Sample records for radioiodine intercomparison program

  1. Human radiation studies: Remembering the early years. Oral history of Dr. Nadine Foreman, M.D., August 19, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-07-01

    Dr. Nadine Foreman was interviewed by representatives of the US DOE Office of Human Radiation Experiments (OHRE). Dr. Foreman was selected for interview because of the position she held at the University of California, San Francisco. Following a brief biographical sketch, Dr. Foreman describes her work with Dr. Mayo Soley using I-131 in treatment of hyperthyroidism, selection criteria for patients in the radioiodine project, work with Dr. Earl Miller, work at Highland Hospital, radioiodine treatment of diffuse toxic goiter (myxedema), the radiophosphorus and radioiodine programs with Dr. Bert Low-Beer, and treatment of polycythemia vera.

  2. ARM/GCSS/SPARC TWP-ICE CRM Intercomparison Study

    NASA Technical Reports Server (NTRS)

    Fridlind, Ann; Ackerman, Andrew; Petch, Jon; Field, Paul; Hill, Adrian; McFarquhar, Greg; Xie, Shaocheng; Zhang, Minghua

    2010-01-01

    Specifications are provided for running a cloud-resolving model (CRM) and submitting results in a standardized format for inclusion in a n intercomparison study and archiving for public access. The simulated case study is based on measurements obtained during the 2006 Tropical Warm Pool - International Cloud Experiment (TWP-ICE) led by the U. S. department of Energy Atmospheric Radiation Measurement (ARM) program. The modeling intercomparison study is based on objectives developed in concert with the Stratospheric Processes And their Role in Climate (SPARC) program and the GEWEX cloud system study (GCSS) program. The Global Energy and Water Cycle Experiment (GEWEX) is a core project of the World Climate Research PRogramme (WCRP).

  3. RECONSTRUCTION OF RADIATION DOSES IN A CASE-CONTROL STUDY OF THYROID CANCER FOLLOWING THE CHERNOBYL ACCIDENT

    PubMed Central

    Drozdovitch, Vladimir; Khrouch, Valeri; Maceika, Evaldas; Zvonova, Irina; Vlasov, Oleg; Bratilova, Angelica; Gavrilin, Yury; Goulko, Guennadi; Hoshi, Masaharu; Kesminiene, Ausrele; Shinkarev, Sergey; Tenet, Vanessa; Cardis, Elisabeth; Bouville, Andre

    2010-01-01

    A population-based case-control study of thyroid cancer was carried out in contaminated regions of Belarus and Russia among persons who were exposed during childhood and adolescence to fallout from the Chernobyl accident. For each study subject, individual thyroid doses were reconstructed for the following pathways of exposure: (1) intake of 131I via inhalation and ingestion; (2) intake of short-lived radioiodines (132I, 133I, and 135I) and radiotelluriums (131mTe, 132Te) via inhalation and ingestion; (3) external dose from radionuclides deposited on the ground; and (4) ingestion of 134Cs and 137Cs. A series of intercomparison exercises validated the models used for reconstruction of average doses to populations of specific age groups as well as of individual doses. Median thyroid doses from all factors for study subjects were estimated to be 0.37 and 0.034 Gy in Belarus and Russia, respectively. The highest individual thyroid doses among the subjects were 10.2 Gy in Belarus and 5.3 Gy in Russia. Iodine-131 intake was the main pathway for thyroid exposure. Estimated doses from short-lived radioiodines and radiotelluriums ranged up to 0.53 Gy. Reconstructed individual thyroid doses from external exposure ranged up to 0.1 Gy, while those from internal exposure due to ingested cesium did not exceed 0.05 Gy. The uncertainty of the reconstructed individual thyroid doses, characterized by the geometric standard deviation, varies from 1.7 to 4.0 with a median of 2.2. PMID:20539120

  4. A survey of owners' perceptions and experiences of radioiodine treatment of feline hyperthyroidism in the UK.

    PubMed

    Boland, Lara A; Murray, Jane K; Bovens, Catherine Pv; Hibbert, Angie

    2014-08-01

    The efficacy of radioiodine treatment of feline hyperthyroidism is well established; however, limited information is known about owners' perceptions or experiences of radioiodine. This study aimed to examine factors that influence owner treatment choices and their opinions following radioiodine. Surveys were sent to owners of cats referred for radioiodine treatment between 2002 and 2011 (radioiodine group; 264 cats) and owners of non-radioiodine-treated hyperthyroid cats seen at first-opinion practices (control group; 199 cats). The response rate was 67.0% (310 returned: 175 radioiodine, 135 control). Of 135 controls, 72 (53.3%) were unaware of radioiodine as a treatment option. Owners of cats ⩾15 years old and uninsured cats were less likely to pursue radioiodine. Cost of treatment, travel distance, potential human or animal health risks and waiting periods for radioiodine had a low impact on owners' treatment choice. Owners reported a moderate level of concern about treatment hospitalisation length, which included (158 respondents) the possibility of the cat being unhappy 130 (82.3%), owner missing the cat 102 (64.6%), inappetence 50 (31.6%), other pets missing the cat 32 (20.3%), development of co-morbid disease 28 (17.7%) and side effects 25 (15.8%). Owners assessed their cat's quality of life on a scale of 1 (very poor) to 10 (excellent), as 4 (4) (median [interquartile range]) pre-radioiodine (134 respondents) and 9 (2) post-radioiodine (131 respondents). Of 132 respondents, 121 (91.7%) were happy with their decision to choose radioiodine. The results of this questionnaire may assist veterinarians in addressing common owner concerns when discussing radioiodine as a treatment option for hyperthyroidism. © ISFM and AAFP 2014.

  5. a Study of the Interferences with the On-Line Radioiodine Measurement Under Nuclear Accident Conditions

    NASA Astrophysics Data System (ADS)

    Tseng, Tung-Tse

    In this research the interferences with the on -line detection of radioiodines, under nuclear accident conditions, were studied. The special tool employed for this research is the developed on-line radioiodine monitor (the Penn State Radioiodine Monitor), which is capable of detecting low levels of radioiodine on-line in air containing orders of magnitude higher levels of radioactive noble gases. Most of the data reported in this thesis were collected during a series of experiments called "Source -Term Experiment Program (STEP)." The experiments were conducted at the Argonne National Laboratory's TREAT reactor located at the Idaho National Engineering Laboratory (INEL). In these tests, fission products were released from the Light Water Reactor (LWR) test fuels as a result of simulating a reactor accident. The Penn State Monitor was then used to sample the fission products accumulated in a large container which simulated the reactor containment building. The test results proved that the Penn State Monitor was not affected significantly by the passage of large amounts of noble gases through the system. Also, it confirmed the predicted results that the operation of conventional on-line radioiodine detectors would, under nuclear accident conditions, be seriously impaired by the passage of high concentrations of radioactive noble gases through such systems. This work also demonstrated that under conditions of high noble gas concentrations and low radioiodine concentrations, the formation of noble-gas-decayed alkali metals can seriously interfere with the on-line detection of radioiodine, especially during the 24 hours immediately after the accident. The decayed alkali metal particulates were also found to be much more penetrating than the ordinary type of particulates, since a large fraction (15%) of the particulates were found to penetrate through the commonly used High Efficiency Particulate Air (HEPA) filter (rated >99.97% for 0.3 (mu)m particulate). Also, a significant fraction ((TURN)40%) of these particles became deposited on silver zeolite iodine filters inside the counting chamber. Finally, the Penn State Monitor proved itself to be a powerful research tool for the on-line source term studies since it can easily produce near noble-gas-free spectra during the real time studies occurring under simulated nuclear accident conditions.

