Sample records for radiofrequency guide wire

  1. Radiofrequency Guide Wire Recanalization of Venous Occlusions in Patients with Malignant Superior Vena Cava Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Robert M.; David, Elizabeth; Pugash, Robyn A.

    Fibrotic central venous occlusions in patients with thoracic malignancy and prior radiotherapy can be impassable with standard catheters and wires, including the trailing or stiff end of a hydrophilic wire. We report two patients with superior vena cava syndrome in whom we successfully utilized a radiofrequency guide wire (PowerWire, Baylis Medical, Montreal, Quebec, Canada) to perforate through the occlusion and recanalize the occluded segment to alleviate symptoms.

  2. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu; Elliott, Eric D., E-mail: eric.elliott@osumc.edu; Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  3. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ricci, Carmelo; Ceccherini, Claudio, E-mail: claudiocec@hotmail.it; Leonini, Sara

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  4. In Vivo Evaluation and Proof of Radiofrequency Safety of a Novel Diagnostic MR-Electrophysiology Catheter

    PubMed Central

    Weiss, Steffen; Wirtz, Daniel; David, Bernd; Krueger, Sascha; Lips, Oliver; Caulfield, Dennis; Pedersen, Steen Fjord; Bostock, Julian; Razavi, Reza; Schaeffter, Tobias

    2013-01-01

    An MR-electrophysiology (EP) catheter is presented that provides full diagnostic EP functionality and a high level of radiofrequency safety achieved by custom-designed transmission lines. Highly resistive wires transmit intracardiac electrograms and currents for intracardiac pacing. A transformer cable transmits the localization signal of a tip coil. Specific absorption rate simulations and temperature measurements at 1.5 T demonstrate that a wire resistance > 3 kΩ/m limits dielectric heating to a physiologically irrelevant level. Additional wires do not increase tip specific absorption rate significantly, which is important because some clinical catheters require up to 20 electrodes. It is further demonstrated that radiofrequency-induced and pacing-induced resistive heating of the wires is negligible under clinical conditions. The MR-EP catheters provided uncompromised recording of electrograms and cardiac pacing in combination with a standard EP recorder in MR-guided in vivo EP studies, and the tip coil enabled fast and robust catheter localization. In vivo temperature measurements during such a study did not detect any device-related heating, which confirms the high level of safety of the catheter, whereas unacceptable heating was found with a standard EP catheter. The presented concept for the first time enables catheters with full diagnostic EP functionality and active tracking and at the same time a sufficient level of radiofrequency safety for MRI without specific absorption rate-related limitations. PMID:21337409

  5. In vivo evaluation and proof of radiofrequency safety of a novel diagnostic MR-electrophysiology catheter.

    PubMed

    Weiss, Steffen; Wirtz, Daniel; David, Bernd; Krueger, Sascha; Lips, Oliver; Caulfield, Dennis; Pedersen, Steen Fjord; Bostock, Julian; Razavi, Reza; Schaeffter, Tobias

    2011-03-01

    An MR-electrophysiology (EP) catheter is presented that provides full diagnostic EP functionality and a high level of radiofrequency safety achieved by custom-designed transmission lines. Highly resistive wires transmit intracardiac electrograms and currents for intracardiac pacing. A transformer cable transmits the localization signal of a tip coil. Specific absorption rate simulations and temperature measurements at 1.5 T demonstrate that a wire resistance > 3 kΩ/m limits dielectric heating to a physiologically irrelevant level. Additional wires do not increase tip specific absorption rate significantly, which is important because some clinical catheters require up to 20 electrodes. It is further demonstrated that radiofrequency-induced and pacing-induced resistive heating of the wires is negligible under clinical conditions. The MR-EP catheters provided uncompromised recording of electrograms and cardiac pacing in combination with a standard EP recorder in MR-guided in vivo EP studies, and the tip coil enabled fast and robust catheter localization. In vivo temperature measurements during such a study did not detect any device-related heating, which confirms the high level of safety of the catheter, whereas unacceptable heating was found with a standard EP catheter. The presented concept for the first time enables catheters with full diagnostic EP functionality and active tracking and at the same time a sufficient level of radiofrequency safety for MRI without specific absorption rate-related limitations. Copyright © 2010 Wiley-Liss, Inc.

  6. Radiofrequency wire for the recanalization of central vein occlusions that have failed conventional endovascular techniques.

    PubMed

    Guimaraes, Marcelo; Schonholz, Claudio; Hannegan, Christopher; Anderson, Michael Bret; Shi, June; Selby, Bayne

    2012-08-01

    To report the technique and acute technical results associated with the PowerWire Radiofrequency (RF) Guidewire used to recanalize central vein occlusions (CVOs) after the failure of conventional endovascular techniques. A retrospective study was conducted from January 2008 to December 2011, which identified all patients with CVOs who underwent treatment with a novel RF guide wire. Forty-two symptomatic patients (with swollen arm or superior vena cava [SVC] syndrome) underwent RF wire recanalization of 43 CVOs, which were then implanted with stents. The distribution of CVOs in central veins was as follows: six subclavian, 29 brachiocephalic, and eight SVC. All patients had a history of central venous catheter placement. Patients were monitored with regular clinical evaluations and central venography after treatment. All 42 patients had successful recanalization of CVOs facilitated by the RF wire technique. There was one complication, which was not directly related to the RF wire: one case of cardiac tamponade attributed to balloon angioplasty after stent placement. Forty of 42 patients (95.2%) had patent stents and were asymptomatic at 6 and 9 months after treatment. The present results suggest that the RF wire technique is a safe and efficient alternative in the recanalization of symptomatic and chronic CVOs when conventional endovascular techniques have failed. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  7. Radiofrequency power deposition near metallic wires during MR imaging: feasibility study using T1-weighted thermal imaging.

    PubMed

    Oulmane, F; Detti, V; Grenier, D; Perrin, E; Saint-Jalmes, H

    2007-01-01

    The presence of metallic conductors (implants, wires or catheters) is prohibited in MR imaging for safety purpose with respect to radiofrequency (RF) power deposition caused by RF excitation B1 field. This work describes the use of T1-weigthed MR imaging for estimating a thermal map around a metallic (copper) wire located in the center of a MR imaging unit during an imaging sequence. The experimental set up and the methodology used for capturing the elevation of temperature created by radiofrequency power deposition around the wire is presented. A proof of its efficiency to followup temperature elevation about 0,5 degrees C in a milimetric region of interest (pixel size: 1 x 1 mm2, slice thickness 5 mm) located around the wire is given, leading to further developments of MR imaging in presence of metallic implants, coils or catheters.

  8. A prospective clinical study to evaluate the safety and performance of wireless localization of nonpalpable breast lesions using radiofrequency identification technology.

    PubMed

    Dauphine, Christine; Reicher, Joshua J; Reicher, Murray A; Gondusky, Christina; Khalkhali, Iraj; Kim, Michelle

    2015-06-01

    The purpose of this study was to evaluate the safety and performance of localizing nonpalpable breast lesions using radiofrequency identification technology. Twenty consecutive women requiring preoperative localization of a breast lesion were recruited. Subjects underwent placement of both a hook wire and a radiofrequency identification tag immediately before surgery. The radiofrequency identification tag was the primary method used by the operating surgeon to localize each lesion during excision, with the hook wire serving as backup in case of tag migration or failed localization. Successful localization with removal of the intended lesion was the primary outcome measured. Tag migration and postoperative infection were also noted to assess safety. Twenty patients underwent placement of a radiofrequency identification tag, 12 under ultrasound guidance and eight with stereotactic guidance. In all cases, the radiofrequency identification tag was successfully localized by the reader at the level of the skin before incision, and the intended lesion was removed along with the radiofrequency identification tag. There were no localization failures and no postoperative infections. Tag migration did not occur before incision, but in three cases, occurred as the lesion was being retracted with fingers to make the final cut along the deep surface of the specimen. In this initial clinical study, radiofrequency tags were safe and able to successfully localize nonpalpable breast lesions. Radiofrequency identification technology may represent an alternative method to hook wire localization.

  9. Offline impedance measurements for detection and mitigation of dangerous implant interactions: an RF safety prescreen.

    PubMed

    Ellenor, Christopher W; Stang, Pascal P; Etezadi-Amoli, Maryam; Pauly, John M; Scott, Greig C

    2015-03-01

    The concept of a "radiofrequency safety prescreen" is investigated, wherein dangerous interactions between radiofrequency fields used in MRI, and conductive implants in patients are detected through impedance changes in the radiofrequency coil. The behavior of coupled oscillators is reviewed, and the resulting, observable impedance changes are discussed. A birdcage coil is loaded with a static head phantom and a wire phantom with a wire close to its resonant length, the shape, position, and orientation of which can be changed. Interactions are probed with a current sensor and network analyzer. Impedance spectra show dramatic, unmistakable splitting in cases of strong coupling, and strong correlation is observed between induced current and scattering parameters. The feasibility of a new, low-power prescreening technique has been demonstrated in a simple phantom experiment, which can unambiguously detect resonant interactions between an implanted wire and an imaging coil. A new technique has also been presented which can detect parallel transmit null modes for the wire. © 2014 Wiley Periodicals, Inc.

  10. Offline Impedance Measurements for Detection and Mitigation of Dangerous Implant Interactions: An RF Safety Prescreen

    PubMed Central

    Ellenor, Christopher W; Stang, Pascal P; Etezadi-Amoli, Maryam; Pauly, John M; Scott, Greig C

    2015-01-01

    Purpose The concept of a “radiofrequency safety prescreen” is investigated, wherein dangerous interactions between radiofrequency fields used in MRI, and conductive implants in patients are detected through impedance changes in the radiofrequency coil. Theory The behavior of coupled oscillators is reviewed, and the resulting, observable impedance changes are discussed. Methods A birdcage coil is loaded with a static head phantom and a wire phantom with a wire close to its resonant length, the shape, position, and orientation of which can be changed. Interactions are probed with a current sensor and network analyzer. Results Impedance spectra show dramatic, unmistakable splitting in cases of strong coupling, and strong correlation is observed between induced current and scattering parameters. Conclusions The feasibility of a new, low-power prescreening technique has been demonstrated in a simple phantom experiment, which can unambiguously detect resonant interactions between an implanted wire and an imaging coil. A new technique has also been presented which can detect parallel transmit null modes for the wire. Magn Reson Med 73:1328–1339, 2015. © 2014 Wiley Periodicals, Inc. PMID:24623586

  11. Wire harness twisting aid

    NASA Technical Reports Server (NTRS)

    Casey, E. J.; Commadore, C. C.; Ingles, M. E.

    1980-01-01

    Long wire bundles twist into uniform spiral harnesses with help of simple apparatus. Wires pass through spacers and through hand-held tool with hole for each wire. Ends are attached to low speed bench motor. As motor turns, operator moves hand tool away forming smooth twists in wires between motor and tool. Technique produces harnesses that generate less radio-frequency interference than do irregularly twisted cables.

  12. 77 FR 74668 - Compliance Policy Guide; Radiofrequency Identification Feasibility Studies and Pilot Programs for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-17

    ...; Formerly Docket No. 2004D-0499] Compliance Policy Guide; Radiofrequency Identification Feasibility Studies... extending the expiration date of compliance policy guide (CPG) Sec. 400.210 entitled ``Radiofrequency... 74669

  13. An optically coupled system for quantitative monitoring of MRI-induced RF currents into long conductors.

    PubMed

    Zanchi, Marta G; Venook, Ross; Pauly, John M; Scott, Greig C

    2010-01-01

    The currents induced in long conductors such as guidewires by the radio-frequency (RF) field in magnetic resonance imaging (MRI) are responsible for potentially dangerous heating of surrounding media, such as tissue. This paper presents an optically coupled system with the potential to quantitatively measure the RF currents induced on these conductors. The system uses a self shielded toroid transducer and active circuitry to modulate a high speed light-emitting-diode transmitter. Plastic fiber guides the light to a photodiode receiver and transimpedance amplifier. System validation included a series of experiments with bare wires that compared wire tip heating by fluoroptic thermometers with the RF current sensor response. Validations were performed on a custom whole body 64 MHz birdcage test platform and on a 1.5 T MRI scanner. With this system, a variety of phenomena were demonstrated including cable trap current attenuation, lossy dielectric Q-spoiling and even transverse electromagnetic wave node patterns. This system should find applications in studies of MRI RF safety for interventional devices such as pacemaker leads, and guidewires. In particular, variations of this device could potentially act as a realtime safety monitor during MRI guided interventions.

  14. Ultrasound-guided greater occipital nerve blocks and pulsed radiofrequency ablation for diagnosis and treatment of occipital neuralgia.

    PubMed

    Vanderhoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-09-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves.

  15. Ultrasound-Guided Greater Occipital Nerve Blocks and Pulsed Radiofrequency Ablation for Diagnosis and Treatment of Occipital Neuralgia

    PubMed Central

    VanderHoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-01-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves. PMID:24282778

  16. Technique for CT Fluoroscopy-Guided Lumbar Medial Branch Blocks and Radiofrequency Ablation.

    PubMed

    Amrhein, Timothy J; Joshi, Anand B; Kranz, Peter G

    2016-09-01

    The purpose of this study is to describe the procedure for CT fluoroscopy-guided lumbar medial branch blocks and facet radiofrequency ablation. CT fluoroscopic guidance allows more-precise needle tip positioning and is an alternative method for performing medial branch blocks and facet radiofrequency ablation.

  17. Percutaneous direct mitral annuloplasty using the Mitralign Bident system: description of the method and a case report.

    PubMed

    Siminiak, Tomasz; Dankowski, Rafał; Baszko, Artur; Lee, Christopher; Firek, Ludwik; Kałmucki, Piotr; Szyszka, Andrzej; Groothuis, Adam

    2013-01-01

    Functional mitral regurgitation (FMR) is known to contribute to a poor prognosis in patients with heart failure (HF). Current guidelines do not recommend cardiac surgery in patients with FMR and impaired ejection fraction due to the high procedural risk. Percutaneous techniques aimed at mitral valve repair may constitute an alternative to currently used routine medical treatment. To provide a description of a novel percutaneous suture-based technique of direct mitral annuloplasty using the Mitralign Bident system, as well as report our first case successfully treated with this method. A deflectable guiding catheter is advanced via the femoral route across the aortic valve to the posterior wall of the ventricle. A nested deflectable catheter is advanced through the guide toward the mitral annulus that allows the advancement of an insulated radiofrequency wire to cross the annulus. The wire is directed across the annulus in a target area that is 2-5 mm from the base of the leaflet into the annulus, as assessed by real-time 3D transoesophageal echocardiography. After placement of the first wire, another wire is positioned using a duel lumen bident delivery catheter, which provides a predetermined separation between wires (i.e. 14, 17 or 21 mm). Each wire provides a guide rail for implantation of sutured pledget implants within the annulus. Two pairs of pledgets are implanted, one pair in each of the P1 and P3 scallop regions of the posterior mitral annulus. A dedicated plication lock device is used to provide a means for plication of the annulus within each pair of the pledgets, and to retain the plication by delivering a suture locking implant. The plications result in improved leaflet coaptation and a reduction of the regurgitant orifice area. A 60-year-old female with diagnosed dilated cardiomyopathy, concomitant FMR class III and congestive HF was successfully treated with the Mitralign Bident system. Two pairs of pledgets were implanted resulting in an improvement of transoesophageal echocardiographic parameters, including proximal isovelocity surface area radius (0.7 cm to 0.4 cm), effective regurgitant orfice area (0.3 cm² to 0.1 cm²) and mitral regurgitant volume (49 mL to 10 mL). Percutaneous mitral annuloplasty with the Mitralign Bident system is feasible. Future clinical trials are needed to assess its safety and efficacy.

  18. Wireless communication with implanted medical devices using the conductive properties of the body.

    PubMed

    Ferguson, John E; Redish, A David

    2011-07-01

    Many medical devices that are implanted in the body use wires or wireless radiofrequency telemetry to communicate with circuitry outside the body. However, the wires are a common source of surgical complications, including breakage, infection and electrical noise. In addition, radiofrequency telemetry requires large amounts of power and results in low-efficiency transmission through biological tissue. As an alternative, the conductive properties of the body can be used to enable wireless communication with implanted devices. In this article, several methods of intrabody communication are described and compared. In addition to reducing the complications that occur with current implantable medical devices, intrabody communication can enable novel types of miniature devices for research and clinical applications.

  19. Effect of orthodontic brackets and different wires on radiofrequency heating and magnetic field interactions during 3-T MRI

    PubMed Central

    Görgülü, S; Ayyıldız, S; Gökçe, S; Ozen, T

    2014-01-01

    Objectives: To evaluate the heating and magnetic field interactions of fixed orthodontic appliances with different wires and ligaments in a 3-T MRI environment and to estimate the safety of these orthodontic materials. Methods: 40 non-carious extracted human maxillary teeth were embedded in polyvinyl chloride boxes, and orthodontic brackets were bonded. Nickel–titanium and stainless steel arch wires, and elastic and stainless steel ligaments were used to obtain four experimental groups in total. Specimens were evaluated at 3 T for radiofrequency heating and magnetic field interactions. Radiofrequency heating was evaluated by placing specimens in a cylindrical plastic container filled with isotonic solution and measuring changes in temperature after T1 weighted axial sequencing and after completion of all sequences. Translational attraction and torque values of specimens were also evaluated. One-way ANOVA test was used to compare continuous variables of temperature change. Significance was set at p < 0.05. Results: None of the groups exhibited excessive heating (highest temperature change: <3.04 °C), with the maximum increase in temperature observed at the end of the T1 weighted axial sequence. Magnetic field interactions changed depending on the material used. Although the brackets presented minor interactions that would not cause movement in situ, nickel–titanium and stainless steel wires presented great interactions that may pose a risk for the patient. Conclusions: The temperature changes of the specimens were considered to be within acceptable ranges. With regard to magnetic field interactions, brackets can be considered “MR safe”; however, it would be safe to replace the wires before MRI. PMID:24257741

  20. A novel four-wire-driven robotic catheter for radio-frequency ablation treatment.

    PubMed

    Yoshimitsu, Kitaro; Kato, Takahisa; Song, Sang-Eun; Hata, Nobuhiko

    2014-09-01

       Robotic catheters have been proposed to increase the efficacy and safety of the radio-frequency ablation treatment. The robotized motion of current robotic catheters mimics the motion of manual ones-namely, deflection in one direction and rotation around the catheter. With the expectation that the higher dexterity may achieve further efficacy and safety of the robotically driven treatment, we prototyped a four-wire-driven robotic catheter with the ability to deflect in two- degree-of-freedom motions in addition to rotation.    A novel quad-directional structure with two wires was designed and developed to attain yaw and pitch motion in the robotic catheter. We performed a mechanical evaluation of the bendability and maneuverability of the robotic catheter and compared it with current manual catheters.    We found that the four-wire-driven robotic catheter can achieve a pitching angle of 184.7[Formula: see text] at a pulling distance of wire for 11 mm, while the yawing angle was 170.4[Formula: see text] at 11 mm. The robotic catheter could attain the simultaneous two- degree-of-freedom motions in a simulated cardiac chamber.    The results indicate that the four-wire-driven robotic catheter may offer physicians the opportunity to intuitively control a catheter and smoothly approach the focus position that they aim to ablate.

  1. 21 CFR 870.1330 - Catheter guide wire.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter guide wire. 870.1330 Section 870.1330...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1330 Catheter guide wire. (a) Identification. A catheter guide wire is a coiled wire that is designed to fit inside a...

  2. 21 CFR 870.1330 - Catheter guide wire.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter guide wire. 870.1330 Section 870.1330...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1330 Catheter guide wire. (a) Identification. A catheter guide wire is a coiled wire that is designed to fit inside a...

  3. Dual wire welding torch and method

    DOEpatents

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  4. Internal wire guide for GTAW welding

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E. (Inventor); Dyer, Gerald E. (Inventor)

    1989-01-01

    A welding torch for gas tungsten arc welding apparatus has a filler metal wire guide positioned within the torch, and within the shielding gas nozzle. The wire guide is adjacent to the tungsten electrode and has a ceramic liner through which the wire is fed. This reduces the size of the torch and eliminates the outside clearance problems that exit with external wire guides. Additionally, since the wire is always within the shielding gas, oxidizing of the wire is eliminated.

  5. Cost-utility analysis of great saphenous vein ablation with radiofrequency, foam and surgery in the emerging health-care setting of Thailand.

    PubMed

    Siribumrungwong, Boonying; Noorit, Pinit; Wilasrusmee, Chumpon; Leelahavarong, Pattara; Thakkinstian, Ammarin; Teerawattananon, Yot

    2016-09-01

    To conduct economic evaluations of radiofrequency ablation, ultrasound-guided foam sclerotherapy and surgery for great saphenous vein ablation. A cost-utility and cohort analysis from societal perspective was performed to estimate incremental cost-effectiveness ratio. Transitional probabilities were from meta-analysis. Direct medical, direct non-medical, indirect costs, and utility were from standard Thai costings and cohort. Probabilistic sensitivity analysis was performed to assess parameter uncertainties. Seventy-seven patients (31 radiofrequency ablation, 19 ultrasound-guided foam sclerotherapy, and 27 surgeries) were enrolled from October 2011 to February 2013. Compared with surgery, radiofrequency ablation costed 12,935 and 20,872 Baht higher, whereas ultrasound-guided foam sclerotherapy costed 6159 lower and 1558 Bath higher for outpatient and inpatient, respectively. At one year, radiofrequency ablation had slightly lower quality-adjusted life-year, whereas ultrasound-guided foam sclerotherapy yielded additional 0.025 quality-adjusted life-year gained. Because of costing lower and greater quality-adjusted life-year than other compared alternatives, outpatient ultrasound-guided foam sclerotherapy was an option being dominant. Probabilistic sensitivity analysis resulted that at the Thai ceiling threshold of 160,000 Baht/quality-adjusted life-year gained, ultrasound-guided foam sclerotherapy had chances of 0.71 to be cost-effective. Ultrasound-guided foam sclerotherapy seems to be cost-effective for treating great saphenous vein reflux compared to surgery in Thailand at one-year results. © The Author(s) 2015.

  6. Multicenter comparative trial of the V-scope system for therapeutic ERCP.

    PubMed

    Joyce, A M; Ahmad, N A; Beilstein, M C; Kochman, M L; Long, W B; Baron, T; Sherman, S; Fogel, E; Lehman, G A; McHenry, L; Watkins, J; Ginsberg, G G

    2006-07-01

    A new duodenoscope (the V-scope), with a modified elevator used in combination with a dedicated short guide wire, constitutes the V-system. This system is intended to allow fixation of the guide wire at the elevator lever, thereby enhancing the speed and reliability of accessory exchange over a guide wire during ERCP. The aim of this study was to evaluate the extent to which the V-system provides improved efficiency in comparison with conventional duodenoscope and guide wire combinations. This was an industry-sponsored multicenter randomized trial. Patients undergoing endoscopic retrograde cholangiopancreatography (ERCP) procedures in which treatment was anticipated were randomly assigned to the V-system or to a conventional duodenoscope and accessories used routinely in each center. The parameters recorded included the total case time, fluoroscopy time, catheter/guide wire exchange time, guide wire repositioning, loss of guide wire access, and success or failure of guide wire fixation when using the V-system. Fifty patients were included, 22 in the conventional group and 28 in the V-system group. A total of 135 exchanges were carried out. The patients had up to six exchanges. The median exchange time was 19.4 s with the V-system and 31.7 s with the conventional systems ( P < 0.001). Guide wire repositioning was required less often in the V-system group ( P = 0.0005). The V-system effectively locked the guide wire in 63 of 71 exchanges (89 %). Loss of guide wire access occurred in two patients in the conventional group and four in the V-system group, attributable to failure to lock the guide wire early during the experience (no significant differences). The V-system can effectively secure the guide wire during accessory exchange in ERCP and reduces the time required to exchange accessories. This may enhance overall efficiency during ERCP.

  7. Comparison of microbubble presence in the right heart during mechanochemical and radiofrequency ablation for varicose veins.

    PubMed

    Moon, K H; Dharmarajah, B; Bootun, R; Lim, C S; Lane, Tra; Moore, H M; Sritharan, K; Davies, A H

    2017-07-01

    Objective Mechanochemical ablation is a novel technique for ablation of varicose veins utilising a rotating catheter and liquid sclerosant. Mechanochemical ablation and radiofrequency ablation have no reported neurological side-effect but the rotating mechanism of mechanochemical ablation may produce microbubbles. Air emboli have been implicated as a cause of cerebrovascular events during ultrasound-guided foam sclerotherapy and microbubbles in the heart during ultrasound-guided foam sclerotherapy have been demonstrated. This study investigated the presence of microbubbles in the right heart during varicose vein ablation by mechanochemical abaltion and radiofrequency abaltion. Methods Patients undergoing great saphenous vein ablation by mechanochemical abaltion or radiofrequency ablation were recruited. During the ablative procedure, the presence of microbubbles was assessed using transthoracic echocardiogram. Offline blinded image quantification was performed using International Consensus Criteria grading guidelines. Results From 32 recruited patients, 28 data sets were analysed. Eleven underwent mechanochemical abaltion and 17 underwent radiofrequency abaltion. There were no neurological complications. In total, 39% (11/28) of patients had grade 1 or 2 microbubbles detected. Thirty-six percent (4/11) of mechanochemical abaltion patients and 29% (5/17) of radiofrequency ablation patients had microbubbles with no significant difference between the groups ( p=0.8065). Conclusion A comparable prevalence of microbubbles between mechanochemical abaltion and radiofrequency ablation both of which are lower than that previously reported for ultrasound-guided foam sclerotherapy suggests that mechanochemical abaltion may not confer the same risk of neurological events as ultrasound-guided foam sclerotherapy for treatment of varicose veins.

  8. Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein.

    PubMed

    Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita

    2016-10-01

    Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common carotid artery and internal jugular vein (IJV), closely abutting the wall of both vessels. The guide wire was coiled with end coursing behind the esophageal wall. Guide wire was removed under fluoroscopic guide manipulation under local anesthesia. We want to emphasize that even though CVC placement is common and simple procedure, serious complication can occur in hands of untrained operator. The procedure should be performed under supervision, if done by trainee. Force should never be applied to advance the guide wire if resistance is encountered.

  9. TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamb, J; Low, D; Mutic, S

    Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency ofmore » 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was funded by ViewRay, Inc., Oakwood, OH.« less

  10. Operation and force analysis of the guide wire in a minimally invasive vascular interventional surgery robot system

    NASA Astrophysics Data System (ADS)

    Yang, Xue; Wang, Hongbo; Sun, Li; Yu, Hongnian

    2015-03-01

    To develop a robot system for minimally invasive surgery is significant, however the existing minimally invasive surgery robots are not applicable in practical operations, due to their limited functioning and weaker perception. A novel wire feeder is proposed for minimally invasive vascular interventional surgery. It is used for assisting surgeons in delivering a guide wire, balloon and stenting into a specific lesion location. By contrasting those existing wire feeders, the motion methods for delivering and rotating the guide wire in blood vessel are described, and their mechanical realization is presented. A new resistant force detecting method is given in details. The change of the resistance force can help the operator feel the block or embolism existing in front of the guide wire. The driving torque for rotating the guide wire is developed at different positions. Using the CT reconstruction image and extracted vessel paths, the path equation of the blood vessel is obtained. Combining the shapes of the guide wire outside the blood vessel, the whole bending equation of the guide wire is obtained. That is a risk criterion in the delivering process. This process can make operations safer and man-machine interaction more reliable. A novel surgery robot for feeding guide wire is designed, and a risk criterion for the system is given.

  11. MR-compatible polyetheretherketone-based guide wire assisting MR-guided stenting of iliac and supraaortic arteries in swine: feasibility study.

    PubMed

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz

    2009-01-01

    The purpose of this study was to demonstrate first magnetic resonance (MR)-guided stenting of iliac and supraaortic arteries using a polyetheretherketone-based (PEEK) MR-compatible guide wire. In vitro and animal experiments were performed in a short magnet wide-bore scanner (1.5 Tesla, Espree, Siemens Healthcare, Erlangen, Germany). For all experiments, a 0.035'' MR-compatible guide wire prototoype was used. This wire had a compound core of PEEK with reinforcing fibres, a soft and atraumatic tip and a hydrophilic coating. For its passive visualization, paramagnetic markings were attached. All experiments were performed through a vascular introducer sheath under MR-guidance. In vitro repetitive selective over the wire catheterizations of either the right carotid artery and the left subclavian artery were performed. In vivo, selective catheterization and over-the-wire stenting of the brachiocephalic trunk and the left subclavian artery were performed. The common iliac arteries were catheterized retrogradely (left) and cross-over (right). Angioplasty and stenting were performed over-the-wire. All procedures were successful. Visibility of the PEEK-based guide-wire was rated good in vitro and acceptable in vivo. Guide wire pushability and endovascular device support were good. The PEEK-based MR-compatible guide wire is well visible and usable under MR-guidance. It supports over-the-wire treatment of iliac arteries and supraaortic arteries.

  12. Use of Flexible Cystoscopy to Insert a Foley Catheter over a Guide Wire in Spinal Cord Injury Patients: Special Precautions to be Observed.

    PubMed

    Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Oo, Tun

    2011-01-01

    When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1) Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5-10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2) Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3) Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire.

  13. Use of Flexible Cystoscopy to Insert a Foley Catheter over a Guide Wire in Spinal Cord Injury Patients: Special Precautions to be Observed

    PubMed Central

    Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Oo, Tun

    2011-01-01

    When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1) Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5–10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2) Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3) Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire. PMID:22110492

  14. Accurate guide wire of lag screw placement in the intertrochanteric fractures: a technical note.

    PubMed

    Li, Jiang; Wang, Liao; Li, Xiaodong; Feng, Kai; Tang, Jian; Wang, Xiaoqing

    2017-09-01

    Cephalomedullary fixations are commonly used in the treatment of intertrochanteric fractures. In clinical practice, one of the difficulties is when we exit the guide wire in a wrong position of femoral neck and insert near the hole again, the guide wire often flow into the previous track. This study develops a surgical technique to direct the guide wire to slip away the previous track and slip into a right position. When guide wire is exited to the cortex of femoral, we let the wire in and out at the cortical layer for several times to enlarge the entry hole. After that, electric drill is inverted, rubbed and entered slowly at a right angle. When guide wire encountered new resistance, the electric drill is turned back instantly. This technique can help trauma and orthopedic surgeons to obtain precision placement of the lag screw after the first try is failed.

  15. A new catheter design for combined radiofrequency ablation and optoacoustic treatment monitoring using copper-coated light-guides

    NASA Astrophysics Data System (ADS)

    Rebling, Johannes; Oyaga Landa, Francisco Javier; Deán-Ben, Xosé Luis; Razansky, Daniel

    2018-02-01

    Electrosurgery, i.e. the application of radiofrequency current for tissue ablation, is a frequently used treatment for many cardiac arrhythmias. Electrophysiological and anatomic mapping, as well as careful radiofrequency power control typically guide the radiofrequency ablation procedure. Despite its widespread application, accurate monitoring of the lesion formation with sufficient spatio-temporal resolution remains challenging with the existing imaging techniques. We present a novel integrated catheter for simultaneous radiofrequency ablation and optoacoustic monitoring of the lesion formation in real time and 3D. The design combines the delivery of both electric current and optoacoustic excitation beam in a single catheter consisting of copper-coated multimode light-guides and its manufacturing is described in detail. The electrical current causes coagulation and desiccation while the excitation light is locally absorbed, generating OA responses from the entire treated volume. The combined ablation-monitoring capabilities were verified using ex-vivo bovine tissue. The formed ablation lesions showed a homogenous coagulation while the ablation was monitored in realtime with a volumetric frame rate of 10 Hz over 150 seconds.

  16. Ultrasonic Guided Waves for Aging Wire Insulation Assessment

    NASA Technical Reports Server (NTRS)

    Anastasi, Robert F.; Madaras, Eric I.

    2001-01-01

    Environmentally aged wire insulation can become brittle and crack and thus expose the underlying conductive wire to the potential for short circuits and fire. The feasibility of using ultrasonic guided waves to measure insulation condition was examined. First a simple model to study guided wave propagation in a bare and thin plastic coated wire was examined and then some aviation grade wire samples that had been heat-damaged. Initial measurements indicate that ultrasonic guided wave velocity can be used to monitor insulation stiffness.

  17. Computerized tomography-guided sphenopalatine ganglion pulsed radiofrequency treatment in 16 patients with refractory cluster headaches: Twelve- to 30-month follow-up evaluations.

    PubMed

    Fang, Luo; Jingjing, Lu; Ying, Shen; Lan, Meng; Tao, Wang; Nan, Ji

    2016-02-01

    Sphenopalatine ganglion percutaneous radiofrequency thermocoagulation treatment can improve the symptoms of cluster headaches to some extent. However, as an ablation treatment, radiofrequency thermocoagulation treatment also has side effects. To preliminarily evaluate the efficacy and safety of a non-ablative computerized tomography-guided pulsed radiofrequency treatment of sphenopalatine ganglion in patients with refractory cluster headaches. We included and analysed 16 consecutive cluster headache patients who failed to respond to conservative therapy from the Pain Management Center at the Beijing Tiantan Hospital between April 2012 and September 2013 treated with pulsed radiofrequency treatment of sphenopalatine ganglion. Eleven of 13 episodic cluster headaches patients and one of three chronic cluster headaches patient were completely relieved of the headache within an average of 6.3 ± 6.0 days following the treatment. Two episodic cluster headache patients and two chronic cluster headache patients showed no pain relief following the treatment. The mean follow-up time was 17.0 ± 5.5 months. All patients enrolled in this study showed no treatment-related side effects or complications. Our data show that patients with refractory episodic cluster headaches were quickly, effectively and safely relieved from the cluster period after computerized tomography-guided pulsed radiofrequency treatment of sphenopalatine ganglion, suggesting that it may be a therapeutic option if conservative treatments fail. © International Headache Society 2015.

  18. Retrieval of a subintimal fractured guide wire from the brachial artery following saphenous vein graft stenting.

    PubMed

    Danson, Edward J; Ward, Michael

    2015-06-01

    We present a case of a 58-year-old woman with diabetes mellitus with a history of angina, coronary artery bypass 24 years previously and who underwent retrieval of a fractured coronary buddy wire from the right brachial artery following attempted coronary intervention to a saphenous vein graft via the right radial route. Attempted removal of the guide wire had caused guide catheter-induced dissection of the vein graft in addition to a distal stent edge dissection before fracture in the brachial artery. The fractured end of the buddy wire was found to be in the subintimal space and could only be retrieved by advancing the wire into the subclavian artery by means of wrapping its free portion around the guiding catheter. Its fractured end could then be snared into the guiding catheter but could only be withdrawn from behind the stented segment in the vein graft by means of a trap balloon in the guiding catheter. Successful stenting of a guide catheter-induced dissection and distal stent edge dissection within the vein graft was then performed. This case highlights the hazards of deploying stents over buddy wires and of fractured guide wires in coronary intervention. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  19. New concepts and materials for the manufacturing of MR-compatible guide wires.

    PubMed

    Brecher, Christian; Emonts, Michael; Brack, Alexander; Wasiak, Christian; Schütte, Adrian; Krämer, Nils; Bruhn, Robin

    2014-04-01

    This paper shows the development of a new magnetic resonance imaging (MRI)-compatible guide wire made from fiber-reinforced plastics. The basic material of the developed guide wire is manufactured using a specially developed micro-pullwinding technology, which allows the adjustment of tensile, bending, and torsional stiffness independent from each other. Additionally, the micro-pullwinding technology provides the possibility to vary the stiffness along the length of the guide wire in a continuous process. With the possibilities of this technology, the mechanical properties of the guide wire were precisely adjusted for the intended usage in MRI-guided interventions. The performance of the guide wire regarding the mechanical properties was investigated. It could be shown, that the mechanical properties could be changed independently from each other by varying the process parameters. Especially, the torsional stiffness could be significantly improved with only a minor influence on bending and tensile properties. The precise influence of the variation of the winding angle on the mechanical and geometrical properties has to be further investigated. The usability of the guide wire as well as its visibility in MRI was investigated by radiologists. With the micro-pullwinding technology, a continuous manufacturing technique for highly stressable, MRI-safe profiles is available and can be the trigger for a new class of medical devices.

  20. Basic Wiring. Fourth Edition. Teacher Edition [and] Student Guide [and] Student Workbook 1 [and] Student Workbook 2.

    ERIC Educational Resources Information Center

    Kaltwasser, Stan; Flowers, Gary; Blasingame, Don

    Basic Wiring, first in a series of three wiring publications, serves as the foundation for students enrolled in a wiring program. It is a prerequisite to Commercial and Industrial Wiring or Residential Wiring. Instructional materials include a teacher edition, student guide, and two student workbooks. The teacher edition begins with introductory…

  1. Management of Retained Intervention Guide-wire: A Literature Review

    PubMed Central

    Al-Moghairi, Abdulrahman M; Al-Amri, Hussein S

    2013-01-01

    Percutaneous coronary angioplasty is increasingly employed in the treatment of patients with complex coronary artery disease. Different steerable guide wires used to open occluded vessel and facilitate balloon and stent deployment. However, the guide-wire itself is not without hazard: it may perforate or dissect the vessel, but fracture or entrapment is uncommon. Its management depends on the clinical situation of the patient, as well as the position and length of the remnant. In this review we discuss the angioplasty guide-wire fracture and entrapment risk factors, potential risks and management. PMID:23116055

  2. Electrode carrying wire for GTAW welding

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E. (Inventor); Dyer, Gerald E. (Inventor)

    1990-01-01

    A welding torch for gas tungsten arc welding apparatus has a hollow tungsten electrode including a ceramic liner and forms the filler metal wire guide. The wire is fed through the tungsten electrode thereby reducing the size of the torch to eliminate clearance problems which exist with external wire guides. Since the wire is preheated from the tungsten more wire may be fed into the weld puddle, and the wire will not oxidize because it is always within the shielding gas.

  3. Development of Active Catheter,Active Guide Wire and Micro Sensor Systems

    PubMed Central

    Haga, Y.; Mineta, T.; Totsu, K.; Makishi, W.; Esashi, M.

    2001-01-01

    Summary Active catheters and active guide wires which move like a snake have been developed for catheter-based minimally invasive diagnosis and therapy. Communication and control IC chips in the active catheter reduce the number of lead wires for control. The active catheter can be not only bent but also torsioned and extended. An ultra minature fiber-optic pressure sensor; a forward-looking ultrasonic probe and a magnetic position and orientation sensor have been developed for catheters and guide wires. These moving mechanisms and several sensors which are fitted near the tip of the catheter and the guide wire will provide detailed information near the tip and enable delicate and effective catheter intervention. PMID:20663389

  4. Intravascular ultrasound guided wiring re-entry technique for complex chronic total occlusions.

    PubMed

    Huang, Wei-Chieh; Teng, Hsin-I; Hsueh, Chien-Hung; Lin, Shing-Jong; Chan, Wan-Leong; Lu, Tse-Min

    2018-05-03

    The successful recanalization rate of chronic total occlusion (CTO) lesions without retrograde collaterals available is always low. Intravascular ultrasound (IVUS) may be useful to guide the subintimal guidewire to re-enter the true lumen. We evaluated the clinical feasibility and efficacy of the IVUS-guided wiring re-entry technique for these complex CTO lesions. Twenty consecutive patients (19 male, mean age: 65.3 ± 12.8 years) with both failed antegrade and retrograde approaches were enrolled. The IVUS catheter was introduced into the subintimal space to identify the entry point into the subintimal space, and guide another stiff wire to re-enter the true lumen with the adjacent side-branch or first wire as markers, or using IVUS-guided parallel wire technique. The entry point into the subintimal space was identified by IVUS in all cases, and the IVUS-guided wiring re-entry technique succeeded in 17 cases (85%). No procedure-related complication was noted except one case of delayed cardiac tamponade due to the wire perforation. During the mean follow-up period of 1.9 ± 1.3 years, there was no adverse cardiac event, except one patient died of the complication of cardiac transplantation. The IVUS-guided wiringre-entry technique might be feasible and safe for the recanalization of complex CTO lesions. © 2018, Wiley Periodicals, Inc.

  5. Residential Wiring. Fourth Edition. Teacher Edition [and] Student Guide [and] Student Workbook.

    ERIC Educational Resources Information Center

    Taylor, Mark

    Residential Wiring, the second publication in a series of three wiring publications, prepares students for entry-level employment in the residential wiring trade. Instructional materials include a teacher edition, student guide, and student workbook. The teacher edition begins with introductory pages, including a training and competency profile,…

  6. Waveguide bends from nanometric silica wires

    NASA Astrophysics Data System (ADS)

    Tong, Limin; Lou, Jingyi; Mazur, Eric

    2005-02-01

    We propose to use bent silica wires with nanometric diameters to guide light as optical waveguide bend. We bend silica wires with scanning tunneling microscope probes under an optical microscope, and wire bends with bending radius smaller than 5 μm are obtained. Light from a He-Ne laser is launched into and guided through the wire bends, measured bending loss of a single bend is on the order of 1 dB. Brief introductions to the optical wave guiding and elastic bending properties of silica wires are also provided. Comparing with waveguide bends based on photonic bandgap structures, the waveguide bends from silica nanometric wires show advantages of simple structure, small overall size, easy fabrication and wide useful spectral range, which make them potentially useful in the miniaturization of photonic devices.

  7. Base-level management of radio-frequency radiation-protection program. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rademacher, S.E.; Montgomery, N.D.

    1989-04-01

    AFOEHL developed this report to assist the base-level aerospace medical team manage their radio-frequency radiation-protection program. This report supersedes USAFOEHL Report 80-42, 'A Practical R-F Guide for BEES.'

  8. Base-level management of radio-frequency radiation-protection program. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rademacher, S.E.; Montgomery, N.D.

    1989-04-01

    AFOEHL developed this report to assist the base-level aerospace medical team manage their radio-frequency radiation protection program. This report supersedes USAFOEHL Report 80-42, 'A practical R-F Guide for BEES.'

  9. [Use of esophageal small balloon or papillary sphincter knife in the treatment of stent implantation 
for colorectal malignant obstruction].

    PubMed

    Xiao, Dinghua; Liu, Shaojun; Yan, Hanguang; Wang, Xiaoyan

    2018-05-28

    To explore the function of esophageal small balloon or papillary sphincter knife in the treatment of stent implantation for colorectal malignant obstruction, and to improve the success rate of colonic stent placement in such patients.
 Methods: A total of 49 patients with colorectal cancer complicated with almost complete obstruction or colorectal cancer were enrolled for this study. The esophageal small balloon or papillary sphincter knife was used in the guide wires. The guide wires gradually crossed the tumor gap and they were placed in the contralateral intestinal cavity with balloon progression. X-ray was then used to confirm whether the guide wire was inserted in the lesion intestinal cavity, and then the metal bare stent was inserted.
 Results: The guide wires was successfully inserted with conventional methods in these 49 cases, while they were also successfully placed the guide wire and the stent in the new way.
 Conclusion: For the patients with colorectal cancer complicated with complete obstruction or colorectal cancer located in obviously angled location, the use of esophageal small balloon or papillary sphincter knife can help the guide wire insert. They greatly improve the success rate of stent implantation.

  10. Commercial and Industrial Wiring. Fourth Edition. Teacher Edition [and] Student Guide [and] Student Workbook 1 [and] Student Workbook 2.

    ERIC Educational Resources Information Center

    Kaltwasser, Stan; Flowers, Gary

    Commercial and Industrial Wiring, third in a series of three wiring publications, includes the additional technical knowledge and applications required for job entry in the commercial and industrial wiring trade. Instructional materials include a teacher edition, student guide, and two student workbooks. The teacher edition begins with…

  11. Guide wire entrapment by inferior vena cava filters: an experimental study.

    PubMed

    Rosen, Michael J; Burns, Justin M; Cobb, William S; Jacobs, David G; Heniford, B Todd; Sing, Ronald F

    2005-09-01

    In situ vena cava filters are at risk for complications with the use of J-tipped guide wires. The purpose of this study was to evaluate the impact of two commonly used J-tipped guide wires on the stability of the four most recently released vena cava filters in an in vitro flow model. Four filters (OptEase [F1], Günther Tulip [F2], Vena Tech LP [F3], and Recovery [F4]) were inserted into an in vitro flow model. Two J-tipped guide wires (0.032-inch [GW-1], 0.035-inch [GW-2]) were passed through each filter (n = 50 passes per wire) for a distance of 10 cm. The inserter was blind as to the effects of the wire. The filters were monitored by an independent observer for adverse events occurring between the filters and the guide wires. These were defined as: migrations (>1 cm), change of position (tilt>10 degrees), and entrapment of the wire (unable to remove wire). Descriptive statistics, chi-square, and Fisher's exact test were used (p < 0.05 considered significant). GW-1 resulted in a lower incidence of entrapment, migration, and tilt for all filters compared with GW-2 (F1, p = 0.003; F2, p < 0.0001; F3, p < 0.0001; F4, p = 0.0004). GW-1 resulted in entrapment in 0%, migration in 7.5%, and tilt in 10.5% of insertions. GW-2 resulted in entrapment in 1%, migration in 26.5%, and tilt in 5.5% of insertions. The incidence of adverse events for GW-1 was significantly different compared with all filters (F1, 0%; F2, 46%; F3, 4%; and F4, 22%; p < 0.0001). Similarly, the incidence of adverse events for GW-2 was significantly different when evaluating all filters (F1, 12%; F2, 48%; F3, 22%; F4 60%; p < 0.0001). The smaller-diameter guide wire resulted in a decreased incidence of adverse events for all filters, but there is still risk for complications. Knowledge of potential complications associated with vena cava filters and the postinsertion use of guide wires are essential to avoid potential mishaps.

  12. Wire-guided sphincterotomy.

    PubMed

    Sherman, S; Uzer, M F; Lehman, G A

    1994-12-01

    Guidewire-assisted techniques have acquired an important role in endoscopic interventions in the pancreaticobiliary tree. The wire-guided sphincterotome allows the endoscopist to maintain direct access to the biliary tree before or after the sphincterotomy. It has the additional advantages of allowing for more expeditious placement of accessories and being useful in combined percutaneous-endoscopic procedures. There are two basic designs of wire-guided sphincterotomes. The single-channel model has a single lumen for both the cutting wire and guidewire and requires guidewire removal before the application of power. The double-channel model has two separate lumens for the guidewire and stainless steel cutting wire. In vitro data suggest that significant capacitive coupling currents (or short circuits) may occur on the standard Teflon-coated guidewire when used with a double lumen sphincterotome, resulting in electrosurgical burns. Thus, the manufacturers of the double-lumen models recommend removing the Teflon-coated wire before performing sphincterotomy. Although limited data in humans have been published, it appears that wire-guided sphincterotomy and standard sphincterotomy have similar complication rates. More safety information in humans is awaited.

  13. Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdel-Aal, Ahmed Kamel, E-mail: akamel@uabmc.edu; Saddekni, Souheil; Hamed, Maysoon Farouk

    Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of anmore » IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.« less

  14. Simulation of minimally invasive vascular interventions for training purposes.

    PubMed

    Alderliesten, Tanja; Konings, Maurits K; Niessen, Wiro J

    2004-01-01

    To master the skills required to perform minimally invasive vascular interventions, proper training is essential. A computer simulation environment has been developed to provide such training. The simulation is based on an algorithm specifically developed to simulate the motion of a guide wire--the main instrument used during these interventions--in the human vasculature. In this paper, the design and model of the computer simulation environment is described and first results obtained with phantom and patient data are presented. To simulate minimally invasive vascular interventions, a discrete representation of a guide wire is used which allows modeling of guide wires with different physical properties. An algorithm for simulating the propagation of a guide wire within a vascular system, on the basis of the principle of minimization of energy, has been developed. Both longitudinal translation and rotation are incorporated as possibilities for manipulating the guide wire. The simulation is based on quasi-static mechanics. Two types of energy are introduced: internal energy related to the bending of the guide wire, and external energy resulting from the elastic deformation of the vessel wall. A series of experiments were performed on phantom and patient data. Simulation results are qualitatively compared with 3D rotational angiography data. The results indicate plausible behavior of the simulation.

  15. Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire.

    PubMed

    Metikala, Sreenivasulu; Mohammed, Riazuddin

    2011-07-01

    Extracting broken segments of intramedullay nails from long bones can be an operative challenge, particularly from the distal end. We report a case series where a simple and reproducible technique of extracting broken femoral cannulated nails using a ball-tipped guide wire is described. This closed technique involves no additional equipment or instruments. Eight patients who underwent the described method were included in the study. The technique involves using a standard plain guide wire passed through the cannulated distal broken nail segment after extraction of the proximal nail fragment. The plain guide wire is then advanced distally into the knee joint carefully under fluoroscopy imaging. Over this wire, a 5-millimeter (mm) cannulated large drill bit is used to create a track up to the distal broken nail segment. Through the small knee wound, a ball-tipped guide wire is passed, smooth end first, till the ball engages the end of the nail. The guide wire is then extracted along with the broken nail through the proximal wound. The method was successfully used in all eight patients for removal of broken cannulated intramedullary nail from the femoral canal without any complications. All patients underwent exchange nailing with successful bone union in six months. None of the patients had any problems at the knee joint at the final follow-up. We report a technique for successful extraction of the distal fragment of broken femoral intramedullary nails without additional surgical approaches.

  16. Use of a very flexible guide wire to permit dilation of complex malignant strictures of the esophagus.

    PubMed

    Vargas-Tank, L; Ovalle, L; Fernández, C; Mella, B; Estay, R; del Solar, M P; Soto, J R

    1995-01-01

    Risk of perforation is a major impediment to the use of polyvinyl bougies in palliative dilation of cancerous strictures of the esophagus. We encountered 23 patients with complex malignant strictures in whom initial dilation with Savary-Gilliard bougies was thwarted because attempts to pass a conventional Eder-Puestow guide wire were unsuccessful. As a recourse, we probed these strictures with a very flexible guide wire of the type used to implant prostheses in the biliary tract. The purpose was to establish a passage through which a standard guide wire could then be inserted. The procedure was successful in all but 4 of the 23 patients. We conclude that in such cases the preliminary use of the very flexible guide, even though time-consuming, improves the chance of effective dilation with minimal added risk.

  17. Plasma arc torch with coaxial wire feed

    DOEpatents

    Hooper, Frederick M

    2002-01-01

    A plasma arc welding apparatus having a coaxial wire feed. The apparatus includes a plasma arc welding torch, a wire guide disposed coaxially inside of the plasma arc welding torch, and a hollow non-consumable electrode. The coaxial wire guide feeds non-electrified filler wire through the tip of the hollow non-consumable electrode during plasma arc welding. Non-electrified filler wires as small as 0.010 inches can be used. This invention allows precision control of the positioning and feeding of the filler wire during plasma arc welding. Since the non-electrified filler wire is fed coaxially through the center of the plasma arc torch's electrode and nozzle, the wire is automatically aimed at the optimum point in the weld zone. Therefore, there is no need for additional equipment to position and feed the filler wire from the side before or during welding.

  18. Mountain Plains Learning Experience Guide: Electrical Wiring. Course: Electrical Wiring Trim-Out.

    ERIC Educational Resources Information Center

    Arneson, R.; And Others

    One of two individualized courses included in an electrical wiring curriculum, this course covers electrical materials installation for the trim-out stage. The course is comprised of five units: (1) Outlets, (2) Fixtures, (3) Switches, (4) Appliances, and (5) Miscellaneous. Each unit begins with a Unit Learning Experience Guide that gives…

  19. Sphincterotomy by triple lumen needle knife using guide wire in patients with Billroth II gastrectomy

    PubMed Central

    Park, Su Bum; Kim, Hyung Wook; Kang, Dae Hwan; Choi, Cheol Woong; Yoon, Ki Tae; Cho, Mong; Song, Byeong Jun

    2013-01-01

    AIM: To investigate the usefulness of a guide wire and triple lumen needle knife for removing stones in Billroth II (B-II) gastrectomy patients. METHODS: Endoscopic sphincterotomy in patients with B-II gastrectomy is challenging. We used a new guide wire technique involving sphincterotomy by triple lumen needle knife through a forward-viewing endoscopy. This technique was performed in nine patients between August 2010 and June 2012. Sphincterotomy as described above was performed. Adequate sphincterotomy, successful stone removal, and complications were investigated prospectively. RESULTS: Sphincterotomy by triple lumen needle knife using guide wire was successful in all nine patients. Sphincterotomy started towards the 4-5 o’clock direction and continued to the upper margin of the papillary roof. Complete stone removal in one session was achieved in all patients. There were no procedure related complications, such as bleeding, pancreatitis, or perforation. CONCLUSION: In patients with B-II gastrectomy, guide wire using sphincterotomy by triple lumen needle knife through a forward-viewing endoscopy seems to be an effective and safe procedure for the removal of common bile duct stones. PMID:24409069

  20. Pre-operative localization of solitary pulmonary nodules with computed tomography-guided hook wire: report of 181 patients.

    PubMed

    Hanauer, Matthieu; Perentes, Jean Yannis; Krueger, Thorsten; Ris, Hans-Beat; Bize, Pierre; Schmidt, Sabine; Gonzalez, Michel

    2016-01-16

    Video-assisted thoracic surgery (VATS) is currently performed to diagnose and treat solitary pulmonary nodules (SPN). However, the intra-operative identification of deep nodules can be challenging with VATS as the lung is difficult to palpate. The aim of the study was to report the utility and the results of pre-operative computed tomography (CT)-guided hook wire localization of SPN. All records of the patients undergoing CT-guided hook wire localization prior to VATS resection for SPN between 2002 and 2013 were reviewed. The efficacy in localizing the nodule, hook wire complications, necessity to convert VATS to thoracotomy and the histology of SPN are reported. One hundred eighty-one patients (90 females, mean age 63 y, range 28-82 y) underwent 187 pulmonary resections after CT-guided hook wire localization. The mean SPN diameter was 10.3 mm (range: 4-29 mm). The mean distance of the lesion from the pleural surface was 11.6 mm (range: 0-45 mm). The mean time interval from hook wire insertion to VATS resection was 224 min (range 54-622 min). Hook wire complications included pneumothorax requiring chest tube drainage in 4 patients (2.1%) and mild parenchymal haemorrhage in 11 (5.9%) patients. Migration of the hook wire occurred in 7 patients (3.7%) although it did not affect the success of VATS resection (nodule location guided by the lung puncture site). Three patients underwent additional wedge resection by VATS during the same procedure because no lesion was identified in the surgical specimen. Conversion thoracotomy was required in 13 patients (7 %) for centrally localized lesions (6 patients) and pleural adhesions (7 patients). The mean operative time was 60 min (range 18-135 min). Pathological examination revealed a malignant lesion in 107 patients (59 %). The diagnostic yield was 98.3 %. VATS resection for SPN after CT-guided hook wire localization for SPN is safe and allows for proper diagnosis with a low thoracotomy conversion rate.

  1. 75 FR 80827 - Compliance Policy Guide; Radiofrequency Identification Feasibility Studies and Pilot Programs for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-23

    ... Identification (RFID) Feasibility Studies and Pilot Programs for Drugs'' to December 31, 2012. FOR FURTHER... Sec. 400.210 entitled ``Radiofrequency Identification (RFID) Feasibility Studies and Pilot Programs... FR 65750, November 23, 2007; 73 FR 78371, December 22, 2008). FDA has identified RFID as a promising...

  2. A simple customized surgical guide for orthodontic miniplates with tube.

    PubMed

    Paek, Janghyun; Su, Ming-Jeaun; Kwon, Soon-Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

    2012-09-01

    This article reports the use of a customized surgical guide for simple and precise C-tube plate placement with minimized incision. Patients who were planning to have orthodontic miniplate treatment because of narrow interradicular space were recruited for this study. A combined silicone and stainless steel wire surgical guide for the C-tube was fabricated on the cast model. The taller wire of the positioning guide is used to accurately start the incision. The incision guide-wire position is verified by placing the miniplate on the coronal horizontal wire to confirm that the incision will coordinate with the screw holes. Because the miniplate is firmly held in place, there is no risk of the miniplate anchoring screws (diameter, 1.5 mm; length, 4 mm) sliding on the bone surface during placement with a manual hand driver. The surgical guide was placed on the clinical site, and it allowed precise placement of the miniplate with minimum incision and preventing from slippage or path-of-insertion angulation errors that might interfere with accurate placement. Customized surgical guide enables precise planning for miniplate positions in anatomically complex sites.

  3. Development of a smart guide wire using an electrostrictive polymer: option for steerable orientation and force feedback

    NASA Astrophysics Data System (ADS)

    Ganet, F.; Le, M. Q.; Capsal, J. F.; Lermusiaux, P.; Petit, L.; Millon, A.; Cottinet, P. J.

    2015-12-01

    The development of steerable guide wire or catheter designs has been strongly limited by the lack of enabling actuator technologies. This paper presents the properties of an electrostrive actuator technology for steerable actuation. By carefully tailoring material properties and the actuator design, which can be integrated in devices, this technology should realistically make it possible to obtain a steerable guide wire design with considerable latitude. Electromechanical characteristics are described, and their impact on a steerable design is discussed.

  4. Wire-Guide Manipulator For Automated Welding

    NASA Technical Reports Server (NTRS)

    Morris, Tim; White, Kevin; Gordon, Steve; Emerich, Dave; Richardson, Dave; Faulkner, Mike; Stafford, Dave; Mccutcheon, Kim; Neal, Ken; Milly, Pete

    1994-01-01

    Compact motor drive positions guide for welding filler wire. Drive part of automated wire feeder in partly or fully automated welding system. Drive unit contains three parallel subunits. Rotations of lead screws in three subunits coordinated to obtain desired motions in three degrees of freedom. Suitable for both variable-polarity plasma arc welding and gas/tungsten arc welding.

  5. Electricity: Residential Wiring. Secondary Schools. Curriculum Guide.

    ERIC Educational Resources Information Center

    Trust Territory of the Pacific Islands Dept. of Education, Saipan.

    This curriculum guide on residential wiring for secondary students is one of six developed for inservice teachers at Marianas High School in Saipan. The guide provides the rationale, description, goals, and objectives of the program; the program of studies and performance objectives by levels; samples of lesson plans for effective delivery of…

  6. Subarachnoid and basal cistern navigation through the sacral hiatus with guide wire assistance.

    PubMed

    Layer, Lauren; Riascos, Roy; Firouzbakht, Farhood; Amole, Adewumi; Von Ritschl, Rudiger; Dipatre, Pier; Cuellar, Hugo

    2011-07-01

    Intraspinal navigation with catheters and fiberscopes has shown feasible results for diagnosis and treatment of intraspinal and intracranial lesions. The most common approach, lumbar puncture, has allowed access to the spinal cord, however, coming with the difficulties of fiberscope damage and decreased torque for guidance. Our objective in this study is to allow an alternate access, the sacral hiatus, with guide wire assistance into the subarachnoid and intracranial structures, while easing the angle of entry and increasing torque. We advanced catheters with guide wire and fluoroscopy assistance into the sacral hiatus of three cadavers. After entry, the thecal sac was punctured and the catheter with guide wire was advanced rostrally until positioned in the basal cisterns of the brain. We confirmed catheter placement with contrast injection, autopsy, and dissection. In our study, the sacral hiatus was easily accessed, but resistance was found when attempting to puncture the thecal sac. The advancement of the catheter with guide wire assistance glided easily rostrally until some mild resistance was discovered at entry into the foramen magnum. With redirection, all catheters passed with ease into the basal cisterns. Positioning was confirmed with contrast injection with fluoroscopy evidence, autopsy, and dissection. There was no macroscopic or microscopic evidence of damage to the spinal roots, spinal cord, or cranial nerves. The sacral hiatus with guide wire assistance is an accessible conduit for uncomplicated entry into the subarachnoid and basal cistern space without damaging surrounding structures.

  7. Appropriate Use Criteria for Fluoroscopically Guided Diagnostic and Therapeutic Sacroiliac Interventions: Results from the Spine Intervention Society Convened Multispecialty Collaborative.

    PubMed

    MacVicar, John; Kreiner, D Scott; Duszynski, Belinda; Kennedy, David J

    2017-11-01

    To provide an overview of a multisociety effort to formulate appropriate use criteria for image-guided injections and radiofrequency procedures in the diagnosis and treatment of sacroiliac joint and posterior sacroiliac complex pain. The Spine Intervention Society convened a multisociety effort to guide physicians and define for payers the appropriate use of image-guided injections and radiofrequency procedures. An evidence panel was established to write systematic reviews, define key terms and assumptions, and develop clinical scenarios to be addressed. The rating panel considered the evidence presented in the systematic reviews, carefully reviewed the definitions and assumptions, and rated the clinical scenarios. Final median ratings, in combination with the level of agreement, determined the final ratings for the appropriate use of sacroiliac injections and radiofrequency neurotomy. More than 10,000 scenarios were addressed in the appropriate use criteria and are housed within five modules in the portal, available on the Spine Intervention Society website: Module 1: Clinical Indications and Imaging; Module 2: Anticoagulants; Module 3: Timing of Injections; Module 4: Number of Injections; and Module 5: Lateral Branch Radiofrequency Neurotomy. Within several of these modules, several issues of interest are identified and discussed. Physicians and payers can access the appropriate use criteria portal on the Spine Intervention Society's website and select specific clinical indications for a particular patient in order to learn more about the appropriateness of the intervention(s) under consideration. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. An EEG (electroencephalogram) recording system with carbon wire electrodes for simultaneous EEG-fMRI (functional magnetic resonance imaging) recording

    PubMed Central

    Negishi, Michiro; Abildgaard, Mark; Laufer, Ilan; Nixon, Terry; Constable, Robert Todd

    2008-01-01

    Simultaneous EEG-fMRI (Electroencephalography-functional Magnetic Resonance Imaging) recording provides a means for acquiring high temporal resolution electrophysiological data and high spatial resolution metabolic data of the brain in the same experimental runs. Carbon wire electrodes (not metallic EEG electrodes with carbon wire leads) are suitable for simultaneous EEG-fMRI recording, because they cause less RF (radio-frequency) heating and susceptibility artifacts than metallic electrodes. These characteristics are especially desirable for recording the EEG in high field MRI scanners. Carbon wire electrodes are also comfortable to wear during long recording sessions. However, carbon electrodes have high electrode-electrolyte potentials compared to widely used Ag/AgCl (silver/silver-chloride) electrodes, which may cause slow voltage drifts. This paper introduces a prototype EEG recording system with carbon wire electrodes and a circuit that suppresses the slow voltage drift. The system was tested for the voltage drift, RF heating, susceptibility artifact, and impedance, and was also evaluated in a simultaneous ERP (event-related potential)-fMRI experiment. PMID:18588913

  9. Coronary angioscopy: a monorail angioscope with movable guide wire.

    PubMed

    Nanto, S; Ohara, T; Mishima, M; Hirayama, A; Komamura, K; Matsumura, Y; Kodama, K

    1991-03-01

    A new angioscope was devised for easier visualization of the coronary artery. In its tip, the angioscope (Olympus) with an outer diameter of 0.8 mm had a metal lumen, through which a 0.014-in steerable guide wire passed. Using a 8F guiding catheter and a guide wire, it was introduced into the distal coronary artery. With injection of warmed saline through the guiding catheter, the coronary segments were visualized. In the attempted 70 vessels (32 left anterior descending [LAD], 10 right coronary [RCA], 28 left circumflex [LCX]) from 48 patients, 60 vessels (86%) were successfully examined. Twenty-two patients who underwent attempted examination of both LAD and LCX; both coronary arteries were visualized in 19 patients (86%). In the proximal site of the lesion, 40 patients have the diagonal branch or the obtuse marginal branch. In 34 patients (85%) the angioscope was inserted beyond these branches. In 12 very tortuous vessels, eight vessels (67%) were examined. In conclusion, the new monorail coronary angioscope with movable guide wire is useful to examine the stenotic lesions of the coronary artery.

  10. Enhanced Radiofrequency Ablation With Magnetically Directed Metallic Nanoparticles.

    PubMed

    Nguyen, Duy T; Tzou, Wendy S; Zheng, Lijun; Barham, Waseem; Schuller, Joseph L; Shillinglaw, Benjamin; Quaife, Robert A; Sauer, William H

    2016-05-01

    Remote heating of metal located near a radiofrequency ablation source has been previously demonstrated. Therefore, ablation of cardiac tissue treated with metallic nanoparticles may improve local radiofrequency heating and lead to larger ablation lesions. We sought to evaluate the effect of magnetic nanoparticles on tissue sensitivity to radiofrequency energy. Ablation was performed using an ablation catheter positioned with 10 g of force over prepared ex vivo specimens. Tissue temperatures were measured and lesion volumes were acquired. An in vivo porcine thigh model was used to study systemically delivered magnetically guided iron oxide (FeO) nanoparticles during radiofrequency application. Magnetic resonance imaging and histological staining of ablated tissue were subsequently performed as a part of ablation lesion analysis. Ablation of ex vivo myocardial tissue treated with metallic nanoparticles resulted in significantly larger lesions with greater impedance changes and evidence of increased thermal conductivity within the tissue. Magnet-guided localization of FeO nanoparticles within porcine thigh preps was demonstrated by magnetic resonance imaging and iron staining. Irrigated ablation in the regions with greater FeO, after FeO infusion and magnetic guidance, created larger lesions without a greater incidence of steam pops. Metal nanoparticle infiltration resulted in significantly larger ablation lesions with altered electric and thermal conductivity. In vivo magnetic guidance of FeO nanoparticles allowed for facilitated radiofrequency ablation without direct infiltration into the targeted tissue. Further research is needed to assess the clinical applicability of this ablation strategy using metallic nanoparticles for the treatment of cardiac arrhythmias. © 2016 American Heart Association, Inc.

  11. Evaluation of a novel, ultrathin, tip-bending endoscope in a synthetic force-sensing pancreas with comparison to medical guide wires

    PubMed Central

    Chandler, John E; Lee, Cameron M; Babchanik, Alexander P; Melville, C David; Saunders, Michael D; Seibel, Eric J

    2012-01-01

    Purpose Direct visualization of pancreatic ductal tissue is critical for early diagnosis of pancreatic diseases and for guiding therapeutic interventions. A novel, ultrathin (5 Fr) scanning fiber endoscope (SFE) with tip-bending capability has been developed specifically to achieve high resolution imaging as a pancreatoscope during endoscopic retrograde cholangiopancreatography (ERCP). This device has potential to dramatically improve both diagnostic and therapeutic capabilities during ERCP by providing direct video feedback and tool guidance to clinicians. Methods Invasiveness of the new tip-bending SFE was evaluated by a performance comparison to ERCP guide wires, which are routinely inserted into the pancreatic duct during ERCP. An in vitro test model with four force sensors embedded in a synthetic pancreas was designed to detect and compare the insertion forces for 0.89 mm and 0.53 mm diameter guide wires as well as the 1.7 mm diameter SFE. Insertions were performed through the working channel of a therapeutic duodenoscope for the two types of guide wires and using a statistically similar direct insertion method for comparison to the SFE. Results Analysis of the forces detected by the sensors showed the smaller diameter 0.53 mm wire produced significantly less average and maximum forces during insertion than the larger diameter 0.89 mm wire. With the use of tip-bending and optical visualization, the 1.7 mm diameter SFE produced significantly less average force during insertion than the 0.89 mm wire at every sensor, despite its larger size. It was further shown that the use of tip-bending with the SFE significantly reduced the forces at all sensors, compared to insertions when tip-bending was not used. Conclusion Combining high quality video imaging with two-axis tip-bending allows a larger diameter guide wire-style device to be inserted into the pancreatic duct during ERCP with improved capacity to perform diagnostics and therapy. PMID:23166452

  12. Graph-based geometric-iconic guide-wire tracking.

    PubMed

    Honnorat, Nicolas; Vaillant, Régis; Paragios, Nikos

    2011-01-01

    In this paper we introduce a novel hybrid graph-based approach for Guide-wire tracking. The image support is captured by steerable filters and improved through tensor voting. Then, a graphical model is considered that represents guide-wire extraction/tracking through a B-spline control-point model. Points with strong geometric interest (landmarks) are automatically determined and anchored to such a representation. Tracking is then performed through discrete MRFs that optimize the spatio-temporal positions of the control points while establishing landmark temporal correspondences. Promising results demonstrate the potentials of our method.

  13. Spring control of wire harness loops

    NASA Technical Reports Server (NTRS)

    Curcio, P. J.

    1979-01-01

    Negator spring control guides wire harness between movable and fixed structure. It prevents electrical wire harness loop from jamming or being severed as wire moves in response to changes in position of aircraft rudder. Spring-loaded coiled cable controls wire loop regardless of rudder movement.

  14. A novel technique to prevent guide wire related complications while inserting the 4.0 mm cannulated screws.

    PubMed

    Qi, Bao-Chang; Ju, Wei-Na; Wang, Tie-Jun; Yu, Tie-Cheng; Zhao, Yi; Sun, Da-Hui

    2015-01-01

    Cannulated screws (4.0 mm) provide inter-fragmentary compression and stability to fractures. A guide wire is used to define the screw trajectory and hold the fracture fragment while the screw is being inserted. The cannulated shaft typically accommodates a 1.25 mm guide pin. Since the guide pin is very slender and undergoes elastic deformation during insertion, there is a high probability of pin breakage. The authors have devised a new way to place the 4.0 mm cannulated screws in a manner that prevents the intraoperative complication of guide wire breakage. For this technique, predrilling was achieved using a 2.0 mm K-wire which was subsequently replaced with a 1.25 mm guide pin under the protection of sleeve. 4.0 mm cannulated screws were then inserted into a defined trajectory over the guide pin. Using the technique, over 20 patients were managed in our department over a period of two years without any complications. We have observed that patients treated with this method experience short operation time, combined with good clinical outcome and we recommend its use in cases where cannulated screw use is warranted.

  15. Aging Wire Insulation Assessment by Phase Spectrum Examination of Ultrasonic Guided Waves

    NASA Technical Reports Server (NTRS)

    Anastasi, Robert F.; Madaras, Eric I.

    2003-01-01

    Wire integrity has become an area of concern to the aerospace community including DoD, NASA, FAA, and Industry. Over time and changing environmental conditions, wire insulation can become brittle and crack. The cracks expose the wire conductor and can be a source of equipment failure, short circuits, smoke, and fire. The technique of using the ultrasonic phase spectrum to extract material properties of the insulation is being examined. Ultrasonic guided waves will propagate in both the wire conductor and insulation. Assuming the condition of the conductor remains constant then the stiffness of the insulator can be determined by measuring the ultrasonic guided wave velocity. In the phase spectrum method the guided wave velocity is obtained by transforming the time base waveform to the frequency domain and taking the phase difference between two waveforms. The result can then be correlated with a database, derived by numerical model calculations, to extract material properties of the wire insulator. Initial laboratory tests were performed on a simple model consisting of a solid cylinder and then a solid cylinder with a polymer coating. For each sample the flexural mode waveform was identified. That waveform was then transformed to the frequency domain and a phase spectrum was calculated from a pair of waveforms. Experimental results on the simple model compared well to numerical calculations. Further tests were conducted on aircraft or mil-spec wire samples, to see if changes in wire insulation stiffness can be extracted using the phase spectrum technique.

  16. Iatrogenic submucosal tunnel in the ureter: a rare complication during advancement of the guide wire.

    PubMed

    El Darawany, Hamed; Barakat, Alaa; Madi, Maha Al; Aldamanhori, Reem; Al Otaibi, Khalid; Al-Zahrani, Ali A

    2016-01-01

    Inserting a guide wire is a common practice during endo-urological procedures. A rare complication in patients with ureteral stones where an iatrogenic submucosal tunnel (IST) is created during endoscopic guide wire placement. Summarize data on IST. Retrospective descriptive study of patients treated from from October 2009 until January 2015. King Fahd Hospital of the University, Al-Khobar, Saudi Arabia. Patients with ureteral stones were divided to 2 groups. In group I (335 patients), the ureteral stones were removed by ureteroscopy in one stage. Group II (97 patients) had a 2-staged procedure starting with a double J-stent placement for kidney drainage followed within 3 weeks with ureteroscopic stone removal. Endoscopic visualization of ureteric submucosal tunneling by guide wire. IST occurred in 9/432 patients with ureteral stones (2.1%). The diagnosis in group I was made during ureteroscopy by direct visualization of a vanishing guide wire at the level of the stone (6 patients). In group II, IST was suspected when renal pain was not relieved after placement of the double J-stent or if imaging by ultrasound or intravenous urography showed persistent back pressure to the obstructed kidney (3 patients). The condition was subsequently confirmed by ureteroscopy. Forceful advancement of the guide wire in an inflamed and edematous ureteral segment impacted by a stone is probably the triggering factor for development of IST. Definitive diagnosis is possible only by direct visualization during ureteroscopy. Awareness of this potential complication is important to guard against its occurrence. Relatively small numbers of subjects and the retrospective nature of the study.

