Chambers, E.S.; Garren, A.A.; Kippenhan, D.O.; Lamb, W.A.S.; Riddell, R.J. Jr.
1960-01-01
The heating of ions in a magnetically confined plasma is accomplished by the application of an azimuthal radiofrequency electric field to the plasma at ion cyclotron resonance. The principal novelty resides in the provision of an output tank coil of a radiofrequency driver to induce the radiofrequency field in the plasma and of electron current bridge means at the ends of the plasma for suppressing radial polarization whereby the radiofrequency energy is transferred to the ions with high efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pasadas, Francisco, E-mail: Francisco.Pasadas@uab.cat; Jiménez, David
2015-12-28
Bilayer graphene is a promising material for radio-frequency transistors because its energy gap might result in a better current saturation than the monolayer graphene. Because the great deal of interest in this technology, especially for flexible radio-frequency applications, gaining control of it requires the formulation of appropriate models for the drain current, charge, and capacitance. In this work, we have developed them for a dual-gated bilayer graphene field-effect transistor. A drift-diffusion mechanism for the carrier transport has been considered coupled with an appropriate field-effect model taking into account the electronic properties of the bilayer graphene. Extrinsic resistances have been includedmore » considering the formation of a Schottky barrier at the metal-bilayer graphene interface. The proposed model has been benchmarked against experimental prototype transistors, discussing the main figures of merit targeting radio-frequency applications.« less
78 FR 33633 - Human Exposure to Radiofrequency Electromagnetic Fields
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-04
..., and 15, et al. Human Exposure to Radiofrequency Electromagnetic Fields; Reassessment of Exposure to Radiofrequency Electromagnetic Fields Limits and Policies; Final Rule and Proposed Rule #0;#0;Federal Register... Radiofrequency Electromagnetic Fields AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY...
Wenz, Daniel; Kuehne, Andre; Huelnhagen, Till; Nagel, Armin M; Waiczies, Helmar; Weinberger, Oliver; Oezerdem, Celal; Stachs, Oliver; Langner, Soenke; Seeliger, Erdmann; Flemming, Bert; Hodge, Russell; Niendorf, Thoralf
2018-08-01
The aim of this study was to achieve millimeter spatial resolution sodium in vivo MRI of the human eye at 7 T using a dedicated six-channel transceiver array. We present a detailed description of the radiofrequency coil design, along with electromagnetic field and specific absorption ratio simulations, data validation, and in vivo application. Electromagnetic field and specific absorption ratio simulations were performed. Transmit field uniformity was optimized by using a multi-objective genetic algorithm. Transmit field mapping was conducted using a phase-sensitive method. An in vivo feasibility study was carried out with 3-dimensional density-adapted projection reconstruction imaging technique. Measured transmit field distribution agrees well with the one obtained from simulations. The specific absorption ratio simulations confirm that the radiofrequency coil is safe for clinical use. Our radiofrequency coil is light and conforms to an average human head. High spatial resolution (nominal 1.4 and 1.0 mm isotropic) sodium in vivo images of the human eye were acquired within scan times suitable for clinical applications (∼ 10 min). Three most important eye compartments in the context of sodium physiology were clearly delineated in all of the images: the vitreous humor, the aqueous humor, and the lens. Our results provide encouragement for further clinical studies. The implications for research into eye diseases including ocular melanoma, cataract, and glaucoma are discussed. Magn Reson Med 80:672-684, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohsen, O.; Gonin, I.; Kephart, R.
High-power electron beams are sought-after tools in support to a wide array of societal applications. This paper investigates the production of high-power electron beams by combining a high-current field-emission electron source to a superconducting radio-frequency (SRF) cavity. We especially carry out beam-dynamics simulations that demonstrate the viability of the scheme to formmore » $$\\sim$$ 300 kW average-power electron beam using a 1+1/2-cell SRF gun.« less
DOUBLE ENDOR with a linearly and a circularly polarized radiofrequency field
NASA Astrophysics Data System (ADS)
Schweiger, A.; Rudin, M.; Forrer, J.; Günthard, Hs. H.
The combination of the two spectroscopical techniques, DOUBLE ENDOR and ENDOR with a circularly polarized radiofrequency field (CP-ENDOR), is described. with this new method, termed by the acronym CP-DOUBLE ENDOR, the selective induction of transitions of different types of nuclei and of different paramagnetic species allows a drastic reduction of the number of observed ENDOR lines. With this technique, analysis of hitherto not interpretable ENDOR spectra is often made possible. The experimental setup of the CP-DOUBLE ENDOR spectrometer is described. The advantage of using circularly polarized rf fields in DOUBLE ENDOR spectroscopy is illustrated by two applications on transition metal complexes in single crystals.
Radio-Frequency Applications for Food Processing and Safety.
Jiao, Yang; Tang, Juming; Wang, Yifen; Koral, Tony L
2018-03-25
Radio-frequency (RF) heating, as a thermal-processing technology, has been extending its applications in the food industry. Although RF has shown some unique advantages over conventional methods in industrial drying and frozen food thawing, more research is needed to make it applicable for food safety applications because of its complex heating mechanism. This review provides comprehensive information regarding RF-heating history, mechanism, fundamentals, and applications that have already been fully developed or are still under research. The application of mathematical modeling as a useful tool in RF food processing is also reviewed in detail. At the end of the review, we summarize the active research groups in the RF food thermal-processing field, and address the current problems that still need to be overcome.
NASA Astrophysics Data System (ADS)
Windl, Roman; Abert, Claas; Bruckner, Florian; Huber, Christian; Vogler, Christoph; Weitensfelder, Herbert; Suess, Dieter
2017-11-01
Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.
Disinfection of wastewater effluents with the Fenton-like process induced by electromagnetic fields.
Rodríguez-Chueca, J; Mediano, A; Ormad, M P; Mosteo, R; Ovelleiro, J L
2014-09-01
This research work is focused on the application and assessment of effectiveness of the Fenton-like processes induced by radiofrequency for the inactivation of faecal bacteria (Escherichia coli and Enterococcus sp.) present in treated urban wastewater effluents. Fenton processes were carried out at near neutral pH (pH 5) with different iron sources, such as iron salts (ferric chloride, 5, 50 and 100 mg/L Fe(3+)), magnetite (1 g/L) and clay (80 g/L), hydrogen peroxide (25 mg/L) and in absence and presence of radiofrequency. Two different electromagnetic field intensities (1.57 and 3.68 kA/m) were used in Fenton processes induced by radiofrequency. Different agents used in the Fenton processes induced by electromagnetic fields (iron source, hydrogen peroxide and RF) were analyzed individually and in combination under the same experimental conditions. First assays of ferromagnetic material/H2O2/radiofrequency processes achieved promising results in terms of bacterial inactivation. For instance, Fe(3+)/H2O2/Radiofrequency achieved a maximum level of E. coli inactivation of 3.55 log after 10 min of treatment. These results are higher than those obtained in absence of radiofrequency. The thermal activation of iron atoms allows the Fenton reaction to intensify, increasing the final yield of the treatment. On the other hand, different behavior was observed in the inactivation of E. coli and Enterococcus sp. due to the structural differences between Gram-negative and Gram-positive bacteria. Copyright © 2014 Elsevier Ltd. All rights reserved.
2014-01-01
Although exposure to electromagnetic radiation in radiofrequency range has caused a great deal of concern globally, radiofrequency radiation has many critical applications in both telecommunication and non-communication fields. The induction of adaptive response phenomena by exposure to radiofrequency radiation as either increased resistance to a subsequent dose of ionizing radiation or resistance to a bacterial infection has been reported recently. Interestingly, the potential beneficial effects of mobile phone radiofrequency radiation are not only limited to the induction of adaptive phenomena. It has previously been indicated that the visual reaction time of university students significantly decreased after a 10 min exposure to radiofrequency radiation emitted by a mobile phone. Furthermore, it has been revealed that occupational exposures to radar radiations decreased the reaction time in radar workers. Based on these findings, it can be hypothesized that in special circumstances, these exposures might lead to a better response of humans to different hazards. Other investigators have also provided evidence that confirms the induction of RF-induced cognitive benefits. Furthermore, some recent reports have indicated that RF radiation may play a role in protecting against cognitive impairment in Alzheimer’s disease. In this light, a challenging issue will arise if there are other RF-induced stimulating effects. It is also challenging to explore the potential applications of these effects. Further research may shed light on dark areas of the health effects of short and long-term human exposure to radiofrequency radiation. PMID:24843789
Mortazavi, Seyed Ali Reza; Tavakkoli-Golpayegani, Ali; Haghani, Masoud; Mortazavi, Seyed Mohammad Javad
2014-01-01
Although exposure to electromagnetic radiation in radiofrequency range has caused a great deal of concern globally, radiofrequency radiation has many critical applications in both telecommunication and non-communication fields. The induction of adaptive response phenomena by exposure to radiofrequency radiation as either increased resistance to a subsequent dose of ionizing radiation or resistance to a bacterial infection has been reported recently. Interestingly, the potential beneficial effects of mobile phone radiofrequency radiation are not only limited to the induction of adaptive phenomena. It has previously been indicated that the visual reaction time of university students significantly decreased after a 10 min exposure to radiofrequency radiation emitted by a mobile phone. Furthermore, it has been revealed that occupational exposures to radar radiations decreased the reaction time in radar workers. Based on these findings, it can be hypothesized that in special circumstances, these exposures might lead to a better response of humans to different hazards. Other investigators have also provided evidence that confirms the induction of RF-induced cognitive benefits. Furthermore, some recent reports have indicated that RF radiation may play a role in protecting against cognitive impairment in Alzheimer's disease. In this light, a challenging issue will arise if there are other RF-induced stimulating effects. It is also challenging to explore the potential applications of these effects. Further research may shed light on dark areas of the health effects of short and long-term human exposure to radiofrequency radiation.
Ruigrok, Hermanus J; Arnaud-Cormos, Delia; Hurtier, Annabelle; Poque, Emmanuelle; de Gannes, Florence Poulletier; Ruffié, Gilles; Bonnaudin, Fabrice; Lagroye, Isabelle; Sojic, Neso; Arbault, Stéphane; Lévêque, Philippe; Veyret, Bernard; Percherancier, Yann
2018-01-01
The existence of effects of radiofrequency field exposure at environmental levels on living tissues and organisms remains controversial, in particular regarding potential "nonthermal" effects produced in the absence of temperature elevation. Therefore, we investigated whether TRPV1, one of the most studied thermosensitive channels, can be activated by the heat produced by radiofrequency fields and by some specific nonthermal interaction with the fields. We have recently shown that TRPV1 activation can be assessed in real-time on live cells using the bioluminescence resonance energy transfer technique. Taking advantage of this innovative assay, we monitored TRPV1 thermal and chemical modes of activation under radiofrequency exposure at 1800 MHz using different signals (CW, GSM, UMTS, LTE, Wi-Fi and WiMAX) at specific absorption rates between 8 and 32 W/kg. We showed that, as expected, TRPV1 channels were activated by the heat produced by radiofrequency field exposure of transiently-transfected HEK293T cells, but found no evidence of TRPV1 activation in the absence of temperature elevation under radiofrequency field exposure. There was no evidence either that, at fixed temperature, radiofrequency exposure altered the maximal efficacy of the agonist Capsaicin to activate TRPV1.
Xue, Yumei; Zhan, Xianzhang; Wu, Shulin; Wang, Hongyue; Liu, Yang; Liao, Zili; Deng, Hai; Duan, Xuejing; Zeng, Shaoying; Liang, Dongpo; Elvan, Arif; Fang, Xianhong; Liao, Hongtao; Ramdat Misier, Anand R; Smit, Jaap Jan J; Metzner, Andreas; Heeger, Christian-Hendrik; Liu, Fangzhou; Wang, Feng; Zhang, Zhiwei; Kuck, Karl-Heinz; Yen Ho, Siew; Ouyang, Feifan
2017-06-01
Ablation of para-Hisian accessory pathway (AP) poses high risks of atrioventricular block. We developed a pacing technique to differentiate the near-field (NF) from far-field His activations to avoid the complication. Three-dimensional mapping of the right ventricle was performed in 15 mongrel dogs and 23 patients with para-Hisian AP. Using different pacing outputs, the NF- and far-field His activation was identified on the ventricular aspect. Radiofrequency application was delivered at the NF His site in 8 (group 1) and the far-field His site in 7 dogs (group 2), followed by pathologic examination after 14 days. NF His activation was captured with 5 mA/1 ms in 10 and 10 mA/1 ms in 5 dogs. In group 1, radiofrequency delivery resulted in complete atrioventricular block in 3, right bundle branch block with HV (His-to-ventricular) interval prolongation in 1, and only right bundle branch block in 2 dogs, whereas no changes occurred in group 2. Pathologic examination in group-1 dogs showed complete or partial necrosis of the His bundle in 4 and complete necrosis of the right bundle branch in 5 dogs. In group 2, partial necrosis in the right bundle branch was found only in 1 dog. Using this pacing technique, the APs were 5.7±1.2 mm away from the His bundle located superiorly in 20 or inferiorly in 3 patients. All APs were successfully eliminated with 1 to 3 radiofrequency applications. No complications and recurrence occurred during a follow-up of 11.8±1.4 months. Differentiating the NF His from far-field His activations led to a high ablation success without atrioventricular block in para-Hisian AP patients. © 2017 American Heart Association, Inc.
All-Dielectric Photonic-Assisted Radio Front-End Technology
NASA Astrophysics Data System (ADS)
Ayazi, Hossein Ali
The threats to civil society posed by high-power electromagnetic weapons are viewed as a grim but real possibility in the world after 11 September 2001. These weapons produce a power surge capable of destroying or damaging sensitive circuitry in electronic systems. Unfortunately, the trend towards circuits with smaller sizes and voltages renders modern electronics highly susceptible to such damage. Radiofrequency communication systems are particularly vulnerable, because the antenna provides a direct port of entry for electromagnetic radiation. In this work, we present a novel type of radiofrequency receiver front end featuring a complete absence of electronic circuitry and metal interconnects, the traditional 'soft spots' of a conventional radiofrequency receiver. The device exploits a dielectric resonator antenna to capture and deliver the radiofrequency signal onto a whispering-gallery mode electro-optic field sensor. The dielectric approach has an added benefit in that it reduces the physical size of the front end, an important benefit in mobile applications.
Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia
2014-01-01
Abstract Objective: An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Background data: Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. Methods: The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. Results: The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Conclusions: Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening. PMID:25244081
Nicoletti, Giovanni; Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia
2014-10-01
An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening.
de Melo, Roger Duarte; Acosta-Avalos, Daniel
2017-02-01
'Candidatus Magnetoglobus multicellularis' is the most studied multicellular magnetotactic prokaryote. It presents a light-dependent photokinesis: green light decreases the translation velocity whereas red light increases it, in comparison to blue and white light. The present article shows that radio-frequency electromagnetic fields cancel the light effect on photokinesis. The frequency to cancel the light effect corresponds to the Zeeman resonance frequency (DC magnetic field of 4 Oe and radio-frequency of 11.5 MHz), indicating the involvement of a radical pair mechanism. An analysis of the orientation angle relative to the magnetic field direction shows that radio-frequency electromagnetic fields disturb the swimming orientation when the microorganisms are illuminated with red light. The analysis also shows that at low magnetic fields (1.6 Oe) the swimming orientation angles are well scattered around the magnetic field direction, showing that magnetotaxis is not efficiently in the swimming orientation to the geomagnetic field. The results do not support cryptochrome as being the responsible chromophore for the radical pair mechanism and perhaps two different chromophores are necessary to explain the radio-frequency effects.
Optimal control design of turbo spin‐echo sequences with applications to parallel‐transmit systems
Hoogduin, Hans; Hajnal, Joseph V.; van den Berg, Cornelis A. T.; Luijten, Peter R.; Malik, Shaihan J.
2016-01-01
Purpose The design of turbo spin‐echo sequences is modeled as a dynamic optimization problem which includes the case of inhomogeneous transmit radiofrequency fields. This problem is efficiently solved by optimal control techniques making it possible to design patient‐specific sequences online. Theory and Methods The extended phase graph formalism is employed to model the signal evolution. The design problem is cast as an optimal control problem and an efficient numerical procedure for its solution is given. The numerical and experimental tests address standard multiecho sequences and pTx configurations. Results Standard, analytically derived flip angle trains are recovered by the numerical optimal control approach. New sequences are designed where constraints on radiofrequency total and peak power are included. In the case of parallel transmit application, the method is able to calculate the optimal echo train for two‐dimensional and three‐dimensional turbo spin echo sequences in the order of 10 s with a single central processing unit (CPU) implementation. The image contrast is maintained through the whole field of view despite inhomogeneities of the radiofrequency fields. Conclusion The optimal control design sheds new light on the sequence design process and makes it possible to design sequences in an online, patient‐specific fashion. Magn Reson Med 77:361–373, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine PMID:26800383
NASA Astrophysics Data System (ADS)
Liu, Xiaoming; Chen, Hui-jiuan; Chen, Xiaodong; Alfadhl, Yasir; Yu, Junsheng; Wen, Dongsheng
2015-03-01
In recent years, the application of nanomaterials to biological and biomedicine areas has attracted intensive interest. One of the hot topics is the nanomaterial mediated radiofrequency (RF) hyperthermia or ablation, i.e., using RF fields/waves to heat tumor tissues treated with nanomaterials to destroy cancerous cells while minimizing the side-heating effect. However, there are currently many contradictive results reported concerning the heating effect of nanomaterials under a RF field. This paper provided a comprehensive review to nanomaterial mediated RF ablation from both experimental and theoretical aspects. Three heating mechanisms were discussed, i.e., laser heating, magnetic field heating, and electric field heating in RF spectrum, with the focus on the last one. The results showed that while diluted pure metallic nanoparticles could be heated significantly by a laser through the surface plasmon resonance, they cannot be easily heated by a RF electric field. Further studies are proposed focusing on nanoparticle structure and morphology, electromagnetic frequency and localized heating effect to pave the way for future development.
Furth, H.P.; Chambers, E.S.
1962-03-01
BS>A method is given for ion cyclotron resonance heatthg of a magnetically confined plasma by an applied radio-frequency field. In accordance with the invention, the radiofrequency energy is transferred to the plasma without the usual attendent self-shielding effect of plasma polarlzatlon, whereby the energy transfer is accomplished with superior efficiency. More explicitly, the invention includes means for applying a radio-frequency electric field radially to an end of a plasma column confined in a magnetic mirror field configuration. The radio-frequency field propagates hydromagnetic waves axially through the column with the waves diminishing in an intermediate region of the column at ion cyclotron resonance with the fleld frequency. In such region the wave energy is converted by viscous damping to rotational energy of the plasma ions. (AEC)
Excessive radiofrequency application: effects on capsular tissue in an animal model.
Wolf, Brian R; Heiner, Anneliese D; Albright, John P; Nepola, James V
2005-01-01
Capsular attenuation has been seen after thermal capsulorrhaphy surgery. The purpose of this study was to evaluate the mechanical, histologic, and morphologic effects on capsular tissue after cumulative applications of radiofrequency energy. Ovine patellofemoral capsular tissue was treated with 1, 2, 4, or 8 applications of bipolar radiofrequency energy and then analyzed. No acute capsular ablation or destruction was seen grossly, even in the 8-application group. No definitive visual clues that excessive radiofrequency energy had been applied were seen. There was significant shrinkage and loss of tensile stiffness for all thermal application groups. Given the small sample sizes, post-application failure load, percent relaxation, and stiffness were not observed to be significantly different among the groups. Cumulative applications produced minimal further tissue shrinkage but were accompanied by larger, though not statistically significant, mechanical property losses and increased depth of tissue penetration. These findings suggest that there is no benefit to repeated applications of radiofrequency energy to capsular tissue.
NASA Astrophysics Data System (ADS)
Vedruccio, Clarbruno; Ricci Vedruccio, Carla
2011-12-01
A new paper by Pokorny, Vedruccio, Cifra, Kucera, titled Cancer physics: Diagnostics based on damped cellular elasto-electrical vibrations in microtubules, recently available on Eur. Biophys. J., discloses the mechanism of active grown cancer tissues interaction with a Non- Linear Resonance Interaction (NLRI) Bioscanner Trimprob diagnostic device that is certified and ready to be used to investigate suspected cases of disease and cancer. This technology spreads early capabilities of cancer detection by means of low level radiofrequency oscillations in UHF band. The system is based on an unique and extremely innovative non- linear radiofrequency oscillator working on 462-465 MHz plus the harmonics. The diseased tissues suspected of cancer, are irradiated by means of a handy probe near field emission, while a spectrum analyzer placed in the far field detects by means of a small antenna, the oscillator interaction within the tissues. The Bioscanner is characterized by a high dynamic range, in the order of 30 or more decibel, and is useful for detection of small cancer agglomerates, if used by a well trained operator. At the resonance, the free running oscillator locks-in on the specific interaction frequency, in a sharp frequency window centered on 462 MHz; the resulting effect is evidenced by a deep decrease of the 462 MHz spectral line propagation in the far field around the oscillator probe. The NLRI provides a selective characterization, like a sort of a electronic biopsy response of biologic tissues in support of modern imaging diagnostics. Further to existing literature describing methods for cancer detections by means of electromagnetic fields this paper shows this innovative in vivo medical diagnostic equipment and some clinical applications.
Abraham, Roney; Ibrahim, Tamer S
2007-02-01
In this article, a radiofrequency (RF) excitation scheme for 7-Tesla (T) whole-body applications is derived and analyzed using the finite difference time domain (FDTD) method. Important features of the proposed excitation scheme and coil (a potential 7T whole-body transverse electromagnetic [TEM] resonator design), from both operational and electromagnetic perspectives, are discussed. The choice of the coil's operational mode is unconventional; instead of the typical "homogenous mode," we use a mode that provides a null field in the center of the coil at low-field applications. Using a 3D FDTD implementation of Maxwell's equations, we demonstrate that the whole-body 7T TEM coil (tuned to the aforementioned unconventional mode and excited in an optimized near-field, phased-array fashion) can potentially provide 1) homogenous whole-slice (demonstrated in three axial, sagittal, and coronal slices) and 2) 3D localized (demonstrated in the heart) excitations. As RF power was not considered as a part of the optimization in several cases, the significant improvements achieved by whole-slice RF excitation came at the cost of considerable increases in RF power requirements. Copyright (c) 2007 Wiley-Liss, Inc.
Cao, Yi; Tong, Jian
2014-04-22
During the last few years, our research group has been investigating the phenomenon of adaptive response in animals exposed to non-ionizing radiofrequency fields. The results from several separate studies indicated a significant increase in survival, decreases in genetic damage as well as oxidative damage and, alterations in several cellular processes in mice pre-exposed to radiofrequency fields and subsequently subjected to sub-lethal or lethal doses of γ-radiation or injected with bleomycin, a radiomimetic chemical mutagen. These observations indicated the induction of adaptive response providing the animals the ability to resist subsequent damage. Similar studies conducted by independent researchers in mice and rats have supported our observation on increased survival. In this paper, we have presented a brief review of all of our own and other independent investigations on radiofrequency fields-induced adaptive response and some underlying mechanisms discussed.
Cao, Yi; Tong, Jian
2014-01-01
During the last few years, our research group has been investigating the phenomenon of adaptive response in animals exposed to non-ionizing radiofrequency fields. The results from several separate studies indicated a significant increase in survival, decreases in genetic damage as well as oxidative damage and, alterations in several cellular processes in mice pre-exposed to radiofrequency fields and subsequently subjected to sub-lethal or lethal doses of γ-radiation or injected with bleomycin, a radiomimetic chemical mutagen. These observations indicated the induction of adaptive response providing the animals the ability to resist subsequent damage. Similar studies conducted by independent researchers in mice and rats have supported our observation on increased survival. In this paper, we have presented a brief review of all of our own and other independent investigations on radiofrequency fields-induced adaptive response and some underlying mechanisms discussed. PMID:24758897
78 FR 33654 - Reassessment of Exposure to Radiofrequency Electromagnetic Fields Limits and Policies
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-04
... Docket Nos. 03-137 and 13-84; FCC 13-39] Reassessment of Exposure to Radiofrequency Electromagnetic... electromagnetic fields. The Commission's further proposals reflect an effort to provide more efficient, practical... RF electromagnetic fields. The Commission underscores that in conducting this review it will work...
47 CFR 1.1306 - Actions which are categorically excluded from environmental processing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... radiofrequency radiation in excess of the applicable safety standards specified in § 1.1307(b). Note 1: The... human exposure to radiofrequency radiation in excess of the applicable health and safety guidelines... provisions of § 1.1307(b) and the additional radiofrequency radiation from the antenna(s) on the new tower or...
Bidinosti, C P; Kravchuk, I S; Hayden, M E
2005-11-01
We provide an exact expression for the magnetic field produced by cylindrical saddle-shaped coils and their ideal shield currents in the low-frequency limit. The stream function associated with the shield surface current is also determined. The results of the analysis are useful for the design of actively shielded radio-frequency (RF) coils. Examples pertinent to very low field nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) are presented and discussed.
NASA Astrophysics Data System (ADS)
Posen, S.; Liepe, M.; Hall, D. L.
2015-02-01
Many future particle accelerators require hundreds of superconducting radiofrequency (SRF) cavities operating with high duty factor. The large dynamic heat load of the cavities causes the cryogenic plant to make up a significant part of the overall cost of the facility. This contribution can be reduced by replacing standard niobium cavities with ones coated with a low-dissipation superconductor such as Nb3Sn. In this paper, we present results for single cell cavities coated with Nb3Sn at Cornell. Five coatings were carried out, showing that at 4.2 K, high Q0 out to medium fields was reproducible, resulting in an average quench field of 14 MV/m and an average 4.2 K Q0 at quench of 8 × 109. In each case, the peak surface magnetic field at quench was well above Hc1, showing that it is not a limiting field in these cavities. The coating with the best performance had a quench field of 17 MV/m, exceeding gradient requirements for state-of-the-art high duty factor SRF accelerators. It is also shown that—taking into account the thermodynamic efficiency of the cryogenic plant—the 4.2 K Q0 values obtained meet the AC power consumption requirements of state-of-the-art high duty factor accelerators, making this a proof-of-principle demonstration for Nb3Sn cavities in future applications.
Ablation effects of noninvasive radiofrequency field-induced hyperthermia on liver cancer cells.
Chen, Kaiyun; Zhu, Shuguang; Xiang, Guoan; Duan, Xiaopeng; He, Jiwen; Chen, Guihua
2016-05-01
To have in-depth analysis of clinical ablation effect of noninvasive radiofrequency field-induced hyperthermia on liver cancer cells, this paper collected liver cancer patients' treatment information from 10 hospitals during January 2010 and December 2011, from which 1050 cases of patients were randomly selected as study object of observation group who underwent noninvasive radiofrequency field-induced hyperthermia treatment; in addition, 500 cases of liver cancer patients were randomly selected as study object of control group who underwent clinical surgical treatment. After treatment was completed, three years of return visit were done, survival rates of the two groups of patients after 1 year, 2 years, and 3 years were compared, and clinical effects of radiofrequency ablation of liver cancer were evaluated. Zoom results show that the two groups are similar in terms of survival rate, and the difference is without statistical significance. 125 patients in observation group had varying degrees of adverse reactions, while 253 patients in control group had adverse reactions. There was difference between groups P < 0.05, with significant statistical significance. It can be concluded that radiofrequency ablation of liver cancer is more secure. Therefore, the results of this study fully demonstrate that liver cancer treatment with noninvasive radiofrequency field-induced hyperthermia is with safety effect and satisfactory survival rate, thus with relatively high clinical value in clinical practice.
47 CFR 1.1310 - Radiofrequency radiation exposure limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Criteria for Radiofrequency Electromagnetic Fields,” NCRP Report No. 86, Sections 17.4.1, 17.4.1.1, 17.4.2... Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz,” ANSI...
47 CFR 2.1093 - Radiofrequency radiation exposure evaluation: portable devices.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Electromagnetic Fields, 3 kHz to 300 GHz,” ANSI/IEEE C95.1-1992, Copyright 1992 by the Institute of Electrical and... Exposure Criteria for Radiofrequency Electromagnetic Fields,” NCRP Report No. 86, Section 17.4.5. Copyright...
47 CFR 1.1310 - Radiofrequency radiation exposure limits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Criteria for Radiofrequency Electromagnetic Fields,” NCRP Report No. 86, Sections 17.4.1, 17.4.1.1, 17.4.2... Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz,” ANSI...
Self-shielded electron linear accelerators designed for radiation technologies
NASA Astrophysics Data System (ADS)
Belugin, V. M.; Rozanov, N. E.; Pirozhenko, V. M.
2009-09-01
This paper describes self-shielded high-intensity electron linear accelerators designed for radiation technologies. The specific property of the accelerators is that they do not apply an external magnetic field; acceleration and focusing of electron beams are performed by radio-frequency fields in the accelerating structures. The main characteristics of the accelerators are high current and beam power, but also reliable operation and a long service life. To obtain these characteristics, a number of problems have been solved, including a particular optimization of the accelerator components and the application of a variety of specific means. The paper describes features of the electron beam dynamics, accelerating structure, and radio-frequency power supply. Several compact self-shielded accelerators for radiation sterilization and x-ray cargo inspection have been created. The introduced methods made it possible to obtain a high intensity of the electron beam and good performance of the accelerators.
NASA Astrophysics Data System (ADS)
Yeung, Sai Ho; Pradhan, Raunaq; Feng, Xiaohua; Zheng, Yuanjin
2015-09-01
Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF) stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence enhancing the current flowing through the nerve, thus enabling stimulation. In this paper, the developed magnetic resonant coupling (MRC) stimulation, magnetic stimulation (MS) and transcutaneous electrical nerve stimulation (TENS) are compared. The differences between the MRC RF stimulation and other techniques are presented in terms of the operating mechanism, ex-vivo tissue voltage measurement and electromagnetic simulation analysis. The ev-vivo tissue voltage measurement experiment is performed on the compared devices based on measuring the voltage induced by electromagnetic induction at the tissue. The focusing effect, E field and voltage induced across the tissue, and the attenuation due to the increase of separation between the coil and the target are analyzed. The electromagnetic stimulation will also be performed to obtain the electric field and magnetic field distribution around the biological medium. The electric field intensity is proportional to the induced current and the magnetic field is corresponding to the electromagnetic induction across the biological medium. The comparison between the MRC RF stimulator and the MS and TENS devices revealed that the MRC RF stimulator has several advantages over the others for the applications of inducing current in the biological medium for stimulation purposes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeung, Sai Ho; Pradhan, Raunaq; Feng, Xiaohua
Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF) stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence enhancing the current flowing through the nerve, thus enabling stimulation. In this paper, the developed magnetic resonant coupling (MRC) stimulation, magnetic stimulation (MS) and transcutaneous electrical nerve stimulation (TENS) are compared. The differences between the MRC RF stimulation and other techniques are presented in terms of the operating mechanism, ex-vivo tissue voltage measurement and electromagnetic simulation analysis. The ev-vivo tissuemore » voltage measurement experiment is performed on the compared devices based on measuring the voltage induced by electromagnetic induction at the tissue. The focusing effect, E field and voltage induced across the tissue, and the attenuation due to the increase of separation between the coil and the target are analyzed. The electromagnetic stimulation will also be performed to obtain the electric field and magnetic field distribution around the biological medium. The electric field intensity is proportional to the induced current and the magnetic field is corresponding to the electromagnetic induction across the biological medium. The comparison between the MRC RF stimulator and the MS and TENS devices revealed that the MRC RF stimulator has several advantages over the others for the applications of inducing current in the biological medium for stimulation purposes.« less
Radiofrequency electromagnetic fields; male infertility and sex ratio of offspring.
Baste, Valborg; Riise, Trond; Moen, Bente E
2008-01-01
Concern is growing about exposure to electromagnetic fields and male reproductive health. The authors performed a cross-sectional study among military men employed in the Royal Norwegian Navy, including information about work close to equipment emitting radiofrequency electromagnetic fields, one-year infertility, children and sex of the offspring. Among 10,497 respondents, 22% had worked close to high-frequency aerials to a "high" or "very high" degree. Infertility increased significantly along with increasing self-reported exposure to radiofrequency electromagnetic fields. In a logistic regression, odds ratio (OR) for infertility among those who had worked closer than 10 m from high-frequency aerials to a "very high" degree relative to those who reported no work near high-frequency aerials was 1.86 (95% confidence interval (CI): 1.46-2.37), adjusted for age, smoking habits, alcohol consumption and exposure to organic solvents, welding and lead. Similar adjusted OR for those exposed to a "high", "some" and "low" degree were 1.93 (95% CI: 1.55-2.40), 1.52 (95% CI: 1.25-1.84), and 1.39 (95% CI: 1.15-1.68), respectively. In all age groups there were significant linear trends with higher prevalence of involuntary childlessness with higher self-reported exposure to radiofrequency fields. However, the degree of exposure to radiofrequency radiation and the number of children were not associated. For self-reported exposure both to high-frequency aerials and communication equipment there were significant linear trends with lower ratio of boys to girls at birth when the father reported a higher degree of radiofrequency electromagnetic exposure.
Mortazavi, S A R; Mortazavi, Ghazal; Mortazavi, S M J
2017-12-31
This correspondence refers to the Science of the Total Environment article by Gonzalez-Rubio et al. entitled "Radiofrequency electromagnetic fields and some cancers of unknown etiology: An ecological study". Authors of this paper have presented the findings of their preliminary epidemiological study which combined epidemiology, statistics and geographical information systems (GIS). Gonzalez-Rubio et al. have analyzed the possible link between exposure to Radiofrequency Electromagnetic Fields (RF-EMF) in the city of Albacete, Spain and the incidence of cancers such as lymphomas, and brain tumors. The shortcomings of this study are discussed. Copyright © 2017 Elsevier B.V. All rights reserved.
Is fertility reduced among men exposed to radiofrequency fields in the Norwegian Navy?
Møllerløkken, Ole J; Moen, Bente E
2008-07-01
The effects of radiofrequency fields on human health are not well understood, and public concern about negative health effects has been rising. The aim of this study was to examine the relationship between workers exposed to electromagnetic fields and their reproductive health. We obtained data using a questionnaire in a cross-sectional study of naval military men, response rate 63% (n = 1487). We asked the respondents about exposure, lifestyle, reproductive health, previous diseases, work and education. An expert group categorized the work categories related to electromagnetic field exposure. We categorized the work categories "tele/communication," "electronics" and "radar/sonar" as being exposed to electromagnetic fields. Logistic regression adjusted for age, ever smoked, military education, and physical exercise at work showed increased risk of infertility among tele/communication odds ratio (OR = 1.72, 95% confidence interval 1.04-2.85), and radar/sonar odds ratio (OR = 2.28, 95% confidence interval 1.27-4.09). The electronics group had no increased risk. This study shows a possible relationship between exposure to radiofrequency fields during work with radiofrequency equipment and radar and reduced fertility. However, the results must be interpreted with caution.
NASA Astrophysics Data System (ADS)
Mansouri, S.; Coskun, B.; El Mir, L.; Al-Sehemi, Abdullah G.; Al-Ghamdi, Ahmed; Yakuphanoglu, F.
2018-04-01
Graphene is a sheet-structured material that lacks a forbidden band, being a good candidate for use in radiofrequency applications. We have elaborated graphene-oxide-doped poly(3-hexylthiophene) nanocomposite to increase the interlayer distance and thereby open a large bandgap for use in the field of logic circuits. Graphene oxide/poly(3-hexylthiophene) (GO/P3HT) nanocomposite thin-film transistors (TFTs) were fabricated on silicon oxide substrate by spin coating method. The current-voltage ( I- V) characteristics of TFTs with various P3HT compositions were studied in the dark and under light illumination. The photocurrent, charge carrier mobility, subthreshold voltage, density of interface states, density of occupied states, and I ON/ I OFF ratio of the devices strongly depended on the P3HT weight ratio in the composite. The effects of white-light illumination on the electrical parameters of the transistors were investigated. The results indicated that GO/P3HT nanocomposite thin-film transistors have high potential for use in radiofrequency applications, and their feasibility for use in digital applications has been demonstrated.
47 CFR 1.1310 - Radiofrequency radiation exposure limits.
Code of Federal Regulations, 2013 CFR
2013-10-01
... FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields,” and in supplements to... electromagnetic energy. The SAR limits to be used for evaluation are based generally on criteria published by the... with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz,” ANSI/IEEE...
47 CFR 1.1310 - Radiofrequency radiation exposure limits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields,” and in supplements to... electromagnetic energy. The SAR limits to be used for evaluation are based generally on criteria published by the... with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz,” ANSI/IEEE...
Posen, S.; Liepe, M.; Hall, D. L.
2015-02-23
Many future particle accelerators require hundreds of superconducting radiofrequency (SRF) cavities operating with high duty factor. The large dynamic heat load of the cavities causes the cryogenic plant to make up a significant part of the overall cost of the facility. Our contribution can be reduced by replacing standard niobium cavities with ones coated with a low-dissipation superconductor such as Nb 3Sn. Here, we present results for single cell cavities coated with Nb 3Sn at Cornell. Five coatings were carried out, showing that at 4.2 K, high Q 0 out to medium fields was reproducible, resulting in an average quenchmore » field of 14 MV/m and an average 4.2 K Q 0 at quench of 8 x 10 9 . In each case, the peak surface magnetic field at quench was well above H c1, showing that it is not a limiting field in these cavities. Furthermore, the coating with the best performance had a quench field of 17 MV/m, exceeding gradient requirements for state-of-the-art high duty factor SRF accelerators. It is also shown that—taking into account the thermodynamic efficiency of the cryogenic plant—the 4.2 K Q 0 values obtained meet the AC power consumption requirements of state-of-the-art high duty factor accelerators, making this a proof-of-principle demonstration for Nb 3Sn cavities in future applications.« less
Drone based measurement system for radiofrequency exposure assessment.
Joseph, Wout; Aerts, Sam; Vandenbossche, Matthias; Thielens, Arno; Martens, Luc
2016-03-10
For the first time, a method to assess radiofrequency (RF) electromagnetic field (EMF) exposure of the general public in real environments with a true free-space antenna system is presented. Using lightweight electronics and multiple antennas placed on a drone, it is possible to perform exposure measurements. This technique will enable researchers to measure three-dimensional RF-EMF exposure patterns accurately in the future and at locations currently difficult to access. A measurement procedure and appropriate measurement settings have been developed. As an application, outdoor measurements are performed as a function of height up to 60 m for Global System for Mobile Communications (GSM) 900 MHz base station exposure. Bioelectromagnetics. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Sadick, Neil; Sorhaindo, Lian
2005-05-01
Radiofrequency (RF) and combined RF light source technologies have established themselves as safe and effective treatment modalities for several dermatologic procedures, including skin tightening, hair and leg vein removal, acne scarring, skin rejuvenation, and wrinkle reduction. This article reviews the technology, clinical applications, and recent advances of RF and combined RF light/laser source technologies in aesthetic medicine.
ERIC Educational Resources Information Center
Sage, Cindy; Burgio, Ernesto
2018-01-01
Mobile phones and other wireless devices that produce electromagnetic fields (EMF) and pulsed radiofrequency radiation (RFR) are widely documented to cause potentially harmful health impacts that can be detrimental to young people. New epigenetic studies are profiled in this review to account for some neurodevelopmental and neurobehavioral changes…
47 CFR 2.1093 - Radiofrequency radiation exposure evaluation: portable devices.
Code of Federal Regulations, 2012 CFR
2012-10-01
... for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to... Exposure Criteria for Radiofrequency Electromagnetic Fields,” NCRP Report No. 86, Section 17.4.5. Copyright... Electromagnetic Fields—RF and Microwave,” IEEE C95.3-1991. (4) For purposes of analyzing portable transmitting...
Yamaguchi, Naohito
2013-01-01
The International Agency for Research on Cancer of World Health Organization announced in May 2011 the results of evaluation of carcinogenicity of radio-frequency electromagnetic field. In the overall evaluation, the radio-frequency electromagnetic field was classified as "possibly carcinogenic to humans", on the basis of the fact that the evidence provided by epidemiological studies and animal bioassays was limited. Regarding epidemiology, the results of the Interphone Study, an international collaborative case-control study, were of special importance, together with the results of a prospective cohort study in Denmark, case-control studies in several countries, and a case-case study in Japan. The evidence obtained was considered limited, because the increased risk observed in some studies was possibly spurious, caused by selection bias or recall bias as well as residual effects of confounding factors. Further research studies, such as large-scale multinational epidemiological studies, are crucially needed to establish a sound evidence base from which a more conclusive judgment can be made for the carcinogenicity of the radio-frequency electromagnetic field.
Radiofrequency heating pathways for gold nanoparticles.
Collins, C B; McCoy, R S; Ackerson, B J; Collins, G J; Ackerson, C J
2014-08-07
This feature article reviews the thermal dissipation of nanoscopic gold under radiofrequency (RF) irradiation. It also presents previously unpublished data addressing obscure aspects of this phenomenon. While applications in biology motivated initial investigation of RF heating of gold nanoparticles, recent controversy concerning whether thermal effects can be attributed to nanoscopic gold highlight the need to understand the involved mechanism or mechanisms of heating. Both the nature of the particle and the nature of the RF field influence heating. Aspects of nanoparticle chemistry which may affect thermal dissipation include the hydrodynamic diameter of the particle, the oxidation state and related magnetism of the core, and the chemical nature of the ligand shell. Aspects of RF which may affect thermal dissipation include power, frequency and antenna designs that emphasize relative strength of magnetic or electric fields. These nanoparticle and RF properties are analysed in the context of three heating mechanisms proposed to explain gold nanoparticle heating in an RF field. This article also makes a critical analysis of the existing literature in the context of the nanoparticle preparations, RF structure, and suggested mechanisms in previously reported experiments.
Radiofrequency Heating Pathways for Gold Nanoparticles
Collins, C. B.; McCoy, R. S.; Ackerson, B. J.; Collins, G. J.
2015-01-01
This feature article reviews the thermal dissipation of nanoscopic gold under radiofrequency (RF) irradiation. It also presents previously unpublished data addressing obscure aspects of this phenomenon. While applications in biology motivated initial investigation of RF heating of gold nanoparticles, recent controversy concerning whether thermal effects can be attributed to nanoscopic gold highlight the need to understand the involved mechanism or mechanisms of heating. Both the nature of the particle and the nature of the RF field influence heating. Aspects of nanoparticle chemistry and physics, including the hydrodynamic diameter of the particle, the oxidation state and related magnetism of the core, and the chemical nature of the ligand shell may all strongly influence to what extent a nanoparticle heats in an RF field. Aspects of RF include: power, frequency and antenna designs that emphasize relative strength of magnetic or electric fields, and also influence the extent to which a gold nanoparticle heats in RF. These nanoparticle and RF properties are analysed in the context of three heating mechanisms proposed to explain gold nanoparticle heating in an RF field. This article also makes a critical analysis of the existing literature in the context of the nanoparticle preparations, RF structure, and suggested mechanisms in previously reported experiments. PMID:24962620
Superconducting surface impedance under radiofrequency field
Xiao, Binping P.; Reece, Charles E.; Kelley, Michael J.
2013-04-26
Based on BCS theory with moving Cooper pairs, the electron states distribution at 0K and the probability of electron occupation with finite temperature have been derived and applied to anomalous skin effect theory to obtain the surface impedance of a superconductor under radiofrequency (RF) field. We present the numerical results for Nb and compare these with representative RF field-dependent effective surface resistance measurements from a 1.5 GHz resonant structure.
Posen, S.; Checchin, M.; Crawford, A. C.; ...
2016-06-03
Even when cooled through its transition temperature in the presence of an external magnetic field, a superconductor can expel nearly all external magnetic flux. This Letter presents an experimental study to identify the parameters that most strongly influence flux trapping in high purity niobium during cooldown. This is critical to the operation of superconducting radiofrequency cavities, in which trapped flux degrades the quality factor and therefore cryogenic efficiency. Flux expulsion was measured on a large survey of 1.3 GHz cavities prepared in various ways. It is shown that both spatial thermal gradient and high temperature treatment are critical to expellingmore » external magnetic fields, while surface treatment has minimal effect. For the first time, it is shown that a cavity can be converted from poor expulsion behavior to strong expulsion behavior after furnace treatment, resulting in a substantial improvement in quality factor. In conclusion, future plans are described to build on this result in order to optimize treatment for future cavities.« less
47 CFR 1.1310 - Radiofrequency radiation exposure limits.
Code of Federal Regulations, 2012 CFR
2012-10-01
... “Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields,” NCRP Report No. 86... of “IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic...
21 CFR 882.4400 - Radiofrequency lesion generator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... lesions in the nervous system or other tissue by the direct application of radiofrequency currents to... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiofrequency lesion generator. 882.4400 Section 882.4400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...
21 CFR 882.4400 - Radiofrequency lesion generator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... lesions in the nervous system or other tissue by the direct application of radiofrequency currents to... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiofrequency lesion generator. 882.4400 Section 882.4400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...
21 CFR 882.4400 - Radiofrequency lesion generator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... lesions in the nervous system or other tissue by the direct application of radiofrequency currents to... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiofrequency lesion generator. 882.4400 Section 882.4400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...
Synthetic clock states generated in a Bose-Einstein condensate via continuous dynamical decoupling
NASA Astrophysics Data System (ADS)
Lundblad, Nathan; Trypogeorgos, Dimitrios; Valdes-Curiel, Ana; Marshall, Erin; Spielman, Ian
2017-04-01
Radiofrequency- or microwave-dressed states have been used in NV center and ion-trap experiments to extend coherence times, shielding qubits from magnetic field noise through a process known as continuous dynamical decoupling. Such field-insensitive dressed states, as applied in the context of ultracold neutral atoms, have applications related to the creation of novel phases of spin-orbit-coupled quantum matter. We present observations of such a protected dressed-state system in a Bose-Einstein condensate, including measurements of the dependence of the protection on rf coupling strength, and estimates of residual field sensitivities.
Subramanian, Sankaran; Koscielniak, Janusz W.; Devasahayam, Nallathamby; Pursley, Randall H.; Pohida, Thomas J.; Krishna, Murali C.
2007-01-01
Rapid field scan on the order of T/s using high frequency sinusoidal or triangular sweep fields superimposed on the main Zeeman field, was used for direct detection of signals without low-frequency field modulation. Simultaneous application of space-encoding rotating field gradients have been employed to perform fast CW EPR imaging using direct detection that could, in principle, approach the speed of pulsed FT EPR imaging. The method takes advantage of the well-known rapid-scan strategy in CW NMR and EPR that allows arbitrarily fast field sweep and the simultaneous application of spinning gradients that allows fast spatial encoding. This leads to fast functional EPR imaging and, depending on the spin concentration, spectrometer sensitivity and detection band width, can provide improved temporal resolution that is important to interrogate dynamics of spin perfusion, pharmacokinetics, spectral spatial imaging, dynamic oxymetry, etc. PMID:17350865
[GERD: endoscopic antireflux therapies].
Caca, K
2006-08-02
A couple of minimally-invasive, endoscopic antireflux procedures have been developed during the last years. Beside endoscopic suturing these included injection/implantation technique of biopolymers and application of radiofrequency. Radiofrequency (Stretta) has proved only a very modest effect, while implantation techniques have been abandoned due to lack of long-term efficacy (Gatekeeper) or serious side effects (Enteryx). While first generation endoluminal suturing techniques (EndoCinch, ESD) demonstrated a proof of principle their lack of durability, due to suture loss, led to the development of a potentially durable transmural plication technique (Plicator). In a prospective-randomized, sham-controlled trial the Plicator procedure proved superiority concerning reflux symptoms, medication use and esophageal acid exposure (24-h-pH-metry). While long-term data have to be awaited to draw final conclusions, technical improvements will drive innovation in this field.
OCCUPATIONAL EXPOSURE OF NMR SPECTROMETRISTS TO STATIC AND RADIOFREQUENCY FIELDS.
Berlana, Tania; Úbeda, Alejandro
2017-12-01
Occupational exposure to static and radiofrequency fields emitted by nuclear magnetic resonance spectrometers was assessed through systematic field metering during operation of 19 devices in nine research centers. Whereas no measurable levels of radiofrequency radiation were registered outside the spectrometers, significant exposure to static field was detected, with maximum values recorded at the user's hand (B = 683.00 mT) and head-thorax (B = 135.70 mT) during spectrometer manipulation. All values were well below the exposure limits set by the European standard for workers protection against the effects of acute field exposure only. As for potential effects of chronic exposure, waiting for more complete knowledge, adoption of technical and operational strategies for exposure minimizing is advisable. In this respect, the data revealed that compared with standard magnetic shielding, ultrashield technology allows a 20-65-fold reduction of the field strength received by the operator. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Gryz, Krzysztof; Zradziński, Patryk; Karpowicz, Jolanta
2015-01-01
The use of radiofrequency (98-2450 MHz range) personal exposimeters to measure the electric field (E-field) in far-field exposure conditions was modelled numerically using human body model Gustav and finite integration technique software. Calculations with 256 models of exposure scenarios show that the human body has a significant influence on the results of measurements using a single body-worn exposimeter in various locations near the body ((from -96 to +133)%, measurement errors with respect to the unperturbed E-field value). When an exposure assessment involves the exposure limitations provided for the strength of an unperturbed E-field. To improve the application of exposimeters in compliance tests, such discrepancies in the results of measurements by a body-worn exposimeter may be compensated by using of a correction factor applied to the measurement results or alternatively to the exposure limit values. The location of a single exposimeter on the waist to the back side of the human body or on the front of the chest reduces the range of exposure assessments uncertainty (covering various exposure conditions). However, still the uncertainty of exposure assessments using a single exposimeter remains significantly higher than the assessment of the unperturbed E-field using spot measurements.
Zradziński, Patryk
2015-01-01
The use of radiofrequency (98–2450 MHz range) personal exposimeters to measure the electric field (E-field) in far-field exposure conditions was modelled numerically using human body model Gustav and finite integration technique software. Calculations with 256 models of exposure scenarios show that the human body has a significant influence on the results of measurements using a single body-worn exposimeter in various locations near the body ((from −96 to +133)%, measurement errors with respect to the unperturbed E-field value). When an exposure assessment involves the exposure limitations provided for the strength of an unperturbed E-field. To improve the application of exposimeters in compliance tests, such discrepancies in the results of measurements by a body-worn exposimeter may be compensated by using of a correction factor applied to the measurement results or alternatively to the exposure limit values. The location of a single exposimeter on the waist to the back side of the human body or on the front of the chest reduces the range of exposure assessments uncertainty (covering various exposure conditions). However, still the uncertainty of exposure assessments using a single exposimeter remains significantly higher than the assessment of the unperturbed E-field using spot measurements. PMID:25879021
47 CFR 1.9080 - Private commons.
Code of Federal Regulations, 2010 CFR
2010-10-01
... radiofrequency radiation) and maintaining the ability to ensure such compliance; and, (3) Retains direct... applicable technical and service rules, including requirements relating to radiofrequency radiation and...
Review of Electronics Based on Single-Walled Carbon Nanotubes.
Cao, Yu; Cong, Sen; Cao, Xuan; Wu, Fanqi; Liu, Qingzhou; Amer, Moh R; Zhou, Chongwu
2017-08-14
Single-walled carbon nanotubes (SWNTs) are extremely promising materials for building next-generation electronics due to their unique physical and electronic properties. In this article, we will review the research efforts and achievements of SWNTs in three electronic fields, namely analog radio-frequency electronics, digital electronics, and macroelectronics. In each SWNT-based electronic field, we will present the major challenges, the evolutions of the methods to overcome these challenges, and the state-of-the-art of the achievements. At last, we will discuss future directions which could lead to the broad applications of SWNTs. We hope this review could inspire more research on SWNT-based electronics, and accelerate the applications of SWNTs.
Effects of radiation from a radiofrequency identification (RFID) microchip on human cancer cells.
Lai, Henry C; Chan, Ho Wing; Singh, Narendra P
2016-01-01
Radiofrequency identification (RFID) microchips are used to remotely identify objects, e.g. an animal in which a chip is implanted. A passive RFID microchip absorbs energy from an external source and emits a radiofrequency identification signal which is then decoded by a detector. In the present study, we investigated the effect of the radiofrequency energy emitted by a RFID microchip on human cancer cells. Molt-4 leukemia, BT474 breast cancer, and HepG2 hepatic cancer cells were exposed in vitro to RFID microchip-emitted radiofrequency field for 1 h. Cells were counted before and after exposure. Effects of pretreatment with the spin-trap compound N-tert-butyl-alpha-phenylnitrone or the iron-chelator deferoxamine were also investigated. Results We found that the energy effectively killed/retarded the growth of the three different types of cancer cells, and the effect was blocked by the spin-trap compound or the iron-chelator, whereas an inactive microchip and energy from the external source had no significant effect on the cells. Conclusions Data of the present study suggest that radiofrequency field from the microchip affects cancer cells via the Fenton Reaction. Implantation of RFID microchips in tumors may provide a new method for cancer treatment.
1981-09-01
setting and application of RFR safety standards, assessment of RFR levels in the military workplaces, RFR instrumentation and dosimetry , the medical...RADIOFREQUENCY BURN HAZARDS IN THE MF/HF BAND ................ ... 76 S. J. Rogers (U.K.) 3. RADIOFREQUENCY RADIATION INSTRUMENTATION AND DOSIMETRY ...97 B. Audone, L. Bolla, and G. Gerbi (Italy) RADIOFREQUENCY RADIATION DOSIMETRY : A REVIEW OF THEORETICAL METHODS AND EXPERIMENTAL RESULTS
Improved Image-Guided Laparoscopic Prostatectomy
2012-08-01
prevalent technique used in widening the field of view (FOV) of medical ultrasound images. Also referred to as stitching or panorama , the ultra- sound mosaic...tissue which can add valu- able features to the B-mode panorama . Many clinical applications deal with large cancerous lesions which expand beyond the...1999) 203–233 2. Varghese, T., Zagzebski, J., Lee Jr., F.: Elastographic imaging of thermal lesions in the liver in vivo following radiofrequency
Radio-frequency ring applicator: energy distributions measured in the CDRH phantom.
van Rhoon, G C; Raskmark, P; Hornsleth, S N; van den Berg, P M
1994-11-01
SAR distributions were measured in the CDRH phantom, a 1 cm fat-equivalent shell filled with an abdomen-equivalent liquid (sigma = 0.4-1.0 S m-1; dimensions 22 x 32 x 57 cm) to demonstrate the feasibility of the ring applicator to obtain deep heating. The ring electrodes were fixed in a PVC tube; diameter 48 cm, ring width 20 cm and gap width between both rings 31.6 cm. Radio-frequency energy was fed to the electrodes at eight points. The medium between the electrodes and the phantom was deionised water. The SAR distribution in the liquid tissue volume was obtained by a scanning E-field probe measuring the E-field in all three directions. With equal amplitude and phase applied to all feeding points, a uniform SAR distribution was measured in the central cross-section at 30 MHz. With RF energy supplied to only four adjacent feeding points (others were connected to a 50 omega load), the feasibility to perform amplitude steering was demonstrated; SAR values above 50% of the maximum SAR were measured in one quadrant only. SAR distributions obtained at 70 MHz showed an improved focusing ability; a maximum at the centre exists for an electric conductivity of the abdomen-equivalent tissue of 0.6 and 0.4 S m-1.
Investigation of radiofrequency plasma sources for space travel
NASA Astrophysics Data System (ADS)
Charles, C.; Boswell, R. W.; Takahashi, K.
2012-12-01
Optimization of radiofrequency (RF) plasma sources for the development of space thrusters differs from other applications such as plasma processing of materials since power efficiency, propellant usage, particle acceleration or heating become driving parameters. The development of two RF (13.56 MHz) plasma sources, the high-pressure (˜1 Torr) capacitively coupled ‘pocket rocket’ plasma micro-thruster and the low-pressure (˜1 mTorr) inductively coupled helicon double layer thruster (HDLT), is discussed within the context of mature and emerging electric propulsion devices. The density gradient in low-pressure expanding RF plasmas creates an electric field that accelerates positive ions out of the plasma. Generally, the total potential drop is similar to that of a wall sheath allowing the plasma electrons to neutralize the ion beam. A high-pressure expansion with no applied magnetic field can result in large dissociation rates and/or a collimated beam of ions of small area and a flowing heated neutral beam (‘pocket rocket’). A low-pressure expansion dominated by a magnetic field can result in the formation of electric double layers which produce a very directed neutralized beam of ions of large area (HDLT).
Evaluation of stray radiofrequency radiation emitted by electrosurgical devices
NASA Astrophysics Data System (ADS)
DeMarco, M.; Maggi, S.
2006-07-01
Electrosurgery refers to the passage of a high-frequency, high-voltage electrical current through the body to achieve the desired surgical effects. At the same time, these procedures are accompanied by a general increase of the electromagnetic field in an operating room that may expose both patients and personnel to relatively high levels of radiofrequency radiation. In the first part of this study, we have taken into account the radiation emitted by different monopolar electrosurgical devices, evaluating the electromagnetic field strength delivered by an electrosurgical handle and straying from units and other electrosurgical accessories. As a summary, in the worst case a surgeon's hands are exposed to a continuous and pulsed RF wave whose magnetic field strength is 0.75 A m-1 (E-field 400 V m-1). Occasionally stray radiation may exceed ICNIRP's occupational exposure guidelines, especially close to the patient return plate. In the second part of this paper, we have analysed areas of particular concern to prevent electromagnetic interference with some life-support devices (ventilators and electrocardiographic devices), which have failed to operate correctly. Most clinically relevant interference occurred when an electrosurgery device was used within 0.3 m of medical equipment. In the appendix, we suggest some practical recommendations intended to minimize the potential for electromagnetic hazards due to therapeutic application of RF energy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eremeev, Grigory; Geng, Rongli; Palczewski, Ari
2011-07-01
We have studied thermal breakdown in several multicell superconducting radiofrequency cavity by simultaneous excitation of two TM{sub 010} passband modes. Unlike measurements done in the past, which indicated a clear thermal nature of the breakdown, our measurements present a more complex picture with interplay of both thermal and magnetic effects. JLab LG-1 that we studied was limited at 40.5 MV/m, corresponding to B{sub peak} = 173 mT, in 8{pi}/9 mode. Dual mode measurements on this quench indicate that this quench is not purely magnetic, and so we conclude that this field is not the fundamental limit in SRF cavities.
Nb3Sn superconducting radiofrequency cavities: fabrication, results, properties, and prospects
NASA Astrophysics Data System (ADS)
Posen, S.; Hall, D. L.
2017-03-01
A microns-thick film of Nb3Sn on the inner surface of a superconducting radiofrequency (SRF) cavity has been demonstrated to substantially improve cryogenic efficiency compared to the standard niobium material, and its predicted superheating field is approximately twice as high. We review in detail the advantages of Nb3Sn coatings for SRF cavities. We describe the vapor diffusion process used to fabricate this material in the most successful experiments, and we compare the differences in the process used at different labs. We overview results of Nb3Sn SRF coatings, including CW and pulsed measurements of cavities as well as microscopic measurements. We discuss special considerations that must be practised when using Nb3Sn cavities in applications. Finally, we conclude by summarizing the state-of-the-art and describing the outlook for this alternative SRF material.
Environmental Assessment for North Warning System (Alaska)
1986-11-10
With Respect to Human Exposure to Radio Frequency Electromagnetic Fields , 300 kHz to 100 GHz, ANSI C95.1-1982, IEEE, New York. CH 2M Hill, 1981...Council on Radiation Protection and Measurements), 1986.Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields . NCRP Report...6 4.1.3.1 Radiofrequency Radiation ..................... 4-7 4.1.3.1.1 Electromagnetic Hazards.......... 4-7 4.1.3.1.2 Electromagnetic Interference
DOE Office of Scientific and Technical Information (OSTI.GOV)
Posen, S., E-mail: sposen@fnal.gov; Checchin, M.; Crawford, A. C.
2016-06-07
Even when cooled through its transition temperature in the presence of an external magnetic field, a superconductor can expel nearly all external magnetic flux. This paper presents an experimental study to identify the parameters that most strongly influence flux trapping in high purity niobium during cooldown. This is critical to the operation of superconducting radiofrequency cavities, in which trapped flux degrades the quality factor and therefore cryogenic efficiency. Flux expulsion was measured on a large survey of 1.3 GHz cavities prepared in various ways. It is shown that both spatial thermal gradient and high temperature treatment are critical to expelling externalmore » magnetic fields, while surface treatment has minimal effect. For the first time, it is shown that a cavity can be converted from poor expulsion behavior to strong expulsion behavior after furnace treatment, resulting in a substantial improvement in quality factor. Microscopic investigations are performed to study the relevant changes in the material from this treatment. Future plans are described to build on this result in order to optimize treatment for future cavities.« less
Geronikolou, Styliani; Zimeras, Stelios; Davos, Constantinos H; Michalopoulos, Ioannis; Tsitomeneas, Stephanos
2014-01-01
The impact of electromagnetic fields on health is of increasing scientific interest. The aim of this study was to examine how the Drosophila melanogaster animal model is affected when exposed to portable or mobile phone fields. Two experiments have been designed and performed in the same laboratory conditions. Insect cultures were exposed to the near field of a 2G mobile phone (the GSM 2G networks support and complement in parallel the 3G wide band or in other words the transmission of information via voice signals is served by the 2G technology in both mobile phones generations) and a 1880 MHz cordless phone both digitally modulated by human voice. Comparison with advanced statistics of the egg laying of the second generation exposed and non-exposed cultures showed limited statistical significance for the cordless phone exposed culture and statistical significance for the 900 MHz exposed insects. We calculated by physics, simulated and illustrated in three dimensional figures the calculated near fields of radiation inside the experimenting vials and their difference. Comparison of the power of the two fields showed that the difference between them becomes null when the experimental cylinder radius and the height of the antenna increase. Our results suggest a possible radiofrequency sensitivity difference in insects which may be due to the distance from the antenna or to unexplored intimate factors. Comparing the near fields of the two frequencies bands, we see similar not identical geometry in length and height from the antenna and that lower frequencies tend to drive to increased radiofrequency effects.
Radio-Frequency-Controlled Cold Collisions and Universal Properties of Unitary Bose Gases
NASA Astrophysics Data System (ADS)
Ding, Yijue
This thesis investigates two topics: ultracold atomic collisions in a radio-frequency field and universal properties of a degenerate unitary Bose gas. One interesting point of the unitary Bose gas is that the system has only one length scale, that is, the average interparticle distance. This single parameter determines all properties of the gas, which is called the universality of the system. We first introduce a renormalized contact interaction to extend the validity of the zero-range interaction to large scattering lengths. Then this renormalized interaction is applied to many-body theories to determined those universal relations of the system. From the few-body perspective, we discuss the scattering between atoms in a single-color radio-frequency field. Our motivation is proposing the radio-frequency field as an effective tool to control interactions between cold atoms. Such a technique may be useful in future experiments such as creating phase transitions in spinor condensates. We also discuss the formation of ultracold molecules using radio-freqency fields from a time-dependent approach.
Dolan, Mike; Rowley, Jack
2009-09-01
No health hazard has been established from exposure to radiofrequency fields up to the levels recommended by the International Commission on Non-Ionizing Radiation Protection. However, in response to public concern and the perceived level of scientific uncertainty, there are continuing calls for the application of the precautionary principle to radiofrequency exposures from mobile phones and base stations. We examined the international evolution of calls for precautionary measures in relation to mobile phones and base stations, with particular focus on Australia and the United Kingdom. The precautionary principle is difficult to define, and there is no widespread agreement as to how it should be implemented. However, there is a strong argument that precautionary measures should not be implemented in the absence of reliable scientific data and logical reasoning pointing to a possible health hazard. There is also experimental evidence that precautionary advice may increase public concern. We argue that conservative exposure standards, technical features that minimize unnecessary exposures, ongoing research, regular review of standards, and availability of consumer information make mobile communications inherently precautionary. Commonsense measures can be adopted by individuals, governments, and industry to address public concern while ensuring that mobile networks are developed for the benefit of society.
