead techniques and simple compartmental kinetic models used to establish the exchange rates and residence times of lead in body pools. The applications of stable isotopes to questions of the magnitudes of respired and ingested inputs required the development of a simple three-pool model. During the 1980s more elaborate models were developed. One of their key goals was the establishment of the dose-response relationship between exposure to lead and biologic precursors of adverse health effects. PMID:9860905

  3. Shuttle filter study. Volume 2: Contaminant generation and sensitivity studies

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Contaminant generation studies were conducted at the component level using two different methods, radioactive tracer technique and gravimetric analysis test procedure. Both of these were reduced to practice during this program. In the first of these methods, radioactively tagged components typical of those used in spacecraft were studied to determine their contaminant generation characteristics under simulated operating conditions. Because the purpose of the work was: (1) to determine the types and quantities of contaminants generated; and (2) to evaluate improved monitoring and detection schemes, no attempt was made to evaluate or qualify specific components. The components used in this test program were therefore not flight hardware items. Some of them had been used in previous tests; some were obsolete; one was an experimental device. In addition to the component tests, various materials of interest to contaminant and filtration studies were irradiated and evaluated for use as autotracer materials. These included test dusts, plastics, valve seat materials, and bearing cage materials.

  4. The Path of Carbon in Photosynthesis XX. The Steady State

    DOE R&D Accomplishments Database

    Calvin, M.; Massini, Peter

    1952-09-01

    The separation of the phenomenon of photosynthesis in green plants into a photochemical reaction and into the light-dependent reduction of carbon dioxide is discussed, The reduction of carbon dioxide and the fate of the assimilated carbon were investigated with the help of the tracer technique (exposure of the planks to the radioactive C{sup 14}O{sub 2}) and of paper chromatography. A reaction cycle is proposed in which phosphoglyceric acid is the first isolable assimilations product. Analyses of the algal extracts which had assimilated radioactive carbon dioxide in a stationary condition ('steady-state' photosynthesis) for a long time provided further information concerning the proposed cycle and permitted the approximate estimation, for a number of compounds of what fraction of each compound was taking part in the cycle. The earlier supposition that light influences the respiration cycle was confirmed. The possibility of the assistance of {alpha}-lipoic acid, or of a related substance, in this influence and in the photosynthesis cycle, is discussed.

  5. [From Chernobyl to Morsleben--a public health observation].

    PubMed

    Thriene, B

    1999-11-01

    On April 26, 1986, a serious reactor accident occurred at the Chernobyl nuclear power plant. A total radioactivity of 2 x 10(18) becquerel, i.e. 3.5% of the reactor inventory were released spreading throughout Europe. Radioactive tracers were iodine 131 (with a half-life of 8 days) and caesium 137 (with a half-life of 30 years). Measurements made in Magdeburg by the Institute of Hygiene on May 5th after a heavy thunderstorm indicated a considerable radioactive contamination. Measurements revealed 75,000 bq/kg in grasses, 44,000 bq/litre in storm water and 40,000 bq/kg in garden soil, however, these high values decreased to normal by the end of 1986. The paper describes a stay in Chernobyl in 1989 and the environmental and working conditions prevailing at site. An increase of the cancer rate in the contaminated areas was not observed until 1990; however, thyroid tumours increased in children in Belorussia after that time. The current caesium load of the soils in the area is 10(6) becquerel/cubic metre. As much as 480,000 bq/kg were measured in dried mushrooms picked in the autumn of 1997. Assuming a mean natural exposure to radiation of the population in Germany of 2.4 millisievert/year (mSv/a), the additional load caused by the Chernobyl accident was 5% in 1986, falling to below 0.1% in 1996. Today, 19 nuclear power plants are operating in Germany for power generation. Radioactive substances are used in medicine, research and industry. An opinion on the safety of transports and final dumping of radioactive waste is given, based on a visit to the Morsleben final dump site. The use of nuclear energy and a percentage replacement by renewable energies are discussed from a regional and global perspective (climate protection).

  6. Salt tracer experiments in wetland ponds: will density stratification spoil the outcome?

    NASA Astrophysics Data System (ADS)

    Schmid, Bernhard H.; Hengl, Michael A.

    2017-04-01

    Wetland ponds are among the treatment options for peatland flows prior to their discharge into a receiving ambient water course or water body. The removal efficiency and effectiveness of wetland ponds (free water surface or FWS wetlands) is considered to be strongly related to the residence time or travel time distribution in the pond, with a narrow distribution (close to plug flow) being preferable to a wider one. This travel time distribution is, in turn, reflected by a breakthrough curve of an ideal tracer injected instantaneously into the flow (entering the wetland). As the term 'ideal tracer' suggests, such a substance, in real world cases, does not exist and can, at best, be approximated by a real tracer. Among the tracer groups in most widespread use, salt has the advantage of low cost, straightforward detection and analysis as well as low related environmental risk. In contrast, use of radioactive artificial tracers may meet with resistance from authorities and public, and fluorescent dyes are not necessarily devoid of problems, either (as recently discovered, there are two structural isomers of Rhodamin WT, the mixture of which may compromise the validity of breakthrough data analyses). From previous work by the authors it is known that density stratification may result from the injection of a salt tracer into a low Reynolds number free surface flow, which is a frequent characteristic of wetland ponds. As the formation of density layers in the course of a tracer experiment is highly undesirable, it may be useful to judge prior to beginning of the field work, if stratification is to be expected (and the experimental design should, consequently, be adapted suitably). The current work reported here employs an energy argument to extend existing criteria for density stratification in turbulent free surface flows. Vertical mixing is assumed to be sustained by a fraction of the frictional energy loss (expressed by Manning's law, but this can easily be adapted to other friction laws such as Darcy-Weisbach's). Experimental data obtained by the authors in the course of the PRIMROSE project (Contract no. EVK1-CT-2000-00065) were used to calibrate the criterion with respect to the actual percentage of the friction loss that fuels the vertical mixing. The distance x (m) needed for (full) vertical mixing of the salt tracer (NaCl or KBr) is finally derived as: C0 ṡ(0.802- 0.002ṡTw) ṡh R4h/3 x =----0.0694-ṡρw----ṡ(n-ṡu)2 (1) with C = -M0-- 0 Q ṡΔt0 (2) and M0 the tracer mass (g), Q the flow rate (m3/s), Δt0 the injection pulse duration (s), Rh (m) the hydraulic radius (= flow cross-sectional area divided by wetted perimeter), Tw the water temperature (˚ C), ρw water mass density (g/m3), Manning's n in SI-units (s/m1/3) and cross-sectionally averaged flow velocity u (m/s). Tracer concentration C0, as obtained from Eq.(2), is to be expressed in mg/l or g/m3 for use in Eq.(1).

  7. Investigation of Deep Ocean Circulation and Mixing Using Ar-39 (Invited)

    NASA Astrophysics Data System (ADS)

    Smethie, W. M.; Schlosser, P.

    2013-12-01

    Ar-39 is a radioactive noble gas that forms in the atmosphere by cosmic ray interaction with Ar-40. It has a half-life of 269 years and its production rate in the atmosphere has varied no more than 7% during the past 1000 years. It enters the surface ocean with an average equilibration time of about one month and thus the entire surface ocean, except for ice covered regions at high latitudes, is in quasi-equilibrium with the atmospheric Ar-39:Ar ratio. The well known input to the ocean, radioactive decay constant and chemical inertness make Ar-39 an ideal tracer of circulation and mixing in the deep ocean, where anthropogenic transient tracers such as CFCs and tritium have not yet penetrated. However, due to the difficult measurement, only about 125 oceanic Ar-39 samples have been measured to date. This was done by counting the decays of Ar-39 atoms and required a half liter of argon gas per sample, extracted from about 1500 liters of water. The 125 samples that have been measured provide a glimpse of the information that can be gained from Ar-39 observations. In the Pacific Ocean three vertical profiles show a decrease in Ar-39 from the surface mixed layer through the thermocline to a minimum at intermediate depths and an increase from there to the bottom. This reflects formation of bottom water around the Antarctic continent, spreading of this water northward and upwelling and mixing into intermediate depths. The lowest concentration was 6×4% modern which is equivalent to a 900-1600 year isolation time from the surface. In the Atlantic Ocean newly formed North Atlantic Deep Water has an Ar-39 concentration of about 85% modern compared to 55% modern for newly formed Antarctic Bottom Water and reach values as low as about 40% modern in the interior reflecting the more rapid ventilation of the deep Atlantic Ocean relative to the deep Pacific Ocean. In the Arctic Ocean the mean residence time of deep water in the Nansen, Amundsen and Makarov Basins based on Ar-39 are about 270, 190, and 330 years respectively. Radiocarbon also provides information on circulation and mixing in the deep ocean and thousands of measurements have been made. However, the distributions of Ar-39 and C-14 are different due to the large difference in their half-lives (269 years and 5730 years respectively). Measurement of both tracers provides information on the relative importance of advection and mixing in the deep ocean and provides more accurate transit times than can be obtained with only one of these tracers. In the Atlantic Ocean, where the deep water is roughly a two-end member mixture of northern component and southern component water, the age of the two components can be estimated from simultaneous measurement of Ar-39 and C-14. The few existing measurements suggest that the northern component water has an age range of 40-200 years and the southern component water a range of 60-600 years. Development of the ATTA method for measuring radioactive noble gases offers great potential to dramatically increase the number of samples that can be measured for Ar-39, which could greatly improve our understanding of mixing and circulation in the deep ocean.

  8. The false-negative rate of sentinel node biopsy in patients with breast cancer: a meta-analysis

    PubMed Central

    Pesek, Sarah; Ashikaga, Taka; Krag, Lars Erik; Krag, David

    2012-01-01

    Background/Purpose In sentinel node surgery for breast cancer, procedural accuracy is assessed by calculating the false-negative rate. It is important to measure this since there are potential adverse outcomes from missing node metastases. We performed a meta-analysis of published data to assess which method has achieved the lowest false-negative rate. Methods We found 3588 articles concerning sentinel nodes and breast cancer published from 1993 through mid-2011; 183 articles met our inclusion criteria. The studies described in these 183 articles included a total of 9306 patients. We grouped the studies by injection material and injection location. The false-negative rates were analyzed according to these groupings and also by the year in which the articles were published. Results There was significant variation in the false-negative rate over time with a trend to higher rates over time. There was significant variation related to injection material. The use of blue dye alone was associated with the highest false-negative rate. Inclusion of a radioactive tracer along with blue dye resulted in a significantly lower false-negative rate. Although there were variations in the false-negative rate according to injection location, none were significant. This meta-analysis also indicates a significant change over time in the false-negative rate. Discussion/Conclusions The use of blue dye should be accompanied by a radioactive tracer to achieve a significantly lower false-negative rate. Location of injection did not have a significant impact on the false-negative rate. Given the limitations of acquiring appropriate data, the false-negative rate should not be used as a metric for training or quality control. PMID:22569745

  9. Binding of ReO[subscript 4];#8722; with an engineered MoO[subscript 4 superscript 2];#8722;-binding protein: towards a new approach in radiopharmaceutical applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aryal, Baikuntha P.; Brugarolas, Pedro; He, Chuan

    2012-05-25

    Radiolabeled biomolecules are routinely used for clinical diagnostics. {sup 99m}Tc is the most commonly used radioactive tracer in radiopharmaceuticals. {sup 188}Re and {sup 186}Re are also commonly used as radioactive tracers in medicine. However, currently available methods for radiolabeling are lengthy and involve several steps in bioconjugation processes. In this work we present a strategy to engineer proteins that may selectively recognize the perrhenate (ReO{sub 4}{sup -}) ion as a new way to label proteins. We found that a molybdate (MoO{sub 4}{sup 2-})-binding protein (ModA) from Escherichia coli can bind perrhenate with high affinity. Using fluorescence and isothermal titration calorimetrymore » measurements, we determined the dissociation constant of ModA for ReO{sub 4}{sup -} to be 541 nM and we solved a crystal structure of ModA with a bound ReO{sub 4}{sup -}. On the basis of the structure we created a mutant protein containing a disulfide linkage, which exhibited increased affinity for perrhenate (K{sub d} = 104 nM). High-resolution crystal structures of ModA (1.7 {angstrom}) and A11C/R153C mutant (2.0 {angstrom}) were solved with bound perrhenate. Both structures show that a perrhenate ion occupies the molybdate binding site using the same amino acid residues that are involved in molybdate binding. The overall structure of the perrhenate-bound ModA is unchanged compared with that of the molybdate-bound form. In the mutant protein, the bound perrhenate is further stabilized by the engineered disulfide bond.« less

  10. Spectral K-edge subtraction imaging of experimental non-radioactive barium uptake in bone.

    PubMed

    Panahifar, Arash; Samadi, Nazanin; Swanston, Treena M; Chapman, L Dean; Cooper, David M L

    2016-12-01

    To evaluate the feasibility of using non-radioactive barium as a bone tracer for detection with synchrotron spectral K-edge subtraction (SKES) technique. Male rats of 1-month old (i.e., developing skeleton) and 8-month old (i.e., skeletally mature) were orally dosed with low dose of barium chloride (33mg/kg/day Ba 2+ ) for 4weeks. The fore and hind limbs were dissected for imaging in projection and computed tomography modes at 100μm and 52μm pixel sizes. The SKES method utilizes a single bent Laue monochromator to prepare a 550eV energy spectrum to encompass the K-edge of barium (37.441keV), for collecting both 'above' and 'below' the K-edge data sets in a single scan. The SKES has a very good focal size, thus limits the 'crossover' and motion artifacts. In juvenile rats, barium was mostly incorporated in the areas of high bone turnover such as at the growth plate and the trabecular surfaces, but also in the cortical bone as the animals were growing at the time of tracer administration. However, the adults incorporated approximately half the concentration and mainly in the areas where bone remodeling was predominant and occasionally in the periosteal and endosteal layers of the diaphyseal cortical bone. The presented methodology is simple to implement and provides both structural and functional information, after labeling with barium, on bone micro-architecture and thus has great potential for in vivo imaging of pre-clinical animal models of musculoskeletal diseases to better understand their mechanisms and to evaluate the efficacy of pharmaceuticals. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. Solar r-process-constrained actinide production in neutrino-driven winds of supernovae

    NASA Astrophysics Data System (ADS)

    Goriely, S.; Janka, H.-Th.

    2016-07-01

    Long-lived radioactive nuclei play an important role as nucleo-cosmochronometers and as cosmic tracers of nucleosynthetic source activity. In particular, nuclei in the actinide region like thorium, uranium, and plutonium can testify to the enrichment of an environment by the still enigmatic astrophysical sources that are responsible for the production of neutron-rich nuclei by the rapid neutron-capture process (r-process). Supernovae and merging neutron-star (NS) or NS-black hole binaries are considered as most likely sources of the r-nuclei. But arguments in favour of one or the other or both are indirect and make use of assumptions; they are based on theoretical models with remaining simplifications and shortcomings. An unambiguous observational determination of a production event is still missing. In order to facilitate searches in this direction, e.g. by looking for radioactive tracers in stellar envelopes, the interstellar medium or terrestrial reservoirs, we provide improved theoretical estimates and corresponding uncertainty ranges for the actinide production (232Th, 235, 236, 238U, 237Np, 244Pu, and 247Cm) in neutrino-driven winds of core-collapse supernovae. Since state-of-the-art supernova models do not yield r-process viable conditions - but still lack, for example, the effects of strong magnetic fields - we base our investigation on a simple analytical, Newtonian, adiabatic and steady-state wind model and consider the superposition of a large number of contributing components, whose nucleosynthesis-relevant parameters (mass weight, entropy, expansion time-scale, and neutron excess) are constrained by the assumption that the integrated wind nucleosynthesis closely reproduces the Solar system distribution of r-process elements. We also test the influence of uncertain nuclear physics.

  12. Concurrent determination of 237Np and Pu isotopes using ICP-MS: analysis of NIST environmental matrix standard reference materials 4357, 1646a, and 2702.

    PubMed

    Matteson, Brent S; Hanson, Susan K; Miller, Jeffrey L; Oldham, Warren J

    2015-04-01

    An optimized method was developed to analyze environmental soil and sediment samples for (237)Np, (239)Pu, and (240)Pu by ICP-MS using a (242)Pu isotope dilution standard. The high yield, short time frame required for analysis, and the commercial availability of the (242)Pu tracer are significant advantages of the method. Control experiments designed to assess method uncertainty, including variation in inter-element fractionation that occurs during the purification protocol, suggest that the overall precision for measurements of (237)Np is typically on the order of ± 5%. Measurements of the (237)Np concentration in a Peruvian Soil blank (NIST SRM 4355) spiked with a known concentration of (237)Np tracer confirmed the accuracy of the method, agreeing well with the expected value. The method has been used to determine neptunium and plutonium concentrations in several environmental matrix standard reference materials available from NIST: SRM 4357 (Radioactivity Standard), SRM 1646a (Estuarine Sediment) and SRM 2702 (Inorganics in Marine Sediment). Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Towards real time spatially resolved data on sediment transport: 1) tracing the motion of the fluorescent soil particles under rainfall

    NASA Astrophysics Data System (ADS)

    Quinton, John; Hardy, Rob; Pates, Jackie; James, Mike

    2017-04-01

    Understanding where sediment originates from and where it travels to, in what quantities and at which rate is at the heart of many questions surrounding sediment transport, including the connectivity problem. Progress towards unravelling these questions and deepening our understanding has come from a wide range of approaches, including laboratory and field experiments conducted at a variety of scales. In seeking to understand the connectivity of sources and sinks of sediment scientists have spent considerable energy in developing tracing technologies. These have included numerous studies that have relied on the chemical properties of the soil and sediment to establish source-sink connectivity, and the use of 137Ceasium, from radioactive fall-out, to map sediment redistribution. More recently there has been an upsurge in interest in the use of artificially applied soil tracers, including rare earth element oxides and magnetic minerals. However all these tracing methods have a significant drawback: they rely on the collection of samples to assess their concentration. This means that their spatial distribution cannot easily be established in situ and that the environment that is being studied is damaged by the sampling process; nor can data be collected in real time which allows a dynamic understanding of erosion and transport processes to be developed. In this paper we present a methodology for use with a commercially available fluorescent tracer. The tracer is produced in a range of sizes and fluorescent signatures and can be applied to the soil surface. Here we report on an application that combines novel fluorescent videography techniques with custom image processing to trace the motion of the fluorescent soil particles under rainfall. Here we demonstrate the tracking of multiple sub-millimetre particles simultaneously, establishing their position 50 times a second with submillimetre precision. From this we are able to visualise and quantify parameters such as distance and direction of travel. In a second abstract we report on the field application of the tracer at the hillslope scale during a tillage erosion experiment. Here we trialled both intensity based and particle counting methodologies for tracer enumeration. After simulating seven years of tillage on a hillslope we were able to precisely determine the distribution of the fluorescent tracer and also its incorporation and distribution within the soil profile. Single grains of tracer could be found over 35 m from the insertion point.

  14. FNAS/LDEF Radiation Data Analysis

    NASA Technical Reports Server (NTRS)

    Gregory, John

    1998-01-01

    The radioactive isotope Be-7 was discovered on the forward-facing side of the LDEF satellite in amounts far exceeding that expected from direct cosmic ray activation of the spacecraft material. This prompted an examination of the production of cosmogenic isotopes in the atmosphere and of the processes by which they may be transported to orbital altitudes and absorbed by a spacecraft. Be-7 is only one of several atmospheric cosmogenic isotopes which might be detectable at orbital altitudes and which might prove to be as useful as tracers of atmospheric circulation processes in the mesosphere and thermosphere, as they have been in the lower layers of the atmosphere.

  15. Inferring Groundwater Age in an Alluvial Aquifer from Tracer Concentrations in the Stream - Little Wind River, Wyoming

    NASA Astrophysics Data System (ADS)

    Goble, D.; Gardner, W. P.; Naftz, D. L.; Solder, J. E.

    2017-12-01

    We use environmental tracers: CFC's, SF6, and 222Rn measured in stream water to determine volume and mean age of groundwater discharging to the Little Wind River, near Riverton, Wyoming. Samples of 222Rn were collected every 200 m along a 2 km reach, surrounding a known groundwater discharge zone. Nearby groundwater wells, in-stream piezometers and seepage meters were sampled for 222Rn, CFC's and SF6. Tracer concentrations measured in groundwater and in-stream piezometers were used to estimate the mean age of the subsurface system. High resolution 222Rn samples were used to determine the location and volume of groundwater inflow using a model of instream transport that includes radioactive decay and gas exchange with the atmosphere. The age of groundwater entering the stream was then estimated from in-stream measured CFC and SF6 concentrations using a new coupled stream transport and lumped-parameter groundwater age model. Ages derived from in-stream measurements were then compared to the age of subsurface water measured in piezometers, seepage meters, and groundwater wells. We then asses the ability of groundwater age inferred from in-stream samples to provide constraint on the age of the subsurface discharge to the stream. The ability to asses groundwater age from in-stream samples can provide a convenient method to constrain the regional distribution of groundwater circulation rates when groundwater sampling is challenging or wells are not in place.

  16. Evaluation of a 125I-labelled benzazepinone derived voltage-gated sodium channel blocker for imaging with SPECT.

    PubMed

    Pérez-Medina, Carlos; Patel, Niral; Robson, Mathew; Badar, Adam; Lythgoe, Mark F; Årstad, Erik

    2012-12-21

    Voltage-gated sodium channels (VGSCs) are a family of transmembrane proteins that mediate fast neurotransmission, and are integral to sustain physiological conditions and higher cognitive functions. Imaging of VGSCs in vivo holds promise as a tool to elucidate operational functions in the brain and to aid the treatment of a wide range of neurological diseases. To assess the suitability of 1-benzazepin-2-one derived VGSC blockers for imaging, we have prepared a (125)I-labelled analogue of BNZA and evaluated the tracer in vivo. In an automated patch-clamp assay, a diastereomeric mixture of the non-radioactive compound blocked the Na(v)1.2 and Na(v)1.7 VGSC isoforms with IC(50) values of 4.1 ± 1.5 μM and 0.25 ± 0.07 μM, respectively. [(3)H]BTX displacement studies revealed a three-fold difference in affinity between the two diastereomers. Iodo-destannylation of a tin precursor with iodine-125 afforded the two diastereomerically pure tracers, which were used to assess binding to VGSCs in vivo by comparing their tissue distributions in mice. Whilst the results point to a lack of VGSC binding in vivo, SPECT imaging revealed highly localized uptake in the interscapular region, an area typically associated with brown adipose tissue, which in addition to high metabolic stability of the iodinated tracer, demonstrate the potential of 1-benzazepin-2-ones for in vivo imaging.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glauber, H.; Wallace, P.; Brechtel, G.

    We studied the measurement of hepatic glucose output (HGO) with prolonged (3-/sup 3/H)glucose infusion in 14 patients with non-insulin-dependent diabetes mellitus (NIDDM). Over the course of 10.5 h, plasma glucose concentration fell with fasting by one-third, from 234 +/- 21 to 152 +/- 12 mg/dl, and HGO fell from 2.35 +/- 0.18 to 1.36 +/- 0.07 mg . kg-1 . min-1 (P less than .001). In the basal state, HGO and glucose were significantly correlated (r = 0.68, P = .03), and in individual patients, HGO and glucose were closely correlated as both fell with fasting (mean r = 0.79,more » P less than .01). Plasma (3-/sup 3/H)glucose radioactivity approached a steady state only 5-6 h after initiation of the primed continuous infusion, and a 20% overestimate of HGO was demonstrated by not allowing sufficient time for tracer labeling of the glucose pool. Assumption of steady-state instead of non-steady-state kinetics in using Steele's equations to calculate glucose turnover resulted in a 9-24% overestimate of HGO. Stimulation of glycogenolysis by glucagon injection demonstrated no incorporation of (3-/sup 3/H)glucose in hepatic glycogen during the prolonged tracer infusion. In a separate study, plasma glucose was maintained at fasting levels (207 +/- 17 mg/dl) for 8 h with the glucose-clamp technique. Total glucose turnover rates remained constant during this prolonged tracer infusion. However, HGO fell to 30% of the basal value simply by maintaining fasting hyperglycemia in the presence of basal insulin levels.« less

  18. RADIOLOGICAL PHYSICS DIVISION SEMIANNUAL REPORT FOR JULY THROUGH DECEMBER 1958

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1959-05-01

    ABS>Progress is reported in the following studies: the decay time of irradiated scintillation solutions; the performance of twin scintillation detectors for measuring neutrons in the presence of gamma radiation; the measurement of cosmic ray neutron background with a twin scintillation fast neutron spectrometer; the diffusion and absorption of gases in plastic-walled ionization chambers; calculations of the drift velocity and the energy distribution of electrons of helium, neon, argon, and nitrogen under the action of a uniform electric field; the development of equipment for tracer studies of atmospheric diffusion; the deposition and retention of isotopes of actinium, radon, radium, and thoriummore » in bone; the effects of age on calcium metabolism in bone,; the development of a mathematical theory of the retention of radioactive elements by bone; the development of a reproducible method for directly determining individual alpha activities in mixtures; the design of a flow-gas Geiger counter; a survey of the natural radioactivity of a number of municipal water supplies; measurements of activity in individuals by means of the human spectrometer; measurements of the cesium-l37 content of human subjects; measurements of the atmospheric content of cesium-137 as a function of time; a comparison of background radioactivity at the Laboratory and a site approximately 250 feet below grade level; development of a spectrometric method for measurements of radioactivity in soil; the effects of meteorological variables on the distribution of radon in the atmosphere; and studies of atmospheric diffusion. A list of publications during the period is included. (For preceding period see ANL-5919.) (C.H.)« less

  19. Spatially resolved data on sediment transport: 1) field application examining fluorescent soil particle movement from tillage

    NASA Astrophysics Data System (ADS)

    Quinton, John; Hardy, Robert; Pates, Jacqueline; James, Michael

    2017-04-01

    Understanding where sediment originates from and where it travels to, in what quantities and at which rate is at the heart of many questions surrounding sediment transport. Progress towards unravelling these questions and deepening our understanding has come from a wide range of approaches, including laboratory and field experiments conducted at a variety of scales. In seeking to understand the connectivity of sources and sinks of sediment scientists have spent considerable energy in developing tracing technologies. These have included numerous studies that have relied on the chemical properties of the soil and sediment to establish source-sink connectivity, and the use of 137Ceasium, from radioactive fall-out, to map sediment redistribution. More recently there has been an upsurge in interest in the use of artificially applied soil tracers, including rare earth element oxides and magnetic minerals. However all these tracing methods have a significant drawback: they rely on the collection of samples to assess their concentration. This means that their spatial distribution cannot easily be established in situ and that the environment that is being studied is damaged by the sampling process; nor can data be collected in real time which allows a dynamic understanding of erosion and transport processes to be developed. Here we report on the field application of a fluorescent sand sized tracer at the hillslope scale during a tillage erosion experiment. Here we trialled both intensity based and particle counting methodologies for tracer enumeration. After simulating seven years of tillage on a hillslope we were able to precisely determine the distribution of the fluorescent tracer and also its incorporation and distribution within the soil profile. Single grains of tracer could be found over 35 m from the insertion point. In a second abstract we report on an application that combines novel fluorescent videography techniques with custom image processing to trace the motion of the fluorescent soil particles under rainfall. We demonstrate the tracking of multiple sub-millimetre particles simultaneously, establishing their position 50 times a second with submillimetre precision. From this we are able to visualise and quantify parameters such as distance and direction of travel.

  20. Development of a Widely Usable Amino Acid Tracer: ⁷⁶Br-α-Methyl-Phenylalanine for Tumor PET Imaging.

    PubMed

    Hanaoka, Hirofumi; Ohshima, Yasuhiro; Suzuki, Yurika; Yamaguchi, Aiko; Watanabe, Shigeki; Uehara, Tomoya; Nagamori, Shushi; Kanai, Yoshikatsu; Ishioka, Noriko S; Tsushima, Yoshito; Endo, Keigo; Arano, Yasushi

    2015-05-01

    Radiolabeled amino acids are superior PET tracers for the imaging of malignant tumors, and amino acids labeled with (76)Br, an attractive positron emitter because of its relatively long half-life (16.2 h), could potentially be a widely usable tumor imaging tracer. In this study, in consideration of its stability and tumor specificity, we designed two (76)Br-labeled amino acid derivatives, 2-(76)Br-bromo-α-methyl-l-phenylalanine (2-(76)Br-BAMP) and 4-(76)Br-bromo-α-methyl-l-phenylalanine (4-(76)Br-BAMP), and investigated their potential as tumor imaging agents. Both (76)Br- and (77)Br-labeled amino acid derivatives were prepared. We performed in vitro and in vivo stability studies and cellular uptake studies using the LS180 colon adenocarcinoma cell line. Biodistribution studies in normal mice and in LS180 tumor-bearing mice were performed, and the tumors were imaged with a small-animal PET scanner. Both (77)Br-BAMPs were stable in the plasma and in the murine body. Although both (77)Br-BAMPs were taken up by LS180 cells and the uptake was inhibited by L-type amino acid transporter 1 inhibitors, 2-(77)Br-BAMP exhibited higher uptake than 4-(77)Br-BAMP. In the biodistribution studies, 2-(77)Br-BAMP showed more rapid blood clearance and lower renal accumulation than 4-(77)Br-BAMP. More than 90% of the injected radioactivity was excreted in the urine by 6 h after the injection of 2-(77)Br-BAMP. High tumor accumulation of 2-(77)Br-BAMP was observed in tumor-bearing mice, and PET imaging with 2-(76)Br-BAMP enabled clear visualization of the tumors. 2-(77)Br-BAMP exhibited preferred pharmacokinetics and high LS180 tumor accumulation, and 2-(76)Br-BAMP enabled clear visualization of the tumors by PET imaging. These findings suggest that 2-(76)Br-BAMP could constitute a potential new PET tracer for tumor imaging and may eventually enable the wider use of amino acid tracers. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  1. (210)Pb as a tracer of soil erosion, sediment source area identification and particle transport in the terrestrial environment.

    PubMed

    Matisoff, Gerald

    2014-12-01

    Although (137)Cs has been used extensively to study soil erosion and particle transport in the terrestrial environment, there has been much less work using excess or unsupported (210)Pb ((210)Pbxs) to study the same processes. Furthermore, since (137)Cs activities in soils are decreasing because of radioactive decay, some locations have an added complication due to the addition of Chernobyl-derived (137)Cs, and the activities of (137)Cs in the southern hemisphere are low, there is a need to develop techniques that use (210)Pbxs to provide estimates of rates of soil erosion and particle transport. This paper reviews the current status of (210)Pbxs methods to quantify soil erosion rates, to identify and partition suspended sediment source areas, and to determine the transport rates of particles in the terrestrial landscape. Soil erosion rates determined using (210)Pbxs are based on the unsupported (210)Pb ((210)Pbxs) inventory in the soil, the depth distribution of (210)Pbxs, and a mass balance calibration ('conversion model') that relates the soil inventory to the erosion rate using a 'reference site' at which neither soil erosion nor soil deposition has occurred. In this paper several different models are presented to illustrate the effects of different model assumptions such as the timing, depth and rates of the surface soil mixing on the calculated erosion rates. The suitability of model assumptions, including estimates of the depositional flux of (210)Pbxs to the soil surface and the post-depositional mobility of (210)Pb are also discussed. (210)Pb can be used as one tracer to permit sediment source area identification. This sediment 'fingerprinting' has been extended far beyond using (210)Pb as a single radioisotope to include numerous radioactive and stable tracers and has been applied to identifying the source areas of suspended sediment based on underlying rock type, land use (roads, stream banks, channel beds, cultivated or uncultivated lands, pasture lands, forested lands, construction sites, undisturbed lands) or style of erosion (sheet wash, rills, bank). The transport time of particles in the terrestrial system can be estimated using (7)Be/(210)Pbxs radionuclide ratios and from mass balance models of (210)Pbxs and/or (7)Be in streams. Watershed residence times can be calculated from the radionuclide inventory and the erosional loss rate. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Exploring atmospheric radon with airborne gamma-ray spectroscopy

    NASA Astrophysics Data System (ADS)

    Baldoncini, Marica; Albéri, Matteo; Bottardi, Carlo; Minty, Brian; Raptis, Kassandra G. C.; Strati, Virginia; Mantovani, Fabio

    2017-12-01

    222Rn is a noble radioactive gas produced along the 238U decay chain, which is present in the majority of soils and rocks. As 222Rn is the most relevant source of natural background radiation, understanding its distribution in the environment is of great concern for investigating the health impacts of low-level radioactivity and for supporting regulation of human exposure to ionizing radiation in modern society. At the same time, 222Rn is a widespread atmospheric tracer whose spatial distribution is generally used as a proxy for climate and pollution studies. Airborne gamma-ray spectroscopy (AGRS) always treated 222Rn as a source of background since it affects the indirect estimate of equivalent 238U concentration. In this work the AGRS method is used for the first time for quantifying the presence of 222Rn in the atmosphere and assessing its vertical profile. High statistics radiometric data acquired during an offshore survey are fitted as a superposition of a constant component due to the experimental setup background radioactivity plus a height dependent contribution due to cosmic radiation and atmospheric 222Rn. The refined statistical analysis provides not only a conclusive evidence of AGRS 222Rn detection but also a (0.96 ± 0.07) Bq/m3 222Rn concentration and a (1318 ± 22) m atmospheric layer depth fully compatible with literature data.

  3. Metabolism and Disposition of Aditoprim in Swine, Broilers, Carp and Rats

    NASA Astrophysics Data System (ADS)

    Wang, Liye; Huang, Lingli; Pan, Yuanhu; Kuča, Kamil; Klímová, Blanka; Wu, Qinghua; Xie, Shuyu; Ahmad, Ijaz; Chen, Dongmei; Tao, Yanfei; Wan, Dan; Liu, Zhenli; Yuan, Zonghui

    2016-02-01

    Aditoprim (ADP) is a newly developed antibacterial agent in veterinary medicine. The metabolism and disposition of ADP in swine, broilers, carp and rats were investigated by using a radio tracer method combined with a radioactivity detector and a liquid chromatography/ion trap/time-of-flight mass spectrometry. After a single oral administration, more than 94% of the dose was recovered within 14 d in the four species. The urine excretion was dominant in swine and rats, making up 78% of the dose. N-monodesmethyl-ADP, N-didesmethyl-ADP, and 10 new metabolites were characterized. These metabolites were biotransformed from the process of demethylation, α-hydroxylation, N-oxidation, and NH2-glucuronidation. After an oral dose for 7 d, ADP-derived radioactivity was widely distributed in tissues, and high concentrations were especially observed in bile, liver, kidney, lung, and spleen. The radioactivity in the liver was eliminated much more slowly than in other tissues, with a half-life of 4.26, 3.38, 6.69, and 5.21 d in swine, broilers, carp, and rats, respectively. ADP, N-monodesmethyl-ADP, and N-didesmethyl-ADP were the major metabolites in edible tissues. Notably, ADP was detected with the highest concentration and the longest duration in these tissues. These findings indicated that ADP is the marker residue and the liver is the residue target tissue.

  4. Triacylglycerol secretion in rats: validation of a tracer method employing radioactive glycerol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bird, M.; Williams, M.A.; Baker, N.

    1984-10-01

    A two-compartment model was developed to analyze the temporal changes in plasma triacylglycerol (TG)-specific radioactivity after injection of (2-/sup 3/H)glycerol into rats. The analysis, which yielded fractional rate constants of TG secretion, was tested in rats fed diets either adequate or deficient in essential fatty acids (EFA) and containing either glucose, fructose or sucrose as the dietary carbohydrate. The method of analysis appeared valid, first, because of a close agreement between experimental and computer-fitted TG-specific radioactivity curves, and second, because the fractional rate constants obtained were quite similar to fractional rate constants determined previously by the Triton WR-1339 technique inmore » rats maintained on identical diets. The results show that EFA deficiency increased the fractional rate constant of TG secretion 1.7-, 1.8- and 3.3-fold and the rate of TG secretion 1.8-, 1.6- and 1.4-fold when the dietary carbohydrate was glucose, sucrose and fructose, respectively, in comparison with control rats fed diets supplying these same carbohydrates but adequate in EFA. In the latter groups, the rates of plasma TG secretion were in the range of 0.14-0.17 mg/min per 100 g body weight, and the rate of secretion in the fructose-fed rats was only 20% higher than in the glucose-fed rats.« less

  5. Metabolism and Disposition of Aditoprim in Swine, Broilers, Carp and Rats

    PubMed Central

    Wang, Liye; Huang, Lingli; Pan, Yuanhu; Kuča, Kamil; Klímová, Blanka; Wu, Qinghua; Xie, Shuyu; Ahmad, Ijaz; Chen, Dongmei; Tao, Yanfei; Wan, Dan; Liu, Zhenli; Yuan, Zonghui

    2016-01-01

    Aditoprim (ADP) is a newly developed antibacterial agent in veterinary medicine. The metabolism and disposition of ADP in swine, broilers, carp and rats were investigated by using a radio tracer method combined with a radioactivity detector and a liquid chromatography/ion trap/time-of-flight mass spectrometry. After a single oral administration, more than 94% of the dose was recovered within 14 d in the four species. The urine excretion was dominant in swine and rats, making up 78% of the dose. N-monodesmethyl-ADP, N-didesmethyl-ADP, and 10 new metabolites were characterized. These metabolites were biotransformed from the process of demethylation, α-hydroxylation, N-oxidation, and NH2-glucuronidation. After an oral dose for 7 d, ADP-derived radioactivity was widely distributed in tissues, and high concentrations were especially observed in bile, liver, kidney, lung, and spleen. The radioactivity in the liver was eliminated much more slowly than in other tissues, with a half-life of 4.26, 3.38, 6.69, and 5.21 d in swine, broilers, carp, and rats, respectively. ADP, N-monodesmethyl-ADP, and N-didesmethyl-ADP were the major metabolites in edible tissues. Notably, ADP was detected with the highest concentration and the longest duration in these tissues. These findings indicated that ADP is the marker residue and the liver is the residue target tissue. PMID:26838160

  6. Geohydrologic and drill-hole data for test well USW H-4, Yucca Mountain, Nye County, Nevada

    USGS Publications Warehouse

    Whitfield, M.S.; Thordarson, William; Eshom, E.P.

    1984-01-01

    Data are presented on drilling operations, lithology, geophysical well logs, sidewall-core samples, water-level monitoring, pumping tests, injection tests, radioactive-tracer borehole flow survey, and water chemistry for test well USW H-4. The well is one of a series of test wells drilled in the southwestern part of the Nevada Test Site, Nye County, Nevada, in cooperation with the U.S. Department of Energy. These test wells are part of the Nevada Nuclear Waste Storage Investigations to identify sites for storage of high-level radioactive wastes. Test well USW H-4 was drilled in ash-flow tuff to a total depth of 1,219 meters. Depth to water below land surface was 519 meters or at an altitude of 730 meters above sea level. After test pumping at a rate of 17.4 liters per second for approximately 9 days, the drawdown was 4.85 meters. A radioactive borehole-flow survey indicated that the Bullfrog Member was the most productive geologic unit, producing 36.5 percent of the water in the well. The second most productive geologic unit was the Tram Member, which produced 32 percent of the water. The water in test well USW H-4 is predominantly a soft, sodium bicarbonate type of water typical of water produced in tuffaceous rocks in southern Nevada. (USGS)

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosendahl, S., E-mail: rosendahl@wwu.de; Brown, E.; Fieguth, A.

    The separation of krypton and xenon is of particular importance for the field of direct dark matter search with liquid xenon detectors. The intrinsic contamination of the xenon with radioactive {sup 85}Kr makes a significant background for these kinds of low count-rate experiments and has to be removed beforehand. This can be achieved by cryogenic distillation, a technique widely used in industry, using the different vapor pressures of krypton and xenon. In this paper, we present an investigation on the separation performance of a single stage distillation system using a radioactive {sup 83m}Kr-tracer method. The separation characteristics under different operationmore » conditions are determined for very low concentrations of krypton in xenon at the level of {sup 83m}Kr/Xe = 1.9 ⋅ 10{sup −15}, demonstrating, that cryogenic distillation in this regime is working. The observed separation is in agreement with the expectation from the different volatilities of krypton and xenon. This cryogenic distillation station is the first step on the way to a multi-stage cryogenic distillation column for the next generation of direct dark matter experiment XENON1T.« less

  8. Radionuclides, radiotracers and radiopharmaceuticals for in vivo diagnosis

    NASA Astrophysics Data System (ADS)

    Wiebe, Leonard I.

    Radioactive tracers for in vivo clinical diagnosis fall within a narrow, strictly-defined set of specifications in respect of their physical properties, chemical and biochemical characteristics, and (approved) medical applications. The type of radioactive decay and physical half-life of the radionuclide are immutable properties which, along with the demands of production and supply, limit the choice of radionuclides used in medicine to only a small fraction of those known to exist. In use, the biochemical and physiological properties of a radiotracer are dictated by the chemical form of the radionuclide. This chemical form may range from elemental, molecular or ionic, to complex compounds formed by coordinate or covalent bonding of the radionuclide to either simple organic or inorganic molecules, or complex macromolecules. Few of the radiotracers which are tested in model systems ever become radiopharmaceuticals in the strictest sense. Radionuclides, radiotracers and radiopharmaceuticals in use are reviewed. Drug legislation and regulations concerning drug manufacture, as well as hospital ethical constraints and legislation concerning unsealed sources of radiation must all be satisfied in order to translate a radiopharmaceutical from the laboratory to clinical use.

  9. Safety-relevant hydrogeological properties of the claystone barrier of a Swiss radioactive waste repository: An evaluation using multiple lines of evidence

    NASA Astrophysics Data System (ADS)

    Gautschi, Andreas

    2017-09-01

    In Switzerland, the Opalinus Clay - a Jurassic (Aalenian) claystone formation - has been proposed as the first-priority host rock for a deep geological repository for both low- and intermediate-level and high-level radioactive wastes. An extensive site and host rock investigation programme has been carried out during the past 30 years in Northern Switzerland, comprising extensive 2D and 3D seismic surveys, a series of deep boreholes within and around potential geological siting regions, experiments in the international Mont Terri Rock Laboratory, compilations of data from Opalinus Clay in railway and motorway tunnels and comparisons with similar rocks. The hydrogeological properties of the Opalinus Clay that are relevant from the viewpoint of long-term safety are described and illustrated. The main conclusions are supported by multiple lines of evidence, demonstrating consistency of conclusions based on hydraulic properties, porewater chemistry, distribution of natural tracers across the Opalinus Clay as well as small- and large-scale diffusion models and the derived conceptual understanding of solute transport.

  10. A bacteria antibiotic system in space (23-F ANTIBIO)

    NASA Technical Reports Server (NTRS)

    Tixador, Rene; Gasset, G.; Eche, B.; Moatti, N.; Lapchine, L.; Woldringh, C.; Toorop, P.; Moatti, J. P.; Delmotte, F.; Tap, G.

    1995-01-01

    In order to evaluate the effects of weightlessness and cosmic radiations on the bacteria resistance to antibiotics, the Antibio 23F experiment was undertaken onboard Discovery during the 1st International Microgravity Laboratory (IML-1) mission. The effects of various antibiotic concentrations (dihydrostreptomycin) on Escherichia coli growth and cell division behavior were studied. The antibiotic binding was investigated using a radioactive tracer (tritium). The results showed that microgravity did not affect E. coli cells in regards the growth and the cell division. The antibiotic added to the culture medium induced an inhibition of the cultures both in the flight and ground controls. However, the antibiotic was less efficient in flight. The behavior of bacteria was modified, and the exponential growth rate was increased in flight. The incorporation of radioactive antibiotics in flight was comparatively different to ground incorporation, which indicated some perturbations in antibiotic binding. The experiments performed in the 1 g centrifuge did not show any difference in the cultures developed on the static rack, and could support a radiative effect of cosmic radiation to explain the results.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, R.B.; Gessel, S.P.; Held, E.E.

    During the 1950`s and 1960`s, the Laboratory of Radiation Biology at the University of Washington carried out an intensive study of this Atoll, which was contaminated with radioactive fallout from the {open_quotes}Bravo shot{close_quotes} in 1954. This study involved many aspects of the environment and the plant and animal life: soils, land plants, marine life, birds, geology and hydrology, and human diets as well. In much of the research, the fortuitiously present radioactive isotopes, especially {sup 137}Cs and {sup 90}Sr, were tracers. Although the term {open_quotes}ecosystem study{close_quotes} was not in vogue at that time, it is clear that this was anmore » early use of the ecosystem approach. Soil types and their development, the distribution of mineral elements in plants and soils, including predominant radionuclides, distribution and growth of native terrestrial plants in relation to topography and salinity, some aspects of the human diets, micronutrient nutrition of the coconut palm, island and islet development and stability, were given attention in the studies. Some of the findings in the various areas of study will be presented and discussed. 32 refs., 2 figs., 8 tabs.« less

  12. Coagulation effect on the activity size distributions of long lived radon progeny aerosols and its application to atmospheric residence time estimation techniques.

    PubMed

    Anand, S; Mayya, Y S

    2015-03-01

    The long lived naturally occurring radon progeny species in the atmosphere, namely (210)Pb, (210)Bi and (210)Po, have been used as important tracers for understanding the atmospheric mixing processes and estimating aerosol residence times. Several observations in the past have shown that the activity size distribution of these species peaks at larger particle sizes as compared to the short lived radon progeny species - an effect that has been attributed to the process of coagulation of the background aerosols to which they are attached. To address this issue, a mathematical equation is derived for the activity-size distribution of tracer species by formulating a generalized distribution function for the number of tracer atoms present in coagulating background particles in the presence of radioactive decay and removal. A set of these equations is numerically solved for the progeny chain using Fuchs coagulation kernel combined with a realistic steady-state aerosol size spectrum that includes nucleation, accumulation and coarse mode components. The important findings are: (i) larger shifts in the modal sizes of (210)Pb and (210)Po at higher aerosol concentrations such as that found in certain Asian urban regions (ii) enrichment of tracer specific activity on particles as compared to that predicted by pure attachment laws (iii) sharp decline of daughter-to-parent activity ratios for decreasing particle sizes. The implication of the results to size-fractionated residence time estimation techniques is highlighted. A coagulation corrected graphical approach is presented for estimating the residence times from the size-segregated activity ratios of (210)Bi and (210)Po with respect to (210)Pb. The discrepancy between the residence times predicted by conventional formula and the coagulation corrected approach for specified activity ratios increases at higher atmospheric aerosol number concentrations (>10(10) #/m(3)) for smaller sizes (<1 μm). The results are further discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. THM large spatial-temporal model to simulate the past 2 Ma hydrogeological evolution of Paris Basin including natural tracer transport as part of site characterization for radwaste repository project Cigéo - France

    NASA Astrophysics Data System (ADS)

    Benabderrahmane, A., Sr.

    2017-12-01

    Hydrogeological site characterization for deep geological high level and intermediate level long lived radioactive waste repository cover a large time scale needed for safety analysis and calculation. Hydrogeological performance of a site relies also on the effects of geodynamic evolution as tectonic uplift, erosion/sedimentation and climate including glaciation on the groundwater flow and solute and heat transfer. Thermo-Hydro-Mechanical model of multilayered aquifer system of Paris Basin is developed to reproduce the present time flow and the natural tracer (Helium) concentration profiles based on the last 2 Ma of geodynamic evolution. Present time geological conceptual model consist of 27 layers at Paris Basin (Triassic-Tertiary) with refinement at project site scale (29 layers from Triassic to Portlandian). Target layers are the clay host formation of Callovo-Oxfrodian age (160 Ma) and the surrounding aquifer layers of Oxfordian and Dogger. Modelled processes are: groundwater flow, heat and solutes (natural tracers) transport, freezing and thawing of groundwater (expansion and retreat of permafrost), deformation of the multilayered aquifer system induced by differential tectonic uplift and the hydro-mechanical stress effect as caused by erosion of the outcropping layers. Numerical simulation considers a period from 2 Ma BP and up to the present. Transient boundary conditions are governed by geodynamic processes: (i) modification of the geometry of the basin and (ii) temperatures along the topography will change according to a series of 15 identical climate cycles with multiple permafrost (glaciation) periods. Numerical model contains 71 layers and 18 million cells. The solution procedure solves three coupled systems of equations, head, temperature and concentrations, by the use of a finite difference method, and by applying extensive parallel processing. The major modelling results related to the processes of importance for site characterization as hydraulic head distribution, flow velocity, heat and natural tracer transport impacted by geodynamic past evolution are discussed.

  14. The influence of nepheloid layers on global model simulations of 231Pa and 230Th.

    NASA Astrophysics Data System (ADS)

    Basak, C.; Plancherel, Y.; Khatiwala, S.; Anderson, R. F.

    2016-12-01

    231Pa and 230Th in the ocean are produced at a constant ratio by Uranium decay but adsorption onto particles removes these tracers differentially. This fractionation process makes it possible to use the elemental 231Pa/230Th ratio as a paleoceanography proxy, frequently used for deriving the strength of Atlantic Meridional Overturning Circulation. The removal process, however, is further complicated by the abundance and composition of the available particle types. Understanding how dissolved tracers interact with the particle field in the ocean is key to better understand the biogeochemical cycling of these particle-reactive elements and their use as a flux tracer in present and past oceans. We here present simulations of the 231Pa/230Th ratio using the Transport Matrix Method (TMM, Khatiwala, 2007), focusing especially on the role of the nepheloid layer in controlling the distribution of these radiotracers. The model simulates each tracer separately, with advective-diffusive transport based on the ECCO ocean state estimate (Stammer et al., 2004). Sources include production by Uranium decay and dust dissolution. Radioactive decay and importantly, reversible scavenging and sedimentation are the main sinks that control the removal of the radiotracers. Similar to previous studies, we consider particle fields consisting of calcium carbonate, opal, particle organic matter, and dust. A novelty is that we explicitly consider the influence of an additional bottom particle layer (nepheloid). Simulations that include a nepheloid layer produce vertical profiles that better fit the observed distribution of 230Th and 231Pa. Specifically, observational data in the South Atlantic and eastern South Pacific indicate a mid-depth inflection (for both Pa and Th), a feature that can only be obtained if a nepheloid layer is included in the simulation. Our simulations reinforce the idea that nepheloid layers play an important role in Pa and Th cycling in the ocean (Deng et al., 2014; Hayes et al., 2015).

  15. WE-H-207A-06: Hypoxia Quantification in Static PET Images: The Signal in the Noise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keller, H; Yeung, I; Milosevic, M

    2016-06-15

    Purpose: Quantification of hypoxia from PET images is of considerable clinical interest. In the absence of dynamic PET imaging the hypoxic fraction (HF) of a tumor has to be estimated from voxel values of activity concentration of a radioactive hypoxia tracer. This work is part of an effort to standardize quantification of tumor hypoxic fraction from PET images. Methods: A simple hypoxia imaging model in the tumor was developed. The distribution of the tracer activity was described as the sum of two different probability distributions, one for the normoxic (and necrotic), the other for the hypoxic voxels. The widths ofmore » the distributions arise due to variability of the transport, tumor tissue inhomogeneity, tracer binding kinetics, and due to PET image noise. Quantification of HF was performed for various levels of variability using two different methodologies: a) classification thresholds between normoxic and hypoxic voxels based on a non-hypoxic surrogate (muscle), and b) estimation of the (posterior) probability distributions based on maximizing likelihood optimization that does not require a surrogate. Data from the hypoxia imaging model and from 27 cervical cancer patients enrolled in a FAZA PET study were analyzed. Results: In the model, where the true value of HF is known, thresholds usually underestimate the value for large variability. For the patients, a significant uncertainty of the HF values (an average intra-patient range of 17%) was caused by spatial non-uniformity of image noise which is a hallmark of all PET images. Maximum likelihood estimation (MLE) is able to directly optimize for the weights of both distributions, however, may suffer from poor optimization convergence. For some patients, MLE-based HF values showed significant differences to threshold-based HF-values. Conclusion: HF-values depend critically on the magnitude of the different sources of tracer uptake variability. A measure of confidence should also be reported.« less

  16. Use of metaiodobenzylguanidine (MIBG) in pneumology.

    PubMed

    Giordano, A; Calcagni, M L; Rossi, B; Rufini, V; Fuso, L; Valente, S; Pistelli, R; Franceschini, R; Troncone, L

    1995-12-01

    Norepinephrine (NE) is one of the many biologically active substances that are metabolized by the lung. The norepinephrine uptake in the lung has been widely investigated in animal studies in order to detect abnormalities of the endothelial cells. 131I- or 123I-labelled metaiodobenzylguanidine (MIBG) is a radioactive tracer that shares several metabolic pathways with NE; it has been used instead NE or both in animal and in human studies for the same purposes. It has been definitely demonstrated that MIBG lung uptake following intravenous administration is a reliable marker of minimal endothelial cell lesions and it allows one to investigate several conditions involving damage to the lung vasculature such as adult respiratory distress syndrome, post-actinic lung fibrosis or chemotherapic lung toxicity. MIBG could also potentially be used as a tracer of the neuroadrenergic system of the airways, once it has been deposited in the whole branches of the bronchial tree. With this in mind we evaluated the feasibility of the administration of MIBG in radioaerosol form. We first performed a chromatographic study on [123I]MIBG aliquots aerosolized for variable lengths of time (2-30 minutes). Radiochemical purity was always over 96%, thus demonstrating that aerosolization does not significantly modify the stability of the tracer. We then compared both the lung clearance curves and the scintigraphic images in two groups of normal subjects who respectively underwent [123I]MIBG and 99mTc-DTPA radioaerosol dynamic scintigraphy. We found that MIBG clearance to be significantly lower than that of DTPA (135 +/- 32 minutes versus 69 +/- 27 minutes, p < 0.01), probably due to its being trapped in the adrenergic nerve endings of the airways. The pulmonary distribution of both tracers was homogeneous, as demonstrated by the correspondence of the values for the aerosol penetration index in both groups of subjects. Such results warrant further research and pharmacologic tests.