  6. Primary hyperthyroidism--diagnosis and treatment. Indications and contraindications for radioiodine therapy.

    PubMed

    Gurgul, Edyta; Sowinski, Jerzy

    2011-01-01

    Isotope therapy is one of the methods used in primary hyperthyroidism. The therapy is based on short-range beta radiation emitted from radioactive iodine. Radioiodine administration must always be preceded by pharmacological normalization of thyroid function. Otherwise, post-radiation thyrocyte destruction and thyroid hormones release may lead to hyperthyroidism exacerbation. Indications for radioiodine therapy in Graves-Basedow disease include recurrent hyperthyroidism after thyrostatic treatment or thyroidectomy and side-effects observed during thyrostatic treatment. In toxic nodule, isotope therapy is the first choice therapy. Radioiodine is absorbed only in autonomous nodule. Therefore, it destroys only this area and does not damage the remaining thyroid tissue. In toxic goitre, radioiodine is used mostly in recurrent nodules. Absolute contraindications for radioiodine treatment are pregnancy and lactation. Relative contraindications are thyroid nodules suspected of malignancy and age under 15 years. In patients with thyroid nodules suspected of malignancy, radioiodine treatment may be applied as a preparation for surgery, if thyrostatic drugs are ineffective or contraindicated. In children, radioiodine therapy should be considered in recurrent toxic goitre and when thyrostatic drugs are ineffective. In patients with Graves-Basedow disease and thyroid-associated orbitopathy, radioiodine treatment may increase the inflammatory process and exacerbate the ophthalmological symptoms. However, thyroid-associated orbitopathy cannot be considered as a contraindication for isotope therapy. The potential carcinogenic properties of radioiodine, especially associated with tissues with high iodine uptake (thyroid, salivary glands, stomach, intestine, urinary tract, breast), have not been confirmed.

  7. ISMIP6: Ice Sheet Model Intercomparison Project for CMIP6

    NASA Technical Reports Server (NTRS)

    Nowicki, S.

    2015-01-01

    ISMIP6 (Ice Sheet Model Intercomparison Project for CMIP6) targets the Cryosphere in a Changing Climate and the Future Sea Level Grand Challenges of the WCRP (World Climate Research Program). Primary goal is to provide future sea level contribution from the Greenland and Antarctic ice sheets, along with associated uncertainty. Secondary goal is to investigate feedback due to dynamic ice sheet models. Experiment design uses and augment the existing CMIP6 (Coupled Model Intercomparison Project Phase 6) DECK (Diagnosis, Evaluation, and Characterization of Klima) experiments. Additonal MIP (Model Intercomparison Project)- specific experiments will be designed for ISM (Ice Sheet Model). Effort builds on the Ice2sea, SeaRISE (Sea-level Response to Ice Sheet Evolution) and COMBINE (Comprehensive Modelling of the Earth System for Better Climate Prediction and Projection) efforts.

  8. [The evaluation of selected oxidative stress parameters in patients after radioiodine treatment of hyperthyroidism].

    PubMed

    Owczarek, Tomasz; Kowalczyk, Edward; Poliwczak, Adam Rafał; Bała, Agnieszka; Broncel, Marlena

    2012-06-01

    Oxidative stress is an important factor of the hyperthyroidism pathogenesis. The radioiodine therapy is an approved treatment method of this common disease and it is connected with exposure to ionizing radiation, which induces increased generation of reactive oxygen species in patient's organism. The aim of the study was to estimate the selected oxidative stress parameters in hyperthyroid patients, initially treated with thiamazole and subsequently with radioiodine. The evaluated parameters were the activity of superoxide dismutase (CuZn-SOD), catalase (CAT) and glutathione peroxidase (GPx) in erythrocytes as well as the level of total antioxidative status (TAS) in plasma. In the study participated 29 healthy volunteers and 27 hyperthyroid patients, treated with thiamazole and prepared for radioiodine therapy. The antioxidant enzymes activity and the level of TAS were measured before administration of radioiodine therapeutic dose (average 18.47 +/- 8.81 mCi) as well as 30 days after treatment and achieving euthyreosis. Hyperthyroid patients prepared with thiamazole for radioiodine therapy demonstrated higher GPx activity (p < 0.0001) and lower TAS level (p < 0.0001) than healthy people. Patients, who become euthyroid after 30 days from radioiodine therapy, were characterised by the increased activity of CAT (p < 0.05) and GPx (p < 0.05) as well as the higher level of TAS (p < 0.05). Patients after radioiodine treatment in comparison to the control group had the same activity of CAT and the level of TAS, although the activity of CuZn-SOD (p < 0.05) and GPx (p < 0.0001) occurred higher than in the control group. Moreover patients with hyperthyroidism before radioiodine treatment showed positive correlation between the level of TSH and TAS, whereas after radioiodine therapy they demonstrated positive correlation between the level of TSH and the activity of CuZn-SOD, CAT and GPx. However, there was no statistically significant correlation between the quantity of administrated radioiodine dose and the value of estimated oxidative stress parameters. The results of the study show the occurrence of oxidative stress in hyperthyroid patients prepared with thiamazole to radioiodine therapy. Euthyreosis achieved by radioiodine treatment effected on normalisation of the activity of CAT and the level of TAS, although the activity of CuZn-SOD and GPx stayed increased. After the analysis of correlation between TSH level, radioiodine dose and measured parameters we can conclude that the intensity of oxidative stress more depends on current thyreometabolic state than on the therapeutic method applied.

  9. Exhalation of ¹³¹I after radioiodine therapy: measurements in exhaled air.

    PubMed

    Schomäcker, Klaus; Sudbrock, Ferdinand; Fischer, Thomas; Dietlein, Markus; Kobe, Carsten; Gaidouk, Mark; Schicha, Harald

    2011-12-01

    A considerable amount of radioiodine is exhaled after radioiodine therapy leading to unwanted radiation exposure through inhalation. This study focused on the concentration of radioactivity exhaled and its chemical nature. Air exhaled by 47 patients receiving (131)I-iodine for different thyroid diseases (toxic goitre n = 26, Graves' disease n = 13, thyroid cancer n = 8) was investigated with a portable constant air-flow sampler. Different chemical iodine species were collected separately (organic, elemental and aerosolic) up to 26 h after administration of the radioiodine capsule. The data approximated to a monoexponential time-activity curve when integrated over 100 h. The radioactivity in the filters was measured with a well counter at defined time points after administration. The radioactivity of (131)I in the exhaled air 1 h after administration ranged from 1 to 100 kBq/m(3). Two parameters (half-life of radioiodine exhalation and time-integrated activity over 100 h) were substantially higher in patients with cancer after near-total thyroidectomy (11.8 ± 2.1 h and 535 ± 140 kBq / m(3), respectively) than in patients with hyperfunctioning thyroid tissue due to toxic adenoma (7.6 ± 2.5 h and 115 ± 27 kBq / m(3), respectively) or Graves' disease (6.4 ± 3.6 h and 113 ± 38 kBq / m(3), respectively). The percentage of radioiodine in the exhaled air in relation to radioiodine administered to the patient was between 80 ppm and 150 ppm. The fraction of organically bound radioiodine (mean value) for all time points after administration was 94-99.9%. This percentage did not depend on the type of thyroid disease. The amount of exhaled radioiodine is small but by no means negligible on the first day after administration. This is the first study to provide experimental evidence on a systematic basis that radioiodine becomes exhalable in vivo, i.e. in the patient. The mechanism of organification of orally administered radioiodine remains to be investigated.