Radio-frequency measurement in semiconductor quantum computation
NASA Astrophysics Data System (ADS)
Han, TianYi; Chen, MingBo; Cao, Gang; Li, HaiOu; Xiao, Ming; Guo, GuoPing
2017-05-01
Semiconductor quantum dots have attracted wide interest for the potential realization of quantum computation. To realize efficient quantum computation, fast manipulation and the corresponding readout are necessary. In the past few decades, considerable progress of quantum manipulation has been achieved experimentally. To meet the requirements of high-speed readout, radio-frequency (RF) measurement has been developed in recent years, such as RF-QPC (radio-frequency quantum point contact) and RF-DGS (radio-frequency dispersive gate sensor). Here we specifically demonstrate the principle of the radio-frequency reflectometry, then review the development and applications of RF measurement, which provides a feasible way to achieve high-bandwidth readout in quantum coherent control and also enriches the methods to study these artificial mesoscopic quantum systems. Finally, we prospect the future usage of radio-frequency reflectometry in scaling-up of the quantum computing models.
Anthropogenic radiofrequency electromagnetic fields as an emerging threat to wildlife orientation.
Balmori, Alfonso
2015-06-15
The rate of scientific activity regarding the effects of anthropogenic electromagnetic radiation in the radiofrequency (RF) range on animals and plants has been small despite the fact that this topic is relevant to the fields of experimental biology, ecology and conservation due to its remarkable expansion over the past 20 years. Current evidence indicates that exposure at levels that are found in the environment (in urban areas and near base stations) may particularly alter the receptor organs to orient in the magnetic field of the earth. These results could have important implications for migratory birds and insects, especially in urban areas, but could also apply to birds and insects in natural and protected areas where there are powerful base station emitters of radiofrequencies. Therefore, more research on the effects of electromagnetic radiation in nature is needed to investigate this emerging threat. Copyright © 2015 Elsevier B.V. All rights reserved.
Coupled oscillations of vortex cores confined in a ferromagnetic elliptical disk
NASA Astrophysics Data System (ADS)
Hata, Hiroshi; Goto, Minori; Yamaguchi, Akinobu; Sato, Tomonori; Nakatani, Yoshinobu; Nozaki, Yukio
2014-09-01
By solving the Thiele equation with simultaneous application of a radio-frequency (rf) magnetic field (hrf) and an rf spin current (jsp), the dynamic susceptibility of exchange-coupled vortices in response to hrf and jsp was obtained. It was found that the four eigenmodes expected for two vortices trapped in a magnetic elliptical disk were coupled to different components of hrf and jsp. As a consequence, orthogonal hrf and jsp (which are simultaneously generated by the application of an rf current to an elliptical disk) can excite two modes with different eigenfrequencies. This result suggests that a fieldlike nonadiabatic torque caused by an rf spin current can be spectroscopically distinguished from the one caused by the rf magnetic field.
NASA Astrophysics Data System (ADS)
Rebling, Johannes; Oyaga Landa, Francisco Javier; Deán-Ben, Xosé Luis; Razansky, Daniel
2018-02-01
Electrosurgery, i.e. the application of radiofrequency current for tissue ablation, is a frequently used treatment for many cardiac arrhythmias. Electrophysiological and anatomic mapping, as well as careful radiofrequency power control typically guide the radiofrequency ablation procedure. Despite its widespread application, accurate monitoring of the lesion formation with sufficient spatio-temporal resolution remains challenging with the existing imaging techniques. We present a novel integrated catheter for simultaneous radiofrequency ablation and optoacoustic monitoring of the lesion formation in real time and 3D. The design combines the delivery of both electric current and optoacoustic excitation beam in a single catheter consisting of copper-coated multimode light-guides and its manufacturing is described in detail. The electrical current causes coagulation and desiccation while the excitation light is locally absorbed, generating OA responses from the entire treated volume. The combined ablation-monitoring capabilities were verified using ex-vivo bovine tissue. The formed ablation lesions showed a homogenous coagulation while the ablation was monitored in realtime with a volumetric frame rate of 10 Hz over 150 seconds.
Chen, Kuan-Hung; Yang, Chien-Hui; Juang, Sin-Ei; Huang, Hui-Wen; Cheng, Jen-Kun; Sheen-Chen, Shyr-Ming; Cheng, Jiin-Tsuey; Lin, Chung-Ren
2014-03-01
Pulsed radiofrequency (PRF) treatment involves the pulsed application of a radiofrequency electric field to a nerve. The technology offers pain relief for patients suffering from chronic pain who do not respond well to conventional treatments. We tested whether PRF treatment attenuated complete Freund's adjuvant (CFA) induced inflammatory pain. The profile of spinal c-Jun N-terminal kinases (JNKs) phosphorylation was evaluated to elucidate the potential mechanism. Injection of CFA into the unilateral hind paw of rats induced mechanical hyperalgesia in both the ipsilateral and contralateral hind paws. We administered 500-kHz PRF treatment in 20-ms pulses, at a rate of 2 Hz (2 pulses per second) either to the sciatic nerve in the mid-thigh, or to the L4 anterior primary ramus just distal to the intervertebral foramen in both the CFA group and no-PRF group rats. Tissue samples were examined at 1, 3, 7, and 14 days following PRF treatments. Behavioral studies showed that PRF applied close to the dorsal root ganglion (DRG) significantly attenuated CFA-induced mechanical hyperalgesia compared to no-PRF group (P < .05). And western blotting revealed significant attenuation of the activation of JNK in the spinal dorsal horn compared to no-PRF group animals (P < .05). Application of PRF close to DRG provides an effective treatment for CFA-induced persistent mechanical hyperalgesia by attenuating JNK activation in the spinal dorsal horn.
Potyrailo, Radislav A.; Surman, Cheryl
2013-01-01
Uncontrolled fluctuations of ambient temperature in the field typically greatly reduce accuracy of gas sensors. In this study, we developed an approach for the self-correction against fluctuations of ambient temperature of individual gas and vapor sensors. The main innovation of our work is in the temperature correction which is accomplished without the need for a separate uncoated reference sensor or a separate temperature sensor. Our sensors are resonant inductor-capacitor-resistor (LCR) transducers coated with sensing materials and operated as multivariable passive (battery-free) radio-frequency identification (RFID) sensors. Using our developed approach, we performed quantitation of an exemplary vapor over the temperature range from 25 to 40 °C. This technical solution will be attractive in numerous applications where temperature stabilization of a gas sensor or addition of auxiliary temperature or uncoated reference sensors is prohibitive. PMID:23956496
Nb 3Sn superconducting radiofrequency cavities: Fabrication, results, properties, and prospects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Posen, S.; Hall, D. L.
A microns-thick film of Nb 3Sn on the inner surface of a superconducting radiofrequency (SRF) cavity has been demonstrated to substantially improve cryogenic efficiency compared to the standard niobium material, and its predicted superheating field is approximately twice as high. We review in detail the advantages of Nb 3Sn coatings for SRF cavities. We describe the vapor diffusion process used to fabricate this material in the most successful experiments, and we compare the differences in the process used at different labs. We overview results of Nb 3Sn SRF coatings, including CW and pulsed measurements of cavities as well as microscopicmore » measurements. We discuss special considerations that must be practised when using Nb 3Sn cavities in applications. Lastly, we conclude by summarizing the state-of-the-art and describing the outlook for this alternative SRF material.« less
Nb 3Sn superconducting radiofrequency cavities: Fabrication, results, properties, and prospects
Posen, S.; Hall, D. L.
2017-01-23
A microns-thick film of Nb 3Sn on the inner surface of a superconducting radiofrequency (SRF) cavity has been demonstrated to substantially improve cryogenic efficiency compared to the standard niobium material, and its predicted superheating field is approximately twice as high. We review in detail the advantages of Nb 3Sn coatings for SRF cavities. We describe the vapor diffusion process used to fabricate this material in the most successful experiments, and we compare the differences in the process used at different labs. We overview results of Nb 3Sn SRF coatings, including CW and pulsed measurements of cavities as well as microscopicmore » measurements. We discuss special considerations that must be practised when using Nb 3Sn cavities in applications. Lastly, we conclude by summarizing the state-of-the-art and describing the outlook for this alternative SRF material.« less
Direct amide formation using radiofrequency heating.
Houlding, Thomas K; Tchabanenko, Kirill; Rahman, Md Taifur; Rebrov, Evgeny V
2013-07-07
We present a simple method for direct and solvent-free formation of amides from carboxylic acids and amines using radiofrequency heating. The direct energy coupling of the AC magnetic field via nickel ferrite magnetic nanoparticles enables fast and controllable heating, as well as enabling facile work-up via magnetic separation.
Geronikolou, Styliani; Zimeras, Stelios; Davos, Constantinos H.; Michalopoulos, Ioannis; Tsitomeneas, Stephanos
2014-01-01
Introduction The impact of electromagnetic fields on health is of increasing scientific interest. The aim of this study was to examine how the Drosophila melanogaster animal model is affected when exposed to portable or mobile phone fields. Methods/Results Two experiments have been designed and performed in the same laboratory conditions. Insect cultures were exposed to the near field of a 2G mobile phone (the GSM 2G networks support and complement in parallel the 3G wide band or in other words the transmission of information via voice signals is served by the 2G technology in both mobile phones generations) and a 1880 MHz cordless phone both digitally modulated by human voice. Comparison with advanced statistics of the egg laying of the second generation exposed and non-exposed cultures showed limited statistical significance for the cordless phone exposed culture and statistical significance for the 900 MHz exposed insects. We calculated by physics, simulated and illustrated in three dimensional figures the calculated near fields of radiation inside the experimenting vials and their difference. Comparison of the power of the two fields showed that the difference between them becomes null when the experimental cylinder radius and the height of the antenna increase. Conclusions/Significance Our results suggest a possible radiofrequency sensitivity difference in insects which may be due to the distance from the antenna or to unexplored intimate factors. Comparing the near fields of the two frequencies bands, we see similar not identical geometry in length and height from the antenna and that lower frequencies tend to drive to increased radiofrequency effects. PMID:25402465
2009-09-01
evaluate specific system equipment func- tions, performance, operations, and safety in the field environment. The planned test procedures require free space...emission of radiofrequency (RF) electromagnetic energy within a limited spectral region and controlled power spec- tral density. There would be...for personnel. The applicable DoD standard that provides required guidelines for permissible exposure limits of DoD personnel is DoD Instruction
Cockburn, J F; Maddern, G J; Wemyss-Holden, S A
2007-03-01
To examine the effect of applying increasing amounts of direct current (DC) before and during alternating current radiofrequency ablation of porcine liver. Using a Radiotherapeutics RF3000 generator, a 9 V AC/DC transformer and a 16 G plain aluminium tube as an electrode, a control group of 24 porcine hepatic radiofrequency ablation zones was compared with 24 zones created using a bimodal electric tissue ablation (BETA) technique in three pigs. All ablations were terminated when tissue impedance rose to greater than 999 Omega or radiofrequency energy input fell below 5 W on three successive measurements taken at 1 min intervals. BETA ablations were performed in two phases: an initial phase of variable duration DC followed by a second phase during which standard radiofrequency ablation was applied simultaneously with DC. During this second phase, radiofrequency power input was regulated by the feedback circuitry of the RF3000 generator according to changes in tissue impedance. The diameters (mm) of each ablation zone were measured by two observers in two planes perpendicular to the plane of needle insertion. The mean short axis diameter of each ablation zone was subjected to statistical analysis. With increased duration of prior application of DC, there was a progressive increase in the diameter of the ablation zone (p<0.001). This effect increased sharply up to 300 s of pre-treatment after which a further increase in diameter occurred, but at a much lesser rate. A maximum ablation zone diameter of 32 mm was produced (control diameters 10-13 mm). Applying a 9 V DC to porcine liver in vivo, and continuing this DC application during subsequent radiofrequency ablation, results in larger ablation zone diameters compared with radiofrequency ablation alone.
Percutaneous radiofrequency treatment for refractory anteromedial pain of osteoarthritic knees.
Ikeuchi, Masahiko; Ushida, Takahiro; Izumi, Masashi; Tani, Toshikazu
2011-04-01
Although severe knee osteoarthritis with refractory pain is commonly treated surgically, this is often not an option for patients with poor health status or unwillingness to undergo major surgery. We examined the efficacy of radiofrequency application to sensory nerves as a novel alternative treatment for refractory knee pain. This study was an open-label, nonrandomized, and controlled study. Patients complaining of refractory anteromedial knee pain associated with radiological osteoarthritis (moderate or severe) were included. They were assigned to one of two groups: those receiving radiofrequency thermocoagulation (N = 18) or those receiving nerve block (N = 17), depending on the time period that they were referred to the clinic. Radiofrequency current or local anesthetics was applied to the medial retinacular nerve and the infrapatellar branch of the saphenous nerve. Western Ontario McMaster Universities osteoarthritis index score, pain visual analog scale (VAS), and patient's global assessment were assessed with a minimum follow-up of 6 months. Radiofrequency treatment significantly decreased knee pain as measured by VAS for 12 weeks compared with the control group. In terms of responders, more patients in the RF group responded to the treatment than in the control group. The differences were statistically significant at 4 weeks, 8 weeks, and 12 weeks in pain VAS. Eight patients (44%) treated with radiofrequency rated excellent or good but only three (18%) in the control group rated good, although the difference was not statistically significant. Some patients were able to benefit substantially from radiofrequency treatment. Even if its effective period is limited, radiofrequency application is a promising treatment to alleviate refractory anteromedial knee pain with osteoarthritis. Further experience and technical improvements are needed to establish its role in the management of knee osteoarthritis. Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lamb, J; Low, D; Mutic, S
Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency ofmore » 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was funded by ViewRay, Inc., Oakwood, OH.« less
Dover, Jeffrey S.; Rothaus, Kenneth
2014-01-01
Stretch marks are common skin disorders that are dermal scars with associated epidermal atrophy. They are of significant concern or psychological concern to many. This manuscript describes the use of multipolar radiofrequency with pulsed magnetic fields that was successfully used to diminish these lesions in 16 subjects undergoing a series of treatments. The improvements noted were statistically significant and no serious adverse events were noted. PMID:25276274
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-17
... of Radiofrequency, Second Memorandum Opinion and Order, ET Docket No. 93-62. Form Number: N/A. Type... issue of radiofrequency radiation from FCC-regulated transmitters. The Commission requires applicants to...
Sheppard, Asher R; Swicord, Mays L; Balzano, Quirino
2008-10-01
The complexity of interactions of electromagnetic fields up to 10(12) Hz with the ions, atoms, and molecules of biological systems has given rise to a large number of established and proposed biophysical mechanisms applicable over a wide range of time and distance scales, field amplitudes, frequencies, and waveforms. This review focuses on the physical principles that guide quantitative assessment of mechanisms applicable for exposures at or below the level of endogenous electric fields associated with development, wound healing, and excitation of muscles and the nervous system (generally, 1 to 10(2) V m(-1)), with emphasis on conditions where temperature increases are insignificant (<1 K). Experiment and theory demonstrate possible demodulation at membrane barriers for frequencies < or =10 MHz, but not at higher frequencies. Although signal levels somewhat below system noise can be detected, signal-to-noise ratios substantially less than 0.1 cannot be overcome by cooperativity, signal averaging, coherent detection, or by nonlinear dynamical systems. Sensory systems and possible effects on biological magnetite suggest paradigms for extreme sensitivity at lower frequencies, but there are no known radiofrequency (RF) analogues. At the molecular level, vibrational modes are so overdamped by water molecules that excitation of molecular modes below the far infrared cannot occur. Two RF mechanisms plausibly may affect biological matter under common exposure conditions. For frequencies below approximately 150 MHz, shifts in the rate of chemical reactions can be mediated by radical pairs and, at all frequencies, dielectric and resistive heating can raise temperature and increase the entropy of the affected biological system.
NASA Astrophysics Data System (ADS)
del Hougne, Philipp; Fink, Mathias; Lerosey, Geoffroy
2017-12-01
Wave-front shaping has emerged over the past decade as a powerful tool to control wave propagation through complex media, initially in optics and more recently also in the microwave domain with important applications in telecommunication, imaging, and energy transfer. The crux of implementing wave-front shaping concepts in real life is often its need for (direct) feedback, requiring access to the target to focus on. Here, we present the shaping of a microwave field based on indirect, unsolicited, and blind feedback which may be the pivotal step towards practical implementations. With the example of a radio-frequency harvester in a metallic cavity, we demonstrate tenfold enhancement of the harvested power by wave-front shaping based on nonlinear signals detected at an arbitrary position away from the harvesting device.
Yin, Hai-Dong; Zhang, Xin-Mei; Huang, Ming-Guang; Chen, Wei; Song, Yang; Du, Qing-Jun; Wu, Yu-Ning; Yang, Ruo-Bin
2017-04-01
This study aims to investigate the curative effects and mechanism of radiofrequency ablation nucleoplasty in the treatment of cervical vertigo. A total of 27 patients diagnosed with cervical vertigo from January 2012 to October 2014 received treatment of radiofrequency ablation nucleoplasty. The narrow-side vertebral artery diameters were examined by using Philips 1.5-T body dual-gradient MRI system. The haemodynamic parameters were detected by using transcranial Doppler sonography. Both of the vertebral artery diameters and haemodynamic parameters were recorded and compared before and after treatment. The curative effects in early post-operative application were evaluated according to the Nagashima standards. Radiofrequency ablation nucleoplasty was performed in a total of 59 cervical discs in 27 patients. The average operation time was 42.7 min, and the symptoms of 92.6% patients were alleviated after radiofrequency ablation nucleoplasty post-operation application. There was no significant difference in the narrow-side vertebral artery diameters before and after treatment in both Group A (p = 0.12) and Group B (p = 0.48); however, the blood flow velocity was significantly higher than that before treatment in both Group A (p = 0.01) and Group B (p = 0.03), respectively. Radiofrequency ablation nucleoplasty improves the blood flow in the narrow-side vertebral artery and illustrates the therapeutic effect on cervical vertigo in patients who have no direct compression of the vertebral artery. Advances in knowledge: Radiofrequency intradiscal nucleoplasty can be used as a minimally invasive procedure for treating cervical vertigo.
Nikolo, Martin; Singleton, John; Zapf, Vivien S.; ...
2016-07-20
The de-pinning or irreversibility lines were determined by ac susceptibility, magnetization, radio-frequency proximity detector oscillator (PDO), and resistivity methods in Ba(Fe 0.92Co 0.08) 2As 2 ( T c = 23.2 K), Ba(Fe 0.95Ni 0.05) 2As 2 ( T c = 20.4 K), and Ba(Fe 0.94Ni 0.06) 2As 2 ( T c = 18.5 K) bulk superconductors in ac, dc, and pulsed magnetic fields up to 65 T. A new method of extracting the irreversibility fields from the radio-frequency proximity detector oscillator induction technique is described. Wide temperature broadening of the irreversibility lines, for any given combination of ac and dcmore » fields, is dependent on the time frame of measurement. Increasing the magnetic field sweep rate (dH/dt) shifts the irreversibility lines to higher temperatures up to about dH/d t = 40,000 Oe/s; for higher dH/dt, there is little impact on the irreversibility line. There is an excellent data match between the irreversibility fields obtained from magnetization hysteresis loops, PDO, and ac susceptibility measurements, but not from resistivity measurements in these materials. Lower critical field vs. temperature phase diagrams are measured. Their very low values near 0 T indicate that these materials are in mixed state in nonzero magnetic fields, and yet the strength of the vortex pinning enables very high irreversibility fields, as high as 51 T at 1.5 K for the Ba(Fe 0.92Co 0.08) 2As 2 polycrystalline sample, showing a promise for liquid helium temperature applications.« less
The Precautionary Principle in the Context of Mobile Phone and Base Station Radiofrequency Exposures
Dolan, Mike; Rowley, Jack
2009-01-01
Background No health hazard has been established from exposure to radiofrequency fields up to the levels recommended by the International Commission on Non-Ionizing Radiation Protection. However, in response to public concern and the perceived level of scientific uncertainty, there are continuing calls for the application of the precautionary principle to radiofrequency exposures from mobile phones and base stations. Objective We examined the international evolution of calls for precautionary measures in relation to mobile phones and base stations, with particular focus on Australia and the United Kingdom. Results The precautionary principle is difficult to define, and there is no widespread agreement as to how it should be implemented. However, there is a strong argument that precautionary measures should not be implemented in the absence of reliable scientific data and logical reasoning pointing to a possible health hazard. There is also experimental evidence that precautionary advice may increase public concern. Conclusion We argue that conservative exposure standards, technical features that minimize unnecessary exposures, ongoing research, regular review of standards, and availability of consumer information make mobile communications inherently precautionary. Commonsense measures can be adopted by individuals, governments, and industry to address public concern while ensuring that mobile networks are developed for the benefit of society. PMID:19750093
A digital low-level radio-frequency system R&D for a 1.3 GHz nine-cell cavity
NASA Astrophysics Data System (ADS)
Qiu, Feng; Gao, Jie; Lin, Hai-Ying; Liu, Rong; Ma, Xin-Peng; Sha, Peng; Sun, Yi; Wang, Guang-Wei; Wang, Qun-Yao; Xu, Bo
2012-03-01
To test and verify the performance of the digital low-level radio-frequency (LLRF) and tuner system designed by the IHEP RF group, an experimental platform with a retired KEK 1.3 GHz nine-cell cavity is set up. A radio-frequency (RF) field is established successfully in the cavity and the frequency of the cavity is locked by the tuner in ±0.5° (about ±1.2 kHz) at room temperature. The digital LLRF system performs well in a five-hour experiment, and the results show that the system achieves field stability at amplitude <0.1% (peak to peak) and phase <0.1° (peak to peak). This index satisfies the requirements of the International Linear Collider (ILC), and this paper describes this closed-loop experiment of the LLRF system.
Pregnancy outcomes after paternal radiofrequency field exposure aboard fast patrol boats.
Baste, Valborg; Moen, Bente E; Oftedal, Gunnhild; Strand, Leif Age; Bjørge, Line; Mild, Kjell Hansson
2012-04-01
To investigate adverse reproductive outcomes among male employees in the Royal Norwegian Navy exposed to radiofrequency electromagnetic fields aboard fast patrol boats. Cohort study of Royal Norwegian Navy servicemen linked to the Medical Birth Registry of Norway, including singleton offspring born between 1967 and 2008 (n = 37,920). Exposure during the last 3 months before conception (acute) and exposure more than 3 months before conception (nonacute) were analyzed. Perinatal mortality and preeclampsia increased after service aboard fast patrol boats during an acute period and also after increased estimated radiofrequency exposure during an acute period, compared with service aboard other vessels. No associations were found between nonacute exposure and any of the reproductive outcomes. Paternal work aboard fast patrol boats during an acute period was associated with perinatal mortality and preeclampsia, but the cause is not clear.
NASA Astrophysics Data System (ADS)
Lara, Nadia C.; Haider, Asad A.; Wilson, Lon J.; Curley, Steven A.; Corr, Stuart J.
2017-01-01
Aqueous and nanoparticle-based solutions have been reported to heat when exposed to an alternating radiofrequency (RF) electric-field. Although the theoretical models have been developed to accurately model such a behavior given the solution composition as well as the geometrical constraints of the sample holder, these models have not been investigated across a wide-range of solutions where the dielectric properties differ, especially with regard to the real permittivity. In this work, we investigate the RF heating properties of non-aqueous solutions composed of ethanol, propylene glycol, and glycine betaine with and without varying amounts of NaCl and LiCl. This allowed us to modulate the real permittivity across the range 25-132, as well as the imaginary permittivity across the range 37-177. Our results are in excellent agreement with the previously developed theoretical models. We have shown that different materials generate unique RF heating curves that differ from the standard aqueous heating curves. The theoretical model previously described is robust and accounts for the RF heating behavior of materials with a variety of dielectric properties, which may provide applications in non-invasive RF cancer hyperthermia.
Kim, Gyu-Nam; Yoo, Woong-Sun; Kim, Seong-Jae; Han, Yong-Seop; Chung, In-Young; Park, Jong-Moon; Yoo, Ji-Myong
2014-01-01
Purpose To investigate the inhibitory effect of 0.02% mitomycin C on eyelash regrowth when injected to the eyelash hair follicle immediately after radiofrequency ablation. Methods We prospectively included 21 trichiasis patients from June 2011 to October 2012. Twenty eyes of 14 patients were treated with 0.02% mitomycin C to the hair follicle immediately after radiofrequency ablation in group 1, while radiofrequency ablation only was conducted in ten eyes of seven patients in group 2. Recurrences and complications were evaluated until six months after treatment. Results One hundred sixteen eyelashes of 20 eyes in group 1 underwent treatment, and 19 (16.4%) eyelashes recurred. Eighty-four eyelashes of ten eyes in group 2 underwent treatment, and 51 (60.7%) eyelashes recurred. No patients developed any complications related to mitomycin C. Conclusions Application of 0.02% mitomycin C in conjunction with radiofrequency ablation may help to improve the success rate of radiofrequency ablation treatment in trichiasis patients. PMID:24505196
Reconfigurable radio-frequency arbitrary waveforms synthesized in a silicon photonic chip.
Wang, Jian; Shen, Hao; Fan, Li; Wu, Rui; Niu, Ben; Varghese, Leo T; Xuan, Yi; Leaird, Daniel E; Wang, Xi; Gan, Fuwan; Weiner, Andrew M; Qi, Minghao
2015-01-12
Photonic methods of radio-frequency waveform generation and processing can provide performance advantages and flexibility over electronic methods due to the ultrawide bandwidth offered by the optical carriers. However, bulk optics implementations suffer from the lack of integration and slow reconfiguration speed. Here we propose an architecture of integrated photonic radio-frequency generation and processing and implement it on a silicon chip fabricated in a semiconductor manufacturing foundry. Our device can generate programmable radio-frequency bursts or continuous waveforms with only the light source, electrical drives/controls and detectors being off-chip. It modulates an individual pulse in a radio-frequency burst within 4 ns, achieving a reconfiguration speed three orders of magnitude faster than thermal tuning. The on-chip optical delay elements offer an integrated approach to accurately manipulating individual radio-frequency waveform features without constraints set by the speed and timing jitter of electronics, and should find applications ranging from high-speed wireless to defence electronics.
Reconfigurable radio-frequency arbitrary waveforms synthesized in a silicon photonic chip
Wang, Jian; Shen, Hao; Fan, Li; Wu, Rui; Niu, Ben; Varghese, Leo T.; Xuan, Yi; Leaird, Daniel E.; Wang, Xi; Gan, Fuwan; Weiner, Andrew M.; Qi, Minghao
2015-01-01
Photonic methods of radio-frequency waveform generation and processing can provide performance advantages and flexibility over electronic methods due to the ultrawide bandwidth offered by the optical carriers. However, bulk optics implementations suffer from the lack of integration and slow reconfiguration speed. Here we propose an architecture of integrated photonic radio-frequency generation and processing and implement it on a silicon chip fabricated in a semiconductor manufacturing foundry. Our device can generate programmable radio-frequency bursts or continuous waveforms with only the light source, electrical drives/controls and detectors being off-chip. It modulates an individual pulse in a radio-frequency burst within 4 ns, achieving a reconfiguration speed three orders of magnitude faster than thermal tuning. The on-chip optical delay elements offer an integrated approach to accurately manipulating individual radio-frequency waveform features without constraints set by the speed and timing jitter of electronics, and should find applications ranging from high-speed wireless to defence electronics. PMID:25581847
APPLICATION OF A FINITE-DIFFERENCE TECHNIQUE TO THE HUMAN RADIOFREQUENCY DOSIMETRY PROBLEM
A powerful finite difference numerical technique has been applied to the human radiofrequency dosimetry problem. The method possesses inherent advantages over the method of moments approach in that its implementation requires much less computer memory. Consequently, it has the ca...
NASA Astrophysics Data System (ADS)
Guo, Xiaohui; Huang, Ying; Wu, Can; Mao, Leidong; Wang, Yue; Xie, Zhicheng; Liu, Caixia; Zhang, Yugang
2017-10-01
We demonstrated a flexible and reversibly deformable radio-frequency antenna based on SWCNTs/PANI/Lycra conductive fabric and semipermeable film for wireless wearable communications applications. The conductive fabric fabricated by using the ‘dip and dry’ process exhibits good flexibility, electrical stability, stretchability and mechanical properties, and a high electrical conductivity (with low sheet resistance of ˜35 Ω/sq) was obtained based on the SWCNTs/PANI synergistic conductive network. The morphology of the semipermeable film was investigated to further illustrate the waterproof breathable features. Meanwhile, the modeling, fabrication procedure and radiating properties of the radio-frequency textile antenna worked at 2.45 GHz were systematically illustrated. The measured reflection coefficient, VSWR and the -10 dB bandwidth is ˜-18.6 dB, 1.58 and ˜270 MHz respectively, which agreed well with the simulation results. Furthermore, the results indicate that the design methodology for the radio-frequency textile antenna could have promising applications in flexible and reversibly deformable antennas for wearable wireless communications systems.
Winter, Lukas; Özerdem, Celal; Hoffmann, Werner; Santoro, Davide; Müller, Alexander; Waiczies, Helmar; Seemann, Reiner; Graessl, Andreas; Wust, Peter; Niendorf, Thoralf
2013-01-01
This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B0≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employed. Electromagnetic field simulations (EMF) were performed to study RF heating versus RF wavelength (frequency range: 64 MHz (1.5T) to 600 MHz (14.0T)). The experimental version of the applicator was implemented at B0 = 7.0T. The applicators feasibility for targeted RF heating was evaluated in EMF simulations and in phantom studies. Temperature co-simulations were conducted in phantoms and in a human voxel model. Our results demonstrate that higher frequencies afford a reduction in the size of specific absorption rate (SAR) hotspots. At 7T (298 MHz) the hybrid applicator yielded a 50% iso-contour SAR (iso-SAR-50%) hotspot with a diameter of 43 mm. At 600 MHz an iso-SAR-50% hotspot of 26 mm in diameter was observed. RF power deposition per RF input power was found to increase with B0 which makes targeted RF heating more efficient at higher frequencies. The applicator was capable of generating deep-seated temperature hotspots in phantoms. The feasibility of 2D steering of a SAR/temperature hotspot to a target location was demonstrated by the induction of a focal temperature increase (ΔT = 8.1 K) in an off-center region of the phantom. Temperature simulations in the human brain performed at 298 MHz showed a maximum temperature increase to 48.6C for a deep-seated hotspot in the brain with a size of (19×23×32)mm3 iso-temperature-90%. The hybrid applicator provided imaging capabilities that facilitate high spatial resolution brain MRI. To conclude, this study outlines the technical underpinnings and demonstrates the basic feasibility of an 8-channel hybrid TX/RX applicator that supports MR imaging, MR thermometry and targeted RF heating in one device. PMID:23613896
Winter, Lukas; Özerdem, Celal; Hoffmann, Werner; Santoro, Davide; Müller, Alexander; Waiczies, Helmar; Seemann, Reiner; Graessl, Andreas; Wust, Peter; Niendorf, Thoralf
2013-01-01
This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B0≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employed. Electromagnetic field simulations (EMF) were performed to study RF heating versus RF wavelength (frequency range: 64 MHz (1.5T) to 600 MHz (14.0T)). The experimental version of the applicator was implemented at B0 = 7.0T. The applicators feasibility for targeted RF heating was evaluated in EMF simulations and in phantom studies. Temperature co-simulations were conducted in phantoms and in a human voxel model. Our results demonstrate that higher frequencies afford a reduction in the size of specific absorption rate (SAR) hotspots. At 7T (298 MHz) the hybrid applicator yielded a 50% iso-contour SAR (iso-SAR-50%) hotspot with a diameter of 43 mm. At 600 MHz an iso-SAR-50% hotspot of 26 mm in diameter was observed. RF power deposition per RF input power was found to increase with B0 which makes targeted RF heating more efficient at higher frequencies. The applicator was capable of generating deep-seated temperature hotspots in phantoms. The feasibility of 2D steering of a SAR/temperature hotspot to a target location was demonstrated by the induction of a focal temperature increase (ΔT = 8.1 K) in an off-center region of the phantom. Temperature simulations in the human brain performed at 298 MHz showed a maximum temperature increase to 48.6C for a deep-seated hotspot in the brain with a size of (19×23×32)mm(3) iso-temperature-90%. The hybrid applicator provided imaging capabilities that facilitate high spatial resolution brain MRI. To conclude, this study outlines the technical underpinnings and demonstrates the basic feasibility of an 8-channel hybrid TX/RX applicator that supports MR imaging, MR thermometry and targeted RF heating in one device.
Aerts, Sam; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout
2013-10-01
In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information-inside hotspots or in search of them-based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km2. In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. Copyright © 2013 Elsevier Inc. All rights reserved.
Eibofner, Frank; Martirosian, Petros; Würslin, Christian; Graf, Hansjörg; Syha, Roland; Clasen, Stephan
2015-11-01
In interventional magnetic resonance imaging, instruments can be equipped with conducting wires for visualization by current application. The potential of sequence triggered application of transient direct currents in balanced steady-state free precession (bSSFP) imaging is demonstrated. A conductor and a modified catheter were examined in water phantoms and in an ex vivo porcine liver. The current was switched by a trigger pulse in the bSSFP sequence in an interval between radiofrequency pulse and signal acquisition. Magnitude and phase images were recorded. Regions with transient field alterations were evaluated by a postprocessing algorithm. A phase mask was computed and overlaid with the magnitude image. Transient field alterations caused continuous phase shifts, which were separated by the postprocessing algorithm from phase jumps due to persistent field alterations. The overlaid images revealed the position of the conductor. The modified catheter generated visible phase offset in all orientations toward the static magnetic field and could be unambiguously localized in the ex vivo porcine liver. The application of a sequence triggered, direct current in combination with phase imaging allows conspicuous localization of interventional devices with a bSSFP sequence.
Blettner, M; Berg, G
2000-01-01
There is increasing public interest in health risks of mobile phone use. Although there is a vast body of material on the biological effects of radiofrequency fields, current risk assessment is still limited. The article describes several hypotheses and results of biological effects such as thermal effect, genetic and carcinogenic effects and cancer related investigations. Mobile phones transmit and receive waves of frequencies mainly at 800-1800 MHz. Findings on the thermal effect of acute exposure to radiofrequency fields were consistent, resulting in an increase of cellular, tissue or body temperature by 1 degree C or more. Guidelines for risk limits are based on this thermal effect. Experimental investigation suggests that radiofrequency fields are not tumor initiators and that if they are related to carcinogenicity, this would be by tumor promotion or by increasing the uptake of carcinogens in cells. Implications of these experimental results on public health concerns are yet unclear. Few epidemiological studies are available on the use of mobile phones or on the radiofrequency exposure and the development of cancer. Most of these studies have no or little quantitative exposure data and they are limited by the small number of observations. Large epidemiological studies are necessary in order to investigate the use of mobile phones on the development of cancer. It should be emphasized that even a small elevated risk may have a large implication for public health, as the use of mobile phones and the exposure is rapidly increasing.
Ikeda, Atsushi; Nakagawa, Hiroshi; Lambert, Hendrik; Shah, Dipen C; Fonck, Edouard; Yulzari, Aude; Sharma, Tushar; Pitha, Jan V; Lazzara, Ralph; Jackman, Warren M
2014-12-01
Electrode-tissue contact force (CF) is believed to be a major factor in radiofrequency lesion size. The purpose of this study was to determine, in the beating canine heart, the relationship between CF and radiofrequency lesion size and the accuracy of predicting CF and lesion size by measuring electrogram amplitude, impedance, and electrode temperature. Eight dogs were studied closed chest. Using a 7F catheter with a 3.5 mm irrigated electrode and CF sensor (TactiCath, St. Jude Medical), radiofrequency applications were delivered to 3 separate sites in the right ventricle (30 W, 60 seconds, 17 mL/min irrigation) and 3 sites in the left ventricle (40 W, 60 seconds, 30 mL/min irrigation) at (1) low CF (median 8 g); (2) moderate CF (median 21 g); and (3) high CF (median 60 g). Dogs were euthanized and lesion size was measured. At constant radiofrequency and time, lesion size increased significantly with increasing CF (P<0.01). The incidence of a steam pop increased with both increasing CF and higher power. Peak electrode temperature correlated poorly with lesion size. The decrease in impedance during the radiofrequency application correlated well with lesion size for lesions in the left ventricle but less well for lesions in the right ventricle. There was a poor relationship between CF and the amplitude of the bipolar or unipolar ventricular electrogram, unipolar injury current, and impedance. Radiofrequencylesion size and the incidence of steam pop increase strikingly with increasing CF. Electrogram parameters and initial impedance are poor predictors of CF for radiofrequency ablation. © 2014 American Heart Association, Inc.
Enhanced Radiofrequency Ablation With Magnetically Directed Metallic Nanoparticles.
Nguyen, Duy T; Tzou, Wendy S; Zheng, Lijun; Barham, Waseem; Schuller, Joseph L; Shillinglaw, Benjamin; Quaife, Robert A; Sauer, William H
2016-05-01
Remote heating of metal located near a radiofrequency ablation source has been previously demonstrated. Therefore, ablation of cardiac tissue treated with metallic nanoparticles may improve local radiofrequency heating and lead to larger ablation lesions. We sought to evaluate the effect of magnetic nanoparticles on tissue sensitivity to radiofrequency energy. Ablation was performed using an ablation catheter positioned with 10 g of force over prepared ex vivo specimens. Tissue temperatures were measured and lesion volumes were acquired. An in vivo porcine thigh model was used to study systemically delivered magnetically guided iron oxide (FeO) nanoparticles during radiofrequency application. Magnetic resonance imaging and histological staining of ablated tissue were subsequently performed as a part of ablation lesion analysis. Ablation of ex vivo myocardial tissue treated with metallic nanoparticles resulted in significantly larger lesions with greater impedance changes and evidence of increased thermal conductivity within the tissue. Magnet-guided localization of FeO nanoparticles within porcine thigh preps was demonstrated by magnetic resonance imaging and iron staining. Irrigated ablation in the regions with greater FeO, after FeO infusion and magnetic guidance, created larger lesions without a greater incidence of steam pops. Metal nanoparticle infiltration resulted in significantly larger ablation lesions with altered electric and thermal conductivity. In vivo magnetic guidance of FeO nanoparticles allowed for facilitated radiofrequency ablation without direct infiltration into the targeted tissue. Further research is needed to assess the clinical applicability of this ablation strategy using metallic nanoparticles for the treatment of cardiac arrhythmias. © 2016 American Heart Association, Inc.
Viel, J F; Clerc, S; Barrera, C; Rymzhanova, R; Moissonnier, M; Hours, M; Cardis, E
2009-08-01
Both the public perceptions, and most published epidemiologic studies, rely on the assumption that the distance of a particular residence from a base station or a broadcast transmitter is an appropriate surrogate for exposure to radiofrequency fields, although complex propagation characteristics affect the beams from antennas. The main goal of this study was to characterise the distribution of residential exposure from antennas using personal exposure meters. A total of 200 randomly selected people were enrolled. Each participant was supplied with a personal exposure meter for 24 h measurements, and kept a time-location-activity diary. Two exposure metrics for each radiofrequency were then calculated: the proportion of measurements above the detection limit (0.05 V/m), and the maximum electric field strength. Residential address was geocoded, and distance from each antenna was calculated. Much of the time, the recorded field strength was below the detection level (0.05 V/m), the FM band standing apart with a proportion above the detection threshold of 12.3%. The maximum electric field strength was always lower than 1.5 V/m. Exposure to GSM and DCS waves peaked around 280 m and 1000 m from the antennas. A downward trend was found within a 10 km range for FM. Conversely, UMTS, TV 3, and TV 4&5 signals did not vary with distance. Despite numerous limiting factors entailing a high variability in radiofrequency exposure assessment, but owing to a sound statistical technique, we found that exposures from GSM and DCS base stations increase with distance in the near source zone, to a maximum where the main beam intersects the ground. We believe these results will contribute to the ongoing public debate over the location of base stations and their associated emissions.
NASA Astrophysics Data System (ADS)
Qiu, Feng; Michizono, Shinichiro; Miura, Takako; Matsumoto, Toshihiro; Liu, Na; Wibowo, Sigit Basuki
2018-03-01
A Low-level radio-frequency (LLRF) control systems is required to regulate the rf field in the rf cavity used for beam acceleration. As the LLRF system is usually complex, testing of the basic functions or control algorithms of this system in real time and in advance of beam commissioning is strongly recommended. However, the equipment necessary to test the LLRF system, such as superconducting cavities and high-power rf sources, is very expensive; therefore, we have developed a field-programmable gate array (FPGA)-based cavity simulator as a substitute for real rf cavities. Digital models of the cavity and other rf systems are implemented in the FPGA. The main components include cavity baseband models for the fundamental and parasitic modes, a mechanical model of the Lorentz force detuning, and a model of the beam current. Furthermore, in our simulator, the disturbance model used to simulate the power-supply ripples and microphonics is also carefully considered. Based on the presented cavity simulator, we have established an LLRF system test bench that can be applied to different cavity operational conditions. The simulator performance has been verified by comparison with real cavities in KEK accelerators. In this paper, the development and implementation of this cavity simulator is presented first, and the LLRF test bench based on the presented simulator is constructed. The results are then compared with those for KEK accelerators. Finally, several LLRF applications of the cavity simulator are illustrated.
Electromagnetic Fields and Public Health: Mobile Phones
... Ebola virus disease » Home / News / Fact sheets / Detail Electromagnetic fields and public health: mobile phones 8 October ... fixed antennas called base stations. Radiofrequency waves are electromagnetic fields, and unlike ionizing radiation such as X- ...
NMR apparatus for in situ analysis of fuel cells
Gerald, II, Rex E; Rathke, Jerome W
2012-11-13
The subject apparatus is a fuel cell toroid cavity detector for in situ analysis of samples through the use of nuclear magnetic resonance. The toroid cavity detector comprises a gas-tight housing forming a toroid cavity where the housing is exposed to an externally applied magnetic field B.sub.0 and contains fuel cell component samples to be analyzed. An NMR spectrometer is electrically coupled and applies a radiofrequency excitation signal pulse to the detector to produce a radiofrequency magnetic field B.sub.1 in the samples and in the toroid cavity. Embedded coils modulate the static external magnetic field to provide a means for spatial selection of the recorded NMR signals.
NASA Astrophysics Data System (ADS)
Glazer, Evan Scott
Intracellular hyperthermic therapy may prove to be a unique and novel approach to the management of pancreatic cancer. Utilizing the principle of photothermal destruction, selective killing of cancer cells with minimal injury to normal tissues may be possible. This dissertation investigated the role of antibody targeted metal nanoparticles and the cytotoxic effects of nonionizing radiofrequency fields in pancreatic cancer. Cancer cell death was induced by heat release from intracellular metal nanoparticles after radiofrequency field exposure. Fluorescent and gold nanoparticles were delivered with two antibodies, cetuximab and PAM-4, to pancreatic cancer cells in vitro and mouse xenografts in vivo. Selective delivery of these nanoparticles induced cell death in vitro and decreased tumor burden in vivo after whole animal RF field exposure. This occurred through both apoptosis and necrosis. In addition, activated caspase-3 was increased after antibody treatment and RF field exposure. Furthermore, although there was non-specific uptake by the liver and spleen in vivo, there was no evidence of acute or chronic toxicity in the animals. These results are in agreement with the principle that malignant cells are more thermally sensitive than normal cells or tissues. Selective intracellular delivery of metal nanoparticles coupled with whole body RF field exposure may be a beneficial therapy against micrometastases and unresectable pancreatic cancer in the future. Further studies are planned with more specific antibodies, other nanoparticles, and other cancer targets.
Multiparametric imaging with heterogeneous radiofrequency fields
NASA Astrophysics Data System (ADS)
Cloos, Martijn A.; Knoll, Florian; Zhao, Tiejun; Block, Kai T.; Bruno, Mary; Wiggins, Graham C.; Sodickson, Daniel K.
2016-08-01
Magnetic resonance imaging (MRI) has become an unrivalled medical diagnostic technique able to map tissue anatomy and physiology non-invasively. MRI measurements are meticulously engineered to control experimental conditions across the sample. However, residual radiofrequency (RF) field inhomogeneities are often unavoidable, leading to artefacts that degrade the diagnostic and scientific value of the images. Here we show that, paradoxically, these artefacts can be eliminated by deliberately interweaving freely varying heterogeneous RF fields into a magnetic resonance fingerprinting data-acquisition process. Observations made based on simulations are experimentally confirmed at 7 Tesla (T), and the clinical implications of this new paradigm are illustrated with in vivo measurements near an orthopaedic implant at 3T. These results show that it is possible to perform quantitative multiparametric imaging with heterogeneous RF fields, and to liberate MRI from the traditional struggle for control over the RF field uniformity.
Experimental analysis of a TEM plane transmission line for DNA studies at 900 MHz EM fields
NASA Astrophysics Data System (ADS)
Belloni, F.; Doria, D.; Lorusso, A.; Nassisi, V.; Velardi, L.; Alifano, P.; Monaco, C.; Talà, A.; Tredici, M.; Rainò, A.
2006-07-01
A suitable plane transmission line was developed and its behaviour analysed at 900 MHz radiofrequency fields to study DNA mutability and the repair of micro-organisms. In this work, utilizing such a device, we investigated the behaviour of DNA mutability and repair of Escherichia coli strains. The transmission line was very simple and versatile in changing its characteristic resistance and field intensity by varying its sizes. In the absence of cell samples inside the transmission line, the relative modulation of the electric and/or magnetic field was ±31% with respect to the mean values, allowing the processing of more samples at different exposure fields in a single run. A slight decrease in spontaneous mutability to rifampicin-resistance of the E. coli JC411 strain was demonstrated in mismatch-repair proficient samples exposed to the radio-frequency fields during their growth on solid medium.
Radio-frequency measurements of UNiX compounds (X=Al, Ga, Ge) in high magnetic fields
NASA Astrophysics Data System (ADS)
Alsmadi, A. M.; Alyones, S.; Mielke, C. H.; McDonald, R. D.; Zapf, V.; Altarawneh, M. M.; Lacerda, A.; Chang, S.; Adak, S.; Kothapalli, K.; Nakotte, H.
2009-11-01
We performed radio-frequency (RF) skin-depth measurements of antiferromagnetic UNiX compounds (X=Al, Ga, Ge) in magnetic fields up to 60 T and at temperatures between 1.4 to ~60 K. Magnetic fields are applied along different crystallographic directions and RF penetration-depth was measured using a tunnel-diode oscillator (TDO) circuit. The sample is coupled to the inductive element of a TDO resonant tank circuit, and the shift in the resonant frequency Δ f of the circuit is measured. The UNiX compounds exhibit field-induced magnetic transitions at low temperatures, and those transitions are accompanied by a drastic change in Δ f. The results of our skin-depth measurements were compared with previously published B- T phase diagrams for these three compounds.
Radiofrequency Electromagnetic Field Map of Timisoara
NASA Astrophysics Data System (ADS)
Stefu, N.; Solyom, I.; Arama, A.
2015-12-01
There are many electromagnetic field (EMF) sources nowadays acting simultaneously, especially in urban areas, making the theoretical estimation of electromagnetic power at ground level very difficult. This paper reports on EMF maps built with measurements collected in Timisoara, at various radiofrequencies. A grid of 15×15 squares was built (approximate resolution 400m x 400m) and measurements of the average and maximum values of the electric field E, magnetic field H and total power density S at 0.9, 1.8 and 2.4 GHz were collected in every node of the grid. Positions of the nodes in terms of latitude and longitude were also collected. Maps were built presenting the spatial distribution of the measured quantities over Timisoara. Potential influences of EMF on public health are discussed.
Non-Lethal Weapons The Use Radiofrequency/Microwave Energy for Stunning/Immobilization
2008-11-26
0.75 to 1 GHz RF fields on skeletal muscle contraction using fixed frequencies and just recently implementing frequency sweep paradigms; 4) initiation...This basic research initiative is geared ultimately toward developing effective and safe non-lethal technologies that alter skeletal muscle ... contraction and/or neural functioning via radiofrequency (RF)/microwave (MW) electromagnetic radiation. Major accomplishments included 1) near completion of
Shielding superconductors with thin films as applied to rf cavities for particle accelerators
Posen, Sam; Transtrum, Mark K.; Catelani, Gianluigi; ...
2015-10-29
Determining the optimal arrangement of superconducting layers to withstand large-amplitude ac magnetic fields is important for certain applications such as superconducting radio-frequency cavities. In this paper, we evaluate the shielding potential of the superconducting-film–insulating-film–superconductor (SIS') structure, a configuration that could provide benefits in screening large ac magnetic fields. After establishing that, for high-frequency magnetic fields, flux penetration must be avoided, the superheating field of the structure is calculated in the London limit both numerically and, for thin films, analytically. For intermediate film thicknesses and realistic material parameters, we also solve numerically the Ginzburg-Landau equations. As a result, it is shownmore » that a small enhancement of the superheating field is possible, on the order of a few percent, for the SIS' structure relative to a bulk superconductor of the film material, if the materials and thicknesses are chosen appropriately.« less
Langmuir probe measurements in the intense RF field of a helicon discharge
NASA Astrophysics Data System (ADS)
Chen, Francis F.
2012-10-01
Helicon discharges have extensively been studied for over 25 years both because of their intriguing physics and because of their utility in producing high plasma densities for industrial applications. Almost all measurements so far have been made away from the antenna region in the plasma ejected into a chamber where there may be a strong magnetic field (B-field) but where the radiofrequency (RF) field is much weaker than under the antenna. Inside the source region, the RF field distorts the current-voltage (I-V) characteristic of the probe unless it is specially designed with strong RF compensation. For this purpose, a thin probe was designed and used to show the effect of inadequate compensation on electron temperature (Te) measurements. The subtraction of ion current from the I-V curve is essential; and, surprisingly, Langmuir's orbital motion limited theory for ion current can be used well beyond its intended regime.
Percutaneous bipolar radiofrequency thermocoagulation for the treatment of lumbar disc herniation.
Zeng, Zhenhua; Yan, Min; Dai, Yi; Qiu, Weidong; Deng, Shuo; Gu, Xinzhu
2016-08-01
Lumbar disc herniation is usually managed with conservative treatment or surgery. However, conservative therapy seldom yields good results, and surgery is associated with multiple complications. This study aimed to assess bipolar radiofrequency thermocoagulation for the treatment of lumbar disc herniation. A total of 168 patients with lumbar disc herniation suitable for radiofrequency thermocoagulation were enrolled and randomized to monopolar radiofrequency thermocoagulation (control group, n=84) or bipolar radiofrequency thermocoagulation (experimental group, n=84) treatment groups. Ablation sites were targeted under CT scan guidance, and consecutive radiofrequency therapy was used. One and two probes were used for monopolar and bipolar thermocoagulation, respectively. Thermocoagulation was achieved at 50°C, 60°C, and 70°C for 60s each, 80°C for 90s, and 92°C for 100s. Symptoms and complications were evaluated using the modified Macnab criteria and Visual Analog Scale at 7, 30, and 180days postoperatively. At 180days, a significantly higher efficacy rate was obtained in the experimental group compared with control patients (91.6% versus 79.7%, P<0.05). No severe complications were occurred in either group. Targeted ablation via bipolar radiofrequency thermocoagulation is efficient for lumbar disc herniation treatment, and should be further explored for broad clinical application. Copyright © 2016 Elsevier Ltd. All rights reserved.
A diamond-based scanning probe spin sensor operating at low temperature in ultra-high vacuum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schaefer-Nolte, E.; Wrachtrup, J.; 3rd Institute of Physics and Research Center SCoPE, University Stuttgart, 70569 Stuttgart
2014-01-15
We present the design and performance of an ultra-high vacuum (UHV) low temperature scanning probe microscope employing the nitrogen-vacancy color center in diamond as an ultrasensitive magnetic field sensor. Using this center as an atomic-size scanning probe has enabled imaging of nanoscale magnetic fields and single spins under ambient conditions. In this article we describe an experimental setup to operate this sensor in a cryogenic UHV environment. This will extend the applicability to a variety of molecular systems due to the enhanced target spin lifetimes at low temperature and the controlled sample preparation under UHV conditions. The instrument combines amore » tuning-fork based atomic force microscope (AFM) with a high numeric aperture confocal microscope and the facilities for application of radio-frequency (RF) fields for spin manipulation. We verify a sample temperature of <50 K even for strong laser and RF excitation and demonstrate magnetic resonance imaging with a magnetic AFM tip.« less
New-generation radiofrequency technology.
Krueger, Nils; Sadick, Neil S
2013-01-01
Radiofrequency (RF) technology has become a standard treatment in aesthetic medicine with many indications due to its versatility, efficacy, and safety. It is used worldwide for cellulite reduction; acne scar revision; and treatment of hypertrophic scars and keloids, rosacea, and inflammatory acne in all skin types. However, the most common indication for RF technology is the nonablative tightening of tissue to improve skin laxity and reduce wrinkles. Radiofrequency devices are classified as unipolar, bipolar, or multipolar depending on the number of electrodes used. Additional modalities include fractional RF; sublative RF; phase-controlled RF; and combination RF therapies that apply light, massage, or pulsed electromagnetic fields (PEMFs). This article reviews studies and case series on these devices. Radiofrequency technology for aesthetic medicine has seen rapid advancements since it was used for skin tightening in 2003. Future developments will continue to keep RF technology at the forefront of the dermatologist's armamentarium for skin tightening and rejuvenation.
Simulation studies promote technological development of radiofrequency phased array hyperthermia.
Wust, P; Seebass, M; Nadobny, J; Deuflhard, P; Mönich, G; Felix, R
1996-01-01
A treatment planning program package for radiofrequency hyperthermia has been developed. It consists of software modules for processing three-dimensional computerized tomography (CT) data sets, manual segmentation, generation of tetrahedral grids, numerical calculation and optimisation of three-dimensional E field distributions using a volume surface integral equation algorithm as well as temperature distributions using an adaptive multilevel finite-elements code, and graphical tools for simultaneous representation of CT data and simulation results. Heat treatments are limited by hot spots in healthy tissues caused by E field maxima at electrical interfaces (bone/muscle). In order to reduce or avoid hot spots suitable objective functions are derived from power deposition patterns and temperature distributions, and are utilised to optimise antenna parameters (phases, amplitudes). The simulation and optimisation tools have been applied to estimate the improvements that could be reached by upgrades of the clinically used SIGMA-60 applicator (consisting of a single ring of four antenna pairs). The investigated upgrades are increased number of antennas and channels (triple-ring of 3 x 8 antennas and variation of antenna inclination. Significant improvement of index temperatures (1-2 degrees C) is achieved by upgrading the single ring to a triple ring with free phase selection for every antenna or antenna pair. Antenna amplitudes and inclinations proved as less important parameters.
NASA Astrophysics Data System (ADS)
Zajicek, J.; Burian, M.; Soukup, P.; Novak, V.; Macko, M.; Jakubek, J.
2017-01-01
Multimodal medical imaging based on Magnetic Resonance is mainly combinated with one of the scintigraphic method like PET or SPECT. These methods provide functional information whereas magnetic resonance imaging provides high spatial resolution of anatomical information or complementary functional information. Fusion of imaging modalities allows researchers to obtain complimentary information in a single measurement. The combination of MRI with SPECT is still relatively new and challenging in many ways. The main complication of using SPECT in MRI systems is the presence of a high magnetic field therefore (ferro)magnetic materials have to be eliminated. Furthermore the application of radiofrequency fields within the MR gantry does not allow for the use of conductive structures such as the common heavy metal collimators. This work presents design and construction of an experimental MRI-SPECT insert system and its initial tests. This unique insert system consists of an MR-compatible SPECT setup with CdTe pixelated sensors Timepix tungsten collimators and a radiofrequency coil. Measurements were performed on a gelatine and tissue phantom with an embedded radioisotopic source (57Co 122 keV γ ray) inside the RF coil by the Bruker BioSpec 47/20 (4.7 T) MR animal scanner. The project was performed in the framework of the Medipix Collaboration.
Extreme diffusion limited electropolishing of niobium radiofrequency cavities
Crawford, Anthony C.
2017-01-04
In this study, a deeply modulated, regular, continuous, oscillating current waveform is reliably and repeatably achieved during electropolishing of niobium single-cell elliptical radiofrequency cavities. Details of the technique and cavity test results are reported here. The method is applicable for cavity frequencies in the range 500 MHz to 3.9 GHz and can be extended to multicell structures.
Bunch, T Jared; Day, John D; Packer, Douglas L
2009-04-01
The approach to catheter-based radiofrequency ablation of atrial fibrillation has evolved, and as a consequence, more energy is delivered in the posterior left atrium, exposing neighboring tissue to untoward thermal injury. Simultaneously, catheter technology has advanced to allow more efficient energy delivery into the myocardium, which compounds the likelihood of collateral injury. This review focuses on the basic principles of thermodynamics as they apply to energy delivery during radiofrequency ablation. These principles can be used to titrate energy delivery and plan ablative approaches in an effort to minimize complications during the procedure.
Draft Environmental Impact Statement-Consolidated Space Operations Center.
1980-10-01
about 10 in the human resonance (worst case) region of the electromagnetic spectrum. The USAF has a significant Radiofrequency Radiation (RFR...accessis necessary. I 3. Restrict all air traffic within 1000 feet of the antenna - field to avoid possible exposure of electroexplosive de- vices to...Permissible Exposure Level (MPEL) for occupational personnel is 10 mw/cm 2 and is based on past knowledge of radiofrequency radiation effects (Ref
Demagnetization of a complete superconducting radiofrequency cryomodule: Theory and practice
Crawford, Anthony C.; Chandrasekaran, Saravan K.
2016-12-07
Here, a significant advance in magnetic field management in a fully assembled superconducting radiofrequency (SRF) cryomodule has been achieved and is reported here. Demagnetization of the entire cryomodule after assembly is a crucial step toward the goal of average magnetic flux density less than 0.5 μT at the location of the superconducting radio frequency cavities. An explanation of the physics of demagnetization and experimental results are presented.
Du, Bin; Han, Shuping; Li, Hongyan; Zhao, Feifei; Su, Xiangjie; Cao, Xiaohui; Zhang, Zhenzhong
2015-03-12
Recently, nanoplatforms with multiple functions, such as tumor-targeting drug carriers, MRI, optical imaging, thermal therapy etc., have become popular in the field of cancer research. The present study reports a novel multi-functional liposome for cancer theranostics. A dual targeted drug delivery with radiofrequency-triggered drug release and imaging based on the magnetic field influence was used advantageously for tumor multi-mechanism therapy. In this system, the surface of fullerene (C60) was decorated with iron oxide nanoparticles, and PEGylation formed a hybrid nanosystem (C60-Fe3O4-PEG2000). Thermosensitive liposomes (dipalmitoylphosphatidylcholine, DPPC) with DSPE-PEG2000-folate wrapped up the hybrid nanosystem and docetaxel (DTX), which were designed to combine features of biological and physical (magnetic) drug targeting for fullerene radiofrequency-triggered drug release. The magnetic liposomes not only served as powerful tumor diagnostic magnetic resonance imaging (MRI) contrast agents, but also as powerful agents for photothermal ablation of tumors. Furthermore, a remarkable thermal therapy combined chemotherapy multi-functional liposome nanoplatform converted radiofrequency energy into thermal energy to release drugs from thermosensitive liposomes, which was also observed during both in vitro and in vivo treatment. The multi-functional liposomes also could selectively kill cancer cells in highly localized regions via their excellent active tumor targeting and magnetic targeted abilities.
Starkey, Sarah J
2016-12-01
The Advisory Group on Non-ionising Radiation (AGNIR) 2012 report forms the basis of official advice on the safety of radiofrequency (RF) electromagnetic fields in the United Kingdom and has been relied upon by health protection agencies around the world. This review describes incorrect and misleading statements from within the report, omissions and conflict of interest, which make it unsuitable for health risk assessment. The executive summary and overall conclusions did not accurately reflect the scientific evidence available. Independence is needed from the International Commission on Non-Ionizing Radiation Protection (ICNIRP), the group that set the exposure guidelines being assessed. This conflict of interest critically needs to be addressed for the forthcoming World Health Organisation (WHO) Environmental Health Criteria Monograph on Radiofrequency Fields. Decision makers, organisations and individuals require accurate information about the safety of RF electromagnetic signals if they are to be able to fulfil their safeguarding responsibilities and protect those for whom they have legal responsibility.
Radio-frequency measurements of UNiX compounds (X= Al, Ga, Ge) in high magnetic fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mielke, Charles H; Mcdonald, David R; Zapf, Vivien
2009-01-01
We performed radio-frequency (RF) skin-depth measurements of antiferromagnetic UNiX compounds (X=Al, Ga, Ge) in magnetic fields up to 60 T and at temperatures between 1.4 to {approx}60 K. Magnetic fields are applied along different crystallographic directions and RF penetration-depth was measured using a tunnel-diode oscillator (TDO) circuit. The sample is coupled to the inductive element of a TDO resonant tank circuit, and the shift in the resonant frequency {Delta}f of the circuit is measured. The UNiX compounds exhibit field-induced magnetic transitions at low temperatures, and those transitions are accompanied by a drastic change in {Delta}f. The results of our skin-depthmore » measurements were compared with previously published B-T phase diagrams for these three compounds.« less
NASA Astrophysics Data System (ADS)
Passeri, Alessandro; Mazzuca, Stefano; Del Bene, Veronica
2014-06-01
Clinical magnetic resonance spectroscopy imaging (MRSI) is a non-invasive functional technique, whose mathematical framework falls into the category of linear inverse problems. However, its use in medical diagnostics is hampered by two main problems, both linked to the Fourier-based technique usually implemented for spectra reconstruction: poor spatial resolution and severe blurring in the spatial localization of the reconstructed spectra. Moreover, the intrinsic ill-posedness of the MRSI problem might be worsened by (i) spatially dependent distortions of the static magnetic field (B0) distribution, as well as by (ii) inhomogeneity in the power deposition distribution of the radiofrequency magnetic field (B1). Among several alternative methods, slim (Spectral Localization by IMaging) and bslim (B0 compensated slim) are reconstruction algorithms in which a priori information concerning the spectroscopic target is introduced into the reconstruction kernel. Nonetheless, the influence of the B1 field, particularly when its operating wavelength is close to the size of the human organs being studied, continues to be disregarded. starslim (STAtic and Radiofrequency-compensated slim), an evolution of the slim and bslim methods, is therefore proposed, in which the transformation kernel also includes the B1 field inhomogeneity map, thus allowing almost complete 3D modelling of the MRSI problem. Moreover, an original method for the experimental determination of the B1 field inhomogeneity map specific to the target under evaluation is also included. The compensation capabilities of the proposed method have been tested and illustrated using synthetic raw data reproducing the human brain.
Factors that influence the radiofrequency power output of GSM mobile phones.
Erdreich, Linda S; Van Kerkhove, Maria D; Scrafford, Carolyn G; Barraj, Leila; McNeely, Mark; Shum, Mona; Sheppard, Asher R; Kelsh, Michael
2007-08-01
Epidemiological studies of mobile phone use and risk of brain cancer have relied on self-reported use, years as a subscriber, and billing records as exposure surrogates without addressing the level of radiofrequency (RF) power output. The objective of this study was to measure environmental, behavioral and engineering factors affecting the RF power output of GSM mobile phones during operation. We estimated the RF-field exposure of volunteer subjects who made mobile phone calls using software-modified phones (SMPs) that recorded output power settings. Subjects recruited from three geographic areas in the U.S. were instructed to log information (place, time, etc.) for each call made and received during a 5-day period. The largest factor affecting energy output was study area, followed by user movement and location (inside or outside), use of a hands-free device, and urbanicity, although the two latter factors accounted for trivial parts of overall variance. Although some highly statistically significant differences were identified, the effects on average energy output rate were usually less than 50% and were generally comparable to the standard deviation. These results provide information applicable to improving the precision of exposure metrics for epidemiological studies of GSM mobile phones and may have broader application for other mobile phone systems and geographic locations.