  17. Magnetic guide-wire navigation in pulmonary and systemic arterial catheterization: initial experience in pigs.

    PubMed

    Grosse-Wortmann, Lars; Grabitz, Ralf; Seghaye, Marie-Christine

    2007-04-01

    Cardiovascular catheterization can be challenging whenever a stenosis or an abnormal vascular course interferes with probing the target vessel. This study addresses the feasibility of navigating a guide wire with a magnetic tip by an external magnetic field through pulmonary and systemic arteries in an experimental porcine model. We investigated six piglets using magnetic guide-wire navigation. Two pulmonary arteriograms were taken from different angles in order to reconstruct the three-dimensional vessel anatomy. A computer interface then calculated three-dimensional coordinates for the vessel in space. Using these coordinates, two external magnets were positioned to create magnetic vectors along the expected vessel course. Magnetically enabled guide wires were then navigated into the vessels using the magnetic field to orient the guide-wire tips. Aortic and renal branches were addressed in a similar fashion. Difficulty in reaching the target vessel was reflected by the number of attempts that were necessary. After 10 failed attempts, the maneuver was recorded to have failed. Thirty-five of 37 (94.6%) arteries with branches at acute angles were reached successfully using magnetic navigation. In two pigs, the left upper lobe artery could not be probed. Peripheral arteries of small diameter were easier to reach than large central arteries, requiring less attempts. Magnetic guide-wire navigation is feasible in the arteries of the lungs, the head and neck, and the kidneys. It is particularly useful in entering small arterial branches at acute angles and may facilitate interventional therapy in a variety of vascular diseases in children and adults.

  18. Percutaneous thrombin injection treatment of a gluteal pseudoaneurysm following radiofrequency ablation of a hip osteoid osteoma in a 6-year-old boy.

    PubMed

    Kumar, Abhishek; Ramchand, Tekchand; Contractor, Sohail

    2014-12-01

    Osteoid osteomas are benign bone lesions that present with bone pain in children and young adults. Over the last 2 decades, radiofrequency ablation has become the mainstay of treatment and is now preferred over surgical resection. Major complications of the procedure are very rare, consisting mostly of local skin burns. We present a case of a child presenting with a gluteal pseudoaneursym following CT-guided radiofrequency ablation of an acetabular osteoid osteoma, which was then treated successfully with percutaneous thrombin injection.

  19. Study protocol for a randomised controlled trial of ultrasound-guided pulsed radiofrequency of the genicular nerves in the treatment of patients with osteoarthritis knee pain

    PubMed Central

    Valentí, Pedro; Hernández, Beatriz; Mir, Bartolome; Aguilar, Jose Luis

    2017-01-01

    Introduction The goals for the management of patients with osteoarthritis (OA) of the knee are to control pain and to minimise disability. Because the number of patients will increase as the population ages, alternative approaches to alleviate their joint pain other than conventional treatments are necessary. The purpose of this article is to present a refined protocol to determine if there is long-term improvement in pain and function after ultrasound-guided pulsed radiofrequency treatment of the genicular nerves (GNs) in patients with chronic painful knee OA. Methods and analysis This study is a randomised, double-blind, placebo-controlled, parallel design trial. One hundred and forty-two outpatients with OA of the knee will be recruited from Mallorca, Spain. Participants will be randomly allocated into two groups: ultrasound-guided sham GN pulsed radiofrequency without active treatment and ultrasound-guided real GN pulsed radiofrequency. The primary outcome measures will be the observed changes from baseline pain intensity based on visual analogue scale (VAS). The possible changes in the secondary efficacy variables from the baseline as assessed by the Goldberg Anxiety and Depression Scale, pain medication use, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC subscales) and VAS pain intensity are also to be included in the study. These variables will be assessed at baseline, 1 month, 3 months, 6 months and 1 year after treatment. Ethics and dissemination The protocol was approved by the Research Ethic Committee of the Balearic Islands (IB 3223/16 PI). The results will be disseminated in peer-reviewed journals and at scientific conferences. Trial registration Trial registration numberNCT02915120; Pre-results PMID:29102985

  20. Investigating the Use of Ultrasonic Guided Waves for Aging Wire Insulation Assessment

    NASA Technical Reports Server (NTRS)

    Anastasi, Robert F.; Madaras, Eric I.

    2002-01-01

    Aging wiring has become a critical issue to DoD, NASA, FAA, and Industry. The problem is that insulation on environmentally aged wire becomes brittle and cracks. This exposes the underlying conductive wire to the potential for short circuits and fire. The difficulty is that techniques to monitor aging wire problems focus on applying electrical sensing techniques that are not very sensitive to the wire insulation. Thus, the development of methods to quantify and monitor aging wire insulation is highly warranted. Measurement of wire insulation stiffness by ultrasonic guided waves is being examined. Initial laboratory tests were performed on a simple model consisting of a solid cylinder and then a solid cylinder with a polymer coating. Experimental measurements showed that the lowest order axisymmetric mode may be sensitive to stiffness changes in the wire insulation. To test this theory, mil-spec wire samples MIL-W-81381, MIL-W-22759/34, and MIL-W-22759/87 (typically found in aircraft) were heat-damaged in an oven, in a range of heating conditions. The samples were 12, 16, and 20 gauge and the heat-damage introduced material changes in the wire-insulation that made the originally flexible insulation brittle and darker in color. Axisymmetric mode phase velocity increased for the samples that were exposed to heat for longer duration. For example, the phase velocity in the 20-gauge MIL-W-22759/34 wire changed from a baseline value of 2790m/s to 3280m/s and 3530m/s for one-hour exposures to 3490C and 3990C, respectively. Although the heat-damage conditions are not the same as environmental aging, we believe that with further development and refinements, the ultrasonic guided waves can be used to inspect wire-insulation for detrimental environmental aging conditions.

  1. Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience.

    PubMed

    Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K

    2007-06-01

    Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  2. Rationale and design of the NO-PARTY trial: near-zero fluoroscopic exposure during catheter ablation of supraventricular arrhythmias in young patients.

    PubMed

    Casella, Michela; Dello Russo, Antonio; Pelargonio, Gemma; Bongiorni, Maria Grazia; Del Greco, Maurizio; Piacenti, Marcello; Andreassi, Maria Grazia; Santangeli, Pasquale; Bartoletti, Stefano; Moltrasio, Massimo; Fassini, Gaetano; Marini, Massimiliano; Di Cori, Andrea; Di Biase, Luigi; Fiorentini, Cesare; Zecchi, Paolo; Natale, Andrea; Picano, Eugenio; Tondo, Claudio

    2012-10-01

    Radiofrequency catheter ablation is the mainstay of therapy for supraventricular tachyarrhythmias. Conventional radiofrequency catheter ablation requires the use of fluoroscopy, thus exposing patients to ionising radiation. The feasibility and safety of non-fluoroscopic radiofrequency catheter ablation has been recently reported in a wide range of supraventricular tachyarrhythmias using the EnSite NavX™ mapping system. The NO-PARTY is a multi-centre, randomised controlled trial designed to test the hypothesis that catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system results in a clinically significant reduction in exposure to ionising radiation compared with conventional catheter ablation. The study will randomise 210 patients undergoing catheter ablation of supraventricular tachyarrhythmias to either a conventional ablation technique or one guided by the EnSite NavX™ mapping system. The primary end-point is the reduction of the radiation dose to the patient. Secondary end-points include procedural success, reduction of the radiation dose to the operator, and a cost-effectiveness analysis. In a subgroup of patients, we will also evaluate the radiobiological effectiveness of dose reduction by assessing acute chromosomal DNA damage in peripheral blood lymphocytes. NO-PARTY will determine whether radiofrequency catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system is a suitable and cost-effective approach to achieve a clinically significant reduction in ionising radiation exposure for both patient and operator.

  3. Randomized and controlled prospective trials of Ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment for lower back post-herpetic neuralgia.

    PubMed

    Pi, Z B; Lin, H; He, G D; Cai, Z; Xu, X Z

    2015-01-01

    To evaluate the efficacy of ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment for lower back post-herpetic neuralgia. 128 cases of lower back or anterior abdominal wall acute post-herpetic neuralgia patients were selected. They were randomly divided into two groups. Group A: oral treatment only with gabapentin + celecoxib + amitriptyline. Group B: while taking these drugs, patients were treated with radiofrequency (RF) pulses using a portable ultrasound device using the paravertebral puncture technique. In both groups, sudden outbreaks of pain were treated with immediate release 10mg morphine tablets. Visual analogue scale (VAS) was used for pain score, Pittsburgh Sleep Quality Index scale (PSQI) was used to evaluate sleep quality and morphine consumption were recorded at different time points, before and after treatment. Treatment efficiency was calculated while the occurrence of complications was documented. At each time point after treatment, VAS scores were lower, but scores in the RF group was significantly lower than those of the oral-only group. In terms of sleep quality scores and morphine consumption between the two groups, the RF group was significantly lower than the oral-only group. During the procedure no error occurred with needle penetrating the abdominal cavity, chest, offal or blood vessels. Ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment of lower back or anterior abdominal wall post-herpetic neuralgia proved effective by reducing morphine use in patients and led to fewer adverse reactions.

  4. Use of fluoroscopy-guided wire manipulation and/or laparoscopic surgery in the repair of malfunctioning peritoneal dialysis catheters.

    PubMed

    Kim, Hee Jin; Lee, Tae Won; Ihm, Chun Gyoo; Kim, Myung Jae

    2002-01-01

    Peritoneal catheter is the lifeline for the continuous ambulatory peritoneal dialysis (CAPD) patients. Over the years, obstruction or displacement of the CAPD catheter has been one of the common complications of CAPD. Fluoroscopy-guided wire manipulation or laparoscopic surgery has been developed to manage outflow obstruction. We analyzed the catheter outcome of fluoroscopy-guided wire manipulation or laparoscopic surgery to determine the ultimate benefit of these procedures. From June 1996 to August 2000, catheter complications were manipulated in 24 patients. Eleven (46%) of these patients were initially managed by guide wire under fluoroscopic control. The remaining 13 (54%) patients were manipulated by laparoscopic surgery. A successful outcome was defined as maintained normal peritoneal catheter function at 30 days after the manipulations. Among the catheters manipulated, 18 (75%) were inserted by nephrologist and 6 (25%) by surgeons at the initiation of CAPD. Tenckhoff double-cuff peritoneal catheters were inserted to all patients. The time elapsed between catheter insertion and manipulation varied from 1 to 60 days with a mean of 11 days. The primary causes of catheter malfunction were kinking in 1 case, omental wrapping with adhesions in 9 cases, and catheter displacements in the remaining 14 cases. Thirty-day catheter function was achieved in 50% (12/24) of initial catheter manipulations, with guide wire under fluoroscopic control (46%, 5/11) and laparoscopic surgery (54%, 7/13). Overall success rate of repeated manipulation was 71% (17 of 24). The successful outcome in repairing of the malfunctioning CAPD catheters could be increased by the combination of fluoroscopy-guided wire manipulation and laparoscopic surgery. Copyright 2002 S. Karger AG, Basel

  5. A cost-effective 25-Gb/s EML TOSA using all-in-one FPCB wiring and metal optical bench.

    PubMed

    Han, Young-Tak; Kwon, Oh-Kee; Lee, Dong-Hun; Lee, Chul-Wook; Leem, Young-Ahn; Shin, Jang-Uk; Park, Sang-Ho; Baek, Yongsoon

    2013-11-04

    We present a cost-effective 25-Gb/s electro-absorption modulator integrated laser (EML) transmitter optical sub-assembly (TOSA) using all-in-one flexible printed circuit board (FPCB) wiring and a metal optical bench (MOB). For a low cost and high bandwidth TOSA, internal and external wirings and feed-through of the TOSA to transmit radio-frequency (RF) signal are configured all-in-one using the FPCB. The FPCB is extended from an exterior of the TOSA package up to an EML chip inside the package through the slit formed on a rear sidewall of the package and die-bonded on the MOB. The EML TOSA shows a modulated output power of more than 3.5 dBm and a clear eye pattern with a dynamic extinction ratio of ~8.4 dB at a data rate of 25.78 Gb/s.

  6. Application of Ultrasonic Guided Waves for Evaluating Aging Wire Insulation

    NASA Technical Reports Server (NTRS)

    Anastasi, Robert F.; Madaras, Eric I.

    2005-01-01

    Aging wiring has become a critical issue to the aerospace and aircraft industries due to Shuttle and aircraft incidents. The problem is that over time the insulation on wire becomes brittle and cracks. This exposes the underlying conductive wire to the potential for short circuits and fire. Popular methods of monitoring aging wire problems focuses on applying electrical sensing techniques that are sensitive to the conductor's condition, but not very sensitive to the wire insulation's condition. Measurement of wire insulation stiffness and ultrasonic properties by ultrasonic guided waves is being examined. Experimental measurements showed that the lowest order extensional mode could be sensitive to stiffness changes in the wire insulation. To test this theory conventional wire samples were heat damaged in an oven, in a range of heating conditions. The samples were 12, 16, and 20 gauge and the heat damage introduced material changes in the wire insulation that made the originally flexible insulation brittle and darker in color. Results showed that extensional mode phase velocity increased for the samples that were exposed to heat for longer duration.

  7. Radiofrequency Energy and Electrode Proximity Influences Stereoelectroencephalography-Guided Radiofrequency Thermocoagulation Lesion Size: An In Vitro Study with Clinical Correlation.

    PubMed

    Staudt, Michael D; Maturu, Sarita; Miller, Jonathan P

    2018-02-16

    Radiofrequency thermocoagulation of epileptogenic foci via stereoelectroencephalography (SEEG) electrodes has been suggested as a treatment for medically intractable epilepsy, but reported outcomes have been suboptimal, possibly because lesions generated using conventional high-energy radiofrequency parameters are relatively small. To describe a technique of delivering low energy across separate SEEG electrodes in order to create large confluent radiofrequency lesions. The size and configuration of radiofrequency lesions using different radiofrequency intensity and interelectrode distance was assessed in egg whites. Magnetic resonance images (MRI) from 3 patients who had undergone radiofrequency lesion creation were evaluated to determine the contribution of lesion intensity and electrode separation on lesion size. Electroencephalography, MRI, and clinical data were assessed before and after lesion creation. Both in Vitro and in Vivo analysis revealed that less energy paradoxically produced larger lesions, with the largest possible lesions produced when radiofrequency power was applied for long duration at less than 3 W. Linear separation of electrodes also contributed to lesion size, with largest lesions produced when electrodes were separated by a linear distance of between 5 and 12 mm. Clinical lesions produced using these parameters were large and resulted in improvement in interictal and ictal activity. Radiofrequency lesions produced using low-energy delivery between SEEG electrodes in close proximity can produce a large lesion. These findings might have advantages for treatment of focal epilepsy.

  8. Electro-opto-mechanical radio-frequency oscillator driven by guided acoustic waves in standard single-mode fiber

    NASA Astrophysics Data System (ADS)

    London, Yosef; Diamandi, Hilel Hagai; Zadok, Avi

    2017-04-01

    An opto-electronic radio-frequency oscillator that is based on forward scattering by the guided acoustic modes of a standard single-mode optical fiber is proposed and demonstrated. An optical pump wave is used to stimulate narrowband, resonant guided acoustic modes, which introduce phase modulation to a co-propagating optical probe wave. The phase modulation is converted to an intensity signal at the output of a Sagnac interferometer loop. The intensity waveform is detected, amplified, and driven back to modulate the optical pump. Oscillations are achieved at a frequency of 319 MHz, which matches the resonance of the acoustic mode that provides the largest phase modulation of the probe wave. Oscillations at the frequencies of competing acoustic modes are suppressed by at least 40 dB. The linewidth of the acoustic resonance is sufficiently narrow to provide oscillations at a single longitudinal mode of the hybrid cavity. Competing longitudinal modes are suppressed by at least 38 dB as well. Unlike other opto-electronic oscillators, no radio-frequency filtering is required within the hybrid cavity. The frequency of oscillations is entirely determined by the fiber opto-mechanics.

  9. Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com; Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com

    ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioningmore » a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.« less

  10. Life-threatening hematuria requiring transcatheter embolization following radiofrequency ablation of renal cell carcinoma.

    PubMed

    Roach, H; Whittlestone, T; Callaway, M P

    2006-01-01

    Radiofrequency ablation is increasingly being acknowledged as a valid treatment for renal cell carcinoma in patients in whom definitive curative resection is deemed either undesirable or unsafe. A number of published series have shown the technique to have encouraging results and relatively low complication rates. In this article, we report a case of delayed life-threatening hematuria requiring transcatheter embolization of a bleeding intrarenal artery in a patient who had undergone imaging-guided radiofrequency ablation of a 3 cm renal cell carcinoma. To our knowledge, such a complication has not been reported previously.

  11. Vocational Preparation Curriculum: Electrical Wiring.

    ERIC Educational Resources Information Center

    Usoro, Hogan

    This document is a curriculum guide for instructors teaching vocational preparation for electrical wiring to special needs students. The purpose of the curriculum guide is to provide minimum skills for disadvantaged and handicapped students entering the mainstream; to supplement vocational skills of those students already in a regular training…

  12. Residential Wiring. Second Edition.

    ERIC Educational Resources Information Center

    Taylor, Mark; And Others

    This guide is designed to assist teachers conducting a course to prepare students for entry-level employment in the residential wiring trade. Included in the guide are six instructional units and the following sections of information for teachers: guidelines in using the unit components; academic and workplace skills classifications and…

  13. Commercial and Industrial Wiring. Second Edition.

    ERIC Educational Resources Information Center

    Kaltwasser, Stan; Flowers, Gary

    This guide is designed to assist teachers conducting a course to prepare students for entry-level employment in the commercial and industrial wiring trade. Included in the guide are 15 instructional units and the following sections of information for teachers: guidelines in using the unit components; academic and workplace skills classifications…

  14. Novel Percutaneous Radiofrequency Ablation of Portal Vein Tumor Thrombus: Safety and Feasibility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mizandari, Malkhaz; Ao, Guokun; Zhang Yaojun

    2013-02-15

    We report our experience of the safety of partial recanalization of the portal vein using a novel endovascular radiofrequency (RF) catheter for portal vein tumor thrombosis. Six patients with liver cancer and tumor thrombus in the portal vein underwent percutaneous intravascular radiofrequency ablation (RFA) using an endovascular bipolar RF device. A 0.035-inch guidewire was introduced into a tributary of the portal vein and through which a 5G guide catheter was introduced into the main portal vein. After manipulation of the guide catheter over the thrombus under digital subtraction angiography, the endovascular RF device was inserted and activated around the thrombus.more » There were no observed technique specific complications, such as hemorrhage, vessel perforation, or infection. Post-RFA portography showed partial recanalization of portal vein. RFA of portal vein tumor thrombus in patients with hepatocellular carcinoma is technically feasible and warrants further investigation to assess efficacy compared with current recanalization techniques.« less

  15. Experimental investigation of a metasurface resonator for in vivo imaging at 1.5 T

    NASA Astrophysics Data System (ADS)

    Shchelokova, Alena V.; Slobozhanyuk, Alexey P.; de Bruin, Paul; Zivkovic, Irena; Kallos, Efthymios; Belov, Pavel A.; Webb, Andrew

    2018-01-01

    In this work, we experimentally demonstrate an increase in the local transmit efficiency of a 1.5 T MRI scanner by using a metasurface formed by an array of brass wires embedded in a high permittivity low loss medium. Placement of such a structure inside the scanner results in strong coupling of the radiofrequency field produced by the body coil with the lowest frequency electromagnetic eigenmode of the metasurface. This leads to spatial redistribution of the near fields with enhancement of the local magnetic field and an increase in the transmit efficiency per square root maximum specific absorption rate in the region-of-interest. We have investigated this structure in vivo and achieved a factor of 3.3 enhancement in the local radiofrequency transmit efficiency.

  16. Analgesic Effect and Functional Improvement Caused by Radiofrequency Treatment of Genicular Nerves in Patients With Advanced Osteoarthritis of the Knee Until 1 Year Following Treatment.

    PubMed

    Santana Pineda, María M; Vanlinthout, Luc E; Moreno Martín, Ana; van Zundert, Jan; Rodriguez Huertas, Fernando; Novalbos Ruiz, José P

    Radiofrequency ablation of genicular nerves has proved to be successful in relieving pain and incapacity caused by osteoarthritis of the knee. However, long-term efficacy of such a treatment remains to be assessed. The current study aimed to reproduce radiofrequency neurotomy of genicular nerves to manage gonarthrosis pain and disability and establish therapeutic response until 1 year after intervention. This single-center, prospective, observational, noncontrolled, longitudinal study included patients with grade 3 to 4 gonarthrosis suffering from intractable knee pain, scoring 5 or more on the visual analog scale (VAS) during >6 months. Therapy was based on ultrasound guided radiofrequency neurotomy of the superior medial, superior lateral and inferior medial genicular nerves. Visual analog scale and Western Ontario and McMaster Universities Osteoarthritis scores were assessed before therapy and at 1, 6, and 12 months following treatment. Radiofrequency neurotomy of genicular nerves significantly reduced perceived pain (VAS) and disability (Western Ontario and McMaster Universities Osteoarthritis) in the majority of participants, without untoward events. The proportion of participants with improvement of 50% or greater in pretreatment VAS scores at 1, 6, and 12 months following intervention were 22/25 (88%), 16/25 (64%) and 8/25 (32%), respectively. Ultrasound-guided radiofrequency neurotomy of genicular nerves alleviates intractable pain and disability in the majority of patients with advanced osteoarthritis of the knee. Such a treatment is safe and minimally invasive and can be performed in an outpatient setting. The beneficial effect of treatment started to decline after 6 months, but even 1 year after the intervention, 32% of patients reported 50% improvement or greater in pretreatment VAS scores.

  17. Stereo-electro-encephalography-Guided Radiofrequency Thermocoagulation: From In Vitro and In Vivo Data to Technical Guidelines.

    PubMed

    Bourdillon, Pierre; Isnard, Jean; Catenoix, Hélène; Montavont, Alexandra; Rheims, Sylvain; Ryvlin, Philippe; Ostrowsky-Coste, Karine; Mauguiere, François; Guénot, Marc

    2016-10-01

    Deep brain electrodes have been used for the past 10 years to produce bipolar stereo-electro-encephalography-guided radiofrequency thermocoagulation (SEEG RF-TC). However, this technique is based on empiric knowledge. The aim of this study is 3-fold: 1) provide in vivo animal data concerning the effect of bipolar RF-TC on brain and its safety; 2) assess the parameters of this procedure (current delivery and dipole selection) that produce the most efficient lesion; and 3) provide technical guidelines. First we achieved in vivo RF-TC on rabbit brains with several conditions (power delivered and lesioning duration) and analyzed their influence on the lesion produced. Only a difference in terms of volume was found, and type of histologic lesions was similar whatever the settings were. We then performed multiple RF-TC in vitro on egg albumen, first with several parameters of radiofrequency and then with different dipole spatial selections. The end point was the size of the radiofrequency thermolesion produced. Using unfixed parameters of radiofrequency current delivery and increasing it until the power delivered by the generator collapsed produced significantly larger lesions (P = 0.008) than other conditions. Concerning the dipole selection, the use of contiguous contacts on electrodes led to lesions with a higher volume (P = 7.7 × 10 -13 ) than those produced with noncontiguous ones. Besides the target selection in SEEG RF-TC, which is summarized on the basis of a literature review, we report the optimal parameters: Radiofrequency current must be increased until the power delivered collapses, and dipoles should be constituted by contiguous electrode contacts. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Initial experience of EUS-guided radiofrequency ablation of unresectable pancreatic cancer.

    PubMed

    Song, Tae Jun; Seo, Dong Wan; Lakhtakia, Sundeep; Reddy, Nageshwar; Oh, Dong Wook; Park, Do Hyun; Lee, Sang Soo; Lee, Sung Koo; Kim, Myung-Hwan

    2016-02-01

    Radiofrequency ablation (RFA) has been used as a valuable treatment modality for various unresectable malignancies. EUS-guided radiofrequency ablation (EUS-RFA) of the porcine pancreas was reported to be feasible and safe in our previous study, suggesting that EUS-RFA may be applicable as an adjunct and effective alternative treatment method for unresectable pancreatic cancer. This study aimed to assess the technical feasibility and safety of EUS-RFA for unresectable pancreatic cancer. An 18-gauge endoscopic RFA electrode and a radiofrequency generator were used for the procedure. The length of the exposed tip of the RFA electrode was 10 mm. After insertion of the RFA electrode into the mass, the radiofrequency generator was activated to deliver 20 to 50 W ablation power for 10 seconds. Depending on tumor size, the procedure was repeated to sufficiently cover the tumor. EUS-RFA was performed successfully in all 6 patients (median age 62 years, range 43-73 years). Pancreatic cancer was located in the head (n = 4) or body (n = 2) of the pancreas. The median diameter of masses was 3.8 cm (range 3cm-9cm). Four patients had stage 3 disease, and 2 patients had stage 4 disease. After the procedure, 2 patients experienced mild abdominal pain, but there were no other adverse events such as pancreatitis or bleeding. EUS-RFA could be a technically feasible and safe option for patients with unresectable pancreatic cancer. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  19. Bending stiffness of catheters and guide wires.

    PubMed

    Wünsche, P; Werner, C; Bloss, P

    2002-01-01

    An important property of catheters and guide wires to assess their pushability behavior is their bending stiffness. To measure bending stiffness, a new bending module with a new clamping device was developed. This module can easily be mounted in commercially available tensile testing equipment, where bending force and deflection due to the bending force can be measured. To achieve high accuracy for the bending stiffness, the bending distance has to be measured with even higher accuracy by using a laser-scan micrometer. Measurement results of angiographic catheters and guide wires were presented and discussed. The bending stiffness shows a significant dependence on the angle of the test specimen's rotation around its length axis.

  20. Residential Wiring. Teacher Edition [and] Student Edition. Third Edition.

    ERIC Educational Resources Information Center

    Taylor, Mark; Batson, Larry; Carroll, Charles; Ipock, Dan; Leak, Lester; Onstott, Todd

    This revised curriculum guide for teachers and students is designed to help prepare students for entry-level employment in the residential wiring trade. The curriculum guide contains six units that cover the following topics: (1) blueprint reading and load calculations; (2) service; (3) rough-in; (4) trim out and troubleshooting; (5) low voltage…

  1. General Construction Trades. Volume 2. Teacher's Guide.

    ERIC Educational Resources Information Center

    East Texas State Univ., Commerce. Occupational Curriculum Lab.

    Twenty-one general construction units are presented in this teacher's guide. The units are organized as follow: concrete finishing-two units (e.g., site preparation, pouring and finishing); plumbing-five units (e.g., pipe joints, angles, and flow; fixtures and valves); electrical wiring-five units (e.g., wiring procedures, planning a layout);…

  2. Commercial and Industrial Wiring. Teacher Edition [and] Student Edition. Third Edition.

    ERIC Educational Resources Information Center

    Kaltwasser, Stan; Flowers, Gary; Aneke, Norbert O.

    This revised curriculum guide for teachers and students includes the additional technical knowledge and applications required to help prepare students for job entry in the commercial and industrial wiring trade. The curriculum guide contains 16 units that cover the following topics: (1) blueprint reading and load calculations; (2) tools and…

  3. Industrial Education. Electricity/Electronics Curriculum Guide, Phase II. Instructional Modules, Level I (9 Week).

    ERIC Educational Resources Information Center

    Lillo, Robert E.; Soffiotto, Nicholas S.

    Designed for students in grades 7 and 8, this electricity/electronics curriculum guide contains instructional modules for ten units of instruction (nine-week class): (1) orientation; (2) understanding electricity; (3) safety; (4) methods to generate electricity; (5) wiring tools and wire; (6) soldering; (7) magnetism and electromagnetism; (8)…

  4. Industrial Education. Electricity/Electronics Curriculum Guide, Phase II. Instructional Modules, Level I (18 Week).

    ERIC Educational Resources Information Center

    Lillo, Robert E.; Soffiotto, Nicholas S.

    Designed for students in grades 7 and 8, this electricity/electronics curriculum guide contains instructional modules for twelve units of instruction: (1) orientation; (2) understanding electricity; (3) safety; (4) methods to generate electricity; (5) wiring tools and wire; (6) soldering; (7) magnetism and electromagnetism; (8) circuits, symbols,…

  5. Perioperative ultrasound-guided wire marking of calcific deposits in calcifying tendinitis of the rotator cuff.

    PubMed

    Sigg, Andreas; Draws, Detlev; Stamm, Axel; Pfeiffer, Michael

    2011-03-01

    The identification of a calcific deposit in the rotator cuff can often cause difficulties. A new technique is described to identify the calcific deposit perioperatively with a ultrasound-guided wire. The technique allows a safe direct marking of calcific deposits making the procedure faster especially in difficult cases.

  6. Inductively guided circuits for ultracold dressed atoms

    PubMed Central

    Sinuco-León, German A.; Burrows, Kathryn A.; Arnold, Aidan S.; Garraway, Barry M.

    2014-01-01

    Recent progress in optics, atomic physics and material science has paved the way to study quantum effects in ultracold atomic alkali gases confined to non-trivial geometries. Multiply connected traps for cold atoms can be prepared by combining inhomogeneous distributions of DC and radio-frequency electromagnetic fields with optical fields that require complex systems for frequency control and stabilization. Here we propose a flexible and robust scheme that creates closed quasi-one-dimensional guides for ultracold atoms through the ‘dressing’ of hyperfine sublevels of the atomic ground state, where the dressing field is spatially modulated by inductive effects over a micro-engineered conducting loop. Remarkably, for commonly used atomic species (for example, 7Li and 87Rb), the guide operation relies entirely on controlling static and low-frequency fields in the regimes of radio-frequency and microwave frequencies. This novel trapping scheme can be implemented with current technology for micro-fabrication and electronic control. PMID:25348163

  7. Radiofrequency sensory ablation as a treatment for symptomatic unilateral lumbosacral junction pseudarticulation (Bertolotti's syndrome): a case report.

    PubMed

    Burnham, Robert

    2010-06-01

    Describe the clinical presentation, diagnostic evaluation, and successful treatment of a case of symptomatic unilateral lumbosacral junction pseudarticulation using a novel radiofrequency nerve ablation technique. A 56-year-old female patient who had suffered with low back and right upper buttock pain for 16 years experienced incomplete relief with L4/5 facet joint radiofrequency ablation. She was found to have an elongated right L5 transverse process that articulated with the sacral ala (Bertolotti's syndrome). Fluoroscopically guided local anesthetic/corticosteroid injection into the pseudarthrosis eliminated her residual right buttock pain for the duration of the local anesthetic only. Complete pain relief was achieved by injecting local anesthetic circumferentially around the posterior pseudarthrosis articular margin. Accordingly, bipolar radiofrequency strip thermal lesions were created at the same locations. Complete pain relief and full restoration of function was achieved for 16 months postprocedure. This case report describes a novel radiofrequency technique for treating symptomatic lumbosacral junction pseudarticulation that warrants further evaluation.

  8. MRI-guided Wire Localization Surgical Biopsy in an Adolescent Patient with a Difficult to Diagnose Case of Lymphoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, Scott M., E-mail: Thompson.scott@mayo.edu; Gorny, Krzysztof R.; Jondal, Danielle E.

    A 17-year-old previously healthy female presented with a progressive soft tissue infiltrative process involving the neck and thorax. Extensive diagnostic evaluation including multiple imaging, laboratory, and biopsy studies was nondiagnostic. Due to an urgent need to establish a diagnosis and several previous nondiagnostic biopsies, she was referred to interventional radiology for MRI-guided wire localization immediately prior to open surgical biopsy. Under general anesthesia, wires were placed in the areas of increased T2 signal within the bilateral splenius capitis muscles using intermittent MRI-guidance followed by immediate surgical biopsy down to the wires. Pathology confirmed the diagnosis of diffuse large B-cell lymphoma.

  9. A Hybrid Reality Radiation-free Simulator for Teaching Wire Navigation Skills

    PubMed Central

    Kho, Jenniefer Y.; Johns, Brian D.; Thomas, Geb. W.; Karam, Matthew D.; Marsh, J. Lawrence; Anderson, Donald D.

    2016-01-01

    Objectives Surgical simulation is an increasingly important method to facilitate the acquiring of surgical skills. Simulation can be helpful in developing hip fracture fixation skills because it is a common procedure for which performance can be objectively assessed (i.e., the tip-apex distance). The procedure requires fluoroscopic guidance to drill a wire along an osseous trajectory to a precise position within bone. The objective of this study was to assess the construct validity for a novel radiation-free simulator designed to teach wire navigation skills in hip fracture fixation. Methods Novices (N=30) with limited to no surgical experience in hip fracture fixation and experienced surgeons (N=10) participated. Participants drilled a guide wire in the center-center position of a synthetic femoral head in a hip fracture simulator, using electromagnetic sensors to track the guide wire position. Sensor data were gathered to generate fluoroscopic-like images of the hip and guide wire. Simulator performance of novice and experienced participants was compared to measure construct validity. Results The simulator was able to discriminate the accuracy in guide wire position between novices and experienced surgeons. Experienced surgeons achieved a more accurate tip-apex distance than novices (13 vs 23 mm, respectively, p=0.009). The magnitude of improvement on successive simulator attempts was dependent on level of expertise; tip-apex distance improved significantly in the novice group, while it was unchanged in the experienced group. Conclusions This hybrid reality, radiation-free hip fracture simulator, which combines real-world objects with computer-generated imagery demonstrates construct validity by distinguishing the performance of novices and experienced surgeons. There is a differential effect depending on level of experience, and it could be used as an effective training tool in novice surgeons. PMID:26165262

  10. Mountain Plains Learning Experience Guide: Electrical Wiring. Course: Electrical Wiring Rough-In.

    ERIC Educational Resources Information Center

    Arneson, R.; And Others

    One of two individualized courses included in an electrical wiring curriculum, this course covers electrical installations that are generally hidden within the structure. The course is comprised of four units: (1) Outlet and Switch Boxes, (2) Wiring, (3) Service Entrance, and (4) Signal and Low Voltage Systems. Each unit begins with a Unit…

  11. Experimental investigation of a metasurface resonator for in vivo imaging at 1.5 T.

    PubMed

    Shchelokova, Alena V; Slobozhanyuk, Alexey P; de Bruin, Paul; Zivkovic, Irena; Kallos, Efthymios; Belov, Pavel A; Webb, Andrew

    2018-01-01

    In this work, we experimentally demonstrate an increase in the local transmit efficiency of a 1.5 T MRI scanner by using a metasurface formed by an array of brass wires embedded in a high permittivity low loss medium. Placement of such a structure inside the scanner results in strong coupling of the radiofrequency field produced by the body coil with the lowest frequency electromagnetic eigenmode of the metasurface. This leads to spatial redistribution of the near fields with enhancement of the local magnetic field and an increase in the transmit efficiency per square root maximum specific absorption rate in the region-of-interest. We have investigated this structure in vivo and achieved a factor of 3.3 enhancement in the local radiofrequency transmit efficiency. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Electromagnetic Fields, Pulsed Radiofrequency Radiation, and Epigenetics: How Wireless Technologies May Affect Childhood Development.

    PubMed

    Sage, Cindy; Burgio, Ernesto

    2018-01-01

    Mobile phones and other wireless devices that produce electromagnetic fields (EMF) and pulsed radiofrequency radiation (RFR) are widely documented to cause potentially harmful health impacts that can be detrimental to young people. New epigenetic studies are profiled in this review to account for some neurodevelopmental and neurobehavioral changes due to exposure to wireless technologies. Symptoms of retarded memory, learning, cognition, attention, and behavioral problems have been reported in numerous studies and are similarly manifested in autism and attention deficit hyperactivity disorders, as a result of EMF and RFR exposures where both epigenetic drivers and genetic (DNA) damage are likely contributors. Technology benefits can be realized by adopting wired devices for education to avoid health risk and promote academic achievement. © 2017 The Authors. Child Development © 2017 Society for Research in Child Development, Inc.

  13. Results of Cryoenergy and Radiofrequency-Based Catheter Ablation for Treating Ventricular Arrhythmias Arising From the Papillary Muscles of the Left Ventricle, Guided by Intracardiac Echocardiography and Image Integration.

    PubMed

    Rivera, Santiago; Ricapito, Maria de la Paz; Tomas, Leandro; Parodi, Josefina; Bardera Molina, Guillermo; Banega, Rodrigo; Bueti, Pablo; Orosco, Agustin; Reinoso, Marcelo; Caro, Milagros; Belardi, Diego; Albina, Gaston; Giniger, Alberto; Scazzuso, Fernando

    2016-04-01

    Catheter radiofrequency ablation of ventricular arrhythmias (VAs) arising from the left ventricle's papillary muscles has been associated with inconsistent results. The use of cryoenergy versus radiofrequency has not been compared yet. This study compares outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either cryoenergy or radiofrequency. Twenty-one patients (40±12 years old; 47% males; median ejection fraction 59±7.3%) with drug refractory premature ventricular contractions or ventricular tachycardia underwent catheter cryoablation or radiofrequency ablation. VAs were localized using 3-dimensional mapping, multidetector computed tomography, and intracardiac echocardiography, with arrhythmia foci being mapped at either the anterolateral papillary muscle or posteromedial papillary muscles of the left ventricle. Focal ablation was performed using an 8-mm cryoablation catheter or a 4-mm open-irrigated radiofrequency catheter, via transmitral approach. Acute success rate was 100% for cryoenergy (n=12) and 78% for radiofrequency (n=9; P=0.08). Catheter stability was achieved in all patients (100%) treated with cryoenergy, and only in 2 (25%) patients treated with radiofrequency (P=0.001). Incidence of multiple VA morphologies was observed in 7 patients treated with radiofrequency (77.7%), whereas none was observed in those treated with cryoenergy (P=0.001). VA recurrence at 6 months follow-up was 0% for cryoablation and 44% for radiofrequency (P=0.03). Cryoablation was associated with higher success rates and lower recurrence rates than radiofrequency catheter ablation, better catheter stability, and lesser incidence of polymorphic arrhythmias. © 2016 American Heart Association, Inc.

  14. Application of active quenching of second generation wire for current limiting

    DOE PAGES

    Solovyov, Vyacheslav F.; Li, Qiang

    2015-10-19

    Superconducting fault current limiters (SFCL's) are increasingly implemented in the power grid as a protection of substation equipment from fault currents. Resistive SFCL's are compact and light, however they are passively triggered and thus may not be sufficiently sensitive to respond to faults in the distribution grid. Here, we explore the prospect of adding an active management feature to a traditional resistive SFCL. A flexible radio-frequency coil, which is an integral part of the switching structure, acts as a triggering device. We show that the application of a short, 10 ms, burst of ac magnetic field during the fault triggersmore » a uniform quench of the wire and significantly reduces the reaction time of the wire at low currents. The ac field burst generates a high density of normal zones, which merge into a continuous resistive region at a rate much faster than that of sparse normal zones created by the transport current alone.« less

  15. Electromagnetic Tracking Navigation to Guide Radiofrequency Ablation (RFA) of a Lung Tumor

    PubMed Central

    Amalou, Hayet; Wood, Bradford J.

    2013-01-01

    Radiofrequency ablation (RFA) may be an option for patients with lung tumors who have unresectable disease and are not suitable for available palliative modalities. RFA electrode positioning may take several attempts, necessitating multiple imaging acquisitions or continuous use of CT (Computed Tomography). Electromagnetic tracking utilizes miniature sensors integrated with RFA equipment to guide tools in real-time, while referencing to pre-procedure imaging. This technology was demonstrated successfully during a lung tumor ablation, and was more accurate at targeting the tumor, compared to traditional freehand needle insertion. It is possible, although speculative and anecdotal, that more accuracy could prevent unnecessary repositioning punctures and decrease radiation exposure. Electromagnetic tracking has theoretical potential to benefit minimally invasive interventions. PMID:23207535

  16. Percutaneous CT-guided radiofrequency ablation of renal cell carcinoma: efficacy of organ displacement by injection of 5% dextrose in water into the retroperitoneum.

    PubMed

    Arellano, Ronald S; Garcia, Rodrigo G; Gervais, Debra A; Mueller, Peter R

    2009-12-01

    The objective of this study was to evaluate the effectiveness of CT-guided injection of 5% dextrose in water solution (D5W) into the retroperitoneum to displace organs adjacent to renal cell carcinoma. An interventional radiology database was searched to identify the cases of patients who underwent CT-guided percutaneous radiofrequency ablation of biopsy-proven renal cell carcinoma in which D5W was injected into the retroperitoneal space to displace structures away from the targeted renal tumor. The number of organs displaced and the distance between the renal tumor and adjacent organs before and after displacement with D5W were assessed. The cases of 135 patients with 139 biopsy-proven renal cell carcinomas who underwent 154 percutaneous CT-guided radiofrequency ablation procedures were found in the search. Thirty-one patients with 33 renal cell carcinomas underwent 36 ablation procedures after injection of D5W into the retroperitoneal space. Fifty-five organs were displaced away from renal cell carcinoma with this technique. The average distance between adjacent structures and renal cell carcinomas before displacement was 0.36 cm (range, 0.1-1.0 cm). The average distance between structures and adjacent renal cell carcinomas after displacement was 1.94 cm (range, 1.1-4.3 cm) (p < 0.0001). The average volume of D5W used to achieve organ displacement was 273.5 mL. No complications were associated with this technique. CT-guided injection of D5W into the retroperitoneum is an effective method for displacing vital structures away from renal cell carcinoma.

  17. High-performance radio frequency transistors based on diameter-separated semiconducting carbon nanotubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cao, Yu; Che, Yuchi; Zhou, Chongwu, E-mail: chongwuz@usc.edu

    In this paper, we report the high-performance radio-frequency transistors based on the single-walled semiconducting carbon nanotubes with a refined average diameter of ∼1.6 nm. These diameter-separated carbon nanotube transistors show excellent transconductance of 55 μS/μm and desirable drain current saturation with an output resistance of ∼100 KΩ μm. An exceptional radio-frequency performance is also achieved with current gain and power gain cut-off frequencies of 23 GHz and 20 GHz (extrinsic) and 65 GHz and 35 GHz (intrinsic), respectively. These radio-frequency metrics are among the highest reported for the carbon nanotube thin-film transistors. This study provides demonstration of radio frequency transistors based on carbon nanotubes with tailoredmore » diameter distributions, which will guide the future application of carbon nanotubes in radio-frequency electronics.« less

  18. A Kirschner wire as a transverse-axis guide to improve acetabular cup positioning.

    PubMed

    Ishidou, Y; Hirotsu, M; Setoguchi, T; Nagano, S; Kakoi, H; Yokouchi, M; Yamamoto, T; Komiya, S

    2016-04-01

    To compare cup-positioning accuracy in total hip arthroplasty (THA) with or without use of a Kirschner wire as a transverse-axis guide for pelvic alignment. Records of 18 men and 73 women (mean age, 60 years) who underwent primary THA with (n=49) or without (n=42) use of a Kirschner wire as a transverse-axis guide for pelvic alignment were reviewed. A 2.4-mm Kirschner wire as a transversea-xis guide was inserted to the anterior superior iliac spine and was parallel to a line linking the left and right anterior superior iliac spine. The safe zone for cup positioning was defined as 30º to 50° abduction and 10º to 30º anteversion. Of the 5 operative surgeons, 2 were classified as experienced (total surgical volume >300) and 3 as inexperienced (total surgical volume of <50). The proportion of patients with the cup in the safe zone was compared in patients with or without use of the transverse-axis guide and in experienced and inexperienced surgeons. For inexperienced surgeons, the use of the transverse-axis guide significantly improved the proportion of patients with the cup in the safe zone from 90% to 100% for abduction, from 50% to 82.4% for anteversion, and from 40% to 82.4% for both. Patients with the cup inside or outside the safe zone were comparable in terms of body height, weight, BMI, subcutaneous fat thickness, incision length, and acetabular cup size. The use of the transverse-axis guide improved the accuracy of cup positioning by inexperienced surgeons.

  19. Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures

    PubMed Central

    Chu, James C.H.; Hsi, Wen Chien; Hubbard, Lincoln; Zhang, Yunkai; Bernard, Damian; Reeder, Pamela; Lopes, Demetrius

    2005-01-01

    A hospital‐based magnetic guidance system (MGS) was installed to assist a physician in navigating catheters and guide wires during interventional cardiac and neurosurgical procedures. The objective of this study is to examine the performance of this magnetic field‐guided navigation system. Our results show that the system's radiological imaging components produce images with quality similar to that produced by other modern fluoroscopic devices. The system's magnetic navigation components also deflect the wire and catheter tips toward the intended direction. The physician, however, will have to oversteer the wire or catheter when defining the steering angle during the procedure. The MGS could be clinically useful in device navigation deflection and vessel access. PACS numbers: 07.55.Db, 07.85.‐m PMID:16143799

  20. MR-guided radiofrequency ablation of hepatic malignancies at 1.5 T: initial results.

    PubMed

    Mahnken, Andreas H; Buecker, Arno; Spuentrup, Elmar; Krombach, Gabriele A; Henzler, Dietrich; Günther, Rolf W; Tacke, Josef

    2004-03-01

    To assess the feasibility of magnetic resonance (MR)-guided radiofrequency ablation (RFA) of hepatic malignancies using a high-field MR scanner. A total of 10 patients with 14 primary (N = 1) or secondary (N = 13) hepatic malignancies underwent MR-guided RFA using a closed-bore 1.5 T MR scanner. Lesion diameters ranged from 2.0 cm to 4.7 cm. RFA was performed using a 200-W generator in combination with a 3.5-cm LeVeen electrode applying a standardized energy protocol. RFA was technically feasible in all patients. Necrosis diameter ranged from 2.5 cm to 6.8 cm. The mean follow-up period is 12.2 (1-18) months. In nine out of 10 patients, local tumor control was achieved. For this purpose, a second CT-guided RFA was required in two patients. In four patients, multifocal hepatic tumor progression occurred, with the treated lesion remaining tumor-free in three of these patients. Two patients showed extrahepatic tumor progression. Four patients remained tumor-free. No major complications occurred. MR-guided RFA of hepatic malignancies in a closed-bore high-field MR scanner is technically feasible and safe. It can be advantageous in locations considered unfavorable for CT-guided puncture or in patients in which iodinated contrast material is contraindicated. Copyright 2004 Wiley-Liss, Inc.

  1. ANALYSIS OF FACTORS AFFECTING OUTCOME OF ULTRASOUND-GUIDED RADIOFREQUENCY HEAT ABLATION FOR TREATMENT OF PRIMARY HYPERPARATHYROIDISM IN DOGS.

    PubMed

    Bucy, Daniel; Pollard, Rachel; Nelson, Richard

    2017-01-01

    Radiofrequency (RF) parathyroid ablation is a noninvasive treatment for hyperparathyroidism in dogs. There are no published data assessing factors associated with RF parathyroid ablation success or failure in order to guide patient selection and improve outcome. The purpose of this retrospective analytical study was to determine whether imaging findings, biochemical data, or concurrent diseases were associated with RF heat ablation treatment failure. For inclusion in the study, dogs must have had a clinical diagnosis of primary hyperparathyroidism, undergone cervical ultrasound and RF ablation of abnormal parathyroid tissue, and must have had at least 3 months of follow-up information available following the date of ultrasound-guided parathyroid ablation. Dogs were grouped based on those with recurrent or persistent hypercalcemia and those without recurrent or persistent hypercalcemia following therapy. Parathyroid nodule size, thyroid lobe size, nodule location, and presence of concurrent disease were recorded. Recurrence of hypercalcemia occurred in 9/32 dogs that had ablation of abnormal parathyroid tissue (28%) and one patient had persistent hypercalcemia (3%) following parathyroid ablation. Nodule width (P = 0.036), height (P = 0.028), and largest cross-sectional area (P = 0.023) were larger in dogs that had recurrent or persistent hypercalcemia following ablation. Hypothyroidism was more common in dogs with recurrent disease (P = 0.044). Radiofrequency ablation was successful in 22/32 (69%) dogs. Larger parathyroid nodule size and/or concurrent hypothyroidism were associated with treatment failure in dogs that underwent ultrasound-guided RF parathyroid nodule ablation. © 2016 American College of Veterinary Radiology.

  2. Renal Tumors: Technical Success and Early Clinical Experience with Radiofrequency Ablation of 18 Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sabharwal, Rohan, E-mail: rohan50000@yahoo.com; Vladica, Philip

    2006-04-15

    Purpose. To evaluate the feasibility, safety, and technical efficacy of image-guided radiofrequency ablation (RFA) for the treatment of small peripheral renal tumors and to report our early results with this treatment modality. Methods. Twenty-two RFA sessions for 18 tumors were performed in 11 patients with renal tumors. Indications included coexistent morbidity, high surgical or anesthetic risk, solitary kidney, and hereditary predisposition to renal cell carcinoma. Ten patients had CT-guided percutaneous RFA performed on an outpatient basis. One patient had open intraoperative ultrasound-guided RFA. Technical success was defined as elimination of areas that enhanced at imaging within the entire tumor. Withmore » the exception of one patient with renal insufficiency who required gadolinium-enhanced MRI, the remaining patients underwent contrast-enhanced CT for post-treatment follow-up assessment. Follow-up was performed after 2-4 weeks and then at 3, 6, 12 months, and every 12 months thereafter. Results. Fourteen (78%) of 18 tumors were successfully ablated with one session. Three of the remaining four tumors required two sessions for successful ablation. One tumor will require a third session for areas of persistent enhancement. Mean patient age was 72.82 {+-} 10.43 years. Mean tumor size was 1.95 {+-} 0.79 cm. Mean follow-up time was 10.91 months. All procedures were performed without any major complications. Conclusions. Our early experience with percutaneous image-guided radiofrequency ablation demonstrates it to be a feasible, safe, noninvasive, and effective treatment of small peripheral renal tumors.« less

  3. Comparison Between CT and MR Images as More Favorable Reference Data Sets for Fusion Imaging-Guided Radiofrequency Ablation or Biopsy of Hepatic Lesions: A Prospective Study with Focus on Patient's Respiration.

    PubMed

    Cha, Dong Ik; Lee, Min Woo; Kang, Tae Wook; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Kim, Kyunga

    2017-10-01

    To identify the more accurate reference data sets for fusion imaging-guided radiofrequency ablation or biopsy of hepatic lesions between computed tomography (CT) and magnetic resonance (MR) images. This study was approved by the institutional review board, and written informed consent was received from all patients. Twelve consecutive patients who were referred to assess the feasibility of radiofrequency ablation or biopsy were enrolled. Automatic registration using CT and MR images was performed in each patient. Registration errors during optimal and opposite respiratory phases, time required for image fusion and number of point locks used were compared using the Wilcoxon signed-rank test. The registration errors during optimal respiratory phase were not significantly different between image fusion using CT and MR images as reference data sets (p = 0.969). During opposite respiratory phase, the registration error was smaller with MR images than CT (p = 0.028). The time and the number of points locks needed for complete image fusion were not significantly different between CT and MR images (p = 0.328 and p = 0.317, respectively). MR images would be more suitable as the reference data set for fusion imaging-guided procedures of focal hepatic lesions than CT images.

  4. Reoperation Rates in Ductal Carcinoma In Situ vs Invasive Breast Cancer After Wire-Guided Breast-Conserving Surgery.

    PubMed

    Langhans, Linnea; Jensen, Maj-Britt; Talman, Maj-Lis M; Vejborg, Ilse; Kroman, Niels; Tvedskov, Tove F

    2017-04-01

    New techniques for preoperative localization of nonpalpable breast lesions may decrease the reoperation rate in breast-conserving surgery (BCS) compared with rates after surgery with the standard wire-guided localization. However, a valid reoperation rate for this procedure needs to be established for comparison, as previous studies on this procedure include a variety of malignant and benign breast lesions. To determine the reoperation rate after wire-guided BCS in patients with histologically verified nonpalpable invasive breast cancer (IBC) or ductal carcinoma in situ (DCIS) and to examine whether the risk of reoperation is associated with DCIS or histologic type of the IBC. This nationwide study including women with histologically verified IBC or DCIS having wire-guided BCS performed between January 1, 2010, and December 31, 2013, used data from the Danish National Patient Registry that were cross-checked with the Danish Breast Cancer Group database and the Danish Pathology Register. Reoperation rate after wire-guided BCS in patients with IBC or DCIS. Wire-guided BCS was performed in 4118 women (mean [SD] age, 60.9 [8.7] years). A total of 725 patients (17.6%) underwent a reoperation: 593 were reexcisions (14.4%) and 132 were mastectomies (3.2%). Significantly more patients with DCIS (271 of 727 [37.3%]) than with IBC (454 of 3391 [13.4%]) underwent a reoperation (adjusted odds ratio, 3.82; 95% CI, 3.19-4.58; P < .001). After the first reexcision, positive margins were still present in 97 patients (16.4%). The risk of repeated positive margins was significantly higher in patients with DCIS vs those with IBC (unadjusted odds ratio, 2.21; 95% CI, 1.42-3.43; P < .001). The risk of reoperation was significantly increased in patients with lobular carcinoma vs those with ductal carcinoma (adjusted odds ratio, 1.44; 95% CI 1.06-1.95; P = .02). A total of 202 patients (4.9%) had a subsequent completion mastectomy, but no difference was found in the type of reoperation between patients with DCIS and those with IBC. A lower reoperation rate after wire-guided BCS was found in this study than those shown in previous studies. However, the risk of reoperation in patients with DCIS was 3 times higher than in those with IBC. The widespread use of mammographic screening will increase the number of patients diagnosed with DCIS, making a precise localization of nonpalpable DCIS lesions even more important.

  5. Leading the Wired Organization: The Information Professional's Guide to Managing Technological Change.

    ERIC Educational Resources Information Center

    Stover, Mark

    This book explains through descriptive narrative, illustrative examples, and practical suggestions how today's information specialists can navigate in the new "wired" organizations. The emphasis is on practical, useful, relevant advice. The following ten chapters are included: (1) "Communicating Online: The Heart of the Wired Organization"…

  6. Basic Electricity. Part 4.

    ERIC Educational Resources Information Center

    Kilmer, Donald C.

    Designed for the student interested in a vocation in electrical work, this guide, fourth in a set of four, includes three units: Unit X--Splicing Wires, covering thirteen lessons (removing insulation, pigtail splice, Western Union splice, tap splice, extension cord splice, connecting wires to a terminal screw, underwriter's knot, three-wire ground…

  7. Pressure-wire-guided percutaneous transluminal pulmonary angioplasty: a breakthrough in catheter-interventional therapy for chronic thromboembolic pulmonary hypertension.

    PubMed

    Inami, Takumi; Kataoka, Masaharu; Shimura, Nobuhiko; Ishiguro, Haruhisa; Yanagisawa, Ryoji; Fukuda, Keiichi; Yoshino, Hideaki; Satoh, Toru

    2014-11-01

    This study sought to prove the safety and effectiveness of pressure-wire-guided percutaneous transluminal pulmonary angioplasty (PTPA). PTPA has been demonstrated to be effective for treatment of chronic thromboembolic pulmonary hypertension. However, a major and occasionally fatal complication after PTPA is reperfusion pulmonary edema. To avoid this, we developed the PEPSI (Pulmonary Edema Predictive Scoring Index). The pressure wire has been used to detect insufficiency of flow in a vessel. We included 350 consecutive PTPA sessions in 103 patients with chronic thromboembolic pulmonary hypertension from January 1, 2009 to December 31, 2013. During these 5 years, 140 PTPA sessions were performed without guidance, 65 with guidance of PEPSI alone, and 145 with both PEPSI and pressure-wire guidance. Each PTPA session was finished after achieving PEPSI scores of <35.4 with PEPSI guidance and each target lesion achieving distal mean pulmonary arterial pressure <35 mm Hg with pressure-wire guidance. The occurrence of clinically critical reperfusion pulmonary edema and vessel injuries were lowest in the group using the guidance of both pressure wire and PEPSI (0% and 6.9%, respectively). Furthermore, the group guided by pressure wire and PEPSI accomplished the same hemodynamic improvements with fewer numbers of target lesions treated and sessions performed. The combined approach using pressure wire and PEPSI produced more efficient clinical results and greatly reduced reperfusion pulmonary edema and vessel complications. This is further evidence that PTPA is an alternative strategy for treating chronic thromboembolic pulmonary hypertension. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Image-Guided Radiofrequency Ablation (RFA) of Unresectable Hepatic Tumors Using a Triple-Spiral-Shaped Electrode Needle: Initial Experience in 34 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thanos, Loukas; Poulou, Loukia S., E-mail: ploukia@hotmail.co; Ziakas, Panayiotis D.

    We evaluated the safety and efficacy of image-guided radiofrequency ablation (RFA) using a triple-spiral-shaped electrode needle for unresectable primary or metastatic hepatic tumors. Thirty-four patients with 46 index tumors were treated. Ablation zone, morbidity, and complications were assessed. The lesions were completely ablated with an ablative margin of about 1 cm. Five patients (14.7%) with a lesion larger than 4.5 cm had local tumor progression after 1 month and were retreated. Hemothorax, as a major complication, occurred in 1 of 34 patients (3.0%) or 1 of 46 lesions ablated (2.2%). RFA using this new electrode needle can be effective inmore » the treatment of large unresectable hepatic tumors.« less

  9. Image-Guided Spinal Ablation: A Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsoumakidou, Georgia, E-mail: gtsoumakidou@yahoo.com; Koch, Guillaume, E-mail: guillaume.koch@chru-strasbourg.fr; Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr

    2016-09-15

    The image-guided thermal ablation procedures can be used to treat a variety of benign and malignant spinal tumours. Small size osteoid osteoma can be treated with laser or radiofrequency. Larger tumours (osteoblastoma, aneurysmal bone cyst and metastasis) can be addressed with radiofrequency or cryoablation. Results on the literature of spinal microwave ablation are scarce, and thus it should be used with caution. A distinct advantage of cryoablation is the ability to monitor the ice-ball by intermittent CT or MRI. The different thermal insulation, temperature and electrophysiological monitoring techniques should be applied. Cautious pre-procedural planning and intermittent intra-procedural monitoring of themore » ablation zone can help reduce neural complications. Tumour histology, patient clinical-functional status and life-expectancy should define the most efficient and least disabling treatment option.« less

  10. Alternating current circuit theory and pulsed NMR (Nuclear Magnetic Resonance)

    NASA Astrophysics Data System (ADS)

    Gerstein, B. C.

    1987-06-01

    Pulsed NMR, by definition, deals with time varying excitations. These excitations, supplied by resonant circuits which provide a pulse of radiofrequency (frequencies in the megahertz region) power to a resonant circuit containing, among other things, a coil of wire, or inductor, in which a sample under investigation is placed for purposes of the nuclear magnetic resonance experiment. There are therefore two features of the pulse NMR experiment. First is the fact that we have available a source of continuous wave (CW) alternating current at some angular frequency, omega, measured in radians per second. This source is generally supplied by an ultrastable device called a frequency synthesizer. The second feature of the pulsed NMR experiment is that the sample is not continuously irradiated, but a pulse of radiofrequency oscillation is applied to the sample. This report discusses alternating current theory, resonant circuits and the equipment used in this experiment.

  11. Treatment of Refractory Idiopathic Supraorbital Neuralgia Using Percutaneous Pulsed Radiofrequency.

    PubMed

    Luo, Fang; Lu, Jingjing; Ji, Nan

    2018-02-26

    No ideal therapeutic method currently exists for refractory idiopathic supraorbital neuralgia patients who do not respond to conservative therapy, including medications and nerve blocks. Pulsed radiofrequency is a neuromodulation technique that does not produce sequelae of nerve damage after treatment. However, the efficacy of percutaneous pulsed radiofrequency for the treatment of refractory idiopathic supraorbital neuralgia is still not clear. The purpose of our study was to evaluate the efficacy and safety of pulsed radiofrequency treatment of the supraorbital nerve for refractory supraorbital neuralgia patients. We prospectively investigated the long-term effects of ultrasound-guided percutaneous pulsed radiofrequency in the treatment of 22 refractory idiopathic supraorbital neuralgia patients. A reduction in the verbal pain numeric rating scale score of more than 50% was used as the standard of effectiveness. The effectiveness rates at different time points within 2 years were calculated. After a single pulsed radiofrequency treatment, the effectiveness rate at 1 and 3 months was 77%, and the rates at 6 months, 1 year, and 2 years were 73%, 64%, and 50%, respectively. Except for a small portion of patients (23%) who experienced mild upper eyelid ecchymosis that gradually disappeared after approximately 2 weeks, no obvious complications were observed. In conclusion, the results of our study demonstrate that for patients with refractory idiopathic supraorbital neuralgia, percutaneous pulsed radiofrequency may be an effective and safe treatment choice. © 2018 World Institute of Pain.

  12. Percutaneous Radiofrequency Ablation of Lung Tumors in Contact with the Aorta: Dangerous and Difficult but Efficient: A Report of Two Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thanos, Loukas, E-mail: loutharad@yahoo.co; Mylona, Sofia; Giannoulakos, Nikolaos

    Percutaneous imaging-guided tumor ablation is a widely accepted method for the treatment of primary and secondary lung tumors. Although it is generally feasible and effective for local tumor control, some conditions may affect its feasibility and effectiveness. Herein the authors report their experience with two patients with lung malignancies contiguous to the aorta who were successfully treated with radiofrequency ablation, even though it initially appeared highly risky due to the possible fatal complications.

  13. CT fluoroscopy-guided preoperative short hook wire placement for small pulmonary lesions: evaluation of safety and identification of risk factors for pneumothorax.

    PubMed

    Iguchi, Toshihiro; Hiraki, Takao; Gobara, Hideo; Fujiwara, Hiroyasu; Matsui, Yusuke; Miyoshi, Shinichiro; Kanazawa, Susumu

    2016-01-01

    To retrospectively evaluate the safety of computed tomography (CT) fluoroscopy-guided short hook wire placement for video-assisted thoracoscopic surgery and the risk factors for pneumothorax associated with this procedure. We analyzed 267 short hook wire placements for 267 pulmonary lesions (mean diameter, 9.9 mm). Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for pneumothorax. Complications (219 grade 1 and 4 grade 2 adverse events) occurred in 196 procedures. No grade 3 or above adverse events were observed. Univariate analysis revealed increased vital capacity (odds ratio [OR], 1.518; P = 0.021), lower lobe lesion (OR, 2.343; P =0.001), solid lesion (OR, 1.845; P = 0.014), prone positioning (OR, 1.793; P = 0.021), transfissural approach (OR, 11.941; P = 0.017), and longer procedure time (OR, 1.036; P = 0.038) were significant predictors of pneumothorax. Multivariate analysis revealed only the transfissural approach (OR, 12.171; P = 0.018) and a longer procedure time (OR, 1.048; P = 0.012) as significant independent predictors. Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occurred, but all complications were minor. A transfissural approach and longer procedure time were significant independent predictors of pneumothorax. Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occur. Complications are usually minor and asymptomatic. A transfissural approach and longer procedure time are significant independent predictors of pneumothorax.

  14. A haptic device for guide wire in interventional radiology procedures.

    PubMed

    Moix, Thomas; Ilic, Dejan; Bleuler, Hannes; Zoethout, Jurjen

    2006-01-01

    Interventional Radiology (IR) is a minimally invasive procedure where thin tubular instruments, guide wires and catheters, are steered through the patient's vascular system under X-ray imaging. In order to perform these procedures, a radiologist has to be trained to master hand-eye coordination, instrument manipulation and procedure protocols. The existing simulation systems all have major drawbacks: the use of modified instruments, unrealistic insertion lengths, high inertia of the haptic device that creates a noticeably degraded dynamic behavior or excessive friction that is not properly compensated for. In this paper we propose a quality training environment dedicated to IR. The system is composed of a virtual reality (VR) simulation of the patient's anatomy linked to a robotic interface providing haptic force feedback. This paper focuses on the requirements, design and prototyping of a specific haptic interface for guide wires.

  15. The impact of wire caliber on ERCP outcomes: a multicenter randomized controlled trial of 0.025-inch and 0.035-inch guidewires.

    PubMed

    Bassan, Milan S; Sundaralingam, Praka; Fanning, Scott B; Lau, James; Menon, Jayaram; Ong, Evan; Rerknimitr, Rungsun; Seo, Dong-Wan; Teo, Eng Kiong; Wang, Hsiu-Po; Reddy, D Nageshwar; Goh, Khean Lee; Bourke, Michael J

    2018-06-01

    Wire-guided biliary cannulation has been demonstrated to improve cannulation rates and reduce post-ERCP pancreatitis (PEP), but the impact of wire caliber has not been studied. This study compares successful cannulation rates and ERCP adverse events by using a 0.025-inch and 0.035-inch guidewire. A randomized, single blinded, prospective, multicenter trial at 9 high-volume tertiary-care referral centers in the Asia-Pacific region was performed. Patients with an intact papilla and conventional anatomy who did not have malignancy in the head of the pancreas or ampulla and were undergoing ERCP were recruited. ERCP was performed by using a standardized cannulation algorithm, and patients were randomized to either a 0.025-inch or 0.035-inch guidewire. The primary outcomes of the study were successful wire-guided cannulation and the incidence of PEP. Overall successful cannulation and ERCP adverse events also were studied. A total of 710 patients were enrolled in the study. The primary wire-guided biliary cannulation rate was similar in 0.025-inch and 0.035-inch wire groups (80.7% vs 80.3%; P = .90). The rate of PEP between the 0.025-inch and the 0.035-inch wire groups did not differ significantly (7.8% vs 9.3%; P = .51). No differences were noted in secondary outcomes. Similar rates of successful cannulation and PEP were demonstrated in the use of 0.025-inch and 0.035-inch guidewires. (Clinical trial registration number: NCT01408264.). Copyright © 2018. Published by Elsevier Inc.

  16. Investigation of the interwire energy transfer of elastic guided waves inside prestressed cables.

    PubMed

    Treyssède, Fabien

    2016-07-01

    Elastic guided waves are of interest for the non-destructive evaluation of cables. Cables are most often multi-wire structures, and understanding wave propagation requires numerical models accounting for the helical geometry of individual wires, the interwire contact mechanisms and the effects of prestress. In this paper, a modal approach based on a so-called semi-analytical finite element method and taking advantage of a biorthogonality relation is proposed in order to calculate the forced response under excitation of a cable, multi-wired, twisted, and prestressed. The main goal of this paper is to investigate how the energy transfers from a given wire, directly excited, to the other wires in order to identify some localization of energy inside the active wire as the waves propagate along the waveguide. The power flow of the excited field is theoretically derived and an energy transfer parameter is proposed to evaluate the level of energy localization inside a given wire. Numerical results obtained for different polarizations of excitation, central and peripheral, highlight how the energy may localize, spread, or strongly change in the cross-section as waves travel along the axis. In particular, a compressional mode localized inside the central wire is found, with little dispersion and significant excitability.

  17. Entrapment of guide-wire during oesophageal dilation.

    PubMed

    Misra, S P; Dwivedi, M

    1997-01-01

    We report a patient who developed oesophageal stricture after accidental ingestion of acid. During one of the oesophageal dilation sessions, a Savary-Gillard guide-wire got entrapped in the stomach and had to be removed surgically. A Foley catheter, placed for feeding purposes, migrated into the proximal small intestine causing acute intestinal obstruction. The balloon of the Foley catheter had to be punctured using a sclerotherapy needle and the catheter withdrawn.

  18. PPM-based System for Guided Waves Communication Through Corrosion Resistant Multi-wire Cables

    NASA Astrophysics Data System (ADS)

    Trane, G.; Mijarez, R.; Guevara, R.; Pascacio, D.

    Novel wireless communication channels are a necessity in applications surrounded by harsh environments, for instance down-hole oil reservoirs. Traditional radio frequency (RF) communication schemes are not capable of transmitting signals through metal enclosures surrounded by corrosive gases and liquids. As an alternative to RF, a pulse position modulation (PPM) guided waves communication system has been developed and evaluated using a corrosion resistant 4H18 multi-wire cable, commonly used to descend electronic gauges in down-hole oil applications, as the communication medium. The system consists of a transmitter and a receiver that utilizes a PZT crystal, for electrical/mechanical coupling, attached to each extreme of the multi-wire cable. The modulator is based on a microcontroller, which transmits60 kHz guided wave pulses, and the demodulator is based on a commercial digital signal processor (DSP) module that performs real time DSP algorithms. Experimental results are presented, which were obtained using a 1m corrosion resistant 4H18multi-wire cable, commonly used with downhole electronic gauges in the oil sector. Although there was significant dispersion and multiple mode excitations of the transmitted guided wave energy pulses, the results show that data rates on the order of 500 bits per second are readily available employing PPM and simple communications techniques.

  19. Qureshi-5 Catheter for Complex Supra- and Abdominal-Aortic Catheterization

    PubMed Central

    Qureshi, Adnan I.; Xiao, WeiGang; Liu, HongLiang

    2015-01-01

    Background The use of previously described catheter technique was expanded to complex supra- and abdominal- aortic catheterizations. Methods A new (Qureshi 5) catheter with curved shape at the distal end that has two lumens was used. One of lumens can accommodate a 0.035-inch guide wire and the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen. The manipulation and engagement of the curved distal end catheter was facilitated by rotation and movement of the J-shaped 0.018-inch guide wire extended coaxial and beyond the distal end of catheter. Subsequently, either contrast was injected or a 0.035-inch guide wire advanced into the target artery. Results The catheters were used in one patient to perform diagnostic cerebral and abdominal angiography through a 6F introducer sheath placed in the right common femoral artery. The catheterization was complex because of severe tortuosity of arch and descending aorta secondary to kyphosis. The left and right internal carotid arteries and left and right vertebral arteries, left renal artery, and superior mesenteric artery were catheterized in patient (fluoroscopy time 19:46 min). No complications were observed in the patient. Conclusions The Qureshi-5 catheter was successful in complex supra- and abdominal-aortic catheterizations. PMID:26600925

  20. Qureshi-5 Catheter for Complex Supra- and Abdominal-Aortic Catheterization.

    PubMed

    Qureshi, Adnan I; Xiao, WeiGang; Liu, HongLiang

    2015-10-01

    The use of previously described catheter technique was expanded to complex supra- and abdominal- aortic catheterizations. A new (Qureshi 5) catheter with curved shape at the distal end that has two lumens was used. One of lumens can accommodate a 0.035-inch guide wire and the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen. The manipulation and engagement of the curved distal end catheter was facilitated by rotation and movement of the J-shaped 0.018-inch guide wire extended coaxial and beyond the distal end of catheter. Subsequently, either contrast was injected or a 0.035-inch guide wire advanced into the target artery. The catheters were used in one patient to perform diagnostic cerebral and abdominal angiography through a 6F introducer sheath placed in the right common femoral artery. The catheterization was complex because of severe tortuosity of arch and descending aorta secondary to kyphosis. The left and right internal carotid arteries and left and right vertebral arteries, left renal artery, and superior mesenteric artery were catheterized in patient (fluoroscopy time 19:46 min). No complications were observed in the patient. The Qureshi-5 catheter was successful in complex supra- and abdominal-aortic catheterizations.

  1. Silicon sensors for catheters and guide wires

    NASA Astrophysics Data System (ADS)

    Goosen, Hans F.

    2001-11-01

    One area that can make use of the miniature size of present day micro electromechanical systems (MEMS) is that of the medical field of minimally invasive interventions. These procedures, used for both diagnosis and treatment, use catheters that are advanced through the blood vessels deep into the body, without the need for surgery. However, once inside the body, the doctor performing the procedure is completely reliant on the information the catheter(s) can provide in addition to the projection imaging of a fluoroscope. A good range of sensors for catheters is required for a proper diagnosis. To this end, miniature sensors are being developed to be fitted to catheters and guide wires. As the accurate positioning of these instruments is problematic, it is necessary to combine several sensors on the same guide wire or catheter to measure several parameters in the same location. This however, brings many special problems to the design of the sensors, such as small size, low power consumption, bio-compatibility of materials, robust design for patient safety, a limited number of connections, packaging, etc. This paper will go into both the advantages and design problems of micromachined sensors and actuators in catheters and guide wires. As an example, a multi parameter blood sensor, measuring flow velocity, pressure and oxygen saturation, will be discussed.

  2. Video-assisted thoracoscopic surgery for pulmonary nodules after computed tomography-guided marking with a spiral wire.

    PubMed

    Eichfeld, Uwe; Dietrich, Arne; Ott, Rudolph; Kloeppel, Rainer

    2005-01-01

    Peripheral pulmonary nodules are preferably removed by minimally invasive techniques, such as video-assisted thoracoscopic (VATS) surgery. These nodules should be marked preoperatively for better intraoperative detection and removal. Twenty-two cases with a single pulmonary nodule requiring surgical removal for histologic examination were included in a prospective study. Guided by computed tomography, nodules were marked preoperatively using a laser marker system and fixed with a spiral wire. The marked nodules were removed by VATS surgery immediately after the marking. The marking wire was placed in all 22 patients without any complications. The marked nodule was completely removed by VATS surgery in 19 patients. Conversion to thoracotomy was necessary in 3 patients, twice because of thoracoscopy-related problems and once because of a marking failure. The average times for the marking procedure and operation were 24 minutes and 32 minutes, respectively. This new method of computed tomography-guided nodule marking with a spiral wire and subsequent VATS surgery is very efficient in terms of localization and stable fixation of subpleural pulmonary nodules.