  17. Geochemical cycling, mass balance, and Earth’s dynamic structure (Invited)

    NASA Astrophysics Data System (ADS)

    Allegre, C. J.

    2009-12-01

    The use of radiogenic tracers is now established as one of the standard methods (together with seismic tomography) to constrain Earth models. One of the advantages of radiogenic tracers is that they constrain not only present day structures, but also their historical evolution since the earliest time. A mandatory condition is to use not only one but all of the available isotopic systems, with their diverse cycling properties and different radioactive half-lives. Mass balances calculations are the basic tool which allows one to use quantitatively the various tracers. However, the inverse method approach, when applied to mass balance, is strongly non-linear, particularly for tracers with intermediate to short half lives. 142Nd, 82W, and 129Xe allows one to define a consistent model for the Present and past evolutions. Results point to a 3-layer model for the present mantle: an upper mantle with two layers separated by the 450 km discontinuity, and a lower mantle below the 670 km discontinuity. These layers all convect independently though none of them is fully isolated. They exchange matter and energy, not necessarily through the same process. For instance, most hotspots (though not all of them!) are boundary layer instabilities generated at the 670 km discontinuity, but there is important heat transfer from the lower mantle through megablobs. Recent results on the Hadean period are in agreement with core-mantle- atmosphere differentiation at 4444 My. The early crust was mostly anorthositic but has been recycled into the upper mantle within the first billion years. Formation of granitic continents started at 4300 My. 80% of their material was already present on the surface as acidic rocks by 2500 My. The reworking process involved in continental development increased continuously with time and today is the dominant process. Continents are now in a stage of steady state, with general addition of mantle and subducted continental material.

  18. Simulations of the transport and deposition of 137Cs over Europe after the Chernobyl NPP accident: influence of varying emission-altitude and model horizontal and vertical resolution

    NASA Astrophysics Data System (ADS)

    Evangeliou, N.; Balkanski, Y.; Cozic, A.; Møller, A. P.

    2013-03-01

    The coupled model LMDzORINCA has been used to simulate the transport, wet and dry deposition of the radioactive tracer 137Cs after accidental releases. For that reason, two horizontal resolutions were deployed and used in the model, a regular grid of 2.5°×1.25°, and the same grid stretched over Europe to reach a resolution of 0.45°×0.51°. The vertical dimension is represented with two different resolutions, 19 and 39 levels, respectively, extending up to mesopause. Four different simulations are presented in this work; the first uses the regular grid over 19 vertical levels assuming that the emissions took place at the surface (RG19L(S)), the second also uses the regular grid over 19 vertical levels but realistic source injection heights (RG19L); in the third resolution the grid is regular and the vertical resolution 39 vertical levels (RG39L) and finally, it is extended to the stretched grid with 19 vertical levels (Z19L). The best choice for the model validation was the Chernobyl accident which occurred in Ukraine (ex-USSR) on 26 May 1986. This accident has been widely studied since 1986, and a large database has been created containing measurements of atmospheric activity concentration and total cumulative deposition for 137Cs from most of the European countries. According to the results, the performance of the model to predict the transport and deposition of the radioactive tracer was efficient and accurate presenting low biases in activity concentrations and deposition inventories, despite the large uncertainties on the intensity of the source released. However, the best agreement with observations was obtained using the highest horizontal resolution of the model (Z19L run). The model managed to predict the radioactive contamination in most of the European regions (similar to Atlas), and also the arrival times of the radioactive fallout. As regards to the vertical resolution, the largest biases were obtained for the 39 layers run due to the increase of the levels in conjunction with the uncertainty of the source term. Moreover, the ecological half-life of 137Cs in the atmosphere after the accident ranged between 6 and 9 days, which is in good accordance to what previously reported and in the same range with the recent accident in Japan. The high response of LMDzORINCA model for 137Cs reinforces the importance of atmospheric modeling in emergency cases to gather information for protecting the population from the adverse effects of radiation.

  19. Simulations of the transport and deposition of 137Cs over Europe after the Chernobyl Nuclear Power Plant accident: influence of varying emission-altitude and model horizontal and vertical resolution

    NASA Astrophysics Data System (ADS)

    Evangeliou, N.; Balkanski, Y.; Cozic, A.; Møller, A. P.

    2013-07-01

    The coupled model LMDZORINCA has been used to simulate the transport, wet and dry deposition of the radioactive tracer 137Cs after accidental releases. For that reason, two horizontal resolutions were deployed and used in the model, a regular grid of 2.5° × 1.27°, and the same grid stretched over Europe to reach a resolution of 0.66° × 0.51°. The vertical dimension is represented with two different resolutions, 19 and 39 levels respectively, extending up to the mesopause. Four different simulations are presented in this work; the first uses the regular grid over 19 vertical levels assuming that the emissions took place at the surface (RG19L(S)), the second also uses the regular grid over 19 vertical levels but realistic source injection heights (RG19L); in the third resolution the grid is regular and the vertical resolution 39 levels (RG39L) and finally, it is extended to the stretched grid with 19 vertical levels (Z19L). The model is validated with the Chernobyl accident which occurred in Ukraine (ex-USSR) on 26 May 1986 using the emission inventory from Brandt et al. (2002). This accident has been widely studied since 1986, and a large database has been created containing measurements of atmospheric activity concentration and total cumulative deposition for 137Cs from most of the European countries. According to the results, the performance of the model to predict the transport and deposition of the radioactive tracer was efficient and accurate presenting low biases in activity concentrations and deposition inventories, despite the large uncertainties on the intensity of the source released. The best agreement with observations was obtained using the highest horizontal resolution of the model (Z19L run). The model managed to predict the radioactive contamination in most of the European regions (similar to De Cort et al., 1998), and also the arrival times of the radioactive fallout. As regards to the vertical resolution, the largest biases were obtained for the 39 layers run due to the increase of the levels in conjunction with the uncertainty of the source term. Moreover, the ecological half-life of 137Cs in the atmosphere after the accident ranged between 6 and 9 days, which is in good accordance to what previously reported and in the same range with the recent accident in Japan. The high response of LMDZORINCA model for 137Cs reinforces the importance of atmospheric modelling in emergency cases to gather information for protecting the population from the adverse effects of radiation.

  20. Organo-iodine formation in soils and aquifer sediments at ambient concentrations.

    PubMed

    Schwehr, K A; Santschi, P H; Kaplan, D J; Yeager, C M; Brinkmeyer, R

    2009-10-01

    One of the key risk drivers at radioactive waste disposal facilities is radioiodine, especially 129I. As iodine mobility varies greatly with iodine speciation, experiments with 129I-contaminated aquifer sediments from the Savannah River Site located in Aiken, SC, were carried out to test iodine interactions with soils and aquifer sediments. Using tracer 125I- and stable 127I- additions, it was shown that such interactions were highly dependent on I- concentrations added to sediment suspensions, contact time with the sediment, and organic carbon (OC) content, resulting in an empirical particle-water partition coefficient (Kd) that was an inverse power function of the added I- concentration. However, Kd values of organically bound 127I were 3 orders of magnitude higher than those determined after 1-2 weeks of tracer equilibration, approaching those of OC. Under ambient conditions, organo-iodine (OI) was a major fraction (67%) of the total iodine in the dissolved phase and by implication of the particulate phase. As the total concentration of amended I- increased, the fraction of detectable dissolved OI decreased. This trend, attributed to OC becoming the limiting factor in the aquifer sediment explains why at elevated I-concentrations OI is often not detected.

  1. Image navigation as a means to expand the boundaries of fluorescence-guided surgery

    NASA Astrophysics Data System (ADS)

    Brouwer, Oscar R.; Buckle, Tessa; Bunschoten, Anton; Kuil, Joeri; Vahrmeijer, Alexander L.; Wendler, Thomas; Valdés-Olmos, Renato A.; van der Poel, Henk G.; van Leeuwen, Fijs W. B.

    2012-05-01

    Hybrid tracers that are both radioactive and fluorescent help extend the use of fluorescence-guided surgery to deeper structures. Such hybrid tracers facilitate preoperative surgical planning using (3D) scintigraphic images and enable synchronous intraoperative radio- and fluorescence guidance. Nevertheless, we previously found that improved orientation during laparoscopic surgery remains desirable. Here we illustrate how intraoperative navigation based on optical tracking of a fluorescence endoscope may help further improve the accuracy of hybrid surgical guidance. After feeding SPECT/CT images with an optical fiducial as a reference target to the navigation system, optical tracking could be used to position the tip of the fluorescence endoscope relative to the preoperative 3D imaging data. This hybrid navigation approach allowed us to accurately identify marker seeds in a phantom setup. The multispectral nature of the fluorescence endoscope enabled stepwise visualization of the two clinically approved fluorescent dyes, fluorescein and indocyanine green. In addition, the approach was used to navigate toward the prostate in a patient undergoing robot-assisted prostatectomy. Navigation of the tracked fluorescence endoscope toward the target identified on SPECT/CT resulted in real-time gradual visualization of the fluorescent signal in the prostate, thus providing an intraoperative confirmation of the navigation accuracy.

  2. Hybrid surgical guidance based on the integration of radionuclear and optical technologies

    PubMed Central

    Valdés-Olmos, Renato; Buckle, Tessa; Vidal-Sicart, Sergi

    2016-01-01

    With the evolution of imaging technologies and tracers, the applications for nuclear molecular imaging are growing rapidly. For example, nuclear medicine is increasingly being used to guide surgical resections in complex anatomical locations. Here, a future workflow is envisioned that uses a combination of pre-operative diagnostics, navigation and intraoperative guidance. Radioguidance can provide means for pre-operative and intraoperative identification of “hot” lesions, forming the basis of a virtual data set that can be used for navigation. Luminescence guidance has shown great potential in the intraoperative setting by providing optical feedback, in some cases even in real time. Both of these techniques have distinct drawbacks, which include inaccuracy in areas that contain a background signal (radioactivity) or a limited degree of signal penetration (luminescence). We, and others, have reasoned that hybrid/multimodal approaches that integrate the use of these complementary modalities may help overcome their individual weaknesses. Ultimately, this will lead to advancement of the field of interventional molecular imaging/image-guided surgery. In this review, an overview of clinically applied hybrid surgical guidance technologies is given, whereby the focus is placed on tracers and hardware. PMID:26943463

  3. Determinants of [13N]ammonia kinetics in hepatic PET experiments: a minimal recirculatory model.

    PubMed

    Weiss, Michael; Roelsgaard, Klaus; Bender, Dirk; Keiding, Susanne

    2002-12-01

    The aim of this study was the development of a modelling approach for the analysis of the systemic kinetics of the tracer nitrogen-13 ammonia administered for dynamic liver scanning. The radioactive half-life of this tracer is 9.8 min, which limits the time span in which data are available in a positron emission tomography experimental setting. A circulatory pharmacokinetic model was applied to the metabolism of ammonia in anaesthetised pigs, which incorporated data from serial measurements of [(13)N]ammonia and [(13)N]metabolite activity in arterial and portal venous blood together with blood flow rates through the portal vein and through the hepatic artery obtained over 20 min after intravenous injection of [(13)N]ammonia. Model analysis showed that up to 20 min after injection the time course of [(13)N]ammonia concentration in arterial blood is primarily determined by distribution kinetics (steady-state volume of distribution 1,856+/-531 ml kg(-1)). Simultaneous fitting of arterial ammonia and metabolite blood concentrations allowed for estimation of the hepatic [(13)N]ammonia clearance (10.25+/-1.84 ml min(-1) kg(-1)), which accounted for the formation of the circulating metabolites.

  4. Old and new radionuclide presence in Romania after Chernobyl and Fukushima disasters

    NASA Astrophysics Data System (ADS)

    Cosma, Constantin; Iurian, Andra; Nita, Dan; Pantelica, Ana; Prodan, Eugen

    2013-04-01

    Our laboratory measured the radionuclide presence in Transylvania region both after Chernobyl and Fukushima accidents. The paper presents old and new data connected with these disasters obtained not only by us but also by others laboratories from Romania. It is an attempt to mark the mainly aspects regarding the radioactive contamination in our country connected with these catastrophes. After the Chernobyl accident the radioactive cloud passage over Romania on NE - SW direction brought relatively intesive radionuclide deposition. On this direction the highest deposition were found in the areas where this passage during April 30-st and May 1-st were accompanied by rainfalls. In the rain water and fresh sediment colected at May 1-st, 1986 and measured the next days, all radionuclide species from Chernobyl could be identified [1]. Additional measurements of 90Sr and 239/240Pu have been made several years later in different environmental samples (roof sediment, soil, pollen, sand, roof-water, street dust) collected in 1986 from Cluj-Napoca, Romania [2]. In the case of Fukushima disaster the air transport from west and north-west brought small quantities of radionuclides over the Romanian teritorry. Even if in this case the radioactive cloud was very dilluted, 131I could be clearly identified and measured in air, rain water and other products as: milk, vegetables, grass, fresh meat from the NW of Romania [3]. Measurements have been also conducted in Bucharest and Pitesti. During the last 5 years suplimentary 137Cs measurements were made in different areas as an attempt to use this radionuclide as soil and sediment tracer. [1]. C. Cosma, Some Aspects of Radioactive Contamination after Chernobyl Accident in Romania, J. Radioanal. Nucl. Chem., 251, 2, 221-226 (2002) [2]. C. Cosma, Strontium-90 Measurement without Chemical Separation in Samples after Chernobyl Accident, Spectrochimica Acta, Part B, 55, 1165-1171 (2000) [3]. C. Cosma, AR. Iurian, DC. Ni?, R. Begy R, C. Cîndea , Indicators of the Fukushima radioactive release in NW Romania, J Environ Radioact. 114:94-9. (2012) doi: 10.1016/j.jenvrad.2011.11.020

  5. Tracing the Origin of Radioactivity in Groundwater from the Negev, Israel

    NASA Astrophysics Data System (ADS)

    Vengosh, A.; Pery, N.; Paytan, A.; Haquin, G.; Enhanany, S.; Pankratov, I.

    2004-12-01

    In normal groundwater conditions natural radionuclides are typically retained on the aquifer matrix and their activity in the groundwater is low. Radium is exceptional since the ratio between adsorbed and dissolved radium depends the ionic strength of the solution. Under high salinity radium is rapidly desorbed and accumulates in the liquid phase. Here we report the results of a geochemical study that investigates the origin of radioactivity in brackish to saline groundwater from the Negev and Arava Valley, Israel. We use the Ra isotope quartet (226Ra-half life 1600 y, 228Ra - 5.6 y, 224Ra - 3.6 d, 223Ra - 11.4 d) to discriminate between radioactivity derived from a thorium source (high 228Ra/226Ra and 224Ra/223Ra ratios) found in groundwater flowing in the Nubian Sandstone aquifer and an uranium source (low 228Ra/226Ra and 224Ra/223Ra ratios) in groundwater flowing in carbonate (Upper Cretaceous) aquifer. We show that the activity of 226Ra in groundwater from the carbonate aquifer is positively correlated with that of the salinity. In the Nubian Sandstone aquifer, however, no such correlation was found. Instead, we observed an inverse correlation between 228Ra activity and sulfate and a positive correlation with barium contents. Given the high H2S content of the ground water, we hypothesized that sulfate reduction process triggers radium leaching to the water, probably due to barite dissolution and anoxic conditions in the aquifer. These findings indicate that high radioactivity can also be found even in low-saline groundwater and that the isotopic ratios of radium are sensitive tracers for the water-rock interactions and thus reconstructing the flow paths in different aquifer matrix (i.e., carbonate versus sandstone).

  6. Radiochemical techniques for determining some naturally occurring radionuclides in marine environmental materials

    NASA Astrophysics Data System (ADS)

    Baker, C. W.

    1984-06-01

    The determination of some of the naturally-occurring, alpha-emitting radionuclides in marine environmental materials, is of interest for several reasons. Radium and radon nuclides are potentially useful as oceanographic tracers. Lead and thorium nuclides may be used to study sedimentation rates, mixing processes and bioturbation in sediments. Radium and polonium nuclides are incorporated into food chains and the data may provide a perspective against which to assess the significance, for marine organisms, of exposure to radiation in a marine radioactive waste disposal situation. This paper discusses the manner in which samples are taken, and the radiochemical methods which have been employed to measure the nuclides, together with some data produced.

  7. Effect of Chinese Herbal Medicine on Molecular Imaging of Neurological Disorders.

    PubMed

    Yao, Yao; Chen, Ting; Huang, Jing; Zhang, Hong; Tian, Mei

    2017-01-01

    Chinese herbal medicine has been used to treat a wide variety of neurological disorders including stroke, Alzheimer's disease, and Parkinson's disease. However, its mechanism behind the effectiveness remains unclear. Recently, molecular imaging technology has been applied for this purpose, since it can assess the cellular or molecular function in a living subject by using specific imaging probes and/or radioactive tracers, which enable efficient analysis and monitoring the therapeutic response repetitively. This chapter reviews the in vivo functional and metabolic changes after administration of Chinese herbal medicine in various neurological disorders and provides perspectives on the future evaluations of therapeutic response of Chinese herbal medicine. © 2017 Elsevier Inc. All rights reserved.

  8. Cosmogenic 22Na as a steady-state tracer of solute transport and water age in first-order catchments

    NASA Astrophysics Data System (ADS)

    Kaste, James M.; Lauer, Nancy E.; Spaetzel, Alana B.; Goydan, Claire

    2016-12-01

    Naturally-occurring cosmogenic 22Na (T1/2 = 2.6 yr) is a potentially powerful tracer of solute and water movement in catchments. However, due to its low abundance in precipitation (∼10-20 molL-1), there are only a handful of datasets documenting cosmogenic 22Na atmospheric fluxes and concentrations in surface waters. Here we present the first record of cosmogenic 22Na fallout to North America and test its use as a radiometric tracer of water age in three small catchments in the Eastern United States. We show that 22Na deposition to southeastern Virginia, USA during 2012-2014 was 187 ± 10 mBqm-2yr-1 and that flux is largely additive with precipitation amounts. Our measurements of fallout combined with previous 22Na deposition data from other regions indicate that approximately 77% of the variability in the annual global 22Na atmospheric flux is controlled by precipitation. Export of 22Na in drainage waters from three first-order forested catchments ranged from 12.5 to 174 mBq m-2 yr-1 and can be explained by a flux-based radioactive decay model, indicating that the watersheds are in steady-state with respect to cosmogenic 22Na on annual timescales. We conclude that in temperate climates with no systematic changes in rainfall amounts at the annual timescale, 22Na may be useful for quantifying the recharge age of relatively young (<20 yr) surface waters and groundwaters and for tracing solute transport at the watershed scale.

  9. Determination of irradiated reactor uranium in soil samples in Belarus using 236U as irradiated uranium tracer.

    PubMed

    Mironov, Vladislav P; Matusevich, Janna L; Kudrjashov, Vladimir P; Boulyga, Sergei F; Becker, J Sabine

    2002-12-01

    This work presents experimental results on the distribution of irradiated reactor uranium from fallout after the accident at Chernobyl Nuclear Power Plant (NPP) in comparison to natural uranium distribution in different soil types. Oxidation processes and vertical migration of irradiated uranium in soils typical of the 30 km relocation area around Chernobyl NPP were studied using 236U as the tracer for irradiated reactor uranium and inductively coupled plasma mass spectrometry as the analytical method for uranium isotope ratio measurements. Measurements of natural uranium yielded significant variations of its concentration in upper soil layers from 2 x 10(-7) g g(-1) to 3.4 x 10(-6) g g(-1). Concentrations of irradiated uranium in the upper 0-10 cm soil layers at the investigated sampling sites varied from 5 x 10(-12) g g(-1) to 2 x 10(-6) g g(-1) depending on the distance from Chernobyl NPP. In the majority of investigated soil profiles 78% to 97% of irradiated "Chernobyl" uranium is still contained in the upper 0-10 cm soil layers. The physical and chemical characteristics of the soil do not have any significant influence on processes of fuel particle destruction. Results obtained using carbonate leaching of 236U confirmed that more than 60% of irradiated "Chernobyl" uranium is still in a tetravalent form, ie. it is included in the fuel matrix (non-oxidized fuel UO2). The average value of the destruction rate of fuel particles determined for the Western radioactive trace (k = 0.030 +/- 0.005 yr(-1)) and for the Northern radioactive trace (k = 0.035 + 0.009 yr(-1)) coincide within experimental errors. Use of leaching of fission products in comparison to leaching of uranium for study of the destruction rate of fuel particles yielded poor coincidence due to the fact that use of fission products does not take into account differences in the chemical properties of fission products and fuel matrix (uranium).

  10. A novel method to quantify IRDye800CW fluorescent antibody probes ex vivo in tissue distribution studies.

    PubMed

    Oliveira, Sabrina; Cohen, Ruth; Walsum, Marijke Stigter-van; van Dongen, Guus Ams; Elias, Sjoerd G; van Diest, Paul J; Mali, Willem; van Bergen En Henegouwen, Paul Mp

    2012-09-25

    We describe a new method for biodistribution studies with IRDye800CW fluorescent antibody probes. This method allows the quantification of the IRDye800CW fluorescent tracer in percentage of injected dose per gram of tissue (% ID/g), and it is herein compared to the generally used reference method that makes use of radioactivity. Cetuximab was conjugated to both the near-infrared fluorophore IRDye800CW and/or the positron emitter 89-zirconium, which was injected in nude mice bearing A431 human tumor xenografts. Positron emission tomography (PET) and optical imaging were performed 24 h post-injection (p.i.). For the biodistribution study, organs and tumors were collected 24 h p.i., and each of these was halved. One half was used for the determination of probe uptake by radioactivity measurement. The other half was homogenized, and the content of the fluorescent probe was determined by extrapolation from a calibration curve made with the injected probe. Tumors were clearly visualized with both modalities, and the calculated tumor-to-normal tissue ratios were very similar for optical and PET imaging: 3.31 ± 1.09 and 3.15 ± 0.99, respectively. Although some variations were observed in ex vivo analyses, tumor uptake was within the same range for IRDye800CW and gamma ray quantification: 15.07 ± 3.66% ID/g and 13.92 ± 2.59% ID/g, respectively. The novel method for quantification of the optical tracer IRDye800CW gives similar results as the reference method of gamma ray quantification. This new method is considered very useful in the context of the preclinical development of IRDye800CW fluorescent probes for optical molecular imaging, likely contributing to the selection of lead compounds that are the most promising for clinical translation.

  11. Gallium-67 complexes as radioactive markers to assess gastric and colonic transit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bellen, J.C.; Chatterton, B.E.; Penglis, S.

    1995-03-01

    Constipation and gastroparesis are gastrointestinal tract disorders that can be assessed by using radioactive markers in conjunction with scintigraphic techniques. Indium-111-DTPA is the radiopharmaceutical of choice for treating colonic transit in constipated patients, but it is an expensive product and its availability has been unreliable. Indium-113m-DTPA was the tracer used in our study to determine the liquid gastric emptying rate in dual-isotope solid-liquid emptying studies, however, cessation of the {sup 113}Sn/{sup 113m}In generator production makes it unavailable. Thus, development of alternative tracers to {sup 111}In-DTPA and {sup 113m}In-DTPA was essential. Gallium-67-citrate and {sup 67}Ga-EDTA were compared to {sup 111}In-DTPA tomore » assess their efficacy for exclusive retention in the GI tract. These markers were orally administered into rats and their three-day cumulative fecal excretion, urine excretion and carcass retention were measured. An in vitro gastric emptying model was used to determine liquid phase partitioning of {sup 113m}In-DTPA, {sup 67}Ga-citrate and {sup 67}Ga-EDTA at 37{degrees}. Gallium-67-citrate was predominantly excreted in the feces (97.2% {+-} 0.2%) after three days, with negligible urine excretion (0.1% {+-} 0.0%) and carcass retention (0.6% {+-} 0.2%). These results are analogous to those obtained for {sup 111}In-DTPA for fecal excretion (96.7% {+-} 2.6%), urine excretion (0.6% {+-} 0.0%) and retention in the carcass (0.2% {+-} 0.0%). Gallium-67-EDTA showed similar partitioning in the liquid phase of the gastric emptying model compared with {sup 113m}In-DTPA. Gallium-67-citrate is an economical and readily available alternative to {sup 111}In-DTPA as a colonic transit radiopharmaceutical. Gallium-67-EDTA is also an alternative to {sup 113m}In-DTPA for assessing liquid-phase emptying in a dual-isotope solid/liquid gastric emptying study. 17 refs., 3 figs., 2 tabs.« less

  12. Geohydrologic and drill-hole data for test well USW H-4, Yucca Mountain, Nye County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitfield, M.S. Jr.; Thordarson, W.; Eshom, E.P.

    This report presents data on drilling operations, lithology, geophysical well logs, sidewall-core samples, water-level monitoring, pumping tests, injection tests, radioactive-tracer borehole flow survey, and water chemistry for test well USW H-4. The well is one of a series of test wells drilled in the southwestern part of the Nevada Test Site, Nye County, Nevada, in cooperation with the US Department of Energy. These test wells are part of the Nevada Nuclear Waste Storage Investigations to identify sites for storage of high-level radioactive wastes. Test well USW H-4 was drilled in ash-flow tuff to a total depth of 1219 meters. Depthmore » to water below land surface was 519 meters, or at an altitude of 730 meters above sea level. After test pumping at a rate of 17.4 liters per second for approximately 9 days, the drawdown was 4.85 meters. A radioactive borehole-flow survey indicated that the Bullfrog Member of the Crater Flat Tuff (Tertiary age) was the most productive geologic unit, producing 36.5 percent of the water in the well. The second most productive geologic unit was the Tram Member of the Crater Flat Tuff, which produced 32 percent of the water. The water in test well USW H-4 is predominantly a soft, sodium bicarbonate type of water typical of water produced in tuffaceous rocks in southern Nevada. 7 references, 26 figures, 9 tables.« less

  13. Water movement in the unsaturated zone at a low-level radioactive-waste burial site near Barnwell, South Carolina

    USGS Publications Warehouse

    Dennehy, Kevin F.; McMahon, Peter B.

    1989-01-01

    Four unsaturated-zone monitoring sites and a meteorologic station were installed at the low-level radioactive-waste burial site near Barnwell, S.C., to investigate the geohydrologic and climatologic factors affecting water movement in the unsaturated zone. The study site is located in the Atlantic Coastal Plain. The unsaturated zone consists of a few centimeters to more than 1 meter of surface sand, underlain by up to 15 meters of clayey sand. Two monitoring sites were installed in experimental trenches, and two were installed in radioactive-waste trenches. Two different trench designs were evaluated at the monitoring sites. A meteorologic station was used to measure precipitation and to calculate actual evapotranspiration using the Bowen ratio method. Soil-moisture tensiometers, soil-moisture conductance probes, and temperature sensors were used to monitor soil-water movement in and adjacent to the trenches. Tracer tests using sodium chloride were conducted at each monitoring site. Hydrologic properties of unsaturated-zone materials were also determined. Data collection at the monitoring sites began in January 1982 and continued until early May 1984. Tensiometer data show that the unsaturated materials had their highest percent saturations in winter and spring. Saturations in the backfill sand varied from 20 to 100 percent, and in the adjacent undisturbed and overlying compacted clayey sand, from about 75 to 100 percent. The same pattern generally was observed at all four monitoring sites. The tracer-test data indicate that water movement occurred mainly during the recharge period, winter and spring. The tracer-test results enabled computation of rates of unsaturated flow in the compacted clayey-sand cap, the compacted clayey-sand barrier, and the backfill sand. A micro-scale hydrologic budget was determined for an undisturbed part of the site from July 1983 through June 1984.Total precipitation was 144 centimeters, and actual evapotranspiration was 101 centimeters. Additionally, because tensiometer data indicate negligible water-storage changes in the unsaturated zone, it is estimated that approximately 43 centimeters of recharge reached the water table. During 1984, the rise and fall of ponded water in an experimental trench was continuously monitored with a digital recorder. This water-level record was used to compute the rate of leakage of ponded water from that trench--1 x 10 -5 centimeter per second. A cross-sectional finite-element model of variably saturated flow was used to test the conceptual model of water movement in the unsaturated zone and to illustrate the effect of trench design on water movement into the experimental trenches. Monitoring and model results show that precipitation on trenches infiltrated the trench cap and moved vertically into the trench backfill material. Precipitation on the undisturbed material adjacent to the trenches moved vertically through the surface sand and continued either downward into undisturbed clayey sand or laterally along the sand/clayey-sand interface into the backfill sand, depending on trench design. The trench construction practice of placing a compacted clayey-sand barrier around the trench greatly inhibits soil water from entering the trench.

  14. A first-in-man PET study of [18F]PSS232, a fluorinated ABP688 derivative for imaging metabotropic glutamate receptor subtype 5.

    PubMed

    Warnock, Geoffrey; Sommerauer, Michael; Mu, Linjing; Pla Gonzalez, Gloria; Geistlich, Susanne; Treyer, Valerie; Schibli, Roger; Buck, Alfred; Krämer, Stefanie D; Ametamey, Simon M

    2018-06-01

    Non-invasive imaging of metabotropic glutamate receptor 5 (mGlu 5 ) in the brain using PET is of interest in e.g., anxiety, depression, and Parkinson's disease. Widespread application of the most widely used mGlu 5 tracer, [ 11 C]ABP688, is limited by the short physical half-life of carbon-11. [ 18 F]PSS232 is a fluorinated analog with promising preclinical properties and high selectivity and specificity for mGlu 5 . In this first-in-man study, we evaluated the brain uptake pattern and kinetics of [ 18 F]PSS232 in healthy volunteers. [ 18 F]PSS232 PET was performed with ten healthy male volunteers aged 20-40 years. Seven of the subjects received a bolus injection and the remainder a bolus/infusion protocol. Cerebral blood flow was determined in seven subjects using [ 15 O]water PET. Arterial blood activity was measured using an online blood counter. Tracer kinetics were evaluated by compartment modeling and parametric maps were generated for both tracers. At 90 min post-injection, 59.2 ± 11.1% of total radioactivity in plasma corresponded to intact tracer. The regional first pass extraction fraction of [ 18 F]PSS232 ranged from 0.41 ± 0.06 to 0.55 ± 0.03 and brain distribution pattern matched that of [ 11 C]ABP688. Uptake kinetics followed a simple two-tissue compartment model. The volume of distribution of total tracer (V T , ml/cm 3 ) ranged from 1.18 ± 0.20 for white matter to 2.91 ± 0.51 for putamen. The respective mean distribution volume ratios (DVR) with cerebellum as the reference tissue were 0.88 ± 0.06 and 2.12 ± 0.10, respectively. The tissue/cerebellum ratios of a bolus/infusion protocol (30/70 dose ratio) were close to the DVR values. Brain uptake of [ 18 F]PSS232 matched the distribution of mGlu 5 and followed a two-tissue compartment model. The well-defined kinetics and the possibility to use reference tissue models, obviating the need for arterial blood sampling, make [ 18 F]PSS232 a promising fluorine-18 labeled radioligand for measuring mGlu 5 density in humans.

  15. ⁸⁹Zr-Labeled Versus ¹²⁴I-Labeled αHER2 Fab with Optimized Plasma Half-Life for High-Contrast Tumor Imaging In Vivo.

    PubMed

    Mendler, Claudia T; Gehring, Torben; Wester, Hans-Jürgen; Schwaiger, Markus; Skerra, Arne

    2015-07-01

    Immuno-PET imaging of the tumor antigen HER2/neu allows for the noninvasive detection and monitoring of oncogene expression; such detection and monitoring are of prognostic value in patients with breast cancer. Compared with the full-size antibody trastuzumab, smaller protein tracers with more rapid blood clearance permit higher imaging contrast at earlier time points. Antigen-binding fragments (Fabs) of antibodies with moderately prolonged circulation achieved through the genetic fusion with a long, conformationally disordered chain of the natural amino acids Pro, Ala, and Ser (PASylation)-a biologic alternative to chemical conjugation with polyethylene glycol, PEG-offer a promising tracer format with improved pharmacokinetics for in vivo imaging. Recently, the transition metal radionuclide (89)Zr has attracted increasing interest for immuno-PET studies, complementing the conventional halogen radionuclide (124)I. To allow direct comparison of these 2 radioactive labels for the same protein tracer, the recombinant αHER2 Fab fused with 200 Pro, Ala, and Ser (PAS200) residues was either conjugated with (124)I via an iodination reagent or coupled with deferoxamine (Df) and complexed with (89)Zr. After confirmation of the stability of both radioconjugates and quality control in vitro, immuno-PET and biodistribution studies were performed with CD1-Foxn1(nu) mice bearing HER2-positive human tumor xenografts. (89)Zr⋅Df-Fab-PAS200 and (124)I-Fab-PAS200 showed specific tumor uptake of 11 and 2.3 percentage injected dose per gram 24 h after injection, respectively; both led to high tumor-to-blood (3.6 and 4.4, respectively) and tumor-to-muscle (20 and 43, respectively) ratios. With regard to off-target accumulation, overt (124)I activity was seen in the thyroid, as expected, whereas high kidney uptake was evident for (89)Zr; the latter was probably due to glomerular filtration and reabsorption of the protein tracer in proximal tubular cells. Both (89)Zr- and (124)I-labeled versions of αHER2 Fab-PAS200 allowed PET tumor imaging with high contrast. With its residualizing radiometal, the tracer (89)Zr⋅Df-Fab-PAS200 showed better in vivo stability and higher tumor uptake. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  16. A radioisotope based methodology for plant-fungal interactions in the rhizosphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weisenberger, A. G.; Bonito, G.; Lee, S.

    In plant ecophysiology research there is interest in studying the biology of the rhizosphere because of its importance in plant nutrient-interactions. The rhizosphere is the zone of soil surrounding a plant's root system where microbes (such as fungi) are influenced by the root and the roots by the microbes. We are investigating a methodology for imaging the distribution of molecular compounds of interest in the rhizosphere without disturbing the root or soil habitat. Our intention is to develop a single photon emission computed tomography (SPECT) system (PhytoSPECT) to image the bio-distribution of fungi in association with a host plant's roots.more » The technique we are exploring makes use of radioactive isotopes as tracers to label molecules that bind to fungal-specific compounds of interest and to image the fungi distribution in the plant and/or soil. We report on initial experiments designed to test the ability of fungal-specific compounds labeled with an iodine radioisotope that binds to chitin monomers (N-acetylglucosamine). Chitin is a compound not found in roots but in fungal cell walls. We will test the ability to label the compound with radioactive isotopes of iodine ({sup 125}I, and {sup 123}I).« less

  17. Copper crystal lens for medical imaging: first results

    NASA Astrophysics Data System (ADS)

    Roa, Dante E.; Smither, Robert K.

    2001-06-01

    A copper crystal lens designed to focus gamma ray energies of 100 to 200 keV has been assembled at Argonne National Laboratory. In particular, the lens has been optimized to focus the 140.6 keV gamma rays from technetium-99 m typically used in radioactive tracers. This new approach to medical imaging relies on crystal diffraction to focus incoming gamma rays in a manner similar to a simple convex lens focusing visible light. The lens is envisioned to be part of an array of lenses that can be used as a complementary technique to gamma cameras for localized scans of suspected tumor regions in the body. In addition, a 2- lens array can be used to scan a woman's breast in search of tumors with no discomfort to the patient. The incoming gamma rays are diffracted by a set of 828 copper crystal cubes arranged in 13 concentric rings, which focus the gamma rays into a very small area on a well-shielded NaI detector. Experiments performance with technetium-99 m and cobalt 57 radioactive sources indicate that a 6-lens array should be capable of detecting sources with (mu) Ci strength.

  18. Reaeration capacity of the Rock River between Lake Koshkonong, Wisconsin and Rockton, Illinois

    USGS Publications Warehouse

    Grant, R. Stephen

    1978-01-01

    The reaeration capacity of the Rock River from Lake Koshkonong, Wisconsin, to Rockton, Illinois, was determined using the energy-dissipation model. The model was calibrated using data from radioactive-tracer measurements in the study reach. Reaeration coefficients (K2) were computed for the annual minimum 7-day mean discharge that occurs on the average of once in 10 years (Q7,10). A time-of-travel model was developed using river discharge, slope, and velocity data from three dye studies. The model was used to estimate traveltime for the Q7,10 for use in the energy-dissipation model. During one radiotracer study, 17 mile per hour winds apparently increased the reaeration coefficient about 40 times. (Woodard-USGS)

  19. Methods for determination of optic nerve blood flow.

    PubMed Central

    Glazer, L. C.

    1988-01-01

    A variety of studies have been conducted over the past two decades to determine if decreased optic nerve blood flow has a role in the etiology of glaucomatous nerve damage. Five basic methods have been employed in examining blood flow. Invasive studies, utilizing electrodes placed in the optic nerve head, represent one of the first attempts to measure blood flow. More recently, the methodologies have included axoplasmic flow analysis, microspheres, radioactive tracers such as iodoantipyrine, and laser doppler measurements. The results of these studies are inconclusive and frequently contradictory. When the studies are grouped by methodology, only the iodoantipyrine data are consistent. While each of the experimental techniques has limitations, iodoantipyrine appears to have better resolution than either invasive studies or microspheres. PMID:3284212

  20. Nuclear medicine and imaging research (Instrumentation and quantitative methods of evaluation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beck, R.N.; Cooper, M.D.

    1989-09-01

    This program addresses the problems involving the basic science and technology underlying the physical and conceptual tools of radioactive tracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The overall objective of this program is to further the development and transfer of radiotracer methodology from basic theory to routine clinical practice in order that individual patients and society as a whole will receive the maximum net benefit from the new knowledge gained. The focus of the research is on the development ofmore » new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility.« less

  1. Chlorine-36 in the Snake River Plain Aquifer at the Idaho National Engineering Laboratory; origin and implications

    USGS Publications Warehouse

    Beasley, T.M.; Cecil, L.D.; Sharma, P.; Kubik, P.W.; Fehn, U.; Mann, L.J.; Gove, H.E.

    1993-01-01

    Between 1952 and 1984, low-level radioactive waste was introduced directly into the Snake River Plain aquifer at the Idaho National Engineering Laboratory (INEL), Idaho Falls, Idaho. These wastes were generated, principally, at the nuclear fuel reprocessing facility on the site. Our measurements of 36C1 in monitoring and production well waters, downgradient from disposal wells and seepage ponds, found easily detectable, nonhazardous concentrations of this radionuclide from the point of injection to the INEL southern site boundary. Comparisons are made between 3H and 36Cl concentrations in aquifer water and the advantages of 36C1 as a tracer of subsurface-water dynamics at the site are discussed.

  2. Determination of steady state and nonsteady-state glycerol kinetics in humans using deuterium-labeled tracer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beylot, M.; Martin, C.; Beaufrere, B.

    1987-04-01

    Using deuterium-labeled glycerol as tracer and gas-liquid chromatography-mass spectrometry techniques for the determination of isotopic enrichment, we have developed a simple and ethically acceptable method of determining glycerol appearance rate in humans under steady-state and nonsteady-state conditions. In normal subjects, the appearance rate of glycerol in the post-absorptive state was 2.22 +/- 0.20 mumol X kg-1 X min-1, a value in agreement with those reported in studies with radioactively labeled tracers. The ratio nonesterified fatty acid (NEFA) appearance rate/glycerol appearance rate ranged from 1.95 to 3.40. In insulin-dependent diabetic patients with a mild degree of metabolic control, the appearance ratemore » of glycerol was 2.48 +/- 0.29 mumol X kg-1 X min-1. The volume of distribution of glycerol, determined by the bolus injection technique, was (mean) 0.306 l X kg-1 in normal subjects and 0.308 l X kg-1 in insulin-independent diabetic patients. To evaluate the usefulness of the method for determination of glycerol kinetics in nonsteady-state conditions, we infused six normal subjects with natural glycerol and calculated the isotopically determined glycerol appearance rate using a single compartment model (volume of distribution 0.31 l X kg-1). During these tests, the expected glycerol appearance rates were successively 5.03 +/- 0.33, 7.48 +/- 0.39, 9.94 +/- 0.34, 7.48 +/- 0.39, and 5.03 +/- 0.33 mumol +/- kg-1 X min-1, whereas the corresponding isotopically determined appearance rates were 4.62 +/- 0.45, 6.95 +/- 0.56, 10.85 +/- 0.51, 7.35 +/- 0.34, and 5.28 +/- 0.12 mumol X kg-1 X min-1.« less

  3. Imaging and modeling of flow in porous media using clinical nuclear emission tomography systems and computational fluid dynamics

    NASA Astrophysics Data System (ADS)

    Boutchko, Rostyslav; Rayz, Vitaliy L.; Vandehey, Nicholas T.; O'Neil, James P.; Budinger, Thomas F.; Nico, Peter S.; Druhan, Jennifer L.; Saloner, David A.; Gullberg, Grant T.; Moses, William W.

    2012-01-01

    This paper presents experimental and modeling aspects of applying nuclear emission tomography to study fluid flow in laboratory packed porous media columns of the type frequently used in geophysics, geochemistry and hydrology research. Positron emission tomography (PET) and single photon emission computed tomography (SPECT) are used as non-invasive tools to obtain dynamic 3D images of radioactive tracer concentrations. Dynamic sequences obtained using 18F-FDG PET are used to trace flow through a 5 cm diameter × 20 cm tall sand packed column with and without an impermeable obstacle. In addition, a custom-made rotating column setup placed in a clinical two-headed SPECT camera is used to image 99mTc-DTPA tracer propagation in a through-flowing column (10 cm diameter × 30 cm tall) packed with recovered aquifer sediments. A computational fluid dynamics software package FLUENT is used to model the observed flow dynamics. Tracer distributions obtained in the simulations in the smaller column uniformly packed with sand and in the column with an obstacle are remarkably similar to the reconstructed images in the PET experiments. SPECT results demonstrate strongly non-uniform flow patterns for the larger column slurry-packed with sub-surface sediment and slow upward flow. In the numerical simulation of the SPECT study, two symmetric channels with increased permeability are prescribed along the column walls, which result in the emergence of two well-defined preferential flow paths. Methods and results of this work provide new opportunities in hydrologic and biogeochemical research. The primary target application for developed technologies is non-destructive, non-perturbing, quantitative imaging of flow dynamics within laboratory scale porous media systems.

  4. Imaging and modeling of flow in porous media using clinical nuclear emission tomography systems and computational fluid dynamics.

    PubMed

    Boutchko, Rostyslav; Rayz, Vitaliy L; Vandehey, Nicholas T; O'Neil, James P; Budinger, Thomas F; Nico, Peter S; Druhan, Jennifer L; Saloner, David A; Gullberg, Grant T; Moses, William W

    2012-01-01

    This paper presents experimental and modeling aspects of applying nuclear emission tomography to study fluid flow in laboratory packed porous media columns of the type frequently used in geophysics, geochemistry and hydrology research. Positron emission tomography (PET) and single photon emission computed tomography (SPECT) are used as non-invasive tools to obtain dynamic 3D images of radioactive tracer concentrations. Dynamic sequences obtained using 18 F-FDG PET are used to trace flow through a 5 cm diameter × 20 cm tall sand packed column with and without an impermeable obstacle. In addition, a custom-made rotating column setup placed in a clinical two-headed SPECT camera is used to image 99m Tc-DTPA tracer propagation in a through-flowing column (10 cm diameter × 30 cm tall) packed with recovered aquifer sediments. A computational fluid dynamics software package FLUENT is used to model the observed flow dynamics. Tracer distributions obtained in the simulations in the smaller column uniformly packed with sand and in the column with an obstacle are remarkably similar to the reconstructed images in the PET experiments. SPECT results demonstrate strongly non-uniform flow patterns for the larger column slurry-packed with sub-surface sediment and slow upward flow. In the numerical simulation of the SPECT study, two symmetric channels with increased permeability are prescribed along the column walls, which result in the emergence of two well-defined preferential flow paths. Methods and results of this work provide new opportunities in hydrologic and biogeochemical research. The primary target application for developed technologies is non-destructive, non-perturbing, quantitative imaging of flow dynamics within laboratory scale porous media systems.

  5. In vivo assessment of cardiac insulin resistance by nuclear probes using an iodinated tracer of glucose transport.

    PubMed

    Briat, Arnaud; Slimani, Lotfi; Perret, Pascale; Villemain, Danièle; Halimi, Serge; Demongeot, Jacques; Fagret, Daniel; Ghezzi, Catherine

    2007-11-01

    Insulin resistance, implying depressed cellular sensitivity to insulin, is a risk factor for type 2 diabetes and cardiovascular disease. This study is the first step towards the development of a technique of insulin resistance measurement in humans with a new tracer of glucose transport, [(123)I]6-deoxy-6-iodo-D-glucose (6DIG). We investigated 6DIG kinetics in anaesthetised control rats and in three models of insulin-resistant rats: fructose fed, Zucker and ZDF. The study of myocardial 6DIG activity was performed under two conditions: first, 6DIG was injected under the baseline condition and then it was injected after a bolus injection of insulin. After each injection, radioactivity was measured over 45 min by external detection via NaI probes, in the heart and blood. A tri-compartment model was developed to obtain fractional transfer coefficients of 6DIG from the blood to the heart. These coefficients were significantly increased with insulin in control rats and did not change significantly in insulin-resistant rats. The ratio of the coefficient obtained under insulin to that obtained under basal conditions gave an index of cardiac insulin resistance for each animal. The mean values of these ratios were significantly lower in insulin-resistant than in control rats: 1.16 +/- 0.06 vs 2.28 +/- 0.18 (p < 0.001) for the fructose-fed group, 0.92 +/- 0.05 vs 1.62 +/- 0.25 (p < 0.01) for the Zucker group and 1.34 +/- 0.06 vs 2.01 +/- 0.26 (p < 0.05) for the ZDF group. These results show that 6DIG could be a useful tracer to image cardiac insulin resistance.

  6. Toward optimization of imaging system and lymphatic tracer for near-infrared fluorescent sentinel lymph node mapping in breast cancer.

    PubMed

    Mieog, J Sven D; Troyan, Susan L; Hutteman, Merlijn; Donohoe, Kevin J; van der Vorst, Joost R; Stockdale, Alan; Liefers, Gerrit-Jan; Choi, Hak Soo; Gibbs-Strauss, Summer L; Putter, Hein; Gioux, Sylvain; Kuppen, Peter J K; Ashitate, Yoshitomo; Löwik, Clemens W G M; Smit, Vincent T H B M; Oketokoun, Rafiou; Ngo, Long H; van de Velde, Cornelis J H; Frangioni, John V; Vahrmeijer, Alexander L

    2011-09-01

    Near-infrared (NIR) fluorescent sentinel lymph node (SLN) mapping in breast cancer requires optimized imaging systems and lymphatic tracers. A small, portable version of the FLARE imaging system, termed Mini-FLARE, was developed for capturing color video and two semi-independent channels of NIR fluorescence (700 and 800 nm) in real time. Initial optimization of lymphatic tracer dose was performed using 35-kg Yorkshire pigs and a 6-patient pilot clinical trial. More refined optimization was performed in 24 consecutive breast cancer patients. All patients received the standard of care using (99m)Technetium-nanocolloid and patent blue. In addition, 1.6 ml of indocyanine green adsorbed to human serum albumin (ICG:HSA) was injected directly after patent blue at the same location. Patients were allocated to 1 of 8 escalating ICG:HSA concentration groups from 50 to 1000 μM. The Mini-FLARE system was positioned easily in the operating room and could be used up to 13 in. from the patient. Mini-FLARE enabled visualization of lymphatic channels and SLNs in all patients. A total of 35 SLNs (mean = 1.45, range 1-3) were detected: 35 radioactive (100%), 30 blue (86%), and 35 NIR fluorescent (100%). Contrast agent quenching at the injection site and dilution within lymphatic channels were major contributors to signal strength of the SLN. Optimal injection dose of ICG:HSA ranged between 400 and 800 μM. No adverse reactions were observed. We describe the clinical translation of a new NIR fluorescence imaging system and define the optimal ICG:HSA dose range for SLN mapping in breast cancer.

  7. Tritium as tracer of groundwater pollution extension: case study of Andralanitra landfill site, Antananarivo-Madagascar

    NASA Astrophysics Data System (ADS)

    Ramaroson, Voahirana; Rakotomalala, Christian Ulrich; Rajaobelison, Joel; Fareze, Lahimamy Paul; Razafitsalama, Falintsoa A.; Rasolofonirina, Mamiseheno

    2018-05-01

    This study aims to understand the extension of groundwater pollution downstream of a landfill, Andralanitra-Antananarivo-Madagascar. Twenty-one samples, composed of dug well waters, spring waters, river, and lake, were measured in stable isotopes ( δ 2H, δ 18O) and tritium. Results showed that only two dug well waters, collected at the immediate vicinity of the landfill, have high tritium activities (22.82 TU and 10.43 TU), probably of artificial origin. Both upstream and further downstream of the landfill, tritium activities represent natural source, with values varying from 0.17 TU to 1.46 TU upstream and from 0.88 TU to 1.88 TU further downstream. Stable isotope data suggest that recharge occurs through infiltration of slightly evaporated rainfall. Using the radioactive decay equation, the calculated tracer ages related to two recent ground water samples collected down gradient of the landfill lay between [8-15] years and [4-7] years, taking into account the uncertainty of tritium measurements. For the calculation, a value of 2.36 TU was taken as A o. The latter was estimated based on similarity between stable isotope compositions of nearby spring and dug well waters as well as tritium activities of the local precipitation. Calculation of the tritium activities from the contaminated water point having 22.82 TU to further downstream using the calculated tracer ages showed values of one order of magnitude higher than the measured values. The absence of hydrological connection from the contaminated water point to further downstream the landfill would explain the lower tritium activities measured. Groundwater pollution seems to be limited to the closest proximity of the landfill.

  8. Radiosynthesis and in Vivo Evaluation of [11C]A1070722, a High Affinity GSK-3 PET Tracer in Primate Brain.

    PubMed

    Prabhakaran, Jaya; Zanderigo, Francesca; Sai, Kiran Kumar Solingapuram; Rubin-Falcone, Harry; Jorgensen, Matthew J; Kaplan, Jay R; Mintz, Akiva; Mann, J John; Kumar, J S Dileep

    2017-08-16

    Dysfunction of glycogen synthase kinase 3 (GSK-3) is implicated in the etiology of Alzheimer's disease, Parkinson's disease, diabetes, pain, and cancer. A radiotracer for functional positron emission tomography (PET) imaging could be used to study the kinase in brain disorders and to facilitate the development of small molecule inhibitors of GSK-3 for treatment. At present, there is no target-specific or validated PET tracer available for the in vivo monitoring of GSK-3. We radiolabeled the small molecule inhibitor [ 11 C]1-(7-methoxy- quinolin-4-yl)-3-(6-(trifluoromethyl)pyridin-2-yl)urea ([ 11 C]A1070722) with high affinity to GSK-3 (K i = 0.6 nM) in excellent radiochemical yield. PET imaging experiments in anesthetized vervet/African green monkey exhibited that [ 11 C]A1070722 penetrated the blood-brain barrier (BBB) and accumulated in brain regions, with highest radioactivity binding in frontal cortex followed by parietal cortex and anterior cingulate, and with the lowest bindings found in caudate, putamen, and thalamus, similarly to the known distribution of GSK-3 in human brain. Our studies suggest that [ 11 C]A1070722 can be a potential PET radiotracer for the in vivo quantification of GSK-3 in brain.

  9. Chylomicron metabolism in rats: kinetic modeling indicates that the particles remain at endothelial sites for minutes[S

    PubMed Central

    Hultin, Magnus; Savonen, Roger; Chevreuil, Olivier; Olivecrona, Thomas

    2013-01-01

    Chylomicrons labeled in vivo with 14C-oleic acid (primarily in triglycerides, providing a tracer for lipolysis) and 3H-retinol (primarily in ester form, providing a tracer for the core lipids) were injected into rats. Radioactivity in tissues was followed at a series of times up to 40 min and the data were analyzed by compartmental modeling. For heart-like tissues it was necessary to allow the chylomicrons to enter into a compartment where lipolysis is rapid and then transfer to a second compartment where lipolysis is slower. The particles remained in these compartments for minutes and when they returned to blood they had reduced affinity for binding in the tissue. In contrast, the data for liver could readily be fitted with a single compartment for native and lipolyzed chylomicrons in blood, and there was no need for a pathway back to blood. A composite model was built from the individual tissue models. This whole-body model could simultaneously fit all data for both fed and fasted rats and allowed estimation of fluxes and residence times in the four compartments; native and lipolyzed chylomicrons (“remnants”) in blood, and particles in the tissue compartments where lipolysis is rapid and slow, respectively. PMID:23922383

  10. Spectral Analysis of Dynamic PET Studies: A Review of 20 Years of Method Developments and Applications.

    PubMed

    Veronese, Mattia; Rizzo, Gaia; Bertoldo, Alessandra; Turkheimer, Federico E

    2016-01-01

    In Positron Emission Tomography (PET), spectral analysis (SA) allows the quantification of dynamic data by relating the radioactivity measured by the scanner in time to the underlying physiological processes of the system under investigation. Among the different approaches for the quantification of PET data, SA is based on the linear solution of the Laplace transform inversion whereas the measured arterial and tissue time-activity curves of a radiotracer are used to calculate the input response function of the tissue. In the recent years SA has been used with a large number of PET tracers in brain and nonbrain applications, demonstrating that it is a very flexible and robust method for PET data analysis. Differently from the most common PET quantification approaches that adopt standard nonlinear estimation of compartmental models or some linear simplifications, SA can be applied without defining any specific model configuration and has demonstrated very good sensitivity to the underlying kinetics. This characteristic makes it useful as an investigative tool especially for the analysis of novel PET tracers. The purpose of this work is to offer an overview of SA, to discuss advantages and limitations of the methodology, and to inform about its applications in the PET field.