Niendorf, Thoralf; Pohlmann, Andreas; Reimann, Henning M.; Waiczies, Helmar; Peper, Eva; Huelnhagen, Till; Seeliger, Erdmann; Schreiber, Adrian; Kettritz, Ralph; Strobel, Klaus; Ku, Min-Chi; Waiczies, Sonia
2015-01-01
Research in pathologies of the brain, heart and kidney have gained immensely from the plethora of studies that have helped shape new methods in magnetic resonance (MR) for characterizing preclinical disease models. Methodical probing into preclinical animal models by MR is invaluable since it allows a careful interpretation and extrapolation of data derived from these models to human disease. In this review we will focus on the applications of cryogenic radiofrequency (RF) coils in small animal MR as a means of boosting image quality (e.g., by supporting MR microscopy) and making data acquisition more efficient (e.g., by reducing measuring time); both being important constituents for thorough investigational studies on animal models of disease. This review attempts to make the (bio)medical imaging, molecular medicine, and pharmaceutical communities aware of this productive ferment and its outstanding significance for anatomical and functional MR in small rodents. The goal is to inspire a more intense interdisciplinary collaboration across the fields to further advance and progress non-invasive MR methods that ultimately support thorough (patho)physiological characterization of animal disease models. In this review, current and potential future applications for the RF coil technology in cardiovascular, neurovascular, and renal disease will be discussed. PMID:26617515
Pruttivarasin, Thaned; Katori, Hidetoshi
2015-11-01
We present a compact field-programmable gate array (FPGA) based pulse sequencer and radio-frequency (RF) generator suitable for experiments with cold trapped ions and atoms. The unit is capable of outputting a pulse sequence with at least 32 transistor-transistor logic (TTL) channels with a timing resolution of 40 ns and contains a built-in 100 MHz frequency counter for counting electrical pulses from a photo-multiplier tube. There are 16 independent direct-digital-synthesizers RF sources with fast (rise-time of ∼60 ns) amplitude switching and sub-mHz frequency tuning from 0 to 800 MHz.
Simulation of a Radio-Frequency Photogun for the Generation of Ultrashort Beams
NASA Astrophysics Data System (ADS)
Nikiforov, D. A.; Levichev, A. E.; Barnyakov, A. M.; Andrianov, A. V.; Samoilov, S. L.
2018-04-01
A radio-frequency photogun for the generation of ultrashort electron beams to be used in fast electron diffractoscopy, wakefield acceleration experiments, and the design of accelerating structures of the millimeter range is modeled. The beam parameters at the photogun output needed for each type of experiment are determined. The general outline of the photogun is given, its electrodynamic parameters are calculated, and the accelerating field distribution is obtained. The particle dynamics is analyzed in the context of the required output beam parameters. The optimal initial beam characteristics and field amplitudes are chosen. A conclusion is made regarding the obtained beam parameters.
Detection of NMR signals with a radio-frequency atomic magnetometer.
Savukov, I M; Seltzer, S J; Romalis, M V
2007-04-01
We demonstrate detection of proton NMR signals with a radio-frequency (rf) atomic magnetometer tuned to the NMR frequency of 62 kHz. High-frequency operation of the atomic magnetometer makes it relatively insensitive to ambient magnetic field noise. We obtain magnetic field sensitivity of 7 fT/Hz1/2 using only a thin aluminum shield. We also derive an expression for the fundamental sensitivity limit of a surface inductive pick-up coil as a function of frequency and find that an atomic rf magnetometer is intrinsically more sensitive than a coil of comparable size for frequencies below about 50 MHz.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pruttivarasin, Thaned, E-mail: thaned.pruttivarasin@riken.jp; Katori, Hidetoshi; Innovative Space-Time Project, ERATO, JST, Bunkyo-ku, Tokyo 113-8656
We present a compact field-programmable gate array (FPGA) based pulse sequencer and radio-frequency (RF) generator suitable for experiments with cold trapped ions and atoms. The unit is capable of outputting a pulse sequence with at least 32 transistor-transistor logic (TTL) channels with a timing resolution of 40 ns and contains a built-in 100 MHz frequency counter for counting electrical pulses from a photo-multiplier tube. There are 16 independent direct-digital-synthesizers RF sources with fast (rise-time of ∼60 ns) amplitude switching and sub-mHz frequency tuning from 0 to 800 MHz.
Zhao, Yujuan; Zhao, Tiejun; Raval, Shailesh B; Krishnamurthy, Narayanan; Zheng, Hai; Harris, Chad T; Handler, William B; Chronik, Blaine A; Ibrahim, Tamer S
2015-11-01
To optimize the design of radiofrequency (RF) shielding of transmit coils at 7T and reduce eddy currents generated on the RF shielding when imaging with rapid gradient waveforms. One set of a four-element, 2 × 2 Tic-Tac-Toe head coil structure was selected and constructed to study eddy currents on the RF coil shielding. The generated eddy currents were quantitatively studied in the time and frequency domains. The RF characteristics were studied using the finite difference time domain method. Five different kinds of RF shielding were tested on a 7T MRI scanner with phantoms and in vivo human subjects. The eddy current simulation method was verified by the measurement results. Eddy currents induced by solid/intact and simple-structured slotted RF shielding significantly distorted the gradient fields. Echo-planar images, B1+ maps, and S matrix measurements verified that the proposed slot pattern suppressed the eddy currents while maintaining the RF characteristics of the transmit coil. The presented dual-optimization method could be used to design RF shielding and reduce the gradient field-induced eddy currents while maintaining the RF characteristics of the transmit coil. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Kim, Byung Chan; Park, Seong-Ook
In order to determine exposure compliance with the electromagnetic fields from a base station's antenna in the far-field region, we should calculate the spatially averaged field value in a defined space. This value is calculated based on the measured value obtained at several points within the restricted space. According to the ICNIRP guidelines, at each point in the space, the reference levels are averaged over any 6min (from 100kHz to 10GHz) for the general public. Therefore, the more points we use, the longer the measurement time becomes. For practical application, it is very advantageous to spend less time for measurement. In this paper, we analyzed the difference of average values between 6min and lesser periods and compared it with the standard uncertainty for measurement drift. Based on the standard deviation from the 6min averaging value, the proposed minimum averaging time is 1min.
Fukushima, Eiichi; Roeder, Stephen B. W.; Assink, Roger A.; Gibson, Atholl A. V.
1986-01-01
An improved nuclear magnetic resonance (NMR) apparatus for use in topical magnetic resonance (TMR) spectroscopy and other remote sensing NMR applications includes a semitoroidal radio-frequency (rf) coil. The semitoroidal rf coil produces an effective alternating magnetic field at a distance from the poles of the coil, so as to enable NMR measurements to be taken from selected regions inside an object, particularly including human and other living subjects. The semitoroidal rf coil is relatively insensitive to magnetic interference from metallic objects located behind the coil, thereby rendering the coil particularly suited for use in both conventional and superconducting NMR magnets. The semitoroidal NMR coil can be constructed so that it emits little or no excess rf electric field associated with the rf magnetic field, thus avoiding adverse effects due to dielectric heating of the sample or to any other interaction of the electric field with the sample.
Numerical simulation of NQR/NMR: Applications in quantum computing.
Possa, Denimar; Gaudio, Anderson C; Freitas, Jair C C
2011-04-01
A numerical simulation program able to simulate nuclear quadrupole resonance (NQR) as well as nuclear magnetic resonance (NMR) experiments is presented, written using the Mathematica package, aiming especially applications in quantum computing. The program makes use of the interaction picture to compute the effect of the relevant nuclear spin interactions, without any assumption about the relative size of each interaction. This makes the program flexible and versatile, being useful in a wide range of experimental situations, going from NQR (at zero or under small applied magnetic field) to high-field NMR experiments. Some conditions specifically required for quantum computing applications are implemented in the program, such as the possibility of use of elliptically polarized radiofrequency and the inclusion of first- and second-order terms in the average Hamiltonian expansion. A number of examples dealing with simple NQR and quadrupole-perturbed NMR experiments are presented, along with the proposal of experiments to create quantum pseudopure states and logic gates using NQR. The program and the various application examples are freely available through the link http://www.profanderson.net/files/nmr_nqr.php. Copyright © 2011 Elsevier Inc. All rights reserved.
Elibol, Oguz H; Reddy, Bobby; Nair, Pradeep R; Dorvel, Brian; Butler, Felice; Ahsan, Zahab S; Bergstrom, Donald E; Alam, Muhammad A; Bashir, Rashid
2009-10-07
We demonstrate electrically addressable localized heating in fluid at the dielectric surface of silicon-on-insulator field-effect transistors via radio-frequency Joule heating of mobile ions in the Debye layer. Measurement of fluid temperatures in close vicinity to surfaces poses a challenge due to the localized nature of the temperature profile. To address this, we developed a localized thermometry technique based on the fluorescence decay rate of covalently attached fluorophores to extract the temperature within 2 nm of any oxide surface. We demonstrate precise spatial control of voltage dependent temperature profiles on the transistor surfaces. Our results introduce a new dimension to present sensing systems by enabling dual purpose silicon transistor-heaters that serve both as field effect sensors as well as temperature controllers that could perform localized bio-chemical reactions in Lab on Chip applications.
First muon acceleration using a radio-frequency accelerator
NASA Astrophysics Data System (ADS)
Bae, S.; Choi, H.; Choi, S.; Fukao, Y.; Futatsukawa, K.; Hasegawa, K.; Iijima, T.; Iinuma, H.; Ishida, K.; Kawamura, N.; Kim, B.; Kitamura, R.; Ko, H. S.; Kondo, Y.; Li, S.; Mibe, T.; Miyake, Y.; Morishita, T.; Nakazawa, Y.; Otani, M.; Razuvaev, G. P.; Saito, N.; Shimomura, K.; Sue, Y.; Won, E.; Yamazaki, T.
2018-05-01
Muons have been accelerated by using a radio-frequency accelerator for the first time. Negative muonium atoms (Mu- ), which are bound states of positive muons (μ+) and two electrons, are generated from μ+'s through the electron capture process in an aluminum degrader. The generated Mu- 's are initially electrostatically accelerated and injected into a radio-frequency quadrupole linac (RFQ). In the RFQ, the Mu- 's are accelerated to 89 keV. The accelerated Mu- 's are identified by momentum measurement and time of flight. This compact muon linac opens the door to various muon accelerator applications including particle physics measurements and the construction of a transmission muon microscope.
Experimental investigation of a metasurface resonator for in vivo imaging at 1.5 T
NASA Astrophysics Data System (ADS)
Shchelokova, Alena V.; Slobozhanyuk, Alexey P.; de Bruin, Paul; Zivkovic, Irena; Kallos, Efthymios; Belov, Pavel A.; Webb, Andrew
2018-01-01
In this work, we experimentally demonstrate an increase in the local transmit efficiency of a 1.5 T MRI scanner by using a metasurface formed by an array of brass wires embedded in a high permittivity low loss medium. Placement of such a structure inside the scanner results in strong coupling of the radiofrequency field produced by the body coil with the lowest frequency electromagnetic eigenmode of the metasurface. This leads to spatial redistribution of the near fields with enhancement of the local magnetic field and an increase in the transmit efficiency per square root maximum specific absorption rate in the region-of-interest. We have investigated this structure in vivo and achieved a factor of 3.3 enhancement in the local radiofrequency transmit efficiency.
NASA Astrophysics Data System (ADS)
Saiko, A. P.; Fedaruk, R.; Markevich, S. A.
2018-05-01
The decay of Rabi oscillations provides direct information about coherence of electron spins. When observed in EPR experiments, it is often shortened by spatial inhomogeneity of the microwave field amplitude in a bulk sample. In order to suppress this undesired loss of coherence, we propose an additional dressing of spin states by a weak longitudinal continuous radiofrequency field. The Gaussian, cosine and linear distributions of the microwave amplitude is analyzed. Our calculations of the Rabi oscillations between the doubly dressed spin states show that for all these distributions the maximum suppression of the inhomogeneity-induced decoherence is achieved at the so-called Rabi resonance when the radio-field frequency is in resonance with the Rabi frequency of spins in the microwave field. The manifestations of such suppression in the published EPR experiments with the bichromatic driving are discussed. The realization of the Rabi resonance using the radiofrequency field could open new possibilities for separating the contributions of relaxation mechanisms from those due to the inhomogeneous driving in spin decoherence.
External unit for a semi-implantable middle ear hearing device.
Garverick, S L; Kane, M; Ko, W H; Maniglia, A J
1997-06-01
A miniaturized, low-power external unit has been developed for the clinical trials of a semi-implantable middle ear electromagnetic hearing device (SIMEHD) which uses radio-frequency telemetry to couple sound signals to the internal unit. The external unit is based on a commercial hearing aid which provides proven audio amplification and compression. Its receiver is replaced by an application-specific integrated circuit (ASIC) which: 1) adjusts the direct-current bias of the audio input according to its peak value; 2) converts the audio signal to a one-bit digital form using sigma-delta modulation; 3) modulates the sigma-delta output with a radio-frequency (RF) oscillator; and 4) drives the external RF coil and tuning capacitor using a field-effect transistor operated in class D. The external unit functions as expected and has been used to operate bench-top tests to the SIMEHD. Measured current consumption is 1.65-2.15 mA, which projects to a battery lifetime of about 15 days. Bandwidth is 6 kHz and harmonic distortion is about 2%.
Seror, O
2015-06-01
Several ablation techniques are currently available. Except for electroporation, all of these methods cause fatal damage at a cellular level and irreversible architectural deconstruction at a tissue level by thermal effects. Ablation of a tumor using one of these techniques, whether thermal or otherwise, requires applicators to be positioned from which the energy is delivered in situ. Some techniques, however, require several applicators to be inserted (multibipolar radiofrequency, cryotherapy and electroporation) whereas a single applicator is often sufficient with other technologies (monopolar radiofrequency and microwave). These methods are conceptually very similar but are distinguished from each other in practice through the technologies they use. It is essential to understand these differences as they influence the advantages and limitations of each of the techniques. There is no such thing as the perfect multifunctional ablation device and choice is dictated on an individual patient basis depending on the aim of treatment, which itself depends on each patient's clinical situation. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Measurements of Euglena motion parameters by laser light scattering.
Ascoli, C; Barbi, M; Frediani, C; Murè, A
1978-01-01
Measurements of Euglena gracilis motion parameters have been performed by the spectral analysis of the scattered laser light. Samples were oriented by a radiofrequency field to obtain easily interpretable spectra. Cell rotation frequency and flagellar beating frequency distributions were obtained from the homodyne spectra, whereas the Doppler lines obtained at small observation angles by heterodyne detection yielded the swimming speed distributions. We discuss the broadening of the heterodyne spectra at large angles of observation. An application of this method to the study of the photo-kinetic effect is also described. Images FIGURE 3 PMID:104747
IRIDE: Interdisciplinary research infrastructure based on dual electron linacs and lasers
NASA Astrophysics Data System (ADS)
Ferrario, M.; Alesini, D.; Alessandroni, M.; Anania, M. P.; Andreas, S.; Angelone, M.; Arcovito, A.; Arnesano, F.; Artioli, M.; Avaldi, L.; Babusci, D.; Bacci, A.; Balerna, A.; Bartalucci, S.; Bedogni, R.; Bellaveglia, M.; Bencivenga, F.; Benfatto, M.; Biedron, S.; Bocci, V.; Bolognesi, M.; Bolognesi, P.; Boni, R.; Bonifacio, R.; Boscherini, F.; Boscolo, M.; Bossi, F.; Broggi, F.; Buonomo, B.; Calo, V.; Catone, D.; Capogni, M.; Capone, M.; Cassou, K.; Castellano, M.; Castoldi, A.; Catani, L.; Cavoto, G.; Cherubini, N.; Chirico, G.; Cestelli-Guidi, M.; Chiadroni, E.; Chiarella, V.; Cianchi, A.; Cianci, M.; Cimino, R.; Ciocci, F.; Clozza, A.; Collini, M.; Colo, G.; Compagno, A.; Contini, G.; Coreno, M.; Cucini, R.; Curceanu, C.; Curciarello, F.; Dabagov, S.; Dainese, E.; Davoli, I.; Dattoli, G.; De Caro, L.; De Felice, P.; De Leo, V.; Dell Agnello, S.; Della Longa, S.; Delle Monache, G.; De Spirito, M.; Di Cicco, A.; Di Donato, C.; Di Gioacchino, D.; Di Giovenale, D.; Di Palma, E.; Di Pirro, G.; Dodaro, A.; Doria, A.; Dosselli, U.; Drago, A.; Dupraz, K.; Escribano, R.; Esposito, A.; Faccini, R.; Ferrari, A.; Filabozzi, A.; Filippetto, D.; Fiori, F.; Frasciello, O.; Fulgentini, L.; Gallerano, G. P.; Gallo, A.; Gambaccini, M.; Gatti, C.; Gatti, G.; Gauzzi, P.; Ghigo, A.; Ghiringhelli, G.; Giannessi, L.; Giardina, G.; Giannini, C.; Giorgianni, F.; Giovenale, E.; Giulietti, D.; Gizzi, L.; Guaraldo, C.; Guazzoni, C.; Gunnella, R.; Hatada, K.; Iannone, M.; Ivashyn, S.; Jegerlehner, F.; Keeffe, P. O.; Kluge, W.; Kupsc, A.; Labate, L.; Levi Sandri, P.; Lombardi, V.; Londrillo, P.; Loreti, S.; Lorusso, A.; Losacco, M.; Lukin, A.; Lupi, S.; Macchi, A.; Magazù, S.; Mandaglio, G.; Marcelli, A.; Margutti, G.; Mariani, C.; Mariani, P.; Marzo, G.; Masciovecchio, C.; Masjuan, P.; Mattioli, M.; Mazzitelli, G.; Merenkov, N. P.; Michelato, P.; Migliardo, F.; Migliorati, M.; Milardi, C.; Milotti, E.; Milton, S.; Minicozzi, V.; Mobilio, S.; Morante, S.; Moricciani, D.; Mostacci, A.; Muccifora, V.; Murtas, F.; Musumeci, P.; Nguyen, F.; Orecchini, A.; Organtini, G.; Ottaviani, P. L.; Pace, C.; Pace, E.; Paci, M.; Pagani, C.; Pagnutti, S.; Palmieri, V.; Palumbo, L.; Panaccione, G. C.; Papadopoulos, C. F.; Papi, M.; Passera, M.; Pasquini, L.; Pedio, M.; Perrone, A.; Petralia, A.; Petrarca, M.; Petrillo, C.; Petrillo, V.; Pierini, P.; Pietropaolo, A.; Pillon, M.; Polosa, A. D.; Pompili, R.; Portoles, J.; Prosperi, T.; Quaresima, C.; Quintieri, L.; Rau, J. V.; Reconditi, M.; Ricci, A.; Ricci, R.; Ricciardi, G.; Ricco, G.; Ripani, M.; Ripiccini, E.; Romeo, S.; Ronsivalle, C.; Rosato, N.; Rosenzweig, J. B.; Rossi, A. A.; Rossi, A. R.; Rossi, F.; Rossi, G.; Russo, D.; Sabatucci, A.; Sabia, E.; Sacchetti, F.; Salducco, S.; Sannibale, F.; Sarri, G.; Scopigno, T.; Sekutowicz, J.; Serafini, L.; Sertore, D.; Shekhovtsova, O.; Spassovsky, I.; Spadaro, T.; Spataro, B.; Spinozzi, F.; Stecchi, A.; Stellato, F.; Surrenti, V.; Tenore, A.; Torre, A.; Trentadue, L.; Turchini, S.; Vaccarezza, C.; Vacchi, A.; Valente, P.; Venanzoni, G.; Vescovi, S.; Villa, F.; Zanotti, G.; Zema, N.; Zobov, M.; Zomer, F.
2014-03-01
This paper describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity "particles factory", based on a combination of high duty cycle radio-frequency superconducting electron linacs and of high energy lasers. Conceived to provide unique research possibilities for particle physics, for condensed matter physics, chemistry and material science, for structural biology and industrial applications, IRIDE will open completely new research possibilities and advance our knowledge in many branches of science and technology. IRIDE is also supposed to be realized in subsequent stages of development depending on the assigned priorities.
Radio frequency multicusp ion source development (invited)
NASA Astrophysics Data System (ADS)
Leung, K. N.
1996-03-01
The radio-frequency (rf) driven multicusp source was originally developed for use in the Superconducting Super Collider injector. It has been demonstrated that the source can meet the H- beam current and emittance requirements for this application. By employing a porcelain-coated antenna, a clean plasma discharge with very long-life operation can be achieved. Today, the rf source is used to generate both positive and negative hydrogen ion beams and has been tested in various particle accelerator laboratories throughout the world. Applications of this ion source have been extended to other fields such as ion beam lithography, oil-well logging, ion implantation, accelerator mass spectrometry and medical therapy machines. This paper summarizes the latest rf ion source technology and development at the Lawrence Berkeley National Laboratory.
Fractional kinetics of glioma treatment by a radio-frequency electric field
NASA Astrophysics Data System (ADS)
Iomin, A.
2013-09-01
A realistic model for estimation of the medical effect of brain cancer (glioma) treatment by a radio-frequency (RF) electric field is suggested. This low intensity, intermediate-frequency alternating electric field is known as the tumor-treating field (TTF). The model is based on a construction of 3D comb model for a description of the cancer cells dynamics, where the migration-proliferation dichotomy becomes naturally apparent, and the outer-invasive region of glioma cancer is considered as a fractal composite embedded in the 3D space. In the framework of this model, the interplay between the TTF and the migration-proliferation dichotomy of cancer cells is considered, and the efficiency of this TTF is estimated. It is shown that the efficiency of the medical treatment by the TTF depends essentially on the mass fractal dimension of the cancer in the outer-invasive region.
Nanoparticle mediated ablation of breast cancer cells using a nanosecond pulsed electric field
NASA Astrophysics Data System (ADS)
Burford, Christopher
In the past, both nanomaterials and various heating modalities have been researched as means for treating cancers. However, many of the current methodologies have the flaws of inconsistent tumor ablation and significant destruction of healthy cells. Based on research performed using constant radiofrequency electric fields and metallic nanoparticles (where cell necrosis is induced by the heating of these nanoparticles) we have developed a modality that simlarly uses functionalized metallic nanoparticles, specific for the T47D breast cancer cell line, and nanosecond pulsed electric fields as the hyperthermic inducer. Using both iron oxide and gold nanoparticles the results of our pilot studies indicated that up to 90% of the cancer cells were ablated given the optimal treatment parameters. These quantities of ablated cells were achieved using a cumulative exposure time 6 orders of magnitude less than most in vitro radiofrequency electric field studies.
Inductively guided circuits for ultracold dressed atoms
Sinuco-León, German A.; Burrows, Kathryn A.; Arnold, Aidan S.; Garraway, Barry M.
2014-01-01
Recent progress in optics, atomic physics and material science has paved the way to study quantum effects in ultracold atomic alkali gases confined to non-trivial geometries. Multiply connected traps for cold atoms can be prepared by combining inhomogeneous distributions of DC and radio-frequency electromagnetic fields with optical fields that require complex systems for frequency control and stabilization. Here we propose a flexible and robust scheme that creates closed quasi-one-dimensional guides for ultracold atoms through the ‘dressing’ of hyperfine sublevels of the atomic ground state, where the dressing field is spatially modulated by inductive effects over a micro-engineered conducting loop. Remarkably, for commonly used atomic species (for example, 7Li and 87Rb), the guide operation relies entirely on controlling static and low-frequency fields in the regimes of radio-frequency and microwave frequencies. This novel trapping scheme can be implemented with current technology for micro-fabrication and electronic control. PMID:25348163
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao, Yu; Che, Yuchi; Zhou, Chongwu, E-mail: chongwuz@usc.edu
In this paper, we report the high-performance radio-frequency transistors based on the single-walled semiconducting carbon nanotubes with a refined average diameter of ∼1.6 nm. These diameter-separated carbon nanotube transistors show excellent transconductance of 55 μS/μm and desirable drain current saturation with an output resistance of ∼100 KΩ μm. An exceptional radio-frequency performance is also achieved with current gain and power gain cut-off frequencies of 23 GHz and 20 GHz (extrinsic) and 65 GHz and 35 GHz (intrinsic), respectively. These radio-frequency metrics are among the highest reported for the carbon nanotube thin-film transistors. This study provides demonstration of radio frequency transistors based on carbon nanotubes with tailoredmore » diameter distributions, which will guide the future application of carbon nanotubes in radio-frequency electronics.« less
A unique complication of radiofrequency therapy to the tongue base
Tornari, Chrysostomos; Wong, Gentle; Arora, Asit; Kotecha, Bhik
2015-01-01
Introduction Radiofrequency ablation treatment of the tongue base can be used either alone or as part of a multilevel approach in the treatment of snoring. This involves the generation of thermal energy around the circumvallate papillae of the tongue. Potential complications include ulceration, dysphagia, haematoma and abscess formation. Presentation of case We present the case of a 50-year-old patient who developed an anterior neck swelling following a second application of radiofrequency ablation therapy to the tongue base for snoring. This was secondary to an infection of a previously undiagnosed thyroglossal cyst. The patient made a full recovery following intravenous antibiotic therapy and ultrasound-guided needle aspiration. Discussion Thyroglossal tract remnants are thought to be present in seven percent of the adult population. An infection in a thyroglossal tract cyst has not previously been reported following radiofrequency ablation of the tongue base. Given the relatively high complication rate of tongue base radiofrequency ablation in some series, this complication may be under-recognised. Conclusion An infected thyroglossal tract cyst should be suspected in patients with anterior neck swellings following radiofrequency ablation therapy to the tongue base. We advise caution when performing this procedure on patients with known thyroglossal tract remnants though there is insufficient evidence to suggest that this procedure is contraindicated. PMID:25603484
Radiofrequency for the treatment of skin laxity: mith or truth*
de Araújo, Angélica Rodrigues; Soares, Viviane Pinheiro Campos; da Silva, Fernanda Souza; Moreira, Tatiane da Silva
2015-01-01
The nonablative radiofrequency is a procedure commonly used for the treatment of skin laxity from an increase in tissue temperature. The goal is to induce thermal damage to thus stimulate neocollagenesis in deep layers of the skin and subcutaneous tissue. However, many of these devices haven't been tested and their parameters are still not accepted by the scientific community. Because of this, it is necessary to review the literature regarding the physiological effects and parameters for application of radiofrequency and methodological quality and level of evidence of studies. A literature search was performed in MEDLINE, PEDro, SciELO, PubMed, LILACS and CAPES and experimental studies in humans, which used radiofrequency devices as treatment for facial or body laxity, were selected. The results showed that the main physiological effect is to stimulate collagen synthesis. There was no homogeneity between studies in relation to most of the parameters used and the methodological quality of studies and level of evidence for using radiofrequency are low. This fact complicates the determination of effective parameters for clinical use of this device in the treatment of skin laxity. The analyzed studies suggest that radiofrequency is effective, however the physiological mechanisms and the required parameters are not clear in the literature. PMID:26560216
A far-field radio-frequency experimental exposure system with unrestrained mice.
Hansen, Jared W; Asif, Sajid; Singelmann, Lauren; Khan, Muhammad Saeed; Ghosh, Sumit; Gustad, Tom; Doetkott, Curt; Braaten, Benjamin D; Ewert, Daniel L
2015-01-01
Many studies have been performed on exploring the effects of radio-frequency (RF) energy on biological function in vivo. In particular, gene expression results have been inconclusive due, in part, to a lack of a standardized experimental procedure. This research describes a new far field RF exposure system for unrestrained murine models that reduces experimental error. The experimental procedure includes the materials used, the creation of a patch antenna, the uncertainty analysis of the equipment, characterization of the test room, experimental equipment used and setup, power density and specific absorption rate experiment, and discussion. The result of this research is an experimental exposure system to be applied to future biological studies.
Remotely Triggered Cisplatin Release from Carbon Nanocapsules by Radiofrequency Fields
Raoof, Mustafa; Cisneros, Brandon T.; Guven, Adem; Corr, Stuart J.; Wilson, Lon J.; Curley, Steven A.
2013-01-01
The efficacy of nanoparticle-mediated drug delivery is limited by its peri-vascular sequestration, thus necessitating a strategy to trigger drug release from such intra-tumoral nanocarrier-drug depots. In our efforts to explore remotely-activated nanocarriers, we have developed carbon nanocapsules comprised of an ultrashort carbon nanotube shell (US-tubes) loaded with cisplatin (CDDP@US-tubes) and covered with a Pluronic surfactant wrapping to minimize passive release. We demonstrate here that non-invasive radiofrequency (RF) field activation of the CDDP@US-tubes produces heat that causes Pluronic disruption which triggers cisplatin release in an RF-dependent manner. Furthermore, release-dependent cytotoxicity is demonstrated in human hepatocellular carcinoma cell lines. PMID:23228421
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-01
... of Exposure to Radiofrequency Electromagnetic Fields Limits and Policies AGENCY: Federal... Electromagnetic Fields Limits and Policies, ET Docket Nos. 03-137 and 13-84; FCC 13-39. The date for filing reply...
Belenky, Inna; Margulis, Ariel; Elman, Monica; Bar-Yosef, Udi; Paun, Silviu D
2012-03-01
Because of its high efficiency and safety, radiofrequency (RF) energy is widely used in the dermatological field for heating biological tissue in various esthetic applications, including skin tightening, skin lifting, body contouring, and cellulite reduction. This paper reviews the literature on the use of nonablative RF energy in the esthetic field and its scientific background. The purpose of this article is to describe in detail the extensive use of medical devices based on RF technology, the development of these medical devices over the years, and recent developments and trends in RF technology. The authors conducted a systematic search of publications that address safety and efficacy issues, technical system specifications, and clinical techniques. Finally, the authors focused on their own clinical experiences with the use of patented Channeling Optimized RF Energy technique and mechanical massage. An in-vivo study was conducted in domestic pigs, with a thermal video camera. Twenty-seven female patients participated in a cellulite and body shaping study. The treatments were conducted according to a three-phase protocol. An additional 16 females participated in a skin tightening case study. All of the patients underwent three treatment sessions at 3-week intervals, each according to a protocol specific to the area being treated. The review of the literature on RF-based systems revealed that these systems are safe, with low risks for potential side effects, and effective for cellulite, body contouring, and skin tightening procedures. The in-vivo measurements confirmed the theory that the penetration depth of RF is an inverse function of its frequency, and using a vacuum mechanism makes an additional contribution to the RF energy penetration. The heating effect of RF was also found to increase blood circulation and to induce collagen remodeling. The results from the cellulite and body shaping treatments showed an overall average improvement of 55% in the appearance of cellulite, with an average circumferential reduction of 3.31 cm in the buttocks, 2.94 cm in the thighs, and 2.14 cm in the abdomen. The results from the skin tightening procedure showed moderate improvement of skin appearance in 50% and significant improvement in 31%. At the follow-up visits the results were found to be sustained without any significant side effects. Of all tissue heating techniques, RF-based technologies appear to be the most established and clinically proven. The design and specifications of the described vacuumassisted bipolar RF device fall within the range of the specifications currently prescribed for esthetic, nonablative RF systems.
Experimental investigation of a metasurface resonator for in vivo imaging at 1.5 T.
Shchelokova, Alena V; Slobozhanyuk, Alexey P; de Bruin, Paul; Zivkovic, Irena; Kallos, Efthymios; Belov, Pavel A; Webb, Andrew
2018-01-01
In this work, we experimentally demonstrate an increase in the local transmit efficiency of a 1.5 T MRI scanner by using a metasurface formed by an array of brass wires embedded in a high permittivity low loss medium. Placement of such a structure inside the scanner results in strong coupling of the radiofrequency field produced by the body coil with the lowest frequency electromagnetic eigenmode of the metasurface. This leads to spatial redistribution of the near fields with enhancement of the local magnetic field and an increase in the transmit efficiency per square root maximum specific absorption rate in the region-of-interest. We have investigated this structure in vivo and achieved a factor of 3.3 enhancement in the local radiofrequency transmit efficiency. Copyright © 2017 Elsevier Inc. All rights reserved.
Bortone, Agustín; Brault-Noble, Guillaume; Appetiti, Anthony; Marijon, Eloi
2015-08-01
It has been experimentally shown that elimination of the negative component of the unipolar atrial electrogram (R morphology completion) during radiofrequency applications reflects transmural lesions creation. Subsequently, it has been clinically suggested that such a transmurality can be either irreversible or reversible. The present study is aimed to determine, at the histological level, whether transmural lesions, assessed by R morphology completion, might indeed be reversible in some circumstances or not. In 6 Mongrel hound dogs, superior and inferior vena cavae were isolated and individual lesions were created in the right atrium using radiofrequency energy (30 W/48°C/17 mL/min as presettings and 10g of force in average) under CARTO guidance. Five types of lesions were created; R+0: termination of ablation at the time of R morphology completion; R+5, R+10, or R+20: extension of ablation for 5, 10, or 20 seconds, respectively, after R morphology achievement; and conventional: radiofrequency applications lasting 30 seconds irrespective of the atrial electrogram modification. All conventional, R+5, R+10, and R+20 lesions were necrotic and transmural, whereas some R+0 lesions were not (comprising a part of necrosis and a part of reversible cell damage). Interestingly, surrounding organ injuries were observed after conventional, R+10, and R+20 radiofrequency applications but were not observed after R+0 and R+5 applications. Elimination of the negative component of the unipolar atrial electrogram reflects, in general, irreversible transmural necrosis creation. In some cases, however, it translates transmural lesion only (with potential reversibility) likely related to transient cell damage creation. © 2015 American Heart Association, Inc.
Lee, Jeong Min; Choi, Seong Hong; Park, Hee Seon; Lee, Min Woo; Han, Chang Jin; Choi, Joon-il; Choi, Ja-Young; Hong, Sung Hwan; Han, Joon Koo; Choi, Byung Ihn
2005-09-01
Our purposes were to determine whether a single application of radiofrequency energy to normal bone can create coagulation necrosis reproducibly and to assess the accuracy of MRI at revealing the extent of radiofrequency-induced thermal bone injury. Using a 200-W generator and a 17-gauge cooled-tip electrode, a total of 11 radiofrequency ablations were performed under fluoroscopic guidance in the distal femurs of seven dogs. Radiofrequency was applied in standard monopolar mode at 100 W for 10 min. During radiofrequency ablation, the changes in impedance and currents were recorded. MRI, including unenhanced T1- and T2-weighted images and contrast-enhanced fat-suppressed T1-weighted images, was performed to evaluate ablation regions. Six dogs were killed on day 4 after MRI and one dog on day 7. In all animals, radiofrequency ablation created a well-defined coagulation necrosis and no significant complications were noted. The mean long-axis diameter and the mean short-axis diameter of the coagulation zones produced were 45.9 +/- 5.5 mm and 17.7 +/- 2.7 mm, respectively. At gross examination, thermal ablation regions appeared as a central, light-brown area with a dark-brown peripheral hemorrhagic zone, which was surrounded by a pale-yellow rim. On MRI, the ablated areas showed multilayered zones with signal intensities that differed from normal marrow on unenhanced images and a perfusion defect on contrast-enhanced T1-weighted images. The maximum difference between lesion sizes on MR images, established by measuring macroscopic coagulation necrosis, was 3 mm. The correlation between the diameter of coagulation necrosis and lesion size at MRI was strong, with correlation coefficients ranging from 0.89 for unenhanced T1-weighted images and 0.97 for unenhanced T2-weighted images to 0.98 for contrast-enhanced T1-weighted images (p < 0.05). Radiofrequency ablation created well-defined coagulation necrosis in a reproducible manner, and MRI accurately determined the extent of the radiofrequency-induced thermal bone injury.
Mateos, José Carlos Pachón; Mateos, Enrique I Pachón; Peña, Tomas G Santillana; Lobo, Tasso Julio; Mateos, Juán Carlos Pachón; Vargas, Remy Nelson A; Pachón, Carlos Thiene C; Acosta, Juán Carlos Zerpa
2015-01-01
Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8 ± 14 [17-84] years old), with mean EF of 0.66 ± 0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. The mean esophageal displacement was 4 to 9.1cm (5.9 ± 0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11 ± 0.13ºC versus 1.1 ± 0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most cases, the esophageal displacement was sufficient to allow safe radiofrequency application without esophagus overlapping, being a convenient alternative in reducing the risk of atrioesophageal fistula.
Kumar, Santosh; Fan, Haoquan; Kübler, Harald; Jahangiri, Akbar J; Shaffer, James P
2017-04-17
Rydberg atom-based electrometry enables traceable electric field measurements with high sensitivity over a large frequency range, from gigahertz to terahertz. Such measurements are particularly useful for the calibration of radio frequency and terahertz devices, as well as other applications like near field imaging of electric fields. We utilize frequency modulated spectroscopy with active control of residual amplitude modulation to improve the signal to noise ratio of the optical readout of Rydberg atom-based radio frequency electrometry. Matched filtering of the signal is also implemented. Although we have reached similarly, high sensitivity with other read-out methods, frequency modulated spectroscopy is advantageous because it is well-suited for building a compact, portable sensor. In the current experiment, ∼3 µV cm-1 Hz-1/2 sensitivity is achieved and is found to be photon shot noise limited.
Elibol, Oguz H.; Reddy, Bobby; Nair, Pradeep R.; Dorvel, Brian; Butler, Felice; Ahsan, Zahab; Bergstrom, Donald E.; Alam, Muhammad A.; Bashir, Rashid
2010-01-01
We demonstrate electrically addressable localized heating in fluid at the dielectric surface of silicon-on-insulator field-effect transistors via radio-frequency Joule heating of mobile ions in the Debye layer. Measurement of fluid temperatures in close vicinity to surfaces poses a challenge due to the localized nature of the temperature profile. To address this, we developed a localized thermometry technique based on the fluorescence decay rate of covalently attached fluorophores to extract the temperature within 2 nm of any oxide surface. We demonstrate precise spatial control of voltage dependent temperature profiles on the transistor surfaces. Our results introduce a new dimension to present sensing systems by enabling dual purpose silicon transistor-heaters that serve both as field effect sensors as well as temperature controllers that could perform localized bio-chemical reactions in Lab on Chip applications. PMID:19967115
Design of an interventional magnetic resonance imaging coil for cerebral surgery
NASA Astrophysics Data System (ADS)
Xu, Yue; Wang, Wen-Tao; Wang, Wei-Min
2012-11-01
In clinical magnetic resonance imaging (MRI), the design of the radiofrequency (RF) coil is very important. For certain applications, the appropriate coil can produce an improved image quality. However, it is difficult to achieve a uniform B1 field and a high signal-to-noise ratio (SNR) simultaneously. In this article, we design an interventional transmitter-and-receiver RF coil for cerebral surgery. This coil adopts a disassembly structure that can be assembled and disassembled repeatedly on the cerebral surgery gantry to reduce the amount of interference from the MRI during surgery. The simulation results and the imaging experiments demonstrate that this coil can produce a uniform RF field, a high SNR, and a large imaging range to meet the requirements of the cerebral surgery.
Electromagnetic Emission from Electric Propulsions under Ground Conditions
NASA Astrophysics Data System (ADS)
Baranov, S. V.; Vazhenin, N. A.; Plokhikh, A. P.; Popov, G. A.
2017-12-01
Analysis and methodological generalization of available methods used for determining characteristics of intrinsic emission from electric propulsions (EP) in a radio-frequency range that can be the interference for the "Earth-spacecraft (SC)" channel of the space communication system are the subjects of this paper. Intrinsic emission from the electric propulsion in a radio-frequency range is examined in detail by the example of a measuring complex developed in RIAME MAI and the measurement results are presented. The electric field intensity distribution in a radio-frequency range for the vertical and horizontal polarizations of the received emission is considered as the main characteristics. Measurements performed for the EP intrinsic emission by using the developed complex and measurements performed in metal vacuum chambers are compared and comparative results are presented in the paper.
NASA Astrophysics Data System (ADS)
Goldberg, S. Nahum; Gazelle, G. Scott
1998-04-01
Radiofrequency (RF) tumor ablation has been demonstrated as a reliable method for creating thermally induced coagulation necrosis using either a percutaneous approach with image- guidance or direct surgical application of thin electrodes into treated tissues. Early clinical trials with this technology have studied the treatment of hepatic, cerebral, and bony malignancies. The extent of coagulation necrosis induced with conventional monopolar radiofrequency electrodes is dependent on overall energy deposition, the duration of RF application, and RF electrode tip length and gauge. This article will discuss these technical considerations with the goal of defining optimal parameters for RF ablation. Strategies to further increase induced coagulation necrosis including: multiprobe and bipolar arrays, and internally-cooled RF electrodes, with or without pulsed-RF or cluster technique will be presented. The development and laboratory results for many of these radiofrequency techniques, initial clinical results, and potential biophysical limitations to RF induced coagulation, such as perfusion mediated tissue cooling (vascular flow) will likewise be discussed.
Gryz, Krzysztof; Karpowicz, Jolanta; Leszko, Wiesław; Zradziński, Patryk
2014-12-01
The aim of the study was to identify and assess electromagnetic radiofrequency radiation (EMRR) exposure in a workplace located in a publicly accessible environment, and represented by offices (where exposure is caused by various transmitters of local fixed indoor and outdoor wireless communication systems). The investigations were performed in 45 buildings (in urban and rural areas in various regions of Poland), using frequency-selective electric field strength (E-field) exposimeters sensitive to the EMRR with a frequency range of 88-2500 MHz, split into 12 sub-bands corresponding to the operating frequencies of typical EMRR sources. The variability of the E-field was analyzed for each frequency range and the total level of exposure by statistical parameters of recorded exposimetric profiles: minimum, maximum, median values and 25-75th - percentiles. The main sources of exposure to EMRR are mobile phone base transceiver stations (BTS) and radio-television transmitters (RTV). The frequency composition in a particular office depends on the building's location. The E-field recorded in buildings in urban and rural areas from the outdoor BTS did not exceed respectively: medians - 0.19 and 0.05 V/m, 75th percentiles -0.25 and 0.09 V/m. In buildings equipped with the indoor BTS antennas the E-field did not exceed: medians - 1 V/m, 75th percentiles - 1.8 V/m. Whereas in urban and rural areas, the median and 75th percentile values of the E-field recorded in buildings located near the RTV (within 1 km) did not exceed: 1.5 and 3.8 V/m or 0.4 and 0.8 V/m, for radio FM band or for TV bands, respectively. Investigations confirmed the practical applicability of the exposimetric measurements technique for evaluating parameters of worker's exposure in both frequency- and time-domain. The presented results show EMRR exposure of workers or general public in locations comparable to offices to be well below international limits.
Occupational exposure to electromagnetic fields from medical sources
STAM, Rianne; YAMAGUCHI-SEKINO, Sachiko
2017-01-01
High exposures to electromagnetic fields (EMF) can occur near certain medical devices in the hospital environment. A systematic assessment of medical occupational EMF exposure could help to clarify where more attention to occupational safety may be needed. This paper seeks to identify sources of high exposure for hospital workers and compare the published exposure data to occupational limits in the European Union. A systematic search for peer-reviewed publications was conducted via PubMed and Scopus databases. Relevant grey literature was collected via a web search. For each publication, the highest measured magnetic flux density or internal electric field strength per device and main frequency component was extracted. For low frequency fields, high action levels may be exceeded for magnetic stimulation, MRI gradient fields and movement in MRI static fields. For radiofrequency fields, the action levels may be exceeded near devices for diathermy, electrosurgery and hyperthermia and in the radiofrequency field inside MRI scanners. The exposure limit values for internal electric field may be exceeded for MRI and magnetic stimulation. For MRI and magnetic stimulation, practical measures can limit worker exposure. For diathermy, electrosurgery and hyperthermia, additional calculations are necessary to determine if SAR limits may be exceeded in some scenarios. PMID:29109357
Visualizing radiofrequency-skin interaction using multiphoton microscopy in vivo.
Tsai, Tsung-Hua; Lin, Sung-Jan; Lee, Woan-Ruoh; Wang, Chun-Chin; Hsu, Chih-Ting; Chu, Thomas; Dong, Chen-Yuan
2012-02-01
Redundant skin laxity is a major feature of aging. Recently, radiofrequency has been introduced for nonablative tissue tightening by volumetric heating of the deep dermis. Despite the wide range of application based on this therapy, the effect of this technique on tissue and the subsequent tissue remodeling have not been investigated in detail. Our objective is to evaluate the potential of non-linear optics, including multiphoton autofluorescence and second harmonic generation (SHG) microscopy, as a non-invasive imaging modality for the real-time study of radiofrequency-tissue interaction. Electro-optical synergy device (ELOS) was used as the radiofrequency source in this study. The back skin of nude mouse was irradiated with radiofrequency at different passes. We evaluated the effect on skin immediately and 1 month after treatment with multiphoton microscopy. Corresponding histology was performed for comparison. We found that SHG is negatively correlated to radiofrequency passes, which means that collagen structural disruption happens immediately after thermal damage. After 1 month of collagen remodeling, SHG signals increased above baseline, indicating that collagen regeneration has occurred. Our findings may explain mechanism of nonablative skin tightening and were supported by histological examinations. Our work showed that monitoring the dermal heating status of RF and following up the detailed process of tissue reaction can be imaged and quantified with multiphoton microscopy non-invasively in vivo. Copyright © 2011. Published by Elsevier Ireland Ltd.
Trapped Ion Oscillation Frequencies as Sensors for Spectroscopy
Vogel, Manuel; Quint, Wolfgang; Nörtershäuser, Wilfried
2010-01-01
The oscillation frequencies of charged particles in a Penning trap can serve as sensors for spectroscopy when additional field components are introduced to the magnetic and electric fields used for confinement. The presence of so-called “magnetic bottles” and specific electric anharmonicities creates calculable energy-dependences of the oscillation frequencies in the radiofrequency domain which may be used to detect the absorption or emission of photons both in the microwave and optical frequency domains. The precise electronic measurement of these oscillation frequencies therefore represents an optical sensor for spectroscopy. We discuss possible applications for precision laser and microwave spectroscopy and their role in the determination of magnetic moments and excited state life-times. Also, the trap-assisted measurement of radiative nuclear de-excitations in the X-ray domain is discussed. This way, the different applications range over more than 12 orders of magnitude in the detectable photon energies, from below μeV in the microwave domain to beyond MeV in the X-ray domain. PMID:22294921
Symmetry-breaking inelastic wave-mixing atomic magnetometry.
Zhou, Feng; Zhu, Chengjie J; Hagley, Edward W; Deng, Lu
2017-12-01
The nonlinear magneto-optical rotation (NMOR) effect has prolific applications ranging from precision mapping of Earth's magnetic field to biomagnetic sensing. Studies on collisional spin relaxation effects have led to ultrahigh magnetic field sensitivities using a single-beam Λ scheme with state-of-the-art magnetic shielding/compensation techniques. However, the NMOR effect in this widely used single-beam Λ scheme is peculiarly small, requiring complex radio-frequency phase-locking protocols. We show the presence of a previously unknown energy symmetry-based nonlinear propagation blockade and demonstrate an optical inelastic wave-mixing NMOR technique that breaks this NMOR blockade, resulting in an NMOR optical signal-to-noise ratio (SNR) enhancement of more than two orders of magnitude never before seen with the single-beam Λ scheme. The large SNR enhancement was achieved simultaneously with a nearly two orders of magnitude reduction in laser power while preserving the magnetic resonance linewidth. This new method may open a myriad of applications ranging from biomagnetic imaging to precision measurement of the magnetic properties of subatomic particles.
Application of active quenching of second generation wire for current limiting
Solovyov, Vyacheslav F.; Li, Qiang
2015-10-19
Superconducting fault current limiters (SFCL's) are increasingly implemented in the power grid as a protection of substation equipment from fault currents. Resistive SFCL's are compact and light, however they are passively triggered and thus may not be sufficiently sensitive to respond to faults in the distribution grid. Here, we explore the prospect of adding an active management feature to a traditional resistive SFCL. A flexible radio-frequency coil, which is an integral part of the switching structure, acts as a triggering device. We show that the application of a short, 10 ms, burst of ac magnetic field during the fault triggersmore » a uniform quench of the wire and significantly reduces the reaction time of the wire at low currents. The ac field burst generates a high density of normal zones, which merge into a continuous resistive region at a rate much faster than that of sparse normal zones created by the transport current alone.« less
Magnetic Resonance Based Electrical Properties Tomography: A Review
Zhang, Xiaotong; Liu, Jiaen
2014-01-01
Frequency-dependent electrical properties (EPs; conductivity and permittivity) of biological tissues provide important diagnostic information (e.g. tumor characterization), and also play an important role in quantifying radiofrequency (RF) coil induced Specific Absorption Rate (SAR) which is a major safety concern in high- and ultrahigh-field Magnetic Resonance Imaging (MRI) applications. Cross-sectional imaging of EPs has been pursued for decades. Recently introduced Electrical Properties Tomography (EPT) approaches utilize the measurable RF magnetic field induced by the RF coil in an MRI system to quantitatively reconstruct the EP distribution in vivo and non-invasively with a spatial resolution of a few millimeters or less. This paper reviews the Electrical Properties Tomography approach from its basic theory in electromagnetism to the state of the art research outcomes. Emphasizing on the imaging reconstruction methods rather than experimentation techniques, we review the developed imaging algorithms, validation results in physical phantoms and biological tissues, as well as their applications in in vivo tumor detection and subject-specific SAR prediction. Challenges for future research are also discussed. PMID:24803104
Symmetry-breaking inelastic wave-mixing atomic magnetometry
Zhou, Feng; Zhu, Chengjie J.; Hagley, Edward W.; Deng, Lu
2017-01-01
The nonlinear magneto-optical rotation (NMOR) effect has prolific applications ranging from precision mapping of Earth’s magnetic field to biomagnetic sensing. Studies on collisional spin relaxation effects have led to ultrahigh magnetic field sensitivities using a single-beam Λ scheme with state-of-the-art magnetic shielding/compensation techniques. However, the NMOR effect in this widely used single-beam Λ scheme is peculiarly small, requiring complex radio-frequency phase-locking protocols. We show the presence of a previously unknown energy symmetry–based nonlinear propagation blockade and demonstrate an optical inelastic wave-mixing NMOR technique that breaks this NMOR blockade, resulting in an NMOR optical signal-to-noise ratio (SNR) enhancement of more than two orders of magnitude never before seen with the single-beam Λ scheme. The large SNR enhancement was achieved simultaneously with a nearly two orders of magnitude reduction in laser power while preserving the magnetic resonance linewidth. This new method may open a myriad of applications ranging from biomagnetic imaging to precision measurement of the magnetic properties of subatomic particles. PMID:29214217
Cohen-Mazor, Meital; Mathur, Prabodh; Stanley, James R.L.; Mendelsohn, Farrell O.; Lee, Henry; Baird, Rose; Zani, Brett G.; Markham, Peter M.; Rocha-Singh, Krishna
2014-01-01
Objective: To evaluate the safety and effectiveness of different bipolar radiofrequency system algorithms in interrupting the renal sympathetic nerves and reducing renal norepinephrine in a healthy porcine model. Methods: A porcine model (N = 46) was used to investigate renal norepinephrine levels and changes to renal artery tissues and nerves following percutaneous renal denervation with radiofrequency bipolar electrodes mounted on a balloon catheter. Parameters of the radiofrequency system (i.e. electrode length and energy delivery algorithm), and the effects of single and longitudinal treatments along the artery were studied with a 7-day model in which swine received unilateral radiofrequency treatments. Additional sets of animals were used to examine norepinephrine and histological changes 28 days following bilateral percutaneous radiofrequency treatment or surgical denervation; untreated swine were used for comparison of renal norepinephrine levels. Results: Seven days postprocedure, norepinephrine concentrations decreased proportionally to electrode length, with 81, 60 and 38% reductions (vs. contralateral control) using 16, 4 and 2-mm electrodes, respectively. Applying a temperature-control algorithm with the 4-mm electrodes increased efficacy, with a mean 89.5% norepinephrine reduction following a 30-s treatment at 68°C. Applying this treatment along the entire artery length affected more nerves vs. a single treatment, resulting in superior norepinephrine reduction 28 days following bilateral treatment. Conclusion: Percutaneous renal artery application of bipolar radiofrequency energy demonstrated safety and resulted in a significant renal norepinephrine content reduction and renal nerve injury compared with untreated controls in porcine models. PMID:24875181
Kaliada, T V; Vishnevskiĭ, A M; Gorodetskiĭ, B N; Plekhanov, V P; Kuznetsov, A V
2014-01-01
The authors present research findings on the problem of technology-related electromagnetic fields as an occupational risk factor of workers health disturbances, and on the issue of prevention measures development against this adverse physical factor effects. Prospects for further research development in the field of electromagnetic safety are discussed.
Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majdalany, Bill S., E-mail: bmajdala@med.umich.edu; Elliott, Eric D., E-mail: eric.elliott@osumc.edu; Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu
Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.
NASA Astrophysics Data System (ADS)
Ba, Nuo; Zhong, Xin; Wang, Lei; Fei, Jin-You; Zhang, Yan; Bao, Qian-Qian; Xiao, Li
2018-03-01
We investigate photonic transport properties of the 1D moving optical lattices filled with vast cold atoms driven into a four-level ladder-type system and obtain dynamically controlled photonic bandgaps and optical nonreciprocity. It is found that the two obvious optical nonreciprocity can be generated at two well-developed photonic bandgaps based on double dark states in the presence of a radio-frequency field. However, when the radio-frequency field is absence, the only one induced photonic bandgaps with distinguishing optical nonreciprocity can be opened up via single dark state. Dynamic control of the induced photonic bandgaps and optical nonreciprocity could be exploited to achieve all-optical diodes and routing for quantum information networks.
Radio-frequency power-assisted performance improvement of a magnetohydrodynamic power generator
NASA Astrophysics Data System (ADS)
Murakami, Tomoyuki; Okuno, Yoshihiro; Yamasaki, Hiroyuki
2005-12-01
We describe a radio-frequency (rf) electromagnetic-field-assisted magnetohydrodynamic power generation experiment, where an inductively coupled rf field (13.56MHz, 5.2kW) is continuously supplied to the disk generator. The rf power assists the precise plasma ignition, by which the otherwise irregular plasma behavior was stabilized. The rf heating suppresses the ionization instability in the plasma behavior and homogenizes the nonuniformity of the plasma structures. The power-generating performance is significantly improved with the aid of the rf power under wide seeding conditions: insufficient, optimum, and excessive seed fractions. The increment of the enthalpy extraction ratio of around 2% is significantly greater than the fraction of the net rf power, that is, 0.16%, to the thermal input.
7T: Physics, safety, and potential clinical applications.
Kraff, Oliver; Quick, Harald H
2017-12-01
With more than 60 installed magnetic resonance imaging (MRI) systems worldwide operating at a magnetic field strength of 7T or higher, ultrahigh-field (UHF) MRI has been established as a platform for clinically oriented research in recent years. Profound technical and methodological developments have helped overcome the inherent physical challenges of UHF radiofrequency (RF) signal homogenization in the human body. The ongoing development of dedicated RF coil arrays was pivotal in realizing UHF body MRI, beyond mere brain imaging applications. Another precondition to clinical application of 7T MRI is the safety testing of implants and the establishment of safety concepts. Against this backdrop, 7T MRI and MR spectroscopy (MRS) recently have demonstrated capabilities and potentials for clinical diagnostics in a variety of studies. This article provides an overview of the immanent physical challenges of 7T UHF MRI and discusses recent technical solutions and safety concepts. Furthermore, recent clinically oriented studies are highlighted that span a broad application spectrum from 7T UHF brain to body MRI. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1573-1589. © 2017 International Society for Magnetic Resonance in Medicine.
Recent progress in n-channel organic thin-film transistors.
Wen, Yugeng; Liu, Yunqi
2010-03-26
Particular attention has been focused on n-channel organic thin-film transistors (OTFTs) during the last few years, and the potentially cost-effective circuitry-based applications in flexible electronics, such as flexible radiofrequency identity tags, smart labels, and simple displays, will benefit from this fast development. This article reviews recent progress in performance and molecular design of n-channel semiconductors in the past five years, and limitations and practicable solutions for n-channel OTFTs are dealt with from the viewpoint of OTFT constitution and geometry, molecular design, and thin-film growth conditions. Strategy methodology is especially highlighted with an aim to investigate basic issues in this field.
FIBER AND INTEGRATED OPTICS: Radio-frequency electrooptic modulation in optical fibers
NASA Astrophysics Data System (ADS)
Bulyuk, A. N.
1992-10-01
The electrooptic interaction in single-mode optical fibers with both linear and circular birefringe is analyzed. In most cases, a large interaction length imposes a limit on the modulation frequency. A circular birefringence in an optical fiber may lead to an effective coupling of polarization normal modes if a phase-matching condition is satisfied. Through an appropriate choice of polarization states of the light at the entrance and exit of the device, one can achieve a polarization modulation or a frequency shift of the light. There are possible applications in rf polarization modulators, devices for shifting the frequency of light, and detectors of electromagnetic fields.
Human brain imaging at 9.4 T using a tunable patch antenna for transmission.
Hoffmann, Jens; Shajan, G; Budde, Juliane; Scheffler, Klaus; Pohmann, Rolf
2013-05-01
For human brain imaging at ultrahigh fields, the traveling wave concept can provide a more uniform B1+ field over a larger field of view with improved patient comfort compared to conventional volume coils. It suffers, however, from limited transmit efficiency and receive sensitivity and is not readily applicable in systems where the radiofrequency shield is too narrow to allow for unattenuated wave propagation. Here, the near field of a capacitively adjustable patch antenna for excitation is combined with a receive-only array at 9.4 T. The antenna is designed in compact size and placed in close proximity to the subject to improve the transmit efficiency in narrow bores. Experimental and numerical comparisons to conventional microstrip arrays reveal improved B1+ homogeneity and longitudinal coverage, but at the cost of elevated local specific absorption rate. High-resolution functional and anatomical images demonstrate the use of this setup for in vivo human brain imaging at 9.4 T. Copyright © 2012 Wiley Periodicals, Inc.
Bao, Guzhi; Wickenbrock, Arne; Rochester, Simon; Zhang, Weiping; Budker, Dmitry
2018-01-19
The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in phase with the precessing magnetization. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with ∼100 Hz width in the Earth-field range into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of the sensor within a range of orientation angles. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude, decreasing its width, and removing the important and limiting heading-error systematic.
Water-soluble core/shell nanoparticles for proton therapy through particle-induced radiation
NASA Astrophysics Data System (ADS)
Park, Jeong Chan; Jung, Myung-Hwan; Kim, Maeng Jun; Kim, Kye-Ryung
2015-02-01
Metallic nanoparticles have been used in biomedical applications such as magnetic resonance imaging (MRI), therapy, and drug delivery systems. Metallic nanoparticles as therapeutic tools have been demonstrated using radio-frequency magnetic fields or near-infrared light. Recently, therapeutic applications of metallic nanomaterials combined with proton beams have been reported. Particle-induced radiation from metallic nanoparticles, which can enhance the therapeutic effects of proton therapy, was released when the nanoparticles were bombarded by a high-energy proton beam. Core/shell nanoparticles, especially Au-coated magnetic nanoparticles, have drawn attention in biological applications due to their attractive characteristics. However, studies on the phase transfer of organic-ligand-based core/shell nanoparticles into water are limited. Herein, we demonstrated that hydrophobic core/shell structured nanomaterials could be successfully dispersed in water through chloroform/surfactant mixtures. The effects of the core/shell nanomaterials and the proton irradiation on Escherichia coli (E. coli) were also explored.
Dhakal, Pashupati; Ciovati, Gianluigi
2017-11-22
Here, we present the results of rf measurements on a niobium–copper clad superconducting radio-frequency cavity with different cooldown conditions and residual magnetic field in a vertical test Dewar in order to explore the effect of thermal current induced magnetic field and its trapping on the performance of the cavity. The residual resistance, extracted from the Q 0( T) curves in the temperature range 4.3–1.5 K, showed no dependence on a temperature gradient along the cavity during the cooldown across the critical temperature up to ~50 K m –1. The rf losses due to the trapping of residual magnetic field duringmore » the cavity cooldown were found to be ~4.3 nΩ μT –1, comparable to the values measured in bulk niobium cavities. An increase of residual resistance following multiple cavity quenches was observed along with evidence of trapping of magnetic flux generated by thermoelectric currents.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhakal, Pashupati; Ciovati, Gianluigi
Here, we present the results of rf measurements on a niobium–copper clad superconducting radio-frequency cavity with different cooldown conditions and residual magnetic field in a vertical test Dewar in order to explore the effect of thermal current induced magnetic field and its trapping on the performance of the cavity. The residual resistance, extracted from the Q 0( T) curves in the temperature range 4.3–1.5 K, showed no dependence on a temperature gradient along the cavity during the cooldown across the critical temperature up to ~50 K m –1. The rf losses due to the trapping of residual magnetic field duringmore » the cavity cooldown were found to be ~4.3 nΩ μT –1, comparable to the values measured in bulk niobium cavities. An increase of residual resistance following multiple cavity quenches was observed along with evidence of trapping of magnetic flux generated by thermoelectric currents.« less
SIDON: A simulator of radio-frequency networks. Application to WEST ICRF launchers
NASA Astrophysics Data System (ADS)
Helou, Walid; Dumortier, Pierre; Durodié, Frédéric; Goniche, Marc; Hillairet, Julien; Mollard, Patrick; Berger-By, Gilles; Bernard, Jean-Michel; Colas, Laurent; Lombard, Gilles; Maggiora, Riccardo; Magne, Roland; Milanesio, Daniele; Moreau, Didier
2015-12-01
SIDON (SImulator of raDiO-frequency Networks) is an in-house developed Radio-Frequency (RF) network solver that has been implemented to cross-validate the design of WEST ICRF launchers and simulate their impedance matching algorithm while considering all mutual couplings and asymmetries. In this paper, the authors illustrate the theory of SIDON as well as results of its calculations. The authors have built time-varying plasma scenarios (a sequence of launchers front-faces L-mode and H-mode Z-matrices), where at each time step (1 millisecond here), SIDON solves the RF network. At the same time, when activated, the impedance matching algorithm controls the matching elements (vacuum capacitors) and thus their corresponding S-matrices. Typically a 1-second pulse requires around 10 seconds of computational time on a desktop computer. These tasks can be hardly handled by commercial RF software. This innovative work allows identifying strategies for the launchers future operation while insuring the limitations on the currents, voltages and electric fields, matching and Load-Resilience, as well as the required straps voltage amplitude/phase balance. In this paper, a particular attention is paid to the simulation of the launchers behavior when arcs appear at several locations of their circuits using SIDON calculator. This latter work shall confirm or identify strategies for the arc detection using various RF electrical signals. One shall note that the use of such solvers in not limited to ICRF launchers simulations but can be employed, in principle, to any linear or linearized RF problem.
Thermal Ablation for Benign Thyroid Nodules: Radiofrequency and Laser
Lee, Jeong Hyun; Valcavi, Roberto; Pacella, Claudio M.; Rhim, Hyunchul; Na, Dong Gyu
2011-01-01
Although ethanol ablation has been successfully used to treat cystic thyroid nodules, this procedure is less effective when the thyroid nodules are solid. Radiofrequency (RF) ablation, a newer procedure used to treat malignant liver tumors, has been valuable in the treatment of benign thyroid nodules regardless of the extent of the solid component. This article reviews the basic physics, techniques, applications, results, and complications of thyroid RF ablation, in comparison to laser ablation. PMID:21927553
Boltzmann expansion in a radiofrequency conical helicon thruster operating in xenon and argon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charles, C.; Boswell, R.; Takahashi, K.
2013-06-03
A low pressure ({approx}0.5 mTorr in xenon and {approx}1 mTorr in argon) Boltzmann expansion is experimentally observed on axis within a magnetized (60 to 180 G) radiofrequency (13.56 MHz) conical helicon thruster for input powers up to 900 W using plasma parameters measured with a Langmuir probe. The axial forces, respectively, resulting from the electron and magnetic field pressures are directly measured using a thrust balance for constant maximum plasma pressure and show a higher fuel efficiency for argon compared to xenon.