  3. A unique complication of radiofrequency therapy to the tongue base

    PubMed Central

    Tornari, Chrysostomos; Wong, Gentle; Arora, Asit; Kotecha, Bhik

    2015-01-01

    Introduction Radiofrequency ablation treatment of the tongue base can be used either alone or as part of a multilevel approach in the treatment of snoring. This involves the generation of thermal energy around the circumvallate papillae of the tongue. Potential complications include ulceration, dysphagia, haematoma and abscess formation. Presentation of case We present the case of a 50-year-old patient who developed an anterior neck swelling following a second application of radiofrequency ablation therapy to the tongue base for snoring. This was secondary to an infection of a previously undiagnosed thyroglossal cyst. The patient made a full recovery following intravenous antibiotic therapy and ultrasound-guided needle aspiration. Discussion Thyroglossal tract remnants are thought to be present in seven percent of the adult population. An infection in a thyroglossal tract cyst has not previously been reported following radiofrequency ablation of the tongue base. Given the relatively high complication rate of tongue base radiofrequency ablation in some series, this complication may be under-recognised. Conclusion An infected thyroglossal tract cyst should be suspected in patients with anterior neck swellings following radiofrequency ablation therapy to the tongue base. We advise caution when performing this procedure on patients with known thyroglossal tract remnants though there is insufficient evidence to suggest that this procedure is contraindicated. PMID:25603484

  4. Active shielding of cylindrical saddle-shaped coils: application to wire-wound RF coils for very low field NMR and MRI.

    PubMed

    Bidinosti, C P; Kravchuk, I S; Hayden, M E

    2005-11-01

    We provide an exact expression for the magnetic field produced by cylindrical saddle-shaped coils and their ideal shield currents in the low-frequency limit. The stream function associated with the shield surface current is also determined. The results of the analysis are useful for the design of actively shielded radio-frequency (RF) coils. Examples pertinent to very low field nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) are presented and discussed.

  5. Conventional Radiofrequency Thermocoagulation vs Pulsed Radiofrequency Neuromodulation of Ganglion Impar in Chronic Perineal Pain of Nononcological Origin.

    PubMed

    Usmani, Hammad; Dureja, G P; Andleeb, Roshan; Tauheed, Nazia; Asif, Naiyer

    2018-01-10

    Chronic nononcological perineal pain has been effectively managed by ganglion Impar block. Chemical neurolysis, cryoablation, and radiofrequency ablation have been the accepted methods of blockade. Recently, pulsed radiofrequency, a novel variant of conventional radiofrequency, has been used for this purpose. This was a prospective, randomized, double-blind study. Two different interventional pain management centers in India. To compare the efficacy of conventional radiofrequency and pulsed radiofrequency for gangliom Impar block. The patients were randomly allocated to one of two groups. In the conventional radiofrequency (CRF) group (N = 34), conventional radiofrequency ablation was done, and in the PRF pulsed radiofrequency (PRF) group (N = 31), pulsed radiofrequency ablation was done. After informed and written consent, fluoroscopy-guided ganglion Impar block was performed through the first intracoccygeal approach. The extent of pain relief was assessed by visual analog scale (VAS) at 24 hours, and at the first, third, and sixth weeks following the intervention. A questionnaire to evaluate subjective patient satisfaction was also used at each follow-up visit. In the CRF group, the mean VAS score decreased significantly from the baseline value at each follow-up visit. But in the PRF group, this decrease was insignificant except at 24-hour follow-up. Intergroup comparison also showed significantly better pain relief in the CRF group as compared with the PRF group. At the end of follow-up, 28 patients (82%) in the CRF group and four patients (13%) in the PRF group had excellent results, as assessed by the subjective patient satisfaction questionnaire. There was no complication in any patient of either study group, except for short-lived infection at the site of skin puncture in a few. Ganglion Impar block by conventional radiofrequency provided a significantly better quality of pain relief with no major side effects in patients with chronic nononcological perineal pain as compared with pulsed radiofrequency. The short-term follow-up period of only six weeks was a major drawback associated with this study. © 2018 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  6. Endoscopic ultrasound-guided radiofrequency ablation for management of benign solid pancreatic tumors.

    PubMed

    Choi, Jun-Ho; Seo, Dong-Wan; Song, Tae Jun; Park, Do Hyun; Lee, Sang Soo; Lee, Sung Koo; Kim, Myung-Hwan

    2018-05-04

     Radiofrequency ablation (RFA) has been increasingly employed in experimental and clinical settings for the management of pancreatic lesions. This study aimed to assess the safety and efficacy of endoscopic ultrasound (EUS)-guided RFA for benign solid pancreatic tumors.  In a single-center, prospective study, 10 patients with benign solid pancreatic tumors underwent EUS-RFA. After the RFA electrode had been inserted into the pancreatic mass, the radiofrequency generator was activated to deliver 50 W of ablation power.  Among the 10 patients, 16 sessions of EUS-RFA were successfully performed. Diagnoses included nonfunctioning neuroendocrine tumor (n = 7), solid pseudopapillary neoplasm (n = 2), and insulinoma (n = 1); the median largest diameter of the tumors was 20 mm (range 8 - 28 mm). During follow-up (median 13 months), radiologic complete response was achieved in seven patients. Two adverse events (12.4 %; 1 moderate and 1 mild) occurred.  EUS-RFA may be a safe and potentially effective treatment option in selected patients with benign solid pancreatic tumors. Multiple sessions may be required if there is a remnant tumor, and adverse events must be carefully monitored. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Implementing Cleaner Printed Wiring Board Technologies: Surface Finishes

    EPA Pesticide Factsheets

    This document describes the problems, solutions, and time and effort involved in implementing alternative surface finish technologies, and this guide is produced as part of the DfE Printed Wiring Board Project

  8. Retrograde intubation: an alternative way for the management of difficult airway.

    PubMed

    Lama, P; Shrestha, B R

    2008-01-01

    Inserting a retrograde wire into the pharynx through a cricothyroid puncture can facilitate tracheal intubation in difficult situations where either a flexible fiber-optic bronchoscope or an expert user of such a device is not available. Even in cases when fibropric can not be negotiated for the purpose, this method has been claimed to be useful to manage the airway. Some mouth opening is essential for the oral or nasal retrieval of the wire from the pharynx. Here, a case of post mandibular reconstructed wound infection required surgical debridement and plate removal from reconstructed lower mandible under general anesthesia. We retrieved the guide wire passed through a cricothyroid puncture and subsequently accomplished wire-guided oro-tracheal intubation. In the absence of a flexible fiber-optic bronchoscope, this technique is a very useful aid to intubate patients with limited mouth opening.

  9. Early Stage Hepatocellular Carcinomas Not Feasible for Ultrasound-Guided Radiofrequency Ablation: Comparison of Transarterial Chemoembolization Alone and Combined Therapy with Transarterial Chemoembolization and Radiofrequency Ablation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hyun, Dongho; Cho, Sung Ki, E-mail: chosk@skku.edu; Shin, Sung Wook

    2016-03-15

    PurposeTo report the results of combined therapy with transarterial chemoembolization (TACE) and radiofrequency ablation (RFA) for early stage hepatocellular carcinoma (HCC) considered infeasible for ultrasound (US)-guided RFA in comparison with those of TACE monotherapy.MethodsFrom January 2007 through December 2010, 91 patients with early or very early stage HCC infeasible for US-guided RFA received either TACE alone (TACE group; n = 54) or TACE immediately followed by RFA (TACE–RFA group; n = 37) as a first-line treatment. 1-month tumor response, time to progression (TTP), and overall survival (OS) rates were calculated. Univariate and multivariate analyses were performed to identify prognostic factors.ResultsTACE–RFA group showed a bettermore » 1-month tumor response than TACE group (P < .001). The mean TTP was 29.7 ± 3.4 months (95 % confidence intervals [CIs] 23.0–36.5) in TACE group and 34.9 ± 2.8 months (95 % CIs 29.4–40.4) in TACE–RFA group. TACE–RFA group had a significantly longer TTP (P = .014). Cumulative 1-, 2-, and 3-year OS rates in the TACE and TACE–RFA groups were 91, 79, and 71 % and 100, 97, and 93 %, respectively (P = .008). Initial treatment of TACE was found to be the only significant risk factor for tumor progression and OS in multivariate analysis.ConclusionTACE–RFA combination therapy appears superior to TACE monotherapy in terms of 1-month tumor response, TTP, and OS when performed for early stage HCC infeasible for US-guided RFA.« less

  10. Technical success, technique efficacy and complications of minimally-invasive imaging-guided percutaneous ablation procedures of breast cancer: A systematic review and meta-analysis.

    PubMed

    Mauri, Giovanni; Sconfienza, Luca Maria; Pescatori, Lorenzo Carlo; Fedeli, Maria Paola; Alì, Marco; Di Leo, Giovanni; Sardanelli, Francesco

    2017-08-01

    To systematically review studies concerning imaging-guided minimally-invasive breast cancer treatments. An online database search was performed for English-language articles evaluating percutaneous breast cancer ablation. Pooled data and 95% confidence intervals (CIs) were calculated. Technical success, technique efficacy, minor and major complications were analysed, including ablation technique subgroup analysis and effect of tumour size on outcome. Forty-five studies were analysed, including 1,156 patients and 1,168 lesions. Radiofrequency (n=577; 50%), microwaves (n=78; 7%), laser (n=227; 19%), cryoablation (n=156; 13%) and high-intensity focused ultrasound (HIFU, n=129; 11%) were used. Pooled technical success was 96% (95%CI 94-97%) [laser=98% (95-99%); HIFU=96% (90-98%); radiofrequency=96% (93-97%); cryoablation=95% (90-98%); microwave=93% (81-98%)]. Pooled technique efficacy was 75% (67-81%) [radiofrequency=82% (74-88); cryoablation=75% (51-90); laser=59% (35-79); HIFU=49% (26-74)]. Major complications pooled rate was 6% (4-8). Minor complications pooled rate was 8% (5-13%). Differences between techniques were not significant for technical success (p=0.449), major complications (p=0.181) or minor complications (p=0.762), but significant for technique efficacy (p=0.009). Tumour size did not impact on variables (p>0.142). Imaging-guided percutaneous ablation techniques of breast cancer have a high rate of technical success, while technique efficacy remains suboptimal. Complication rates are relatively low. • Imaging-guided ablation techniques for breast cancer are 96% technically successful. • Overall technique efficacy rate is 75% but largely inhomogeneous among studies. • Overall major and minor complication rates are low (6-8%).

  11. Arthroscopic fixation of the clavicle shaft fracture.

    PubMed

    Kim, Yang-Soo; Lee, Hyo-Jin; Kim, Jong-Ick; Yang, Hyo; Jin, Hong-Ki; Patel, Hiren Kirtibhai; Kim, Jong-Ho; Park, In

    2017-01-01

    This article describes an arthroscopic technique for the fixation of clavicle shaft fractures. A viewing portal is made 2 cm anterior to the fracture site, and a working portal is made 2 cm lateral to the fracture site. The guide wire for a 4.0-mm cannulated screw is inserted through the fracture site to the medial fracture fragment under arthroscopic guidance. Through the medial fragment, the guide wire is delivered through the skin anteriorly. The fracture is reduced, and then, the guide wire is drilled back across the fracture site to the lateral fracture fragment. After confirming the reduction under arthroscopy, the appropriately sized cannulated screw is inserted after reaming. This arthroscopic technique would be useful for the precise reduction and minimal invasive fixation of clavicle shaft fractures. Preliminary results are encouraging, and further studies with long-term follow-up are needed to determine the precise indications and limitations of the procedure.

  12. [Clinical study on patients with renal-cell carcinoma accompanied with Von Hippel-Lindau disease treated with radiofrequency ablation].

    PubMed

    Nao, Tomoya; Shimamoto, Tsutomu; Karashima, Takashi; Kamei, Maiko; Fukuhara, Hideo; Fukata, Satoshi; Satake, Hirofumi; Ashida, Shingo; Yamasaki, Ichiro; Kamata, Masayuki; Inoue, Keiji; Yamanishi, Tomoaki; Ogawa, Yasuhiro; Ito, Satoshi; Shuin, Taro

    2014-09-01

    We report 12 renal cell carcinomas in 6 patients with Von Hippel-Lindau (VHL) disease treated with radiofrequency ablation (RFA). The mean age of the patients was 46 (range 38-53) years (male : 4, female : 2). Computed tomography (CT)-guided transcutaneous RFA was performed under conscious sedation with local anesthetics. The mean size of the tumors was 2.4 (range 0.7-8.1) cm. Nine of the 12 tumors (75%) were locally well controlled. However, 3 tumors in 2 patients developed visceral metastases after RFA. While minimal flank pain, nausea, perinephritic hematoma and lumbago were observed, there was no major complication during or after the procedure. The therapy with CT-guided transcutaneous RFA is efficient and minimal invasive for renal cell carcinoma in patients with VHL, leading to preservation of renal function.

  13. Experimental application of thermosensitive paramagnetic liposomes for monitoring magnetic resonance imaging guided thermal ablation.

    PubMed

    Frich, Lars; Bjørnerud, Atle; Fossheim, Sigrid; Tillung, Terje; Gladhaug, Ivar

    2004-12-01

    The use of a liposomal paramagnetic agent with a T(1)-relaxivity that increases markedly at temperatures above the phase transition temperature (T(m)) of the liposomal membrane was evaluated during magnetic resonance imaging (MRI) guided hyperthermia ablation. A neodymium-yttrium aluminum garnet (Nd-YAG) laser unit and a radiofrequency ablation system were used for tissue ablation in eight rabbit livers in vivo. One ablation was made in each animal prior to administration of the liposomal agent. Liposomes with a T(m) of 57 degrees C containing gadodiamide (GdDTPA-BMA) were injected iv, and two additional ablations were performed. T(1)-weighted scans were performed in heated tissue, after tissue temperature had normalized, and 15-20 min after normalization of tissue temperature. Increase in signal intensity (DeltaSI) for ablations prior to injection of the agent was 13.0% (SD = 5.7) for the laser group and 9.1% (SD = 7.9) for the radiofrequency group. Signal intensity after administration of the agent unrelated to heating was not statistically significant (DeltaSI = 1.4%, P = 0.35). For ablations made after injection of the agent, a significant increase was found in the laser (DeltaSI = 34.5%, SD = 11.9) and radiofrequency group (DeltaSI = 21.6%, SD = 22.7). The persistent signal enhancement found in areas exposed to a temperature above the threshold temperature above T(m) allows thermal monitoring of MRI guided thermal ablation. (c) 2004 Wiley-Liss, Inc.

  14. Wire inhomogeneity detector having a core with opposing pole pieces and guide pieces adjacent the opposing pole pieces

    DOEpatents

    Gibson, George H.; Smits, Robert G.; Eberhard, Philippe H.

    1989-01-01

    A device for uncovering imperfections in electrical conducting wire, particularly superconducting wire, by detecting variations in eddy currents. Eddy currents effect the magnetic field in a gap of an inductor, contained in a modified commercial ferrite core, through which the wire being tested is passed. A small increase or decrease in the amount of conductive material, such as copper, in a fixed cross section of wire will unbalance a bridge used to measure the impedance of the inductor, tripping a detector and sounding an alarm.

  15. LOADED WAVE GUIDES FOR LINEAR ACCELERATORS

    DOEpatents

    Walkinshaw, W.; Mullett, L.B.

    1959-12-01

    A periodically loaded waveguide having substantially coaxially arranged elements which provide an axial field for the acceleration of electrons is described. Radiofrequency energy will flow in the space between the inner wall of an outer guide and the peripheries of equally spaced irises or washes arranged coaxially with each other and with the outer guide, where the loading due to the geometry of the irises is such as to reduce the phase velocity of the r-f energy flowing in the guide from a value greater than that of light to the velocity of light or less.

  16. The Wire-Grasping Method as a New Technique for Forceps Biopsy of Biliary Strictures: A Prospective Randomized Controlled Study of Effectiveness

    PubMed Central

    Yamashita, Yasunobu; Ueda, Kazuki; Kawaji, Yuki; Tamura, Takashi; Itonaga, Masahiro; Yoshida, Takeichi; Maeda, Hiroki; Magari, Hirohito; Maekita, Takao; Iguchi, Mikitaka; Tamai, Hideyuki; Ichinose, Masao; Kato, Jun

    2016-01-01

    Background/Aims Transpapillary forceps biopsy is an effective diagnostic technique in patients with biliary stricture. This prospective study aimed to determine the usefulness of the wire-grasping method as a new technique for forceps biopsy. Methods Consecutive patients with biliary stricture or irregularities of the bile duct wall were randomly allocated to either the direct or wire-grasping method group. In the wire-grasping method, forceps in the duodenum grasps a guide-wire placed into the bile duct beforehand, and then, the forceps are pushed through the papilla without endoscopic sphincterotomy. In the direct method, forceps are directly pushed into the bile duct alongside a guide-wire. The primary endpoint was the success rate of obtaining specimens suitable for adequate pathological examination. Results In total, 32 patients were enrolled, and 28 (14 in each group) were eligible for analysis. The success rate was significantly higher using the wire-grasping method than the direct method (100% vs 50%, p=0.016). Sensitivity and accuracy for the diagnosis of cancer were comparable in patients with the successful procurement of biopsy specimens between the two methods (91% vs 83% and 93% vs 86%, respectively). Conclusions The wire-grasping method is useful for diagnosing patients with biliary stricture or irregularities of the bile duct wall. PMID:27021502

  17. A Case of Chronic Total Occlusion of the Left Anterior Descending Artery Successfully Treated with Side Branch Technique Using the Soutenir CV

    PubMed Central

    Niizeki, Takeshi; Ikeno, Eiichiro; Kubota, Isao

    2017-01-01

    Patient: Male, 54 Final Diagnosis: Old myocardial infarction Symptoms: Lower extremity swelling • respiratory distress Medication: — Clinical Procedure: Success Specialty: Cardiology Objective: Unusual setting of medical care Background: Success rates for treatment of chronic total occlusion (CTO) have dramatically improved in recent years with the development of new CTO guidewires and development of new techniques such as the retrograde approach. In the antegrade approach, a guidewire is occasionally passed through a side branch despite successful wire crossing of the CTO lesion. In order to pass a wire through the main artery, there are a few side branch techniques such as a reverse wire technique. Case Report: A 54-year-old man with symptoms of heart failure was admitted to our hospital. Coronary angiography showed CTO of the proximal left anterior descending artery. Percutaneous coronary intervention with an antegrade approach was started. We succeeded in passing the wire through a side branch but not the main artery. Unfortunately, a reverse wire technique failed in this case. Next, the wire passed through a side branch was exchanged with the Soutenir CV, and a retrograde approach was started. The wire crossing from retrograde was entwined around the Soutenir CV. After that, the retrograde wire was snared and guided to the antegrade guiding catheter, which resulted in successful wiring into the main artery easily. Conclusions: The side branch technique using the Soutenir CV may be an effective strategy in some cases. PMID:28082733

  18. An intravascular loopless monopole antenna for vessel wall MR imaging at 3.0 T.

    PubMed

    Yuan, Hongyang; Lv, Xing; Ma, Xiaohai; Zhang, Rui; Fu, Youyi; Yang, Xuedong; Wang, Xiaoying; Zhang, Zhaoqi; Zhang, Jue; Fang, Jing

    2013-01-01

    The purpose of this study was to develop a novel intravascular loopless monopole antenna (ILMA) design specifically for imaging of small vessel walls. The ILMA consisted of an unshielded, low-friction guide wire and a tuning/matching box. The material of the guide wire was nitinol and it was coated with polyurethane. Because the guide wire was unshielded, it could be made thinner than the coaxial cable-based loopless intravascular antenna design. The material of the box was aluminum. In this study, the diameter of the guide wire was 0.5 mm and the length was 58.7 mm. The ILMA was used as a receiving antenna and body coil for transmission. To verify the feasibility of the ILMA, in vitro and in vivo experiments were performed on a 3.0-T magnetic resonance (MR) scanner. In vitro tests using the ILMA indicated that the proposed design could be used to image target vessel walls with a spatial resolution of 313 μm at the frequency coding direction and more than 100 mm of longitudinal coverage. In vivo tests demonstrated that the images showed the vessel walls clearly by using the ILMA and also indicated that the ILMA could be used for small vessels. The proposed antenna may therefore be utilized to promote MR-based diagnoses and therapeutic solutions for cardiovascular atherosclerotic diseases. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Transthoracic ultrasound guided balloon dilation of cor triatriatum dexter in 2 Rottweiler puppies.

    PubMed

    Birettoni, F; Caivano, D; Bufalari, A; Giorgi, M E; Miglio, A; Paradies, P; Porciello, F

    2016-12-01

    Balloon dilation was performed in two Rottweiler puppies with cor triatriatum dexter and clinical signs of ascites using transthoracic echocardiographic guidance. The dogs were positioned on a standard echocardiography table in right lateral recumbency, and guide wires and balloon catheters were imaged by echocardiographic views optimized to allow visualization of the defect. The procedures were performed successfully without complications and clinical signs were resolved completely in both cases. Guide wires and balloon catheters appeared hyperechoic on transthoracic echocardiography image and could be clearly monitored and guided in real-time. These two cases demonstrate that it is possible to perform balloon catheter dilation of cor triatriatum dexter under transthoracic guidance alone. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Pulsed radiofrequency on radial nerve under ultrasound guidance for treatment of intractable lateral epicondylitis.

    PubMed

    Oh, Dae Seok; Kang, Tae Hyung; Kim, Hyae Jin

    2016-06-01

    Lateral epicondylitis is a painful and functionally limiting disorder. Although lateral elbow pain is generally self-limiting, in a minority of people symptoms persist for a long time. When various conservative treatments fail, surgical approach is recommended. Surgical denervation of several nerves that innervate the lateral humeral epicondyle could be considered in patients with refractory pain because it denervates the region of pain. Pulsed radiofrequency is a minimally invasive procedure that improves chronic pain when applied to various neural tissues without causing any significant destruction and painful complication. This procedure is safe, minimally invasive, and has less risk of complications relatively compared to the surgical approach. The radial nerve can be identified as a target for pulsed radiofrequency lesioning in lateral epicondylitis. This innovative method of pulsed radiofrequency applied to the radial nerve has not been reported before. We reported on two patients with intractable lateral epicondylitis suffering from elbow pain who did not respond to nonoperative treatments, but in whom the ultrasound-guided pulsed radiofrequency neuromodulation of the radial nerve induced symptom improvement. After a successful diagnostic nerve block, radiofrequency probe adjustment around the radial nerve was performed on the lateral aspect of the distal upper arm under ultrasound guidance and multiple pulsed treatments were applied. A significant reduction in pain was reported over the follow-up period of 12 weeks.

  1. Accidental entrapment of an endo-bronchial blocker tip by a surgical stapler during selective ventilation for lung lobectomy in a dog.

    PubMed

    Levionnois, Olivier L; Bergadano, Alessandra; Schatzmann, Urs

    2006-01-01

    To describe the use of an endobronchial blocker (EBB) and to perform selective ventilation during pulmonary lobe resection via thoracotomy in a dog and report its accidental stapling in the resection site. Clinical case report. One female dog with a suspected abscess or neoplasia of the right caudal pulmonary lobe. One-lung ventilation was performed using a wire-guided EBB to seal the contaminated parenchyma and facilitate surgical access. The affected lung parenchyma was resected and the resection site was closed with staples. Lobar resection was performed successfully, but the loop of the EBB guide wire was inadvertently entrapped in the staple line of the lobectomy. Staples were removed to release the wire loop, and the resulting air leak caused loss of ventilation control until the parenchyma was re-sealed. We recommend removing the wire guide associate with the EBB after successful lung separation to avoid accidents that could have life-threatening consequences if not recognized. One-lung ventilation is useful to isolate healthy parenchyma from diseased parenchyma during lobectomy. Anesthesiologists and surgeons need to be aware of the potential complications associated with use of EBB.

  2. Image-guided radiofrequency ablation of spinal tumors: preliminary experience with an expandable array electrode.

    PubMed

    Grönemeyer, Dietrich H W; Schirp, Sven; Gevargez, Athour

    2002-01-01

    Metastases to the spine are a challenging problem. Percutaneous, image-guided tumor ablation with a thermal energy source, such as radiofrequency, has received increasing attention as a promising technique for the treatment of focal malignant disease. We used radiofrequency ablation for patients with unresectable, osteolytic spine metastases under computed tomographic and fluoroscopic guidance. The purpose of this study was to determine the feasibility, effectiveness, and safety of radiofrequency ablation as a palliative procedure to reduce pain and back pain-related disability in patients with vertebral and paravertebral spine tumors who were not able to benefit from radiotherapy, chemotherapy, or surgery. Between November 1999 and January 2001, 10 patients with unresectable spine metastases were treated with radiofrequency ablation. For the ablation we used a 50-W radiofrequency generator that is connected to an expandable electrode catheter (RITA Medical System Inc., Mountain View, CA). The mean patient age was 64.4 years. Metastases were ablated in the thoracic spine, the lumbar spine, and/or the sacral bone. Tumor diameter ranged from 1.5 to 9 cm. Combined computed tomographic and fluoroscopic guidance was used to guide the procedure. Operations were carried out without heavy sedation with the patient under local anesthesia only. The thermal lesion was produced by applying temperatures of 50 degrees to 120 degrees C for 8-12 minutes. Vertebroplasty was performed in four patients by use of 3 to 5.5 mL of polymethyl methacrylate. Therapy outcome was documented by magnet resonance imaging. Before the therapy and on follow-up of an average of 5.8 months, pain was assessed with the help of the Visual Analogue Scale. Back pain-related disability was measured with the Hannover Functional Ability Questionnaire. Neurologic and health status were documented on the Frankel score and the Karnofsky index. At follow-up, 9 of 10 patients reported reduced pain (Visual Analogue Scale). In patients who experienced pain relief, there was an average relative pain reduction of 74.4%. Back pain-related disability was reduced by an average of 27%. Neurologic function was preserved in nine patients and improved in one. General health was stabilized in six patients, slightly increased (by 10%-20%) in two patients, significantly enhanced (by 50%) in one patient, and slightly reduced in one patient. No complications were reported. In the treated region, magnetic resonance imaging showed no further tumor growth after the therapy. Radiofrequency ablation was successfully performed in all 10 patients. Needles were placed accurately under image guidance, and a controlled lesion was created. Pain- and back pain-related disability was clearly reduced, and neurologic function was preserved or stabilized. When confirmed by further investigation, this therapy may be a new option for patients with unresectable spine tumors that do not respond to radiotherapy and chemotherapy.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallace, Adam N., E-mail: wallacea@mir.wustl.edu; Tomasian, Anderanik, E-mail: tomasiana@mir.wustl.edu; Chang, Randy O., E-mail: changr@wusm.wustl.edu

    BackgroundPercutaneous CT-guided radiofrequency ablation is a safe and effective minimally invasive treatment for osteoid osteomas. This technical case series describes the use of a recently introduced ablation system with a probe that can be curved in multiple directions, embedded thermocouples for real-time monitoring of the ablation volume, and a bipolar design that obviates the need for a grounding pad.MethodsMedical records of all patients who underwent radiofrequency ablation of an osteoid osteoma with the STAR Tumor Ablation System (DFINE; San Jose, CA) were reviewed. The location of each osteoid osteoma, nidus volume, and procedural details were recorded. Treatment efficacy and long-termmore » complications were assessed at clinical follow-up.ResultsDuring the study period, 18 osteoid osteomas were radiofrequency ablated with the multidirectional bipolar system. Lesion locations included the femur (50 %; 9/18), tibia (22 %; 4/18), cervical spine (11 %; 2/18), calcaneus (5.5 %; 1/18), iliac bone (5.5 %; 1/18), and fibula (5.5 %; 1/18). The median nidus volume of these cases was 0.33 mL (range 0.12–2.0 mL). All tumors were accessed via a single osseous channel. Median cumulative ablation time was 5 min and 0 s (range 1 min and 32 s–8 min and 50 s). All patients with clinical follow-up reported complete symptom resolution. No complications occurred.ConclusionSafe and effective CT-guided radiofrequency ablation of osteoid osteomas can be performed in a variety of locations using a multidirectional bipolar system.« less

  4. Experimental study on TiN coated racetrack-type ceramic pipe

    NASA Astrophysics Data System (ADS)

    Wang, Jie; Xu, Yan-Hui; Zhang, Bo; Wei, Wei; Fan, Le; Pei, Xiang-Tao; Hong, Yuan-Zhi; Wang, Yong

    2015-11-01

    TiN film was coated on the internal surface of a racetrack-type ceramic pipe by three different methods: radio-frequency sputtering, DC sputtering and DC magnetron sputtering. The deposition rates of TiN film under different coating methods were compared. The highest deposition rate was 156 nm/h, which was obtained by magnetron sputtering coating. Based on AFM, SEM and XPS test results, the properties of TiN film, such as film roughness and surface morphology, were analyzed. Furthermore, the deposition rates were studied with two different cathode types, Ti wires and Ti plate. According to the SEM test results, the deposition rate of TiN/Ti film was about 800 nm/h with Ti plate cathode by DC magnetron sputtering. Using Ti plate cathode rather than Ti wire cathode can greatly improve the film deposition rate. Supported by National Nature Science Foundation of China (11075157)

  5. Radiofrequency dosimetry in subjects implanted with metallic straight wires: a numerical study.

    PubMed

    Mattei, E; Calcagnini, G; Censi, F; Triventi, M; Bartolini, P

    2008-01-01

    A numerical study to investigate the effects of the exposure to electromagnetic fields (EMF) at 900 and 1800 MHz on biological tissues implanted with thin metallic structures has been carried out, using the finite difference time domain (FDTD) solution technique. The results of the model show that the presence of a metallic wire yields to a significant increase in the local specific energy absorption rate (SAR). The present standards and/or guidelines on safe exposures of humans to EMF does not cover persons with implanted devices and thus the threshold levels to define safe exposure conditions might not apply in presence of high SAR gradients, such as the ones generated by thin metallic implanted objects. However, exposure to EMF fields below the actual safe levels even in presence of thin conductive structures cause rather low temperature rises (1 degrees C).

  6. Laparoscopic Ultrasound-Guided Radiofrequency Ablation of Uterine Fibroids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milic, Andrea; Asch, Murray R.; Hawrylyshyn, Peter A.

    Four patients with symptomatic uterine fibroids measuring less than 6 cm underwent laparoscopic ultrasound-guided radiofrequency ablation (RFA) using multiprobe-array electrodes. Follow-up of the treated fibroids was performed with gadolinium-enhanced magnetic resonance imaging (MRI) and patients' symptoms were assessed by telephone interviews. The procedure was initially technically successful in 3 of the 4 patients and MRI studies at 1 month demonstrated complete fibroid ablation. Symptom improvement, including a decrease in menstrual bleeding and pain, was achieved in 2 patients at 3 months. At 7 months, 1 of these 2 patients experienced symptom worsening which correlated with recurrent fibroid on MRI. Themore » third, initially technically successfully treated patient did not experience any symptom relief after the procedure and was ultimately diagnosed with adenomyosis. Our preliminary results suggest that RFA is a technically feasible treatment for symptomatic uterine fibroids in appropriately selected patients.« less

  7. Technique tip: use of anterior cruciate ligament jig for hindfoot fusion by calcanio-talo-tibial nail.

    PubMed

    Haque, Syed; Sarkar, Jay

    2012-08-01

    The use of intramedullary nail fixation for tibio-talo-calcaneal fusion is gaining popularity. There is chance of failure of procedure following faulty operative technique specially alignment. The article describes a useful application of tibial tunnel jig in inserting the calcanio-talo-tibial guide wire. There is precision of few millimeters in the exit point of guide wire on talus. The authors believe that this helps in better positioning of nail and hence better alignment and better operative outcome.

  8. Electrochemical Fabrication of Metallic Quantum Wires

    ERIC Educational Resources Information Center

    Tao, Nongjian

    2005-01-01

    The fabrication of metallic quantum wires using simple electrochemical techniques is described. The conductance of the system can be readily measured that allows one to constantly monitor the conductance during fabrication and use conductance quantization as a signature to guide the fabrication.

  9. Image-guided thermal therapy of uterine fibroids

    PubMed Central

    Shen, Shu-Huei; Fennessy, Fiona; McDannold, Nathan; Jolesz, Ferenc; Tempany, Clare

    2009-01-01

    Thermal ablation is an established treatment for tumor. The merging of newly developed imaging techniques has allowed precise targeting and real-time thermal mapping. This article provides an overview of the image-guided thermal ablation techniques in the treatment of uterine fibroids. Background on uterine fibroids, including epidemiology, histology, symptoms, imaging findings and current treatment options, is first outlined. After describing the principle of magnetic resonance thermal imaging, we introduce the applications of image-guided thermal therapies, including laser ablation, radiofrequency ablation, cryotherapy and particularly the newest, magnetic resonance-guided focused ultrasound surgery, and how they apply to uterine fibroid treatment. PMID:19358440

  10. Image guided radiofrequency thermo-ablation therapy of chondroblastomas: should it replace surgery?

    PubMed

    Lalam, Radhesh K; Cribb, Gillian L; Tins, Bernard J; Cool, Wim P; Singh, Jaspreet; Tyrrell, Prudencia N M; Cassar-Pullicino, Victor N

    2014-04-01

    To assess the safety and effectiveness of image-guided radiofrequency ablation (RF ablation) in the treatment of chondroblastomas as an alternative to surgery. Twelve patients with histologically proven chondroblastoma at our institution from 2003 to date. We reviewed the indications, recurrences and complications in patients who underwent RF ablation. Twelve patients were diagnosed with chondroblastoma. Out of these, 8 patients (6 male, 2 female, mean age 17 years) with chondroblastoma (mean size 2.7 cm) underwent RF ablation. Multitine expandable electrodes were used in all patients. The number of probe positions needed varied from 1 to 4 and lesions were ablated at 90 °C for 5 min at each probe position. The tumours were successfully treated and all patients became asymptomatic. There were no recurrences. There were 2 patients with knee complications, 1 with minor asymptomatic infraction of the subchondral bone and a second patient with osteonecrosis/chondrolysis. Radiofrequency ablation appears to be a safe and effective alternative to surgical treatment with a low risk of recurrence and complications for most chondroblastomas. RF ablation is probably superior to surgery when chondroblastomas are small (less than 2.5 cm) with an intact bony margin with subchondral bone and in areas of difficult surgical access.

  11. [Current strategy in PCI for CTO].

    PubMed

    Asakura, Yasushi

    2011-02-01

    Recently, CTO PCI has come into wide use all over the world and it has been standardized. The 1st step is an antegrade approach using single wire. The 2nd strategy would be parallel wire technique. And the next would be a retrograde approach. In this method, retrograde wiring with Corsair is done at first. If it is successful, externalization is established using 300 cm wire, and this system is able to provide strong back-up support. If it fails, reverse CART technique is the next step. IVUS guided wiring is a last resort. The 2nd wire is manipulated with IVUS guidance. Now, initial success rate is more than 90% with these methods.

  12. A patient-mount navigated intervention system for spinal diseases and its clinical trial on percutaneous pulsed radiofrequency stimulation of dorsal root ganglion.

    PubMed

    Yang, Chi-Lin; Yang, Been-Der; Lin, Mu-Lien; Wang, Yao-Hung; Wang, Jaw-Lin

    2010-10-01

    Development of a patient-mount navigated intervention (PaMNI) system for spinal diseases. An in vivo clinical human trial was conducted to validate this system. To verify the feasibility of the PaMNI system with the clinical trial on percutaneous pulsed radiofrequency stimulation of dorsal root ganglion (PRF-DRG). Two major image guiding techniques, i.e., computed tomography (CT)-guided and fluoro-guided, were used for spinal intervention. The CT-guided technique provides high spatial resolution, and is claimed to be more accurate than the fluoro-guided technique. Nevertheless, the CT-guided intervention usually reaches higher radiograph exposure than the fluoro-guided counterpart. Some navigated intervention systems were developed to reduce the radiation of CT-guided intervention. Nevertheless, these systems were not popularly used due to the longer operation time, a new protocol for surgeons, and the availability of such a system. The PaMNI system includes 3 components, i.e., a patient-mount miniature tracking unit, an auto-registered reference frame unit, and a user-friendly image processing unit. The PRF-DRG treatment was conducted to find the clinical feasibility of this system. The in vivo clinical trial showed that the accuracy, visual analog scale evaluation after surgery, and radiograph exposure of the PaMNI-guided technique are comparable to the one of conventional fluoro-guided technique, while the operation time is increased by 5 minutes. Combining the virtues of fluoroscopy and CT-guided techniques, our navigation system is operated like a virtual fluoroscopy with augmented CT images. This system elevates the performance of CT-guided intervention and reduces surgeons' radiation exposure risk to a minimum, while keeping low radiation dose to patients like its fluoro-guided counterpart. The clinical trial of PRF-DRG treatment showed the clinical feasibility and efficacy of this system.

  13. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis.

    PubMed

    Aryana, Arash; Singh, Sheldon M; Mugnai, Giacomo; de Asmundis, Carlo; Kowalski, Marcin; Pujara, Deep K; Cohen, Andrew I; Singh, Steve K; Fuenzalida, Charles E; Prager, Nelson; Bowers, Mark R; O'Neill, Padraig Gearoid; Brugada, Pedro; d'Avila, André; Chierchia, Gian-Battista

    2016-12-01

    Catheter ablation of atrial fibrillation (CAAF) using the cryoballoon has emerged as an alternate strategy to point-by-point radiofrequency. However, there is little comparative data on long-term durability of pulmonary vein (PV) isolation comparing these two modalities. In this multicenter, retrospective analysis, the incidences/patterns of late PV reconnection following an index CAAF using the second-generation cryoballoon versus open-irrigated, non-force-sensing radiofrequency were examined. Of the 2002 patients who underwent a first-time CAAF, 186/1126 patients (16.5 %) ablated using cryoballoon and 174/876 patients (19.9 %) with non-contact force-guided radiofrequency required a repeat procedure at 11 ± 5 months. During follow-up, the incidence of atrial flutters/tachycardias was lower (19.9 vs. 32.8 %; p = 0.005) and fewer patients exhibited PV reconnection (47.3 vs. 60.9 %; p = 0.007) with cryoballoon versus radiofrequency. Additionally, fewer PVs had reconnected with cryoballoon versus radiofrequency (18.8 vs. 34.6 %; p < 0.001). With cryoballoon, the right inferior (p < 0.001) and left common (p = 0.039) PVs were more likely to exhibit late reconnection, versus the left superior PV with radiofrequency (p = 0.012). However, when comparing the two strategies, the left common PV was more likely to exhibit reconnection with cryoballoon, whereas all other PVs with the exception of the right inferior PV demonstrated a lower reconnection rate with cryoballoon versus radiofrequency. Lastly, in a logistic regression multivariate analysis, cryoballoon ablation and PV ablation time emerged as significant predictors of durable PV isolation at repeat procedure. In this large multicenter, retrospective analysis, CAAF using the second-generation cryoballoon was associated with improved durability of PV isolation compared to open-irrigated, non-force-sensing radiofrequency.

  14. High accuracy electronic material level sensor

    DOEpatents

    McEwan, T.E.

    1997-03-11

    The High Accuracy Electronic Material Level Sensor (electronic dipstick) is a sensor based on time domain reflectometry (TDR) of very short electrical pulses. Pulses are propagated along a transmission line or guide wire that is partially immersed in the material being measured; a launcher plate is positioned at the beginning of the guide wire. Reflected pulses are produced at the material interface due to the change in dielectric constant. The time difference of the reflections at the launcher plate and at the material interface are used to determine the material level. Improved performance is obtained by the incorporation of: (1) a high accuracy time base that is referenced to a quartz crystal, (2) an ultrawideband directional sampler to allow operation without an interconnect cable between the electronics module and the guide wire, (3) constant fraction discriminators (CFDs) that allow accurate measurements regardless of material dielectric constants, and reduce or eliminate errors induced by triple-transit or ``ghost`` reflections on the interconnect cable. These improvements make the dipstick accurate to better than 0.1%. 4 figs.

  15. High accuracy electronic material level sensor

    DOEpatents

    McEwan, Thomas E.

    1997-01-01

    The High Accuracy Electronic Material Level Sensor (electronic dipstick) is a sensor based on time domain reflectometry (TDR) of very short electrical pulses. Pulses are propagated along a transmission line or guide wire that is partially immersed in the material being measured; a launcher plate is positioned at the beginning of the guide wire. Reflected pulses are produced at the material interface due to the change in dielectric constant. The time difference of the reflections at the launcher plate and at the material interface are used to determine the material level. Improved performance is obtained by the incorporation of: 1) a high accuracy time base that is referenced to a quartz crystal, 2) an ultrawideband directional sampler to allow operation without an interconnect cable between the electronics module and the guide wire, 3) constant fraction discriminators (CFDs) that allow accurate measurements regardless of material dielectric constants, and reduce or eliminate errors induced by triple-transit or "ghost" reflections on the interconnect cable. These improvements make the dipstick accurate to better than 0.1%.

  16. Risk assessment and management of radiofrequency radiation exposure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dabala, Dana; Surducan, Emanoil; Surducan, Vasile

    2013-11-13

    Radiofrequency radiation (RFR) industry managers, occupational physicians, security department, and other practitioners must be advised on the basic of biophysics and the health effects of RF electromagnetic fields so as to guide the management of exposure. Information on biophysics of RFR and biological/heath effects is derived from standard texts, literature and clinical experiences. Emergency treatment and ongoing care is outlined, with clinical approach integrating the circumstances of exposure and the patient's symptoms. Experimental risk assessment model in RFR chronic exposure is proposed. Planning for assessment and monitoring exposure, ongoing care, safety measures and work protection are outlining the proper management.

  17. Risk assessment and management of radiofrequency radiation exposure

    NASA Astrophysics Data System (ADS)

    Dabala, Dana; Surducan, Emanoil; Surducan, Vasile; Neamtu, Camelia

    2013-11-01

    Radiofrequency radiation (RFR) industry managers, occupational physicians, security department, and other practitioners must be advised on the basic of biophysics and the health effects of RF electromagnetic fields so as to guide the management of exposure. Information on biophysics of RFR and biological/heath effects is derived from standard texts, literature and clinical experiences. Emergency treatment and ongoing care is outlined, with clinical approach integrating the circumstances of exposure and the patient's symptoms. Experimental risk assessment model in RFR chronic exposure is proposed. Planning for assessment and monitoring exposure, ongoing care, safety measures and work protection are outlining the proper management.

  18. Fluoroscopic guide wire manipulation of malfunctioning peritoneal dialysis catheters initially placed by interventional radiologists.

    PubMed

    Kwon, Young Ho; Kwon, Se Hwan; Oh, Joo Hyeong; Jeong, Kyung Hwan; Lee, Tae Won

    2014-06-01

    To assess the efficacy of fluoroscopic guide wire manipulation in patients with malfunctioning peritoneal dialysis (PD) catheters that were initially placed by interventional radiologists under fluoroscopic guidance. From January 2002 to April 2012, 52 patients (mean age, 52.8 y ± 2.10s; range, 12-79 y) with malfunctioning PD catheters in whom fluoroscopic guide wire manipulation was performed were retrospectively reviewed. Technical success, clinical success, and complications were evaluated. Technical success was defined as fluoroscopically verified, successful catheter repositioning and adequate dialysate drainage after the procedure. Clinical success was defined as maintenance of PD catheter function for at least 30 days after the manipulation. During the study period, 72 manipulations (68 initial manipulations and 4 remanipulations) for malfunctioning PD catheters were done. The technical success rate was 74% (50 of 68) for initial manipulations and 75% (3 of 4) for remanipulations. The overall clinical success rate was 47% (32 of 68) for initial manipulations and 0% (0 of 4) for remanipulations. The primary causes of catheter malfunction were extraluminal obstruction by omental wrapping or adhesions in 43 of 68 cases (63.2%) and catheter malposition in 25 of 68 (36.8%) cases. There were no procedure-related major complications. Fluoroscopic guide wire manipulation in patients with malfunctioning PD catheters initially placed by interventional radiologists is a simple procedure, an effective way of prolonging PD catheter life, and a recommended procedure before invasive surgical procedures. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  19. Preliminary Experience with use of Qureshi-5 Catheters for Diagnostic Cerebral Angiography.

    PubMed

    Qureshi, Adnan I; Yan, Xiao; Liu, HongLiang

    2015-05-01

    A catheter technique was developed to overcome current challenges in the stabilization and manipulation of catheter in tortuous arteries such as right subclavian artery and left common carotid artery. The new catheter has the following two lumens: first lumen can accommodate a 0.035-inch guide wire (lumen A) and a curved shape at the distal end; the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen (lumen B). The catheter is withdrawn or advanced over the 0.018-inch guide wire and the curved free end of catheter manipulated until the end engages the origin of the target artery. Subsequently, either contrast can be injected or a 0.035-inch guide wire advanced into the target artery. The catheters were used in two patients to perform diagnostic cerebral angiography through a 6F introducer sheath placed in the right common femoral artery. The left and right common carotid arteries and left and right vertebral arteries were catheterized in first patient (contrast used 50 ml; fluoroscopy time 20:09 min). The left and right internal carotid arteries, left and right subclavian arteries, and left external carotid artery were catheterized in second patient (contrast used 40 ml; fluoroscopy time 13:56 min). No complications were observed in either of the two patients. The performance of the new catheter for catheterization of multiple arteries in two patients was considered adequate with high-quality angiographic image acquisitions.

  20. A multiplanar complex resection of a low-grade chondrosarcoma of the distal femur guided by K-wires previously inserted under CT-guide: a case report.

    PubMed

    Zoccali, Carmine; Rossi, Barbara; Ferraresi, Virginia; Anelli, Vincenzo; Rita, Alessandro

    2014-08-13

    In muscular skeletal oncology aiming to achieve wide surgical margin is one of the main factors influencing patient prognosis. In cases where lesions are either meta or epiphyseal, surgery most often compromises joint integrity and stability because muscles, tendons and ligaments are involved in wide resection. When lesions are well circumscribed they can be completely resected by performing multi-planar osteotomies guided by computer-assisted navigation. We describe a case of low-grade chondrosarcoma of the distal femur where a simple but effective technique was useful to perform complex multiplanar osteotomies. No similar techniques are reported in the literature. A 57 year-old Caucasian female was referred to our department for the presence of a distal femur chondrosarcoma. A resection with the presenting technique was scheduled. The first step consists of inserting several K-wires under CT-scan control to delimitate the tumor; the second step consists of tumor removal: in operative theatre, following surgical access, k-wires are used as guide positioning; scalpels are externally placed to k-wires to perform a safe osteotomy. Computed assisted resections can be considered the most advantageous method to reach the best surgical outcome; unfortunately navigation systems are only available in specialized centres. The present technique allows for a multiplanar complex resection when navigation systems are not available. This technique can be applied in low-grade tumours where a minimal wide margin can be considered sufficient.

  1. MR Coagulation: A Novel Minimally Invasive Approach to Aneurysm Repair.

    PubMed

    Cohen, Ouri; Zhao, Ming; Nevo, Erez; Ackerman, Jerome L

    2017-11-01

    To demonstrate a proof of concept of magnetic resonance (MR) coagulation, in which MR imaging scanner-induced radiofrequency (RF) heating at the end of an intracatheter long wire heats and coagulates a protein solution to effect a vascular repair by embolization. MR coagulation was simulated by finite-element modeling of electromagnetic fields and specific absorption rate (SAR) in a phantom. A glass phantom consisting of a spherical cavity joined to the side of a tube was incorporated into a flow system to simulate an aneurysm and flowing blood with velocities of 0-1.7 mL/s. A double-lumen catheter containing the wire and fiberoptic temperature sensor in 1 lumen was passed through the flow system into the aneurysm, and 9 cm 3 of protein solution was injected into the aneurysm through the second lumen. The distal end of the wire was laid on the patient table as an antenna to couple RF from the body coil or was connected to a separate tuned RF pickup coil. A high RF duty-cycle turbo spin-echo pulse sequence excited the wire such that RF energy deposited at the tip of the wire coagulated the protein solution, embolizing the aneurysm. The protein coagulation temperature of 60°C was reached in the aneurysm in ∼12 seconds, yielding a coagulated mass that largely filled the aneurysm. The heating rate was controlled by adjusting pulse-sequence parameters. MR coagulation has the potential to embolize vascular defects by coagulating a protein solution delivered by catheter using MR imaging scanner-induced RF heating of an intracatheter wire. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  2. Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems

    PubMed Central

    Lim, Jaemyung; Tekes, Coskun; Degertekin, F. Levent; Ghovanloo, Maysam

    2016-01-01

    Having intravascular ultrasound (IVUS) imaging capability on guide wires used in cardiovascular interventions may eliminate the need for separate IVUS catheters and expand the use of IVUS in a larger portion of the vasculature. High frequency capacitive micro machined ultrasonic transducer (CMUT) arrays should be integrated with interface electronics and placed on the guide wire for this purpose. Besides small size, this system-on-a-chip (SoC) front-end should connect to the back-end imaging system with a minimum number of wires to preserve the critical mechanical properties of the guide wire. We present a 40 MHz CMUT array interface SoC, which will eventually use only two wires for power delivery and transmits image data using a combination of analog-to-time conversion (ATC) and an impulse radio ultra-wideband (IR-UWB) wireless link. The proof-of-concept prototype ASIC consumes only 52.8 mW and occupies 4.07 mm2 in a 0.35-μm standard CMOS process. A rectifier and regulator power the rest of the SoC at 3.3 V from a 10 MHz power carrier that is supplied through a 2.4 m micro-coax cable with an overall efficiency of 49.1%. Echo signals from an 8-element CMUT array are amplified by a transimpedance amplifier (TIA) array and down-converted to baseband by quadrature sampling using a 40 MHz clock, derived from the power carrier. The ATC generates pulse-width-modulated (PWM) samples at 2 × 10 MS/s with 6 bit resolution, while the entire system achieved 5.1 ENOB. Preliminary images from the prototype system are presented, and alternative data transmission and possible future directions towards practical implementation are discussed. PMID:27662686

  3. Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems.

    PubMed

    Lim, Jaemyung; Tekes, Coskun; Degertekin, F Levent; Ghovanloo, Maysam

    2017-04-01

    Having intravascular ultrasound (IVUS) imaging capability on guide wires used in cardiovascular interventions may eliminate the need for separate IVUS catheters and expand the use of IVUS in a larger portion of the vasculature. High frequency capacitive micro machined ultrasonic transducer (CMUT) arrays should be integrated with interface electronics and placed on the guide wire for this purpose. Besides small size, this system-on-a-chip (SoC) front-end should connect to the back-end imaging system with a minimum number of wires to preserve the critical mechanical properties of the guide wire. We present a 40 MHz CMUT array interface SoC, which will eventually use only two wires for power delivery and transmits image data using a combination of analog-to-time conversion (ATC) and an impulse radio ultra-wideband (IR-UWB) wireless link. The proof-of-concept prototype ASIC consumes only 52.8 mW and occupies 4.07 [Formula: see text] in a 0.35- [Formula: see text] standard CMOS process. A rectifier and regulator power the rest of the SoC at 3.3 V from a 10 MHz power carrier that is supplied through a 2.4 m micro-coax cable with an overall efficiency of 49.1%. Echo signals from an 8-element CMUT array are amplified by a transimpedance amplifier (TIA) array and down-converted to baseband by quadrature sampling using a 40 MHz clock, derived from the power carrier. The ATC generates pulse-width-modulated (PWM) samples at 2 × 10 MS/s with 6 bit resolution, while the entire system achieved 5.1 ENOB. Preliminary images from the prototype system are presented, and alternative data transmission and possible future directions towards practical implementation are discussed.

  4. Method and apparatus for diamond wire cutting of metal structures

    DOEpatents

    Parsells, Robert; Gettelfinger, Geoff; Perry, Erik; Rule, Keith

    2005-04-19

    A method and apparatus for diamond wire cutting of metal structures, such as nuclear reactor vessels, is provided. A diamond wire saw having a plurality of diamond beads with beveled or chamfered edges is provided for sawing into the walls of the metal structure. The diamond wire is guided by a plurality of support structures allowing for a multitude of different cuts. The diamond wire is cleaned and cooled by CO.sub.2 during the cutting process to prevent breakage of the wire and provide efficient cutting. Concrete can be provided within the metal structure to enhance cutting efficiency and reduce airborne contaminants. The invention can be remotely controlled to reduce exposure of workers to radioactivity and other hazards.

  5. Comparison of the Eder-Puestow and Celestin techniques for dilating benign oesophageal strictures.

    PubMed

    Hine, K R; Hawkey, C J; Atkinson, M; Holmes, G K

    1984-10-01

    The Celestin and Eder-Puestow methods of dilating benign oesophageal strictures have been compared prospectively in a randomised trial. One hundred and thirty three dilatations were performed on 72 patients. There was no significant difference between the two techniques with regard to the long term relief of symptoms. Celestin dilatation was quicker, less likely to cause pharyngeal trauma, and less damaging to guide wires. It could not be used, however, in those patients in whom only a short length of guide wire could be passed through the stricture.

  6. Comparison of the Eder-Puestow and Celestin techniques for dilating benign oesophageal strictures.

    PubMed Central

    Hine, K R; Hawkey, C J; Atkinson, M; Holmes, G K

    1984-01-01

    The Celestin and Eder-Puestow methods of dilating benign oesophageal strictures have been compared prospectively in a randomised trial. One hundred and thirty three dilatations were performed on 72 patients. There was no significant difference between the two techniques with regard to the long term relief of symptoms. Celestin dilatation was quicker, less likely to cause pharyngeal trauma, and less damaging to guide wires. It could not be used, however, in those patients in whom only a short length of guide wire could be passed through the stricture. PMID:6479685

  7. Recurrent clot anuria following laparoscopic pyeloplasty in a solitary functioning kidney: managing with double guide wire technique

    PubMed Central

    Kumar, Santosh; Singh, Shivanshu; Parmar, Kalpesh Mahesh; Garg, Nitin

    2014-01-01

    Clot anuria in a solitary functioning kidney is an emergency situation. Haematuria with clot anuria in an early postoperative period represents a challenge, as treatment options are limited. Manipulation of the anastomotic site may lead to anastomotic disruption and urinoma while use of thrombolytic therapy poses the danger of increasing haematuria. We report a case of anuria due to clot retention in the upper tract following laparoscopic dismembered pyeloplasty in a solitary functioning kidney, managed successfully with double guide wire technique. PMID:25540210

  8. Two-year clinical follow-up after pulmonary vein isolation using high-intensity focused ultrasound (HIFU) and an esophageal temperature-guided safety algorithm.

    PubMed

    Neven, Kars; Metzner, Andreas; Schmidt, Boris; Ouyang, Feifan; Kuck, Karl-Heinz

    2012-03-01

    High-intensity frequency ultrasound (HIFU) can achieve pulmonary vein isolation (PVI), but severe complications have happened. An esophageal temperature (ET)-guided safety algorithm was implemented. We investigated medium-term outcome. After left atrial access, HIFU was applied until complete PVI. The safety algorithm was as follows: ≤3 complete ablations per pulmonary vein, early abortion when ET ≥40.0°C, use of Power Modulation at ET >39.0°C or when after 20 to 30 seconds no change in PV electrograms: to reduce the ablation temperature in the surrounding tissue, acoustic power is switched on and off with a frequency of 1 Hz; in all first ablations, use of Power Modulation after 50% of programmed time. Touch-up radiofrequency ablation when PVI failed. Follow-up included interviews and Holter electrocardiograms. Recurrence was defined as atrial fibrillation (AF) >30 seconds without a blanking period. A total of 28 symptomatic patients (18 males, age 63 years), with paroxysmal AF (n = 19) and persistent AF (n = 9) were included. After a median follow-up of 738 days, 22 of the 28 patients (79%) were free of AF without antiarrhythmic drugs. After 1 repeat procedure with radiofrequency ablation, 5 patients remained free of AF. The complications were as follows: 1 lethal atrial-to-esophageal fistula at day 31, 1 pericardial effusion at day 48, 1 unexplained death at day 49, and 2 persistent phrenic nerve palsies with full recovery within 12 months. Two-year follow-up after PVI using HIFU and an ET-guided safety algorithm shows success rates similar to those of radiofrequency-based procedures but with higher complication rates. Importantly, the ET-guided safety algorithm failed to prevent severe complications. HIFU does not meet safety standards required for the treatment of AF, and this led to a halt of its clinical use. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. Strategies for prevention of iatrogenic inferior vena cava filter entrapment and dislodgement during central venous catheter placement.

    PubMed

    Wu, Alex; Helo, Naseem; Moon, Eunice; Tam, Matthew; Kapoor, Baljendra; Wang, Weiping

    2014-01-01

    Iatrogenic migration of inferior vena cava (IVC) filters is a potentially life-threatening complication that can arise during blind insertion of central venous catheters when the guide wire becomes entangled with the filter. In this study, we reviewed the occurrence of iatrogenic migration of IVC filters in the literature and assessed methods for preventing this complication. A literature search was conducted to identify reports of filter/wire entrapment and subsequent IVC filter migration. Clinical outcomes and complications were identified. A total of 38 cases of filter/wire entrapment were identified. All of these cases involved J-tip guide wires. Filters included 23 Greenfield filters, 14 VenaTech filters, and one TrapEase filter. In 18 cases of filter/wire entrapment, there was migration of the filter to the heart and other central venous structures. Retrieval of the migrated filter was successful in only four of the 18 cases, and all of these cases were complicated by strut fracture and distant embolization of fragments. One patient required resuscitation during retrieval. Successful disengagement was possible in 20 cases without filter migration. Iatrogenic migration of an IVC filter is an uncommon complication related to wire/filter entrapment. This complication can be prevented with knowledge of the patient's history, use of proper techniques when placing a central venous catheter, identification of wire entrapment at an early stage, and use of an appropriate technique to disengage an entrapped wire. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  10. Aircraft Crash Survival Design Guide. Volume 4. Aircraft Seats, Restraints, Litters, and Cockpit/Cabin Delethalization

    DTIC Science & Technology

    1989-12-01

    ILLUSTRATIONS (CONTD) 44 Tubular strut wire - bending energy absorber ...... ........... 91 45 Inversion tube concepL with typical force-deformation...expected from a rod-bending sled decelerator and a wire - bending seat load limiter (Refer- ences 35 and 36). Therefore, correcting the calculated...attaching the seat bucket to the rollers, compressive as well as tensile loads can be sustained. Two variations of the wire - bending device have been

  11. Aircraft Crash Survival Design Guide. Volume 4. Aircraft Seats, Restraints. Litters, and Padding

    DTIC Science & Technology

    1980-06-01

    11i 34 Tubular strut wire - bending energy absorber with force-deflection curves ..... . . . . . . . . . . 113 35 Inversion tube concept with...decelera- tor and a wire - bending seat load limiter (References 31 and 32). Therefore, correcting the calculated distance yields 16.25/0.8 - 20.31 in. It...Naval Air Development Center, Warminster, Pennsylvania, October 1969. )- 109 I-. - - ’. Two variations of the wire - bending device have been developed and

  12. Antipilferage Seal User’s Guide

    DTIC Science & Technology

    1997-10-01

    seal is properly installed, ensure that there is no free play between the seal body and the wire. Verify and record the serial number. During post...and Record - Once the seal is properly installed, ensure that there is no free play between the seal body and the wire. During post-mortem...seal is properly installed, ensure that there is no free play between the seal body and the wire. Verify and record the serial number. During post

  13. Building Trades. Carpentry, Electrical Wiring, Plumbing.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Instructional Materials Lab.

    This curriculum guide contains 21 units of self-paced, self-contained instructional materials in the complete building trades curriculum. It is divided into vocational areas of carpentry, electrical wiring, and plumbing. The purpose of the curriculum is to provide minimum skills for disadvantaged and handicapped students entering mainstream…

  14. The Results of Ultrasonography-Guided Percutaneous Radiofrequency Ablation in Hyperparathyroid Patients in Whom Surgery Is Not Feasible

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sormaz, Ismail Cem, E-mail: icsormaz@gmail.com; Poyanlı, Arzu, E-mail: arzupoyanli@yahoo.com; Açar, Sami, E-mail: acarrsami@gmail.com

    BackgroundThe aim of the study was to evaluate the results of ultrasonography (US)-guided percutaneous radiofrequency ablation (RFA) in hyperparathyroid patients who refused surgery or had high surgical risks.Patients and MethodsFive patients with hyperparathyroidism (HPT) underwent US-guided RFA for a single hyperfunctioning parathyroid lesion. Post-ablation serum calcium and parathormone (PTH) assays were performed. All patients underwent imaging studies 6 months after the ablation to visualize the post-ablation change in the size of the treated parathyroid lesions.ResultsAll patients were normocalcemic on the post-ablation 1st day and 6th month. The post-ablation PTH levels were normal in three patients but remained elevated in two patients.more » The size of the parathyroid lesion was ≥30 mm in the two patients with elevated PTH, whereas the lesion was smaller than 30 mm in those with normal post-ablation PTH values.ConclusionAlthough this is a limited case series, it demonstrates the potential feasibility of RFA for HPT. Benefits were achieved particularly in patients with small parathyroid lesions.« less

  15. Laser Guidance in C-Arm Cone-Beam CT-Guided Radiofrequency Ablation of Osteoid Osteoma Reduces Fluoroscopy Time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroes, Maarten W., E-mail: Maarten.Kroes@radboudumc.nl; Busser, Wendy M. H.; Hoogeveen, Yvonne L.

    PurposeTo assess whether laser guidance can reduce fluoroscopy and procedure time of cone-beam computed tomography (CBCT)-guided radiofrequency (RF) ablations of osteoid osteoma compared to freehand CBCT guidance.Materials and Methods32 RF ablations were retrospectively analyzed, 17 laser-guided and 15 procedures using the freehand technique. Subgroup selection of 18 ablations in the hip–pelvic region with a similar degree of difficulty was used for a direct comparison. Data are presented as median (ranges).ResultsComparison of all 32 ablations resulted in fluoroscopy times of 365 s (193–878 s) for freehand and 186 s (75–587 s) for laser-guided procedures (p = 0.004). Corresponding procedure times were 56 min (35–97 min) and 52 min (30–85 min) (p = 0.355).more » The subgroup showed comparable target sizes, needle path lengths, and number of scans between groups. Fluoroscopy times were lower for laser-guided procedures, 215 s (75–413 s), compared to 384 s (193–878 s) for freehand (p = 0.012). Procedure times were comparable between groups, 51 min (30–72 min) for laser guidance and 58 min (35–79 min) for freehand (p = 0.172).ConclusionAdding laser guidance to CBCT-guided osteoid osteoma RF ablations significantly reduced fluoroscopy time without increasing procedure time.Level of EvidenceLevel 4, case series.« less

  16. Therapeutic outcome of CT-guided radiofrequency ablation in patients with osteoid osteoma.

    PubMed

    Lassalle, Louis; Campagna, R; Corcos, G; Babinet, A; Larousserie, F; Stephanazzi, J; Feydy, A

    2017-07-01

    To assess the long-term outcome of computed tomography-guided radiofrequency ablation (CT-guided RFA) in patients with suspected osteoid osteoma (OO). Single-center retrospective study. Patients with clinical suspicion and imaging diagnosis of osteoid osteoma were treated by CT-guided RFA using the same device with either a 7- or 10-mm active tip electrode. Specific precautions were applied in case of articular or spinal OO. Patients were contacted by phone to evaluate the long-term outcome in terms of pain, ability to perform daily activities (including sports), and long-term complications. Success was defined as the absence of residual pain and ability to perform daily activities normally. From 2008 to 2015, 126 patients were treated by CT-guided RFA for OO in our institution. Mean patient age was 26.1 years (SD = 11, range 1-53); mean delay to diagnosis was 16.9 months (SD = 15.2, range 1-120). Among patients who answered the follow-up call (n = 88), the overall success rate was 94.3%: 79/88 (89.8%) had primary success of the procedure, and 4/88 (4.5%) had a secondary success (repeat-RFA after pain recurrence). Mean follow-up time was 34.6 months (SD = 24.7, range 3-90). Few complications occurred: two mild reversible peripheral nerve injuries, one brachial plexus neuropathy, one broken electrode tip fragment, and one muscular hematoma. Osteoid osteoma can be effectively and safely treated by CT-guided RFA using the presented ablation protocol. Beneficial effects of the treatment persist at long-term follow-up.

  17. Augmented reality fluoroscopy simulation of the guide-wire insertion in DHS surgery: A proof of concept study.

    PubMed

    van Duren, B H; Sugand, K; Wescott, R; Carrington, R; Hart, A

    2018-05-01

    Hip fractures contribute to a significant clinical burden globally with over 1.6 million cases per annum and up to 30% mortality rate within the first year. Insertion of a dynamic hip screw (DHS) is a frequently performed procedure to treat extracapsular neck of femur fractures. Poorly performed DHS fixation of extracapsular neck of femur fractures can result in poor mobilisation, chronic pain, and increased cut-out rate requiring revision surgery. A realistic, affordable, and portable fluoroscopic simulation system can improve performance metrics in trainees, including the tip-apex distance (the only clinically validated outcome), and improve outcomes. We developed a digital fluoroscopic imaging simulator using orthogonal cameras to track coloured markers attached to the guide-wire which created a virtual overlay on fluoroscopic images of the hip. To test the accuracy with which the augmented reality system could track a guide-wire, a standard workshop femur was used to calibrate the system with a positional marker fixed to indicate the apex; this allowed for comparison between guide-wire tip-apex distance (TAD) calculated by the system to be compared to that physically measured. Tests were undertaken to determine: (1) how well the apex could be targeted; (2) the accuracy of the calculated TAD. (3) The number of iterations through the algorithm giving the optimal accuracy-time relationship. The calculated TAD was found to have an average root mean square error of 4.2 mm. The accuracy of the algorithm was shown to increase with the number of iterations up to 20 beyond which the error asymptotically converged to an error of 2 mm. This work demonstrates a novel augmented reality simulation of guide-wire insertion in DHS surgery. To our knowledge this has not been previously achieved. In contrast to virtual reality, augmented reality is able to simulate fluoroscopy while allowing the trainee to interact with real instrumentation and performing the procedure on workshop bone models. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Trade Electricity. Signal Wiring--Level 1. Standardized Curriculum.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY. Office of Occupational and Career Education.

    This curriculum guide consists of nine modules on signal wiring, one of the three divisions of the standardized trade electricity curriculum in high schools in New York City. The modules cover the following subjects: bells, double contact pushbuttons, annunciator circuits, open circuit burglar alarms, closed circuit burglar alarms, fire alarms,…

  19. Preliminary Experience with use of Qureshi-5 Catheters for Diagnostic Cerebral Angiography

    PubMed Central

    Qureshi, Adnan I.; Yan, Xiao; Liu, HongLiang

    2015-01-01

    BACKGROUND A catheter technique was developed to overcome current challenges in the stabilization and manipulation of catheter in tortuous arteries such as right subclavian artery and left common carotid artery. METHODS The new catheter has the following two lumens: first lumen can accommodate a 0.035-inch guide wire (lumen A) and a curved shape at the distal end; the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen (lumen B). The catheter is withdrawn or advanced over the 0.018-inch guide wire and the curved free end of catheter manipulated until the end engages the origin of the target artery. Subsequently, either contrast can be injected or a 0.035-inch guide wire advanced into the target artery. RESULTS The catheters were used in two patients to perform diagnostic cerebral angiography through a 6F introducer sheath placed in the right common femoral artery. The left and right common carotid arteries and left and right vertebral arteries were catheterized in first patient (contrast used 50 ml; fluoroscopy time 20:09 min). The left and right internal carotid arteries, left and right subclavian arteries, and left external carotid artery were catheterized in second patient (contrast used 40 ml; fluoroscopy time 13:56 min). No complications were observed in either of the two patients. CONCLUSIONS The performance of the new catheter for catheterization of multiple arteries in two patients was considered adequate with high-quality angiographic image acquisitions. PMID:26060529

  20. A multiplanar complex resection of a low-grade chondrosarcoma of the distal femur guided by K-wires previously inserted under CT-guide: a case report

    PubMed Central

    2014-01-01

    Background In muscular skeletal oncology aiming to achieve wide surgical margin is one of the main factors influencing patient prognosis. In cases where lesions are either meta or epiphyseal, surgery most often compromises joint integrity and stability because muscles, tendons and ligaments are involved in wide resection. When lesions are well circumscribed they can be completely resected by performing multi-planar osteotomies guided by computer-assisted navigation. We describe a case of low-grade chondrosarcoma of the distal femur where a simple but effective technique was useful to perform complex multiplanar osteotomies. No similar techniques are reported in the literature. Case presentation A 57 year-old Caucasian female was referred to our department for the presence of a distal femur chondrosarcoma. A resection with the presenting technique was scheduled. The first step consists of inserting several K-wires under CT-scan control to delimitate the tumor; the second step consists of tumor removal: in operative theatre, following surgical access, k-wires are used as guide positioning; scalpels are externally placed to k-wires to perform a safe osteotomy. Conclusions Computed assisted resections can be considered the most advantageous method to reach the best surgical outcome; unfortunately navigation systems are only available in specialized centres. The present technique allows for a multiplanar complex resection when navigation systems are not available. This technique can be applied in low-grade tumours where a minimal wide margin can be considered sufficient. PMID:25123066

  1. Validation of a technique for accurate fine-wire electrode placement into posterior gluteus medius using real-time ultrasound guidance.

    PubMed

    Hodges, P W; Kippers, V; Richardson, C A

    1997-01-01

    Fine-wire electromyography is primarily utilised for the recording of activity of the deep musculature, however, due to the location of these muscles, accurate electrode placement is difficult. Real-time ultrasound imaging (RTUI) of muscle tissue has been used for the guidance of the needle insertion for the placement of electrodes into the muscles of the abdominal wall. The validity of RTUI guidance of needle insertion into the deep muscles has not been determined. A cadaveric study was conducted to evaluate the accuracy with which RTUI can be used to guide fine-wire electrode placement using the posterior fibres of gluteus medius (PGM) as an example. Pilot studies revealed that the ultrasound resolution of cadaveric tissue is markedly reduced making it impossible to directly evaluate the technique, therefore, three studies were conducted. An initial study involved the demarcation of the anatomical boundaries of PGM using RTUI to define a technique based on an anatomical landmark that was consisent with the in vivo RTUI guided needle placement technique. This anatomical landmark was then used as the guide for the cadaveric needle insertion. Once the needle was positioned 0.05 ml of dye was introduced and the specimen dissected. The dye was accurately placed in PGM in 100% of the specimens. Finally, fine-wire electrodes were inserted into the PGM of five volunteers and manoeuvres performed indicating the accuracy of placement. This study supports the use of ultrasound imaging for the accurate guidance of needle insertion for fine-wire and needle EMG electrodes.

  2. Percutaneous Radiofrequency Ablation of a Small Renal Mass Complicated by Appendiceal Perforation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boone, Judith, E-mail: j.boone@amc.uva.nl; Bex, Axel, E-mail: a.bex@nki.nl; Prevoo, Warner, E-mail: w.prevoo@nki.nl

    2012-06-15

    Percutaneous radiofrequency ablation (RFA) has gained wide acceptance as nephron-sparing therapy for small renal masses in select patients. Generally, it is a safe procedure with minor morbidity and acceptable short-term oncologic outcome. However, as a result of the close proximity of vital structures, such as the bowel, ureter, and large vessels, to the ablative field, complications regarding these structures may occur. This is the first article describing appendiceal perforation as a complication of computed tomography-guided RFA despite hydrodissection. When performing this innovative and promising procedure one should be aware of the possibility of particular minor and even major complications.

  3. Radiofrequency Ablation of Uterine Fibroids: a Review.

    PubMed

    Lee, Bruce B; Yu, Steve P

    2016-01-01

    Laparoscopic, ultrasound-guided radiofrequency ablation (RFA) is a new, FDA-cleared uterine sparing, outpatient procedure for uterine fibroids. The procedure utilizes recent technological advancements in instrumentation and imaging, allowing surgeons to treat numerous fibroids of varying size and location in a minimally invasive fashion. Early and mid-term data from multi-center clinical trials have demonstrated safety and efficacy, with resolution or improvement of symptoms and significant volume reduction. Re-intervention rates for fibroid symptoms have been low. The procedure is well tolerated with a typically uneventful and rapid recovery requiring NSAIDs only for postoperative pain. While post RFA pregnancy data are limited, the results are promising.

  4. Online C-arm calibration using a marked guide wire for 3D reconstruction of pulmonary arteries

    NASA Astrophysics Data System (ADS)

    Vachon, Étienne; Miró, Joaquim; Duong, Luc

    2017-03-01

    3D reconstruction of vessels from 2D X-ray angiography is highly relevant to improve the visualization and the assessment of vascular structures such as pulmonary arteries by interventional cardiologists. However, to ensure a robust and accurate reconstruction, C-arm gantry parameters must be properly calibrated to provide clinically acceptable results. Calibration procedures often rely on calibration objects and complex protocol which is not adapted to an intervention context. In this study, a novel calibration algorithm for C-arm gantry is presented using the instrumentation such as catheters and guide wire. This ensures the availability of a minimum set of correspondences and implies minimal changes to the clinical workflow. The method was evaluated on simulated data and on retrospective patient datasets. Experimental results on simulated datasets demonstrate a calibration that allows a 3D reconstruction of the guide wire up to a geometric transformation. Experiments with patients datasets show a significant decrease of the retro projection error to 0.17 mm 2D RMS. Consequently, such procedure might contribute to identify any calibration drift during the intervention.