  11. Tracing Fasting Glucose Fluxes with Unstressed Catheter Approach in Streptozotocin Induced Diabetic Rats

    PubMed Central

    Wu, Hui; Xu, Xiao; Meng, Ying; Xia, Fangzhen; Zhai, Hualing; Lu, Yingli

    2014-01-01

    Objective. Blood glucose concentrations of type 1 diabetic rats are vulnerable, especially to stress and trauma. The present study aimed to investigate the fasting endogenous glucose production and skeletal muscle glucose uptake of Streptozotocin induced type 1 diabetic rats using an unstressed vein and artery implantation of catheters at the tails of the rats as a platform. Research Design and Methods. Streptozotocin (65 mg·kg−1) was administered to induce type 1 diabetic state. The unstressed approach of catheters of vein and artery at the tails of the rats was established before the isotope tracer injection. Dynamic measurement of fasting endogenous glucose production was assessed by continuously infusing stable isotope [6, 6-2H2] glucose, while skeletal muscle glucose uptake by bolus injecting radioactively labeled [1-14C]-2-deoxy-glucose. Results. Streptozotocin induced type 1 diabetic rats displayed polydipsia, polyphagia, and polyuria along with overt hyperglycemia and hypoinsulinemia. They also had enhanced fasting endogenous glucose production and reduced glucose uptake in skeletal muscle compared to nondiabetic rats. Conclusions. The dual catheters implantation at the tails of the rats together with isotope tracers injection is a save time, unstressed, and feasible approach to explore the glucose metabolism in animal models in vivo. PMID:24772449

  12. Molecular imaging and therapy targeting copper metabolism in hepatocellular carcinoma

    PubMed Central

    Wachsmann, Jason; Peng, Fangyu

    2016-01-01

    Hepatocellular carcinoma (HCC) is the fifth most common cancer worldwide. Significant efforts have been devoted to identify new biomarkers for molecular imaging and targeted therapy of HCC. Copper is a nutritional metal required for the function of numerous enzymatic molecules in the metabolic pathways of human cells. Emerging evidence suggests that copper plays a role in cell proliferation and angiogenesis. Increased accumulation of copper ions was detected in tissue samples of HCC and many other cancers in humans. Altered copper metabolism is a new biomarker for molecular cancer imaging with position emission tomography (PET) using radioactive copper as a tracer. It has been reported that extrahepatic mouse hepatoma or HCC xenografts can be localized with PET using copper-64 chloride as a tracer, suggesting that copper metabolism is a new biomarker for the detection of HCC metastasis in areas of low physiological copper uptake. In addition to copper modulation therapy with copper chelators, short-interference RNA specific for human copper transporter 1 (hCtr1) may be used to suppress growth of HCC by blocking increased copper uptake mediated by hCtr1. Furthermore, altered copper metabolism is a promising target for radionuclide therapy of HCC using therapeutic copper radionuclides. Copper metabolism has potential as a new theranostic biomarker for molecular imaging as well as targeted therapy of HCC. PMID:26755872

  13. Reactive transport modelling of a high-pH infiltration test in concrete

    NASA Astrophysics Data System (ADS)

    Chaparro, M. Carme; Soler, Josep M.; Saaltink, Maarten W.; Mäder, Urs K.

    2017-06-01

    A laboratory-scale tracer test was carried out to characterize the transport properties of concrete from the Radioactive Waste Disposal Facility at El Cabril (Spain). A hyperalkaline solution (K-Ca-OH, pH = 13.2) was injected into a concrete sample under a high entry pressure in order to perform the experiment within a reasonable time span, obtaining a decrease of permeability by a factor of 1000. The concentrations of the tracers, major elements (Ca2+, SO4 2 - , K+ and Na+) and pH were measured at the outlet of the concrete sample. A reactive transport model was built based on a double porosity conceptual model, which considers diffusion between a mobile zone, where water can flow, and an immobile zone without any advective transport. The numerical model assumed that all reactions took place in the immobile zone. The cement paste consists of C-S-H gel, portlandite, ettringite, calcite and gypsum, together with residual alite and belite. Two different models were compared, one with portlandite in equilibrium (high initial surface area) and another one with portlandite reaction controlled by kinetics (low initial surface area). Overall the results show dissolution of alite, belite, gypsum, quartz, C-S-H gel and ettringite and precipitation of portlandite and calcite. Permeability could have decreased due to mineral precipitation.

  14. Assessment of the LV-C2 Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.

    2015-09-01

    This document reports on a series of tests conducted to assess the proposed air sampling location for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) C2V (LV-C2) exhaust stack with respect to the applicable criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probemore » to extract a sample that represents the effluent stream. The tests were conducted on the LV-C2 scale model system. Based on the scale model tests, the location proposed for the air sampling probe in the scale model stack meets the requirements of the ANSI/HPS N13.1-1999 standard for velocity uniformity, flow angle, gas tracer and particle tracer uniformity. Additional velocity uniformity and flow angle tests on the actual stack will be necessary during cold startup to confirm the validity of the scale model results in representing the actual stack.« less

  15. Hybrid Imaging Labels: Providing the Link Between Mass Spectrometry-Based Molecular Pathology and Theranostics

    PubMed Central

    Buckle, Tessa; van der Wal, Steffen; van Malderen, Stijn J.M.; Müller, Larissa; Kuil, Joeri; van Unen, Vincent; Peters, Ruud J.B.; van Bemmel, Margaretha E.M.; McDonnell, Liam A.; Velders, Aldrik H.; Koning, Frits; Vanhaeke, Frank; van Leeuwen, Fijs W. B.

    2017-01-01

    Background: Development of theranostic concepts that include inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) imaging can be hindered by the lack of a direct comparison to more standardly used methods for in vitro and in vivo evaluation; e.g. fluorescence or nuclear medicine. In this study a bimodal (or rather, hybrid) tracer that contains both a fluorescent dye and a chelate was used to evaluate the existence of a direct link between mass spectrometry (MS) and in vitro and in vivo molecular imaging findings using fluorescence and radioisotopes. At the same time, the hybrid label was used to determine whether the use of a single isotope label would allow for MS-based diagnostics. Methods: A hybrid label that contained both a DTPA chelate (that was coordinated with either 165Ho or 111In) and a Cy5 fluorescent dye was coupled to the chemokine receptor 4 (CXCR4) targeting peptide Ac-TZ14011 (hybrid-Cy5-Ac-TZ4011). This receptor targeting tracer was used to 1) validate the efficacy of (165Ho-based) mass-cytometry in determining the receptor affinity via comparison with fluorescence-based flow cytometry (Cy5), 2) evaluate the microscopic binding pattern of the tracer in tumor cells using both fluorescence confocal imaging (Cy5) and LA-ICP-MS-imaging (165Ho), 3) compare in vivo biodistribution patterns obtained with ICP-MS (165Ho) and radiodetection (111In) after intravenous administration of hybrid-Cy5-Ac-TZ4011 in tumor-bearing mice. Finally, LA-ICP-MS-imaging (165Ho) was linked to fluorescence-based analysis of excised tissue samples (Cy5). Results: Analysis with both mass-cytometry and flow cytometry revealed a similar receptor affinity, respectively 352 ± 141 nM and 245 ± 65 nM (p = 0.08), but with a much lower detection sensitivity for the first modality. In vitro LA-ICP-MS imaging (165Ho) enabled clear discrimination between CXCR4 positive and negative cells, but fluorescence microscopy was required to determine the intracellular distribution. In vivo biodistribution patterns obtained with ICP-MS (165Ho) and radiodetection (111In) of the hybrid peptide were shown to be similar. Assessment of tracer distribution in excised tissues revealed the location of tracer uptake with both LA-ICP-MS-imaging and fluorescence imaging. Conclusion: Lanthanide-isotope chelation expands the scope of fluorescent/radioactive hybrid tracers to include MS-based analytical tools such as mass-cytometry, ICP-MS and LA-ICP-MS imaging in molecular pathology. In contradiction to common expectations, MS detection using a single chelate imaging agent was shown to be feasible, enabling a direct link between nuclear medicine-based imaging and theranostic methods. PMID:28255355

  16. Simplifications in analyzing positron emission tomography data: effects on outcome measures.

    PubMed

    Logan, Jean; Alexoff, David; Kriplani, Aarti

    2007-10-01

    Initial validation studies of new radiotracers generally involve kinetic models that require a measured arterial input function. This allows for the separation of tissue binding from delivery and blood flow effects. However, when using a tracer in a clinical setting, it is necessary to eliminate arterial blood sampling due to its invasiveness and the extra burden of counting and analyzing the blood samples for metabolites. In some cases, it may also be necessary to replace dynamic scanning with a shortened scanning period some time after tracer injection, as is done with FDG (F-18 fluorodeoxyglucose). These approximations represent loss of information. In this work, we considered several questions related to this: (1) Do differences in experimental conditions (drug treatments) or populations affect the input function, and what effect, if any, does this have on the final outcome measure? (2) How do errors in metabolite measurements enter into results? (3) What errors are incurred if the uptake ratio is used in place of the distribution volume ratio? (4) Is one- or two-point blood sampling any better for FDG data than the standardized uptake value? and (5) If blood sampling is necessary, what alternatives are there to arterial blood sampling? The first three questions were considered in terms of data from human dynamic positron emission tomography (PET) studies under conditions of baseline and drug pretreatment. Data from [11C]raclopride studies and those from the norepinephrine transporter tracer (S,S)-[11C]O-methyl reboxetine were used. Calculation of a metabolic rate for FDG using the operational equation requires a measured input function. We tested a procedure based on two blood samples to estimate the plasma integral and convolution that occur in the operational equation. There are some tracers for which blood sampling is necessary. Strategies for brain studies involve using the internal carotids in estimating the radioactivity after correcting for partial volume and spillover in order to eliminate arterial sampling. Some venous blood samples are still required for metabolite measurements. The ultimate solution to the problem of arterial sampling may be a wrist scanner, which acts as a small PET camera for imaging the arteries in the wrist. This is currently under development.

  17. Characterization of Preferential Flow Path in Fractured Rock Using Heat-pulse Flowmeter

    NASA Astrophysics Data System (ADS)

    Lee, Tsai-Ping; Lin, Ming-Hsuan; Chuang, Po-Yu; Chia, Yeeping

    2015-04-01

    Rigorous thinking on how to dispose radioactive wastes safely is essential to mankind and living environment. The concepts of multiple barriers and deep geologic disposal remain the preferred option to retard the radionuclide migration in most countries. However, the investigation of preferential groundwater flow path in a fractured rock is a challenge to the characterization of potential disposal site. Heat-pulse flowmeter is a developing logging tool for measuring the vertical flow velocity in a borehole under a constant pumping or injection rate and provides a promising direct measurement method for determining the vertical distribution of hydraulic conductivity of formation. As heat-pulse flowmeter is a potential technique to measure low-velocity borehole flow, we adopted it to test the feasibility of detecting permeable fractures. Besides, a new magnetic tracer made by nano-iron particles is developed to identify the possible flow path precisely and to verify the permeable section detected by the heat-pulse flowmeter. The magnetic tracer was received by a magnet array and can also be detected by a sensor of electric conductivity. The test site is located in the Heshe of Taiwan. Eight wells were established in a fractured sandy siltstone for characterizing the fracture network. The test wells are 25 to 45 m depth and opened ranging from 15 to 45 m. Prior to the heat-pulse flowmeter measurement, we also performed surface geological investigation, pumping test, geophysical logging, and salt tracer test. Field measurements using heat-pulse flowmeter were then conducted at a constant pumping rate. The measurement interval is 50 to 100 cm in depth but improved to 25 cm near the relatively permeable zone. Based on the results of heat-pulse flowmeter, several permeable sections were identified. The magnetic tracer tests were then conducted to verify the potential preferential flow pathway between adjacent wells. Test results indicated that water flow in borehole is produced primarily from a few fractures. However, the large aperture and high density of fractures did not certainly correlate well to the permeable section. Integration of heat-pulse flowmeter measurement with other in-situ tests, it is possible to identify the exact location of the highly permeable fractures.

  18. Retention of 125I-labeled recombinant human bone morphogenetic protein-2 by biphasic calcium phosphate or a composite sponge in a rabbit posterolateral spine arthrodesis model.

    PubMed

    Louis-Ugbo, John; Kim, Hak-Sun; Boden, Scott D; Mayr, Matthew T; Li, Ronald C; Seeherman, Howard; D'Augusta, Darren; Blake, Cara; Jiao, Aiping; Peckham, Steve

    2002-09-01

    The purpose of this study was to characterize the retention kinetics of recombinant human bone morphogenetic protein-2 (rhBMP-2) applied to two calcium-based delivery matrices. Biphasic calcium phosphate (BCP) and a composite containing BCP in an absorbable collagen sponge (BCP/ACS) were evaluated using a spinal fusion model in rabbits. rhBMP-2 labeled with radioactive iodine (125I) was used as a tracer to assess in vivo retention of rhBMP-2 in the presence of these materials (nine animals per material studied). Over a 36 day study period, animals were assessed for the following: percent administered dose retained at the implant site as measured by scintigraphic imaging (counting) with a gamma camera (all animals), radiography of the implant site (all animals), radioactivity in blood and plasma (all animals), and radioactivity in the urine and feces (three animals for each material). Radioactivity data were corrected for the decay of 125I and the attenuation between the implant in vivo and the gamma camera. Differences observed between the two materials for the area under the retention vs. time profile (AUC; 988%*day for BCP vs. 1070%*day for BCP/ACS, p = 0.57) and the mean residence time (MRT; 10.2 days for BCP vs. 7.6 days for BCP/ACS, p = 0.06) were not statistically significant. Initial retention/incorporation of rhBMP-2 was slightly higher for rhBMP-2/BCP/ACS than for rhBMP-2/BCP (96.8% vs. 86.0%, p < 0.05). Animals receiving rhBMP-2/BCP showed a longer terminal retention half-life (t1/2) than did those receiving rhBMP-2/BCP/ACS (7.5 vs. 4.5 days, p < 0.05). The urinary radioactivity recovery data supported the data obtained by scintigraphy. Over the 36 day collection period, essentially complete recovery of radioactivity (dose) in urine was observed for rhBMP-2/BCP and rhBMP-2/BCP/ACS and the majority of the radioactivity (approximately 95%) was soluble in trichloroacetic acid, suggesting extensive catabolism of rhBMP-2 before renal excretion. Fecal recovery of radioactivity was low, approximately 2-3%. In conclusion, rhBMP-2 was retained at the implant site when delivered with either BCP or BCP/ACS based on mean residence time and area under the retention curve vs. time profile. Use of these matrices resulted in detectable rhBMP-2 levels at the surgical site for over a week in contrast to data reported with several other matrices that lasted less time. Systemic catabolism and elimination of the rhBMP-2 was extensive and systemic presence of the protein was negligible.

  19. Behavior of radionuclides in sanitary landfills.

    PubMed

    Chang, K C; Chian, E S; Pohland, F G; Cross, W H; Roland, L; Kahn, B

    1984-01-01

    his study was undertaken to evaluate the possibility of disposing low-level radioactive waste in sanitary landfills with leachate containment to prevent environmental releases. To meet this objective, two simulated landfills, each 200 l. in volume and containing 55 kg of municipal refuse, were operated in the laboratory with simulated rainfall additions for a 9-month period to observe the extent to which radio-cobalt, -cesium, -strontium and tritium were leached into the liquid phase. One of the units was operated with leachate recycle, the other as a single pass control. Liquid samples were analyzed weekly for 3H, 58Co, 85Sr and 134Cs tracers. Weekly analyses were also performed for approximately 30 parameters to define the degree of stabilization of the waste. Major parameters included BOD, COD, pH and concentrations of specific organics, metals and gases. Concentrations of stable cobalt, strontium and cesium were also measured periodically. Soluble radioactivity levels in both systems were reduced by factors of 50 for 58Co, 5 for 85Sr and 7 for 134Cs, taking radioactive decay and dilution into account. Some radionuclide removal from the liquid phase was associated with major chemical changes in the landfills that occurred within 80 days for the control system and within 130 days for the recycle unit. Observed acid, sulfide, and CO2 concentrations suggested mechanisms for removing some of the radionuclides from leachate. Detection of 3H in the off-gas indicated that less than 1% of tritiated waste became airborne. The waste in the leachate recycle unit was more completely stabilized than in the control unit.

  20. Revisiting the Logan plot to account for non-negligible blood volume in brain tissue.

    PubMed

    Schain, Martin; Fazio, Patrik; Mrzljak, Ladislav; Amini, Nahid; Al-Tawil, Nabil; Fitzer-Attas, Cheryl; Bronzova, Juliana; Landwehrmeyer, Bernhard; Sampaio, Christina; Halldin, Christer; Varrone, Andrea

    2017-08-18

    Reference tissue-based quantification of brain PET data does not typically include correction for signal originating from blood vessels, which is known to result in biased outcome measures. The bias extent depends on the amount of radioactivity in the blood vessels. In this study, we seek to revisit the well-established Logan plot and derive alternative formulations that provide estimation of distribution volume ratios (DVRs) that are corrected for the signal originating from the vasculature. New expressions for the Logan plot based on arterial input function and reference tissue were derived, which included explicit terms for whole blood radioactivity. The new methods were evaluated using PET data acquired using [ 11 C]raclopride and [ 18 F]MNI-659. The two-tissue compartment model (2TCM), with which signal originating from blood can be explicitly modeled, was used as a gold standard. DVR values obtained for [ 11 C]raclopride using the either blood-based or reference tissue-based Logan plot were systematically underestimated compared to 2TCM, and for [ 18 F]MNI-659, a proportionality bias was observed, i.e., the bias varied across regions. The biases disappeared when optimal blood-signal correction was used for respective tracer, although for the case of [ 18 F]MNI-659 a small but systematic overestimation of DVR was still observed. The new method appears to remove the bias introduced due to absence of correction for blood volume in regular graphical analysis and can be considered in clinical studies. Further studies are however required to derive a generic mapping between plasma and whole-blood radioactivity levels.

  1. The physiological disposition of the uricosuric-saluretic agent (6,7-dichloro-2-methyl-1-oxo-2-phenyl-5-indanyloxy)acetic acid (MK-196) in the rat, dog, and monkey.

    PubMed

    Zacchei, A G; Wishousky, T I

    1976-01-01

    The physiological disposition of a new saluretic-uricosuric agent, (6,7-dichloro-2-methyl-1-oxo-2-phenyl-5-indanyloxy)acetic acid (MK-196), was studied in the rat, dog, and monkey. MK-196 was well absorbed and showed minimal metabolism in these species. Peak plasma levels of radioactivity and drug occurred 0.5-2 hr after oral administration at a dose of 2.5 mg/kg. Essentially all of the radioactivity present in the plasma during the first day was intact MK-196. Following a single dose, a long terminal half-life for plasma radioactivity was observed in the dog (approximately 68 hr) and monkey (approximately 105 hr). The chronic administration of MK-196 to dogs resulted in a dose-related plasma profile and showed no tendency to increase or decrease with dosing. However, upon repeated drug administration to monkeys, the plasma levels of drug increased and then decreased, possibly due to hypochloremia and secondary metabolic alkalosis. Fecal excretion was the predominant route of tracer elimination in the dog (approximately 80%) and rat (approximately 94%), whereas the monkey eliminated the majority of the dose (approximately 60%) via the urine. Minimal metabolism was noted in the three lower species; most of the urinary, plasma, and fecal radioactivity was accounted for as intact drug and its glucuronide conjugate. Three minor metabolites, which were present in dog bile, plasma, and urine, were characterized as: (l,7-dichloro-1alpha-hydroxy-2-methyl-2-phenyl-5-indanyloxy)acetic acid, I; (6,7-dichloro-2-(4-hydroxyphenyl)-2-methyl-2-oxo-5-indanyloxy)acetic acid, II; and 2-methyl-2-phenyl-5-hydroxy-6,7-dichloro-1-indanone, III. The monkey urine and plasma also contained small amounts of II.

  2. Sorption--desorption studies on granite. I. Initial studies of strontium, technetium, cesium, barium, cerium, europium, uranium, plutonium, and americium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erdal, B.R.; Aguilar, R.D.; Bayhurst, B.P.

    Distribution ratios were determined for sorption--desorption of radioactive tracers between the Climax Stock granite (quartz monzonite porphyry) obtained at Nevada Test Site and a water prepared to be resonably representative of the natural composition of water in equilibrium with the Climax Stock granite. The measurements were performed at 22 and 70{sup 0}C under atmospheric oxygen conditions. Elements given in order of increasing distribution coefficient at ambient temperature are: U(VI), Sr, Tc(VII), Ba, Ce(III), Cs, Eu(III), Pu, and Am. At 70{sup 0}C the order is: Tc(VII), Sr, Ce(III), Eu(III), Ba, Cs, Pu, and Am. The effects of surface area and mineralogymore » on sorption were also investigated.« less

  3. Quantifying Drosophila food intake: comparative analysis of current methodology

    PubMed Central

    Deshpande, Sonali A.; Carvalho, Gil B.; Amador, Ariadna; Phillips, Angela M.; Hoxha, Sany; Lizotte, Keith J.; Ja, William W.

    2014-01-01

    Food intake is a fundamental parameter in animal studies. Despite the prevalent use of Drosophila in laboratory research, precise measurements of food intake remain challenging in this model organism. Here, we compare several common Drosophila feeding assays: the Capillary Feeder (CAFE), food-labeling with a radioactive tracer or a colorimetric dye, and observations of proboscis extension (PE). We show that the CAFE and radioisotope-labeling provide the most consistent results, have the highest sensitivity, and can resolve differences in feeding that dye-labeling and PE fail to distinguish. We conclude that performing the radiolabeling and CAFE assays in parallel is currently the best approach for quantifying Drosophila food intake. Understanding the strengths and limitations of food intake methodology will greatly advance Drosophila studies of nutrition, behavior, and disease. PMID:24681694

  4. Historical and contemporary stable isotope tracer approaches to studying mammalian protein metabolism

    PubMed Central

    2016-01-01

    Over a century ago, Frederick Soddy provided the first evidence for the existence of isotopes; elements that occupy the same position in the periodic table are essentially chemically identical but differ in mass due to a different number of neutrons within the atomic nucleus. Allied to the discovery of isotopes was the development of some of the first forms of mass spectrometers, driven forward by the Nobel laureates JJ Thomson and FW Aston, enabling the accurate separation, identification, and quantification of the relative abundance of these isotopes. As a result, within a few years, the number of known isotopes both stable and radioactive had greatly increased and there are now over 300 stable or radioisotopes presently known. Unknown at the time, however, was the potential utility of these isotopes within biological disciplines, it was soon discovered that these stable isotopes, particularly those of carbon (13C), nitrogen (15N), oxygen (18O), and hydrogen (2H) could be chemically introduced into organic compounds, such as fatty acids, amino acids, and sugars, and used to “trace” the metabolic fate of these compounds within biological systems. From this important breakthrough, the age of the isotope tracer was born. Over the following 80 yrs, stable isotopes would become a vital tool in not only the biological sciences, but also areas as diverse as forensics, geology, and art. This progress has been almost exclusively driven through the development of new and innovative mass spectrometry equipment from IRMS to GC‐MS to LC‐MS, which has allowed for the accurate quantitation of isotopic abundance within samples of complex matrices. This historical review details the development of stable isotope tracers as metabolic tools, with particular reference to their use in monitoring protein metabolism, highlighting the unique array of tools that are now available for the investigation of protein metabolism in vivo at a whole body down to a single protein level. Importantly, it will detail how this development has been closely aligned to the technological development within the area of mass spectrometry. Without the dedicated development provided by these mass spectrometrists over the past century, the use of stable isotope tracers within the field of protein metabolism would not be as widely applied as it is today, this relationship will no doubt continue to flourish in the future and stable isotope tracers will maintain their importance as a tool within the biological sciences for many years to come. © 2016 The Authors. Mass Spectrometry Reviews Published by Wiley Periodicals, Inc. Mass Spec Rev PMID:27182900

  5. Tracer Transport Along a Vertical Fault Located in Welded Tuffs

    NASA Astrophysics Data System (ADS)

    Salve, R.; Liu, H.; Hu, Q.

    2002-12-01

    A near-vertical fault that intercepts the fractured welled tuff formation in the underground Exploratory Studies Facility (ESF) at Yucca Mountain, Nevada, has provided a unique opportunity to evaluate important hydrological parameters associated with faults (e.g., flow velocity, matrix diffusion, fault-fracture-matrix interactions). Alcove 8, which intersects the fault is located in the cross drift of the ESF, has been excavated for liquid releases through this fault and a network of fractures. Located 25 m below Alcove 8 in the main drift of the ESF, Niche 3 which also intercepts the fault, serves as the site for monitoring the wetting front and for collecting seepage following liquid releases in Alcove 8. To investigate the importance of matrix diffusion and the extent of area subject to fracture-matrix interactions, we released a mix of conservative tracers (pentafluorobenzoic acid [PFBA] and lithium bromide [LiBr]) along the fault. The ceiling of Niche 3 was blanketed with an array of trays to capture seepage, and seepage rates were continuously monitored by a water collection system connected to the trays. Additionally, a water sampling device, the passive-discreet water sampler (PDWS), was connected to three of the collections trays in Niche 3 into which water was seeping. The PDWS, designed to isolate continuous seepage from each tray into discreet samples for chemical analysis, remained connected to the trays over a period of three months. During this time, all water that seeped into the three trays was captured sequentially into sampling bottles and analyzed for concentrations of PFBA and LiBr. Water released along the fault initially traveled the 25 m vertical distance over a period of 36 days (at a velocity ~0.7 m/day). The seepage recovered in Niche 3 was less than 10% of the injected water with significant spatial and temporal fluctuations in seepage rates. Along a fast flow path, the benzoic tracer (PFBA) and LiBr were first detected ~12 days after they were released into the fault. Along slower flow paths the tracers appeared ~ two weeks later, with PFBA preceding the LiB. The differing travel times of the two conservative tracers suggests the impact of matrix diffusion in the transport process. This work was supported by the Director, Office of Civilian Radioactive Waste Management, U.S. Department of Energy, through Memorandum Purchase Order EA9013MC5X between Bechtel SAIC Company, LLC, and the Ernest Orlando Lawrence Berkeley National Laboratory (Berkeley Lab). The support is provided to Berkeley Lab through the U.S. Department of Energy Contract No. DE-AC03-76SF00098.

  6. Metabolic Relations between Methylxanthines and Methyluric Acids in Coffea L. 1

    PubMed Central

    Petermann, Joseph B.; Baumann, Thomas W.

    1983-01-01

    Metabolism of purine alkaloids in the leaves of Coffea dewevrei De Wild et Durand var excelsa Chev, Coffea liberica Bull ex Hiern and Coffea abeokutae Cramer was studied by analyzing leaf discs collected during vegetative development and by feeding the following radioactive tracers: [14C]theobromine, [14C]caffeine, and [14C]theacrine (1,3,7,9-tetramethyluric acid). Their principal metabolites were quantitatively and qualitatively determined. All three species convert the precursors to the same radioactive products, and proceed through the same four maturity stages characterized by the alkaloid accumulation pattern and by a particular transformation potency: (stage 1) young plant accumulating caffeine, transforms theobromine to caffeine; (stage 2) caffeine is gradually replaced by theacrine, theobromine and caffeine are converted to theacrine; (stage 3) theacrine disappears whereas liberine (O(2), 1,9-thrimethyluric acid) accumulates, theacrine is metabolized to liberine; (stage 4) branched-out plant containing liberine but no theacrine, caffeine is converted rapidly to liberine via theacrine. Methylliberine (O(2),1,7,9-tetramethyluric acid), presumably the direct precursor of liberine, is occasionally found in low concentrations at stage 3 and 4. The collective term `liberio-excelsoid' introduced by geneticists for the numerous races or species of Pachycoffea is in accordance with the phytochemical equality found in this work. PMID:16663351

  7. Multi-modal in cellulo evaluation of NPR-C targeted C-ANF-peptide and C-ANF-comb nanoparticles

    NASA Astrophysics Data System (ADS)

    Shokeen, Monica; Pressly, Eric; Connal, Luke; Liu, Yongjian; Hawker, Craig J.; Woodard, Pamela K.; Anderson, Carolyn J.; Achilefu, Samuel; Welch, Michael J.

    2012-03-01

    Natriuretic peptides (NPs) are clinical markers of heart disease that have anti-proliferative and anti-migratory effects on vascular smooth-muscle cells (VSMCs). In atherosclerosis, NPs participate in vascular remodeling, where the expression of NP clearance receptors (NPR-Cs) is upregulated both in the endothelium and in VSMCs[1-3]. In this study, we investigated the enhanced targeting potential of novel multifunctional nanoprobes conjugated with multiple copies of a C-type atrial natriuretic factor (C-ANF) peptide fragment to target NPR-C transfected cells. The cell binding results of the NPR-C targeted nanoprobes were compared with that of the C-ANF peptide fragment alone. The nanoprobe and peptide structures contain the chelator DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) for labeling with the PET tracer, 64Cu, for radioactive assays and luminescent Eu (III) for confocal cell imaging. Cell assays performed with the radioactive nanoprobe and peptide demonstrated higher cell binding of the targeted nanoprobe comapred with the peptide alone (8.63+/-1.67 vs. 1.13+/-0.06). The targeting specificity of both moieties was tested by using the control cell lines NPR-A and NPR-B, and receptor mediated uptake was demonstrated by reduced uptake in the presence of excess unlabeled respective probes.

  8. Plasma pharmacokinetics, whole-body distribution, metabolism, and radiation dosimetry of 68Ga bombesin antagonist BAY 86-7548 in healthy men.

    PubMed

    Roivainen, Anne; Kähkönen, Esa; Luoto, Pauliina; Borkowski, Sandra; Hofmann, Birte; Jambor, Ivan; Lehtiö, Kaisa; Rantala, Tuija; Rottmann, Antje; Sipilä, Henri; Sparks, Rick; Suilamo, Sami; Tolvanen, Tuula; Valencia, Ray; Minn, Heikki

    2013-06-01

    This first-in-human study investigated the safety, tolerability, metabolism, pharmacokinetics, biodistribution, and radiation dosimetry of (68)Ga-bombesin antagonist (68)Ga-DOTA-4-amino-1-carboxymethylpiperidine-d-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH2 (BAY 86-7548). Five healthy men underwent dynamic whole-body PET/CT after an intravenous injection of BAY 86-7548 (138 ± 5 MBq). Besides total radioactivity, plasma samples were analyzed by radio-high-performance liquid chromatography for metabolism of the tracer. Dosimetry was calculated using the OLINDA/EXM software. Three radioactive plasma metabolites were detected. The proportion of unchanged BAY 86-7548 decreased from 92% ± 9% at 1 min after injection to 19% ± 2% at 65 min. The organs with the highest absorbed doses were the urinary bladder wall (0.62 mSv/MBq) and the pancreas (0.51 mSv/MBq). The mean effective dose was 0.051 mSv/MBq. BAY 86-7548 was well tolerated by all subjects. Intravenously injected BAY 86-7548 is safe, and rapid metabolism is demonstrated. A 150-MBq injection of BAY 86-7548 results in an effective dose of 7.7 mSv, which could be reduced to 5.7 mSv with frequent bladder voids.

  9. The separation of 99Tc from low and medium-level radioactive wastes and its determination by inductively coupled plasma mass spectrometry.

    PubMed

    Hepiegne, P; Dall'ava, D; Clement, R; Degros, J P

    1995-06-01

    A chemical separation method has been developed for the determination of (99)Tc in various types of radioactive wastes. Such a method includes (i) fusion with NaOH, (ii) extraction in a column containing methyltrioctylammonium chloride, (iii) extraction by solvent with N-benzoyl-N-phenylhydroxylamine and, (iv) measurement by inductively-coupled plasma mass spectrometry (ICP-MS). From the performance standpoint, the recovery of (99)Tc, using (99m)Tc as a yield tracer, is higher than 70%. This analytical method, as developed, ensures effective decontamination with respect to the radionuclides, insofar the decontamination factors are greater than 10(+5), whenever the residual activity may be measured. Taking into account a 3sigma counting error, the detection limit obtained with the ICP-MS technique is 1.9 mBq/ml; the method enabling hence to detect activities as low as 0.3 Bq/g, with analysed samples of 0.2 g and a radiochemical yield of 70%. Studies have been dedicated to the (99)Tc measurement, using the electrothermal vaporization ICP-MS technique, which lowers the detection limit by a factor 10, with the standard solution (0.3 pg/ml), compared with the previous ICP-MS technique.

  10. Automated cassette-based production of high specific activity [203/212Pb]peptide-based theranostic radiopharmaceuticals for image-guided radionuclide therapy for cancer.

    PubMed

    Li, Mengshi; Zhang, Xiuli; Quinn, Thomas P; Lee, Dongyoul; Liu, Dijie; Kunkel, Falk; Zimmerman, Brian E; McAlister, Daniel; Olewein, Keith; Menda, Yusuf; Mirzadeh, Saed; Copping, Roy; Johnson, Frances L; Schultz, Michael K

    2017-09-01

    A method for preparation of Pb-212 and Pb-203 labeled chelator-modified peptide-based radiopharmaceuticals for cancer imaging and radionuclide therapy has been developed and adapted for automated clinical production. Pre-concentration and isolation of radioactive Pb2+ from interfering metals in dilute hydrochloric acid was optimized using a commercially-available Pb-specific chromatography resin packed in disposable plastic columns. The pre-concentrated radioactive Pb2+ is eluted in NaOAc buffer directly to the reaction vessel containing chelator-modified peptides. Radiolabeling was found to proceed efficiently at 85°C (45min; pH 5.5). The specific activity of radiolabeled conjugates was optimized by separation of radiolabeled conjugates from unlabeled peptide via HPLC. Preservation of bioactivity was confirmed by in vivo biodistribution of Pb-203 and Pb-212 labeled peptides in melanoma-tumor-bearing mice. The approach has been found to be robustly adaptable to automation and a cassette-based fluid-handling system (Modular Lab Pharm Tracer) has been customized for clinical radiopharmaceutical production. Our findings demonstrate that the Pb-203/Pb-212 combination is a promising elementally-matched radionuclide pair for image-guided radionuclide therapy for melanoma, neuroendocrine tumors, and potentially other cancers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Preliminary Test Results of Heshe Hydrogeological Experimental Well Station in Taiwan

    NASA Astrophysics Data System (ADS)

    Chuang, P.; Liu, C.; Lin, M.; Chan, W.; Lee, T.; Chia, Y.; Teng, M.; Liu, C.

    2013-12-01

    Safe disposal of radioactive waste is a critical issue for the development of nuclear energy. The design of final disposal system is based on the concept of multiple barriers which integrate the natural barriers and engineering barriers for long-term isolation of radioactive wastes. As groundwater is the major medium that can transport radionuclides to our living environment, it is essential to characterize groundwater flow at the disposal site. Taiwan is located at the boundary between the Eurasian plate and the Philippine Sea plate. Geologic formations are often fractured due to tectonic compression and extension. In this study, a well station for the research and development of hydrogeological techniques was established at the Experimental Forest of the National Taiwan University in central Taiwan. There are 10 testing wells, ranging in depth from 25 m to 100 m, at the station. The bedrock beneath the regolith is highly fractured mudstone. As fracture is the preferential pathway of the groundwater flow, the focus of in-situ tests is to investigate the location of permeable fractures and the connection of permeable fractures. Several field tests have been conducted, including geophysical logging, heat-pulse flowmeter, hydraulic test, tracer test and double packer test, for the development of advanced technologies to detect the preferential groundwater flow in fractured rocks.

  12. Monte Carlo assessment of the finger shallow dose from direct contact with a microcentrifuge tube containing common biotechnology isotopes in solution.

    PubMed

    Cutright, Dan; Medich, David; Ring, Joseph

    2012-04-01

    Eppendorf tubes often are used in biomedical research labs and contain radioactive tracers. Although the associated direct contact finger doses are typically small, it is suggested (and in line with the principle of ALARA) to handle these tubes from the cap of the tube. When containing radioactive material, handling a tube near the bottom conical section would unnecessarily increase the skin dose to the fingers. This investigation modeled a 2.0-mL Eppendorf tube containing various individual beta emitting isotopes commonly used in a biomedical research environment (i.e., (14)C, (3)H, (131)I, (32)P, and (35)S) to determine the skin dose when directly handling the tube at the cap end and when handling it at the bottom conical section. The primary goal of this paper is to assess how significantly this dose is altered by handling geometry. The skin dose to a single finger was calculated with Monte Carlo simulations using MCNP5 and determined at a depth of 0.007 cm(2) in water averaged over 10 cm as described in 10CFR20. Results show that the dose rate may vary by as much as a factor of 700 depending on handling geometry.

  13. Development of a PET/OMRI combined system for simultaneous imaging of positron and free radical probes for small animals.

    PubMed

    Yamamoto, Seiichi; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Ichikawa, Kazuhiro; Nakao, Motonao; Kato, Katsuhiko; Hatazawa, Jun

    2016-10-01

    Positron emission tomography (PET) has high sensitivity for imaging radioactive tracer distributions in subjects. However, it is not possible to image free radical distribution in a subject by PET. Since free radicals are quite reactive, they are related to many diseases, including but not limited to cancer, inflammation, strokes, and heart disease. The Overhauser enhanced magnetic resonance imaging (OMRI) is so far the only method that images free radical distribution in vivo. By combining PET and OMRI, a new hybrid imaging modality might be developed that can simultaneously image the radioactive tracer and free radical distributions. For this purpose, the authors developed a PET/OMRI combined system for small animals. The developed PET/OMRI system used an optical fiber-based PET system combined with a permanent magnet-based OMRI system. The optical fiber-based PET system uses flexible optical fiber bundles. Eight optical fiber-based block detectors were arranged in a 56 mm diameter ring to form a PET system. The LGSO blocks were located inside the field-of-view (FOV) of the OMRI, and the position sensitive photomultiplier tubes were positioned behind the OMRI to minimize the interference between the PET and the OMRI. The OMRI system used a 0.0165 T permanent magnet. The system has an electron spin resonance coil to enhance the MRI signal using the Overhauser effect to image the free radical in the FOV of the PET/OMRI system. The spatial resolution and sensitivity of the optical fiber-based PET system were 1.2 mm FWHM and 1.2% at the central FOV, respectively. The OMRI system imaged the distribution of a nitroxyl radical (NXR) solution. The interference between PET and OMRI was small. Simultaneous imaging of the positron radiotracer and the NXR solution was successfully conducted with the developed PET/OMRI system for phantom and small animal studies. The authors developed a PET/OMRI combined system with the potential to provide interesting new results in molecular imaging research, such as in vivo molecular and free radical distributions.

  14. A combined radio- and stable-isotopic study of a California coastal aquifer system

    USGS Publications Warehouse

    Swarzenski, Peter W.; Baskaran, Mark; Rosenbauer, Robert J.; Edwards, Brian D.; Land, Michael

    2013-01-01

    Stable and radioactive tracers were utilized in concert to characterize geochemical processes in a complex coastal groundwater system and to provide constraints on the kinetics of rock/water interactions. Groundwater samples from wells within the Dominguez Gap region of Los Angeles County, California were analyzed for a suite of major cations (Na+, K+, Mg2+, Ca2+) and anions (Cl−, SO42−), silica, alkalinity, select trace elements (Ba, B, Sr), dissolved oxygen, stable isotopes of hydrogen (δD), oxygen (δ18O), dissolved inorganic carbon (δ13CDIC), and radioactive isotopes (3H, 222Rn and 223,224,226,228Ra). In the study area, groundwater may consist of a complex mixture of native groundwater, intruded seawater, non-native injected water, and oil-field brine water. In some wells, Cl− concentrations attained seawater-like values and in conjunction with isotopically heavier δ18O values, these tracers provide information on the extent of seawater intrusion and/or mixing with oil-field brines. Groundwater 3H above 1 tritium unit (TU) was observed only in a few select wells close to the Dominguez Gap area and most other well groundwater was aged pre-1952. Based on an initial 14C value for the study site of 90 percent modern carbon (pmc), groundwater age estimates likely extend beyond 20 kyr before present and confirm deep circulation of some native groundwater through multiple aquifers. Enriched values of groundwater δ13CDIC in the absence of SO42− imply enhanced anaerobic microbial methanogenesis. While secular equilibrium was observed for 234U/238U (activity ratios ~1) in host matrices, strong isotopic fractionation in these groundwater samples can be used to obtain information of adsorption/desorption kinetics. Calculated Ra residence times are short, and the associated desorption rate constant is about three orders of magnitude slower than that of the adsorption rate constant. Combined stable- and radio-isotopic results provide unique insights into aquifer characteristics, such as geochemical cycling, rock/water interactions, and subsurface transport and mixing.

  15. THE DIAGNOSIS OF FEMALE GENITAL TUMORS WITH RADIOISOTOPES (in Italian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paroli, G.; Zacutti, A.; Turchetti, G.

    1963-04-01

    The use of radioactive tracer substances for demonstrating the early stages of tumors of the genital organs is considered. As regards the external genital organs, patients with acute or chronic vulvitis, kraurosis vulvar with or without leukoplakia, and cancer were examined by measuring the radioactivity with a Geiger-Muller counter 6, 24, and 48 hr after the injection of 3 C of P/sup 32/ per kg of body weight. The results indicate that investigation of the uptake of radiophorphorus in the vulva can yield valuable information as to the nature of the various conditions considered. Measurements were made with a Geiger-Mullermore » probe counter over the portio in normal cases and in patients with different types of disease (erosions, polyps, cancer) at various intervals after the injection of the same dose of P/sup 32/ intravenously. It was shown that a high uptake can be demonstrated in vivo in the neoplastic tissues as compared with the normal tissues. The difference is most significant between the 48th and 72nd hr, when the values measured over erosions and polyps remain within the range of normal. The method therefore makes it possible to identify areas of neoplastic tissue in the portio and to establish their boundaries faily well. The uptake of P/sup 32/ was investigated in cases of cancer of the neck of the uterus before and after radium therapy. It was found that the method is valuable in establishing the prognosis and as a method for controlling the effects of irradiation. Finally, the results obtained in the field of the diagnosis of ovarian tumors with the use of gamma-emitting tracer substances (radioiodinated human serum albumin and I/sup 131/-labeled diiodofluorescein) and those of intra- operative investigation of lymph nodes containing metastases in cases of cancer of the cervix after the administration of P/sup 32/ are presented. The importance of the method, especially as regards the possibilities of completely removing all lymph nodes involved by the tumor, is discussed. (auth)« less

  16. Validation of an enzyme-linked immunosorbent assay (ELISA) for the measurement of canine S100A12.

    PubMed

    Heilmann, Romy M; Cranford, Shannon M; Ambrus, Andy; Grützner, Niels; Schellenberg, Stefan; Ruaux, Craig G; Suchodolski, Jan S; Steiner, Jörg M

    2016-03-01

    Canine S100 calcium-binding protein A12 (cS100A12) shows promise as biomarker of inflammation in dogs. A previously developed cS100A12-radioimmunoassay (RIA) requires radioactive tracers and is not sensitive enough for fecal cS100A12 concentrations in 79% of tested healthy dogs. An ELISA assay may be more sensitive than RIA and does not require radioactive tracers. The purpose of the study was to establish a sandwich ELISA for serum and fecal cS100A12, and to establish reference intervals (RI) for normal healthy canine serum and feces. Polyclonal rabbit anti-cS100A12 antibodies were generated and tested by Western blotting and immunohistochemistry. A sandwich ELISA was developed and validated, including accuracy and precision, and agreement with cS100A12-RIA. The RI, stability, and biologic variation in fecal cS100A12, and the effect of corticosteroids on serum cS100A12 were evaluated. Lower detection limits were 5 μg/L (serum) and 1 ng/g (fecal), respectively. Intra- and inter-assay coefficients of variation were ≤ 4.4% and ≤ 10.9%, respectively. Observed-to-expected ratios for linearity and spiking recovery were 98.2 ± 9.8% (mean ± SD) and 93.0 ± 6.1%, respectively. There was a significant bias between the ELISA and the RIA. The RI was 49-320 μg/L for serum and 2-484 ng/g for fecal cS100A12. Fecal cS100A12 was stable for 7 days at 23, 4, -20, and -80°C; biologic variation was negligible but variation within one fecal sample was significant. Corticosteroid treatment had no clinically significant effect on serum cS100A12 concentrations. The cS100A12-ELISA is a precise and accurate assay for serum and fecal cS100A12 in dogs. © 2016 American Society for Veterinary Clinical Pathology.

  17. Unconventional Aqueous Humor Outflow: A Review

    PubMed Central

    Johnson, Mark; McLaren, Jay W.; Overby, Darryl R.

    2016-01-01

    Aqueous humor flows out of the eye primarily through the conventional outflow pathway that includes the trabecular meshwork and Schlemm's canal. However, a fraction of aqueous humor passes through an alternative or ‘unconventional’ route that includes the ciliary muscle, supraciliary and suprachoroidal spaces. From there, unconventional outflow may drain through two pathways: a uveoscleral pathway where aqueous drains across the sclera to be resorbed by orbital vessels, and a uveovortex pathway where aqueous humor enters the choroid to drain through the vortex veins. We review the anatomy, physiology and pharmacology of these pathways. We also discuss methods to determine unconventional outflow rate, including direct techniques that use radioactive or fluorescent tracers recovered from tissues in the unconventional pathway and indirect methods that estimate unconventional outflow based on total outflow over a range of pressures. Indirect methods are subject to a number of assumptions and generally give poor agreement with tracer measurements. We review the variety of animal models that have been used to study conventional and unconventional outflow. The mouse appears to be a promising model because it captures several aspects of conventional and unconventional outflow dynamics common to humans, although questions remain regarding the magnitude of unconventional outflow in mice. Finally, we review future directions. There is a clear need to develop improved methods for measuring unconventional outflow in both animals and humans. PMID:26850315

  18. Extraterrestrial 3He as a tracer of marine sediment transport and accumulation

    NASA Astrophysics Data System (ADS)

    Marcantonio, Franco; Anderson, Robert F.; Stute, Martin; Kumar, Niraj; Schlosser, Peter; Mix, Alan

    1996-10-01

    THE deposition rate of deep-sea sediments, and their focused redeposition by deep-sea currents, can be evaluated from analyses of sedimentary 230Th with a temporal resolution limited only by bioturbation6,7,10,11. 230Th is produced uniformly throughout the ocean by radioactive decay of dissolved 234U and is removed sufficiently fast by sorption onto sinking particles to act as a 'constant-flux' tracer of sedimentation rates. But the half-life of 230Th (75 kyr) limits its use for this purpose to the past 200-250 kyr. Here we explore the use of extraterrestrial 3He from interplanetary dust particles1-4 (IDPs) as a constant-flux proxy that is free from this limitation. A comparison of 3He with 230Th in two cores from the equatorial Pacific Ocean indicates that the variability in the mean flux of IDPs over the past 200 kyr is less than 75%. But in contrast to this relatively constant rate of supply of 3He to the deep sea, the local burial rates of 3He and 230Th have varied by a factor of five over the past 450 and 200 kyr, respect-ively. We interpret this variability as reflecting sediment focusing, with a temporal pattern that suggests regular cycles of climate-driven reorganization of near-bottom currents in the deep Pacific Ocean.

  19. Experimental evaluation of radioiodinated sennoside B as a necrosis-avid tracer agent.

    PubMed

    Zhang, Dongjian; Huang, Dejian; Ji, Yun; Jiang, Cuihua; Li, Yue; Gao, Meng; Yao, Nan; Liu, Xuejiao; Shao, Haibo; Jing, Su; Ni, Yicheng; Yin, Zhiqi; Zhang, Jian

    2015-02-01

    Necrosis-avid agents are a class of compounds that selectively accumulate in the necrotic tissues after systemic administration, which can be used for in vivo necrosis imaging and targeted therapies. In order to search for a necrosis-avid tracer agent with improved drugability, we labelled iodine-131 on sennoside B (SB) as a naturally occurring median dianthrone compound. The necrosis targetability and clearance properties of (131)I-SB were evaluated in model rats with liver and muscle necrosis. On SPECT/CT images, a "hot spot" in the infarcted liver lobe and necrotic muscle was persistently observed at 24 h and 72 h post-injection (p.i.). Gamma counting of the tissues of interest revealed a radioactivity ratio of necrotic to viable liver at 4.6 and 3.4 and of necrotic to viable muscle at 7.0 and 8.8 at 24 h and 72 h p.i., respectively. The good match of autoradiographs and fluoromicroscopic images with corresponding histochemical staining suggested preferential uptake of (131)I-SB in necrotic tissue. Pharmacokinetic study revealed that (131)I-SB has an elimination half-life of 8.6 h. This study indicates that (131)I-SB shows not only prominent necrosis avidity but also favourable pharmacokinetics, which may serve as a potential necrosis-avid diagnostic agent for assessment of tissue viability.

  20. Targeting prostate cancer: Prostate-specific membrane antigen based diagnosis and therapy.

    PubMed

    Wüstemann, Till; Haberkorn, Uwe; Babich, John; Mier, Walter

    2018-05-17

    The high incidence rates of prostate cancer (PCa) raise demand for improved therapeutic strategies. Prostate tumors specifically express the prostate-specific membrane antigen (PSMA), a membrane-bound protease. As PSMA is highly overexpressed on malignant prostate tumor cells and as its expression rate correlates with the aggressiveness of the disease, this tumor-associated biomarker provides the possibility to develop new strategies for diagnostics and therapy of PCa. Major advances have been made in PSMA targeting, ranging from immunotherapeutic approaches to therapeutic small molecules. This review elaborates the diversity of PSMA targeting agents while focusing on the radioactively labeled tracers for diagnosis and endoradiotherapy. A variety of radionuclides have been shown to either enable precise diagnosis or efficiently treat the tumor with minimal effects to nontargeted organs. Most small molecules with affinity for PSMA are based on either a phosphonate or a urea-based binding motif. Based on these pharmacophores, major effort has been made to identify modifications to achieve ideal pharmacokinetics while retaining the specific targeting of the PSMA binding pocket. Several tracers have now shown excellent clinical usability in particular for molecular imaging and therapy as proven by the efficiency of theranostic approaches in current studies. The archetypal expression profile of PSMA may be exploited for the treatment with alpha emitters to break radioresistance and thus to bring the power of systemic therapy to higher levels. © 2018 Wiley Periodicals, Inc.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mironenko, V.A.; Rumynin, V.G.; Konosavsky, P.K.

    Mathematical models of the flow and tracer tests in fractured aquifers are being developed for the further study of radioactive wastes migration in round water at the Lake Area, which is associated with one of the waste disposal site in Russia. The choice of testing methods, tracer types (chemical or thermal) and the appropriate models are determined by the nature of the ongoing ground-water pollution processes and the hydrogeological features of the site under consideration. Special importance is attached to the increased density of wastes as well as to the possible redistribution of solutes both in the liquid phase andmore » in the absorbed state (largely, on fracture surfaces). This allows for studying physical-and-chemical (hydrogeochemical) interaction parameters which are hard to obtain (considering a fractured structure of the rock mass) in laboratory. Moreover, a theoretical substantiation is being given to the field methods of studying the properties of a fractured stratum aimed at the further construction of the drainage system or the subsurface flow barrier (cutoff wall), as well as the monitoring system that will evaluate the reliability of these ground-water protection measures. The proposed mathematical models are based on a tight combination of analytical and numerical methods, the former being preferred in solving the principal (2D axisymmetrical) class of the problems. The choice of appropriate problems is based on the close feedback with subsequent field tests in the Lake Area. 63 refs.« less

  2. Formation of nonextractable soil residues: A stable isotope approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richnow, H.H.; Eschenback, A.; Mahro, B.