"Cooking the sample": radiofrequency induced heating during solid-state NMR experiments.
d'Espinose de Lacaillerie, Jean-Baptiste; Jarry, Benjamin; Pascui, Ovidiu; Reichert, Detlef
2005-09-01
Dissipation of radiofrequency (RF) energy as heat during continuous wave decoupling in solid-state NMR experiment was examined outside the conventional realm of such phenomena. A significant temperature increase could occur while performing dynamic NMR measurements provided the sample contains polar molecules and the sequence calls for relatively long applications of RF power. It was shown that the methyl flip motion in dimethylsulfone (DMS) is activated by the decoupling RF energy conversion to heat during a CODEX pulse sequence. This introduced a significant bias in the correlation time-temperature dependency measurement used to obtain the activation energy of the motion. By investigating the dependency of the temperature increase in hydrated lead nitrate on experimental parameters during high-power decoupling one-pulse experiments, the mechanisms for the RF energy deposition was identified. The samples were heated due to dissipation of the energy absorbed by dielectric losses, a phenomenon commonly known as "microwave" heating. It was thus established that during solid-state NMR experiments at moderate B0 fields, RF heating could lead to the heating of samples containing polar molecules such as hydrated polymers and inorganic solids. In particular, this could result in systematic errors for slow dynamics measurements by solid-state NMR.
Koyama, Shin; Narita, Eijiro; Suzuki, Yoshihisa; Taki, Masao; Shinohara, Naoki; Miyakoshi, Junji
2015-01-01
The potential public health risks of radiofrequency (RF) fields have been discussed at length, especially with the use of mobile phones spreading extensively throughout the world. In order to investigate the properties of RF fields, we examined the effect of 2.45-GHz RF fields at the specific absorption rate (SAR) of 2 and 10 W/kg for 4 and 24 h on neutrophil chemotaxis and phagocytosis in differentiated human HL-60 cells. Neutrophil chemotaxis was not affected by RF-field exposure, and subsequent phagocytosis was not affected either compared with that under sham exposure conditions. These studies demonstrated an initial immune response in the human body exposed to 2.45-GHz RF fields at the SAR of 2 W/kg, which is the maximum value recommended by the International Commission for Non-Ionizing Radiation Protection (ICNIRP) guidelines. The results of our experiments for RF-field exposure at an SAR under 10 W/kg showed very little or no effects on either chemotaxis or phagocytosis in neutrophil-like human HL-60 cells. © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.
Gold, Michael H; Biesman, Brian S; Taylor, Mark
2017-06-01
Fractional bipolar radiofrequency treatment and treatment with bipolar radiofrequency combined with infrared light have been shown in previous trials to safely and effectively improve the appearance of facial wrinkles. To evaluate a high-energy protocol with combined bipolar radiofrequency and infrared light energies for improvement in photoaged facial skin. Seventy-two patients presenting with mild to moderate facial wrinkles underwent a single full-face treatment (n=54) or two treatments (n=18) at 6-week intervals. Independent blinded assessment and investigator assessment were performed, using the Fitzpatrick Wrinkle and Elastosis Scale (0-9) and the Global Aesthetic Improvement scale. Patients also completed a self-assessment questionnaire concerning satisfaction with the treatment. All patients achieved some degree of improvement in their wrinkles and skin appearance, following a single treatment or two treatments with the enhanced-energy protocol. Blinded evaluation demonstrated 71% and 70% of the patients showing improvement of one unit or greater on the Fitzpatrick Scale, at the 12-week and 24-week follow-ups post-treatment, respectively. Similar results were reported by investigators. Under the Global Aesthetic Improvement Scale, investigators observed 87%, 91% and 81% of patients showing improvement at the 6-, 12-, and 24-week post-treatment end, respectively. Patients tolerated the treatments well and were satisfied with the clinical results. The enhanced-energy treatment protocol, with fractional bipolar radiofrequency treatment and treatment with bipolar radiofrequency combined with infrared light applications, yields significant improvement of skin texture, wrinkling, and overall appearance following a single treatment. The results appear gradually over time and are maintained for at least 6 months' post-treatment. © 2017 Wiley Periodicals, Inc.
Kumaran, Binoy; Watson, Tim
2015-01-01
Radiofrequency-based electrophysical agents are widely used in therapy-related clinical practice for their thermal effects, mainly relieving pain and inflammation and improving tissue extensibility. The most commonly used and researched are shortwave therapies that operate at 27.12 MHz. Although relatively new, electrophysical agents employing much lower frequencies have also emerged. Capacitive resistive monopolar radiofrequency employing 448 kHz is one such therapy. This laboratory-based study was aimed to investigate the skin thermal responses to 448 kHz radiofrequency-based therapy in healthy adults. In a two-group randomised crossover study, 15 volunteers attended two modes (capacitive and resistive) of 448 kHz radiofrequency-based therapy (using 'Indiba Activ 902') administered locally to the lower thigh region. Starting at minimum, the intensity was increased incrementally until thermal discomfort was felt. Participants reported three time points: thermal onset, definite thermal sensation, and onset of thermal discomfort. Local skin temperature was measured before, immediately post-treatment and up to 45 min post-treatment. Both capacitive and resistive modes of therapy significantly increased the skin temperature and sustained it over the 45-min follow-up. There was statistically significant difference between the thermal response patterns produced by the two modes. Peak post-treatment temperatures attained were not significantly different between the two; however, the retention rate at follow-up was significantly higher for the resistive mode. This study confirms that radiofrequency-based therapy at 448 kHz can significantly increase and sustain skin temperature. The study also provides useful baseline data for further research in the low frequency ranges of radiofrequency-based therapy that remain largely unexplored.
DOE Office of Scientific and Technical Information (OSTI.GOV)
A.L. Roquemore; S.S. Medley
1998-01-01
The Charge Exchange Neutral Analyzer diagnostic for the Tokamak Fusion Test Reactor was designed to measure the energy distributions of both the thermal ions and the supra thermal populations arising from neutral-beam injection and ion cyclotron radio-frequency heating. These measurements yield the plasma ion temperature, as well as several other plasma parameters necessary to provide an understanding of the plasma condition and the performance of the auxiliary heating methods. For this application, a novel charge-exchange spectrometer using a dee-shaped region of parallel electric and magnetic fields was developed at the Princeton Plasma Physics Laboratory. The design and performance of thismore » spectrometer is described in detail, including the effects of exposure of the microchannel plate detector to magnetic fields, neutrons, and tritium.« less
NASA Astrophysics Data System (ADS)
Nagornykh, Pavel; Coppock, Joyce E.; Murphy, Jacob P. J.; Kane, B. E.
2017-07-01
Using optical measurements, we demonstrate that the rotation of micron-scale graphene nanoplatelets levitated in a quadrupole ion trap in high vacuum can be frequency-locked to an applied radiofrequency electric field Erf. Over time, frequency-locking stabilizes the nanoplatelet so that its axis of rotation is normal to the nanoplatelet and perpendicular to Erf. We observe that residual slow dynamics of the direction of the axis of rotation in the plane normal to Erf is determined by an applied magnetic field. We present a simple model that accurately describes our observations. From our data and model, we can infer both a diamagnetic polarizability and a magnetic moment proportional to the frequency of rotation, which we compare to theoretical values. Our results establish that trapping technologies have applications for materials measurements at the nanoscale.
NASA Astrophysics Data System (ADS)
Junginger, T.; Abidi, S. H.; Maffett, R. D.; Buck, T.; Dehn, M. H.; Gheidi, S.; Kiefl, R.; Kolb, P.; Storey, D.; Thoeng, E.; Wasserman, W.; Laxdal, R. E.
2018-03-01
The performance of superconducting radiofrequency (SRF) cavities used for particle accelerators depends on two characteristic material parameters: field of first flux entry Hentry and pinning strength. The former sets the limit for the maximum achievable accelerating gradient, while the latter determines how efficiently flux can be expelled related to the maximum achievable quality factor. In this paper, a method based on muon spin rotation (μ SR ) is developed to probe these parameters on samples. It combines measurements from two different spectrometers, one being specifically built for these studies and samples of different geometries. It is found that annealing at 1400 °C virtually eliminates all pinning. Such an annealed substrate is ideally suited to measure Hentry of layered superconductors, which might enable accelerating gradients beyond bulk niobium technology.
Aguirre, Erik; Iturri, Peio Lopez; Azpilicueta, Leire; de Miguel-Bilbao, Silvia; Ramos, Victoria; Gárate, Uxue; Falcone, Francisco
2015-03-01
A high number of wireless technologies can be found operating in vehicular environments with the aim of offering different services. The dosimetric evaluation of this kind of scenarios must be performed in order to assess their compatibility with current exposure limits. In this work, a dosimetric evaluation inside a conventional car is performed, with the aid of an in-house 3D Ray Launching computational code, which has been compared with measurement results of wireless sensor networks located inside the vehicle. These results can aid in an adequate assessment of human exposure to non-ionizing radiofrequency fields, taking into account the impact of the morphology and the topology of the vehicle for current as well as for future exposure limits.
Mateos, José Carlos Pachón; Mateos, Enrique I Pachón; Peña, Tomas G Santillana; Lobo, Tasso Julio; Mateos, Juán Carlos Pachón; Vargas, Remy Nelson A; Pachón, Carlos Thiene C; Acosta, Juán Carlos Zerpa
2015-01-01
Introduction Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. Objective This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Methods Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8±14 [17-84] years old), with mean EF of 0.66±0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. Results The mean esophageal displacement was 4 to 9.1cm (5.9±0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11±0.13ºC versus 1.1±0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. Conclusion Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most cases, the esophageal displacement was sufficient to allow safe radiofrequency application without esophagus overlapping, being a convenient alternative in reducing the risk of atrioesophageal fistula. PMID:26107444
Optical Trapping of Ion Coulomb Crystals
NASA Astrophysics Data System (ADS)
Schmidt, Julian; Lambrecht, Alexander; Weckesser, Pascal; Debatin, Markus; Karpa, Leon; Schaetz, Tobias
2018-04-01
The electronic and motional degrees of freedom of trapped ions can be controlled and coherently coupled on the level of individual quanta. Assembling complex quantum systems ion by ion while keeping this unique level of control remains a challenging task. For many applications, linear chains of ions in conventional traps are ideally suited to address this problem. However, driven motion due to the magnetic or radio-frequency electric trapping fields sometimes limits the performance in one dimension and severely affects the extension to higher-dimensional systems. Here, we report on the trapping of multiple barium ions in a single-beam optical dipole trap without radio-frequency or additional magnetic fields. We study the persistence of order in ensembles of up to six ions within the optical trap, measure their temperature, and conclude that the ions form a linear chain, commonly called a one-dimensional Coulomb crystal. As a proof-of-concept demonstration, we access the collective motion and perform spectrometry of the normal modes in the optical trap. Our system provides a platform that is free of driven motion and combines advantages of optical trapping, such as state-dependent confinement and nanoscale potentials, with the desirable properties of crystals of trapped ions, such as long-range interactions featuring collective motion. Starting with small numbers of ions, it has been proposed that these properties would allow the experimental study of many-body physics and the onset of structural quantum phase transitions between one- and two-dimensional crystals.
A statistical model of the wave field in a bounded domain
NASA Astrophysics Data System (ADS)
Hellsten, T.
2017-02-01
Numerical simulations of plasma heating with radiofrequency waves often require repetitive calculations of wave fields as the plasma evolves. To enable effective simulations, bench marked formulas of the power deposition have been developed. Here, a statistical model applicable to waves with short wavelengths is presented, which gives the expected amplitude of the wave field as a superposition of four wave fields with weight coefficients depending on the single pass damping, as. The weight coefficient for the wave field coherent with that calculated in the absence of reflection agrees with the coefficient for strong single pass damping of an earlier developed heuristic model, for which the weight coefficients were obtained empirically using a full wave code to calculate the wave field and power deposition. Antennas launching electromagnetic waves into bounded domains are often designed to produce localised wave fields and power depositions in the limit of strong single pass damping. The reflection of the waves changes the coupling that partly destroys the localisation of the wave field, which explains the apparent paradox arising from the earlier developed heuristic formula that only a fraction as2(2-as) and not as of the power is absorbed with a profile corresponding to the power deposition for the first pass of the rays. A method to account for the change in the coupling spectrum caused by reflection for modelling the wave field with ray tracing in bounded media is proposed, which should be applicable to wave propagation in non-uniform media in more general geometries.
Görgülü, S; Ayyıldız, S; Gökçe, S; Ozen, T
2014-01-01
Objectives: To evaluate the heating and magnetic field interactions of fixed orthodontic appliances with different wires and ligaments in a 3-T MRI environment and to estimate the safety of these orthodontic materials. Methods: 40 non-carious extracted human maxillary teeth were embedded in polyvinyl chloride boxes, and orthodontic brackets were bonded. Nickel–titanium and stainless steel arch wires, and elastic and stainless steel ligaments were used to obtain four experimental groups in total. Specimens were evaluated at 3 T for radiofrequency heating and magnetic field interactions. Radiofrequency heating was evaluated by placing specimens in a cylindrical plastic container filled with isotonic solution and measuring changes in temperature after T1 weighted axial sequencing and after completion of all sequences. Translational attraction and torque values of specimens were also evaluated. One-way ANOVA test was used to compare continuous variables of temperature change. Significance was set at p < 0.05. Results: None of the groups exhibited excessive heating (highest temperature change: <3.04 °C), with the maximum increase in temperature observed at the end of the T1 weighted axial sequence. Magnetic field interactions changed depending on the material used. Although the brackets presented minor interactions that would not cause movement in situ, nickel–titanium and stainless steel wires presented great interactions that may pose a risk for the patient. Conclusions: The temperature changes of the specimens were considered to be within acceptable ranges. With regard to magnetic field interactions, brackets can be considered “MR safe”; however, it would be safe to replace the wires before MRI. PMID:24257741
Bourke, Tara; Buch, Eric; Mathuria, Nilesh; Michowitz, Yoav; Yu, Ricky; Mandapati, Ravi; Shivkumar, Kalyanam; Tung, Roderick
2014-01-01
Background There is a paucity of data on biophysical parameters during radiofrequency ablation of scar-mediated ventricular tachycardia (VT). Methods and Results Data was collected from consecutive patients undergoing VT ablation with open-irrigation. Complete data was available for 372 lesions in 21 patients. The frequency of biophysical parameter changes were: >10Ω reduction (80%), bipolar EGM reduction (69%), while loss of capture was uncommon (32%). Unipolar injury current was seen in 72% of radiofrequency applications. Both EGM reduction and impedance drop were seen in 57% and a change in all 3 parameters was seen in only 20% of lesions. Late potentials were eliminated in 33%, reduced/modified in 56%, and remained after ablation in 11%. Epicardial lesions exhibited an impedance drop (90% vs 76%, p=0.002) and loss of capture (46% vs 27%, p<0.001) more frequently than endocardial lesions. Lesions delivered manually exhibited a >10Ω impedance drop (83% vs 71%, p=0.02) and an EGM reduction (71% vs 40%, p< 0.001) more frequently than lesions applied using magnetic navigation, although loss of capture, elimination of LPs, and a change in all 3 parameters were similarly observed. Conclusions VT ablation is inefficient as the majority of radiofrequency lesions do not achieve more than one targeted biophysical parameter. Only one-third of RF applications targeted at LPs result in complete elimination. Epicardial ablation within scar may be more effective than endocardial lesions and lesions applied manually may be more effective than lesions applied using magnetic navigation. New technologies directed at identifying and optimizing ablation effectiveness in scar are clinically warranted. PMID:24946895
Bourke, Tara; Buch, Eric; Mathuria, Nilesh; Michowitz, Yoav; Yu, Ricky; Mandapati, Ravi; Shivkumar, Kalyanam; Tung, Roderick
2014-11-01
There is a paucity of data on biophysical parameters during radiofrequency ablation of scar-mediated ventricular tachycardia (VT). Data were collected from consecutive patients undergoing VT ablation with open-irrigation. Complete data were available for 372 lesions in 21 patients. The frequency of biophysical parameter changes were: >10Ω reduction (80%), bipolar EGM reduction (69%), while loss of capture was uncommon (32%). Unipolar injury current was seen in 72% of radiofrequency applications. Both EGM reduction and impedance drop were seen in 57% and a change in all 3 parameters was seen in only 20% of lesions. Late potentials were eliminated in 33%, reduced/modified in 56%, and remained after ablation in 11%. Epicardial lesions exhibited an impedance drop (90% vs. 76%, P = 0.002) and loss of capture (46% vs. 27%, P < 0.001) more frequently than endocardial lesions. Lesions delivered manually exhibited a >10Ω impedance drop (83% vs. 71%, P = 0.02) and an EGM reduction (71% vs. 40%, P < 0.001) more frequently than lesions applied using magnetic navigation, although loss of capture, elimination of LPs, and a change in all 3 parameters were similarly observed. VT ablation is inefficient as the majority of radiofrequency lesions do not achieve more than one targeted biophysical parameter. Only one-third of RF applications targeted at LPs result in complete elimination. Epicardial ablation within scar may be more effective than endocardial lesions, and lesions applied manually may be more effective than lesions applied using magnetic navigation. New technologies directed at identifying and optimizing ablation effectiveness in scar are clinically warranted. © 2014 Wiley Periodicals, Inc.
Measuring and modeling of radiofrequency dielectric properties of chicken breast meat
USDA-ARS?s Scientific Manuscript database
Dielectric properties of chicken breast meat are important for both dielectric heating and quality sensing applications. In heating applications they allow optimization of energy transfer and uniformity of heating. In sensing applications, they can be used to predict quality attributes of the chicke...
Oulmane, F; Detti, V; Grenier, D; Perrin, E; Saint-Jalmes, H
2007-01-01
The presence of metallic conductors (implants, wires or catheters) is prohibited in MR imaging for safety purpose with respect to radiofrequency (RF) power deposition caused by RF excitation B1 field. This work describes the use of T1-weigthed MR imaging for estimating a thermal map around a metallic (copper) wire located in the center of a MR imaging unit during an imaging sequence. The experimental set up and the methodology used for capturing the elevation of temperature created by radiofrequency power deposition around the wire is presented. A proof of its efficiency to followup temperature elevation about 0,5 degrees C in a milimetric region of interest (pixel size: 1 x 1 mm2, slice thickness 5 mm) located around the wire is given, leading to further developments of MR imaging in presence of metallic implants, coils or catheters.
Large-Velocity Saturation in Thin-Film Black Phosphorus Transistors.
Chen, Xiaolong; Chen, Chen; Levi, Adi; Houben, Lothar; Deng, Bingchen; Yuan, Shaofan; Ma, Chao; Watanabe, Kenji; Taniguchi, Takashi; Naveh, Doron; Du, Xu; Xia, Fengnian
2018-05-22
A high saturation velocity semiconductor is appealing for applications in electronics and optoelectronics. Thin-film black phosphorus (BP), an emerging layered semiconductor, shows a high carrier mobility and strong mid-infrared photoresponse at room temperature. Here, we report the observation of high intrinsic saturation velocity in 7 to 11 nm thick BP for both electrons and holes as a function of charge-carrier density, temperature, and crystalline direction. We distinguish a drift velocity transition point due to the competition between the electron-impurity and electron-phonon scatterings. We further achieve a room-temperature saturation velocity of 1.2 (1.0) × 10 7 cm s -1 for hole (electron) carriers at a critical electric field of 14 (13) kV cm -1 , indicating an intrinsic current-gain cutoff frequency ∼20 GHz·μm for radio frequency applications. Moreover, the current density is as high as 580 μA μm -1 at a low electric field of 10 kV cm -1 . Our studies demonstrate that thin-film BP outperforms silicon in terms of saturation velocity and critical field, revealing its great potential in radio-frequency electronics, high-speed mid-infrared photodetectors, and optical modulators.
Carotid Angioplasty and Stenting
... and of the blood flow to the brain. Magnetic resonance angiography (MRA) or computerized tomography angiography (CTA). ... vessels by using either radiofrequency waves in a magnetic field or by using X-rays with contrast ...
Compact Superconducting Radio-frequency Accelerators and Innovative RF Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kephart, Robert; Chattopadhyay, Swaapan; Milton, Stephen
2015-04-10
We will present several new technical and design breakthroughs that enable the creation of a new class of compact linear electron accelerators for industrial purposes. Use of Superconducting Radio-Frequency (SRF) cavities allow accelerators less than 1.5 M in length to create electron beams beyond 10 MeV and with average beam powers measured in 10’s of KW. These machines can have the capability to vary the output energy dynamically to produce brehmstrahlung x-rays of varying spectral coverage for applications such as rapid scanning of moving cargo for security purposes. Such compact accelerators will also be cost effective for many existing andmore » new industrial applications. Examples include radiation crosslinking of plastics and rubbers, creation of pure materials with surface properties radically altered from the bulk, modification of bulk or surface optical properties of materials, sterilization of medical instruments animal solid or liquid waste, and destruction of organic compounds in industrial waste water effluents. Small enough to be located on a mobile platform, such accelerators will enable new remediation methods for chemical and biological spills and/or in-situ crosslinking of materials. We will describe one current design under development at Fermilab including plans for prototype and value-engineering to reduce costs. We will also describe development of new nano-structured field-emitter arrays as sources of electrons, new methods for fabricating and cooling superconducting RF cavities, and a new novel RF power source based on magnetrons with full phase and amplitude control.« less
Zhang, Kun; Li, Pei; Chen, Hangrong; Bo, Xiaowan; Li, Xiaolong; Xu, Huixiong
2016-02-23
Lowering power output and radiation time during radiofrequency (RF) ablation is still a challenge. Although it is documented that metal-based magnetothermal conversion and microbubbles-based inertial cavitation have been tried to overcome above issues, disputed toxicity and poor magnetothermal conversion efficiency for metal-based nanoparticles and violent but transient cavitation for microbubbles are inappropriate for enhancing RF ablation. In this report, a strategy, i.e., continuous cavitation, has been proposed, and solid menthol-encapsulated poly lactide-glycolide acid (PLGA) nanocapsules have been constructed, as a proof of concept, to validate the role of such a continuous cavitation principle in continuously enhancing RF ablation. The synthesized PLGA-based nanocapsules can respond to RF to generate menthol bubbles via distinctive radiofrequency solidoid vaporization (RSV) process, meanwhile significantly enhance ultrasound imaging for HeLa solid tumor, and further facilitate RF ablation via the continuous cavitation, as systematically demonstrated both in vitro and in vivo. Importantly, this RSV strategy can overcome drawbacks and limitations of acoustic droplet vaporization (ADV) and optical droplet vaporization (ODV), and will probably find broad applications in further cancer theranostics.
Miyazaki, Shinsuke; Ichihara, Noboru; Nakamura, Hiroaki; Taniguchi, Hiroshi; Hachiya, Hitoshi; Araki, Makoto; Takagi, Takamitsu; Iwasawa, Jin; Kuroi, Akio; Hirao, Kenzo; Iesaka, Yoshito
2016-04-01
Right phrenic nerve injury (PNI) is a major concern during superior vena cava (SVC) isolation due to the anatomical close proximity. The functional and histological severity of PNI parallels the degree of the reduction in the compound motor action potential (CMAP) amplitude. This study aimed to evaluate the feasibility of monitoring CMAPs during SVC isolation to anticipate PNI during atrial fibrillation (AF) ablation. Thirty-nine paroxysmal AF patients were prospectively enrolled. Radiofrequency energy was delivered point-by-point for 30 seconds with 20 W until eliminating all SVC potentials after the pulmonary vein isolation. Right diaphragmatic CMAPs were obtained from modified surface electrodes by pacing from the right subclavian vein. Radiofrequency applications were applied without fluoroscopy under CMAP monitoring at sites with phrenic nerve capture by high output pacing. Electrical SVC isolation was successfully achieved with a mean of 9.4 ± 3.3 applications in all patients. In 3 (7.5%) patients, the SVC was isolated without radiofrequency delivery at phrenic nerve capture sites. Among a total of 346 applications in the remaining 36 patients, 71 (20.5%) were delivered while monitoring CMAPs. In 1 (1.4%) application, the RF application was interrupted due to a decrease in the CMAP amplitude. However, no PNI was detected on fluoroscopy, and the decreased amplitude recovered spontaneously. The remaining 70 (98.6%) applications exhibited no significant changes in the CMAP amplitude throughout the applications (from 1.01 ± 0.47 to 0.98 ± 0.45 mV, P = 0.383). Stable right diaphragmatic CMAPs could be obtained, and monitoring CMAPs might be useful for anticipating right PNI during SVC isolation. © 2016 Wiley Periodicals, Inc.
Gryz, Krzysztof; Karpowicz, Jolanta
2014-01-01
Electromagnetic fields used in physiotherapeutic treatment affect not only patients, but also physiotherapists, patients not undergoing treatment and electronic medical equipment. The aim of the work was to study the parameters of the electromagnetic fields of physiotherapeutic devices with respect to requirements regarding the protection of electronic devices, including medical implants, against electromagnetic intererence, and the protection of the general public (patients not undergoing treatment and bystanders), as well as medical personnel, against the health hazards caused by electromagnetic exposure. The spatial distribution of electric and magnetic field strength was investigated near 3 capacitive short-wave and 3 long-wave diathermies and 3 ultrasound therapy units, as along with the capacitive electric currents caused by electromagnetic field interaction in the upper limbs of the physiotherapists operating these devices. The physiotherapists' exposure to electromagnetic fields depends on the spatial organisation of the workspace and their location during treatment. Electric fields able to interfere with the function of electronic medical implants and in whic anyone not undergoing treatment should not be present were measured up to 150-200 cm away from active applicators of short-wave diathermy, and up to 40-45 cm away from long-wave diathermy ones. Electric fields in which workers should not be present were measured up to 30-40 cm away from the applicators and cables of active short-wave diathermy devices. A capacitive electric current with a strength exceeding many times the international recommendations regarding workers protection was measured in the wrist while touching applicators and cables of active short-wave diathermy devices. The strongest environmental electromagnetic hazards occur near short-wave diathermy devices, and to a lesser degree near long-wave diathermy devices, but were not found near ultrasound therapy units.
Vaidya, Manushka V; Collins, Christopher M; Sodickson, Daniel K; Brown, Ryan; Wiggins, Graham C; Lattanzi, Riccardo
2016-02-01
In high field MRI, the spatial distribution of the radiofrequency magnetic ( B 1 ) field is usually affected by the presence of the sample. For hardware design and to aid interpretation of experimental results, it is important both to anticipate and to accurately simulate the behavior of these fields. Fields generated by a radiofrequency surface coil were simulated using dyadic Green's functions, or experimentally measured over a range of frequencies inside an object whose electrical properties were varied to illustrate a variety of transmit [Formula: see text] and receive [Formula: see text] field patterns. In this work, we examine how changes in polarization of the field and interference of propagating waves in an object can affect the B 1 spatial distribution. Results are explained conceptually using Maxwell's equations and intuitive illustrations. We demonstrate that the electrical conductivity alters the spatial distribution of distinct polarized components of the field, causing "twisted" transmit and receive field patterns, and asymmetries between [Formula: see text] and [Formula: see text]. Additionally, interference patterns due to wavelength effects are observed at high field in samples with high relative permittivity and near-zero conductivity, but are not present in lossy samples due to the attenuation of propagating EM fields. This work provides a conceptual framework for understanding B 1 spatial distributions for surface coils and can provide guidance for RF engineers.
Marking multi-channel silicon-substrate electrode recording sites using radiofrequency lesions.
Brozoski, Thomas J; Caspary, Donald M; Bauer, Carol A
2006-01-30
Silicon-substrate multi-channel electrodes (multiprobes) have proven useful in a variety of electrophysiological tasks. When using multiprobes it is often useful to identify the site of each channel, e.g., when recording single-unit activity from a heterogeneous structure. Lesion marking of electrode sites has been used for many years. Electrolytic, or direct current (DC) lesions, have been used successfully to mark multiprobe sites in rat hippocampus [Townsend G, Peloquin P, Kloosterman F, Hetke JF, Leung LS. Recording and marking with silicon multichannel electrodes. Brain Res Brain Res Protoc 2002;9:122-9]. The present method used radio-frequency (rf) lesions to distinctly mark each of the 16 recording sites of 16-channel linear array multiprobes, in chinchilla inferior colliculus. A commercial radio-frequency lesioner was used as the current source, in conjunction with custom connectors adapted to the multiprobe configuration. In vitro bench testing was used to establish current-voltage-time parameters, as well as to check multiprobe integrity and radio-frequency performance. In in vivo application, visualization of individual-channel multiprobe recording sites was clear in 21 out of 33 sets of collicular serial-sections (i.e., probe tracks) obtained from acute experimental subjects, i.e., maximum post-lesion survival time of 2h. Advantages of the rf method include well-documented methods of in vitro calibration as well as low impact on probe integrity. The rf method of marking individual-channel sites should be useful in a variety of applications.
Roozbeh, Nasibeh; Abdi, Fatemeh; Amraee, Azadeh; Atarodi Kashani, Zahra; Darvish, Leili
2018-02-08
Due to the increased number of users of mobile phones, tablets, and other devices over the past few years, concerns about the potential impact of mobile phones on health are growing. The influence of mobile phone exposure on male fertility has been studied in recent years. Other research has shown that electromagnetic fields (EMFs) increase macrophages in the corpus luteum and growing follicles. Due to conflicting results among studies and since no systematic review has been performed to analyze the effects of radiofrequency EMF exposure from electronic devices on the fertility system in recent years, this evidence-based study is necessary. The main objectives of this study are to determine the best evidence associated with the influence of radiofrequency EMFs on the fertility system and to provide insight into a potential mechanism using our observations. In this systematic review, the databases and gray literature will be searched with no language and date limitation. The following databases will be searched: Cochrane Library, MEDLINE, PubMed, EMBASE, CINAHL, ProQuest, Scopus, Science Direct, Google Scholar, and other Persian databases. The combination of the Medical Subject Heading terms "radiofrequency electromagnetic" and "male reproductive system" or "female reproductive system" will be searched. Observational study designs will be included but case reports, case series, reviews, and letters to the editor will be excluded. Papers selected for retrieval will be evaluated by two independent referees for methodological validation before entering a review using the Newcastle-Ottawa Scale for nonrandomized studies and cohort studies. The results of this study will be submitted to a peer-reviewed journal for publication and also presented at PROSPERO. This systematic review will provide evidence-based data on the effect of radiofrequency EMFs on the fertility system. This article will also classify the harmful effect of radiofrequency waves on primary and secondary infertility. This study could be useful for decreasing infertility. This is important because the rate of infertility is growing, leading to negative outcomes for couples and the health care system. PROSPERO CRD42017072462; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=72462 (Archived by WebCite at http://www.webcitation.org/6wjiE9R2q). ©Nasibeh Roozbeh, Fatemeh Abdi, Azadeh Amraee, Zahra Atarodi Kashani, Leili Darvish. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 08.02.2018.
Dielectric properties of agricultural materials and their application
USDA-ARS?s Scientific Manuscript database
This book is prepared as a comprehensive source of information on dielectric properties of agricultural materials for scientific researchers and engineers involved in practical application of radio-frequency and microwave energy for potential problem solutions. Dielectric properties of materials det...
Use of a new high-speed digital data acquisition system in airborne ice-sounding
Wright, David L.; Bradley, Jerry A.; Hodge, Steven M.
1989-01-01
A high-speed digital data acquisition and signal averaging system for borehole, surface, and airborne radio-frequency geophysical measurements was designed and built by the US Geological Survey. The system permits signal averaging at rates high enough to achieve significant signal-to-noise enhancement in profiling, even in airborne applications. The first field use of the system took place in Greenland in 1987 for recording data on a 150 by 150-km grid centered on the summit of the Greenland ice sheet. About 6000-line km were flown and recorded using the new system. The data can be used to aid in siting a proposed scientific corehole through the ice sheet.
S-band 1.4 cell photoinjector design for high brightness beam generation
NASA Astrophysics Data System (ADS)
Pirez, E.; Musumeci, P.; Maxson, J.; Alesini, D.
2017-09-01
In this paper we study in detail the design of a novel S-band radiofrequency photogun structure to maximize the accelerating field experienced by the particles at injection. This is a critical quantity for electron sources as it has a direct impact on the maximum brightness achievable. The proposed design is based on a modification of the latest generation of S-band RF photoinjectors to include novel fabrication approaches. The gun is designed to operate at a 120 MV/m gradient and at an optimal injection phase of 70° providing the beam quality required to enable novel electron beam applications such as single shot time-resolved transmission electron microscopy and ultrafast electron nanodiffraction.
NASA Astrophysics Data System (ADS)
Cesar, D.; Maxson, J.; Musumeci, P.; Sun, Y.; Harrison, J.; Frigola, P.; O'Shea, F. H.; To, H.; Alesini, D.; Li, R. K.
2016-07-01
We present the results of an experiment where a short focal length (˜1.3 cm ), permanent magnet electron lens is used to image micron-size features (of a metal sample) with a single shot from an ultrahigh brightness picosecond-long 4 MeV electron beam emitted by a radio-frequency photoinjector. Magnification ratios in excess of 30 × were obtained using a triplet of compact, small gap (3.5 mm), Halbach-style permanent magnet quadrupoles with nearly 600 T /m field gradients. These results pave the way towards single-shot time-resolved electron microscopy and open new opportunities in the applications of high brightness electron beams.
Risk assessment and management of radiofrequency radiation exposure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dabala, Dana; Surducan, Emanoil; Surducan, Vasile
2013-11-13
Radiofrequency radiation (RFR) industry managers, occupational physicians, security department, and other practitioners must be advised on the basic of biophysics and the health effects of RF electromagnetic fields so as to guide the management of exposure. Information on biophysics of RFR and biological/heath effects is derived from standard texts, literature and clinical experiences. Emergency treatment and ongoing care is outlined, with clinical approach integrating the circumstances of exposure and the patient's symptoms. Experimental risk assessment model in RFR chronic exposure is proposed. Planning for assessment and monitoring exposure, ongoing care, safety measures and work protection are outlining the proper management.
Characterization of superconducting radiofrequency breakdown by two-mode excitation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eremeev, Grigory V.; Palczewski, Ari D.
2014-01-14
We show that thermal and magnetic contributions to the breakdown of superconductivity in radiofrequency (RF) fields can be separated by applying two RF modes simultaneously to a superconducting surface. We develop a simple model that illustrates how mode-mixing RF data can be related to properties of the superconductor. Within our model the data can be described by a single parameter, which can be derived either from RF or thermometry data. Our RF and thermometry data are in good agreement with the model. We propose to use mode-mixing technique to decouple thermal and magnetic effects on RF breakdown of superconductors.
Internal zone growth method for producing metal oxide metal eutectic composites
Clark, Grady W.; Holder, John D.; Pasto, Arvid E.
1980-01-01
An improved method for preparing a cermet comprises preparing a compact having about 85 to 95 percent theoretical density from a mixture of metal and metal oxide powders from a system containing a eutectic composition, and inductively heating the compact in a radiofrequency field to cause the formation of an internal molten zone. The metal oxide particles in the powder mixture are effectively sized relative to the metal particles to permit direct inductive heating of the compact by radiofrequency from room temperature. Surface melting is prevented by external cooling or by effectively sizing the particles in the powder mixture.
Generation of constant-amplitude radio-frequency sweeps at a tunnel junction for spin resonance STM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paul, William; Lutz, Christopher P.; Heinrich, Andreas J.
2016-07-15
We describe the measurement and successful compensation of the radio-frequency transfer function of a scanning tunneling microscope over a wide frequency range (15.5–35.5 GHz) and with high dynamic range (>50 dB). The precise compensation of cabling resonances and attenuations is critical for the production of constant-voltage frequency sweeps for electric-field driven electron spin resonance (ESR) experiments. We also demonstrate that a well-calibrated tunnel junction voltage is necessary to avoid spurious ESR peaks that can arise due to a non-flat transfer function.
Wireless monitoring of the biological object state at microwave frequencies: A review
NASA Astrophysics Data System (ADS)
Vendik, I. B.; Vendik, O. G.; Kozlov, D. S.; Munina, I. V.; Pleskachev, V. V.; Rusakov, A. S.; Tural'chuk, P. A.
2016-01-01
Radio-frequency identification systems used for the remote diagnostics of diseases and contactless monitoring and assessment of human health are reviewed. The propagation of electromagnetic waves inside a biological medium and along interfaces between different media, as well as the problem of telemetry data acquisition from implanted systems or system on the human body surface using wireless sensors, is considered. Emphasis is on radio-frequency identification systems that use far-field electromagnetic radiation, since they are necessary in emergency situations to find injured people in hard-to-reach places and assess the state of emergency response workers.
Risk assessment and management of radiofrequency radiation exposure
NASA Astrophysics Data System (ADS)
Dabala, Dana; Surducan, Emanoil; Surducan, Vasile; Neamtu, Camelia
2013-11-01
Radiofrequency radiation (RFR) industry managers, occupational physicians, security department, and other practitioners must be advised on the basic of biophysics and the health effects of RF electromagnetic fields so as to guide the management of exposure. Information on biophysics of RFR and biological/heath effects is derived from standard texts, literature and clinical experiences. Emergency treatment and ongoing care is outlined, with clinical approach integrating the circumstances of exposure and the patient's symptoms. Experimental risk assessment model in RFR chronic exposure is proposed. Planning for assessment and monitoring exposure, ongoing care, safety measures and work protection are outlining the proper management.
Optimization of the generator settings for endobiliary radiofrequency ablation.
Barret, Maximilien; Leblanc, Sarah; Vienne, Ariane; Rouquette, Alexandre; Beuvon, Frederic; Chaussade, Stanislas; Prat, Frederic
2015-11-10
To determine the optimal generator settings for endobiliary radiofrequency ablation. Endobiliary radiofrequency ablation was performed in live swine on the ampulla of Vater, the common bile duct and in the hepatic parenchyma. Radiofrequency ablation time, "effect", and power were allowed to vary. The animals were sacrificed two hours after the procedure. Histopathological assessment of the depth of the thermal lesions was performed. Twenty-five radiofrequency bursts were applied in three swine. In the ampulla of Vater (n = 3), necrosis of the duodenal wall was observed starting with an effect set at 8, power output set at 10 W, and a 30 s shot duration, whereas superficial mucosal damage of up to 350 μm in depth was recorded for an effect set at 8, power output set at 6 W and a 30 s shot duration. In the common bile duct (n = 4), a 1070 μm, safe and efficient ablation was obtained for an effect set at 8, a power output of 8 W, and an ablation time of 30 s. Within the hepatic parenchyma (n = 18), the depth of tissue damage varied from 1620 μm (effect = 8, power = 10 W, ablation time = 15 s) to 4480 μm (effect = 8, power = 8 W, ablation time = 90 s). The duration of the catheter application appeared to be the most important parameter influencing the depth of the thermal injury during endobiliary radiofrequency ablation. In healthy swine, the currently recommended settings of the generator may induce severe, supratherapeutic tissue damage in the biliary tree, especially in the high-risk area of the ampulla of Vater.
To explain a carrier frequency dependence reported for radiofrequency (RF)-induced calcium-ion efflux from brain tissue, a chick-brain hemisphere bathed in buffer solution is modeled as a sphere within the uniform field of the incident electromagnetic wave. Calculations on a sphe...
Sage, Cindy; Burgio, Ernesto
2018-01-01
Mobile phones and other wireless devices that produce electromagnetic fields (EMF) and pulsed radiofrequency radiation (RFR) are widely documented to cause potentially harmful health impacts that can be detrimental to young people. New epigenetic studies are profiled in this review to account for some neurodevelopmental and neurobehavioral changes due to exposure to wireless technologies. Symptoms of retarded memory, learning, cognition, attention, and behavioral problems have been reported in numerous studies and are similarly manifested in autism and attention deficit hyperactivity disorders, as a result of EMF and RFR exposures where both epigenetic drivers and genetic (DNA) damage are likely contributors. Technology benefits can be realized by adopting wired devices for education to avoid health risk and promote academic achievement. © 2017 The Authors. Child Development © 2017 Society for Research in Child Development, Inc.
Sannino, Anna; Zeni, Olga; Romeo, Stefania; Massa, Rita; Gialanella, Giancarlo; Grossi, Gianfranco; Manti, Lorenzo; Vijayalaxmi; Scarfì, Maria Rosaria
2014-03-01
The aim of this preliminary investigation was to assess whether human peripheral blood lymphocytes which have been pre-exposed to non-ionizing radiofrequency fields exhibit an adaptive response (AR) by resisting the induction of genetic damage from subsequent exposure to ionizing radiation. Peripheral blood lymphocytes from four healthy donors were stimulated with phytohemagglutinin for 24 h and then exposed for 20 h to 1950 MHz radiofrequency fields (RF, adaptive dose, AD) at an average specific absorption rate of 0.3 W/kg. At 48 h, the cells were subjected to a challenge dose (CD) of 1.0 or 1.5 Gy X-irradiation (XR, challenge dose, CD). After a 72 h total culture period, cells were collected to examine the incidence of micronuclei (MN). There was a significant decrease in the number of MN in lymphocytes exposed to RF + XR (AD + CD) as compared with those subjected to XR alone (CD). These observations thus suggested a RF-induced AR and induction of resistance to subsequent damage from XR. There was variability between the donors in RF-induced AR. The data reported in our earlier investigations also indicated a similar induction of AR in human blood lymphocytes that had been pre-exposed to RF (AD) and subsequently treated with a chemical mutagen, mitomycin C (CD). Since XR and mitomycin-C induce different kinds of lesions in cellular DNA, further studies are required to understand the mechanism(s) involved in the RF-induced adaptive response.
Sannino, Anna; Zeni, Olga; Romeo, Stefania; Massa, Rita; Gialanella, Giancarlo; Grossi, Gianfranco; Manti, Lorenzo; Vijayalaxmi; Scarfì, Maria Rosaria
2014-01-01
The aim of this preliminary investigation was to assess whether human peripheral blood lymphocytes which have been pre-exposed to non-ionizing radiofrequency fields exhibit an adaptive response (AR) by resisting the induction of genetic damage from subsequent exposure to ionizing radiation. Peripheral blood lymphocytes from four healthy donors were stimulated with phytohemagglutinin for 24 h and then exposed for 20 h to 1950 MHz radiofrequency fields (RF, adaptive dose, AD) at an average specific absorption rate of 0.3 W/kg. At 48 h, the cells were subjected to a challenge dose (CD) of 1.0 or 1.5 Gy X-irradiation (XR, challenge dose, CD). After a 72 h total culture period, cells were collected to examine the incidence of micronuclei (MN). There was a significant decrease in the number of MN in lymphocytes exposed to RF + XR (AD + CD) as compared with those subjected to XR alone (CD). These observations thus suggested a RF-induced AR and induction of resistance to subsequent damage from XR. There was variability between the donors in RF-induced AR. The data reported in our earlier investigations also indicated a similar induction of AR in human blood lymphocytes that had been pre-exposed to RF (AD) and subsequently treated with a chemical mutagen, mitomycin C (CD). Since XR and mitomycin-C induce different kinds of lesions in cellular DNA, further studies are required to understand the mechanism(s) involved in the RF-induced adaptive response. PMID:23979077
Landmarks in the historical development of twenty first century food processing technologies.
Misra, N N; Koubaa, Mohamed; Roohinejad, Shahin; Juliano, Pablo; Alpas, Hami; Inácio, Rita S; Saraiva, Jorge A; Barba, Francisco J
2017-07-01
Over a course of centuries, various food processing technologies have been explored and implemented to provide safe, fresher-tasting and nutritive food products. Among these technologies, application of emerging food processes (e.g., cold plasma, pressurized fluids, pulsed electric fields, ohmic heating, radiofrequency electric fields, ultrasonics and megasonics, high hydrostatic pressure, high pressure homogenization, hyperbaric storage, and negative pressure cavitation extraction) have attracted much attention in the past decades. This is because, compared to their conventional counterparts, novel food processes allow a significant reduction in the overall processing times with savings in energy consumption, while ensuring food safety, and ample benefits for the industry. Noteworthily, industry and university teams have made extensive efforts for the development of novel technologies, with sound scientific knowledge of their effects on different food materials. The main objective of this review is to provide a historical account of the extensive efforts and inventions in the field of emerging food processing technologies since their inception to present day. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nusinovich, Gregory S.; Chainani, Samir; Granatstein, Victor L.
The theory is developed for analyzing the effect of transverse nonuniformity of the radiofrequency (rf) field on the starting conditions and efficiency of such gyrotron oscillators as gyromonotrons and gyro-backward-wave oscillators (gyro-BWO). The formalism allows one to study this effect in oscillators operating in the regimes of soft and hard self-excitation. Results obtained for a device with a confocal waveguide (or resonator) are compared with the results for conventional gyrodevices where the rf field acting on electrons with different guiding centers is the same. It is shown how to use results of the classical small-signal theory of backward-wave oscillators drivenmore » by linear electron beams for calculating the start currents in gyro-BWOs. The effect of the wave attenuation in waveguide walls on the start current is analyzed, which is important for the design of frequency-tunable gyro-backward-wave oscillators in the THz (and sub THz) frequency range.« less
Occupational exposure of personnel operating military radio equipment: measurements and simulation.
Paljanos, Annamaria; Miclaus, Simona; Munteanu, Calin
2015-09-01
Technical literature provides numerous studies concerning radiofrequency exposure measurements for various radio communication devices, but there are few studies related to exposure of personnel operating military radio equipment. In order to evaluate exposure and identify cases when safety requirements are not entirely met, both measurements and simulations are needed for accurate results. Moreover, given the technical characteristics of the radio devices used in the military, personnel mainly operate in the near-field region so both measurements and simulation becomes more complex. Measurements were made in situ using a broadband personal exposimeter equipped with two isotropic probes for both electric and magnetic components of the field. The experiment was designed for three different operating frequencies of the same radio equipment, while simulations were made in FEKO software using hybrid numerical methods to solve complex electromagnetic field problems. The paper aims to discuss the comparative results of the measurements and simulation, as well as comparing them to reference levels specified in military or civilian radiofrequency exposure standards.
Baste, Valborg; Mild, Kjell Hansson; Moen, Bente E
2010-07-01
Epidemiological studies related to radiofrequency (RF) electromagnetic fields (EMF) have mainly used crude proxies for exposure, such as job titles, distance to, or use of different equipment emitting RF EMF. The Royal Norwegian Navy (RNoN) has measured RF field emitted from high-frequency antennas and radars on several spots where the crew would most likely be located aboard fast patrol boats (FPB). These boats are small, with short distance between the crew and the equipment emitting RF field. We have described the measured RF exposure aboard FPB and suggested different methods for calculations of total exposure and annual dose. Linear and spatial average in addition to percentage of ICNIRP and squared deviation of ICNIRP has been used. The methods will form the basis of a job exposure matrix where relative differences in exposure between groups of crew members can be used in further epidemiological studies of reproductive health. 2010 Wiley-Liss, Inc.
National surveys of radiofrequency field strengths from radio base stations in Africa
Joyner, Ken H.; Van Wyk, Marthinus J.; Rowley, Jack T.
2014-01-01
The authors analysed almost 260 000 measurement points from surveys of radiofrequency (RF) field strengths near radio base stations in seven African countries over two time frames from 2001 to 2003 and 2006 to 2012. The results of the national surveys were compared, chronological trends investigated and potential exposures compared by technology and with frequency modulation (FM) radio. The key findings from thes data are that irrespective of country, the year and mobile technology, RF fields at a ground level were only a small fraction of the international human RF exposure recommendations. Importantly, there has been no significant increase in typical measured levels since the introduction of 3G services. The mean levels in these African countries are similar to the reported levels for countries of Asia, Europe and North America using similar mobile technologies. The median level for the FM services in South Africa was comparable to the individual but generally lower than the combined mobile services. PMID:24044904
NASA Astrophysics Data System (ADS)
Schneider, Jens; Holzer, Frank; Rabe, Carsten; Häupl, Tilmann; Kopinke, Frank-Dieter; Roland, Ulf
2013-04-01
Applying a new experimental design with a capillary glass reactor and plate electrodes outside of the reactor allowed the initiation of discharges in aqueous electrolytes under the influence of a radio-frequency (RF) electromagnetic field. This study focused on the mechanism leading to the initiation of such discharges in the restriction of a glass tube. The light emission correlated with discharges was analysed with optical emission spectroscopy. Electrons with energies between 20 and 45 eV were responsible for the dissociation of water molecules into (excited) OH, H and O radicals. Current-voltage characteristics were measured before and under discharge conditions. Modelling of the experimental setup and simulation of electrical field strength distribution support the hypothesis of the origin of discharges in general and experimental findings such as ring-shaped discharges and a minimum solution conductivity of about 1 S m-1 required for discharge initiation with RF voltages of 2 kV.
Vitale, W. A.; Tamagnone, M.; Émond, N.; Le Drogoff, B.; Capdevila, S.; Skrivervik, A.; Chaker, M.; Mosig, J. R.; Ionescu, A. M.
2017-01-01
The modulated scattering technique is based on the use of reconfigurable electromagnetic scatterers, structures able to scatter and modulate an impinging electromagnetic field in function of a control signal. The modulated scattering technique is used in a wide range of frequencies up to millimeter waves for various applications, such as field mapping of circuits or antennas, radio-frequency identification devices and imaging applications. However, its implementation in the terahertz domain remains challenging. Here, we describe the design and experimental demonstration of the modulated scattering technique at terahertz frequencies. We characterize a modulated scatterer consisting in a bowtie antenna loaded with a vanadium dioxide switch, actuated using a continuous current. The modulated scatterer behavior is demonstrated using a time domain terahertz spectroscopy setup and shows significant signal strength well above 0.5 THz, which makes this device a promising candidate for the development of fast and energy-efficient THz communication devices and imaging systems. Moreover, our experiments allowed us to verify the operation of a single micro-meter sized VO2 switch at terahertz frequencies, thanks to the coupling provided by the antenna. PMID:28145523
Ritz, Joerg-Peter; Lehmann, Kai S; Reissfelder, Christoph; Albrecht, Thomas; Frericks, Bernd; Zurbuchen, Urte; Buhr, Heinz J
2006-01-01
Radiofrequency ablation (RFA) is a promising method for local treatment of liver malignancies. Currently available systems for radiofrequency ablation use monopolar current, which carries the risk of uncontrolled electrical current paths, collateral damages and limited effectiveness. To overcome this problem, we used a newly developed internally cooled bipolar application system in patients with irresectable liver metastases undergoing laparotomy. The aim of this study was to clinically evaluate the safety, feasibility and effectiveness of this new system with a novel multipolar application concept. Patients with a maximum of five liver metastases having a maximum diameter of 5 cm underwent laparotomy and abdominal exploration to control resectability. In cases of irresectability, RFA with the newly developed bipolar application system was performed. Treatment was carried out under ultrasound guidance. Depending on tumour size, shape and location, up to three applicators were simultaneously inserted in or closely around the tumour, never exceeding a maximum probe distance of 3 cm. In the multipolar ablation concept, the current runs alternating between all possible pairs of consecutively activated electrodes with up to 15 possible electrode combinations. Post-operative follow-up was evaluated by CT or MRI controls 24-48 h after RFA and every 3 months. In a total of six patients (four male, two female; 61-68 years), ten metastases (1.0-5.5 cm) were treated with a total of 14 RF applications. In four metastases three probes were used, and in another four and two metastases, two and one probes were used, respectively. During a mean ablation time of 18.8 min (10-31), a mean energy of 48.8 kJ (12-116) for each metastases was applied. No procedure-related complications occurred. The patients were released from the hospital between 7 and 12 days post-intervention (median 9 days). The post-interventional control showed complete tumour ablation in all cases. Bipolar radiofrequency using the novel multipolar ablation concept permits a safe and effective therapy for the induction of large volumes of coagulation in the local treatment of liver metastases.
Searching for the Perfect Wave: The Effect of Radiofrequency Electromagnetic Fields on Cells
Gherardini, Lisa; Ciuti, Gastone; Tognarelli, Selene; Cinti, Caterina
2014-01-01
There is a growing concern in the population about the effects that environmental exposure to any source of “uncontrolled” radiation may have on public health. Anxiety arises from the controversial knowledge about the effect of electromagnetic field (EMF) exposure to cells and organisms but most of all concerning the possible causal relation to human diseases. Here we reviewed those in vitro and in vivo and epidemiological works that gave a new insight about the effect of radio frequency (RF) exposure, relating to intracellular molecular pathways that lead to biological and functional outcomes. It appears that a thorough application of standardized protocols is the key to reliable data acquisition and interpretation that could contribute a clearer picture for scientists and lay public. Moreover, specific tuning of experimental and clinical RF exposure might lead to beneficial health effects. PMID:24681584
Junginger, Tobias; Abidi, S. H.; Maffett, R. D.; ...
2018-03-16
Here, the performance of superconducting radiofrequency (SRF) cavities used for particle accelerators depends on two characteristic material parameters: field of first flux entry H entry and pinning strength. The former sets the limit for the maximum achievable accelerating gradient, while the latter determines how efficiently flux can be expelled related to the maximum achievable quality factor. In this paper, a method based on muon spin rotation (μSR) is developed to probe these parameters on samples. It combines measurements from two different spectrometers, one being specifically built for these studies and samples of different geometries. It is found that annealing atmore » 1400°C virtually eliminates all pinning. Such an annealed substrate is ideally suited to measure H entry of layered superconductors, which might enable accelerating gradients beyond bulk niobium technology.« less
Optimizing MRI for imaging peripheral arthritis.
Hodgson, Richard J; O'Connor, Philip J; Ridgway, John P
2012-11-01
MRI is increasingly used for the assessment of both inflammatory arthritis and osteoarthritis. The wide variety of MRI systems in use ranges from low-field, low-cost extremity units to whole-body high-field 7-T systems, each with different strengths for specific applications. The availability of dedicated radiofrequency phased-array coils allows the rapid acquisition of high-resolution images of one or more peripheral joints. MRI is uniquely flexible in its ability to manipulate image contrast, and individual MR sequences may be combined into protocols to sensitively visualize multiple features of arthritis including synovitis, bone marrow lesions, erosions, cartilage changes, and tendinopathy. Careful choice of the imaging parameters allows images to be generated with optimal quality while minimizing unwanted artifacts. Finally, there are many novel MRI techniques that can quantify disease levels in arthritis in tissues including synovitis and cartilage. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinello, M.; Aderhold, S.; Chandrasekaran, S. K.
The radio-frequency surface resistance of niobium resonators is incredibly reduced when nitrogen impurities are dissolved as interstitial in the material, conferring ultra-high Q-factors at medium values of accelerating field. This effect has been observed in both high and low temperature nitrogen treatments. As a matter of fact, the peculiar anti Q-slope observed in nitrogen doped cavities, i.e. the decreasing of the Q-factor with the increasing of the radio-frequency field, come from the decreasing of the BCS surface resistance component as a function of the field. Such peculiar behavior has been considered consequence of the interstitial nitrogen present in the niobiummore » lattice after the doping treatment. The study here presented show the field dependence of the BCS surface resistance of cavities with different resonant frequencies, such as: 650 MHz, 1.3 GHz, 2.6 GHz and 3.9 GHz, and processed with different state-of-the-art surface treatments. These findings show for the first time that the anti Q-slope might be seen at high frequency even for clean Niobium cavities, revealing useful suggestion on the physics underneath the anti Q-slope effect.« less
Pérez, Juan J; Pérez-Cajaraville, Juan J; Muñoz, Víctor; Berjano, Enrique
2014-07-01
Pulsed RF (PRF) is a nonablative technique for treating neuropathic pain. Bipolar PRF application is currently aimed at creating a "strip lesion" to connect the electrode tips; however, the electrical and thermal performance during bipolar PRF is currently unknown. The objective of this paper was to study the temperature and electric field distributions during bipolar PRF. The authors developed computer models to study temperature and electric field distributions during bipolar PRF and to assess the possible ablative thermal effect caused by the accumulated temperature spikes, along with any possible electroporation effects caused by the electrical field. The authors also modeled the bipolar ablative mode, known as bipolar Continuous Radiofrequency (CRF), in order to compare both techniques. There were important differences between CRF and PRF in terms of electrical and thermal performance. In bipolar CRF: (1) the initial temperature of the tissue impacts on temperature progress and hence on the thermal lesion dimension; and (2) at 37 °C, 6-min of bipolar CRF creates a strip thermal lesion between the electrodes when these are separated by a distance of up to 20 mm. In bipolar PRF: (1) an interelectrode distance shorter than 5 mm produces thermal damage (i.e., ablative effect) in the intervening tissue after 6 min of bipolar RF; and (2) the possible electroporation effect (electric fields higher than 150 kV m(-1)) would be exclusively circumscribed to a very small zone of tissue around the electrode tip. The results suggest that (1) the clinical parameters considered to be suitable for bipolar CRF should not necessarily be considered valid for bipolar PRF, and vice versa; and (2) the ablative effect of the CRF mode is mainly due to its much greater level of delivered energy than is the case in PRF, and therefore at same applied energy levels, CRF, and PRF are expected to result in same outcomes in terms of thermal damage zone dimension.
Active stabilization of ion trap radiofrequency potentials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, K. G.; Wong-Campos, J. D.; Restelli, A.
2016-05-15
We actively stabilize the harmonic oscillation frequency of a laser-cooled atomic ion confined in a radiofrequency (rf) Paul trap by sampling and rectifying the high voltage rf applied to the trap electrodes. We are able to stabilize the 1 MHz atomic oscillation frequency to be better than 10 Hz or 10 ppm. This represents a suppression of ambient noise on the rf circuit by 34 dB. This technique could impact the sensitivity of ion trap mass spectrometry and the fidelity of quantum operations in ion trap quantum information applications.
de Paola, A A; Mendonça, A; Balbão, C E; Tavora, M Z; da Silva, R M; Hara, V M; Guiguer Júnior, N; Vattimo, A C; Souza, I A; Portugal, O P
1993-10-01
A 8-year-old female patient with refractory incessant atrial tachycardia, very symptomatic and with left ventricular ejection fraction of 0.25. Electrophysiological study and endocardial mapping localized the site of the origin of atrial tachycardia in the superior right atrium. In this site 2 applications of radiofrequency current (25V, 20 and 50 seconds) resulted in termination of the atrial tachycardia. She was discharged off antiarrhythmic drugs and after 2 months ejection fraction was 0.52. She was completely asymptomatic 6 months after ablation procedure.
Anti-collision radio-frequency identification system using passive SAW tags
NASA Astrophysics Data System (ADS)
Sorokin, A. V.; Shepeta, A. P.
2017-06-01
Modern multi sensor systems should have high operating speed and resistance to climate impacts. Radiofrequency systems use passive SAW tags for identification items and vehicles. These tags find application in industry, traffic remote control systems, and railway remote traffic control systems for identification and speed measuring. However, collision of the passive SAW RFID tags hinders development passive RFID SAW technology in Industry. The collision problem for passive SAW tags leads for incorrect identification and encoding each tag. In our researching, we suggest approach for identification of several passive SAW tags in collision case.
Alternative food safety intervention technologies
USDA-ARS?s Scientific Manuscript database
Alternative nonthermal and thermal food safety interventions are gaining acceptance by the food processing industry and consumers. These technologies include high pressure processing, ultraviolet and pulsed light, ionizing radiation, pulsed and radiofrequency electric fields, cold atmospheric plasm...
Sucrose modulation of radiofrequency-induced heating rates and cell death.
Pulikkathara, Merlyn; Mark, Colette; Kumar, Natasha; Zaske, Ana Maria; Serda, Rita E
2017-09-01
Applied radiofrequency (RF) energy induces hyperthermia in tissues, facilitating vascular perfusion This study explores the impact of RF radiation on the integrity of the luminal endothelium, and then predominately explores the impact of altering the conductivity of biologically-relevant solutions on RF-induced heating rates and cell death. The ability of cells to survive high sucrose (i.e. hyperosmotic conditions) to achieve lower conductivity as a mechanism for directing hyperthermia is evaluated. RF radiation was generated using a capacitively-coupled radiofrequency system operating at 13.56 MHz. Temperatures were recorded using a FLIR SC 6000 infrared camera. RF radiation reduced cell-to-cell connections among endothelial cells and altered cell morphology towards a more rounded appearance at temperatures reported to cause in vivo vessel deformation. Isotonic solutions containing high sucrose and low levels of NaCl displayed low conductivity and faster heating rates compared to high salt solutions. Heating rates were positively correlated with cell death. Addition of sucrose to serum similarly reduced conductivity and increased heating rates in a dose-dependent manner. Cellular proliferation was normal for cells grown in media supplemented with 125 mM sucrose for 24 hours or for cells grown in 750 mM sucrose for 10 minutes followed by a 24 h recovery period. Sucrose is known to form weak hydrogen bonds in fluids as opposed to ions, freeing water molecules to rotate in an oscillating field of electromagnetic radiation and contributing to heat induction. The ability of cells to survive temporal exposures to hyperosmotic (i.e. elevated sucrose) conditions creates an opportunity to use sucrose or other saccharides to selectively elevate heating in specific tissues upon exposure to a radiofrequency field.
Gupta, Anita; Huettner, Daniel P; Dukewich, Matthew
2017-03-01
Patients suffering from osteoarthritis of the knee and patients post total knee arthroplasty often develop refractory, disabling chronic knee pain. Radiofrequency ablation, including conventional, pulsed, and cooled, has recently become more accepted as an interventional technique to manage chronic knee pain in patients who have failed conservative treatment or who are not suitable candidates for surgical treatment. This systematic review aimed to analyze published studies on radiofrequency ablation to provide an overview of the current knowledge regarding variations in procedures, nerve targets, adverse events, and temporal extent of clinical benefit. A systematic review of published studies investigating conventional, pulsed, or cooled radiofrequency ablation in the setting of chronic knee pain. Medline, Google Scholar, and the Cochrane Central Register of Controlled Trials (CENTRAL) databases were reviewed for studies on radiofrequency ablation for patients with chronic knee pain through July 29, 2016. From the studies, the procedural details, outcomes after treatment, follow-up points, and complications were compiled and analyzed in this literature review. Included studies were analyzed for clinical relevance and strength of evidence was graded using either the NHLBI Quality assessment of controlled intervention studies or the NHLBI quality assessment for before-after (pre-post) studies with no control group. Seventeen total publications were identified in the search, including articles investigating conventional, pulsed, or cooled radiofrequency ablation. These studies primarily targeted either the genicular nerves or used an intraarticular approach. Of the studies, 5 were small-sized randomized controlled trials, although one involved diathermy radiofrequency ablation. There were 8 retrospective or prospective case series and 4 case reports. Utilizing the strength of evidence grading, there is a low level of certainty to suggest a superior benefit between targeting the genicular nerve, an intraarticular approach, or targeting the larger nerves such as femoral and tibial nerves. Utilizing the strength of evidence grading, there is a low level of certainty in supporting the superiority of any specific RFA procedure modality. The majority of the studies report positive patient outcomes, but the inconsistent procedural methodology, inconsistent patient assessment measures, and small study sizes limit the applicability of any specific study to clinical practice. While the wide search strategy included a variety of articles, broad conclusions and pooled data could not be obtained based on the studies analyzed. Overall, the studies showed promising results for the treatment of severe chronic knee pain by radiofrequency ablation at up to one year with minimal complications. Numerous studies, however, yielded concerns about procedural protocols, study quality, and patient follow-up. Radiofrequency ablation can offer substantial clinical and functional benefit to patients with chronic knee pain due to osteoarthritis or post total knee arthroplasty.Key words: Radiofrequency ablation, knee osteoarthritis, knee pain, genicular nerve, total knee arthroplasty (TKA), cooled radiofrequency ablation, pulsed radiofrequency ablation.
MRI of the Musculoskeletal System: Advanced Applications using High and Ultrahigh Field MRI.