  5. [Clinical study on the coronary artery interventions guided by the magnetic navigation system].

    PubMed

    Li, Chun-jian; Wang, Hui; Wang, Lian-sheng; Zhu, Tie-bing; Yang, Zhi-jian; Cao, Ke-jiang

    2010-03-01

    To investigate the efficacy and safety of the magnetic navigation system used in the real world percutaneous coronary artery intervention. All lesions detected by the coronary artery angiography in the magnetic-navigation catheter lab indicated for percutaneous coronary artery intervention (PCI) were included and treated under the guidance of the magnetic navigation system. The characteristics of the target lesion, process of the procedure, time and dosage of the X-ray exposure, and procedure-related complication were recorded and analyzed. One hundred and twenty one patients with 138 lesions were recruited and intervened by PCI during the period from April 2006 to June 2008. Thirty lesions were classified as type A, 50 as type B1, 36 as type B2, 22 as type C (including seven total occlusions). The average stenosis of the target lesions was (85.3 +/- 10.0)%, mean length was (21.1 +/- 10.0) mm. Under the guidance of the magnetic navigation system, 134 target lesions were passed by the magnetic guide-wires, the lesion passing ratio was 97.1%. The X-ray exposure time, X-ray dosage and the contrast volume used during the period of the wire placement were (55.9 +/- 35.4) seconds, (98.0 +/- 86.1) mGy/(490.0 +/- 422.2) microGym(2) and (8.0 +/- 5.4) ml, respectively. A total of 164 stents were implanted in the vessels where the target lesions were passed by the magnetic wires. There was no magnetic navigation system associated complication. Magnetic guide-wires failed to pass four target lesions, two of which were chronic total occlusions (CTOs), and the other two were calcified subtotal occlusions. It is feasible and safe to adopt the magnetic navigation system for the real-world coronary artery intervention. The magnetic guide-wire possesses a high lesion-passing ratio. The CTOs and calcified subtotal occlusions are not ideal lesions for use of the magnetic navigation system.

  6. Therapy of Pancreatic Neuroendocrine Tumors: Fine Needle Intervention including Ethanol and Radiofrequency Ablation

    PubMed Central

    Lakhtakia, Sundeep

    2017-01-01

    Pancreatic neuroendocrine tumors (PNETs) are increasingly being detected, though usually as incidental findings. Majority of the PNETs are non-functional and surgical resection is the standard of care for most of them. However, in patients with small PNETs localized within the pancreas, who are unfit or unwilling for surgery, alternate methods of treatment are needed. Direct methods of ablation of PNETs, using either ethanol injection or radiofrequency ablation (RFA), are emerging as effective methods. The limited literature available as case reports or case series on endoscopic ultrasound (EUS)-guided local ablation using either ethanol or RFA has demonstrated safety and efficacy along with short- to medium-term sustained relief. Long-term benefits with these local ablative therapies are awaited. Comparative studies are needed to show which of these two competing technologies is superior. Finally, comparative trials of EUS-guided ablation with surgical resection in terms of efficacy and safety will ensure their place in the management algorithm. PMID:29207860

  7. Remote Magnetic versus Manual Navigation for Radiofrequency Ablation of Paroxysmal Atrial Fibrillation: Long-Term, Controlled Data in a Large Cohort.

    PubMed

    Kataria, Vikas; Berte, Benjamin; Vandekerckhove, Yves; Tavernier, Rene; Duytschaever, Mattias

    2017-01-01

    Purpose. We aimed to study long-term outcome after pulmonary vein isolation (PVI) guided by remote magnetic navigation (RMN) and provided comparative data to outcome after manual navigation (MAN). Methods. Three hundred thirty-six patients with symptomatic paroxysmal AF underwent PVI by irrigated point-by-point radiofrequency (RF) ablation (RMN, n = 114 versus MAN, n = 222). Patients were followed up with symptom guided rhythm monitoring for a period up to 43 months. The end point of the study was freedom from repeat ablation after a single procedure and without antiarrhythmic drug treatment (ADT). Results. At the end of follow-up (median 26.3 months), freedom from repeat ablation was comparable between RMN and MAN (70.9% versus 69.5%, p = 0.61). At repeat, mean number of reconnected veins was 2.4 ± 1.2 in RMN versus 2.6 ± 1.0 in MAN ( p = 0.08). The majority of repeat procedures occurred during the first year (82.1% in RMN versus 78.5% in MAN; p = 0.74). Conclusion. On the long term (up to 3 years) and in a large cohort of patients with paroxysmal AF, RMN-guided PVI is as effective as MAN guided PVI. In both strategies the majority of repeat procedures occurred during the first year after index procedure.

  8. Remote Magnetic versus Manual Navigation for Radiofrequency Ablation of Paroxysmal Atrial Fibrillation: Long-Term, Controlled Data in a Large Cohort

    PubMed Central

    Berte, Benjamin; Vandekerckhove, Yves; Tavernier, Rene

    2017-01-01

    Purpose. We aimed to study long-term outcome after pulmonary vein isolation (PVI) guided by remote magnetic navigation (RMN) and provided comparative data to outcome after manual navigation (MAN). Methods. Three hundred thirty-six patients with symptomatic paroxysmal AF underwent PVI by irrigated point-by-point radiofrequency (RF) ablation (RMN, n = 114 versus MAN, n = 222). Patients were followed up with symptom guided rhythm monitoring for a period up to 43 months. The end point of the study was freedom from repeat ablation after a single procedure and without antiarrhythmic drug treatment (ADT). Results. At the end of follow-up (median 26.3 months), freedom from repeat ablation was comparable between RMN and MAN (70.9% versus 69.5%, p = 0.61). At repeat, mean number of reconnected veins was 2.4 ± 1.2 in RMN versus 2.6 ± 1.0 in MAN (p = 0.08). The majority of repeat procedures occurred during the first year (82.1% in RMN versus 78.5% in MAN; p = 0.74). Conclusion. On the long term (up to 3 years) and in a large cohort of patients with paroxysmal AF, RMN-guided PVI is as effective as MAN guided PVI. In both strategies the majority of repeat procedures occurred during the first year after index procedure. PMID:28386560

  9. [Percutaneous radiofrequency ablation of osteoid osteomas: technique and results].

    PubMed

    Bruners, P; Penzkofer, T; Günther, R W; Mahnken, A

    2009-08-01

    Osteoid osteoma is a benign primary bone tumor that typically occurs in children and young adults. Besides local pain, which is often worse at night, prompt relief due to medication with acetylsalicylic acid (ASS) is characteristic for this bone lesion. Because long-term medication with ASS does not represent an alternative treatment strategy due to its potentially severe side effects, different minimally invasive image-guided techniques for the therapy of osteoid osteoma have been developed. In this context radiofrequency (RF) ablation in particular has become part of the clinical routine. The technique and results of image-guided RF ablation are compared to alternative treatment strategies. Using this technique, an often needle-shaped RF applicator is percutaneously placed into the tumor under image guidance. Then a high-frequency alternating current is applied by the tip of the applicator which leads to ionic motion within the tissue resulting in local heat development and thus in thermal destruction of the surrounding tissue including the tumor. The published primary and secondary success rates of this technique are 87 and 83 %, respectively. Surgical resection and open curettage show comparable success rates but are associated with higher complication rates. In addition image-guided RF ablation of osteoid osteomas is associated with low costs. In conclusion image-guided RF ablation can be considered the gold standard for the treatment of osteoid osteoma.

  10. Advanced signal processing methods applied to guided waves for wire rope defect detection

    NASA Astrophysics Data System (ADS)

    Tse, Peter W.; Rostami, Javad

    2016-02-01

    Steel wire ropes, which are usually composed of a polymer core and enclosed by twisted wires, are used to hoist heavy loads. These loads are different structures that can be clamshells, draglines, elevators, etc. Since the loading of these structures is dynamic, the ropes are working under fluctuating forces in a corrosive environment. This consequently leads to progressive loss of the metallic cross-section due to abrasion and corrosion. These defects can be seen in the forms of roughened and pitted surface of the ropes, reduction in diameter, and broken wires. Therefore, their deterioration must be monitored so that any unexpected damage or corrosion can be detected before it causes fatal accident. This is of vital importance in the case of passenger transportation, particularly in elevators in which any failure may cause a catastrophic disaster. At present, the widely used methods for thorough inspection of wire ropes include visual inspection and magnetic flux leakage (MFL). Reliability of the first method is questionable since it only depends on the operators' eyes that fails to determine the integrity of internal wires. The later method has the drawback of being a point by point and time-consuming inspection method. Ultrasonic guided wave (UGW) based inspection, which has proved its capability in inspecting plate like structures such as tubes and pipes, can monitor the cross-section of wire ropes in their entire length from a single point. However, UGW have drawn less attention for defect detection in wire ropes. This paper reports the condition monitoring of a steel wire rope from a hoisting elevator with broken wires as a result of corrosive environment and fatigue. Experiments were conducted to investigate the efficiency of using magnetostrictive based UGW for rope defect detection. The obtained signals were analyzed by two time-frequency representation (TFR) methods, namely the Short Time Fourier Transform (STFT) and the Wavelet analysis. The location of the defect and its severity were successfully identified and characterized.

  11. Antenna coupling--a novel mechanism of radiofrequency electrosurgery complication: practical implications.

    PubMed

    Robinson, Thomas N; Barnes, Kelli S; Govekar, Henry R; Stiegmann, Greg V; Dunn, Christina L; McGreevy, Francis T

    2012-08-01

    (1) To determine if antenna coupling occurs in common operating room scenarios. (2) To define modifiable clinical variables that reduce the magnitude of antenna coupling. Mechanisms of electrosurgical burns where monitoring devices contact the surgical patient are unclear. Antenna coupling occurs when the "bovie" active electrode (electrically active transmitting antenna) emits energy, which is captured by a nonelectrically active wire (electrically inactive receiving antenna) in close proximity without direct contact. Monopolar radiofrequency energy was delivered to a laparoscopic instrument (electrically active transmitting antenna), whereas other nonelectrically active wires (electrically inactive receiving antenna) including electrocardiogram (EKG) lead, nonactive "bovie" pencil, and nerve electrode monitor were placed in proximity. Temperature changes of tissue placed adjacent to the electrically inactive receiving antennae were measured. Nonelectrically active wires (receiving antenna) increase tissue temperature when lying parallel to the active electrode cord: EKG pad 2.4°C ± 1.2°C (P = 0.002), "bovie" pencil tip 90°C ± 9°C (P < 0.001), and nerve electrode monitor 106°C ± 12°C (P < 0.001). Factors that reduced the heat generated by antenna coupling included the following: increasing angulation between transmitting and receiving antennae (parallel = 90°C ± 9°C; 45° angle = 53°C ± 10°C; perpendicular = 35°C ± 11°C; P < .001), increasing separation distance between parallel transmitting and receiving antenna (<1 cm = 90°C ± 9°C; 15 cm = 44°C ± 18°C; 30 cm = 39°C ± 2°C; P < .001); and decreasing generator power setting (15 W = 59°C ± 11°C; 30 W = 90°C ± 9°C; 45 W = 98°C ± 8°C; P < .001). Antenna coupling occurs in common operating room scenarios. Simple, practical measures by the surgeon, such as orienting the receiving antenna at a greater angle and with greater separation to the active electrode cord, or lowering the generator power setting reduce antenna coupling.

  12. Use of Multiple Operatories in Dental Care Delivery.

    DTIC Science & Technology

    1982-02-01

    07212 Repair Traumatic Wounds, Complex Under 5cm 2.6 07213 Repair Traumatic Wounds, Complex Over 5cm 5.3 07260 Cleft Palate Repair 10.6 07265 Cleft Lip ...Facial Prosthesis 18.5 05940 Implants 16.8 05950 Maxillary Inclined Plane or Occlusal Table 19.4 05955 Mandibular Guide Flange 16.8 05960 Palatal Lift...Passive Lingual or Palatal Wire 1.2 08446 Face Bow, J Hooks, Clinical Cup 1.2 08447 Active Lingual or Palatal Wire 1.2 08448 Multi-Stranded Wire 0.6 08510

  13. Fabrication of a smart air intake structure using shape memory alloy wire embedded composite

    NASA Astrophysics Data System (ADS)

    Jung, Beom-Seok; Kim, Min-Saeng; Kim, Ji-Soo; Kim, Yun-Mi; Lee, Woo-Yong; Ahn, Sung-Hoon

    2010-05-01

    Shape memory alloys (SMAs) have been actively studied in many fields utilizing their high energy density. Applying SMA wire-embedded composite to aerospace structures, such as air intake of jet engines and guided missiles, is attracting significant attention because it could generate a comparatively large actuating force. In this research, a scaled structure of SMA wire-embedded composite was fabricated for the air intake of aircraft. The structure was composed of several prestrained Nitinol (Ni-Ti) SMA wires embedded in ∩-shape glass fabric reinforced plastic (GFRP), and it was cured at room temperature for 72 h. The SMA wire-embedded GFRP could be actuated by applying electric current through the embedded SMA wires. The activation angle generated from the composite structure was large enough to make a smart air intake structure.

  14. Stereo electroencephalography-guided radiofrequency thermocoagulation (SEEG-guided RF-TC) in drug-resistant focal epilepsy: Results from a 10-year experience.

    PubMed

    Bourdillon, Pierre; Isnard, Jean; Catenoix, Hélène; Montavont, Alexandra; Rheims, Sylvain; Ryvlin, Philippe; Ostrowsky-Coste, Karine; Mauguiere, François; Guénot, Marc

    2017-01-01

    Stereo electroencephalography (SEEG)-guided radiofrequency thermocoagulation (SEEG-guided RF-TC) has been proposed since 2004 as a possible treatment of some focal drug-resistant epilepsy. The aim of this study is to provide extensive data about efficacy and safety of SEEG-guided RF-TC. Over a 10-year period, 162 patients with drug-resistant focal epilepsy were eligible for SEEG-guided RF-TG during phase II invasive investigation by SEEG. All follow-up and safety data were collected prospectively. The primary outcome was seizure freedom at 2 months and at 1 year after SEEG-guided RF-TC. Secondary outcomes were the responders' rate (patient with at least 50% decrease in seizure frequency) and their long-term follow-up. Twenty-five percent of patients were seizure-free at 2 months and 7% at 1 year. We reported 67% of responders at 2 months and 48% at 1 year; 58% of responders maintained their status during the long-term follow-up. The seizure outcome was significantly better when the SEEG-guided RF-TC involved the occipital region (p = 0.007). When surgery followed an SEEG-guided RF-TC, the positive predictive value of being a responder 2 months after an SEEG-guided RF-TC and to be Engel's class I or II after surgery was 93%. We reported 1.1% of permanent deficit and 2.4% of transient side effects. Our results, gathered in a large population over a 10-year period, confirm that SEEG-guided RF-TC is a safe technique, being efficient in many cases. More than two thirds of patients showed a short-term improvement, and almost half of them were responders at 1-year follow-up. The technique appears to be especially interesting for limited epileptic zone inaccessible to surgery and when epilepsy is related to a large unilateral network (network disruption by multiple RF-TC). Furthermore, SEEG-guided RF-TC effect is a predictor of outcome after conventional cortectomy in patients eligible for surgery. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  15. Error sources affecting thermocouple thermometry in RF electromagnetic fields.

    PubMed

    Chakraborty, D P; Brezovich, I A

    1982-03-01

    Thermocouple thermometry errors in radiofrequency (typically 13, 56 MHZ) electromagnetic fields such as are encountered in hyperthermia are described. RF currents capacitatively or inductively coupled into the thermocouple-detector circuit produce errors which are a combination of interference, i.e., 'pick-up' error, and genuine rf induced temperature changes at the junction of the thermocouple. The former can be eliminated by adequate filtering and shielding; the latter is due to (a) junction current heating in which the generally unequal resistances of the thermocouple wires cause a net current flow from the higher to the lower resistance wire across the junction, (b) heating in the surrounding resistive material (tissue in hyperthermia), and (c) eddy current heating of the thermocouple wires in the oscillating magnetic field. Low frequency theories are used to estimate these errors under given operating conditions and relevant experiments demonstrating these effects and precautions necessary to minimize the errors are described. It is shown that at 13.56 MHz and voltage levels below 100 V rms these errors do not exceed 0.1 degrees C if the precautions are observed and thermocouples with adequate insulation (e.g., Bailey IT-18) are used. Results of this study are being currently used in our clinical work with good success.

  16. Laparoscopic vs computerized tomography-guided radiofrequency ablation for large hepatic hemangiomas abutting the diaphragm

    PubMed Central

    Gao, Jun; Kong, Jian; Ding, Xue-Mei; Ke, Shan; Niu, Hai-Gang; Xin, Zong-Hai; Ning, Chun-Min; Guo, Shi-Gang; Li, Xiao-Long; Zhang, Long; Dong, Yong-Hong; Sun, Wen-Bing

    2015-01-01

    AIM: To compare safety and therapeutic efficacy of laparoscopic radiofrequency (RF) ablation vs computed tomography (CT)-guided RF ablation for large hepatic hemangiomas abutting the diaphragm. METHODS: We retrospectively reviewed our sequential experience of treating 51 large hepatic hemangiomas abutting the diaphragm in 51 patients by CT-guided or laparoscopic RF ablation due to either the presence of symptoms and/or the enlargement of hemangioma. Altogether, 24 hemangiomas were ablated via a CT-guided percutaneous approach (CT-guided ablation group), and 27 hemangiomas were treated via a laparoscopic approach (laparoscopic ablation group). RESULTS: The mean diameter of the 51 hemangiomas was 9.6 ± 1.8 cm (range, 6.0-12.0 cm). There was no difference in the diameter of hemangiomas between the two groups (P > 0.05). RF ablation was performed successfully in all patients. There was no difference in ablation times between groups (P > 0.05). There were 23 thoracic complications in 17 patients: 15 (62.5%, 15/24) in the CT-guided ablation group and 2 (7.4%, 2/27) in the laparoscopic ablation group (P < 0.05). According to the Dindo-Clavien classification, two complications (pleural effusion and diaphragmatic rupture grade III) were major in two patients. All others were minor (grade I). Both major complications occurred in the CT-guided ablation group. The minor complications were treated successfully with conservative measures, and the two major complications underwent treatment by chest tube drainage and thoracoscopic surgery, respectively. Complete ablation was achieved in 91.7% (22/24) and 96.3% (26/27) in the CT-guided and the laparoscopic ablation groups, respectively (P > 0.05). CONCLUSION: Laparoscopic RF ablation therapy should be used as the first-line treatment option for large hepatic hemangiomas abutting the diaphragm. It avoids thermal injury to the diaphragm and reduces thoracic complications. PMID:26019459

  17. Prospective motion correction using inductively coupled wireless RF coils.

    PubMed

    Ooi, Melvyn B; Aksoy, Murat; Maclaren, Julian; Watkins, Ronald D; Bammer, Roland

    2013-09-01

    A novel prospective motion correction technique for brain MRI is presented that uses miniature wireless radio-frequency coils, or "wireless markers," for position tracking. Each marker is free of traditional cable connections to the scanner. Instead, its signal is wirelessly linked to the MR receiver via inductive coupling with the head coil. Real-time tracking of rigid head motion is performed using a pair of glasses integrated with three wireless markers. A tracking pulse-sequence, combined with knowledge of the markers' unique geometrical arrangement, is used to measure their positions. Tracking data from the glasses is then used to prospectively update the orientation and position of the image-volume so that it follows the motion of the head. Wireless-marker position measurements were comparable to measurements using traditional wired radio-frequency tracking coils, with the standard deviation of the difference < 0.01 mm over the range of positions measured inside the head coil. Wireless-marker safety was verified with B1 maps and temperature measurements. Prospective motion correction was demonstrated in a 2D spin-echo scan while the subject performed a series of deliberate head rotations. Prospective motion correction using wireless markers enables high quality images to be acquired even during bulk motions. Wireless markers are small, avoid radio-frequency safety risks from electrical cables, are not hampered by mechanical connections to the scanner, and require minimal setup times. These advantages may help to facilitate adoption in the clinic. Copyright © 2013 Wiley Periodicals, Inc.

  18. Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting.

    PubMed

    Matsui, Yusuke; Hiraki, Takao; Gobara, Hideo; Iguchi, Toshihiro; Fujiwara, Hiroyasu; Kawabata, Takahiro; Yamauchi, Takatsugu; Yamaguchi, Takuya; Kanazawa, Susumu

    2016-06-01

    Computed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking. Radiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator's finger skin was measured using thermoluminescent dosimeter rings. The mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator's finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA. Radiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.

  19. Soft J-tipped guide wire-induced cardiac perforation in a patient with right ventricular lipomatosis and wall thinning.

    PubMed

    Hiroshima, Yuki; Tajima, Katsushi; Shiono, Yousuke; Suzuki, Ikuko; Kohno, Kei; Kato, Yuichi; Shunji, Kawamura; Kato, Takeo

    2012-01-01

    Cardiac tamponade caused by perforation is a rare but potentially lethal complication of central venous catheter (CVC) insertion. We herein report a case of cardiac perforation associated with the use of a soft J-tipped guide wire. Twenty minutes after the insertion of a CVC, the patient developed unexpected cardiac arrest. An autopsy revealed 400 mL of pericardial blood. The right ventricular wall was 1 mm thick with about 10 myocyte layers, which is one-third that of the normal heart. A histological analysis revealed widespread fatty infiltration of the right ventricular wall (right ventricular lipomatosis).

  20. Micromachined actuators/sensors for intratubular positioning/steering

    DOEpatents

    Lee, Abraham P.; Krulevitch, Peter A.; Northrup, M. Allen; Trevino, Jimmy C.

    1998-01-01

    Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems.

  1. Microvalve

    DOEpatents

    Lee, A.P.; Krulevitch, P.A.; Northrup, M.A.; Trevino, J.C.

    1998-10-13

    Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems. 14 figs.

  2. Microvalve

    DOEpatents

    Lee, Abraham P.; Krulevitch, Peter A.; Northrup, M. Allen; Trevino, Jimmy C.

    1998-01-01

    Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems.

  3. Predictors of chronic pulmonary vein reconnections after contact force-guided ablation: importance of completing electrical isolation with circumferential lines and creating sufficient ablation lesion densities.

    PubMed

    Nakamura, Kohki; Naito, Shigeto; Sasaki, Takehito; Minami, Kentaro; Take, Yutaka; Shimizu, Satoru; Yamaguchi, Yoshiaki; Yano, Toshiaki; Senga, Michiharu; Yamashita, Eiji; Sugai, Yoshinao; Kumagai, Koji; Funabashi, Nobusada; Oshima, Shigeru

    2016-12-01

    We aimed to identify the predictors of chronic pulmonary vein reconnections (CPVRs) after contact force (CF)-guided circumferential PV isolation (CPVI) of atrial fibrillation (AF). Forty-nine consecutive patients undergoing second ablation procedures for recurrent AF after CF-guided ablation were retrospectively studied. The CPVI was performed by point-by-point ablation with a target CF of 15-20 g. The incidence of CPVRs was evaluated along the right- and left-sided anterior and posterior CPVI regions (Ant-RPVs, Post-RPVs, Ant-LPVs, and Post-LPVs). CPVRs were observed in 30.6, 22.4, 20.4, and 32.7 % of patients along the Ant-RPVs, Post-RPVs, Ant-LPVs, and Post-LPVs, respectively (P = 0.436). In the multivariate logistic analyses, completing a left atrium-PV conduction block with touch-up ablation inside the initially estimated CPVI lines (Ant-RPVs, Post-RPVs, Ant-LPVs, Post-LPVs; odds ratio [OR] 5.747, 15.000, 207.619, 7.940; P = 0.032, 0.004, 0.034, 0.021) and region length (Post-LPVs; OR 3.183, P = 0.027) were positive predictors of CPVRs, while the mean CF (Ant-RPVs; OR 0.861, P = 0.045) and number of radiofrequency applications per unit length (Ant-LPVs, Post-LPVs; OR 0.038, 0.122; P = 0.034, 0.029) were negative predictors. At optimal cutoffs of 5.8 cm for the region length, 14.2 g for the mean CF, and 1.97/cm (Ant-LPVs) and 2.01/cm (Post-LPVs) for the radiofrequency application density, the sensitivity and specificity were 93.8 and 63.6 %, 60.0 and 76.5 %, 90.0 and 64.1 %, and 75.0 and 63.6 %, respectively. Completing PVI with circumferential lines without touch-up ablation and creating a sufficient density of radiofrequency ablation lesions on the lines with a sufficient CF may be necessary to prevent CPVRs after a CF-guided CPVI.

  4. Ultrasound-Guided Pulsed Radiofrequency Stimulation of Posterior Tibial Nerve: A Potential Novel Intervention for Recalcitrant Plantar Fasciitis.

    PubMed

    Wu, Yung-Tsan; Chang, Chih-Ya; Chou, Yu-Ching; Yeh, Chun-Chang; Li, Tsung-Ying; Chu, Heng-Yi; Chen, Liang-Cheng

    2017-05-01

    To evaluate the therapeutic benefit of ultrasound-guided pulsed radiofrequency (PRF) stimulation at the posterior tibial nerve (PTN) in patients with recalcitrant plantar fasciitis (PF). A prospective, randomized, double-blinded, placebo-controlled trial (12-wk follow-up). Outpatient local medical center settings. Patients (N=36) with recalcitrant PF underwent randomization, and all were included in the final data analysis. Patients in the PRF group were treated with 1 dose of ultrasound-guided PRF stimulation at the PTN, and those in the control group received 1 dose of 2% lidocaine, 0.5mL, injected at the PTN under ultrasound guidance. The visual analog scale (first-step and overall pain), American Orthopedic Foot-Ankle Society (AOFAS) ankle-hindfoot scale, and ultrasonographic thickness of the plantar fascia were evaluated at 1, 4, 8, and 12 weeks after treatment. Thirty-six patients (20 feet per group) completed the study. The PRF group had a significantly larger improvement in first-step pain, overall pain, and AOFAS score (all P<.001), as well as plantar fascia thickness (P<.05), compared with those of the control group at all observed time points. This study shows that ultrasound-guided PRF stimulation at the PTN is effective for treating recalcitrant PF. This simple, reproducible method could be a novel strategy for managing recalcitrant PF. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Diaphragm Pacing.

    PubMed

    DiMarco, Anthony F

    2018-06-01

    Diaphragm pacing (DP) is a useful and cost-effective alternative to mechanical ventilation in patients with ventilator-dependent spinal cord injury and central hypoventilation syndrome. Patients with SCI should be carefully screened to assess the integrity of their phrenic nerves. In eligible patients, DP improves mobility, speech, olfaction, and quality of life. The stigma of being attached to a mechanical device and risk of ventilator disconnection are eliminated. There is also some evidence that DP results in a reduction in the rate of respiratory tract infections. DP is associated with infrequent side effects and complications, such as wire breakage, radiofrequency failure, and infection. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Susceptibility cancellation of a microcoil wound with a paramagnetic-liquid-filled copper capillary

    NASA Astrophysics Data System (ADS)

    Takeda, Kazuyuki; Takasaki, Tomoya; Takegoshi, K.

    2015-09-01

    Even though microcoils improve the sensitivity of NMR measurement of tiny samples, magnetic-field inhomogeneity due to the bulk susceptibility effect of the coil material can cause serious resonance-line broadening. Here, we propose to fabricate the microcoil using a thin, hollow copper capillary instead of a wire and fill paramagnetic liquid inside the capillary, so as to cancel the diamagnetic contribution of the copper. Susceptibility cancellation is demonstrated using aqueous solution of NiSO4. In addition, the paramagnetic liquid serves as coolant when it is circulated through the copper capillary, effectively transferring the heat generated by radiofrequency pulses.

  7. Antenna coupling explains unintended thermal injury caused by common operating room monitoring devices.

    PubMed

    Townsend, Nicole T; Jones, Edward L; Paniccia, Alessandro; Vandervelde, Joel; McHenry, Jennifer R; Robinson, Thomas N

    2015-04-01

    Unintended thermal injury from patient monitoring devices (eg, electrocardiogram pads, neuromonitoring leads) results in third-degree burns. A mechanism for these injuries is not clear. The monopolar "bovie" emits radiofrequency energy that transfers to nearby, nonelectrically active cables or wires without direct contact by capacitive and antenna coupling. The purpose of this study was to determine if, and to what extent, radiofrequency energy couples to common patient monitoring devices. In an ex vivo porcine model, monopolar radiofrequency energy was delivered to a handheld "bovie" pencil. Nonelectrically active neuromonitoring and cardiac-monitoring leads were placed in proximity to the monopolar pencil and its cord. Temperature changes of tissue touched by the monitoring lead were measured using a thermal camera immediately after a 5-second activation. The energy-device cords were then separated by 15 cm, the power was reduced from 30 W coag to 15 W coag and different cord angulation was tested. An advanced bipolar device, a plasma-based device, and an ultrasonic device were also tested at standard settings. The neuromonitoring lead increased tissue temperature at the insertion site by 39 ± 13°C (P<0.001) creating visible char at the skin. The electrocardiogram lead raised tissue temperature by 1.3 ± 0.5°C (P<0.001). Decreasing generator power from 30 W to 15 W and separating the bovie cord from the neuromonitoring cord by 15 cm significantly reduced the temperature change (39 ± 13°C vs. 26±5°C; P<0.001 and 39 ± 13°C vs. 10 ± 5°C; P<0.001, respectively). Lastly, monopolar energy increased tissue temperatures significantly more than argon beam energy (34 ± 15°C), advanced bipolar energy (0.2 ± 0.4°C), and ultrasonic energy (0 ± 0.3°C) (all P<0.001). Stray energy couples to commonly used patient monitoring devices resulting in potentially significant thermal injury. The handheld bovie cord transfers energy via antenna coupling to neuromonitoring leads that can raise tissue temperatures over 100°F (39°C) using standard settings. The most effective ways to decrease this energy coupling is to reduce generator power, increase the separation between wires, or utilize lower voltage energy devices such as ultrasonic or bipolar energy.

  8. Outcomes of multiple wire localization for larger breast cancers: when can mastectomy be avoided?

    PubMed

    Kirstein, Laurie J; Rafferty, Elizabeth; Specht, Michelle C; Moore, Richard H; Taghian, Alphonse G; Hughes, Kevin S; Gadd, Michele A; Smith, Barbara L

    2008-09-01

    Mastectomy is often recommended when mammography shows a breast cancer with extensive calcifications. We wished to determine whether the use of multiple localizing wires to guide lumpectomy in this setting was associated with increased rates of breast conservation. We also wanted to identify factors that predicted a poor chance of successful lumpectomy, to avoid multiple lumpectomy attempts in a patient who would ultimately require mastectomy. Records of 153 women with breast cancer who underwent lumpectomy for larger lesions that required multiple wire localization and 196 controls who required only single wire localization were reviewed retrospectively. The number of localizing wires, specimen volume, largest specimen dimension, number of surgical procedures, and rates of breast conservation were scored. Seventy-seven percent of patients requiring multiple wire localization had successful breast conservation, compared with 90% of those needing only single wire localization. Only 28% of multiple wire patients required more than 1 excision to achieve clear margins, compared with 36% of single wire patients (p < 0.01). Breast conservation is possible in the great majority of breast cancer patients whose mammographic lesions require multiple localizing wires for excision. The use of multiple wires can decrease the number of procedures required to obtain clear lumpectomy margins.

  9. Air Force Science and Technology Plan

    DTIC Science & Technology

    2011-01-01

    charged particles and guide high- power microwaves and radiofrequency waves in the air • Bioenergy – developing renewable biosolar hydrogen...Aeronautical sciences, control sciences, structures and integration Directed Energy High- power microwaves , lasers, beam control, space situational...Propulsion Turbine and rocket engines, advanced propulsion systems , system -level thermal management, and propulsion fuels and propellants Sensors Air

  10. A new adjustable parallel drill guide for internal fixation of femoral neck fracture: a developmental and experimental study.

    PubMed

    Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin

    2016-01-11

    Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. The authors developed a new adjustable drill guide for cannulated screw guide wire insertion for multiple screw fixation. Eight orthopaedic surgeons performed the experimental study to evaluate the efficacy of this device. Each surgeon performed guide wire insertion for multiple screw fixation in six synthetic femurs: three times with the new device and three times with the conventional technique. The fluoroscopic time, operative time and surgeon satisfaction were evaluated. In the operations with the new adjustable drill guide, the fluoroscopic and operative times were significantly lower than the operations with the conventional technique (p < 0.05). The mean score for the level of satisfaction of this device was also statistically significantly better (p = 0.02) than the conventional technique. The fluoroscopic and operative times with the new adjustable drill guide were reduced for multiple screw fixation of femoral neck fracture and the satisfaction of the surgeons was good.

  11. US-guided percutaneous radiofrequency thermal ablation for the treatment of solid benign hyperfunctioning or compressive thyroid nodules.

    PubMed

    Deandrea, Maurilio; Limone, Paolo; Basso, Edoardo; Mormile, Alberto; Ragazzoni, Federico; Gamarra, Elena; Spiezia, Stefano; Faggiano, Antongiulio; Colao, Annamaria; Molinari, Filippo; Garberoglio, Roberto

    2008-05-01

    The aim of the study was to define the effectiveness and safety of ultrasound-guided percutaneous radiofrequency (RF) thermal ablation in the treatment of compressive solid benign thyroid nodules. Thirty-one patients not eligible for surgery or radioiodine (131I) treatment underwent RF ablation for benign nodules; a total of 33 nodules were treated (2 patients had 2 nodules treated in the same session): 10 cold nodules and 23 hyperfunctioning. Fourteen patients complained of compressive symptoms. Nodule volume, thyroid function and compressive symptoms were evaluated before treatment and at 1, 3 and 6 mo. Ultrasound-guided RF ablation was performed using a Starbust RITA needle, with nine expandable prongs; total exposure time was 6 to 10 min at 95 degrees C in one area or more of the nodule. Baseline volume (measured at the time of RF ablation) was 27.7 +/- 21.5 mL (mean +/- SD), but significantly decreased during follow-up: 19.2 +/- 16.2 at 1 mo (-32.7%; p < 0.001), 15.9 +/- 14.1 mL at 3 mo (-46.4 %; p < 0.001) and 14.6 +/- 12.6 mL at 6 mo (-50.7%; p < 0.001). After treatment, all patients with cold nodules remained euthyroid: five patients with hot nodules normalized thyroid function, and the remaining sixteen showed a partial remission of hyperthyroidism. Besides a sensation of heat and mild swelling of the neck, no major complications were observed. Improvement in compressive symptoms was reported by 13 patients, with a reduction on severity scale from 6.1 +/- 1.4 to 2.2 +/- 1.9 (p < 0.0001). Radiofrequency was effective and safe in reducing volume by about 50% and compressive symptoms in large benign nodules. Hyperfunction was fully controlled in 24% of patients and partially reduced in the others.

  12. Coronary and peripheral stenting in aorto-ostial protruding stents: The balloon assisted access to protruding stent technique.

    PubMed

    Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R

    2016-03-01

    Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.

  13. Micromachined actuators/sensors for intratubular positioning/steering

    DOEpatents

    Lee, A.P.; Krulevitch, P.A.; Northrup, M.A.; Trevino, J.C.

    1998-06-30

    Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems. 14 figs.

  14. A Potential Pitfall in the Use of the Monorail System for Carotid Stenting

    PubMed Central

    Pereira, E.; Birnbaum, L.

    2006-01-01

    Summary The use of EPDs seems to be necessary for safe CAS. Though the monorail system may offer advantages for a single operator, we caution its use with certain aortic arch anatomies. In such anatomies, using an OTW system or at least a 300 cm filter wire or devices that support wire extension will remedy some complications, such as the loss of the guiding sheath. As in our case, the added advantage of a 300 cm filter wire enabled us to avoid a poor outcome or an emergency vascular surgery. PMID:20569594

  15. A potential pitfall in the use of the monorail system for carotid stenting. A technical case report.

    PubMed

    Pereira, E; Birnbaum, L

    2006-12-15

    The use of EPDs seems to be necessary for safe CAS. Though the monorail system may offer advantages for a single operator, we caution its use with certain aortic arch anatomies. In such anatomies, using an OTW system or at least a 300 cm filter wire or devices that support wire extension will remedy some complications, such as the loss of the guiding sheath. As in our case, the added advantage of a 300 cm filter wire enabled us to avoid a poor outcome or an emergency vascular surgery.

  16. A comparison of line enhancement techniques: applications to guide-wire detection and respiratory motion tracking

    NASA Astrophysics Data System (ADS)

    Bismuth, Vincent; Vancamberg, Laurence; Gorges, Sébastien

    2009-02-01

    During interventional radiology procedures, guide-wires are usually inserted into the patients vascular tree for diagnosis or healing purpose. These procedures are monitored with an Xray interventional system providing images of the interventional devices navigating through the patient's body. The automatic detection of such tools by image processing means has gained maturity over the past years and enables applications ranging from image enhancement to multimodal image fusion. Sophisticated detection methods are emerging, which rely on a variety of device enhancement techniques. In this article we reviewed and classified these techniques into three families. We chose a state of the art approach in each of them and built a rigorous framework to compare their detection capability and their computational complexity. Through simulations and the intensive use of ROC curves we demonstrated that the Hessian based methods are the most robust to strong curvature of the devices and that the family of rotated filters technique is the most suited for detecting low CNR and low curvature devices. The steerable filter approach demonstrated less interesting detection capabilities and appears to be the most expensive one to compute. Finally we demonstrated the interest of automatic guide-wire detection on a clinical topic: the compensation of respiratory motion in multimodal image fusion.

  17. Fabrication of high-quality single-crystal Cu thin films using radio-frequency sputtering.

    PubMed

    Lee, Seunghun; Kim, Ji Young; Lee, Tae-Woo; Kim, Won-Kyung; Kim, Bum-Su; Park, Ji Hun; Bae, Jong-Seong; Cho, Yong Chan; Kim, Jungdae; Oh, Min-Wook; Hwang, Cheol Seong; Jeong, Se-Young

    2014-08-29

    Copper (Cu) thin films have been widely used as electrodes and interconnection wires in integrated electronic circuits, and more recently as substrates for the synthesis of graphene. However, the ultra-high vacuum processes required for high-quality Cu film fabrication, such as molecular beam epitaxy (MBE), restricts mass production with low cost. In this work, we demonstrated high-quality Cu thin films using a single-crystal Cu target and radio-frequency (RF) sputtering technique; the resulting film quality was comparable to that produced using MBE, even under unfavorable conditions for pure Cu film growth. The Cu thin film was epitaxially grown on an Al2O3 (sapphire) (0001) substrate, and had high crystalline orientation along the (111) direction. Despite the 10(-3) Pa vacuum conditions, the resulting thin film was oxygen free due to the high chemical stability of the sputtered specimen from a single-crystal target; moreover, the deposited film had >5× higher adhesion force than that produced using a polycrystalline target. This fabrication method enabled Cu films to be obtained using a simple, manufacturing-friendly process on a large-area substrate, making our findings relevant for industrial applications.

  18. Spectral Analysis of Ultrasound Radiofrequency Backscatter for the Detection of Intercostal Blood Vessels.

    PubMed

    Klingensmith, Jon D; Haggard, Asher; Fedewa, Russell J; Qiang, Beidi; Cummings, Kenneth; DeGrande, Sean; Vince, D Geoffrey; Elsharkawy, Hesham

    2018-04-19

    Spectral analysis of ultrasound radiofrequency backscatter has the potential to identify intercostal blood vessels during ultrasound-guided placement of paravertebral nerve blocks and intercostal nerve blocks. Autoregressive models were used for spectral estimation, and bandwidth, autoregressive order and region-of-interest size were evaluated. Eight spectral parameters were calculated and used to create random forests. An autoregressive order of 10, bandwidth of 6 dB and region-of-interest size of 1.0 mm resulted in the minimum out-of-bag error. An additional random forest, using these chosen values, was created from 70% of the data and evaluated independently from the remaining 30% of data. The random forest achieved a predictive accuracy of 92% and Youden's index of 0.85. These results suggest that spectral analysis of ultrasound radiofrequency backscatter has the potential to identify intercostal blood vessels. (jokling@siue.edu) © 2018 World Federation for Ultrasound in Medicine and Biology. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  19. Radiofrequency catheter ablation of atrial fibrillation: Electrical modification suggesting transmurality is faster achieved with remote magnetic catheter in comparison with contact force use.

    PubMed

    Bun, Sok-Sithikun; Ayari, Anis; Latcu, Decebal Gabriel; Errahmouni, Abdelkarim; Saoudi, Nadir

    2017-07-01

    Remote magnetic navigation (RMN) and contact force (CF) sensing catheters are available technologies for radiofrequency (RF) catheter ablation of atrial fibrillation (AF). Our purpose was to compare time to electrogram (EGM) modification suggesting transmural lesions between RMN and CF-guided AF ablation. A total of 1,008 RF applications were analyzed in 21 patients undergoing RMN (n = 11) or CF-guided ablation (n = 10) for paroxysmal AF. All procedures were performed in sinus rhythm during general anesthesia. Time to EGM modification was measured until transmurality criteria were fulfilled: (1) complete disappearance of R if initial QR morphology; (2) diminution > 75% of R if initial QRS morphology; (3) complete disappearance of R' of initial RSR' morphology. Impedance drop as well as force time integral (FTI) were also assessed for each application. Mean CF at the beginning of each RF application in the CF group was 11 ± 2 g and mean FTI per application was 488 ± 163 gs. Time to EGM modification was significantly shorter in the RMN group (4.52 ± 0.1 seconds vs. 5.6 ± 0.09 seconds; P < 0.00001). There was no significant difference between other procedural parameters. Remote magnetic AF ablation is associated with faster EGM modification suggesting transmurality than optimized CF and FTI-guided catheter ablation. © 2017 Wiley Periodicals, Inc.

  20. Small-bore wire-guided chest drains: safety, tolerability, and effectiveness in pneumothorax, malignant effusions, and pleural empyema.

    PubMed

    Cafarotti, Stefano; Dall'Armi, Valentina; Cusumano, Giacomo; Margaritora, Stefano; Meacci, Elisa; Lococo, F; Vita, M L; Porziella, V; Bonassi, S; Cesario, Alfredo; Granone, Pierluigi

    2011-03-01

    The use of small-bore wire-guided chest drains for pleural effusions and pneumothorax has become popular; however, limited data are available on its efficacy and morbidity. The aim of this retrospective study is to measure, via the analysis of the so far largest reported cohort, the efficacy, safety, and tolerability of this approach in different clinical conditions. In the period from January 2002 to December 2008, 1092 patients have undergone the positioning of a small-bore wire-guided chest drain (12F) for the evidence of pneumothorax or pleural effusion and have been monitored over time for morbidity, pain at the time of insertion (measured via the visual analogue scale), and drain failure for misplacement or blockage. Patients with trauma were excluded from this study. Male/female ratio and mean age were respectively 418:674 and 55.85 ± 18.6. Three-hundred ninety-nine (36.5%) drains were inserted for pneumothorax, 324 (29.7%) for malignant effusion, 97 (8.9%) for empyema, and 272 (24.9%) for nonmalignant effusion. The pain experience was on average "very mild" (mean visual analogue scale = 4.6 mm). The overall drain failure rate was 12.9%. The percentage of successful cases was 93.8% in malignant effusion, 93% in pneumothorax, and 92.3% in nonmalignant effusion; in the cases of pathologically diagnosed empyema, drains were more likely to get blocked (74.2%). We recorded 1 serious complication within the malignant effusion group. Wire-guided 12F Seldinger-type drains are a well-tolerated and effective method of treating pneumothorax and uncomplicated pleural effusions (malignant and nonmalignant) with acceptable morbidity. The use of 12F small-bore chest drain is not indicated for the treatment of empyema. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  1. Navigation with Electromagnetic Tracking for Interventional Radiology Procedures

    PubMed Central

    Wood, Bradford J.; Zhang, Hui; Durrani, Amir; Glossop, Neil; Ranjan, Sohan; Lindisch, David; Levy, Eliott; Banovac, Filip; Borgert, Joern; Krueger, Sascha; Kruecker, Jochen; Viswanathan, Anand; Cleary, Kevin

    2008-01-01

    PURPOSE To assess the feasibility of the use of preprocedural imaging for guide wire, catheter, and needle navigation with electromagnetic tracking in phantom and animal models. MATERIALS AND METHODS An image-guided intervention software system was developed based on open-source software components. Catheters, needles, and guide wires were constructed with small position and orientation sensors in the tips. A tetrahedral-shaped weak electromagnetic field generator was placed in proximity to an abdominal vascular phantom or three pigs on the angiography table. Preprocedural computed tomographic (CT) images of the phantom or pig were loaded into custom-developed tracking, registration, navigation, and rendering software. Devices were manipulated within the phantom or pig with guidance from the previously acquired CT scan and simultaneous real-time angiography. Navigation within positron emission tomography (PET) and magnetic resonance (MR) volumetric datasets was also performed. External and endovascular fiducials were used for registration in the phantom, and registration error and tracking error were estimated. RESULTS The CT scan position of the devices within phantoms and pigs was accurately determined during angiography and biopsy procedures, with manageable error for some applications. Preprocedural CT depicted the anatomy in the region of the devices with real-time position updating and minimal registration error and tracking error (<5 mm). PET can also be used with this system to guide percutaneous biopsies to the most metabolically active region of a tumor. CONCLUSIONS Previously acquired CT, MR, or PET data can be accurately codisplayed during procedures with reconstructed imaging based on the position and orientation of catheters, guide wires, or needles. Multimodality interventions are feasible by allowing the real-time updated display of previously acquired functional or morphologic imaging during angiography, biopsy, and ablation. PMID:15802449

  2. Evaluating Thermally Damaged Polyimide Insulated Wiring (MIL-W-81381) with Ultrasound

    NASA Technical Reports Server (NTRS)

    Madaras, Eric I.; Anastasi, Robert F.

    2002-01-01

    A series of experiments to investigate the use of ultrasound for measuring wire insulation have been conducted. Initial laboratory tests were performed on MIL-W-81381/7,/12, and /21 aviation wire, a wire that has polyimide (Kapton Registered Trademark) layers for insulation. Samples of this wiring were exposed to 370C temperatures for different periods of time to induce a range of thermal damage. For each exposure, 12 samples of each gauge (12, 16, and 20 gauges) were processed. The velocity of the lowest order axisymmetric ultrasonic guided mode, a mode that is sensitive to the geometry and stiffness of the wire conductor and insulation, was measured. The phase velocity for the 20-gauge MIL-W-81381/7 wire had a baseline value of 3023 +/- 78 m/s. After exposure to the high temperatures, the wire's phase velocity rapidly increased, and reached an asymptotic value of 3598 +/- 20 m/s after 100 hours exposure. Similar behavior was measured for the 16 gauge MIL-W-81381/21 wire and 12 gauge MIL-W-81381/12 wire which had baseline values of 3225 +/- 22 m/s and 3403 +/- 33 m/s respectively, and reached asymptotic values of 3668 +/- 19 m/s, and 3679 +/- 42 m/s respectively. These measured velocity changes represent changes of 19, 14, and 8 percent respectively for the 20, 16, and 12 gauge wires. Finally, some results for a wire with an ethylene tetrafluoroethylene insulation are reported. Qualitatively similar behaviors are noted ultrasonically.

  3. The BridgePoint devices to facilitate recanalization of chronic total coronary occlusions through controlled subintimal reentry.

    PubMed

    Werner, Gerald S

    2011-01-01

    In view of the improved long-term patency with drug-eluting stents, the challenge with chronic total coronary occlusion remains a low primary success rate. Modes of failure to open a chronic total coronary occlusion are mainly related to the inability to pass a wire through the proximal occlusion cap, and the most difficult part of the procedure is to guide the wire into the distal true lumen. A frequent situation is a subintimal wire position. The BridgePoint (BridgePoint Medical, MN, USA) family of devices is designed to cope with both of these problems. First, the CrossBoss™ catheter aims at passing through the proximal cap by manual rotation of a blunt proximal tip, and second, in case of a subintimal position, the Stingray™ balloon enables guided reentry from the subintimal space into the true lumen. Certain features of an occlusion might favor the CrossBoss device, while the reentry approach may also be used as a standalone bailout method. The aim is to provide a means to resolve otherwise failed attempts and to make it unnecessary to resort to the more complex and time-consuming retrograde wire techniques through collateral channels with the associated potential higher procedural risks.

  4. Successful treatment of tumor-induced osteomalacia with CT-guided percutaneous ethanol and cryoablation.

    PubMed

    Tutton, Sean; Olson, Erik; King, David; Shaker, Joseph L

    2012-10-01

    Tumor-induced osteomalacia is a rare condition usually caused by benign mesenchymal tumors. When the tumor can be found, patients are usually managed by wide excision of the tumor. We report a 51-yr-old male with clinical and biochemical evidence of tumor-induced osteomalacia caused by a mesenchymal tumor in the right iliac bone. He declined surgery and appears to have been successfully managed by computed tomography-guided percutaneous ethanol ablation and percutaneous cryoablation. Our patient appears to have had an excellent clinical and biochemical response to computed tomography-guided percutaneous ethanol ablation and percutaneous cryoablation. We found one prior case of image-guided ablation using radiofrequency ablation for tumor-induced osteomalacia. Although the standard treatment for tumor-induced osteomalacia is wide excision of the tumor, image-guided ablation may be an option in patients who cannot have appropriate surgery or who decline surgery.

  5. A New Radiofrequency Ablation Procedure to Treat Sacroiliac Joint Pain.

    PubMed

    Cheng, Jianguo; Chen, See Loong; Zimmerman, Nicole; Dalton, Jarrod E; LaSalle, Garret; Rosenquist, Richard

    2016-01-01

    Low back pain may arise from disorders of the sacroiliac joint in up to 30% of patients. Radiofrequency ablation (RFA) of the nerves innervating the sacroiliac joint has been shown to be a safe and efficacious strategy. We aimed to develop a new RFA technique to relieve low back pain secondary to sacroiliac joint disorders. Methodology development with validation through prospective observational non-randomized trial (PONRT). Academic multidisciplinary health care system, Ohio, USA. We devised a guide-block to facilitate accurate placement of multiple electrodes to simultaneously ablate the L5 dorsal ramus and lateral branches of the S1, S2, and S3 dorsal rami. This was achieved by bipolar radiofrequency ablation (b-RFA) to create a strip lesion from the lateral border of the base of the sacral superior articular process (L5-S1 facet joint) to the lateral border of the S3 sacral foramen. We applied this technique in 31 consecutive patients and compared the operating time, x-ray exposure time and dose, and clinical outcomes with patients (n = 62) who have been treated with the cooled radiofrequency technique. Patients' level of pain relief was reported as < 50%, 50 - 80%, and > 80% pain relief at one, 3, 6, and 12 months after the procedure. The relationship between RFA technique and duration of pain relief was evaluated using interval-censored multivariable Cox regression. The new technique allowed reduction of operating time by more than 50%, x-ray exposure time and dose by more than 80%, and cost by more than $1,000 per case. The percent of patients who achieved > 50% pain reduction was significantly higher in the b-RFA group at 3, 6, and 12 months follow-up, compared to the cooled radiofrequency group. No complications were observed in either group. Although the major confounding factors were taken into account in the analysis, use of historical controls does not balance observed and unobserved potential confounding variables between groups so that the reported results are potentially confounded. Compared to the cooled radiofrequency ablation (c-RFA) technique, the new b-RFA technique reduced operating time by more than 50%, decreased x-ray exposure by more than 80%, and cut the cost by more than $1000 per case. The new method was associated with significantly improved clinical outcomes despite the limitations of the study design. Thus this new technique appeared to be safe, efficacious, and cost-effective. Key words: Sacroiliac joint pain, sacroiliac joint, low back pain, radiofrequency ablation (RFA), bipolar radiofrequency ablation (b-RFA), cooled radiofrequency ablation (c-RFA), cost-effectiveness.

  6. Percutaneous Radiofrequency Ablation for Treatment of Recurrent Retroperitoneal Liposarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keil, Sebastian, E-mail: keil@rad.rwth-aachen.de; Bruners, Philipp; Brehmer, Bernhard

    2008-07-15

    Percutaneous CT-guided radiofrequency ablation (RFA) is becoming more and more established in the treatment of various neoplasms, including retroperitoneal tumors of the kidneys and the adrenal glands. We report the case of RFA in a patient suffering from the third relapse of a retroperitoneal liposarcoma in the left psoas muscle. After repeated surgical resection and supportive radiation therapy of a primary retroperitoneal liposarcoma and two surgically treated recurrences, including replacement of the ureter by a fraction of the ileum, there was no option for further surgery. Thus, we considered RFA as the most suitable treatment option. Monopolar RFA was performedmore » in a single session with a 2-cm umbrella-shaped LeVeen probe. During a 27-month follow-up period the patient remained free of tumor.« less

  7. Stiffness and frictional resistance of a superelastic nickel-titanium orthodontic wire with low-stress hysteresis.

    PubMed

    Liaw, Yu-Cheng; Su, Yu-Yu M; Lai, Yu-Lin; Lee, Shyh-Yuan

    2007-05-01

    Stress-induced martensite formation with stress hysteresis that changes the elasticity and stiffness of nickel-titanium (Ni-Ti) wire influences the sliding mechanics of archwire-guided tooth movement. This in-vitro study investigated the frictional behavior of an improved superelastic Ni-Ti wire with low-stress hysteresis. Improved superelastic Ni-Ti alloy wires (L & H Titan, Tomy International, Tokyo, Japan) with low-stress hysteresis were examined by using 3-point bending and frictional resistance tests with a universal test machine at a constant temperature of 35 degrees C, and compared with the former conventional austenitic-active superelastic Ni-Ti wires (Sentalloy, Tomy International). Wire stiffness levels were derived from differentiation of the polynomial regression of the unloading curves, and values for kinetic friction were measured at constant bending deflection distances of 0, 2, 3, and 4 mm, respectively. Compared with conventional Sentalloy wires, the L & H Titan wire had a narrower stress hysteresis including a lower loading plateau and a higher unloading plateau. In addition, L & H Titan wires were less stiff than the Sentalloy wires during most unloading stages. Values of friction measured at deflections of 0, 2, and 3 mm were significantly (P <.05) increased in both types of wire. However, they showed a significant decrease in friction from 3 to 4 mm of deflection. L & H Titan wires had less friction than Sentalloy wires at all bending deflections (P <.05). Stress-induced martensite formation significantly reduced the stiffness and thus could be beneficial to decrease the binding friction of superelastic Ni-Ti wires during sliding with large bending deflections. Austenitic-active alloy wires with low-stress hysteresis and lower stiffness and friction offer significant potential for further investigation.

  8. Guided Growth of Horizontal ZnSe Nanowires and their Integration into High-Performance Blue-UV Photodetectors.

    PubMed

    Oksenberg, Eitan; Popovitz-Biro, Ronit; Rechav, Katya; Joselevich, Ernesto

    2015-07-15

    Perfectly aligned horizontal ZnSe nano-wires are obtained by guided growth, and easily integrated into high-performance blue-UV photodetectors. Their crystal phase and crystallographic orientation are controlled by the epitaxial relations with six different sapphire planes. Guided growth paves the way for the large-scale integration of nanowires into optoelectronic devices. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Whole shaft visibility and mechanical performance for active MR catheters using copper-nitinol braided polymer tubes.

    PubMed

    Kocaturk, Ozgur; Saikus, Christina E; Guttman, Michael A; Faranesh, Anthony Z; Ratnayaka, Kanishka; Ozturk, Cengizhan; McVeigh, Elliot R; Lederman, Robert J

    2009-08-12

    Catheter visualization and tracking remains a challenge in interventional MR.Active guidewires can be made conspicuous in "profile" along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new "active" catheter design for interventional MR with mechanical performance resembling braided X-ray devices. Our 75 cm long hybrid catheter shaft incorporates a wire lattice in a polymer matrix, and contains three distal loop coils in a flexible and torquable 7Fr device. We explored the impact of braid material designs on radiofrequency and mechanical performance. The incorporation of copper wire into in a superelastic nitinol braided loopless antenna allowed good visualization of the whole shaft (70 cm) in vitro and in vivo in swine during real-time MR with 1.5 T scanner. Additional distal tip coils enhanced tip visibility. Increasing the copper:nitinol ratio in braiding configurations improved flexibility at the expense of torquability. We found a 16-wire braid of 1:1 copper:nitinol to have the optimum balance of mechanical (trackability, flexibility, torquability) and antenna (signal attenuation) properties. With this configuration, the temperature increase remained less than 2 degrees C during real-time MR within 10 cm horizontal from the isocenter. The design was conspicuous in vitro and in vivo. We have engineered a new loopless antenna configuration that imparts interventional MR catheters with satisfactory mechanical and imaging characteristics. This compact loopless antenna design can be generalized to visualize the whole shaft of any general-purpose polymer catheter to perform safe interventional procedures.

  10. Whole shaft visibility and mechanical performance for active MR catheters using copper-nitinol braided polymer tubes

    PubMed Central

    Kocaturk, Ozgur; Saikus, Christina E; Guttman, Michael A; Faranesh, Anthony Z; Ratnayaka, Kanishka; Ozturk, Cengizhan; McVeigh, Elliot R; Lederman, Robert J

    2009-01-01

    Background Catheter visualization and tracking remains a challenge in interventional MR. Active guidewires can be made conspicuous in "profile" along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new "active" catheter design for interventional MR with mechanical performance resembling braided X-ray devices. Our 75 cm long hybrid catheter shaft incorporates a wire lattice in a polymer matrix, and contains three distal loop coils in a flexible and torquable 7Fr device. We explored the impact of braid material designs on radiofrequency and mechanical performance. Results The incorporation of copper wire into in a superelastic nitinol braided loopless antenna allowed good visualization of the whole shaft (70 cm) in vitro and in vivo in swine during real-time MR with 1.5 T scanner. Additional distal tip coils enhanced tip visibility. Increasing the copper:nitinol ratio in braiding configurations improved flexibility at the expense of torquability. We found a 16-wire braid of 1:1 copper:nitinol to have the optimum balance of mechanical (trackability, flexibility, torquability) and antenna (signal attenuation) properties. With this configuration, the temperature increase remained less than 2°C during real-time MR within 10 cm horizontal from the isocenter. The design was conspicuous in vitro and in vivo. Conclusion We have engineered a new loopless antenna configuration that imparts interventional MR catheters with satisfactory mechanical and imaging characteristics. This compact loopless antenna design can be generalized to visualize the whole shaft of any general-purpose polymer catheter to perform safe interventional procedures. PMID:19674464

  11. Percutaneous Biopsy and Radiofrequency Ablation of Osteoid Osteoma with Excess Reactive New Bone Formation and Cortical Thickening Using a Battery-Powered Drill for Access: A Technical Note

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Filippiadis, D., E-mail: dfilippiadis@yahoo.gr; Gkizas, C., E-mail: chgkizas@gmail.com; Kostantos, C., E-mail: drkarpen@yahoo.gr

    PurposeTo report our experience with the use of a battery-powered drill in biopsy and radiofrequency ablation of osteoid osteoma with excess reactive new bone formation. The battery-powered drill enables obtaining the sample while drilling.Materials and MethodsDuring the last 18 months, 14 patients suffering from painful osteoid osteoma with excess reactive new bone formation underwent CT-guided biopsy and radiofrequency ablation. In order to assess and sample the nidus of the osteoid osteoma, a battery-powered drill was used. Biopsy was performed in all cases. Then, coaxially, a radiofrequency electrode was inserted and ablation was performed with osteoid osteoma protocol. Procedure time (i.e., drillingmore » including local anesthesia), amount of scans, technical and clinical success, and the results of biopsy are reported.ResultsAccess to the nidus through the excess reactive new bone formation was feasible in all cases. Median procedure time was 50.5 min. Histologic verification of osteoid osteoma was performed in all cases. Radiofrequency electrode was coaxially inserted within the nidus and ablation was successfully performed in all lesions. Median amount CT scans, performed to control correct positioning of the drill and precise electrode placement within the nidus was 11. There were no complications or material failure reported in our study.ConclusionsThe use of battery-powered drill facilitates access to the osteoid osteoma nidus in cases where excess reactive new bone formation is present. Biopsy needle can be used for channel creation during the access offering at the same time the possibility to extract bone samples.« less

  12. Sacroiliac joint pain: Prospective, randomised, experimental and comparative study of thermal radiofrequency with sacroiliac joint block.

    PubMed

    Cánovas Martínez, L; Orduña Valls, J; Paramés Mosquera, E; Lamelas Rodríguez, L; Rojas Gil, S; Domínguez García, M

    2016-05-01

    To compare the analgesic effects between the blockade and bipolar thermal radiofrequency in the treatment of sacroiliac joint pain. Prospective, randomised and experimental study conducted on 60 patients selected in the two hospitals over a period of nine months, who had intense sacroiliac joint pain (Visual Analogue Scale [VAS]>6) that lasted more than 3 months. Patients were randomised into three groups (n=20): Group A (two intra-articular sacroiliac injections of local anaesthetic/corticosteroid guided by ultrasound in 7 days). Group B: conventional bipolar radiofrequency "palisade". Target points were the lateral branch nerves of S1, S2, and S3, distance needles 1cm. Group C: modified bipolar radiofrequency "palisade" (needle distance >1cm). Patients were evaluated at one month, three months, and one year. Demographic data, VAS reduction, and side effects of the techniques were assessed. One month after the treatment, pain reduction was >50% in the three groups P<.001. Three and 12 months after the technique, the patients of the group A did not have a significant reduction in pain. At 3 months, almost 50% patients of the group B referred to improvement of the pain (P=.03), and <25% at 12 months, and those results were statistically significant (P=.01) compared to the baseline. Group C showed an improvement of 50% at 3 and 12 months (P<.001). All patients completed the study. Bipolar radiofrequency "palisade", especially when the distance between the needles was increased, was more effective and lasted longer, compared to join block and steroids, in relieving pain sacroiliac joint. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Percutaneous Treatment of Coronary Chronic Total Occlusion Part 2: Technical Approach

    PubMed Central

    Galassi, Alfredo; Grantham, Aaron; Kandzari, David; Lombardi, William; Moussa, Issam; Thompson, Craig; Werner, Gerald; Chambers, Charles

    2014-01-01

    Dual injection is recommended for nearly all chronic total occlusion (CTO) percutaneous coronary intervention (PCI) to determine the optimal crossing strategy and guide wire advancement into the distal true lumen. Strategies that provide enhanced guide catheter support (such as long sheaths, large-bore guiding catheters, use of guide catheter extensions, and anchor techniques) are important for maximising the success rate and efficiency of CTO PCI. Use of a microcatheter or over-the-wire balloon is strongly recommended in CTO PCI for enhancing the penetrating power of the guidewire, enabling change in tip shape and allowing guidewire change (stiff CTO guidewires are not optimal for crossing non-occluded coronary segments). Adherence to a procedural strategy that standardises CTO technique and facilitates procedural success is recommended. Such a strategy would permit stepwise decision-making for antegrade and retrograde methods; inform guidewire selection; and incorporate alternative approaches for instances of initial failure. Given the paucity of long-term outcomes with use of novel crossing techniques (antegrade dissection/re-entry and retrograde), antegrade wire escalation is the preferred CTO crossing technique, if technically feasible. Using measures to minimise radiation exposure (including but not limited to use of 7.5 frames per second fluoroscopy and use of low magnification) and contrast administration is recommended. CTO PCI is best performed at centres with dedicated CTO PCI experience and expertise. Use of crossing difficulty prediction tools, such as the J-CTO score, can facilitate the selection of cases with a high likelihood of quick crossing that can be attempted at less experienced centres. PMID:29588803

  14. Intrasystem Analysis Program (IAP) Structural Design Study.

    DTIC Science & Technology

    1981-06-01

    accuracy constraints, and user competence . This report is designed to serve as a guide in con- structing procedures and identifying those aspects of the...parameters. 3.3.3 Userability The term "Userability" refers here to the level of competence assumed for an IAP analyst in need of a procedure. There...media the wires pass through is homogeneous along the length of the wires. Under these assumptions the wave propagation is predominantly tranverse

  15. Defense Science Board Summer Study on Autonomy

    DTIC Science & Technology

    2016-06-01

    hours, at a maximum velocity of 40 mph, with a maximum payload of 9 kg (20 lbs); a maximum range of 160 km (100 miles); and can operate in wind /gust...existing mine disposal platform, such as Seafox, with contact reacquisition and neutralization capability. Seafox is a wire -guided mine neutralizer...functions, will retain operator control of neutralization and will remove the need for personnel to enter the minefield to execute fly- by- wire

  16. Anatomic Assessment of K-Wire Trajectory for Transverse Percutaneous Fixation of Small Finger Metacarpal Fractures: A Cadaveric Study.

    PubMed

    Grandizio, Louis C; Speeckaert, Amy; Kozick, Zach; Klena, Joel C

    2018-01-01

    The purpose of this cadaveric study is to evaluate the trajectory of percutaneous transverse Kirschner wire (K-wire) placement for fifth metacarpal fractures relative to the sagittal profile of the fifth metacarpal in order to develop a targeting strategy for the treatment of fifth metacarpal fractures. Using 12 unmatched fresh human upper limbs, we evaluated the trajectory of percutaneous transverse K-wire placement relative to the sagittal profile of the fifth metacarpal in order to develop a targeting strategy for treatment of fifth metacarpal fractures. The midpoint of the small and ring finger metacarpals in the sagittal plane was identified at 3 points. At each point, a K-wire was inserted from the small finger metacarpal into the midpoint of the ring finger metacarpal ("center-center" position). The angle of the transverse K-wire relative to the table needed to achieve a center-center position averaged 20.8°, 18.9°, and 16.7° for the proximal diaphysis, middiaphysis, and the collateral recess, respectively. Approximately 80% of transversely placed K-wires obtained purchase in the long finger metacarpal. These results can serve as a guide to help surgeons in the accurate placement of percutaneous K-wires for small finger metacarpal fractures and may aid in surgeon training.

  17. Survival after Radiofrequency Ablation in 122 Patients with Inoperable Colorectal Lung Metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gillams, Alice, E-mail: alliesorting@gmail.com; Khan, Zahid; Osborn, Peter

    2013-06-15

    Purpose. To analyze the factors associated with favorable survival in patients with inoperable colorectal lung metastases treated with percutaneous image-guided radiofrequency ablation. Methods. Between 2002 and 2011, a total of 398 metastases were ablated in 122 patients (87 male, median age 68 years, range 29-90 years) at 256 procedures. Percutaneous CT-guided cool-tip radiofrequency ablation was performed under sedation/general anesthesia. Maximum tumor size, number of tumors ablated, number of procedures, concurrent/prior liver ablation, previous liver or lung resection, systemic chemotherapy, disease-free interval from primary resection to lung metastasis, and survival from first ablation were recorded prospectively. Kaplan-Meier analysis was performed, andmore » factors were compared by log rank test. Results. The initial number of metastases ablated was 2.3 (range 1-8); the total number was 3.3 (range 1-15). The maximum tumor diameter was 1.7 (range 0.5-4) cm, and the number of procedures was 2 (range 1-10). The major complication rate was 3.9 %. Overall median and 3-year survival rate were 41 months and 57 %. Survival was better in patients with smaller tumors-a median of 51 months, with 3-year survival of 64 % for tumors 2 cm or smaller versus 31 months and 44 % for tumors 2.1-4 cm (p = 0.08). The number of metastases ablated and whether the tumors were unilateral or bilateral did not affect survival. The presence of treated liver metastases, systemic chemotherapy, or prior lung resection did not affect survival. Conclusion. Three-year survival of 57 % in patients with inoperable colorectal lung metastases is better than would be expected with chemotherapy alone. Patients with inoperable but small-volume colorectal lung metastases should be referred for ablation.« less

  18. Radiofrequency ablation of neuroendocrine liver metastases: the Middlesex experience.

    PubMed

    Gillams, A; Cassoni, A; Conway, G; Lees, W

    2005-01-01

    Current treatment options for neuroendocrine liver metastases are not widely applicable or not that effective. Image-guided thermal ablation offers the possibility of a minimally invasive, albeit palliative, treatment that decreases tumor volume, preserves most of the normal liver, and can be repeated several times. We report our experience with image-guided thermal ablation in 25 patients with unresectable liver metastases. Since 1990 we have treated 189 tumors at 66 treatment sessions in 25 patients (12 female, 13 male; median age, 56 years; age range, 26--78 years). Thirty treatments were performed with a solid-state laser, and 36 treatments were performed with radiofrequency ablation. All but one treatment was performed percutaneously under image guidance. Sixteen patients had metastases from carcinoid primaries, three from gastrinoma, two from insulinoma, and four from miscellaneous causes. Fourteen of 25 had symptoms from hormone secretion. Imaging follow-up was available in 19 patients at a median of 21 months (range, 4--75 months). There was a complete response in six patients, a partial response in seven, and stable disease in one; hence, tumor load was controlled in 14 of 19 patients (74%). Relief of hormone-related symptoms was achieved in nine of 14 patients (69%). The median survival period from the diagnosis of liver metastases was 53 months. One patient with end-stage cardiac disease died after a carcinoid crisis. There were eight (12%) complications: five local and three distant, four major and four minor. As a minimally invasive, readily repeatable procedure that can be used to ablate small tumors, preferably before patients become severely symptomatic, radiofrequency ablation can provide effective control of liver tumor volume in most patients over many years.

  19. NASA Hybrid Reflectometer Project

    NASA Technical Reports Server (NTRS)

    Lynch, Dana; Mancini, Ron (Technical Monitor)

    2002-01-01

    Time-domain and frequency-domain reflectometry have been used for about forty years to locate opens and shorts in cables. Interpretation of reflectometry data is as much art as science. Is there information in the data that is being missed? Can the reflectometers be improved to allow us to detect and locate defects in cables that are not outright shorts or opens? The Hybrid Reflectometer Project was begun this year at NASA Ames Research Center, initially to model wire physics, simulating time-domain reflectometry (TDR) signals in those models and validating the models against actual TDR data taken on testbed cables. Theoretical models of reflectometry in wires will give us an understanding of the merits and limits of these techniques and will guide the application of a proposed hybrid reflectometer with the aim of enhancing reflectometer sensitivity to the point that wire defects can be detected. We will point out efforts by some other researchers to apply wire physics models to the problem of defect detection in wires and we will describe our own initial efforts to create wire physics models and report on testbed validation of the TDR simulations.

  20. Terahertz generation from laser-driven ultrafast current propagation along a wire target

    NASA Astrophysics Data System (ADS)

    Zhuo, H. B.; Zhang, S. J.; Li, X. H.; Zhou, H. Y.; Li, X. Z.; Zou, D. B.; Yu, M. Y.; Wu, H. C.; Sheng, Z. M.; Zhou, C. T.

    2017-01-01

    Generation of intense coherent THz radiation by obliquely incidenting an intense laser pulse on a wire target is studied using particle-in-cell simulation. The laser-accelerated fast electrons are confined and guided along the surface of the wire, which then acts like a current-carrying line antenna and under appropriate conditions can emit electromagnetic radiation in the THz regime. For a driving laser intensity ˜3 ×1018W /cm2 and pulse duration ˜10 fs, a transient current above 10 KA is produced on the wire surface. The emission-cone angle of the resulting ˜0.15 mJ (˜58 GV/m peak electric field) THz radiation is ˜30∘ . The conversion efficiency of laser-to-THz energy is ˜0.75 % . A simple analytical model that well reproduces the simulated result is presented.

  1. Measurement and Modeling of Dispersive Pulse Propagation in Drawn Wire Waveguides

    NASA Technical Reports Server (NTRS)

    Madaras, Eric I.; Kohl, Thomas W.; Rogers, Wayne P.

    1995-01-01

    An analytical model of dispersive pulse propagation in semi-infinite cylinders due to transient axially symmetric end conditions has been experimentally investigated. Specifically, the dispersive propagation of the first axially symmetric longitudinal mode in thin wire waveguides, which have ends in butt contact with longitudinal piezoelectric ultrasonic transducers, is examined. The method allows for prediction of a propagated waveform given a measured source waveform, together with the material properties of the cylinder. Alternatively, the source waveform can be extracted from measurement of the propagated waveform. The material properties required for implementation of the pulse propagation model are determined using guided wave phase velocity measurements. Hard tempered aluminum 1100 and 304 stainless steel wires, with 127, 305, and 406 micron diam., were examined. In general, the drawn wires were found to behave as transversely isotropic media.

  2. Measurement and modeling of dispersive pulse propagation in draw wire waveguides

    NASA Technical Reports Server (NTRS)

    Madaras, Eric I.; Kohl, Thomas W.; Rogers, Wayne P.