  10. The effect of chewing-gum on dose rate of salivary gland in differentiated thyroid carcinoma patients treated with radioiodine.

    PubMed

    Haghighatafshar, Mahdi; Nowshad, Reza; Etemadi, Zahra; Ghaedian, Tahereh

    2018-04-26

    Although, different methods have been suggested on reducing salivary gland radiation after radioiodine administration, an effective preventive or therapeutic measure is still debateful. To the best of our knowledge this is the second study that aimed to evaluate the effect of chewing-gum as a sialagogue on the radioiodine content of salivary gland, and radioiodine- induced symptoms of salivary gland dysfunction. Twenty two patients who were referred to radioiodine therapy were randomized into chewing-gum (group A) and control (group B) groups. Anterior and posterior planar images including both head and neck were obtained 2, 6, 12, 24 and 48 hours after the administration of radioiodine in all patients and round regions of interest (ROI) were drawn for both left and right parotid glands with a rectangular ROI in the region of cerebrum as the background. All patients were followed once, 6 months after radioiodine administration via a phone call for subjective evaluation of symptoms related to salivary gland damage. There was no significant difference between the two groups regarding the mean age, gender and initial iodine activity. The geometric mean of background-corrected count per administrated dose and acquisition time was calculated for bilateral parotid glands. This normalized parotid count showed a significant reduction in net parotid count in both groups during the first 48 hours after the radioiodine administration. However, no significant difference was found between the groups according to the amount and pattern of dose reduction in this time period. This study revealed that chewing-gum had no significant effect on the radioiodine content of parotid glands during the first 48 hours after radioiodine administration. Also, no significant difference was found in the incidence of relevant symptoms after 6 months comparing both groups.

  11. Radioiodine treatment for pediatric hyperthyroid Grave's disease.

    PubMed

    Chao, Ma; Jiawei, Xie; Guoming, Wang; Jianbin, Liu; Wanxia, Liu; Driedger, Al; Shuyao, Zuo; Qin, Zhang

    2009-10-01

    Grave's disease (GD) is an autoimmune disease in which excessive amounts of thyroid hormones circulate in the blood. Treatment for pediatric GD includes (1) antithyroid drugs (ATD), (2) radioiodine, and (3) thyroidectomy. Yet, the optimal therapy remains controversial. We collected studies from all electronically available sources as well as from conferences held in China. All studies using radioiodine and/or ATD and/or thyroidectomy were included. Information was found on 1,874 pediatric GD patients treated with radioiodine, 1,279 patients treated with ATD and 1,362 patients treated surgically. The cure rate for radioiodine was 49.8%; the incidence of hypothyroidism, 37.8%; of relapse, 6.3%; of adverse effects, 1.55%; and of drop outs, 0.6%. These data show that radioiodine treatment is safe and effective in pediatric GD with significant lower incidence of relapse and adverse effects but significantly higher incidence of hypothyroidism as compared with both ATD and thyroidectomy. For the time being, radioiodine treatment for pediatric GD remains an excellent first-line therapy and a good second-line therapy for patients with ATD failure, severe complications, or poor compliance.

  12. Radioiodine therapy in patients with Graves' disease and the effects of prior carbimazole therapy.

    PubMed

    Karyampudi, Arun; Hamide, Abdoul; Halanaik, Dhanapathi; Sahoo, Jaya Prakash; Kamalanathan, Sadishkumar

    2014-09-01

    The use of radioiodine as the first line of treatment in Graves' disease is restricted in India because of its limited availability and an unrealistic risk perception associated with it. Additionally, the effectiveness of radioiodine ablation in Graves' disease is influenced by many factors. Prior medical antithyroid therapy is one such important factor. To analyze the efficacy of low dose radioiodine therapy (5 mCi) in treatment of naive patients of Graves' disease in comparison to that in which it was already primed with an antithyroid drug, carbimazole. A non-randomized, interventional study conducted in the Department of Medicine and Endocrinology of a tertiary care institute in South India. The study had two groups; Group A (36 treatment naive, uncomplicated Graves' disease patients) and B (34 Graves' disease patients on carbimazole prior to radioiodine therapy). Both groups had baseline clinical, biochemical evaluation and were reassessed at 3 and 6 months for evaluating the clinical status for possible documentation of cure. The cure rate was 61.1% in drug naive group and 58.8% in pretreated group at 6 months following radioiodine (P = 0.845). Higher baseline 999m technicium (99m Tc) uptake, male gender, BMI and higher baseline free thyroxine (fT4) level predicted treatment failure following radioiodine therapy. Administration of carbimazole prior to low dose radioiodine therapy does not alter the efficacy of radioiodine. Low fixed dose (5 mCi) of radioactive iodine may be a safe and effective primary therapeutic option in Graves' disease patients pretreated with antithyroid drugs.

  13. Radon intercomparisons at EML, January 1983 and February 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisenne, I.M.; George, A.C.; Keller, H.W.

    1985-02-01

    This report summarizes the results of two radon measurement intercomparison exercises held at the Environmental Measurements Laboratory (EML) in January 1983 and February 1984. Nineteen organizations, including five US federal facilities, one national laboratory, two state laboratories, six universities, three private sector laboratories and two non-US facilities participated in these exercises. The results indicate good agreement among the participants at /sup 222/Rn concentration levels of 50 and 80 pCi.L/sup -1/. Improvements in the EML calibration facilities, and the participation of two US laboratories in a Nuclear Energy Agency intercomparison program are also discussed. 8 references, 6 figures, 8 tables.

  14. Pilocarpine effect on dose rate of salivary gland in differentiated thyroid carcinoma patients treated with radioiodine.