    1999-11-01

    Stable carbon isotopic measurements were employed to characterize the transformation of a {sup 13}C-labeled polycyclic aromatic hydrocarbon (PAH), anthracene, in a closed soil bioreactor system. The {sup 13}C-label was used to calculate a carbon mass balance including mineralization and the formation of nonextractable soil-bound residues. Similar results were obtained from {sup 13}C-labeled carbon and {sup 14}C-labeled carbon mass balance calculations for separate batch experiments with labeled anthracene. In concentration ranges typical for real PAH-contaminated sites, the sensitivity of the {sup 13}C tracer method meets the requirements of classical radiotracer experiments. Therefore, the authors balancing method based on stable isotope-labeled chemicalsmore » may supplement or substitute radiotracer experiments under many circumstances. One major advantage of using stable isotope-labeled tracers is the possible application in transformation studies where the use of radioactive substances is of environmental concern. The transformation of {sup 13}C-labeled PAH into nonextractable residues clearly depends on the metabolic activity of the soil microflora and occurs during an early phase of biodegradation. Successive contamination of the soil by anthracene leads to a progressive adaptation of the microflora to a complete mineralization of anthracene in the soil. The extent of residue formation is controlled by the capability of the microflora to degrade the contaminant. Results of long-term experiments indicate that nonextractable residues are relatively stable over time.« less

  3. Human (13)N-ammonia PET studies: the importance of measuring (13)N-ammonia metabolites in blood.

    PubMed

    Keiding, Susanne; Sørensen, Michael; Munk, Ole Lajord; Bender, Dirk

    2010-03-01

    Dynamic (13)N-ammonia PET is used to assess ammonia metabolism in brain, liver and muscle based on kinetic modeling of metabolic pathways, using arterial blood (13)N-ammonia as input function. Rosenspire et al. (1990) introduced a solid phase extraction procedure for fractionation of (13)N-content in blood into (13)N-ammonia, (13)N-urea, (13)N-glutamine and (13)N-glutamate. Due to a radioactive half-life for (13)N of 10 min, the procedure is not suitable for blood samples taken beyond 5-7 min after tracer injection. By modifying Rosenspire's method, we established a method enabling analysis of up to 10 blood samples in the course of 30 min. The modified procedure was validated by HPLC and by 30-min reproducibility studies in humans examined by duplicate (13)N-ammonia injections with a 60-min interval. Blood data from a (13)N-ammonia brain PET study (from Keiding et al. 2006) showed: (1) time courses of (13)N-ammonia fractions could be described adequately by double exponential functions; (2) metabolic conversion of (13)N-ammonia to (13)N-metabolites were in the order: healthy subjects > cirrhotic patients without HE > cirrhotic patients with HE; (3) kinetics of initial tracer distribution in tissue can be assessed by using total (13)N-concentration in blood as input function, whereas assessment of metabolic processes requires (13)N-ammonia measurements.

  4. Characterization of cathode keeper wear by surface layer activation

    NASA Technical Reports Server (NTRS)

    Polk, James E.

    2003-01-01

    In this study, the erosion rates of the discharge cathode keeper in a 30 cm NSTAR configuration ion thruster were measured using a technique known as Surface Layer Activation (SLA). This diagnostic technique involves producing a radioactive tracer in a given surface by bombardment with high energy ions. The decrease in activity of the tracer material may be monitored as the surface is subjected to wear processes and correlated to a depth calibration curve, yielding the eroded depth. Analysis of the activities was achieved through a gamma spectroscopy system. The primary objectives of this investigation were to reproduce erosion data observed in previous wear studies in order to validate the technique, and to determine the effect of different engine operating parameters on erosion rate. The erosion profile at the TH 15 (23 kw) setting observed during the 8200 hour Life Demonstration Test (LDT) was reproduced. The maximum keeper erosion rate at this setting was determined to be 0.085 pm/hr. Testing at the TH 8 (1.4 kw) setting demonstrated lower erosion rates than TH 15, along with a different wear profile. Varying the keeper voltage was shown to have a significant effect on the erosion, with a positive bias with respect to cathode potential decreasing the erosion rate significantly. Accurate measurements were achieved after operating times of only 40 to 70 hours, a significant improvement over other erosion diagnostic methods.

  5. Assessment of the Revised 3410 Building Filtered Exhaust Stack Sampling Probe Location

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Xiao-Ying; Recknagle, Kurtis P.; Glissmeyer, John A.

    2013-12-01

    In order to support the air emissions permit for the 3410 Building, Pacific Northwest National Laboratory performed a series of tests in the exhaust air discharge from the reconfigured 3410 Building Filtered Exhaust Stack. The objective was to determine whether the location of the air sampling probe for emissions monitoring meets the applicable regulatory criteria governing such effluent monitoring systems. In particular, the capability of the air sampling probe location to meet the acceptance criteria of ANSI/HPS N13.1-2011 , Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities was determined. The qualification criteriamore » for these types of stacks address 1) uniformity of air velocity, 2) sufficiently small flow angle with respect to the axis of the duct, 3) uniformity of tracer gas concentration, and 4) uniformity of tracer particle concentration. Testing was performed to conform to the quality requirements of NQA-1-2000. Fan configurations tested included all fan combinations of any two fans at a time. Most of the tests were conducted at the normal flow rate, while a small subset of tests was performed at a slightly higher flow rate achieved with the laboratory hood sashes fully open. The qualification criteria for an air monitoring probe location are taken from ANSI/HPS N13.1-2011 and are paraphrased as follows with key results summarized: 1. Angular Flow—The average air velocity angle must not deviate from the axis of the stack or duct by more than 20°. Our test results show that the mean angular flow angles at the center two-thirds of the ducts are smaller than 4.5% for all testing conditions. 2. Uniform Air Velocity—The acceptance criterion is that the COV of the air velocity must be ≤ 20% across the center two thirds of the area of the stack. Our results show that the COVs of the air velocity across the center two-thirds of the stack are smaller than 2.9% for all testing conditions. 3. Uniform Concentration of Tracer Gases—The uniformity of the concentration of potential contaminants is first tested using a tracer gas to represent gaseous effluents. The tracer is injected downstream of the fan outlets and at the junction downstream fan discharges meet. The acceptance criteria are that 1) the COV of the measured tracer gas concentration is ≤20% across the center two-thirds of the sampling plane and 2) at no point in the sampling plane does the concentration vary from the mean by >30%. Our test results show that 1) the COV of the measured tracer gas concentration is < 2.9% for all test conditions and 2) at no point in the sampling plane does the concentration vary from the mean by >6.5%. 4. Uniform Concentration of Tracer Particles—Tracer particles of 10-μm aerodynamic diameter are used for the second demonstration of concentration uniformity. The acceptance criterion is that the COV of particle concentration is ≤ 20% across the center two thirds of the sampling plane. Our test results indicate that the COV of particle concentration is <9.9% across the center two-thirds of the sampling plane among all testing conditions. Thus, the reconfigured 3410 Building Filtered Exhaust Stack was determined to meet the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Changes to the system configuration or operations outside the bounds described in this report (e.g., exhaust stack velocity changes, relocation of sampling probe, and addition of fans) may require re-testing or re-evaluation to determine compliance.« less

  6. [Determination of ventricular volumes by a non-geometric method using gamma-cineangiography].

    PubMed

    Faivre, R; Cardot, J C; Baud, M; Verdenet, J; Berthout, P; Bidet, A C; Bassand, J P; Maurat, J P

    1985-08-01

    The authors suggest a new way of determining ventricular volume by a non-geometric method using gamma-cineangiography. The results obtained by this method were compared with those obtained by a geometric methods and contrast ventriculography in 94 patients. The new non-geometric method supposes that the radioactive tracer is evenly distributed in the cardiovascular system so that blood radioactivity levels can be measured. The ventricular volume is then equal to the ratio of radioactivity in the LV zone to that of 1 ml of blood. Comparison of the radionuclide and angiographic data in the first 60 patients showed systematic values--despite a satisfactory statistical correlation (r = 0.87, y = 0.30 X + 6.3). This underestimation is due to the phenomenon of attenuation related to the depth of the heart in the thoracic cage and to autoabsorption at source, the degree of which depends on the ventricular volume. An empirical method of calculation allows correction for these factors by taking into account absorption in the tissues by relating to body surface area and autoabsorption at source by correcting for the surface of isotopic ventricular projection expressed in pixels. Using the data of this empirical method, the correction formula for radionuclide ventricular volume is obtained by a multiple linear regression: corrected radionuclide volume = K X measured radionuclide volume (Formula: see text). This formula was applied in the following 34 patients. The correlation between the uncorrected and corrected radionuclide volumes and the angiographic volumes was improved (r = 0.65 vs r = 0.94) and the values were more accurate (y = 0.18 X + 26 vs y = 0.96 X + 1.5).(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Impact of raking and bioturbation-mediated ecological manipulation on sediment-water phosphorus diagenesis: a mesocosm study supported with radioactive signature.

    PubMed

    Biswas, Jayanta K; Hazra, Saumen; Majumdar, Jayjit; Mandal, Sushil K; Shaheen, Sabry M; Sarkar, Santosh K; Meissner, Ralph; Meers, Erik; Rinklebe, Jörg

    2017-12-01

    The study examined the impact of raking and fish bioturbation on modulating phosphorus (P) concentrations in the water and sediment under different trophic conditions. An outdoor experiment was set to monitor physicochemical and microbiological parameters of water and sediment influencing P diagenesis. A pilot study with radioactive 32 P was also performed under the agency of raking and bacteria (Bacillus sp.). Raking was more effective in release of P under unfertilized conditions by significantly enhancing orthophosphate (35%) and soluble reactive phosphate (31.8%) over respective controls. Bioturbation increased total and available P in sediments significantly as compared to control. The rates of increase were higher in the unfertilized conditions (17.6-28.4% for total P and 12.2 to 23.2% for available P) than the fertilized ones (6.5-12.4% for total P and 9.1 to 15% for available P). The combined effects of raking and bioturbation on orthophosphate and soluble reactive phosphate were also stronger under unfertilized state (54.5 and 81.8%) than fertilized ones (50 and 70%). The tracer signature showed that coupled action of introduced bacteria and repeated raking resulted in 59.2, 23 and 16% higher counts of radioactive P than the treatments receiving raking once, repeated raking and bacteria inoculation, respectively. Raking alone or in sync with bioturbation exerted pronounced impact on P diagenesis through induction of coupled mineralization and nutrient release. It has significant implication for performing regular raking of fish-farm sediments and manipulation of bottom-grazing fish to regulate mineralization of organic matter and release of obnoxious gases from the system. Further, they synergistically can enhance the buffering capacity against organic overload and help to maintain aquatic ecosystem health.

  8. Brain penetration of telmisartan, a unique centrally acting angiotensin II type 1 receptor blocker, studied by PET in conscious rhesus macaques.

    PubMed

    Noda, Akihiro; Fushiki, Hiroshi; Murakami, Yoshihiro; Sasaki, Hiroshi; Miyoshi, Sosuke; Kakuta, Hirotoshi; Nishimura, Shintaro

    2012-11-01

    Telmisartan is a widely used, long-acting antihypertensive agent. Known to be a selective angiotensin II type 1 (AT(1)) receptor (AT(1)R) blocker (ARB), telmisartan acts as a partial agonist of peroxisome proliferator-activated receptor-gamma (PPAR-γ) and inhibits centrally mediated effects of angiotensin II in rats following peripheral administration, although the brain penetration of telmisartan remains unclear. We investigated the brain concentration and localization of telmisartan using (11)C-labeled telmisartan and positron emission tomography (PET) in conscious rhesus macaques. Three male rhesus macaques were bolus intravenously administered [(11)C]telmisartan either alone or as a mixture with unlabeled telmisartan (1mg/kg). Dynamic PET images were acquired for 95min following administration. Blood samples were collected for the analysis of plasma concentration and metabolites, and brain and plasma concentrations were calculated from detected radioactivity using the specific activity of the administered drug preparation, in which whole blood radioactivity was used for the correction of intravascular blood radioactivity in brain. Telmisartan penetrated into the brain little but enough to block AT(1)R and showed a consistently increasing brain/plasma ratio within the PET scanning period, suggesting slow clearance of the compound from the brain compared to the plasma clearance. Brain/plasma ratios at 30, 60, and 90min were 0.06, 0.13, and 0.18, respectively. No marked localization according to the AT(1)R distribution was noted over the entire brain, even on tracer alone dosing. Telmisartan penetrated into the brain enough to block AT(1)R and showed a slow clearance from the brain in conscious rhesus macaques, supporting the long-acting and central responses of telmisartan as a unique property among ARBs. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Atmospheric plume progression as a function of time and distance from the release point for radioactive isotopes.

    PubMed

    Eslinger, Paul W; Bowyer, Ted W; Cameron, Ian M; Hayes, James C; Miley, Harry S

    2015-10-01

    The radionuclide network of the International Monitoring System comprises up to 80 stations around the world that have aerosol and xenon monitoring systems designed to detect releases of radioactive materials to the atmosphere from nuclear explosions. A rule of thumb description of plume concentration and duration versus time and distance from the release point is useful when designing and deploying new sample collection systems. This paper uses plume development from atmospheric transport modeling to provide a power-law rule describing atmospheric dilution factors as a function of distance from the release point. Consider the plume center-line concentration seen by a ground-level sampler as a function of time based on a short-duration ground-level release of a nondepositing radioactive tracer. The concentration C (Bq m(-3)) near the ground varies with distance from the source with the relationship C=R×A(D,C) ×e (-λ(-1.552+0.0405×D)) × 5.37×10(-8) × D(-2.35) where R is the release magnitude (Bq), D is the separation distance (km) from the ground level release to the measurement location, λ is the decay constant (h(-1)) for the radionuclide of interest and AD,C is an attenuation factor that depends on the length of the sample collection period. This relationship is based on the median concentration for 10 release locations with different geographic characteristics and 365 days of releases at each location, and it has an R(2) of 0.99 for 32 distances from 100 to 3000 km. In addition, 90 percent of the modeled plumes fall within approximately one order of magnitude of this curve for all distances. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Investigation of radionuclides and anthropic tracer migration in groundwater at the Chernobyl site

    NASA Astrophysics Data System (ADS)

    Le Gal La Salle, Corinnne; Simonucci, Caroline; Roux, Céline; Bugai, Dmitry; Aquilina, Luc; Fourré, Elise; Jean-Baptiste, Philippe; Labasque, Thierry; Michelot, Jean-Luc; Fifield, Keith; Team Aster Team; Van Meir, Nathalie; Kashparov, Valeriy; Diez, Olivier; Bassot, Sylvain; Lancelot, Joel

    2013-04-01

    Following the reactor 4 explosion of the Chernobyl Nuclear Power Plant (ChNPP), at least 1019 Bq of radionuclides (RN) were released in the environment. In order to protect workers and prevent further atmospheric RN dispersion in the area adjacent to the ChNPP, contaminated wastes including fuel particles, topsoil layer and forest remains were buried in approximately 800 shallow trenches in the sand formation in the Red Forest waste dump site [1]. No containment measures were taken, and since then RN have leaked to the unsaturated zone and to the groundwater. Since 1999, migration of RN in the vicinity of the trench 22 at Red Forest site has been investigated within the frame of the EPIC program carried out by IRSN in collaboration with UIAR and IGS [2, 3]. A plume of 90Sr was shown downgradient from the trench 22 with activites reaching 3750 Bq/L [2]. In 2008, further studies were initiated through the TRASSE research group, based on a collaboration between IRSN and CNRS. These programs aim at combining groundwater dating with RN migration monitoring studies in order to constrain RN transport models [3]. Groundwater residence time was investigated based on 3H/He and CFC. Both tracers led to ages ranging from modern (1-3 y) at 2 m depth below the groundwater table to significantly higher apparent ages of 50-60 y at 27 m below the groundwater table [3]. 36Cl/Cl ratios 2 to 4 orders of magnitude higher than the theoretical natural ratio are measured in groundwater. Similarly, SF6 shows concentrations as high as 1200 pptv while natural concentrations are in the order of 6-7 pptv. Based on apparent groundwater ages, both contaminations are linked to the Chernobyl explosion. Hence those tracers show excellent potential to constrain conservative and reactive transport, respectively. In contrast, 238U/235U ratio down gradient from trench 22 remains similar to the natural ratio. This suggests that either most of the U contained in the trench is in a non soluble form, associated with U-Zr matrix fuel particles [5] and/or that migration of U is limited due to redox processes and/or microbial activity. The above described experience of post-Chernobyl studies shows that a combined analysis of radionuclides, natural and anthropogenic tracers provides an efficient research tool to better understand and quantify contaminant transport processes in the geo-sphere. Similar approaches can be applied to the study transport of RN in the subsurface, issued from both, diffuse (contaminated watersheds) and point (damaged NPP and fuel storage units) radioactive sources produced by the Fukushima accident. References [1] Dzhepo S. P., Skalskyy A., 2002, In Chernobyl disaster and groundwater, Shestopalov, V., Ed. A.A. Balkema: Lisse, pp 25-70. [2] Dewiere L., Bugai D. et al., 2004, J. Environ. Radioactiv., 74, (1-3), 139-150. [3] Van Meir N., Bugaï, et al., 2009, in: Oughton, D.H., Kashparov, V. (Eds.), Radioactive Particles in the Environment. Springer Science+Business Media B.V., pp.197-208. [4] Le Gal La Salle C., Aquilina L., et al., 2012, Appl. Geochem., 27 1304-1319. [5] Kashparov V.A., Ahamdach N., et. al., 2004, J. Environ. Radioactiv., 72, 335-353.

  11. Turnover of Phosphatidic Acid and Sodium Extrusion from Mammalian Erythrocytes

    PubMed Central

    Kirschner, Leonard B.; Barker, Jennifer

    1964-01-01

    Phosphatidic acid (PA) from swine and beef RBCs was isolated by chromatography on silicic acid columns. It comprised about 1 per cent of the total lipid phosphate in RBCs, but was eluted nearly pure from columns. An uncharacterized inositide accounted for 5 to 10 per cent of the phosphate in the PA-containing fraction. When cells were incubated with HP32O4 =, the fraction containing PA became more radioactive than any of the other fractions obtained. However, analysis of the labeled material by paper chromatography showed that most of the P32 was in the inositide, not in PA. With the assumption of kinetic homogeneity for cellular PA, compartmental analysis of the kinetics of tracer incorporation showed that PA turnover is 3 to 4 orders of magnitude too slow to account for sodium extrusion by these cells. PMID:14192545

  12. Nuclear medicine and imaging research (instrumentation and quantitative methods of evaluation): Comprehensive 3-year progress report for the period January 15, 1986-January 14, 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beck, R.N.; Cooper, M.D.

    1988-06-01

    This program addresses the problems involving the basic science and technology underlying the physical and conceptual tools of radioactive tracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The overall objective of this program is to further the development and transfer of radiotracer methodology from basic theory to routine clinical practice in order that individual patients and society as a whole will receive the maximum net benefit from the new knowledge gained. The focus of the research is on the development ofmore » new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility. 58 refs., 15 figs., 4 tabs.« less

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swarup, S.; Chatterjea, J.B.; Hosain, P.

    Several Hb. E-thalassemia and a few other cases of hematological interest were subjected to radio-iron tests using tracer doses of only 0.035 plus or minus 0.005 mu c/kg. of bodyweight and gas-flow counter for assaying the radio-activity of the samples. Serum iron and hemoglobin iron concentrations; curves for plasma iron clearance and appearance of radio-iron in red cells, and the plasma iron and the red cell iron turnover rates were obtained by standard methods. The results showed an increased rate of plasma clearance but decreased utilization of iron by erythrocytes in Hb. E-thalassemia disease; plasma iron-clearance pattern was similar tomore » iron deficiency anemia but the red cell radio-iron uptake pattern bore similarity to aplastic anemia. This suggests that ineffective erythropoiesis contributes significantly to the causation of anemia in Hb. E-thalassemia disease. (auth)« less

  14. A role for glucose in hypothermic hamsters

    NASA Technical Reports Server (NTRS)

    Resch, G. E.; Musacchia, X. J.

    1976-01-01

    Hypothermic hamsters at a rectal temperature of 7 C showed a fivefold increase in survival times from 20 to 100.5 hr when infused with glucose which maintained a blood level at about 45 mg/100 ml. A potential role for osmotic effects of the infusion was tested and eliminated. There was no improvement in survival of 3-O-methylglucose or dextran 40-infused animals. The fact that death eventually occurs even in the glucose-infused animal after about 4 days and that oxygen consumption undergoes a slow decrement in that period suggests that hypothermic survival is not wholly substrate limited. Radioactive tracer showed that localization of the C-14 was greatest in brain tissue and diaphragm, intermediate in heart and kidney, and lowest in skeletal muscle and liver. The significance of the label at sites important to respiration and circulation was presented.

  15. Human radiation studies: Remembering the early years. Oral history of Oncologist Helen Vodopick, M.D., December 28, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-08-01

    This report is a transcript of an interview with Dr. Helen Vodopick by representatives of the US DOE Office of Human Radiation Experiments. Dr. Vodopick was chosen for this interview because of her involvement with the Oak Ridge Institute of Nuclear Studies (ORINS) and Oak Ridge Associated Universities (ORAU) experimental cancer-therapy program involving total-body irradiation. After a short biographical sketch Dr. Vodopick relates her remembrances of the Medium-Exposure-Rate Total Body Irradiator (METBI), ORINS radioisotope tracer studies, treatment of cancer patients with the METBI, radiation treatment for leukemia patients, bone marrow treatment of leukemia, the Low-Exposure-Rate Total Body Irradiation (LETBI), treatmentmore » of radiation accident victims at ORAU, research with radioactive phosphorus and sulfur, and public opinion issues.« less

  16. Stretching of passive tracers and implications for mantle mixing

    NASA Astrophysics Data System (ADS)

    Conjeepuram, N.; Kellogg, L. H.

    2007-12-01

    Mid ocean ridge basalts(MORB) and ocean island basalts(OIB) have fundamentally different geochemical signatures. Understanding this difference requires a fundamental knowledge of the mixing processes that led to their formation. Quantitative methods used to assess mixing include examining the distribution of passive tracers, attaching time-evolution information to simulate decay of radioactive isotopes, and, for chaotic flows, calculating the Lyapunov exponent, which characterizes whether two nearby particles diverge at an exponential rate. Although effective, these methods are indirect measures of the two fundamental processes associated with mixing namely, stretching and folding. Building on work done by Kellogg and Turcotte, we present a method to compute the stretching and thinning of a passive, ellipsoidal tracer in three orthogonal directions in isoviscous, incompressible three dimensional flows. We also compute the Lyapunov exponents associated with the given system based on the quantitative measures of stretching and thinning. We test our method with two analytical and three numerical flow fields which exhibit Lagrangian turbulence. The ABC and STF class of analytical flows are a three and two parameter class of flows respectively and have been well studied for fast dynamo action. Since they generate both periodic and chaotic particle paths depending either on the starting point or on the choice of the parameters, they provide a good foundation to understand mixing. The numerical flow fields are similar to the geometries used by Ferrachat and Ricard (1998) and emulate a ridge - transform system. We also compute the stable and unstable manifolds associated with the numerical flow fields to illustrate the directions of rapid and slow mixing. We find that stretching in chaotic flow fields is significantly more effective than regular or periodic flow fields. Consequently, chaotic mixing is far more efficient than regular mixing. We also find that in the numerical flow field, there is a fundamental topological difference in the regions exhibiting slow or regular mixing for different model geometries.

  17. Production of recombinant human beta2-microglobulin for scintigraphic diagnosis of amyloidosis in uremia and hemodialysis.

    PubMed

    Linke, R P; Schäeffer, J; Gielow, P; Lindner, P; Lottspeich, F; Plückthun, A; Weiss, E H

    2000-02-01

    Amyloid of beta2-microglobulin (beta2m) origin can be diagnosed using 131I-radiolabelled-beta2m scintigraphy in patients with uremia and hemodialysis treatment. As the tracer beta2m is isolated from another patient, it carries the common risks, including viral infections such as Hepatitis B, C and HIV, which are associated with human plasma products. In order to exclude these risks we have produced recombinant human beta2m (rhbeta2m) in Escherichia coli. The expression vector pASK40DeltaLbeta2m(His)5 contains a C-terminal (His)5-tag for purification via immobilized metal ion affinity chromatography (IMAC). Size exclusion chromatography on a Superose 12 column represents the second step of purification. The isolated rhbeta2mH5 reacted in an immunochemically identical manner to native human beta2m, and showed a single band of approximately 11.8 kDa in Western blot analysis and revealed a single spot in two-dimensional gel electrophoresis. Mass spectrometry analysis revealed a single peak at the expected molecular mass of 12 415.8 Da. Uniformity was further proven by crystallization and N-terminal amino-acid sequence analysis. The rhbeta2mH5 protein was then produced under conditions that allow the intravenous use in humans. Intraveneously applied indium-111-labelled rhbeta2mH5 was monitored in hemodialysed patients with and without known beta2m-amyloidosis. The tracer was localized specifically to particular areas known to contain amyloid. Thus, this rhbeta2mH5 preparation is suitable for detecting amyloid-containing organs of the beta2m-class in vivo and fulfils the requirements of a tracer for common use. Finally, the use of indium-111 instead of iodine-131 has reduced the radioactive load and resulted in higher resolution.

  18. Evaluation of [(11)C]methyl-losartan and [(11)C]methyl-EXP3174 for PET imaging of renal AT1receptor in rats.

    PubMed

    Ismail, Basma; Hadizad, Tayebeh; Antoun, Rawad; Lortie, Mireille; deKemp, Robert A; Beanlands, Rob S B; DaSilva, Jean N

    2015-11-01

    The angiotensin II type 1 receptor (AT1R) is responsible for the main effects of the renin-angiotensin system (RAS), and its expression pattern is altered in several diseases. The [(11)C]methylated derivatives of the clinically used AT1R blocker (ARB) losartan and its active metabolite EXP3174, that binds with higher affinity to AT1R, were evaluated as potential PET imaging tracers in rat kidneys. [(11)C]Methyl-losartan and [(11)C]methyl-EXP3174 were synthesized by [(11)C]methylation of the tetrazole-protected analogs using [11C]methyl iodide. Tissue uptake and binding selectivity of [(11)C]methyl-losartan were assessed by ex-vivo biodistribution and in-vitro autoradiography. Radiolabeled metabolites in rat plasma and kidneys were analysed by column-switch HPLC. Both tracers were evaluated with small animal PET imaging. Due to better pharmacokinetics, [(11)C]methyl-EXP3174 was further investigated via PET by co-injection with AT1R antagonist candesartan or the AT2R antagonist PD123,319. Binding selectivity to renal AT1 over AT2 and Mas receptors was demonstrated for [(11)C]methyl-losartan. Plasma metabolite analysis at 10 min revealed stability of [(11)C]methyl-losartan and [(11)C]methyl-EXP3174 with the presence of unchanged tracer at 70.8 ± 9.9% and 81.4 ± 6.0%, of total radioactivity, respectively. Contrary to [(11)C]methyl-losartan, co-injection of candesartan with [(11)C]methyl-EXP3174 reduced the proportion of unchanged tracer (but not metabolites), indicating that these metabolites do not bind to AT1R in rat kidneys. MicroPET images for both radiotracers displayed high kidney-to-background contrast. Candesartan significantly reduced [(11)C]methyl-EXP3174 uptake in the kidney, whereas no difference was observed following PD123,319 indicating binding selectivity for AT1R. [(11)C]Methyl-EXP3174 displayed a favorable binding profile compared to [(11)C]methyl-losartan for imaging renal AT1Rs supporting further studies to assess its full potential as a quantitative probe for AT1R via PET. Copyright © 2015. Published by Elsevier Inc.

  19. HPLC and TLC methods for analysis of [18F]FDG and its metabolites from biological samples.

    PubMed

    Rokka, Johanna; Grönroos, Tove J; Viljanen, Tapio; Solin, Olof; Haaparanta-Solin, Merja

    2017-03-24

    The most used positron emission tomography (PET) tracer, 2-[ 18 F]fluoro-2-deoxy-d-glucose ([ 18 F]FDG), is a glucose analogue that is used to measure tissue glucose consumption. Traditionally, the Sokoloff model is the basis for [ 18 F]FDG modeling. According to this model, [ 18 F]FDG is expected to be trapped in a cell in the form of [ 18 F]FDG-6-phosphate ([ 18 F]FDG-6-P). However, several studies have shown that in tissues, [ 18 F]FDG metabolism goes beyond [ 18 F]FDG-6-P. Our aim was to develop radioHPLC and radioTLC methods for analysis of [ 18 F]FDG metabolites from tissue samples. The radioHPLC method uses a sensitive on-line scintillation detector to detect radioactivity, and the radioTLC method employs digital autoradiography to detect the radioactivity distribution on a TLC plate. The HPLC and TLC methods were developed using enzymatically in vitro-produced metabolites of [ 18 F]FDG as reference standards. For this purpose, three [ 18 F]FDG metabolites were synthesized: [ 18 F]FDG-6-P, [ 18 F]FD-PGL, and [ 18 F]FDG-1,6-P2. The two methods were evaluated by analyzing the [ 18 F]FDG metabolic profile from rodent ex vivo tissue homogenates. The HPLC method with an on-line scintillation detector had a wide linearity in a range of 5Bq-5kBq (LOD 46Bq, LOQ 139Bq) and a good resolution (Rs ≥1.9), and separated [ 18 F]FDG and its metabolites clearly. The TLC method combined with digital autoradiography had a high sensitivity in a wide range of radioactivity (0.1Bq-2kBq, LOD 0.24Bq, LOQ 0.31Bq), and multiple samples could be analyzed simultaneously. As our test and the method validation with ex vivo samples showed, both methods are useful, and at best they complement each other in analysis of [ 18 F]FDG and its radioactive metabolites from biological samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. High Contrast PET Imaging of GRPR Expression in Prostate Cancer Using Cobalt-Labeled Bombesin Antagonist RM26

    PubMed Central

    Thisgaard, Helge; Rosenström, Ulrika; Dam, Johan Hygum; Larhed, Mats

    2017-01-01

    High gastrin releasing peptide receptor (GRPR) expression is associated with numerous cancers including prostate and breast cancer. The aim of the current study was to develop a 55Co-labeled PET agent based on GRPR antagonist RM26 for visualization of GRPR-expressing tumors. Labeling with 57Co and 55Co, stability, binding specificity, and in vitro and in vivo characteristics of 57Co-NOTA-PEG2-RM26 were studied. NOTA-PEG2-RM26 was successfully radiolabeled with 57Co and 55Co with high yields and demonstrated high stability. The radiopeptide showed retained binding specificity to GRPR in vitro and in vivo. 57Co-NOTA-PEG2-RM26 biodistribution in mice was characterized by rapid clearance of radioactivity from blood and normal non-GRPR-expressing organs and low hepatic uptake. The clearance was predominantly renal with a low degree of radioactivity reabsorption. Tumor-to-blood ratios were approximately 200 (3 h pi) and 1000 (24 h pi). The favorable biodistribution of cobalt-labeled NOTA-PEG2-RM26 translated into high contrast preclinical PET/CT (using 55Co) and SPECT/CT (using 57Co) images of PC-3 xenografts. The initial biological results suggest that 55Co-NOTA-PEG2-RM26 is a promising tracer for PET visualization of GRPR-expressing tumors. PMID:29097932

  1. Glucocorticoid regulation in rat brain cell cultures. Hydrocortisone increases the rate of synthesis of glycerol phosphate dehydrogenase in C6 glioma cells. [Tritium tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGinnis, J.F.; de Vellis, J.

    Cytoplasmic glycerol phosphate dehydrogenase (sn-glycerol-3-phosphate: NAD/sup +/ 2-oxidoreductase, EC 1.1.1.8) was rapidly purified from rat skeletal muscle in high yield using a combination of classical and affinity techniques. A single band of protein having a molecular weight of 30,000 was found using dodecyl sulfate-polyacrylamide gel electrophoresis. Antisera were generated in rabbits against the purified enzyme and demonstrated to be monospecific by Ouchterlony immunodiffusion against crude homogenates from hydrocortisone-induced and uninduced C6 cells. All of the radioactivity in immunoprecipitates from (/sup 3/H)leucine-labeled cells co-migrated with purified glycerol phosphate dehydrogenase. The amount of radioactivity precipitated was directly proportional to the amount ofmore » labeled glycerol phosphate dehydrogenase present, indicating that the assay could be used to quantitate newly synthesized glycerol phosphate dehydrogenase molecules. Using these techniques, the induction of glycerol phosphate dehydrogenase activity by hydrocortisone in the C6 glioma cell line was shown to be due to an increase in the rate of synthesis of the enzyme. Analysis of the kinetics of induction and deinduction supports the above conclusion and suggests that there is essentially no change in the rate of degradation of glycerol phosphate dehydrogenase in the presence and absence of hormone.« less

  2. Selective 2-( sup 18 F)fluorodopa uptake for melanogenesis in murine metastatic melanomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishiwata, K.; Kubota, K.; Kubota, R.

    The relationship between 3,4-dihydroxy-2-({sup 18}F)fluoro-L-phenylalanine (2-({sup 18}F)FDOPA) uptake and melanogenesis was studied using mice bearing two B16 melanomas: B16-F1 has a higher melanin synthesis ability and a slower growing rate than the higher metastatic B16-F10. A significantly higher 2-({sup 18}F)FDOPA uptake by B16-F1 than by B16-F10 and a reverse relationship for the uptake of ({sup 14}C) 2-deoxy-2-fluoro-D-glucose and ({sup 3}H)thymidine were observed 1 hr postinjection. F1-to-F10 ratios of both the 2-({sup 18}F)FDOPA uptake and the acid-insoluble radioactivity increased to about 5 at 6 hr, which paralleled the melanin content. FM3A mammary carcinoma showed a 2-({sup 18}F)FDOPA uptake similar to themore » B16-F10 but without the acid-insoluble radioactivity. With D,L-DOPA loading, a 55% decreased uptake by FM3A 1 hr postinjection was significantly greater than the 20% reduction in both melanomas. O-Methylated 2-({sup 18}F)FDOPA was a predominant acid-soluble metabolite in all tumors. Whole-body autoradiography discriminated the two melanomas clearly. 2-({sup 18}F)FDOPA may be a promising tracer for the selective imaging of melanogenesis.« less

  3. Blind identification of the kinetic parameters in three-compartment models

    NASA Astrophysics Data System (ADS)

    Riabkov, Dmitri Y.; Di Bella, Edward V. R.

    2004-03-01

    Quantified knowledge of tissue kinetic parameters in the regions of the brain and other organs can offer information useful in clinical and research applications. Dynamic medical imaging with injection of radioactive or paramagnetic tracer can be used for this measurement. The kinetics of some widely used tracers such as [18F]2-fluoro-2-deoxy-D-glucose can be described by a three-compartment physiological model. The kinetic parameters of the tissue can be estimated from dynamically acquired images. Feasibility of estimation by blind identification, which does not require knowledge of the blood input, is considered analytically and numerically in this work for the three-compartment type of tissue response. The non-uniqueness of the two-region case for blind identification of kinetic parameters in three-compartment model is shown; at least three regions are needed for the blind identification to be unique. Numerical results for the accuracy of these blind identification methods in different conditions were considered. Both a separable variables least-squares (SLS) approach and an eigenvector-based algorithm for multichannel blind deconvolution approach were used. The latter showed poor accuracy. Modifications for non-uniform time sampling were also developed. Also, another method which uses a model for the blood input was compared. Results for the macroparameter K, which reflects the metabolic rate of glucose usage, using three regions with noise showed comparable accuracy for the separable variables least squares method and for the input model-based method, and slightly worse accuracy for SLS with the non-uniform sampling modification.

  4. A preliminary study of the effect of guaiphenesin on mucociliary clearance from the human lung

    PubMed Central

    Thomson, M. L.; Pavia, D.; McNicol, M. W.

    1973-01-01

    Thomson, M. L., Pavia, D., and McNicol, M. W. (1973).Thorax, 28, 742-747. A preliminary study of the effect of guaiphenesin on mucociliary clearance from the human lung. The effect of guaiphenesin (administered as Robitussin1) on mucociliary clearance has been assessed in 15 subjects from the rate of removal from the lung of previously inhaled radioactive tracer particles. The guaiphenesin was compared with a positive control preparation consisting of the guaiphenesin vehicle only in two double-blind crossover trials. The first trial examined eight aged `healthy' volunteer subjects and the second trial examined seven chronic bronchitic patients. Sequential gamma counts were made from the whole lung by scintillation counters for 6 hours after inhalation and the chest was also scanned rectilinearly. In the first 5 hours after inhalation the mean rate of removal of particles and therefore of secretions was faster after guaiphenesin than after the control preparation. This difference was not statistically significant in the healthy volunteers but achieved significance (P <0·05) in the chronic bronchitic patients. Lung scans after inhaling the tracer aerosol indicated that on average the initial penetration of the particles into the lung was similar in the guaiphenesin and control runs. The faster clearance after guaiphenesin was unlikely to be due to bulk movements of mucus caused by coughing since the mean frequency of coughing during the experiment was somewhat less after the drug. PMID:4595814

  5. Optimizing detection of noble gas emission at a former UNE site: sample strategy, collection, and analysis

    NASA Astrophysics Data System (ADS)

    Kirkham, R.; Olsen, K.; Hayes, J. C.; Emer, D. F.

    2013-12-01

    Underground nuclear tests may be first detected by seismic or air samplers operated by the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization). After initial detection of a suspicious event, member nations may call for an On-Site Inspection (OSI) that in part, will sample for localized releases of radioactive noble gases and particles. Although much of the commercially available equipment and methods used for surface and subsurface environmental sampling of gases can be used for an OSI scenario, on-site sampling conditions, required sampling volumes and establishment of background concentrations of noble gases require development of specialized methodologies. To facilitate development of sampling equipment and methodologies that address OSI sampling volume and detection objectives, and to collect information required for model development, a field test site was created at a former underground nuclear explosion site located in welded volcanic tuff. A mixture of SF-6, Xe127 and Ar37 was metered into 4400 m3 of air as it was injected into the top region of the UNE cavity. These tracers were expected to move towards the surface primarily in response to barometric pumping or through delayed cavity pressurization (accelerated transport to minimize source decay time). Sampling approaches compared during the field exercise included sampling at the soil surface, inside surface fractures, and at soil vapor extraction points at depths down to 2 m. Effectiveness of various sampling approaches and the results of tracer gas measurements will be presented.

  6. User`s guide for UTCHEM-5.32m a three dimensional chemical flood simulator. Final report, September 30, 1992--December 31, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-07-01

    UTCHEM is a three-dimensional chemical flooding simulator. The solution scheme is analogous to IMPES, where pressure is solved for implicitly, but concentrations rather than saturations are then solved for explicitly. Phase saturations and concentrations are then solved in a flash routine. An energy balance equation is solved explicitly for reservoir temperature. The energy balance equation includes heat flow between the reservoir and the over-and under-burden rocks. The major physical phenomena modeled in the simulator are: dispersion; dilution effects; adsorption; interfacial tension; relative permeability; capillary trapping; cation exchange; phase density; compositional phase viscosity; phase behavior (pseudoquaternary); aqueous reactions; partitioning of chemicalmore » species between oil and water; dissolution/precipitation; cation exchange reactions involving more than two cations; in-situ generation of surfactant from acidic crude oil; pH dependent adsorption; polymer properties: shear thinning viscosity; inaccessible pore volume; permeability reduction; adsorption; gel properties: viscosity; permeability reduction; adsorption; tracer properties: partitioning; adsorption; radioactive decay; reaction (ester hydrolization); temperature dependent properties: viscosity; tracer reaction; gel reactions The following options are available with UTCHEM: isothermal or non-isothermal conditions, a constant or variable time-step, constant pressure or constant rate well conditions, horizontal and vertical wells, and a radial or Cartesian geometry. Please refer to the dissertation {open_quotes}Field Scale Simulation of Chemical Flooding{close_quotes} by Naji Saad, August, 1989, for a more detailed discussion of the UTCHEM simulator and its formulation.« less

  7. Parallel labeling experiments and metabolic flux analysis: Past, present and future methodologies.

    PubMed

    Crown, Scott B; Antoniewicz, Maciek R

    2013-03-01

    Radioactive and stable isotopes have been applied for decades to elucidate metabolic pathways and quantify carbon flow in cellular systems using mass and isotope balancing approaches. Isotope-labeling experiments can be conducted as a single tracer experiment, or as parallel labeling experiments. In the latter case, several experiments are performed under identical conditions except for the choice of substrate labeling. In this review, we highlight robust approaches for probing metabolism and addressing metabolically related questions though parallel labeling experiments. In the first part, we provide a brief historical perspective on parallel labeling experiments, from the early metabolic studies when radioisotopes were predominant to present-day applications based on stable-isotopes. We also elaborate on important technical and theoretical advances that have facilitated the transition from radioisotopes to stable-isotopes. In the second part of the review, we focus on parallel labeling experiments for (13)C-metabolic flux analysis ((13)C-MFA). Parallel experiments offer several advantages that include: tailoring experiments to resolve specific fluxes with high precision; reducing the length of labeling experiments by introducing multiple entry-points of isotopes; validating biochemical network models; and improving the performance of (13)C-MFA in systems where the number of measurements is limited. We conclude by discussing some challenges facing the use of parallel labeling experiments for (13)C-MFA and highlight the need to address issues related to biological variability, data integration, and rational tracer selection. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. A preliminary assessment on the use of biochar as a soil additive for reducing soil-to-plant uptake of cesium isotopes in radioactively contaminated environments

    DOE PAGES

    Hamilton, Terry F.; Martinelli, Roger E.; Kehl, Steven R.; ...

    2015-10-19

    A series of K d tracer batch experiments were conducted in this paper to assess the absorptive-desorption properties of Biochar as a potential agent to selectively sequester labile soil Cs or otherwise help reduce the uptake of Cs isotopes into plants. A parallel experiment was conducted for strontium. Fine-grained fractionated Woodlands tree Biochar was found to have a relatively high affinity for Cs ions (K d > 100) relative to coral soil (K d < 10) collected from the Marshall Islands. The Biochar material also contains an abundance of K (and Mg). Finally, these findings support a hypothesis that themore » addition of Biochar as a soil amendment may provide a simple yet effective method for reducing soil-to-plant transfer of Cs isotopes in contaminated environments.« less

  9. Effects of ionizing radiation upon natural populations and ecosystems. Final report. [Ecological perspectives in land use planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCormick, J.F.

    Accomplishments throughout a 10-year period summarized include: a study of the effects of radiation from a ..gamma.. source on the ecology of the El Verde rain forest in Puerto Rico, with emphasis on the role of secondary succession in the recovery of forest ecosystems following irradiation; the effects of light and temperature on gaseous exchange in trees using /sup 14/CO/sub 2/ as a tracer in Palcourea; the nature of the sensitivity of pine trees to ionizing radiation and the possible synergistic effects of elevated ozone levels on radiosensitivity; the combined effects of radioactive and thermal effluents on plant communities ofmore » a swamp hardwood forest; and the development of a new conceptual approach to the evaluation of environmental quality, with emphasis on ecological perspectives in land use planning. (CH)« less

  10. Positron emission particle tracking using a modular positron camera

    NASA Astrophysics Data System (ADS)

    Parker, D. J.; Leadbeater, T. W.; Fan, X.; Hausard, M. N.; Ingram, A.; Yang, Z.

    2009-06-01

    The technique of positron emission particle tracking (PEPT), developed at Birmingham in the early 1990s, enables a radioactively labelled tracer particle to be accurately tracked as it moves between the detectors of a "positron camera". In 1999 the original Birmingham positron camera, which consisted of a pair of MWPCs, was replaced by a system comprising two NaI(Tl) gamma camera heads operating in coincidence. This system has been successfully used for PEPT studies of a wide range of granular and fluid flow processes. More recently a modular positron camera has been developed using a number of the bismuth germanate (BGO) block detectors from standard PET scanners (CTI ECAT 930 and 950 series). This camera has flexible geometry, is transportable, and is capable of delivering high data rates. This paper presents simple models of its performance, and initial experience of its use in a range of geometries and applications.

  11. [Anaphylactic shock due to patent blue: four case report and review of literature].

    PubMed

    Lucas, N; Interne, S Benay; Laine, P; Nicolie, B; Fondrinier, E

    2010-04-01

    Description of four cases of anaphylactic shock with blue dye injection (bleu patenté V Guerbet 2.5%) during sentinel node biopsy for breast cancer. Women with breast carcinoma and combined approach with radioactive tracer and blue patent injection. Four cases were observed, which means an incidence of 0.57%. We report one case of grade II anaphylactic reaction and three cases of grade III requiring active reanimation and adrenaline perfusion. One patient developed a pulmonary embolism during the postoperative period, but no death was observed. We find an incidence of 1.06% of allergy but only 0.25% of anaphylactic shock (grade III). These rare but serious cases must weigh up the benefits and risks of using blue dye. We suggest using blue dye injection only in case of radioisotope detection failure. Of course, this approach must be evaluated. (c) 2009 Elsevier Masson SAS. All rights reserved.

  12. Effect of platelet activating factor on endothelial permeability to plasma macromolecules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Handley, D.A.; Arbeeny, C.M.; Lee, M.L.

    The effect of intrajugular administration of platelet activating factor (PAF-C16) on vascular permeability was examined in the guinea pig. To examine the loss of selective endothelial permeability, the extravasative effect of PAF was assessed by monitoring hemoconcentration and the plasma loss of /sup 125/I-albumin (6.7 nm), /sup 125/I-low density lipoproteins (22.0 nm) or /sup 125/I-very low density lipoproteins (62.1 nm). Extravasation was dose-dependent and began 1 min after PAF administration, continuing for 5-7 min. During extravasation, there was no evidence for selective plasma retention of any of the labeled plasma tracers, as measured by plasma radioactivity. These results suggest thatmore » PAF-induced extravasation is dose-dependent, with increases in vascular permeability sufficient to permit similar plasma efflux rates of albumin, low density lipoproteins and very low density lipoproteins.« less

  13. Biomedical research applications of electromagnetically separated enriched stable isotopes

    NASA Astrophysics Data System (ADS)

    Lambrecht, R. M.

    The current and projected annual requirements through 1985 for stable isotopes enriched by electromagnetic separation methods were reviewed for applications in various types of biomedical research: (1) medical radiosiotope production, labeled compounds, and potential radio-pharmaceuticals; (2) nutrition, food science, and pharmacology: (3) metallobiochemistry and environmental toxicology; (4) nuclear magnetic resonance, electron paramagnetic resonance, and moessbauer spectroscopy in biochemical, biophysical, and biomedical research; and (5) miscellaneous advances in radioactive and nonradioactive tracer technology. Radioisotopes available from commercial sources or routinely used in clinical nuclear medicine were excluded. Current requirements for enriched stable isotopes in biomedical research are not being satisfied. Severe shortages exist for Mg 26, Ca 43, Zn 70, Se 76, Se 77, Se 78, Pd 102, Cd 111, Cd 113, and Os 190. Many interesting and potentially important investigations in biomedical research require small quantities of specific elements at high isotopic enrichments.

  14. In vivo nanoparticle-mediated radiopharmaceutical-excited fluorescence molecular imaging

    PubMed Central

    Hu, Zhenhua; Qu, Yawei; Wang, Kun; Zhang, Xiaojun; Zha, Jiali; Song, Tianming; Bao, Chengpeng; Liu, Haixiao; Wang, Zhongliang; Wang, Jing; Liu, Zhongyu; Liu, Haifeng; Tian, Jie

    2015-01-01

    Cerenkov luminescence imaging utilizes visible photons emitted from radiopharmaceuticals to achieve in vivo optical molecular-derived signals. Since Cerenkov radiation is weak, non-optimum for tissue penetration and continuous regardless of biological interactions, it is challenging to detect this signal with a diagnostic dose. Therefore, it is challenging to achieve useful activated optical imaging for the acquisition of direct molecular information. Here we introduce a novel imaging strategy, which converts γ and Cerenkov radiation from radioisotopes into fluorescence through europium oxide nanoparticles. After a series of imaging studies, we demonstrate that this approach provides strong optical signals with high signal-to-background ratios, an ideal tissue penetration spectrum and activatable imaging ability. In comparison with present imaging techniques, it detects tumour lesions with low radioactive tracer uptake or small tumour lesions more effectively. We believe it will facilitate the development of nuclear and optical molecular imaging for new, highly sensitive imaging applications. PMID:26123615

  15. Increasing the Efficacy of SLNB in Cases of Malignant Melanoma Located in Close Proximity to the Lymphatic Basin

    PubMed Central

    Bogdanov-Berezovsky, Alexander; Pagkalos, Vasileios A.; Silberstein, Eldad; Xanthinaki, Arsinoi A.; Krieger, Yuval

    2014-01-01

    Background. Being predictive of the entire nodal bed, sentinel lymph node biopsy (SLNB) is invaluable in the surgical management of melanoma. Although the concept is simple, sentinel lymph node (SLN) identification and removal can be technically challenging. Methods. A total of 102 consecutive patients have undergone SLNB in the Division of Plastic and Reconstructive Surgery of Soroka University Medical Center from 2009 to 2012. Patients have undergone SLNB using a radioactive tracer and blue stain in order to identify the SLN. Although SLNB usually precedes the wide excision of melanoma, primary lesions in close proximity (<10 cm) to the lymph basin require wide excision before beginning the SLN quest. Results. All pathology reports confirmed the excision of lymph nodes. Conclusions. When treating MM in close proximity to the lymph basin, changing the sequence of the SLNB procedure seems to increase the efficacy of the method. PMID:24660067

  16. Experiments with the Kema cyclone incinerator for radioactive waste

    NASA Astrophysics Data System (ADS)

    Matteman, J. L.; Tigchelaar, P.

    A cyclone incinerator for the treatment of solid waste at a nuclear power station was developed to reduce volume and weight of the final waste; reductions by factors of 7 and 80 respectively are possible (after solidification). For burnable waste the throughput is 23 kg/hr for 6 hr runs. About 7000 kg of nonradioactive waste were treated in total. The behavior of potentially dangerous radionuclides (Co, Cs, Mn and Sr) was studied by tracers. It appears that Co, Mn and Sr are concentrated in the resulting ashes, where 55% of the Cs is also found; the remaining Cs is unaccounted for. The ashes were solidified by mixing them with concrete in a 1:1 ratio. Due to the flexibility of the facility, start-up and turn-down periods are short. Since the process can be controlled automatically, the operation can be run by one employee, to load the waste and handle the ashes.

  17. Effect of oxotremorine, physostigmine, and scopolamine on brain acetylcholine synthesis: a study using HPLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bertrand, N.; Beley, A.

    The synthesis rate of brain acetylcholine (ACh) was estimated in mice following i.v. administration of ({sup 3}H)choline (Ch). The measurements were performed 1 min after the tracer injection, using the ({sup 3}H)ACh/({sup 3}H)Ch specific radioactivity ratio as an index of ACh synthesis rate. Endogenous and labeled Ch and ACh were quantified using HPLC methodology. Oxotremorine and physostigmine (0.5 mg/kg, i.p.) increased the steady state concentration of brain ACh by + 130% and 84%, respectively and of Ch by + 60% (oxotremorine); they decreased ACh synthesis by 62 and 55%, respectively. By contrast, scopolamine (0.7 mg/kg, i.p.) decreased the cerebral contentmore » of Ch by - 26% and of ACh by - 23% without enhancing the synthesis of ACh. The results show the utility of HPLC methodology in the investigation of ACh turnover.« less

  18. Infra-red technique for cerebral blood flow: comparison with /sup 133/Xenon clearance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colacino, J.M.; Grubb, B.; Joebsis, F.F.

    A rapid infra-red optical technique has been developed for the measurement of cerebral blood flow. The method measures optical density changes across the intact skull during the passage of a bolus of the dye. Cardio-Green (CG). The clearance curves obtained for CG boluses are very short (less than 30 sec) in comparison with those obtained with tracers such as /sup 133/Xenon (10-30 min) that distribute into cerebral tissue. The volume of distribution of CG is totally intravascular, and the dye is relatively slowly cleared from the body. The important advantages of this spectrophotometric technique are its speed, versatility, and themore » avoidance of radioactive materials. The differential spectrophotometer used in this study, with trivial modifications, has been used to monitor changes in brain blood volume, oxygen saturation of hemoglobin, and cortical mitochondrial respiratory function, which illustrate the versatility of the technique for neurological assessments.« less

  19. Positron Emission Tomography of the Heart

    DOE R&D Accomplishments Database

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1979-01-01

    Positron emission computed tomography (PCT) represents an important new tool for the noninvasive evaluation and, more importantly, quantification of myocardial performance. Most currently available techniques permit assessment of only one aspect of cardiac function, i.e., myocardial perfusion by gamma scintillation camera imaging with Thallium-201 or left ventricular function by echocardiography or radionuclide angiocardiography. With PCT it may become possible to study all three major segments of myocardial performance, i.e., regional blood flow, mechanical function and, most importantly, myocardial metabolism. Each of these segments can either be evaluated separately or in combination. This report briefly describes the principles and technological advantages of the imaging device, reviews currently available radioactive tracers and how they can be employed for the assessment of flow, function and metabolism; and, lastly, discusses possible applications of PCT for the study of cardiac physiology or its potential role in the diagnosis of cardiac disease.

  20. PROCESSING OF RADIOACTIVE WASTE

    DOEpatents

    Allemann, R.T.; Johnson, B.M. Jr.

    1961-10-31

    A process for concentrating fission-product-containing waste solutions from fuel element processing is described. The process comprises the addition of sugar to the solution, preferably after it is made alkaline; spraying the solution into a heated space whereby a dry powder is formed; heating the powder to at least 220 deg C in the presence of oxygen whereby the powder ignites, the sugar is converted to carbon, and the salts are decomposed by the carbon; melting the powder at between 800 and 900 deg C; and cooling the melt. (AEC) antidiuretic hormone from the blood by the liver. Data are summarized from the following: tracer studies on cardiovascular functions; the determination of serum protein-bound iodine; urinary estrogen excretion in patients with arvanced metastatic mammary carcinoma; the relationship between alheroclerosis aad lipoproteins; the physical chemistry of lipoproteins; and factors that modify the effects of densely ionizing radia

  1. Orphan strontium-87 in abyssal peridotites: daddy was a granite.

    PubMed

    Snow, J E; Hart, S R; Dick, H J

    1993-12-17

    The (87)Sr/(86)Sr ratios in some bulk abyssal and alpine peridotites are too high to be binary mixtures of depleted mantle and seawater components. The apparent excess, or "orphan," (87)Sr appears to be separated from its radioactive parent. Such observations were widely held to be analytical artifacts. Study of several occurrences of orphan (87)Sr shows that the orphan component in abyssal peridotite is located in the alteration products of olivine and enstatite in the peridotite. The orphan (87)Sr is most likely introduced by infiltration of low-temperature (<200 degrees C) seawater bearing suspended detrital particulates. These particulates include grains of detrital clay that are partly derived from continental (that is, granitic) sources and thus are highly radiogenic. Orphan (87)Sr and other radiogenic isotopes may provide a tracer for low-temperature seawater penetrating into the oceanic crust.