    1995-01-01

    An analytical model of dispersive pulse propagation in semi-infinite cylinders due to transient axially symmetric end conditions has been experimentally investigated. Specifically, the dispersive propagation of the first axially symmetric longitudinal mode in thin wire waveguides, which have ends in butt contact with longitudinal piezoelectric ultrasonic transducers, is examined. The method allows for prediction of a propagated waveform given a measured source waveform, together with the material properties of the cylinder. Alternatively, the source waveform can be extracted from measurement of the propagated waveform. The material properties required for implementation of the pulse propagation model are determined using guided wave phase velocity measurements. Hard tempered aluminum 1100 and 304 stainless steel wires, with 127, 305, and 406 micron diam., were examined. In general, the drawn wires were found to behave as transversely isotropic media.

  3. Long-term results of CT-guided percutaneous radiofrequency ablation of inoperable patients with stage Ia non-small cell lung cancer: A retrospective cohort study.

    PubMed

    Huang, Bing-Yang; Li, Xin-Min; Song, Xiao-Yong; Zhou, Jun-Jun; Shao, Zhuang; Yu, Zhi-Qi; Lin, Yi; Guo, Xin-Yu; Liu, Da-Jiang; Li, Lu

    2018-05-01

    This study was performed to retrospectively evaluate the 10-year overall survival (OS), progression-free survival (PFS), and local control rates of patients with inoperable stage Ia non-small cell lung cancer (NSCLC) who underwent computed tomography (CT)-guided radiofrequency ablation (RFA) in a single center. Fifty patients with inoperable NSCLC underwent RFA between 2004 and 2016. Thoracic surgeons evaluated the patients and performed RFA under CT guidance. Follow-up CT and positron emission tomography/CT scans were obtained. Local control rates and recurrence patterns were analyzed. Seventy-three lesions in 50 patients (M:F = 22:28; median age: 73 years; range: 52-82 years) were treated with CT-guided RFA. The mean lesion size was 2.2 cm (range: 1-3 cm). No procedure-related deaths occurred. Low-grade fever was the most common post-ablation complication, with an incidence rate of 36%. The 1-, 2-, 3-, 5-, and 10-year OS rates of patients with Ia NSCLC were 96.0%, 86.5%, 67.1%, 36.3%, and 1%, respectively, and the 1-, 2-, 3-, and 5-year PFS rates were 94.0%, 77.5%, 43.5%, and 10.8%, respectively. The most common pattern of recurrence was local, and 15 patients with recurrence were treated with repeat RFA. Tumor size <2.0 cm was associated with a significantly improved 3-year survival rate of 78.9%. CT-guided RFA is feasible and well tolerated by inoperable patients with inoperable stage Ia NSCLC. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  4. High Voltage Guided Pulmonary Vein Isolation in Paroxysmal Atrial Fibrillation.

    PubMed

    Boles, Usama; Gul, Enes E; Enriquez, Andres; Lee, Howard; Riegert, Dave; Andres, Adrian; Baranchuk, Adrian; Redfearn, Damian; Glover, Benedict; Simpson, Chris; Abdollah, Hoshiar; Michael, Kevin

    2017-01-01

    Ablation of the pulmonary vein (PV) antrum using an electroanatomic mapping system is standard of care for point-by-point pulmonary vein isolation (PVI). Focused ablation at critical areas is more likely to achieve intra-procedural PV isolation and decrease the likelihood for reconnection and recurrence of atrial fibrillation (AF). Therefore this prospective pilot study is to investigate the short-term outcome of a voltage-guided circumferential PV ablation (CPVA) strategy. We recruited patients with a history of paroxysmal atrial fibrillation (AF). The EnSite NavX system (St. Jude Medical, St Paul, Minnesota, USA) was employed to construct a three-dimensional geometry of the left atrium (LA) and voltage map. CPVA was performed; with radiofrequency (RF) targeting sites of highest voltage first in a sequential clockwise fashion then followed by complete the gaps in circumferential ablation. Acute and short-term outcomes were compared to a control group undergoing conventional standard CPVA using the same 3D system. Follow-up was scheduled at 3, 6 and 12 months. Thirty-four paroxysmal AF patients with a mean age of 40 years were included. Fourteen patients (8 male) underwent voltage mapping and 20 patients underwent empirical, non-voltage guided standard CPVA. A mean of 54 ± 12 points per PV antrum were recorded. Mean voltage for right and left PVs antra were 1.7±0.1 mV and 1.9±0.2 mV, respectively. There was a trend towards reduced radiofrequency time (40.9±17.4 vs. 48.1±15.5 mins; p=0.22). Voltage-guided CPVA is a promising strategy in targeting critical points for PV isolation with a lower trend of AF recurrence compared with a standard CPVA in short-term period. Extended studies to confirm these findings are warranted.

  5. Intracardiac echo-guided radiofrequency catheter ablation of atrial fibrillation in patients with atrial septal defect or patent foramen ovale repair: a feasibility, safety, and efficacy study.

    PubMed

    Lakkireddy, Dhanunjaya; Rangisetty, Umamahesh; Prasad, Subramanya; Verma, Atul; Biria, Mazda; Berenbom, Loren; Pimentel, Rhea; Emert, Martin; Rosamond, Thomas; Fahmy, Tamer; Patel, Dimpi; Di Biase, Luigi; Schweikert, Robert; Burkhardt, David; Natale, Andrea

    2008-11-01

    Intracardiac Echo-Guided Radiofrequency Catheter. Patients with atrial septal defect (ASD) are at higher risk for atrial fibrillation (AF) even after repair. Transseptal access in these patients is perceived to be difficult. We describe the feasibility, safety, and efficacy of pulmonary vein antral isolation (PVAI) in these patients. We prospectively compared post-ASD/patent foramen ovale (PFO) repair patients (group I, n = 45) with age-gender-AF type matched controls (group II, n = 45). All the patients underwent PVAI through a double transseptal puncture with a roving circular mapping catheter technique guided by intracardiac echocardiography (ICE). The short-term (3 months) and long-term (12 month) failure rates were assessed. In group I, 23 (51%) had percutaneous closure devices and 22 (49%) had a surgical closure. There was no significant difference between group I and II in the baseline characteristics. Intracardiac echo-guided double transseptal access was obtained in 98% of patients in group I and in 100% of patients in group II. PVAI was performed in all patients, with right atrial flutter ablation in 7 patients in group I and in 4 patients in group II. Over a mean follow-up of 15 +/- 4 months, group I had higher short-term (18% vs 13%, P = 0.77) and long-term recurrence (24% vs 18%, P = 0.6) than group II. There was no significant difference in the perioperative complications between the two groups. Echocardiography at 3 months showed interatrial communication in 2 patients in group I and 1 patient in group II, which resolved at 12 months. Percutaneous AF ablation using double transseptal access is feasible, safe, and efficacious in patients with ASD and PFO repairs.

  6. The influence of bracket design on frictional losses in the bracket/arch wire system.

    PubMed

    Schumacher, H A; Bourauel, C; Drescher, D

    1999-01-01

    In arch guided tooth movement, the essential role played by bracket configuration with respect to sliding friction has been recognized by the manufacturers, a fact which has had an increasing impact on the design and marketing of new bracket models in recent years. The aim of the present in-vitro study was to investigate the influence of different bracket designs on sliding mechanics. Five differently shaped stainless steel brackets (Discovery: Dentaurum, Damon SL: A-Company, Synergy: Rocky Mountain Orthodontics, Viazis bracket and Omni Arch appliance: GAC) were compared in the 0.022"-slot system. The Orthodontic Measurement and Simulation System (OMSS) was used to quantify the difference between applied force (NiTi coil spring, 1.0 N) and orthodontically effective force and to determine leveling losses occurring during the sliding process in arch guided tooth movement. Simulated canine retraction was performed using continuous arch wires with the dimensions 0.019" x 0.025" (Standard Steel, Unitek) and 0.020" x 0.020" (Ideal Gold, GAC). Comparison of the brackets revealed friction-induced losses ranging from 20 to 70%, with clear-cut advantages resulting from the newly developed bracket types. However, an increased tendency towards leveling losses in terms of distal rotation (maximum 15 degrees) or buccal root torque (maximum 20 degrees) was recorded, especially with those brackets giving the arch wire increased mobility due to their shaping or lack of ligature wire.

  7. Broadband Venetian-Blind Polarizer With Dual Vanes

    NASA Technical Reports Server (NTRS)

    Conroy, Bruce L.; Hoppe, Daniel J.

    1995-01-01

    Improved venetian-blind polarizer features optimized tandem, two-layer vane configuration reducing undesired reflections and deformation of radiation pattern below those of prior single-layer vane configuration. Consists of number of thin, parallel metal strips placed in path of propagating radio-frequency beam. Offers simple way to convert polarization from linear to circular or from circular to linear. Particularly useful for beam-wave-guide applications.

  8. Modelling and restoration of ultrasonic phased-array B-scan images.

    PubMed

    Ardouin, J P; Venetsanopoulos, A N

    1985-10-01

    A model is presented for the radio-frequency image produced by a B-scan (pulse-echo) ultrasound imaging system using a phased-array transducer. This type of scanner is widely used for real-time heart imaging. The model allows for dynamic focusing as well as an acoustic lens focusing the beam in the elevation plane. A result of the model is an expression to compute the space-variant point spread function (PSF) of the system. This is made possible by the use of a combination of Fresnel and Fraunhoffer approximations which are valid in the range of interest for practical applications. The PSF is used to design restoration filters in order to improve image resolution. The filters are then applied to experimental images of wires.

  9. Frequency modulation system test procedure shuttle task 501 approach and landing test configuration

    NASA Technical Reports Server (NTRS)

    Doland, G. D.

    1976-01-01

    Shuttle Task 501 is an in-line task to test the performance and compatibility of radiofrequency links between the SSO and ground, and relay via a satellite. Under Shuttle Task 501 approach and landing test (ALT) phase only a limited portion of the communication and tracking (C&T) equipment is to be tested. The principal item to be tested is a frequency modulated (FM) data link. To test this RF link, an ALT FM System was designed, constructed, and the console wiring verified. A step-by-step procedure to be used to perform the ALT FM system is presented. The ALT FM system test is to be performed prior to delivery of the equipment to the Electronic Systems Test Laboratory (ESTL).

  10. What is harmful for male fertility: cell phone or the wireless Internet?

    PubMed

    Yildirim, Mehmet Erol; Kaynar, Mehmet; Badem, Huseyin; Cavis, Mucahıt; Karatas, Omer Faruk; Cimentepe, Ersın

    2015-09-01

    In this study, we aimed to assess the potential harmful effects of radiofrequency-electromagnetic radiation on sperm parameters. We requested semen for analyses from the male patients coming to our infertility division and also asked them to fill out an anonymous questionnaire. We queried their mobile phone and wireless Internet usage frequencies in order to determine their radiofrequency-electromagnetic radiation exposure. A total of 1082 patients filled the questionnaire but 51 of them were excluded from the study because of azoospermia. There was no significant difference between sperm counts and sperm morphology excluding sperm motility, due to mobile phone usage period, (p = 0.074, p = 0.909, and p = 0.05, respectively). The total motile sperm count and the progressive motile sperm count decreased due to the increase of internet usage (p = 0.032 and p = 0.033, respectively). In line with the total motile sperm count, progressive motile sperm count also decreased with wireless Internet usage compared with the wired Internet connection usage (p = 0.009 and p = 0.018, respectively). There was a negative correlation between wireless Internet usage duration and the total sperm count (r = -0.089, p = 0.039). We have also explored the negative effect of wireless Internet use on sperm motility according to our preliminary results. Copyright © 2015. Published by Elsevier Taiwan.

  11. The benefit of tissue contact monitoring with an electrical coupling index during ablation of typical atrial flutter--a prospective randomised control trial.

    PubMed

    Jones, Michael A; Webster, David; Wong, Kelvin C K; Hayes, Christopher; Qureshi, Norman; Rajappan, Kim; Bashir, Yaver; Betts, Timothy R

    2014-12-01

    We sought to investigate the use of tissue contact monitoring by means of the electrical coupling index (ECI) in a prospective randomised control trial of patients undergoing cavotricuspid isthmus (CTI) ablation for atrial flutter. Patients with ECG-documented typical flutter undergoing their first CTI ablation were randomised to ECI™-guided or non-ECI™-guided ablation. An irrigated-tip ablation catheter was used in all cases. Consecutive 50-W, 60-s radiofrequency lesions were applied to the CTI, from the tricuspid valve to inferior vena cava, with no catheter movement permitted during radiofrequency (RF) delivery. The ablation endpoint was durable CTI block at 20 min post-ablation. Patients underwent routine clinic follow-up post-operatively. A total of 101 patients (79 male), mean age 66 (+/-11), 50 ECI-guided and 51 control cases were enrolled in the study. CTI block was achieved in all. There were no acute complications. All patients were alive at follow-up. CTI block was achieved in a single pass in 36 ECI-guided and 30 control cases (p = 0.16), and at 20 min post-ablation, re-conduction was seen in 5 and 12 cases, respectively (p = 0.07). There was no significant difference in total procedure time (62.7 ± 33 vs. 62.3 ± 33 min, p = 0.92), RF requirement (580 ± 312 vs. 574 ± 287 s, p = 0.11) or fluoroscopy time (718 ± 577 vs. 721 ± 583 s, p = 0.78). After 6 ± 4 months, recurrence of flutter had occurred in 1 (2 %) ECI vs. 8 (16 %) control cases (OR 0.13, 95 % CI 0.01-1.08, p = 0.06). ECI-guided CTI ablation demonstrated a non-statistically significant reduction in late recurrence of atrial flutter, at no cost to procedural time, radiation exposure or RF requirement.

  12. Electrostatic wire for stabilizing a charged particle beam

    DOEpatents

    Prono, Daniel S.; Caporaso, George J.; Briggs, Richard J.

    1985-01-01

    In combination with a charged particle beam generator and accelerator, apparatus and method are provided for stabilizing a beam of electrically charged particles. A guiding means, disposed within the particle beam, has an electric charge induced upon it by the charged particle beam. Because the sign of the electric charge on the guiding means and the sign of the particle beam are opposite, the particles are attracted toward and cluster around the guiding means to thereby stabilize the particle beam as it travels.

  13. Electrostatic wire stabilizing a charged particle beam

    DOEpatents

    Prono, D.S.; Caporaso, G.J.; Briggs, R.J.

    1983-03-21

    In combination with a charged particle beam generator and accelerator, apparatus and method are provided for stabilizing a beam of electrically charged particles. A guiding means, disposed within the particle beam, has an electric charge induced upon it by the charged particle beam. Because the sign of the electric charge on the guiding means and the sign of the particle beam are opposite, the particles are attracted toward and cluster around the guiding means to thereby stabilize the particle beam as it travels.

  14. Sacroiliac Joint Interventions.

    PubMed

    Soto Quijano, David A; Otero Loperena, Eduardo

    2018-02-01

    Sacroiliac joint (SIJ) pain is an important cause of lower back problems. Multiple SIJ injection techniques have been proposed over the years to help in the diagnosis and treatment of this condition. However, the SIJ innervation is complex and variable, and truly intra-articular injections are sometimes difficult to obtain. Different sacroiliac joint injections have shown to provide pain relief in patients suffering this ailment. Various techniques for intraarticular injections, sacral branch blocks and radiofrequency ablation, both fluoroscopy guided and ultrasound guided are discussed in this paper. Less common techniques like prolotherapy, platelet rich plasma injections and botulism toxin injections are also discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Random vibration (stress screening) of printed wiring assemblies

    NASA Technical Reports Server (NTRS)

    Bastien, Gilbert J.

    1988-01-01

    The results of a random vibration test screening (RVSS) study of the determination of the upper and lower vibration limits on printed wiring assemblies (PWA) are summarized. The study results are intended to serve as a guide for engineers and designers who make decisions on PWA features that need to withstand the stresses of dynamic testing and screening. The maximum allowable PWA deflection, G levels, and PSD levels are compared to the expected or actual levels to determine if deleterious effects will occur.

  16. Terahertz generation from laser-driven ultrafast current propagation along a wire target.

    PubMed

    Zhuo, H B; Zhang, S J; Li, X H; Zhou, H Y; Li, X Z; Zou, D B; Yu, M Y; Wu, H C; Sheng, Z M; Zhou, C T

    2017-01-01

    Generation of intense coherent THz radiation by obliquely incidenting an intense laser pulse on a wire target is studied using particle-in-cell simulation. The laser-accelerated fast electrons are confined and guided along the surface of the wire, which then acts like a current-carrying line antenna and under appropriate conditions can emit electromagnetic radiation in the THz regime. For a driving laser intensity ∼3×10^{18}W/cm^{2} and pulse duration ∼10 fs, a transient current above 10 KA is produced on the wire surface. The emission-cone angle of the resulting ∼0.15 mJ (∼58 GV/m peak electric field) THz radiation is ∼30^{∘}. The conversion efficiency of laser-to-THz energy is ∼0.75%. A simple analytical model that well reproduces the simulated result is presented.

  17. Multicentre experience with the BridgePoint devices to facilitate recanalisation of chronic total coronary occlusions through controlled subintimal re-entry.

    PubMed

    Werner, Gerald S; Schofer, Joachim; Sievert, Horst; Kugler, Chad; Reifart, Nicolaus J

    2011-06-01

    The major challenge for the interventional treatment of chronic total coronary occlusion (CTO) is a low primary success rate. A common problem is the passage of the recanalisation wire into a subintimal position. New devices, which were evaluated in the first multicentre study in CTOs resistant to a conventional wire approach, may help to facilitate a controlled re-entry into the true lumen. The aim of this study was to assess the safety and efficacy of this approach, with successful true lumen distal wire passage as the primary endpoint. Forty-two patients were enrolled in four centres with high expertise in PCI for CTOs. All CTOs were of at least three months duration, and were initially attempted with dedicated recanalisation wires. After failure to pass or creation of a subintimal dissection, the BridgePoint devices were applied, consisting of a ball-tipped catheter (CrossBoss) to pass the proximal occlusion cap, and a flat-shaped balloon catheter (Stingray catheter) to be inflated within the subintimal space to guide the re-entry into the true vessel lumen with a special wire (Stingray guidewire). The primary endpoint was met in 67% of all patients. A higher success rate seemed to be possible when all devices were used in sequenced beginning with the CrossBoss, and in the case of a subintimal passage, followed by the Stingray. True lumen re-entry failed because of the loss of distally contrast filling and thus loss of a target for re-entry, and by a failure to advance the Stingray balloon far enough distal and parallel to the distal lumen. There were no severe device related complications. In patients with complex CTOs referred to dedicated centres with high experience in CTOs, these results demonstrate the potential of a guided re-entry from a subintimal wire position by use of the BridgePoint devices.

  18. Explosion symmetry improvement of polyimide-coated tungsten wire in vacuum on negative discharge facility

    NASA Astrophysics Data System (ADS)

    Li, Mo; Wu, Jian; Lu, Yihan; Li, Xingwen; Li, Yang; Qiu, Mengtong

    2018-01-01

    Tungsten wire explosion is very asymmetric when fast current rate and insulated coatings are both applied on negative discharge facility using a 24-mm-diameter cathode geometry, which is commonly used on mega-ampere facilities. It is inferred, based on an analytical treatment of the guiding center drift and COMSOL simulations, that the large negative radial electric field causes early voltage breakdown and terminates energy deposition into the wire core on the anode side of the wire. After the anode side is short circuited, the radial electric field along the wire surface on the cathode side will change its polarity and thus leading to additional energy deposition into the wire core. This change causes ˜10 times larger energy deposition and ˜14 times faster explosion velocity in the cathode side than the anode side. In order to reduce this asymmetry, a hollow cylindrical cathode geometry was used to reverse the polarity of radial electric field and was optimized to use on multi-MA facilities. In this case, fully vaporized polyimide-coated tungsten wire with great symmetry improvement was achieved with energy deposition of ˜8.8 eV/atom. The atomic and electronic density distributions for the two different load geometries were obtained by the double-wavelength measurement.

  19. Plasmonic mode converter for controlling optical impedance and nanoscale light-matter interaction.

    PubMed

    Hung, Yun-Ting; Huang, Chen-Bin; Huang, Jer-Shing

    2012-08-27

    To enable multiple functions of plasmonic nanocircuits, it is of key importance to control the propagation properties and the modal distribution of the guided optical modes such that their impedance matches to that of nearby quantum systems and desired light-matter interaction can be achieved. Here, we present efficient mode converters for manipulating guided modes on a plasmonic two-wire transmission line. The mode conversion is achieved through varying the path length, wire cross section and the surrounding index of refraction. Instead of pure optical interference, strong near-field coupling of surface plasmons results in great momentum splitting and modal profile variation. We theoretically demonstrate control over nanoantenna radiation and discuss the possibility to enhance nanoscale light-matter interaction. The proposed converter may find applications in surface plasmon amplification, index sensing and enhanced nanoscale spectroscopy.

  20. Improved Image-Guided Laparoscopic Prostatectomy

    DTIC Science & Technology

    2012-08-01

    prevalent technique used in widening the field of view (FOV) of medical ultrasound images. Also referred to as stitching or panorama , the ultra- sound mosaic...tissue which can add valu- able features to the B-mode panorama . Many clinical applications deal with large cancerous lesions which expand beyond the...1999) 203–233 2. Varghese, T., Zagzebski, J., Lee Jr., F.: Elastographic imaging of thermal lesions in the liver in vivo following radiofrequency

  1. Percutaneous treatment of intervertebral disc herniation.

    PubMed

    Buy, Xavier; Gangi, Afshin

    2010-06-01

    Interventional radiology plays a major role in the management of symptomatic intervertebral disc herniations. In the absence of significant pain relief with conservative treatment including oral pain killers and anti-inflammatory drugs, selective image-guided periradicular infiltrations are generally indicated. The precise control of needle positioning allows optimal distribution of steroids along the painful nerve root. After 6 weeks of failure of conservative treatment including periradicular infiltration, treatment aiming to decompress or remove the herniation is considered. Conventional open surgery offers suboptimal results and is associated with significant morbidity. To achieve minimally invasive discal decompression, different percutaneous techniques have been developed. Their principle is to remove a small volume of nucleus, which results in an important reduction of intradiscal pressure and subsequently reduction of pressure inside the disc herniation. However, only contained disc herniations determined by computed tomography or magnetic resonance are indicated for these techniques. Thermal techniques such as radiofrequency or laser nucleotomy seem to be more effective than purely mechanical nucleotomy; indeed, they achieve discal decompression but also thermal destruction of intradiscal nociceptors, which may play a major role in the physiopathology of discal pain. The techniques of image-guided spinal periradicular infiltration and percutaneous nucleotomy with laser and radiofrequency are presented with emphasis on their best indications.

  2. Comparison between ultrasound-guided interfascial pulsed radiofrequency and ultrasound-guided interfascial block with local anesthetic in myofascial pain syndrome of trapezius muscle

    PubMed Central

    Cho, Ik Tae; Cho, Yun Woo; Kwak, Sang Gyu; Chang, Min Cheol

    2017-01-01

    Abstract Myofascial pain syndrome (MPS) of the trapezius muscle (TM) is a frequently occurring musculoskeletal disorder. However, the treatment of MPS of the TM remains a challenge. We investigated the effects of ultrasound (US)-guided pulsed radiofrequency (PRF) stimulation on the interfascial area of the TM. In addition, we compared its effect with that of interfascial block (IFB) with 10 mL of 0.6% lidocaine on the interfascial area of the TM. Thirty-six patients with MPS of the TM were included and randomly assigned into 2 groups. Eighteen patients underwent PRF stimulation on the interfascial area of the TM (PRF group) and 18 patients underwent IFB with lidocaine on the same area (IFB group). Pain intensity was evaluated using a numerical rating scale (NRS) at pretreatment, 2, 4, and 8 weeks after treatment. At pretreatment and 8 weeks after treatment, quality of life was assessed using the Short Form-36 Health Survey (SF-36), which includes the physical component score (PCS) and the mental component score (MCS). One patient in the PRF group was lost to follow-up. Patients in both groups showed a significant decrease in NRS scores at 2, 4, and 8 weeks after treatments and a significant increase in PCS and MCS of the SF-36 at 8 weeks after treatments. Two weeks after each treatment, the decrements of NRS scores were not significantly different between the 2 groups. However, 4 and 8 weeks after the procedures, we found that the NRS score was significantly lower in the PRF group than in the IFB group. At 8 weeks after the treatments, PCS and MCS of the SF-36 in the PRF group were significantly higher than those in the IFB group. For the management of MPS of the TM, US-guided interfascial PRF had a better long-term effect on reducing the pain and the quality of life compared to US-guided IFB. Therefore, we think US-guided PRF stimulation on the interfascial area of the TM can be a beneficial alternative to manage the pain following MPS of the TM. PMID:28151904

  3. Comparison between ultrasound-guided interfascial pulsed radiofrequency and ultrasound-guided interfascial block with local anesthetic in myofascial pain syndrome of trapezius muscle.

    PubMed

    Cho, Ik Tae; Cho, Yun Woo; Kwak, Sang Gyu; Chang, Min Cheol

    2017-02-01

    Myofascial pain syndrome (MPS) of the trapezius muscle (TM) is a frequently occurring musculoskeletal disorder. However, the treatment of MPS of the TM remains a challenge. We investigated the effects of ultrasound (US)-guided pulsed radiofrequency (PRF) stimulation on the interfascial area of the TM. In addition, we compared its effect with that of interfascial block (IFB) with 10 mL of 0.6% lidocaine on the interfascial area of the TM. Thirty-six patients with MPS of the TM were included and randomly assigned into 2 groups. Eighteen patients underwent PRF stimulation on the interfascial area of the TM (PRF group) and 18 patients underwent IFB with lidocaine on the same area (IFB group). Pain intensity was evaluated using a numerical rating scale (NRS) at pretreatment, 2, 4, and 8 weeks after treatment. At pretreatment and 8 weeks after treatment, quality of life was assessed using the Short Form-36 Health Survey (SF-36), which includes the physical component score (PCS) and the mental component score (MCS). One patient in the PRF group was lost to follow-up. Patients in both groups showed a significant decrease in NRS scores at 2, 4, and 8 weeks after treatments and a significant increase in PCS and MCS of the SF-36 at 8 weeks after treatments. Two weeks after each treatment, the decrements of NRS scores were not significantly different between the 2 groups. However, 4 and 8 weeks after the procedures, we found that the NRS score was significantly lower in the PRF group than in the IFB group. At 8 weeks after the treatments, PCS and MCS of the SF-36 in the PRF group were significantly higher than those in the IFB group. For the management of MPS of the TM, US-guided interfascial PRF had a better long-term effect on reducing the pain and the quality of life compared to US-guided IFB. Therefore, we think US-guided PRF stimulation on the interfascial area of the TM can be a beneficial alternative to manage the pain following MPS of the TM.

  4. Rare complications after lung percutaneous radiofrequency ablation: Incidence, risk factors, prevention and management.

    PubMed

    Alberti, Nicolas; Buy, Xavier; Frulio, Nora; Montaudon, Michel; Canella, Mathieu; Gangi, Afshin; Crombe, Amandine; Palussière, Jean

    2016-06-01

    Among image-guided thermo-ablative techniques, percutaneous radiofrequency ablation (PRFA) is the most widely used technique for the treatment of primary and secondary lung malignancies. Tolerance of PRFA in the lung is excellent. However, relatively little is known about potential rare complications. This article presents both the clinical and imaging features of lung PRFA complications as well as their prevention and management. Complications may be classified in four groups: pleuropulmonary (e.g., bronchopleural or bronchial fistula, delayed abscess or aspergilloma inside post-PRFA cavitations, pulmonary artery pseudo aneurysm, gas embolism and interstitial pneumonia); thoracic wall and vertebral (e.g., rib or vertebral fractures and intercostal artery injury); mediastinal and apical (e.g., neural damage); or diaphragmatic. Most complications can be managed with conservative treatment, percutaneous or endoscopic drainage, or surgical repair. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. 23 Lung Metastases Treated by Radiofrequency Ablation Over 10 Years in a Single Patient: Successful Oncological Outcome of a Metastatic Cancer Without Altered Respiratory Function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crombé, Amandine, E-mail: amandine.crombe@ens-lyon.fr; Buy, Xavier; Godbert, Yann

    An 82-year-old man, who was diagnosed in 2002 with an oncocytic (Hürthle cell) thyroid carcinoma, was initially treated by local surgery and was refractory to radioiodine treatment. The patient had successive secondary recurrences from 2006 onwards. Metastases were suspected due to an elevation of thyroglobulin in serum. Hypermetabolic nodules were targeted using FDG PET as well as CT-guided radiofrequency ablations. Thyroglobulin levels decreased following each procedure. 10 years later, tolerance and efficacy are excellent; 23 lung metastases have been treated during 11 sessions without current relapse. Respiratory function and quality of life are not altered. This report illustrates how radiofrequencymore » ablation can be efficiently integrated into the long-term management of poorly aggressive oligometastatic cancer, in combination with other local and/or systemic therapies.« less

  6. [Radiofrequency ablation of hepatocellular carcinoma].

    PubMed

    Widmann, Gerlig; Schullian, Peter; Bale, Reto

    2013-03-01

    Percutaneous radiofrequency ablation (RFA) is well established in the treatment of hepatocellular carcinoma (HCC). Due to its curative potential, it is the method of choice for non resectable BCLC (Barcelona Liver Clinic) 0 and A. RFA challenges surgical resection for small HCC and is the method of choice in bridging for transplantation and recurrence after resection or transplantation. The technical feasibility of RFA depends on the size and location of the HCC and the availability of ablation techniques (one needle techniques, multi-needle techniques). More recently, stereotactic multi-needle techniques with 3D trajectory planning and guided needle placement substantially improve the spectrum of treatable lesions including large volume tumors. Treatment success depends on the realization of ablations with large intentional margins of tumor free tissue (A0 ablation in analogy to R0 resection), which has to be documented by fusion of post- with pre-ablation images, and confirmed during follow-up imaging.

  7. Evaluation of multilayer printed wiring boards by metallographic techniques: An illustrated guide to the preparation and inspection of plated-through hole test coupons based on the requirements of Mil-P-55110D

    NASA Technical Reports Server (NTRS)

    Jellison, J.

    1986-01-01

    This work is an illustrated handbook containing the rationale and procedure for the evaluation of multilayer printed wiring board construction integrity with respect to plated-through holes in accordance with the requirements of MIL-P-55110D, Printed Wiring Boards. It is intended as a practical aid for those concerned with determining the construction integrity of multilayer boards for high reliability applications. Photomicrographs of cross sectioned holes illustrate defect types, acceptable and unacceptable conditions, and methods of measurement. A procedure for specimen preparation is given, and appropriate paragraphs of the military specification are included and explained.

  8. Welding skate with computerized controls

    NASA Technical Reports Server (NTRS)

    Wall, W. A., Jr.

    1968-01-01

    New welding skate concept for automatic TIG welding of contoured or double-contoured parts combines lightweight welding apparatus with electrical circuitry which computes the desired torch angle and positions a torch and cold-wire guide angle manipulator.

  9. The Effectiveness and Risks of Fluoroscopically-Guided Cervical Medial Branch Thermal Radiofrequency Neurotomy: A Systematic Review with Comprehensive Analysis of the Published Data.

    PubMed

    Engel, Andrew; Rappard, George; King, Wade; Kennedy, David J

    2016-04-01

    To determine the effectiveness and risks of fluoroscopically-guided cervical medial branch thermal radiofrequency neurotomy (CMBTRFN) for treating chronic neck pain of zygapophysial joint origin. Systematic review of the literature with comprehensive analysis of the published data. Four reviewers formally trained in evidence-based medicine searched the literature on CMBTRFN. Each assessed the methodologies of studies found and appraised the quality of evidence presented. The primary outcomes assessed were 100% relief of pain 6 and 12 months after treatment. Other outcomes were noted if reported. The evidence was evaluated in accordance with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) system. The searches yielded eight primary publications on the effectiveness of the procedure. The evidence shows a majority of patients were pain free at 6 months and over a third were pain free at 1 year. The number needed to treat for complete pain relief at 6 months is 2. The evidence of effectiveness is of high quality according to the GRADE system. Twelve papers were found reporting unwanted effects, most of which are minor and temporary. No serious complications have ever been reported from procedures performed according to the published guidelines. The evidence of risks is of low quality according to the GRADE system. If performed as described in the International Spine Intervention Society Guidelines, fluoroscopically-guided CMBTRFN is effective for abolishing zygapophysial joint pain and carries only minor risks. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cazzato, Roberto Luigi, E-mail: r.cazzato@unicampus.it; Buy, Xavier, E-mail: x.buy@bordeaux.unicancer.fr; Alberti, Nicolas, E-mail: nicoalbertibdx@gmail.com

    2015-02-15

    PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize themore » tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.« less

  11. Visualization of risk structures for interactive planning of image guided radiofrequency ablation of liver tumors

    NASA Astrophysics Data System (ADS)

    Rieder, Christian; Schwier, Michael; Weihusen, Andreas; Zidowitz, Stephan; Peitgen, Heinz-Otto

    2009-02-01

    Image guided radiofrequency ablation (RFA) is becoming a standard procedure as a minimally invasive method for tumor treatment in the clinical routine. The visualization of pathological tissue and potential risk structures like vessels or important organs gives essential support in image guided pre-interventional RFA planning. In this work our aim is to present novel visualization techniques for interactive RFA planning to support the physician with spatial information of pathological structures as well as the finding of trajectories without harming vitally important tissue. Furthermore, we illustrate three-dimensional applicator models of different manufactures combined with corresponding ablation areas in homogenous tissue, as specified by the manufacturers, to enhance the estimated amount of cell destruction caused by ablation. The visualization techniques are embedded in a workflow oriented application, designed for the use in the clinical routine. To allow a high-quality volume rendering we integrated a visualization method using the fuzzy c-means algorithm. This method automatically defines a transfer function for volume visualization of vessels without the need of a segmentation mask. However, insufficient visualization results of the displayed vessels caused by low data quality can be improved using local vessel segmentation in the vicinity of the lesion. We also provide an interactive segmentation technique of liver tumors for the volumetric measurement and for the visualization of pathological tissue combined with anatomical structures. In order to support coagulation estimation with respect to the heat-sink effect of the cooling blood flow which decreases thermal ablation, a numerical simulation of the heat distribution is provided.

  12. Hybrid laparoscopic and robotic ultrasound-guided radiofrequency ablation-assisted clampless partial nephrectomy.

    PubMed

    Nadler, Robert B; Perry, Kent T; Smith, Norm D

    2009-07-01

    To describe a clampless approach made possible by creating an avascular plane of tissue with radiofrequency ablation. Laparoscopic partial nephrectomy is slowly gaining acceptance as a method to treat small (<4 cm) and select moderate (<7 cm) renal masses. The intricacies of laparoscopic suturing, which result in prolonged warm ischemia times, have delayed the widespread acceptance of this technique among urologists. Laparoscopic suturing to close the collecting system was done using the da Vinci robot. An avascular plane of tissue from coagulation necrosis was achieved with the Habib 4X radiofrequency ablation device and the Rita 1500X generator. Typically, we used a power setting of 50 W but have found settings as low as 25 W necessary to provide hemostasis for larger vessels. The tumor was then sharply excised with a negative margin using robotic scissors and electrocautery to facilitate tissue cutting. Retrograde injection of methylthioninium chloride and saline through an externalized ureteral catheter allowed for precise sutured closure of the collecting system. FloSeal and BioGlue were then applied, making surgical bolsters or parenchymal sutures unnecessary. Intraoperative histologic evaluation of the surgical margin and repeat resection of the tumor bed was possible because the renal hilum was not clamped, and no warm ischemia was used. This technique, which combines the improving technologies of robotic surgery, intraoperative laparoscopic ultrasonography, and radiofrequency ablation, might make more surgeons comfortable with the intricacies of laparoscopic suturing and eliminate prolonged warm ischemia times. Overall, this method should result in more patients being able to undergo minimally invasive laparoscopic partial nephrectomy.

  13. Positioning and joining of organic single-crystalline wires

    PubMed Central

    Wu, Yuchen; Feng, Jiangang; Jiang, Xiangyu; Zhang, Zhen; Wang, Xuedong; Su, Bin; Jiang, Lei

    2015-01-01

    Organic single-crystal, one-dimensional materials can effectively carry charges and/or excitons due to their highly ordered molecule packing, minimized defects and eliminated grain boundaries. Controlling the alignment/position of organic single-crystal one-dimensional architectures would allow on-demand photon/electron transport, which is a prerequisite in waveguides and other optoelectronic applications. Here we report a guided physical vapour transport technique to control the growth, alignment and positioning of organic single-crystal wires with the guidance of pillar-structured substrates. Submicrometre-wide, hundreds of micrometres long, highly aligned, organic single-crystal wire arrays are generated. Furthermore, these organic single-crystal wires can be joined within controlled angles by varying the pillar geometries. Owing to the controllable growth of organic single-crystal one-dimensional architectures, we can present proof-of-principle demonstrations utilizing joined wires to allow optical waveguide through small radii of curvature (internal angles of ~90–120°). Our methodology may open a route to control the growth of organic single-crystal one-dimensional materials with potential applications in optoelectronics. PMID:25814032

  14. Horizontal Advanced Tensiometer

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2004-06-22

    An horizontal advanced tensiometer is described that allows the monitoring of the water pressure of soil positions, particularly beneath objects or materials that inhibit the use of previous monitoring wells. The tensiometer includes a porous cup, a pressure transducer (with an attached gasket device), an adaptive chamber, at least one outer guide tube which allows access to the desired horizontal position, a transducer wire, a data logger and preferably an inner guide tube and a specialized joint which provides pressure on the inner guide tube to maintain the seal between the gasket of the transducer and the adaptive chamber.

  15. Radiofrequency ablation of chondroblastoma using a multi-tined expandable electrode system: initial results.

    PubMed

    Tins, Bernhard; Cassar-Pullicino, Victor; McCall, Iain; Cool, Paul; Williams, David; Mangham, David

    2006-04-01

    The standard treatment for chondroblastoma is surgery, which can be difficult and disabling due to its apo- or epiphyseal location. Radiofrequency (RF) ablation potentially offers a minimally invasive alternative. The often large size of chondroblastomas can make treatment with plain electrode systems difficult or impossible. This article describes the preliminary experience of RF treatment of chondroblastomas with a multi-tined expandable RF electrode system. Four cases of CT guided RF treatment are described. The tumour was successfully treated in all cases. In two cases, complications occurred; infraction of a subarticular chondroblastoma in one case and cartilage and bone damage in the unaffected compartment of a knee joint in the other. Radiofrequency treatment near a joint surface threatens the integrity of cartilage and therefore long-term joint function. In weight-bearing areas, the lack of bone replacement in successfully treated lesions contributes to the risk of mechanical failure. Multi-tined expandable electrode systems allow the treatment of large chondroblastomas. In weight-bearing joints and lesions near to the articular cartilage, there is a risk of cartilage damage and mechanical weakening of the bone. In lesions without these caveats, RF ablation appears promising. The potential risks and benefits need to be evaluated for each case individually.

  16. PERCUTANEOUS RADIOFREQUENCY ASSISTED LIVER PARTITION WITH PORTAL VEIN EMBOLIZATION FOR STAGED HEPATECTOMY (PRALPPS).

    PubMed

    Giménez, Mariano E; Houghton, Eduardo J; Davrieux, C Federico; Serra, Edgardo; Pessaux, Patrick; Palermo, Mariano; Acquafresca, Pablo A; Finger, Caetano; Dallemagne, Bernard; Marescaux, Jacques

    2018-03-01

    When a major hepatic resection is necessary, sometimes the future liver remnant is not enough to maintain sufficient liver function and patients are more likely to develop liver failure after surgery. To test the hypothesis that performing a percutaneous radiofrecuency liver partition plus percutaneous portal vein embolization (PRALPPS) for stage hepatectomy in pigs is feasible. Four pigs (Sus scrofa domesticus) both sexes with weights between 25 to 35 kg underwent percutaneous portal vein embolization with coils of the left portal vein. By contrasted CT, the difference between the liver parenchyma corresponding to the embolized zone and the normal one was identified. Immediately, using the fusion of images between ultrasound and CT as a guide, radiofrequency needles were placed percutaneouslyand then ablated until the liver partition was complete. Finally, hepatectomy was completed with a laparoscopic approach. All animals have survived the procedures, with no reported complications. The successful portal embolization process was confirmed both by portography and CT. In the macroscopic analysis of the pieces, the depth of the ablation was analyzed. The hepatic hilum was respected. On the other hand, the correct position of the embolization material on the left portal vein could be also observed. "Percutaneous radiofrequency assisted liver partition with portal vein embolization" (PRALLPS) is a feasible procedure.

  17. Mode Matching for Optical Antennas

    NASA Astrophysics Data System (ADS)

    Feichtner, Thorsten; Christiansen, Silke; Hecht, Bert

    2017-11-01

    The emission rate of a point dipole can be strongly increased in the presence of a well-designed optical antenna. Yet, optical antenna design is largely based on radio-frequency rules, ignoring, e.g., Ohmic losses and non-negligible field penetration in metals at optical frequencies. Here, we combine reciprocity and Poynting's theorem to derive a set of optical-frequency antenna design rules for benchmarking and optimizing the performance of optical antennas driven by single quantum emitters. Based on these findings a novel plasmonic cavity antenna design is presented exhibiting a considerably improved performance compared to a reference two-wire antenna. Our work will be useful for the design of high-performance optical antennas and nanoresonators for diverse applications ranging from quantum optics to antenna-enhanced single-emitter spectroscopy and sensing.

  18. A broadband ASE light source-based full-duplex FTTX/ROF transport system.

    PubMed

    Chang, Ching-Hung; Lu, Hai-Han; Su, Heng-Sheng; Shih, Chien-Liang; Chen, Kai-Jen

    2009-11-23

    A full-duplex fiber-to-the-X (FTTX)/radio-over-fiber (ROF) transport system based on a broadband amplified spontaneous emission (ASE) light source is proposed and demonstrated for rural wide-spread villages. Combining the concepts of long-transmission transmission and ring topology, a long-haul single-mode fiber (SMF) trunk is sharing with multiple rural villages. Externally modulated baseband (BB) (1.25 Gbps) and radio-frequency (RF) (622 Mbps/10 GHz) signals are successfully transmitted simultaneously. Good bit error rate (BER) performance was achieved to demonstrate the practice of providing wire/wireless connections for long-haul wide-spread rural villages. Since our proposed system uses only a broadband ASE light source to achieve multi-wavelengths transmissions, it also reveals an outstanding one with simpler and more economic advantages.

  19. [Echo-guided radiofrequency percutaneous ablation of hepatocellular carcinoma in cirrhosis using a cooled needle].

    PubMed

    Marone, G; Francica, G; D'Angelo, V; Iodice, G; Pastore, P; Altamura, G; Cusati, B; Siani, A

    1998-06-01

    Radiofrequency hyperthermia using the newly-developed "cooled-tip" needle is one of the latest US-guided percutaneous treatments of hepatocellular carcinoma arising in cirrhosis. The continuous cooling of the needle tip allows tissue heating and necrosis far from the electrode without tissue charring, which was the major drawback of the old monopolar technique. Herein we report our preliminary results on feasibility and effectiveness of the thermoablation of mono- or paucifocal hepatocellular carcinoma with the cooled-tip needle. November, 1996, to January, 1998, we treated thirteen cirrhotic patients (mean age 69.5 yrs, 10 men, 12 HCV-positive; 11 in Child's Class A and 2 in Class B) with 19 hepatocellular carcinoma nodules (mean diameter: 27 mm; range: 10-41 mm; 6 with diameter > 3 cm). None of the patients had portal thrombosis and/or extrahepatic spread. We used a radiofrequency generator (100 W power) connected to an 18 G perfusion electrode needle with an exposed tip of 2-3 cm. The circuit is closed through a dispersive electrode positioned under the patient's thighs. A peristaltic pump infuses a chilled (2-5 degrees C) saline solution to guarantee the continuous cooling of the needle tip. The needle was placed into target lesions under US guidance. The interventional procedure was carried out under general anesthesia using Propofol without intubation. Dynamic CT (more recently with the helical technique) was carried out 15-20 days after thermoablation to assess treatment efficacy. In all, 31 thermal injuries (at 1000-1200 mA for 10-15 minutes) were caused in 21 sessions in the 19 hepatocellular carcinoma nodules (mean: 1.5 lesions per nodule and 1.6 sessions per patient). Complete necrosis as assessed at dynamic CT (no enhancement during the arteriographic phase) was achieved in 16 of 19 nodules (84%). No side-effects occurred. During the follow-up (median: 11 months) no death occurred and five patients had recurrent hepatocellular carcinoma appearing either as single nodule or as multinodular liver involvement. In our experience radiofrequency hyperthermia with the cooled-tip needle permits effective and safe percutaneous ablation of HCC in cirrhosis. In addition, treatment time is short and lesions > 3 cm can be treated. Further experience is needed to better define the role of percutaneous thermoablation in the treatment strategy of hepatocellular carcinoma.

  20. Stents in Renal Artery Bifurcation Stenosis: A Case Report

    PubMed Central

    Leonardou, Polytimi; Pappas, Paris

    2011-01-01

    A 39-year-old patient presented with poorly controlled hypertension, and she was referred to renal angiogram and potential renal angioplasty. Renal angiogram showed a bifurcation lesion of the right renal artery. A guide wire was used to cross the upper branch, while the lower branch was protected by another same-type guide wire through the same introducer. Two thin monorail balloons were used to dilate the two branches; however, despite balloon dilatation, the stenosis of the vessels persisted. The “kissing balloon” technique was then attempted by simultaneously inflating both branches using the same balloons, but more than a 70% residual stenosis persisted in each branch. Two stents were finally placed in a “kissing” way through the main renal artery. The imaging and clinical results were good, without any procedure-related complications. Three years clinical followup was also good, without any reason for further interventional approach. PMID:21789043

  1. [Methods of resolution for haptic assistance during catheterization].

    PubMed

    Kern, T A; Herrmann, J; Klages, S; Meiss, T; Werthschützky, R

    2005-01-01

    During catheterization navigation within the patient is mainly dependent on a live x-ray image on the screen. Although methods for 3D visualisation and remote navigation of the catheter are discussed and tested still precise positioning is merely the result of intense training and a high skill and level of training of the performing surgeon. This article refers to a system which can be considered as an add-on for existing procedures of catheterization. It compromises of a miniaturised force sensor located at the tip of guide-wires whose prototype is shown here. The measured forces will be presented to the surgeon amplified by an external actuator described in this article. As a result a haptic perception of the forces between the tip of the guide-wire and the vessels walls will be available and enable the surgeon to gain an impression which is comparable to palpation of living vessels from the inside

  2. Ultrasound-Guided Vascular Access Simulator for Medical Training: Proposal of a Simple, Economic and Effective Model.

    PubMed

    Fürst, Rafael Vilhena de Carvalho; Polimanti, Afonso César; Galego, Sidnei José; Bicudo, Maria Claudia; Montagna, Erik; Corrêa, João Antônio

    2017-03-01

    To present a simple and affordable model able to properly simulate an ultrasound-guided venous access. The simulation was made using a latex balloon tube filled with water and dye solution implanted in a thawed chicken breast with bones. The presented model allows the simulation of all implant stages of a central catheter. The obtained echogenicity is similar to that observed in human tissue, and the ultrasound identification of the tissues, balloon, needle, wire guide and catheter is feasible and reproducible. The proposed model is simple, economical, easy to manufacture and capable of realistically and effectively simulating an ultrasound-guided venous access.

  3. Nail-like targets for laser plasma interaction experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pasley, J; Wei, M; Shipton, E

    2007-12-18

    The interaction of ultra-high power picosecond laser pulses with solid targets is of interest both for benchmarking the results of hybrid particle in cell (PIC) codes and also for applications to re-entrant cone guided fast ignition. We describe the construction of novel targets in which copper/titanium wires are formed into 'nail-like' objects by a process of melting and micromachining, so that energy can be reliably coupled to a 24 {micro}m diameter wire. An extreme-ultraviolet image of the interaction of the Titan laser with such a target is shown.

  4. Semi-rigid single hook localization the best method for localizing ground glass opacities during video-assisted thoracoscopic surgery: re-aerated swine lung experimental and primary clinical results

    PubMed Central

    Zhao, Guang; Sun, Long; Geng, Guojun; Liu, Hongming; Li, Ning; Liu, Suhuan; Hao, Bing

    2017-01-01

    Background The aim of this study was to compare the effects of currently available preoperative localization methods, including semi-rigid single hook-wire, double-thorn hook-wire, and microcoil, in localizing the pulmonary nodules, thus to select the best technology to assist video-assisted thoracoscopic surgery (VATS) for small ground glass opacities (GGO). Methods Preoperative CT-guided localizing techniques including semi-rigid single hook-wire, double-thorn hook-wire and microcoil were used in re-aerated fresh swine lung for location experiments. The advantages and drawbacks of the three positioning technologies were compared, and then the most optimal technique was used in patients with GGO. Technical success and post-operative complications were used as primary endpoints. Results All three localizing techniques were successfully performed in the re-aerated fresh swine lung. The median tractive force of semi-rigid single hook wire, double-thorn hook wire and microcoil were 6.5, 4.85 and 0.2 N, which measured by a spring dynamometer. The wound sizes in the superficial pleura, caused by unplugging the needles, were 2 mm in double-thorn hook wire, 1 mm in semi-rigid single hook and 1 mm in microcoil, respectively. In patients with GGOs, the semi-rigid hook wires localizations were successfully performed, without any complication that need to be intervened. Dislodgement was reported in one patient before VATS. No major complications related to the preoperative hook wire localization and VATS were observed. Conclusions We found from our localization experiments in the swine lung that, among the commonly used three localization methods, semi-rigid hook wire showed the best operability and practicability than double-thorn hook wire and microcoil. Preoperative localization of small pulmonary nodules with single semi-rigid hook wire system shows a high success rate, acceptable utility and especially low dislodgement in VATS. PMID:29312722

  5. Emergency cricothyrotomy-a comparative study of different techniques in human cadavers.

    PubMed

    Schober, Patrick; Hegemann, Martina C; Schwarte, Lothar A; Loer, Stephan A; Noetges, Peter

    2009-02-01

    Emergency cricothyrotomy is the final lifesaving option in "cannot intubate-cannot ventilate" situations. Fast, efficient and safe management is indispensable to reestablish oxygenation, thus the quickest, most reliable and safest technique should be used. Several cricothyrotomy techniques exist, which can be grouped into two categories: anatomical-surgical and puncture. We studied success rate, tracheal tube insertion time and complications of different techniques, including a novel cricothyrotomy scissors technique in human cadavers. Sixty-three inexperienced health care providers were randomly assigned to apply either an anatomical-surgical technique (standard surgical technique, n=18; novel cricothyrotomy scissors technique, n=14) or a puncture technique (catheter-over-needle technique, n=17; wire-guided technique, n=14). Airway access was almost always successful with the anatomical-surgical techniques (success rate in standard surgical group 94%, scissors group 100%). In contrast, the success rate was smaller (p<0.05) with the puncture techniques (catheter-over-needle group 82%, wire-guided technique 71%). Tracheal tube insertion time was faster overall (p<0.05) with anatomical-surgical techniques (standard surgical 78s [54-135], novel cricothyrotomy scissors technique 60s [42-82]; median [IQR]) than with puncture techniques (catheter-over-needle technique 74s [48-145], wire-guided technique 135s [116-307]). We observed fewer complications with anatomical-surgical techniques than with puncture techniques (p<0.001). In inexperienced health care personnel, anatomical-surgical techniques showed a higher success rate, a faster tracheal tube insertion time and a lower complication rate compared with puncture techniques, suggesting that they may be the techniques of choice in emergencies.

  6. Effect of bending on the performance of spool-packaged shape memory alloy actuators

    NASA Astrophysics Data System (ADS)

    Redmond, John A.; Brei, Diann; Luntz, Jonathan; Browne, Alan L.; Johnson, Nancy L.

    2009-03-01

    Shape memory alloy (SMA) actuation is becoming an increasingly viable technology for industrial applications as many of the technical issues that have limited its use are being addressed (speed of actuation, mechanical connections, performance degradation, quality control, etc.) while increasing production capacities drive costs to practical levels. Shape memory alloys are often selected because of their high energy density which can lead to compact actuators; however, wire forms with small cross-sectional diameters tend to be long (10 to 50 times the length of required stroke). Spooling the wire can be used for compact packaging, but as the spool diameter decreases performance losses and fatigue increase due to bending strains and stresses. This paper presents a simple, design-level model for spooled SMA wire actuators with linear motion outputs that includes the effects of friction and wire bending and accounts for the actuator geometry, applied load, and material friction and constitutive properties. The model was validated experimentally with respect to the ratio of mandrel to SMA wire diameter and agrees well in both form and magnitude with experiments. The resulting model provides the framework for the analysis and synthesis of spooled SMA wire actuators to guide the selection of design parameters with respect to the tradeoffs between performance and packaging.

  7. The Wire-Grasping Method as a New Technique for Forceps Biopsy of Biliary Strictures: A Prospective Randomized Controlled Study of Effectiveness.

    PubMed

    Yamashita, Yasunobu; Ueda, Kazuki; Kawaji, Yuki; Tamura, Takashi; Itonaga, Masahiro; Yoshida, Takeichi; Maeda, Hiroki; Magari, Hirohito; Maekita, Takao; Iguchi, Mikitaka; Tamai, Hideyuki; Ichinose, Masao; Kato, Jun

    2016-07-15

    Transpapillary forceps biopsy is an effective diagnostic technique in patients with biliary stricture. This prospective study aimed to determine the usefulness of the wire-grasping method as a new technique for forceps biopsy. Consecutive patients with biliary stricture or irregularities of the bile duct wall were randomly allocated to either the direct or wire-grasping method group. In the wiregrasping method, forceps in the duodenum grasps a guidewire placed into the bile duct beforehand, and then, the forceps are pushed through the papilla without endoscopic sphincterotomy. In the direct method, forceps are directly pushed into the bile duct alongside a guide-wire. The primary endpoint was the success rate of obtaining specimens suitable for adequate pathological examination. In total, 32 patients were enrolled, and 28 (14 in each group) were eligible for analysis. The success rate was significantly higher using the wire-grasping method than the direct method (100% vs 50%, p=0.016). Sensitivity and accuracy for the diagnosis of cancer were comparable in patients with the successful procurement of biopsy specimens between the two methods (91% vs 83% and 93% vs 86%, respectively). The wire-grasping method is useful for diagnosing patients with biliary stricture or irregularities of the bile duct wall.

  8. Application of Ampere’s law to a non-infinite wire and to a moving charge

    NASA Astrophysics Data System (ADS)

    Aledealat, K.; Duston, C. L.

    2018-07-01

    In this work we demonstrate how to apply Ampere’s law to a non-infinite wire that is a part of a complete circuit with a steady current. We show that this can be done by considering the magnetic field from the whole circuit, without having to directly introduce the displacement current. This example can be used to isolate and clarify students’ confusion about the application of Ampere’s law to a short wire. The second part of this work focuses on the application of Ampere’s law to a non-relativistic moving charge. It exposes the students to the Dirac delta function in a physical example and guides them to finding the magnetic field of a moving charge in a reasonable way.

  9. Investigation of Axial Electric Field Measurements with Grounded-Wire TEM Surveys

    NASA Astrophysics Data System (ADS)

    Zhou, Nan-nan; Xue, Guo-qiang; Li, Hai; Hou, Dong-yang

    2018-01-01

    The grounded-wire transient electromagnetic (TEM) surveying is often performed along the equatorial direction with its observation lines paralleling to the transmitting wire with a certain transmitter-receiver distance. However, such method takes into account only the equatorial component of the electromagnetic field, and a little effort has been made on incorporating the other major component along the transmitting wire, here denoted as axial field. To obtain a comprehensive understanding of its fundamental characteristics and guide the designing of the corresponding observation system for reliable anomaly detection, this study for the first time investigates the axial electric field from three crucial aspects, including its decay curve, plane distribution, and anomaly sensitivity, through both synthetic modeling and real application to one major coal field in China. The results demonstrate a higher sensitivity to both high- and low-resistivity anomalies by the electric field in axial direction and confirm its great potentials for robust anomaly detection in the subsurface.

  10. Self-inflicted long complex urethro-vesical foreign body: is open surgery always needed?

    PubMed Central

    Garg, Manish; Kumar, Manoj; Sankhwar, Satyanarayan; Singh, Vishwajeet

    2013-01-01

    In this case report, we describe our experience of a self-inflicted long complex urethrovesical foreign body managed suprapubically through the minimally invasive technique. A 21-year-old man with antipsychotic treatment for the past 10 years presented with a long electric cable wire in his bladder with the distal end in the penile urethra. He presented with symptoms of voiding difficulty and gross haematuria. An attempt of gentle retrieval of wire through the cystoscopic forceps was not successful due to a very complex knot of cable in the bladder. To avoid open surgery such as suprapubic cystotomy, the percutaneous minimally invasive approach was planned. Access to the bladder was achieved by the suprapubic puncture of the bladder, placement of a guide-wire and serial dilation of supra-pubic tract. With the help of nephroscope, through suprapubic tract, the cable wire was retrieved antegradely without causing undue trauma to the bladder or urethra. PMID:23749820

  11. Preliminary experimental study on splenic hemodynamics of radiofrequency ablation for the spleen.

    PubMed

    Baba, Yasutaka; Hayashi, Sadao; Nagasato, Kohei; Higashi, Michiyo; Yoshiura, Takashi

    2017-08-01

    To test the splenic blood flow change after radiofrequency ablation (RFA) of the spleen in a porcine experimental model. Six pigs underwent RFA of the spleen via laparotomy. During the procedure of RFA, clamping of splenic artery (one) and both splenic artery/vein (one) was also performed. Measurement of blood flow of both splenic artery (SA) and splenic vein (SV) with flow-wire at pre- and post-RFA of the spleen was also performed. Ablated splenic lesions were created as estimating ∼50% area of the spleen in all pigs. Resected specimens reveal not only the coagulated necrosis but also the congestion of the spleen. On the SA hemodynamics, maximum peak velocity (MPV) changed from 37 ± 7 to 24 ± 8 cm/s (normal), 11 to 10 cm/s (clamp of the SA), and 12 to 7.5 cm/s (clamp of both SA/SV), respectively. On the SV hemodynamic, MPV changed from 15 ± 5 to 13 ± 4 cm/s (normal), 17 to 15 cm/s (clamp of the SA), and 17 to 26 cm/s (clamp of both SA/SV), respectively. RFA of the spleen could induce coagulation necrosis and reduce the splenic arterial blood flow.

  12. Parallel Radiofrequency Transmission for the Reduction of Heating in Deep Brain Stimulation Leads at 3T

    NASA Astrophysics Data System (ADS)

    McElcheran, Clare

    Deep Brain Stimulation (DBS) is increasingly used to treat a variety of brain diseases by sending electrical impulses to deep brain nuclei through long, electrically conductive leads. Magnetic resonance imaging (MRI) of patients pre- and post-implantation is desirable to target and position the implant, to evaluate possible side-effects and to examine DBS patients who have other health conditions. Although MRI is the preferred modality for pre-operative planning, MRI post-implantation is limited due to the risk of high local power deposition, and therefore tissue heating, at the tip of the lead. The localized power deposition arises from currents induced in the leads caused by coupling with the radiofrequency (RF) transmission field during imaging. In this thesis, parallel RF transmission (pTx) is used to tailor the RF electric field to suppress coupling effects. Three pTx coil configurations with 2-elements, 4-elements, and 8-elements, respectively, were investigated. Optimal input voltages to minimize coupling, while maintaining RF magnetic field homogeneity, were determined using a Nelder-Mead optimization algorithm. Resulting electric and magnetic fields were compared to that of a 16-rung birdcage coil. Experimental validation was performed with a custom-built 4-element pTx coil. Three cases were investigated to develop and evaluate this technique. First, a Proof-of-Concept study was performed to investigate the case of a simple, uniform cylindrical phantom with a straight, perfectly conducting wire. Second, a heterogeneous subject with bilateral, curved implanted wires was investigated. Finally, the third case investigated realistic patient lead-trajectories obtained from intra-operative CT scans. In all three cases, specific absorption rate (SAR), a metric used to quantify power deposition which results in heating, was reduced by over 90%. Maximal reduction in SAR was obtained with the 8-element pTx coil. Magnetic field homogeneity was comparable to the birdcage coil for the 4- and 8-element pTx configurations. Although further research is required before clinical implementation, these initial results suggest that the concept of optimizing pTx to reduce DBS heating effects holds considerable promise.

  13. Activity-based cost analysis of hepatic tumor ablation using CT-guided high-dose rate brachytherapy or CT-guided radiofrequency ablation in hepatocellular carcinoma.

    PubMed

    Schnapauff, D; Collettini, F; Steffen, I; Wieners, G; Hamm, B; Gebauer, B; Maurer, M H

    2016-02-25

    To analyse and compare the costs of hepatic tumor ablation with computed tomography (CT)-guided high-dose rate brachytherapy (CT-HDRBT) and CT-guided radiofrequency ablation (CT-RFA) as two alternative minimally invasive treatment options of hepatocellular carcinoma (HCC). An activity based process model was created determining working steps and required staff of CT-RFA and CT-HDRBT. Prorated costs of equipment use (purchase, depreciation, and maintenance), costs of staff, and expenditure for disposables were identified in a sample of 20 patients (10 treated by CT-RFA and 10 by CT-HDRBT) and compared. A sensitivity and break even analysis was performed to analyse the dependence of costs on the number of patients treated annually with both methods. Costs of CT-RFA were nearly stable with mean overall costs of approximately 1909 €, 1847 €, 1816 € and 1801 € per patient when treating 25, 50, 100 or 200 patients annually, as the main factor influencing the costs of this procedure was the single-use RFA probe. Mean costs of CT-HDRBT decreased significantly per patient ablation with a rising number of patients treated annually, with prorated costs of 3442 €, 1962 €, 1222 € and 852 € when treating 25, 50, 100 or 200 patients, due to low costs of single-use disposables compared to high annual fix-costs which proportionally decreased per patient with a higher number of patients treated annually. A break-even between both methods was reached when treating at least 55 patients annually. Although CT-HDRBT is a more complex procedure with more staff involved, it can be performed at lower costs per patient from the perspective of the medical provider when treating more than 55 patients compared to CT-RFA, mainly due to lower costs for disposables and a decreasing percentage of fixed costs with an increasing number of treatments.

  14. CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma: specific technical aspects and clinical results.

    PubMed

    Sommer, C M; Lemm, G; Hohenstein, E; Bellemann, N; Stampfl, U; Goezen, A S; Rassweiler, J; Kauczor, H U; Radeleff, B A; Pereira, P L

    2013-06-01

    This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. We included 22 consecutive patients (3 women; age 74.2 ± 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 ± 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 ± 13.6 min and 43.7 ± 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 ± 8.8 months, local recurrence-free survival was 14.4 ± 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 ± 16.6 ml/min/1.73 m(2) before RF ablation vs. 47.2 ± 11.9 ml/min/1.73 m(2) after RF ablation; not significant). CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.

  15. Interventional magnetic resonance angiography with no strings attached: wireless active catheter visualization.

    PubMed

    Quick, Harald H; Zenge, Michael O; Kuehl, Hilmar; Kaiser, Gernot; Aker, Stephanie; Massing, Sandra; Bosk, Silke; Ladd, Mark E

    2005-02-01

    Active instrument visualization strategies for interventional MR angiography (MRA) require vascular instruments to be equipped with some type of radiofrequency (RF) coil or dipole RF antenna for MR signal detection. Such visualization strategies traditionally necessitate a connection to the scanner with either coaxial cable or laser fibers. In order to eliminate any wire connection, RF resonators that inductively couple their signal to MR surface coils were implemented into catheters to enable wireless active instrument visualization. Instrument background to contrast-to-noise ratio was systematically investigated as a function of the excitation flip angle. Signal coupling between the catheter RF coil and surface RF coils was evaluated qualitatively and quantitatively as a function of the catheter position and orientation with regard to the static magnetic field B0 and to the surface coils. In vivo evaluation of the instruments was performed in interventional MRA procedures on five pigs under MR guidance. Cartesian and projection reconstruction TrueFISP imaging enabled simultaneous visualization of the instruments and vascular morphology in real time. The implementation of RF resonators enabled robust visualization of the catheter curvature to the very tip. Additionally, the active visualization strategy does not require any wire connection to the scanner and thus does not hamper the interventionalist during the course of an intervention.

  16. Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography.

    PubMed

    Huang, Xingfu; Chen, Yanjia; Huang, Zheng; He, Liwei; Liu, Shenrong; Deng, Xiaojiang; Wang, Yongsheng; Li, Rucheng; Xu, Dingli; Peng, Jian

    2018-06-01

    Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate the efficacy and safety of catheter radiofrequency ablation for arrhythmias under the guidance of a Carto 3 three-dimensional (3D) mapping system in an operating room without DSA. Patients were enrolled according to the type of arrhythmia. The Carto 3 mapping system was used to reconstruct heart models and guide the electrophysiologic examination, mapping, and ablation. The total procedure, reconstruction, electrophysiologic examination, and mapping times were recorded. Furthermore, immediate success rates and complications were also recorded. A total of 20 patients were enrolled, including 12 males. The average age was 51.3 ± 17.2 (19-76) years. Nine cases of atrioventricular nodal re-entrant tachycardia, 7 cases of frequent ventricular premature contractions, 3 cases of Wolff-Parkinson-White syndrome, and 1 case of typical atrial flutter were included. All arrhythmias were successfully ablated. The procedure time was 127.0 ± 21.0 (99-177) minutes, the reconstruction time was 6.5 ± 2.9 (3-14) minutes, the electrophysiologic study time was 10.4 ± 3.4 (6-20) minutes, and the mapping time was 11.7 ± 8.3 (3-36) minutes. No complications occurred. Radiofrequency ablation of arrhythmias without DSA is effective and feasible under the guidance of the Carto 3 mapping system. However, the electrophysiology physician must have sufficient experience, and related emergency measures must be present to ensure safety.

  17. Echo-Planar Imaging-Based, J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    DTIC Science & Technology

    2015-10-01

    cancer is through imaging techniques including ultrasound , computed tomography (CT), and magnetic resonance imaging (MRI) with or without the help...performed at least 8 weeks after transrectal ultrasound -guided sextant biopsy. The entire protocol was ap- proved by the Institutional Review Board...volume of interest (VOI) was localized using three slice-selective radiofrequency (RF) pulses (90°–180°–180°) (Fig. 1). The total time for the

  18. Resonant circuit which provides dual-frequency excitation for rapid cycling of an electromagnet

    DOEpatents

    Praeg, W.F.

    1982-03-09

    Disclosed is a novel ring-magnet control circuit that permits synchrotron repetition rates much higher than the frequency of the sinusoidal guide field of the ring magnet during particle acceleration. The control circuit generates sinusoidal excitation currents of different frequencies in the half waves. During radio-frequency acceleration of the synchrotron, the control circuit operates with a lower frequency sine wave and, thereafter, the electromagnets are reset with a higher-frequency half sine wave.

  19. Ablative therapy for liver tumours

    PubMed Central

    Dick, E A; Taylor-Robinson, S D; Thomas, H C; Gedroyc, W M W

    2002-01-01

    Established ablative therapies for the treatment of primary and secondary liver tumours, including percutaneous ethanol injection, cryotherapy, and radiofrequency ablation, are discussed. Newer techniques such as magnetic resonance imaging guided laser interstitial thermal therapy of liver tumours has produced a median survival rate of 40.8 months after treatment. The merits of this newly emerging technique are discussed, together with future developments, such as focused ultrasound therapy, which holds the promise of non-invasive thermoablation treatment on an outpatient basis. PMID:11950826

  20. A Novel RFID-Based Sensing Method for Low-Cost Bolt Loosening Monitoring.

    PubMed

    Wu, Jian; Cui, Xingmei; Xu, Yunpeng

    2016-01-28

    In coal mines, bolt loosening in the cage guide is affected by the harsh environmental factors and cage hoist vibration, leading to significant threats to work safety. It is crucial, to this effect, to successfully detect the status of multipoint bolts of guide structures. This paper proposes a system to monitor bolt status in harsh environments established based on the RFID technique. A proof-of-concept model was demonstrated consisting of a bolt gearing system, passive UHF RFID tags, a reader, and monitoring software. A tinfoil metal film is fixed on the retaining plate and an RFID tag bonded to a large gear, with the bolt to be detected fixed in the center of a smaller gear. The radio-frequency signal cannot be received by the reader if the tag is completely obscured by the tinfoil, and if the bolt is loose, the tag's antenna is exposed when the gear revolves. A radio-frequency signal that carries corresponding bolt's information is transmitted by the RFID tag to the RFID reader due to coil coupling, identifying loose bolt location and reporting them in the software. Confirmatory test results revealed that the system indeed successfully detects bolt loosening and comparative test results (based on a reed switch multipoint bolt loosening monitor system) provided valuable information regarding the strengths and weaknesses of the proposed system.

  1. A Novel RFID-Based Sensing Method for Low-Cost Bolt Loosening Monitoring

    PubMed Central

    Wu, Jian; Cui, Xingmei; Xu, Yunpeng

    2016-01-01

    In coal mines, bolt loosening in the cage guide is affected by the harsh environmental factors and cage hoist vibration, leading to significant threats to work safety. It is crucial, to this effect, to successfully detect the status of multipoint bolts of guide structures. This paper proposes a system to monitor bolt status in harsh environments established based on the RFID technique. A proof-of-concept model was demonstrated consisting of a bolt gearing system, passive UHF RFID tags, a reader, and monitoring software. A tinfoil metal film is fixed on the retaining plate and an RFID tag bonded to a large gear, with the bolt to be detected fixed in the center of a smaller gear. The radio-frequency signal cannot be received by the reader if the tag is completely obscured by the tinfoil, and if the bolt is loose, the tag’s antenna is exposed when the gear revolves. A radio-frequency signal that carries corresponding bolt’s information is transmitted by the RFID tag to the RFID reader due to coil coupling, identifying loose bolt location and reporting them in the software. Confirmatory test results revealed that the system indeed successfully detects bolt loosening and comparative test results (based on a reed switch multipoint bolt loosening monitor system) provided valuable information regarding the strengths and weaknesses of the proposed system. PMID:26828498

  2. The use of echocardiography in Wolff-Parkinson-White syndrome.

    PubMed

    Cai, Qiangjun; Shuraih, Mossaab; Nagueh, Sherif F

    2012-04-01

    Endocardial mapping and radiofrequency catheter ablation are well established modalities for the diagnosis and treatment of patients with Wolff-Parkinson-White (WPW) syndrome associated with tachyarrhythmias. However, the electrophysiologic techniques are invasive, require radiation exposure, and lack spatial resolution of cardiac structures. A variety of echocardiographic techniques have been investigated as a non-invasive alternative for accessory pathway localization. Conventional M-mode echocardiography can detect the fine premature wall motion abnormalities associated with WPW syndrome. However, it is unable to identify the exact site of accessory pathway with sufficient accuracy. 2D, 2D-guided M-mode, and 2D phase analysis techniques are limited by image quality and endocardial border definition. Various modalities of tissue Doppler echocardiography significantly increase the accuracy of left-sided accessory pathway localization to 80-90% even in patients with poor acoustic window. However, right-sided pathways remain a diagnostic challenge. Strain echocardiography by speckle tracking has recently been evaluated and appears promising. Different cardiac abnormalities have been detected by echocardiography in WPW patients. Patients with WPW syndrome and tachyarrhythmias have impaired systolic and diastolic function which improves after radiofrequency ablation. Echocardiography is useful in identifying patient with accessory pathway-associated left ventricular dyssynchrony and dysfunction who may benefit from ablation therapy. Transesophageal and intracardiac echocardiography have been used to guide ablation procedure. Ablation-related complications detected by routine echocardiography are infrequent, rarely clinically relevant, and of limited value.

  3. 2D projection-based software application for mobile C-arms optimises wire placement in the proximal femur - An experimental study.