    PubMed

    Haghighatafshar, Mahdi; Ghaedian, Mehrnaz; Etemadi, Zahra; Entezarmahdi, Seyed M; Ghaedian, Tahereh

    2018-05-01

    Although different methods have been suggested on reducing salivary gland radiation after radioiodine administration, an effective preventive or therapeutic measure is still up for debate. The aim of this study was to evaluate the effect of pilocarpine, as a sialagogue drug on the radioiodine content of the salivary gland, and radioiodine-induced symptoms of salivary gland dysfunction. Patients who were referred for radioiodine therapy were randomized into pilocarpine and placebo groups. The patients as well as the nurse who administered the tablets, and the specialist who analyzed the images, were all unaware of the patients' group. Anterior and posterior planar images including that of both the head and neck were obtained 2, 6, 12, 24, and 48 h after the administration of radioiodine in all patients, and round regions of interest were drawn for both left and right parotid glands, with a rectangular region of interest in the region of the cerebrum as background. All patients were interrogated once, 6 months after radioiodine administration, by a phone call for subjective evaluation of symptoms related to salivary gland damage. There was no significant difference between the two groups with regard to the mean age, sex, and initial iodine activity. The geometric mean of background-corrected count per administered dose and acquisition time was calculated for the bilateral parotid glands. This normalized parotid count showed a significant reduction in net parotid count in both groups during the first 48 h after radioiodine administration. However, no significant difference was found between the groups according to the amount and pattern of dose reduction in this time period. This study revealed that pilocarpine had no significant effect on the radioiodine content of parotid glands during the first 48 h after radioiodine administration. No significant difference was found in the incidence of symptoms between the two groups treated with placebo and pilocarpine.

  15. Local reactions to radioiodine in the treatment of thyroid cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burmeister, L.A.; du Cret, R.P.; Mariash, C.N.

    1991-02-01

    The purpose of this study is to compare the rate of local complications resulting from radioiodine ablation of thyroid cancer in patients with a residual intact thyroid lobe to that in patients who had more extensive surgical treatment prior to radioiodine administration. We retrospectively studied 59 patients who had received 131I between 1979 and 1989. The patients were divided into two groups, depending on the extent of their previous surgical thyroid excision. Group 1 comprised 10 patients with a lobectomy or hemithyroidectomy before the ablative radioiodine dose, and Group 2 comprised 49 patients with more extensive thyroid excision (near-total ormore » subtotal thyroidectomy) before the radioiodine treatment. Sixty percent of the 10 patients in Group 1 experienced some degree of neck pain or tenderness following radioiodine ablation of their residual thyroid. In one case, the local reaction was very severe and accompanied by the development of transient hyperthyroidism. There was only a 6% local complication rate in the patients who had undergone more extensive thyroid excision before ablative therapy (p less than 0.001), and none had a severe reaction. Patients with only unilateral surgical excision before radioiodine therapy have a higher rate of local complications than do patients treated with more extensive surgery prior to radioiodine ablation. If radioiodine is to be employed in such patients, they should be informed of this possible complication. Since evidence supports a dose effect in the pathogenesis of the complications, we recommend using a dose of less than 30 mCi for the initial ablation in these patients even though it may be necessary to repeat this dose to complete thyroid ablation.« less

  16. [Graves' disease nd toxic nodular goiter--radioiodine therapy].

    PubMed

    Schicha, H; Dietlein, M

    2002-04-01

    At the 15th conference on the human thyroid in Heidelberg in 2001 the following aspects of the radioiodine therapy of benign thyroid disorders were presented: General strategies for therapy of benign thyroid diseases, criterions for conservative or definitive treatment of hyperthyroidism as first line therapy and finally preparation, procedural details, results, side effects, costs and follow-up care of radioiodine therapy as well as legal guidelines for hospitalization in Germany. The diagnosis Graves' hyperthyroidism needs the decision, if rather a conservative treatment or if primary radioiodine therapy is the best therapeutic approach. In the USA 70-90% of these patients are treated with radioiodine as first line therapy, whereas in Germany the conservative therapy for 1-1.5 years is recommended for 90%. This review describes subgroups of patients with Graves' disease showing a higher probability to relapse after conservative treatment. Comparing benefits, adverse effects, costs, and conveniences of both treatment strategies the authors conclude that radioiodine therapy should be preferred as first line therapy in 60-70% of the patients with Graves' hyperthyroidism.

  17. Variants and pitfalls on radioiodine scans in pediatric patients with differentiated thyroid carcinoma.

    PubMed

    Mostafa, Mohamed; Vali, Reza; Chan, Jeffrey; Omarkhail, Yusuaf; Shammas, Amer

    2016-10-01

    Potentially false-positive findings on radioiodine scans in children with differentiated thyroid carcinoma can mimic functioning thyroid tissue and functioning thyroid carcinomatous tissue. Such false-positive findings comprise variants and pitfalls that can vary slightly in children as compared with adults. To determine the patterns and frequency of these potential false-positive findings on radioiodine scans in children with differentiated thyroid carcinoma. We reviewed a total of 223 radioiodine scans from 53 pediatric patients (mean age 13.3 years, 37 girls) with differentiated thyroid carcinoma. Focal or regional activity that likely did not represent functioning thyroid tissue or functioning thyroid carcinomatous tissue were categorized as variants or pitfalls. The final diagnosis was confirmed by reviewing the concurrent and follow-up clinical data, correlative ultrasonography, CT scanning, serum thyroglobulin and antithyroglobulin antibody levels. We calculated the frequency of these variants and pitfalls from diagnostic and post-therapy radioiodine scans. The most common variant on the radioiodine scans was the thymic activity (24/223, 10.8%) followed by the cardiac activity (8/223, 3.6%). Salivary contamination and star artifact, caused by prominent thyroid remnant, were the most important observed pitfalls. Variants and pitfalls that mimic functioning thyroid tissue or functioning thyroid carcinomatous tissue on radioiodine scan in children with differentiated thyroid carcinoma are not infrequent, but they decrease in frequency on successive radioiodine scans. Potential false-positive findings can be minimized with proper knowledge of the common variants and pitfalls in children and correlation with clinical, laboratory and imaging data.

  18. The impurity of radioiodinated triolein

    PubMed Central

    Kennedy, J. A.; Kinloch, J. D.

    1964-01-01

    Commercially supplied radioiodinated triolein has been shown by thin-layer chromatography and silicic acid column chromatography to contain impurities, consisting mainly of diglycerides and monoglycerides, but also a small amount of free fatty acid. The effect of these impurities on the radioiodinated triolein absorption test requires further investigation. Images PMID:14149942

  19. Radioiodine therapy versus antithyroid drugs in Graves' disease: a meta-analysis of randomized controlled trials.

    PubMed

    Wang, Junqi; Qin, Lan

    2016-06-27

    This meta-analysis was performed to compare radioiodine therapy with antithyroid drugs in terms of clinical outcomes, including development or worsening of ophthalmopathy, hyperthyroid cure rate, hypothyroidism, relapse rate and adverse events. Randomized controlled trials (RCTs) published in PubMed, Embase, Web of Science, SinoMed and National Knowledge Infrastructure, China, were systematically reviewed to compare the effects of radioiodine therapy with antithyroid drugs in patients with Graves' disease. Results were expressed as risk ratio with 95% confidence intervals (CIs) and weighted mean differences with 95% CIs. Pooled estimates were performed using a fixed-effects model or random-effects model, depending on the heterogeneity among studies. 17 RCTs involving 4024 patients met the inclusion criteria and were included. Results showed that radioiodine treatment has increased risk in new ophthalmopathy, development or worsening of ophthalmopathy and hypothyroidism. Whereas, compared with antithyroid drugs, radioiodine treatment seems to have a higher hyperthyroid cure rate, lower recurrence rate and lower incidence of adverse events. Radioiodine therapy is associated with a higher hyperthyroid cure rate and lower relapse rate compared with antithyroid drugs. However, it also increases the risk of ophthalmopathy and hypothyroidism. Considering that antithyroid drug treatment can be associated with unsatisfactory control of hyperthyroidism, we would recommend radioiodine therapy as the treatment of choice for patients with Graves' disease.