Alizai, Hamza; Chang, Gregory; Regatte, Ravinder R
2015-09-01
In vivo MRI has revolutionized the diagnosis and treatment of musculoskeletal disorders over the past 3 decades. Traditionally performed at 1.5 T, MRI at higher field strengths offers several advantages over lower field strengths including increased signal-to-noise ratio, higher spatial resolution, improved spectral resolution for spectroscopy, improved sensitivity for X-nucleus imaging, and decreased image acquisition times. However, the physics of imaging at higher field strengths also presents technical challenges. These include B0 and B1+ field inhomogeneity, design and construction of dedicated radiofrequency (RF) coils for use at high field, increased chemical shift and susceptibility artifacts, increased RF energy deposition (specific absorption rate), increased metal artifacts, and changes in relaxation times compared with the lower field scanners. These challenges were overcome in optimizing high-field (HF) (3 T) MRI over a decade ago. HF MRI systems have since gained universal acceptance for clinical musculoskeletal imaging and have also been widely utilized for the study of musculoskeletal anatomy and physiology. Recently there has been an increasing interest in exploring musculoskeletal applications of ultrahigh field (UHF) (7 T) systems. However, technical challenges similar to those encountered when moving from 1.5 T to 3 T have to be overcome to optimize 7 T musculoskeletal imaging. In this narrative review, we discuss the many potential opportunities and technical challenges presented by the HF and UHF MRI systems. We highlight recent developments in in vivo imaging of musculoskeletal tissues that benefit most from HF imaging including cartilage, skeletal muscle, and bone. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Paredes, Ferran; Herrojo, Cristian; Mata-Contreras, Javier; Moras, Miquel; Núñez, Alba; Ramon, Eloi; Martín, Ferran
2018-04-09
A chipless radio-frequency identification (chipless-RFID) and sensing system, where tags are read by proximity (near-field) through a switch, is presented. The tags consist of a set of identical resonant elements (split-ring resonators or SRRs), printed or etched at predefined and equidistant positions, forming a linear chain, each SRR providing a bit of information. The logic state ('1' or '0') associated with each resonator depends on whether it is present or not in the predefined position. The reader is an array of power splitters used to feed a set of SRR-loaded transmission lines (in equal number to the number of resonant elements, or bits, of the tag). The feeding (interrogation) signal is a harmonic (single-tone) signal tuned to a frequency in the vicinity of the fundamental resonance of the SRRs. The set of SRR-loaded lines must be designed so that the corresponding SRRs are in perfect alignment with the SRRs of the tag, provided the tag is positioned on top of the reader. Thus, in a reading operation, as long as the tag is very close to the reader, the SRRs of the tag modify (decrease) the transmission coefficient of the corresponding reader line (through electromagnetic coupling between both SRRs), and the amplitude of the output signal is severely reduced. Therefore, the identification (ID) code of the tag is contained in the amplitudes of the output signals of the SRR-loaded lines, which can be inferred sequentially by means of a switching system. Unlike previous chipless-RFID systems based on near-field and sequential bit reading, the tags in the proposed system can be merely positioned on top of the reader, conveniently aligned, without the need to mechanically place them across the reader. Since tag reading is only possible if the tag is very close to the reader, this system can be also used as a proximity sensor with applications such as target identification. The proposed chipless-RFID and sensing approach is validated by reading a designed 4-bit tag. For identification purposes, this system is of special interest in applications where a low number of bits suffice, and tag reading by proximity is acceptable (or even convenient). Applications mostly related to secure paper, particularly involving a limited number of items (e.g., exams, ballots, etc.), in order to provide authenticity and avoid counterfeiting, are envisaged. As a proximity sensor, the system may be of use in detecting and distinguishing different targets in applications such as smart packaging.
Mata-Contreras, Javier; Moras, Miquel; Ramon, Eloi; Martín, Ferran
2018-01-01
A chipless radio-frequency identification (chipless-RFID) and sensing system, where tags are read by proximity (near-field) through a switch, is presented. The tags consist of a set of identical resonant elements (split-ring resonators or SRRs), printed or etched at predefined and equidistant positions, forming a linear chain, each SRR providing a bit of information. The logic state (‘1’ or ‘0’) associated with each resonator depends on whether it is present or not in the predefined position. The reader is an array of power splitters used to feed a set of SRR-loaded transmission lines (in equal number to the number of resonant elements, or bits, of the tag). The feeding (interrogation) signal is a harmonic (single-tone) signal tuned to a frequency in the vicinity of the fundamental resonance of the SRRs. The set of SRR-loaded lines must be designed so that the corresponding SRRs are in perfect alignment with the SRRs of the tag, provided the tag is positioned on top of the reader. Thus, in a reading operation, as long as the tag is very close to the reader, the SRRs of the tag modify (decrease) the transmission coefficient of the corresponding reader line (through electromagnetic coupling between both SRRs), and the amplitude of the output signal is severely reduced. Therefore, the identification (ID) code of the tag is contained in the amplitudes of the output signals of the SRR-loaded lines, which can be inferred sequentially by means of a switching system. Unlike previous chipless-RFID systems based on near-field and sequential bit reading, the tags in the proposed system can be merely positioned on top of the reader, conveniently aligned, without the need to mechanically place them across the reader. Since tag reading is only possible if the tag is very close to the reader, this system can be also used as a proximity sensor with applications such as target identification. The proposed chipless-RFID and sensing approach is validated by reading a designed 4-bit tag. For identification purposes, this system is of special interest in applications where a low number of bits suffice, and tag reading by proximity is acceptable (or even convenient). Applications mostly related to secure paper, particularly involving a limited number of items (e.g., exams, ballots, etc.), in order to provide authenticity and avoid counterfeiting, are envisaged. As a proximity sensor, the system may be of use in detecting and distinguishing different targets in applications such as smart packaging. PMID:29642560
Optical Measurements of Strong Radio-Frequency Fields Using Rydberg Atoms
NASA Astrophysics Data System (ADS)
Miller, Stephanie Anne
There has recently been an initiative toward establishing atomic measurement standards for field quantities, including radio-frequency, millimeter-wave, and micro-wave electric fields. Current measurement standards are obtained using dipole antennas, which are fundamentally limited in frequency bandwidth (set by the physical size of the antenna) and accuracy (due to the metal perturbing the field during the measurement). Establishing an atomic standard rectifies these problems. My thesis work contributes to an ongoing effort towards establishing the viability of using Rydberg electromagnetically induced transparency (EIT) to perform atom-based measurements of radio-frequency (RF) fields over a wide range of frequencies and field strengths, focusing on strong-field measurements. Rydberg atoms are atoms with an electron excited to a high principal quantum number, resulting in a high sensitivity to an applied field. A model based on Floquet theory is implemented to accurately describe the observed atomic energy level shifts from which information about the field is extracted. Additionally, the effects due to the different electric field domains within the measurement volume are accurately modeled. Absolute atomic measurements of fields up to 296 V/m within a +/-0.35% relative uncertainty are demonstrated. This is the strongest field measured at the time of data publication. Moreover, the uncertainty is over an order of magnitude better than that of current standards. A vacuum chamber setup that I implemented during my graduate studies is presented and its unique components are detailed. In this chamber, cold-atom samples are generated and Rydberg atoms are optically excited within the ground-state sample. The Rydberg ion detection and imaging procedure are discussed, particularly the high magnification that the system provides. By analyzing the position of the ions, the spatial correlation g(2) (r) of Rydberg-atom distributions can be extracted. Aside from ion detection, EIT is implemented in the cold-atom samples. By measuring the timing of the probe photons exiting the EIT medium, the temporal correlation function g(2)(tau) can be extracted, yielding information about the timing between two different arbitrary photons. An experimental goal using this setup is to look at g(2)(tau) in conjunction with g(2)(r) for Rydberg atoms. Progress and preliminary measurements of ion detection and EIT spectra are presented including observed qualitative behaviors.
Mathematical Modeling and Data Analysis of NMR Experiments using Hyperpolarized 13C Metabolites
Pagès, Guilhem; Kuchel, Philip W.
2013-01-01
Rapid-dissolution dynamic nuclear polarization (DNP) has made significant impact in the characterization and understanding of metabolism that occurs on the sub-minute timescale in several diseases. While significant efforts have been made in developing applications, and in designing rapid-imaging radiofrequency (RF) and magnetic field gradient pulse sequences, very few groups have worked on implementing realistic mathematical/kinetic/relaxation models to fit the emergent data. The critical aspects to consider when modeling DNP experiments depend on both nuclear magnetic resonance (NMR) and (bio)chemical kinetics. The former constraints are due to the relaxation of the NMR signal and the application of ‘read’ RF pulses, while the kinetic constraints include the total amount of each molecular species present. We describe the model-design strategy we have used to fit and interpret our DNP results. To our knowledge, this is the first report on a systematic analysis of DNP data. PMID:25114541
47 CFR 2.1093 - Radiofrequency radiation exposure evaluation: portable devices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz,” ANSI/IEEE C95.1-1992... Electromagnetic Fields,” NCRP Report No. 86, Section 17.4.5. Copyright NCRP, 1986, Bethesda, Maryland 20814. SAR... Potentially Hazardous Electromagnetic Fields—RF and Microwave,” IEEE C95.3-1991. (4) For purposes of analyzing...
47 CFR 2.1093 - Radiofrequency radiation exposure evaluation: portable devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz,” ANSI/IEEE C95.1-1992... Electromagnetic Fields,” NCRP Report No. 86, Section 17.4.5. Copyright NCRP, 1986, Bethesda, Maryland 20814. SAR... Potentially Hazardous Electromagnetic Fields—RF and Microwave,” IEEE C95.3-1991. (4) For purposes of analyzing...
Influences of the shielding cylinder on the length of radio-frequency cold atmospheric plasma jets
NASA Astrophysics Data System (ADS)
Li, He-Ping; Li, Jing; Zhang, Xiao-Fei; Guo, Heng; Chen, Jian; Department of Engineering Physics Team
2017-10-01
Cold atmospheric plasma jets driven by a radio frequency power supply contain abundant species and complex chemical reactions, which have wide applications in the fields of materials processing and modifications, food engineering, bio-medical science, etc. Our previous experiments have shown that the total length of a radio-frequency cold atmospheric plasma (RF-CAP) jet can exceed 1 meter with the shielding of a quartz tube. However, the shielding mechanisms of the solid cylinder has not been studied systematically. In this study, a two-dimensional, quasi-steady fluid model is used to investigate the influences of the shielding tube on the length of the RF-CAP jets under different conditions. The simulation results show that the total jet length grows monotonously; while simultaneously, the jet length out of the tube shows a non-monotonic variation trend, with the increase of the tube length, which is in good agreement with the experimental observations. The shielding mechanisms of the solid cylinder on the RF-CAP jet is also discussed in detail based on the modeling results. This work was supported by the National Natural Science Foundation of China (11475103, 21627812), the National Key Research and Development Program of China (2016YFD0102106) and Tsinghua University Initiative Scientific Program (20161080108).
Ion Kinetics in Silane Plasmas
1988-04-20
field and orthogonal to the excite plates. The image current is amplified, digitized, and Fourier analyzed to yield a spectrum of 0 cyclotron...Laboratory (AFWAL/P0OC). 17. COSATI CODES 18. SUBJECT TERMS (Continue on reverse if necessary and identify by block number) FIELD GROUP SUB-GROUP 20 U9 09 03...d.c., microwave, or capacatively coupled, radiofrequency electric fields . Alternatively, hollow cath- ode or electron beam approaches may be employed
Optimization of the generator settings for endobiliary radiofrequency ablation
Barret, Maximilien; Leblanc, Sarah; Vienne, Ariane; Rouquette, Alexandre; Beuvon, Frederic; Chaussade, Stanislas; Prat, Frederic
2015-01-01
AIM: To determine the optimal generator settings for endobiliary radiofrequency ablation. METHODS: Endobiliary radiofrequency ablation was performed in live swine on the ampulla of Vater, the common bile duct and in the hepatic parenchyma. Radiofrequency ablation time, “effect”, and power were allowed to vary. The animals were sacrificed two hours after the procedure. Histopathological assessment of the depth of the thermal lesions was performed. RESULTS: Twenty-five radiofrequency bursts were applied in three swine. In the ampulla of Vater (n = 3), necrosis of the duodenal wall was observed starting with an effect set at 8, power output set at 10 W, and a 30 s shot duration, whereas superficial mucosal damage of up to 350 μm in depth was recorded for an effect set at 8, power output set at 6 W and a 30 s shot duration. In the common bile duct (n = 4), a 1070 μm, safe and efficient ablation was obtained for an effect set at 8, a power output of 8 W, and an ablation time of 30 s. Within the hepatic parenchyma (n = 18), the depth of tissue damage varied from 1620 μm (effect = 8, power = 10 W, ablation time = 15 s) to 4480 μm (effect = 8, power = 8 W, ablation time = 90 s). CONCLUSION: The duration of the catheter application appeared to be the most important parameter influencing the depth of the thermal injury during endobiliary radiofrequency ablation. In healthy swine, the currently recommended settings of the generator may induce severe, supratherapeutic tissue damage in the biliary tree, especially in the high-risk area of the ampulla of Vater. PMID:26566429
A radio-frequency sheath model for complex waveforms
NASA Astrophysics Data System (ADS)
Turner, M. M.; Chabert, P.
2014-04-01
Plasma sheaths driven by radio-frequency voltages occur in contexts ranging from plasma processing to magnetically confined fusion experiments. An analytical understanding of such sheaths is therefore important, both intrinsically and as an element in more elaborate theoretical structures. Radio-frequency sheaths are commonly excited by highly anharmonic waveforms, but no analytical model exists for this general case. We present a mathematically simple sheath model that is in good agreement with earlier models for single frequency excitation, yet can be solved for arbitrary excitation waveforms. As examples, we discuss dual-frequency and pulse-like waveforms. The model employs the ansatz that the time-averaged electron density is a constant fraction of the ion density. In the cases we discuss, the error introduced by this approximation is small, and in general it can be quantified through an internal consistency condition of the model. This simple and accurate model is likely to have wide application.
Risk Analysis for Nonthermal process interventions
USDA-ARS?s Scientific Manuscript database
Over the last few years a number of nonthermal process interventions including ionizing radiation and ultraviolet light, high pressure processing, pulsed-electric and radiofrequency electric fields, microwave and infrared technologies, bacteriophages, etc. have been approved by regulatory agencies, ...
Cytogenetic investigation of subjects professionally exposed to radiofrequency radiation.
Maes, Annemarie; Van Gorp, Urbain; Verschaeve, Luc
2006-03-01
Nowadays, virtually everybody is exposed to radiofrequency radiation (RFR) from mobile phone base station antennas or other sources. At least according to some scientists, this exposure can have detrimental health effects. We investigated cytogenetic effects in peripheral blood lymphocytes from subjects who were professionally exposed to mobile phone electromagnetic fields in an attempt to demonstrate possible RFR-induced genetic effects. These subjects can be considered well suited for this purpose as their RFR exposure is 'normal' though rather high, and definitely higher than that of the 'general population'. The alkaline comet assay, sister chromatid exchange (SCE) and chromosome aberration tests revealed no evidence of RFR-induced genetic effects. Blood cells were also exposed to the well known chemical mutagen mitomycin C in order to investigate possible combined effects of RFR and the chemical. No cooperative action was found between the electromagnetic field exposure and the mutagen using either the comet assay or SCE test.
NASA Astrophysics Data System (ADS)
Carlo, POGGI; Théo, GUILLAUME; Fabrice, DOVEIL; Laurence, CHÉRIGIER-KOVACIC
2018-07-01
The electric field induced Lyman-α emission diagnostic aims to provide a non intrusive and precise measurement of the electric field in plasma, using a beam of hydrogen atoms prepared in the metastable 2s state. The metastable particles are obtained by means of a proton beam extracted from a hydrogen plasma source, and neutralised by interaction with vaporised caesium. When a 2s atom enters a region where an electric field is present, it undergoes a transition to the 2p state (Stark mixing). It then quickly decays to the ground level, emitting Lyman-α radiation, which is collected by a photomultiplier. The 2s\\to 2p transition rate is proportional to the square of the magnitude of the electric field, and depends on the field oscillation frequency (with peaks around 1 GHz). By measuring the intensity of the Lyman-α radiation emitted by the beam it is possible to determine the magnitude of the field in a defined region. In this work, an analysis of the behaviour of the diagnostic under static or radiofrequency electric field is presented. Electric field simulations obtained with a finite element solver of Maxwell equations, combined with theoretical calculations of the Stark mixing transition rate, are used to develop a model for the interpretation of photomultiplier data. This method shows good agreement with experimental results for the static field case, and allows to measure the field magnitude for the oscillating case.
Percutaneous Radiofrequency Ablation of a Small Renal Mass Complicated by Appendiceal Perforation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boone, Judith, E-mail: j.boone@amc.uva.nl; Bex, Axel, E-mail: a.bex@nki.nl; Prevoo, Warner, E-mail: w.prevoo@nki.nl
2012-06-15
Percutaneous radiofrequency ablation (RFA) has gained wide acceptance as nephron-sparing therapy for small renal masses in select patients. Generally, it is a safe procedure with minor morbidity and acceptable short-term oncologic outcome. However, as a result of the close proximity of vital structures, such as the bowel, ureter, and large vessels, to the ablative field, complications regarding these structures may occur. This is the first article describing appendiceal perforation as a complication of computed tomography-guided RFA despite hydrodissection. When performing this innovative and promising procedure one should be aware of the possibility of particular minor and even major complications.
Screen-Printing Fabrication and Characterization of Stretchable Electronics
Suikkola, Jari; Björninen, Toni; Mosallaei, Mahmoud; Kankkunen, Timo; Iso-Ketola, Pekka; Ukkonen, Leena; Vanhala, Jukka; Mäntysalo, Matti
2016-01-01
This article focuses on the fabrication and characterization of stretchable interconnects for wearable electronics applications. Interconnects were screen-printed with a stretchable silver-polymer composite ink on 50-μm thick thermoplastic polyurethane. The initial sheet resistances of the manufactured interconnects were an average of 36.2 mΩ/◽, and half the manufactured samples withstood single strains of up to 74%. The strain proportionality of resistance is discussed, and a regression model is introduced. Cycling strain increased resistance. However, the resistances here were almost fully reversible, and this recovery was time-dependent. Normalized resistances to 10%, 15%, and 20% cyclic strains stabilized at 1.3, 1.4, and 1.7. We also tested the validity of our model for radio-frequency applications through characterization of a stretchable radio-frequency identification tag. PMID:27173424
Mina, Despoina; Sagonas, Kostas; Fragopoulou, Adamantia F; Pafilis, Panayiotis; Skouroliakou, Aikaterini; Margaritis, Lukas H; Tsitsilonis, Ourania E; Valakos, Efstratios D
2016-01-01
During the last three decades, the number of devices that emit non-ionizing electromagnetic radiation (EMR) at the wireless communication spectrum has rapidly increased and possible effects on living organisms have become a major concern. The purpose of this study was to investigate the effects of radiofrequency EMR emitted by a widely used wireless communication device, namely the Digital Enhanced Communication Telephony (DECT) base, on the immune responses of the Aegean wall lizard (Podarcis erhardii). Adult male lizards were exposed 24 h/day for 8 weeks to 1880-1900 MHz DECT base radiation at average electric field intensity of 3.2 V/m. Immune reactivity was assessed using the phytohemagglutinin (PHA) skin swelling and mixed lymphocyte reaction (MLR) tests. Our results revealed a noticeable suppression (approximately 45%) of inflammatory responses in EMR-exposed lizards compared to sham-exposed animals. T cell-mediated responses were marginally affected. Daily radiofrequency EMR exposure seems to affect, at least partially, the immunocompetence of the Aegean wall lizard.
Ellenor, Christopher W; Stang, Pascal P; Etezadi-Amoli, Maryam; Pauly, John M; Scott, Greig C
2015-03-01
The concept of a "radiofrequency safety prescreen" is investigated, wherein dangerous interactions between radiofrequency fields used in MRI, and conductive implants in patients are detected through impedance changes in the radiofrequency coil. The behavior of coupled oscillators is reviewed, and the resulting, observable impedance changes are discussed. A birdcage coil is loaded with a static head phantom and a wire phantom with a wire close to its resonant length, the shape, position, and orientation of which can be changed. Interactions are probed with a current sensor and network analyzer. Impedance spectra show dramatic, unmistakable splitting in cases of strong coupling, and strong correlation is observed between induced current and scattering parameters. The feasibility of a new, low-power prescreening technique has been demonstrated in a simple phantom experiment, which can unambiguously detect resonant interactions between an implanted wire and an imaging coil. A new technique has also been presented which can detect parallel transmit null modes for the wire. © 2014 Wiley Periodicals, Inc.
A two-scale model of radio-frequency electrosurgical tissue ablation
NASA Astrophysics Data System (ADS)
Karaki, Wafaa; Rahul; Lopez, Carlos A.; Borca-Tasciuc, Diana-Andra; De, Suvranu
2017-12-01
Radio-frequency electrosurgical procedures are widely used to simultaneously dissect and coagulate tissue. Experiments suggest that evaporation of cellular and intra-cellular water plays a significant role in the evolution of the temperature field at the tissue level, which is not adequately captured in a single scale energy balance equation. Here, we propose a two-scale model to study the effects of microscale phase change and heat dissipation in response to radiofrequency heating on the tissue level in electrosurgical ablation procedures. At the microscale, the conservation of mass along with thermodynamic and mechanical equilibrium is applied to obtain an equation-of-state relating vapor mass fraction to temperature and pressure. The evaporation losses are incorporated in the macro-level energy conservation and results are validated with mean experimental temperature distributions measured from electrosurgical ablation testing on ex vivo porcine liver at different power settings of the electrosurgical instrument. Model prediction of water loss and its effect on the temperature along with the effect of the mechanical properties on results are evaluated and discussed.
Cutting Edge RFID Technologies for NASA Applications
NASA Technical Reports Server (NTRS)
Fink, Patrick W.
2007-01-01
This viewgraph document reviews the use of Radio-frequency identification (RFID) for NASA applications. Some of the uses reviewed are: inventory management in space; potential RFID uses in a remote human outpost; Ultra-Wideband RFID for tracking; Passive, wireless sensors in NASA applications such as Micrometeoroid impact detection and Sensor measurements in environmental facilities; E-textiles for wireless and RFID.
Qin, Fenju; Yuan, Hongxia; Nie, Jihua; Cao, Yi; Tong, Jian
2014-01-01
To study the effects of nano-selenium (NSe) on cognition performance of mice exposed to 1800 MHz radiofrequency fields (RF). Male mice were randomly divided into four groups, control and nano-Se low, middle and high dose groups (L, M, H). Each group was sub-divided into three groups, RF 0 min, RF 30 min and RF 120 min. Nano-se solution (2, 4 and 8 microg/ml) were administered to mice of L, M, H groups by intra-gastric injection respectively, 0.5 ml/d for 50 days, the conctral group were administered with distilled water. At the 21st day, the mice in RF subgroup were exposed to 208 microW/cm2 1800 MHz radiofrequency fields (0, 30 and 120 min/d respectively) for 30 days. The cognitive ability of the mice were tested with Y-maze. Further, the levels of MDA, GABA, Glu, Ach and the activities of CAT and GSH-Px in cerebra were measured. Significant impairments in learning and memory (P < 0.05) were observed in the RF 120 min group, and with reduction of the Ach level and the activities of CAT and GSH-Px and increase of the content of GABA, Glu and MDA in cerebrum. NSe enhanced cognitive performance of RF mice, decreased GABA, Glu and MDA levels, increased Ach levels, GSH-Px and CAT activities. NSe could improve cognitive impairments of mice exposed to RF, the mechanism of which might involve the increasing antioxidation, decreasing free radical content and the changes of cerebra neurotransmitters.
47 CFR 73.875 - Modification of transmission systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... (2) Those that would cause the transmission system to exceed the equipment performance measurements... radiofrequency radiation guidelines. In addition, applications solely filed pursuant to paragraphs (c)(1) or (c...
Mulier, Stefaan; Jiang, Yansheng; Jamart, Jacques; Wang, Chong; Feng, Yuanbo; Marchal, Guy; Michel, Luc; Ni, Yicheng
2015-01-01
Size and geometry of the ablation zone obtained by currently available radiofrequency (RF) electrodes is highly variable. Reliability might be improved by matrix radiofrequency ablation (MRFA), in which the whole tumour volume is contained within a cage of x × y parallel electrodes. The aim of this study was to optimise the smallest building block for matrix radiofrequency ablation: a recently developed bipolar 2 × 2 electrode system. In ex vivo bovine liver, the parameters of the experimental set-up were changed one by one. In a second step, a finite element method (FEM) modelling of the experiment was performed to better understand the experimental findings. The optimal power to obtain complete ablation in the shortest time was 50-60 W. Performing an ablation until impedance rise was superior to ablation for a fixed duration. Increasing electrode diameter improved completeness of ablation due to lower temperature along the electrodes. A chessboard pattern of electrode polarity was inferior to a row pattern due to an electric field void in between the electrodes. Variability of ablation size was limited. The FEM correctly simulated and explained the findings in ex vivo liver. These experiments and FEM modelling allowed a better insight in the factors influencing the ablation zone in a bipolar 2 × 2 electrode RF system. With optimal parameters, complete ablation was obtained quickly and with limited variability. This knowledge will be useful to build a larger system with x × y electrodes for MRFA.
Cesar, D; Maxson, J; Musumeci, P; Sun, Y; Harrison, J; Frigola, P; O'Shea, F H; To, H; Alesini, D; Li, R K
2016-07-08
We present the results of an experiment where a short focal length (∼1.3 cm), permanent magnet electron lens is used to image micron-size features (of a metal sample) with a single shot from an ultrahigh brightness picosecond-long 4 MeV electron beam emitted by a radio-frequency photoinjector. Magnification ratios in excess of 30× were obtained using a triplet of compact, small gap (3.5 mm), Halbach-style permanent magnet quadrupoles with nearly 600 T/m field gradients. These results pave the way towards single-shot time-resolved electron microscopy and open new opportunities in the applications of high brightness electron beams.
Radiofrequency denervation of the hip joint for pain management: case report and literature review.
Gupta, Gaurav; Radhakrishna, Mohan; Etheridge, Paul; Besemann, Markus; Finlayson, Robert J
2014-01-01
A 55-year-old male presented with severe pain and functional limitations as a result of left hip osteoarthritis. He had failed multiple treatments while waiting for a hip arthroplasty, including physical therapy, medications, and various intra-articular injections. Thermal radiofrequency lesioning of the obturator and femoral articular branches to the hip joint was offered in the interim. To our knowledge, this is the first report to describe an inferior-lateral approach for lesioning the obturator branch, the clinical application of successive lesions to increase denervation area, and outcomes in a patient receiving a second treatment with previously good results. To discuss relevant and technical factors for this specific case, we reviewed previous literature on hip joint radiofrequency and critically evaluated previous anatomic studies in the context of radiofrequency. The first treatment provided significant benefit for a period of 6 months. A second treatment was employed providing only mild to moderate benefit until his joint replacement surgery 4 months later. Literature review revealed studies of low quality secondary to small sample sizes, patient selection methodology, inclusion of patients with heterogenous etiologies for pain, variable needle placement techniques, and lack of measurement of functional outcomes. Case report and low quality studies in existing literature. Hip joint radiofrequency denervation is a promising avenue for adjunctive treatment of hip pain. Further cadaveric studies are required to clarify a multitude of technical parameters. Once these are well defined, future clinical studies should consider pain, functional, and economic outcomes in their design.
Initial experience of EUS-guided radiofrequency ablation of unresectable pancreatic cancer.
Song, Tae Jun; Seo, Dong Wan; Lakhtakia, Sundeep; Reddy, Nageshwar; Oh, Dong Wook; Park, Do Hyun; Lee, Sang Soo; Lee, Sung Koo; Kim, Myung-Hwan
2016-02-01
Radiofrequency ablation (RFA) has been used as a valuable treatment modality for various unresectable malignancies. EUS-guided radiofrequency ablation (EUS-RFA) of the porcine pancreas was reported to be feasible and safe in our previous study, suggesting that EUS-RFA may be applicable as an adjunct and effective alternative treatment method for unresectable pancreatic cancer. This study aimed to assess the technical feasibility and safety of EUS-RFA for unresectable pancreatic cancer. An 18-gauge endoscopic RFA electrode and a radiofrequency generator were used for the procedure. The length of the exposed tip of the RFA electrode was 10 mm. After insertion of the RFA electrode into the mass, the radiofrequency generator was activated to deliver 20 to 50 W ablation power for 10 seconds. Depending on tumor size, the procedure was repeated to sufficiently cover the tumor. EUS-RFA was performed successfully in all 6 patients (median age 62 years, range 43-73 years). Pancreatic cancer was located in the head (n = 4) or body (n = 2) of the pancreas. The median diameter of masses was 3.8 cm (range 3cm-9cm). Four patients had stage 3 disease, and 2 patients had stage 4 disease. After the procedure, 2 patients experienced mild abdominal pain, but there were no other adverse events such as pancreatitis or bleeding. EUS-RFA could be a technically feasible and safe option for patients with unresectable pancreatic cancer. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Alternative food safety intervention technologies: flash pasteurization of finfish
USDA-ARS?s Scientific Manuscript database
Alternative nonthermal and thermal food safety interventions are gaining acceptance by the food processing industry and consumers. These technologies include high pressure processing, ultraviolet and pulsed light, ionizing radiation, pulsed and radiofrequency electric fields, cold atmospheric plasm...
Large-area graphene for sensor applications
NASA Astrophysics Data System (ADS)
Snow, Eric S.
2010-04-01
Graphene represents an important new material with potential Department of Defense sensor applications. At the Naval Research Laboratory we have developed three techniques to produce large-area graphene films. We have used this material to construct chemical and radio-frequency electromagnetic sensors. Here we report the initial results of this effort.
NASA Astrophysics Data System (ADS)
Liu, Dan; Li, Congsheng; Kang, Yangyang; Zhou, Zhou; Xie, Yi; Wu, Tongning
2017-09-01
In this study, the plane wave exposure of an infant to radiofrequency electromagnetic fields of 3.5 GHz was numerically analyzed to investigate the unintentional electromagnetic field (EMF) exposure of fifth generation (5G) signals during field test. The dosimetric influence of age-dependent dielectric properties and the influence of an adult body were evaluated using an infant model of 12 month old and an adult female model. The results demonstrated that the whole body-averaged specific absorption rate (WBASAR) was not significantly affected by age-dependent dielectric properties and the influence of the adult body did not enhance WBASAR. Taking the magnitude of the in situ
Radio-frequency and microwave energies, magnetic and electric fields
NASA Technical Reports Server (NTRS)
Michaelson, S. M.
1975-01-01
The biological effects of radio frequency, including microwave, radiation are considered. Effects on body temperature, the eye, reproductive systems, internal organs, blood cells, the cardiovascular system, and the central nervous system are included. Generalized effects of electric and magnetic fields are also discussed. Experimentation with animals and clinical studies on humans are cited, and possible mechanisms of the effects observed are suggested.
Radiofrequency pulse design using nonlinear gradient magnetic fields.
Kopanoglu, Emre; Constable, R Todd
2015-09-01
An iterative k-space trajectory and radiofrequency (RF) pulse design method is proposed for excitation using nonlinear gradient magnetic fields. The spatial encoding functions (SEFs) generated by nonlinear gradient fields are linearly dependent in Cartesian coordinates. Left uncorrected, this may lead to flip angle variations in excitation profiles. In the proposed method, SEFs (k-space samples) are selected using a matching pursuit algorithm, and the RF pulse is designed using a conjugate gradient algorithm. Three variants of the proposed approach are given: the full algorithm, a computationally cheaper version, and a third version for designing spoke-based trajectories. The method is demonstrated for various target excitation profiles using simulations and phantom experiments. The method is compared with other iterative (matching pursuit and conjugate gradient) and noniterative (coordinate-transformation and Jacobian-based) pulse design methods as well as uniform density spiral and EPI trajectories. The results show that the proposed method can increase excitation fidelity. An iterative method for designing k-space trajectories and RF pulses using nonlinear gradient fields is proposed. The method can either be used for selecting the SEFs individually to guide trajectory design, or can be adapted to design and optimize specific trajectories of interest. © 2014 Wiley Periodicals, Inc.
Hiscock, Hamish G; Mouritsen, Henrik; Manolopoulos, David E; Hore, P J
2017-10-03
The radical-pair mechanism has been put forward as the basis of the magnetic compass sense of migratory birds. Some of the strongest supporting evidence has come from behavioral experiments in which birds exposed to weak time-dependent magnetic fields lose their ability to orient in the geomagnetic field. However, conflicting results and skepticism about the requirement for abnormally long quantum coherence lifetimes have cast a shroud of uncertainty over these potentially pivotal studies. Using a recently developed computational approach, we explore the effects of various radiofrequency magnetic fields on biologically plausible radicals within the theoretical framework of radical-pair magnetoreception. We conclude that the current model of radical-pair magnetoreception is unable to explain the findings of the reported behavioral experiments. Assuming that an unknown mechanism amplifies the predicted effects, we suggest experimental conditions that have the potential to distinguish convincingly between the two distinct families of radical pairs currently postulated as magnetic compass sensors. We end by making recommendations for experimental protocols that we hope will increase the chance that future experiments can be independently replicated. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Matikka Virtanen, H; Keshvari, J; Lappalainen, R
2010-10-07
Along with increased use of wireless communication devices operating in the radiofrequency (RF) range, concern has been raised about the related possible health risks. Among other concerns, the interaction of medical implants and RF devices has been studied in order to assure the safety of implant carriers under various exposure conditions. In the RF range, the main established quantitative effect of electromagnetic (EM) fields on biological tissues is heating due to vibrational movements of water molecules. The temperature changes induced in tissues also constitute the basis for the setting of RF exposure limits and recommendations. In this study, temperature changes induced by electromagnetic field enhancements near passive metallic implants have been simulated in the head region. Furthermore, the effect of the implant material on the induced temperature change was evaluated using clinically used metals with the highest and the lowest thermal conductivities. In some cases, remarkable increases in maximum temperatures of tissues (as much as 8 °C) were seen in the near field with 1 W power level whereas at lower power levels significant temperature increases were not observed.
Tomanova, K; Vacha, M
2016-06-01
Studies on weak man-made radiofrequency (RF) electromagnetic fields affecting animal magnetoreception aim for a better understanding of the reception mechanism and also point to a new phenomenon having possible consequences in ecology and environmental protection. RF impacts on magnetic compasses have recently been demonstrated in migratory birds and other vertebrates. We set out to investigate the effect of RF on the magnetic orientation of the Antarctic krill species Gondogeneia antarctica, a small marine crustacean widespread along the Antarctic littoral line. Here, we show that upon release, G. antarctica (held under laboratory conditions) escaped in the magnetically seaward direction along the magnetic sea-land axis (y-axis) of the home beach. However, the animals were disoriented after being exposed to RF. Orientation was lost not only in an RF field with a magnetic flux density of 20 nT, as expected according to the literature, but even under the 2 nT originally intended as a control. Our results extend recent findings of the extraordinary sensitivity of animal magnetoreception to weak RF fields in marine invertebrates. © 2016. Published by The Company of Biologists Ltd.
Pushing the limits of radiofrequency (RF) neuronal telemetry
Yousefi, Tara; Diaz, Rodolfo E.
2015-01-01
In a previous report it was shown that the channel capacity of an in vivo communication link using microscopic antennas at radiofrequency is severely limited by the requirement not to damage the tissue surrounding the antennas. For dipole-like antennas the strong electric field dissipates too much power into body tissues. Loop-type antennas have a strong magnetic near field and so dissipate much less power into the surrounding tissues but they require such a large current that the antenna temperature is raised to the thermal damage threshold of the tissue. The only solution was increasing the antenna size into hundreds of microns, which makes reporting on an individual neuron impossible. However, recently demonstrated true magnetic antennas offer an alternative not covered in the previous report. The near field of these antennas is dominated by the magnetic field yet they don’t require large currents. Thus they combine the best characteristics of dipoles and loops. By calculating the coupling between identical magnetic antennas inside a model of the body medium we show an increase in the power transfer of up to 8 orders of magnitude higher than could be realized with the loops and dipoles, making the microscopic RF in-vivo transmitting antenna possible. PMID:26035824
NASA Astrophysics Data System (ADS)
Matikka (formerly Virtanen, H.; Keshvari, J.; Lappalainen, R.
2010-10-01
Along with increased use of wireless communication devices operating in the radiofrequency (RF) range, concern has been raised about the related possible health risks. Among other concerns, the interaction of medical implants and RF devices has been studied in order to assure the safety of implant carriers under various exposure conditions. In the RF range, the main established quantitative effect of electromagnetic (EM) fields on biological tissues is heating due to vibrational movements of water molecules. The temperature changes induced in tissues also constitute the basis for the setting of RF exposure limits and recommendations. In this study, temperature changes induced by electromagnetic field enhancements near passive metallic implants have been simulated in the head region. Furthermore, the effect of the implant material on the induced temperature change was evaluated using clinically used metals with the highest and the lowest thermal conductivities. In some cases, remarkable increases in maximum temperatures of tissues (as much as 8 °C) were seen in the near field with 1 W power level whereas at lower power levels significant temperature increases were not observed.
Coal thickness gauge using RRAS techniques, part 1. [radiofrequency resonance absorption
NASA Technical Reports Server (NTRS)
Rollwitz, W. L.; King, J. D.
1978-01-01
A noncontacting sensor having a measurement range of 0 to 6 in or more, and with an accuracy of 0.5 in or better is needed to control the machinery used in modern coal mining so that the thickness of the coal layer remaining over the rock is maintained within selected bounds. The feasibility of using the radiofrequency resonance absorption (RRAS) techniques of electron magnetic resonance (EMR) and nuclear magnetic resonance (NMR) as the basis of a coal thickness gauge is discussed. The EMR technique was found, by analysis and experiments, to be well suited for this application.
Non-Destructive Testing with Atmospheric Pressure Radio-Frequency Plasma
NASA Astrophysics Data System (ADS)
May, A.; Andarawis, E.
2007-03-01
We summarize our recent work using radio-frequency (RF) atmospheric pressure plasma (APP) for non-destructive evaluation (NDE), specifically for: (1) Clearance sensing (0-5mm) on rotating components, and (2) Generation of broadband ultrasound in air at 900kHz. RF-APP showed potential in both of these common NDE requirements, but further work is required to better characterize and optimize the performance of the new techniques. Application of RF-APP to other NDE disciplines, such as plasma spectroscopy and gas flow measurement, is also likely to be advantageous, especially in harsh environments where existing approaches are prohibitively expensive or complex.
Radiofrequency radiation injures trees around mobile phone base stations.
Waldmann-Selsam, Cornelia; Balmori-de la Puente, Alfonso; Breunig, Helmut; Balmori, Alfonso
2016-12-01
In the last two decades, the deployment of phone masts around the world has taken place and, for many years, there has been a discussion in the scientific community about the possible environmental impact from mobile phone base stations. Trees have several advantages over animals as experimental subjects and the aim of this study was to verify whether there is a connection between unusual (generally unilateral) tree damage and radiofrequency exposure. To achieve this, a detailed long-term (2006-2015) field monitoring study was performed in the cities of Bamberg and Hallstadt (Germany). During monitoring, observations and photographic recordings of unusual or unexplainable tree damage were taken, alongside the measurement of electromagnetic radiation. In 2015 measurements of RF-EMF (Radiofrequency Electromagnetic Fields) were carried out. A polygon spanning both cities was chosen as the study site, where 144 measurements of the radiofrequency of electromagnetic fields were taken at a height of 1.5m in streets and parks at different locations. By interpolation of the 144 measurement points, we were able to compile an electromagnetic map of the power flux density in Bamberg and Hallstadt. We selected 60 damaged trees, in addition to 30 randomly selected trees and 30 trees in low radiation areas (n=120) in this polygon. The measurements of all trees revealed significant differences between the damaged side facing a phone mast and the opposite side, as well as differences between the exposed side of damaged trees and all other groups of trees in both sides. Thus, we found that side differences in measured values of power flux density corresponded to side differences in damage. The 30 selected trees in low radiation areas (no visual contact to any phone mast and power flux density under 50μW/m 2 ) showed no damage. Statistical analysis demonstrated that electromagnetic radiation from mobile phone masts is harmful for trees. These results are consistent with the fact that damage afflicted on trees by mobile phone towers usually start on one side, extending to the whole tree over time. Copyright © 2016 Elsevier B.V. All rights reserved.
Xu, Junxia; Huang, Yingqun; Cai, Hongbin; Qi, Yue; Jia, Nan; Shen, Weifeng; Lin, Jinxiu; Peng, Feng; Niu, Wenquan
2014-01-01
Objective Currently radiofrequency and cryoballoon ablations are the two standard ablation systems used for catheter ablation of atrial fibrillation; however, there is no universal consensus on which ablation is the optimal choice. We therefore sought to undertake a meta-analysis with special emphases on comparing the efficacy and safety between cryoballoon and radiofrequency ablations by synthesizing published clinical trials. Methods and Results Articles were identified by searching the MEDLINE and EMBASE databases before September 2013, by reviewing the bibliographies of eligible reports, and by consulting with experts in this field. Data were extracted independently and in duplicate. There were respectively 469 and 635 patients referred for cryoballoon and radiofrequency ablations from 14 qualified clinical trials. Overall analyses indicated that cryoballoon ablation significantly reduced fluoroscopic time and total procedure time by a weighted mean of 14.13 (95% confidence interval [95% CI]: 2.82 to 25.45; P = 0.014) minutes and 29.65 (95% CI: 8.54 to 50.77; P = 0.006) minutes compared with radiofrequency ablation, respectively, whereas ablation time in cryoballoon ablation was nonsignificantly elongated by a weighted mean of 11.66 (95% CI: −10.71 to 34.04; P = 0.307) minutes. Patients referred for cryoballoon ablation had a high yet nonsignificant success rate of catheter ablation compared with cryoballoon ablation (odds ratio; 95% CI; P: 1.34; 0.53 to 3.36; 0.538), and cryoballoon ablation was also found to be associated with the relatively low risk of having recurrent atrial fibrillation (0.75; 0.3 to 1.88; 0.538) and major complications (0.46; 0.11 to 1.83; 0.269). There was strong evidence of heterogeneity and low probability of publication bias. Conclusion Our findings demonstrate greater improvement in fluoroscopic time and total procedure duration for atrial fibrillation patients referred for cryoballoon ablation than those for radiofrequency ablation. PMID:24587324
Murbach, Manuel; Neufeld, Esra; Kainz, Wolfgang; Pruessmann, Klaas P; Kuster, Niels
2014-02-01
Radiofrequency energy deposition in magnetic resonance imaging must be limited to prevent excessive heating of the patient. Correlations of radiofrequency absorption with large-scale anatomical features (e.g., height) are investigated in this article. The specific absorption rate (SAR), as the pivotal parameter for quantifying absorbed radiofrequency, increases with the radial dimension of the patient and therefore with the large-scale anatomical properties. The absorbed energy in six human models has been modeled in different Z-positions (head to knees) within a 1.5T bodycoil. For a fixed B1+ incident field, the whole-body SAR can be up to 2.5 times higher (local SAR up to seven times) in obese adult models compared to children. If the exposure is normalized to 4 W/kg whole-body SAR, the local SAR can well-exceed the limits for local transmit coils and shows intersubject variations of up to a factor of three. The correlations between anatomy and induced local SAR are weak for normalized exposure, but strong for a fixed B1+ field, suggesting that anatomical properties could be used for fast SAR predictions. This study demonstrates that a representative virtual human population is indispensable for the investigation of local SAR levels. Copyright © 2013 Wiley Periodicals, Inc.
Kang, Diana; Han, Julia; Neuberger, Molly M; Moy, M Louis; Wallace, Sheila A; Alonso-Coello, Pablo; Dahm, Philipp
2015-03-18
Transurethral radiofrequency collagen denaturation is a relatively novel, minimally invasive device-based intervention used to treat individuals with urinary incontinence (UI). No systematic review of the evidence supporting its use has been published to date. To evaluate the efficacy of transurethral radiofrequency collagen denaturation, compared with other interventions, in the treatment of women with UI.Review authors sought to compare the following.• Transurethral radiofrequency collagen denaturation versus no treatment/sham treatment.• Transurethral radiofrequency collagen denaturation versus conservative physical treatment.• Transurethral radiofrequency collagen denaturation versus mechanical devices (pessaries for UI).• Transurethral radiofrequency collagen denaturation versus drug treatment.• Transurethral radiofrequency collagen denaturation versus injectable treatment for UI.• Transurethral radiofrequency collagen denaturation versus other surgery for UI. We conducted a systematic search of the Cochrane Incontinence Group Specialised Register (searched 19 December 2014), EMBASE and EMBASE Classic (January 1947 to 2014 Week 50), Google Scholar and three trials registries in December 2014, along with reference checking. We sought to identify unpublished studies by handsearching abstracts of major gynaecology and urology meetings, and by contacting experts in the field and the device manufacturer. Randomised and quasi-randomised trials of transurethral radiofrequency collagen denaturation versus no treatment/sham treatment, conservative physical treatment, mechanical devices, drug treatment, injectable treatment for UI or other surgery for UI in women were eligible. We screened search results and selected eligible studies for inclusion. We assessed risk of bias and analysed dichotomous variables as risk ratios (RRs) with 95% confidence intervals (CIs) and continuous variables as mean differences (MDs) with 95% CIs. We rated the quality of evidence using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach. We included in the analysis one small sham-controlled randomised trial of 173 women performed in the United States. Participants enrolled in this study had been diagnosed with stress UI and were randomly assigned to transurethral radiofrequency collagen denaturation (treatment) or a sham surgery using a non-functioning catheter (no treatment). Mean age of participants in the 12-month multi-centre trial was 50 years (range 22 to 76 years).Of three patient-important primary outcomes selected for this systematic review, the number of women reporting UI symptoms after intervention was not reported. No serious adverse events were reported for the transurethral radiofrequency collagen denaturation arm or the sham treatment arm during the 12-month trial. Owing to high risk of bias and imprecision, we downgraded the quality of evidence for this outcome to low. The effect of transurethral radiofrequency collagen denaturation on the number of women with an incontinence quality of life (I-QOL) score improvement ≥ 10 points at 12 months was as follows: RR 1.11, 95% CI 0.77 to 1.62; participants = 142, but the confidence interval was wide. For this outcome, the quality of evidence was also low as the result of high risk of bias and imprecision.We found no evidence on the number of women undergoing repeat continence surgery. The risk of other adverse events (pain/dysuria (RR 5.73, 95% CI 0.75 to 43.70; participants = 173); new detrusor overactivity (RR 1.36, 95% CI 0.63 to 2.93; participants = 173); and urinary tract infection (RR 0.95, 95% CI 0.24 to 3.86; participants = 173) could not be established reliably as the trial was small. Evidence was insufficient for assessment of whether use of transurethral radiofrequency collagen denaturation was associated with an increased rate of urinary retention, haematuria and hesitancy compared with sham treatment in 173 participants. The GRADE quality of evidence for all other adverse events with available evidence was low as the result of high risk of bias and imprecision.We found no evidence to inform comparisons of transurethral radiofrequency collagen denaturation with conservative physical treatment, mechanical devices, drug treatment, injectable treatment for UI or other surgery for UI. It is not known whether transurethral radiofrequency collagen denaturation, as compared with sham treatment, improves patient-reported symptoms of UI. Evidence is insufficient to show whether the procedure improves disease-specific quality of life. Evidence is also insufficient to show whether the procedure causes serious adverse events or other adverse events in comparison with sham treatment, and no evidence was found for comparison with any other method of treatment for UI.
Kim, Miri; Lim, Jihong; Bae, Jung Min; Park, Hyun Jeong
2017-11-01
Various radiofrequency (RF) devices are used to treat skin laxity and face contouring, but few studies have examined ultrahigh-frequency (UHF) electric field (40.68 MHz) RF devices. To evaluate the efficacy and safety of a UHF electric field (40.68 MHz) RF device for skin tightening and face contouring. Ten patients each underwent four sessions of UHF electric field RF device treatment at 2-week intervals. Clinical improvement was evaluated with the patient satisfaction score using a six-point scale, and clinical photographs taken at every visit and 2 months after the RF treatment were assessed. Skin biopsies were obtained from one patient before the first treatment and immediately after the last treatment. Adverse reactions were recorded at every follow-up visit. All patients were women with a mean age of 51.7 ± 7.2 years. The mean satisfaction score was 4.5 ± 0.9 immediately after the last treatment session. Cheek, jawline, and neck enhancement and tightening were apparent in all patients. Side effects were minimal, and there were no burns or major complications. The UHF electric field RF device was effective for skin tightening and facial contouring, without significant adverse reactions.
Review of inductively coupled plasmas: Nano-applications and bistable hysteresis physics
NASA Astrophysics Data System (ADS)
Lee, Hyo-Chang
2018-03-01
Many different gas discharges and plasmas exhibit bistable states under a given set of conditions, and the history-dependent hysteresis that is manifested by intensive quantities of the system upon variation of an external parameter has been observed in inductively coupled plasmas (ICPs). When the external parameters (such as discharge powers) increase, the plasma density increases suddenly from a low- to high-density mode, whereas decreasing the power maintains the plasma in a relatively high-density mode, resulting in significant hysteresis. To date, a comprehensive description of plasma hysteresis and a physical understanding of the main mechanism underlying their bistability remain elusive, despite many experimental observations of plasma bistability conducted under radio-frequency ICP excitation. This fundamental understanding of mode transitions and hysteresis is essential and highly important in various applied fields owing to the widespread use of ICPs, such as semiconductor/display/solar-cell processing (etching, deposition, and ashing), wireless light lamp, nanostructure fabrication, nuclear-fusion operation, spacecraft propulsion, gas reformation, and the removal of hazardous gases and materials. If, in such applications, plasma undergoes a mode transition and hysteresis occurs in response to external perturbations, the process result will be strongly affected. Due to these reasons, this paper comprehensively reviews both the current knowledge in the context of the various applied fields and the global understanding of the bistability and hysteresis physics in the ICPs. At first, the basic understanding of the ICP is given. After that, applications of ICPs to various applied fields of nano/environmental/energy-science are introduced. Finally, the mode transition and hysteresis in ICPs are studied in detail. This study will show the fundamental understanding of hysteresis physics in plasmas and give open possibilities for applications to various applied fields to find novel control knob and optimizing processing conditions.
Development and validation of nonthermal and advanced thermal food safety intervention technologies
USDA-ARS?s Scientific Manuscript database
Alternative nonthermal and thermal food safety interventions are gaining acceptance by the food processing industry and consumers. These technologies include high pressure processing, ultraviolet and pulsed light, ionizing radiation, pulsed and radiofrequency electric fields, cold atmospheric plasm...
USAFSAM Review and Analysis of Radiofrequency Radiation Bioeffects Literature: Second Report.
1982-05-01
10 Cellular 11 Mechanisms of interaction 12 Environmental 13 Medical applications 14 Review 15 Ecological 16 Physical methods/dosimetry 17 Other 18...APPLICATIONS List of Analyses ......... .................... 137 (14) REVIEW List of Analyses ......... .................... 138 (16) PHYSICAL METHODS/DOSIMETRY...physiological 10 Cellular 11 Mechanisms of interaction 12 Environmental 13 Medical applications 14 Review 15 Ecological 16 Physical methods/dosimetry 17
[Current situation and thoughts on radiofrequency ablation in the treatment of thyroid cancers].
Zhang, H; Dong, W W
2017-08-01
Radiofrequency ablation (RFA) was originally used primarily for the treatment of regional metastatic lymph nodes from recurrent thyroid cancers in the field of thyroid surgery. In recent years it is gradually used to treat a part of benign thyroid nodules. However, the domestic issues resulting from indiscriminately enlarged RFA indication and lack of standardization of therapy become more and more prominent, including initial treatment of operable thyroid cancers by RFA, which is against by the current consensus about RFA for patients with thyroid nodules and management guidelines for patients with thyroid cancers. Therefore, RFA should be avoided for initial treatment of operable thyroid cancers before the introduction of guidelines based on evidence-based medicine.
Baba, Takashi; Campbell, J. Larry; Le Blanc, J. C. Yves; Baker, Paul R. S.; Hager, James W.; Thomson, Bruce A.
2017-01-01
Collision-induced dissociation (CID) is the most common tool for molecular analysis in mass spectrometry to date. However, there are difficulties associated with many applications because CID does not provide sufficient information to permit details of the molecular structures to be elucidated, including post-translational-modifications in proteomics, as well as isomer differentiation in metabolomics and lipidomics. To face these challenges, we are developing fast electron-based dissociation devices using a novel radio-frequency ion trap (i.e., a branched ion trap). These devices have the ability to perform electron capture dissociation (ECD) on multiply protonated peptide/proteins; in addition, the electron impact excitation of ions from organics (EIEIO) can be also performed on singly charged molecules using such a device. In this article, we review the development of this technology, in particular on how reaction speed for EIEIO analyses on singly charged ions can be improved. We also overview some unique, recently reported applications in both lipidomics and glycoproteomics. PMID:28630811
Baba, Takashi; Campbell, J Larry; Le Blanc, J C Yves; Baker, Paul R S; Hager, James W; Thomson, Bruce A
2017-01-01
Collision-induced dissociation (CID) is the most common tool for molecular analysis in mass spectrometry to date. However, there are difficulties associated with many applications because CID does not provide sufficient information to permit details of the molecular structures to be elucidated, including post-translational-modifications in proteomics, as well as isomer differentiation in metabolomics and lipidomics. To face these challenges, we are developing fast electron-based dissociation devices using a novel radio-frequency ion trap ( i.e. , a branched ion trap). These devices have the ability to perform electron capture dissociation (ECD) on multiply protonated peptide/proteins; in addition, the electron impact excitation of ions from organics (EIEIO) can be also performed on singly charged molecules using such a device. In this article, we review the development of this technology, in particular on how reaction speed for EIEIO analyses on singly charged ions can be improved. We also overview some unique, recently reported applications in both lipidomics and glycoproteomics.
Resonant-cavity antenna for plasma heating
Perkins, F.W. Jr.; Chiu, S.C.; Parks, P.; Rawls, J.M.
1984-01-10
This invention relates generally to a method and apparatus for transferring energy to a plasma immersed in a magnetic field, and relates particularly to an apparatus for heating a plasma of low atomic number ions to high temperatures by transfer of energy to plasma resonances, particularly the fundamental and harmonics of the ion cyclotron frequency of the plasma ions. This invention transfers energy from an oscillating radio-frequency field to a plasma resonance of a plasma immersed in a magnetic field.
The role of radiofrequency surgery in the treatment of hemorrhoidal disease.
Filingeri, V; Bellini, M I; Gravante, G
2012-04-01
In this article we reported results obtained in our previous studies concerning application of radiofrequency (RF) in proctology and in particular for hemorrhoids treatment. We compared radiofrequency submucosal hemorrhoidectomy (RSH) and conventional Parks' hemorrhoidectomy (CPH) (group 1), radiofrequency open hemorrhoidectomy (ROH) and Milligan-Morgan hemorrhoidectomy (MMH) (group 2), radiofrequency closed hemorrhoidectomy (RCH) and Ferguson hemorrhoidectomy (FH) (group 3), combined hemorrhoidal radiocoagulation (CHR) and rubber band ligation (RBL) (group 4). In this work primary endpoints were determined as evaluation of the grade of pain felt immediately after the procedure and at the first evacuation, bleeding, operation time, readmission to work, incidence of failures and patient's satisfaction. Group 1 - In comparison to Parks' technique, use of radiofrequency scalpel reduced mean operation time (61.2 min, range 50-75, vs. 37.4 min, range 30-51; p < 0.05), first postoperative day pain score (5.9, range 3-10, vs. 4.0, range 1-10; p < 0.05), pain score at first evacuation (5.7, range 2-10, vs 4.2, range 1-8; p < 0.05) and pain score on postoperative days (3.6, range 1-9, vs. 2.8, range 1-8; p < 0.05). Group 2 - Results show a substantial similarity between these techniques, however the procedure lasted 7 minutes less with RF scalpel (18.6 min, range 16-21, vs. 25.55 min, range 20-30; p < 0.05). Group 3 - Patients treated with RF showed significant reduction in surgical time (23 min, range 21-31, vs. 33 min, range 24-35; p < 0.01), in pain at 1st post-operative day (VAS score 3.4 +/- 1.3 vs. 4.8 +/- 1.0; p < 0.05) and at the first evacuation (3.4 +/- 1.0 vs. 5.0 +/- 0.8; p < 0.05). Group 4 - The study confirmed validity of both the used techniques, however CHR seems to allow a reduction in incidence of failures. Results obtained from radiofrequency surgery compared with those achieved with classic surgery for hemorrhoidal disease show in the majority of cases that radiosurgery facilitates, accelerates and improves surgical procedures.
CALCIUM RELEASE FROM NERVOUS TISSUE - EXPERIMENTAL RESULTS AND POSSIBLE MECHANISMS
The research discussed in this paper was first conceived following a report by Bawin et al (1975) which demonstrated that amplitude-modulated radiofrequency (RF) fields could preferentially cause a biochemical change in isolated brain tissue depending on the specific frequency of...
Directed Energy Non-lethal Weapons
2010-06-16
technologies that alter skeletal muscle contraction and/or neural functioning (i.e., neurosecretion) via radiofrequency (RF)/microwave (MW...chromaffin cells and 2) completion of studies on the effect of 0.75 to 1 GHz RF fields on skeletal muscle contraction , using in each study fixed
Minami, Yasunori; Kitai, Satoshi; Kudo, Masatoshi
2012-03-01
Virtual CT sonography using magnetic navigation provides cross sectional images of CT volume data corresponding to the angle of the transducer in the magnetic field in real-time. The purpose of this study was to clarify the value of this virtual CT sonography for treatment response of radiofrequency ablation for hepatocellular carcinoma. Sixty-one patients with 88 HCCs measuring 0.5-1.3 cm (mean±SD, 1.0±0.3 cm) were treated by radiofrequency ablation. For early treatment response, dynamic CT was performed 1-5 days (median, 2 days). We compared early treatment response between axial CT images and multi-angle CT images using virtual CT sonography. Residual tumor stains on axial CT images and multi-angle CT images were detected in 11.4% (10/88) and 13.6% (12/88) after the first session of RFA, respectively (P=0.65). Two patients were diagnosed as showing hyperemia enhancement after the initial radiofrequency ablation on axial CT images and showed local tumor progression shortly because of unnoticed residual tumors. Only virtual CT sonography with magnetic navigation retrospectively showed the residual tumor as circular enhancement. In safety margin analysis, 10 patients were excluded because of residual tumors. The safety margin more than 5 mm by virtual CT sonographic images and transverse CT images were determined in 71.8% (56/78) and 82.1% (64/78), respectively (P=0.13). The safety margin should be overestimated on axial CT images in 8 nodules. Virtual CT sonography with magnetic navigation was useful in evaluating the treatment response of radiofrequency ablation therapy for hepatocellular carcinoma. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Harth, Yoram; Frank, Ido
2013-12-01
Microneedle radiofrequency is a novel method that allows non-thermal penetration of the epidermis followed by RF coagulation in selected depth of the dermis surrounded by zone of non-coagulative volumetric heating. The first generation of Microneedle RF applicators used insulated needles. These treatments were limited by a few factors, including low volume of dermal heating, lack of effect in the papillary dermis and pinpoint bleeding during the treatment. The system tested in this study (EndyMed PRO, Intensif applicator, EndyMed Medical, Cesarea, Israel) utilizes special extra sharp tapered non-insulated microneedles and a special pulse mode, allowing full coagulation during treatment and higher effective volume of dermal heat. After Ethics Committee approval, one female pig (Type Large white X Landrace, 34 Kg) was chosen for the study. The animal was anesthetized using Ketamine, Xylazin and Isofluran. The EndyMed PRO, Intensif applicator (was used for treatment with different needle depth penetration (1 mm-3.5 mm) and in multiple energy settings. Six mm punch biopsies were harvested for histological analysis at the following time points: immediately after the treatment, 4 days after the treatment and 14 days after the treatment. H&E and Masson-Trichrome stains were processed. Visual inspection of the treated skin, immediately after the treatment, revealed arrays of pinpoint erythematous papules surrounded by undamaged epidermal tissue. Treatment field showed no sign of bleeding. Mild to moderate Erythema and Edema developed a few minutes after the treatment, varying according to the total energy delivered. The histologies taken 4-day after therapy showed in all energy settings, dry micro crusts over the treatment zones, with full healing of epidermis. In the 14-day specimens there was a replacement of the crusts/debris by a normal looking stratum corneum with complete healing of epidermis and dermis. The current in vivo study confirms that the EndyMed PRO Intensif applicator effective and predictable tool to create cylindrical micro zones of coagulation in the papillary and reticular dermis with minimal damage to the epidermis. The histologies taken 4 days and 14 days after treatment show rapid epidermal renewal with predictable volume of coagulation in dermis related to the length of the needle and the power used. Coagulation of capillaries during treatment allows a dry treatment field. The predictability of the effect and minimal downtime may offer a significant advantage over treatments with ablative fractional lasers of insulated RF microneedles.
The effects of radio-frequency electromagnetic fields on T cell function during development
Ohtani, Shin; Ushiyama, Akira; Maeda, Machiko; Ogasawara, Yuki; Wang, Jianqing; Kunugita, Naoki; Ishii, Kazuyuki
2015-01-01
With the widespread use of radio-frequency devices, it is increasingly important to understand the biological effects of the associated electromagnetic fields. Thus, we investigated the effects of radio-frequency electromagnetic fields (RF-EMF) on T cell responses during development due to the lack of science-based evidence for RF-EMF effects on developmental immune systems. Sprague Dawley (SD) rats were exposed to 2.14-GHz wideband code division multiple-access (W-CDMA) RF signals at a whole-body specific absorption rate (SAR) of 0.2 W/kg. Exposures were performed for a total of 9 weeks spanning in utero development, lactation and the juvenile period. Rats were continuously exposed to RF-EMF for 20 h/day, 7 days/week. Comparisons of control and exposed rats using flow cytometry revealed no changes in the numbers of CD4/CD8 T cells, activated T cells or regulatory T cells among peripheral blood cells, splenocytes and thymocytes. Expression levels of 16 genes that regulate the immunological Th1/Th2 paradigm were analyzed using real-time PCR in the spleen and thymus tissues of control and RF-EMF–exposed rats. Although only the Il5 gene was significantly regulated in spleen tissues, Il4, Il5 and Il23a genes were significantly upregulated in thymus tissues following exposure to RF-EMF. However, ELISAs showed no changes in serum IL-4 protein concentrations. These data indicate no adverse effects of long-term RF-EMF exposure on immune-like T cell populations, T cell activation, or Th1/Th2 balance in developing rats, although significant transcriptional effects were observed. PMID:25835473
Developing field emission electron sources based on ultrananocrystalline diamond for accelerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baryshev, Sergey V.; Jing, Chunguang; Qiu, Jiaqi
Radiofrequency (RF) electron guns work by establishing an RF electromagnetic field inside a cavity having conducting walls. Electrons from a cathode are generated in the injector and immediately become accelerated by the RF electric field, and exit the gun as a series of electron bunches. Finding simple solutions for electron injection is a long standing problem. While energies of 30-50 MeV are achievable in linear accelerators (linacs), finding an electron source able to survive under MW electric loads and provide an average current of 1-10 mA is important. Meeting these requirements would open various linac applications for industry. The naturalmore » way to simplify and integrate RF injector architectures with the electron source would be to place the source directly into the RF cavity with no need for additional heaters/lasers. Euclid TechLabs in collaboration with Argonne National Lab are prototyping a family of highly effective field emission electron sources based on a nitrogen-incorporated ultrananocrystalline diamond ((N)UNCD) platform. Determined metrics suggest that our emitters are emissive enough to meet requirements for magnetized cooling at electron-ion colliders, linac-based radioisotope production and X-ray sterilization, and others.« less
Recent developments in trapping and manipulation of atoms with adiabatic potentials
NASA Astrophysics Data System (ADS)
Garraway, Barry M.; Perrin, Hélène
2016-09-01
A combination of static and oscillating magnetic fields can be used to ‘dress’ atoms with radio-frequency (RF), or microwave, radiation. The spatial variation of these fields can be used to create an enormous variety of traps for ultra-cold atoms and quantum gases. This article reviews the type and character of these adiabatic traps and the applications which include atom interferometry and the study of low-dimensional quantum systems. We introduce the main concepts of magnetic traps leading to adiabatic dressed traps. The concept of adiabaticity is discussed in the context of the Landau-Zener model. The first bubble trap experiment is reviewed together with the method used for loading it. Experiments based on atom chips show the production of double wells and ring traps. Dressed atom traps can be evaporatively cooled with an additional RF field, and a weak RF field can be used to probe the spectroscopy of the adiabatic potentials. Several approaches to ring traps formed from adiabatic potentials are discussed, including those based on atom chips, time-averaged adiabatic potentials and induction methods. Several proposals for adiabatic lattices with dressed atoms are also reviewed.