    PubMed

    Swartman, B; Frere, D; Wei, W; Schnetzke, M; Beisemann, N; Keil, H; Franke, J; Grützner, P A; Vetter, S Y

    2017-10-01

    A new software application can be used without fixed reference markers or a registration process in wire placement. The aim was to compare placement of Kirschner wires (K-wires) into the proximal femur with the software application versus the conventional method without guiding. As study hypothesis, we assumed less placement attempts, shorter procedure time and shorter fluoroscopy time using the software. The same precision inside a proximal femur bone model using the software application was premised. The software detects a K-wire within the 2D fluoroscopic image. By evaluating its direction and tip location, it superimposes a trajectory on the image, visualizing the intended direction of the K-wire. The K-wire was positioned in 20 artificial bones with the use of software by one surgeon; 20 bones served as conventional controls. A brass thumb tack was placed into the femoral head and its tip targeted with the wire. Number of placement attempts, duration of the procedure, duration of fluoroscopy time and distance to the target in a postoperative 3D scan were recorded. Compared with the conventional method, use of the application showed fewer attempts for optimal wire placement (p=0.026), shorter duration of surgery (p=0.004), shorter fluoroscopy time (p=0.024) and higher precision (p=0.018). Final wire position was achieved in the first attempt in 17 out of 20 cases with the software and in 9 out of 20 cases with the conventional method. The study hypothesis was confirmed. The new application optimised the process of K-wire placement in the proximal femur in an artificial bone model while also improving precision. Benefits lie especially in the reduction of placement attempts and reduction of fluoroscopy time under the aspect of radiation protection. The software runs on a conventional image intensifier and can therefore be easily integrated into the daily surgical routine. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Deformable 3D-2D registration for guiding K-wire placement in pelvic trauma surgery

    NASA Astrophysics Data System (ADS)

    Goerres, J.; Jacobson, M.; Uneri, A.; de Silva, T.; Ketcha, M.; Reaungamornrat, S.; Vogt, S.; Kleinszig, G.; Wolinsky, J.-P.; Osgood, G.; Siewerdsen, J. H.

    2017-03-01

    Pelvic Kirschner wire (K-wire) insertion is a challenging surgical task requiring interpretation of complex 3D anatomical shape from 2D projections (fluoroscopy) and delivery of device trajectories within fairly narrow bone corridors in proximity to adjacent nerves and vessels. Over long trajectories ( 10-25 cm), K-wires tend to curve (deform), making conventional rigid navigation inaccurate at the tip location. A system is presented that provides accurate 3D localization and guidance of rigid or deformable surgical devices ("components" - e.g., K-wires) based on 3D-2D registration. The patient is registered to a preoperative CT image by virtually projecting digitally reconstructed radiographs (DRRs) and matching to two or more intraoperative x-ray projections. The K-wire is localized using an analogous procedure matching DRRs of a deformably parametrized model for the device component (deformable known-component registration, or dKC-Reg). A cadaver study was performed in which a K-wire trajectory was delivered in the pelvis. The system demonstrated target registration error (TRE) of 2.1 ± 0.3 mm in location of the K-wire tip (median ± interquartile range, IQR) and 0.8 ± 1.4º in orientation at the tip (median ± IQR), providing functionality analogous to surgical tracking / navigation using imaging systems already in the surgical arsenal without reliance on a surgical tracker. The method offers quantitative 3D guidance using images (e.g., inlet / outlet views) already acquired in the standard of care, potentially extending the advantages of navigation to broader utilization in trauma surgery to improve surgical precision and safety.

  5. Percutaneous CT-Guided Sympathicolysis with Radiofrequency for the Treatment of Palmar Hyperhidrosis.

    PubMed

    García-Barquín, Paula; Aquerreta Beola, Jesús Dámaso; Bondía Gracía, José María; España Alonso, Agustín; Pérez Cajaraville, Juan; Bartolomé Leal, Pablo; Bastarrika, Gorka

    2017-06-01

    To evaluate the benefits of computed tomography (CT)-guided percutaneous sympathicolysis with radiofrequency in patients with primary palmar hyperhidrosis (PPHH) in terms of safety, patient satisfaction, and short- and long-term efficacy. A total of 139 procedures in 108 patients (mean age, 29.89 y ± 10.94), including 50 men and 58 women, with PPHH and therapy-resistance of nonsurgical treatments were retrospectively analyzed. Treatment was performed bilaterally at T2, T3, and T4 levels, reaching 90°C during 8 minutes. Technical success, immediate efficacy, and presence of complications were analyzed. For follow-up, the Hyperhidrosis Disease Severity Scale was used to evaluate the hyperhidrosis before, at one month, and in the long-term through a survey of 42 patients. Patients' satisfaction and complications were also recorded. The technical success rate was 98.56%. The increase in palmar skin temperature was 4.88°C ± 1.85. A total of 85.3% of participants had completely dry hands immediately after treatment. The mean follow-up time was 41.34 months (range, 6-62 mo). One month after treatment, the response rate was 77.38% (P < .001). At long-term follow-up, the response rate was 69.04% (P < .001). Two major complications were observed (1.8%), 52.38% of patients were satisfied, and 59.52% of patients presented compensatory hyperhidrosis at long-term follow-up. Percutaneous CT-guided sympathicolysis is a safe and effective technique for the treatment of PPHH and can be considered as a second choice in patients in whom other nonsurgical therapeutic options have failed, despite the compensatory hyperhidrosis rates. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  6. Intraoperative Ultrasound for Peripheral Nerve Applications.

    PubMed

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Simple and fast orotracheal intubation procedure in rats.

    PubMed

    Tomasello, Giovanni; Damiani, Francesco; Cassata, Giovanni; Palumbo, Vincenzo Davide; Sinagra, Emanuele; Damiani, Provvidenza; Bruno, Antonino; Cicero, Luca; Cupido, Francesco; Carini, Francesco; Lo Monte, Attilio Ignazio

    2016-05-06

    Endotracheal intubation in the rat is difficult because of the extremely small size of anatomical structures (oral cavity, epiglottis and vocal cords), small inlet for an endotracheal tube and the lack of proper technical instruments. In this study we used seventy rats weighting 400-500 g. The equipment needed for the intubation was an operating table, a longish of cotton, a cotton tip, orotracheal tube, neonatal laryngoscope blades, KTR4 small animal ventilator and isoflurane for inhalation anaesthesia. Premedication was carried out by medetomidine hydrochloride 1 mg/mL; then, thanks to a closed glass chamber, a mixture of oxygen and isoflurane was administered. By means of a neonatal laryngoscope the orotracheal tube was advanced into the oral cavity until the wire guide was visualized trough the vocal cords; then it was passed through them. The tube was introduced directly into the larynx over the wire guide; successively, the guide was removed and the tube placed into the trachea. Breathing was confirmed using a glove, cut at the end of a finger, simulating a small balloon. We achieved a fast and simple orotracheal intubation in all animals employed. We believe that our procedure is easier and faster than those previously reported in scientific literature.

  8. Mechanochemical endovenous ablation versus radiofrequency ablation in the treatment of primary small saphenous vein insufficiency (MESSI trial): study protocol for a randomized controlled trial.

    PubMed

    Boersma, Doeke; van Eekeren, Ramon R J P; Kelder, Hans J C; Werson, Debora A B; Holewijn, Suzanne; Schreve, Michiel A; Reijnen, Michel M P J; de Vries, Jean Paul P M

    2014-10-29

    Minimally invasive endothermal techniques, for example, radiofrequency ablation (RFA), have revolutionized the treatment of insufficient truncal veins and are associated with an excellent outcome. The use of thermal energy requires the instillation of tumescent anesthesia around the vein. Mechanochemical endovenous ablation (MOCA™) combines mechanical endothelial damage, using a rotating wire, with simultaneous infusion of a liquid sclerosans. Tumescent anesthesia is not required as no heat is used. Prospective studies using MOCA™ in both great and small saphenous veins showed good anatomical and clinical results with fast postoperative recovery. The MESSI trial (Mechanochemical Endovenous ablation versus radiofrequency ablation in the treatment of primary Small Saphenous vein Insufficiency) is a multicenter randomized controlled trial in which a total of 160 patients will be randomized (1:1) to MOCA™ or RFA. Consecutive patients with primary small saphenous vein incompetence, who meet the eligibility criteria, will be invited to participate in this trial. The primary endpoint is anatomic success, defined as occlusion of the treated veins objectified with duplex ultrasonography at 1 year follow-up. Secondary endpoints are post-procedural pain, initial technical success, clinical success, complications and the duration of the procedure. Initial technical success is defined as the ability to position the device adequately, treat the veins as planned and occlude the treated vein directly after the procedure has been proven by duplex ultrasonography. Clinical success is defined as an objective improvement of clinical outcome after treatment, measured with the Venous Clinical Severity Score (VCSS). Power analyses are conducted for anatomical success and post-procedural pain.Both groups will be evaluated on an intention-to-treat principle. The hypothesis of the MESSI trial is that the anatomic success rate of MOCA™ is not inferior to RFA. The second hypothesis is that post-procedural pain is significantly less after MOCA compared to RFA. NTR4613 Date of trial registration: 28 May 2014.

  9. Practical aspects of instrumentation system installation, volume 13

    NASA Technical Reports Server (NTRS)

    Borek, R. W.; Pool, A. (Editor); Sanderson, K. C. (Editor)

    1981-01-01

    A review of factors influencing installation of aircraft flight test instrumentation is presented. Requirements, including such factors as environment, reliability, maintainability, and system safety are discussed. The assessment of the mission profile is followed by an overview of electrical and mechanical installation factors with emphasis on shock/vibration isolation systems and standardization of the electric wiring installation, two factors often overlooked by instrumentation engineers. A discussion of installation hardware reviews the performance capabilities of wiring, connectors, fuses and circuit breakers, and a guide to proper selections is provided. The discussion of the installation is primarily concerned with the electrical wire routing, shield terminations and grounding. Also inclued are some examples of installation mistakes that could affect system accuracy. System verification procedures and special considerations such as sneak circuits, pyrotechnics, aircraft antenna patterns, and lightning strikes are discussed.

  10. Percutaneous Ultrasound-Guided TOPAZ Radiofrequency Coblation: A Novel Coaxial Technique for the Treatment of Recalcitrant Plantar Fasciitis-Our Experience.

    PubMed

    Shah, Amit; Best, Alistair J; Rennie, Winston J

    2016-06-01

    Various therapeutic options are available for treatment of recalcitrant plantar fasciitis. Studies using TOPAZ coblation (ArthroCare, Sunnyvale, CA) have had good early results. The current coblation technique involves a surgical incision or breach of the highly specialized plantar fat pad, which can be associated with risks. We describe a novel technique of ultrasound-guided percutaneous coblation with a lateral heel approach. Advantages include precise targeting of the plantar fascia by direct dynamic visualization of the coblation tip, a true percutaneous approach with a needle skin puncture (<5 mm), and preservation of the plantar fat pad by using a lateral heel approach. © 2016 by the American Institute of Ultrasound in Medicine.

  11. Image-Guided Ablation of Adrenal Lesions

    PubMed Central

    Yamakado, Koichiro

    2014-01-01

    Although laparoscopic adrenalectomy has remained the standard of care for the treatment for adrenal tumors, percutaneous image-guided ablation therapy, such as chemical ablation, radiofrequency ablation, cryoablation, and microwave ablation, has been shown to be clinically useful in many nonsurgical candidates. Ablation therapy has been used to treat both functioning adenomas and malignant tumors, including primary adrenal carcinoma and metastasis. For patients with functioning adenomas, biochemical and symptomatic improvement is achieved in 96 to 100% after ablation; for patients with malignant adrenal neoplasms, however, the survival benefit from ablation therapy remains unclear, though good initial results have been reported. This article outlines the current role of ablation therapy for adrenal lesions, as well as identifying some of the technical considerations for this procedure. PMID:25049444

  12. Dynamics of alkali ions-neutral molecules reactions: Radio frequency-guided beam experimental cross-sections and direct quasiclassical trajectory studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aguilar, J.; Andres, J. de; Lucas, J. M.

    2012-11-27

    Different reactive processes taking place in collisions between alkali ions and neutral i-C{sub 3}H{sub 7}Cl molecules in the low (center of mass frame) energy range have been studied using an octopole radiofrequency guided-ion-beam apparatus developed in our laboratory. Cross-section energy dependences for all these reactions have been obtained in absolute units. Ab initio electronic structure calculations for those colliding systems evolving on the ground single potential surface have given relevant information on the main topological features of the surfaces. For some of the reactions a dynamic study by 'on the fly' trajectories has complemented the available experimental and electronic structuremore » information.« less

  13. Material Selection for Cable Gland to Improved Reliability of the High-hazard Industries

    NASA Astrophysics Data System (ADS)

    Vashchuk, S. P.; Slobodyan, S. M.; Deeva, V. S.; Vashchuk, D. S.

    2018-01-01

    The sealed cable glands (SCG) are available to ensure safest connection sheathed single wire for the hazard production facility (nuclear power plant and others) the same as pilot cable, control cables, radio-frequency cables et al. In this paper, we investigate the specifics of the material selection of SCG with the express aim of hazardous man-made facility. We discuss the safe working conditions for cable glands. The research indicates the sintering powdered metals cables provide the reliability growth due to their properties. A number of studies have demonstrated the verification of material selection. On the face of it, we make findings indicating that double glazed sealed units could enhance reliability. We had evaluated sample reliability under fire conditions, seismic load, and pressure containment failure. We used the samples mineral insulated thermocouple cable.

  14. Melt growth of zinc aluminate spinel single crystal by the micro-pulling down method under atmospheric pressure

    NASA Astrophysics Data System (ADS)

    Kamada, K.; Shoji, Y.; Yamaji, A.; Kurosawa, S.; Yokota, Yuui; Ohashi, Y.; Kim, Kyoung Jin; Ivanov, M.; Kochurikhin, V. V.; Yoshikawa, A.

    2018-06-01

    ZnAl2O4 crystals were grown using few starting compositions with various ZnO:AlO3/2 ratio using an Ir wire seed and Ir + Re crucible under ordinary pressure with Ar + 2%O2 atmosphere by the radiofrequency heating μ-PD furnace. The ZnAl2O4 spinel single crystal with 4 mm diameter could be successfully grown by the μ-PD method by optimization of starting melt composition considering with Zinc oxide evaporation. During 10 min of growth under normal pressure the formation of ZnAl2O4 single phase observed even at high vapor pressure of ZnO. The transmittance spectra and X-ray locking curve were measured for evaluating of grown ZnAl2O4 crystals quality.

  15. Caudal Zona Incerta/VOP Radiofrequency Lesioning Guided by Combined Stereotactic MRI and Microelectrode Recording for Posttraumatic Midbrain Resting-Kinetic Tremor.

    PubMed

    Contreras Lopez, William Omar; Azevedo, Angelo R; Cury, Rubens G; Alencar, Francisco; Neville, Iuri S; Reis, Paul R; Navarro, Jessie; Monaco, Bernardo; da Silva, Fabio E Fernandes; Teixeira, Manoel J; Fonoff, Erich T

    2016-02-01

    Reporting the outcome of two patients who underwent unilateral ablative stereotactic surgery to treat pharmacologic resistant posttraumatic tremor (PTT). We present two patients (31 and 47 years old) with refractory PTT severely affecting their quality of life. Under stereotactic guidance, refined by T2-weighted magnetic resonance imaging and double-channel multiunit microelectrode recording (MER), three sequential radiofrequency lesions were performed in the caudal zona incerta (cZi) up to the base of thalamus (VOP). Effects of cZi/VOP lesion were prospectively rated with a tremor rating scale. Both patients demonstrated intraoperative tremor suppression with sustained results up to 18 months follow-up, with improvement of 92% and 84%, respectively, on the tremor rating scale. Tremor improvement was associated with enhancement functionality and quality of life for the patients. The patients returned to their work after the procedure. No adverse effects were observed up to the last follow-up. Radiofrequency lesion of the cZi/VOP target was effective for posttraumatic tremor in both cases. The use of T2-weighted images and MER was found helpful in increasing the precision and safety of the procedure, because it leads the RF probe by relying on neighbor structures based on thalamus and subthalamic nucleus. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Effect of the transverse nonuniformity of the radiofrequency field on the start current and efficiency of gyrodevices with confocal mirrors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nusinovich, Gregory S.; Chainani, Samir; Granatstein, Victor L.

    The theory is developed for analyzing the effect of transverse nonuniformity of the radiofrequency (rf) field on the starting conditions and efficiency of such gyrotron oscillators as gyromonotrons and gyro-backward-wave oscillators (gyro-BWO). The formalism allows one to study this effect in oscillators operating in the regimes of soft and hard self-excitation. Results obtained for a device with a confocal waveguide (or resonator) are compared with the results for conventional gyrodevices where the rf field acting on electrons with different guiding centers is the same. It is shown how to use results of the classical small-signal theory of backward-wave oscillators drivenmore » by linear electron beams for calculating the start currents in gyro-BWOs. The effect of the wave attenuation in waveguide walls on the start current is analyzed, which is important for the design of frequency-tunable gyro-backward-wave oscillators in the THz (and sub THz) frequency range.« less

  17. Possible role for cryoballoon ablation of right atrial appendage tachycardia when conventional ablation fails.

    PubMed

    Amasyali, Basri; Kilic, Ayhan

    2015-06-01

    Focal atrial tachycardia arising from the right atrial appendage usually responds well to radiofrequency ablation; however, successful ablation in this anatomic region can be challenging. Surgical excision of the right atrial appendage has sometimes been necessary to eliminate the tachycardia and prevent or reverse the resultant cardiomyopathy. We report the case of a 48-year-old man who had right atrial appendage tachycardia resistant to multiple attempts at ablation with use of conventional radiofrequency energy guided by means of a 3-dimensional mapping system. The condition led to cardiomyopathy in 3 months. The arrhythmia was successfully ablated with use of a 28-mm cryoballoon catheter that had originally been developed for catheter ablation of paroxysmal atrial fibrillation. To our knowledge, this is the first report of cryoballoon ablation without isolation of the right atrial appendage. It might also be an alternative to epicardial ablation or surgery when refractory atrial tachycardia originates from the right atrial appendage.

  18. Radiofrequency Ablation Followed by Percutaneous Ethanol Ablation Leading to Long-Term Remission of Hyperparathyroidism

    PubMed Central

    Menon, Arun S.; Nazar, P. K.; Moorthy, Srikanth; Kumar, Harish; Nair, Vasantha; Pavithran, Praveen Valiyaparambil; Bhavani, Nisha; Menon, Vadayath Usha; Abraham, Nithya; Jayakumar, R. Vasukutty

    2017-01-01

    A 30-year-old male with cerebral palsy and motor impairment presented with right femur fracture. He had gradually worsening mobility and contractures of all extremities for the preceding 5 years. Evaluation showed multiple vertebral and femoral fractures, severe osteoporosis, a large parathyroid adenoma, and parathormone (PTH) exceeding 2500 pg/mL. Because of poor general health and high anesthetic risk, parathyroidectomy was deemed impractical. Ultrasound-guided radiofrequency ablation (RFA) helped achieve 50% size reduction and PTH levels with better control of hypercalcemia. Later, as calcium and PTH remained elevated, percutaneous ethanol ablation was performed with resultant normalization of PTH and substantial symptomatic improvement. Two years later, he still remains normocalcaemic with normal PTH levels. We propose that RFA and percutaneous ethanol ablation be considered as effective short-term options for surgically difficult cases, which could even help achieve long-term remission. Although not previously reported, our case illustrates that both RFA and percutaneous ethanol ablation could be safely performed successively achieving long-term remission. PMID:29264521

  19. [Transcatheter closure of atrial septal defects in 40 pediatric patients].

    PubMed

    Deng, Dong-an; Zhu, Xian-yang; Hou, Chuan-ju; Han, Xiu-min; Wang, Qi-guang; Jin, Yan; Quan, Wei; Liu, Yang; Wang, Shu-fan

    2003-07-01

    To evaluate the clinical efficiency of transcatheter closure of atrial septal defect (ASD) with AGA-Amplatzer occlusion device in pediatric patients. Forty patients with ASD, 16 males, 24 females, at a mean age of 10.2 years (ranged from 3 to 15 years of age) and with a mean weight of 35.8 kg (ranged from 11 to 87 kg) were studied. Six cases were complicated with pulmonary stenosis (PS), 1 was complicated with ventricular tachycardia (VT). Right heart catheterizations were done in 40 patients for measuring the pressures of right ventricle and pulmonary artery. The balloon diameter of ASD was measured using balloon catheter with guiding wire. The diameter of ASD was measured by TTE and/or TEE, ascertaining the location and size of ASD. Amplatzer occlusion device was sized to be equal to or 1 - 2 mm more than the diameter of balloon stretched. All patients had successful implantation of the Amplatzer device. The success rate was 100%. The diameter measured by TTE was 7 - 30 mm (mean 17.12 mm). The diameter measured by TEE was 7 - 32 mm (mean 18.44 mm). The diameter of balloon stretched of ASD was 8 - 34 mm. Of the 40 cases, 6 were complicated with PS and accepted percutaneous balloon valvuloplasty (PBPV). One case was complicated with VT and accepted radiofrequency catheter ablation (RFCA). Neither complication nor residual shunt was found in any of the patients. The patients were recovered and followed up for 3 or 4 days after deployment of the Amplatzer device. Clinical symptom, cardiac murmur, and findings in ECG, echocardiography and X-ray were improved markedly. AGA-Amplatzer occlusion device is safe and efficient in pediatric patients with ASD.

  20. New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juszkat, Robert, E-mail: radiologiamim@wp.pl; Kulesza, Jerzy; Zarzecka, Anna

    2011-02-15

    To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a-the segment distally the origin of the left CCA,more » halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.« less

  1. Characterization and application of Shape Memory Alloy wires for micro and meso positioning systems

    NASA Astrophysics Data System (ADS)

    Khan, Afzal

    The properties of Shape Memory Alloy (SMA) wires are determined by experimentation, and previously used experimental equipment contributes to measurement errors in data. In this study, various characterization experiments are designed and carried out using a precision characterization instrument for shape memory alloy wires to determine the properties and parameters of the alloy. These experiments demonstrate the behavior of SMA wires under different thermal and loading conditions as they occur in actuation applications. As SMA wires go through phase transformation, a significant amount of contraction force is produced. This actuation force has been used in bias spring actuators and differential actuators. In this dissertation, the force generated during the twinning of martensite is used to actuate positioning systems with small displacements at the micrometer level. A micropositioning system is designed and tested that has a positioning accuracy of about +/-0.15 mum. A relation between the current input and the displacement output is determined for the specific preload. The transformation force generated during the phase change from martensite to austenite is used as an actuation force for a second positioning system that uses linear bearing with a displacement range of about a millimeter. This positioning system actuated with a single nitinol wire and guided by symmetric parallel diaphragm flexures, was designed and tested. The actuation is repeatable to about +/-15 mum with variation of about +/-5 mum in postion at steady temperature.

  2. Patient-specific core decompression surgery for early-stage ischemic necrosis of the femoral head

    PubMed Central

    Wang, Wei; Hu, Wei; Yang, Pei; Dang, Xiao Qian; Li, Xiao Hui; Wang, Kun Zheng

    2017-01-01

    Introduction Core decompression is an efficient treatment for early stage ischemic necrosis of the femoral head. In conventional procedures, the pre-operative X-ray only shows one plane of the ischemic area, which often results in inaccurate drilling. This paper introduces a new method that uses computer-assisted technology and rapid prototyping to enhance drilling accuracy during core decompression surgeries and presents a validation study of cadaveric tests. Methods Twelve cadaveric human femurs were used to simulate early-stage ischemic necrosis. The core decompression target at the anterolateral femoral head was simulated using an embedded glass ball (target). Three positioning Kirschner wires were drilled into the top and bottom of the large rotor. The specimen was then subjected to computed tomography (CT). A CT image of the specimen was imported into the Mimics software to construct a three-dimensional model including the target. The best core decompression channel was then designed using the 3D model. A navigational template for the specimen was designed using the Pro/E software and manufactured by rapid prototyping technology to guide the drilling channel. The specimen-specific navigation template was installed on the specimen using positioning Kirschner wires. Drilling was performed using a guide needle through the guiding hole on the templates. The distance between the end point of the guide needle and the target was measured to validate the patient-specific surgical accuracy. Results The average distance between the tip of the guide needle drilled through the guiding template and the target was 1.92±0.071 mm. Conclusions Core decompression using a computer-rapid prototyping template is a reliable and accurate technique that could provide a new method of precision decompression for early-stage ischemic necrosis. PMID:28464029

  3. Patient-specific core decompression surgery for early-stage ischemic necrosis of the femoral head.

    PubMed

    Wang, Wei; Hu, Wei; Yang, Pei; Dang, Xiao Qian; Li, Xiao Hui; Wang, Kun Zheng

    2017-01-01

    Core decompression is an efficient treatment for early stage ischemic necrosis of the femoral head. In conventional procedures, the pre-operative X-ray only shows one plane of the ischemic area, which often results in inaccurate drilling. This paper introduces a new method that uses computer-assisted technology and rapid prototyping to enhance drilling accuracy during core decompression surgeries and presents a validation study of cadaveric tests. Twelve cadaveric human femurs were used to simulate early-stage ischemic necrosis. The core decompression target at the anterolateral femoral head was simulated using an embedded glass ball (target). Three positioning Kirschner wires were drilled into the top and bottom of the large rotor. The specimen was then subjected to computed tomography (CT). A CT image of the specimen was imported into the Mimics software to construct a three-dimensional model including the target. The best core decompression channel was then designed using the 3D model. A navigational template for the specimen was designed using the Pro/E software and manufactured by rapid prototyping technology to guide the drilling channel. The specimen-specific navigation template was installed on the specimen using positioning Kirschner wires. Drilling was performed using a guide needle through the guiding hole on the templates. The distance between the end point of the guide needle and the target was measured to validate the patient-specific surgical accuracy. The average distance between the tip of the guide needle drilled through the guiding template and the target was 1.92±0.071 mm. Core decompression using a computer-rapid prototyping template is a reliable and accurate technique that could provide a new method of precision decompression for early-stage ischemic necrosis.

  4. Novel devices and systems for terahertz spectroscopy and imaging

    NASA Astrophysics Data System (ADS)

    Wang, Kanglin

    This doctoral thesis documents my research on novel devices and systems for terahertz (THz) spectroscopy and imaging. The research is particularly focused on the manipulation of THz radiation, including subwavelength concentration and low-loss wave guiding. One of the major obstacles for THz imaging is the poor spatial resolution due to the diffraction of the long-wavelength light source. To break this restriction, we build a THz near-field microscopy system by combining apertureless near-field scanning optical microscopy (ANSOM) with terahertz time-domain spectroscopy (THz-TDS). The experimental result indicates a sub-wavelength spatial resolution of about 10 micron. Abnormal frequency response of the ANSOM probe tip is observed, and a dipole antenna model is developed to explain the bandwidth reduction of the detected THz pulses. We also observe and characterize the THz wave propagation on the near-field probe in ANSOM. These studies not only demonstrate the feasibility of ANSOM in the THz frequency range, but also provide fundamental insights into the near-field microscopy in general, such as the broadband compatibility, the propagation effects and the antenna effects. Motivated by our study of the propagation effects in THz ANSOM, we characterize the guided mode of THz pulses on a bare metal wire by directly measuring the spatial profile of electric field of the mode, and find that the wire structure can be used to guide THz waves with outstanding performance. This new broadband THz waveguide exhibits very small dispersion, extremely low attenuation and remarkable structural simplicity. These features make it especially suitable for use in THz sensing and imaging systems. The first THz endoscope is demonstrated based on metal wire waveguides. To improve the input coupling efficiency of such waveguides, we develop a photoconductive antenna with radial symmetry which can generate radially polarized THz radiation matching the waveguide mode. Through THz-TDS measurements and theoretical calculations, we study the dispersion relation of the surface waves on metal wires, which indicates the increasing importance of skin effects for surface waves in the THz frequency range.

  5. A comparison study of different RF shields for an 8-element transceive small animal array at 9.4T.

    PubMed

    Jin, Jin; Li, Yu; Liu, Feng; Weber, Ewald; Crozier, Stuart

    2011-01-01

    In this study, three types of radio-frequency shields are studied and compared in the context of ultra-high field small-animal magnetic resonance imaging. It has been demonstrated that the coil penetration depth and mutual coupling between the coils depend heavily on the type of shield employed. The results were used to guide the design of a 9.4T 8-element transceive small animal array, which provides high overall coil penetration.

  6. Safety in the Chemical Laboratory

    ERIC Educational Resources Information Center

    Steere, Norman V.

    1969-01-01

    Presents the Safety Guide used in the Research Center at Monsanto Chemical Company (St. Louis). Topics include: general safety practices, safety glasses and shoes, respiratory protection, electrical wiring, solvent handling and waste disposal. Procedures are given for evacuating, "tagging out, and "locking out. Special mention is given to…

  7. Electronics Book III.

    ERIC Educational Resources Information Center

    Johnson, Dennis; And Others

    This manual, the third of three curriculum guides for an electronics course, is intended for use in a program combining vocational English as a second language (VESL) with bilingual vocational education. Ten units cover AC fundamentals, circuit protection devices, low voltage circuits, communication systems, graphic illustrations, house wiring,…

  8. Prospective comparison of two management strategies of central venous catheters in burn patients.

    PubMed

    Kealey, G P; Chang, P; Heinle, J; Rosenquist, M D; Lewis, R W

    1995-03-01

    Central venous catheters (CVCs) are associated with sepsis in burn patients. This study was undertaken to compare two strategies of CVC management in patients with major burn injuries. Forty-two burn patients with major burn injuries were randomly assigned to undergo site change every 48 hours of the CVC or to undergo wire guide exchange of the CVC every 48 hours at the same site. Catheter insertion site, distance from the burn wound, cultures of catheter tips, and blood cultures were obtained from all patients in a prospective manner. There was no difference in the incidence of CVC sepsis between the two groups studied. CVCs inserted less than 5 cm from the burn wound developed bacterial contamination at an earlier time than CVCs inserted more than 5 cm from the burn wound. There was no advantage to changing the CVC insertion site every 48 hours. Changing the CVC using the wire guide technique did not prevent, nor predict, CVC bacterial contamination.

  9. A 3D virtual reality simulator for training of minimally invasive surgery.

    PubMed

    Mi, Shao-Hua; Hou, Zeng-Gunag; Yang, Fan; Xie, Xiao-Liang; Bian, Gui-Bin

    2014-01-01

    For the last decade, remarkable progress has been made in the field of cardiovascular disease treatment. However, these complex medical procedures require a combination of rich experience and technical skills. In this paper, a 3D virtual reality simulator for core skills training in minimally invasive surgery is presented. The system can generate realistic 3D vascular models segmented from patient datasets, including a beating heart, and provide a real-time computation of force and force feedback module for surgical simulation. Instruments, such as a catheter or guide wire, are represented by a multi-body mass-spring model. In addition, a realistic user interface with multiple windows and real-time 3D views are developed. Moreover, the simulator is also provided with a human-machine interaction module that gives doctors the sense of touch during the surgery training, enables them to control the motion of a virtual catheter/guide wire inside a complex vascular model. Experimental results show that the simulator is suitable for minimally invasive surgery training.

  10. Ultrasound-guided Radiofrequency Lesioning of the Articular Branches of the Femoral Nerve for the Treatment of Chronic Post-arthroplasty Hip Pain.

    PubMed

    Kim, David J; Shen, Shiqian; Hanna, George M

    2017-02-01

    Total hip arthroplasty (THA) is a common surgical treatment for several conditions of the hip. While the majority of patients obtain satisfactory results, many develop chronic post-arthroplasty hip pain that can be difficult to treat. We evaluate the effectiveness of cooled (60°C) radiofrequency lesioning of the articular branches of the femoral nerve (ABFN) as a minimally invasive treatment for patients suffering from chronic post-arthroplasty hip pain. This treatment has never been described previously in this population. Case report. Center for Pain Medicine, Massachusetts General Hospital, Harvard Medical School. A 59-year-old woman with long-standing osteoarthritis of the right hip who underwent primary total hip arthroplasty and presented with chronic post-arthroplasty hip pain Intervention: Cooled (60°C) radiofrequency lesioning of the ABFN under ultrasound guidance Outcome Measure: Functional ability and numeric rating scale (NRS) scores at rest and with activity. Prior to intervention, the patient reported severe disruption in daily activities, sleep, and relationships; NRS scores at rest and with activity were 4/10 and 10/10, respectively. At 4 weeks following intervention, the patient reported significant improvement in functional ability and NRS scores decreased to 1/10 and 2/10, respectively. At 6 months, the patient's NRS scores at rest and with activity were 0/10 and 1/10, respectively. At 24-month follow-up, the patient continued to endorse significant pain relief with NRS scores at rest and with activity of 0 - 1/10 and 1 - 2/10, respectively. There were no side effects or complications including motor weakness, sensory loss, and neuralgias. Although the patient obtained good results from the intervention, the description of the study is from a single case report. Further study is necessary to investigate the widespread use of this technique and its outcomes. Cooled (60°C) radiofrequency lesioning of the ABFN under ultrasound guidance is both an effective and minimally invasive intervention for chronic post-arthroplasty hip pain. Key words: Radiofrequency lesioning, articular branches, femoral nerve, post-arthoplasty, total hip arthoplasty, hip pain, chronic pain.

  11. Percutaneous Image-guided Radiofrequency Ablation of Tumors in Inoperable Patients - Immediate Complications and Overall Safety.

    PubMed

    Sahay, Anubha; Sahay, Nishant; Kapoor, Ashok; Kapoor, Jyoti; Chatterjee, Abhishek

    2016-01-01

    Percutaneous destruction of cancer cells using a radiofrequency energy source has become an accepted part of the modern armamentarium for managing malignancies. Radiofrequency ablation (RFA) is a relatively novel procedure for treating recurrent and metastatic tumors. It is used for debulking tumors and as adjuvant therapy for palliative care apart from its role as a pain management tool. Its use in the third world countries is limited by various factors such as cost and expertise. In the remotest parts of India, where economic development has been slow, abject poverty with poor health care facilities advanced malignancies present a challenge to health care providers. We undertook this study to assess the safety of the percutaneous RFA tumor ablation as a therapeutic or palliative measure in patients where surgery was not possible. We observed that RFA may be an effective, alternative therapeutic modality for some inoperable tumors where other therapeutic modalities cannot be considered. Palliative and therapeutic image-guided RFAs of tumors may be the only treatment option in patients who are inoperable for a variety of reasons. To assess the safety and complications of RFA in such a patient population is important before embarking upon any interventions given their physically, mentally, and socially compromised status in a country such as India. To assess the safety of percutaneous image-guided radiofrequency tumor ablation and to note the various immediate and early complications of the intervention. This was a prospective, observational study conducted in Tata Main Hospital, Jamshedpur, Jharkhand, India. After approval by the Hospital Approval Committee all patients who consented for percutaneous RFA of their tumor admitted in the hospital were included after taking fully informed consent from patient/close relative keeping the following criteria in view. Patients who were likely to derive a direct benefit in the survival or as a palliative measure for relief in their symptoms and patients who were inoperable because of any of the following reasons: (1) Exhausted conventional treatment options, (2) technical and anatomical contraindications to conventional treatment, (3) medical comorbidities precluding surgery, (4) patient refusal, (5) recurrent tumors, and (6) advanced tumor stage. Conventional Treatment has been defined as surgical resection, radiotherapy, and/or chemotherapy, although the patient eligibility for each treatment may vary. Patients with the following were excluded: (1) Severe coagulopathy, (2) heart, renal, or liver failure, (3) lesions within 1 cm of gall bladder, hilum, bowel wall, and major blood vessels, (4) patient with any metal implant, (5) patients in sepsis, and (6) tumor adjacent to structures at risk (main bile ducts, pericardium, stomach, or bowel). The duration of procedure as well as ablation of tumor free margin was significantly related to the size of the tumor. As the size of tumor increased, duration of procedure increased significantly. A good tumor-free margin also needs to be ablated for optimum results as it prevents residual tumors and recurrences in the future. We observed that tumors sized <3.1 cm were optimal in this regard. Most common adverse event in postprocedure period was pain in and around ablation site. Post-RFA syndrome is also a common and benign self-limiting side effect. Patient counseling and proper selection of patients in the early stages of malignancy can enhance the efficacy of the procedure and patient satisfaction. Percutaneous image-guided RFA is an option in patients where most other tumor management modalities have been exhausted or rejected. RFA may not be free from side effects such as postablation syndrome, pain, and there may be other serious complications such as bleeding, but based on our observations, percutaneous image-guided RFA of tumors is a safe palliative and therapeutic treatment option.

  12. [Percutaneous tracheotomy].

    PubMed

    Paleczny, J; Maciejewski, D; Łoniewska-Paleczny, E; Sawczuk, M; Kaczur, A

    2000-01-01

    The purpose of this study was to compare on the basis of up to date papers currently applied methods of the percutaneous tracheostomy (PT). There are four main PT methods by: Ciaglia, Schachner, Griggs and Fantoni. In these methods a wire is introduced into the trachea serving as a guide for special forceps or series of dilatators of increasing diameter to dilate the wall and allow cannulation of the trachea. In the literature authors found a low incidence of complications after PT. Acute complications were documented in 6-18% and late complications in 1-3% of the patients. Follow-up showed no late obstructive complications at the level of stomia and very low (0.3-0.36%) mortality risk. Translaryngeal tracheostomy (TLT) by Fantoni ensures minimal risk of complications and tissue trauma. In the TLT method through a needle inserted in to the trachea a guide wire is retrogradely pushed out of the mouth and attached to special flexible tracheostomy tube by flexible plastic cone with pointed metal tip. This device is then pulled back through larynx and outwards across the trachea and neck wall by traction on the wire. TLT can also be used in infants and children and in difficult patients in whom other techniques are riskier Review of the literature suggests that the PT can be safe and also cost-effective for properly selected patients in intensive care and other hospital units.

  13. Transfissural Route Used for Preoperative Localization of Small Pulmonary Lesions with a Short Hook Wire and Suture System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iguchi, Toshihiro, E-mail: iguchi@ba2.so-net.ne.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp

    2015-02-15

    PurposeWe retrospectively evaluated the results of the transfissural route for preoperative localization with a short hook wire and suture system for video-assisted thoracoscopic surgery (VATS).MethodsEleven patients with 11 tumors underwent CT-guided transfissural placement of a hook wire before VATS. This route was selected for all patients, because the distance between the tumor and interlobar fissure was much shorter than the required distance traversed using the conventional approach. Complications were evaluated using the National Cancer Institute Common Terminology Criteria for Adverse Events Version 4.0.ResultsThe hook wire was successfully placed using the transfissural route in all but one case. Of these tenmore » successful placements, two tumors needed a second puncture for optimal placement, because the CT scan showed that the first hook wire was not properly placed in the lung. In one patient, we did not attempt replacement after the first placement was incorrect. In ten successful procedures, the mean distance traversed in the parenchyma of the unaffected lung lobe was 27.9 mm. The distance between the pleura and placed hook wire was significantly shorter than the estimated distance between the pleura and hook wire using the conventional route (mean 16.3 vs. 40.9 mm; P = 0.0002). Grade 1 adverse events occurred (11 pneumothoraxes and 4 pulmonary hemorrhages). No grade 2 or higher adverse event was observed.ConclusionsThe transfissural route used for preoperative localization before VATS is useful for selected patients because this route may allow for more limited lung parenchyma resection.« less

  14. Minimally Invasive Calcaneal Displacement Osteotomy Site Using a Reference Kirschner Wire: A Technique Tip.

    PubMed

    Lee, Moses; Guyton, Gregory P; Zahoor, Talal; Schon, Lew C

    2016-01-01

    As a standard open approach, the lateral oblique incision has been widely used for calcaneal displacement osteotomy. However, just as with other orthopedic procedures that use an open approach, complications, including wound healing problems and neurovascular injury in the heel, have been reported. To help avoid these limitations, a percutaneous technique using a Shannon burr for calcaneal displacement osteotomy was introduced. However, relying on a free-hand technique without direct visualization at the osteotomy site has been a major obstacle for this technique. To address this problem, we developed a technical tip using a reference Kirschner wire. A reference Kirschner wire technique provides a reliable and accurate guide for minimally invasive calcaneal displacement osteotomy. Also, the technique should be easy to learn for surgeons new to the procedure. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. An Administrator's Guide to Installing a Telephone System.

    ERIC Educational Resources Information Center

    Forbes, Phyllis Rossiter

    1986-01-01

    Guidelines for administrators concerning installation of a new campus telephone system address these issues: where to start; location and emergency power; the project team; paperwork; communication among those involved in installation; working with the local operating company; existing wiring; the external cable plant; special needs; and training…

  16. A Principal's Guide to ILS Facilities Installation.

    ERIC Educational Resources Information Center

    Ross, Tweed W.

    1992-01-01

    Outlines five facilities considerations that school principals need to address prior to the installation of an integrated learning system (ILS): (1) placement, i.e., labs or classrooms; (2) wiring; (3) environment, including furniture and noise; (4) security, including fire, theft, vandalism, and misuse; and (5) usability, including afterschool…

  17. Workflow oriented software support for image guided radiofrequency ablation of focal liver malignancies

    NASA Astrophysics Data System (ADS)

    Weihusen, Andreas; Ritter, Felix; Kröger, Tim; Preusser, Tobias; Zidowitz, Stephan; Peitgen, Heinz-Otto

    2007-03-01

    Image guided radiofrequency (RF) ablation has taken a significant part in the clinical routine as a minimally invasive method for the treatment of focal liver malignancies. Medical imaging is used in all parts of the clinical workflow of an RF ablation, incorporating treatment planning, interventional targeting and result assessment. This paper describes a software application, which has been designed to support the RF ablation workflow under consideration of the requirements of clinical routine, such as easy user interaction and a high degree of robust and fast automatic procedures, in order to keep the physician from spending too much time at the computer. The application therefore provides a collection of specialized image processing and visualization methods for treatment planning and result assessment. The algorithms are adapted to CT as well as to MR imaging. The planning support contains semi-automatic methods for the segmentation of liver tumors and the surrounding vascular system as well as an interactive virtual positioning of RF applicators and a concluding numerical estimation of the achievable heat distribution. The assessment of the ablation result is supported by the segmentation of the coagulative necrosis and an interactive registration of pre- and post-interventional image data for the comparison of tumor and necrosis segmentation masks. An automatic quantification of surface distances is performed to verify the embedding of the tumor area into the thermal lesion area. The visualization methods support representations in the commonly used orthogonal 2D view as well as in 3D scenes.

  18. Interventional Pain Management for Sacroiliac Tumors in the Oncologic Population: A Case Series and Paradigm Approach.

    PubMed

    Hutson, Nathan; Hung, Joseph C; Puttanniah, Vinay; Lis, Eric; Laufer, Ilya; Gulati, Amitabh

    2017-05-01

    Tumors invading the sacrum and/or ilium often represent incurable metastatic disease, and treatment is targeted toward palliation of symptoms and control of pain. As systemic opioid therapy is frequently inadequate and limited by side effects, a variety of interventional techniques are available to better optimize analgesia. Using six patients as a paradigm for interventional approaches to pain relief, we present a therapeutic algorithm for treating sacroiliac tumor-related pain in the oncologic population. We describe the use of ultrasound-guided proximal sacroiliac joint corticosteroid injection, sacroiliac lateral branch radiofrequency ablation, percutaneous sacroplasty, and implantable neuraxial drug delivery devices to treat malignant sacroiliac pain in six patients. Pre- and postprocedure numerical rating scale (NRS) pain scores, duration of pain relief, and postprocedure pain medication requirements were studied for each patient. Each patient had marked improvement in their pain based on an average postprocedure NRS difference of six points. The average duration of pain relief was eight months. In all cases, opioid requirements decreased after the intervention. Depending on tumor location, burden of disease, and patient preference, patients suffering from metastatic disease to the sacrum may find benefit from use of ultrasound-guided proximal sacroiliac joint corticosteroid injection, sacroiliac lateral branch radiofrequency ablation, percutaneous sacroplasty, dorsal column stimulator leads, and/or implantable neuraxial drug delivery devices. We provide a paradigm for treatment in this patient population. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  19. The advent of ultrasound-guided ablation techniques in nodular thyroid disease: towards a patient-tailored approach.

    PubMed

    Papini, Enrico; Pacella, Claudio M; Misischi, Irene; Guglielmi, Rinaldo; Bizzarri, Giancarlo; Døssing, Helle; Hegedus, Laszlo

    2014-08-01

    Surgery is the long-established therapeutic option for benign thyroid nodules, which steadily grow and become symptomatic. The cost of thyroid surgery, the risk of temporary or permanent complications, and the effect on quality of life, however, remain relevant concerns. Therefore, various minimally invasive treatments, directed towards office-based management of symptomatic nodules, without requiring general anaesthesia, and with negligible damage to the skin and cervical tissues, have been proposed during the past two decades. Today, ultrasound-guided percutaneous ethanol injection and thermal ablation with laser or radiofrequency have been thoroughly evaluated, and are accessible procedures in specialized centres. In clinical practice, relapsing thyroid cysts are effectively managed with percutaneous ethanol injection treatment, which should be considered therapy of choice. In solid non-functioning thyroid nodules that grow or become symptomatic, trained operators may safely induce, with a single session of laser ablation treatment or radiofrequency ablation, a 50% volume decrease and, in parallel, improve local symptoms. In contrast, hyperfunctioning nodules remain best treated with radioactive iodine, which results in a better control of hyperthyroidism, also in the long-term, and fewer side-effects. Currently, minimally invasive treatment is also investigated for achieving local control of small size neck recurrences of papillary thyroid carcinoma in patients who are poor candidates for repeat cervical lymph node dissection. This particular use should still be considered experimental. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Renal sympathetic denervation using an externally irrigated radiofrequency ablation catheter for treatment of resistant hypertension - Acute safety and short term efficacy.

    PubMed

    Yalagudri, Sachin; Raju, Narayana; Das, Bharati; Daware, Ashwin; Maiya, Shreesha; Jothiraj, Kannan; Ravikishore, A G

    2015-01-01

    This study was conducted to assess the acute safety and short term efficacy of renal sympathetic denervation (RSDN) using solid tip radiofrequency ablation (RFA) catheter and saline irrigation through the renal guiding catheter to achieve effective denervation. RSDN using a specialized solid-tip RFA catheter has recently been demonstrated to safely reduce systemic blood pressure in patients with refractory hypertension, the limitation being inadequate power delivery in renal arteries. So, we used solid-tip RFA catheter along with saline irrigation for RSDN. Nine patients with resistant hypertension underwent CT and conventional renal angiography, followed by bilateral or unilateral RSDN using 5F RFA catheter with saline irrigation through renal guiding catheter. Repeat renal angiography was performed at the end of the procedure. In all patients, pre- and post-procedure serum creatinine was measured. Over 1-month period: 1) the systolic/diastolic blood pressure decreased by -57 ± 20/-25 ± 7.5 mm Hg; 2) all patients experienced a decrease in systolic blood pressure of at least -36 mm Hg (range 36-98 mm Hg); 3) there was no evidence of renal artery injury immediate post-procedure. There was no significant change in serum creatinine level. This data shows the acute procedural safety and short term efficacy of RSDN using modified externally irrigated solid tip RFA catheter. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  1. Effect of heat sink on the recurrence of small malignant hepatic tumors after radiofrequency ablation.

    PubMed

    Lin, Zheng-Yu; Li, Guo-Lin; Chen, Jin; Chen, Zhong-Wu; Chen, Yi-Ping; Lin, Sun-Zhi

    2016-12-01

    The aim of this study was to investigate the effect of heat sink on the recurrence of hepatic malignant tumors <3 cm after percutaneous radiofrequency ablation (RFA). This study included 564 hepatic malignant tumors <3 cm in 381 patients. Preoperative images were used to determine whether these tumors were adjacent to vessels, and the diameter of adjacent vessels was measured. RFA was performed computed tomography (CT), magnetic resonance imaging (MRI) and ultrasound (US) guidance, and postoperative imaging follow-up was then conducted. SPSS software version 17.0 was used for data processing, and the χ2 test was used for comparative analysis. Two-sided P < 0.05 indicated statistical significance. A total of 33 recurrences were found: 15 in the MR group (15/468), 12 in the US group (12/53), and 6 in the CT group (6/43). Of the 101 lesions adjacent to blood vessels larger than 3 mm, 20 showed recurrence: 10 in the MR group (10/77), 7 in the US group (7/17), and 3 in the CT group (3/7). The recurrence rate of perivascular lesions was higher than that of nonperivascular lesions, and the rate in the MR group was lower those in the US and CT groups. The curative effect of MRI-guided RFA is better than those of US- and CT-guided ablation. The heat sink effect is an important factor affecting recurrence of hepatic malignant tumors after RFA.

  2. Snare-assisted anterograde balloon mitral and aortic valvotomy using Inoue balloon catheter.

    PubMed

    Krishnan, Mangalath N; Syamkumar, M D; Sajeev, C G; Venugopal, K; Johnson, Francis; Vinaykumar, D; Velayudhan, C C; Jayakumar, T G

    2007-01-02

    We performed concurrent antegrade mitral and aortic valvotomy using Inoue dilatation catheter in 3 cases of combined rheumatic mitral and aortic stenosis. Following mitral valvotomy by standard procedure, aortic valve was crossed with the help of a floatation catheter. Stiff long length guide wire was fixed in descending aorta using a snare. Inoue catheter was threaded over the wire across the aortic valve and aortic valvotomy completed. Mitral valve area increased from mean 1 cm2 to 2 cm2; aortic gradient dropped from mean of 97 mm to 36 mm. Concurrent anterograde balloon mitral and aortic valvotomy may be effective and safe.

  3. Special types of FBG and CoaxBG structures for telecommunication and monitoring systems

    NASA Astrophysics Data System (ADS)

    Morozov, Oleg G.; Nasybullin, Aidar R.; Morozov, Gennady A.; Danilaev, Maxim P.; Zastela, Mikhail Y.; Farkhutdinov, Rafael V.; Faskhutdinov, Lenar M.

    2015-03-01

    The technology of fiber Bragg gratings is used as one of the most applicable technologies for construction of fiber optic sensors and telecommunication systems. Periodic irregular wave resistance located in the guiding waveguide can be regarded as analog of the fiber Bragg grating structure in the field of radio-frequency. Coaxial waveguide can be used as a guide system, so a special case of this structure is the Bragg grating on coaxial cable. Recently, the special structure of sensors were beginning to be used with heterogeneity as a discrete phase π-shift. Based on the properties analysis of the Bragg reflection characteristics of structures with a phase shift in the optical and microwave range shown advantage of using these devices in measuring systems.

  4. Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study.

    PubMed

    Devito, Dennis P; Kaplan, Leon; Dietl, Rupert; Pfeiffer, Michael; Horne, Dale; Silberstein, Boris; Hardenbrook, Mitchell; Kiriyanthan, George; Barzilay, Yair; Bruskin, Alexander; Sackerer, Dieter; Alexandrovsky, Vitali; Stüer, Carsten; Burger, Ralf; Maeurer, Johannes; Donald, Gordon D; Gordon, Donald G; Schoenmayr, Robert; Friedlander, Alon; Knoller, Nachshon; Schmieder, Kirsten; Pechlivanis, Ioannis; Kim, In-Se; Meyer, Bernhard; Shoham, Moshe

    2010-11-15

    Retrospective, multicenter study of robotically-guided spinal implant insertions. Clinical acceptance of the implants was assessed by intraoperative radiograph, and when available, postoperative computed tomography (CT) scans were used to determine placement accuracy. To verify the clinical acceptance and accuracy of robotically-guided spinal implants and compare to those of unguided free-hand procedures. SpineAssist surgical robot has been used to guide implants and guide-wires to predefined locations in the spine. SpineAssist which, to the best of the authors' knowledge, is currently the sole robot providing surgical assistance in positioning tools in the spine, guided over 840 cases in 14 hospitals, between June 2005 and June 2009. Clinical acceptance of 3271 pedicle screws and guide-wires inserted in 635 reported cases was assessed by intraoperative fluoroscopy, where placement accuracy of 646 pedicle screws inserted in 139 patients was measured using postoperative CT scans. Screw placements were found to be clinically acceptable in 98% of the cases when intraoperatively assessed by fluoroscopic images. Measurements derived from postoperative CT scans demonstrated that 98.3% of the screws fell within the safe zone, where 89.3% were completely within the pedicle and 9% breached the pedicle by up to 2 mm. The remaining 1.4% of the screws breached between 2 and 4 mm, while only 2 screws (0.3%) deviated by more than 4 mm from the pedicle wall. Neurologic deficits were observed in 4 cases yet, following revisions, no permanent nerve damage was encountered, in contrast to the 0.6% to 5% of neurologic damage reported in the literature. SpineAssist offers enhanced performance in spinal surgery when compared to free-hand surgeries, by increasing placement accuracy and reducing neurologic risks. In addition, 49% of the cases reported herein used a percutaneous approach, highlighting the contribution of SpineAssist in procedures without anatomic landmarks.

  5. Shuttleless toroid winder

    DOEpatents

    Lindenmeyer, Carl W.

    1981-01-01

    A lower support receives a toroid at a winding station with the axis of the toroid aligned with a slot in the support. An upper guide member applies an axial force to hold the toroid against the lower support. A pair of movable jaws carried by an indexing mechanism engage the outer surface of the toroid to apply a radial holding force. While the toroid is thus held, a wire is placed axially through the toroid, assisted by a funnel-shaped surface in the upper guide member, and is drawn tight about the toroid by a pair of cooperating draw rollers. When operated in the "full cycle" mode, the operator then actuates a switch which energizes a power drive to release the axial clamp and to drive the indexing mechanism and the jaws to rotate the toroid about its axis. At the same time, the wire is ejected from the draw rollers beneath the toroid so that the operator may grasp it to form another loop. When the toroid is fully indexed, the jaws release it, and the upper guide member is returned to clamp the toroid axially while the indexing mechanism is returned to its starting position. The apparatus may also be operated in a "momentary contact" mode in which the mechanism is driven only for the time a switch is actuated.

  6. Esophageal stenosis in epidermolysis bullosum: a challenge for the endoscopist.

    PubMed

    De Angelis, Paola; Caldaro, Tamara; Torroni, Filippo; Romeo, Erminia; Foschia, Francesca; di Abriola, Giovanni Federici; Rea, Francesca; El Hachem, May; Genovese, Elisabetta; D'Alessandro, Sandra; Dall'Oglio, Luigi

    2011-05-01

    Esophageal stenosis is a severe complication in dystrophic epidermolysis bullosa (EB). Endoscopic dilations may cause mucosal injury with stricture recurrence. Our aim was to describe our referral EB-center experience on safety and long-term efficacy of fluoroscopically guided balloon dilation without endoscopy. Over 14 years, 34 patients with EB, previously evaluated with barium esophagogram for dysphagia, underwent balloon esophageal dilation. Under fluoroscopy, a guide wire was introduced via a nostril into the stomach. A 12-mm pneumatic balloon, which passed over the wire, was filled using radio-opaque contrast, dilating the stricture. Orotracheal intubation was avoided. Antibiotics, dexamethasone, and proton-pump inhibitors were administered. Study approval was obtained from our ethical board. Ninety-three dilations were performed. Seventeen patients had a single stenosis. The mean age of onset was 18 years (range, 3-47 years). Thirteen patients underwent one dilation. In 6 cases, endoscopy was necessary to visualize the esophageal lumen. Complications included cervical esophageal perforation (2) and transitory dysphagia (10). Thirty patients were feeding within 24 hours. During the follow-up, 2 patients required a gastrostomy, and 2 patients underwent fundoplication for gastroesophageal reflux disease. Fluoroscopically guided balloon dilation in EB is a safe and well-tolerated procedure. An experienced endoscopy team is necessary in certain cases. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Successful retrieval of an entrapped Rotablator burr using 5 Fr guiding catheter.

    PubMed

    Kimura, Masayoshi; Shiraishi, Jun; Kohno, Yoshio

    2011-10-01

    Although burr entrapment is a rare complication of the Rotablator, it is extremely difficult to retrieve a fixedly entrapped burr without surgical procedure. An 84-year-old male with effort angina had heavily calcified coronary trees as well as severe stenosis in the mid LCx, and moderate stenosis in the proximal LCx, and in the LMT. We planned to perform rotational atherectomy in the LCx lesions. Using 7 Fr Q-curve guiding catheter and Rotawire floppy, we began to ablate using 1.5-mm burr at 200,000 rpm. Because the burr could not pass the proximal stenosis, we exchanged the wire for Rotawire extrasupport and the burr for 1.25-mm burr, and restarted the ablation at 220,000 rpm. Although the burr could manage to pass the proximal stenosis, it had become trapped in the mid LCx lesion. Simple pull on the Rotablator, rotation of the burr, and crossing the Conquest (Confianza) wire could not retrieve it. Thus, we cut off the drive shaft and sheath of the Rotablator, inserted 5 Fr 120-cm straight guiding catheter (Heartrail ST01; Terumo) through the remaining Rotablator system, pushed the catheter tip to the lesion around the burr as well as simultaneously pulled the Rotablator, and finally could retrieve it. Then we implanted stents in the LCx and in the LMT without difficulty. The 5 Fr straight guiding catheter might be useful for retrieving an entrapped burr (1.25-mm burr). Copyright © 2011 Wiley-Liss, Inc.

  8. Interventional articular and para-articular knee procedures

    PubMed Central

    Lalam, Radhesh K; Winn, Naomi

    2016-01-01

    The knee is a common area of the body to undergo interventional procedures. This article discusses image-guided interventional issues specific to the knee area. The soft tissues in and around the knee are frequently affected by sport-related injuries and often need image-guided intervention. This article details the specific technical issues related to intervention in these soft tissues, including the iliotibial tract, fat pads, patellar tendon and other tendons, bursae and the meniscus. Most often, simple procedures such as injection and aspiration are performed without image guidance. Rarely image-guided diagnostic arthrography and therapeutic joint injections are necessary. The technique, indications and diagnostic considerations for arthrography are discussed in this article. Primary bone and soft-tissue tumours may involve the knee and adjacent soft tissues. Image-guided biopsies are frequently necessary for these lesions; this article details the technical issues related to image-guided biopsy around the knee. A number of newer ablation treatments are now available, including cryoablation, high-frequency ultrasound and microwave ablation. Radiofrequency ablation, however, still remains the most commonly employed ablation technique. The indications, technical and therapeutic considerations related to the application of this technique around the knee are discussed here. Finally, we briefly discuss some newer, but as of yet, unproven image-guided interventions for osteochondral lesions and Brodie's abscess. PMID:26682669

  9. Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers.

    PubMed

    Malham, Gregory M; Parker, Rhiannon M

    2018-04-01

    OBJECTIVE Image guidance for spine surgery has been reported to improve the accuracy of pedicle screw placement and reduce revision rates and radiation exposure. Current navigation and robot-assisted techniques for percutaneous screws rely on bone-anchored trackers and Kirchner wires (K-wires). There is a paucity of published data regarding the placement of image-guided percutaneous screws without K-wires. A new skin-adhesive stereotactic patient tracker (SpineMask) eliminates both an invasive bone-anchored tracker and K-wires for pedicle screw placement. This study reports the authors' early experience with the use of SpineMask for "K-wireless" placement of minimally invasive pedicle screws and makes recommendations for its potential applications in lumbar fusion. METHODS Forty-five consecutive patients (involving 204 screws inserted) underwent K-wireless lumbar pedicle screw fixation with SpineMask and intraoperative neuromonitoring. Screws were inserted by percutaneous stab or Wiltse incisions. If required, decompression with or without interbody fusion was performed using mini-open midline incisions. Multimodality intraoperative neuromonitoring assessing motor and sensory responses with triggered electromyography (tEMG) was performed. Computed tomography scans were obtained 2 days postoperatively to assess screw placement and any cortical breaches. A breach was defined as any violation of a pedicle screw involving the cortical bone of the pedicle. RESULTS Fourteen screws (7%) required intraoperative revision. Screws were removed and repositioned due to a tEMG response < 13 mA, tactile feedback, and 3D fluoroscopic assessment. All screws were revised using the SpineMask with the same screw placement technique. The highest proportion of revisions occurred with Wiltse incisions (4/12, 33%) as this caused the greatest degree of SpineMask deformation, followed by a mini midline incision (3/26, 12%). Percutaneous screws via a single stab incision resulted in the fewest revisions (7/166, 4%). Postoperative CT demonstrated 7 pedicle screw breaches (3%; 5 lateral, 1 medial, 1 superior), all with percutaneous stab incisions (7/166, 4%). The radiological accuracy of the SpineMask tracker was 97% (197/204 screws). No patients suffered neural injury or required postoperative screw revision. CONCLUSIONS The noninvasive cutaneous SpineMask tracker with 3D image guidance and tEMG monitoring provided high accuracy (97%) for percutaneous pedicle screw placement via stab incisions without K-wires.

  10. Infrared transmission of electronic information via LAN in the operating room.

    PubMed

    Hagihira, S; Takashina, M; Mori, T; Taenaka, N; Mashimo, T; Yoshiya, I

    2000-01-01

    Recent advances in technology have brought many kinds of monitoring devices into the operating room (OR). The information gathered by monitors can be channeled to the operating ward information system via a local area network (LAN). Connecting patients to monitors and monitors to the LAN, however, requires a large number of cables. This wiring is generally inconvenient and particularly troublesome if the layout of the OR is rearranged. From this point of view, wireless transmission seems ideally suited to clinical settings. Currently, two modes of wireless connectivity are available: radio-frequency (RF) waves or infrared (IR) waves. Some reports suggest that RF transmission is likely to cause electromagnetic interference (EMI) in medical devices such as cardiac pacemakers or infusion pumps. The risk of malfunctioning life-sustaining devices and the catastrophic consequences this would have on seriously ill patients rules out the use of RF. Here, we report an IR system using IR modems for LAN connectivity in the OR. In this study, we focused on the possible detrimental effects of EMI during wireless connectivity. In our trial, we found no evidence of EMI of IR modems with any of the medical devices we tested. Furthermore, IR modems showed similar performance to a wired system even in an electrically noisy environment. We conclude that IR wireless connectivity can be safely and effectively used in ORs.

  11. Advancement of wave generation and signal transmission in wire waveguides for structural health monitoring applications

    NASA Astrophysics Data System (ADS)

    Kropf, M.; Pedrick, M.; Wang, X.; Tittmann, B. R.

    2005-05-01

    As per the recent advances in remote in situ monitoring of industrial equipment using long wire waveguides (~10m), novel applications of existing wave generation techniques and new acoustic modeling software have been used to advance waveguide technology. The amount of attainable information from an acoustic signal in such a system is limited by transmission through the waveguide along with frequency content of the generated waves. Magnetostrictive, and Electromagnetic generation techniques were investigated in order to maximize acoustic transmission along the waveguide and broaden the range of usable frequencies. Commercial EMAT, Magnetostrictive and piezoelectric disc transducers (through the innovative use of an acoustic horn) were utilized to generate waves in the wire waveguide. Insertion loss, frequency bandwidth and frequency range were examined for each technique. Electromagnetic techniques are shown to allow for higher frequency wave generation. This increases accessibility of dispersion curves providing further versatility in the selection of guided wave modes, thus increasing the sensitivity to physical characteristics of the specimen. Both electromagnetic and magnetostrictive transducers require the use of a ferromagnetic waveguide, typically coupled to a steel wire when considering long transmission lines (>2m). The interface between these wires introduces an acoustic transmission loss. Coupling designs were examined with acoustic finite element software (Coupled-Acoustic Piezoelectric Analysis). Simulations along with experimental results aided in the design of a novel joint which minimizes transmission loss. These advances result in the increased capability of remote sensing using wire waveguides.

  12. Improvement in the transport critical current density and microstructure of isotopic Mg11B2 monofilament wires by optimizing the sintering temperature

    PubMed Central

    Qiu, Wenbin; Jie, Hyunseock; Patel, Dipak; Lu, Yao; Luzin, Vladimir; Devred, Arnaud; Somer, Mehmet; Shahabuddin, Mohammed; Kim, Jung Ho; Ma, Zongqing; Dou, Shi Xue; Hossain, Md. Shahriar Al

    2016-01-01

    Superconducting wires are widely used in fabricating magnetic coils in fusion reactors. In consideration of the stability of 11B against neutron irradiation and lower induced radio-activation properties, MgB2 superconductor with 11B serving as boron source is an alternative candidate to be used in fusion reactor with severe irradiation environment. In present work, a batch of monofilament isotopic Mg11B2 wires with amorphous 11B powder as precursor were fabricated using powder-in-tube (PIT) process at different sintering temperature, and the evolution of their microstructure and corresponding superconducting properties was systemically investigated. Accordingly, the best transport critical current density (Jc) = 2 × 104 A/cm2 was obtained at 4.2 K and 5 T, which is even comparable to multi-filament Mg11B2 isotope wires reported in other work. Surprisingly, transport Jc vanished in our wire which was heat-treated at excessively high temperature (800 °C). Combined with microstructure observation, it was found that lots of big interconnected microcracks and voids that can isolate the MgB2 grains formed in this whole sample, resulting in significant deterioration in inter-grain connectivity. The results can be a constructive guide in fabricating Mg11B2 wires to be used as magnet coils in fusion reactor systems such as ITER-type tokamak magnet. PMID:27824144

  13. Planning for Technology: An Administrator's Guide to the Next Century.

    ERIC Educational Resources Information Center

    Day, William C.

    1998-01-01

    Discusses ways for preparing schools for integrating technology, including designing the wiring infrastructure, equipment purchases, furniture needs, and ergonomic considerations. Describes four levels of Internet connectivity access and provides a list of contact names, phone numbers, and Web sites for technology fund information from each state.…

  14. Rocket center Peenemuende - Personal memories

    NASA Technical Reports Server (NTRS)

    Dannenberg, Konrad; Stuhlinger, Ernst

    1993-01-01

    A brief history of Peenemuende, the rocket center where Von Braun and his team developed the A-4 (V-2) rocket under German Army auspices, and the Air Force developed the V-1 (buzz bomb), wire-guided bombs, and rocket planes, is presented. Emphasis is placed on the expansion of operations beginning in 1942.

  15. From nodal-ring topological superfluids to spiral Majorana modes in cold atomic systems

    NASA Astrophysics Data System (ADS)

    He, Wen-Yu; Xu, Dong-Hui; Zhou, Benjamin T.; Zhou, Qi; Law, K. T.

    2018-04-01

    In this work, we consider a three-dimensional (3D) cubic optical lattice composed of coupled 1D wires with 1D spin-orbit coupling. When the s -wave pairing is induced through Feshbach resonance, the system becomes a topological superfluid with ring nodes, which are the ring nodal degeneracies in the bulk, and supports a large number of surface Majorana zero-energy modes. The large number of surface Majorana modes remain at zero energy even in the presence of disorder due to the protection from a chiral symmetry. When the chiral symmetry is broken, the system becomes a Weyl topological superfluid with Majorana arcs. With 3D spin-orbit coupling, the Weyl superfluid becomes a gapless phase with spiral Majorana modes on the surface. A spatial-resolved radio-frequency spectroscopy is suggested to detect this nodal-ring topological superfluid phase.

  16. Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement.

    PubMed

    Hananouchi, Takehito; Saito, Masanobu; Koyama, Tsuyoshi; Sugano, Nobuhiko; Yoshikawa, Hideki

    2010-04-01

    Malalignment of the cup in total hip arthroplasty (THA) increases the risks of postoperative complications such as neck cup impingement, dislocation, and wear. We asked whether a tailor-made surgical guide based on CT images would reduce the incidence of outliers beyond 10 degrees from preoperatively planned alignment of the cup compared with those without the surgical guide. We prospectively followed 38 patients (38 hips, Group 1) having primary THA with the conventional technique and 31 patients (31 hips, Group 2) using the surgical guide. We designed the guide for Group 2 based on CT images and fixed it to the acetabular edge with a Kirschner wire to indicate the planned cup direction. Postoperative CT images showed the guide reduced the number of outliers compared with the conventional method (Group 1, 23.7%; Group 2, 0%). The surgical guide provided more reliable cup insertion compared with conventional techniques. Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  17. Integrated RFA/OCT catheter for real-time guidance of cardiac RFA therapy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Fu, Xiaoyong; Blumenthal, Colin; Dosluoglu, Deniz; Wang, Yves T.; Jenkins, Michael W.; Souza, Rakesh; Snyder, Christopher; Arruda, Mauricio; Rollins, Andrew M.

    2016-03-01

    Currently, cardiac radiofrequency ablation is guided by indirect signals. We demonstrate an integrated radiofrequency ablation (RFA) and optical coherence tomography (OCT) probe for directly monitoring of the RFA procedure with OCT images in real time. The integrated RFA/OCT probe is modified from a standard commercial RFA catheter, and a newly designed and fabricated miniature forward-viewing cone-scanning OCT probe is integrated into the modified probe. The OCT system is verified with the human finger images, and the results show the integrated RFA/OCT probe can acquire high quality OCT images. The radiofrequency energy delivering function of the integrated probe is verified by comparing the RFA lesion sizes with standard commercial RFA probe. For the standard commercial probe, the average width and depth of the 10 lesions were 3.5 mm and 1.8 mm respectively. For the integrated RFA/OCT probe, the average width and depth of the 10 lesions were 3.6 mm and 1.7 mm respectively. The lesions created by the two probes are indistinguishable in size. This demonstrates that our glass window in the integrated probe has little effect on the RF energy delivery. And the integrated probe is used to monitoring the cardiac RFA procedure in real time. The results show that the RFA lesion formation can be confirmed by the loss of birefringence in the heart tissue. The system can potentially in vivo image of the cardiac wall to aid RFA therapy for cardiac arrhythmias.

  18. Microendoscopic stereotactic-guided percutaneous radiofrequency trigeminal nucleotractotomy.

    PubMed

    Teixeira, Manoel Jacobsen; de Almeida, Fabrício Freitas; de Oliveira, Ywzhe Sifuentes Almeida; Fonoff, Erich Talamoni

    2012-02-01

    Over the past few decades, various authors have performed open or stereotactic trigeminal nucleotractotomy for the treatment of neuropathic facial pain resistant to medical treatment. Stereotactic procedures can be performed percutaneously under local anesthesia, allowing intraoperative neurological examination as a method for target refinement. However, blind percutaneous procedures in the region of the atlantooccipital transition carry a considerably high risk of vascular injuries that may bring prohibitive neurological deficit or even death. To avoid such complications, the authors present the first clinical use of microendoscopy to assist percutaneous radiofrequency trigeminal nucleotractotomy. The aim of this article is to demonstrate intradural microendoscopic visualization of the medulla oblongata through an atlantooccipital percutaneous approach. The authors present a case of severe postherpetic facial neuralgia in a patient who underwent the procedure and had satisfactory results. Stereotactic computational image planning for targeting the spinal trigeminal tract and nucleus in the posterolateral medulla was performed, allowing for an accurate percutaneous approach. Immediately before radiofrequency electrode insertion, a fine endoscope was introduced to visualize the structures in the cisterna magna. Microendoscopic visualization offered clear identification of the pial surface of the medulla oblongata and its blood vessels, the arachnoid membrane, cranial nerve rootlets and their entry zone, and larger vessels such as the vertebral arteries and the branches of the posterior inferior cerebellar artery. The initial application of this technique suggests that percutaneous microendoscopy may be useful for particular manipulation of the medulla oblongata, increasing the safety of the procedure and likely improving its effectiveness.

  19. The relationship of lateral anatomic structures to exiting guide pins during femoral tunnel preparation utilizing an accessory medial portal.

    PubMed

    Farrow, Lutul D; Parker, Richard D

    2010-06-01

    Anatomic reconstruction of the anterior cruciate ligament through an accessory medial portal has become increasingly popular. The purpose of this study is to describe the relationship of guide pin exit points to the lateral anatomic structures when preparing the anterior cruciate ligament femoral tunnel through an accessory medial portal. We utilized seven fresh frozen cadaveric knees. Utilizing an anteromedial approach, a guide wire was placed into the center of each bundle's footprint. Each guide wire was advanced through the lateral femoral cortex. The guide pins were passed at 90, 110, and 130 degrees of knee flexion. The distances from each guide pin to the closest relevant structures on the lateral side of the knee were measured. At 90 degrees the posterolateral bundle guide pin was closest to the lateral condyle articular cartilage (mean 5.4 +/- 2.2 mm) and gastrocnemius tendon (mean 5.7 +/- 2.1 mm). At 110 degrees the posterolateral bundle pin was closest to the gastrocnemius tendon (mean 4.5 +/- 3.4 mm). At 130 degrees the posterolateral bundle pin was closest to the gastrocnemius tendon (mean 7.2 +/- 5.5 mm) and lateral collateral ligament (mean 6.8 +/- 2.1 mm). At 90 degrees the anteromedial bundle guide pin was closest to the articular cartilage (mean 2.0 +/- 2.0 mm). At 110 degrees the anteromedial bundle pin was closest to the articular cartilage (mean 7.4 +/- 3.5 mm) and gastrocnemius tendon (mean 12.3 +/- 3.1 mm). At 130 degrees the AM bundle pin was closest to the gastrocnemius tendon (mean 8.2 +/- 3.2 mm) and LCL (mean 15.1 +/- 2.9 mm). Neither guide pin (anteromedial or posterolateral bundle) put the peroneal nerve at risk at any knee flexion angle. At low knee flexion angles the anteromedial and posterolateral bundle guide pins closely approximated multiple lateral structures when using an accessory medial arthroscopic portal. Utilizing higher flexion angles increases the margin of error when preparing both femoral tunnels. During preparation of the anterior cruciate ligament femoral tunnel through an accessory anteromedial portal the tunnels should be drilled in at least 110 degrees of knee flexion in order to move guide pin exit points away from important lateral knee structures.