  20. Effects of antithyroid drugs on radioiodine treatment: systematic review and meta-analysis of randomised controlled trials.

    PubMed

    Walter, Martin A; Briel, Matthias; Christ-Crain, Mirjam; Bonnema, Steen J; Connell, John; Cooper, David S; Bucher, Heiner C; Müller-Brand, Jan; Müller, Beat

    2007-03-10

    To determine the effect of adjunctive antithyroid drugs on the risk of treatment failure, hypothyroidism, and adverse events after radioiodine treatment. Meta-analysis. Electronic databases (Cochrane central register of controlled trials, Medline, Embase) searched to August 2006 and contact with experts. Review methods Three reviewers independently assessed trial eligibility and quality. Pooled relative risks for treatment failure and hypothyroidism after radioiodine treatment with and without adjunctive antithyroid drugs were calculated with a random effects model. We identified 14 relevant randomised controlled trials with a total of 1306 participants. Adjunctive antithyroid medication was associated with an increased risk of treatment failure (relative risk 1.28, 95% confidence interval 1.07 to 1.52; P=0.006) and a reduced risk for hypothyroidism (0.68, 0.53 to 0.87; P=0.006) after radioiodine treatment. We found no difference in summary estimates for the different antithyroid drugs or for whether antithyroid drugs were given before or after radioiodine treatment. Antithyroid drugs potentially increase rates of failure and reduce rates of hypothyroidism if they are given in the week before or after radioiodine treatment, respectively.

  1. Radioiodine therapy versus antithyroid drugs in Graves' disease: a meta-analysis of randomized controlled trials

    PubMed Central

    Qin, Lan

    2016-01-01

    Objective: This meta-analysis was performed to compare radioiodine therapy with antithyroid drugs in terms of clinical outcomes, including development or worsening of ophthalmopathy, hyperthyroid cure rate, hypothyroidism, relapse rate and adverse events. Methods: Randomized controlled trials (RCTs) published in PubMed, Embase, Web of Science, SinoMed and National Knowledge Infrastructure, China, were systematically reviewed to compare the effects of radioiodine therapy with antithyroid drugs in patients with Graves' disease. Results were expressed as risk ratio with 95% confidence intervals (CIs) and weighted mean differences with 95% CIs. Pooled estimates were performed using a fixed-effects model or random-effects model, depending on the heterogeneity among studies. Results: 17 RCTs involving 4024 patients met the inclusion criteria and were included. Results showed that radioiodine treatment has increased risk in new ophthalmopathy, development or worsening of ophthalmopathy and hypothyroidism. Whereas, compared with antithyroid drugs, radioiodine treatment seems to have a higher hyperthyroid cure rate, lower recurrence rate and lower incidence of adverse events. Conclusion: Radioiodine therapy is associated with a higher hyperthyroid cure rate and lower relapse rate compared with antithyroid drugs. However, it also increases the risk of ophthalmopathy and hypothyroidism. Advances in knowledge: Considering that antithyroid drug treatment can be associated with unsatisfactory control of hyperthyroidism, we would recommend radioiodine therapy as the treatment of choice for patients with Graves' disease. PMID:27266544

  2. An intercomparison of carbon monoxide, nitric oxide, and hydroxyl measurement techniques - Overview of results

    NASA Technical Reports Server (NTRS)

    Hoell, J. M.; Gregory, G. L.; Carroll, M. A.; Mcfarland, M.; Ridley, B. A.; Davis, D. D.; Bradshaw, J.; Rodgers, M. O.; Torres, A. L.; Condon, E. P.

    1984-01-01

    Results from an intercomparison of methods to measure carbon monoxide (CO), nitric oxide (NO), and the hydroxyl radical (OH) are discussed. The intercomparison was conducted at Wallops Island, Virginia, in July 1983 and included a laser differential absorption and three grab sample/gas chromatograph methods for CO, a laser-induced fluorescence (LIF) and two chemiluminescence methods for NO, and two LIF methods and a radiocarbon tracer method for OH. The intercomparison was conducted as a field measurement program involving ambient measurements of CO (150-300 ppbv) and NO (10-180 pptv) from a common manifold with controlled injection of CO in incremental steps from 20 to 500 ppbv and NO in steps from 10 to 220 pptv. Only ambient measurements of OH were made. The agreement between the techniques was on the order of 14 percent for CO and 17 percent for NO. Hardware difficulties during the OH tests resulted in a data base with insufficient data and uncertanties too large to permit a meaningful intercomposition.

  3. Radioiodine therapy versus antithyroid medications for Graves' disease.

    PubMed

    Ma, Chao; Xie, Jiawei; Wang, Hui; Li, Jinsong; Chen, Suyun

    2016-02-18

    Graves' disease is the most common cause of hyperthyroidism. Both antithyroid medications and radioiodine are commonly used treatments but their frequency of use varies between regions and countries. Despite the commonness of the diagnosis, any possible differences between the two treatments with respect to long-term outcomes remain unknown. To assess the effects of radioiodine therapy versus antithyroid medications for Graves' disease. We performed a systematic literature search in the Cochrane Library, MEDLINE and EMBASE and the trials registers ICTRP Search Portal and ClinicalTrials.gov. The date of the last search was September 2015 for all databases. Randomised controlled trials (RCTs) comparing the effects of radioiodine therapy versus antithyroid medications for Graves' disease with at least two years follow-up. Two authors independently screened titles and abstracts for relevance. One author carried out screening for inclusion, data extraction and 'Risk of bias' assessment and a second author checked this. We presented data not suitable for meta-analysis as descriptive data. We analysed the overall quality of evidence utilising the GRADE instrument. We included two RCTs involving 425 adult participants with Graves' disease in this review. Altogether 204 participants were randomised to radioiodine therapy and 221 to methimazole therapy. A single dose of radioiodine was administered. The duration of methimazole medication was 18 months. The period of follow-up was at least two years, depending on the outcome measured. For most outcome measures risk of bias was low; for the outcomes health-related quality of life as well as development and worsening of Graves' ophthalmopathy risks of performance bias and detection bias were high in at least one of the two RCTs.Health-related quality of life appeared to be similar in the radioiodine and methimazole treatment groups, however no quantitative data were reported (425 participants; 2 trials; low quality evidence). The development and worsening of Graves' ophthalmopathy was observed in 76 of 202 radioiodine-treated participants (38%) and in 40 of 215 methimazole-treated participants (19%): risk ratio (RR) 1.94 (95% confidence interval (CI) 1.40 to 2.70); 417 participants; 2 trials; low quality evidence. A total of 35% to 56% of radioiodine-treated participants and 42% of participants treated with methimazole were smokers, which is associated with the risk of worsening or development of Graves' ophthalmopathy. Euthyroidism was not achieved by any participant being treated with radioiodine compared with 64/68 (94%) of participants after methimazole treatment (112 participants; 1 trial). In this trial thyroxine therapy was not introduced early in both treatment arms to avoid hypothyroidism. Recurrence of hyperthyroidism (relapse) in favour of radioiodine treatment showed a RR of 0.20 (95% CI 0.01 to 2.66); P value = 0.22; 417 participants; 2 trials; very low quality evidence. Heterogeneity was high (I² = 91%) and the RRs were 0.61 or 0.06 with non-overlapping CIs. Adverse events other than development of worsening of Graves' ophthalmopathy for radioiodine therapy were hypothyroidism (39 of 41 participants (95%) compared with 0% of participants receiving methimazole, however thyroxine treatment to avoid hypothyroidism was not introduced early in the radioiodine group - 104 participants; 1 trial; very low quality evidence) and drug-related adverse events for methimazole treatment (23 of 215 participants (11%) reported adverse effects likely related to methimazole therapy - 215 participants; 2 trials; very low quality evidence). The outcome measures all-cause mortality and bone mineral density were not reported in the included trials. One trial (174 participants) reported socioeconomic effects: costs based on the official hospital reimbursement system in Sweden for patients without relapse and methimazole treatment were USD 1126/1164 (young/older methimazole group) and for radioiodine treatment USD 1862. Costs for patients with relapse and methimazole treatment were USD 2284/1972 (young/older methimazole group) and for radioiodine treatment USD 2760. The only antithyroid drug investigated in the two included trials was methimazole, which might limit the applicability of our findings with regard to other compounds such as propylthiouracil. Results from two RCTs suggest that radioiodine treatment is associated with an increased risk of Graves' ophthalmopathy. Our findings suggest some benefit from radioiodine treatment for recurrence of hyperthyroidism (relapse) but there is uncertainty about the magnitude of the effect size.