Radio frequency sheaths in an oblique magnetic field
Myra, James R.; D'Ippolito, Daniel A.
2015-06-01
The physics of radio-frequency (rf) sheaths near a conducting surface is studied for plasmas immersed in a magnetic field that makes an oblique angle θ with the surface. A set of one-dimensional equations is developed that describe the dynamics of the time-dependent magnetic presheath and non-neutral Debye sheath. The model employs Maxwell-Boltzmann electrons, and the magnetization and mobility of the ions is determined by the magnetic field strength, and wave frequency, respectively. The angle, θ assumed to be large enough to insure an electron-poor sheath, is otherwise arbitrary. Concentrating on the ion-cyclotron range of frequencies, the equations are solved numericallymore » to obtain the rectified (dc) voltage, the rf voltage across the sheath and the rf current flowing through the sheath. As an application of this model, the sheath voltage-current relation is used to obtain the rf sheath impedance, which in turn gives an rf sheath boundary condition for the electric field at the sheath-plasma interface that can be used in rf wave codes. In general the impedance has both resistive and capacitive contributions, and generalizes previous sheath boundary condition models. The resistive part contributes to parasitic power dissipation at the wall.« less
Quantum sensing of weak radio-frequency signals by pulsed Mollow absorption spectroscopy.
Joas, T; Waeber, A M; Braunbeck, G; Reinhard, F
2017-10-17
Quantum sensors-qubits sensitive to external fields-have become powerful detectors for various small acoustic and electromagnetic fields. A major key to their success have been dynamical decoupling protocols which enhance sensitivity to weak oscillating (AC) signals. Currently, those methods are limited to signal frequencies below a few MHz. Here we harness a quantum-optical effect, the Mollow triplet splitting of a strongly driven two-level system, to overcome this limitation. We microscopically understand this effect as a pulsed dynamical decoupling protocol and find that it enables sensitive detection of fields close to the driven transition. Employing a nitrogen-vacancy center, we detect GHz microwave fields with a signal strength (Rabi frequency) below the current detection limit, which is set by the center's spectral linewidth [Formula: see text]. Pushing detection sensitivity to the much lower 1/T 2 limit, this scheme could enable various applications, most prominently coherent coupling to single phonons and microwave photons.Dynamical decoupling protocols can enhance the sensitivity of quantum sensors but this is limited to signal frequencies below a few MHz. Here, Joas et al. use the Mollow triplet splitting in a nitrogen-vacancy centre to overcome this limitation, enabling sensitive detection of signals in the GHz range.
21 CFR 882.4725 - Radiofrequency lesion probe.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...
21 CFR 882.4725 - Radiofrequency lesion probe.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...
21 CFR 882.4725 - Radiofrequency lesion probe.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...
21 CFR 882.4725 - Radiofrequency lesion probe.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...
21 CFR 882.4725 - Radiofrequency lesion probe.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...
Conceptual design of a sapphire loaded coupler for superconducting radio-frequency 1.3 GHz cavities
Xu, Chen; Tantawi, Sami
2016-02-25
This paper explores a hybrid mode rf structure that served as a superconducting radio-frequency coupler. This application achieves a reflection S (1,1) varying from 0 to -30 db and delivers cw power at 7 KW. The coupler has good thermal isolation between the 2 and 300 K sections due to vacuum separation. Only one single hybrid mode can propagate through each section, and no higher order mode is coupled. The analytical and numerical analysis for this coupler is given and the design is optimized. As a result, the coupling mechanism to the cavity is also discussed.
Duncan, Diane Irvine; Kim, Theresa H. M.; Temaat, Robbin
2016-01-01
Noninvasive fat reduction is claimed by many device manufacturers, but proof of efficacy has been difficult to establish. This prospective study was designed to measure the reduction of fat thickness and actual volume reduction in 20 female patients treated with an external radiofrequency (RF) device. This device combines RF heat, suction coupled vacuum, and oscillating electrical pulses that induce adipocyte death over time. Patients underwent pre- and post-treatment and intercurrent measurements of weight, body mass index, ultrasonic transcutaneous fat thickness, and 2D and 3D Vectra photography with independent calculation of circumferential and volumetric change. Mean transcutaneous ultrasound thickness at reproducible points was 2.78 cm; at 1-month post-treatment, the mean fat thickness was 1.71 cm. At 3-month post-treatment, the mean fat thickness reduction was 39.6%. Vectra circumference measurements were taken at 10-mm intervals, with postural and breathing cycle control. Independent analysis of serial measurements from + 60 to − 70 mm showed mean abdominal circumference measurement of 2.3 cm. Mean abdominal volume loss was 202.4 and 428.5 cc at 1- and 3-month post-treatment, respectively. Scanning electron microscopy confirmed that permanent cell destruction was caused by irreversible electroporation. Pyroptosis appears to be the mechanism of action. PMID:26962636
A method for safety testing of radiofrequency/microwave-emitting devices using MRI.
Alon, Leeor; Cho, Gene Y; Yang, Xing; Sodickson, Daniel K; Deniz, Cem M
2015-11-01
Strict regulations are imposed on the amount of radiofrequency (RF) energy that devices can emit to prevent excessive deposition of RF energy into the body. In this study, we investigated the application of MR temperature mapping and 10-g average specific absorption rate (SAR) computation for safety evaluation of RF-emitting devices. Quantification of the RF power deposition was shown for an MRI-compatible dipole antenna and a non-MRI-compatible mobile phone via phantom temperature change measurements. Validation of the MR temperature mapping method was demonstrated by comparison with physical temperature measurements and electromagnetic field simulations. MR temperature measurements alongside physical property measurements were used to reconstruct 10-g average SAR. The maximum temperature change for a dipole antenna and the maximum 10-g average SAR were 1.83°C and 12.4 W/kg, respectively, for simulations and 1.73°C and 11.9 W/kg, respectively, for experiments. The difference between MR and probe thermometry was <0.15°C. The maximum temperature change and the maximum 10-g average SAR for a cell phone radiating at maximum output for 15 min was 1.7°C and 0.54 W/kg, respectively. Information acquired using MR temperature mapping and thermal property measurements can assess RF/microwave safety with high resolution and fidelity. © 2014 Wiley Periodicals, Inc.
Brown, Ryan; Deniz, Cem Murat; Zhang, Bei; Chang, Gregory; Sodickson, Daniel K.; Wiggins, Graham C.
2014-01-01
Objective The objective of the study was to investigate the feasibility of 7-T shoulder magnetic resonance imaging by developing transmit and receive radiofrequency (RF) coil arrays and exploring RF shim methods. Materials and Methods A mechanically flexible 8-channel transmit array and an anatomically conformable 10-channel receive array were designed and implemented. The transmit performance of various RF shim methods was assessed through local flip angle measurements in the right and left shoulders of 6 subjects. The receive performance was assessed through signal-to-noise ratio measurements using the developed 7-T coil and a baseline commercial 3-T coil. Results The 7-T transmit array driven with phase-coherent RF shim weights provided adequate B1+ efficiency and uniformity for turbo spin echo shoulder imaging. B1+ twisting that is characteristic of high-field loop coils necessitates distinct RF shim weights in the right and left shoulders. The 7-T receive array provided a 2-fold signal-to-noise ratio improvement over the 3-T array in the deep articular shoulder cartilage. Conclusions Shoulder imaging at 7-T is feasible with a custom transmit/receive array either in a single-channel transmit mode with a fixed RF shim or in a parallel transmit mode with a subject-specific RF shim. PMID:24056112
A Method for Safety Testing of Radiofrequency/Microwave-Emitting Devices Using MRI
Alon, Leeor; Cho, Gene Y.; Yang, Xing; Sodickson, Daniel K.; Deniz, Cem M.
2015-01-01
Purpose Strict regulations are imposed on the amount of radiofrequency (RF) energy that devices can emit to prevent excessive deposition of RF energy into the body. In this study, we investigated the application of MR temperature mapping and 10-g average specific absorption rate (SAR) computation for safety evaluation of RF-emitting devices. Methods Quantification of the RF power deposition was shown for an MRI-compatible dipole antenna and a non–MRI-compatible mobile phone via phantom temperature change measurements. Validation of the MR temperature mapping method was demonstrated by comparison with physical temperature measurements and electromagnetic field simulations. MR temperature measurements alongside physical property measurements were used to reconstruct 10-g average SAR. Results The maximum temperature change for a dipole antenna and the maximum 10-g average SAR were 1.83° C and 12.4 W/kg, respectively, for simulations and 1.73° C and 11.9 W/kg, respectively, for experiments. The difference between MR and probe thermometry was <0.15° C. The maximum temperature change and the maximum 10-g average SAR for a cell phone radiating at maximum output for 15 min was 1.7° C and 0.54 W/kg, respectively. Conclusion Information acquired using MR temperature mapping and thermal property measurements can assess RF/microwave safety with high resolution and fidelity. PMID:25424724
Ultralow-power organic complementary circuits.
Klauk, Hagen; Zschieschang, Ute; Pflaum, Jens; Halik, Marcus
2007-02-15
The prospect of using low-temperature processable organic semiconductors to implement transistors, circuits, displays and sensors on arbitrary substrates, such as glass or plastics, offers enormous potential for a wide range of electronic products. Of particular interest are portable devices that can be powered by small batteries or by near-field radio-frequency coupling. The main problem with existing approaches is the large power consumption of conventional organic circuits, which makes battery-powered applications problematic, if not impossible. Here we demonstrate an organic circuit with very low power consumption that uses a self-assembled monolayer gate dielectric and two different air-stable molecular semiconductors (pentacene and hexadecafluorocopperphthalocyanine, F16CuPc). The monolayer dielectric is grown on patterned metal gates at room temperature and is optimized to provide a large gate capacitance and low gate leakage currents. By combining low-voltage p-channel and n-channel organic thin-film transistors in a complementary circuit design, the static currents are reduced to below 100 pA per logic gate. We have fabricated complementary inverters, NAND gates, and ring oscillators that operate with supply voltages between 1.5 and 3 V and have a static power consumption of less than 1 nW per logic gate. These organic circuits are thus well suited for battery-powered systems such as portable display devices and large-surface sensor networks as well as for radio-frequency identification tags with extended operating range.
Duncan, Diane Irvine; Kim, Theresa H M; Temaat, Robbin
2016-10-01
Noninvasive fat reduction is claimed by many device manufacturers, but proof of efficacy has been difficult to establish. This prospective study was designed to measure the reduction of fat thickness and actual volume reduction in 20 female patients treated with an external radiofrequency (RF) device. This device combines RF heat, suction coupled vacuum, and oscillating electrical pulses that induce adipocyte death over time. Patients underwent pre- and post-treatment and intercurrent measurements of weight, body mass index, ultrasonic transcutaneous fat thickness, and 2D and 3D Vectra photography with independent calculation of circumferential and volumetric change. Mean transcutaneous ultrasound thickness at reproducible points was 2.78 cm; at 1-month post-treatment, the mean fat thickness was 1.71 cm. At 3-month post-treatment, the mean fat thickness reduction was 39.6%. Vectra circumference measurements were taken at 10-mm intervals, with postural and breathing cycle control. Independent analysis of serial measurements from + 60 to - 70 mm showed mean abdominal circumference measurement of 2.3 cm. Mean abdominal volume loss was 202.4 and 428.5 cc at 1- and 3-month post-treatment, respectively. Scanning electron microscopy confirmed that permanent cell destruction was caused by irreversible electroporation. Pyroptosis appears to be the mechanism of action.
Taheri, M; Mortazavi, S M J; Moradi, M; Mansouri, S; Hatam, G R; Nouri, F
2017-01-01
Mobile phones and Wi-Fi radiofrequency radiation are among the main sources of the exposure of the general population to radiofrequency electromagnetic fields (RF-EMF). Previous studies have shown that exposure of microorganisms to RF-EMFs can be associated with a wide spectrum of changes ranged from the modified bacterial growth to the alterations of the pattern of antibiotic resistance. Our laboratory at the nonionizing department of the Ionizing and Non-ionizing Radiation Protection Research Center has performed experiments on the health effects of exposure to animal models and humans to different sources of electromagnetic fields such as cellular phones, mobile base stations, mobile phone jammers, laptop computers, radars, dentistry cavitrons, magnetic resonance imaging, and Helmholtz coils. On the other hand, we have previously studied different aspects of the challenging issue of the ionizing or nonionizing radiation-induced alterations in the susceptibility of microorganisms to antibiotics. In this study, we assessed if the exposure to 900 MHz GSM mobile phone radiation and 2.4 GHz radiofrequency radiation emitted from common Wi-Fi routers alters the susceptibility of microorganisms to different antibiotics. The pure cultures of Listeria monocytogenes and Escherichia coli were exposed to RF-EMFs generated either by a GSM 900 MHz mobile phone simulator and a common 2.4 GHz Wi-Fi router. It is also shown that exposure to RF-EMFs within a narrow level of irradiation (an exposure window) makes microorganisms resistant to antibiotics. This adaptive phenomenon and its potential threats to human health should be further investigated in future experiments. Altogether, the findings of this study showed that exposure to Wi-Fi and RF simulator radiation can significantly alter the inhibition zone diameters and growth rate for L monocytogenes and E coli. These findings may have implications for the management of serious infectious diseases.
Taheri, M.; Mansouri, S.; Hatam, G. R.; Nouri, F.
2017-01-01
Mobile phones and Wi-Fi radiofrequency radiation are among the main sources of the exposure of the general population to radiofrequency electromagnetic fields (RF-EMF). Previous studies have shown that exposure of microorganisms to RF-EMFs can be associated with a wide spectrum of changes ranged from the modified bacterial growth to the alterations of the pattern of antibiotic resistance. Our laboratory at the nonionizing department of the Ionizing and Non-ionizing Radiation Protection Research Center has performed experiments on the health effects of exposure to animal models and humans to different sources of electromagnetic fields such as cellular phones, mobile base stations, mobile phone jammers, laptop computers, radars, dentistry cavitrons, magnetic resonance imaging, and Helmholtz coils. On the other hand, we have previously studied different aspects of the challenging issue of the ionizing or nonionizing radiation-induced alterations in the susceptibility of microorganisms to antibiotics. In this study, we assessed if the exposure to 900 MHz GSM mobile phone radiation and 2.4 GHz radiofrequency radiation emitted from common Wi-Fi routers alters the susceptibility of microorganisms to different antibiotics. The pure cultures of Listeria monocytogenes and Escherichia coli were exposed to RF-EMFs generated either by a GSM 900 MHz mobile phone simulator and a common 2.4 GHz Wi-Fi router. It is also shown that exposure to RF-EMFs within a narrow level of irradiation (an exposure window) makes microorganisms resistant to antibiotics. This adaptive phenomenon and its potential threats to human health should be further investigated in future experiments. Altogether, the findings of this study showed that exposure to Wi-Fi and RF simulator radiation can significantly alter the inhibition zone diameters and growth rate for L monocytogenes and E coli. These findings may have implications for the management of serious infectious diseases. PMID:28203122
Brzozek, Christopher; Benke, Kurt K; Zeleke, Berihun M; Abramson, Michael J; Benke, Geza
2018-03-26
Uncertainty in experimental studies of exposure to radiation from mobile phones has in the past only been framed within the context of statistical variability. It is now becoming more apparent to researchers that epistemic or reducible uncertainties can also affect the total error in results. These uncertainties are derived from a wide range of sources including human error, such as data transcription, model structure, measurement and linguistic errors in communication. The issue of epistemic uncertainty is reviewed and interpreted in the context of the MoRPhEUS, ExPOSURE and HERMES cohort studies which investigate the effect of radiofrequency electromagnetic radiation from mobile phones on memory performance. Research into this field has found inconsistent results due to limitations from a range of epistemic sources. Potential analytic approaches are suggested based on quantification of epistemic error using Monte Carlo simulation. It is recommended that future studies investigating the relationship between radiofrequency electromagnetic radiation and memory performance pay more attention to treatment of epistemic uncertainties as well as further research into improving exposure assessment. Use of directed acyclic graphs is also encouraged to display the assumed covariate relationship.
Ellenor, Christopher W; Stang, Pascal P; Etezadi-Amoli, Maryam; Pauly, John M; Scott, Greig C
2015-01-01
Purpose The concept of a “radiofrequency safety prescreen” is investigated, wherein dangerous interactions between radiofrequency fields used in MRI, and conductive implants in patients are detected through impedance changes in the radiofrequency coil. Theory The behavior of coupled oscillators is reviewed, and the resulting, observable impedance changes are discussed. Methods A birdcage coil is loaded with a static head phantom and a wire phantom with a wire close to its resonant length, the shape, position, and orientation of which can be changed. Interactions are probed with a current sensor and network analyzer. Results Impedance spectra show dramatic, unmistakable splitting in cases of strong coupling, and strong correlation is observed between induced current and scattering parameters. Conclusions The feasibility of a new, low-power prescreening technique has been demonstrated in a simple phantom experiment, which can unambiguously detect resonant interactions between an implanted wire and an imaging coil. A new technique has also been presented which can detect parallel transmit null modes for the wire. Magn Reson Med 73:1328–1339, 2015. © 2014 Wiley Periodicals, Inc. PMID:24623586
Goavec-Mérou, G; Chrétien, N; Friedt, J-M; Sandoz, P; Martin, G; Lenczner, M; Ballandras, S
2014-01-01
Vibrating mechanical structure characterization is demonstrated using contactless techniques best suited for mobile and rotating equipments. Fast measurement rates are achieved using Field Programmable Gate Array (FPGA) devices as real-time digital signal processors. Two kinds of algorithms are implemented on FPGA and experimentally validated in the case of the vibrating tuning fork. A first application concerns in-plane displacement detection by vision with sampling rates above 10 kHz, thus reaching frequency ranges above the audio range. A second demonstration concerns pulsed-RADAR cooperative target phase detection and is applied to radiofrequency acoustic transducers used as passive wireless strain gauges. In this case, the 250 ksamples/s refresh rate achieved is only limited by the acoustic sensor design but not by the detection bandwidth. These realizations illustrate the efficiency, interest, and potentialities of FPGA-based real-time digital signal processing for the contactless interrogation of passive embedded probes with high refresh rates.
Kiourti, Asimina; Psathas, Konstantinos A; Nikita, Konstantina S
2014-01-01
Wireless medical telemetry permits the measurement of physiological signals at a distance through wireless technologies. One of the latest applications is in the field of implantable and ingestible medical devices (IIMDs) with integrated antennas for wireless radiofrequency (RF) communication (telemetry) with exterior monitoring/control equipment. Implantable medical devices (MDs) perform an expanding variety of diagnostic and therapeutic functions, while ingestible MDs receive significant attention in gastrointestinal endoscopy. Design of such wireless IIMD telemetry systems is highly intriguing and deals with issues related to: operation frequency selection, electronics and powering, antenna design and performance, and modeling of the wireless channel. In this paper, we attempt to comparatively review the current status and challenges of IIMDs with wireless telemetry functionalities. Full solutions of commercial IIMDs are also recorded. The objective is to provide a comprehensive reference for scientists and developers in the field, while indicating directions for future research. © 2013 Wiley Periodicals, Inc.
Effects of pulsed electromagnetic fields on benign prostate hyperplasia.
Giannakopoulos, Xenophon K; Giotis, Christos; Karkabounas, Spyridon Ch; Verginadis, Ioannis I; Simos, Yannis V; Peschos, Dimitrios; Evangelou, Angelos M
2011-12-01
Benign prostate hyperplasia (BPH) has been treated with various types of electromagnetic radiation methods such as transurethral needle ablation (TUNA), interstitial laser therapy (ILC), holmium laser resection (HoLRP). In the present study, the effects of a noninvasive method based on the exposure of patients with BPH to a pulsative EM Field at radiofrequencies have been investigated. Twenty patients with BPH, aging 68-78 years old (y.o), were enrolled in the study. Patients were randomly divided into two groups: the treatment group (10 patients, 74.0 ± 5.7 y.o) treated with the α-blocker Alfusosin, 10 mg/24 h for at least 4 weeks, and the electromagnetic group (10 patients, 73.7 ± 6.3 y.o) exposed for 2 weeks in a very short wave duration, pulsed electromagnetic field at radiofrequencies generated by an ion magnetic inductor, for 30 min daily, 5 consecutive days per week. Patients of both groups were evaluated before and after drug and EMF treatment by values of total PSA and prostatic PSA fraction, acid phosphate, U/S estimation of prostate volume and urine residue, urodynamic estimation of urine flow rate, and International Prostate Symptom Score (IPSS). There was a statistically significant decrease before and after treatment of IPSS (P < 0.02), U/S prostate volume (P < 0.05), and urine residue (P < 0.05), as well as of mean urine flow rate (P < 0.05) in patients of the electromagnetic group, in contrast to the treatment group who had only improved IPSS (P < 0.05). There was also a significant improvement in clinical symptoms in patients of the electromagnetic group. Follow-up of the patients of this group for one year revealed that results obtained by EMFs treatment are still remaining. Pulsed electromagnetic field at radiofrequencies may benefit patients with benign prostate hyperplasia treated by a non-invasive method.
The radiofrequency magnetic dipole discharge
NASA Astrophysics Data System (ADS)
Martines, E.; Zuin, M.; Marcante, M.; Cavazzana, R.; Fassina, A.; Spolaore, M.
2016-05-01
This paper describes a novel and simple concept of plasma source, which is able to produce a radiofrequency magnetized discharge with minimal power requirements. The source is based on the magnetron concept and uses a permanent magnet as an active electrode. The dipolar field produced by the magnet confines the electrons, which cause further ionization, thus producing a toroidally shaped plasma in the equatorial region around the electrode. A plasma can be ignited with such scheme with power levels as low as 5 W. Paschen curves have been built for four different working gases, showing that in Helium or Neon, plasma breakdown is easily obtained also at atmospheric pressure. The plasma properties have been measured using a balanced Langmuir probe, showing that the electron temperature is around 3-4 eV and higher in the cathode proximity. Plasma densities of the order of 1016 m-3 have been obtained, with a good positive scaling with applied power. Overall, the electron pressure appears to be strongly correlated with the magnetic field magnitude in the measurement point.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gahan, D.; Hopkins, M. B.; Dolinaj, B.
2008-03-15
A retarding field energy analyzer designed to measure ion energy distributions impacting a radio-frequency biased electrode in a plasma discharge is examined. The analyzer is compact so that the need for differential pumping is avoided. The analyzer is designed to sit on the electrode surface, in place of the substrate, and the signal cables are fed out through the reactor side port. This prevents the need for modifications to the rf electrode--as is normally the case for analyzers built into such electrodes. The capabilities of the analyzer are demonstrated through experiments with various electrode bias conditions in an inductively coupledmore » plasma reactor. The electrode is initially grounded and the measured distributions are validated with the Langmuir probe measurements of the plasma potential. Ion energy distributions are then given for various rf bias voltage levels, discharge pressures, rf bias frequencies - 500 kHz to 30 MHz, and rf bias waveforms - sinusoidal, square, and dual frequency.« less
Dhungel, Amit; Zmirou-Navier, Denis; van Deventer, Emilie
2015-04-01
This study aims to describe current risk management practices and policies across the world in relation to personal exposures from devices emitting radiofrequency fields, environmental exposures from fixed installations and exposures in the work environment. Data from 86 countries representing all WHO regions were collected through a survey. The majority of countries (76.8 %) had set exposure limits for mobile devices, almost all (90.7 %) had set public exposure limits for fixed installations and 76.5 % had specified exposure limits for personnel in occupational settings. A number of other policies had been implemented at the national level, ranging from information provisions on how to reduce personal exposures and restrictions of usage for certain populations, such as children or pregnant women to prevention of access around base stations. This study suggests that countries with higher mobile subscriptions tend to have set radiofrequency exposure limits for mobile devices and to have provisions on exposure measurements about fixed installations. © The Author 2014. Published by Oxford University Press.
Special types of FBG and CoaxBG structures for telecommunication and monitoring systems
NASA Astrophysics Data System (ADS)
Morozov, Oleg G.; Nasybullin, Aidar R.; Morozov, Gennady A.; Danilaev, Maxim P.; Zastela, Mikhail Y.; Farkhutdinov, Rafael V.; Faskhutdinov, Lenar M.
2015-03-01
The technology of fiber Bragg gratings is used as one of the most applicable technologies for construction of fiber optic sensors and telecommunication systems. Periodic irregular wave resistance located in the guiding waveguide can be regarded as analog of the fiber Bragg grating structure in the field of radio-frequency. Coaxial waveguide can be used as a guide system, so a special case of this structure is the Bragg grating on coaxial cable. Recently, the special structure of sensors were beginning to be used with heterogeneity as a discrete phase π-shift. Based on the properties analysis of the Bragg reflection characteristics of structures with a phase shift in the optical and microwave range shown advantage of using these devices in measuring systems.
Mode Matching for Optical Antennas
NASA Astrophysics Data System (ADS)
Feichtner, Thorsten; Christiansen, Silke; Hecht, Bert
2017-11-01
The emission rate of a point dipole can be strongly increased in the presence of a well-designed optical antenna. Yet, optical antenna design is largely based on radio-frequency rules, ignoring, e.g., Ohmic losses and non-negligible field penetration in metals at optical frequencies. Here, we combine reciprocity and Poynting's theorem to derive a set of optical-frequency antenna design rules for benchmarking and optimizing the performance of optical antennas driven by single quantum emitters. Based on these findings a novel plasmonic cavity antenna design is presented exhibiting a considerably improved performance compared to a reference two-wire antenna. Our work will be useful for the design of high-performance optical antennas and nanoresonators for diverse applications ranging from quantum optics to antenna-enhanced single-emitter spectroscopy and sensing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halavanau, Aliaksei; Eddy, Nathan; Edstrom, Dean
Superconducting linacs are capable of producing intense, ultra-stable, high-quality electron beams that have widespread application in Science and Industry. Many current and planned projects employ 1.3-GHz 9-cell superconducting cavities of the TESLA design*. In the present paper we discuss the transverse-focusing properties of such a cavity and non-ideal transverse-map effects introduced by field asymmetries in the vicinity of the input and high-order-mode radiofrequency (RF) couplers**. We especially consider the case of a cavity located downstream of an RF-gun in a setup similar to the photoinjector of the Fermilab Accelerator Science and Technology (FAST) facility. Preliminary experimental measurements of the CC2more » cavity transverse matrix were carried out at the FAST facility. The results are discussed and compared with analytical and numerical simulations.« less
NASA Astrophysics Data System (ADS)
Wharmby, Andrew William
Existing fractional calculus models having a non-empirical basis used to describe constitutive relationships between stress and strain in viscoelastic materials are modified to employ all orders of fractional derivatives between zero and one. Parallels between viscoelastic and dielectric theory are drawn so that these modified fractional calculus based models for viscoelastic materials may be used to describe relationships between electric flux density and electric field intensity in dielectric materials. The resulting fractional calculus based dielectric relaxation model is tested using existing complex permittivity data in the radio-frequency bandwidth of a wide variety of homogeneous materials. The consequences that the application of this newly developed fractional calculus based dielectric relaxation model has on Maxwell's equations are also examined through the effects of dielectric dissipation and dispersion.
Basic Principles of Magnetic Resonance Imaging—An Update
Scherzinger, Ann L.; Hendee, William R.
1985-01-01
Magnetic resonance (MR) imaging technology has undergone many technologic advances over the past few years. Many of these advances were stimulated by the wealth of information emerging from nuclear magnetic resonance research in the areas of new and optimal scanning methods and radio-frequency coil design. Other changes arose from the desire to improve image quality, ease siting restrictions and generally facilitate the clinical use of MR equipment. Many questions, however, remain unanswered. Perhaps the most controversial technologic question involves the optimal field strength required for imaging or spectroscopic applications or both. Other issues include safety and clinical efficacy. Technologic issues affect all aspects of MR use including the choice of equipment, examination procedure and image interpretation. Thus, an understanding of recent changes and their theoretic basis is necessary. ImagesFigure 9. PMID:3911591
47 CFR 2.801 - Radiofrequency device defined.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency device defined. 2.801 Section 2... MATTERS; GENERAL RULES AND REGULATIONS Marketing of Radio-frequency Devices § 2.801 Radiofrequency device defined. As used in this part, a radiofrequency device is any device which in its operation is capable of...
Pulse-dose radiofrequency treatment in pain management-initial experience.
Ojango, Christine; Raguso, Mario; Fiori, Roberto; Masala, Salvatore
2018-05-01
Radiofrequency procedures have been used for treating various chronic pain conditions for decades. These minimally invasive percutaneous treatments employ an alternating electrical current with oscillating radiofrequency wavelengths to eliminate or alter pain signals from the targeted site. The aim of the continuous radiofrequency procedure is to increase the temperature sufficiently to create an irreversible thermal lesion on nerve fibres and thus permanently interrupt pain signals. The pulsed radiofrequency procedure utilises short pulses of radiofrequency current with intervals of longer pauses to avert a temperature increase to the level of permanent tissue damage. The goal of these pulses is to alter the processing of pain signals, but to avoid relevant structural damage to nerve fibres, as seen in the continuous radiofrequency procedure. The pulse-dose radiofrequency procedure is a technical improvement of the pulsed radiofrequency technique in which the delivery mode of the current is adapted. During the pulse-dose radiofrequency procedure thermal damage is avoided. In addition, the amplitude and width of the consecutive pulses are kept the same. The method ensures that each delivered pulse keeps the same characteristics and therefore the dose is similar between patients. The current review outlines the pulse-dose radiofrequency procedure and presents our institution's chronic pain management studies.
2005-07-06
C95.1-1991, American National Standard Safety Levels With Respect to Human Exposure to Radiofrequency Electromagnetic Fields , 300 kHz to 100 GHz. New...Site 4) were evaluated for possible siting of the ASR- 11. All three sites are situated in undeveloped fields on base. Site 2 is located between the...alternative ASR-1 1 sites. 3.12 ELECTROMAGNETIC ENERGY 3.12.1 Existing Conditions Electrical currents and components generate electrical fields and
Barellini, A; Bogi, L; Licitra, G; Silvi, A M; Zari, A
2009-12-01
Air traffic control (ATC) primary radars are 'classical' radars that use echoes of radiofrequency (RF) pulses from aircraft to determine their position. High-power RF pulses radiated from radar antennas may produce high electromagnetic field levels in the surrounding area. Measurement of electromagnetic fields produced by RF-pulsed radar by means of a swept-tuned spectrum analyser are investigated here. Measurements have been carried out both in the laboratory and in situ on signals generated by an ATC primary radar.
Reducing Field Distortion in Magnetic Resonance Imaging
NASA Technical Reports Server (NTRS)
Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob
2010-01-01
A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T
Mananga, Eugene S; Reid, Alicia E; Charpentier, Thibault
2012-02-01
This article describes the use of an alternative expansion scheme called Floquet-Magnus expansion (FME) to study the dynamics of spin system in solid-state NMR. The main tool used to describe the effect of time-dependent interactions in NMR is the average Hamiltonian theory (AHT). However, some NMR experiments, such as sample rotation and pulse crafting, seem to be more conveniently described using the Floquet theory (FT). Here, we present the first report highlighting the basics of the Floquet-Magnus expansion (FME) scheme and hint at its application on recoupling sequences that excite more efficiently double-quantum coherences, namely BABA and C7 radiofrequency pulse sequences. The use of Λ(n)(t) functions available only in the FME scheme, allows the comparison of the efficiency of BABA and C7 sequences. Copyright © 2011 Elsevier Inc. All rights reserved.
Reid, Alicia E.; Charpentier, Thibault
2013-01-01
This article describes the use of an alternative expansion scheme called Floquet-Magnus expansion (FME) to study the dynamics of spin system in solid-state NMR. The main tool used to describe the effect of time-dependent interactions in NMR is the average Hamiltonian theory (AHT). However, some NMR experiments, such as sample rotation and pulse crafting, seem to be more conveniently described using the Floquet theory (FT). Here, we present the first report highlighting the basics of the Floquet-Magnus expansion (FME) scheme and hint at its application on recoupling sequences that excite more efficiently double-quantum coherences, namely BABA and C7 radiofrequency pulse sequences. The use of Λn(t) functions available only in the FME scheme, allows the comparison of the efficiency of BABA and C7 sequences. PMID:22197191
2011-04-01
Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields ’, OET Bulletin 65, August 1997. 2. DA Pamphlet...wide range of frequencies, there is no single value for the Maximum Permissible Exposure (MPE). As recommended, the FCC MPE, reference 1, to...power accumulated in a 6-min period. The FCC defines general population/uncontrolled exposures as situations in which the general public may be
Court-Kowalski, Stefan; Finnie, John W; Manavis, Jim; Blumbergs, Peter C; Helps, Stephen C; Vink, Robert
2015-04-01
This study was designed to determine whether long-term (2 years) brain exposure to mobile telephone radiofrequency (RF) fields produces any astrocytic activation as these glia react to a wide range of neural perturbations by astrogliosis. Using a purpose-designed exposure system at 900 MHz, mice were given a single, far-field whole body exposure at a specific absorption rate of 4 W/kg on five successive days per week for 104 weeks. Control mice were sham-exposed or freely mobile in a cage to control any stress caused by immobilization in the exposure module. Brains were perfusion-fixed with 4% paraformaldehyde and three coronal levels immunostained for glial fibrillary acidic protein (GFAP). These brain slices were then examined by light microscopy and the amount of this immunomarker quantified using a color deconvolution method. There was no change in astrocytic GFAP immunostaining in brains after long-term exposure to mobile telephony microwaves compared to control (sham-exposed or freely moving caged mice). It was concluded that long-term (2 years) exposure of murine brains to mobile telephone RF fields did not produce any astrocytic reaction (astrogliosis) detectable by GFAP immunostaining. © 2015 Wiley Periodicals, Inc.
Sakakura, Kenichi; Ladich, Elena; Fuimaono, Kristine; Grunewald, Debby; O'Fallon, Patrick; Spognardi, Anna-Maria; Markham, Peter; Otsuka, Fumiyuki; Yahagi, Kazuyuki; Shen, Kai; Kolodgie, Frank D; Joner, Michael; Virmani, Renu
2015-01-01
The long-term efficacy of radiofrequency ablation of renal autonomic nerves has been proven in nonrandomized studies. However, long-term safety of the renal artery (RA) is of concern. The aim of our study was to determine if cooling during radiofrequency ablation preserved the RA while allowing equivalent nerve damage. A total of 9 swine (18 RAs) were included, and allocated to irrigated radiofrequency (n=6 RAs, temperature setting: 50°C), conventional radiofrequency (n=6 RAs, nonirrigated, temperature setting: 65°C), and high-temperature radiofrequency (n=6 RAs, nonirrigated, temperature setting: 90°C) groups. RAs were harvested at 10 days, serially sectioned from proximal to distal including perirenal tissues and examined after paraffin embedding, and staining with hematoxylin-eosin and Movat pentachrome. RAs and periarterial tissue including nerves were semiquantitatively assessed and scored. A total of 660 histological sections from 18 RAs were histologically examined by light microscopy. Arterial medial injury was significantly less in the irrigated radiofrequency group (depth of medial injury, circumferential involvement, and thinning) than that in the conventional radiofrequency group (P<0.001 for circumference; P=0.003 for thinning). Severe collagen damage such as denatured collagen was also significantly less in the irrigated compared with the conventional radiofrequency group (P<0.001). Nerve damage although not statistically different between the irrigated radiofrequency group and conventional radiofrequency group (P=0.36), there was a trend toward less nerve damage in the irrigated compared with conventional. Compared to conventional radiofrequency, circumferential medial damage in highest-temperature nonirrigated radiofrequency group was significantly greater (P<0.001). Saline irrigation significantly reduces arterial and periarterial tissue damage during radiofrequency ablation, and there is a trend toward less nerve damage. © 2014 American Heart Association, Inc.
Mortazavi, S M J; Rahimi, S; Talebi, A; Soleimani, A; Rafati, A
2015-09-01
The rapid development of wireless telecommunication technologies over the past decades, has led to significant changes in the exposure of the general public to electromagnetic fields. Nowadays, people are continuously exposed to different sources of electromagnetic fields such as mobile phones, mobile base stations, cordless phones, Wi-Fi routers, and power lines. Therefore, the last decade witnessed a rapidly growing concern about the possible health effects of exposure to electromagnetic fields emitted by these sources. In this study that was aimed at investigating the effects of exposure to radiofrequency (RF) radiation emitted by a GSM mobile phone on the pattern of contraction in frog's isolated gastrocnemius muscle after stimulation with single square pulses of 1V (1 Hz), pulse height of contractions, the time interval between two subsequent contractions and the latency period were measured. Our findings showed that the pulse height of contractions muscle could be affected by the exposure to electromagnetic fields. Especially, the latency period was effectively altered in RF-exposed samples. However, none of the experiments could show an alteration in the time interval between two subsequent contractions after exposure to electromagnetic fields. These findings support early reports which indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians including the effects on the pattern of muscle extractions.
Lapin, Norman A; Krzykawska-Serda, Martyna; Ware, Matthew J; Curley, Steven A; Corr, Stuart J
Poor biodistribution and accumulation of chemotherapeutics in tumors due to limitations on diffusive transport and high intra-tumoral pressures (Jain RK, Nat Med. 7(9):987-989, 2001) have prompted the investigation of adjunctive therapies to improve treatment outcomes. Hyperthermia has been widely applied in attempts to meet this need, but it is limited in its ability to reach tumors in deeply located body regions. High-intensity radiofrequency (RF) electric fields have the potential to overcome such barriers enhancing delivery and extravasation of chemotherapeutics. However, due to factors, including tumor heterogeneity and lack of kinetic information, there is insufficient understanding of time-resolved interaction between RF fields and tumor vasculature, drug molecules and nanoparticle (NP) vectors. Intravital microscopy (IVM) provides time-resolved high-definition images of specific tumor microenvironments, overcoming heterogeneity issues, and can be integrated with a portable RF device to enable detailed observation over time of the effects of the RF field on kinetics and biodistribution at the microvascular level. Herein, we provide a protocol describing the safe integration of IVM with a high-powered non-invasive RF field applied to 4T1 orthotopic breast tumors in live mice. Results show increased perfusion of NPs in microvasculature upon RF hyperthermia treatment and increased perfusion, release and spreading of injected reagents preferentially in irregular vessels during RF exposure.
[Patient exposure to electromagnetic fields in magnetic resonance scanners: a review].
Guibelalde del Castillo, E
2013-12-01
The use of non-ionizing electromagnetic fields in the low frequency end of the electromagnetic spectrum and static fields, radiofrequencies (RF), and microwaves is fundamental both in modern communication systems and in diagnostic medical imaging techniques like magnetic resonance imaging (MRI). The proliferation of these applications in recent decades has led to intense activity in developing regulations to guarantee their safety and to the establishment of guidelines and legal recommendations for the public, workers, and patients. In April 2012 it was foreseen that the European Parliament and Council would approve and publish a directive on the minimum health and safety requirements regarding the exposure of workers to the risks arising from electromagnetic fields, which would modify Directive 2004/40/EC. New studies related to the exposure to electromagnetic radiation and its impact on health published in recent years have led to a new postponement, and it is now foreseen that the directive will come into effect in October 2013. One of the most noteworthy aspects of the new version of the directive is the exclusion of the limits of occupational exposure to electromagnetic fields in the clinical use of MRI. In exchange for this exception, physicians and experts in protection against non-ionizing radiation are asked to make additional efforts to train workers exposed to non-ionizing radiation and to establish mechanisms to guarantee the correct application of non-ionizing electromagnetic fields in patients, along similar lines to the principles of justification and optimization established for ionizing radiation. On the basis of the most recently published studies, this article reviews some safety-related aspects to take into account when examining patients with MRI with high magnetic fields. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doleans, Marc
In this study, an in-situ plasma processing technique has been developed at the Spallation Neutron Source (SNS) to improve the performance of the superconducting radio-frequency (SRF) cavities in operation. The technique uses a low-density reactive neon-oxygen plasma at room-temperature to improve the surface work function, to help remove adsorbed gases on the RF surface and to reduce its secondary emission yield. SNS SRF cavities are six-cell elliptical cavities and the plasma typically ignites in the cell where the electric field is the highest. This article will detail a technique that was developed to ignite and monitor the plasma in eachmore » cell of the SNS cavities.« less
Doleans, Marc
2016-12-27
In this study, an in-situ plasma processing technique has been developed at the Spallation Neutron Source (SNS) to improve the performance of the superconducting radio-frequency (SRF) cavities in operation. The technique uses a low-density reactive neon-oxygen plasma at room-temperature to improve the surface work function, to help remove adsorbed gases on the RF surface and to reduce its secondary emission yield. SNS SRF cavities are six-cell elliptical cavities and the plasma typically ignites in the cell where the electric field is the highest. This article will detail a technique that was developed to ignite and monitor the plasma in eachmore » cell of the SNS cavities.« less
Thapa, Deepak; Ahuja, Vanita; Dass, Christopher; Verma, Parul
2015-01-01
Trigeminal neuralgia (TN) produces incapacitating facial pain that reduces quality of life in patients. Thermal radiofrequency (RF) ablation of gasserian ganglion (GG) is associated with masseter weakness and unpleasant sensations along the distribution of the ablated nerve. Pulsed radiofrequency (PRF) of GG has minimal side effects but literature is inconclusive regarding its benefit in refractory TN. Increasing the duration of PRF application to 6 minutes in TN produced encouraging results. PRF application to the saphenous nerve for 8 minutes reported improved pain relief and patient satisfaction. We report successful management of two patients of classic TN, which were refractory to medical management and interventional nerve blocks. The lesion site were confirmed with motor and sensory stimulation through a 22 G, 10 cm RF needle with 5 mm active tip. Both the patients received four cycles of PRF at 42 °C with each cycle of 120 seconds (8 minutes). The visual analogue scale (VAS) in case 1 reduced from pre-block score of 80 to score 10 post-block, while in case 2 the VAS reduced from pre-block score of 85 to score 15 post-block. During follow up both the patients are now pain free with minimal dose of carbamazepine at 12 and 6 months respectively. We used PRF for longer duration (8 minutes) in these patients, which resulted in improved VAS and WHOQOL-BREF score in these patients. PRF of mandibular division of GG for extended duration provided long-term effective pain relief and quality of life in patients of refractory classic TN.
Self-starting harmonic frequency comb generation in a quantum cascade laser
NASA Astrophysics Data System (ADS)
Kazakov, Dmitry; Piccardo, Marco; Wang, Yongrui; Chevalier, Paul; Mansuripur, Tobias S.; Xie, Feng; Zah, Chung-en; Lascola, Kevin; Belyanin, Alexey; Capasso, Federico
2017-12-01
Optical frequency combs1,2 establish a rigid phase-coherent link between microwave and optical domains and are emerging as high-precision tools in an increasing number of applications3. Frequency combs with large intermodal spacing are employed in the field of microwave photonics for radiofrequency arbitrary waveform synthesis4,5 and for the generation of terahertz tones of high spectral purity in future wireless communication networks6,7. Here, we demonstrate self-starting harmonic frequency comb generation with a terahertz repetition rate in a quantum cascade laser. The large intermodal spacing caused by the suppression of tens of adjacent cavity modes originates from a parametric contribution to the gain due to temporal modulations of population inversion in the laser8,9. Using multiheterodyne self-detection, the mode spacing of the harmonic comb is shown to be uniform to within 5 × 10-12 parts of the central frequency. This new harmonic comb state extends the range of applications of quantum cascade laser frequency combs10-13.
2012-02-07
circuits on mechanically flexible substrates for digital, analog and radio frequency applications. The asobtained thin-film transistors ( TFTs ) exhibit... flexible substrates for digital, analog and radio frequency applications. The as- obtained thin-film transistors ( TFTs ) exhibit highly uniform device...LCD) and organic light- emitting diode ( OLED ) displays lack the transparency and flexibility and are thus unsuitable for flexible electronic
Zhang, Xiaotong; Schmitter, Sebastian; Van de Moortel, Pierre-François; Liu, Jiaen
2014-01-01
Elevated Specific Absorption Rate (SAR) associated with increased main magnetic field strength remains as a major safety concern in ultra-high-field (UHF) Magnetic Resonance Imaging (MRI) applications. The calculation of local SAR requires the knowledge of the electric field induced by radiofrequency (RF) excitation, and the local electrical properties of tissues. Since electric field distribution cannot be directly mapped in conventional MR measurements, SAR estimation is usually performed using numerical model-based electromagnetic simulations which, however, are highly time consuming and cannot account for the specific anatomy and tissue properties of the subject undergoing a scan. In the present study, starting from the measurable RF magnetic fields (B1) in MRI, we conducted a series of mathematical deduction to estimate the local, voxel-wise and subject-specific SAR for each single coil element using a multi-channel transceiver array coil. We first evaluated the feasibility of this approach in numerical simulations including two different human head models. We further conducted experimental study in a physical phantom and in two human subjects at 7T using a multi-channel transceiver head coil. Accuracy of the results is discussed in the context of predicting local SAR in the human brain at UHF MRI using multi-channel RF transmission. PMID:23508259
Transient effects in π-pulse sequences in MAS solid-state NMR
NASA Astrophysics Data System (ADS)
Hellwagner, Johannes; Wili, Nino; Ibáñez, Luis Fábregas; Wittmann, Johannes J.; Meier, Beat H.; Ernst, Matthias
2018-02-01
Dipolar recoupling techniques that use isolated rotor-synchronized π pulses are commonly used in solid-state NMR spectroscopy to gain insight into the structure of biological molecules. These sequences excel through their simplicity, stability towards radio-frequency (rf) inhomogeneity, and low rf requirements. For a theoretical understanding of such sequences, we present a Floquet treatment based on an interaction-frame transformation including the chemical-shift offset dependence. This approach is applied to the homonuclear dipolar-recoupling sequence Radio-Frequency Driven Recoupling (RFDR) and the heteronuclear recoupling sequence Rotational Echo Double Resonance (REDOR). Based on the Floquet approach, we show the influence of effective fields caused by pulse transients and discuss the advantages of pulse-transient compensation. We demonstrate experimentally that the transfer efficiency for homonuclear recoupling can be doubled in some cases in model compounds as well as in simple peptides if pulse-transient compensation is applied to the π pulses. Additionally, we discuss the influence of various phase cycles on the recoupling efficiency in order to reduce the magnitude of effective fields. Based on the findings from RFDR, we are able to explain why the REDOR sequence does not suffer in the recoupling efficiency despite the presence of effective fields.
Radiofrequency exposure in the Neonatal Medium Care Unit.
Calvente, I; Vázquez-Pérez, A; Fernández, M F; Núñez, M I; Múñoz-Hoyos, A
2017-01-01
The aims of this study were to characterize electromagnetic fields of radiofrequency (RF-EMF) levels generated in a Neonatal Medium Care Unit and to analyze RF-EMF levels inside unit's incubators. Spot and long-term measurements were made with a dosimeter. The spot measurement mean was 1.51±0.48V/m. Higher values were found in the proximity to the window and to the incubator evaluated. Mean field strength for the entire period of 17h was 0.81 (±0.07)V/m and the maximum value was 1.58V/m for long-term RF-EMF measurements in the incubator. Values found during the night period were higher than those found during the day period. It is important to consider RF-EMF exposure levels in neonatal care units, due to some evidence of adverse health effects found in children and adults. Characterization of RF-EMF exposure may be important to further investigate the mechanisms and underlying effects of electromagnetic fields (EMF) on infant health. A prudent avoidance strategy should be adopted because newborns are at a vulnerable stage of development and the actual impact of EMF on premature infants is unknown. Copyright © 2016 Elsevier Inc. All rights reserved.
Piesnack, Susann; Frame, Mairi E; Oechtering, Gerhard; Ludewig, Eberhard
2013-01-01
The ability to read patient identification microchips relies on the use of radiofrequency pulses. Since radiofrequency pulses also form an integral part of the magnetic resonance imaging (MRI) process, the possibility of loss of microchip function during MRI scanning is of concern. Previous clinical trials have shown microchip function to be unaffected by MR imaging using a field strength of 1 Tesla and 1.5. As veterinary MRI scanners range widely in field strength, this study was devised to determine whether exposure to lower or higher field strengths than 1 Tesla would affect the function of different types of microchip. In a phantom study, a total of 300 International Standards Organisation (ISO)-approved microchips (100 each of three different types: ISO FDX-B 1.4 × 9 mm, ISO FDX-B 2.12 × 12 mm, ISO HDX 3.8 × 23 mm) were tested in a low field (0.5) and a high field scanner (3.0 Tesla). A total of 50 microchips of each type were tested in each scanner. The phantom was composed of a fluid-filled freezer pack onto which a plastic pillow and a cardboard strip with affixed microchips were positioned. Following an MRI scan protocol simulating a head study, all of the microchips were accurately readable. Neither 0.5 nor 3 Tesla imaging affected microchip function in this study. © 2013 Veterinary Radiology & Ultrasound.
Radiofrequency fields in MAS solid state NMR probes
NASA Astrophysics Data System (ADS)
Tošner, Zdeněk; Purea, Armin; Struppe, Jochem O.; Wegner, Sebastian; Engelke, Frank; Glaser, Steffen J.; Reif, Bernd
2017-11-01
We present a detailed analysis of the radiofrequency (RF) field over full volume of a rotor that is generated in a solenoid coil. On top of the usually considered static distribution of amplitudes along the coil axis we describe dynamic radial RF inhomogeneities induced by sample rotation. During magic angle spinning (MAS), the mechanical rotation of the sample about the magic angle, a spin packet travels through areas of different RF fields and experiences periodical modulations of both the RF amplitude and the phase. These modulations become particularly severe at the end regions of the coil where the relative RF amplitude varies up to ±25% and the RF phase changes within ±30°. Using extensive numerical simulations we demonstrate effects of RF inhomogeneity on pulse calibration and for the ramped CP experiment performed at a wide range of MAS rates. In addition, we review various methods to map RF fields using a B0 gradient along the sample (rotor axis) for imaging purposes. Under such a gradient, a nutation experiment provides directly the RF amplitude distribution, a cross polarization experiment images the correlation of the RF fields on the two channels according to the Hartmann-Hahn matching condition, while a spin-lock experiment allows to calibrate the RF amplitude employing the rotary resonance recoupling condition. Knowledge of the RF field distribution in a coil provides key to understand its effects on performance of a pulse sequence at the spectrometer and enables to set robustness requirements in the experimental design.
Arsanious, David; Gage, Emmanuel; Koning, Jonathon; Sarhan, Mazin; Chaiban, Gassan; Almualim, Mohammed; Atallah, Joseph
2016-01-01
One of the potential side effects with radiofrequency ablation (RFA) includes painful cutaneous dysesthesias and increased pain due to neuritis or neurogenic inflammation. This pain may require the prescription of opioids or non-opioid analgesics to control post-procedural pain and discomfort. The goal of this study is to compare post-procedural pain scores and post-procedural oral analgesic use in patients receiving continuous thermal radiofrequency ablation versus patients receiving pulsed dose radiofrequency immediately followed by continuous thermal radiofrequency ablation for zygopophaseal joint disease. This is a prospective, double-blinded, randomized, controlled trial. Patients who met all the inclusion criteria and were not subject to any of the exclusion criteria were required to have two positive diagnostic medial branch blocks prior to undergoing randomization, intervention, and analysis. University hospital. Eligible patients were randomized in a 1:1 ratio to either receive thermal radiofrequency ablation alone (standard group) or pulsed dose radiofrequency (PDRF) immediately followed by thermal radiofrequency ablation (investigational group), all of which were performed by a single Board Certified Pain Medicine physician. Post-procedural pain levels between the two groups were assessed using the numerical pain Scale (NPS), and patients were contacted by phone on post-procedural days 1 and 2 in the morning and afternoon regarding the amount of oral analgesic medications used in the first 48 hours following the procedure. Patients who received pulsed dose radiofrequency followed by continuous radiofrequency neurotomy reported statistically significantly lower post-procedural pain scores in the first 24 hours compared to patients who received thermal radiofrequency neurotomy alone. These patients also used less oral analgesic medication in the post-procedural period. These interventions were carried out by one board accredited pain physician at one center. The procedures were exclusively performed using one model of radiofrequency generator, at one setting for the PDRF and RFA. The difference in the number of levels of ablation was not considered in the analysis of the results. Treating patients with pulsed dose radiofrequency prior to continuous thermal radiofrequency ablation can provide patients with less post-procedural pain during the first 24 hours and also reduce analgesic requirements. Furthermore, the addition of PDRF to standard thermal RFA did not prolong the time of standard thermal radiofrequency ablation procedures, as it was performed during the typically allotted time for local anesthetic action. Low back pain, facet joint disease, medial branch block, Radiofrequency ablation, thermal radiofrequency, pulsed dose radiofrequency, PDRF, zygapophyseal joint.
2017-01-01
Background: The skin tightening effects induced by non-insulated microneedle radiofrequency have proved long-lasting. Our previous three-dimensional volumetric assessment showed significant facial tightening for up to six months. However, nasal and peri-oral tightening effects lasted longer. The objective of this study was to investigate the distribution of the long-term volumetric reduction in facial area induced by a single fractional non-insulated microneedle radiofrequency treatment. Methods: Fifteen Asian patients underwent full facial skin tightening using a sharply tapered non-insulated microneedle radiofrequency applicator with a novel fractionated pulse mode. Three-dimensional volumetric assessments were performed at six and 12 months post-treatment. Patients rated their satisfaction using a 5-point scale at each follow up. Results: Objective assessments with superimposed three-dimensional color images showed significant volumetric reduction in the nasal and peri-oral areas at 12 months post-treatment in all patients. Median volumetric reductions at six and 12 months post-treatment were 13.1 and 12.3ml, respectively. All of the patients were satisfied with their results 12 months post-treatment. Side effects were not observed. Conclusions: This single fractional NIMNRF treatment provided long-lasting nasal and peri-oral tightening as shown via 3D volumetric assessment. Moreover, NIMNRF produced minimal complications, downtime, and few side effects. This approach provides safe and effective treatment of skin tightening. PMID:28367261
The public multi-coil information (PUMCIN) policy.
Juchem, Christoph; de Graaf, Robin A
2017-11-01
Multi-coil (MC) magnetic field modeling has emerged as a viable alternative to conventional field generation based on spherical harmonic shapes, and an active MC community is forming. Although all MC applications share the same modeling concept, the specific MC designs can largely differ as a result of disparities in region of interest (eg, human versus rodent), intended MR application (eg, B 0 shimming versus spatial encoding), or other experimental constraints (eg, available bore space or integration with radiofrequency technology). To date, a lack of detailed information on existing MC designs complicates the assessment and precludes a meaningful comparison. Here, we suggest that future publications involving the MC technique not only report the benefits for the application at hand, but also include an explicit description of the MC wire pattern used. This public multi-coil information (PUMCIN) policy represents a voluntary commitment to promoting free public access to the details necessary for reproducing and benefiting from MC research. The PUMCIN policy is expected to initiate a paradigm shift with respect to the way MC innovation is reported. By setting an example, we hope to encourage the evolving MC community to maximize the benefits for science and society by embracing it. Magn Reson Med 78:2042-2047, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Federal Communications Commission Semiannual Regulatory Agenda
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-20
...) 3060-AH65 510 Exposure to Radiofrequency Electromagnetic Fields 3060-AI17 511 Unlicensed Operation in...; Wireless 46.9-47 GHz; Government Operations 37-38 & 40 517 Streamlining Earth Station Licensing Rules (IB... 2025 MHz, and 2175 to 2180 MHz Bands 578 Rules Authorizing the Operation of Low Power Auxiliary...
Gated Field-Emission Cathode Radio-Frequency (RF) Gun
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fermi Research Alliance, Fermi Alliance
The goal of this CRADA was to procure the carbon nanotube cathode from Radiabeam, install it in HBESL and make current measurements as a function of the gun gradient. The gun was operated at 1.3 GHz. After testing, send the cathode back to RadiaBeam for surface analysis.
Energetic ion mass analysis using a radio-frequency quadrupole filter.
Medley, S S
1978-06-01
In conventional applications of the radio-frequency quadrupole mass analyzer, the ion injection energy is usually limited to less than the order of 100 eV due to constraints on the dimensions and power supply of the device. However, requirements often arise, for example in fusion plasma ion diagnostics, for mass analysis of much more energetic ions. A technique easily adaptable to any conventional quadrupole analyzer which circumvents the limitation on injection energy is documented in this paper. Briefly, a retarding potential applied to the pole assembly is shown to facilitate mass analysis of multikiloelectron volt ions without altering the salient characteristics of either the quadrupole filter or the ion beam.
NASA Astrophysics Data System (ADS)
Hu, Xiaolin; Aggarwal, Kamal; Yang, Mimi X.; Parizi, Kokab B.; Xu, Xiaoqing; Akin, Demir; Poon, Ada S. Y.; Wong, H.-S. Philip
2017-07-01
We report the design, analysis, and characterization of a three-inductor radio-frequency identification (RFID) and transceiver system for potential applications in individual cell tracking and monitoring. The RFID diameter is 22 μ m and can be naturally internalized by living cells. Using magnetic resonance coupling, the system shows resonance shifts when the RFID is present and also when the RFID loading capacitance changes. It operates at 60 GHz with a high signal magnitude up to -50 dB and a sensitivity of 0.2. This miniaturized RFID with a high signal magnitude is a promising step toward continuous, real-time monitoring of activities at cellular levels.
Wireless communication with implanted medical devices using the conductive properties of the body.
Ferguson, John E; Redish, A David
2011-07-01
Many medical devices that are implanted in the body use wires or wireless radiofrequency telemetry to communicate with circuitry outside the body. However, the wires are a common source of surgical complications, including breakage, infection and electrical noise. In addition, radiofrequency telemetry requires large amounts of power and results in low-efficiency transmission through biological tissue. As an alternative, the conductive properties of the body can be used to enable wireless communication with implanted devices. In this article, several methods of intrabody communication are described and compared. In addition to reducing the complications that occur with current implantable medical devices, intrabody communication can enable novel types of miniature devices for research and clinical applications.
NASA Astrophysics Data System (ADS)
Wagenaars, E.; Gans, T.; O'Connell, D.; Niemi, K.
2012-08-01
The first direct measurements of atomic nitrogen species in a radio-frequency atmospheric-pressure plasma jet (APPJ) are presented. Atomic nitrogen radicals play a key role in new plasma medicine applications of APPJs. The measurements were performed with a two-photon absorption laser-induced fluorescence diagnostic, using 206.65 nm laser photons for the excitation of ground-state N atoms and observing fluorescence light around 744 nm. The APPJ was run with a helium gas flow of 1 slm and varying small admixtures of molecular nitrogen of 0-0.7 vol%. A maximum in the measured N concentration was observed for an admixture of 0.25 vol% N2.
47 CFR 2.807 - Statutory exceptions.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Carriers transporting radiofrequency devices without trading in them. (b) Radiofrequency devices manufactured solely for export. (c) The manufacture, assembly, or installation of radiofrequency devices for... device shall be operated if it causes harmful interference to radio communications. (d) Radiofrequency...
Emerging needle ablation technology in urology.
Leveillee, Raymond J; Pease, Karli; Salas, Nelson
2014-01-01
Thermal ablation of urologic tumors in the form of freezing (cryoablation) and heating (radiofrequency ablation) have been utilized successfully to treat and ablate soft tissue tumors for over 15 years. Multiple studies have demonstrated efficacy nearing that of extirpative surgery for certain urologic conditions. There are technical limitations to their speed and safety profile because of the physical limits of thermal diffusion. Recently, there has been a desire to investigate other forms of energy in an effort to circumvent the limitations of cryoblation and radiofrequency ablation. This review will focus on three relatively new energy applications as they pertain to tissue ablation: microwave, irreversible electroporation, and water vapor. High-intensity-focused ultrasound nor interstitial lasers are discussed, as there have been no recently published updates. Needle and probe-based ablative treatments will continue to play an important role. As three-dimensional imaging workstations move from the advanced radiologic interventional suite to the operating room, surgeons will likely still play a pivotal role in the +-application of these probe ablative devices. It is essential that the surgeon understands the fundamentals of these devices in order to optimize their application.
Predicting nurses' acceptance of radiofrequency identification technology.
Norten, Adam
2012-10-01
The technology of radiofrequency identification allows for the scanning of radiofrequency identification-tagged objects and individuals without line-of-sight requirements. Healthcare organizations use radiofrequency identification to ensure the health and safety of patients and medical personnel and to uncover inefficiencies. Although the successful implementation of a system incorporating radiofrequency identification technologies requires acceptance and use of the technology, some nurses using radiofrequency identification in hospitals feel like "Big Brother" is watching them. This predictive study used a theoretical model assessing the effect of five independent variables: privacy concerns, attitudes, subjective norms, controllability, and self-efficacy, on a dependent variable, nurses' behavioral intention to use radiofrequency identification. A Web-based questionnaire containing previously validated questions was answered by 106 US RNs. Multiple linear regression showed that all constructs together accounted for 60% of the variance in nurses' intention to use radiofrequency identification. Of the predictors in the model, attitudes provided the largest unique contribution when the other predictors in the model were held constant; subjective norms also provided a unique contribution. Privacy concerns, controllability, and self-efficacy did not provide a significant contribution to nurses' behavioral intention to use radiofrequency identification.
Lendvai, Ádám Z; Akçay, Çağlar; Weiss, Talia; Haussmann, Mark F; Moore, Ignacio T; Bonier, Frances
2015-01-01
Playbacks of visual or audio stimuli to wild animals is a widely used experimental tool in behavioral ecology. In many cases, however, playback experiments are constrained by observer limitations such as the time observers can be present, or the accuracy of observation. These problems are particularly apparent when playbacks are triggered by specific events, such as performing a specific behavior, or are targeted to specific individuals. We developed a low-cost automated playback/recording system, using two field-deployable devices: radio-frequency identification (RFID) readers and Raspberry Pi micro-computers. This system detects a specific passive integrated transponder (PIT) tag attached to an individual, and subsequently plays back the stimuli, or records audio or visual information. To demonstrate the utility of this system and to test one of its possible applications, we tagged female and male tree swallows (Tachycineta bicolor) from two box-nesting populations with PIT tags and carried out playbacks of nestling begging calls every time focal females entered the nestbox over a six-hour period. We show that the RFID-Raspberry Pi system presents a versatile, low-cost, field-deployable system that can be adapted for many audio and visual playback purposes. In addition, the set-up does not require programming knowledge, and it easily customized to many other applications, depending on the research questions. Here, we discuss the possible applications and limitations of the system. The low cost and the small learning curve of the RFID-Raspberry Pi system provides a powerful new tool to field biologists.