  20. Development of automatic pre-tracking system for fillet weld based on laser trigonometry

    NASA Astrophysics Data System (ADS)

    Shen, Xiaoqin; Yu, Fusheng

    2005-01-01

    In this paper, an automatic fillet weld pre-tracking system for welding the work piece of lorry back boards with several bend in haul automobile is developed basing on laser trigonometry. The optical measuring head based on laser-PSD trigonometry is used as position sensor. It is placed in front of the traveling direction of welding wire to get the distances from welding wire to the two side boards of the welding lines, upper board and bottom board of the fillet weld respectively. A chip of AT89S52 is used as the micro controller in this system. The AC servomotors, ball-screws and straight guide rails constitute the sliding table to take welding wire move. The laser-PSD sensors pass through the vertical board, upper board and bottom board of the fillet weld when welding wire moves and then get the distance. The laser-PSD sensors output the analog signals. After A/D conversion, the digital signal is input into AT89S52 and calculated. Then the information of the position and lateral deviation of the welding wire when welding a certain position are gotten to control welding wires. So the weld pre-tracking for welding the work piece with long distance and large bend in haul automobile is realized. The position information is input into EEPROM to be saved for short time after handled by AT89S52. The information is as the welding position information as well as the speed adjusting data of the welding wire when it welds the several bend of the work piece. The practice indicates that this system has high pre-tracking precision, good anti-disturb ability, excellent reliability, easy operating ability and good adaptability to the field of production.

  1. Measurements of Radiofrequency Radiation with a Body-Borne Exposimeter in Swedish Schools with Wi-Fi.

    PubMed

    Hedendahl, Lena K; Carlberg, Michael; Koppel, Tarmo; Hardell, Lennart

    2017-01-01

    Wireless access to the Internet is now commonly used in schools. Many schools give each student their own laptop and utilize the laptops and wireless fidelity (Wi-Fi) connection for educational purposes. Most children also bring their own mobile phones to school. Since children are obliged by law to attend school, a safe environment is important. Lately, it has been discussed if radiofrequency (RF) radiation can have long-term adverse effects on children's health. This study conducted exposimetric measurements in schools to assess RF emissions in the classroom by measuring the teachers' RF exposure in order to approximate the children's exposure. Teachers in grades 7-12 carried a body-borne exposimeter, EME-Spy 200, in school during 1-4 days of work. The exposimeter can measure 20 different frequency bands from 87 to 5,850 MHz. Eighteen teachers from seven schools participated. The mean exposure to RF radiation ranged from 1.1 to 66.1 µW/m 2 . The highest mean level, 396.6 µW/m 2 , occurred during 5 min of a lesson when the teacher let the students stream and watch YouTube videos. Maximum peaks went up to 82,857 µW/m 2 from mobile phone uplink. Our measurements are in line with recent exposure studies in schools in other countries. The exposure levels varied between the different Wi-Fi systems, and if the students were allowed to use their own smartphones on the school's Wi-Fi network or if they were connected to GSM/3G/4G base stations outside the school. An access point over the teacher's head gave higher exposure compared with a school with a wired Internet connection for the teacher in the classroom. All values were far below International Commission on Non-Ionizing Radiation Protection's reference values, but most mean levels measured were above the precautionary target level of 3-6 µW/m 2 as proposed by the Bioinitiative Report. The length of time wireless devices are used is an essential determinant in overall exposure. Measures to minimize children's exposure to RF radiation in school would include preferring wired connections, allowing laptops, tablets and mobile phones only in flight mode and deactivating Wi-Fi access points, when not used for learning purposes.

  2. Reliability analysis of magnetic logic interconnect wire subjected to magnet edge imperfections

    NASA Astrophysics Data System (ADS)

    Zhang, Bin; Yang, Xiaokuo; Liu, Jiahao; Li, Weiwei; Xu, Jie

    2018-02-01

    Nanomagnet logic (NML) devices have been proposed as one of the best candidates for the next generation of integrated circuits thanks to its substantial advantages of nonvolatility, radiation hardening and potentially low power. In this article, errors of nanomagnetic interconnect wire subjected to magnet edge imperfections have been evaluated for the purpose of reliable logic propagation. The missing corner defects of nanomagnet in the wire are modeled with a triangle, and the interconnect fabricated with various magnetic materials is thoroughly investigated by micromagnetic simulations under different corner defect amplitudes and device spacings. The results show that as the defect amplitude increases, the success rate of logic propagation in the interconnect decreases. More results show that from the interconnect wire fabricated with materials, iron demonstrates the best defect tolerance ability among three representative and frequently used NML materials, also logic transmission errors can be mitigated by adjusting spacing between nanomagnets. These findings can provide key technical guides for designing reliable interconnects. Project supported by the National Natural Science Foundation of China (No. 61302022) and the Scientific Research Foundation for Postdoctor of Air Force Engineering University (Nos. 2015BSKYQD03, 2016KYMZ06).

  3. Minimum depth of investigation for grounded-wire TEM due to self-transients

    NASA Astrophysics Data System (ADS)

    Zhou, Nannan; Xue, Guoqiang

    2018-05-01

    The grounded-wire transient electromagnetic method (TEM) has been widely used for near-surface metalliferous prospecting, oil and gas exploration, and hydrogeological surveying in the subsurface. However, it is commonly observed that such TEM signal is contaminated by the self-transient process occurred at the early stage of data acquisition. Correspondingly, there exists a minimum depth of investigation, above which the observed signal is not applicable for reliable data processing and interpretation. Therefore, for achieving a more comprehensive understanding of the TEM method, it is necessary to perform research on the self-transient process and moreover develop an approach for quantifying the minimum detection depth. In this paper, we first analyze the temporal procedure of the equivalent circuit of the TEM method and present a theoretical equation for estimating the self-induction voltage based on the inductor of the transmitting wire. Then, numerical modeling is applied for building the relationship between the minimum depth of investigation and various properties, including resistivity of the earth, offset, and source length. It is guide for the design of survey parameters when the grounded-wire TEM is applied to the shallow detection. Finally, it is verified through applications to a coal field in China.

  4. Pressure-assisted melt-filling and optical characterization of Au nano-wires in microstructured fibers.

    PubMed

    Lee, H W; Schmidt, M A; Russell, R F; Joly, N Y; Tyagi, H K; Uebel, P; Russell, P St J

    2011-06-20

    We report a novel splicing-based pressure-assisted melt-filling technique for creating metallic nanowires in hollow channels in microstructured silica fibers. Wires with diameters as small as 120 nm (typical aspect ration 50:1) could be realized at a filling pressure of 300 bar. As an example we investigate a conventional single-mode step-index fiber with a parallel gold nanowire (wire diameter 510 nm) running next to the core. Optical transmission spectra show dips at wavelengths where guided surface plasmon modes on the nanowire phase match to the glass core mode. By monitoring the side-scattered light at narrow breaks in the nanowire, the loss could be estimated. Values as low as 0.7 dB/mm were measured at resonance, corresponding to those of an ultra-long-range eigenmode of the glass-core/nanowire system. By thermal treatment the hollow channel could be collapsed controllably, permitting creation of a conical gold nanowire, the optical properties of which could be monitored by side-scattering. The reproducibility of the technique and the high optical quality of the wires suggest applications in fields such as nonlinear plasmonics, near-field scanning optical microscope tips, cylindrical polarizers, optical sensing and telecommunications.

  5. Laser speckle imaging to improve clinical outcomes for patients with trigeminal neuralgia undergoing radiofrequency thermocoagulation.

    PubMed

    Ringkamp, Matthias; Wooten, Matthew; Carson, Benjamin S; Lim, Michael; Hartke, Timothy; Guarnieri, Michael

    2016-02-01

    Percutaneous treatments for trigeminal neuralgia are safe, simple, and effective for achieving good pain control. Procedural risks could be minimized by using noninvasive imaging techniques to improve the placement of the radiofrequency thermocoagulation probe into the trigeminal ganglion. Positioning of a probe is crucial to maximize pain relief and to minimize unwanted side effects, such as denervation in unaffected areas. This investigation examined the use of laser speckle imaging during probe placement in an animal model. This preclinical safety study used nonhuman primates, Macaca nemestrina (pigtail monkeys), to examine whether real-time imaging of blood flow in the face during the positioning of a coagulation probe could monitor the location and guide the positioning of the probe within the trigeminal ganglion. Data from 6 experiments in 3 pigtail monkeys support the hypothesis that laser imaging is safe and improves the accuracy of probe placement. Noninvasive laser speckle imaging can be performed safely in nonhuman primates. Because improved probe placement may reduce morbidity associated with percutaneous rhizotomies, efficacy trials of laser speckle imaging should be conducted in humans.

  6. Radiofrequency Ablation in Combination with Embolization in Metachronous Recurrent Renal Cancer in Solitary Kidney after Contralateral Tumor Nephrectomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gebauer, Bernhard, E-mail: bernhard.gebauer@charite.de; Werk, Michael; Lopez-Haenninen, Enrique

    Purpose. To evaluate the feasibility and safety of minimally invasive, percutaneous techniques in metachronous recurrent renal cell cancers (RCCs) in solitary kidneys. Methods. In 4 patients, recurrent RCC was treated by radiofrequency ablation (RFA) (RITA, StarBurst) alone, and in 2 patients by RFA in combination with superselective transarterial particle-lipiodol embolization using 3 Fr microcatheters. RFA was guided by computed tomography in 5 patients, and by magnetic resonance imaging in 1 patient. Mean tumor diameter was 26.7 mm (range 10-45 mm). All interventions were technically successful; during follow-up 1 patient developed recurrent RCC, which was retreated by RFA after embolization. Results.more » No major peri- or postprocedural complications occurred. Changes in creatinine (pre- vs. post-intervention, 122 vs. 127 {mu}mol/l) and calculated creatinine clearance (pre- vs. post-intervention, 78 vs. 73 ml/min) after ablation were minimal. Conclusion. In single kidneys, percutaneous, minimally invasive techniques are safe and feasible. In large tumors, or where there are adjacent critical structures, we prefer a combination of embolization and thermal ablation (RFA)« less

  7. Challenges in Radiofrequency Pasteurization of Shell Eggs: Coagulation Rings.

    PubMed

    Lau, Soon Kiat; Thippareddi, Harshavardhan; Jones, David; Negahban, Mehrdad; Subbiah, Jeyamkondan

    2016-10-01

    A total of 50 different configurations of simple radiofrequency (RF) heating at 27.12 MHz of a shell egg were simulated using a finite element model with the purpose of pasteurizing the egg. Temperature-dependent thermal and dielectric properties of the yolk, albumen, and shell were measured, fitted, and introduced into the model. A regression equation that relates the top electrode voltage to the gap between the electrodes and vertical position of the egg was developed. Simulation and experimental results had good agreement in terms of temperature deviation (root mean squared error ranged from 0.35 °C to 0.48 °C) and both results demonstrated the development of a "coagulation ring" around the air cell. The focused heating near the air cell of the egg prevented pasteurization of the egg due to its impact on quality (coagulation). Analysis of the electric field patterns offered a perspective on how nonuniform RF heating could occur in heterogeneous food products. The results can be used to guide development of RF heating for heterogeneous food products and further development of RF pasteurization of eggs. © 2016 Institute of Food Technologists®.

  8. Guide wire extension for shape memory polymer occlusion removal devices

    DOEpatents

    Maitland, Duncan J [Pleasant Hill, CA; Small, IV, Ward; Hartman, Jonathan [Sacramento, CA

    2009-11-03

    A flexible extension for a shape memory polymer occlusion removal device. A shape memory polymer instrument is transported through a vessel via a catheter. A flexible elongated unit is operatively connected to the distal end of the shape memory polymer instrument to enhance maneuverability through tortuous paths en route to the occlusion.

  9. Wired for the Future: Developing Your Library Technology Plan.

    ERIC Educational Resources Information Center

    Mayo, Diane; Nelson, Sandra

    A technology plan provides a blueprint against which to measure new technologies and applications, assess future needs, and allocate resources to balance technology with the needs of users and staff. This book is a comprehensive and practical guide for librarians preparing a technology plan. The book is divided into five planning steps, each of…

  10. Manual tube-to-tubesheet welding torch

    DOEpatents

    Kiefer, Joseph H.; Smith, Danny J.

    1982-01-01

    A welding torch made of a high temperature plastic which fits over a tube intermediate the ends thereof for welding the juncture between the tube and the back side of a tube plate and has a ballooned end in which an electrode, filler wire guide, fiber optic bundle, and blanketing gas duct are disposed.

  11. Trade Electricity. Motors & Controls--Level 3. Standardized Curriculum.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY. Office of Occupational and Career Education.

    This curriculum guide consists of seven modules on motors and controls, one of the three divisions of the standardized trade electricity curriculum in high schools in New York City. The seven modules cover the following subjects: energy conservation wiring, direct current (DC) motor repair and rewinding, DC motor controls, alternating current (AC)…

  12. 16 CFR § 1500.43 - Method of test for flashpoint of volatile flammable materials by Tagliabue open-cup apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... is placed snugly in holes drilled in the rim of the bath, so that the guide wire is 5/8-inch from the... black. Procedure 4. (a) Place the tester on a solid table free of vibration, in a location free of...

  13. High-Velocity Impact Fragmentation of Projectiles Experimental Results

    DTIC Science & Technology

    2016-10-01

    Program (JIMTP) Tube -Launched, Optically Tracked, Wire-Guided (TOW) 2B Insensitive Munitions (IM) Warhead effort. The referenced experiments were...conducted to determine the velocity reduction and fragmentation profile of barrier materials subjected to impact by the IM Fragment Impact (FI) test...9 LIST OF TABLES Table Title Page 1. Single Material Test Matrix

  14. A Curriculum Package for Implementing Instruction in Electricity Fundamentals/House Wiring.

    ERIC Educational Resources Information Center

    Murphy, Brian P.

    This curriculum guide is designed for instructors of secondary industrial arts, vocational, and apprenticeship programs. The material is presented in two sections. Section I provides step-by-step instructions on how to present basic electrical circuit concepts with the use of a simply-made breadboard. Included in this section is the following…

  15. Retail Florist: Selling the Floral Product, Maintenance and Delivery.

    ERIC Educational Resources Information Center

    Southern Illinois Univ., Carbondale.

    This retail florist unit guide is provided to help teachers teach units on sales of floral products and maintenance and delivery in a floral shop. Topics covered in the selling unit are basic mathematics; taxable items; sales etiquette; types of floral products; telephone etiquette; order form information; wire service regulations; care of floral…

  16. Metal wires for terahertz wave guiding.

    PubMed

    Wang, Kanglin; Mittleman, Daniel M

    2004-11-18

    Sources and systems for far-infrared or terahertz (1 THz = 10(12) Hz) radiation have received extensive attention in recent years, with applications in sensing, imaging and spectroscopy. Terahertz radiation bridges the gap between the microwave and optical regimes, and offers significant scientific and technological potential in many fields. However, waveguiding in this intermediate spectral region still remains a challenge. Neither conventional metal waveguides for microwave radiation, nor dielectric fibres for visible and near-infrared radiation can be used to guide terahertz waves over a long distance, owing to the high loss from the finite conductivity of metals or the high absorption coefficient of dielectric materials in this spectral range. Furthermore, the extensive use of broadband pulses in the terahertz regime imposes an additional constraint of low dispersion, which is necessary for compatibility with spectroscopic applications. Here we show how a simple waveguide, namely a bare metal wire, can be used to transport terahertz pulses with virtually no dispersion, low attenuation, and with remarkable structural simplicity. As an example of this new waveguiding structure, we demonstrate an endoscope for terahertz pulses.

  17. Interventional Management of “Balloon-Uncrossable” Coronary Chronic Total Occlusion: Is There Any Way Out?

    PubMed Central

    2018-01-01

    It has been estimated that coronary chronic total occlusion (CTO) is encountered in 15 to 20% patients referred for coronary angiography (CAG). The success of percutaneous coronary intervention (PCI) of CTO can be attributed to the vast array of hardware that has now become available and also to the vastly enhanced operator expertise. It is however realistic to state that despite the tremendous increase in the rate of success, there then comes a subset of CTO where PCI attempts fail. The reason for such failures given that other variables remain constant is the inability to cross the CTO lesion. This can be due to a failure to cross the lesion with a guide wire (despite guide wire escalation). The second cause of failure is the inability to cross the lesion with a balloon (balloon-uncrossable [BU] CTO). This can occur despite the successful placement of a guidewire in the distal true lumen. The BU lesions contribute 2% to 10% of CTO PCI failure cases. The author attempts to present a creative solution to assist crossing such lesions. PMID:29625510

  18. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  19. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  20. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  1. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  2. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  3. Guided wave opto-acoustic device

    DOEpatents

    Jarecki, Jr., Robert L.; Rakich, Peter Thomas; Camacho, Ryan; Shin, Heedeuk; Cox, Jonathan Albert; Qiu, Wenjun; Wang, Zheng

    2016-02-23

    The various technologies presented herein relate to various hybrid phononic-photonic waveguide structures that can exhibit nonlinear behavior associated with traveling-wave forward stimulated Brillouin scattering (forward-SBS). The various structures can simultaneously guide photons and phonons in a suspended membrane. By utilizing a suspended membrane, a substrate pathway can be eliminated for loss of phonons that suppresses SBS in conventional silicon-on-insulator (SOI) waveguides. Consequently, forward-SBS nonlinear susceptibilities are achievable at about 3000 times greater than achievable with a conventional waveguide system. Owing to the strong phonon-photon coupling achievable with the various embodiments, potential application for the various embodiments presented herein cover a range of radiofrequency (RF) and photonic signal processing applications. Further, the various embodiments presented herein are applicable to applications operating over a wide bandwidth, e.g. 100 MHz to 50 GHz or more.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iguchi, Toshihiro, E-mail: iguchi@ba2.so-net.ne.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp

    PurposeThe aim of the study was to retrospectively evaluate simultaneous multiple hook wire placement outcomes before video-assisted thoracoscopic surgery (VATS).Materials and MethodsThirty-eight procedures were performed on 35 patients (13 men and 22 women; mean age, 59.9 years) with 80 lung lesions (mean diameter 7.9 mm) who underwent simultaneous multiple hook wire placements for preoperative localizations. The primary endpoints were technical success, complications, procedure duration, and VATS outcome; secondary endpoints included comparisons between technical success rates, complication rates, and procedure durations of the 238 single-placement procedures performed. Complications were also evaluated.ResultsIn 35 procedures including 74 lesions, multiple hook wire placements were technically successful;more » in the remaining three procedures, the second target placement was aborted because of massive pneumothorax after the first placement. Although complications occurred in 34 procedures, no grade 3 or above adverse event was observed. The mean procedure duration was 36.4 ± 11.8 min. Three hook wires dislodged during patient transport to the surgical suite. Seventy-four successfully marked lesions were resected. Six lesions without hook wires were successfully resected after detection by palpation with an additional mini-thoracotomy or using subtle pleural changes as a guide. The complication rates and procedure durations of multiple-placement procedures were significantly higher (P = 0.04) and longer (P < 0.001) than those in the single-placement group, respectively, while the technical success rate was not significantly different (P = 0.051).ConclusionsSimultaneous multiple hook wire placements before VATS were clinically feasible, but increased the complication rate and lengthened the procedure time.« less

  5. Neoinfundibulotomy for the management of symptomatic caliceal diverticula.

    PubMed

    Auge, Brian K; Munver, Ravi; Kourambas, John; Newman, Glenn E; Wu, Ning Z; Preminger, Glenn M

    2002-04-01

    Direct percutaneous access provides effective treatment for complex caliceal diverticula. Yet, access into the diverticulum alone is usually tenuous and passage of a guide wire across a stenotic infundibulum is often impossible. An alternative technique is described which creates a "neoinfundibulum" to assist in the management of symptomatic caliceal diverticula. During a 6-year period 22 patients with symptomatic caliceal diverticula were treated via a percutaneous approach, of whom 21 had calculi within the diverticula. After accessing the diverticulum directly, it was impossible to pass a guide wire through the stenotic infundibulum in 18 (82%) patients, prompting advancement of the access needle through the diverticular wall into the renal pelvis. Once secure access was established, balloon dilation was performed to 30Fr to create the "neoinfundibulum." Percutaneous ultrasonic lithotripsy was performed in the usual fashion. A 22Fr Councill catheter was placed to keep the infundibular tract open for 5 to 7 days to allow complete epithelialization and drainage. Stone-free, symptom-free and complication rates were assessed. Pain, recurrent urinary tract infections and hematuria were the presenting complaints in the subgroup of patients undergoing "neoinfundibulotomy." Average stone burden was 11.7 x 12 mm. and average hospital stay was 2.8 days. Of the patients 94% were symptom-free at 6-week followup, and 80% were stone-free on followup excretory urography. The remaining patients had residual stone fragments less than 3 mm. in diameter. Complications related to access were identified in 2 patients who sustained a pneumothorax after a supra-11th rib access, which was successfully managed with tube thoracostomy. Percutaneous management of complex caliceal diverticula provides a safe and effective option for symptomatic patients. When the stenotic infundibulum cannot be traversed with a guide wire, creation of a new infundibulum offers a secure alternative for accessing the collecting system, while providing equally effective results.

  6. Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control.

    PubMed

    Philadelpho Arantes Pereira, Fernanda; Martins, Gabriela; Gregorio Calas, Maria Julia; Fonseca Torres de Oliveira, Maria Veronica; Gasparetto, Emerson Leandro; Barbosa da Fonseca, Lea Mirian

    2013-09-18

    Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure's positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). MRI-ROLL offers a precise, technically feasible, safe, and rapid means for performing preoperative MRI localizations in the breast.

  7. 47 CFR 2.801 - Radiofrequency device defined.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency device defined. 2.801 Section 2... MATTERS; GENERAL RULES AND REGULATIONS Marketing of Radio-frequency Devices § 2.801 Radiofrequency device defined. As used in this part, a radiofrequency device is any device which in its operation is capable of...

  8. Pulse-dose radiofrequency treatment in pain management-initial experience.

    PubMed

    Ojango, Christine; Raguso, Mario; Fiori, Roberto; Masala, Salvatore

    2018-05-01

    Radiofrequency procedures have been used for treating various chronic pain conditions for decades. These minimally invasive percutaneous treatments employ an alternating electrical current with oscillating radiofrequency wavelengths to eliminate or alter pain signals from the targeted site. The aim of the continuous radiofrequency procedure is to increase the temperature sufficiently to create an irreversible thermal lesion on nerve fibres and thus permanently interrupt pain signals. The pulsed radiofrequency procedure utilises short pulses of radiofrequency current with intervals of longer pauses to avert a temperature increase to the level of permanent tissue damage. The goal of these pulses is to alter the processing of pain signals, but to avoid relevant structural damage to nerve fibres, as seen in the continuous radiofrequency procedure. The pulse-dose radiofrequency procedure is a technical improvement of the pulsed radiofrequency technique in which the delivery mode of the current is adapted. During the pulse-dose radiofrequency procedure thermal damage is avoided. In addition, the amplitude and width of the consecutive pulses are kept the same. The method ensures that each delivered pulse keeps the same characteristics and therefore the dose is similar between patients. The current review outlines the pulse-dose radiofrequency procedure and presents our institution's chronic pain management studies.

  9. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions

    PubMed Central

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-01-01

    Patient: Male, 69 Final Diagnosis: Atherosclerotic renal artery stenosis Symptoms: None Medication: — Clinical Procedure: — Specialty: Radiology Objective: Unusual setting of medical care Background: The GuideLiner catheter extension device is a monorail-type “Child” support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). Case Report: We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guide-wires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. Conclusions: The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion. PMID:28533503

  10. Synaptogenesis in the CNS: An Odyssey from Wiring Together to Firing Together

    PubMed Central

    Munno, David W; Syed, Naweed I

    2003-01-01

    To acquire a better comprehension of nervous system function, it is imperative to understand how synapses are assembled during development and subsequently altered throughout life. Despite recent advances in the fields of neurodevelopment and synaptic plasticity, relatively little is known about the mechanisms that guide synapse formation in the central nervous system (CNS). Although many structural components of the synaptic machinery are pre-assembled prior to the arrival of growth cones at the site of their potential targets, innumerable changes, central to the proper wiring of the brain, must subsequently take place through contact-mediated cell-cell communications. Identification of such signalling molecules and a characterization of various events underlying synaptogenesis are pivotal to our understanding of how a brain cell completes its odyssey from ‘wiring together to firing together’. Here we attempt to provide a comprehensive overview that pertains directly to the cellular and molecular mechanisms of selection, formation and refinement of synapses during the development of the CNS in both vertebrates and invertebrates. PMID:12897180

  11. Lesion guided stereotactic radiofrequency thermocoagulation for palliative, in selected cases curative epilepsy surgery.

    PubMed

    Wellmer, Jörg; Parpaley, Yaroslav; Rampp, Stefan; Popkirov, Stoyan; Kugel, Harald; Aydin, Ümit; Wolters, Carsten H; von Lehe, Marec; Voges, Jürgen

    2016-03-01

    Resective epilepsy surgery is an established treatment option in patients with pharmacoresistant, lesion related epilepsy. Yet, if the presurgical work-up proves multi-focal organization of the epileptogenic zone, or the area of intended resection is close to eloquent brain areas, patients may decide against resections because of an unfavorable risk-benefit-ratio. We assess if lesion guided cortical stereotactic radiofrequency thermocoagulation (L-RFTC) is a potential surgical alternative in these patients. We performed seven procedures of L-RFTC. Three patients had monofocal epilepsy arising close to eloquent structures; in four, invasive pre-surgical workup documented monofocal seizure onset but strong interictal epileptic activity also independent and distant from the seizure onset zone. L-RFTC was restricted to the lesional area (=seizure onset site). 12 to 37 months after RFTC worthwhile seizure improvement was achieved in 6 patients. One patient became seizure free following complete coagulation of a focal cortical dysplasia, two had had 1-2 auras under tapered but not under continued medication. In one patient only subclinical seizures persisted. In one patient hypermotor seizures were transformed into milder short tonic seizures and another one had a seizure reduction by 50%. Only one patient did not profit at all. One patient developed a persisting neurological deficit. In patients with complex epileptogenic zones L-RFTC can lead to worthwhile seizure reduction. This qualifies this procedure as a palliative surgical technique with potential good risk-benefit ratio. In patients with small focal cortical dysplasias L-RFTC may even allow minimal-invasive surgery with curative intention. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Comparison of renal artery, soft tissue, and nerve damage after irrigated versus nonirrigated radiofrequency ablation.

    PubMed

    Sakakura, Kenichi; Ladich, Elena; Fuimaono, Kristine; Grunewald, Debby; O'Fallon, Patrick; Spognardi, Anna-Maria; Markham, Peter; Otsuka, Fumiyuki; Yahagi, Kazuyuki; Shen, Kai; Kolodgie, Frank D; Joner, Michael; Virmani, Renu

    2015-01-01

    The long-term efficacy of radiofrequency ablation of renal autonomic nerves has been proven in nonrandomized studies. However, long-term safety of the renal artery (RA) is of concern. The aim of our study was to determine if cooling during radiofrequency ablation preserved the RA while allowing equivalent nerve damage. A total of 9 swine (18 RAs) were included, and allocated to irrigated radiofrequency (n=6 RAs, temperature setting: 50°C), conventional radiofrequency (n=6 RAs, nonirrigated, temperature setting: 65°C), and high-temperature radiofrequency (n=6 RAs, nonirrigated, temperature setting: 90°C) groups. RAs were harvested at 10 days, serially sectioned from proximal to distal including perirenal tissues and examined after paraffin embedding, and staining with hematoxylin-eosin and Movat pentachrome. RAs and periarterial tissue including nerves were semiquantitatively assessed and scored. A total of 660 histological sections from 18 RAs were histologically examined by light microscopy. Arterial medial injury was significantly less in the irrigated radiofrequency group (depth of medial injury, circumferential involvement, and thinning) than that in the conventional radiofrequency group (P<0.001 for circumference; P=0.003 for thinning). Severe collagen damage such as denatured collagen was also significantly less in the irrigated compared with the conventional radiofrequency group (P<0.001). Nerve damage although not statistically different between the irrigated radiofrequency group and conventional radiofrequency group (P=0.36), there was a trend toward less nerve damage in the irrigated compared with conventional. Compared to conventional radiofrequency, circumferential medial damage in highest-temperature nonirrigated radiofrequency group was significantly greater (P<0.001). Saline irrigation significantly reduces arterial and periarterial tissue damage during radiofrequency ablation, and there is a trend toward less nerve damage. © 2014 American Heart Association, Inc.

  13. K.s. Micro-implant placement guide.

    PubMed

    Sharma, K; Sangwan, A

    2014-09-01

    A one of the greatest concerns with orthodontic mini-implants is risk of injury to dental roots during placement is, especially when they are inserted between teeth. Many techniques have been used to facilitate safe placement of interradicular miniscrews. Brass Wires or metallic markers are easy to place in the interproximal spaces, but because their relative positions may be inconsistent in different radio -graphic views, they are not always accurate. K.S. micro implant placement guide suggested in this article is simple design and easy in fabrication, required minimal equipment for fabrication and does not disturb the existing appliance system, clearly located in the radiograph and the mini-screw can be easily inserted through the guide reducing the chance of implant misplacement.

  14. First-in-Man Computed Tomography-Guided Percutaneous Revascularization of Coronary Chronic Total Occlusion Using a Wearable Computer: Proof of Concept.

    PubMed

    Opolski, Maksymilian P; Debski, Artur; Borucki, Bartosz A; Szpak, Marcin; Staruch, Adam D; Kepka, Cezary; Witkowski, Adam

    2016-06-01

    We report a case of successful computed tomography-guided percutaneous revascularization of a chronically occluded right coronary artery using a wearable, hands-free computer with a head-mounted display worn by interventional cardiologists in the catheterization laboratory. The projection of 3-dimensional computed tomographic reconstructions onto the screen of virtual reality glass allowed the operators to clearly visualize the distal coronary vessel, and verify the direction of the guide wire advancement relative to the course of the occluded vessel segment. This case provides proof of concept that wearable computers can improve operator comfort and procedure efficiency in interventional cardiology. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  15. 50 CFR 218.20 - Specified activity and specified geographical area and effective dates.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (Hellfire missile); (B) Tube-launched Optically tracked Wire-guided (TOW) missile; (C) Mine Neutralization... NEW charges)—up to 100 exercises over the course of 5 years (an average of 20 per year); (B) Missile Exercise (MISSILEX) (Air-to-Surface; Hellfire missile)—up to 40 exercises over the course of 5 years (an...

  16. 50 CFR 218.20 - Specified activity and specified geographical area and effective dates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Explosives: (A) AGM-114 (Hellfire missile); (B) Tube-launched Optically tracked Wire-guided (TOW) missile; (C...) Missile Exercise (MISSILEX) (Air-to-Surface; Hellfire missile)—up to 40 exercises over the course of 5 years (an average of 8 per year); (C) Missile Exercise (MISSILEX) (Air-to-Surface; TOW)—up to 40...

  17. 50 CFR 218.20 - Specified activity and specified geographical area and effective dates.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Explosives: (A) AGM-114 (Hellfire missile); (B) Tube-launched Optically tracked Wire-guided (TOW) missile; (C...) Missile Exercise (MISSILEX) (Air-to-Surface; Hellfire missile)—up to 40 exercises over the course of 5 years (an average of 8 per year); (C) Missile Exercise (MISSILEX) (Air-to-Surface; TOW)—up to 40...

  18. 50 CFR 218.20 - Specified activity and specified geographical area and effective dates.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (Hellfire missile); (B) Tube-launched Optically tracked Wire-guided (TOW) missile; (C) Mine Neutralization... NEW charges)—up to 100 exercises over the course of 5 years (an average of 20 per year); (B) Missile Exercise (MISSILEX) (Air-to-Surface; Hellfire missile)—up to 40 exercises over the course of 5 years (an...

  19. The Department of Defense Very High Speed Integrated Circuit (VHSIC) Technology Availability Program Plan for the Committees on Armed Services United States Congress.

    DTIC Science & Technology

    1986-06-30

    features of computer aided design systems and statistical quality control procedures that are generic to chip sets and processes. RADIATION HARDNESS -The...System PSP Programmable Signal Processor SSI Small Scale Integration ." TOW Tube Launched, Optically Tracked, Wire Guided TTL Transistor Transitor Logic

  20. Radiofrequency Thermal Ablation Heat Energy Transfer in an Ex-Vivo Model.

    PubMed

    Thakur, Shivani; Lavito, Sandi; Grobner, Elizabeth; Grobner, Mark

    2017-12-01

    Little work has been done to consider the temperature changes and energy transfer that occur in the tissue outside the vein with ultrasound-guided vein ablation therapy. In this experiment, a Ex-Vivo model of the human calf was used to analyze heat transfer and energy degradation in tissue surrounding the vein during endovascular radiofrequency ablation (RFA). A clinical vein ablation protocol was used to determine the tissue temperature distribution in 10 per cent agar gel. Heat energy from the radiofrequency catheter was measured for 140 seconds at fixed points by four thermometer probes placed equidistant radially at 0.0025, 0.005, and 0.01 m away from the RFA catheter. The temperature rose 1.5°C at 0.0025 m, 0.6°C at 0.005 m, and 0.0°C at 0.01 m from the RFA catheter. There was a clinically insignificant heat transfer at the distances evaluated, 1.4 ± 0.2 J/s at 0.0025 m, 0.7 ± 0.3 J/s at 0.0050 m, and 0.3 ± 0.0 J/s at 0.01 m. Heat degradation occurred rapidly: 4.5 ± 0.5 J (at 0.0025 m), 4.0 ± 1.6 J (at 0.0050 m), and 3.9 ± 3.6 J (at 0.01 m). Tumescent anesthesia injected one centimeter around the vein would act as a heat sink to absorb the energy transferred outside the vein to minimize tissue and nerve damage and will help phlebologists strategize options for minimizing damage.

  1. A prospective development study of software-guided radio-frequency ablation of primary and secondary liver tumors: Clinical intervention modelling, planning and proof for ablation cancer treatment (ClinicIMPPACT).

    PubMed

    Reinhardt, Martin; Brandmaier, Philipp; Seider, Daniel; Kolesnik, Marina; Jenniskens, Sjoerd; Sequeiros, Roberto Blanco; Eibisberger, Martin; Voglreiter, Philip; Flanagan, Ronan; Mariappan, Panchatcharam; Busse, Harald; Moche, Michael

    2017-12-01

    Radio-frequency ablation (RFA) is a promising minimal-invasive treatment option for early liver cancer, however monitoring or predicting the size of the resulting tissue necrosis during the RFA-procedure is a challenging task, potentially resulting in a significant rate of under- or over treatments. Currently there is no reliable lesion size prediction method commercially available. ClinicIMPPACT is designed as multicenter-, prospective-, non-randomized clinical trial to evaluate the accuracy and efficiency of innovative planning and simulation software. 60 patients with early liver cancer will be included at four European clinical institutions and treated with the same RFA system. The preinterventional imaging datasets will be used for computational planning of the RFA treatment. All ablations will be simulated simultaneously to the actual RFA procedure, using the software environment developed in this project. The primary outcome measure is the comparison of the simulated ablation zones with the true lesions shown in follow-up imaging after one month, to assess accuracy of the lesion prediction. This unique multicenter clinical trial aims at the clinical integration of a dedicated software solution to accurately predict lesion size and shape after radiofrequency ablation of liver tumors. Accelerated and optimized workflow integration, and real-time intraoperative image processing, as well as inclusion of patient specific information, e.g. organ perfusion and registration of the real RFA needle position might make the introduced software a powerful tool for interventional radiologists to optimize patient outcomes.

  2. CEM43°C thermal dose thresholds: a potential guide for magnetic resonance radiofrequency exposure levels?

    PubMed

    van Rhoon, Gerard C; Samaras, Theodoros; Yarmolenko, Pavel S; Dewhirst, Mark W; Neufeld, Esra; Kuster, Niels

    2013-08-01

    To define thresholds of safe local temperature increases for MR equipment that exposes patients to radiofrequency fields of high intensities for long duration. These MR systems induce heterogeneous energy absorption patterns inside the body and can create localised hotspots with a risk of overheating. The MRI + EUREKA research consortium organised a "Thermal Workshop on RF Hotspots". The available literature on thresholds for thermal damage and the validity of the thermal dose (TD) model were discussed. The following global TD threshold guidelines for safe use of MR are proposed: 1. All persons: maximum local temperature of any tissue limited to 39 °C 2. Persons with compromised thermoregulation AND (a) Uncontrolled conditions: maximum local temperature limited to 39 °C (b) Controlled conditions: TD < 2 CEM43°C 3. Persons with uncompromised thermoregulation AND (a) Uncontrolled conditions: TD < 2 CEM43°C (b) Controlled conditions: TD < 9 CEM43°C The following definitions are applied: Controlled conditions A medical doctor or a dedicated trained person can respond instantly to heat-induced physiological stress Compromised thermoregulation All persons with impaired systemic or reduced local thermoregulation • Standard MRI can cause local heating by radiofrequency absorption. • Monitoring thermal dose (in units of CEM43°C) can control risk during MRI. • 9 CEM43°C seems an acceptable thermal dose threshold for most patients. • For skin, muscle, fat and bone,16 CEM43°C is likely acceptable.

  3. Wirelessly powered microfluidic dielectrophoresis devices using printable RF circuits.

    PubMed

    Qiao, Wen; Cho, Gyoujin; Lo, Yu-Hwa

    2011-03-21

    We report the first microfluidic device integrated with a printed RF circuit so the device can be wirelessly powered by a commercially available RFID reader. For conventional dielectrophoresis devices, electrical wires are needed to connect the electric components on the microchip to external equipment such as power supplies, amplifiers, function generators, etc. Such a procedure is unfamiliar to most clinicians and pathologists who are used to working with a microscope for examination of samples on microscope slides. The wirelessly powered device reported here eliminates the entire need for wire attachments and external instruments so the operators can use the device in essentially the same manner as they do with microscope slides. The integrated circuit can be fabricated on a flexible plastic substrate at very low cost using a roll-to-roll printing method. Electrical power at 13.56 MHz transmitted by a radio-frequency identification (RFID) reader is inductively coupled to the printed RFIC and converted into 10 V DC (direct current) output, which provides sufficient power to drive a microfluidic device to manipulate biological particles such as beads and proteins via the DC dielectrophoresis (DC-DEP) effect. To our best knowledge, this is the first wirelessly powered microfluidic dielectrophoresis device. Although the work is preliminary, the device concept, the architecture, and the core technology are expected to stimulate many efforts in the future and transform the technology to a wide range of clinical and point-of-care applications. This journal is © The Royal Society of Chemistry 2011

  4. Pulsed Dose Radiofrequency Before Ablation of Medial Branch of the Lumbar Dorsal Ramus for Zygapophyseal Joint Pain Reduces Post-procedural Pain.

    PubMed

    Arsanious, David; Gage, Emmanuel; Koning, Jonathon; Sarhan, Mazin; Chaiban, Gassan; Almualim, Mohammed; Atallah, Joseph

    2016-01-01

    One of the potential side effects with radiofrequency ablation (RFA) includes painful cutaneous dysesthesias and increased pain due to neuritis or neurogenic inflammation. This pain may require the prescription of opioids or non-opioid analgesics to control post-procedural pain and discomfort. The goal of this study is to compare post-procedural pain scores and post-procedural oral analgesic use in patients receiving continuous thermal radiofrequency ablation versus patients receiving pulsed dose radiofrequency immediately followed by continuous thermal radiofrequency ablation for zygopophaseal joint disease. This is a prospective, double-blinded, randomized, controlled trial. Patients who met all the inclusion criteria and were not subject to any of the exclusion criteria were required to have two positive diagnostic medial branch blocks prior to undergoing randomization, intervention, and analysis. University hospital. Eligible patients were randomized in a 1:1 ratio to either receive thermal radiofrequency ablation alone (standard group) or pulsed dose radiofrequency (PDRF) immediately followed by thermal radiofrequency ablation (investigational group), all of which were performed by a single Board Certified Pain Medicine physician. Post-procedural pain levels between the two groups were assessed using the numerical pain Scale (NPS), and patients were contacted by phone on post-procedural days 1 and 2 in the morning and afternoon regarding the amount of oral analgesic medications used in the first 48 hours following the procedure. Patients who received pulsed dose radiofrequency followed by continuous radiofrequency neurotomy reported statistically significantly lower post-procedural pain scores in the first 24 hours compared to patients who received thermal radiofrequency neurotomy alone. These patients also used less oral analgesic medication in the post-procedural period. These interventions were carried out by one board accredited pain physician at one center. The procedures were exclusively performed using one model of radiofrequency generator, at one setting for the PDRF and RFA. The difference in the number of levels of ablation was not considered in the analysis of the results. Treating patients with pulsed dose radiofrequency prior to continuous thermal radiofrequency ablation can provide patients with less post-procedural pain during the first 24 hours and also reduce analgesic requirements. Furthermore, the addition of PDRF to standard thermal RFA did not prolong the time of standard thermal radiofrequency ablation procedures, as it was performed during the typically allotted time for local anesthetic action. Low back pain, facet joint disease, medial branch block, Radiofrequency ablation, thermal radiofrequency, pulsed dose radiofrequency, PDRF, zygapophyseal joint.

  5. A practical guide to the design and construction of a single wire beverage antenna

    NASA Astrophysics Data System (ADS)

    Spong, H. L.

    1980-09-01

    Theoretical results are presented which show the performance likely to result from using differing antenna heights, lengths and wire sizes and from operating with different ground conductivities. These studies were undertaken to provide practical advice for constructors and operators. Design parameters can be easily obtained with the aid of computer programs and an antenna can be rapidly constructed from readily available materials. Directivity can be increased by adding more elements, either in parallel or on a radial basis. A particular performance can be achieved with great latitude in the parameters. Good low angle performance can be achieved without large ground screens. A directional array can be made by switching between a number of elements set up on different bearings.

  6. Limits of Kirchhoff's Laws in Plasmonics.

    PubMed

    Razinskas, Gary; Biagioni, Paolo; Hecht, Bert

    2018-01-30

    The validity of Kirchhoff's laws in plasmonic nanocircuitry is investigated by studying a junction of plasmonic two-wire transmission lines. We find that Kirchhoff's laws are valid for sufficiently small values of a phenomenological parameter κ relating the geometrical parameters of the transmission line with the effective wavelength of the guided mode. Beyond such regime, for large values of the phenomenological parameter, increasing deviations occur and the equivalent impedance description (Kirchhoff's laws) can only provide rough, but nevertheless useful, guidelines for the design of more complex plasmonic circuitry. As an example we investigate a system composed of a two-wire transmission line and a nanoantenna as the load. By addition of a parallel stub designed according to Kirchhoff's laws we achieve maximum signal transfer to the nanoantenna.

  7. 47 CFR 2.807 - Statutory exceptions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Carriers transporting radiofrequency devices without trading in them. (b) Radiofrequency devices manufactured solely for export. (c) The manufacture, assembly, or installation of radiofrequency devices for... device shall be operated if it causes harmful interference to radio communications. (d) Radiofrequency...

  8. Radioguided localisation of impalpable breast lesions using 99m-Technetium macroaggregated albumin: Lessons learnt during introduction of a new technique to guide preoperative localisation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landman, Joanne; Kulawansa, Sagarika; McCarthy, Michael

    2015-03-15

    Preoperative wire-guided localisation (WGL) of impalpable breast lesions is widely used but can be technically difficult. Risks include wire migration, inaccurate placement, and inadequate surgical margins. Research shows that radioguided occult lesion localisation (ROLL) is quicker, easier, and can improve surgical and cosmetic outcomes. An audited introduction of ROLL was conducted to validate the technique as a feasible alternative to WGL. Fifty patients with single impalpable lesions and biopsy proven malignancy or indeterminate histology underwent WGL followed by intralesional radiopharmaceutical injection of 99m-Technetium macroaggregated albumin. Postprocedural mammography was performed to demonstrate wire position, and scintigraphy to evaluate radiopharmaceutical migration. Lymphoscintigraphymore » and intraoperative sentinel node biopsy were performed if indicated, followed by lesion localisation and excision using a gamma probe. Specimen imaging was performed, with immediate reexcision for visibly inadequate margins. Accurate localisation was achieved in 86% of patients with ROLL compared to 72% with WGL. All lesions were successfully removed, with clear margins in 71.8% of malignant lesions. Reexcision and intraoperative sentinel node localisation rates were equivalent to preaudit figures for WGL. ROLL was easy to perform and problems were infrequent. Inaccurate radiopharmaceutical placement necessitating WGL occurred in four patients. Minor radiopharmaceutical migration was common, but precluded using ROLL in only two cases. ROLL is effective, simple, inexpensive, and easily learnt; however, preoperative confirmation of correct radiopharmaceutical placement using mammography and the gamma probe is important to help ensure successful lesion removal. Insertion of a backup hookwire is recommended during the initial introduction of ROLL.« less

  9. Improved 3D live-wire method with application to 3D CT chest image analysis

    NASA Astrophysics Data System (ADS)

    Lu, Kongkuo; Higgins, William E.

    2006-03-01

    The definition of regions of interests (ROIs), such as suspect cancer nodules or lymph nodes in 3D CT chest images, is often difficult because of the complexity of the phenomena that give rise to them. Manual slice tracing has been used widely for years for such problems, because it is easy to implement and guaranteed to work. But the manual method is extremely time-consuming, especially for high-solution 3D images which may have hundreds of slices, and it is subject to operator biases. Numerous automated image-segmentation methods have been proposed, but they are generally strongly application dependent, and even the "most robust" methods have difficulty in defining complex anatomical ROIs. To address this problem, the semi-automatic interactive paradigm referred to as "live wire" segmentation has been proposed by researchers. In live-wire segmentation, the human operator interactively defines an ROI's boundary guided by an active automated method which suggests what to define. This process in general is far faster, more reproducible and accurate than manual tracing, while, at the same time, permitting the definition of complex ROIs having ill-defined boundaries. We propose a 2D live-wire method employing an improved cost over previous works. In addition, we define a new 3D live-wire formulation that enables rapid definition of 3D ROIs. The method only requires the human operator to consider a few slices in general. Experimental results indicate that the new 2D and 3D live-wire approaches are efficient, allow for high reproducibility, and are reliable for 2D and 3D object segmentation.

  10. A Comparison of Zero Mean Strain Rotating Beam Fatigue Test Methods for Nitinol Wire

    NASA Astrophysics Data System (ADS)

    Norwich, Dennis W.

    2014-07-01

    Zero mean strain rotating beam fatigue testing has become the standard for comparing the fatigue properties of Nitinol wire. Most commercially available equipment consists of either a two-chuck or a chuck and bushing system, where the wire length and center-to-center axis distance determine the maximum strain on the wire. For the two-chuck system, the samples are constrained at either end of the wire, and both chucks are driven at the same speed. For the chuck and bushing system, the sample is constrained at one end in a chuck and rides freely in a bushing at the other end. These equivalent systems will both be herein referred to as Chuck-to-Chuck systems. An alternate system uses a machined test block with a specific radius to guide the wire at a known strain during testing. In either system, the test parts can be immersed in a temperature-controlled fluid bath to eliminate any heating effect created in the specimen due to dissipative processes during cyclic loading (cyclic stress induced the formation of martensite) Wagner et al. ( Mater. Sci. Eng. A, 378, p 105-109, 1). This study will compare the results of the same starting material tested with each system to determine if the test system differences affect the final results. The advantages and disadvantages of each system will be highlighted and compared. The factors compared will include ease of setup, operator skill level required, consistency of strain measurement, equipment test limits, and data recovery and analysis. Also, the effect of test speed on the test results for each system will be investigated.

  11. Minimally invasive guidewireless, navigated pedicle screw placement: a technical report and case series.

    PubMed

    Smith, Brandon W; Joseph, Jacob R; Kirsch, Michael; Strasser, Mary Oakley; Smith, Jacob; Park, Paul

    2017-08-01

    OBJECTIVE Percutaneous pedicle screw insertion (PPSI) is a mainstay of minimally invasive spinal surgery. Traditionally, PPSI is a fluoroscopy-guided, multistep process involving traversing the pedicle with a Jamshidi needle, placement of a Kirschner wire (K-wire), placement of a soft-tissue dilator, pedicle tract tapping, and screw insertion over the K-wire. This study evaluates the accuracy and safety of PPSI with a simplified 2-step process using a navigated awl-tap followed by navigated screw insertion without use of a K-wire or fluoroscopy. METHODS Patients undergoing PPSI utilizing the K-wire-less technique were identified. Data were extracted from the electronic medical record. Complications associated with screw placement were recorded. Postoperative radiographs as well as CT were evaluated for accuracy of pedicle screw placement. RESULTS Thirty-six patients (18 male and 18 female) were included. The patients' mean age was 60.4 years (range 23.8-78.4 years), and their mean body mass index was 28.5 kg/m 2 (range 20.8-40.1 kg/m 2 ). A total of 238 pedicle screws were placed. A mean of 6.6 pedicle screws (range 4-14) were placed over a mean of 2.61 levels (range 1-7). No pedicle breaches were identified on review of postoperative radiographs. In a subgroup analysis of the 25 cases (69%) in which CT scans were performed, 173 screws were assessed; 170 (98.3%) were found to be completely within the pedicle, and 3 (1.7%) demonstrated medial breaches of less than 2 mm (Grade B). There were no complications related to PPSI in this cohort. CONCLUSIONS This streamlined 2-step K-wire-less, navigated PPSI appears safe and accurate and avoids the need for radiation exposure to surgeon and staff.

  12. Brachial Plexus Injury from CT-Guided RF Ablation Under General Anesthesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shankar, Sridhar, E-mail: shankars@ummhc.org; Sonnenberg, Eric van; Silverman, Stuart G.

    2005-06-15

    Brachial plexus injury in a patient under general anesthesia (GA) is not uncommon, despite careful positioning and, particularly, awareness of the possibility. The mechanism of injury is stretching and compression of the brachial plexus over a prolonged period. Positioning the patient within the computed tomography (CT) gantry for abdominal or chest procedures can simulate a surgical procedure, particularly when GA is used. The potential for brachial plexus injury is increased if the case is prolonged and the patient's arms are raised above the head to avoid CT image degradation from streak artifacts. We report a case of profound brachial plexusmore » palsy following a CT-guided radiofrequency ablation procedure under GA. Fortunately, the patient recovered completely. We emphasize the mechanism of injury and detail measures to combat this problem, such that radiologists are aware of this potentially serious complication.« less

  13. A cycloidal wobble motor driven by shape memory alloy wires

    NASA Astrophysics Data System (ADS)

    Hwang, Donghyun; Higuchi, Toshiro

    2014-05-01

    A cycloidal wobble motor driven by shape memory alloy (SMA) wires is proposed. In realizing a motor driving mechanism well known as a type of reduction system, a cycloidal gear mechanism is utilized. It facilitates the achievement of bidirectional continuous rotation with high-torque capability, based on its high efficiency and high reduction ratio. The applied driving mechanism consists of a pin/roller based annular gear as a wobbler, a cycloidal disc as a rotor, and crankshafts to guide the eccentric wobbling motion. The wobbling motion of the annular gear is generated by sequential activation of radially phase-symmetrically placed SMA wires. Consequently the cycloidal disc is rotated by rolling contact based cycloidal gearing between the wobbler and the rotor. In designing the proposed motor, thermomechanical characterization of an SMA wire biased by extension springs is experimentally performed. Then, a simplified geometric model for the motor is devised to conduct theoretical assessment of design parametric effects on structural features and working performance. With consideration of the results from parametric analysis, a functional prototype three-phase motor is fabricated to carry out experimental verification of working performance. The observed experimental results including output torque, rotational speed, bidirectional positioning characteristic, etc obviously demonstrate the practical applicability and potentiality of the wobble motor.

  14. Using Ant Colony Optimization for Routing in VLSI Chips

    NASA Astrophysics Data System (ADS)

    Arora, Tamanna; Moses, Melanie

    2009-04-01

    Rapid advances in VLSI technology have increased the number of transistors that fit on a single chip to about two billion. A frequent problem in the design of such high performance and high density VLSI layouts is that of routing wires that connect such large numbers of components. Most wire-routing problems are computationally hard. The quality of any routing algorithm is judged by the extent to which it satisfies routing constraints and design objectives. Some of the broader design objectives include minimizing total routed wire length, and minimizing total capacitance induced in the chip, both of which serve to minimize power consumed by the chip. Ant Colony Optimization algorithms (ACO) provide a multi-agent framework for combinatorial optimization by combining memory, stochastic decision and strategies of collective and distributed learning by ant-like agents. This paper applies ACO to the NP-hard problem of finding optimal routes for interconnect routing on VLSI chips. The constraints on interconnect routing are used by ants as heuristics which guide their search process. We found that ACO algorithms were able to successfully incorporate multiple constraints and route interconnects on suite of benchmark chips. On an average, the algorithm routed with total wire length 5.5% less than other established routing algorithms.

  15. Image-guided tumor ablation: standardization of terminology and reporting criteria.

    PubMed

    Goldberg, S Nahum; Grassi, Clement J; Cardella, John F; Charboneau, J William; Dodd, Gerald D; Dupuy, Damian E; Gervais, Debra; Gillams, Alice R; Kane, Robert A; Lee, Fred T; Livraghi, Tito; McGahan, John; Phillips, David A; Rhim, Hyunchul; Silverman, Stuart G

    2005-06-01

    The field of interventional oncology with use of image-guided tumor ablation requires standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison between treatments that use different technologies, such as chemical (ethanol or acetic acid) ablation, and thermal therapies, such as radiofrequency, laser, microwave, ultrasound, and cryoablation. This document provides a framework that will hopefully facilitate the clearest communication between investigators and will provide the greatest flexibility in comparison between the many new, exciting, and emerging technologies. An appropriate vehicle for reporting the various aspects of image-guided ablation therapy, including classification of therapies and procedure terms, appropriate descriptors of imaging guidance, and terminology to define imaging and pathologic findings, are outlined. Methods for standardizing the reporting of follow-up findings and complications and other important aspects that require attention when reporting clinical results are addressed. It is the group's intention that adherence to the recommendations will facilitate achievement of the group's main objective: improved precision and communication in this field that lead to more accurate comparison of technologies and results and, ultimately, to improved patient outcomes. Copyright RSNA, 2005.

  16. Predicting nurses' acceptance of radiofrequency identification technology.

    PubMed

    Norten, Adam

    2012-10-01

    The technology of radiofrequency identification allows for the scanning of radiofrequency identification-tagged objects and individuals without line-of-sight requirements. Healthcare organizations use radiofrequency identification to ensure the health and safety of patients and medical personnel and to uncover inefficiencies. Although the successful implementation of a system incorporating radiofrequency identification technologies requires acceptance and use of the technology, some nurses using radiofrequency identification in hospitals feel like "Big Brother" is watching them. This predictive study used a theoretical model assessing the effect of five independent variables: privacy concerns, attitudes, subjective norms, controllability, and self-efficacy, on a dependent variable, nurses' behavioral intention to use radiofrequency identification. A Web-based questionnaire containing previously validated questions was answered by 106 US RNs. Multiple linear regression showed that all constructs together accounted for 60% of the variance in nurses' intention to use radiofrequency identification. Of the predictors in the model, attitudes provided the largest unique contribution when the other predictors in the model were held constant; subjective norms also provided a unique contribution. Privacy concerns, controllability, and self-efficacy did not provide a significant contribution to nurses' behavioral intention to use radiofrequency identification.

  17. 78 FR 33633 - Human Exposure to Radiofrequency Electromagnetic Fields

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-04

    ..., and 15, et al. Human Exposure to Radiofrequency Electromagnetic Fields; Reassessment of Exposure to Radiofrequency Electromagnetic Fields Limits and Policies; Final Rule and Proposed Rule #0;#0;Federal Register... Radiofrequency Electromagnetic Fields AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY...

  18. ACIST-FFR Study (Assessment of Catheter-Based Interrogation and Standard Techniques for Fractional Flow Reserve Measurement)

    PubMed Central

    Chambers, Jeffrey W.; Seto, Arnold H.; Sarembock, Ian J.; Raveendran, Ganesh; Sakarovitch, Charlotte; Yang, Lingyao; Desai, Manisha; Jeremias, Allen; Price, Matthew J.

    2017-01-01

    Background— Measurement of fractional flow reserve (FFR) to guide coronary revascularization lags despite robust supportive data, partly because of the handling characteristics of traditional coronary pressure wires. An optical pressure-monitoring microcatheter, which can be advanced over a traditional coronary guidewire, facilitates FFR assessment but may underestimate pressure wire–derived FFR. Methods and Results— In this prospective, multicenter trial, 169 patients underwent FFR assessment with a pressure wire alone and with a pressure microcatheter over the pressure wire. An independent core laboratory performed quantitative coronary angiography and evaluated all pressure tracings. The primary end point was the bias or difference between the microcatheter FFR and the pressure wire FFR, as assessed by Bland–Altman analysis. The mean difference between the microcatheter and the pressure wire–derived FFR values was −0.022 (95% confidence interval, −0.029 to −0.015). On multivariable analysis, reference vessel diameter (P=0.027) and lesion length (P=0.044) were independent predictors of bias between the 2 FFR measurements. When the microcatheter FFR was added to this model, it was the only independent predictor of bias (P<0.001). The mean FFR value from the microcatheter was significantly lower than from the pressure wire (0.81 versus 0.83; P<0.001). In 3% of cases (95% confidence interval, 1.3%–6.7%), there was clinically meaningful diagnostic discordance, with the FFR from the pressure wire >0.80 and that from the microcatheter <0.75. These findings were similar when including all 210 patients with site-reported paired FFR data. Conclusions— An optical, pressure-monitoring microcatheter measures lower FFR compared with a pressure wire, but the diagnostic impact appears to be minimal in most cases. Clinical Trial Registration— URL: https://www.clinicaltrials.gov. Unique identifier: NCT02577484. PMID:29246917

  19. The feasibility and safety of applying the Magnetic Navigation System to manage chronically occluded vessels: a single centre experience.

    PubMed

    Ramcharitar, Steve; van der Giessen, Willem J; van der Ent, Martin; de Feyter, Pim; Serruys, Patrick W; van Geuns, Robert-Jan

    2011-01-01

    Applying the Magnetic Navigation System (MNS) to manage chronic total occlusions (CTOs). The MNS precisely directs a magnetised guidewire in vivo through two permanent external magnets. The first 43 consecutive MNS treated CTOs were retrospectively evaluated. Computed tomography coronary angiography (CTCA) co-integration with the MNS provided a virtual road map through the occlusion. Unsuccessful MNS cases were managed with bailout conventional guidewire techniques. Experienced CTO and MNS operators had unrestricted access to CTO devices and equipments. The MNS crossing success increased from 40% to 56% over 52 months and averaged 44.2% (19/43 patients). In 58.3% (14/24) of failed MNS cases the conventional wire approach was successful, giving an overall procedural success rate of 76.6%. Of those conventionally treated, two patients required pericardiocentesis. On average, 1.8 ± 0.9 stents (lengths 44.7 ± 21.4 mm and diameter 2.8 ± 0.4 mm) were implanted. Procedural times were lengthy (125.0 ± 35.3 min) requiring high fluoroscopy dosage (11980.2 ± 6457.9 Gy/cm2) and contrast media usage (388.8 ± 170.2 ml). Operators persevered less with magnetic wires (20.9 ± 12.4 min vs. 27.7 ± 24.4 min), and preferentially used the least stiff wire as first choice (53.5%). CTCA co-integration did not influence procedural outcome. As with conventional wires, higher magnetic wire successes occurred in low calcified lesions, those with a central stump and without bridging collaterals. In unselected CTOs, the magnetic wires are safe and feasible. Current modest success rates with a high procedural bailout rate implicate the need for improved magnetic guidewire technology comparable to available sophisticated conventional CTO wires. Randomised studies are needed to clarify the value of magnetic guided recanalisation.

  20. Military Applications of Fiber Optics Technology

    DTIC Science & Technology

    1989-05-01

    Research Projects Agency DNA Defense Nuclear Agency EMI Electromagnetic interference EMP Electromagnetic pulse FET Field effect transistor FOFA Follow...Organization SEED Self electro-optic effect device TBM Tactical ballistic missile TOW Tube launched, optically tracked, wire-guided UAV Unmanned aerial vehicle...systems, coupled with novel but effective transducing technology, have set the stage for a powerful class of fiber optic sensors. 8 Optical fibers have

  1. 78 FR 56655 - Foreign-Trade Zone (FTZ) 203-Moses Lake, Washington; Notification of Proposed Production Activity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-13

    ... choose the duty rate during customs entry procedures that applies to fuel rod assemblies (duty rate--3.3... plates; channels; spacers; end caps; springs; top and bottom nozzles; cages; guide tubes; and tubes, bar stocks, wires and plates of zirconium (duty rate ranges from 3.3 to 3.7%). Public comment is invited from...

  2. 21 CFR 882.4400 - Radiofrequency lesion generator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion generator. 882.4400 Section... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4400 Radiofrequency lesion generator. (a) Identification. A radiofrequency lesion generator is a device used to produce...

  3. Sigmoid irrigation tube for the management of chronic evacuation disorders.

    PubMed

    Gauderer, Michael W L; Decou, James M; Boyle, John T

    2002-03-01

    Antegrade colonic irrigation, in which the right colon is accessed via appendicostomy or cecostomy, now is an important adjunct in the management of children with chronic evacuation disorders. However, in most children, the major area of dysfunction is the left rather than the right colon. The authors developed a simple, percutaneous endoscopic, laparoscopically controlled sigmoid irrigation tube placement and evaluated the results in 4 children. A rigid sigmoidoscope is advanced into the upper sigmoid and the loop brought in contact with the abdominal wall under laparoscopic control. A small skin incision is made and a needle pushed across the abdominal and sigmoid walls into the lumen of the sigmoidoscope. A guide wire is advanced through the needle into the scope and retrieved. After the scope is removed, a PEG-type catheter is attached to the guide wire and pulled back, securing the sigmoid loop to the abdominal wall. The tube is subsequently converted to a skin-level device by simply adding an external port valve. All 4 patients achieved prompt evacuation in the sitting position. Sigmoid tube for antegrade irrigation is an appealing alternative to conventional cecal access. The procedure is simple and may offer physiologic advantages. Copyright 2002 by W.B. Saunders Company.

  4. Treatment efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation for benign thyroid nodules

    PubMed Central

    Li, Xiao-long; Lu, Feng; Yue, Wen-wen; Sun, Li-ping; Bo, Xiao-wan; Guo, Le-hang; Xu, Jun-mei; Liu, Bo-ji; Li, Dan-dan; Qu, Shen

    2016-01-01

    Objective: To evaluate the therapeutic efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation (BRFA) of benign thyroid nodules by comparison with a matched untreated control group. Methods: The therapeutic efficacy and safety in 35 patients who were subjected to a single session of ultrasound-guided percutaneous BRFA (Group A) for benign thyroid nodules were compared with those in 35 untreated patients (Group B) with benign nodules. The benign nature of all the nodules was confirmed by ultrasound-guided fine-needle aspiration biopsy (FNAB), and all the patients had normal thyroid functions. BRFA was performed with a bipolar electrode (CelonProSurge 150–T20) with an output power of 20 W. Nodule volume, thyroid function and clinical symptoms of all the patients were compared before treatment and during follow-up. Results: In Group A, the BRFA procedures were completed with a mean time of 10.02 ± 3.30 min (range, 5.47–16.03 min) and with a mean total energy deposition of 10.747 ± 3704 J (range, 5510–17.770 J). The procedures were tolerated well in all the patients without causing any major complications. At the 6-month follow-up, all of the nodule volume decreased significantly (from 8.81 ± 8.66 to 1.59 ± 1.55 ml, p < 0.001) in Group A, whereas the nodule volume increased from 6.90 ± 3.77 to 7.87 ± 3.95 ml in Group B (p < 0.001). All (100%) the 35 nodules in Group A had volume reduction ratios (VRRs) of >50%, among which 3 (8.57%) had VRRs >90%. In Group A, the clinical symptoms of the patients who had symptoms before BRFA disappeared, whereas in Group B, the patients had no resolution of clinical symptoms at the 6-month follow-up. Conclusion: Ultrasound-guided percutaneous BRFA seems to be an effective and safe method for the treatment of benign thyroid nodules. It may gain a wide use in clinical practice. Advances in knowledge: Based on the comparable efficacy and clinical symptoms between the BRFA and untreated groups, the technique of BRFA can be used as an effective and safe method for the treatment of benign thyroid nodules. PMID:26800232

  5. Transcervical, intrauterine ultrasound-guided radiofrequency ablation of uterine fibroids with the VizAblate® System: three- and six-month endpoint results from the FAST-EU study.

    PubMed

    Bongers, Marlies; Brölmann, Hans; Gupta, Janesh; Garza-Leal, José Gerardo; Toub, David

    This was a prospective, longitudinal, multicenter, single-arm controlled trial, using independent core laboratory validation of MRI results, to establish the effectiveness and confirm the safety of the VizAblate® System in the treatment of symptomatic uterine fibroids. The VizAblate System is a transcervical device that ablates fibroids with radiofrequency energy, guided by a built-in intrauterine ultrasound probe. Fifty consecutive women with symptomatic uterine fibroids received treatment with the VizAblate System. Patients had a minimum Menstrual Pictogram score of 120, no desire for fertility, and met additional inclusion and exclusion criteria. The VizAblate System was inserted transcervically and individual fibroids were ablated with radiofrequency energy. An integrated intrauterine ultrasound probe was used for fibroid imaging and targeting. Anesthesia was at the discretion of each investigator. The primary study endpoint was the percentage change in perfused fibroid volume, as assessed by contrast-enhanced MRI at 3 months. Secondary endpoints, reached at 6 months, included safety, percentage reductions in the Menstrual Pictogram (MP) score and the Symptom Severity Score (SSS) subscale of the Uterine Fibroid Symptom-Quality of Life questionnaire (UFS-QOL), along with the rate of surgical reintervention for abnormal uterine bleeding and the mean number of days to return to normal activity. Additional assessments included the Health-Related Quality of Life (HRQOL) subscale of the UFS-QOL, medical reintervention for abnormal uterine bleeding, and procedure times. Fifty patients were treated, representing 92 fibroids. Perfused fibroid volumes were reduced at 3 months by an average of 68.8 ± 27.8 % ( P  < 0.0001; Wilcoxon signed-rank test). At 6 months, mean MP and SSS scores decreased by 60.8 ± 38.2 and 59.7 ± 30.4 %, respectively; the mean HRQOL score increased by 263 ± 468 %. There were two serious adverse events (overnight admissions for abdominal pain and bradycardia, respectively) and no surgical reinterventions. These 6-month results suggest that the VizAblate System is safe and effective in providing relief of abnormal uterine bleeding associated with fibroids, with appropriate safety and a low reintervention rate.

  6. Transurethral Bougie-guided Placement of Suprapubic Catheter Over Guide Wire Monorail in Females: A Novel Technique.

    PubMed

    Dalela, Divakar; Gupta, Piyush; Dalela, Disha; Srinivas, A K; Bhaskar, Ved; Govil, Tuhina; Goel, Apul; Sankhwar, Satya Narayan

    2016-08-01

    To assess the safety and effectiveness of a novel transurethral bougie-guided monorail technique for suprapubic catheterization in females with vesicovaginal fistula. Patients undergoing transvaginal vesicovaginal fistula repair from February 2013 to December 2013 were selected. Suprapubic catheter was placed using this technique and assessment was done in terms of time taken, intraprocedural dislodgement or entanglement of catheter during the procedure, bleeding from the anterior abdominal wall or urethra, or any other intraoperative difficulty. All patients were catheterized smoothly without any intraoperative difficulty, with a mean time of 6 minutes. We describe a new technique of performing suprapubic cystostomy in patients, especially where the bladder cannot be distended. It is safe and easy to perform. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer for detecting bridge cables.

    PubMed

    Xu, Jiang; Wu, Xinjun; Cheng, Cheng; Ben, Anran

    2012-01-01

    Condition assessment of cables has gained considerable attention for the bridge safety. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer is provided to inspect bridge cables. The similarities and differences between the two methods are investigated. The hybrid transducer for bridge cables consists of an aluminum framework, climbing modules, embedded magnetizers and a ribbon coil. The static axial magnetic field provided by the magnetizers meets the needs of the magnetic flux leakage testing and the magnetostrictive guided wave testing. The magnetizers also provide the attraction for the climbing modules. In the magnetic flux leakage testing for the free length of cable, the coil induces the axial leakage magnetic field. In the magnetostrictive guided wave testing for the anchorage zone, the coil provides a pulse high power variational magnetic field for generating guided waves; the coil induces the magnetic field variation for receiving guided waves. The experimental results show that the transducer with the corresponding inspection system could be applied to detect the broken wires in the free length and in the anchorage zone of bridge cables.

  8. A Magnetic Flux Leakage and Magnetostrictive Guided Wave Hybrid Transducer for Detecting Bridge Cables

    PubMed Central

    Xu, Jiang; Wu, Xinjun; Cheng, Cheng; Ben, Anran

    2012-01-01

    Condition assessment of cables has gained considerable attention for the bridge safety. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer is provided to inspect bridge cables. The similarities and differences between the two methods are investigated. The hybrid transducer for bridge cables consists of an aluminum framework, climbing modules, embedded magnetizers and a ribbon coil. The static axial magnetic field provided by the magnetizers meets the needs of the magnetic flux leakage testing and the magnetostrictive guided wave testing. The magnetizers also provide the attraction for the climbing modules. In the magnetic flux leakage testing for the free length of cable, the coil induces the axial leakage magnetic field. In the magnetostrictive guided wave testing for the anchorage zone, the coil provides a pulse high power variational magnetic field for generating guided waves; the coil induces the magnetic field variation for receiving guided waves. The experimental results show that the transducer with the corresponding inspection system could be applied to detect the broken wires in the free length and in the anchorage zone of bridge cables. PMID:22368483

  9. Design and Performance Evaluation of Real-time Endovascular Interventional Surgical Robotic System with High Accuracy.

    PubMed

    Wang, Kundong; Chen, Bing; Lu, Qingsheng; Li, Hongbing; Liu, Manhua; Shen, Yu; Xu, Zhuoyan

    2018-05-15

    Endovascular interventional surgery (EIS) is performed under a high radiation environment at the sacrifice of surgeons' health. This paper introduces a novel endovascular interventional surgical robot that aims to reduce radiation to surgeons and physical stress imposed by lead aprons during fluoroscopic X-ray guided catheter intervention. The unique mechanical structure allowed the surgeon to manipulate the axial and radial motion of the catheter and guide wire. Four catheter manipulators (to manipulate the catheter and guide wire), and a control console which consists of four joysticks, several buttons and two twist switches (to control the catheter manipulators) were presented. The entire robotic system was established on a master-slave control structure through CAN (Controller Area Network) bus communication, meanwhile, the slave side of this robotic system showed highly accurate control over velocity and displacement with PID controlling method. The robotic system was tested and passed in vitro and animal experiments. Through functionality evaluation, the manipulators were able to complete interventional surgical motion both independently and cooperatively. The robotic surgery was performed successfully in an adult female pig and demonstrated the feasibility of superior mesenteric and common iliac artery stent implantation. The entire robotic system met the clinical requirements of EIS. The results show that the system has the ability to imitate the movements of surgeons and to accomplish the axial and radial motions with consistency and high-accuracy. Copyright © 2018 John Wiley & Sons, Ltd.

  10. Feasibility of real-time magnetic resonance-guided angioplasty and stenting of renal arteries in vitro and in Swine, using a new polyetheretherketone-based magnetic resonance-compatible guidewire.

    PubMed

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J; Jacob, Augustinus L; Bilecen, Deniz

    2009-04-01

    Demonstrate the usability of a new polyetheretherketone (PEEK)-based MR-compatible guidewire for renal artery catheterization, angioplasty, and stenting under MR-guidance using MR-visible markers, in vitro and in vivo. The new 0.035'' guidewire with fiber-reinforced PEEK core, a soft tip, and a hydrophilic coating was used. Paramagnetic markings were coated on the wire and nonbraided catheters for passive visualization. Bending stiffness of the guidewire was compared with available hydrophilic guidewires (Terumo Glidewire Stiff and Standard). A human aortic silicon phantom and 2 pigs were used. The study was animal care and use approved by the committee. Under MR-guidance, renal arteries were catheterized, balloon angioplasty was performed, and balloon expandable renal artery stents were deployed in vivo. Post mortem autopsy was performed. Guidewire visibility, pushability, steerability, and device-support capabilities of the marked guidewire were qualitatively assessed. Procedure times were recorded. Bending stiffness of the new PEEK-based wire was comparable with Standard Glidewire. In vitro and in vivo guidewire guidance, catheter configuration, renal artery catheterization, and balloon angioplasty were successful. In pigs, stent deployments were successful in both renal arteries. Autopsy revealed acceptable stent positioning. Guidewire visibility through applied markers was acceptable. Steerability, pushability, and device support were good in vitro and in vivo. The PEEK-based guide allows percutaneous MR-guided renal artery angioplasty and stenting with sufficient visibility, good steerability, pushability, and device support.