  4. Calculation of Blood Dose in Patients Treated With 131I Using MIRD, Imaging, and Blood Sampling Methods

    PubMed Central

    Piruzan, Elham; Haghighatafshar, Mahdi; Faghihi, Reza; Entezarmahdi, Seyed Mohammad

    2016-01-01

    Abstract Radioiodine therapy is known as the most effective treatment of differentiated thyroid carcinoma (DTC) to ablate remnant thyroid tissue after surgery. In patients with DTC treated with radioiodine, internal radiation dosimetry of radioiodine is useful for radiation risk assessment. The aim of this study is to describe a method to estimate the absorbed dose to the blood using medical internal radiation dosimetry methods. In this study, 23 patients with DTC with different administrated activities, 3.7, 4.62, and 5.55 GBq after thyroidectomy, were randomly selected. Blood dosimetry of treated patients was performed with external whole body counting using a dual-head gamma camera imaging device and also with blood sample activity measurements using a dose calibrator. Absorbed dose to the blood was measured at 2, 6, 12, 24, 48, and 96 hours after the administration of radioiodine with the 2 methods. Based on the results of whole body counting and blood sample activity dose rate measurements, 96 hours after administration of 3.7, 4.62, and 5.55 GBq of radioiodine, absorbed doses to patients’ blood were 0.65 ± 0.20, 0.67 ± 0.18, 0.79 ± 0.51 Gy, respectively. Increasing radioiodine activity from 3.7 to 5.55 GBq increased blood dose significantly, while there was no significant difference in blood dose between radioiodine dosages of 3.7 and 4.62 GBq. Our results revealed a significant correlation between the blood absorbed dose and blood sample activity and between the blood absorbed dose and whole body counts 24 to 48 hours after the administration of radioiodine. PMID:26986171

  5. Calculation of Blood Dose in Patients Treated With 131I Using MIRD, Imaging, and Blood Sampling Methods.

    PubMed

    Piruzan, Elham; Haghighatafshar, Mahdi; Faghihi, Reza; Entezarmahdi, Seyed Mohammad

    2016-03-01

    Radioiodine therapy is known as the most effective treatment of differentiated thyroid carcinoma (DTC) to ablate remnant thyroid tissue after surgery. In patients with DTC treated with radioiodine, internal radiation dosimetry of radioiodine is useful for radiation risk assessment. The aim of this study is to describe a method to estimate the absorbed dose to the blood using medical internal radiation dosimetry methods. In this study, 23 patients with DTC with different administrated activities, 3.7, 4.62, and 5.55 GBq after thyroidectomy, were randomly selected. Blood dosimetry of treated patients was performed with external whole body counting using a dual-head gamma camera imaging device and also with blood sample activity measurements using a dose calibrator. Absorbed dose to the blood was measured at 2, 6, 12, 24, 48, and 96 hours after the administration of radioiodine with the 2 methods. Based on the results of whole body counting and blood sample activity dose rate measurements, 96 hours after administration of 3.7, 4.62, and 5.55 GBq of radioiodine, absorbed doses to patients' blood were 0.65 ± 0.20, 0.67 ± 0.18, 0.79 ± 0.51 Gy, respectively. Increasing radioiodine activity from 3.7 to 5.55 GBq increased blood dose significantly, while there was no significant difference in blood dose between radioiodine dosages of 3.7 and 4.62 GBq. Our results revealed a significant correlation between the blood absorbed dose and blood sample activity and between the blood absorbed dose and whole body counts 24 to 48 hours after the administration of radioiodine.

  6. Effects of antithyroid drugs on radioiodine treatment: systematic review and meta-analysis of randomised controlled trials

    PubMed Central

    Briel, Matthias; Christ-Crain, Mirjam; Bonnema, Steen J; Connell, John; Cooper, David S; Bucher, Heiner C; Müller-Brand, Jan; Müller, Beat

    2007-01-01

    Objective To determine the effect of adjunctive antithyroid drugs on the risk of treatment failure, hypothyroidism, and adverse events after radioiodine treatment. Design Meta-analysis. Data sources Electronic databases (Cochrane central register of controlled trials, Medline, Embase) searched to August 2006 and contact with experts. Review methods Three reviewers independently assessed trial eligibility and quality. Pooled relative risks for treatment failure and hypothyroidism after radioiodine treatment with and without adjunctive antithyroid drugs were calculated with a random effects model. Results We identified 14 relevant randomised controlled trials with a total of 1306 participants. Adjunctive antithyroid medication was associated with an increased risk of treatment failure (relative risk 1.28, 95% confidence interval 1.07 to 1.52; P=0.006) and a reduced risk for hypothyroidism (0.68, 0.53 to 0.87; P=0.006) after radioiodine treatment. We found no difference in summary estimates for the different antithyroid drugs or for whether antithyroid drugs were given before or after radioiodine treatment. Conclusions Antithyroid drugs potentially increase rates of failure and reduce rates of hypothyroidism if they are given in the week before or after radioiodine treatment, respectively. PMID:17309884

  7. A prospective study of the effects of radioiodine therapy for hyperthyroidism in patients with minimally active graves' ophthalmopathy.