Akçay, Çağlar; Weiss, Talia; Haussmann, Mark F.; Moore, Ignacio T.; Bonier, Frances
2015-01-01
Playbacks of visual or audio stimuli to wild animals is a widely used experimental tool in behavioral ecology. In many cases, however, playback experiments are constrained by observer limitations such as the time observers can be present, or the accuracy of observation. These problems are particularly apparent when playbacks are triggered by specific events, such as performing a specific behavior, or are targeted to specific individuals. We developed a low-cost automated playback/recording system, using two field-deployable devices: radio-frequency identification (RFID) readers and Raspberry Pi micro-computers. This system detects a specific passive integrated transponder (PIT) tag attached to an individual, and subsequently plays back the stimuli, or records audio or visual information. To demonstrate the utility of this system and to test one of its possible applications, we tagged female and male tree swallows (Tachycineta bicolor) from two box-nesting populations with PIT tags and carried out playbacks of nestling begging calls every time focal females entered the nestbox over a six-hour period. We show that the RFID-Raspberry Pi system presents a versatile, low-cost, field-deployable system that can be adapted for many audio and visual playback purposes. In addition, the set-up does not require programming knowledge, and it easily customized to many other applications, depending on the research questions. Here, we discuss the possible applications and limitations of the system. The low cost and the small learning curve of the RFID-Raspberry Pi system provides a powerful new tool to field biologists. PMID:25870771
Kim, Nam-Young; Adhikari, Kishor Kumar; Dhakal, Rajendra; Chuluunbaatar, Zorigt; Wang, Cong; Kim, Eun-Soo
2015-01-15
Tremendous demands for sensitive and reliable label-free biosensors have stimulated intensive research into developing miniaturized radiofrequency resonators for a wide range of biomedical applications. Here, we report the development of a robust, reusable radiofrequency resonator based integrated passive device biosensor chip fabricated on a gallium arsenide substrate for the detection of glucose in water-glucose solutions and sera. As a result of the highly concentrated electromagnetic energy between the two divisions of an intertwined spiral inductor coupled with an interdigital capacitor, the proposed glucose biosensor chip exhibits linear detection ranges with high sensitivity at center frequency. This biosensor, which has a sensitivity of up to 199 MHz/mgmL(-1) and a short response time of less than 2 sec, exhibited an ultralow detection limit of 0.033 μM and a reproducibility of 0.61% relative standard deviation. In addition, the quantities derived from the measured S-parameters, such as the propagation constant (γ), impedance (Z), resistance (R), inductance (L), conductance (G) and capacitance (C), enabled the effective multi-dimensional detection of glucose.
Body-contouring with radiofrequency-assisted liposuction.
Ion, Lucian; Raveendran, Sherine S; Fu, Brian
2011-12-01
Liposculpturing is the most frequently performed procedure in the aesthetic clinical practice. The techniques have evolved into significant modification during the past few decades with introduction of several new devices, leading to superior outcome. Radiofrequency-assisted liposuction (RFAL) have revolutionised body contouring techniques by providing simultaneous fat liquefaction, coagulation of blood vessels, and skin tightening in the tissues. In this study we discuss our preliminary experience with RFAL in treating patients for aesthetic body contouring and patients with HIV-related lipohypertrophy. Forty-two patients were treated with RFAL for cosmetic concerns, and eight were treated for HIV-related lipohypertrophy after unsuccessful outcome with other techniques. Significant reduction of adipose tissue with marked tightening of the skin was noted in all the patients. Clinical results were impressive in terms of pain, recovery, and patient satisfaction. Remarkable improvement was observed in patients with HIV-related cervical lipohypertrophy and gynaecomastia with fibrous fatty tissue. Two patients suffered superficial burns and were managed conservatively. Our experience suggests that controlled application of radiofrequency power for liposculpturing may open up a new horizon of non-excisional lipectomy in the future.
Kim, Nam-Young; Adhikari, Kishor Kumar; Dhakal, Rajendra; Chuluunbaatar, Zorigt; Wang, Cong; Kim, Eun-Soo
2015-01-01
Tremendous demands for sensitive and reliable label-free biosensors have stimulated intensive research into developing miniaturized radiofrequency resonators for a wide range of biomedical applications. Here, we report the development of a robust, reusable radiofrequency resonator based integrated passive device biosensor chip fabricated on a gallium arsenide substrate for the detection of glucose in water-glucose solutions and sera. As a result of the highly concentrated electromagnetic energy between the two divisions of an intertwined spiral inductor coupled with an interdigital capacitor, the proposed glucose biosensor chip exhibits linear detection ranges with high sensitivity at center frequency. This biosensor, which has a sensitivity of up to 199 MHz/mgmL−1 and a short response time of less than 2 sec, exhibited an ultralow detection limit of 0.033 μM and a reproducibility of 0.61% relative standard deviation. In addition, the quantities derived from the measured S-parameters, such as the propagation constant (γ), impedance (Z), resistance (R), inductance (L), conductance (G) and capacitance (C), enabled the effective multi-dimensional detection of glucose. PMID:25588958
Heating of cardiovascular stents in intense radiofrequency magnetic fields.
Foster, K R; Goldberg, R; Bonsignore, C
1999-01-01
We consider the heating of a metal stent in an alternating magnetic field from an induction heating furnace. An approximate theoretical analysis is conducted to estimate the magnetic field strength needed to produce substantial temperature increases. Experiments of stent heating in industrial furnaces are reported, which confirm the model. The results show that magnetic fields inside inductance furnaces are capable of significantly heating stents. However, the fields fall off very quickly with distance and in most locations outside the heating coil, field levels are far too small to produce significant heating. The ANSI/IEEE C95.1-1992 limits for human exposure to alternating magnetic fields provide adequate protection against potential excessive heating of the stents.
Number Codes Readable by Magnetic-Field-Response Recorders
NASA Technical Reports Server (NTRS)
Woodard, Stanley E.; Taylor,Bryant D.
2009-01-01
A method of encoding and reading numbers incorporates some of the features of conventional optical bar coding and radio-frequency identification (RFID) tagging, but overcomes some of the disadvantages of both: (1) Unlike in conventional optical bar coding, numbers can be read without having a line of sight to a tag; and (2) the tag circuitry is simpler than the circuitry used in conventional RFID. The method is based largely on the principles described in Magnetic-Field-Response Measurement-Acquisition System (LAR-16908), NASA Tech Briefs, Vol. 30, No. 6 (June 2006) page 28. To recapitulate: A noncontact system includes a monitoring unit that acquires measurements from sensors at distances of the order of several meters. Each sensor is a passive radio-frequency (RF) resonant circuit in the form of one or more inductor(s) and capacitor(s). The monitoring unit a handheld unit denoted a magnetic field response recorder (MFRR) generates an RF magnetic field that excites oscillations in the resonant circuits resulting in the sensors responding with their own radiated magnetic field. The resonance frequency of each sensor is made to differ significantly from that of the other sensors to facilitate distinction among the responses of different sensors. The MFRR measures selected aspects of the sensor responses: in a typical application, the sensors are designed so that their resonance frequencies vary somewhat with the sensed physical quantities and, accordingly, the MFRR measures the resonance frequencies and variations thereof as indications of those quantities. In the present method, the resonance circuits are not used as sensors. Instead, the circuits are made to resonate at fixed frequencies that correspond to digits to be encoded. The number-encoding scheme is best explained by means of examples in which each resonant circuit consists of a spiral trace inductor electrically connected to a set of parallel-connected capacitors in the form of interdigitated electrode pairs (see figure). The inductor and capacitor(s) in each resonant circuit can be fabricated as a patterned thin metal film by means of established metal-deposition and -patterning techniques. The capacitance and, hence, the resonance frequency, depends on the number of interdigitated electrodes connected to the inductor. In a similar manner, sets of electrodes could be used.
Pachón-García, F T; Paniagua-Sánchez, J M; Rufo-Pérez, M; Jiménez-Barco, A
2014-12-01
This article analyses the electric field levels around medium-wave transmitters, delimiting the temporal variability of the levels received at a pre-established reception point. One extensively used dosimetric criterion is to consider historical levels of the field recorded over a certain period of time so as to provide an overall perspective of radio-frequency electric field exposure in a particular environment. This aspect is the focus of the present study, in which the measurements will be synthesised in the form of exposure coefficients. Two measurement campaigns were conducted: one short term (10 days) and the other long term (1 y). The short-term data were used to study which probability density functions best approximate the measured levels. The long-term data were used to compute the principal statistics that characterise the field values over a year. The data that form the focus of the study are the peak traces, since these are the most representative from the standpoint of exposure. The deviations found were around 6 % for short periods and 12 % for long periods. The information from the two campaigns was used to develop and implement a computer application based on the Monte Carlo method to simulate values of the field, allowing one to carry out robust statistics. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
21 CFR 882.4400 - Radiofrequency lesion generator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion generator. 882.4400 Section... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4400 Radiofrequency lesion generator. (a) Identification. A radiofrequency lesion generator is a device used to produce...
Poly(caprolactone) based magnetic scaffolds for bone tissue engineering
NASA Astrophysics Data System (ADS)
Bañobre-López, M.; Piñeiro-Redondo, Y.; De Santis, R.; Gloria, A.; Ambrosio, L.; Tampieri, A.; Dediu, V.; Rivas, J.
2011-04-01
Synthetic scaffolds for tissue engineering coupled to stem cells represent a promising approach aiming to promote the regeneration of large defects of damaged tissues or organs. Magnetic nanocomposites formed by a biodegradable poly(caprolactone) (PCL) matrix and superparamagnetic iron doped hydroxyapatite (FeHA) nanoparticles at different PCL/FeHA compositions have been successfully prototyped, layer on layer, through 3D bioplotting. Magnetic measurements, mechanical testing, and imaging were carried out to calibrate both model and technological processing in the magnetized scaffold prototyping. An amount of 10% w/w of magnetic FeHA nanoparticles represents a reinforcement for PCL matrix, however, a reduction of strain at failure is also observed. Energy loss (absorption) measurements under a radio-frequency applied magnetic field were performed in the resulting magnetic scaffolds and very promising heating properties were observed, making them very useful for potential biomedical applications.
Macroscopic self-reorientation of interacting two-dimensional crystals
Woods, C. R.; Withers, F.; Zhu, M. J.; Cao, Y.; Yu, G.; Kozikov, A.; Ben Shalom, M.; Morozov, S. V.; van Wijk, M. M.; Fasolino, A.; Katsnelson, M. I.; Watanabe, K.; Taniguchi, T.; Geim, A. K.; Mishchenko, A.; Novoselov, K. S.
2016-01-01
Microelectromechanical systems, which can be moved or rotated with nanometre precision, already find applications in such fields as radio-frequency electronics, micro-attenuators, sensors and many others. Especially interesting are those which allow fine control over the motion on the atomic scale because of self-alignment mechanisms and forces acting on the atomic level. Such machines can produce well-controlled movements as a reaction to small changes of the external parameters. Here we demonstrate that, for the system of graphene on hexagonal boron nitride, the interplay between the van der Waals and elastic energies results in graphene mechanically self-rotating towards the hexagonal boron nitride crystallographic directions. Such rotation is macroscopic (for graphene flakes of tens of micrometres the tangential movement can be on hundreds of nanometres) and can be used for reproducible manufacturing of aligned van der Waals heterostructures. PMID:26960435
Eghlidospour, Mahsa; Ghanbari, Amir
2017-01-01
Due to the importance of neural stem cells (NSCs) in plasticity of the nervous system and treating neurodegenerative diseases, the main goal of this study was to evaluate the effects of radiofrequency radiation emitted from a GSM 900-MHz mobile phone with different exposure duration on proliferation, differentiation and apoptosis of adult murine NSCs in vitro. We used neurosphere assay to evaluate NSCs proliferation, and immunofluorescence assay of neural cell markers to examine NSCs differentiation. We also employed alamarBlue and caspase 3 apoptosis assays to assess harmful effects of mobile phone on NSCs. Our results showed that the number and size of resulting neurospheres and also the percentage of cells differentiated into neurons decreased significantly with increasing exposure duration to GSM 900-MHz radiofrequency (RF)-electromagnetic field (EMF). In contrast, exposure to GSM 900-MHz RF-EMF at different durations did not influence cell viability and apoptosis of NSCs and also their astrocytic differentiation. It is concluded that accumulating dose of GSM 900-MHz RF-EMF might have devastating effects on NSCs proliferation and neurogenesis requiring more causations in terms of using mobile devices. PMID:28713615
Eghlidospour, Mahsa; Ghanbari, Amir; Mortazavi, Seyyed Mohammad Javad; Azari, Hassan
2017-06-01
Due to the importance of neural stem cells (NSCs) in plasticity of the nervous system and treating neurodegenerative diseases, the main goal of this study was to evaluate the effects of radiofrequency radiation emitted from a GSM 900-MHz mobile phone with different exposure duration on proliferation, differentiation and apoptosis of adult murine NSCs in vitro . We used neurosphere assay to evaluate NSCs proliferation, and immunofluorescence assay of neural cell markers to examine NSCs differentiation. We also employed alamarBlue and caspase 3 apoptosis assays to assess harmful effects of mobile phone on NSCs. Our results showed that the number and size of resulting neurospheres and also the percentage of cells differentiated into neurons decreased significantly with increasing exposure duration to GSM 900-MHz radiofrequency (RF)-electromagnetic field (EMF). In contrast, exposure to GSM 900-MHz RF-EMF at different durations did not influence cell viability and apoptosis of NSCs and also their astrocytic differentiation. It is concluded that accumulating dose of GSM 900-MHz RF-EMF might have devastating effects on NSCs proliferation and neurogenesis requiring more causations in terms of using mobile devices.
Effects of 900 MHz radiofrequency radiation on skin hydroxyproline contents.
Çam, Semra Tepe; Seyhan, Nesrin; Kavaklı, Cengiz; Çelikbıçak, Ömür
2014-09-01
The present study aimed to investigate the possible effect of pulse-modulated radiofrequency radiation (RFR) on rat skin hydroxyproline content, since skin is the first target of external electromagnetic fields. Skin hydroxyproline content was measured using liquid chromatography mass spectrometer method. Two months old male wistar rats were exposed to a 900 MHz pulse-modulated RFR at an average whole body specific absorption rate (SAR) of 1.35 W/kg for 20 min/day for 3 weeks. The radiofrequency (RF) signals were pulse modulated by rectangular pulses with a repetition frequency of 217 Hz and a duty cycle of 1:8 (pulse width 0.576 ms). A skin biopsy was taken at the upper part of the abdominal costa after the exposure. The data indicated that whole body exposure to a pulse-modulated RF radiation that is similar to that emitted by the global system for mobile communications (GSM) mobile phones caused a statistically significant increase in the skin hydroxyproline level (p = 0.049, Mann-Whitney U test). Under our experimental conditions, at a SAR less than the International Commission on Non-Ionizing Radiation Protection safety limit recommendation, there was evidence that GSM signals could alter hydroxyproline concentration in the rat skin.
Zeleke, Berihun M.; Abramson, Michael J.; Benke, Geza
2018-01-01
Uncertainty in experimental studies of exposure to radiation from mobile phones has in the past only been framed within the context of statistical variability. It is now becoming more apparent to researchers that epistemic or reducible uncertainties can also affect the total error in results. These uncertainties are derived from a wide range of sources including human error, such as data transcription, model structure, measurement and linguistic errors in communication. The issue of epistemic uncertainty is reviewed and interpreted in the context of the MoRPhEUS, ExPOSURE and HERMES cohort studies which investigate the effect of radiofrequency electromagnetic radiation from mobile phones on memory performance. Research into this field has found inconsistent results due to limitations from a range of epistemic sources. Potential analytic approaches are suggested based on quantification of epistemic error using Monte Carlo simulation. It is recommended that future studies investigating the relationship between radiofrequency electromagnetic radiation and memory performance pay more attention to treatment of epistemic uncertainties as well as further research into improving exposure assessment. Use of directed acyclic graphs is also encouraged to display the assumed covariate relationship. PMID:29587425
Wireless-powered electroactive soft microgripper
NASA Astrophysics Data System (ADS)
Cheong, Hau Ran; Teo, Choon Yee; Leow, Pei Ling; Lai, Koon Chun; Chee, Pei Song
2018-05-01
This paper presents a wireless powered single active finger ionic polymer metal composite (IPMC) based microgripper that is operated using external radio-frequency (RF) magnetic field for biological cell manipulation application. A unimorph-like active finger is fabricated by integrating the IPMC actuator to the planar resonant LC receiver and DC rectifier circuits (made of flexible double-sided copper clad polyimide). The finger activated when the device is exposed to the external magnetic field generated by transmitter circuit that matches the resonant frequency of LC receiver circuit, ∼13.6 MHz in magnetic resonant coupling power transfer mechanism. The fabricated prototype shows a maximum IPMC deflection of 0.765 mm (activation force of 0.17 mN) at the RF power of 0.65 W with 3.5 VDC supplied from the LC receiver circuit. Three repeated ON-OFF wireless activation cycle was performed with the reported cumulative deflection of 0.57 mm. The cumulative deflection was increased to 1.17 mm, 1.19 mm and 1.24 mm for three different samples respectively at 5 VDC supplied. As a proof of concept, fish egg was used to represent the biological cell manipulation operation. The microgripper successfully gripped the fish egg sample without any damages. The experiments result validates the effectiveness of wireless RF soft microgripper towards the target application.
NASA Astrophysics Data System (ADS)
Hellwagner, Johannes; Sharma, Kshama; Tan, Kong Ooi; Wittmann, Johannes J.; Meier, Beat H.; Madhu, P. K.; Ernst, Matthias
2017-06-01
Pulse imperfections like pulse transients and radio-frequency field maladjustment or inhomogeneity are the main sources of performance degradation and limited reproducibility in solid-state nuclear magnetic resonance experiments. We quantitatively analyze the influence of such imperfections on the performance of symmetry-based pulse sequences and describe how they can be compensated. Based on a triple-mode Floquet analysis, we develop a theoretical description of symmetry-based dipolar recoupling sequences, in particular, R2 6411, calculating first- and second-order effective Hamiltonians using real pulse shapes. We discuss the various origins of effective fields, namely, pulse transients, deviation from the ideal flip angle, and fictitious fields, and develop strategies to counteract them for the restoration of full transfer efficiency. We compare experimental applications of transient-compensated pulses and an asynchronous implementation of the sequence to a supercycle, SR26, which is known to be efficient in compensating higher-order error terms. We are able to show the superiority of R26 compared to the supercycle, SR26, given the ability to reduce experimental error on the pulse sequence by pulse-transient compensation and a complete theoretical understanding of the sequence.
Interventional Oncology in Hepatocellular Carcinoma: Progress Through Innovation.
Mu, Lin; Chapiro, Julius; Stringam, Jeremiah; Geschwind, Jean-François
The clinical management of hepatocellular carcinoma has evolved greatly in the last decade mostly through recent technical innovations. In particular, the application of cutting-edge image guidance has led to minimally invasive solutions for complex clinical problems and rapid advances in the field of interventional oncology. Many image-guided therapies, such as transarterial chemoembolization and radiofrequency ablation, have meanwhile been fully integrated into interdisciplinary clinical practice, whereas others are currently being investigated. This review summarizes and evaluates the most relevant completed and ongoing clinical trials, provides a synopsis of recent innovations in the field of intraprocedural imaging and tumor response assessment, and offers an outlook on new technologies, such as radiopaque embolic materials. In addition, combination therapies consisting of locoregional therapies and systemic molecular targeted agents (e.g., sorafenib) remain of major interest to the field and are also discussed. Finally, we address the many substantial advances in immune response pathways that have been related to the systemic effects of locoregional therapies. Knowledge of these new developments is crucial as they continue to shape the future of cancer treatment, further establishing interventional oncology along with surgical, medical, and radiation oncology as the fourth pillar of cancer care.
Foster, J.S. Jr.
1958-03-11
This patent describes apparatus for producing an electricity neutral ionized gas discharge, termed a plasma, substantially free from contamination with neutral gas particles. The plasma generator of the present invention comprises a plasma chamber wherein gas introduced into the chamber is ionized by a radiofrequency source. A magnetic field is used to focus the plasma in line with an exit. This magnetic field cooperates with a differential pressure created across the exit to draw a uniform and uncontaminated plasma from the plasma chamber.
The response of human bacteria to static magnetic field and radiofrequency electromagnetic field.
Crabtree, David P E; Herrera, Brandon J; Kang, Sanghoon
2017-10-01
Cell phones and electronic appliances and devices are inseparable from most people in modern society and the electromagnetic field (EMF) from the devices is a potential health threat. Although the direct health effect of a cell phone and its radiofrequency (RF) EMF to human is still elusive, the effect to unicellular organisms is rather apparent. Human microbiota, including skin microbiota, has been linked to a very significant role in the health of a host human body. It is important to understand the response of human skin microbiota to the RF-EMF from cell phones and personal electronic devices, since this may be one of the potential mechanisms of a human health threat brought about by the disruption of the intimate and balanced host-microbiota relationship. Here, we investigated the response of both laboratory culture strains and isolates of skin bacteria under static magnetic field (SMF) and RF-EMF. The growth patterns of laboratory cultures of Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus epidermidis under SMF were variable per different species. The bacterial isolates of skin microbiota from 4 subjects with different cell phone usage history also showed inconsistent growth responses. These findings led us to hypothesize that cell phone level RF-EMF disrupts human skin microbiota. Thus, the results from the current study lay ground for more comprehensive research on the effect of RF-EMF on human health through the human-microbiota relationship.
Finnie, John W; Cai, Zhao; Manavis, Jim; Helps, Stephen; Blumbergs, Peter C
2010-02-01
To determine whether acute or long-term exposure of the brain to mobile telephone radiofrequency (RF) fields produces activation of microglia, which normally respond rapidly to any change in their microenvironment. Using a purpose designed exposure system at 900 MHz, mice were given a single, far-field whole body exposure at a specific absorption rate (SAR) of 4 W/kg for 60 min (acute) or on five successive days per week for 104 weeks (long-term). Control mice were sham-exposed or freely mobile in a cage to control for any stress caused by immobilisation in the exposure module. Positive control brains subjected to a stab wound were also included to confirm the ability of microglia to react to any neural stress. Brains were perfusion-fixed with 4% paraformaldehyde and representative regions of the cerebral cortex and hippocampus immunostained for ionised calcium binding adaptor molecule (Iba1), a specific microglial marker. There was no increase in microglial Iba1 expression in brains short or long-term exposed to mobile telephony microwaves compared to control (sham-exposed or freely moving caged mice) brains, while substantial microglial activation occurred in damaged positive control neural tissue. Acute (60 minutes) or longer duration (2 years) exposure of murine brains to mobile telephone RF fields did not produce any microglial activation detectable by Iba1 immunostaining.
Ware, Matthew J; Curtis, Louis T; Wu, Min; Ho, Jason C; Corr, Stuart J; Curley, Steven A; Godin, Biana; Frieboes, Hermann B
2017-06-13
Although chemotherapy combined with radiofrequency exposure has shown promise in cancer treatment by coupling drug cytotoxicity with thermal ablation or thermally-induced cytotoxicity, limited access of the drug to tumor loci in hypo-vascularized lesions has hampered clinical application. We recently showed that high-intensity short-wave capacitively coupled radiofrequency (RF) electric-fields may reach inaccessible targets in vivo. This non-invasive RF combined with gemcitabine (Gem) chemotherapy enhanced drug uptake and effect in pancreatic adenocarcinoma (PDAC), notorious for having poor response and limited therapeutic options, but without inducing thermal injury. We hypothesize that the enhanced cytotoxicity derives from RF-facilitated drug transport in the tumor microenvironment. We propose an integrated experimental/computational approach to evaluate chemotherapeutic response combined with RF-induced phenotypic changes in tissue with impaired transport. Results show that RF facilitates diffusive transport in 3D cell cultures representing hypo-vascularized lesions, enhancing drug uptake and effect. Computational modeling evaluates drug vascular extravasation and diffusive transport as key RF-modulated parameters, with transport being dominant. Assessment of hypothetical schedules following current clinical protocol for Stage-IV PDAC suggests that unresponsive lesions may be growth-restrained when exposed to Gem plus RF. Comparison of these projections to experiments in vivo indicates that synergy may result from RF-induced cell phenotypic changes enhancing drug transport and cytotoxicity, thus providing a potential baseline for clinically-focused evaluation.
NASA Astrophysics Data System (ADS)
Herrojo, Cristian; Mata-Contreras, Javier; Paredes, Ferran; Martín, Ferran
2017-11-01
The data density per surface (DPS) is a figure of merit in chipless radiofrequency identification (chipless-RFID) tags. In this paper, it is demonstrated that chipless-RFID tags with high DPS can be implemented by using double-chains of S-shaped split ring resonators (S-SRRs). Tag reading is achieved by near-field coupling between the tag and the reader, a CPW transmission line fed by a harmonic signal tuned to the resonance frequency of the S-SRRs. By transversally displacing the tag over the CPW, the transmission coefficient of the line is modulated by tag motion. This effectively modulates the amplitude of the injected (carrier) signal at the output port of the line, and the identification (ID) code, determined by the presence or absence of S-SRRs at predefined and equidistant positions in the chains, is contained in the envelope function. The DPS is determined by S-SRR dimensions and by the distance between S-SRRs in the chains. However, by using two chains of S-SRRs, the number of bits per unit length that can be accommodated is very high. This chipless-RFID system is of special interest in applications where the reading distance can be sacrificed in favor of data capacity (e.g., security and authentication). Encoding of corporate documents, ballots, exams, etc., by directly printing the proposed tags on the item product to prevent counterfeiting is envisaged.
Mortazavi, S. M. J.; Rahimi, S.; Talebi, A.; Soleimani, A.; Rafati, A.
2015-01-01
Background: The rapid development of wireless telecommunication technologies over the past decades, has led to significant changes in the exposure of the general public to electromagnetic fields. Nowadays, people are continuously exposed to different sources of electromagnetic fields such as mobile phones, mobile base stations, cordless phones, Wi-Fi routers, and power lines. Therefore, the last decade witnessed a rapidly growing concern about the possible health effects of exposure to electromagnetic fields emitted by these sources. Materials and Methods: In this study that was aimed at investigating the effects of exposure to radiofrequency (RF) radiation emitted by a GSM mobile phone on the pattern of contraction in frog’s isolated gastrocnemius muscle after stimulation with single square pulses of 1V (1 Hz), pulse height of contractions, the time interval between two subsequent contractions and the latency period were measured. Results: Our findings showed that the pulse height of contractions muscle could be affected by the exposure to electromagnetic fields. Especially, the latency period was effectively altered in RF-exposed samples. However, none of the experiments could show an alteration in the time interval between two subsequent contractions after exposure to electromagnetic fields. Conclusion: These findings support early reports which indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians including the effects on the pattern of muscle extractions. PMID:26396968
Federal Communications Commission Semiannual Regulatory Agenda
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-26
... Exposure to Radiofrequency Electromagnetic Fields 3060-AI17 316 Unlicensed Operation in the TV Broadcast... Docket No. 3060-AH75 05-96; ET Docket No. 02-380) 319 Unlicensed Operation of the 3650-3700 Band (ET...-AJ20 MHz, 2020 to 2025 MHz, and 2175 to 2180 MHz Bands 385 Rules Authorizing the Operation of Low Power...
The "Tweeting Book" and the Question of "Non-Human Data"
ERIC Educational Resources Information Center
Knox, Jeremy
2015-01-01
This short article describes an experimental radio-frequency identification (RFID) system designed to playfully explore the possibilities of object agency, in the form of "tweeting books". The use of web-enabled sensors is discussed in the context of the emerging field of Learning Analytics. The analysis of the "tweeting books"…
Mobile Phones, Non-Ionizing Radiofrequency Fields and Brain Cancer: Is There an Adaptive Response?
Vijayalaxmi; Prihoda, Thomas J.
2014-01-01
There is widespread concern among the general public regarding the ever increasing use of mobile phones. The concern is mainly because the antenna which transmits nonionizing radiofrequency fields is held close to the head during use and thus might cause brain cancer. By far, the largest epidemiological study was conducted by the INTER-PHONE study group and the results were published in 2011. The author’s conclusions were (i) no increased risk of meningioma and glioma in mobile phone users and (ii) there were suggestions of an increased risk for glioma at the highest exposure levels but, bias and error prevented a causal interpretation. We have carefully examined all of the odd ratios presented in the INTERPHONE study publication: our results showed 24.3% decreased and 0.7% increased risk for meningioma and 22.1% decreased and 6.6% increased risk for glioma. Hence, we hypothesize that the overwhelming evidence for the decreased risk for both diseases may be due to the induction of ‘adaptive response’ which is well-documented in scientific literature PMID:25249839
Foster, Kenneth R; Glaser, Roland
2007-06-01
This article reviews thermal mechanisms of interaction between radiofrequency (RF) fields and biological systems, focusing on theoretical frameworks that are of potential use in setting guidelines for human exposure to RF energy. Several classes of thermal mechanisms are reviewed that depend on the temperature increase or rate of temperature increase and the relevant dosimetric considerations associated with these mechanisms. In addition, attention is drawn to possible molecular and physiological reactions that could be induced by temperature elevations below 0.1 degrees, which are normal physiological responses to heat, and to the so-called microwave auditory effect, which is a physiologically trivial effect resulting from thermally-induced acoustic stimuli. It is suggested that some reported "nonthermal" effects of RF energy may be thermal in nature; also that subtle thermal effects from RF energy exist but have no consequence to health or safety. It is proposed that future revisions of exposure guidelines make more explicit use of thermal models and empirical data on thermal effects in quantifying potential hazards of RF fields.
Exposure to Radiofrequency Electromagnetic Fields From Wi-Fi in Australian Schools
Karipidis, Ken; Henderson, Stuart; Wijayasinghe, Don; Tjong, Lydiawati; Tinker, Rick
2017-01-01
Abstract The increasing use of Wi-Fi in schools and other places has given rise to public concern that the radiofrequency (RF) electromagnetic fields from Wi-Fi have the potential to adversely affect children. The current study measured typical and peak RF levels from Wi-Fi and other sources in 23 schools in Australia. All of the RF measurements were much lower than the reference levels recommended by international guidelines for protection against established health effects. The typical and peak RF levels from Wi-Fi in locations occupied by children in the classroom were of the order of 10−4 and 10−2% of the exposure guidelines, respectively. Typical RF levels in the classroom were similar between Wi-Fi and radio but higher than other sources. In the schoolyard typical RF levels were higher for radio, TV and mobile phone base stations compared to Wi-Fi. The results of this study showed that the typical RF exposure of children from Wi-Fi at school is very low and comparable or lower to other sources in the environment. PMID:28074013
Exposure to Radiofrequency Electromagnetic Fields From Wi-Fi in Australian Schools.
Karipidis, Ken; Henderson, Stuart; Wijayasinghe, Don; Tjong, Lydiawati; Tinker, Rick
2017-08-01
The increasing use of Wi-Fi in schools and other places has given rise to public concern that the radiofrequency (RF) electromagnetic fields from Wi-Fi have the potential to adversely affect children. The current study measured typical and peak RF levels from Wi-Fi and other sources in 23 schools in Australia. All of the RF measurements were much lower than the reference levels recommended by international guidelines for protection against established health effects. The typical and peak RF levels from Wi-Fi in locations occupied by children in the classroom were of the order of 10-4 and 10-2% of the exposure guidelines, respectively. Typical RF levels in the classroom were similar between Wi-Fi and radio but higher than other sources. In the schoolyard typical RF levels were higher for radio, TV and mobile phone base stations compared to Wi-Fi. The results of this study showed that the typical RF exposure of children from Wi-Fi at school is very low and comparable or lower to other sources in the environment. © The Author 2017. Published by Oxford University Press.
Radiofrequency pulse design in parallel transmission under strict temperature constraints.
Boulant, Nicolas; Massire, Aurélien; Amadon, Alexis; Vignaud, Alexandre
2014-09-01
To gain radiofrequency (RF) pulse performance by directly addressing the temperature constraints, as opposed to the specific absorption rate (SAR) constraints, in parallel transmission at ultra-high field. The magnitude least-squares RF pulse design problem under hard SAR constraints was solved repeatedly by using the virtual observation points and an active-set algorithm. The SAR constraints were updated at each iteration based on the result of a thermal simulation. The numerical study was performed for an SAR-demanding and simplified time of flight sequence using B1 and ΔB0 maps obtained in vivo on a human brain at 7T. The proposed adjustment of the SAR constraints combined with an active-set algorithm provided higher flexibility in RF pulse design within a reasonable time. The modifications of those constraints acted directly upon the thermal response as desired. Although further confidence in the thermal models is needed, this study shows that RF pulse design under strict temperature constraints is within reach, allowing better RF pulse performance and faster acquisitions at ultra-high fields at the cost of higher sequence complexity. Copyright © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Feijoo, Pedro C.; Pasadas, Francisco; Iglesias, José M.; Martín, María J.; Rengel, Raúl; Li, Changfeng; Kim, Wonjae; Riikonen, Juha; Lipsanen, Harri; Jiménez, David
2017-12-01
The quality of graphene in nanodevices has increased hugely thanks to the use of hexagonal boron nitride as a supporting layer. This paper studies to which extent hBN together with channel length scaling can be exploited in graphene field-effect transistors (GFETs) to get a competitive radio-frequency (RF) performance. Carrier mobility and saturation velocity were obtained from an ensemble Monte Carlo simulator that accounted for the relevant scattering mechanisms (intrinsic phonons, scattering with impurities and defects, etc). This information is fed into a self-consistent simulator, which solves the drift-diffusion equation coupled with the two-dimensional Poisson’s equation to take full account of short channel effects. Simulated GFET characteristics were benchmarked against experimental data from our fabricated devices. Our simulations show that scalability is supposed to bring to RF performance an improvement that is, however, highly limited by instability. Despite the possibility of a lower performance, a careful choice of the bias point can avoid instability. Nevertheless, maximum oscillation frequencies are still achievable in the THz region for channel lengths of a few hundreds of nanometers.
Aissani, Sarra; Guendouz, Laouès; Marande, Pierre-Louis; Canet, Daniel
2015-01-01
As demonstrated before, the application of a weak static B0 magnetic field (less than 10 G) may produce definite effects on the ¹⁴N Quadrupole Resonance line when the electric field gradient tensor at the nitrogen nucleus level is of axial symmetry. Here, we address more precisely the problem of the relative orientation of the two magnetic fields (the static field and the radio-frequency field of the pure NQR experiment). For a field of 6G, the evolution of the signal intensity, as a function of this relative orientation, is in very good agreement with the theoretical predictions. There is in particular an intensity loss by a factor of three when going from the parallel configuration to the perpendicular configuration. By contrast, when dealing with a very weak magnetic field (as the earth field, around 0.5 G), this effect drops to ca. 1.5 in the case Hexamethylenetetramine (HMT).This is explained by the fact that the Zeeman shift (due to the very weak magnetic field) becomes comparable to the natural line-width. The latter can therefore be determined by accounting for this competition. Still in the case of HMT, the estimated natural line-width is half the observed line-width. The extra broadening is thus attributed to earth magnetic field. The latter constitutes therefore the main cause of the difference between the natural transverse relaxation time (T₂) and the transverse relaxation time derived from the observed line-width (T₂(⁎)). Copyright © 2015 Elsevier Inc. All rights reserved.
SAR Reduction in 7T C-Spine Imaging Using a “Dark Modes” Transmit Array Strategy
Eryaman, Yigitcan; Guerin, Bastien; Keil, Boris; Mareyam, Azma; Herraiz, Joaquin L.; Kosior, Robert K.; Martin, Adrian; Torrado-Carvajal, Angel; Malpica, Norberto; Hernandez-Tamames, Juan A.; Schiavi, Emanuele; Adalsteinsson, Elfar; Wald, Lawrence L.
2016-01-01
Purpose Local specific absorption rate (SAR) limits many applications of parallel transmit (pTx) in ultra high-field imaging. In this Note, we introduce the use of an array element, which is intentionally inefficient at generating spin excitation (a “dark mode”) to attempt a partial cancellation of the electric field from those elements that do generate excitation. We show that adding dipole elements oriented orthogonal to their conventional orientation to a linear array of conventional loop elements can lower the local SAR hotspot in a C-spine array at 7 T. Methods We model electromagnetic fields in a head/torso model to calculate SAR and excitation B1+ patterns generated by conventional loop arrays and loop arrays with added electric dipole elements. We utilize the dark modes that are generated by the intentional and inefficient orientation of dipole elements in order to reduce peak 10g local SAR while maintaining excitation fidelity. Results For B1+ shimming in the spine, the addition of dipole elements did not significantly alter the B1+ spatial pattern but reduced local SAR by 36%. Conclusion The dipole elements provide a sufficiently complimentary B1+ and electric field pattern to the loop array that can be exploited by the radiofrequency shimming algorithm to reduce local SAR. PMID:24753012
Staudt, Michael D; Maturu, Sarita; Miller, Jonathan P
2018-02-16
Radiofrequency thermocoagulation of epileptogenic foci via stereoelectroencephalography (SEEG) electrodes has been suggested as a treatment for medically intractable epilepsy, but reported outcomes have been suboptimal, possibly because lesions generated using conventional high-energy radiofrequency parameters are relatively small. To describe a technique of delivering low energy across separate SEEG electrodes in order to create large confluent radiofrequency lesions. The size and configuration of radiofrequency lesions using different radiofrequency intensity and interelectrode distance was assessed in egg whites. Magnetic resonance images (MRI) from 3 patients who had undergone radiofrequency lesion creation were evaluated to determine the contribution of lesion intensity and electrode separation on lesion size. Electroencephalography, MRI, and clinical data were assessed before and after lesion creation. Both in Vitro and in Vivo analysis revealed that less energy paradoxically produced larger lesions, with the largest possible lesions produced when radiofrequency power was applied for long duration at less than 3 W. Linear separation of electrodes also contributed to lesion size, with largest lesions produced when electrodes were separated by a linear distance of between 5 and 12 mm. Clinical lesions produced using these parameters were large and resulted in improvement in interictal and ictal activity. Radiofrequency lesions produced using low-energy delivery between SEEG electrodes in close proximity can produce a large lesion. These findings might have advantages for treatment of focal epilepsy.
Hu, Rongwei; Mun, Eun Deok; Altarawneh, M. M.; ...
2012-02-13
The upper critical fields H c2(T) of single crystals of Sr 1-xEu x(Fe₀.₈₉Co₀.₁₁)₂As₂ (x=0.20 and 0.46) were determined by radio-frequency penetration depth measurements in pulsed magnetic fields. H c2(T) approaches the Pauli limiting field but shows an upward curvature with an enhancement from the orbital limited field, as inferred from the Werthamer-Helfand-Hohenberg theory. We discuss the temperature dependence of the upper critical fields and the decreasing anisotropy using a two-band BCS model.
Exploring Non-Thermal Radiofrequency Bioeffects for Novel Military Applications
2006-11-30
catecholamine release, using cultured adrenal chromaffin cells as an i,i vitro model system, and on skeletal muscle contraction , using intact skeletal...characterization and construction of a waveguide-based exposure system for monitoring skeletal muscle contraction during exposure to 0.75-1 GHz RF
Radiofrequency ablation for hepatic hemangiomas: A consensus from a Chinese panel of experts
Gao, Jun; Fan, Rui-Fang; Yang, Jia-Yin; Cui, Yan; Ji, Jian-Song; Ma, Kuan-Sheng; Li, Xiao-Long; Zhang, Long; Xu, Chong-Liang; Kong, Xin-Liang; Ke, Shan; Ding, Xue-Mei; Wang, Shao-Hong; Yang, Meng-Meng; Song, Jin-Jin; Zhai, Bo; Nin, Chun-Ming; Guo, Shi-Gang; Xin, Zong-Hai; Lu, Jun; Dong, Yong-Hong; Zhu, Hua-Qiang; Sun, Wen-Bing
2017-01-01
Recent studies have shown that radiofrequency (RF) ablation therapy is a safe, feasible, and effective procedure for hepatic hemangiomas, even huge hepatic hemangiomas. RF ablation has the following advantages in the treatment of hepatic hemangiomas: minimal invasiveness, definite efficacy, high safety, fast recovery, relatively simple operation, and wide applicability. It is necessary to formulate a widely accepted consensus among the experts in China who have extensive expertise and experience in the treatment of hepatic hemangiomas using RF ablation, which is important to standardize the application of RF ablation for the management of hepatic hemangiomas, regarding the selection of patients with suitable indications to receive RF ablation treatment, the technical details of the techniques, therapeutic effect evaluations, management of complications, etc. A final consensus by a Chinese panel of experts who have the expertise of using RF ablation to treat hepatic hemangiomas was reached by means of literature review, comprehensive discussion, and draft approval. PMID:29093616
Zhou, Nanjia; Liu, Chengye; Lewis, Jennifer A; Ham, Donhee
2017-04-01
Radio-frequency (RF) electronics, which combine passive electromagnetic devices and active transistors to generate and process gigahertz (GHz) signals, provide a critical basis of ever-pervasive wireless networks. While transistors are best realized by top-down fabrication, relatively larger electromagnetic passives are within the reach of printing techniques. Here, direct writing of viscoelastic silver-nanoparticle inks is used to produce a broad array of RF passives operating up to 45 GHz. These include lumped devices such as inductors and capacitors, and wave-based devices such as transmission lines, their resonant networks, and antennas. Moreover, to demonstrate the utility of these printed RF passive structures in active RF electronic circuits, they are combined with discrete transistors to fabricate GHz self-sustained oscillators and synchronized oscillator arrays that provide RF references, and wireless transmitters clocked by the oscillators. This work demonstrates the synergy of direct ink writing and RF electronics for wireless applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
ECG changes in factory workers exposed to 27.2 MHz radiofrequency radiation.
Chen, Qingsong; Xu, Guoyong; Lang, Li; Yang, Aichu; Li, Shilin; Yang, Liwen; Li, Chaolin; Huang, Hanlin; Li, Tao
2013-05-01
To research the effect of 27.2 MHz radiofrequency radiation on electrocardiograms (ECG), 225 female workers operating radiofrequency machines at a shoe factory were chosen as the exposure group and 100 female workers without exposure from the same factory were selected as the control group. The 6 min electric field strength that the female workers were exposed to was 64.0 ± 25.2 V/m (mean ± SD), which exceeded 61 V/m, the International Commission on Non-Ionizing Radiation Protection reference root mean square levels for occupational exposure. A statistical difference was observed between the exposed group and the control group in terms of the rate of sinus bradycardia (χ(2) = 11.48, P = 0.003). When several known risk factors for cardiovascular disease were considered, including smoking, age, alcohol ingestion habit, and so on, the exposure duration was not an effective factor for ECG changes, sinus arrhythmia, or sinus bradycardia according to α = 0.05, while P = 0.052 for sinus arrhythmia was very close to 0.05. We did not find any statistical difference in heart rate, duration of the QRS wave (ventricular depolarization), or corrected QT intervals (between the start of the Q wave and end of the T wave) between the exposed and control groups. Occupational exposure to radiofrequency radiation was not found to be a cause of ECG changes after consideration of the confounding factors. Copyright © 2012 Wiley Periodicals, Inc.
Li, Shufeng; Li, Hongli; Mingyan, E; Yu, Bo
2009-02-01
The development of pulmonary vein stenosis has recently been described after radiofrequency ablation (RF) to treat atrial fibrillation (AF). The purpose of this study was to examine expression of TGFbeta1 in pulmonary vein stenosis after radiofrequency ablation in chronic atrial fibrillation of dogs. About 28 mongrel dogs were randomly assigned to the sham-operated group (n = 7), the AF group (n = 7), AF + RF group (n = 7), and RF group (n = 7). In AF or AF + RF groups, dogs underwent chronic pulmonary vein (PV) pacing to induce sustained AF. RF application was applied around the PVs until electrical activity was eliminated. Histological assessment of pulmonary veins was performed using hematoxylin and eosin staining; TGFbeta1 gene expression in pulmonary veins was examined by RT-PCR analysis; expression of TGFbeta1 protein in pulmonary veins was assessed by Western blot analysis. Rapid pacing from the left superior pulmonary vein (LSPV) induced sustained AF in AF group and AF + RF group. Pulmonary vein ablation terminated the chronic atrial fibrillation in dogs. Histological examination revealed necrotic tissues in various stages of collagen replacement, intimal thickening, and cartilaginous metaplasia with chondroblasts and chondroclasts. Compared with sham-operated and AF group, TGFbeta1 gene and protein expressions was increased in AF + RF or RF groups. It was concluded that TGFbeta1 might be associated with pulmonary vein stenosis after radiofrequency ablation in chronic atrial fibrillation of dogs.
Characteristics of Radio-Frequency Circuits Utilizing Ferroelectric Capacitors
NASA Technical Reports Server (NTRS)
Eskridge, Michael; Gui, Xiao; MacLeod, Todd; Ho, Fat D.
2011-01-01
Ferroelectric capacitors, most commonly used in memory circuits and variable components, were studied in simple analog radio-frequency circuits such as the RLC resonator and Colpitts oscillator. The goal was to characterize the RF circuits in terms of frequency of oscillation, gain, etc, using ferroelectric capacitors. Frequencies of oscillation of both circuits were measured and studied a more accurate resonant frequency can be obtained using the ferroelectric capacitors. Many experiments were conducted and data collected. A model to simulate the experimental results will be developed. Discrepancies in gain and frequency in these RF circuits when conventional capacitors are replaced with ferroelectric ones were studied. These results will enable circuit designers to anticipate the effects of using ferroelectric components in their radio- frequency applications.
Spectral and spatial characterisation of laser-driven positron beams
Sarri, G.; Warwick, J.; Schumaker, W.; ...
2016-10-18
The generation of high-quality relativistic positron beams is a central area of research in experimental physics, due to their potential relevance in a wide range of scientific and engineering areas, ranging from fundamental science to practical applications. There is now growing interest in developing hybrid machines that will combine plasma-based acceleration techniques with more conventional radio-frequency accelerators, in order to minimise the size and cost of these machines. Here we report on recent experiments on laser-driven generation of high-quality positron beams using a relatively low energy and potentially table-top laser system. Lastly, the results obtained indicate that current technology allowsmore » to create, in a compact setup, positron beams suitable for injection in radio-frequency accelerators.« less
Radiofrequency fields in MAS solid state NMR probes.
Tošner, Zdeněk; Purea, Armin; Struppe, Jochem O; Wegner, Sebastian; Engelke, Frank; Glaser, Steffen J; Reif, Bernd
2017-11-01
We present a detailed analysis of the radiofrequency (RF) field over full volume of a rotor that is generated in a solenoid coil. On top of the usually considered static distribution of amplitudes along the coil axis we describe dynamic radial RF inhomogeneities induced by sample rotation. During magic angle spinning (MAS), the mechanical rotation of the sample about the magic angle, a spin packet travels through areas of different RF fields and experiences periodical modulations of both the RF amplitude and the phase. These modulations become particularly severe at the end regions of the coil where the relative RF amplitude varies up to ±25% and the RF phase changes within ±30°. Using extensive numerical simulations we demonstrate effects of RF inhomogeneity on pulse calibration and for the ramped CP experiment performed at a wide range of MAS rates. In addition, we review various methods to map RF fields using a B 0 gradient along the sample (rotor axis) for imaging purposes. Under such a gradient, a nutation experiment provides directly the RF amplitude distribution, a cross polarization experiment images the correlation of the RF fields on the two channels according to the Hartmann-Hahn matching condition, while a spin-lock experiment allows to calibrate the RF amplitude employing the rotary resonance recoupling condition. Knowledge of the RF field distribution in a coil provides key to understand its effects on performance of a pulse sequence at the spectrometer and enables to set robustness requirements in the experimental design. Copyright © 2017 Elsevier Inc. All rights reserved.
Buckus, Raimondas; Strukčinskienė, Birute; Raistenskis, Juozas; Stukas, Rimantas; Šidlauskienė, Aurelija; Čerkauskienė, Rimantė; Isopescu, Dorina Nicolina; Stabryla, Jan; Cretescu, Igor
2017-01-01
During the last two decades, the number of macrocell mobile telephony base station antennas emitting radiofrequency (RF) electromagnetic radiation (EMR) in residential areas has increased significantly, and therefore much more attention is being paid to RF EMR and its effects on human health. Scientific field measurements of public exposure to RF EMR (specifically to radio frequency radiation) from macrocell mobile telephony base station antennas and RF electromagnetic field (EMF) intensity parameters in the environment are discussed in this article. The research methodology is applied according to the requirements of safety norms and Lithuanian Standards in English (LST EN). The article presents and analyses RF EMFs generated by mobile telephony base station antennas in areas accessible to the general public. Measurements of the RF electric field strength and RF EMF power density were conducted in the near- and far-fields of the mobile telephony base station antenna. Broadband and frequency-selective measurements were performed outside (on the roof and on the ground) and in a residential area. The tests performed on the roof in front of the mobile telephony base station antennas in the near-field revealed the presence of a dynamic energy interaction within the antenna electric field, which changes rapidly with distance. The RF EMF power density values on the ground at distances of 50, 100, 200, 300, 400, and 500 m from the base station are very low and are scattered within intervals of 0.002 to 0.05 μW/cm2. The results were compared with international exposure guidelines (ICNIRP). PMID:28257069
Buckus, Raimondas; Strukčinskienė, Birute; Raistenskis, Juozas; Stukas, Rimantas; Šidlauskienė, Aurelija; Čerkauskienė, Rimantė; Isopescu, Dorina Nicolina; Stabryla, Jan; Cretescu, Igor
2017-03-01
During the last two decades, the number of macrocell mobile telephony base station antennas emitting radiofrequency (RF) electromagnetic radiation (EMR) in residential areas has increased significantly, and therefore much more attention is being paid to RF EMR and its effects on human health. Scientific field measurements of public exposure to RF EMR (specifically to radio frequency radiation) from macrocell mobile telephony base station antennas and RF electromagnetic field (EMF) intensity parameters in the environment are discussed in this article. The research methodology is applied according to the requirements of safety norms and Lithuanian Standards in English (LST EN). The article presents and analyses RF EMFs generated by mobile telephony base station antennas in areas accessible to the general public. Measurements of the RF electric field strength and RF EMF power density were conducted in the near- and far-fields of the mobile telephony base station antenna. Broadband and frequency-selective measurements were performed outside (on the roof and on the ground) and in a residential area. The tests performed on the roof in front of the mobile telephony base station antennas in the near-field revealed the presence of a dynamic energy interaction within the antenna electric field, which changes rapidly with distance. The RF EMF power density values on the ground at distances of 50, 100, 200, 300, 400, and 500 m from the base station are very low and are scattered within intervals of 0.002 to 0.05 μW/cm². The results were compared with international exposure guidelines (ICNIRP).
Vijayalaxmi; Scarfi, Maria R.
2014-01-01
The escalated use of various wireless communication devices, which emit non-ionizing radiofrequency (RF) fields, have raised concerns among the general public regarding the potential adverse effects on human health. During the last six decades, researchers have used different parameters to investigate the effects of in vitro and in vivo exposures of animals and humans or their cells to RF fields. Data reported in peer-reviewed scientific publications were contradictory: some indicated effects while others did not. International organizations have considered all of these data as well as the observations reported in human epidemiological investigations to set-up the guidelines or standards (based on the quality of published studies and the “weight of scientific evidence” approach) for RF exposures in occupationally exposed individuals and the general public. Scientists with relevant expertise in various countries have also considered the published data to provide the required scientific information for policy-makers to develop and disseminate authoritative health information to the general public regarding RF exposures. This paper is a compilation of the conclusions, on the biological effects of RF exposures, from various national and international expert groups, based on their analyses. In general, the expert groups suggested a reduction in exposure levels, precautionary approach, and further research. PMID:25211777
Hartmann-Hahn 2D-map to optimize the RAMP-CPMAS NMR experiment for pharmaceutical materials.
Suzuki, Kazuko; Martineau, Charlotte; Fink, Gerhard; Steuernagel, Stefan; Taulelle, Francis
2012-02-01
Cross polarization-magic angle spinning (CPMAS) is the most used experiment for solid-state NMR measurements in the pharmaceutical industry, with the well-known variant RAMP-CPMAS its dominant implementation. The experimental work presented in this contribution focuses on the entangled effects of the main parameters of such an experiment. The shape of the RAMP-CP pulse has been considered as well as the contact time duration, and a particular attention also has been devoted to the radio-frequency (RF) field inhomogeneity. (13)C CPMAS NMR spectra have been recorded with a systematic variation of (13)C and (1)H constant radiofrequency field pair values and represented as a Hartmann-Hahn matching two-dimensional map. Such a map yields a rational overview of the intricate optimal conditions necessary to achieve an efficient CP magnetization transfer. The map also highlights the effects of sweeping the RF by the RAMP-CP pulse on the number of Hartmann-Hahn matches crossed and how RF field inhomogeneity helps in increasing the CP efficiency by using a larger fraction of the sample. In the light of the results, strategies for optimal RAMP-CPMAS measurements are suggested, which lead to a much higher efficiency than constant amplitude CP experiment. Copyright © 2012 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Takahashi, Kazunori; Nakano, Yudai; Ando, Akira
2017-07-01
A radiofrequency (rf) inductively-coupled plasma source is operated with a frequency-tuning impedance matching system, where the rf frequency is variable in the range of 20-50 MHz and the maximum power is 100 W. The source consists of a 45 mm-diameter pyrex glass tube wound by an rf antenna and a solenoid providing a magnetic field strength in the range of 0-200 Gauss. A reflected rf power for no plasma case is minimized at the frequency of ˜25 MHz, whereas the frequency giving the minimum reflection with the high density plasma is about 28 MHz, where the density jump is observed when minimizing the reflection. A high density argon plasma above 1× {{10}12} cm-3 is successfully obtained in the source for the rf power of 50-100 W, where it is observed that an external magnetic field of a few tens of Gauss yields the highest plasma density in the present configuration. The frequency-tuning plasma source is applied to a compact and high-speed silicon etcher in an Ar-SF6 plasma; then the etching rate of 8~μ m min-1 is obtained for no bias voltage to the silicon wafer, i.e. for the case that a physical ion etching process is eliminated.
Light modulated electron beam driven radiofrequency emitter
Wilson, M.T.; Tallerico, P.J.
1979-10-10
The disclosure relates to a light modulated electron beam-driven radiofrequency emitter. Pulses of light impinge on a photoemissive device which generates an electron beam having the pulse characteristics of the light. The electron beam is accelerated through a radiofrequency resonator which produces radiofrequency emission in accordance with the electron, hence, the light pulses.
Radiofrequency for the Treatment of Lumbar Radicular Pain: Impact on Surgical Indications.
Trinidad, José Manuel; Carnota, Ana Isabel; Failde, Inmaculada; Torres, Luis Miguel
2015-01-01
Study Design. Quasiexperimental study. Objective. To investigate whether radiofrequency treatment can preclude the need for spinal surgery in both the short term and long term. Background. Radiofrequency is commonly used to treat lumbosacral radicular pain. Only few studies have evaluated its effects on surgical indications. Methods. We conducted a quasiexperimental study of 43 patients who had been scheduled for spinal surgery. Radiofrequency was indicated for 25 patients. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment (pulsed radiofrequency of dorsal root ganglion, 76%; conventional radiofrequency of the medial branch, 12%; combined technique, 12%). The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment. In addition, we also evaluated adverse effects, ODI, NRS. Results. We observed after treatment with radiofrequency 80% of patients rejected spinal surgery in the short term and 76% in the long term. We conclude that radiofrequency is a useful treatment strategy that can achieve very similar outcomes to spinal surgery. Patients also reported a very high level of satisfaction (84% satisfied/very satisfied). We also found that optimization of the electrical parameters of the radiofrequency improved the outcome of this technique.
NASA Astrophysics Data System (ADS)
Lee, Hannah J.; Kadbi, Mo; Bosco, Gary; Ibbott, Geoffrey S.
2018-02-01
The integration of magnetic resonance imaging (MRI) with linear accelerators (linac) has enabled the use of 3D MR-visible gel dosimeters for real-time verification of volumetric dose distributions. Several iron-based radiochromic 3D gels were created in-house then imaged and irradiated in a pre-clinical 1.5 T-7 MV MR-Linac. MR images were acquired using a range of balanced-fast field echo (b-FFE) sequences during irradiation to assess the contrast and dose response in irradiated regions and to minimize the presence of MR artifacts. Out of four radiochromic 3D gel formulations, the FOX 3D gel was found to provide superior MR contrast in the irradiated regions. The FOX gels responded linearly with respect to real-time dose and the signal remained stable post-irradiation for at least 20 min. The response of the FOX gel also was found to be unaffected by the radiofrequency and gradient fields created by the b-FFE sequence during irradiation. A reusable version of the FOX gel was used for b-FFE sequence optimization to reduce artifacts by increasing the number of averages at the expense of temporal resolution. Regardless of the real-time MR sequence used, the FOX 3D gels responded linearly to dose with minimal magnetic field effects due to the strong 1.5 T field or gradient fields present during imaging. These gels can easily be made in-house using non-reusable and reusable formulations depending on the needs of the clinic, and the results of this study encourage further applications of 3D gels for MR-IGRT applications.
Radiofrequency ablation of hepatocellular carcinoma: Mono or multipolar?
Cartier, Victoire; Boursier, Jérôme; Lebigot, Jérôme; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Aubé, Christophe
2016-03-01
Thermo-ablation by radiofrequency is recognized as a curative treatment for early-stage hepatocellular carcinoma. However, local recurrence may occur because of incomplete peripheral tumor destruction. Multipolar radiofrequency has been developed to increase the size of the maximal ablation zone. We aimed to compare the efficacy of monopolar and multipolar radiofrequency for the treatment of hepatocellular carcinoma and determine factors predicting failure. A total of 171 consecutive patients with 214 hepatocellular carcinomas were retrospectively included. One hundred fifty-eight tumors were treated with an expandable monopolar electrode and 56 with a multipolar technique using several linear bipolar electrodes. Imaging studies at 6 weeks after treatment, then every 3 months, assessed local effectiveness. Radiofrequency failure was defined as persistent residual tumor after two sessions (primary radiofrequency failure) or local tumor recurrence during follow-up. This study received institutional review board approval (number 2014/77). Imaging showed complete tumor ablation in 207 of 214 lesions after the first session of radiofrequency. After a second session, only two cases of residual viable tumor were observed. During follow-up, there were 46 local tumor recurrences. Thus, radiofrequency failure occurred in 48/214 (22.4%) cases. By multivariate analysis, technique (P < 0.001) and tumor size (P = 0.023) were independent predictors of radiofrequency failure. Failure rate was lower with the multipolar technique for tumors < 25 mm (P = 0.023) and for tumors between 25 and 45 mm (P = 0.082). There was no difference for tumors ≥ 45 mm (P = 0.552). Compared to monopolar radiofrequency, multipolar radiofrequency improves tumor ablation with a subsequent lower rate of local tumor recurrence. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Rivera, Santiago; Ricapito, Maria de la Paz; Tomas, Leandro; Parodi, Josefina; Bardera Molina, Guillermo; Banega, Rodrigo; Bueti, Pablo; Orosco, Agustin; Reinoso, Marcelo; Caro, Milagros; Belardi, Diego; Albina, Gaston; Giniger, Alberto; Scazzuso, Fernando
2016-04-01
Catheter radiofrequency ablation of ventricular arrhythmias (VAs) arising from the left ventricle's papillary muscles has been associated with inconsistent results. The use of cryoenergy versus radiofrequency has not been compared yet. This study compares outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either cryoenergy or radiofrequency. Twenty-one patients (40±12 years old; 47% males; median ejection fraction 59±7.3%) with drug refractory premature ventricular contractions or ventricular tachycardia underwent catheter cryoablation or radiofrequency ablation. VAs were localized using 3-dimensional mapping, multidetector computed tomography, and intracardiac echocardiography, with arrhythmia foci being mapped at either the anterolateral papillary muscle or posteromedial papillary muscles of the left ventricle. Focal ablation was performed using an 8-mm cryoablation catheter or a 4-mm open-irrigated radiofrequency catheter, via transmitral approach. Acute success rate was 100% for cryoenergy (n=12) and 78% for radiofrequency (n=9; P=0.08). Catheter stability was achieved in all patients (100%) treated with cryoenergy, and only in 2 (25%) patients treated with radiofrequency (P=0.001). Incidence of multiple VA morphologies was observed in 7 patients treated with radiofrequency (77.7%), whereas none was observed in those treated with cryoenergy (P=0.001). VA recurrence at 6 months follow-up was 0% for cryoablation and 44% for radiofrequency (P=0.03). Cryoablation was associated with higher success rates and lower recurrence rates than radiofrequency catheter ablation, better catheter stability, and lesser incidence of polymorphic arrhythmias. © 2016 American Heart Association, Inc.
Usmani, Hammad; Dureja, G P; Andleeb, Roshan; Tauheed, Nazia; Asif, Naiyer
2018-01-10
Chronic nononcological perineal pain has been effectively managed by ganglion Impar block. Chemical neurolysis, cryoablation, and radiofrequency ablation have been the accepted methods of blockade. Recently, pulsed radiofrequency, a novel variant of conventional radiofrequency, has been used for this purpose. This was a prospective, randomized, double-blind study. Two different interventional pain management centers in India. To compare the efficacy of conventional radiofrequency and pulsed radiofrequency for gangliom Impar block. The patients were randomly allocated to one of two groups. In the conventional radiofrequency (CRF) group (N = 34), conventional radiofrequency ablation was done, and in the PRF pulsed radiofrequency (PRF) group (N = 31), pulsed radiofrequency ablation was done. After informed and written consent, fluoroscopy-guided ganglion Impar block was performed through the first intracoccygeal approach. The extent of pain relief was assessed by visual analog scale (VAS) at 24 hours, and at the first, third, and sixth weeks following the intervention. A questionnaire to evaluate subjective patient satisfaction was also used at each follow-up visit. In the CRF group, the mean VAS score decreased significantly from the baseline value at each follow-up visit. But in the PRF group, this decrease was insignificant except at 24-hour follow-up. Intergroup comparison also showed significantly better pain relief in the CRF group as compared with the PRF group. At the end of follow-up, 28 patients (82%) in the CRF group and four patients (13%) in the PRF group had excellent results, as assessed by the subjective patient satisfaction questionnaire. There was no complication in any patient of either study group, except for short-lived infection at the site of skin puncture in a few. Ganglion Impar block by conventional radiofrequency provided a significantly better quality of pain relief with no major side effects in patients with chronic nononcological perineal pain as compared with pulsed radiofrequency. The short-term follow-up period of only six weeks was a major drawback associated with this study. © 2018 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
USE OF RFID TO TRACK HAZARDOUS WASTE SHIPMENTS ACROSS DOMESTIC AND INTERNATIONAL BORDERS
Radio-frequency identification system (RFID) is an emerging commodity tracking technology that is being tested and implemented in a large number of applications worldwide. RFID is a method of transmitting data using radio waves, usually through communication with a tag. Both ac...
47 CFR 2.807 - Statutory exceptions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL RULES AND REGULATIONS Marketing of Radio-frequency Devices § 2.807 Statutory exceptions. As provided by Section 302(c) of the Communications Act of 1934, as amended, § 2.803 shall not be applicable to: (a...
Assembling a ring-shaped crystal in a microfabricated surface ion trap
Stick, Daniel Lynn; Tabakov, Boyan; Benito, Francisco; ...
2015-09-01
We report on experiments with a microfabricated surface trap designed for confining a chain of ions in a ring. Uniform ion separation over most of the ring is achieved with a rotationally symmetric design and by measuring and suppressing undesired electric fields. After reducing stray fields, the ions are confined primarily by a radio-frequency pseudopotential and their mutual Coulomb repulsion. As a result, approximately 400 40Ca + ions with an average separation of 9 μm comprise the ion crystal.
Assembling a ring-shaped crystal in a microfabricated surface ion trap
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stick, Daniel Lynn; Tabakov, Boyan; Benito, Francisco
We report on experiments with a microfabricated surface trap designed for confining a chain of ions in a ring. Uniform ion separation over most of the ring is achieved with a rotationally symmetric design and by measuring and suppressing undesired electric fields. After reducing stray fields, the ions are confined primarily by a radio-frequency pseudopotential and their mutual Coulomb repulsion. As a result, approximately 400 40Ca + ions with an average separation of 9 μm comprise the ion crystal.
Tunneling Statistics for Analysis of Spin-Readout Fidelity
NASA Astrophysics Data System (ADS)
Gorman, S. K.; He, Y.; House, M. G.; Keizer, J. G.; Keith, D.; Fricke, L.; Hile, S. J.; Broome, M. A.; Simmons, M. Y.
2017-09-01
We investigate spin and charge dynamics of a quantum dot of phosphorus atoms coupled to a radio-frequency single-electron transistor (SET) using full counting statistics. We show how the magnetic field plays a role in determining the bunching or antibunching tunneling statistics of the donor dot and SET system. Using the counting statistics, we show how to determine the lowest magnetic field where spin readout is possible. We then show how such a measurement can be used to investigate and optimize single-electron spin-readout fidelity.
Gene and protein expression following exposure to radiofrequency fields from mobile phones.