  11. Radiofrequency pulse design using nonlinear gradient magnetic fields.

    PubMed

    Kopanoglu, Emre; Constable, R Todd

    2015-09-01

    An iterative k-space trajectory and radiofrequency (RF) pulse design method is proposed for excitation using nonlinear gradient magnetic fields. The spatial encoding functions (SEFs) generated by nonlinear gradient fields are linearly dependent in Cartesian coordinates. Left uncorrected, this may lead to flip angle variations in excitation profiles. In the proposed method, SEFs (k-space samples) are selected using a matching pursuit algorithm, and the RF pulse is designed using a conjugate gradient algorithm. Three variants of the proposed approach are given: the full algorithm, a computationally cheaper version, and a third version for designing spoke-based trajectories. The method is demonstrated for various target excitation profiles using simulations and phantom experiments. The method is compared with other iterative (matching pursuit and conjugate gradient) and noniterative (coordinate-transformation and Jacobian-based) pulse design methods as well as uniform density spiral and EPI trajectories. The results show that the proposed method can increase excitation fidelity. An iterative method for designing k-space trajectories and RF pulses using nonlinear gradient fields is proposed. The method can either be used for selecting the SEFs individually to guide trajectory design, or can be adapted to design and optimize specific trajectories of interest. © 2014 Wiley Periodicals, Inc.

  12. Current oncologic applications of radiofrequency ablation therapies

    PubMed Central

    Shah, Dhruvil R; Green, Sari; Elliot, Angelina; McGahan, John P; Khatri, Vijay P

    2013-01-01

    Radiofrequency ablation (RFA) uses high frequency alternating current to heat a volume of tissue around a needle electrode to induce focal coagulative necrosis with minimal injury to surrounding tissues. RFA can be performed via an open, laparoscopic, or image guided percutaneous approach and be performed under general or local anesthesia. Advances in delivery mechanisms, electrode designs, and higher power generators have increased the maximum volume that can be ablated, while maximizing oncological outcomes. In general, RFA is used to control local tumor growth, prevent recurrence, palliate symptoms, and improve survival in a subset of patients that are not candidates for surgical resection. It’s equivalence to surgical resection has yet to be proven in large randomized control trials. Currently, the use of RFA has been well described as a primary or adjuvant treatment modality of limited but unresectable hepatocellular carcinoma, liver metastasis, especially colorectal cancer metastases, primary lung tumors, renal cell carcinoma, boney metastasis and osteoid osteomas. The role of RFA in the primary treatment of early stage breast cancer is still evolving. This review will discuss the general features of RFA and outline its role in commonly encountered solid tumors. PMID:23671734

  13. Radiofrequency ablation of hepatocellular carcinoma: pros and cons.

    PubMed

    Rhim, Hyunchul; Lim, Hyo K

    2010-09-01

    Among locoregional treatments for hepatocellular carcinoma (HCC), radiofrequency ablation (RFA) has been accepted as the most popular alternative to curative transplantation or resection, and it shows an excellent local tumor control rate and acceptable morbidity. The benefits of RFA have been universally validated by the practice guidelines of international societies of hepatology. The main advantages of RFA include 1) it is minimally invasive with acceptable morbidity, 2) it enables excellent local tumor control, 3) it has promising long-term survival, and 4) it is a multimodal approach. Based on these pros, RFA will play an important role in managing the patient with early HCC (smaller than 3 cm with fewer than four tumors). The main limitations of current RFA technology in hepatic ablation include 1) limitation of ablation volume, 2) technically infeasible in some tumors due to conspicuity and dangerous location, and 3) the heat-sink effect. Many technical approaches have been introduced to overcome those limitations, including a novel guiding modality, use of artificial fluid or air, and combined treatment strategies. RFA will continue to play a role as a representative ablative modality in the management of HCC, even in the era of targeted agents.

  14. Radiofrequency Ablation of Hepatocellular Carcinoma: Pros and Cons

    PubMed Central

    Lim, Hyo K.

    2010-01-01

    Among locoregional treatments for hepatocellular carcinoma (HCC), radiofrequency ablation (RFA) has been accepted as the most popular alternative to curative transplantation or resection, and it shows an excellent local tumor control rate and acceptable morbidity. The benefits of RFA have been universally validated by the practice guidelines of international societies of hepatology. The main advantages of RFA include 1) it is minimally invasive with acceptable morbidity, 2) it enables excellent local tumor control, 3) it has promising long-term survival, and 4) it is a multimodal approach. Based on these pros, RFA will play an important role in managing the patient with early HCC (smaller than 3 cm with fewer than four tumors). The main limitations of current RFA technology in hepatic ablation include 1) limitation of ablation volume, 2) technically infeasible in some tumors due to conspicuity and dangerous location, and 3) the heat-sink effect. Many technical approaches have been introduced to overcome those limitations, including a novel guiding modality, use of artificial fluid or air, and combined treatment strategies. RFA will continue to play a role as a representative ablative modality in the management of HCC, even in the era of targeted agents. PMID:21103289

  15. Fluoroscopic-guided radiofrequency ablation of the basivertebral nerve: application and analysis with multiple imaging modalities in an ovine model (Invited Paper)

    NASA Astrophysics Data System (ADS)

    Bergeron, Jeffrey A.; Eskey, Cliff J.; Attawia, Mohammed; Patel, Samit J.; Ryan, Thomas P.; Pellegrino, Richard; Sutton, Jeffrey; Crombie, John; Paul, B. T.; Hoopes, P. J.

    2005-04-01

    Pathologic involvement of the basivertebral nerve, an intraosseous vertebral nerve found in humans and most mammalian species, may play a role in some forms of back pain. This study was designed to assess the feasibility and effects of the percutaneous delivery of radiofrequency (RF) energy to thermally ablate the basivertebral nerve in the lumbar vertebrae of mature sheep. Using fluoroscopic guidance, a RF bipolar device was placed and a thermal dose delivered to lumbar vertebral bodies in sheep. Post-treatment assessment included multiple magnetic resonance imaging (MRI) techniques and computed tomography (CT). These data were analyzed and correlated to histopathology and morphometry findings to describe the cellular and boney structural changes resulting from the treatment. Imaging modalities MRI and CT can be implemented to non-invasively describe treatment region and volume, marrow cellular effects, and bone density alterations immediately following RF treatment and during convalescence. Such imaging can be utilized to assess treatment effects and refine the thermal dose to vertebral body volume ratio used in treatment planning. This information will be used to improve the therapeutic ratio and develop a treatment protocol for human applications.

  16. CT-Guided Percutaneous Step-by-Step Radiofrequency Ablation for the Treatment of Carcinoma in the Caudate Lobe

    PubMed Central

    Dong, Jun; Li, Wang; Zeng, Qi; Li, Sheng; Gong, Xiao; Shen, Lujun; Mao, Siyue; Dong, Annan; Wu, Peihong

    2015-01-01

    Abstract The location of the caudate lobe and its complex anatomy make caudate lobectomy and radiofrequency ablation (RFA) under ultrasound guidance technically challenging. The objective of the exploratory study was to introduce a novel modality of treatment of lesions in caudate lobe and discuss all details with our experiences to make this novel treatment modality repeatable and educational. The study enrolled 39 patients with liver caudate lobe tumor first diagnosed by computerized tomography (CT) or magnetic resonance imaging (MRI). After consultation of multi-disciplinary team, 7 patients with hepatic caudate lobe lesions were enrolled and accepted CT-guided percutaneous step-by-step RFA treatment. A total of 8 caudate lobe lesions of the 7 patients were treated by RFA in 6 cases and RFA combined with percutaneous ethanol injection (PEI) in 1 case. Median tumor diameter was 29 mm (range, 18–69 mm). A right approach was selected for 6 patients and a dorsal approach for 1 patient. Median operative time was 64 min (range, 59–102 min). Median blood loss was 10 mL (range, 8-16 mL) and mainly due to puncture injury. Median hospitalization time was 4 days (range, 2–5 days). All lesions were completely ablated (8/8; 100%) and no recurrence at the site of previous RFA was observed during median 8 months follow-up (range 3–11 months). No major or life-threatening complications or deaths occurred. In conclusion, percutaneous step-by-step RFA under CT guidance is a novel and effective minimally invasive therapy for hepatic caudate lobe lesions with well repeatability. PMID:26426638

  17. Non-fluoroscopic navigation systems for radiofrequency catheter ablation for supraventricular tachycardia reduce ionising radiation exposure.

    PubMed

    See, Jason; Amora, Jonah L; Lee, Sheldon; Lim, Paul; Teo, Wee Siong; Tan, Boon Yew; Ho, Kah Leng; Lee, Chee Wan; Ching, Chi-Keong

    2016-07-01

    The use of non-fluoroscopic systems (NFS) to guide radiofrequency catheter ablation (RFCA) for the treatment of supraventricular tachycardia (SVT) is associated with lower radiation exposure. This study aimed to determine if NFS reduces fluoroscopy time, radiation dose and procedure time. We prospectively enrolled patients undergoing RFCA for SVT. NFS included EnSiteTM NavXTM or CARTO® mapping. We compared procedure and fluoroscopy times, and radiation exposure between NFS and conventional fluoroscopy (CF) cohorts. Procedural success, complications and one-year success rates were reported. A total of 200 patients over 27 months were included and RFCA was guided by NFS for 79 patients; those with atrioventricular nodal reentrant tachycardia (AVNRT), left-sided atrioventricular reentrant tachycardia (AVRT) and right-sided AVRT were included (n = 101, 63 and 36, respectively). Fluoroscopy times were significantly lower with NFS than with CF (10.8 ± 11.1 minutes vs. 32.0 ± 27.5 minutes; p < 0.001). The mean fluoroscopic dose area product was also significantly reduced with NFS (NSF: 5,382 ± 5,768 mGy*cm2 vs. CF: 21,070 ± 23,311 mGy*cm2; p < 0.001); for all SVT subtypes. There was no significant reduction in procedure time, except for left-sided AVRT ablation (NFS: 79.2 minutes vs. CF: 116.4 minutes; p = 0.001). Procedural success rates were comparable (NFS: 97.5% vs. CF: 98.3%) and at one-year follow-up, there was no significant difference in the recurrence rates (NFS: 5.2% vs. CF: 4.2%). No clinically significant complications were observed in both groups. The use of NFS for RFCA for SVT is safe, with significantly reduced radiation dose and fluoroscopy time. Copyright © Singapore Medical Association.

  18. Histopathology of breast cancer after magnetic resonance-guided high-intensity focused ultrasound and radiofrequency ablation.

    PubMed

    Knuttel, Floortje M; Waaijer, Laurien; Merckel, Laura G; van den Bosch, Maurice A A J; Witkamp, Arjen J; Deckers, Roel; van Diest, Paul J

    2016-08-01

    Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation and radiofrequency ablation (RFA) are being researched as possible substitutes for surgery in breast cancer patients. The histopathological appearance of ablated tissue has not been studied in great detail. This study aimed to compare histopathological features of breast cancer after MR-HIFU ablation and RFA. MR-HIFU ablation and RFA were performed in- and ex-vivo. Tumours in six mastectomy specimens were partially ablated with RFA or MR-HIFU. In-vivo MR-HIFU ablation was performed 3-6 days before excision; RFA was performed in the operation room. Tissue was fixed in formalin and processed to haematoxylin and eosin (H&E) and cytokeratin-8 (CK-8)-stained slides. Morphology and cell viability were assessed. Ex-vivo ablation resulted in clear morphological changes after RFA versus subtle differences after MR-HIFU. CK-8 staining was decreased or absent. H&E tended to underestimate the size of thermal damage. In-vivo MR-HIFU resulted in necrotic-like changes. Surprisingly, some ablated lesions were CK-8-positive. Histopathology after in-vivo RFA resembled ex-vivo RFA, with hyper-eosinophilic stroma and elongated nuclei. Lesion borders were sharp after MR-HIFU and indistinct after RFA. Histopathological differences between MR-HIFU-ablated tissue and RF-ablated tissue were demonstrated. CK-8 was more reliable for cell viability assessment than H&E when used directly after ablation, while H&E was more reliable in ablated tissue left in situ for a few days. Our results contribute to improved understanding of histopathological features in breast cancer lesions treated with minimally invasive ablative techniques. © 2016 John Wiley & Sons Ltd.

  19. CT-guided radiofrequency ablation of osteoid osteoma using a multi-tined expandable electrode system.

    PubMed

    Costanzo, Alessandro; Sandri, Andrea; Regis, Dario; Trivellin, Giacomo; Pierantoni, Silvia; Samaila, Elena; Magnan, Bruno

    2017-10-18

    Radiofrequency ablation (RFA) is the gold standard for the treatment of symptomatic osteoid osteoma (OO) as RFA yields both a high success and low complication rate. It has been widely utilized over the years, but recurrences of OO after this treatment have been documented. These recurrences may be the result of various factors, including incomplete tumor ablation, and are significantly higher in lesions greater than 10 mm. Thus, the need to induce thermal ablation in a wider area led us to use a Multi-Tined Expandable Electrode System (MTEES). In this study we examined the efficacy and safety of RFA using a MTEES in symptomatic OO. Between January 2005 and June 2007, 16 patients with symptomatic OO were treated by CT-guided percutaneous RFA using a MTEES. The diameter of OO ranged from 6 to 15 mm (mean 10±2.6 mm). Patients were evaluated for clinical outcomes, complications and recurrence. Pain evaluation was assessed preoperatively, 2 weeks postoperatively and at last follow-up. Clinical follow-up was available for all patients at a mean of 84.3 months (range 73-96 months). Mean preoperative VAS score was 7.4 (range 5-9), two weeks after the procedure mean VAS score was 0.3 (range 0-1) with a mean change of -7.06 points (p<0.0001). At the last follow-up a complete relief from pain has been observed in all patients. No major and minor complications were observed nor recurrences. RFA using a MTEES has been effective, safe and reliable for the treatment of OOs. This system, by increasing the size of the necrosis, could be a viable alternative to the single needle electrode in lesions larger than 10 mm, reducing the risk of recurrence.

  20. Real-time magnetic resonance imaging-guided radiofrequency atrial ablation and visualization of lesion formation at 3 Tesla.

    PubMed

    Vergara, Gaston R; Vijayakumar, Sathya; Kholmovski, Eugene G; Blauer, Joshua J E; Guttman, Mike A; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W; Daccarett, Marcos; McGann, Christopher J; Macleod, Rob S; Marrouche, Nassir F

    2011-02-01

    Magnetic resonance imaging (MRI) allows visualization of location and extent of radiofrequency (RF) ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT -RI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. The purpose of this study was to develop a 3-Tesla RT MRI-based catheter ablation and lesion visualization system. RF energy was delivered to six pigs under RT MRI guidance. A novel MRI-compatible mapping and ablation catheter was used. Under RT MRI, this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bipolar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2W) half Fourier acquisition with single-shot turbo spin echo (HASTE) sequence during ablation. RT visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or the lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement MRI and macroscopic tissue examination. MRI-compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT MRI guidance. Recording electrograms during RT imaging also is feasible. RT visualization of lesion as it forms during RF energy delivery is possible and was demonstrated using T2W HASTE imaging. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  1. Pulsed radiofrequency of the composite nerve supply to the knee joint as a new technique for relieving osteoarthritic pain: a preliminary report.

    PubMed

    Vas, Lakshmi; Pai, Renuka; Khandagale, Nishigandha; Pattnaik, Manorama

    2014-01-01

    We report a new technique for pulsed radiofrequency (PRF) of the entire nerve supply of the knee as an option in treating osteoarthritis (OA) of knee. We targeted both sensory and motor nerves supplying all the structures around the knee: joint, muscles, and skin to address the entire nociception and stiffness leading to peripheral and central sensitization in osteoarthritis. Ten patients with pain, stiffness, and loss of function in both knees were treated with ultrasonography (USG) guided PRF of saphenous, tibial, and common peroneal nerves along with subsartorial, peripatellar, and popliteal plexuses. USG guided PRF of the femoral nerve was also done to address the innervation of the quadriceps muscle. Assessment of pain (Numerical Rating Scale [NRS], pain DETECT, knee function [Western Ontario and McMaster Universities Osteoarthritis Index- WOMAC]) were documented pre and post PRF at 3 and 6 months. Knee radiographs (Kellgren-Lawrence [K-L] grading) were done before PRF and one week later. All the patients showed a sustained improvement of NRS, pain DETECT, and WOMAC at 3 and 6 months. The significant improvement of patellar position and tibio-femoral joint space was concordant with the patient's reporting of improvement in stiffness and pain. The sustained pain relief and muscle relaxation enabled the patients to optimize physiotherapy thereby improving endurance training to include the daily activities of life. We conclude that OA knee pain is a product of neuromyopathy and that PRF of the sensory and motor nerves appeared to be a safe, effective, and minimally invasive technique. The reduction of pain and stiffness improved the knee function and probably reduced the peripheral and central sensitization.

  2. Percutaneous Sacroiliac Screw Placement: A Prospective Randomized Comparison of Robot-assisted Navigation Procedures with a Conventional Technique

    PubMed Central

    Wang, Jun-Qiang; Wang, Yu; Feng, Yun; Han, Wei; Su, Yong-Gang; Liu, Wen-Yong; Zhang, Wei-Jun; Wu, Xin-Bao; Wang, Man-Yi; Fan, Yu-Bo

    2017-01-01

    Background: Sacroiliac (SI) screw fixation is a demanding technique, with a high rate of screw malposition due to the complex pelvic anatomy. TiRobot™ is an orthopedic surgery robot which can be used for SI screw fixation. This study aimed to evaluate the accuracy of robot-assisted placement of SI screws compared with a freehand technique. Methods: Thirty patients requiring posterior pelvic ring stabilization were randomized to receive freehand or robot-assisted SI screw fixation, between January 2016 and June 2016 at Beijing Jishuitan Hospital. Forty-five screws were placed at levels S1 and S2. In both methods, the primary end point screw position was assessed and classified using postoperative computed tomography. Fisher's exact probability test was used to analyze the screws’ positions. Secondary end points, such as duration of trajectory planning, surgical time after reduction of the pelvis, insertion time for guide wire, number of guide wire attempts, and radiation exposure without pelvic reduction, were also assessed. Results: Twenty-three screws were placed in the robot-assisted group and 22 screws in the freehand group; no postoperative complications or revisions were reported. The excellent and good rate of screw placement was 100% in the robot-assisted group and 95% in the freehand group. The P value (0.009) showed the same superiority in screw distribution. The fluoroscopy time after pelvic reduction in the robot-assisted group was significantly shorter than that in the freehand group (median [Q1, Q3]: 6.0 [6.0, 9.0] s vs. median [Q1, Q3]: 36.0 [21.5, 48.0] s; χ2 = 13.590, respectively, P < 0.001); no difference in operation time after reduction of the pelvis was noted (χ2 = 1.990, P = 0.158). Time for guide wire insertion was significantly shorter for the robot-assisted group than that for the freehand group (median [Q1, Q3]: 2.0 [2.0, 2.7] min vs. median [Q1, Q3]: 19.0 [15.5, 45.0] min; χ2 = 20.952, respectively, P < 0.001). The number of guide wire attempts in the robot-assisted group was significantly less than that in the freehand group (median [Q1, Q3]: 1.0 [1.0,1.0] time vs. median [Q1, Q3]: 7.0 [1.0, 9.0] times; χ2 = 15.771, respectively, P < 0.001). The instrumented SI levels did not differ between both groups (from S1 to S2, χ2 = 4.760, P = 0.093). Conclusions: Accuracy of the robot-assisted technique was superior to that of the freehand technique. Robot-assisted navigation is safe for unstable posterior pelvic ring stabilization, especially in S1, but also in S2. SI screw insertion with robot-assisted navigation is clinically feasible. PMID:29067950

  3. Percutaneous Sacroiliac Screw Placement: A Prospective Randomized Comparison of Robot-assisted Navigation Procedures with a Conventional Technique.

    PubMed

    Wang, Jun-Qiang; Wang, Yu; Feng, Yun; Han, Wei; Su, Yong-Gang; Liu, Wen-Yong; Zhang, Wei-Jun; Wu, Xin-Bao; Wang, Man-Yi; Fan, Yu-Bo

    2017-11-05

    Sacroiliac (SI) screw fixation is a demanding technique, with a high rate of screw malposition due to the complex pelvic anatomy. TiRobot™ is an orthopedic surgery robot which can be used for SI screw fixation. This study aimed to evaluate the accuracy of robot-assisted placement of SI screws compared with a freehand technique. Thirty patients requiring posterior pelvic ring stabilization were randomized to receive freehand or robot-assisted SI screw fixation, between January 2016 and June 2016 at Beijing Jishuitan Hospital. Forty-five screws were placed at levels S1 and S2. In both methods, the primary end point screw position was assessed and classified using postoperative computed tomography. Fisher's exact probability test was used to analyze the screws' positions. Secondary end points, such as duration of trajectory planning, surgical time after reduction of the pelvis, insertion time for guide wire, number of guide wire attempts, and radiation exposure without pelvic reduction, were also assessed. Twenty-three screws were placed in the robot-assisted group and 22 screws in the freehand group; no postoperative complications or revisions were reported. The excellent and good rate of screw placement was 100% in the robot-assisted group and 95% in the freehand group. The P value (0.009) showed the same superiority in screw distribution. The fluoroscopy time after pelvic reduction in the robot-assisted group was significantly shorter than that in the freehand group (median [Q1, Q3]: 6.0 [6.0, 9.0] s vs. median [Q1, Q3]: 36.0 [21.5, 48.0] s; χ2 = 13.590, respectively, P < 0.001); no difference in operation time after reduction of the pelvis was noted (χ2 = 1.990, P = 0.158). Time for guide wire insertion was significantly shorter for the robot-assisted group than that for the freehand group (median [Q1, Q3]: 2.0 [2.0, 2.7] min vs. median [Q1, Q3]: 19.0 [15.5, 45.0] min; χ2 = 20.952, respectively, P < 0.001). The number of guide wire attempts in the robot-assisted group was significantly less than that in the freehand group (median [Q1, Q3]: 1.0 [1.0,1.0] time vs. median [Q1, Q3]: 7.0 [1.0, 9.0] times; χ2 = 15.771, respectively, P < 0.001). The instrumented SI levels did not differ between both groups (from S1 to S2, χ2 = 4.760, P = 0.093). Accuracy of the robot-assisted technique was superior to that of the freehand technique. Robot-assisted navigation is safe for unstable posterior pelvic ring stabilization, especially in S1, but also in S2. SI screw insertion with robot-assisted navigation is clinically feasible.

  4. Smooth bridge between guided waves and spoof surface plasmon polaritons.

    PubMed

    Liu, Liangliang; Li, Zhuo; Gu, Changqing; Xu, Bingzheng; Ning, Pingping; Chen, Chen; Yan, Jian; Niu, Zhenyi; Zhao, Yongjiu

    2015-04-15

    In this work, we build a smooth bridge between a coaxial waveguide and a plasmonic waveguide with subwavelength periodically cylindrical radial grooves, to realize high-efficiency mode conversion between conventional guided waves and spoof surface plasmon polaritons in broadband. This bridge consists of a flaring coaxial waveguide connected with a metal cylindrical wire corrugated with subwavelength gradient radial grooves. Experimental results of the transmission and reflection coefficients show excellent agreement with the numerical simulations. The proposed scheme can be extended readily to other bands and the bridge structure can find potential applications in the integration of conventional microwave or terahertz devices with plasmonic circuits.

  5. [Initial clinical experience with radiofrequency-guided percutaneous vertebral augmentation in the treatment of vertebral compression fractures].

    PubMed

    Marosfoi, Miklós; Kulcsár, Zsolt; Berentei, Zsolt; Gubucz, István; Szikora, István

    2011-07-30

    Percutaenous Vertebroplasty (PVP) is effective in alleviating pain and facilitating early mobilization following vertebral compression fractures. The relatively high risk of extravertebral leakage due to uncontrolled delivery of low viscosity bone cement is an inherent limitation of the technique. The aim of this research is to investigate the ability of controlled cement delivery in decreasing the rate of such complications by applying radiofrequency heating to regulate cement viscosity. Thirty two vetebrae were treated in 28 patients as part of an Ethics Committee approved multicenter clinical trial using RadioFreqency assisted Percutaenous Vertebral Augmentation (RF-PVA) technique. This technique is injecting low viscosity polymethylmethacrylate (PMMA) bone cement using a pressure controlled hydraulic pump and applying radiofrequency heating to increase cement viscosity prior to entering the vertebral body. All patients were screened for any cement leakage by X-ray and CT scan. The intensity of pain was recorded on a Visual Analog Scale (VAS) and the level of physical activity on the Oswestry Disability Index (ODI) prior to, one day, one month and three months following procedure. All procedures were technically successful. There were no clinical complication, intraspinal or intraforaminal cement leakage. In nine cases (29%) a small amount of PMMA entered the intervertebral space through the broken end plate. Intensity of pain by VAS was reduced from a mean of 7.0 to 2.5 and physical inactivity dropped on the ODI from 52% to 23% three months following treatment. In this small series controlled cement injection using RF-PVA was capable of preventing clinically hazardous extravertebral cement leakage while achieving outcomes similar to that of conventional vertebroplasty.

  6. Comparison of Noninvasive High-Intensity Focused Ultrasound with Radiofrequency Ablation of Osteoid Osteoma.

    PubMed

    Sharma, Karun V; Yarmolenko, Pavel S; Celik, Haydar; Eranki, Avinash; Partanen, Ari; Smitthimedhin, Anilawan; Kim, Aerang; Oetgen, Matthew; Santos, Domiciano; Patel, Janish; Kim, Peter

    2017-11-01

    To evaluate clinical feasibility and safety of magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) treatment of symptomatic osteoid osteoma and to compare clinical response with standard of care treatment. Nine subjects with radiologically confirmed, symptomatic osteoid osteoma were treated with MR-HIFU in an institutional review board-approved clinical trial. Treatment feasibility and safety were assessed. Clinical response was evaluated in terms of analgesic requirement, visual analog scale pain score, and sleep quality. Anesthesia, procedure, and recovery times were recorded. This MR-HIFU group was compared with a historical control group of 9 consecutive patients treated with radiofrequency ablation. Nine subjects (7 male, 2 female; 16 ± 6 years) were treated with MR-HIFU without technical difficulties or any serious adverse events. There was significant decrease in their median pain scores 4 weeks within treatment (6 vs 0, P < .01). Total pain resolution and cessation of analgesics were achieved in 8 of 9 patients after 4 weeks. In the radiofrequency ablation group, 9 patients (8 male, 1 female; 10 ± 6 years) were treated in routine clinical practice. All 9 demonstrated complete pain resolution and cessation of medications by 4 weeks with a significant decrease in median pain scores (9 vs 0, P < .001). One developed a second-degree skin burn, but there were no other adverse events. Procedure times and treatment charges were comparable between the 2 groups. This pilot study shows that MR-HIFU treatment of osteoid osteoma refractory to medical therapy is feasible and can be performed safely in pediatric patients. Clinical response is comparable with standard of care treatment but without any incisions or exposure to ionizing radiation. ClinicalTrials.govNCT02349971. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Prospective Evaluation of Electromyography-Guided Phrenic Nerve Monitoring During Superior Vena Cava Isolation to Anticipate Phrenic Nerve Injury.

    PubMed

    Miyazaki, Shinsuke; Ichihara, Noboru; Nakamura, Hiroaki; Taniguchi, Hiroshi; Hachiya, Hitoshi; Araki, Makoto; Takagi, Takamitsu; Iwasawa, Jin; Kuroi, Akio; Hirao, Kenzo; Iesaka, Yoshito

    2016-04-01

    Right phrenic nerve injury (PNI) is a major concern during superior vena cava (SVC) isolation due to the anatomical close proximity. The functional and histological severity of PNI parallels the degree of the reduction in the compound motor action potential (CMAP) amplitude. This study aimed to evaluate the feasibility of monitoring CMAPs during SVC isolation to anticipate PNI during atrial fibrillation (AF) ablation. Thirty-nine paroxysmal AF patients were prospectively enrolled. Radiofrequency energy was delivered point-by-point for 30 seconds with 20 W until eliminating all SVC potentials after the pulmonary vein isolation. Right diaphragmatic CMAPs were obtained from modified surface electrodes by pacing from the right subclavian vein. Radiofrequency applications were applied without fluoroscopy under CMAP monitoring at sites with phrenic nerve capture by high output pacing. Electrical SVC isolation was successfully achieved with a mean of 9.4 ± 3.3 applications in all patients. In 3 (7.5%) patients, the SVC was isolated without radiofrequency delivery at phrenic nerve capture sites. Among a total of 346 applications in the remaining 36 patients, 71 (20.5%) were delivered while monitoring CMAPs. In 1 (1.4%) application, the RF application was interrupted due to a decrease in the CMAP amplitude. However, no PNI was detected on fluoroscopy, and the decreased amplitude recovered spontaneously. The remaining 70 (98.6%) applications exhibited no significant changes in the CMAP amplitude throughout the applications (from 1.01 ± 0.47 to 0.98 ± 0.45 mV, P = 0.383). Stable right diaphragmatic CMAPs could be obtained, and monitoring CMAPs might be useful for anticipating right PNI during SVC isolation. © 2016 Wiley Periodicals, Inc.

  8. A Magnetic Resonance Imaging-Conditional External Cardiac Defibrillator for Resuscitation Within the Magnetic Resonance Imaging Scanner Bore.

    PubMed

    Schmidt, Ehud J; Watkins, Ronald D; Zviman, Menekhem M; Guttman, Michael A; Wang, Wei; Halperin, Henry A

    2016-10-01

    Subjects undergoing cardiac arrest within a magnetic resonance imaging (MRI) scanner are currently removed from the bore and then from the MRI suite, before the delivery of cardiopulmonary resuscitation and defibrillation, potentially increasing the risk of mortality. This precludes many higher-risk (acute ischemic and acute stroke) patients from undergoing MRI and MRI-guided intervention. An MRI-conditional cardiac defibrillator should enable scanning with defibrillation pads attached and the generator ON, enabling application of defibrillation within the seconds of MRI after a cardiac event. An MRI-conditional external defibrillator may improve patient acceptance for MRI procedures. A commercial external defibrillator was rendered 1.5 Tesla MRI-conditional by the addition of novel radiofrequency filters between the generator and commercial disposable surface pads. The radiofrequency filters reduced emission into the MRI scanner and prevented cable/surface pad heating during imaging, while preserving all the defibrillator monitoring and delivery functions. Human volunteers were imaged using high specific absorption rate sequences to validate MRI image quality and lack of heating. Swine were electrically fibrillated (n=4) and thereafter defibrillated both outside and inside the MRI bore. MRI image quality was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface pads did not create artifacts deeper than 6 mm below the skin surface. Radiofrequency heating was within US Food and Drug Administration guidelines. Defibrillation was completely successful inside and outside the MRI bore. A prototype MRI-conditional defibrillation system successfully defibrillated in the MRI without degrading the image quality or increasing the time needed for defibrillation. It can increase patient acceptance for MRI procedures. © 2016 American Heart Association, Inc.

  9. CT-Guided Transfacet Pedicle Screw Fixation in Facet Joint Syndrome: A Novel Approach

    PubMed Central

    Manfré, Luigi

    2014-01-01

    Summary Axial microinstability secondary to disc degeneration and consequent chronic facet joint syndrome (CFJS) is a well-known pathological entity, usually responsible for low back pain (LBP). Although posterior lumbar fixation (PIF) has been widely used for lumbar spine instability and LBP, complications related to wrong screw introduction, perineural scars and extensive muscle dissection leading to muscle dysfunction have been described. Radiofrequency ablation (RFA) of facet joints zygapophyseal nerves conventionally used for pain treatment fails in approximately 21% of patients. We investigated a “covert-surgery” minimal invasive technique to treat local spinal instability and LBP, using a novel fully CT-guided approach in patients with axial instability complicated by CFJS resistant to radioablation, by introducing direct fully or partially threaded transfacet screws (transfacet fixation - TFF), to acquire solid arthrodesis, reducing instability and LBP. The CT-guided procedure was well tolerated by all patients in simple analogue sedation, and mean operative time was approximately 45 minutes. All eight patients treated underwent clinical and CT study follow-up at two months, revealing LBP disappearance in six patients, and a significant reduction of lumbar pain in two. In conclusion, CT-guided TFF is a fast and safe technique when facet posterior fixation is needed. PMID:25363265

  10. Image-guided tumor ablation: standardization of terminology and reporting criteria.

    PubMed

    Goldberg, S Nahum; Grassi, Clement J; Cardella, John F; Charboneau, J William; Dodd, Gerald D; Dupuy, Damian E; Gervais, Debra A; Gillams, Alice R; Kane, Robert A; Lee, Fred T; Livraghi, Tito; McGahan, John; Phillips, David A; Rhim, Hyunchul; Silverman, Stuart G; Solbiati, Luigi; Vogl, Thomas J; Wood, Bradford J; Vedantham, Suresh; Sacks, David

    2009-07-01

    The field of interventional oncology with use of image-guided tumor ablation requires standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison between treatments that use different technologies, such as chemical (ethanol or acetic acid) ablation, and thermal therapies, such as radiofrequency (RF), laser, microwave, ultrasound, and cryoablation. This document provides a framework that will hopefully facilitate the clearest communication between investigators and will provide the greatest flexibility in comparison between the many new, exciting, and emerging technologies. An appropriate vehicle for reporting the various aspects of image-guided ablation therapy, including classification of therapies and procedure terms, appropriate descriptors of imaging guidance, and terminology to define imaging and pathologic findings, are outlined. Methods for standardizing the reporting of follow-up findings and complications and other important aspects that require attention when reporting clinical results are addressed. It is the group's intention that adherence to the recommendations will facilitate achievement of the group's main objective: improved precision and communication in this field that lead to more accurate comparison of technologies and results and, ultimately, to improved patient outcomes. The intent of this standardization of terminology is to provide an appropriate vehicle for reporting the various aspects of image-guided ablation therapy.

  11. Screen printed flexible radiofrequency identification tag for oxygen monitoring.

    PubMed

    Martínez-Olmos, A; Fernández-Salmerón, J; Lopez-Ruiz, N; Rivadeneyra Torres, A; Capitan-Vallvey, L F; Palma, A J

    2013-11-19

    In this work, a radiofrequency identification (RFID) tag with an optical indicator for the measurement of gaseous oxygen is described. It consists of an O2 sensing membrane of PtOEP together with a full electronic system for RFID communication, all printed on a flexible substrate. The membrane is excited by an LED at 385 nm wavelength and the intensity of the luminescence generated is registered by means of a digital color detector. The output data corresponding to the red coordinate of the RGB color space is directly related to the concentration of O2, and it is sent to a microcontroller. The RFID tag is designed and implemented by screen printing on a flexible substrate for the wireless transmission of the measurement to a remote reader. It can operate in both active and passive mode, obtaining the power supply from the electromagnetic waves of the RFID reader or from a small battery, respectively. This system has been fully characterized and calibrated including temperature drifts, showing a high-resolution performance that allows measurement of very low values of oxygen content. Therefore this system is perfectly suitable for its use in modified atmosphere packaging where the oxygen concentration is reduced below 2%. As the reading of the O2 concentration inside the envelope is carried out with an external RFID reader using wireless communication, there is no need for perforations for probes or wires, so the packaging remains completely closed. With the presented device, a limit of detection of 40 ppm and a resolution as low as 0.1 ppm of O2 can be reached with a low power consumption of 3.55 mA.

  12. Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation.

    PubMed

    Deneke, Thomas; Bünz, Kathrin; Bastian, Annely; Päsler, Marcus; Anders, Helge; Lehmann, Rainer; Meuser, Wolfgang; de Groot, Joris R; Horlitz, Marc; Haberkorn, Ron; Mügge, Andreas; Shin, Dong-In

    2011-03-01

    A novel ablation system has been introduced for rapid treatment of atrial fibrillation (AF). This system delivers duty-cycled phased radiofrequency (RF) energy via an over-the-wire catheter (PVAC® , Medtronic) to achieve pulmonary vein (PV) isolation. Lower power and depth control suggests that collateral damage might be minimized. However, no studies have investigated the potential for thermal effect and damage to the esophagus. Ninety consecutive patients undergoing PV-isolation were evaluated. Group A (48 patients) had continuous luminal esophageal temperature (LET) monitoring using a temperature probe with 3 metal electrodes located in the vicinity of the targeted PV ostia. Ablation ceased when LET exceeded 40 °C. Only patients with LET ≥ 39 °C underwent endoscopic evaluation to assess esophageal damage. Group B (42 patients) excluded LET monitoring but all patients underwent endoscopy. In Group A, 27 (56%) patients showed LET ≥ 39 °C (mean LET 40.5 °C). Endoscopy revealed esophageal alterations in 5 (8%) (3 erythema and 2 intramural bleeding). One hundred eighty-nine out of 190 (99.5%) targeted PVs were successfully isolated, with 1 PV unsuccessful due to high LET. In Group B all 165 targeted PVs (100%) were successfully isolated. Endoscopy in Group 2 revealed no esophageal alterations. Using a duty-cycled, phased RF ablation system is safe and effective to isolate PVs. No Eso alteration was documented after ablation when LET was not monitored. This suggests that the LET probe may contribute to the thermal effect. Whether the documented increments in LET are due to direct tissue heating or possible interaction between the LET probe requires further investigation. © 2010 Wiley Periodicals, Inc.

  13. Proposed Optimal Fluoroscopic Targets for Cooled Radiofrequency Neurotomy of the Sacral Lateral Branches to Improve Clinical Outcomes: An Anatomical Study.

    PubMed

    Stout, Alison; Dreyfuss, Paul; Swain, Nathan; Roberts, Shannon; Loh, Eldon; Agur, Anne

    2017-11-23

    Current sacroiliac joint (SIJ) cooled radiofrequency (RF) is based on fluoroscopic anatomy of lateral branches (LBs) in three specimens. Recent studies confirm significant variation in LB positions. To determine if common fluoroscopic needle placements for cooled SIJ RF are adequate to lesion all S1-3 LBs. If not, would different targets improve lesion accuracy? The LBs of 20 cadavers were dissected bilaterally (40 SIJs), and 26 G radiopaque wires were sutured to the LBs. With a 10-mm radius ruler centered at each foramen, standard targets were assessed, as judged by a clockface on the right, for S1 and S2 at 2:30, 4:00, and 5:30 positions and at S3 at 2:30 and 4:00. Mirror image targets were assessed on the left. Assuming an 8-mm lesion diameter, the percentage of LBs that would not be ablated for each level was determined. Imaging through the superior end plate of S1 was compared against segment specific (SS) imaging. Nine point four percent of LBs would not be ablated at S1 vs 0.99% at S2 vs 35% at S3, and 60% of the 40 SIJs would be completely denervated using current targets. SS imaging did not improve results. Alternate target locations could improve the miss rate to 2.8% at S1 and 0% at S3 and would ablate all LBs in 95% of SIJs. Using a conservative 8-mm lesion measurement, contemporary cooled RF needle targets are inadequate to lesion all target LBs. Modifications to current targets are recommended to increase the effectiveness of the procedure. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  14. Radiofrequency heating of metallic dental devices during 3.0 T MRI

    PubMed Central

    Hasegawa, M; Miyata, K; Abe, Y; Ishigami, T

    2013-01-01

    Objectives: To estimate the risk of injury from radiofrequency (RF) heating of metallic dental devices in use during 3.0 T MRI. Methods: The whole-body specific absorption rate (WB-SAR) was calculated on the basis of saline temperature elevation under the maximum RF irradiation for 15 min to determine the operation parameters for the heating test. The temperature changes of three types of three-unit bridges, a full-arch fixed dental prosthesis and an orthodontic appliance in use during MRI with a 3.0 T MR system (Magnetom® Verio; Siemens AG, Erlangen, Germany) were then tested in accordance with the American Society for Testing and Materials F2182-09 standardized procedure under the maximum RF heating during 15 min RF irradiation. Results: The system console-predicted WB-SAR was approximately 1.4 W kg−1 and that measured with a saline phantom was 2.1 W kg−1. In the assessment of RF heating, the highest temperature increase was +1.80 °C in the bridges, +1.59 °C in the full-arch fixed dental prosthesis and +2.61 °C in the orthodontic appliance. Conclusions: The relatively minor RF heating of dental casting material-based prostheses in Magnetom Verio systems in the normal operating mode should not pose a risk to patients. However, orthodontic appliances may exhibit RF heating above the industrial standard (CENELEC standard prEN45502-2-3); therefore, the wire should be removed from the bracket or a spacer should be used between the appliance and the oral mucosa during MRI. PMID:23520391

  15. Effects of heat treatment on shape-setting and non-linearmechanical properties of Nitinol stent

    NASA Astrophysics Data System (ADS)

    Liu, Xiaopeng; Wang, Yinong; Qi, Min; Yang, Dazhi

    2007-07-01

    NiTi shape memory alloy is a temperature sensitive material with non-linear mechanical properties and good biocompatibility, which can be used for medical devices such as stent, catheter guide wire and orthodontic wire. The majority of nitinol stents are of the self-expanding type basing on the superelasticity. Nitinol stents are shape set into the open condition and compressed and inserted into the delivery catheter. Additional the shape-setting treatment can be used as a tool to accurately tune the transformation temperatures and mechanical properties. In this study, different heat treatments have been performed on the Ti-50.7at%Ni alloy wires. And results of shape-setting, austenite transformation finish temperature and non-linear mechanical property of NiTi shape memory alloy at body temperature have been investigated. The experimental results show that the proper shape-setting temperature should be chosen between 450-550 °C. And the shape-setting results were stabilization when the NiTi wires were constrain-treated at 500 and 550°C and ageing time longer than 10 minutes. The austenite finish temperatures increased with ageing time and increased first and then decreased with ageing temperature. The peak values were obtained at 400°C. When the heat treatments was performed at the same temperature, both the upper plateau stresses and lower plateau stresses decreased with the ageing time. Most of treated nitinol wires owned good recovery ability at body temperature and the permanent sets were less than 0.05% when short time ageing treatment was performed at 500°C.

  16. Heat accumulation during sequential cortical bone drilling.

    PubMed

    Palmisano, Andrew C; Tai, Bruce L; Belmont, Barry; Irwin, Todd A; Shih, Albert; Holmes, James R

    2016-03-01

    Significant research exists regarding heat production during single-hole bone drilling. No published data exist regarding repetitive sequential drilling. This study elucidates the phenomenon of heat accumulation for sequential drilling with both Kirschner wires (K wires) and standard two-flute twist drills. It was hypothesized that cumulative heat would result in a higher temperature with each subsequent drill pass. Nine holes in a 3 × 3 array were drilled sequentially on moistened cadaveric tibia bone kept at body temperature (about 37 °C). Four thermocouples were placed at the center of four adjacent holes and 2 mm below the surface. A battery-driven hand drill guided by a servo-controlled motion system was used. Six samples were drilled with each tool (2.0 mm K wire and 2.0 and 2.5 mm standard drills). K wire drilling increased temperature from 5 °C at the first hole to 20 °C at holes 6 through 9. A similar trend was found in standard drills with less significant increments. The maximum temperatures of both tools increased from <0.5 °C to nearly 13 °C. The difference between drill sizes was found to be insignificant (P > 0.05). In conclusion, heat accumulated during sequential drilling, with size difference being insignificant. K wire produced more heat than its twist-drill counterparts. This study has demonstrated the heat accumulation phenomenon and its significant effect on temperature. Maximizing the drilling field and reducing the number of drill passes may decrease bone injury. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Light modulated electron beam driven radiofrequency emitter

    DOEpatents

    Wilson, M.T.; Tallerico, P.J.

    1979-10-10

    The disclosure relates to a light modulated electron beam-driven radiofrequency emitter. Pulses of light impinge on a photoemissive device which generates an electron beam having the pulse characteristics of the light. The electron beam is accelerated through a radiofrequency resonator which produces radiofrequency emission in accordance with the electron, hence, the light pulses.

  18. Radiofrequency for the Treatment of Lumbar Radicular Pain: Impact on Surgical Indications.

    PubMed

    Trinidad, José Manuel; Carnota, Ana Isabel; Failde, Inmaculada; Torres, Luis Miguel

    2015-01-01

    Study Design. Quasiexperimental study. Objective. To investigate whether radiofrequency treatment can preclude the need for spinal surgery in both the short term and long term. Background. Radiofrequency is commonly used to treat lumbosacral radicular pain. Only few studies have evaluated its effects on surgical indications. Methods. We conducted a quasiexperimental study of 43 patients who had been scheduled for spinal surgery. Radiofrequency was indicated for 25 patients. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment (pulsed radiofrequency of dorsal root ganglion, 76%; conventional radiofrequency of the medial branch, 12%; combined technique, 12%). The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment. In addition, we also evaluated adverse effects, ODI, NRS. Results. We observed after treatment with radiofrequency 80% of patients rejected spinal surgery in the short term and 76% in the long term. We conclude that radiofrequency is a useful treatment strategy that can achieve very similar outcomes to spinal surgery. Patients also reported a very high level of satisfaction (84% satisfied/very satisfied). We also found that optimization of the electrical parameters of the radiofrequency improved the outcome of this technique.

  19. Radiofrequency ablation of hepatocellular carcinoma: Mono or multipolar?

    PubMed

    Cartier, Victoire; Boursier, Jérôme; Lebigot, Jérôme; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Aubé, Christophe

    2016-03-01

    Thermo-ablation by radiofrequency is recognized as a curative treatment for early-stage hepatocellular carcinoma. However, local recurrence may occur because of incomplete peripheral tumor destruction. Multipolar radiofrequency has been developed to increase the size of the maximal ablation zone. We aimed to compare the efficacy of monopolar and multipolar radiofrequency for the treatment of hepatocellular carcinoma and determine factors predicting failure. A total of 171 consecutive patients with 214 hepatocellular carcinomas were retrospectively included. One hundred fifty-eight tumors were treated with an expandable monopolar electrode and 56 with a multipolar technique using several linear bipolar electrodes. Imaging studies at 6 weeks after treatment, then every 3 months, assessed local effectiveness. Radiofrequency failure was defined as persistent residual tumor after two sessions (primary radiofrequency failure) or local tumor recurrence during follow-up. This study received institutional review board approval (number 2014/77). Imaging showed complete tumor ablation in 207 of 214 lesions after the first session of radiofrequency. After a second session, only two cases of residual viable tumor were observed. During follow-up, there were 46 local tumor recurrences. Thus, radiofrequency failure occurred in 48/214 (22.4%) cases. By multivariate analysis, technique (P < 0.001) and tumor size (P = 0.023) were independent predictors of radiofrequency failure. Failure rate was lower with the multipolar technique for tumors < 25 mm (P = 0.023) and for tumors between 25 and 45 mm (P = 0.082). There was no difference for tumors ≥ 45 mm (P = 0.552). Compared to monopolar radiofrequency, multipolar radiofrequency improves tumor ablation with a subsequent lower rate of local tumor recurrence. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  20. 2.75-Inch Motor Manufacturing Waste Minimization Project

    DTIC Science & Technology

    2006-06-19

    Certification Program FEM Finite element model HFMI Highly Filled Materials Institute HOE Heat of explosion ICT Institute of Chemical Technology IHDIV...Trinitrotoluene TOW Tube-launched, optically tracked, wire-guided missile TPE Thermoplastic elastomers TSE Twin screw mixer/extruder VPDES Virginia Pollution...extruded and test fired. 1996–1997 Inert TPE Processing: Thermoplastic elastomers (TPE) are ideal binders for “green energetics” because they do

  1. Magnetic navigation system assisted percutaneous coronary intervention: a comparison to the conventional approach in daily practice.

    PubMed

    Li, Chun-Jian; Wang, Hui; Yang, Zhi-Jian; Cao, Ke-Jiang

    2011-01-01

    The benefits of the magnetic navigation system (MNS) for percutaneous coronary intervention (PCI) remain unclear, and a comparison of the MNS assisted approach to the conventional approach for PCI, when used in daily practice, is little studied. This study aimed to investigate the benefits of an MNS assisted technique as compared to the conventional technique for PCI. Forty-eight consecutive patients scheduled for PCI were recruited between December 2009 and April 2010. MNS assisted PCIs were performed on 54 target vessels. Another 45 patients with 54 target vessels undergoing conventional PCIs were selected from a historical population of patients to match the MNS group according to the coronary lesion type (ACC/AHA classification). Emergency PCIs and chronic total occlusions were excluded from both groups. Analyses were performed using Stata 9.2 statistical software. There were no significant differences between the baseline characteristics of the MNS group and the control group. The success rates were 100.0% for the MNS assisted PCI and 98.1% for the conventional PCI, which did not reach a significant difference (P = 1.000); there were also no significant differences in terms of guide wire crossing time ((51.7 ± 30.5) seconds vs. (57.5 ± 49.4) seconds, P = 0.448), operation time ((28.4 ± 15.9) minutes vs. (28.0 ± 24.7) minutes, P = 0.935), X-ray exposure ((458.1 ± 350.1) µGym(2) vs. (558.7 ± 451.7) µGym(2), P = 0.197; and (94.2 ± 80.9) mGy vs. (96.2 ± 77.3) mGy, P = 0.895) or contrast usage ((7.3 ± 4.0) ml vs. (6.1 ± 3.7) ml, P = 0.121) between the two groups. However, a trend toward shorter guide wire crossing time and less X-ray exposure were observed for the magnetic group. In daily practice, MNS assisted PCI resulted in a similar procedural success rate, operation time, and contrast usage, with a trend toward shorter guide wire crossing time and less X-ray exposure when compared to the conventional PCI.

  2. Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control

    PubMed Central

    2013-01-01

    Background Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. Methods Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure’s positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. Results One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). Conclusions MRI-ROLL offers a precise, technically feasible, safe, and rapid means for performing preoperative MRI localizations in the breast. PMID:24044428

  3. Magnetic Resonance Imaging of the Codman Microsensor Transducer Used for Intraspinal Pressure Monitoring: Findings From the Injured Spinal Cord Pressure Evaluation Study.

    PubMed

    Phang, Isaac; Mada, Marius; Kolias, Angelos G; Newcombe, Virginia F J; Trivedi, Rikin A; Carpenter, Adrian; Hawkes, Rob C; Papadopoulos, Marios C

    2016-05-01

    Laboratory and human study. To test the Codman Microsensor Transducer (CMT) in a cervical gel phantom. To test the CMT inserted to monitor intraspinal pressure in a patient with spinal cord injury. We recently introduced the technique of intraspinal pressure monitoring using the CMT to guide management of traumatic spinal cord injury [Werndle et al. Crit Care Med 2014;42:646]. This is analogous to intracranial pressure monitoring to guide management of patients with traumatic brain injury. It is unclear whether magnetic resonance imaging (MRI) of patients with spinal cord injury is safe with the intraspinal pressure CMT in situ. We measured the heating produced by the CMT placed in a gel phantom in various configurations. A 3-T MRI system was used with the body transmit coil and the spine array receive coil. A CMT was then inserted subdurally at the injury site in a patient who had traumatic spinal cord injury and MRI was performed at 1.5 T. In the gel phantom, heating of up to 5°C occurred with the transducer wire placed straight through the magnet bore. The heating was abolished when the CMT wire was coiled and passed away from the bore. We then tested the CMT in a patient with an American Spinal Injuries Association grade C cervical cord injury. The CMT wire was placed in the configuration that abolished heating in the gel phantom. Good-quality T1 and T2 images of the cord were obtained without neurological deterioration. The transducer remained functional after the MRI. Our data suggest that the CMT is MR conditional when used in the spinal configuration in humans. Data from a large patient group are required to confirm these findings. N/A.

  4. Mouth development.

    PubMed

    Chen, Justin; Jacox, Laura A; Saldanha, Francesca; Sive, Hazel

    2017-09-01

    A mouth is present in all animals, and comprises an opening from the outside into the oral cavity and the beginnings of the digestive tract to allow eating. This review focuses on the earliest steps in mouth formation. In the first half, we conclude that the mouth arose once during evolution. In all animals, the mouth forms from ectoderm and endoderm. A direct association of oral ectoderm and digestive endoderm is present even in triploblastic animals, and in chordates, this region is known as the extreme anterior domain (EAD). Further support for a single origin of the mouth is a conserved set of genes that form a 'mouth gene program' including foxA and otx2. In the second half of this review, we discuss steps involved in vertebrate mouth formation, using the frog Xenopus as a model. The vertebrate mouth derives from oral ectoderm from the anterior neural ridge, pharyngeal endoderm and cranial neural crest (NC). Vertebrates form a mouth by breaking through the body covering in a precise sequence including specification of EAD ectoderm and endoderm as well as NC, formation of a 'pre-mouth array,' basement membrane dissolution, stomodeum formation, and buccopharyngeal membrane perforation. In Xenopus, the EAD is also a craniofacial organizer that guides NC, while reciprocally, the NC signals to the EAD to elicit its morphogenesis into a pre-mouth array. Human mouth anomalies are prevalent and are affected by genetic and environmental factors, with understanding guided in part by use of animal models. WIREs Dev Biol 2017, 6:e275. doi: 10.1002/wdev.275 For further resources related to this article, please visit the WIREs website. © 2017 The Authors. WIREs Developmental Biology published by Wiley Periodicals, Inc.

  5. Clinics in diagnostic imaging (174). L5 vertebral superior facet osteoblastoma (OB).

    PubMed

    Subramanian, Manickam; Chou, Hong; Chokkappan, Kabilan; Peh, Wilfred Cg

    2017-02-01

    A 25-year-old man presented with chronic low back pain and occasional radiation to the right lower limb. Magnetic resonance imaging and computed tomography (CT) of the lumbar spine showed an osteolytic expansile lesion with a central sclerotic nidus in the right superior facet of the L5 vertebra and surrounding marrow oedema. The diagnosis of osteoblastoma was made based on imaging findings and confirmed after CT-guided biopsy. Radiofrequency ablation of the lesion was successfully performed. The patient tolerated the procedure well and showed symptomatic relief. The imaging features and management of osteoblastoma are discussed. Copyright: © Singapore Medical Association.

  6. Management of lymphatic malformations in children.

    PubMed

    Bagrodia, Naina; Defnet, Ann M; Kandel, Jessica J

    2015-06-01

    To review the literature on lymphatic malformations and to provide current opinion about the management of these lesions. Current treatment options include nonoperative management, surgery, sclerotherapy, radiofrequency ablation, and laser therapy. New therapies are emerging, including sildenafil, propranolol, sirolimus, and vascularized lymph node transfer. The primary focus of management centers on the patient's quality of life. Multimodal treatment of lymphatic malformations continues to expand as new information about the biology and genetics of these lesions is discovered, in addition to knowledge gained from clinical practice. A patient-centered approach should guide timing and modality of treatment. Continued study of lymphatic malformations will increase and solidify a treatment algorithm for these complicated lesions.

  7. Pain control requirements for percutaneous ablation of renal tumors: cryoablation versus radiofrequency ablation--initial observations.

    PubMed

    Allaf, Mohamad E; Varkarakis, Ioannis M; Bhayani, Sam B; Inagaki, Takeshi; Kavoussi, Louis R; Solomon, Stephen B

    2005-10-01

    To retrospectively compare the pain control requirements of patients undergoing computed tomography (CT)-guided percutaneous radiofrequency (RF) ablation with those of patients undergoing CT-guided percutaneous cryoablation of small (< or = 4-cm) renal tumors. The study was HIPAA compliant and received institutional review board exemption; informed consent was not required. Medical and procedure records of patients who underwent RF ablation and cryoablation of renal tumors from June 19, 2003, to February 28, 2004, were retrospectively reviewed for clinical data, tumor characteristics, and anesthesia information. During the study period, 10 men (mean age, 66.5 years) underwent cryoablation of 11 renal lesions, and 14 patients (11 men, four women; mean age, 68.1 years) underwent RF ablation of 15 renal tumors. Analgesic and sedative requirements during the procedure were compared. Standard anesthesia consisted of 5 mL of 1% lidocaine injected locally, and conscious sedation consisted of 50 microg of fentanyl and 1 mg of midazolam administered intravenously. The Fisher exact test and Student t test were used to compare clinical factors and drug requirements between the two groups. There was no difference in terms of patient demographics, tumor diameter, or distribution of central versus noncentral lesions between the two groups. Cryoablation was associated with a significantly lower dose of fentanyl (165.0 microg [RF group] vs 75.0 microg [cryoablation group]; P < .001) and midazolam (2.9 mg [RF group] vs 1.6 mg [cryoablation group]; P = .026). In the RF group, one patient required general anesthesia, one patient required supplemental narcotics (5 mg of oxycodone) and sedatives (1 mg lorezapam), and one patient became apneic for a brief interval after receiving additional narcotics for pain during the procedure. An additional RF session was terminated early in one patient because of pain, and further medication could not be administered owing to bradycardia. No patients in the cryoablation group required any additional or alternate anesthetics. Image-guided percutaneous cryoablation of small (< or = 4-cm) renal lesions appears to require less analgesia than RF ablation. Prospective trials with validated pain scales are needed to examine this further. RSNA, 2005

  8. Thermal Ablation of T1c Renal Cell Carcinoma: A Comparative Assessment of Technical Performance, Procedural Outcome, and Safety of Microwave Ablation, Radiofrequency Ablation, and Cryoablation.

    PubMed

    Zhou, Wenhui; Arellano, Ronald S

    2018-04-06

    To evaluate perioperative outcomes of thermal ablation with microwave (MW), radiofrequency (RF), and cryoablation for stage T1c renal cell carcinoma (RCC). A retrospective analysis of 384 patients (mean age, 71 y; range, 22-88 y) was performed between October 2006 and October 2016. Mean radius, exophytic/endophytic, nearness to collecting system or sinus, anterior/posterior, and location relative to polar lines; preoperative aspects and dimensions used for anatomic classification; and centrality index scores were 6.3, 7.9, and 2.7, respectively. Assessment of pre- and postablation serum blood urea nitrogen, creatinine, and estimated glomerular filtration rate was performed to assess functional outcomes. Linear regression analyses were performed to compare sedation medication dosages among the three treatment cohorts. Univariable and multivariable logistic regression analyses were performed to compare rates of residual disease and complications among treatment modalities. A total of 437 clinical stage T1N0M0 biopsy-proven RCCs measuring 1.2-6.9 cm were treated with computed tomography (CT)-guided MW ablation (n = 44; 10%), RF ablation (n = 347; 79%), or cryoablation (n = 46; 11%). There were no significant differences in patient demographic or tumor characteristics among cohorts. Complication rates and immediate renal function changes were similar among the three ablation modalities (P = .46 and P = .08, respectively). MW ablation was associated with significantly decreased ablation time (P < .05), procedural time (P < .05), and dosage of sedative medication (P < .05) compared with RF ablation and cryoablation. CT-guided percutaneous MW ablation is comparable to RF ablation or cryoablation for the treatment of stage T1N0M0 RCC with regard to treatment response and is associated with shorter treatment times and less sedation than RF ablation or cryoablation. In addition, the safety profile of CT-guided MW ablation is noninferior to those of RF ablation or cryoablation. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  9. Advanced capability RFID system

    DOEpatents

    Gilbert, Ronald W.; Steele, Kerry D.; Anderson, Gordon A.

    2007-09-25

    A radio-frequency transponder device having an antenna circuit configured to receive radio-frequency signals and to return modulated radio-frequency signals via continuous wave backscatter, a modulation circuit coupled to the antenna circuit for generating the modulated radio-frequency signals, and a microprocessor coupled to the antenna circuit and the modulation circuit and configured to receive and extract operating power from the received radio-frequency signals and to monitor inputs on at least one input pin and to generate responsive signals to the modulation circuit for modulating the radio-frequency signals. The microprocessor can be configured to generate output signals on output pins to associated devices for controlling the operation thereof. Electrical energy can be extracted and stored in an optional electrical power storage device.

  10. Comb-based radiofrequency photonic filters with rapid tunability and high selectivity

    NASA Astrophysics Data System (ADS)

    Supradeepa, V. R.; Long, Christopher M.; Wu, Rui; Ferdous, Fahmida; Hamidi, Ehsan; Leaird, Daniel E.; Weiner, Andrew M.

    2012-03-01

    Photonic technologies have received considerable attention regarding the enhancement of radiofrequency electrical systems, including high-frequency analogue signal transmission, control of phased arrays, analog-to-digital conversion and signal processing. Although the potential of radiofrequency photonics for the implementation of tunable electrical filters over broad radiofrequency bandwidths has been much discussed, the realization of programmable filters with highly selective filter lineshapes and rapid reconfigurability has faced significant challenges. A new approach for radiofrequency photonic filters based on frequency combs offers a potential route to simultaneous high stopband attenuation, fast tunability and bandwidth reconfiguration. In one configuration, tuning of the radiofrequency passband frequency is demonstrated with unprecedented (~40 ns) speed by controlling the optical delay between combs. In a second, fixed filter configuration, cascaded four-wave mixing simultaneously broadens and smoothes the comb spectra, resulting in Gaussian radiofrequency filter lineshapes exhibiting an extremely high (>60 dB) main lobe to sidelobe suppression ratio and (>70 dB) stopband attenuation.

  11. Accuracy of electromyography needle placement in cadavers: non-guided vs. ultrasound guided.

    PubMed

    Boon, Andrea J; Oney-Marlow, Theresa M; Murthy, Naveen S; Harper, Charles M; McNamara, Terrence R; Smith, Jay

    2011-07-01

    Accuracy of needle electromyography is typically ensured by use of anatomical landmarks and auditory feedback related to voluntary activation of the targeted muscle; however, in certain clinical situations, landmarks may not be palpable, auditory feedback may be limited or not present, and targeting a specific muscle may be more critical. In such settings, image guidance might significantly enhance accuracy. Two electromyographers with different levels of experience examined 14 muscles in each of 4 fresh-frozen cadaver lower limbs. Each muscle was tested a total of eight times; four fine wires were inserted without ultrasound (US) guidance and four were inserted under US guidance. Overall accuracy as well as accuracy rates for the individual electromyographers were calculated. Non-guided needle placement was significantly less accurate than US-guided needle placement, particularly in the hands of less experienced electromyographers, supporting the use of real-time US guidance in certain challenging situations in the electromyography laboratory. Copyright © 2011 Wiley Periodicals, Inc.

  12. Hand gesture guided robot-assisted surgery based on a direct augmented reality interface.

    PubMed

    Wen, Rong; Tay, Wei-Liang; Nguyen, Binh P; Chng, Chin-Boon; Chui, Chee-Kong

    2014-09-01

    Radiofrequency (RF) ablation is a good alternative to hepatic resection for treatment of liver tumors. However, accurate needle insertion requires precise hand-eye coordination and is also affected by the difficulty of RF needle navigation. This paper proposes a cooperative surgical robot system, guided by hand gestures and supported by an augmented reality (AR)-based surgical field, for robot-assisted percutaneous treatment. It establishes a robot-assisted natural AR guidance mechanism that incorporates the advantages of the following three aspects: AR visual guidance information, surgeon's experiences and accuracy of robotic surgery. A projector-based AR environment is directly overlaid on a patient to display preoperative and intraoperative information, while a mobile surgical robot system implements specified RF needle insertion plans. Natural hand gestures are used as an intuitive and robust method to interact with both the AR system and surgical robot. The proposed system was evaluated on a mannequin model. Experimental results demonstrated that hand gesture guidance was able to effectively guide the surgical robot, and the robot-assisted implementation was found to improve the accuracy of needle insertion. This human-robot cooperative mechanism is a promising approach for precise transcutaneous ablation therapy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. Image-guided tumor ablation: standardization of terminology and reporting criteria--a 10-year update.

    PubMed

    Ahmed, Muneeb; Solbiati, Luigi; Brace, Christopher L; Breen, David J; Callstrom, Matthew R; Charboneau, J William; Chen, Min-Hua; Choi, Byung Ihn; de Baère, Thierry; Dodd, Gerald D; Dupuy, Damian E; Gervais, Debra A; Gianfelice, David; Gillams, Alice R; Lee, Fred T; Leen, Edward; Lencioni, Riccardo; Littrup, Peter J; Livraghi, Tito; Lu, David S; McGahan, John P; Meloni, Maria Franca; Nikolic, Boris; Pereira, Philippe L; Liang, Ping; Rhim, Hyunchul; Rose, Steven C; Salem, Riad; Sofocleous, Constantinos T; Solomon, Stephen B; Soulen, Michael C; Tanaka, Masatoshi; Vogl, Thomas J; Wood, Bradford J; Goldberg, S Nahum

    2014-10-01

    Image-guided tumor ablation has become a well-established hallmark of local cancer therapy. The breadth of options available in this growing field increases the need for standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison among treatments that use different technologies, such as chemical (eg, ethanol or acetic acid) ablation, thermal therapies (eg, radiofrequency, laser, microwave, focused ultrasound, and cryoablation) and newer ablative modalities such as irreversible electroporation. This updated consensus document provides a framework that will facilitate the clearest communication among investigators regarding ablative technologies. An appropriate vehicle is proposed for reporting the various aspects of image-guided ablation therapy including classification of therapies, procedure terms, descriptors of imaging guidance, and terminology for imaging and pathologic findings. Methods are addressed for standardizing reporting of technique, follow-up, complications, and clinical results. As noted in the original document from 2003, adherence to the recommendations will improve the precision of communications in this field, leading to more accurate comparison of technologies and results, and ultimately to improved patient outcomes. Online supplemental material is available for this article . © RSNA, 2014.

  14. Stereotactic Laser Ablation for Medically Intractable Epilepsy: The Next Generation of Minimally Invasive Epilepsy Surgery

    PubMed Central

    LaRiviere, Michael J.; Gross, Robert E.

    2016-01-01

    Epilepsy is a common, disabling illness that is refractory to medical treatment in approximately one-third of patients, particularly among those with mesial temporal lobe epilepsy. While standard open mesial temporal resection is effective, achieving seizure freedom in most patients, efforts to develop safer, minimally invasive techniques have been underway for over half a century. Stereotactic ablative techniques, in particular, radiofrequency (RF) ablation, were first developed in the 1960s, with refinements in the 1990s with the advent of modern computed tomography and magnetic resonance-based imaging. In the past 5 years, the most recent techniques have used MRI-guided laser interstitial thermotherapy (LITT), the development of which began in the 1980s, saw refinements in MRI thermal imaging through the 1990s, and was initially used primarily for the treatment of intracranial and extracranial tumors. The present review describes the original stereotactic ablation trials, followed by modern imaging-guided RF ablation series for mesial temporal lobe epilepsy. The developments of LITT and MRI thermometry are then discussed. Finally, the two currently available MRI-guided LITT systems are reviewed for their role in the treatment of mesial temporal lobe and other medically refractory epilepsies. PMID:27995127

  15. Image-guided Tumor Ablation: Standardization of Terminology and Reporting Criteria—A 10-Year Update

    PubMed Central

    Solbiati, Luigi; Brace, Christopher L.; Breen, David J.; Callstrom, Matthew R.; Charboneau, J. William; Chen, Min-Hua; Choi, Byung Ihn; de Baère, Thierry; Dodd, Gerald D.; Dupuy, Damian E.; Gervais, Debra A.; Gianfelice, David; Gillams, Alice R.; Lee, Fred T.; Leen, Edward; Lencioni, Riccardo; Littrup, Peter J.; Livraghi, Tito; Lu, David S.; McGahan, John P.; Meloni, Maria Franca; Nikolic, Boris; Pereira, Philippe L.; Liang, Ping; Rhim, Hyunchul; Rose, Steven C.; Salem, Riad; Sofocleous, Constantinos T.; Solomon, Stephen B.; Soulen, Michael C.; Tanaka, Masatoshi; Vogl, Thomas J.; Wood, Bradford J.; Goldberg, S. Nahum

    2014-01-01

    Image-guided tumor ablation has become a well-established hallmark of local cancer therapy. The breadth of options available in this growing field increases the need for standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison among treatments that use different technologies, such as chemical (eg, ethanol or acetic acid) ablation, thermal therapies (eg, radiofrequency, laser, microwave, focused ultrasound, and cryoablation) and newer ablative modalities such as irreversible electroporation. This updated consensus document provides a framework that will facilitate the clearest communication among investigators regarding ablative technologies. An appropriate vehicle is proposed for reporting the various aspects of image-guided ablation therapy including classification of therapies, procedure terms, descriptors of imaging guidance, and terminology for imaging and pathologic findings. Methods are addressed for standardizing reporting of technique, follow-up, complications, and clinical results. As noted in the original document from 2003, adherence to the recommendations will improve the precision of communications in this field, leading to more accurate comparison of technologies and results, and ultimately to improved patient outcomes. © RSNA, 2014 Online supplemental material is available for this article. PMID:24927329

  16. Navigation for fluoroscopy-guided cryo-balloon ablation procedures of atrial fibrillation

    NASA Astrophysics Data System (ADS)

    Bourier, Felix; Brost, Alexander; Kleinoeder, Andreas; Kurzendorfer, Tanja; Koch, Martin; Kiraly, Attila; Schneider, Hans-Juergen; Hornegger, Joachim; Strobel, Norbert; Kurzidim, Klaus

    2012-02-01

    Atrial fibrillation (AFib), the most common arrhythmia, has been identified as a major cause of stroke. The current standard in interventional treatment of AFib is the pulmonary vein isolation (PVI). PVI is guided by fluoroscopy or non-fluoroscopic electro-anatomic mapping systems (EAMS). Either classic point-to-point radio-frequency (RF)- catheter ablation or so-called single-shot-devices like cryo-balloons are used to achieve electrically isolation of the pulmonary veins and the left atrium (LA). Fluoroscopy-based systems render overlay images from pre-operative 3-D data sets which are then merged with fluoroscopic imaging, thereby adding detailed 3-D information to conventional fluoroscopy. EAMS provide tracking and visualization of RF catheters by means of electro-magnetic tracking. Unfortunately, current navigation systems, fluoroscopy-based or EAMS, do not provide tools to localize and visualize single shot devices like cryo-balloon catheters in 3-D. We present a prototype software for fluoroscopy-guided ablation procedures that is capable of superimposing 3-D datasets as well as reconstructing cyro-balloon catheters in 3-D. The 3-D cyro-balloon reconstruction was evaluated on 9 clinical data sets, yielded a reprojected 2-D error of 1.72 mm +/- 1.02 mm.

  17. Radiofrequency and microwave radiation in the microelectronics industry.

    PubMed

    Cohen, R

    1986-01-01

    The microscopic precision required to produce minute integrated circuits is dependent on several processes utilizing radiofrequency and microwave radiation. This article provides a review of radiofrequency and microwave exposures in microelectronics and of the physical and biologic properties of these types of radiation; summarizes the existing, relevant medical literature; and provides the clinician with guidelines for diagnosis and treatment of excessive exposures to microwave and radiofrequency radiation.

  18. The radiofrequency frontier: a review of radiofrequency and combined radiofrequency pulsed-light technology in aesthetic medicine.

    PubMed

    Sadick, Neil; Sorhaindo, Lian

    2005-05-01

    Radiofrequency (RF) and combined RF light source technologies have established themselves as safe and effective treatment modalities for several dermatologic procedures, including skin tightening, hair and leg vein removal, acne scarring, skin rejuvenation, and wrinkle reduction. This article reviews the technology, clinical applications, and recent advances of RF and combined RF light/laser source technologies in aesthetic medicine.

  19. Therapeutic genome engineering via CRISPR-Cas systems.

    PubMed

    Moreno, Ana M; Mali, Prashant

    2017-07-01

    Differences in genomes underlie most organismal diversity, and aberrations in genomes underlie many disease states. With the growing knowledge of the genetic and pathogenic basis of human disease, development of safe and efficient platforms for genome and epigenome engineering will transform our ability to therapeutically target human diseases and also potentially engineer disease resistance. In this regard, the recent advent of clustered regularly interspaced short palindromic repeats (CRISPR)-CRISPR-associated (Cas) RNA-guided nuclease systems have transformed our ability to target nucleic acids. Here we review therapeutic genome engineering applications with a specific focus on the CRISPR-Cas toolsets. We summarize past and current work, and also outline key challenges and future directions. WIREs Syst Biol Med 2017, 9:e1380. doi: 10.1002/wsbm.1380 For further resources related to this article, please visit the WIREs website. © 2017 Wiley Periodicals, Inc.

  20. Cutting a Drop of Water Pinned by Wire Loops Using a Superhydrophobic Surface and Knife

    PubMed Central

    Yanashima, Ryan; García, Antonio A.; Aldridge, James; Weiss, Noah; Hayes, Mark A.; Andrews, James H.

    2012-01-01

    A water drop on a superhydrophobic surface that is pinned by wire loops can be reproducibly cut without formation of satellite droplets. Drops placed on low-density polyethylene surfaces and Teflon-coated glass slides were cut with superhydrophobic knives of low-density polyethylene and treated copper or zinc sheets, respectively. Distortion of drop shape by the superhydrophobic knife enables a clean break. The driving force for droplet formation arises from the lower surface free energy for two separate drops, and it is modeled as a 2-D system. An estimate of the free energy change serves to guide when droplets will form based on the variation of drop volume, loop spacing and knife depth. Combining the cutting process with an electrofocusing driving force could enable a reproducible biomolecular separation without troubling satellite drop formation. PMID:23029297

Top