  2. Orphan Strontium-87 in Abyssal Peridotites: Daddy Was a Granite

    NASA Astrophysics Data System (ADS)

    Snow, Jonathan E.; Hart, Stanley R.; Dick, Henry J. B.

    1993-12-01

    The 87Sr/86Sr ratios in some bulk abyssal and alpine peridotites are too high to be binary mixtures of depleted mantle and seawater components. The apparent excess, or "orphan," 87Sr appears to be separated from its radioactive parent. Such observations were widely held to be analytical artifacts. Study of several occurrences of orphan 87Sr shows that the orphan component in abyssal peridotite is located in the alteration products of olivine and enstatite in the peridotite. The orphan 87Sr is most likely introduced by infiltration of low-temperature (<200^circC) seawater bearing suspended detrital particulates. These particulates include grains of detrital clay that are partly derived from continental (that is, granitic) sources and thus are highly radiogenic. Orphan 87Sr and other radiogenic isotopes may provide a tracer for low-temperature seawater penetrating into the oceanic crust.

  3. Rapid Multi-Tracer PET Tumor Imaging With F-FDG and Secondary Shorter-Lived Tracers.

    PubMed

    Black, Noel F; McJames, Scott; Kadrmas, Dan J

    2009-10-01

    Rapid multi-tracer PET, where two to three PET tracers are rapidly scanned with staggered injections, can recover certain imaging measures for each tracer based on differences in tracer kinetics and decay. We previously showed that single-tracer imaging measures can be recovered to a certain extent from rapid dual-tracer (62)Cu - PTSM (blood flow) + (62)Cu - ATSM (hypoxia) tumor imaging. In this work, the feasibility of rapidly imaging (18)F-FDG plus one or two of these shorter-lived secondary tracers was evaluated in the same tumor model. Dynamic PET imaging was performed in four dogs with pre-existing tumors, and the raw scan data was combined to emulate 60 minute long dual- and triple-tracer scans, using the single-tracer scans as gold standards. The multi-tracer data were processed for static (SUV) and kinetic (K(1), K(net)) endpoints for each tracer, followed by linear regression analysis of multi-tracer versus single-tracer results. Static and quantitative dynamic imaging measures of FDG were both accurately recovered from the multi-tracer scans, closely matching the single-tracer FDG standards (R > 0.99). Quantitative blood flow information, as measured by PTSM K(1) and SUV, was also accurately recovered from the multi-tracer scans (R = 0.97). Recovery of ATSM kinetic parameters proved more difficult, though the ATSM SUV was reasonably well recovered (R = 0.92). We conclude that certain additional information from one to two shorter-lived PET tracers may be measured in a rapid multi-tracer scan alongside FDG without compromising the assessment of glucose metabolism. Such additional and complementary information has the potential to improve tumor characterization in vivo, warranting further investigation of rapid multi-tracer techniques.

  4. Rapid Multi-Tracer PET Tumor Imaging With 18F-FDG and Secondary Shorter-Lived Tracers

    PubMed Central

    Black, Noel F.; McJames, Scott; Kadrmas, Dan J.

    2009-01-01

    Rapid multi-tracer PET, where two to three PET tracers are rapidly scanned with staggered injections, can recover certain imaging measures for each tracer based on differences in tracer kinetics and decay. We previously showed that single-tracer imaging measures can be recovered to a certain extent from rapid dual-tracer 62Cu – PTSM (blood flow) + 62Cu — ATSM (hypoxia) tumor imaging. In this work, the feasibility of rapidly imaging 18F-FDG plus one or two of these shorter-lived secondary tracers was evaluated in the same tumor model. Dynamic PET imaging was performed in four dogs with pre-existing tumors, and the raw scan data was combined to emulate 60 minute long dual- and triple-tracer scans, using the single-tracer scans as gold standards. The multi-tracer data were processed for static (SUV) and kinetic (K1, Knet) endpoints for each tracer, followed by linear regression analysis of multi-tracer versus single-tracer results. Static and quantitative dynamic imaging measures of FDG were both accurately recovered from the multi-tracer scans, closely matching the single-tracer FDG standards (R > 0.99). Quantitative blood flow information, as measured by PTSM K1 and SUV, was also accurately recovered from the multi-tracer scans (R = 0.97). Recovery of ATSM kinetic parameters proved more difficult, though the ATSM SUV was reasonably well recovered (R = 0.92). We conclude that certain additional information from one to two shorter-lived PET tracers may be measured in a rapid multi-tracer scan alongside FDG without compromising the assessment of glucose metabolism. Such additional and complementary information has the potential to improve tumor characterization in vivo, warranting further investigation of rapid multi-tracer techniques. PMID:20046800

  5. Feasibility of Rapid Multitracer PET Tumor Imaging

    NASA Astrophysics Data System (ADS)

    Kadrmas, D. J.; Rust, T. C.

    2005-10-01

    Positron emission tomography (PET) can characterize different aspects of tumor physiology using various tracers. PET scans are usually performed using only one tracer since there is no explicit signal for distinguishing multiple tracers. We tested the feasibility of rapidly imaging multiple PET tracers using dynamic imaging techniques, where the signals from each tracer are separated based upon differences in tracer half-life, kinetics, and distribution. Time-activity curve populations for FDG, acetate, ATSM, and PTSM were simulated using appropriate compartment models, and noisy dual-tracer curves were computed by shifting and adding the single-tracer curves. Single-tracer components were then estimated from dual-tracer data using two methods: principal component analysis (PCA)-based fits of single-tracer components to multitracer data, and parallel multitracer compartment models estimating single-tracer rate parameters from multitracer time-activity curves. The PCA analysis found that there is information content present for separating multitracer data, and that tracer separability depends upon tracer kinetics, injection order and timing. Multitracer compartment modeling recovered rate parameters for individual tracers with good accuracy but somewhat higher statistical uncertainty than single-tracer results when the injection delay was >10 min. These approaches to processing rapid multitracer PET data may potentially provide a new tool for characterizing multiple aspects of tumor physiology in vivo.

  6. Multi-atlas attenuation correction supports full quantification of static and dynamic brain PET data in PET-MR

    NASA Astrophysics Data System (ADS)

    Mérida, Inés; Reilhac, Anthonin; Redouté, Jérôme; Heckemann, Rolf A.; Costes, Nicolas; Hammers, Alexander

    2017-04-01

    In simultaneous PET-MR, attenuation maps are not directly available. Essential for absolute radioactivity quantification, they need to be derived from MR or PET data to correct for gamma photon attenuation by the imaged object. We evaluate a multi-atlas attenuation correction method for brain imaging (MaxProb) on static [18F]FDG PET and, for the first time, on dynamic PET, using the serotoninergic tracer [18F]MPPF. A database of 40 MR/CT image pairs (atlases) was used. The MaxProb method synthesises subject-specific pseudo-CTs by registering each atlas to the target subject space. Atlas CT intensities are then fused via label propagation and majority voting. Here, we compared these pseudo-CTs with the real CTs in a leave-one-out design, contrasting the MaxProb approach with a simplified single-atlas method (SingleAtlas). We evaluated the impact of pseudo-CT accuracy on reconstructed PET images, compared to PET data reconstructed with real CT, at the regional and voxel levels for the following: radioactivity images; time-activity curves; and kinetic parameters (non-displaceable binding potential, BPND). On static [18F]FDG, the mean bias for MaxProb ranged between 0 and 1% for 73 out of 84 regions assessed, and exceptionally peaked at 2.5% for only one region. Statistical parametric map analysis of MaxProb-corrected PET data showed significant differences in less than 0.02% of the brain volume, whereas SingleAtlas-corrected data showed significant differences in 20% of the brain volume. On dynamic [18F]MPPF, most regional errors on BPND ranged from -1 to  +3% (maximum bias 5%) for the MaxProb method. With SingleAtlas, errors were larger and had higher variability in most regions. PET quantification bias increased over the duration of the dynamic scan for SingleAtlas, but not for MaxProb. We show that this effect is due to the interaction of the spatial tracer-distribution heterogeneity variation over time with the degree of accuracy of the attenuation maps. This work demonstrates that inaccuracies in attenuation maps can induce bias in dynamic brain PET studies. Multi-atlas attenuation correction with MaxProb enables quantification on hybrid PET-MR scanners, eschewing the need for CT.

  7. Multi-atlas attenuation correction supports full quantification of static and dynamic brain PET data in PET-MR.

    PubMed

    Mérida, Inés; Reilhac, Anthonin; Redouté, Jérôme; Heckemann, Rolf A; Costes, Nicolas; Hammers, Alexander

    2017-04-07

    In simultaneous PET-MR, attenuation maps are not directly available. Essential for absolute radioactivity quantification, they need to be derived from MR or PET data to correct for gamma photon attenuation by the imaged object. We evaluate a multi-atlas attenuation correction method for brain imaging (MaxProb) on static [ 18 F]FDG PET and, for the first time, on dynamic PET, using the serotoninergic tracer [ 18 F]MPPF. A database of 40 MR/CT image pairs (atlases) was used. The MaxProb method synthesises subject-specific pseudo-CTs by registering each atlas to the target subject space. Atlas CT intensities are then fused via label propagation and majority voting. Here, we compared these pseudo-CTs with the real CTs in a leave-one-out design, contrasting the MaxProb approach with a simplified single-atlas method (SingleAtlas). We evaluated the impact of pseudo-CT accuracy on reconstructed PET images, compared to PET data reconstructed with real CT, at the regional and voxel levels for the following: radioactivity images; time-activity curves; and kinetic parameters (non-displaceable binding potential, BP ND ). On static [ 18 F]FDG, the mean bias for MaxProb ranged between 0 and 1% for 73 out of 84 regions assessed, and exceptionally peaked at 2.5% for only one region. Statistical parametric map analysis of MaxProb-corrected PET data showed significant differences in less than 0.02% of the brain volume, whereas SingleAtlas-corrected data showed significant differences in 20% of the brain volume. On dynamic [ 18 F]MPPF, most regional errors on BP ND ranged from -1 to  +3% (maximum bias 5%) for the MaxProb method. With SingleAtlas, errors were larger and had higher variability in most regions. PET quantification bias increased over the duration of the dynamic scan for SingleAtlas, but not for MaxProb. We show that this effect is due to the interaction of the spatial tracer-distribution heterogeneity variation over time with the degree of accuracy of the attenuation maps. This work demonstrates that inaccuracies in attenuation maps can induce bias in dynamic brain PET studies. Multi-atlas attenuation correction with MaxProb enables quantification on hybrid PET-MR scanners, eschewing the need for CT.

  8. Non-input analysis for incomplete trapping irreversible tracer with PET.

    PubMed

    Ohya, Tomoyuki; Kikuchi, Tatsuya; Fukumura, Toshimitsu; Zhang, Ming-Rong; Irie, Toshiaki

    2013-07-01

    When using metabolic trapping type tracers, the tracers are not always trapped in the target tissue; i.e., some are completely trapped in the target, but others can be eliminated from the target tissue at a measurable rate. The tracers that can be eliminated are termed 'incomplete trapping irreversible tracers'. These incomplete trapping irreversible tracers may be clinically useful when the tracer β-value, the ratio of the tracer (metabolite) elimination rate to the tracer efflux rate, is under approximately 0.1. In this study, we propose a non-input analysis for incomplete trapping irreversible tracers based on the shape analysis (Shape), a non-input analysis used for irreversible tracers. A Monte Carlo simulation study based on experimental monkey data with two actual PET tracers (a complete trapping irreversible tracer [(11)C]MP4A and an incomplete trapping irreversible tracer [(18)F]FEP-4MA) was performed to examine the effects of the environmental error and the tracer elimination rate on the estimation of the k3-parameter (corresponds to metabolic rate) using Shape (original) and modified Shape (M-Shape) analysis. The simulation results were also compared with the experimental results obtained with the two PET tracers. When the tracer β-value was over 0.03, the M-Shape method was superior to the Shape method for the estimation of the k3-parameter. The simulation results were also in reasonable agreement with the experimental ones. M-Shape can be used as the non-input analysis of incomplete trapping irreversible tracers for PET study. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Desorption of radioactive cesium by seawater from the suspended particles in river water.

    PubMed

    Onodera, Masaki; Kirishima, Akira; Nagao, Seiya; Takamiya, Kouichi; Ohtsuki, Tsutomu; Akiyama, Daisuke; Sato, Nobuaki

    2017-10-01

    In 2011, the accident at the Fukushima-Daiichi nuclear power plant dispersed radioactive cesium throughout the environment, contaminating the land, rivers, and sea. Suspended particles containing clay minerals are the transportation medium for radioactive cesium from rivers to the ocean because cesium is strongly adsorbed between the layers of clay minerals, forming inner sphere complexes. In this study, the adsorption and desorption behaviors of radioactive cesium from suspended clay particles in river water have been investigated. The radioactive cesium adsorption and desorption experiments were performed with two kinds of suspended particulate using a batch method with 137 Cs tracers. In the cesium adsorption treatment performed before the desorption experiments, simulated river water having a total cesium concentration ([ 133+137 Cs + ] total ) of 1.3 nM (10 -9  mol/L) was used. The desorption experiments were mainly conducted at a solid-to-liquid ratio of 0.17 g/L. The desorption agents were natural seawater collected at 10 km north of the Fukushima-Daiichi nuclear power plant, artificial seawater, solutions of NaCl, KCl, NH 4 Cl, and 133 CsCl, and ultrapure water. The desorption behavior, which depends on the preloaded cesium concentration in the suspended particles, was also investigated. Based on the cesium desorption experiments using suspended particles, which contained about 1000 ng/g loaded cesium, the order of cesium desorption ratios for each desorption agent was determined as 1 M NaCl (80%) > 470 mM NaCl (65%) > 1 M KCl (30%) ≈ seawater (natural seawater and Daigo artificial seawater) > 1 M NH 4 Cl (20%) > 1 M 133 CsCl (15%) ≫ ultrapure water (2%). Moreover, an interesting result was obtained: The desorption ratio in the 470 mM NaCl solution was much higher than that in seawater, even though the Na + concentrations were identical. These results indicate that the cesium desorption mechanism is not a simple ion exchange reaction but is strongly related to structural changes in the clay minerals in the suspended particles. Hydrated Na + ions expand the interlayer distance of the clay minerals, resulting in the facile desorption of cesium; in contrast, dehydrated K + ions reduce the interlayer distance and inhibit the desorption of cesium. In conclusion, the desorption of cesium from the suspended particles is controlled by the presence of sodium and potassium ions and the preloaded cesium concentration in the suspended particles. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Tracer Kinetic Analysis of (S)-¹⁸F-THK5117 as a PET Tracer for Assessing Tau Pathology.

    PubMed

    Jonasson, My; Wall, Anders; Chiotis, Konstantinos; Saint-Aubert, Laure; Wilking, Helena; Sprycha, Margareta; Borg, Beatrice; Thibblin, Alf; Eriksson, Jonas; Sörensen, Jens; Antoni, Gunnar; Nordberg, Agneta; Lubberink, Mark

    2016-04-01

    Because a correlation between tau pathology and the clinical symptoms of Alzheimer disease (AD) has been hypothesized, there is increasing interest in developing PET tracers that bind specifically to tau protein. The aim of this study was to evaluate tracer kinetic models for quantitative analysis and generation of parametric images for the novel tau ligand (S)-(18)F-THK5117. Nine subjects (5 with AD, 4 with mild cognitive impairment) received a 90-min dynamic (S)-(18)F-THK5117 PET scan. Arterial blood was sampled for measurement of blood radioactivity and metabolite analysis. Volume-of-interest (VOI)-based analysis was performed using plasma-input models; single-tissue and 2-tissue (2TCM) compartment models and plasma-input Logan and reference tissue models; and simplified reference tissue model (SRTM), reference Logan, and SUV ratio (SUVr). Cerebellum gray matter was used as the reference region. Voxel-level analysis was performed using basis function implementations of SRTM, reference Logan, and SUVr. Regionally averaged voxel values were compared with VOI-based values from the optimal reference tissue model, and simulations were made to assess accuracy and precision. In addition to 90 min, initial 40- and 60-min data were analyzed. Plasma-input Logan distribution volume ratio (DVR)-1 values agreed well with 2TCM DVR-1 values (R(2)= 0.99, slope = 0.96). SRTM binding potential (BP(ND)) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 (R(2)= 1.00, slope ≈ 1.00) whereas SUVr(70-90)-1 values correlated less well and overestimated binding. Agreement between parametric methods and SRTM was best for reference Logan (R(2)= 0.99, slope = 1.03). SUVr(70-90)-1 values were almost 3 times higher than BP(ND) values in white matter and 1.5 times higher in gray matter. Simulations showed poorer accuracy and precision for SUVr(70-90)-1 values than for the other reference methods. SRTM BP(ND) and reference Logan DVR-1 values were not affected by a shorter scan duration of 60 min. SRTM BP(ND) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 values. VOI-based data analyses indicated robust results for scan durations of 60 min. Reference Logan generated quantitative (S)-(18)F-THK5117 DVR-1 parametric images with the greatest accuracy and precision and with a much lower white-matter signal than seen with SUVr(70-90)-1 images. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  11. Journal: A Review of Some Tracer-Test Design Equations for Tracer-Mass Estimation and Sample Collection Frequency

    EPA Science Inventory

    Determination of necessary tracer mass, initial sample-collection time, and subsequent sample-collection frequency are the three most difficult aspects to estimate for a proposed tracer test prior to conducting the tracer test. To facilitate tracer-mass estimation, 33 mass-estima...

  12. Measurement of fission product gases in the atmosphere

    NASA Astrophysics Data System (ADS)

    Schell, W. R.; Tobin, M. J.; Marsan, D. J.; Schell, C. W.; Vives-Batlle, J.; Yoon, S. R.

    1997-01-01

    The ability to quickly detect and assess the magnitude of releases of fission-produced radioactive material is of significant importance for ongoing operations of any conventional nuclear power plant or other activities with a potential for fission product release. In most instances, the control limits for the release of airborne radioactivity are low enough to preclude direct air sampling as a means of detection, especially for fission gases that decay by beta or electron emission. It is, therefore, customary to concentrate the major gaseous fission products (krypton, xenon and iodine) by cryogenic adsorption for subsequent separation and measurement. This study summarizes our initial efforts to develop an automated portable system for on-line separation and concentration with the potential for measuring environmental levels of radioactive gases, including 85Kr, 131,133,135Xe, 14C, 3H, 35S, 125,131I, etc., without using cryogenic fluids. Bench top and prototype models were constructed using the principle of heatless fractionation of the gases in a pressure swing system. This method removes the requirement for cryogenic fluids to concentrate gases and, with suitable electron and gamma ray detectors, provides for remote use under automatic computer control. Early results using 133Xe tracer show that kinetic chromatography, i.e., high pressure adsorption of xenon and low pressure desorption of air, using specific types of molecular sieves, permits the separation and quantification of xenon isotopes from large volume air samples. We are now developing the ability to measure the presence and amounts of fission-produced xenon isotopes that decay by internal conversion electrons and beta radiation with short half-lives, namely 131mXe, 11.8 d, 133mXe, 2.2 d, 133Xe, 5.2 d and 135Xe, 9.1 h. The ratio of the isotopic concentrations measured can be used to determine unequivocally the amount of fission gas and time of release of an air parcel many kilometers downwind from a nuclear activity where the fission products were discharged.

  13. A simultaneous beta and coincidence-gamma imaging system for plant leaves

    NASA Astrophysics Data System (ADS)

    Ranjbar, Homayoon; Wen, Jie; Mathews, Aswin J.; Komarov, Sergey; Wang, Qiang; Li, Ke; O'Sullivan, Joseph A.; Tai, Yuan-Chuan

    2016-05-01

    Positron emitting isotopes, such as 11C, 13N, and 18F, can be used to label molecules. The tracers, such as 11CO2, are delivered to plants to study their biological processes, particularly metabolism and photosynthesis, which may contribute to the development of plants that have a higher yield of crops and biomass. Measurements and resulting images from PET scanners are not quantitative in young plant structures or in plant leaves due to poor positron annihilation in thin objects. To address this problem we have designed, assembled, modeled, and tested a nuclear imaging system (simultaneous beta-gamma imager). The imager can simultaneously detect positrons ({β+} ) and coincidence-gamma rays (γ). The imaging system employs two planar detectors; one is a regular gamma detector which has a LYSO crystal array, and the other is a phoswich detector which has an additional BC-404 plastic scintillator for beta detection. A forward model for positrons is proposed along with a joint image reconstruction formulation to utilize the beta and coincidence-gamma measurements for estimating radioactivity distribution in plant leaves. The joint reconstruction algorithm first reconstructs beta and gamma images independently to estimate the thickness component of the beta forward model and afterward jointly estimates the radioactivity distribution in the object. We have validated the physics model and reconstruction framework through a phantom imaging study and imaging a tomato leaf that has absorbed 11CO2. The results demonstrate that the simultaneously acquired beta and coincidence-gamma data, combined with our proposed joint reconstruction algorithm, improved the quantitative accuracy of estimating radioactivity distribution in thin objects such as leaves. We used the structural similarity (SSIM) index for comparing the leaf images from the simultaneous beta-gamma imager with the ground truth image. The jointly reconstructed images yield SSIM indices of 0.69 and 0.63, whereas the separately reconstructed beta alone and gamma alone images had indices of 0.33 and 0.52, respectively.

  14. Simplified data assimilation for simulating wet deposition distribution of radioactive materials in FDNPP accident

    NASA Astrophysics Data System (ADS)

    Saya, A.; Yoshikane, T.; Chang, E. C.; Yoshimura, K.

    2015-12-01

    Due to the massive earthquakes and tsunami on March 11th 2011 in Eastern Japan, Fukushima Daiichi Nuclear Power Plant (FDNPP) was severely damaged. Radioactive materials were released and spread out by atmospheric advection-diffusion. Especially on March 21 - 23th when precipitation was observed, "hotspot" where the high concentration was detected locally. This area was formed in the metropolitan area in Kanto region. Thus, pollution at water treatment plants because of the deposition became a concern. Therefore, the reliable information of the hotspot is expected. Currently, atmospheric transport simulations by numerical models are developed for reproduction of the distribution. However, there are some uncertainties in the simulations. In the case of hotspot, accuracy of simulated precipitation have to be well considered because the hotspot seemed to be formed by wet deposition. We modified the stable isotope mode of Regional Spectral Model (IsoRSM) to enable to simulate the transport of the radioactive tracers, namely 131I and 137Cs, by including the dry and wet deposition processes. As the simplified data assimilation, simulated precipitation was replaced with Radar-AMeDAS precipitation data (RAP). RAP was assimilated in the post-process, after running simulations, to redistribute wet deposition of 137Cs. The ratio of 137Cs deposited from the cumulative vertical column with precipitation in the domain was not changed, however its pattern was redistributed corresponding with RAP and simulated concentration. As a result, the redistributed wet deposition was within factor 10 to 2 compared with the fallout data in Kanto region, and further data assimilation would be contributed. In addition, we found that due to the arrival time of the plume in the morning on 21st and the border time of daily observation data of fallout, validation result might be worse even though hourly distributions are well simulated.

  15. A simultaneous beta and coincidence-gamma imaging system for plant leaves.

    PubMed

    Ranjbar, Homayoon; Wen, Jie; Mathews, Aswin J; Komarov, Sergey; Wang, Qiang; Li, Ke; O'Sullivan, Joseph A; Tai, Yuan-Chuan

    2016-05-07

    Positron emitting isotopes, such as (11)C, (13)N, and (18)F, can be used to label molecules. The tracers, such as (11)CO2, are delivered to plants to study their biological processes, particularly metabolism and photosynthesis, which may contribute to the development of plants that have a higher yield of crops and biomass. Measurements and resulting images from PET scanners are not quantitative in young plant structures or in plant leaves due to poor positron annihilation in thin objects. To address this problem we have designed, assembled, modeled, and tested a nuclear imaging system (simultaneous beta-gamma imager). The imager can simultaneously detect positrons ([Formula: see text]) and coincidence-gamma rays (γ). The imaging system employs two planar detectors; one is a regular gamma detector which has a LYSO crystal array, and the other is a phoswich detector which has an additional BC-404 plastic scintillator for beta detection. A forward model for positrons is proposed along with a joint image reconstruction formulation to utilize the beta and coincidence-gamma measurements for estimating radioactivity distribution in plant leaves. The joint reconstruction algorithm first reconstructs beta and gamma images independently to estimate the thickness component of the beta forward model and afterward jointly estimates the radioactivity distribution in the object. We have validated the physics model and reconstruction framework through a phantom imaging study and imaging a tomato leaf that has absorbed (11)CO2. The results demonstrate that the simultaneously acquired beta and coincidence-gamma data, combined with our proposed joint reconstruction algorithm, improved the quantitative accuracy of estimating radioactivity distribution in thin objects such as leaves. We used the structural similarity (SSIM) index for comparing the leaf images from the simultaneous beta-gamma imager with the ground truth image. The jointly reconstructed images yield SSIM indices of 0.69 and 0.63, whereas the separately reconstructed beta alone and gamma alone images had indices of 0.33 and 0.52, respectively.

  16. Effect of dietary docosahexaenoic acid (DHA) in phospholipids or triglycerides on brain DHA uptake and accretion.

    PubMed

    Kitson, Alex P; Metherel, Adam H; Chen, Chuck T; Domenichiello, Anthony F; Trépanier, Marc-Olivier; Berger, Alvin; Bazinet, Richard P

    2016-07-01

    Tracer studies suggest that phospholipid DHA (PL-DHA) more effectively targets the brain than triglyceride DHA (TAG-DHA), although the mechanism and whether this translates into higher brain DHA concentrations are not clear. Rats were gavaged with [U-(3)H]PL-DHA and [U-(3)H]TAG-DHA and blood sampled over 6h prior to collection of brain regions and other tissues. In another experiment, rats were supplemented for 4weeks with TAG-DHA (fish oil), PL-DHA (roe PL) or a mixture of both for comparison to a low-omega-3 diet. Brain regions and other tissues were collected, and blood was sampled weekly. DHA accretion rates were estimated using the balance method. [U-(3)H]PL-DHA rats had higher radioactivity in cerebellum, hippocampus and remainder of brain, with no differences in other tissues despite higher serum lipid radioactivity in [U-(3)H]TAG-DHA rats. TAG-DHA, PL-DHA or a mixture were equally effective at increasing brain DHA. There were no differences between DHA-supplemented groups in brain region, whole-body, or tissue DHA accretion rates except heart and serum TAG where the PL-DHA/TAG-DHA blend was higher than TAG-DHA. Apparent DHA β-oxidation was not different between DHA-supplemented groups. This indicates that more labeled DHA enters the brain when consumed as PL; however, this may not translate into higher brain DHA concentrations. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Comparison of balance of tritium activity in waste water from nuclear power plants and at selected monitoring sites in the Vltava River, Elbe River and Jihlava (Dyje) River catchments in the Czech Republic.

    PubMed

    Hanslík, Eduard; Marešová, Diana; Juranová, Eva; Sedlářová, Barbora

    2017-12-01

    During the routine operation, nuclear power plants discharge waste water containing a certain amount of radioactivity, whose main component is the artificial radionuclide tritium. The amounts of tritium released into the environment are kept within the legal requirements, which minimize the noxious effects of radioactivity, but the activity concentration is well measurable in surface water of the recipient. This study compares amount of tritium activity in waste water from nuclear power plants and the tritium activity detected at selected relevant sites of surface water quality monitoring. The situation is assessed in the catchment of the Vltava and Elbe Rivers, affected by the Temelín Nuclear Power Plant as well as in the Jihlava River catchment (the Danube River catchment respectively), where the waste water of the Dukovany Nuclear Power Plant is discharged. The results show a good agreement of the amount of released tritium stated by the power plant operator and the tritium amount detected in the surface water and highlighted the importance of a robust independent monitoring of tritium discharged from a nuclear power plant which could be carried out by water management authorities. The outputs of independent monitoring allow validating the values reported by a polluter and expand opportunities of using tritium as e.g. tracer. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Exploring the radiosynthesis and in vitro characteristics of [68 Ga]Ga-DOTA-Siglec-9.

    PubMed

    Jensen, Svend B; Käkelä, Meeri; Jødal, Lars; Moisio, Olli; Alstrup, Aage K O; Jalkanen, Sirpa; Roivainen, Anne

    2017-07-01

    Vascular adhesion protein 1 is a leukocyte homing-associated glycoprotein, which upon inflammation rapidly translocates from intracellular sources to the endothelial cell surface. It has been discovered that the cyclic peptide residues 283-297 of sialic acid-binding IgG-like lectin 9 (Siglec-9) "CARLSLSWRGLTLCPSK" bind to vascular adhesion protein 1 and hence makes the radioactive analogues of this compound ([ 68 Ga]Ga-DOTA-Siglec-9) interesting as a noninvasive visualizing marker of inflammation. Three different approaches to the radiosynthesis of [ 68 Ga]Ga-DOTA-Siglec-9 are presented and compared with previously published methods. A simple, robust radiosynthesis of [ 68 Ga]Ga-DOTA-Siglec-9 with a yield of 62% (non decay-corrected) was identified, and it had a radiochemical purity >98% and a specific radioactivity of 35 MBq/nmol. Furthermore, the protein binding and stability of [ 68 Ga]Ga-DOTA-Siglec-9 were analyzed in vitro in mouse, rat, rabbit, pig, and human plasma and compared with in vivo pig results. The plasma in vitro protein binding of [ 68 Ga]Ga-DOTA-Siglec-9 was the lowest in the pig followed by rabbit, human, rat, and mouse. It was considerably higher in the in vivo pig experiments. The in vivo stability in pigs was lower than the in vitro stability. Despite considerable species differences, the observed characteristics of [ 68 Ga]Ga-DOTA-Siglec-9 are suitable as a positron emission tomography tracer. Copyright © 2017 John Wiley & Sons, Ltd.

  19. A consolidated environmental monitoring plan for Aberdeen Proving Ground, Maryland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ebinger, M.H.; Hansen, W.R.

    1997-04-01

    The US Army operates facilities in Edgewood and Aberdeen under several licenses from the Nuclear Regulatory Commission (NRC). Compliance with each license is time consuming and could potentially result in duplicated efforts to demonstrate compliance with existing environmental regulations. The goal of the ERM plan is to provide the sampling necessary to ensure that operations at Edgewood and Aberdeen are within applicable regulatory guidelines and to provide a means of ensuring that adverse effects to the environment are minimized. Existing sampling plans and environmental data generated from those plans are briefly reviewed as part of the development of the presentmore » ERM plan. The new ERM plan was designed to provide data that can be used for assessing risks to the environment and to humans using Aberdeen and Edgewood areas. Existing sampling is modified and new sampling is proposed based on the results of the long-term DU fate study. In that study, different environmental pathways were identified that would show transport of DU at Aberdeen. Those pathways would also be impacted by other radioactive constituents from Aberdeen and Edgewood areas. The ERM plan presented in this document includes sampling from Edgewood and Aberdeen facilities. The main radioactive constituents of concern at Edgewood are C, P, N, S, H, I, Co, Cs, Ca, Sr and U that are used in radiolabeling different compounds and tracers for different reactions and syntheses. Air and water sampling are the thrust of efforts at the Edgewood area.« less

  20. Topic III - Infiltration and Drainage: A section in Joint US Geological Survey, US Nuclear Regulatory Commission workshop on research related to low-level radioactive waste disposal, May 4-6, 1993, National Center, Reston, Virginia; Proceedings (WRI 95-4015)

    USGS Publications Warehouse

    Prudic, David E.; Gee, Glendon; Stevens, Peter R.; Nicholson, Thomas J.

    1996-01-01

    Infiltration into and drainage from facilities for the disposal of low-level radioactive wastes is considered the major process by which non-volatile contaminants are transported away from the facilities. The session included 10 papers related to the processes of infiltration and drainage, and to the simulation of flow and transport through the unsaturated zone. The first paper, presented by David Stonestrom, was an overview regarding the application of unsaturated flow theory to infiltration and drainage. Stonestrom posed three basic questions, which are:How well do we know the relevant processes affecting flow and transport?How well can we measure the parametric functions used to quantify flow and transport?How do we treat complexities inherent in field settings?The other nine papers presented during the session gave some insight to these questions. Topics included: laboratory measurement of unsaturated hydraulic conductivities at low water contents, by John Nimmo; use of environmental tracers to identify preferential flow through fractured media and to quantify drainage, by Edmund Prych and Edwin Weeks; field experiments to evaluate relevant processes affecting infiltration and drainage, by Brian Andraski, Glendon Gee, and Peter Wierenga; and the use of determinist'c and stochastic models for simulating flow and transport through heterogeneous sediments, by Richard Hills, Lynn Gelhar, and Shlomo Neuman.

  1. Hydrological tracers using nanobiotechnology: proof of concept.

    PubMed

    Sharma, Asha N; Luo, Dan; Walter, M Todd

    2012-08-21

    In order to answer questions that involve differentiating among multiple and potentially interacting hydrological flowpaths, it would be ideal to use multiple tracers with identical transport properties that can nonetheless be distinguished from each other. This paper describes the development and proof of concept of a new kind of engineered tracer system that allows a large number of individual tracers to be simultaneously distinguished from one another. This new tracer is composed of polylactic acid (PLA) microspheres into which short strands of synthetic DNA and paramagnetic iron oxide nanoparticles are incorporated. The synthetic DNA serves as the "label" or "tag" in our tracers that allow us to distinguish one tracer from another, and paramagnetic iron oxide nanoparticles are included in the tracer to facilitate magnetic concentration of the tracers in potentially dilute water samples. Some potential advantages of this tracer concept include: virtually limitless uniquely labeled tracers, highly sensitive detection, and relatively moderate expense. Three proof-of-concept experiments at scales ranging from orders of 10 cm to 100 m demonstrated the use of the tracer system.

  2. Biodisposition and metabolism of [18F]fluorocholine in 9L glioma cells and 9L glioma-bearing Fisher rats

    PubMed Central

    Bansal, Aditya; Shuyan, Wang; Hara, Toshiko; Harris, Robert A.; DeGrado, Timothy R.

    2008-01-01

    Purpose [18F]Fluorocholine [18F]FCH) was developed as an analog of [11C]choline for tumor imaging, however, its metabolic handling remains ill-defined. In this study, the metabolism of [18F]FCH is evaluated in cultured 9L glioma cells and Fisher 344 rats bearing 9L glioma tumors. Methods 9L glioma cells were incubated with [18F]FCH and [14C]choline under normoxic and hypoxic (1% O2) conditions and analyzed for metabolic fate. [18F]FCH and [14C]choline kinetics and metabolism were studied in Fisher 344 rats bearing subcutaneous 9L tumors. Results [18F]FCH and [14C]choline were similarly metabolized in 9L cells in both normoxic and hypoxic conditions over a 2 hr incubation period. In normoxia, radioactivity was predominantly in phosphorylated form for both tracers after 5 min incubation. In hypoxia, the tracers remained mainly in nonmetabolized form at early timepoints (< 20 min). Slow dephosphorylation of intracellular [18F]phosphofluorocholine (0.043–0.060 min−1) and [14C]phosphocholine (0.072–0.088 min−1) was evidenced via efflux measurements. In rat, both [18F]FCH and [14C]choline showed high renal and hepatic uptake. Blood clearance of both tracers was rapid with oxidative metabolites, [18F]fluorobetaine and [14C]betaine, representing the majority of radiolabel in plasma after 5 min post-injection. Oxidation (in liver) and lipid incorporation (in lung) were somewhat slower for [18F]FCH relative to [14C]choline. The majority of radiolabel in hypoxic subcutaneous tumor, as in hypoxic cultured 9L cells, was found as nonmetabolized [18F]FCH and [14C]choline. Conclusions [18F]FCH mimics choline uptake and metabolism by 9L glioma cells and tumors. However, subtle changes in biodistribution, oxidative metabolism, dephosphorylation, lipid incorporation and renal excretion show moderate effects of the presence of the radiofluorine atom in [18F]FCH. The decrease in phosphorylation of exogenous choline by cancer cells should be considered in interpretation of PET images in characteristically hypoxic tumors. PMID:18264706

  3. Simultaneous measurement of glucose transport and utilization in the human brain

    PubMed Central

    Shestov, Alexander A.; Emir, Uzay E.; Kumar, Anjali; Henry, Pierre-Gilles; Seaquist, Elizabeth R.

    2011-01-01

    Glucose is the primary fuel for brain function, and determining the kinetics of cerebral glucose transport and utilization is critical for quantifying cerebral energy metabolism. The kinetic parameters of cerebral glucose transport, KMt and Vmaxt, in humans have so far been obtained by measuring steady-state brain glucose levels by proton (1H) NMR as a function of plasma glucose levels and fitting steady-state models to these data. Extraction of the kinetic parameters for cerebral glucose transport necessitated assuming a constant cerebral metabolic rate of glucose (CMRglc) obtained from other tracer studies, such as 13C NMR. Here we present new methodology to simultaneously obtain kinetic parameters for glucose transport and utilization in the human brain by fitting both dynamic and steady-state 1H NMR data with a reversible, non-steady-state Michaelis-Menten model. Dynamic data were obtained by measuring brain and plasma glucose time courses during glucose infusions to raise and maintain plasma concentration at ∼17 mmol/l for ∼2 h in five healthy volunteers. Steady-state brain vs. plasma glucose concentrations were taken from literature and the steady-state portions of data from the five volunteers. In addition to providing simultaneous measurements of glucose transport and utilization and obviating assumptions for constant CMRglc, this methodology does not necessitate infusions of expensive or radioactive tracers. Using this new methodology, we found that the maximum transport capacity for glucose through the blood-brain barrier was nearly twofold higher than maximum cerebral glucose utilization. The glucose transport and utilization parameters were consistent with previously published values for human brain. PMID:21791622

  4. Assessment of 11C-labeled-4-N-(3-bromoanilino)-6,7-dimethoxyquinazoline as a positron emission tomography agent to monitor epidermal growth factor receptor expression.

    PubMed

    Wang, Hui; Yu, Jinming; Yang, Guoren; Song, Xianrang; Sun, Xiaorong; Zhao, Shuqiang; Mu, Dianbin

    2007-09-01

    The aim of the present study was to investigate the biodistribution of (11)C-labeled-4-N-(3-bromoanilino), 6,7-dimethoxyquinazoline ((11)C-PD153035) and the relationship between accumulation of the tracer and epidermal growth factor receptor (EGFR) expression levels. Biodistribution studies of (11)C-PD153035 were performed in tumor-bearing nude mice. The amount of radioactivity in the lungs was small while concentrations were highest in the liver and intestine. From in vitro studies, the level of (11)C-PD153035 accumulation was detected in MDA-MB-468, A549, and MDA-MB-231 cells. The uptake of (11)C-PD153035 in cells was closely correlated with the EGFR expression level of cells (r(2) = 0.85; P < 0.001), and the results obtained in excised tumors were also significantly correlated (r(2) = 0.63; P = 0.003). Binding in MDA-MB-468, A549, and MDA-MB-231 tumors was reduced to background level at 60 min post injection( 11)C-PD153035 by pretreatment with cold PD153035. The present study showed that whether in vitro or ex vivo the uptake of (11)C-PD153035 closely correlated with EGFR expression levels. In contrast, blocking studies revealed specific binding in the three kinds of tumors. Thus (11)C-PD153035 may be used as a positron emission tomography tracer to yield useful information about tumors, particularly for lung cancer with different EGFR expression levels.

  5. Development and application of mass spectrometric techniques for ultra-trace determination of 236U in environmental samples-A review.

    PubMed

    Bu, Wenting; Zheng, Jian; Ketterer, Michael E; Hu, Sheng; Uchida, Shigeo; Wang, Xiaolin

    2017-12-01

    Measurements of the long-lived radionuclide 236 U are an important endeavor, not only in nuclear safeguards work, but also in terms of using this emerging nuclide as a tracer in chemical oceanography, hydrology, and actinide sourcing. Depending on the properties of a sample and its neutron irradiation history, 236 U/ 238 U ratios from different sources vary significantly. Therefore, this ratio can be treated as an important fingerprint for radioactive source identification, and in particular, affords a definitive means of discriminating between naturally occurring U and specific types of anthropogenic U. The development of mass spectrometric techniques makes it possible to determine ultra-trace levels of 236 U in environmental samples. In this paper, we review the current status of mass spectrometric approaches for determination of 236 U in environmental samples. Various sample preparation methods are summarized and compared. The mass spectrometric techniques emphasized herein are thermal ionization mass spectrometry (TIMS), inductively coupled plasma mass spectrometry (ICP-MS) and accelerator mass spectrometry (AMS). The strategies or principles used by each technique for the analysis of 236 U are described. The performances of these techniques in terms of abundance sensitivity and detection limit are discussed in detail. To date, AMS exhibits the best capability for ultra-trace determinations of 236 U. The levels and behaviors of 236 U in various environmental media are summarized and discussed as well. Results suggest that 236 U has an important, emerging role as a tracer for geochemical studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. A compact bio-inspired visible/NIR imager for image-guided surgery (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Gao, Shengkui; Garcia, Missael; Edmiston, Chris; York, Timothy; Marinov, Radoslav; Mondal, Suman B.; Zhu, Nan; Sudlow, Gail P.; Akers, Walter J.; Margenthaler, Julie A.; Liang, Rongguang; Pepino, Marta; Achilefu, Samuel; Gruev, Viktor

    2016-03-01

    Inspired by the visual system of the morpho butterfly, we have designed, fabricated, tested and clinically translated an ultra-sensitive, light weight and compact imaging sensor capable of simultaneously capturing near infrared (NIR) and visible spectrum information. The visual system of the morpho butterfly combines photosensitive cells with spectral filters at the receptor level. The spectral filters are realized by alternating layers of high and low dielectric constant, such as air and cytoplasm. We have successfully mimicked this concept by integrating pixelated spectral filters, realized by alternating silicon dioxide and silicon nitrate layers, with an array of CCD detectors. There are four different types of pixelated spectral filters in the imaging plane: red, green, blue and NIR. The high optical density (OD) of all spectral filters (OD>4) allow for efficient rejections of photons from unwanted bands. The single imaging chip weighs 20 grams with form factor of 5mm by 5mm. The imaging camera is integrated with a goggle display system. A tumor targeted agent, LS301, is used to identify all spontaneous tumors in a transgenic PyMT murine model of breast cancer. The imaging system achieved sensitivity of 98% and selectivity of 95%. We also used our imaging sensor to locate sentinel lymph nodes (SLNs) in patients with breast cancer using indocyanine green tracer. The surgeon was able to identify 100% of SLNs when using our bio-inspired imaging system, compared to 93% when using information from the lymphotropic dye and 96% when using information from the radioactive tracer.

  7. Synthesis, radiosynthesis and in vitro evaluation of 18F-Bodipy-C16/triglyceride as a dual modal imaging agent for brown adipose tissue

    PubMed Central

    Maenen, Marco; Drude, Natascha; Nascimento, Emmani B. M.; van Marken Lichtenbelt, Wouter D.; Mottaghy, Felix M.; Bauwens, Matthias

    2017-01-01

    Background Brown adipose tissue research is in the focus in the field of endocrinology. We designed a dual-modal fluorescent/PET fatty acid based tracer on commercially available Bodipy-C16, which can be synthesized to its corresponding triglyceride and which combines the benefits of fluorescent and PET imaging. Methods Bodipy-C16 was coupled to 1,3-diolein resulting in Bodipy-triglyceride. Bodipy-C16 and Bodipy-triglyceride compounds were radiolabeled with 18F using an 18F/19F exchange reaction to yield a dual-modal imaging molecule. Uptake of radiolabeled and non-labeled Bodipy-C16 and Bodipy-triglyceride was analyzed by fluorescence imaging and radioactive uptake in cultured adipocytes derived from human brown adipose tissue and white adipose tissue. Results Bodipy-C16 and Bodipy-triglyceride were successfully radiolabeled and Bodipy-C16 showed high shelf life and blood plasma stability (99% from 0–4 h). The uptake of Bodipy-C16 increased over time in cultured adipocytes, which was further enhanced after beta-adrenergic stimulation with norepinephrine. The uptake of Bodipy-C16 was inhibited by oleic acid and CD36 inhibitor sulfosuccinimidyl-oleate. The poor solubility of Bodipy-triglyceride did not allow stability or in vitro experiments. Conclusion The new developed dual modal fatty acid based tracers Bodipy-C16 and Bodipy-triglyceride showed promising results to stimulate further in vivo evaluation and will help to understand brown adipose tissues role in whole body energy expenditure. PMID:28817670

  8. Innovative techniques for the description of reservoir heterogeneity using tracers. Second technical annual progress report, October 1991--September 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, G.A.; Sepehrnoori, K.

    1992-12-31

    This second annual report on innovative uses of tracers for reservoir characterization contains four sections each describing a novel use of oilfield tracers. The first section describes and illustrates the use of a new single-well tracer test to estimate wettability. This test consists of the injection of brine containing tracers followed by oil containing tracers, a shut-in period to allow some of the tracers to react, and then production of the tracers. The inclusion of the oil injection slug with tracers is unique to this test, and this is what makes the test work. We adapted our chemical simulator, UTCHEM,more » to enable us to study this tracer method and made an extensive simulation study to evaluate the effects of wettability based upon characteristic curves for relative permeability and capillary pressure for differing wetting states typical of oil reservoirs. The second section of this report describes a new method for analyzing interwell tracer data based upon a type-curve approach. Theoretical frequency response functions were used to build type curves of ``transfer function`` and ``phase spectrum`` that have dimensionless heterogeneity index as a parameter to characterize a stochastic permeability field. We illustrate this method by analyzing field tracer data. The third section of this report describes a new theory for interpreting interwell tracer data in terms of channeling and dispersive behavior for reservoirs. Once again, a stochastic approach to reservoir description is taken. The fourth section of this report describes our simulation of perfluorocarbon gas tracers. This new tracer technology developed at Brookhaven National Laboratory is being tested at the Elk Hills Naval Petroleum Reserve No. 1 in California. We report preliminary simulations made of these tracers in one of the oil reservoirs under evaluation with these tracers in this field. Our compostional simulator (UTCOMP) was used for this simulation study.« less

  9. Accounting for pharmacokinetic differences in dual-tracer receptor density imaging

    PubMed Central

    Tichauer, K M; Diop, M; Elliott, J T; Samkoe, K S; Hasan, T; St. Lawrence, K; Pogue, B W

    2014-01-01

    Dual-tracer molecular imaging is a powerful approach to quantify receptor expression in a wide range of tissues by using an untargeted tracer to account for any nonspecific uptake of a molecular-targeted tracer. This approach has previously required the pharmacokinetics of the receptor-targeted and untargeted tracers to be identical, requiring careful selection of an ideal untargeted tracer for any given targeted tracer. In this study, methodology capable of correcting for tracer differences in arterial input functions, as well as binding-independent delivery and retention, is derived and evaluated in a mouse U251 glioma xenograft model using an Affibody tracer targeted to epidermal growth factor receptor (EGFR), a cell membrane receptor overexpressed in many cancers. Simulations demonstrated that blood, and to a lesser extent vascular-permeability, pharmacokinetic differences between targeted and untargeted tracers could be quantified by deconvolving the uptakes of the two tracers in a region of interest devoid of targeted tracer binding, and therefore corrected for, by convolving the uptake of the untargeted tracer in all regions of interest by the product of the deconvolution. Using fluorescently labelled, EGFR-targeted and untargeted Affibodies (known to have different blood clearance rates), the average tumor concentration of EGFR in 4 mice was estimated using dual-tracer kinetic modelling to be 3.9 ± 2.4 nM compared to an expected concentration of 2.0 ± 0.4 nM. However, with deconvolution correction a more equivalent EGFR concentration of 2.0 ± 0.4 nM was measured. PMID:24743262

  10. Impact of solvent granularity and layering on tracer hydrodynamics in confinement.

    PubMed

    Bollinger, Jonathan A; Carmer, James; Jain, Avni; Truskett, Thomas M

    2016-11-28

    Classic hydrodynamic arguments establish that when a spherical tracer particle is suspended between parallel walls, tracer-wall coupling mediated by the solvent will cause the tracer to exhibit position-dependent diffusivity. We investigate how the diffusivity profiles of confined tracers are impacted by the diameter size-ratio of the tracer to solvent: starting from the classic limit of infinite size-ratio (i.e., continuum solvent), we consider size-ratios of four or less to examine how hydrodynamic predictions are disrupted for systems where the tracer and solvent are of similar scale. We use computer simulations and techniques based on the Fokker-Planck formalism to calculate the diffusivity profiles of hard-sphere tracer particles in hard-sphere solvents, focusing on the dynamics perpendicular to the walls. Given wall separations of several tracer diameters, we first consider confinement between hard walls, where anisotropic structuring at the solvent lengthscale generates inhomogeneity in the tracer free-energy landscape and undermines hydrodynamic predictions locally. We then introduce confining planes that we term transparent walls, which restrict tracer and solvent center-accessibilities while completely eliminating static anisotropy, and reveal position-dependent signatures in tracer diffusivity solely attributable to confinement. With or without suppressing static heterogeneity, we find that tracer diffusivity increasingly deviates on a local basis from hydrodynamic predictions at smaller size-ratios. However, hydrodynamic theory still approximately captures spatially-averaged dynamics across the pores even for very small tracer-solvent size-ratios over a wide range of solvent densities and wall separations.

  11. A novel double-tracer technique to characterize absorption, distribution, metabolism and excretion (ADME) of [14C]tofogliflozin after oral administration and concomitant intravenous microdose administration of [13C]tofogliflozin in humans.

    PubMed

    Schwab, Dietmar; Portron, Agnes; Backholer, Zoe; Lausecker, Berthold; Kawashima, Kosuke

    2013-06-01

    Human mass balance studies and the assessment of absolute oral bioavailability (F) are usually assessed in separate studies. Intravenous microdose administration of an isotope tracer concomitant to an unlabeled oral dose is an emerging technique to assess F. We report a novel double-tracer approach implemented for tofogliflozin combining oral administration of a radiolabel tracer with concomitant intravenous administration of a stable isotope tracer. Tofogliflozin is a potent and selective sodium/glucose cotransporter 2 inhibitor for the treatment of type 2 diabetes mellitus currently in clinical development. The objectives of the present study were to assess the systemic exposure of major circulating metabolites, excretion balance, F and contribution of renal clearance (CLR) to total clearance (CL) of tofogliflozin in healthy subjects within one study applying a novel double-tracer technique. Six healthy male subjects received 20 mg [(12)C/(14)C]tofogliflozin (3.73 MBq) orally and a concomitant microdose of 0.1 mg [(13)C]tofogliflozin intravenously. Pharmacokinetics of tofogliflozin were determined for the oral and intravenous route; the pharmacokinetics of the metabolites M1 and M5 were determined for the oral route. Quantification of [(12)C]tofogliflozin in plasma and urine and [(13)C]tofogliflozin in plasma was performed by selective LC-MS/MS methods. For the pre-selected metabolites of tofogliflozin, M1 and M5, a validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) was applied to plasma and urine samples. Total radioactivity was assessed in plasma, urine and feces. Pharmacokinetic analysis was conducted by non-compartmental methods. The pharmacokinetics of tofogliflozin in healthy subjects were characterized by an F of 97.5 ± 12.3 %, CL of 10.0 ± 1.3 l/h and volume of distribution at steady-state (V(ss)) of 50.6 ± 6.7 l. The main route of elimination of total drug-related material was by excretion into urine (77.0 ± 4.1 % of the dose). The observed CL(R) of 25.7 ± 5.0 ml/min was higher than the product of the estimated glomerular filtration rate (eGFR) and fraction unbound in plasma (f(u)) (eGFR × f(u) 15 ml/min), indicating the presence of net active tubular secretion in the renal elimination of tofogliflozin. However, CLR contributed only 15.5 % to the CL of tofogliflozin, suggesting that reductions in CLR by renal impairment won't significantly affect systemic exposure to tofogliflozin. Tofogliflozin and its metabolite M1 were the only major circulating entities accounting for 46 ± 8.6 and 50 ± 8.2 %, respectively, of total circulating drug-related material, while the metabolite M5 was a minor circulating metabolite accounting for 3.0 ± 0.3 % of total circulating drug-related material. Both the M1 and M5 metabolites were excreted into urine and the major metabolite M1 did not exhibit active tubular secretion. These results demonstrate the utility of the double-tracer approach to provide essential pharmacokinetic data and excretion data for drug-related material in one study at the same dosing occasion. The data obtained allowed the characterization of absorption, distribution, metabolism and excretion of tofogliflozin. Tofogliflozin exhibited highly favorable pharmacokinetic properties as demonstrated by its high F, low CL and a low V(ss. The presence of only one major circulating metabolite of tofogliflozin was unambiguously demonstrated. As a drug targeting the kidney, luminal exposure of the kidney is achieved by renal filtration and active tubular secretion.

  12. Pharmacokinetic Modeling of Manganese III. Physiological Approaches Accounting for Background and Tracer Kinetics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teeguarden, Justin G.; Gearhart, Jeffrey; Clewell, III, H. J.