    PubMed

    Perros, Petros; Kendall-Taylor, Pat; Neoh, Chris; Frewin, Sarah; Dickinson, Jane

    2005-09-01

    Radioiodine is an effective and safe treatment for hyperthyroidism but has been implicated as a risk factor for deterioration or new presentation of Graves' ophthalmopathy (GO). Prophylactic glucocorticoids appear to prevent this effect. The objective of this study was to document the course of GO after radioiodine therapy. This was a prospective observational study. Patients were assessed at baseline and 2, 4, 6, and 12 months after radioiodine therapy. The study was conducted at a tertiary referral center. Seventy-two GO patients with minimally active eye disease participated in the study. A fixed dose of radioiodine was administered. T(4) was commenced 2 wk later to prevent hypothyroidism. Change in activity and severity of GO were analyzed. Exophthalmometer readings, the width of the palpebral aperture, diplopia scores, and the clinical activity score improved significantly. By clinically significant criteria, the eye disease improved in four patients (transiently in three of the four cases), most likely attributable to the natural course of the disease. No patient's eyes deteriorated. Radioiodine is not associated with deterioration of GO in patients with minimally active eye disease when postradioiodine hypothyroidism is prevented.

  8. Personalized Medicine Based on Theranostic Radioiodine Molecular Imaging for Differentiated Thyroid Cancer.

    PubMed

    Ahn, Byeong-Cheol

    2016-01-01

    Molecular imaging based personalized therapy has been a fascinating concept for individualized therapeutic strategy, which is able to attain the highest efficacy and reduce adverse effects in certain patients. Theranostics, which integrates diagnostic testing to detect molecular targets for particular therapeutic modalities, is one of the key technologies that contribute to the success of personalized medicine. Although the term "theranostics" was used after the second millennium, its basic principle was applied more than 70 years ago in the field of thyroidology with radioiodine molecular imaging. Differentiated thyroid cancer, which arises from follicular cells in the thyroid, is the most common endocrine malignancy, and theranostic radioiodine has been successfully applied to diagnose and treat differentiated thyroid cancer, the applications of which were included in the guidelines published by various thyroid or nuclear medicine societies. Through better pathophysiologic understanding of thyroid cancer and advancements in nuclear technologies, theranostic radioiodine contributes more to modern tailored personalized management by providing high therapeutic effect and by avoiding significant adverse effects in differentiated thyroid cancer. This review details the inception of theranostic radioiodine and recent radioiodine applications for differentiated thyroid cancer management as a prototype of personalized medicine based on molecular imaging.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahren, B.

    The thyroid gland is known to harbor cholinergic and VIPergic nerves. In the present study, the influences of cholinergic stimulation by carbachol, cholinergic blockade by methylatropine and stimulation with various VIP sequences on basal, TSH-induced and VIP-induced thyroid hormone secretion were investigated in vivo in mice. The mice were pretreated with /sup 125/I and thyroxine; the subsequent release of /sup 125/I is an estimation of thyroid hormone secretion. It was found that basal radioiodine secretion was inhibited by both carbachol and methylatropine. Furthermore, TSH-induced radioiodine secretion was inhibited already by a low dose of carbachol. Moreover, a high dose ofmore » carbachol could inhibit VIP-induced radioiodine secretion. Methylatropine did not influence TSH- or VIP-stimulated radioiodine secretion, but counteracted the inhibitory action of carbachol on TSH- and VIP-induced radioiodine release. In addition, contrary to VIP, six various synthesized VIP fragments had no effect on basal or stimulated radioiodine release. It is concluded that basal thyroid hormone secretion is inhibited by both cholinergic activation and blockade. Furthermore, TSH-induced thyroid hormone secretion is more sensitive to inhibition with cholinergic stimulation than is VIP-induced thyroid hormone secretion. In addition, the VIP stimulation of thyroid hormone secretion seems to require the full VIP sequence.« less

  10. Effect of a Low Iodine Diet vs. Restricted Iodine Diet on Postsurgical Preparation for Radioiodine Ablation Therapy in Thyroid Carcinoma Patients.

    PubMed

    Lim, Chi Young; Kim, Jung-Yeon; Yoon, Mi-Jin; Chang, Hang Seok; Park, Cheong Soo; Chung, Woong Youn

    2015-07-01

    The radioiodine ablation therapy is required for patients who underwent a total thyroidectomy. Through a comparative review of a low iodine diet (LID) and a restricted iodine diet (RID), the study aims to suggest guidelines that are suitable for the conditions of Korea. The study was conducted with 101 patients. With 24-hour urine samples from the patients after a 2-week restricted diet and after a 4-week restricted diet, the amount of iodine in the urine was estimated. The consumed radioiodine amounts for 2 hours and 24 hours were calculated. This study was conducted with 47 LID patients and 54 RID patients. The amounts of iodine in urine, the 2-week case and 4-week case for each group showed no significant differences. The amounts of iodine in urine between the two groups were both included in the range of the criteria for radioiodine ablation therapy. Also, 2 hours and 24 hours radioiodine consumption measured after 4-week restrictive diet did not show statistical differences between two groups. A 2-week RID can be considered as a type of radioiodine ablation therapy after patients undergo a total thyroidectomy.

  11. Radioiodine in the Savannah River Site environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kantelo, M.V.; Bauer, L.R.; Marter, W.L.

    1993-01-15

    Radioiodine, which is the collective term for all radioactive isotopes of the element iodine, is formed at the Savannah River Site (SRS) principally as a by-product of nuclear reactor operations. Part of the radioiodine is released to the environment during reactor and reprocessing operations at the site. The purpose of this report is to provide an introduction to radioiodine production and disposition, its status in the environment, and the radiation dose and health risks as a consequence of its release to the environment around the Savannah River Plant. A rigorous dose reconstruction study is to be completed by thee Centermore » for Disease Control during the 1990s.« less

  12. Effect of a Low Iodine Diet vs. Restricted Iodine Diet on Postsurgical Preparation for Radioiodine Ablation Therapy in Thyroid Carcinoma Patients

    PubMed Central

    Lim, Chi Young; Kim, Jung-Yeon; Yoon, Mi-Jin; Chang, Hang Seok; Park, Cheong Soo

    2015-01-01

    Purpose The radioiodine ablation therapy is required for patients who underwent a total thyroidectomy. Through a comparative review of a low iodine diet (LID) and a restricted iodine diet (RID), the study aims to suggest guidelines that are suitable for the conditions of Korea. Materials and Methods The study was conducted with 101 patients. With 24-hour urine samples from the patients after a 2-week restricted diet and after a 4-week restricted diet, the amount of iodine in the urine was estimated. The consumed radioiodine amounts for 2 hours and 24 hours were calculated. Results This study was conducted with 47 LID patients and 54 RID patients. The amounts of iodine in urine, the 2-week case and 4-week case for each group showed no significant differences. The amounts of iodine in urine between the two groups were both included in the range of the criteria for radioiodine ablation therapy. Also, 2 hours and 24 hours radioiodine consumption measured after 4-week restrictive diet did not show statistical differences between two groups. Conclusion A 2-week RID can be considered as a type of radioiodine ablation therapy after patients undergo a total thyroidectomy. PMID:26069126

  13. Radioiodination of chicken luteinizing hormone without affecting receptor binding potency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kikuchi, M.; Ishii, S.