Vanderstraeten, Jacques; Verschaeve, Luc
2008-09-01
Since 1999, several articles have been published on genome-wide and/or proteome-wide response after exposure to radiofrequency (RF) fields whose signal and intensities were similar to or typical of those of currently used mobile telephones. These studies were performed using powerful high-throughput screening techniques (HTSTs) of transcriptomics and/or proteomics, which allow for the simultaneous screening of the expression of thousands of genes or proteins. We reviewed these HTST-based studies and compared the results with currently accepted concepts about the effects of RF fields on gene expression. In this article we also discuss these last in light of the recent concept of microwave-assisted chemistry. To date, the results of HTST-based studies of transcriptomics and/or proteomics after exposure to RF fields relevant to human exposure are still inconclusive, as most of the positive reports are flawed by methodologic imperfections or shortcomings. In addition, when positive findings were reported, no precise response pattern could be identified in a reproducible way. In particular, results from HTST studies tend to exclude the role of a cell stressor for exposure to RF fields at nonthermal intensities. However, on the basis of lessons from microwave-assisted chemistry, we can assume that RF fields might affect heat-sensitive gene or protein expression to an extent larger than would be predicted from temperature change only. But in all likelihood, this would concern intensities higher than those relevant to usual human exposure. The precise role of transcriptomics and proteomics in the screening of bioeffects from exposure to RF fields from mobile phones is still uncertain in view of the lack of positively identified phenotypic change and the lack of theoretical, as well as experimental, arguments for specific gene and/or protein response patterns after this kind of exposure.
Advanced capability RFID system
Gilbert, Ronald W.; Steele, Kerry D.; Anderson, Gordon A.
2007-09-25
A radio-frequency transponder device having an antenna circuit configured to receive radio-frequency signals and to return modulated radio-frequency signals via continuous wave backscatter, a modulation circuit coupled to the antenna circuit for generating the modulated radio-frequency signals, and a microprocessor coupled to the antenna circuit and the modulation circuit and configured to receive and extract operating power from the received radio-frequency signals and to monitor inputs on at least one input pin and to generate responsive signals to the modulation circuit for modulating the radio-frequency signals. The microprocessor can be configured to generate output signals on output pins to associated devices for controlling the operation thereof. Electrical energy can be extracted and stored in an optional electrical power storage device.
Multipolar hepatic radiofrequency ablation using up to six applicators: preliminary results.
Bruners, P; Schmitz-Rode, T; Günther, R W; Mahnken, A
2008-03-01
To evaluate the clinical feasibility and safety of hepatic radiofrequency (RF) ablation using a multipolar RF system permitting the simultaneous use of up to six electrodes. Ten patients (3 female, 7 male, mean age 61) suffering from 29 hepatic metastases (range: 1 - 5) of different tumors were treated with a modified multipolar RF system (CelonLab Power, Celon Medical Instruments, Teltow, Germany) operating four to six needle-shaped internally cooled RF applicators. The procedure duration, applied energy and generator output were recorded during the intervention. The treatment result and procedure-related complications were analyzed. The achieved coagulation volume was calculated on the basis of contrast-enhanced CT scans 24 hours after RF ablation. Complete tumor ablation was achieved in all cases as determined by the post-interventional lack of contrast enhancement in the target region using four applicators in five patients, five applicators in one patient and six applicators in four patients. A mean energy deposition of 353.9 +/- 176.2 kJ resulted in a mean coagulation volume of 115.9 +/- 79.5 cm (3). The mean procedure duration was 74.9 +/- 21.2 minutes. Four patients showed an intraabdominal hemorrhage which necessitated further interventional treatment (embolization; percutaneous histoacryl injection) in two patients. Multipolar RF ablation of hepatic metastasis with up to six applicators was clinically feasible. In our patient population it was associated with an increased risk of intraabdominal bleeding probably due to the multiple punctures associated with the use of multiple applicators.
Huber, Michaela; Loibl, Markus; Eder, Christoph; Kujat, Richard; Nerlich, Michael; Gehmert, Sebastian
2016-11-01
This cadaver study investigated the temperature profile in the wrist joint and distal radioulnar joint (DRUJ) during radiofrequency energy (RFE) application for triangular fibrocartilage complex resection. An arthroscopic partial resection of the triangular fibrocartilage complex using monopolar and bipolar RFE was simulated in 14 cadaver limbs. The temperature was recorded simultaneously in the DRUJ and at 6 other anatomic locations of the wrist during RFE application. The mean temperature in the DRUJ was 43.3 ± 8.2°C for the bipolar system in the ablation mode (60 W) and 30.4 ± 3.4°C for the monopolar system in the cut mode (20 W) after 30 seconds. The highest measured temperature in the DRUJ was 54.3°C for the bipolar system and 68.1°C for the monopolar system. The application of RFE for debridement or resection of the triangular fibrocartilage complex in a clinical setting can induce peak temperatures that might cause damage to the cartilage of the DRUJ. Bipolar systems produce higher mean temperatures than monopolar devices. RFE application increases the mean temperature in the DRUJ after 30 seconds to a level that may jeopardize cartilage tissue. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lee, Hsiang-Chieh; Ahsen, Osman O.; Liu, Jonathan J.; Tsai, Tsung-Han; Huang, Qin; Mashimo, Hiroshi; Fujimoto, James G.
2017-07-01
Radiofrequency ablation (RFA) is widely used for the eradication of dysplasia and the treatment of early stage esophageal carcinoma in patients with Barrett's esophagus (BE). However, there are several factors, such as variation of BE epithelium (EP) thickness among individual patients and varying RFA catheter-tissue contact, which may compromise RFA efficacy. We used a high-speed optical coherence tomography (OCT) system to identify and monitor changes in the esophageal tissue architecture from RFA. Two different OCT imaging/RFA application protocols were performed using an ex vivo swine esophagus model: (1) post-RFA volumetric OCT imaging for quantitative analysis of the coagulum formation using RFA applications with different energy settings, and (2) M-mode OCT imaging for monitoring the dynamics of tissue architectural changes in real time during RFA application. Post-RFA volumetric OCT measurements showed an increase in the coagulum thickness with respect to the increasing RFA energies. Using a subset of the specimens, OCT measurements of coagulum and coagulum + residual EP thickness were shown to agree with histology, which accounted for specimen shrinkage during histological processing. In addition, we demonstrated the feasibility of OCT for real-time visualization of the architectural changes during RFA application with different energy settings. Results suggest feasibility of using OCT for RFA treatment planning and guidance.
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Wheeler, D. R.
1977-01-01
Radiofrequency sputtered coatings of titanium carbide, molybdenum carbide and titanium boride were tested as wear resistant coatings on stainless steel in a pin on disk apparatus. X-ray photoelectron spectroscopy (XPS) was used to analyze the sputtered films with regard to both bulk and interface composition in order to obtain maximum film performance. Significant improvements in friction behavior were obtained when properly biased films were deposited on deliberately preoxidized substrates. XPS depth profile data showed thick graded interfaces for bias deposited films even when adherence was poor. The addition of 10 percent hydrogen to the sputtering gas produced coatings with thin poorly adherent interfaces. Results suggest that some of the common practices in the field of sputtering may be detrimental to achieving maximum adherence and optimum composition for these refractory compounds.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, W.L.; Zheng, F.; Fei, W.D.
2006-01-15
Fe-N thin films were fabricated using a direct current magnetron sputtering process assisted by a radio-frequency (rf) field. The effect of the rf field on the phase composition of the films was investigated. The results indicate that with the assistance of the rf field, various kinds of iron nitrides can be obtained in the films, including {alpha}{sup '}-Fe-N, {alpha}{sup ''}-Fe{sub 16}N{sub 2}, {xi}-Fe{sub 2}N, {epsilon}-Fe{sub 3}N, and {gamma}{sup ''}-FeN with ZnS structure. It was found that the rf field greatly benefits the formation of iron nitrides in the Fe-N films.
Performance of field-emitting resonating carbon nanotubes as radio-frequency demodulators
NASA Astrophysics Data System (ADS)
Vincent, P.; Poncharal, P.; Barois, T.; Perisanu, S.; Gouttenoire, V.; Frachon, H.; Lazarus, A.; de Langre, E.; Minoux, E.; Charles, M.; Ziaei, A.; Guillot, D.; Choueib, M.; Ayari, A.; Purcell, S. T.
2011-04-01
We report on a systematic study of the use of resonating nanotubes in a field emission (FE) configuration to demodulate radio frequency signals. We particularly concentrate on how the demodulation depends on the variation of the field amplification factor during resonance. Analytical formulas describing the demodulation are derived as functions of the system parameters. Experiments using AM and FM demodulations in a transmission electron microscope are also presented with a determination of all the pertinent experimental parameters. Finally we discuss the use of CNTs undergoing FE as nanoantennae and the different geometries that could be used for optimization and implementation.
NASA Astrophysics Data System (ADS)
Pigarev, Aleksey V.; Bazarov, Timur O.; Fedorov, Vladimir V.; Ryabushkin, Oleg A.
2018-02-01
Most modern systems of the optical image registration are based on the matrices of photosensitive semiconductor heterostructures. However, measurement of radiation intensities up to several MW/cm2 -level using such detectors is a great challenge because semiconductor elements have low optical damage threshold. Reflecting or absorbing filters that can be used for attenuation of radiation intensity, as a rule, distort beam profile. Furthermore, semiconductor based devices have relatively narrow measurement wavelength bandwidth. We introduce a novel matrix method of optical image registration. This approach doesn't require any attenuation when measuring high radiation intensities. A sensitive element is the matrix made of thin transparent piezoelectric crystals that absorb just a small part of incident optical power. Each crystal element has its own set of intrinsic (acoustic) vibration modes. These modes can be exited due to the inverse piezoelectric effect when the external electric field is applied to the crystal sample providing that the field frequency corresponds to one of the vibration mode frequencies. Such piezoelectric resonances (PR) can be observed by measuring the radiofrequency response spectrum of the crystal placed between the capacitor plates. PR frequencies strongly depend on the crystal temperature. Temperature calibration of PR frequencies is conducted in the uniform heating conditions. In the case a crystal matrix is exposed to the laser radiation the incident power can be obtained separately for each crystal element by measuring its PR frequency kinetics providing that the optical absorption coefficient is known. The operating wavelength range of such sensor is restricted by the transmission bandwidth of the applied crystals. A plane matrix constituting of LiNbO3 crystals was assembled in order to demonstrate the possibility of application of the proposed approach. The crystal elements were placed between two electrodes forming a capacitor which was interconnected to the lock-in detection system. The radiofrequency response to the applied voltage from the generator was measured simultaneously for all elements.
Dragonu, Iulius; Almujayyaz, Salam; Batzakis, Alex; Young, Liam A. J.; Purvis, Lucian A. B.; Clarke, William T.; Wichmann, Tobias; Lanz, Titus; Neubauer, Stefan; Robson, Matthew D.; Klomp, Dennis W. J.; Rodgers, Christopher T.
2017-01-01
Purpose Cardiac phosphorus magnetic resonance spectroscopy (31P-MRS) provides unique insight into the mechanisms of heart failure. Yet, clinical applications have been hindered by the restricted sensitivity of the surface radiofrequency-coils normally used. These permit the analysis of spectra only from the interventricular septum, or large volumes of myocardium, which may not be meaningful in focal disease. Löring et al. recently presented a prototype whole-body (52 cm diameter) transmit/receive birdcage coil for 31P at 7T. We now present a new, easily-removable, whole-body 31P transmit radiofrequency-coil built into a patient-bed extension combined with a 16-element receive array for cardiac 31P-MRS. Materials and methods A fully-removable (55 cm diameter) birdcage transmit coil was combined with a 16-element receive array on a Magnetom 7T scanner (Siemens, Germany). Electro-magnetic field simulations and phantom tests of the setup were performed. In vivo maps of B1+, metabolite signals, and saturation-band efficiency were acquired across the torsos of eight volunteers. Results The combined (volume-transmit, local receive array) setup increased signal-to-noise ratio 2.6-fold 10 cm below the array (depth of the interventricular septum) compared to using the birdcage coil in transceiver mode. The simulated coefficient of variation for B1+ of the whole-body coil across the heart was 46.7% (surface coil 129.0%); and the in vivo measured value was 38.4%. Metabolite images of 2,3-diphosphoglycerate clearly resolved the ventricular blood pools, and muscle tissue was visible in phosphocreatine (PCr) maps. Amplitude-modulated saturation bands achieved 71±4% suppression of phosphocreatine PCr in chest-wall muscles. Subjects reported they were comfortable. Conclusion This easy-to-assemble, volume-transmit, local receive array coil combination significantly improves the homogeneity and field-of-view for metabolic imaging of the human heart at 7T. PMID:29073228
47 CFR 80.83 - Protection from potentially hazardous RF radiation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... radiation. 80.83 Section 80.83 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND... Requirements-Ship Stations § 80.83 Protection from potentially hazardous RF radiation. Any license or renewal application for a ship earth station that will cause exposure to radiofrequency (RF) radiation in excess of...
47 CFR 80.83 - Protection from potentially hazardous RF radiation.
Code of Federal Regulations, 2013 CFR
2013-10-01
... radiation. 80.83 Section 80.83 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND... Requirements-Ship Stations § 80.83 Protection from potentially hazardous RF radiation. Any license or renewal application for a ship earth station that will cause exposure to radiofrequency (RF) radiation in excess of...
47 CFR 80.83 - Protection from potentially hazardous RF radiation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... radiation. 80.83 Section 80.83 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND... Requirements-Ship Stations § 80.83 Protection from potentially hazardous RF radiation. Any license or renewal application for a ship earth station that will cause exposure to radiofrequency (RF) radiation in excess of...
47 CFR 80.83 - Protection from potentially hazardous RF radiation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... radiation. 80.83 Section 80.83 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND... Requirements-Ship Stations § 80.83 Protection from potentially hazardous RF radiation. Any license or renewal application for a ship earth station that will cause exposure to radiofrequency (RF) radiation in excess of...
47 CFR 80.83 - Protection from potentially hazardous RF radiation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... radiation. 80.83 Section 80.83 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND... Requirements-Ship Stations § 80.83 Protection from potentially hazardous RF radiation. Any license or renewal application for a ship earth station that will cause exposure to radiofrequency (RF) radiation in excess of...
Rafati, A; Rahimi, S; Talebi, A; Soleimani, A; Haghani, M; Mortazavi, S M J
2015-09-01
The rapid growth of wireless communication technologies has caused public concerns regarding the biological effects of electromagnetic radiations on human health. Some early reports indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians such as the alterations of the pattern of muscle extractions. This study is aimed at investigating the effects of exposure to radiofrequency (RF) radiation emitted from mobile phone jammers on the pulse height of contractions, the time interval between two subsequent contractions and the latency period of frog's isolated gastrocnemius muscle after stimulation with single square pulses of 1V (1 Hz). Frogs were kept in plastic containers in a room. Animals in the jammer group were exposed to radiofrequency (RF) radiation emitted from a common Jammer at a distance of 1m from the jammer's antenna for 2 hours while the control frogs were only sham exposed. Then animals were sacrificed and isolated gastrocnemius muscles were exposed to on/off jammer radiation for 3 subsequent 10 minute intervals. Isolated gastrocnemius muscles were attached to the force transducer with a string. Using a PowerLab device (26-T), the pattern of muscular contractions was monitored after applying single square pulses of 1V (1 Hz) as stimuli. The findings of this study showed that the pulse height of muscle contractions could not be affected by the exposure to electromagnetic fields. However, the latency period was effectively altered in RF-exposed samples. However, none of the experiments could show an alteration in the time interval between two subsequent contractions after exposure to electromagnetic fields. These findings support early reports which indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians including the effects on the pattern of muscle extractions.
Wu, Wei; Wang, KaiJun; Ni, Shuang; Ye, PanPan; Yu, YiBo; Ye, Juan; Sun, LiXia
2008-01-01
Purpose The goal of this study was to investigate whether superposing of electromagnetic noise could block or attenuate DNA damage and intracellular reactive oxygen species (ROS) increase of cultured human lens epithelial cells (HLECs) induced by acute exposure to 1.8 GHz radiofrequency field (RF) of the Global System for Mobile Communications (GSM). Methods An sXc-1800 RF exposure system was used to produce a GSM signal at 1.8 GHz (217 Hz amplitude-modulated) with the specific absorption rate (SAR) of 1, 2, 3, and 4 W/kg. After 2 h of intermittent exposure, the ROS level was assessed by the fluorescent probe, 2',7'-dichlorodihydrofluorescein diacetate (DCFH-DA). DNA damage to HLECs was examined by alkaline comet assay and the phosphorylated form of histone variant H2AX (γH2AX) foci formation assay. Results After exposure to 1.8 GHz RF for 2 h, HLECs exhibited significant intracellular ROS increase in the 2, 3, and 4 W/kg groups. RF radiation at the SAR of 3 W/kg and 4 W/kg could induce significant DNA damage, examined by alkaline comet assay, which was used to detect mainly single strand breaks (SSBs), while no statistical difference in double strand breaks (DSBs), evaluated by γH2AX foci, was found between RF exposure (SAR: 3 and 4 W/kg) and sham exposure groups. When RF was superposed with 2 μT electromagnetic noise could block RF-induced ROS increase and DNA damage. Conclusions DNA damage induced by 1.8 GHz radiofrequency field for 2 h, which was mainly SSBs, may be associated with the increased ROS production. Electromagnetic noise could block RF-induced ROS formation and DNA damage. PMID:18509546
Yao, Ke; Wu, Wei; Wang, KaiJun; Ni, Shuang; Ye, PanPan; Yu, YiBo; Ye, Juan; Sun, LiXia
2008-05-19
The goal of this study was to investigate whether superposing of electromagnetic noise could block or attenuate DNA damage and intracellular reactive oxygen species (ROS) increase of cultured human lens epithelial cells (HLECs) induced by acute exposure to 1.8 GHz radiofrequency field (RF) of the Global System for Mobile Communications (GSM). An sXc-1800 RF exposure system was used to produce a GSM signal at 1.8 GHz (217 Hz amplitude-modulated) with the specific absorption rate (SAR) of 1, 2, 3, and 4 W/kg. After 2 h of intermittent exposure, the ROS level was assessed by the fluorescent probe, 2',7'-dichlorodihydrofluorescein diacetate (DCFH-DA). DNA damage to HLECs was examined by alkaline comet assay and the phosphorylated form of histone variant H2AX (gammaH2AX) foci formation assay. After exposure to 1.8 GHz RF for 2 h, HLECs exhibited significant intracellular ROS increase in the 2, 3, and 4 W/kg groups. RF radiation at the SAR of 3 W/kg and 4 W/kg could induce significant DNA damage, examined by alkaline comet assay, which was used to detect mainly single strand breaks (SSBs), while no statistical difference in double strand breaks (DSBs), evaluated by gammaH2AX foci, was found between RF exposure (SAR: 3 and 4 W/kg) and sham exposure groups. When RF was superposed with 2 muT electromagnetic noise could block RF-induced ROS increase and DNA damage. DNA damage induced by 1.8 GHz radiofrequency field for 2 h, which was mainly SSBs, may be associated with the increased ROS production. Electromagnetic noise could block RF-induced ROS formation and DNA damage.
A mechanically tunable and efficient ceramic probe for MR-microscopy at 17 Tesla
NASA Astrophysics Data System (ADS)
Kurdjumov, Sergei; Glybovski, Stanislav; Hurshkainen, Anna; Webb, Andrew; Abdeddaim, Redha; Ciobanu, Luisa; Melchakova, Irina; Belov, Pavel
2017-09-01
In this contribution we propose and study numerically a new probe (radiofrequency coil) for magnetic resonance mi-croscopy in the field of 17T. The probe is based on two coupled donut resonators made of a high-permittivity and low-loss ceramics excited by a non-resonant inductively coupled loop attached to a coaxial cable. By full-wave numerical simulation it was shown that the probe can be precisely tuned to the Larmor frequency of protons (723 MHz) by adjusting a gap between the two resonators. Moreover, the impedance of the probe can be matched by varying the distance from one of the resonators to the loop. As a result, a compact and mechanically tunable resonant probe was demonstrated for 17 Tesla applications using no lumped capacitors for tuning and matching. The new probe was numerically compared to a conventional solenoidal probe showing better efficiency.
Ultrasonography in lung pathologies: new perspectives.
Demi, Libertario; Demi, Marcello; Smargiassi, Andrea; Inchingolo, Riccardo; Faita, Francesco; Soldati, Gino
2014-01-01
Nowadays, ultrasound techniques have not gained importance in the diagnosis and monitoring of lung pathologies yet because of the high mismatch in acoustic impedance between air and intercostal tissues. However, it is evident that B-mode imaging provides important information on pulmonary tissue, although in the form of image artifacts. Notwithstanding medical evidences, there exists no ultrasound-based method dedicated to the lung, hampering de facto the full exploitation of ultrasound potentials. A chance is given by the experience acquired in other fields, where acoustic attenuation is used to estimate concentrations of suspended particles in liquids and of air-bubbles in aerated foods. Custom hardware must be developed since commercial echographic equipment has been optimized to work with low acoustic impedance mismatches, and, in general, does not provide the primitive radiofrequency (RF) signals nor the possibility to tune key acquisition parameters such as ultrasound carrier frequency and pulse bandwidth, which are surely needed for our application.
Ultrasonography in lung pathologies: new perspectives
2014-01-01
Background Nowadays, ultrasound techniques have not gained importance in the diagnosis and monitoring of lung pathologies yet because of the high mismatch in acoustic impedance between air and intercostal tissues. However, it is evident that B-mode imaging provides important information on pulmonary tissue, although in the form of image artifacts. Findings Notwithstanding medical evidences, there exists no ultrasound-based method dedicated to the lung, hampering de facto the full exploitation of ultrasound potentials. A chance is given by the experience acquired in other fields, where acoustic attenuation is used to estimate concentrations of suspended particles in liquids and of air-bubbles in aerated foods. Conclusions Custom hardware must be developed since commercial echographic equipment has been optimized to work with low acoustic impedance mismatches, and, in general, does not provide the primitive radiofrequency (RF) signals nor the possibility to tune key acquisition parameters such as ultrasound carrier frequency and pulse bandwidth, which are surely needed for our application. PMID:24834347
Savin, Adriana; Steigmann, Rozina; Bruma, Alina; Šturm, Roman
2015-01-01
This paper proposes the study and implementation of a sensor with a metamaterial (MM) lens in electromagnetic nondestructive evaluation (eNDE). Thus, the use of a new type of MM, named Conical Swiss Rolls (CSR) has been proposed. These structures can serve as electromagnetic flux concentrators in the radiofrequency range. As a direct application, plates of composite materials with carbon fibers woven as reinforcement and polyphenylene sulphide as matrix with delaminations due to low energy impacts were examined. The evaluation method is based on the appearance of evanescent modes in the space between carbon fibers when the sample is excited with a transversal magnetic along z axis (TMz) polarized electromagnetic field. The MM lens allows the transmission and intensification of evanescent waves. The characteristics of carbon fibers woven structure became visible and delaminations are clearly emphasized. The flaws can be localized with spatial resolution better than λ/2000. PMID:26151206
NASA Technical Reports Server (NTRS)
Reinhart, Richard C.; Kacpura, Thomas J.; Smith, Carl R.; Liebetreu, John; Hill, Gary; Mortensen, Dale J.; Andro, Monty; Scardelletti, Maximilian C.; Farrington, Allen
2008-01-01
This report defines a hardware architecture approach for software-defined radios to enable commonality among NASA space missions. The architecture accommodates a range of reconfigurable processing technologies including general-purpose processors, digital signal processors, field programmable gate arrays, and application-specific integrated circuits (ASICs) in addition to flexible and tunable radiofrequency front ends to satisfy varying mission requirements. The hardware architecture consists of modules, radio functions, and interfaces. The modules are a logical division of common radio functions that compose a typical communication radio. This report describes the architecture details, the module definitions, the typical functions on each module, and the module interfaces. Tradeoffs between component-based, custom architecture and a functional-based, open architecture are described. The architecture does not specify a physical implementation internally on each module, nor does the architecture mandate the standards or ratings of the hardware used to construct the radios.
Control of the conformations of ion Coulomb crystals in a Penning trap
Mavadia, Sandeep; Goodwin, Joseph F.; Stutter, Graham; Bharadia, Shailen; Crick, Daniel R.; Segal, Daniel M.; Thompson, Richard C.
2013-01-01
Laser-cooled atomic ions form ordered structures in radiofrequency ion traps and in Penning traps. Here we demonstrate in a Penning trap the creation and manipulation of a wide variety of ion Coulomb crystals formed from small numbers of ions. The configuration can be changed from a linear string, through intermediate geometries, to a planar structure. The transition from a linear string to a zigzag geometry is observed for the first time in a Penning trap. The conformations of the crystals are set by the applied trap potential and the laser parameters, and agree with simulations. These simulations indicate that the rotation frequency of a small crystal is mainly determined by the laser parameters, independent of the number of ions and the axial confinement strength. This system has potential applications for quantum simulation, quantum information processing and tests of fundamental physics models from quantum field theory to cosmology. PMID:24096901
Magnetoplasmonic RF mixing and nonlinear frequency generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Firby, C. J., E-mail: firby@ualberta.ca; Elezzabi, A. Y.
2016-07-04
We present the design of a magnetoplasmonic Mach-Zehnder interferometer (MZI) modulator facilitating radio-frequency (RF) mixing and nonlinear frequency generation. This is achieved by forming the MZI arms from long-range dielectric-loaded plasmonic waveguides containing bismuth-substituted yttrium iron garnet (Bi:YIG). The magnetization of the Bi:YIG can be driven in the nonlinear regime by RF magnetic fields produced around adjacent transmission lines. Correspondingly, the nonlinear temporal dynamics of the transverse magnetization component are mapped onto the nonreciprocal phase shift in the MZI arms, and onto the output optical intensity signal. We show that this tunable mechanism can generate harmonics, frequency splitting, and frequencymore » down-conversion with a single RF excitation, as well as RF mixing when driven by two RF signals. This magnetoplasmonic component can reduce the number of electrical sources required to generate distinct optical modulation frequencies and is anticipated to satisfy important applications in integrated optics.« less
NASA Astrophysics Data System (ADS)
Schneider, Jens; Holzer, Frank; Kraus, Markus; Kopinke, Frank-Dieter; Roland, Ulf
2016-10-01
The application of radio waves with a frequency of 13.56 MHz on electrolyte solutions in a capillary reactor led to the formation of reactive hydrogen and oxygen species and finally to molecular oxygen and hydrogen. This process of water splitting can be principally used for the elimination of hazardous chemicals in water. Two compounds, namely perfluorooctanoic acid (PFOA) and tetrahydrofuran, were converted using this process. Their main decomposition products were highly volatile and therefore transferred to a gas phase, where they could be identified by GC-MS analyses. It is remarkable that the chemical reactions could benefit from both the oxidizing and reducing species formed in the plasma process, which takes place in gas bubbles saturated with water vapor. The breaking of C-C and C-F bonds was proven in the case of PFOA, probably initiated by electron impacts and radical reactions.
Dielectric Spectroscopy of Biomolecules up to 110 GHz
NASA Astrophysics Data System (ADS)
Laux, Eva-Maria; Ermilova, Elena; Pannwitz, Daniel; Gibbons, Jessica; Hölzel, Ralph; Bier, Frank F.
2018-03-01
Radio-frequency fields in the GHz range are increasingly applied in biotechnology and medicine. In order to fully exploit both their potential and their risks detailed information about the dielectric properties of biological material is needed. For this purpose a measuring system is presented that allows the acquisition of complex dielectric spectra over 4 frequency decade up to 110 GHz. Routines for calibration and for data evaluation according to physicochemical interaction models have been developed. The frequency dependent permittivity and dielectric loss of some proteins and nucleic acids, the main classes of biomolecules, and of their sub-units have been determined. Dielectric spectra are presented for the amino acid alanine, the proteins lysozyme and haemoglobin, the nucleotides AMP and ATP, and for the plasmid pET-21, which has been produced by bacterial culture. Characterisation of a variety of biomolecules is envisaged, as is the application to studies on protein structure and function.
NASA Tech Briefs, January 2001. Volume 25, No. 1
NASA Technical Reports Server (NTRS)
2001-01-01
The topics include: 1) A "Model" of Interactive Engineering; 2) Feature Section: Communications Technology; 3) lnReview; 4) Application Briefs; 5) Submillimeter-Wave Image Sensor; 6) Ultrasonic/Sonic Drill/Corers With Integrated Sensors; 7) Normally Closed, Piezoelectrically Actuated Microvalve; 8) Magnetostrictively Actuated Valves for Cryosurgical Probes; 9) Remote Sensing of Electric Fields in Clouds; 10) Wireless-Communication Headset Subsystem To Enhance Signaling; 11) Power Amplifier With 9 to 13 dB of Gain From 65 to 146 GHz; 12) Humidity Interlock for Protecting a Cooled Laser Crystal; 13) A Lightweight Ambulatory Physiological Monitoring System; 14) Improvements in a Lightning-Measuring Instrument; 15) Broad-Band, Noninvasive Radio-Frequency Current Probe; 16) Web-Based Technology Distributes Lean Models; 17) Software Guides Aeroelastic-Systems Design; and 18) Postprocessing Software for Micromechanics Analysis Code. A Photonics West 2001 Preview Tech Brief supplement to this January 2001 issue is also included.
FPGA-based architecture for real-time data reduction of ultrasound signals.
Soto-Cajiga, J A; Pedraza-Ortega, J C; Rubio-Gonzalez, C; Bandala-Sanchez, M; Romero-Troncoso, R de J
2012-02-01
This paper describes a novel method for on-line real-time data reduction of radiofrequency (RF) ultrasound signals. The approach is based on a field programmable gate array (FPGA) system intended mainly for steel thickness measurements. Ultrasound data reduction is desirable when: (1) direct measurements performed by an operator are not accessible; (2) it is required to store a considerable amount of data; (3) the application requires measuring at very high speeds; and (4) the physical space for the embedded hardware is limited. All the aforementioned scenarios can be present in applications such as pipeline inspection where data reduction is traditionally performed on-line using pipeline inspection gauges (PIG). The method proposed in this work consists of identifying and storing in real-time only the time of occurrence (TOO) and the maximum amplitude of each echo present in a given RF ultrasound signal. The method is tested with a dedicated immersion system where a significant data reduction with an average of 96.5% is achieved. Copyright © 2011 Elsevier B.V. All rights reserved.
Comb-based radiofrequency photonic filters with rapid tunability and high selectivity
NASA Astrophysics Data System (ADS)
Supradeepa, V. R.; Long, Christopher M.; Wu, Rui; Ferdous, Fahmida; Hamidi, Ehsan; Leaird, Daniel E.; Weiner, Andrew M.
2012-03-01
Photonic technologies have received considerable attention regarding the enhancement of radiofrequency electrical systems, including high-frequency analogue signal transmission, control of phased arrays, analog-to-digital conversion and signal processing. Although the potential of radiofrequency photonics for the implementation of tunable electrical filters over broad radiofrequency bandwidths has been much discussed, the realization of programmable filters with highly selective filter lineshapes and rapid reconfigurability has faced significant challenges. A new approach for radiofrequency photonic filters based on frequency combs offers a potential route to simultaneous high stopband attenuation, fast tunability and bandwidth reconfiguration. In one configuration, tuning of the radiofrequency passband frequency is demonstrated with unprecedented (~40 ns) speed by controlling the optical delay between combs. In a second, fixed filter configuration, cascaded four-wave mixing simultaneously broadens and smoothes the comb spectra, resulting in Gaussian radiofrequency filter lineshapes exhibiting an extremely high (>60 dB) main lobe to sidelobe suppression ratio and (>70 dB) stopband attenuation.
Obajuluwa, Adejoke Olukayode; Akinyemi, Ayodele Jacob; Afolabi, Olakunle Bamikole; Adekoya, Khalid; Sanya, Joseph Olurotimi; Ishola, Azeez Olakunle
2017-01-01
Humans in modern society are exposed to an ever-increasing number of electromagnetic fields (EMFs) and some studies have demonstrated that these waves can alter brain function but the mechanism still remains unclear. Hence, this study sought to investigate the effect of 2.5 Ghz band radio-frequency electromagnetic waves (RF-EMF) exposure on cerebral cortex acetylcholinesterase (AChE) activity and their mRNA expression level as well as locomotor function and anxiety-linked behaviour in male rats. Animals were divided into four groups namely; group 1 was control (without exposure), group 2-4 were exposed to 2.5 Ghz radiofrequency waves from an installed WI-FI device for a period of 4, 6 and 8 weeks respectively. The results revealed that WiFi exposure caused a significant increase in anxiety level and affect locomotor function. Furthermore, there was a significant decrease in AChE activity with a concomitant increase in AChE mRNA expression level in WiFi exposed rats when compared with control. In conclusions, these data showed that long term exposure to WiFi may lead to adverse effects such as neurodegenerative diseases as observed by a significant alteration on AChE gene expression and some neurobehavioral parameters associated with brain damage.
Maurer, Tilman; Kuck, Karl-Heinz
2017-08-01
Atrial fibrillation is the most common cardiac arrhythmia and represents a growing clinical, social and economic challenge. Catheter ablation for symptomatic atrial fibrillation has evolved from an experimental procedure into a widespread therapy and offers a safe and effective treatment option. A prerequisite for durable PVI are transmural and contiguous circumferential lesions around the pulmonary veins. However, electrical reconnection of initially isolated pulmonary veins remains a primary concern and is a dominant factor for arrhythmia recurrence during long-term follow up. Areas covered: This article discusses the physiology of lesion formation using radiofrequency-, cryo- or laser- energy for pulmonary vein isolation and provides a detailed review of recent technological advancements in the field of radiofrequency catheters and balloon devices. Finally, future directions and upcoming developments for the interventional treatment of atrial fibrillation are discussed. Expert commentary: Durable conduction block across deployed myocardial lesions is mandatory not only for PVI but for any other cardiac ablation strategy as well. A major improvement urgently expected is the intraprocedural real-time distinction of durable lesions from interposed gaps with only transiently impaired electrical conduction. Furthermore, a simplification of ablation tools used for PVI is required to reduce the high technical complexity of the procedure.
NASA Astrophysics Data System (ADS)
Shakhmuratova, L. N.; Hutchison, W. D.; Isbister, D. J.; Chaplin, D. H.
1997-07-01
A new coherent transient in pulsed NMR, the two-pulse nutational stimulated echo, is reported for the ferromagnetic system 60CoFe using resonant perturbations on the directional emission of anisotropic γ-radiation from thermally oriented nuclei. The new spin echo is a result of non-linear nuclear spin dynamics due to large Larmor inhomogeneity active during radiofrequency pulse application. It is made readily observable through the gross detuning between NMR radiofrequency excitation and gamma radiation detection, and inhomogeneity in the Rabi frequency caused by metallic skin-effect. The method of concatenation of perturbation factors in a statistical tensor formalism is quantitatively applied to successfully predict and then fit in detail the experimental time-domain data.
Variable frequency matching to a radiofrequency source immersed in vacuum
NASA Astrophysics Data System (ADS)
Charles, C.; Boswell, R. W.; Bish, A.
2013-09-01
A low-weight (0.12 kg) low-volume fixed ceramic capacitor impedance matching system is developed for frequency agile tuning of a radiofrequency (rf) Helicon plasma thruster. Three fixed groups of capacitors are directly mounted onto a two loop rf antenna with the thruster immersed in a vacuum chamber. Optimum plasma tuning at the resonance frequency is demonstrated via measurements of the load impedance, power transfer efficiency and plasma density versus driving frequency in the 12.882-14.238 MHz range. The resonance frequency with the plasma on is higher than the resonance frequency in vacuum. The minimum rf power necessary for ignition decreases when the ignition frequency is shifted downwards from the resonance frequency. This development has direct applications in space qualification and space use of rf plasma thrusters.
Radiofrequency ablation for oral and maxillofacial pathologies: A description of the technique
NASA Astrophysics Data System (ADS)
Tandon, Rahul; Stevens, Timothy W.; Herford, Alan S.
2014-03-01
Introduction: Radiofrequency ablation (RFA) refers to a high-frequency current that heats and coagulates tissue. In the standard RFA setup, three components are used: a generator, an active electrode, and a dispersive electrode. RFA has garnered support in many of the surgical fields as an alternative to traditional procedures used in tumor removal. Other methods can prove to be more invasive and disfiguring to the patient, in addition to the unwarranted side effects; however, RFA provides a more localized treatment, resulting in decreased co-morbidity to the patient. Currently, its use in the field of oral and maxillofacial surgery is limited, as its technology has not reached our field. By describing its limited use to the optics community, we hope to expand its uses and provide patients with one more alternative treatment option. Methods and Uses: We will describe the use of RFA on three types of pathology: lymphangioma, rhabdomyoscarcoma, oral squamous cell carcinoma, and neoplastic osseous metastasis. The majority of treatments geared towards these pathologies involve surgical resection, followed by reconstruction. However, damage to vital structures coupled with esthetic disfigurement makes RFA a more valuable alternative. In many of the cases, the tumors were successfully removed without recurrence. Conclusion: While the use of RFA has been scarce in our field, we believe that with more exposure it can gain momentum as an alternative to current treatment options. However, there are improvements that we feel can be made, helping to maximize its effectiveness.
Finnie, John W; Blumbergs, Peter C; Cai, Zhao; Manavis, Jim
2009-01-01
To determine whether exposure to mobile telephone radiofrequency (RF) fields, either acutely or long-term, produces up-regulation of the water channel protein, aquaporin-4 (AQP-4). Using a purpose-designed exposure system at 900 MHz, mice were given a single, far-field whole body exposure at a specific absorption rate of 4 W/kg for 60 minutes or a similar exposure on 5 successive days/week for 104 weeks. Control mice were sham-exposed or freely mobile in a cage to control for any stress caused by restraint in the exposure module. A positive control group was given a clostridial toxin known to cause microvascular endothelial injury, severe vasogenic oedema and upregulation of AQP-4. Brains were perfusion fixed with 4% paraformaldehyde, coronal sections cut from six levels, and immunostained for the principal water channel protein in brain, AQP-4. There was no increase in AQP-4 expression in brains exposed to mobile phone microwaves compared to control (sham exposed and freely moving caged mice) brains after short or protracted exposure, while AQP-4 was substantially upregulated in the brains of mice given the clostridial toxin. Brains exposed to mobile telephone RF fields for a short (60 minutes) or long (2 years) duration did not show any immunohistochemically detectable up-regulation of the water channel protein, AQP-4, suggesting that there was no significant increase in blood-brain barrier permeability
Radiofrequency and microwave radiation in the microelectronics industry.
Cohen, R
1986-01-01
The microscopic precision required to produce minute integrated circuits is dependent on several processes utilizing radiofrequency and microwave radiation. This article provides a review of radiofrequency and microwave exposures in microelectronics and of the physical and biologic properties of these types of radiation; summarizes the existing, relevant medical literature; and provides the clinician with guidelines for diagnosis and treatment of excessive exposures to microwave and radiofrequency radiation.
Direct measurement of the lethal isotherm for radiofrequency ablation of myocardial tissue.
Wood, Mark; Goldberg, Scott; Lau, Melissa; Goel, Aneesh; Alexander, Daniel; Han, Frederick; Feinstein, Shawn
2011-06-01
The lethal isotherm for radiofrequency catheter ablation of cardiac myocardium is widely accepted to be 50°C, but this has not been directly measured. The purpose of this study was to directly measure the tissue temperature at the edge of radiofrequency lesions in real time using infrared thermal imaging. Fifteen radiofrequency lesions of 6 to 240 seconds in duration were applied to the left ventricular surface of isolated perfused pig hearts. At the end of radiofrequency delivery, a thermal image of the tissue surface was acquired with an infrared camera. The lesion was then stained and an optical image of the lesion was obtained. The thermal and optical images were electronically merged to allow determination of the tissue temperature at the edge of the lesion at the end of radiofrequency delivery. By adjusting the temperature overlay display to conform with the edge of the radiofrequency lesion, the lethal isotherm was measured to be 60.6°C (interquartile ranges, 59.7° to 62.4°C; range, 58.1° to 64.2°C). The areas encompassed by the lesion border in the optical image and the lethal isotherm in the thermal image were statistically similar and highly correlated (Spearman ρ=0.99, P<0.001). The lethal isotherm temperature was not related to the duration of radiofrequency delivery or to lesion size (both P>0.64). The areas circumscribed by 50°C isotherms were significantly larger than the areas of the lesions on optical imaging (P=0.002). By direct measurement, the lethal isotherm for cardiac myocardium is near 61°C for radiofrequency energy deliveries <240 seconds in duration. A 50°C isotherm overestimates lesion size. Accurate knowledge of the lethal isotherm for radiofrequency ablation is important to clinical practice as well as mathematical modeling of radiofrequency lesions.
Lim, Bernard; Venkatachalam, Kalpathi L; Jahangir, Arshad; Johnson, Susan B; Asirvatham, Samuel J
2008-08-01
Thromboembolism resulting from coagulum formation on the catheter and electrode surfaces is a serious complication with radiofrequency ablation procedures for heart rhythm disorders. Why coagulum occurs despite therapeutic heparinization is unclear. In this report, we demonstrate a novel approach to minimize coagulum formation based on the electromolecular characteristics of fibrinogen. Atomic force microscopy was used to establish that fibrinogen deposited on surfaces underwent conformational changes that resulted in spontaneous clot formation. We then immersed ablation catheters that were uncharged, negatively, or positively charged in heparinized blood for 30 minutes and noted the extent of clot formation. In separate experiments, ablation catheters were sutured to the ventricle of an excised porcine heart immersed in whole, heparinized blood and radiofrequency ablation performed for 5 minutes with and without charge delivered to the catheter tips. Electron microscopy of the catheter tips showed surface coverage of fibrin clot of the catheter to be 33.8% for negatively charged catheters, compared with 84.7% (P = 0.01) in noncharged catheters. There was no significant difference in surface coverage of fibrin clot between positively charged catheters (93.8%) and noncharged catheters (84.7%, P = ns). In contrast, the thickness of surface clot coverage for positively charged catheters was 87.5%, compared with 28.45% (P= 0.03) for noncharged catheters and 11.25% (P = 0.03) for negatively charged catheters, compared with noncharged catheters. We describe a novel method of placing negative charge on electrodes during ablation that reduced coagulum formation. This may decrease thromboembolism-related complications with radiofrequency ablation procedures.
Ormiston, John A; Watson, Timothy; van Pelt, Niels; Stewart, Ralph; Stewart, James T; White, Jonathon M; Doughty, Robert N; Stewart, Fiona; Macdonald, Rhona; Webster, Mark W I
2013-05-20
Renal denervation using the point-by-point application of radiofrequency energy delivered by the first-generation Symplicity system is effective in lowering office blood pressure but may be time-consuming. The OneShot Renal Denervation System with a balloon-mounted spiral electrode potentially shortens and simplifies the procedure. This study is a hypothesis-generating first-in-human study to assess feasibility, and to provide preliminary efficacy and safety data. Eligible patients had a baseline office systolic blood pressure ≥160 mmHg (or ≥150 mmHg for diabetics) and were on two or more antihypertensive medications. Nine patients were enrolled. The primary endpoint, the insertion of the OneShot balloon into each renal artery and the delivery of radiofrequency energy, was achieved in 8/9 (89%) of patients. The one failure (the first patient) was due to generator high-impedance safety shut-off threshold set too low for humans. Adverse events were minor. No patient developed renal artery stenosis. Baseline BP was 185.67 ± 18.7 mmHg and the reductions at 1, 3, 6 and 12 months were 30.1 ± 13.6 (p=0.0004), 34.2 ± 20.2 (p=0.002), 33.6 ± 32.2 (p=0.021) and 30.6 ± 22.0 (p=0.019). The OneShot renal denervation system successfully delivered radiofrequency energy to the renal arteries in a short and straightforward procedure. Australian New Zealand Clinical Trials Registry - URL: anzctr.org.au. Trial identification: ACTRN12611000987965.
Guttek, Karina; Hartig, Roland; Godenschweger, Frank; Roggenbuck, Dirk; Ricke, Jens; Reinhold, Dirk; Speck, Oliver
2015-01-01
The global use of magnetic resonance imaging (MRI) is constantly growing and the field strengths increasing. Yet, only little data about harmful biological effects caused by MRI exposure are available and published research analyzing the impact of MRI on DNA integrity reported controversial results. This in vitro study aimed to investigate the genotoxic and cytotoxic potential of 7 T ultra-high-field MRI on isolated human peripheral blood mononuclear cells. Hence, unstimulated mononuclear blood cells were exposed to 7 T static magnetic field alone or in combination with maximum permissible imaging gradients and radiofrequency pulses as well as to ionizing radiation during computed tomography and γ-ray exposure. DNA double-strand breaks were quantified by flow cytometry and automated microscopy analysis of immunofluorescence stained γH2AX. Cytotoxicity was studied by CellTiter-Blue viability assay and [3H]-thymidine proliferation assay. Exposure of unstimulated mononuclear blood cells to 7 T static magnetic field alone or combined with varying gradient magnetic fields and pulsed radiofrequency fields did not induce DNA double-strand breaks, whereas irradiation with X- and γ-rays led to a dose-dependent induction of γH2AX foci. The viability assay revealed a time- and dose-dependent decrease in metabolic activity only among samples exposed to γ-radiation. Further, there was no evidence for altered proliferation response after cells were exposed to 7 T MRI or low doses of ionizing radiation (≤ 0.2 Gy). These findings confirm the acceptance of MRI as a safe non-invasive diagnostic imaging tool, but whether MRI can induce other types of DNA lesions or DNA double-strand breaks during altered conditions still needs to be investigated. PMID:26176601
Radiofrequency ablation versus electrocautery in tonsillectomy.
Hall, Daniel J; Littlefield, Philip D; Birkmire-Peters, Deborah P; Holtel, Michael R
2004-03-01
The objective of this study was to compare the safety, difficulty of removal, and postoperative pain profile of radiofrequency ablation versus standard electrocautery removal of tonsils. A prospective, blinded study was designed to remove 1 tonsil with each of the 2 methods. Time of operation, estimated blood loss, difficulty of operation, postoperative pain, rate of postoperative hemorrhage, and the patient's preferred technique were evaluated. The operating time was significantly longer (P < 0.007) and the patients reported significantly less pain (P < 0.001) with radiofrequency ablation. There were no differences in blood loss, difficulty of operation, or postoperative hemorrhage rates. The patients preferred the radiofrequency ablation technique (P < 0.001). Radiofrequency ablation is a viable method to remove tonsillar tissue. Operating time for this procedure will likely decrease with experience. There was significantly less pain reported with radiofrequency ablation compared with standard electrocautery.
Cooled radiofrequency ablation for bilateral greater occipital neuralgia.
Vu, Tiffany; Chhatre, Akhil
2014-01-01
This report describes a case of bilateral greater occipital neuralgia treated with cooled radiofrequency ablation. The case is considered in relation to a review of greater occipital neuralgia, continuous thermal and pulsed radiofrequency ablation, and current medical literature on cooled radiofrequency ablation. In this case, a 35-year-old female with a 2.5-year history of chronic suboccipital bilateral headaches, described as constant, burning, and pulsating pain that started at the suboccipital region and radiated into her vertex. She was diagnosed with bilateral greater occipital neuralgia. She underwent cooled radiofrequency ablation of bilateral greater occipital nerves with minimal side effects and 75% pain reduction. Cooled radiofrequency ablation of the greater occipital nerve in challenging cases is an alternative to pulsed and continuous RFA to alleviate pain with less side effects and potential for long-term efficacy.
Cooled Radiofrequency Ablation for Bilateral Greater Occipital Neuralgia
Chhatre, Akhil
2014-01-01
This report describes a case of bilateral greater occipital neuralgia treated with cooled radiofrequency ablation. The case is considered in relation to a review of greater occipital neuralgia, continuous thermal and pulsed radiofrequency ablation, and current medical literature on cooled radiofrequency ablation. In this case, a 35-year-old female with a 2.5-year history of chronic suboccipital bilateral headaches, described as constant, burning, and pulsating pain that started at the suboccipital region and radiated into her vertex. She was diagnosed with bilateral greater occipital neuralgia. She underwent cooled radiofrequency ablation of bilateral greater occipital nerves with minimal side effects and 75% pain reduction. Cooled radiofrequency ablation of the greater occipital nerve in challenging cases is an alternative to pulsed and continuous RFA to alleviate pain with less side effects and potential for long-term efficacy. PMID:24716017
Ho, Kok-Yuen; Hadi, Mohamed Abdul; Pasutharnchat, Koravee; Tan, Kian-Hian
2013-01-01
Background Sacroiliac joint pain is a common cause of chronic low back pain. Different techniques for radiofrequency denervation of the sacroiliac joint have been used to treat this condition. However, results have been inconsistent because the variable sensory supply to the sacroiliac joint is difficult to disrupt completely using conventional radiofrequency. Cooled radiofrequency is a novel technique that uses internally cooled radiofrequency probes to enlarge lesion size, thereby increasing the chance of completely denervating the sacroiliac joint. The objective of this study was to evaluate the efficacy of cooled radiofrequency denervation using the SInergy™ cooled radiofrequency system for sacroiliac joint pain. Methods The charts of 20 patients with chronic sacroiliac joint pain who had undergone denervation using the SInergy™ cooled radiofrequency system were reviewed at two years following the procedure. Outcome measures included the Numeric Rating Scale for pain intensity, Patient Global Impression of Change, and Global Perceived Effect for patient satisfaction. Results Fifteen of 20 patients showed a significant reduction in pain (a decrease of at least three points on the Numeric Rating Scale). Mean Numeric Rating Scale for pain decreased from 7.4 ± 1.4 to 3.1 ± 2.5, mean Patient Global Impression of Change was “improved” (1.4 ± 1.5), and Global Perceived Effect was reported to be positive in 16 patients at two years following the procedure. Conclusion Cooled radiofrequency denervation showed long-term efficacy for up to two years in the treatment of sacroiliac joint pain. PMID:23869175
Dauphine, Christine; Reicher, Joshua J; Reicher, Murray A; Gondusky, Christina; Khalkhali, Iraj; Kim, Michelle
2015-06-01
The purpose of this study was to evaluate the safety and performance of localizing nonpalpable breast lesions using radiofrequency identification technology. Twenty consecutive women requiring preoperative localization of a breast lesion were recruited. Subjects underwent placement of both a hook wire and a radiofrequency identification tag immediately before surgery. The radiofrequency identification tag was the primary method used by the operating surgeon to localize each lesion during excision, with the hook wire serving as backup in case of tag migration or failed localization. Successful localization with removal of the intended lesion was the primary outcome measured. Tag migration and postoperative infection were also noted to assess safety. Twenty patients underwent placement of a radiofrequency identification tag, 12 under ultrasound guidance and eight with stereotactic guidance. In all cases, the radiofrequency identification tag was successfully localized by the reader at the level of the skin before incision, and the intended lesion was removed along with the radiofrequency identification tag. There were no localization failures and no postoperative infections. Tag migration did not occur before incision, but in three cases, occurred as the lesion was being retracted with fingers to make the final cut along the deep surface of the specimen. In this initial clinical study, radiofrequency tags were safe and able to successfully localize nonpalpable breast lesions. Radiofrequency identification technology may represent an alternative method to hook wire localization.
Ultra-High Accelerating Gradients in Radio-Frequency Cryogenic Copper Structures
NASA Astrophysics Data System (ADS)
Cahill, Alexander David
Normal conducting radio-frequency (rf) particle accelerators have many applications, including colliders for high energy physics, high-intensity synchrotron light sources, non-destructive testing for security, and medical radiation therapy. In these applications, the accelerating gradient is an important parameter. Specifically for high energy physics, increasing the accelerating gradient extends the potential energy reach and is viewed as a way to mitigate their considerable cost. Furthermore, a gradient increase will enable for more compact and thus accessible free electron lasers (FELs). The major factor limiting larger accelerating gradients is vacuum rf breakdown. Basic physics of this phenomenon has been extensively studied over the last few decades. During which, the occurrence of rf breakdowns was shown to be probabilistic, and can be characterized by a breakdown rate. The current consensus is that vacuum rf breakdowns are caused by movements of crystal defects induced by periodic mechanical stress. The stress may be caused by pulsed surface heating and large electric fields. A compelling piece of evidence that supports this hypothesis is that accelerating structures constructed from harder materials exhibit larger accelerating gradients for similar breakdown rates. One possible method to increase sustained electric fields in copper cavities is to cool them to temperatures below 77 K, where the rf surface resistance and coefficient of thermal expansion decrease, while the yield strength (which correlates with hardness) and thermal conductivity increase. These changes in material properties at low temperature increases metal hardness and decreases the mechanical stress from exposure to rf electromagnetic fields. To test the validity of the improvement in breakdown rate, experiments were conducted with cryogenic accelerating cavities in the Accelerator Structure Test Area (ASTA) at SLAC National Accelerator Laboratory. A short 11.4 GHz standing wave accelerating structure was conditioned to an accelerating gradient of 250 MV/m at 45 K with 108 rf pulses. At gradients greater than 150 MV/m I observed a degradation in the intrinsic quality factor of the cavity, Q0. I developed a model for the change in Q0 using measured field emission currents and rf signals. I found that the Q 0 degradation is consistent with the rf power being absorbed by strong field emission currents accelerated inside the cavity. I measured rf breakdown rates for 45 K and found 2*10-4/pulse/meter when accounting for any change in Q0. These are the largest accelerating gradients for a structure with similar breakdown rates. The final chapter presents the design of an rf photoinjector electron source that uses the cryogenic normal conducting accelerator technology: the TOPGUN. With this cryogenic rf photoinjector, the beam brightness will increase by over an order of a magnitude when compared to the current photoinjector for the Linac Coherent Light Source (LCLS). When using the TOPGUN as the source for an X-ray Free Electron Laser, the higher brightness would allow for a decrease in the required length of the LCLS undulator by more than a factor of two.
Survey of Collision Avoidance and Ranging Sensors for Mobile Robots. Revision 1
1992-12-01
diagram of the Hamamatsu’s Range-Finder Chip Set, which applies the principle of triangulation (Hamamatsu Corporation, 1990) ....................... 37...platform (Courtesy Transitions Research Company ) . ............................................ 68 37. The Sensus 300 configured for 360-degree coverage... applied to the detection of metal objects located at short-range. Typical inductive sensors generate an oscillatory radio-frequency (RF) field around a
USDA-ARS?s Scientific Manuscript database
In this chapter, definitions of dielectric properties, or permittivity, of materials and a brief discussion of the fundamental principles governing their behavior with respect to influencing factors are presented. The basic physics of the influence of frequency of the electric fields and temperatur...
Measurement and analysis of radiofrequency radiations from some mobile phone base stations in Ghana.
Amoako, J K; Fletcher, J J; Darko, E O
2009-08-01
A survey of the radiofrequency electromagnetic radiation at public access points in the vicinity of 50 cellular phone base stations has been carried out. The primary objective was to measure and analyse the electromagnetic field strength levels emitted by antennae installed and operated by the Ghana Telecommunications Company. On all the sites measurements were made using a hand-held spectrum analyser to determine the electric field level with the 900 and 1800 MHz frequency bands. The results indicated that power densities at public access points varied from as low as 0.01 microW m(-2) to as high as 10 microW m(-2) for the frequency of 900 MHz. At a transmission frequency of 1800 MHz, the variation of power densities is from 0.01 to 100 microW m(-2). The results were found to be in compliant with the International Commission on Non-ionizing Radiological Protection guidance level but were 20 times higher than the results generally obtained for such a practice elsewhere. There is therefore a need to re-assess the situation to ensure reduction in the present level as an increase in mobile phone usage is envisaged within the next few years.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herrick, R.F.; Egan-Baum, B.; Murray, W.E. Jr
1980-05-07
On June 27, 1979, NIOSH conducted a walk-through survey of the radio-frequency (RF) heat sealing area at the S.I. Jacobson Manufacturing Company, Chicago, Illinois. The purpose of the study was to identify a population of workers which could be used in a study to determine if any health effects are associated with occupational exposures to RF radiation. Electric fields produced by the RF heat sealers were measured to document exposure levels. The electric field strength levels exceeded 200 V/M (duty cycle corrected) on five of the nine heat sealers evaluated. Confounding exposures were assessed and appear not to be amore » factor. Personnel record systems were evaluated as to their suitability for use in a study of reproductive histories. It appears from the personnel records that an appropriate cohort of RF heat sealer workers and a corresponding control group cannot be identified, therefore, the S.I. Jacobson Manufacturing Company will not be included in the NIOSH study. Mention of company names or products does not constitute endorsement by the National Institute for Occupational Safety and Health.« less
Zhang, Kun; Li, Pei; He, Yaping; Bo, Xiaowan; Li, Xiaolong; Li, Dandan; Chen, Hangrong; Xu, Huixiong
2016-08-01
Despite gaining increasing attention, chelation of multiple active targeting ligands greatly increase the formation probability of protein corona, disabling active targeting. To overcome it, a synergistic retention strategy of RGD-mediated active targeting and radiofrequency (RF) electromagnetic field-enhanced permeability has been proposed here. It is validated that such a special synergistic retention strategy can promote more poly lactic-co-glycolic acid (PLGA)-based capsules encapsulating camptothecin (CPT) and solid DL-menthol (DLM) to enter and retain in tumor in vitro and in vivo upon exposure to RF irradiation, receiving an above 8 fold enhancement in HeLa retention. Moreover, the PLGA-based capsules can respond RF field to trigger the entrapped DLM to generate solid-liquid-gas (SLG) tri-phase transformation for enhancing RF ablation and CPT release. Therefore, depending on the enhanced RF ablation and released CPT and the validated synergistic retention effect, the inhibitory outcome for tumor growth has gained an over 10-fold improvement, realizing RF ablation & chemotherapy synergistic treatment against HeLa solid tumor, which indicates a significant promise in clinical RF ablation. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jauchem, J.R.; Frei, M.R.; Padilla, J.M.
1990-09-01
Ketamine-anesthetized Sprague-Dawley rats were exposed to far-field 1200-MHz continuous wave radiofrequency radiation in both E and H orientations (long axis of animal parallel to electric or magnetic field, respectively). Power densities were used that resulted in equivalent whole-body specific absorption rates of approximately 8 W/kg in both orientations (20 mW/cm{sup 2} for E and 45 mW/cm{sup 2} for H). Exposure was conducted to repeatedly increase colonic temperature from 38.5 to 39.5{degrees}C in both orientations in the same animal. Irradiation in E orientation resulted in greater colonic, tympanic, left subcutaneous (side toward antenna), and tail heating. The results indicated a moremore » uniform distribution of heat than that which occurred in previous experiments of 2450-MHz irradiation in E and H orientation. A lack of significant differences in blood pressure and heart rate responses between exposures in the two orientations in this study suggest that greater peripheral heating, as was seen in the earlier study of 2450 MHz, is necessary for these differences to occur.« less
Assessment of long-term spatio-temporal radiofrequency electromagnetic field exposure.
Aerts, Sam; Wiart, Joe; Martens, Luc; Joseph, Wout
2018-02-01
As both the environment and telecommunications networks are inherently dynamic, our exposure to environmental radiofrequency (RF) electromagnetic fields (EMF) at an arbitrary location is not at all constant in time. In this study, more than a year's worth of measurement data collected in a fixed low-cost exposimeter network distributed over an urban environment was analysed and used to build, for the first time, a full spatio-temporal surrogate model of outdoor exposure to downlink Global System for Mobile Communications (GSM) and Universal Mobile Telecommunications System (UMTS) signals. Though no global trend was discovered over the measuring period, the difference in measured exposure between two instances could reach up to 42dB (a factor 12,000 in power density). Furthermore, it was found that, taking into account the hour and day of the measurement, the accuracy of the surrogate model in the area under study was improved by up to 50% compared to models that neglect the daily temporal variability of the RF signals. However, further study is required to assess the extent to which the results obtained in the considered environment can be extrapolated to other geographic locations. Copyright © 2017 Elsevier Inc. All rights reserved.
Schüz, Joachim; Böhler, Eva; Schlehofer, Brigitte; Berg, Gabriele; Schlaefer, Klaus; Hettinger, Iris; Kunna-Grass, Katharina; Wahrendorf, Jürgen; Blettner, Maria
2006-07-01
The objective of this study was to test the hypothesis that exposure to continuous low-level radiofrequency electromagnetic fields (RF EMFs) increases the risk of glioma and meningioma. Participants in a population-based case-control study in Germany on the risk of brain tumors in relation to cellular phone use were 747 incident brain tumor cases between the ages of 30 and 69 years and 1494 matched controls. The exposure measure of this analysis was the location of a base station of a DECT (Digital Enhanced Cordless Telecommunications) cordless phone close to the bed, which was used as a proxy for continuous low-level exposure to RF EMFs during the night. Estimated odds ratios were 0.82 (95% confidence interval: 0.29-2.33) for glioma and 0.83 (0.29-2.36) for meningioma. There was also no increasing risk observed with duration of exposure to DECT cordless phone base stations. Although the study was limited due to the small number of exposed subjects, it is still a first indication that residential low-level exposure to RF EMFs may not pose a higher risk of brain tumors.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-17
...; Formerly Docket No. 2004D-0499] Compliance Policy Guide; Radiofrequency Identification Feasibility Studies... extending the expiration date of compliance policy guide (CPG) Sec. 400.210 entitled ``Radiofrequency... 74669
Synthesis and measurement of ultrafast waveforms from five discrete optical harmonics.
Chan, Han-Sung; Hsieh, Zhi-Ming; Liang, Wei-Hong; Kung, A H; Lee, Chao-Kuei; Lai, Chien-Jen; Pan, Ru-Pin; Peng, Lung-Han
2011-03-04
Achieving the control of light fields in a manner similar in sophistication to the control of electromagnetic fields in the microwave and radiofrequency regimes has been a major challenge in optical physics research. We manipulated the phase and amplitude of five discrete harmonics spanning the blue to mid-infrared frequencies to produce instantaneous optical fields in the shape of square, sawtooth, and subcycle sine and cosine pulses at a repetition rate of 125 terahertz. Furthermore, we developed an all-optical shaper-assisted linear cross-correlation technique to retrieve these fields and thereby verified their shapes and confirmed the critical role of carrier-envelope phase in Fourier synthesis of optical waveforms.
Júnior, Luiz Carlos de Caires; Guimarães, Ernesto da Silveira Goulart; Musso, Camila Manso; Stabler, Collin Turner; Garcia, Raúl Marcel González; Mourão-Júnior, Carlos Alberto; Andreazzi, Ana Eliza
2014-09-01
The development of communication systems has brought great social and economic benefits to society. As mobile phone use has become widespread, concerns have emerged regarding the potential adverse effects of radiofrequency electromagnetic radiation (RF-EMR) used by these devices. To verify potential effects of mobile phone radiation on the central nervous system (CNS) in an animal model. Male Wistar rats (60 days old) were exposed to RF-EMR from a Global System for Mobile (GSM) cell phone (1·8 GHz) for 3 days. At the end of the exposure, the following behavioral tests were performed: open field and object recognition. Our results showed that exposed animals did not present anxiety patterns or working memory impairment, but stress behavior actions were observed. Given the results of the present study, we speculate that RF-EMR does not promote CNS impairment, but suggest that it may lead to stressful behavioral patterns.
Baker-Jarvis, James; Kim, Sung
2012-01-01
The goal of this paper is to overview radio-frequency (RF) electromagnetic interactions with solid and liquid materials from the macroscale to the nanoscale. The overview is geared toward the general researcher. Because this area of research is vast, this paper concentrates on currently active research areas in the megahertz (MHz) through gigahertz (GHz) frequencies, and concentrates on dielectric response. The paper studies interaction mechanisms both from phenomenological and fundamental viewpoints. Relaxation, resonance, interface phenomena, plasmons, the concepts of permittivity and permeability, and relaxation times are summarized. Topics of current research interest, such as negative-index behavior, noise, plasmonic behavior, RF heating, nanoscale materials, wave cloaking, polaritonic surface waves, biomaterials, and other topics are overviewed. Relaxation, resonance, and related relaxation times are overviewed. The wavelength and material length scales required to define permittivity in materials is discussed. PMID:26900513