    2007-01-01

    Manganese (Mn) is an essential nutrient. Mn deficiency is associated with altered lipid (Kawano et al. 1987) and carbohydrate metabolism (Baly et al. 1984; Baly et al. 1985), abnormal skeletal cartilage development (Keen et al. 2000), decreased reproductive capacity, and brain dysfunction. Occupational and accidental inhalation exposures to aerosols containing high concentrations of Mn produce neurological symptoms with Parkinson-like characteristics in workers. At present, there is also concern about use of the manganese-containing compound, methylcyclopentadienyl manganese tricarbonyl (MMT), in unleaded gasoline as an octane enhancer. Combustion of MMT produces aerosols containing a mixture of manganese salts (Lynam et al. 1999).more » These Mn particulates may be inhaled at low concentrations by the general public in areas using MMT. Risk assessments for essential elements need to acknowledge that risks occur with either excesses or deficiencies and the presence of significant amounts of these nutrients in the body even in the absence of any exogenous exposures. With Mn there is an added complication, i.e., the primary risk is associated with inhalation while Mn is an essential dietary nutrient. Exposure standards for inhaled Mn will need to consider the substantial background uptake from normal ingestion. Andersen et al. (1999) suggested a generic approach for essential nutrient risk assessment. An acceptable exposure limit could be based on some ‘tolerable’ change in tissue concentration in normal and exposed individuals, i.e., a change somewhere from 10 to 25 % of the individual variation in tissue concentration seen in a large human population. A reliable multi-route, multi-species pharmacokinetic model would be necessary for the implementation of this type of dosimetry-based risk assessment approach for Mn. Physiologically-based pharmacokinetic (PBPK) models for various xenobiotics have proven valuable in contributing to a variety of chemical specific risk assessments (Dixit et al., 2003). With most exogenous compounds, there is often no background exposure and body concentrations are not under active control from homeostatic processes as occurs with essential nutrients. Any complete Mn PBPK model would include the homeostatic regulation as an essential nutritional element and the additional exposure routes by inhalation. Two companion papers discuss the kinetic complexities of the quantitative dose-dependent alterations in hepatic and intestinal processes that control uptake and elimination of Mn (Teeguarden et al., 2006a, b). Radioactive 54Mn has been to investigate the behavior of the more common 55Mn isotope in the body because the distribution and elimination of tracer doses reflects the overall distributional characteristics of Mn. In this paper, we take the first steps in developing a multi-route PBPK model for Mn. Here we develop a PBPK model to account for tissue concentrations and tracer kinetics of Mn under normal dietary intake. This model for normal levels of Mn will serve as the starting point for more complete model descriptions that include dose-dependencies in both oral uptake and and biliary excretion. Material and Methods Experimental Data Two studies using 54Mn tracer were employed in model development. (Furchner et al. 1966; Wieczorek and Oberdorster 1989). In Furchner et al. (1966) male Sprague-Dawley rats received an ip injection of carrier-free 54MnCl2 while maintained on standard rodent feed containing ~ 45 ppm Mn. Tissue radioactivity of 54Mn was measured by liquid scintillation counting between post injection days 1 to 89 and reported as percent of administered dose per kg tissue. 54Mn time courses were reported for liver, kidney, bone, brain, muscle, blood, lung and whole body. Because ip uptake is via the portal circulation to the liver, this data set had information on distribution and clearance behaviors of Mn entering the systemic circulation from liver.« less

  13. Methodology for quantitative rapid multi-tracer PET tumor characterizations.

    PubMed

    Kadrmas, Dan J; Hoffman, John M

    2013-10-04

    Positron emission tomography (PET) can image a wide variety of functional and physiological parameters in vivo using different radiotracers. As more is learned about the molecular basis for disease and treatment, the potential value of molecular imaging for characterizing and monitoring disease status has increased. Characterizing multiple aspects of tumor physiology by imaging multiple PET tracers in a single patient provides additional complementary information, and there is a significant body of literature supporting the potential value of multi-tracer PET imaging in oncology. However, imaging multiple PET tracers in a single patient presents a number of challenges. A number of techniques are under development for rapidly imaging multiple PET tracers in a single scan, where signal-recovery processing algorithms are employed to recover various imaging endpoints for each tracer. Dynamic imaging is generally used with tracer injections staggered in time, and kinetic constraints are utilized to estimate each tracers' contribution to the multi-tracer imaging signal. This article summarizes past and ongoing work in multi-tracer PET tumor imaging, and then organizes and describes the main algorithmic approaches for achieving multi-tracer PET signal-recovery. While significant advances have been made, the complexity of the approach necessitates protocol design, optimization, and testing for each particular tracer combination and application. Rapid multi-tracer PET techniques have great potential for both research and clinical cancer imaging applications, and continued research in this area is warranted.

  14. Methodology for Quantitative Rapid Multi-Tracer PET Tumor Characterizations

    PubMed Central

    Kadrmas, Dan J.; Hoffman, John M.

    2013-01-01

    Positron emission tomography (PET) can image a wide variety of functional and physiological parameters in vivo using different radiotracers. As more is learned about the molecular basis for disease and treatment, the potential value of molecular imaging for characterizing and monitoring disease status has increased. Characterizing multiple aspects of tumor physiology by imaging multiple PET tracers in a single patient provides additional complementary information, and there is a significant body of literature supporting the potential value of multi-tracer PET imaging in oncology. However, imaging multiple PET tracers in a single patient presents a number of challenges. A number of techniques are under development for rapidly imaging multiple PET tracers in a single scan, where signal-recovery processing algorithms are employed to recover various imaging endpoints for each tracer. Dynamic imaging is generally used with tracer injections staggered in time, and kinetic constraints are utilized to estimate each tracers' contribution to the multi-tracer imaging signal. This article summarizes past and ongoing work in multi-tracer PET tumor imaging, and then organizes and describes the main algorithmic approaches for achieving multi-tracer PET signal-recovery. While significant advances have been made, the complexity of the approach necessitates protocol design, optimization, and testing for each particular tracer combination and application. Rapid multi-tracer PET techniques have great potential for both research and clinical cancer imaging applications, and continued research in this area is warranted. PMID:24312149

  15. Journal: Efficient Hydrologic Tracer-Test Design for Tracer ...

    EPA Pesticide Factsheets

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed to facilitate the design of tracer tests by root determination of the one-dimensional advection-dispersion equation (ADE) using a preset average tracer concentration which provides a theoretical basis for an estimate of necessary tracer mass. The method uses basic measured field parameters (e.g., discharge, distance, cross-sectional area) that are combined in functional relatipnships that descrive solute-transport processes related to flow velocity and time of travel. These initial estimates for time of travel and velocity are then applied to a hypothetical continuous stirred tank reactor (CSTR) as an analog for the hydrological-flow system to develop initial estimates for tracer concentration, tracer mass, and axial dispersion. Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to be necessary for descri

  16. Evaluation of single- and dual-porosity models for reproducing the release of external and internal tracers from heterogeneous waste-rock piles.

    PubMed

    Blackmore, S; Pedretti, D; Mayer, K U; Smith, L; Beckie, R D

    2018-05-30

    Accurate predictions of solute release from waste-rock piles (WRPs) are paramount for decision making in mining-related environmental processes. Tracers provide information that can be used to estimate effective transport parameters and understand mechanisms controlling the hydraulic and geochemical behavior of WRPs. It is shown that internal tracers (i.e. initially present) together with external (i.e. applied) tracers provide complementary and quantitative information to identify transport mechanisms. The analysis focuses on two experimental WRPs, Piles 4 and Pile 5 at the Antamina Mine site (Peru), where both an internal chloride tracer and externally applied bromide tracer were monitored in discharge over three years. The results suggest that external tracers provide insight into transport associated with relatively fast flow regions that are activated during higher-rate recharge events. In contrast, internal tracers provide insight into mechanisms controlling solutes release from lower-permeability zones within the piles. Rate-limited diffusive processes, which can be mimicked by nonlocal mass-transfer models, affect both internal and external tracers. The sensitivity of the mass-transfer parameters to heterogeneity is higher for external tracers than for internal tracers, as indicated by the different mean residence times characterizing the flow paths associated with each tracer. The joint use of internal and external tracers provides a more comprehensive understanding of the transport mechanisms in WRPs. In particular, the tracer tests support the notion that a multi-porosity conceptualization of WRPs is more adequate for capturing key mechanisms than a dual-porosity conceptualization. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Accounting for pharmacokinetic differences in dual-tracer receptor density imaging.

    PubMed

    Tichauer, K M; Diop, M; Elliott, J T; Samkoe, K S; Hasan, T; St Lawrence, K; Pogue, B W

    2014-05-21

    Dual-tracer molecular imaging is a powerful approach to quantify receptor expression in a wide range of tissues by using an untargeted tracer to account for any nonspecific uptake of a molecular-targeted tracer. This approach has previously required the pharmacokinetics of the receptor-targeted and untargeted tracers to be identical, requiring careful selection of an ideal untargeted tracer for any given targeted tracer. In this study, methodology capable of correcting for tracer differences in arterial input functions, as well as binding-independent delivery and retention, is derived and evaluated in a mouse U251 glioma xenograft model using an Affibody tracer targeted to epidermal growth factor receptor (EGFR), a cell membrane receptor overexpressed in many cancers. Simulations demonstrated that blood, and to a lesser extent vascular-permeability, pharmacokinetic differences between targeted and untargeted tracers could be quantified by deconvolving the uptakes of the two tracers in a region of interest devoid of targeted tracer binding, and therefore corrected for, by convolving the uptake of the untargeted tracer in all regions of interest by the product of the deconvolution. Using fluorescently labeled, EGFR-targeted and untargeted Affibodies (known to have different blood clearance rates), the average tumor concentration of EGFR in four mice was estimated using dual-tracer kinetic modeling to be 3.9 ± 2.4 nM compared to an expected concentration of 2.0 ± 0.4 nM. However, with deconvolution correction a more equivalent EGFR concentration of 2.0 ± 0.4 nM was measured.

  18. Chemical Tracer Methods: Chapter 7

    USGS Publications Warehouse

    Healy, Richard W.

    2017-01-01

    Tracers have a wide variety of uses in hydrologic studies: providing quantitative or qualitative estimates of recharge, identifying sources of recharge, providing information on velocities and travel times of water movement, assessing the importance of preferential flow paths, providing information on hydrodynamic dispersion, and providing data for calibration of water flow and solute-transport models (Walker, 1998; Cook and Herczeg, 2000; Scanlon et al., 2002b). Tracers generally are ions, isotopes, or gases that move with water and that can be detected in the atmosphere, in surface waters, and in the subsurface. Heat also is transported by water; therefore, temperatures can be used to trace water movement. This chapter focuses on the use of chemical and isotopic tracers in the subsurface to estimate recharge. Tracer use in surface-water studies to determine groundwater discharge to streams is addressed in Chapter 4; the use of temperature as a tracer is described in Chapter 8.Following the nomenclature of Scanlon et al. (2002b), tracers are grouped into three categories: natural environmental tracers, historical tracers, and applied tracers. Natural environmental tracers are those that are transported to or created within the atmosphere under natural processes; these tracers are carried to the Earth’s surface as wet or dry atmospheric deposition. The most commonly used natural environmental tracer is chloride (Cl) (Allison and Hughes, 1978). Ocean water, through the process of evaporation, is the primary source of atmospheric Cl. Other tracers in this category include chlorine-36 (36Cl) and tritium (3H); these two isotopes are produced naturally in the Earth’s atmosphere; however, there are additional anthropogenic sources of them.

  19. A DNA Tracer System for Hydrological Environment Investigations.

    PubMed

    Liao, Renkuan; Yang, Peiling; Wu, Wenyong; Luo, Dan; Yang, Dayong

    2018-02-20

    To monitor and manage hydrological pollution effectively, tracing sources of pollutants is of great importance and also is in urgent need. A variety of tracers have been developed such as isotopes, silica, bromide, and dyes; however, practical limitations of these traditional tracers still exist such as lack of multiplexed, multipoint tracing and interference of background noise. To overcome these limitations, a new tracing system based on DNA nanomaterials, namely DNA tracer, has already been developed. DNA tracers possess remarkable advantages including sufficient species, specificity, environmental friendly, stable migration, and high sensitivity as well as allowing for multipoints tracing. In this review article, we introduce the molecular design, synthesis, protection and signal readout strategies of DNA tracers, compare the advantages and disadvantages of DNA tracer with traditional tracers, and summarize the-state-of-art applications in hydrological environment investigations. In the end, we provide our perspective on the future development of DNA tracers.

  20. Using the tracer-dilution discharge method to develop streamflow records for ice-affected streams in Colorado

    USGS Publications Warehouse

    Capesius, Joseph P.; Sullivan, Joseph R.; O'Neill, Gregory B.; Williams, Cory A.

    2005-01-01

    Accurate ice-affected streamflow records are difficult to obtain for several reasons, which makes the management of instream-flow water rights in the wintertime a challenging endeavor. This report documents a method to improve ice-affected streamflow records for two gaging stations in Colorado. In January and February 2002, the U.S. Geological Survey, in cooperation with the Colorado Water Conservation Board, conducted an experiment using a sodium chloride tracer to measure streamflow under ice cover by the tracer-dilution discharge method. The purpose of this study was to determine the feasibility of obtaining accurate ice-affected streamflow records by using a sodium chloride tracer that was injected into the stream. The tracer was injected at two gaging stations once per day for approximately 20 minutes for 25 days. Multiple-parameter water-quality sensors at the two gaging stations monitored background and peak chloride concentrations. These data were used to determine discharge at each site. A comparison of the current-meter streamflow record to the tracer-dilution streamflow record shows different levels of accuracy and precision of the tracer-dilution streamflow record at the two sites. At the lower elevation and warmer site, Brandon Ditch near Whitewater, the tracer-dilution method overestimated flow by an average of 14 percent, but this average is strongly biased by outliers. At the higher elevation and colder site, Keystone Gulch near Dillon, the tracer-dilution method experienced problems with the tracer solution partially freezing in the injection line. The partial freezing of the tracer contributed to the tracer-dilution method underestimating flow by 52 percent at Keystone Gulch. In addition, a tracer-pump-reliability test was conducted to test how accurately the tracer pumps can discharge the tracer solution in conditions similar to those used at the gaging stations. Although the pumps were reliable and consistent throughout the 25-day study period, the pumps underdischarged the tracer by 5.8-15.9 percent as compared to the initial pumping rate setting, which may explain some of the error in the tracer-dilution streamflow record as compared to current-meter streamflow record.

  1. Do GSM 900MHz signals affect cerebral blood circulation? A near-infrared spectrophotometry study

    NASA Astrophysics Data System (ADS)

    Wolf, Martin; Haensse, Daniel; Morren, Geert; Froehlich, Juerg

    2006-06-01

    Effects of GSM 900MHz signals (EMF) typical for a handheld mobile phone on the cerebral blood circulation were investigated using near-infrared spectrophotometry (NIRS) in a three armed (12W/kg, 1.2W/kg, sham), double blind, randomized crossover trial in 16 healthy volunteers. During exposure we observed borderline significant short term responses of oxyhemoglobin and deoxyhemoglobin concentration, which correspond to a decrease of cerebral blood flow and volume and were smaller than regular physiological changes. Due to the relatively high number of statistical tests, these responses may be spurious and require further studies. There was no detectable dose-response relation or long term response within 20min. The detection limit was a fraction of the regular physiological changes elicited by functional activation. Compared to previous studies using PET, NIRS provides a much higher time resolution, which allowed investigating the short term effects efficiently, noninvasively, without the use of radioactive tracers and with high sensitivity.

  2. Validation of a Simulation Model of Intrinsic Lutetium-176 Activity in LSO-Based Preclinical PET Systems

    NASA Astrophysics Data System (ADS)

    McIntosh, Bryan

    The LSO scintillator crystal commonly used in PET scanners contains a low level of intrinsic radioactivity due to a small amount of Lu-176. This is not usually a concern in routine scanning but can become an issue in small animal imaging, especially when imaging low tracer activity levels. Previously there had been no systematic validation of simulations of this activity; this thesis discusses the validation of a GATE model of intrinsic Lu-176 against results from a bench-top pair of detectors and a Siemens Inveon preclinical PET system. The simulation results matched those from the bench-top system very well, but did not agree as well with results from the complete Inveon system due to a drop-off in system sensitivity at low energies that was not modelled. With this validation the model can now be used with confidence to predict the effects of Lu-176 activity in future PET systems.

  3. Nuclear medicine and quantitative imaging research (quantitative studies in radiopharmaceutical science): Comprehensive progress report, April 1, 1986-December 31, 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooper, M.D.; Beck, R.N.

    1988-06-01

    This document describes several years research to improve PET imaging and diagnostic techniques in man. This program addresses the problems involving the basic science and technology underlying the physical and conceptual tools of radioactive tracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The overall objective of this program is to further the development and transfer of radiotracer methodology from basic theory to routine clinical practice in order that individual patients and society as a whole will receive the maximum net benefitmore » from the new knowledge gained. The focus of the research is on the development of new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility. The reports in the study were processed separately for the data bases. (TEM)« less

  4. Nuclear medicine and quantitative imaging research (instrumentation and quantitative methods of evaluation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beck, R.N.; Cooper, M.D.

    1990-09-01

    This report summarizes goals and accomplishments of the research program supported under DOE Grant No. FG02-86ER60418 entitled Instrumentation and Quantitative Methods of Evaluation, with R. Beck, P. I. and M. Cooper, Co-P.I. during the period January 15, 1990 through September 1, 1990. This program addresses the problems involving the basic science and technology underlying the physical and conceptual tools of radioactive tracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The overall objective of this program is to further the development andmore » transfer of radiotracer methodology from basic theory to routine clinical practice in order that individual patients and society as a whole will receive the maximum net benefit from the new knowledge gained. The focus of the research is on the development of new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility. 7 figs.« less

  5. Determination of Urea Permeability in Red Cells by Minimum Method

    PubMed Central

    Sha'afi, R. I.; Rich, G. T.; Mikulecky, D. C.; Solomon, A. K.

    1970-01-01

    A new method has been developed for measuring the permeability coefficient, ω, of small nonelectrolytes. The method depends upon a mathematical analysis of the time course of cell volume changes in the neighborhood of the minimum volume following addition of a permeating solute to an isosmolal buffer. Coefficients determined by the minimum volume method agree with those obtained using radioactive tracers. ω for urea in human red cells was found to decrease as the volume flow, Jv, into the cell increased. Such behavior is entirely unexpected for a single uniform rate-limiting barrier on the basis of the linear phenomenological equations derived from irreversible thermodynamics. However, the present findings are consonant with a complex membrane system consisting of a tight barrier on the outer face of the human red cell membrane and a somewhat less restrictive barrier behind it closer to the inner membrane face. A theoretical analysis of such a series model has been made which makes predictions consistent with the experimental findings. PMID:5435779

  6. Osmium isotopic tracing of atmospheric emissions from an aluminum smelter

    NASA Astrophysics Data System (ADS)

    Gogot, Julien; Poirier, André; Boullemant, Amiel

    2015-09-01

    We present for the first time the use of osmium isotopic composition as a tracer of atmospheric emissions from an aluminum smelter, where alumina (extracted from bauxite) is reduced through electrolysis into metallic aluminum using carbonaceous anodes. These anodes are consumed in the process; they are made of petroleum coke and pitch and have high Re/Os elementary ratio. Due to the relatively large geological age of their source material, their osmium shows a high content of radiogenic 187Os produced from in situ187Re radioactive decay. The radiogenic isotopic composition (187Os/188Os ∼ 2.5) of atmospheric particulate emissions from this smelter is different from that of other typical anthropogenic osmium sources (that come from ultramafic geological contexts with unradiogenic Os isotopes, e.g., 187Os/188Os < 0.2) and also different from average eroding continental crust 187Os/188Os ratios (ca. 1.2). This study demonstrates the capacity of osmium measurements to monitor particulate matter emissions from the Al-producing industry.

  7. Contribution to the Study of Phosphate Uptake (P$sup 32$) at the Level of the Thyroid, The Suprarenals, and Testicles after Administration of Epiphysis Hormone; CONTRIBUTION A L'ETUDE DE LA PHOSPHOCAPTATION (P$sup 52$) AU NIVEAU DE LA THYROIDE DES SURRENALES ET DES TESTICULES APRES ADMINISTRATION DE L'EPIPHYSE-HORMONE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Negosscou, I.; Bojinescuu, Al.; Cocou, Fl.

    1959-10-31

    The phosphorus uptake by several endocrine glands after the administration of epiphysis hormone was studied by a tracer technique. After ten days of daily injections of the hormone into male albino rats, the rats received an injection of P/sup 32/. The hormone was again given 6, 12, and 18 hours after the P/sup 32/ injection. Some animals were killed 8 hours after the administration of phosphorus and the rest after 24 hours. The radioactivity of the epiphysis, hypophysis, thyroid, suprarenals, testicles, and seminal vesicles was determined. The results showed a functional inhibition of the phosphorus uptake in the thyroid, suprarenals,more » testicles, and seminal vesicles. A decrease in the phosphorus uptake by the hypophysis was also observed. (J.S.R.)« less

  8. Direct Parametric Image Reconstruction in Reduced Parameter Space for Rapid Multi-Tracer PET Imaging.

    PubMed

    Cheng, Xiaoyin; Li, Zhoulei; Liu, Zhen; Navab, Nassir; Huang, Sung-Cheng; Keller, Ulrich; Ziegler, Sibylle; Shi, Kuangyu

    2015-02-12

    The separation of multiple PET tracers within an overlapping scan based on intrinsic differences of tracer pharmacokinetics is challenging, due to limited signal-to-noise ratio (SNR) of PET measurements and high complexity of fitting models. In this study, we developed a direct parametric image reconstruction (DPIR) method for estimating kinetic parameters and recovering single tracer information from rapid multi-tracer PET measurements. This is achieved by integrating a multi-tracer model in a reduced parameter space (RPS) into dynamic image reconstruction. This new RPS model is reformulated from an existing multi-tracer model and contains fewer parameters for kinetic fitting. Ordered-subsets expectation-maximization (OSEM) was employed to approximate log-likelihood function with respect to kinetic parameters. To incorporate the multi-tracer model, an iterative weighted nonlinear least square (WNLS) method was employed. The proposed multi-tracer DPIR (MTDPIR) algorithm was evaluated on dual-tracer PET simulations ([18F]FDG and [11C]MET) as well as on preclinical PET measurements ([18F]FLT and [18F]FDG). The performance of the proposed algorithm was compared to the indirect parameter estimation method with the original dual-tracer model. The respective contributions of the RPS technique and the DPIR method to the performance of the new algorithm were analyzed in detail. For the preclinical evaluation, the tracer separation results were compared with single [18F]FDG scans of the same subjects measured 2 days before the dual-tracer scan. The results of the simulation and preclinical studies demonstrate that the proposed MT-DPIR method can improve the separation of multiple tracers for PET image quantification and kinetic parameter estimations.

  9. Application of separable parameter space techniques to multi-tracer PET compartment modeling.

    PubMed

    Zhang, Jeff L; Michael Morey, A; Kadrmas, Dan J

    2016-02-07

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg-Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models.

  10. Application of separable parameter space techniques to multi-tracer PET compartment modeling

    NASA Astrophysics Data System (ADS)

    Zhang, Jeff L.; Morey, A. Michael; Kadrmas, Dan J.

    2016-02-01

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg-Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models.

  11. Across North America tracer experiment (ANATEX): Sampling and analysis

    NASA Astrophysics Data System (ADS)

    Draxler, R. R.; Dietz, R.; Lagomarsino, R. J.; Start, G.

    Between 5 January 1987 and 29 March 1987, there were 33 releases of different tracers from each of two sites: Glasgow, MT and St. Cloud, MN. The perfluorocarbon tracers were routinely released in a 3-h period every 2.5 days, alternating between daytime and night-time tracer releases. Ground-level air samples of 24-h duration were taken at 77 sites mostly located near rawinsonde stations east of 105°W and between 26°N and 55°N. Weekly air samples were taken at 12 remote sites between San Diego, CA and Pt. Barrow, AK and between Norway and the Canary Islands. Short-term 6-h samples were collected at ground level and 200 m AGL along an arc of five towers between Tulsa, OK and Green Bay, WI. Aircraft sampling within several hundred kilometers of both tracer release sites was used to establish the initial tracer path. Experimental design required improved sampler performance, new tracers with lower atmospheric backgrounds, and improvements in analytic precision. The advances to the perfluorocarbon tracer system are discussed in detail. Results from the tracer sampling showed that the average and peak concentrations measured over the daily ground-level sampling network were consistent with what would be calculated using mass conservative approaches. however, ground-level samples from individual tracer patterns showed considerable complexity due to vertical stability or the interaction of the tracer plumes with low pressure and frontal systems. These systems could pass right through the tracer plume without appreciable effect. Aircraft tracer measurements are used to confirm the initial tracer trajectory when the narrow plume may miss the coarser spaced ground-level sampling network. Tower tracer measurements showed a more complex temporal structure than evident from the longer duration ground-level sampling sites. Few above background plume measurements were evident in the more distant remote sampling network due to larger than expected uncertainties in the ambient background concentrations.

  12. On the pathways and timescales of intercontinental air pollution transport

    NASA Astrophysics Data System (ADS)

    Stohl, Andreas; Eckhardt, Sabine; Forster, Caroline; James, Paul; Spichtinger, Nicole

    2002-12-01

    This paper presents results of a 1-year simulation of the transport of six passive tracers, released over the continents according to an emission inventory for carbon monoxide (CO). Lagrangian concepts are introduced to derive age spectra of the tracer concentrations on a global grid in order to determine the timescales and pathways of pollution export from the continents. Calculating these age spectra is equivalent to simulating many (quasi continuous) plumes, each starting at a different time, which are subsequently merged. Movies of the tracer dispersion have been made available on an Internet website. It is found that emissions from Asia experience the fastest vertical transport, whereas European emissions have the strongest tendency to remain in the lower troposphere. European emissions are transported primarily into the Arctic and appear to be the major contributor to the Arctic haze problem. Tracers from an upwind continent first arrive over a receptor continent in the upper troposphere, typically after some 4 days. Only later foreign tracers also arrive in the lower troposphere. Assuming a 2-day lifetime, the domestic tracers dominate total tracer columns over all continents except over Australia where foreign tracers account for 20% of the tracer mass. In contrast, for a 20-day lifetime even continents with high domestic emissions receive more than half of their tracer burden from foreign continents. Three special regions were identified where tracers are transported to, and tracer dilution is slow. Future field studies therefore should be deployed in the following regions: (1) In the winter, the Asia tracer accumulates over Indonesia and the Indian Ocean, a region speculated to be a stratospheric fountain. (2) In the summer, the highest concentrations of the Asia tracer are found in the Middle East. (3) In the summer, the highest concentrations of the North America tracer are found in the Mediterranean.

  13. Biological tracer method

    DOEpatents

    Strong-Gunderson, Janet M.; Palumbo, Anthony V.

    1998-01-01

    The present invention is a biological tracer method for characterizing the movement of a material through a medium, comprising the steps of: introducing a biological tracer comprising a microorganism having ice nucleating activity into a medium; collecting at least one sample of the medium from a point removed from the introduction point; and analyzing the sample for the presence of the biological tracer. The present invention is also a method for using a biological tracer as a label for material identification by introducing a biological tracer having ice nucleating activity into a material, collecting a sample of a portion of the labelled material and analyzing the sample for the presence of the biological tracer.

  14. Biological tracer method

    DOEpatents

    Strong-Gunderson, J.M.; Palumbo, A.V.

    1998-09-15

    The present invention is a biological tracer method for characterizing the movement of a material through a medium, comprising the steps of: introducing a biological tracer comprising a microorganism having ice nucleating activity into a medium; collecting at least one sample of the medium from a point removed from the introduction point; and analyzing the sample for the presence of the biological tracer. The present invention is also a method for using a biological tracer as a label for material identification by introducing a biological tracer having ice nucleating activity into a material, collecting a sample of a portion of the labelled material and analyzing the sample for the presence of the biological tracer. 2 figs.

  15. Estimates of tracer-based piston-flow ages of groundwater from selected sites-National Water-Quality Assessment Program, 1992-2005

    USGS Publications Warehouse

    Hinkle, Stephen R.; Shapiro, Stephanie D.; Plummer, Niel; Busenberg, Eurybiades; Widman, Peggy K.; Casile, Gerolamo C.; Wayland, Julian E.

    2011-01-01

    This report documents selected age data interpreted from measured concentrations of environmental tracers in groundwater from 1,399 National Water-Quality Assessment (NAWQA) Program groundwater sites across the United States. The tracers of interest were chlorofluorocarbons (CFCs), sulfur hexafluoride (SF6), and tritium/helium-3 (3H/3He). Tracer data compiled for this analysis primarily were from wells representing two types of NAWQA groundwater studies - Land-Use Studies (shallow wells, usually monitoring wells, in recharge areas under dominant land-use settings) and Major-Aquifer Studies (wells, usually domestic supply wells, in principal aquifers and representing the shallow, used resource). Reference wells (wells representing groundwater minimally impacted by anthropogenic activities) associated with Land-Use Studies also were included. Tracer samples were collected between 1992 and 2005, although two networks sampled from 2006 to 2007 were included because of network-specific needs. Tracer data from other NAWQA Program components (Flow System Studies, which are assessments of processes and trends along groundwater flow paths, and various topical studies) were not compiled herein. Tracer data from NAWQA Land-Use Studies and Major-Aquifer Studies that previously had been interpreted and published are compiled herein (as piston-flow ages), but have not been reinterpreted. Tracer data that previously had not been interpreted and published are evaluated using documented methods and compiled with aqueous concentrations, equivalent atmospheric concentrations (for CFCs and SF6), estimates of tracer-based piston-flow ages, and selected ancillary data, such as redox indicators, well construction, and major dissolved gases (N2, O2, Ar, CH4, and CO2). Tracer-based piston-flow ages documented in this report are simplistic representations of the tracer data. Tracer-based piston-flow ages are a convenient means of conceptualizing groundwater age. However, the piston-flow model is based on the potentially limiting assumptions that tracer transport is advective and that no mixing occurs. Additional uncertainties can arise from tracer degradation, sorption, contamination, or fractionation; terrigenic (natural) sources of tracers; spatially variable atmospheric tracer concentrations; and incomplete understanding of mechanisms of recharge or of the conditions under which atmospheric tracers were partitioned to recharge. The effects of some of these uncertainties are considered herein. For example, degradation, contamination, or fractionation often can be identified or inferred. However, detailed analysis of the effects of such uncertainties on the tracer-based piston-flow ages is constrained by sparse data and an absence of complementary lines of evidence, such as detailed solute transport simulations. Thus, the tracer-based piston-flow ages compiled in this report represent only an initial interpretation of the tracer data.

  16. Lanthanide-labeled clay: A new method for tracing sediment transport in Karst

    USGS Publications Warehouse

    Mahler, B.J.; Bennett, P.C.; Zimmerman, M.

    1998-01-01

    Mobile sediment is a fundamental yet poorly characterized aspect of mass transport through karst aquifers. Here the development and field testing of an extremely sensitive particle tracer that may be used to characterize sediment transport in karst aquifers is described. The tracer consists of micron-size montmorillonite particles homoionized to the lanthanide form; after injection and retrieval from a ground water system, the lanthanide ions are chemically stripped from the clay and quantified by high performance liquid chromatography. The tracer meets the following desired criteria: low detection limit; a number of differentiable signatures; inexpensive production and quantification using standard methods; no environmental risks; and hydrodynamic properties similar to the in situ sediment it is designed to trace. The tracer was tested in laboratory batch experiments and field tested in both surface water and ground water systems. In surface water, arrival times of the tracer were similar to those of a conservative water tracer, although a significant amount of material was lost due to settling. Two tracer tests were undertaken in a karst aquifer under different flow conditions. Under normal flow conditions, the time of arrival and peak concentration of the tracer were similar to or preceded that of a conservative water tracer. Under low flow conditions, the particle tracer was not detected, suggesting that in low flow the sediment settles out of suspension and goes into storage.Mobile sediment is a fundamental yet poorly characterized aspect of mass transport through karst aquifers. Here the development and field testing of an extremely sensitive particle tracer that may be used to characterize sediment transport in karst aquifers is described. The tracer consists of micron-size montmorillonite particles homoionized to the lanthanide form; after injection and retrieval from a ground water system, the lanthanide ions are chemically stripped from the clay and quantified by high performance liquid chromatography. The tracer meets the following desired criteria: low detection limit; a number of differentiable signatures; inexpensive production and quantification using standard methods; no environmental risks; and hydrodynamic properties similar to the in situ sediment it is designed to trace. The tracer was tested in laboratory batch experiments and field tested in both surface water and ground water systems. In surface water, arrival times of the tracer were similar to those of a conservative water tracer, although a significant amount of material was lost due to settling. Two tracer tests were undertaken in a karst aquifer under different flow conditions. Under normal flow conditions, the time of arrival and peak concentration of the tracer were similar to or preceded that of a conservative water tracer. Under low flow conditions, the particle tracer was not detected, suggesting that in low flow the sediment settles out of suspension and goes into storage.

  17. Emission quantification using the tracer gas dispersion method: The influence of instrument, tracer gas species and source simulation.

    PubMed

    Delre, Antonio; Mønster, Jacob; Samuelsson, Jerker; Fredenslund, Anders M; Scheutz, Charlotte

    2018-09-01

    The tracer gas dispersion method (TDM) is a remote sensing method used for quantifying fugitive emissions by relying on the controlled release of a tracer gas at the source, combined with concentration measurements of the tracer and target gas plumes. The TDM was tested at a wastewater treatment plant for plant-integrated methane emission quantification, using four analytical instruments simultaneously and four different tracer gases. Measurements performed using a combination of an analytical instrument and a tracer gas, with a high ratio between the tracer gas release rate and instrument precision (a high release-precision ratio), resulted in well-defined plumes with a high signal-to-noise ratio and a high methane-to-tracer gas correlation factor. Measured methane emission rates differed by up to 18% from the mean value when measurements were performed using seven different instrument and tracer gas combinations. Analytical instruments with a high detection frequency and good precision were established as the most suitable for successful TDM application. The application of an instrument with a poor precision could only to some extent be overcome by applying a higher tracer gas release rate. A sideward misplacement of the tracer gas release point of about 250m resulted in an emission rate comparable to those obtained using a tracer gas correctly simulating the methane emission. Conversely, an upwind misplacement of about 150m resulted in an emission rate overestimation of almost 50%, showing the importance of proper emission source simulation when applying the TDM. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Tracer-Test Planning Using the Efficient Hydrologic Tracer ...

    EPA Pesticide Factsheets

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed that combines basic measured field parameters (e.g., discharge, distance, cross-sectional area) in functional relationships that describe solute-transport processes related to flow velocity and time of travel. The new method applies these initial estimates for time of travel and velocity to a hypothetical continuously stirred tank reactor as an analog for the hydrologic flow system to develop initial estimates for tracer concentration and axial dispersion, based on a preset average tracer concentration. Root determination of the one-dimensional advection-dispersion equation (ADE) using the preset average tracer concentration then provides a theoretical basis for an estimate of necessary tracer mass.Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to be

  19. Journal: A Review of Some Tracer-Test Design Equations for ...

    EPA Pesticide Factsheets

    Determination of necessary tracer mass, initial sample-collection time, and subsequent sample-collection frequency are the three most difficult aspects to estimate for a proposed tracer test prior to conducting the tracer test. To facilitate tracer-mass estimation, 33 mass-estimation equations are reviewed here, 32 of which were evaluated using previously published tracer-test design examination parameters. Comparison of the results produced a wide range of estimated tracer mass, but no means is available by which one equation may be reasonably selected over the others. Each equation produces a simple approximation for tracer mass. Most of the equations are based primarily on estimates or measurements of discharge, transport distance, and suspected transport times. Although the basic field parameters commonly employed are appropriate for estimating tracer mass, the 33 equations are problematic in that they were all probably based on the original developers' experience in a particular field area and not necessarily on measured hydraulic parameters or solute-transport theory. Suggested sampling frequencies are typically based primarily on probable transport distance, but with little regard to expected travel times. This too is problematic in that tends to result in false negatives or data aliasing. Simulations from the recently developed efficient hydrologic tracer-test design methodology (EHTD) were compared with those obtained from 32 of the 33 published tracer-

  20. Test of synthetic DNA tracers in a periodic hydrodynamic system for time-variable transit time distribution assessment

    NASA Astrophysics Data System (ADS)

    Dahlke, H. E.; Wang, C.; McNew, C.; McLaughlin, S.; Lyon, S. W.

    2016-12-01

    Recent research on time-varying transport through hydrologic systems proposed using decomposed over-printed tracer breakthrough curves to directly observe transport through complex flow systems. This method, also known as the PERTH (Periodic Tracer Hierarchy) method requires periodic flow and multiple tracer injections to reveal changes in flow pathways and transport behavior. Time-variable transit time distributions (TTD) estimated from tracer breakthrough curves often vary with the storage state of the system, which in turn is influenced by internal and external variabilities, such as the arrangement of flow pathways and fluctuations in system inputs. Deciphering internal from external variabilities in TTDs might help to advance the use of TTDs for estimating the physical state of a system; however, thus far the finite number of unique conservative tracers available for tracing has limited deeper insights. Synthetic DNA tracers consisting of short strands of synthetic DNA encapsulated by polylactic acid (PLA) microspheres could potentially provide multiple unique tracers with identical transport properties needed to explore time varying transport through hydrologic systems in more detail. An experiment was conducted on the miniLeo hillslope, a 1 m3 sloping lysimeter, within the Biosphere 2 Landscape Evolution Observatory near Tucson, AZ to investigate transit time variability. The goal of the experiment was to 1) test the suitability of using synthetic DNA tracers for estimating TTDs in a hydrologic system and 2) to determine the TTDs of individual tracer pulses under periodic steady-state conditions. Five DNA tracers, consisting of four unique, encapsulated DNA sequences and one free/non-encapsulated DNA sequence, were applied as reference and probe tracers together with deuterium, using the PERTH method. The lysimeter received three 2-hour pulses of rainfall at a rate of 30 mm/hr for 10 days. Initial results show that both the encapsulated and free DNA tracers were successfully transported in a pulsed manner through the system, but had overall longer breakthrough times than the reference deuterium tracer. Comparison of the DNA probe tracers indicate differences in transit times, likely related to differences in tracer mobilization in response to the time-variant rainfall input.

  1. Technical Note: Coupling of chemical processes with the Modular Earth Submodel System (MESSy) submodel TRACER

    NASA Astrophysics Data System (ADS)

    Jöckel, P.; Kerkweg, A.; Buchholz-Dietsch, J.; Tost, H.; Sander, R.; Pozzer, A.

    2008-03-01

    The implementation of processes related to chemistry into Earth System Models and their coupling within such systems requires the consistent description of the chemical species involved. We provide a tool (written in Fortran95) to structure and manage information about constituents, hereinafter referred to as tracers, namely the Modular Earth Submodel System (MESSy) generic (i.e., infrastructure) submodel TRACER. With TRACER it is possible to define a multitude of tracer sets, depending on the spatio-temporal representation (i.e., the grid structure) of the model. The required information about a specific chemical species is split into the static meta-information about the characteristics of the species, and its (generally in time and space variable) abundance in the corresponding representation. TRACER moreover includes two submodels. One is TRACER_FAMILY, an implementation of the tracer family concept. It distinguishes between two types: type-1 families are usually applied to handle strongly related tracers (e.g., fast equilibrating species) for a specific process (e.g., advection). In contrast to this, type-2 families are applied for tagging techniques. Tagging means the artificial decomposition of one or more species into parts, which are additionally labelled (e.g., by the region of their primary emission) and then processed as the species itself. The type-2 family concept is designed to conserve the linear relationship between the family and its members. The second submodel is TRACER_PDEF, which corrects and budgets numerical negative overshoots that arise in many process implementations due to the numerical limitations (e.g., rounding errors). The submodel therefore guarantees the positive definiteness of the tracers and stabilises the integration scheme. As a by-product, it further provides a global tracer mass diagnostic. Last but not least, we present the submodel PTRAC, which allows the definition of tracers via a Fortran95 namelist, as a complement to the standard tracer definition by application of the TRACER interface routines in the code. TRACER with its submodels and PTRAC can readily be applied to a variety of models without further requirements. The code and a documentation are included in the electronic supplement.

  2. LARGE-SCALE NATURAL GRADIENT TRACER TEST IN SAND AND GRAVEL, CAPE COD, MASSACHUSETTS - 1. EXPERIMENTAL DESIGN AND OBSERVED TRACER MOVEMENT

    EPA Science Inventory

    A large-scale natural gradient tracer experiment was conducted on Cape Cod, Massachusetts, to examine the transport and dispersion of solutes in a sand and gravel aquifer. The nonreactive tracer, bromide, and the reactive tracers, lithium and molybdate, were injected as a pulse i...

  3. Tuning structure and mobility of solvation shells surrounding tracer additives.

    PubMed

    Carmer, James; Jain, Avni; Bollinger, Jonathan A; van Swol, Frank; Truskett, Thomas M

    2015-03-28

    Molecular dynamics simulations and a stochastic Fokker-Planck equation based approach are used to illuminate how position-dependent solvent mobility near one or more tracer particle(s) is affected when tracer-solvent interactions are rationally modified to affect corresponding solvation structure. For tracers in a dense hard-sphere fluid, we compare two types of tracer-solvent interactions: (1) a hard-sphere-like interaction, and (2) a soft repulsion extending beyond the hard core designed via statistical mechanical theory to enhance tracer mobility at infinite dilution by suppressing coordination-shell structure [Carmer et al., Soft Matter 8, 4083-4089 (2012)]. For the latter case, we show that the mobility of surrounding solvent particles is also increased by addition of the soft repulsive interaction, which helps to rationalize the mechanism underlying the tracer's enhanced diffusivity. However, if multiple tracer surfaces are in closer proximity (as at higher tracer concentrations), similar interactions that disrupt local solvation structure instead suppress the position-dependent solvent dynamics.

  4. Asian Tracer Experiment and Atmospheric Modeling (TEAM) Project: Draft Field Work Plan for the Asian Long-Range Tracer Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allwine, K Jerry; Flaherty, Julia E.

    2007-08-01

    This report provides an experimental plan for a proposed Asian long-range tracer study as part of the international Tracer Experiment and Atmospheric Modeling (TEAM) Project. The TEAM partners are China, Japan, South Korea and the United States. Optimal times of year to conduct the study, meteorological measurements needed, proposed tracer release locations, proposed tracer sampling locations and the proposed durations of tracer releases and subsequent sampling are given. Also given are the activities necessary to prepare for the study and the schedule for completing the preparation activities leading to conducting the actual field operations. This report is intended to providemore » the TEAM members with the information necessary for planning and conducting the Asian long-range tracer study. The experimental plan is proposed, at this time, to describe the efforts necessary to conduct the Asian long-range tracer study, and the plan will undoubtedly be revised and refined as the planning goes forward over the next year.« less

  5. The fluorescent tracer experiment on Holiday Beach near Mugu Canyon, Southern California

    USGS Publications Warehouse

    Kinsman, Nicole; Xu, J. P.

    2012-01-01

    After revisiting sand tracer techniques originally developed in the 1960s, a range of fluorescent coating formulations were tested in the laboratory. Explicit steps are presented for the preparation of the formulation evaluated to have superior attributes, a thermoplastic pigment/dye in a colloidal mixture with a vinyl chloride/vinyl acetate copolymer. In September 2010, 0.59 cubic meters of fluorescent tracer material was injected into the littoral zone about 4 kilometers upcoast of Mugu submarine canyon in California. The movement of tracer was monitored in three dimensions over the course of 4 days using manual and automated techniques. Detailed observations of the tracer's behavior in the coastal zone indicate that this tracer successfully mimicked the native beach sand and similar methods could be used to validate models of tracer movement in this type of environment. Recommendations including how to time successful tracer studies and how to scale the field of view of automated camera systems are presented along with the advantages and disadvantages of the described tracer methodology.

  6. Non-universal tracer diffusion in crowded media of non-inert obstacles.

    PubMed

    Ghosh, Surya K; Cherstvy, Andrey G; Metzler, Ralf

    2015-01-21

    We study the diffusion of a tracer particle, which moves in continuum space between a lattice of excluded volume, immobile non-inert obstacles. In particular, we analyse how the strength of the tracer-obstacle interactions and the volume occupancy of the crowders alter the diffusive motion of the tracer. From the details of partitioning of the tracer diffusion modes between trapping states when bound to obstacles and bulk diffusion, we examine the degree of localisation of the tracer in the lattice of crowders. We study the properties of the tracer diffusion in terms of the ensemble and time averaged mean squared displacements, the trapping time distributions, the amplitude variation of the time averaged mean squared displacements, and the non-Gaussianity parameter of the diffusing tracer. We conclude that tracer-obstacle adsorption and binding triggers a transient anomalous diffusion. From a very narrow spread of recorded individual time averaged trajectories we exclude continuous type random walk processes as the underlying physical model of the tracer diffusion in our system. For moderate tracer-crowder attraction the motion is found to be fully ergodic, while at stronger attraction strength a transient disparity between ensemble and time averaged mean squared displacements occurs. We also put our results into perspective with findings from experimental single-particle tracking and simulations of the diffusion of tagged tracers in dense crowded suspensions. Our results have implications for the diffusion, transport, and spreading of chemical components in highly crowded environments inside living cells and other structured liquids.

  7. Application of separable parameter space techniques to multi-tracer PET compartment modeling

    PubMed Central

    Zhang, Jeff L; Morey, A Michael; Kadrmas, Dan J

    2016-01-01

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg–Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models. PMID:26788888

  8. Tracer tomography: design concepts and field experiments using heat as a tracer.

    PubMed

    Doro, Kennedy O; Cirpka, Olaf A; Leven, Carsten

    2015-04-01

    Numerical and laboratory studies have provided evidence that combining hydraulic tomography with tomographic tracer tests could improve the estimation of hydraulic conductivity compared with using hydraulic data alone. Field demonstrations, however, have been lacking so far, which we attribute to experimental difficulties. In this study, we present a conceptual design and experimental applications of tracer tomography at the field scale using heat as a tracer. In our experimental design, we improve active heat tracer testing by minimizing possible effects of heat losses, buoyancy, viscosity, and changing boundary conditions. We also utilize a cost-effective approach of measuring temperature changes in situ at high resolution. We apply the presented method to the 8 m thick heterogeneous, sandy gravel, alluvial aquifer at the Lauswiesen Hydrogeological Research Site in Tübingen, Germany. Results of our tomographic heat-tracer experiments are in line with earlier work on characterizing the aquifer at the test site. We demonstrate from the experimental perspective that tracer tomography is applicable and suitable at the field scale using heat as a tracer. The experimental results also demonstrate the potential of heat-tracer tomography as a cost-effective means for characterizing aquifer heterogeneity. © 2014, National Ground Water Association.

  9. COMPARISON OF THREE TRACER TESTS AT THE RAFT RIVER GEOTHERMAL SITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Earl D Mattson; Mitchell Plummer; Carl Palmer

    2011-02-01

    Three conservative tracer tests have been conducted through the Bridge Fault fracture zone at the Raft River Geothermal (RRG) site. All three tests were conducted between injection well RRG-5 and production wells RRG-1 (790 m distance) and RRG-4 (740 m distance). The injection well is used during the summer months to provide pressure support to the production wells. The first test was conducted in 2008 using 136 kg of fluorescein tracer. Two additional tracers were injected in 2010. The first 2010 tracer injected was 100 kg fluorescein disodium hydrate salt on June, 21. The second tracer (100 kg 2,6-naphthalene disulfonicmore » acid sodium salt) was injected one month later on July 21. Sampling of the two productions wells is still being performed to obtain the tail end of the second 2010 tracer test. Tracer concentrations were measured using HPLC with a fluorescence detector. Results for the 2008 test, suggest 80% tracer recover at the two production wells. Of the tracer recovered, 85% of tracer mass was recovered in well RRG-4 indicating a greater flow pathway connection between injection well and RRG-4 than RRG-1. Fluorescein tracer results appear to be similar between the 2008 and 2010 tests for well RRG-4 with peak concentrations arriving approximately 20 days after injection despite the differences between the injection rates for the two tests (~950 gpm to 475 gpm) between the 2008 and 2010. The two 2010 tracer tests will be compared to determine if the results support the hypothesis that rock contraction along the flow pathway due to the 55 oC cooler water injection alters the flow through the ~140 oC reservoir.« less

  10. Application of multiple tracers (SF6 and chloride) to identify the transport by characteristics of contaminant at two separate contaminated sites

    NASA Astrophysics Data System (ADS)

    Lee, K. K.; Lee, S. S.; Kim, H. H.; Koh, E. H.; Kim, M. O.; Lee, K.; Kim, H. J.

    2016-12-01

    Multiple tracers were applied for source and pathway detection at two different sites. CO2 gas injected in the subsurface for a shallow-depth CO2 injection and leak test can be regarded as a potential contaminant source. Therefore, it is necessary to identify the migration pattern of CO2 gas. Also, at a DNAPL contaminated site, it is important to figure out the characteristics of plume evolution from the source zone. In this study, multiple tracers (SF6 and chloride) were used to evaluate the applicability of volatile and non-volatile tracers and to identify the characteristics of contaminant transport at each CO2 injection and leak test site and DNAPL contaminated site. Firstly, at the CO2 test site, multiple tracers were used to perform the single well push-drift-pull tracer test at total 3 specific depth zones. As results of tests, volatile and non-volatile tracers showed different mass recovery percentage. Most of chloride mass was recovered but less than half of SF6 mass was recovered due to volatile property. This means that only gaseous SF6 leak out to unsaturated zone. However, breakthrough curves of both tracers indicated similar peak time, effective porosity, and regional groundwater velocity. Also, at both contaminated sites, natural gradient tracer tests were performed with multiple tracers. With the results of natural gradient tracer test, it was possible to confirm the applicability of multiple tracers and to understand the contaminant transport in highly heterogeneous aquifer systems through the long-term monitoring of tracers. Acknowledgement: financial support was provided by the R&D Project on Environmental Management of Geologic CO2 Storage)" from the KEITI (Project Number: 2014001810003) and Korea Ministry of Environment as "The GAIA project (2014000540010)".

  11. Global atmospheric monitoring of noble gases: insight into transport processes in the southern hemisphere.

    NASA Astrophysics Data System (ADS)

    Kusmierczyk-Michulec, J.; Kalinowski, M.; Bourgouin, P.; Schoeppner, M.

    2017-12-01

    The International Monitoring System (IMS) developed by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) is a global system of monitoring stations, using four complementary technologies: seismic, hydroacoustic, infrasound and radionuclide. Data from all stations, belonging to IMS, are collected and transmitted to the International Data Centre (IDC) in Vienna, Austria. The radionuclide network comprises 80 stations, of which 31 stations are located in the Southern Hemisphere. The aim of radionuclide stations is a global monitoring of radioactive aerosols and radioactive noble gases supported by atmospheric transport modeling (ATM). The air mass trajectory provides a "link" between a radionuclide release and a detection confirmed by radionuclide measurements. One of the important noble gases, monitored on a daily basis, is xenon. It can be produced either during a nuclear explosion with a high fission yield, and thus be considered as an important tracer to prove the nuclear character of an explosion, or be emitted from nuclear power plants (NPPs) or from isotope production facilities (IPFs). On the southern hemisphere the number of IPF is rather limited in comparison to the northern hemisphere. Among the major sources are: the ANSTO facility in Sydney (Australia), CNEA in Ezeiza (Argentina), BaTek/INUKI in Jakarta (Indonesia) and NECSA in Pelindaba (South Africa). This study will demonstrate the examples of seasonal contribution of Xe-133 emissions from major sources as observed at selected IMS stations located in the southern hemisphere. It will show as well examples of the atmospheric transport from the northern to the southern hemisphere, and the influence of strong atmospheric convection.

  12. Concentration of Uranium Radioisotopes in Albanian Drinking Waters Measured by Alpha Spectrometry

    NASA Astrophysics Data System (ADS)

    Bylyku, Elida; Cfarku, Florinda; Deda, Antoneta; Bode, Kozeta; Fishka, Kujtim

    2010-01-01

    Uranium is a radioactive material that is frequently found in rocks and soil. When uranium decays, it changes into different elements that are also radioactive, including radon, a gas that is known to cause a lung cancer. The main concern with uranium in drinking water is harm to the kidneys. Public water systems are required to keep uranium levels at or below 500 mBq per liter to protect against kidney damage. Such an interest is needed due to safety, regulatory compliance and disposal issue for uranium in the environment since uranium is included as an obligatory controlled radionuclide in the European Legislation (Directive 98/83 CE of Council of 03.11.1998). The aim of this work is to measure the levels of uranium in drinking and drilled well waters in Albania. At first each sample was measured for total Alpha and total Beta activity. The samples with the highest levels of total alpha activity were chosen for the determination of uranium radioisotopes by alpha spectrometry. A radiochemical procedure using extraction with TBP (Tri-Butyl-Phosphate) is used in the presence of U232 as a yield tracer. Thin sources for alpha spectrometry are prepared by electrodepositing on to stainless steel discs. The results of the U238 activity measured in the different samples, depending from their geological origin range between 0.55-13.87 mBq/l. All samples measured results under the European Directive limits for U238 (5-500 mBq/1), Dose Coefficients according to Directive 96/29 EURATOM.

  13. Colloid facilitated transport of lanthanides through discrete fractures in chalk

    NASA Astrophysics Data System (ADS)

    Tran, Emily; Klein Ben-David, Ofra; Teutsch, Nadya; Weisbrod, Noam

    2015-04-01

    Geological disposal of high-level radioactive waste is the internationally agreed-upon, long term solution for the disposal of long lived radionuclides and spent fuel. Eventually, corrosion of the waste canisters may lead to leakage of their hazardous contents, and the radionuclides can ultimately make their way into groundwater and pose a threat to the biosphere. Engineered bentonite barriers placed around nuclear waste repositories are generally considered sufficient to impede the transport of radionuclides from their storage location to the groundwater. However, colloidal-sized mobile bentonite particles eroding from these barriers have come under investigation as a potential transport vector for radionuclides sorbed to them. In addition, the presence of organic matter in groundwater has been shown to additionally facilitate the uptake of radionuclides by the clay colloids. This study aims to evaluate the transport behaviors of radionuclides in colloid-facilitated transport through a fractured chalk matrix and under geochemical conditions representative of the Negev desert, Israel. Lanthanides are considered an acceptable substitute to actinides for research on radionuclide transportation due to their similar chemical behavior. In this study, the migration of Ce both with and without colloidal particles was explored and compared to the migration of a conservative tracer (bromide). Tracer solutions containing known concentrations of Ce, bentonite colloids, humic acid and bromide were prepared in a matrix solution containing salt concentrations representative of that of the average rain water found in the Negev. These solutions were then injected into a flow system constructed around a naturally fractured chalk core. Samples were analyzed for Ce and Br using ICP-MS, and colloid concentrations were determined using spectrophotographic analysis. Breakthrough curves comparing the rates of transportation of each tracer were obtained, allowing for comparison of transport rates and calculation of overall tracer recovery. Preliminary results suggest that mobility of Ce as a solute is negligible, and in experiments conducted without bentonite colloids, the 2% of the Ce that was recovered during the experiments travelled as "intrinsic" colloids in the form of Ce2(CO3)3-6H2O precipitate. However, the total recovery of the Ce increased to 9% when it was injected into the core in the presence of bentonite colloids and 13% when both bentonite and the carbonate precipitate colloids were injected. In addition, the maximum relative concentration (C/C0) of the Ce in the samples from the experiments conducted without bentonite colloids is about 0.002, whereas that of the experiments conducted in the presence of bentonite colloids reaches almost 0.2. This indicates that colloid presence does indeed markedly increase the mobility of radionuclides through fractured chalk matrices and should therefore be considered in models representing transport of radionuclide waste originating from nuclear repositories.

  14. BIOLOGICAL AND MEDICAL RESEARCH DIVISION SEMIANNUAL REPORT FOR JANUARY THROUGH JUNE 1958

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1958-09-01

    The hemolysin system in gamma-irradiated rabbits was used in a study of the qualitative as well as the quantitative characteristics of the radiosensitivity of antibody production. Applications of IBM equipment in the analysis of biological data are discussed. Cytological features are described which were obscrved in buckwheat grown in carton dioxide containing carbon14. Electron microscopic observations are described which were made on the ovotestis of a pulmonate snail and on ciliate nuclear phenomena in Tetrahymena. Results are reported from a study of the comparative carcinogenicity of radium-226, strontium-90, and calcium-45 in mice. Results of tracer studies on metabolism in culturesmore » of Escherichia coli indicate that in growing cultures of bacterias intracellular protein degradation and nucleic acid degradation do not occur and that under normal conditions cell death rarely occurs. Data on the heterologous growth of mouse ascites tumor in the rat are summarized. Observations on radiation injuries in chick embryos following exposure to cobalt-60 gamma radiation suggest two distinct modes of radiation injury. Findings are discussed. Progress is reported in the following studies: investigations of the heat-stable factor necessary for inhibition of catalase; the enzymatic decomposition of S- adenosylmethionine and methylthioadenosine; protein synthesis in the pancreas; the response of various mouse strains and hybrids to daily dosages of cobalt-60 gamma radiation; the effects of heavy water on kidneys and liver of rats; the effect of x radiation on the intracellular distribution of cytochrome oxidase in the rat thymus; the dependence of acute and subacute radiosensitivity on age in mice; the rate of recovery from radiation injury~; the effect of fractionation of dose on biological effects of fission neutrons; the relative biological cffectiveness of fission neutrons and cobalt-60 gamma radiation evaluated by 15 different biological tests on a widely varying group of plants and animals; the life-shortening effect of whole-body exposure to ionizing radiation in mice; the effectiveness of new chelating agents in the treatment of plutonium poisoning; the effects of radiotoxic levels of gamma-emitting isotopes on distribution and retention patterns established by tracer methods; the effects of ultraviolet radiation on amoebae; tracer studies on the life cycle of leukocytes; the dynamics of the release of histamine from tissue mast cells; the effect of repeated paracentesis on the growth of Ehrlich ascites tumor cells in mice; the effects of deuterium oxicie in drinking water on pregnancy and on viability of newbom mice; the radioactivity of grass grown on thorium-bearing sand; and tracer studies on the metabolism of proteins, fatty acidss and cholesterol. (For preceding period see ANL-5841.) (C.H.)« less

  15. Three-dimensional noninvasive monitoring iodine-131 uptake in the thyroid using a modified Cerenkov luminescence tomography approach.

    PubMed

    Hu, Zhenhua; Ma, Xiaowei; Qu, Xiaochao; Yang, Weidong; Liang, Jimin; Wang, Jing; Tian, Jie

    2012-01-01

    Cerenkov luminescence tomography (CLT) provides the three-dimensional (3D) radiopharmaceutical biodistribution in small living animals, which is vital to biomedical imaging. However, existing single-spectral and multispectral methods are not very efficient and effective at reconstructing the distribution of the radionuclide tracer. In this paper, we present a semi-quantitative Cerenkov radiation spectral characteristic-based source reconstruction method named the hybrid spectral CLT, to efficiently reconstruct the radionuclide tracer with both encouraging reconstruction results and less acquisition and image reconstruction time. We constructed the implantation mouse model implanted with a 400 µCi Na(131)I radioactive source and the physiological mouse model received an intravenous tail injection of 400 µCi radiopharmaceutical Iodine-131 (I-131) to validate the performance of the hybrid spectral CLT and compared the reconstruction results, acquisition, and image reconstruction time with that of single-spectral and multispectral CLT. Furthermore, we performed 3D noninvasive monitoring of I-131 uptake in the thyroid and quantified I-131 uptake in vivo using hybrid spectral CLT. Results showed that the reconstruction based on the hybrid spectral CLT was more accurate in localization and quantification than using single-spectral CLT, and was more efficient in the in vivo experiment compared with multispectral CLT. Additionally, 3D visualization of longitudinal observations suggested that the reconstructed energy of I-131 uptake in the thyroid increased with acquisition time and there was a robust correlation between the reconstructed energy versus the gamma ray counts of I-131 (r(2) = 0.8240). The ex vivo biodistribution experiment further confirmed the I-131 uptake in the thyroid for hybrid spectral CLT. Results indicated that hybrid spectral CLT could be potentially used for thyroid imaging to evaluate its function and monitor its treatment for thyroid cancer.

  16. Purdue University National Biomedical Tracer Facility: Project definition phase. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, M.A.

    The proposed National Biomedical Tracer Facility (NBTF) will house a high-current accelerator dedicated to production of short-lived radionuclides for biomedical and scientific research. The NBTF will play a vital role in repairing and maintaining the United States` research infrastructure for generation of essential accelerator-based radioisotopes. If properly designed and managed, the NBTF should also achieve international recognition as a Center-of-Excellence for research on radioisotope production methods and for associated education and training. The current report documents the results of a DOE-funded NBTF Project Definition Phase study carried out to better define the technical feasibility and projected costs of establishing andmore » operating the NBTF. This report provides an overview of recommended Facility Design and Specifications, including Accelerator Design, Building Design, and the associated Construction Cost Estimates and Schedule. It is recommended that the NBTF be established as an integrated, comprehensive facility for meeting the diverse production, research, and educational missions set forth in previous documents. Based on an analysis of the projected production demands that will be placed on the NBTF, it appears that a 70 MeV, 1 mA, negative ion cyclotron will offer a good balance between production capabilities and the costs of accelerator purchase and operation. A preliminary architectural plan is presented for a facility designed specifically to fulfill the functions of the NBTF in a cost-effective manner. This report also presents a detailed analysis of the Required Federal State, and Local Permits that may be needed to establish the NBTF, along with schedules and cost estimates for obtaining these permits. The Handling, Storage, and Disposal of Radioactive Waste will pose some significant challenges in the operation of the NBTF, but at this stage of planning the associated problems do not appear to be prohibitive.« less

  17. Dual-isotope PET using positron-gamma emitters.

    PubMed

    Andreyev, A; Celler, A

    2011-07-21

    Positron emission tomography (PET) is widely recognized as a highly effective functional imaging modality. Unfortunately, standard PET cannot be used for dual-isotope imaging (which would allow for simultaneous investigation of two different biological processes), because positron-electron annihilation products from different tracers are indistinguishable in terms of energy. Methods that have been proposed for dual-isotope PET rely on differences in half-lives of the participating isotopes; these approaches, however, require making assumptions concerning kinetic behavior of the tracers and may not lead to optimal results. In this paper we propose a novel approach for dual-isotope PET and investigate its performance using GATE simulations. Our method requires one of the two radioactive isotopes to be a pure positron emitter and the second isotope to emit an additional high-energy gamma in a cascade simultaneously with positron emission. Detection of this auxiliary prompt gamma in coincidence with the annihilation event allows us to identify the corresponding 511 keV photon pair as originating from the same isotope. Two list-mode datasets are created: a primary dataset that contains all detected 511 keV photon pairs from both isotopes, and a second, tagged (much smaller) dataset that contains only those PET events for which a coincident prompt gamma has also been detected. An image reconstructed from the tagged dataset reflects the distribution of the second positron-gamma radiotracer and serves as a prior for the reconstruction of the primary dataset. Our preliminary simulation study with partially overlapping (18)F/(22)Na and (18)F/(60)Cu radiotracer distributions showed that in these two cases the dual-isotope PET method allowed for separation of the two activity distributions and recovered total activities with relative errors of about 5%.

  18. Sedimentation rates measurements in former channels of the upper Rhône river using Chernobyl 137Cs and 134Cs as tracers.

    PubMed

    Rostan, J C; Juget, J; Brun, A M

    1997-01-30

    Former river channels are aquatic ecosystems with a different geomorphology generated by fluvial dynamics more or less linked to the main channel. They present different ecological successions to become terrestrial ecosystems and are thus supposed to have different sedimentation rates. The aim of this paper is to assess this sedimentation rate using radioactive tracer methodology commonly used in lake studies. Chernobyl impacts, expressed in 137Cs concentration and 137Cs/134Cs ratio, were determined in sediment cores. Sites (21) were sampled in the alluvial plain of the Upper Rhône River from 1989 to 1994. The contamination presented a high spatial heterogeneity. The maximum values encountered by site ranged between 34 and 541 Bq/kg of dry matter. The method generally gave good core profiles. Sedimentation rate ranged between 0.14 and 0.70 cm/year for the former meanders and between 0.14 and 2.86 cm/year for the braided channels. The sediment accumulation rates ranged from 0.03 to 0.25 g/cm2 per year and 0.03 to 2.26 g/cm2 per year, respectively. These values are similar to those found for Lake Geneva. The importance of the former channels in relation to the main channel is enhanced by the higher contamination and radionuclides retention. The sediment accumulation rate is related to the organic carbon content in the sediment. A comparison between two former channels with different productivity showed that the the allogenous driven system presents a high organic sediment accumulation rate with a low organic content in the sediment and inversely, a low organic sediment accumulation rate with a high organic carbon content was found for the autogenous drive system.

  19. Three-phase Bone Scintigraphy Can Predict the Analgesic Efficacy of Ketamine Therapy in CRPS.

    PubMed

    Sorel, Marc; Beatrix, Jacques-Christian; Locko, Blanche; Armessen, Catherine; Domec, Anne-Marie; Lecompte, Otilia; Boucheneb, Sofiane; Harache, Benoit; Robert, Jacques; Lefaucheur, Jean-Pascal

    2018-03-13

    The efficacy of ketamine in relieving complex regional pain syndrome (CRPS) lacks predictive factors. The value of three-phase bone scintigraphy (TPBS) was assessed or this purpose. TPBS was performed in 105 patients with unilateral, focal CRPS of type 1 before 5 days of ketamine infusions. Tracer uptake was measured in the region of interest concerned by CRPS and the contralateral homologous region. For the three scintigraphic phases (vascular, tissular, and bone phases), an asymmetry ratio of fixation was calculated between the affected and the unaffected sides (VPr, TPr, and BPr). Ketamine efficacy was assessed on pain intensity scores. Ketamine-induced pain relief did not correlate with VPr, TPr, and BPr, but with the ratios of these ratios: BPr/TPr (r=0.32, P=0.009), BPr/VPr (r=0.34, P=0.005), and TPr/VPr (r=0.23, P=0.02). The optimum cut-off value for predicting the response to ketamine therapy was >1.125 for BPr/TPr, >1.075 for BPr/VPr, and >0.935 for TPr/VPr. The combination of increased values of BPr/TPr, BPr/VPr, and TPr/VPr was extremely significantly associated with ketamine therapy outcome. The relative hyperfixation of the radioactive tracer in the limb region concerned by CRPS in phases 2 and 3 versus phase 1 of TPBS correlated positively to the analgesic efficacy of ketamine. This study shows for the first time the potential predictive value of TPBS regarding ketamine therapy outcome. In addition, these results suggest that the analgesic action of ketamine is not restricted to "central" mechanisms, but may also involve "peripheral" mechanisms related to tissue inflammation and bone remodeling.

  20. Quantitative single-photon emission computed tomography/computed tomography for technetium pertechnetate thyroid uptake measurement

    PubMed Central

    Lee, Hyunjong; Kim, Ji Hyun; Kang, Yeon-koo; Moon, Jae Hoon; So, Young; Lee, Won Woo

    2016-01-01

    Abstract Objectives: Technetium pertechnetate (99mTcO4) is a radioactive tracer used to assess thyroid function by thyroid uptake system (TUS). However, the TUS often fails to deliver accurate measurements of the percent of thyroid uptake (%thyroid uptake) of 99mTcO4. Here, we investigated the usefulness of quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) after injection of 99mTcO4 in detecting thyroid function abnormalities. Materials and methods: We retrospectively reviewed data from 50 patients (male:female = 15:35; age, 46.2 ± 16.3 years; 17 Graves disease, 13 thyroiditis, and 20 euthyroid). All patients underwent 99mTcO4 quantitative SPECT/CT (185 MBq = 5 mCi), which yielded %thyroid uptake and standardized uptake value (SUV). Twenty-one (10 Graves disease and 11 thyroiditis) of the 50 patients also underwent conventional %thyroid uptake measurements using a TUS. Results: Quantitative SPECT/CT parameters (%thyroid uptake, SUVmean, and SUVmax) were the highest in Graves disease, second highest in euthyroid, and lowest in thyroiditis (P < 0.0001, Kruskal–Wallis test). TUS significantly overestimated the %thyroid uptake compared with SPECT/CT (P < 0.0001, paired t test) because other 99mTcO4 sources in addition to thyroid, such as salivary glands and saliva, contributed to the %thyroid uptake result by TUS, whereas %thyroid uptake, SUVmean and SUVmax from the SPECT/CT were associated with the functional status of thyroid. Conclusions: Quantitative SPECT/CT is more accurate than conventional TUS for measuring 99mTcO4 %thyroid uptake. Quantitative measurements using SPECT/CT may facilitate more accurate assessment of thyroid tracer uptake. PMID:27399139

  1. Measurements of Pu and Ra isotopes in soils and sediments by AMS

    NASA Astrophysics Data System (ADS)

    Tims, S. G.; Hancock, G. J.; Wacker, L.; Fifield, L. K.

    2004-08-01

    Plutonium fallout from atmospheric nuclear weapons testing in the 1950s and 1960s constitutes an artificial tracer suitable for the study of recent soil erosion and sediment accumulation rates. Long-lived Pu isotopes provide an alternative tracer to the more widely used 137Cs (t1/2=30 a), the concentration of which is decaying at a rate that will limit its long-term application to these studies. For 239,240Pu, the sensitivity of AMS is more than an order of magnitude better than that afforded by α-spectroscopy. Furthermore, AMS can provide a simple, direct measure of the 240Pu/239Pu ratio. Sample profiles from two sites along eastern Australia have been determined with both AMS and α-spectroscopy to provide comparative measurements of the sediment accumulation rate in water bodies and of the soil erosion rate. The two methods are in good agreement. The 228Ra/226Ra ratio potentially provides a probe for tracing the dispersion of uranium mining residues into the neighboring environment. Soil depth profiles of the ratio may provide information on the rate at which mining-derived radioactivity is spread by surface waters, and could be used to assess the effectiveness of remediation and rehabilitation technologies. AMS offers several advantages over the more usual α- and γ-spectroscopy techniques in that it can directly and quickly measure both isotopes in a sample of small size and with simple sample preparation. We show that AMS can be used to measure these isotopes of radium at the sensitivity required for environmental samples using RaC2- as the injected beam species.

  2. Double Photon Emission Coincidence Imaging using GAGG-SiPM pixel detectors

    NASA Astrophysics Data System (ADS)

    Shimazoe, K.; Uenomachi, M.; Mizumachi, Y.; Takahashi, H.; Masao, Y.; Shoji, Y.; Kamada, K.; Yoshikawa, A.

    2017-12-01

    Single photon emission computed tomography(SPECT) is a useful medical imaging modality using single photon detection from radioactive tracers, such as 99Tc and 111In, however further development of increasing the contrast in the image is still under investigation. A novel method (Double Photon Emission CT / DPECT) using a coincidence detection of two cascade gamma-rays from 111In is proposed and characterized in this study. 111In, which is well-known and commonly used as a SPECT tracer, emits two cascade photons of 171 keV and 245 keV with a short delay of approximately 85 ns. The coincidence detection of two gamma-rays theoretically determines the position in a single point compared with a line in single photon detection and increases the signal to noise ratio drastically. A fabricated pixel detector for this purpose consists of 8 × 8 array of high-resolution type 1.5 mm thickness Ce:GAGG (3.9% @ 662 keV, 6.63g/cm3, C&A Co. Ce:Gd3Ga2.7Al2.3O12 2.5 × 2.5 × 1.5 mm3) crystals coupled a 3 mm pixel SiPM array (Hamamatsu MPPC S13361-2050NS-08). The signal from each pixel is processed and readout using time over threshold (TOT) based parallel processing circuit to extract the energy and timing information. The coincidence was detected by FPGA with the frequency of 400 MHz. Two pixel detectors coupled to parallel-hole collimators are located at the degree of 90 to determine the position and coincidence events (time window =1 μs) are detected and used for making back-projection image. The basic principle of DPECT is characterized including the detection efficiency and timing resolution.

  3. Comparison of In Vitro Assays in Selecting Radiotracers for In Vivo P-Glycoprotein PET Imaging

    PubMed Central

    Savolainen, Heli; Cantore, Mariangela; van de Steeg, Evita; Colabufo, Nicola A.; Elsinga, Philip H.; Windhorst, Albert D.

    2017-01-01

    Positron emission tomography (PET) imaging of P-glycoprotein (P-gp) in the blood-brain barrier can be important in neurological diseases where P-gp is affected, such as Alzheimer´s disease. Radiotracers used in the imaging studies are present at very small, nanomolar, concentration, whereas in vitro assays where these tracers are characterized, are usually performed at micromolar concentration, causing often discrepant in vivo and in vitro data. We had in vivo rodent PET data of [11C]verapamil, (R)-N-[18F]fluoroethylverapamil, (R)-O-[18F]fluoroethyl-norverapamil, [18F]MC225 and [18F]MC224 and we included also two new molecules [18F]MC198 and [18F]KE64 in this study. To improve the predictive value of in vitro assays, we labeled all the tracers with tritium and performed bidirectional substrate transport assay in MDCKII-MDR1 cells at three different concentrations (0.01, 1 and 50 µM) and also inhibition assay with P-gp inhibitors. As a comparison, we used non-radioactive molecules in transport assay in Caco-2 cells at a concentration of 10 µM and in calcein-AM inhibition assay in MDCKII-MDR1 cells. All the P-gp substrates were transported dose-dependently. At the highest concentration (50 µM), P-gp was saturated in a similar way as after treatment with P-gp inhibitors. Best in vivo correlation was obtained with the bidirectional transport assay at a concentration of 0.01 µM. One micromolar concentration in a transport assay or calcein-AM assay alone is not sufficient for correct in vivo prediction of substrate P-gp PET ligands. PMID:29036881

  4. Simultaneous measurement of glucose transport and utilization in the human brain.

    PubMed

    Shestov, Alexander A; Emir, Uzay E; Kumar, Anjali; Henry, Pierre-Gilles; Seaquist, Elizabeth R; Öz, Gülin

    2011-11-01

    Glucose is the primary fuel for brain function, and determining the kinetics of cerebral glucose transport and utilization is critical for quantifying cerebral energy metabolism. The kinetic parameters of cerebral glucose transport, K(M)(t) and V(max)(t), in humans have so far been obtained by measuring steady-state brain glucose levels by proton ((1)H) NMR as a function of plasma glucose levels and fitting steady-state models to these data. Extraction of the kinetic parameters for cerebral glucose transport necessitated assuming a constant cerebral metabolic rate of glucose (CMR(glc)) obtained from other tracer studies, such as (13)C NMR. Here we present new methodology to simultaneously obtain kinetic parameters for glucose transport and utilization in the human brain by fitting both dynamic and steady-state (1)H NMR data with a reversible, non-steady-state Michaelis-Menten model. Dynamic data were obtained by measuring brain and plasma glucose time courses during glucose infusions to raise and maintain plasma concentration at ∼17 mmol/l for ∼2 h in five healthy volunteers. Steady-state brain vs. plasma glucose concentrations were taken from literature and the steady-state portions of data from the five volunteers. In addition to providing simultaneous measurements of glucose transport and utilization and obviating assumptions for constant CMR(glc), this methodology does not necessitate infusions of expensive or radioactive tracers. Using this new methodology, we found that the maximum transport capacity for glucose through the blood-brain barrier was nearly twofold higher than maximum cerebral glucose utilization. The glucose transport and utilization parameters were consistent with previously published values for human brain.

  5. Two dimensional model study of atmospheric transport using carbon-14 and strontium-90 as inert tracers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinnison, D.E.; Wuebbles, D.J.; Johnston, H.S.

    1992-02-01

    This study tests the transport processes in the LLNL two-dimensional chemical-radiative-transport model using recently reanalyzed carbon-14 and strontium-90 data. These radioactive tracers were produced bythe atmospheric nuclear bomb tests of 1952--58 and 1961--62, and they were measured at a few latitudes up to 35 kilometers over the period 1955--1970. Selected horizontal and vertical eddy diffusion coefficients were varied in the model to test their sensitivity to short and long term transpose of carbon-14. A sharp transition of K[sub zz] and K[sub yy] through the tropopause, as opposed to a slow transition between the same limiting values, shows a distinct improvementmore » in the calculated carbon-14 distributions, a distinct improvement in the calculated seasonal and latitudinal distribution of ozone columns (relative to TOMS observations), and a very large difference in the calculated ozone reduction by a possible fleet of High Speed Civil Transports. Calculated northern hemisphere carbon-14 is more sensitive to variation of K[sub yy] than are global ozone columns. Strontium-90 was used to test the LLNL tropopause height at four different latitudes. Starting with the 1960 background distribution of carbon-14, we calculate the input of carbon-14 as the sum of each nuclear test of the 1961--62 series, using two bomb-cloud rise models. With the Seitz bomb-rise formulation in the LLNL model, we find good agreement between calculated and observedcarbon-14 (with noticeable exceptions at the north polar tropopause and the short-term mid-latitude mid-stratosphere) between 1963 and 1970.« less

  6. Two dimensional model study of atmospheric transport using carbon-14 and strontium-90 as inert tracers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinnison, D.E.; Wuebbles, D.J.; Johnston, H.S.

    1992-02-01

    This study tests the transport processes in the LLNL two-dimensional chemical-radiative-transport model using recently reanalyzed carbon-14 and strontium-90 data. These radioactive tracers were produced bythe atmospheric nuclear bomb tests of 1952--58 and 1961--62, and they were measured at a few latitudes up to 35 kilometers over the period 1955--1970. Selected horizontal and vertical eddy diffusion coefficients were varied in the model to test their sensitivity to short and long term transpose of carbon-14. A sharp transition of K{sub zz} and K{sub yy} through the tropopause, as opposed to a slow transition between the same limiting values, shows a distinct improvementmore » in the calculated carbon-14 distributions, a distinct improvement in the calculated seasonal and latitudinal distribution of ozone columns (relative to TOMS observations), and a very large difference in the calculated ozone reduction by a possible fleet of High Speed Civil Transports. Calculated northern hemisphere carbon-14 is more sensitive to variation of K{sub yy} than are global ozone columns. Strontium-90 was used to test the LLNL tropopause height at four different latitudes. Starting with the 1960 background distribution of carbon-14, we calculate the input of carbon-14 as the sum of each nuclear test of the 1961--62 series, using two bomb-cloud rise models. With the Seitz bomb-rise formulation in the LLNL model, we find good agreement between calculated and observedcarbon-14 (with noticeable exceptions at the north polar tropopause and the short-term mid-latitude mid-stratosphere) between 1963 and 1970.« less

  7. Measuring hepatic functional reserve using low temporal resolution Gd-EOB-DTPA dynamic contrast-enhanced MRI: a preliminary study comparing galactosyl human serum albumin scintigraphy with indocyanine green retention.

    PubMed

    Saito, Kazuhiro; Ledsam, Joseph; Sourbron, Steven; Hashimoto, Tsuyoshi; Araki, Yoichi; Akata, Soichi; Tokuuye, Koichi

    2014-01-01

    To investigate if tracer kinetic modelling of low temporal resolution dynamic contrast-enhanced (DCE) MRI with Gd-EOB-DTPA could replace technetium-99 m galactosyl human serum albumin (GSA) single positron emission computed tomography (SPECT) and indocyanine green (ICG) retention for the measurement of liver functional reserve. Twenty eight patients awaiting liver resection for various cancers were included in this retrospective study that was approved by the institutional review board. The Gd-EOB-DTPA MRI sequence acquired five images: unenhanced, double arterial phase, portal phase, and 4 min after injection. Intracellular contrast uptake rate (UR) and extracellular volume (Ve) were calculated from DCE-MRI, along with the ratio of GSA radioactivity of liver to heart-plus-liver and per cent of cumulative uptake from 15-16 min (LHL15 and LU15, respectively) from GSA-scintigraphy. ICG retention at 15 min, Child-Pugh cirrhosis score (CPS) and postoperative Inuyama fibrosis criteria were also recorded. Statistical analysis was with Spearman rank correlation analysis. Comparing MRI parameters with the reference methods, significant correlations were obtained for UR and LHL15, LU15, ICG15 (all 0.4-0.6, P < 0.05); UR and CPS (-0.64, P < 0.001); Ve and Inuyama (0.44, P < 0.05). Measures of liver function obtained by routine Gd-EOB-DTPA DCE-MRI with tracer kinetic modelling may provide a suitable method for the evaluation of liver functional reserve. • Magnetic resonance imaging (MRI) provides new methods of measuring hepatic functional reserve. • DCE-MRI with Gd-EOB-DTPA offers the possibility of replacing scintigraphy. • The analysis method can be used for preoperative liver function evaluation.

  8. Technical Note: Coupling of chemical processes with the Modular Earth Submodel System (MESSy) submodel TRACER

    NASA Astrophysics Data System (ADS)

    Jöckel, P.; Kerkweg, A.; Buchholz, J.; Tost, H.; Sander, R.; Pozzer, A.

    2007-11-01

    The implementation of processes related to chemistry into Earth System Models and their coupling within such systems requires the consistent description of the chemical species involved. We provide a tool (written in Fortran95) to structure and manage information about constituents, herein after referred to as tracers, namely the Modular Earth Submodel System (MESSy) generic (i.e., infrastructure) submodel TRACER. With TRACER it is possible to define a multitude of tracer sets, depending on the spatio-temporal representation (i.e., the grid structure) of the model. The required information about a specific chemical species is split into the static meta-information about the characteristics of the species, and its (generally in time and space variable) abundance in the corresponding representation. TRACER moreover includes two submodels. One is TRACER_FAMILY, an implementation of the tracer family concept. It distinguishes between two types: type-1 families are usually applied to handle strongly related tracers (e.g., fast equilibrating species) for a specific process (e.g., advection). In contrast to this, type-2 families are applied for tagging techniques, in which specific species are artificially decomposed and associated with additional information, in order to conserve the linear relationship between the family and its members. The second submodel is TRACER_PDEF, which corrects and budgets numerical negative overshoots that arise in many process implementations due to the numerical limitations (limited precision, rounding errors). The submodel therefore guarantees the positive definiteness of the tracers and stabilises the integration scheme. As a by-product, it further provides a global tracer mass diagnostic. Last but not least, we present the submodel PTRAC for the definition of prognostic tracers via a Fortran95 namelist. TRACER with its submodels and PTRAC can readily be applied to a variety of models without further requirements. The code and a documentation is included in the electronic supplement.

  9. 3-D numerical evaluation of density effects on tracer tests.

    PubMed

    Beinhorn, M; Dietrich, P; Kolditz, O

    2005-12-01

    In this paper we present numerical simulations carried out to assess the importance of density-dependent flow on tracer plume development. The scenario considered in the study is characterized by a short-term tracer injection phase into a fully penetrating well and a natural hydraulic gradient. The scenario is thought to be typical for tracer tests conducted in the field. Using a reference case as a starting point, different model parameters were changed in order to determine their importance to density effects. The study is based on a three-dimensional model domain. Results were interpreted using concentration contours and a first moment analysis. Tracer injections of 0.036 kg per meter of saturated aquifer thickness do not cause significant density effects assuming hydraulic gradients of at least 0.1%. Higher tracer input masses, as used for geoelectrical investigations, may lead to buoyancy-induced flow in the early phase of a tracer test which in turn impacts further plume development. This also holds true for shallow aquifers. Results of simulations with different tracer injection rates and durations imply that the tracer input scenario has a negligible effect on density flow. Employing model cases with different realizations of a log conductivity random field, it could be shown that small variations of hydraulic conductivity in the vicinity of the tracer injection well have a major control on the local tracer distribution but do not mask effects of buoyancy-induced flow.

  10. Methods and systems using encapsulated tracers and chemicals for reservoir interrogation and manipulation

    DOEpatents

    Roberts, Jeffery; Aines, Roger D; Duoss, Eric B; Spadaccini, Christopher M

    2014-11-04

    An apparatus, method, and system of reservoir interrogation. A tracer is encapsulating in a receptacle. The receptacle containing the tracer is injected into the reservoir. The tracer is analyzed for reservoir interrogation.

  11. A Lagrangian particle method with remeshing for tracer transport on the sphere

    DOE PAGES

    Bosler, Peter Andrew; Kent, James; Krasny, Robert; ...

    2017-03-30

    A Lagrangian particle method (called LPM) based on the flow map is presented for tracer transport on the sphere. The particles carry tracer values and are located at the centers and vertices of triangular Lagrangian panels. Remeshing is applied to control particle disorder and two schemes are compared, one using direct tracer interpolation and another using inverse flow map interpolation with sampling of the initial tracer density. Test cases include a moving-vortices flow and reversing-deformational flow with both zero and nonzero divergence, as well as smooth and discontinuous tracers. We examine the accuracy of the computed tracer density and tracermore » integral, and preservation of nonlinear correlation in a pair of tracers. Here, we compare results obtained using LPM and the Lin–Rood finite-volume scheme. An adaptive particle/panel refinement scheme is demonstrated.« less

  12. A Lagrangian particle method with remeshing for tracer transport on the sphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosler, Peter Andrew; Kent, James; Krasny, Robert

    A Lagrangian particle method (called LPM) based on the flow map is presented for tracer transport on the sphere. The particles carry tracer values and are located at the centers and vertices of triangular Lagrangian panels. Remeshing is applied to control particle disorder and two schemes are compared, one using direct tracer interpolation and another using inverse flow map interpolation with sampling of the initial tracer density. Test cases include a moving-vortices flow and reversing-deformational flow with both zero and nonzero divergence, as well as smooth and discontinuous tracers. We examine the accuracy of the computed tracer density and tracermore » integral, and preservation of nonlinear correlation in a pair of tracers. Here, we compare results obtained using LPM and the Lin–Rood finite-volume scheme. An adaptive particle/panel refinement scheme is demonstrated.« less

  13. Theoretical foundation for measuring the groundwater age distribution.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gardner, William Payton; Arnold, Bill Walter

    2014-01-01

    In this study, we use PFLOTRAN, a highly scalable, parallel, flow and reactive transport code to simulate the concentrations of 3H, 3He, CFC-11, CFC-12, CFC-113, SF6, 39Ar, 81Kr, 4He and themean groundwater age in heterogeneous fields on grids with an excess of 10 million nodes. We utilize this computational platform to simulate the concentration of multiple tracers in high-resolution, heterogeneous 2-D and 3-D domains, and calculate tracer-derived ages. Tracer-derived ages show systematic biases toward younger ages when the groundwater age distribution contains water older than the maximum tracer age. The deviation of the tracer-derived age distribution from the true groundwatermore » age distribution increases with increasing heterogeneity of the system. However, the effect of heterogeneity is diminished as the mean travel time gets closer the tracer age limit. Age distributions in 3-D domains differ significantly from 2-D domains. 3D simulations show decreased mean age, and less variance in age distribution for identical heterogeneity statistics. High-performance computing allows for investigation of tracer and groundwater age systematics in high-resolution domains, providing a platform for understanding and utilizing environmental tracer and groundwater age information in heterogeneous 3-D systems. Groundwater environmental tracers can provide important constraints for the calibration of groundwater flow models. Direct simulation of environmental tracer concentrations in models has the additional advantage of avoiding assumptions associated with using calculated groundwater age values. This study quantifies model uncertainty reduction resulting from the addition of environmental tracer concentration data. The analysis uses a synthetic heterogeneous aquifer and the calibration of a flow and transport model using the pilot point method. Results indicate a significant reduction in the uncertainty in permeability with the addition of environmental tracer data, relative to the use of hydraulic measurements alone. Anthropogenic tracers and their decay products, such as CFC11, 3H, and 3He, provide significant constraint oninput permeability values in the model. Tracer data for 39Ar provide even more complete information on the heterogeneity of permeability and variability in the flow system than the anthropogenic tracers, leading to greater parameter uncertainty reduction.« less

  14. Assessing the Accuracy of the Tracer Dilution Method with Atmospheric Dispersion Modeling

    NASA Astrophysics Data System (ADS)

    Taylor, D.; Delkash, M.; Chow, F. K.; Imhoff, P. T.

    2015-12-01

    Landfill methane emissions are difficult to estimate due to limited observations and data uncertainty. The mobile tracer dilution method is a widely used and cost-effective approach for predicting landfill methane emissions. The method uses a tracer gas released on the surface of the landfill and measures the concentrations of both methane and the tracer gas downwind. Mobile measurements are conducted with a gas analyzer mounted on a vehicle to capture transects of both gas plumes. The idea behind the method is that if the measurements are performed far enough downwind, the methane plume from the large area source of the landfill and the tracer plume from a small number of point sources will be sufficiently well-mixed to behave similarly, and the ratio between the concentrations will be a good estimate of the ratio between the two emissions rates. The mobile tracer dilution method is sensitive to different factors of the setup such as placement of the tracer release locations and distance from the landfill to the downwind measurements, which have not been thoroughly examined. In this study, numerical modeling is used as an alternative to field measurements to study the sensitivity of the tracer dilution method and provide estimates of measurement accuracy. Using topography and wind conditions for an actual landfill, a landfill emissions rate is prescribed in the model and compared against the emissions rate predicted by application of the tracer dilution method. Two different methane emissions scenarios are simulated: homogeneous emissions over the entire surface of the landfill, and heterogeneous emissions with a hot spot containing 80% of the total emissions where the daily cover area is located. Numerical modeling of the tracer dilution method is a useful tool for evaluating the method without having the expense and labor commitment of multiple field campaigns. Factors tested include number of tracers, distance between tracers, distance from landfill to transect path, and location of tracers with respect to the hot spot. Results show that location of the tracers relative to the hot spot of highest landfill emissions makes the largest difference in accuracy of the tracer dilution method.

  15. Heat and solute tracers: how do they compare in heterogeneous aquifers?

    PubMed

    Irvine, Dylan J; Simmons, Craig T; Werner, Adrian D; Graf, Thomas

    2015-04-01

    A comparison of groundwater velocity in heterogeneous aquifers estimated from hydraulic methods, heat and solute tracers was made using numerical simulations. Aquifer heterogeneity was described by geostatistical properties of the Borden, Cape Cod, North Bay, and MADE aquifers. Both heat and solute tracers displayed little systematic under- or over-estimation in velocity relative to a hydraulic control. The worst cases were under-estimates of 6.63% for solute and 2.13% for the heat tracer. Both under- and over-estimation of velocity from the heat tracer relative to the solute tracer occurred. Differences between the estimates from the tracer methods increased as the mean velocity decreased, owing to differences in rates of molecular diffusion and thermal conduction. The variance in estimated velocity using all methods increased as the variance in log-hydraulic conductivity (K) and correlation length scales increased. The variance in velocity for each scenario was remarkably small when compared to σ2 ln(K) for all methods tested. The largest variability identified was for the solute tracer where 95% of velocity estimates ranged by a factor of 19 in simulations where 95% of the K values varied by almost four orders of magnitude. For the same K-fields, this range was a factor of 11 for the heat tracer. The variance in estimated velocity was always lowest when using heat as a tracer. The study results suggest that a solute tracer will provide more understanding about the variance in velocity caused by aquifer heterogeneity and a heat tracer provides a better approximation of the mean velocity. © 2013, National Ground Water Association.

  16. On the linearity of tracer bias around voids

    NASA Astrophysics Data System (ADS)

    Pollina, Giorgia; Hamaus, Nico; Dolag, Klaus; Weller, Jochen; Baldi, Marco; Moscardini, Lauro

    2017-07-01

    The large-scale structure of the Universe can be observed only via luminous tracers of the dark matter. However, the clustering statistics of tracers are biased and depend on various properties, such as their host-halo mass and assembly history. On very large scales, this tracer bias results in a constant offset in the clustering amplitude, known as linear bias. Towards smaller non-linear scales, this is no longer the case and tracer bias becomes a complicated function of scale and time. We focus on tracer bias centred on cosmic voids, I.e. depressions of the density field that spatially dominate the Universe. We consider three types of tracers: galaxies, galaxy clusters and active galactic nuclei, extracted from the hydrodynamical simulation Magneticum Pathfinder. In contrast to common clustering statistics that focus on auto-correlations of tracers, we find that void-tracer cross-correlations are successfully described by a linear bias relation. The tracer-density profile of voids can thus be related to their matter-density profile by a single number. We show that it coincides with the linear tracer bias extracted from the large-scale auto-correlation function and expectations from theory, if sufficiently large voids are considered. For smaller voids we observe a shift towards higher values. This has important consequences on cosmological parameter inference, as the problem of unknown tracer bias is alleviated up to a constant number. The smallest scales in existing data sets become accessible to simpler models, providing numerous modes of the density field that have been disregarded so far, but may help to further reduce statistical errors in constraining cosmology.

  17. Can nanotechnology help advance glaciological research?

    NASA Astrophysics Data System (ADS)

    Dahlke, H. E.; McNew, C.; Wang, C.; McLaughlin, S.; Kocis, T. N.

    2017-12-01

    In a rapidly changing cryosphere, identifying sources, pathways, and residence times of snow and glacier meltwater is critical to developing improved understanding of watershed-stream connections and hydrological/glaciological melt models. Traditionally, glaciologists have used a variety of tracers, including chloride, microparticles, and dyes, to identify the structure and morphology of subglacial drainage systems. However, minimum detection limits, tracer expense, and the ability of watersheds to retain a memory of past tracer inputs have restricted both the scale of tracer application and the repeated or simultaneous use of most known tracers, thus limiting our ability to study complex glacial systems. These shortcomings in hydrologic tracers can be overcome by utilizing a tracer that allows for the unique identification between spatial and temporal inputs while maintaining identical transport characteristics. Here, we present the use of DNA-labeled nanoparticles, developed for nano-medicine and drug delivery, as environmental tracers. The DNA-labeled particle tracers consist of short DNA strands encapsulated within biodegradable polymer microspheres, which allow for repeatable production of numerous uniquely labelled tracers of pre-determined size and physical transport properties. Each batch of tracers are independently quantifiable; even a single DNA molecule can be detected with cost-effective quantitative polymerase chain reaction (qPCR). We have tested our tracer technology in complex systems such as valley glaciers in Sweden and Alaska and in both laboratory and field studies of channel flow, overland flow, and flow in porous media; these proof-of-concept studies indicate that nanotechnology allows for powerful characterization, description, and, ultimately, prediction of flow pathways in glacial systems and the environment.

  18. Complex functionality with minimal computation: Promise and pitfalls of reduced-tracer ocean biogeochemistry models

    NASA Astrophysics Data System (ADS)

    Galbraith, Eric D.; Dunne, John P.; Gnanadesikan, Anand; Slater, Richard D.; Sarmiento, Jorge L.; Dufour, Carolina O.; de Souza, Gregory F.; Bianchi, Daniele; Claret, Mariona; Rodgers, Keith B.; Marvasti, Seyedehsafoura Sedigh

    2015-12-01

    Earth System Models increasingly include ocean biogeochemistry models in order to predict changes in ocean carbon storage, hypoxia, and biological productivity under climate change. However, state-of-the-art ocean biogeochemical models include many advected tracers, that significantly increase the computational resources required, forcing a trade-off with spatial resolution. Here, we compare a state-of-the art model with 30 prognostic tracers (TOPAZ) with two reduced-tracer models, one with 6 tracers (BLING), and the other with 3 tracers (miniBLING). The reduced-tracer models employ parameterized, implicit biological functions, which nonetheless capture many of the most important processes resolved by TOPAZ. All three are embedded in the same coupled climate model. Despite the large difference in tracer number, the absence of tracers for living organic matter is shown to have a minimal impact on the transport of nutrient elements, and the three models produce similar mean annual preindustrial distributions of macronutrients, oxygen, and carbon. Significant differences do exist among the models, in particular the seasonal cycle of biomass and export production, but it does not appear that these are necessary consequences of the reduced tracer number. With increasing CO2, changes in dissolved oxygen and anthropogenic carbon uptake are very similar across the different models. Thus, while the reduced-tracer models do not explicitly resolve the diversity and internal dynamics of marine ecosystems, we demonstrate that such models are applicable to a broad suite of major biogeochemical concerns, including anthropogenic change. These results are very promising for the further development and application of reduced-tracer biogeochemical models that incorporate "sub-ecosystem-scale" parameterizations.

  19. Experiments to Evaluate and Implement Passive Tracer Gas Methods to Measure Ventilation Rates in Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lunden, Melissa; Faulkner, David; Heredia, Elizabeth

    2012-10-01

    This report documents experiments performed in three homes to assess the methodology used to determine air exchange rates using passive tracer techniques. The experiments used four different tracer gases emitted simultaneously but implemented with different spatial coverage in the home. Two different tracer gas sampling methods were used. The results characterize the factors of the execution and analysis of the passive tracer technique that affect the uncertainty in the calculated air exchange rates. These factors include uncertainties in tracer gas emission rates, differences in measured concentrations for different tracer gases, temporal and spatial variability of the concentrations, the comparison betweenmore » different gas sampling methods, and the effect of different ventilation conditions.« less

  20. Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2005)

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...

  1. Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2003)

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...

  2. Dynamic dual-tracer PET reconstruction.

    PubMed

    Gao, Fei; Liu, Huafeng; Jian, Yiqiang; Shi, Pengcheng

    2009-01-01

    Although of important medical implications, simultaneous dual-tracer positron emission tomography reconstruction remains a challenging problem, primarily because the photon measurements from dual tracers are overlapped. In this paper, we propose a simultaneous dynamic dual-tracer reconstruction of tissue activity maps based on guidance from tracer kinetics. The dual-tracer reconstruction problem is formulated in a state-space representation, where parallel compartment models serve as continuous-time system equation describing the tracer kinetic processes of dual tracers, and the imaging data is expressed as discrete sampling of the system states in measurement equation. The image reconstruction problem has therefore become a state estimation problem in a continuous-discrete hybrid paradigm, and H infinity filtering is adopted as the estimation strategy. As H infinity filtering makes no assumptions on the system and measurement statistics, robust reconstruction results can be obtained for the dual-tracer PET imaging system where the statistical properties of measurement data and system uncertainty are not available a priori, even when there are disturbances in the kinetic parameters. Experimental results on digital phantoms, Monte Carlo simulations and physical phantoms have demonstrated the superior performance.

  3. Adenosine receptor agonist NECA increases cerebral extravasation of fluorescein and low molecular weight dextran independent of blood-brain barrier modulation

    PubMed Central

    Cheng, Chih-Chung; Yang, Ya Lan; Liao, Kate Hsiurong; Lai, Ted Weita

    2016-01-01

    Conventional methods for therapeutic blood-brain barrier (BBB) disruption facilitate drug delivery but are cumbersome to perform. A previous study demonstrated that adenosine receptor (AR) stimulation by 5′-N-ethylcarboxamide adenosine (NECA) increased the extravasation of intravascular tracers into the brain and proposed that AR agonism may be an effective method for therapeutic BBB disruption. We attempted to confirm the extravasation of tracers into the brain and also investigated tracer extravasation into peripheral organs and tracer retention in the blood. We found that NECA not only increased the extravasation of intravascular fluorescein and low molecular weight dextran into the brain of mice but also increased the concentrations of these tracers in the blood. In fact, the brain:blood ratio-normalized BBB permeability for either tracer is actually decreased by NECA administration. Elevated blood urea nitrogen levels in mice following NECA treatment suggested that renal function impairment was a probable cause of tracer retention. Therefore, NECA has almost no effect on the extravasation of intravascular Evans blue dye (EBD), an albumin-binding tracer with little renal clearance. Rather than inducing BBB disruption, our study demonstrated that NECA increased tracer extravasation into the brain by increasing the concentration gradient of the tracer across the BBB. PMID:27025761

  4. Wirelessly powered micro-tracer enabled by miniaturized antenna and microfluidic channel

    NASA Astrophysics Data System (ADS)

    Duan, G.; Zhao, X.; Seren, H. R.; Chen, C.; Zhang, X.

    2015-12-01

    A miniaturized antenna, 380μm by 380μm in size, was fabricated and integrated with a commercialized passive RFID chip to form a micro-tracer, whose size was 2mm by 1mm in total. The micro-tracer was wirelessly powered and interrogated by a single layer spiral reader antenna through near field coupling. To maximize the working distance, the resonant frequency of micro-tracer and reader antenna were matched at 840MHz. Due to the ultra small size of the tracer antenna, power transfer efficiency decreased dramatically as the distance between tracer antenna and reader antenna increased, thus the working distance of the microtracer was limited within 1mm. To achieve massive operation of the micro-tracer, a microfluidic platform was fabricated with in channel focusing and separation. Acrylic sheets were laser cut to define the channel and cover structure, then bonded together layer by layer with a glass substrate, on which reader antenna was integrated. Pump oil was used as the fluidic media carrying the micro-tracer flowing inside the microfluidic channel. The wireless power transfer and real-time communication was demonstrated with the micro-tracer flowing above the reader antenna, as the ID of the micro-tracer was retrieved and displayed on a computer screen.

  5. Adenosine receptor agonist NECA increases cerebral extravasation of fluorescein and low molecular weight dextran independent of blood-brain barrier modulation.

    PubMed

    Cheng, Chih-Chung; Yang, Ya Lan; Liao, Kate Hsiurong; Lai, Ted Weita

    2016-03-30

    Conventional methods for therapeutic blood-brain barrier (BBB) disruption facilitate drug delivery but are cumbersome to perform. A previous study demonstrated that adenosine receptor (AR) stimulation by 5'-N-ethylcarboxamide adenosine (NECA) increased the extravasation of intravascular tracers into the brain and proposed that AR agonism may be an effective method for therapeutic BBB disruption. We attempted to confirm the extravasation of tracers into the brain and also investigated tracer extravasation into peripheral organs and tracer retention in the blood. We found that NECA not only increased the extravasation of intravascular fluorescein and low molecular weight dextran into the brain of mice but also increased the concentrations of these tracers in the blood. In fact, the brain:blood ratio-normalized BBB permeability for either tracer is actually decreased by NECA administration. Elevated blood urea nitrogen levels in mice following NECA treatment suggested that renal function impairment was a probable cause of tracer retention. Therefore, NECA has almost no effect on the extravasation of intravascular Evans blue dye (EBD), an albumin-binding tracer with little renal clearance. Rather than inducing BBB disruption, our study demonstrated that NECA increased tracer extravasation into the brain by increasing the concentration gradient of the tracer across the BBB.

  6. EFFICIENT HYDROLOGICAL TRACER-TEST DESIGN (EHTD ...

    EPA Pesticide Factsheets

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed that combines basic measured field parameters (e.g., discharge, distance, cross-sectional area) in functional relationships that describe solute-transport processes related to flow velocity and time of travel. The new method applies these initial estimates for time of travel and velocity to a hypothetical continuously stirred tank reactor as an analog for the hydrologic flow system to develop initial estimates for tracer concentration and axial dispersion, based on a preset average tracer concentration. Root determination of the one-dimensional advection-dispersion equation (ADE) using the preset average tracer concentration then provides a theoretical basis for an estimate of necessary tracer mass.Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to

  7. One year of tracer dispersion measurements over Washington, D.C.

    NASA Astrophysics Data System (ADS)

    Draxler, Roland R.

    Two perfluorocarbon tracers were released for 6 h from several locations about 20 km outside of Washington, D.C. at 36-h intervals for over 1 year. Continuous air samples were collected at 8-h intervals at one urban and two suburban sites, and at monthly intervals at 93 sites all over the region. Over 50 % of the 8-h samples showed no tracer concentration. However, about 20% of the samples had significant amounts of tracer, so that about 600 values under a variety of meteorological conditions are available for analysis. Although the Potomac River is only 100 m below the surrounding terrain, the tracer releases from within the river valley indicated that the tracer flow was channeled along the river valley. For tracer released away from the river valley, the tracer tended to pass aloft and not mix down into the river valley. Sequential concentration measurements frequently showed high values for extended periods after the tracer release terminated, decreasing exponentially with a half life of about 3 h. This suggests that the finite tracer plume may have a rather long upwind trailing edge toward the release point. The average rate of change in the vertical dispersion during summer and winter was found to be proportional to the 0.6 power of distance.

  8. Deuterium used as artificial tracer in column studies under saturated water flow conditions

    NASA Astrophysics Data System (ADS)

    Koeniger, P.; Geiges, M.; Leibundgut, Ch.

    2003-04-01

    In contrast to numerous investigations using deuterium as an environmental tracer, hydrological investigations with deuterium-labelled water are rather rare. Currently applications in groundwater studies are restricted due to increasing costs of spiking large water quantities but an application as intelligent tracer might be of advantage especially in combination with other tracers and under distinct environmental conditions. Therefore deuterium was applied as artificial tracer in column experiments that are well proved as a tool to characterise tracer behaviour in recent studies. Deuterium was tested in comparison to the more familiar conservative tracer fluorescein. Varying experimental conditions, e.g. column length (0.5, 1.0, 1.5 m), initial tracer concentration (0.01, 0.02, 0.2 mg) and flow velocity (1.5 to 6.0 m/d) were used to investigate tracer behaviour under saturated water flow conditions. Deuterium was analysed using an H/Device with chrome reduction connected to an isotope ratio mass spectrometer and expressed in relative concentrations [per mill V-SMOW]. Theoretical tracer breakthrough curves were calculated using a one dimensional dispersion model. The results indicate higher mean transport velocities and smaller dispersion for deuterium in all experiments. Due to different molecule properties that also determine the interaction of soil substrate and tracer, deuterium indicates a more conservative transport behaviour. Deuterium is non-toxic, completely soluble, chemically and biologically stable and not subject to light-influenced decay. Furthermore, it shows promise for investigations of water flow in the unsaturated zone, and of interactions of water in soil-plant-atmosphere systems. A further discussion of problems, together with possibilities for applying deuterium as an artificial tracer, will be presented.

  9. Application of Tracer-Injection Techniques to Demonstrate Surface-Water and Ground-Water Interactions Between an Alpine Stream and the North Star Mine, Upper Animas River Watershed, Southwestern Colorado

    USGS Publications Warehouse

    Wright, Winfield G.; Moore, Bryan

    2003-01-01

    Tracer-injection studies were done in Belcher Gulch in the upper Animas River watershed, southwestern Colorado, to determine whether the alpine stream infiltrates into underground mine workings of the North Star Mine and other nearby mines in the area. The tracer-injection studies were designed to determine if and where along Belcher Gulch the stream infiltrates into the mine. Four separate tracer-injec-tion tests were done using lithium bromide (LiBr), optical brightener dye, and sodium chloride (NaCl) as tracer solu-tions. Two of the tracers (LiBr and dye) were injected con-tinuously for 24 hours, one of the NaCl tracers was injected continuously for 12 hours, and one of the NaCl tracers was injected over a period of 1 hour. Concentration increases of tracer constituents were detected in water discharging from the North Star Mine, substantiating a surface-water and ground-water connection between Belcher Gulch and the North Star Mine. Different timing and magnitude of tracer breakthroughs indicated multiple flow paths with different residence times from the stream to the mine. The Pittsburgh and Sultan Mines were thought to physically connect to the North Star Mine, but tracer breakthroughs were inconclusive in water from these mines. From the tracer-injection tests and synoptic measure-ments of streamflow discharge, a conceptual model was devel-oped for surface-water and ground-water interactions between Belcher Gulch and the North Star Mine. This information, combined with previous surface geophysical surveys indicat-ing the presence of subsurface voids, may assist with decision-making process for preventing infiltration and for the remedia-tion of mine drainage from these mines.

  10. Simultaneous Analyses and Applications of Multiple Fluorobenzoate and Halide Tracers in Hydrologic Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Q; Moran, J E

    2004-01-22

    An analytical method that employs ion chromatography has been developed to more fully exploit the use of fluorobenzoic acids (FBAs) and halides as hydrologic tracers. In a single run, this reliable, sensitive, and robust method can simultaneously separate and quantify halides (fluoride, chloride, bromide, and iodide) and up to seven FBAs from other common groundwater constituents (e.g., nitrate and sulfate). The usefulness of this ion chromatographic (IC) analytical method is demonstrated in both field and laboratory tracer experiments. Field experiments in unsaturated tuff featuring fractures or a fault show that this efficient and cost-effective method helps achieve the objectives ofmore » tracer studies that use multiple FBAs and/or diffusivity tracers (simultaneous use of one or more FBA and halide). The field study examines the hydrologic response of fractures and the matrix to different flow rates and the contribution of matrix diffusion in chemical transport. Laboratory tracer experiments with eight geologic media from across the United States--mostly from Department of Energy facilities where groundwater contamination is prevalent and where subsurface characterization employing tracers has been ongoing or is in need--reveal several insights about tracer transport behavior: (1) Bromide and FBAs are not always transported conservatively. (2) The delayed transport of these anionic tracers is likely related to geologic media characteristics, such as organic matter, pH, iron oxide content, and clay mineralogy. (3) Any use of iodine as a hydrologic tracer should take into account the different sorption behaviors of iodide and iodate and the possible conversion of iodine's initial chemical form. (4) The transport behavior of potential FBA and halide tracers under relevant geochemical conditions should be evaluated before beginning ambitious, large-scale field tracer experiments.« less

  11. Translation of New Molecular Imaging Approaches to the Clinical Setting: Bridging the Gap to Implementation.

    PubMed

    van Es, Suzanne C; Venema, Clasina M; Glaudemans, Andor W J M; Lub-de Hooge, Marjolijn N; Elias, Sjoerd G; Boellaard, Ronald; Hospers, Geke A P; Schröder, Carolina P; de Vries, Elisabeth G E

    2016-02-01

    Molecular imaging with PET is a rapidly emerging technique. In breast cancer patients, more than 45 different PET tracers have been or are presently being tested. With a good rationale, after development of the tracer and proven feasibility, it is of interest to evaluate whether there is a potential meaningful role for the tracer in the clinical setting-such as in staging, in the (early) prediction of a treatment response, or in supporting drug choices. So far, only (18)F-FDG PET has been incorporated into breast cancer guidelines. For proof of the clinical relevance of tracers, especially for analysis in a multicenter setting, standardization of the technology and access to the novel PET tracer are required. However, resources for PET implementation research are limited. Therefore, next to randomized studies, novel approaches are required for proving the clinical value of PET tracers with the smallest possible number of patients. The aim of this review is to describe the process of the development of PET tracers and the level of evidence needed for the use of these tracers in breast cancer. Several breast cancer trials have been performed with the PET tracers (18)F-FDG, 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT), and (18)F-fluoroestradiol ((18)F-FES). We studied them to learn lessons for the implementation of novel tracers. After defining the gap between a good rationale for a tracer and implementation in the clinical setting, we propose solutions to fill the gap to try to bring more PET tracers to daily clinical practice. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  12. Complex functionality with minimal computation. Promise and pitfalls of reduced-tracer ocean biogeochemistry models

    DOE PAGES

    Galbraith, Eric D.; Dunne, John P.; Gnanadesikan, Anand; ...

    2015-12-21

    Earth System Models increasingly include ocean biogeochemistry models in order to predict changes in ocean carbon storage, hypoxia, and biological productivity under climate change. However, state-of-the-art ocean biogeochemical models include many advected tracers, that significantly increase the computational resources required, forcing a trade-off with spatial resolution. Here, we compare a state-of the art model with 30 prognostic tracers (TOPAZ) with two reduced-tracer models, one with 6 tracers (BLING), and the other with 3 tracers (miniBLING). The reduced-tracer models employ parameterized, implicit biological functions, which nonetheless capture many of the most important processes resolved by TOPAZ. All three are embedded inmore » the same coupled climate model. Despite the large difference in tracer number, the absence of tracers for living organic matter is shown to have a minimal impact on the transport of nutrient elements, and the three models produce similar mean annual preindustrial distributions of macronutrients, oxygen, and carbon. Significant differences do exist among the models, in particular the seasonal cycle of biomass and export production, but it does not appear that these are necessary consequences of the reduced tracer number. With increasing CO2, changes in dissolved oxygen and anthropogenic carbon uptake are very similar across the different models. Thus, while the reduced-tracer models do not explicitly resolve the diversity and internal dynamics of marine ecosystems, we demonstrate that such models are applicable to a broad suite of major biogeochemical concerns, including anthropogenic change. Lastly, these results are very promising for the further development and application of reduced-tracer biogeochemical models that incorporate ‘‘sub-ecosystem-scale’’ parameterizations.« less

  13. A line source tracer test - a better method for assessing high groundwater velocity

    NASA Astrophysics Data System (ADS)

    Magal, E.; Weisbrod, N.; Yakirevich, A.; Kurtzman, D.; Yechieli, Y.

    2009-12-01

    A line source injection is suggested as an effective method for assessing groundwater velocities and flow directions in subsurface characterized by high water fluxes. Modifying the common techniques of injecting a tracer into a well was necessary after frequently-used methods of natural and forced gradient tracer tests ended with no reliable information on the local groundwater flow. In a field experiment, tracers were injected into 8-m long line injection system constructed below the water table almost perpendicular to the assumed flow direction. The injection system was divided to four separate segments (each 2 m long) enabling the injection of four different tracers along the line source. An array of five boreholes located in an area of 10x10 m downstream was used for monitoring the tracers' transport. Two dye tracers (Uranine and Na Naphthionate) were injected in a long pulse of several hours into two of the injection pipe segments and two tracers (Rhenium oxide and Gd-DTPA) were instantaneously injected to the other two segments. The tracers were detected 0.7 to 2.3 hours after injection in four of the five observation wells, located 2.3 to 10 m from the injection system, respectively. Groundwater velocities were calculated directly from the tracers' arrival times and by fitting the observed breakthrough curves to simulations with one and two dimensions analytical solutions for conservative tracer transport. The groundwater velocity was determined to be ~100 m/d. The longitudinal dispersivity value, generated from fitting the tracer breakthrough curves, was in a range of 0.2-3m. The groundwater flow direction was derived based on the arrival of the tracers and was found to be consistent with the apparent direction of the hydraulic gradient. The hydraulic conductivity derived from the groundwater velocity was ~1200 m/d, which is in the upper range of gravel sediment.

  14. EVALUATION OF LEAKAGE FROM FUME HOODS USING TRACER GAS, TRACER NANOPARTICLES AND NANOPOWDER HANDLING TEST METHODOLOGIES

    PubMed Central

    Dunn, Kevin H.; Tsai, Candace Su-Jung; Woskie, Susan R.; Bennett, James S.; Garcia, Alberto; Ellenbecker, Michael J.

    2015-01-01

    The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 feet/minute) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust air flows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity. PMID:25175285

  15. Evaluation of leakage from fume hoods using tracer gas, tracer nanoparticles and nanopowder handling test methodologies.

    PubMed

    Dunn, Kevin H; Tsai, Candace Su-Jung; Woskie, Susan R; Bennett, James S; Garcia, Alberto; Ellenbecker, Michael J

    2014-01-01

    The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 ft/min) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust airflows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity.

  16. Impact of community tracer teams on treatment outcomes among tuberculosis patients in South Africa.

    PubMed

    Bronner, Liza E; Podewils, Laura J; Peters, Annatjie; Somnath, Pushpakanthi; Nshuti, Lorna; van der Walt, Martie; Mametja, Lerole David

    2012-08-07

    Tuberculosis (TB) indicators in South Africa currently remain well below global targets. In 2008, the National Tuberculosis Program (NTP) implemented a community mobilization program in all nine provinces to trace TB patients that had missed a treatment or clinic visit. Implementation sites were selected by TB program managers and teams liaised with health facilities to identify patients for tracing activities. The objective of this analysis was to assess the impact of the TB Tracer Project on treatment outcomes among TB patients. The study population included all smear positive TB patients registered in the Electronic TB Registry from Quarter 1 2007-Quarter 1 2009 in South Africa. Subdistricts were used as the unit of analysis, with each designated as either tracer (standard TB program plus tracer project) or non-tracer (standard TB program only). Mixed linear regression models were utilized to calculate the percent quarterly change in treatment outcomes and to compare changes in treatment outcomes from Quarter 1 2007 to Quarter 1 2009 between tracer and non-tracer subdistricts. For all provinces combined, the percent quarterly change decreased significantly for default treatment outcomes among tracer subdistricts (-0.031%; p < 0.001) and increased significantly for successful treatment outcomes among tracer subdistricts (0.003%; p = 0.03). A significant decrease in the proportion of patient default was observed for all provinces combined over the time period comparing tracer and non-tracer subdistricts (p = 0.02). Examination in stratified models revealed the results were not consistent across all provinces; significant differences were observed between tracer and non-tracer subdistricts over time in five of nine provinces for treatment default. Community mobilization of teams to trace TB patients that missed a clinic appointment or treatment dose may be an effective strategy to mitigate default rates and improve treatment outcomes. Additional information is necessary to identify best practices and elucidate discrepancies across provinces; these findings will help guide the NTP in optimizing the adoption of tracing activities for TB control.

  17. Coarsening of physics for biogeochemical model in NEMO

    NASA Astrophysics Data System (ADS)

    Bricaud, Clement; Le Sommer, Julien; Madec, Gurvan; Deshayes, Julie; Chanut, Jerome; Perruche, Coralie

    2017-04-01

    Ocean mesoscale and submesoscale turbulence contribute to ocean tracer transport and to shaping ocean biogeochemical tracers distribution. Representing adequately tracer transport in ocean models therefore requires to increase model resolution so that the impact of ocean turbulence is adequately accounted for. But due to supercomputers power and storage limitations, global biogeochemical models are not yet run routinely at eddying resolution. Still, because the "effective resolution" of eddying ocean models is much coarser than the physical model grid resolution, tracer transport can be reconstructed to a large extent by computing tracer transport and diffusion with a model grid resolution close to the effective resolution of the physical model. This observation has motivated the implementation of a new capability in NEMO ocean model (http://www.nemo-ocean.eu/) that allows to run the physical model and the tracer transport model at different grid resolutions. In a first time, we present results obtained with this new capability applied to a synthetic age tracer in a global eddying model configuration. In this model configuration, ocean dynamic is computed at ¼° resolution but tracer transport is computed at 3/4° resolution. The solution obtained is compared to 2 reference setup ,one at ¼° resolution for both physics and passive tracer models and one at 3/4° resolution for both physics and passive tracer model. We discuss possible options for defining the vertical diffusivity coefficient for the tracer transport model based on information from the high resolution grid. We describe the impact of this choice on the distribution and one the penetration of the age tracer. In a second time we present results obtained by coupling the physics with the biogeochemical model PISCES. We look at the impact of this methodology on some tracers distribution and dynamic. The method described here can found applications in ocean forecasting, such as the Copernicus Marine service operated by Mercator-Ocean, and in Earth System Models for climate applications.

  18. Fractured-rock hydrogeophysics with electrically conductive and neutrally buoyant tracers

    NASA Astrophysics Data System (ADS)

    Shakas, A.; Linde, N.; Baron, L.; Le Borgne, T.; Bour, O.; Lavenant, N.; Gerard, M. F.

    2016-12-01

    Artificial tracer tests help to characterize and understand the dynamics of groundwater systems. This remains a challenging task, especially when dealing with highly heterogeneous formations in which flow can be very localized and the interpretation of tracer breakthrough curves may be ambiguous. As a complement to tracer tests, ground-penetrating radar (GPR) and electrical resistivity tomography can map the space-time migration of electrically conductive tracers. In hydrogeophysics, the most common tracer is dissolved table salt in water. However, conventional salt tracers lead to density effects that are often ignored. Even less than 1% density variations can have a dramatic effect on transport behavior and affect tracer tests in complex ways. Such effects have been demonstrated in our previous experiments that used single-hole GPR to monitor saline push-pull tests in fractured granite. It is possible to model density effects, but this leads to computational complexity and field dynamics that are not necessarily representative of the natural responses of the system. To minimize density effects, we performed a new set of push-pull tests using a neutrally buoyant and electrically conductive tracer at the same test site located close to Ploemeur, France. This novel tracer consists of a mixture of salt (NaCl), water and pure ethanol. Ethanol has a density of 789 g/L at 20° C and is used to counter-act the salt-induced density increase. Our GPR time-lapse images and tracer breakthrough data indicate a largely reversible transport process that confirms the neutral buoyancy of the tracer. Ethanol is biodegradable and does not pose significant environmental issues. Furthermore, calibration of the neutral-buoyant mixture is straightforward to perform in the field using Archimedes principle. Based on these results, we argue that neutrally buoyant ethanol-salt-water mixtures are ideal for a wide variety of hydrogeophysical tracer tests in porous or fractured media.

  19. Comparison of thermal, salt and dye tracing to estimate shallow flow velocities: Novel triple-tracer approach

    NASA Astrophysics Data System (ADS)

    Abrantes, João R. C. B.; Moruzzi, Rodrigo B.; Silveira, Alexandre; de Lima, João L. M. P.

    2018-02-01

    The accurate measurement of shallow flow velocities is crucial to understand and model the dynamics of sediment and pollutant transport by overland flow. In this study, a novel triple-tracer approach was used to re-evaluate and compare the traditional and well established dye and salt tracer techniques with the more recent thermal tracer technique in estimating shallow flow velocities. For this purpose a triple tracer (i.e. dyed-salted-heated water) was used. Optical and infrared video cameras and an electrical conductivity sensor were used to detect the tracers in the flow. Leading edge and centroid velocities of the tracers were measured and the correction factors used to determine the actual mean flow velocities from tracer measured velocities were compared and investigated. Experiments were carried out for different flow discharges (32-1813 ml s-1) on smooth acrylic, sand, stones and synthetic grass bed surfaces with 0.8, 4.4 and 13.2% slopes. The results showed that thermal tracers can be used to estimate shallow flow velocities, since the three techniques yielded very similar results without significant differences between them. The main advantages of the thermal tracer were that the movement of the tracer along the measuring section was more easily visible than it was in the real image videos and that it was possible to measure space-averaged flow velocities instead of only one velocity value, with the salt tracer. The correction factors used to determine the actual mean velocity of overland flow varied directly with Reynolds and Froude numbers, flow velocity and slope and inversely with flow depth and bed roughness. In shallow flows, velocity estimation using tracers entails considerable uncertainty and caution must be taken with these measurements, especially in field studies where these variables vary appreciably in space and time.

  20. Tuning structure and mobility of solvation shells surrounding tracer additives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carmer, James; Jain, Avni; Bollinger, Jonathan A.

    2015-03-28

    Molecular dynamics simulations and a stochastic Fokker-Planck equation based approach are used to illuminate how position-dependent solvent mobility near one or more tracer particle(s) is affected when tracer-solvent interactions are rationally modified to affect corresponding solvation structure. For tracers in a dense hard-sphere fluid, we compare two types of tracer-solvent interactions: (1) a hard-sphere-like interaction, and (2) a soft repulsion extending beyond the hard core designed via statistical mechanical theory to enhance tracer mobility at infinite dilution by suppressing coordination-shell structure [Carmer et al., Soft Matter 8, 4083–4089 (2012)]. For the latter case, we show that the mobility of surroundingmore » solvent particles is also increased by addition of the soft repulsive interaction, which helps to rationalize the mechanism underlying the tracer’s enhanced diffusivity. However, if multiple tracer surfaces are in closer proximity (as at higher tracer concentrations), similar interactions that disrupt local solvation structure instead suppress the position-dependent solvent dynamics.« less

  1. Fractal continuum model for tracer transport in a porous medium.

    PubMed

    Herrera-Hernández, E C; Coronado, M; Hernández-Coronado, H

    2013-12-01

    A model based on the fractal continuum approach is proposed to describe tracer transport in fractal porous media. The original approach has been extended to treat tracer transport and to include systems with radial and uniform flow, which are cases of interest in geoscience. The models involve advection due to the fluid motion in the fractal continuum and dispersion whose mathematical expression is taken from percolation theory. The resulting advective-dispersive equations are numerically solved for continuous and for pulse tracer injection. The tracer profile and the tracer breakthrough curve are evaluated and analyzed in terms of the fractal parameters. It has been found in this work that anomalous transport frequently appears, and a condition on the fractal parameter values to predict when sub- or superdiffusion might be expected has been obtained. The fingerprints of fractality on the tracer breakthrough curve in the explored parameter window consist of an early tracer breakthrough and long tail curves for the spherical and uniform flow cases, and symmetric short tailed curves for the radial flow case.

  2. Comparison of different tracers for PIV measurements in EHD airflow

    NASA Astrophysics Data System (ADS)

    Hamdi, M.; Havet, M.; Rouaud, O.; Tarlet, D.

    2014-04-01

    In this study, a proposed method for selecting a tracer for particle imaging velocimetry (PIV) measurement in electrohydrodynamics flows was developed. To begin with, several published studies were identified that exploit different tracers, such as oil smoke, cigarette smoke and titanium dioxide (TiO2). An assortment of tracers was then selected based on comparisons with conventional dimensionless numbers; Stokes number ( St), Archimedes number ( Ar) and electrical mobility ratio ( M). Subsequently, an experimental study for testing tracers was developed, which enabled the velocity profile of an ionic wind generated by a needle/ring configuration to be measured. Air velocity measurements carried out with a Pitot tube, considered as the reference measurements, were compared to PIV measurements for each tracer. In addition, the current-voltage curves and the evolution of the current during seeding were measured. All the experimental results show that TiO2, SiO2 microballoons and incense smoke are the ideal tracers in the series of tracers investigated.

  3. Impacts of Siberian biomass burning on organic aerosols over the North Pacific Ocean and the Arctic: primary and secondary organic tracers.

    PubMed

    Ding, Xiang; Wang, Xinming; Xie, Zhouqing; Zhang, Zhou; Sun, Liguang

    2013-04-02

    During the 2003 Chinese Arctic Research Expedition (CHINARE2003) from the Bohai Sea to the high Arctic (37°N-80°N), filter-based particle samples were collected and analyzed for tracers of primary and secondary organic aerosols (SOA) as well as water-soluble organic carbon (WSOC). Biomass burning (BB) tracer levoglucosan had comparatively much higher summertime average levels (476 ± 367 pg/m(3)) during our cruise due to the influence of intense forest fires then in Siberia. On the basis of 5-day back trajectories, samples with air masses passing through Siberia had organic tracers 1.3-4.4 times of those with air masses transporting only over the oceans, suggesting substantial contribution of continental emissions to organic aerosols in the marine atmosphere. SOA tracers from anthropogenic aromatics were negligible or not detected, while those from biogenic terpenenoids were ubiquitously observed with the sum of SOA tracers from isoprene (623 ± 414 pg/m(3)) 1 order of magnitude higher than that from monoterpenes (63 ± 49 pg/m(3)). 2-Methylglyceric acid as a product of isoprene oxidation under high-NOx conditions was dominant among SOA tracers, implying that these BSOA tracers were not formed over the oceans but mainly transported from the adjacent Siberia where a high-NOx environment could be induced by intense forest fires. The carbon fractions shared by biogenic SOA tracers and levoglucosan in WSOC in our ocean samples were 1-2 orders of magnitude lower than those previously reported in continental samples, BB emissions or chamber simulation samples, largely due to the chemical evolution of organic tracers during transport. As a result of the much faster decline in levels of organic tracers than that of WSOC during transport, the trace-based approach, which could well reconstruct WSOC using biogenic SOA and BB tracers for continental samples, only explained ∼4% of measured WSOC during our expedition if the same tracer-WSOC or tracer-SOC relationships were applied.

  4. Dual-tracer background subtraction approach for fluorescent molecular tomography

    PubMed Central

    Holt, Robert W.; El-Ghussein, Fadi; Davis, Scott C.; Samkoe, Kimberley S.; Gunn, Jason R.; Leblond, Frederic

    2013-01-01

    Abstract. Diffuse fluorescence tomography requires high contrast-to-background ratios to accurately reconstruct inclusions of interest. This is a problem when imaging the uptake of fluorescently labeled molecularly targeted tracers in tissue, which can result in high levels of heterogeneously distributed background uptake. We present a dual-tracer background subtraction approach, wherein signal from the uptake of an untargeted tracer is subtracted from targeted tracer signal prior to image reconstruction, resulting in maps of targeted tracer binding. The approach is demonstrated in simulations, a phantom study, and in a mouse glioma imaging study, demonstrating substantial improvement over conventional and homogenous background subtraction image reconstruction approaches. PMID:23292612

  5. A novel fluorine-18 β-fluoroethoxy organophosphate positron emission tomography imaging tracer targeted to central nervous system acetylcholinesterase.

    PubMed

    James, Shelly L; Ahmed, S Kaleem; Murphy, Stephanie; Braden, Michael R; Belabassi, Yamina; VanBrocklin, Henry F; Thompson, Charles M; Gerdes, John M

    2014-07-16

    Radiosynthesis of a fluorine-18 labeled organophosphate (OP) inhibitor of acetylcholinesterase (AChE) and subsequent positron emission tomography (PET) imaging using the tracer in the rat central nervous system are reported. The tracer structure, which contains a novel β-fluoroethoxy phosphoester moiety, was designed as an insecticide-chemical nerve agent hybrid to optimize handling and the desired target reactivity. Radiosynthesis of the β-fluoroethoxy tracer is described that utilizes a [(18)F]prosthetic group coupling approach. The imaging utility of the [(18)F]tracer is demonstrated in vivo within rats by the evaluation of its brain penetration and cerebral distribution qualities in the absence and presence of a challenge agent. The tracer effectively penetrates brain and localizes to cerebral regions known to correlate with the expression of the AChE target. Brain pharmacokinetic properties of the tracer are consistent with the formation of an OP-adducted acetylcholinesterase containing the fluoroethoxy tracer group. Based on the initial favorable in vivo qualities found in rat, additional [(18)F]tracer studies are ongoing to exploit the technology to dynamically probe organophosphate mechanisms of action in mammalian live tissues.

  6. New Applications of Cosmogenic Radioactive Isotopes to Study Water Travel Times

    NASA Astrophysics Data System (ADS)

    Visser, A.; Thaw, M.; Deinhart, A.; Bibby, R. K.; Esser, B.

    2017-12-01

    The travel time of water moving through a landscape influences nutrient dynamics and biogeochemical cycles. Constraining water travel times helps to understand the functioning of the critical zone. Water travel times cannot be observed directly but can be constrained by measurements of cosmogenic radioactive isotopes. We studied a small (4.6 km2) subalpine (1660-2117 m) catchment in a Mediterranean climate (8 °C, 1200 mm/yr) in the California Sierra Nevada to assess subsurface water storage dynamics and investigate flow paths and flow velocities. We analyzed a combination of three cosmogenic radioactive isotopes with half-lives varying from 87 days (sulfur-35), 2.6 years (sodium-22) to 12.3 years (tritium) in precipitation and stream samples. Water stable isotopes and solute chemistry aided the interpretation of the cosmogenic isotopes. Tritium samples (1L) are analyzed by noble gas mass spectrometry after helium-3 accumulation. Samples for sulfur-35 and sodium-22 are collected by processing 20-1000 L of water through an anion and cation exchange column in-situ. Sulfur-35 is analyzed by liquid scintillation counting after chemical purification and precipitation. Sodium-22 is analyzed by gamma counting after eluting the cations into a 4L Marinelli beaker. Monthly collected precipitation samples show variability of deposition rate for tritium and sulfur-35. Sodium-22 levels in cumulative yearly precipitation samples are consistent with recent studies in the US and Japan. The observed variability of deposition rates complicates direct use as decaying age tracers. The level and variability of tritium in monthly stream samples indicate a mean residence time on the order of 10 years and only small contributions of younger water during high flow conditions. Sulfur-35 and sodium-22 concentrations were critically interpreted considering possible uptake by vegetation and cation exchange. Detections of sodium-22 confirm a small fraction of younger (< 5 years) water. Low concentrations of sulfur-35 suggest very small contributions of same-year snowmelt or precipitation. Results from two contrasting years (severe drought in 2015 and near-normal conditions in 2016) illustrate travel time responses to hydrological conditions and further characterize the catchment properties.

  7. Water movement in the unsaturated zone at a low-level radioactive-waste burial site near Barnwell, South Carolina

    USGS Publications Warehouse

    Dennehy, K.F.; McMahon, P.B.

    1987-01-01

    Four unsaturated zone monitoring sites and a meteorologic station were installed at the low level radioactive waste burial site near Barnwell, South Carolina, to investigate the geohydrologic and climatologic factors affecting water movement in the unsaturated zone. The study site is located in the Atlantic Coastal Plain. The unsaturated zone consists of a few centimeters to > 1 m of surface sand, underlain by up to 15 m of clayey sand. Two monitoring sites were installed in experimental trenches and two were installed in radioactive waste trenches. Two different trench designs were evaluated at the monitoring sites. A meteorologic station was used to measure precipitation and to calculate actual evapotranspiration using the Bowen ratio method. Soil-moisture tensiometers, soil-moisture conductance probes, and temperature sensors were used to monitor soil-water movement in and adjacent to the trenches. Tracer tests using sodium chloride were conducted at each monitoring site. Data collection at the monitoring sites began in January 1982 and continued until early May 1984. Tensiometer data show that the unsaturated materials had their highest percent saturations in the winter and spring. Saturations in the backfill sand varied from 20 to 100%. They varied from about 75 to 100% in the adjacent undisturbed and overlying compacted clayey sand. Additionally, because tensiometer data indicate negligible water storage changes in the unsaturated zone, it is estimated that approximately 43 cm of recharge reached the water table. During 1984, the rise and fall of ponded water in an experimental trench was continuously monitored with a digital recorder. A cross-sectional finite element model of variably saturated flow was used to test the conceptual model of water movement in the unsaturated zone and to illustrate the effect of trench design on water movement into the experimental trenches. Monitoring and model results show that precipitation on trenches infiltrated the trench cap and moved vertically into the trench backfill material. The trench construction practice of placing a compacted clayey-sand barrier around the trench greatly inhibits soil water from entering the trench. (Author 's abstract)

  8. Synthesis and preliminary biological evaluation of S-11C-methyl-D-cysteine as a new amino acid PET tracer for cancer imaging.

    PubMed

    Huang, Tingting; Tang, Ganghua; Wang, Hongliang; Nie, Dahong; Tang, Xiaolan; Liang, Xiang; Hu, Kongzhen; Yi, Chang; Yao, Baoguo; Tang, Caihua

    2015-04-01

    S-(11)C-methyl-L-cysteine (LMCYS) is an attractive amino acid tracer for clinical tumor positron emission tomography (PET) imaging. D-isomers of some radiolabeled amino acids are potential PET tracers for tumor imaging. In this work, S-(11)C-methyl-D-cysteine (DMCYS), a D-amino acid isomer of S-(11)C-methyl-cysteine for tumor imaging was developed and evaluated. DMCYS was prepared by (11)C-methylation of the precursor D-cysteine, with an uncorrected radiochemical yield over 50 % from (11)CH3I within a total synthesis time from (11)CO2 about 12 min. In vitro competitive inhibition studies showed that DMCYS uptake was primarily transported through the Na(+)-independent system L, and also the Na(+)-dependent system B(0,+) and system ASC, with almost no system A. In vitro incorporation experiments indicated that almost no protein incorporation was found in Hepa 1-6 hepatoma cell lines. Biodistribution studies demonstrated higher uptake of DMCYS in pancreas and liver at 5 min post-injection, relatively lower uptake in brain and muscle, and faster radioactivity clearance from most tissues than those of L-isomer during the entire observation time. In the PET imaging of S180 fibrosarcoma-bearing mice and turpentine-induced inflammatory model mice, 2-(18)F-fluoro-2-deoxy-D-glucose (FDG) exhibited significantly high accumulation in both tumor and inflammatory lesion with low tumor-to-inflammation ratio of 1.40, and LMCYS showed low tumor-to-inflammation ratio of 1.64 at 60 min post-injection. By contrast, DMCYS showed moderate accumulation in tumor and very low uptake in inflammatory lesion, leading to relatively higher tumor-to-inflammation ratio of 2.25 than (11)C-methyl-L-methionine (MET) (1.85) at 60 min post-injection. Also, PET images of orthotopic transplanted glioma models demonstrated that low uptake of DMCYS in normal brain tissue and high uptake in brain glioma tissue were observed. The results suggest that DMCYS is a little better than the corresponding L-isomers as a potential PET tumor-detecting agent and is superior to MET and FDG in the differentiation of tumor from inflammation.

  9. The Effect of Body Posture on Brain Glymphatic Transport.

    PubMed

    Lee, Hedok; Xie, Lulu; Yu, Mei; Kang, Hongyi; Feng, Tian; Deane, Rashid; Logan, Jean; Nedergaard, Maiken; Benveniste, Helene

    2015-08-05

    The glymphatic pathway expedites clearance of waste, including soluble amyloid β (Aβ) from the brain. Transport through this pathway is controlled by the brain's arousal level because, during sleep or anesthesia, the brain's interstitial space volume expands (compared with wakefulness), resulting in faster waste removal. Humans, as well as animals, exhibit different body postures during sleep, which may also affect waste removal. Therefore, not only the level of consciousness, but also body posture, might affect CSF-interstitial fluid (ISF) exchange efficiency. We used dynamic-contrast-enhanced MRI and kinetic modeling to quantify CSF-ISF exchange rates in anesthetized rodents' brains in supine, prone, or lateral positions. To validate the MRI data and to assess specifically the influence of body posture on clearance of Aβ, we used fluorescence microscopy and radioactive tracers, respectively. The analysis showed that glymphatic transport was most efficient in the lateral position compared with the supine or prone positions. In the prone position, in which the rat's head was in the most upright position (mimicking posture during the awake state), transport was characterized by "retention" of the tracer, slower clearance, and more CSF efflux along larger caliber cervical vessels. The optical imaging and radiotracer studies confirmed that glymphatic transport and Aβ clearance were superior in the lateral and supine positions. We propose that the most popular sleep posture (lateral) has evolved to optimize waste removal during sleep and that posture must be considered in diagnostic imaging procedures developed in the future to assess CSF-ISF transport in humans. The rodent brain removes waste better during sleep or anesthesia compared with the awake state. Animals exhibit different body posture during the awake and sleep states, which might affect the brain's waste removal efficiency. We investigated the influence of body posture on brainwide transport of inert tracers of anesthetized rodents. The major finding of our study was that waste, including Aβ, removal was most efficient in the lateral position (compared with the prone position), which mimics the natural resting/sleeping position of rodents. Although our finding awaits testing in humans, we speculate that the lateral position during sleep has advantage with regard to the removal of waste products including Aβ, because clinical studies have shown that sleep drives Aβ clearance from the brain. Copyright © 2015 the authors 0270-6474/15/3511034-11$15.00/0.

  10. Micro Regional Heterogeneity of 64Cu-ATSM and 18F-FDG Uptake in Canine Soft Tissue Sarcomas: Relation to Cell Proliferation, Hypoxia and Glycolysis.

    PubMed

    Zornhagen, Kamilla Westarp; Hansen, Anders E; Oxboel, Jytte; Clemmensen, Andreas E; El Ali, Henrik H; Kristensen, Annemarie T; Kjær, Andreas

    2015-01-01

    Tumour microenvironment heterogeneity is believed to play a key role in cancer progression and therapy resistance. However, little is known about micro regional distribution of hypoxia, glycolysis and proliferation in spontaneous solid tumours. The overall aim was simultaneous investigation of micro regional heterogeneity of 64Cu-ATSM (hypoxia) and 18F-FDG (glycolysis) uptake and correlation to endogenous markers of hypoxia, glycolysis, proliferation and angiogenesis to better therapeutically target aggressive tumour regions and prognosticate outcome. Exploiting the different half-lives of 64Cu-ATSM (13 h) and 18F-FDG (2 h) enabled simultaneous investigation of micro regional distribution of hypoxia and glycolysis in 145 tumour pieces from four spontaneous canine soft tissue sarcomas. Pairwise measurements of radioactivity and gene expression of endogenous markers of hypoxia (HIF-1α, CAIX), glycolysis (HK2, GLUT1 and GLUT3), proliferation (Ki-67) and angiogenesis (VEGFA and TF) were performed. Dual tracer autoradiography was compared with Ki-67 immunohistochemistry. Micro regional heterogeneity in hypoxia and glycolysis within and between tumour sections of each tumour piece was observed. The spatial distribution of 64Cu-ATSM and 18F-FDG was rather similar within each tumour section as reflected in moderate positive significant correlations between the two tracers (ρ = 0.3920-0.7807; p = 0.0180 -<0.0001) based on pixel-to-pixel comparisons of autoradiographies and gamma counting of tumour pieces. 64Cu-ATSM and 18F-FDG correlated positively with gene expression of GLUT1 and GLUT3, but negatively with HIF-1α and CAIX. Significant positive correlations were seen between Ki-67 gene expression and 64Cu-ATSM (ρ = 0.5578, p = 0.0004) and 18F-FDG (ρ = 0.4629-0.7001, p = 0.0001-0.0151). Ki-67 gene expression more consistently correlated with 18F-FDG than with 64Cu-ATSM. Micro regional heterogeneity of hypoxia and glycolysis was documented in spontaneous canine soft tissue sarcomas. 64Cu-ATSM and 18F-FDG uptakes and distributions showed significant moderate correlations at the micro regional level indicating overlapping, yet different information from the tracers.18F-FDG better reflected cell proliferation as measured by Ki-67 gene expression than 64Cu-ATSM.

  11. Small-animal PET study of adenosine A(1) receptors in rat brain: blocking receptors and raising extracellular adenosine.

    PubMed

    Paul, Soumen; Khanapur, Shivashankar; Rybczynska, Anna A; Kwizera, Chantal; Sijbesma, Jurgen W A; Ishiwata, Kiichi; Willemsen, Antoon T M; Elsinga, Philip H; Dierckx, Rudi A J O; van Waarde, Aren

    2011-08-01

    Activation of adenosine A(1) receptors (A(1)R) in the brain causes sedation, reduces anxiety, inhibits seizures, and promotes neuroprotection. Cerebral A(1)R can be visualized using 8-dicyclopropylmethyl-1-(11)C-methyl-3-propyl-xanthine ((11)C-MPDX) and PET. This study aims to test whether (11)C-MPDX can be used for quantitative studies of cerebral A(1)R in rodents. (11)C-MPDX was injected (intravenously) into isoflurane-anesthetized male Wistar rats (300 g). A dynamic scan of the central nervous system was obtained, using a small-animal PET camera. A cannula in a femoral artery was used for blood sampling. Three groups of animals were studied: group 1, controls (saline-treated); group 2, animals pretreated with the A(1)R antagonist 8-cyclopentyl-1,3-dipropylxanthine (DPCPX, 1 mg, intraperitoneally); and group 3, animals pretreated (intraperitoneally) with a 20% solution of ethanol in saline (2 mL) plus the adenosine kinase inhibitor 4-amino-5-(3-bromophenyl)-7-(6-morpholino-pyridin-3-yl)pyrido[2,3-d] pyrimidine dihydrochloride (ABT-702) (1 mg). DPCPX is known to occupy cerebral A(1)R, whereas ethanol and ABT-702 increase extracellular adenosine. In groups 1 and 3, the brain was clearly visualized. High uptake of (11)C-MPDX was noted in striatum, hippocampus, and cerebellum. In group 2, tracer uptake was strongly suppressed and regional differences were abolished. The treatment of group 3 resulted in an unexpected 40%-45% increase of the cerebral uptake of radioactivity as indicated by increases of PET standardized uptake value, distribution volume from Logan plot, nondisplaceable binding potential from 2-tissue-compartment model fit, and standardized uptake value from a biodistribution study performed after the PET scan. The partition coefficient of the tracer (K(1)/k(2) from the model fit) was not altered under the study conditions. (11)C-MPDX shows a regional distribution in rat brain consistent with binding to A(1)R. Tracer binding is blocked by the selective A(1)R antagonist DPCPX. Pretreatment of animals with ethanol and adenosine kinase inhibitor increases (11)C-MPDX uptake. This increase may reflect an increased availability of A(1)R after acute exposure to ethanol.

  12. Hybrid Surgical Guidance: Does Hardware Integration of γ- and Fluorescence Imaging Modalities Make Sense?

    PubMed

    KleinJan, Gijs H; Hellingman, Daan; van den Berg, Nynke S; van Oosterom, Matthias N; Hendricksen, Kees; Horenblas, Simon; Valdes Olmos, Renato A; van Leeuwen, Fijs Wb

    2017-04-01

    The clinically applied hybrid tracer indocyanine green- 99m Tc-nanocolloid enables combined radio- and fluorescence image guidance during sentinel node (SN) biopsy procedures. To provide optimal surgical guidance, this tracer requires the presence of both γ- and fluorescence modalities in the operating room. We reasoned that the combination or integration of these modalities could further evolve the hybrid surgical guidance concept. To study this potential, we clinically applied 2 setups that included the combination of γ-detection modalities and an open surgery fluorescence camera. Methods: To attach the fluorescence camera (VITOM) to either a γ-ray detection probe (GP; VITOM-GP) or a portable γ-camera (GC; Vitom GC), clip-on brackets were designed and printed in 3-dimensional sterilizable RC31. Both combined modalities were evaluated in, respectively, 5 and 6 patients with penile cancer during an SN biopsy procedure using indocyanine green- 99m Tc-nanocolloid. Intraoperatively, radio- and fluorescence-guided SN detection rates were scored at working distances of 0, 10, 20, and 30 cm for both combinations. Results: Using the VITOM-GP combination, we evaluated 9 SNs. γ-tracing rates were shown to be 100%, 88.9%, 55.6%, and 55.6% at a respective working distance of 0, 10, 20, and 30 cm. Detection rates for the fluorescence imaging-based detection were found to be 100%, 77.8%, and 77.8%, at respective working distances of 10, 20, and 30 cm. When the VITOM-GC setup was used, all 10 intraoperatively evaluated SNs could be visualized with the γ-camera independent of the working distance. Fluorescence detection rates were 90%, 80%, and 80% at 10-, 20-, and 30-cm working distances. The integrated detection modalities were shown to work synergistically; overall the, GC was most valuable for rough localization (10- to 30-cm range) of the SNs, the GP for providing convenient real-time acoustic feedback, whereas fluorescence guidance allowed detailed real-time SN visualization. Conclusion: Our findings suggest that full integration of a fluorescence camera with γ-detector (GP or GC) can be of value when a hybrid, radioactive and fluorescent tracer is used. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  13. Micro Regional Heterogeneity of 64Cu-ATSM and 18F-FDG Uptake in Canine Soft Tissue Sarcomas: Relation to Cell Proliferation, Hypoxia and Glycolysis

    PubMed Central

    Zornhagen, Kamilla Westarp; Hansen, Anders E.; Oxboel, Jytte; Clemmensen, Andreas E.; El Ali, Henrik H.; Kristensen, Annemarie T.; Kjær, Andreas

    2015-01-01

    Objectives Tumour microenvironment heterogeneity is believed to play a key role in cancer progression and therapy resistance. However, little is known about micro regional distribution of hypoxia, glycolysis and proliferation in spontaneous solid tumours. The overall aim was simultaneous investigation of micro regional heterogeneity of 64Cu-ATSM (hypoxia) and 18F-FDG (glycolysis) uptake and correlation to endogenous markers of hypoxia, glycolysis, proliferation and angiogenesis to better therapeutically target aggressive tumour regions and prognosticate outcome. Methods Exploiting the different half-lives of 64Cu-ATSM (13h) and 18F-FDG (2h) enabled simultaneous investigation of micro regional distribution of hypoxia and glycolysis in 145 tumour pieces from four spontaneous canine soft tissue sarcomas. Pairwise measurements of radioactivity and gene expression of endogenous markers of hypoxia (HIF-1α, CAIX), glycolysis (HK2, GLUT1 and GLUT3), proliferation (Ki-67) and angiogenesis (VEGFA and TF) were performed. Dual tracer autoradiography was compared with Ki-67 immunohistochemistry. Results Micro regional heterogeneity in hypoxia and glycolysis within and between tumour sections of each tumour piece was observed. The spatial distribution of 64Cu-ATSM and 18F-FDG was rather similar within each tumour section as reflected in moderate positive significant correlations between the two tracers (ρ = 0.3920–0.7807; p = 0.0180 –<0.0001) based on pixel-to-pixel comparisons of autoradiographies and gamma counting of tumour pieces. 64Cu-ATSM and 18F-FDG correlated positively with gene expression of GLUT1 and GLUT3, but negatively with HIF-1α and CAIX. Significant positive correlations were seen between Ki-67 gene expression and 64Cu-ATSM (ρ = 0.5578, p = 0.0004) and 18F-FDG (ρ = 0.4629–0.7001, p = 0.0001–0.0151). Ki-67 gene expression more consistently correlated with 18F-FDG than with 64Cu-ATSM. Conclusions Micro regional heterogeneity of hypoxia and glycolysis was documented in spontaneous canine soft tissue sarcomas. 64Cu-ATSM and 18F-FDG uptakes and distributions showed significant moderate correlations at the micro regional level indicating overlapping, yet different information from the tracers.18F-FDG better reflected cell proliferation as measured by Ki-67 gene expression than 64Cu-ATSM. PMID:26501874

  14. N-(4-[18F]fluorobenzyl)cholylglycine, a novel tracer for PET of enterohepatic circulation of bile acids: Radiosynthesis and proof-of-concept studies in rats.

    PubMed

    Frisch, Kim; Stimson, Damion H R; Venkatachalam, Taracad; Pierens, Gregory K; Keiding, Susanne; Reutens, David; Bhalla, Rajiv

    2018-05-04

    Enterohepatic circulation (EHC) of conjugated bile acids is an important physiological process crucial for regulation of intracellular concentrations of bile acids and their function as detergents and signal carriers. Only few bile acid-derived imaging agents have been synthesized and hitherto none have been evaluated for studies of EHC. We hypothesized that N-(4-[ 18 F]fluorobenzyl)cholylglycine ([ 18 F]FBCGly), a novel fluorine-18 labeled derivative of endogenous cholylglycine, would be a suitable tracer for PET of the EHC of conjugated bile acids, and we report here a radiosynthesis of [ 18 F]FBCGly and a proof-of-concept study by PET/MR in rats. A radiosynthesis of [ 18 F]FBCGly was developed based on reductive alkylation of glycine with 4-[ 18 F]fluorobenzaldehyde followed by coupling to cholic acid. [ 18 F]FBCGly was investigated in vivo by dynamic PET/MR in anesthetized rats; untreated or treated with cholyltaurine or rifampicin. Possible in vivo metabolites of [ 18 F]FBCGly were investigated by analysis of blood and bile samples, and the stability of [ 18 F]FBCGly towards enzymatic de-conjugation by Cholylglycine Hydrolase was tested in vitro. [ 18 F]FBCGly was produced with a radiochemical purity of 96% ± 1% and a non-decay corrected radiochemical yield of 1.0% ± 0.3% (mean ± SD; n = 12). PET/MR studies showed that i.v.-administrated [ 18 F]FBCGly underwent EHC within 40-60 min with a rapid transhepatic transport from blood to bile. In untreated rats, the radioactivity concentration of [ 18 F]FBCGly was approximately 15 times higher in bile than in liver tissue. Cholyltaurine and rifampicin inhibited the biliary secretion of [ 18 F]FBCGly. No fluorine-18 metabolites of [ 18 F]FBCGly were observed. We have developed a radiosynthesis of a novel fluorine-18 labeled bile acid derivative, [ 18 F]FBCGly, and shown by PET/MR that [ 18 F]FBCGly undergoes continuous EHC in rats without metabolizing. This novel tracer may prove useful in PET studies on the effect of drugs or diseases on the EHC of conjugated bile acids. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. The Effect of Body Posture on Brain Glymphatic Transport

    PubMed Central

    Lee, Hedok; Xie, Lulu; Yu, Mei; Kang, Hongyi; Feng, Tian; Deane, Rashid; Logan, Jean; Nedergaard, Maiken

    2015-01-01

    The glymphatic pathway expedites clearance of waste, including soluble amyloid β (Aβ) from the brain. Transport through this pathway is controlled by the brain's arousal level because, during sleep or anesthesia, the brain's interstitial space volume expands (compared with wakefulness), resulting in faster waste removal. Humans, as well as animals, exhibit different body postures during sleep, which may also affect waste removal. Therefore, not only the level of consciousness, but also body posture, might affect CSF–interstitial fluid (ISF) exchange efficiency. We used dynamic-contrast-enhanced MRI and kinetic modeling to quantify CSF-ISF exchange rates in anesthetized rodents' brains in supine, prone, or lateral positions. To validate the MRI data and to assess specifically the influence of body posture on clearance of Aβ, we used fluorescence microscopy and radioactive tracers, respectively. The analysis showed that glymphatic transport was most efficient in the lateral position compared with the supine or prone positions. In the prone position, in which the rat's head was in the most upright position (mimicking posture during the awake state), transport was characterized by “retention” of the tracer, slower clearance, and more CSF efflux along larger caliber cervical vessels. The optical imaging and radiotracer studies confirmed that glymphatic transport and Aβ clearance were superior in the lateral and supine positions. We propose that the most popular sleep posture (lateral) has evolved to optimize waste removal during sleep and that posture must be considered in diagnostic imaging procedures developed in the future to assess CSF-ISF transport in humans. SIGNIFICANCE STATEMENT The rodent brain removes waste better during sleep or anesthesia compared with the awake state. Animals exhibit different body posture during the awake and sleep states, which might affect the brain's waste removal efficiency. We investigated the influence of body posture on brainwide transport of inert tracers of anesthetized rodents. The major finding of our study was that waste, including Aβ, removal was most efficient in the lateral position (compared with the prone position), which mimics the natural resting/sleeping position of rodents. Although our finding awaits testing in humans, we speculate that the lateral position during sleep has advantage with regard to the removal of waste products including Aβ, because clinical studies have shown that sleep drives Aβ clearance from the brain. PMID:26245965

  16. Chemical Tool Peer Review Summary.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cashion, Avery Ted; Cieslewski, Grzegorz

    Chemical tracers are commonly used to characterize fracture networks and to determine the connectivity between the injection and production wells. Currently, most tracer experiments involve injecting the tracer at the injection well, manually collecting liquid samples at the wellhead of the production well, and sending the samples off for laboratory analysis. While this method provides accurate tracer concentration data, it does not provide information regarding the location of the fractures conducting the tracer between wellbores. The goal of this project is to develop chemical sensors and design a prototype tool to help understand the fracture properties of a geothermal reservoirmore » by monitoring tracer concentrations along the depth of the well. The sensors will be able to detect certain species of the ionic tracers (mainly iodide) and pH in-situ during the tracer experiment. The proposed high-temperature (HT) tool will house the chemical sensors as well as a standard logging sensor package of pressure, temperature, and flow sensors in order to provide additional information on the state of the geothermal reservoir. The sensors and the tool will be able to survive extended deployments at temperatures up to 225 °C and high pressures to provide real-time temporal and spatial feedback of tracer concentration. Data collected from this tool will allow for the real-time identification of the fractures conducting chemical tracers between wellbores along with the pH of the reservoir fluid at various depths.« less

  17. AN INTEGRATED APPROACH TO CHARACTERIZING BYPASSED OIL IN HETEROGENEOUS AND FRACTURED RESERVOIRS USING PARTITIONING TRACERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akhil Datta-Gupta

    2003-08-01

    We explore the use of efficient streamline-based simulation approaches for modeling partitioning interwell tracer tests in hydrocarbon reservoirs. Specifically, we utilize the unique features of streamline models to develop an efficient approach for interpretation and history matching of field tracer response. A critical aspect here is the underdetermined and highly ill-posed nature of the associated inverse problems. We have adopted an integrated approach whereby we combine data from multiple sources to minimize the uncertainty and non-uniqueness in the interpreted results. For partitioning interwell tracer tests, these are primarily the distribution of reservoir permeability and oil saturation distribution. A novel approachmore » to multiscale data integration using Markov Random Fields (MRF) has been developed to integrate static data sources from the reservoir such as core, well log and 3-D seismic data. We have also explored the use of a finite difference reservoir simulator, UTCHEM, for field-scale design and optimization of partitioning interwell tracer tests. The finite-difference model allows us to include detailed physics associated with reactive tracer transport, particularly those related with transverse and cross-streamline mechanisms. We have investigated the potential use of downhole tracer samplers and also the use of natural tracers for the design of partitioning tracer tests. Finally, the behavior of partitioning tracer tests in fractured reservoirs is investigated using a dual-porosity finite-difference model.« less

  18. NMED Correspondence Related to Notice of Intent for Chromium Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinez, Ellena Isabel

    Two methods of injection using a solution containing 50 kilograms (kg) of tracer are proposed for each well. Half of the tracer (25 kg) may be mixed with 3,000 gallons of potable water and delivered into a scheduled injection stream of treated groundwater as permitted in OP-1835 over a five to seven-hour period. This procedure would then be repeated on a consecutive second day. Alternatively, 5 kg of tracer may be added to each of ten 3,000-gallon tanks for a total of 30,000 gallons of tracer solution that may be injected independently of other injection flow over a period ofmore » up to five days. The permittees request that the types and masses of tracers that may be utilized per each injection well remain flexible enough to allow for one or more of the naphthalene sulfonate tracers to be substituted with a different naphthalene sulfonate. This need for flexibility is due to the availability of the tracers and any tracer listed that is designated for a given CrIN well may be interchanged with a tracer that is designated for another CrIN well, pending final NMED approval. The permittees are not allowed to introduce any new tracers and will submit a final work plan prior to each injection for each CrIN well.« less

  19. Effects of crude oil on water and tracer movement in the unsaturated and saturated zones.

    PubMed

    Delin, Geoffrey N; Herkelrath, William N

    2017-05-01

    A tracer test was conducted to aid in the investigation of water movement and solute transport at a crude-oil spill site near Bemidji, Minnesota. Time of travel was measured using breakthrough curves for rhodamine WT and bromide tracers moving from the soil surface through oil-contaminated and oil-free unsaturated zones to the saturated zone. Results indicate that the rates of tracer movement were similar in the oil-free unsaturated and saturated zones compared to the oily zones. These results are somewhat surprising given the oil contamination in the unsaturated and saturated zones. Rhodamine tracer breakthrough in the unsaturated and saturated zones in general was delayed in comparison to bromide tracer breakthrough. Peak tracer concentrations for the lysimeters and wells in the oily zone were much greater than at the corresponding depths in the oil-free zone. Water and tracer movement in the oily zone was complicated by soil hydrophobicity and decreased oil saturations toward the periphery of the oil. Preferential flow resulted in reduced tracer interaction with the soil, adsorption, and dispersion and faster tracer movement in the oily zone than expected. Tracers were freely transported through the oily zone to the water table. Recharge calculations support the idea that the oil does not substantially affect recharge in the oily zone. This is an important result indicating that previous model-based assumptions of decreased recharge beneath the oil were incorrect. Results have important implications for modeling the fate and transport of dissolved contaminants at hydrocarbon spill sites. Published by Elsevier B.V.

  20. Gaining insights into reactive fluid-fractured rock systems using the temporal moments of a tracer breakthrough curve.

    PubMed

    Mukhopadhyay, Sumit; Liu, H-H; Spycher, N; Kennedy, B M

    2014-03-01

    In this paper, we show that the tracer breakthrough curves (BTCs), when the tracer chemically interacts with the solid matrix of a fractured rock, are considerably different than when it does not. Of particular interest, is the presence of a long pseudo steady state zone in the BTCs, where the tracer concentration is more or less constant over a long period of time. However, such a zone of constant concentration is not visible when either the tracer does not interact with the solid, or does so at an extremely fast rate. We show that these characteristics of the BTCs could be correlated to the parameters of the system. We develop expressions for the mean residence time and its variance for a chemically active and inactive tracer. We show that chemical interaction between the tracer and the solid increases the mean residence time and the increase depends on the distribution coefficient. We also show that the variance of residence time for a chemically active tracer is much larger than that for an inactive tracer, and it depends on both the distribution coefficient and the rate of chemical reaction. We verify these calculations against synthetic tracer BTCs, where the temporal moments are calculated by numerically integrating the tracer evolution curves. Even though we developed the mathematical expressions assuming an idealized fracture-matrix system, we believe that the mathematical expressions developed in this paper can be useful in gaining insights into reactive transport in a real fractured rock system. Published by Elsevier B.V.

Top