    1989-12-01

    By improving the currently used lactoperoxidase method, we were able to obtain radioiodinated chicken luteinizing hormone (LH) that shows high specific binding and low nonspecific binding to a crude plasma membrane fraction of testicular cells of the domestic fowl and the Japanese quail, and to the ovarian granulosa cells of the Japanese quail. The change we made from the original method consisted of (1) using chicken LH for radioiodination that was not only highly purified but also retained a high receptor binding potency; (2) controlling the level of incorporation of radioiodine into chicken LH molecules by employing a short reactionmore » time and low temperature; and (3) fractionating radioiodinated chicken LH further by gel filtration using high-performance liquid chromatography. Specific radioactivity of the final {sup 125}I-labeled chicken LH preparation was 14 microCi/micrograms. When specific binding was 12-16%, nonspecific binding was as low as 2-4% in the gonadal receptors. {sup 125}I-Labeled chicken LH was displaced by chicken LH and ovine LH but not by chicken follicle-stimulating hormone. The equilibrium association constant of quail testicular receptor was 3.6 x 10(9) M-1. We concluded that chicken LH radioiodinated by the present method is useful for studies of avian LH receptors.« less

  14. Gastrointestinal Side Effects of the Radioiodine Therapy for the Patients with Differentiated Thyroid Carcinoma Two Days after Prescription.

    PubMed

    Pashnehsaz, Mehran; Takavar, Abbas; Izadyar, Sina; Zakariaee, Seyed Salman; Mahmoudi, Mahmoud; Paydar, Reza; Geramifar, Parham

    2016-09-01

    Iodine-131 (I-131) therapy is one of the conventional approaches in the treatment of patients with differentiated thyroid carcinoma (DTC). The radioiodine agents also accumulate in the other organs that cause pain and damage to the patients. Radioiodine therapy is associated with various gastrointestinal (GI) toxicities. In this study, GI side effects of the radioiodine therapy were investigated. GI toxicities of the radioiodine therapy were studied in 137 patients with histologically proven DTC in Jun-Nov 2014. All the patients were treated by radioiodine agents in the research institute of Shariati Hospital, Tehran, Iran. The patients were examined 48 h after prescription (before discharge) and their GI side effects were registered. Correlation of the age, gender, administered dose, administered dose per body weight as the independent factors, and GI side effects were analyzed using the Pearson correlation test with Statistical Package for the Social Sciences (SPSS) version 20. Regression coefficients and linearity of the variable were investigated by MATLAB software. Line fitting was performed using MATLAB curve-fitting toolbox. From the subjects, 38 patients had GI complaints (30.4%). Significant factors influencing GI side effects were dose per body weight and administered doses. There was no significant correlation between age and gender as the independent parameters and GI complaints. The most prevalent GI side effect was nausea that occurs in 26.4% of the patients. From the results, it could be concluded that the GI side effects could be prevented by administering a safe radioiodine dose value less than 5,550 MBq.

  15. [Radioiodine 131I therapy of hyperthyroidism on an outpatient basis - safe, effective and economic option].

    PubMed

    Jiskra, J; Kubinyi, J; Telička, Z

    2012-02-01

    Radioiodine 131I therapy of hyperthyroidism on an outpatient basis is widely accepted over the world. In Czech Republic, however, radioiodine therapy is still not enough used, and has been realized on an inpatient basis to date. Our work is the first analysis of the experiences with radioiodine therapy of hyperthyroidism on an outpatient basis in Czech Republic. Capsule with 550 MBq of 131I was administered orally in 39 hyperthyroid patients (32 women and 8 men, 21 with autoimmune Graves hyperthyroidism and 18 with toxic thyroid nodules, mean age 66.8 years). In 32 of them we evaluated effectiveness and complications of therapy after 12-42 months. We also compared financial costs of the radioiodine treatment on an outpatient basis with the treatment in hospitalization and with surgery. After the treatment, 9/32 (28 %) patients were euthyroid without thyrostatic/thyroxine treatment, 18/32 (60 %) patients were hypothyroid with thyroxine therapy, 2/32 (6 %) patients significantly decreased doses of thyrostatic drugs. In 2/32 (6 %) patients the treatment was ineffective. The effect of the treatment did not depend on the etiology and severity of hyperthyroidism, but decreased with thyroid volume. Patients with ineffective or only partially effective treatment had median of thyroid volume more than 40 ml. In 1 patient thyroid associated ophthalmopathy was moderately worsened. Other complications were not observed. If we compared financial costs in model with 1 patient, we found that the costs of radioiodine therapy on an outpatient basis (118.7 €) comprise only 16 % of the costs of radioiodine therapy in hospitalization (728 €) and only 25 % of the costs of surgery (475.6 €). Radioiodine 131I is effective and safe in the treatment of hyperthyroidism and the therapy on an outpatient basis is much cheaper choice. The therapy with 131I on an outpatient basis is not suitable in patients with thyroid volume more than 40 ml.

  16. Emergency radiobioassay preparedness exercises through the NIST radiochemistry intercomparison program.

    PubMed

    Nour, Svetlana; LaRosa, Jerry; Inn, Kenneth G W

    2011-08-01

    The present challenge for the international emergency radiobioassay community is to analyze contaminated samples rapidly while maintaining high quality results. The National Institute of Standards and Technology (NIST) runs a radiobioassay measurement traceability testing program to evaluate the radioanalytical capabilities of participating laboratories. The NIST Radiochemistry Intercomparison Program (NRIP) started more than 10 years ago, and emergency performance testing was added to the program seven years ago. Radiobioassay turnaround times under the NRIP program for routine production and under emergency response scenarios are 60 d and 8 h, respectively. Because measurement accuracy and sample turnaround time are very critical in a radiological emergency, response laboratories' analytical systems are best evaluated and improved through traceable Performance Testing (PT) programs. The NRIP provides participant laboratories with metrology tools to evaluate their performance and to improve it. The program motivates the laboratories to optimize their methodologies and minimize the turnaround time of their results. Likewise, NIST has to make adjustments and periodical changes in the bioassay test samples in order to challenge the participating laboratories continually. With practice, radioanalytical measurements turnaround time can be reduced to 3-4 h.

  17. Development of Tethered Hsp90 Inhibitors Carrying Radioiodinated Probes to Specifically Discriminate and Kill Malignant Breast Tumor Cells

    DTIC Science & Technology

    2016-05-01

    AWARD NUMBER: W81XWH-15-1-0072 TITLE: Development of Tethered Hsp90 Inhibitors Carrying Radioiodinated Probes to Specifically Discriminate and...1 May 2015 - 30 Apr 2016 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Development of Tethered Hsp90 Inhibitors Carrying Radioiodinated Probes to...inhibitor capable of carrying various radioactive iodine isotopes for early detection and ablation of metastatic breast cancers. These probes

  18. Effects of drugs on the efficacy of radioiodine (|) therapy in hyperthyroid patients.

    PubMed

    Oszukowska, Lidia; Knapska-Kucharska, Małgorzata; Lewiński, Andrzej

    2010-03-01

    The treatment of hyperthyroidism is targeted at reducing the production of thyroid hormones by inhibiting their synthesis or suppressing their release, as well as by controlling their influence on peripheral tissue (conservative therapy, medical treatment). Radical treatment includes surgical intervention to reduce the volume of thyroid tissue or damage of the mechanisms of thyroid hormone synthesis by radioiodine ((131)|) administration. Radioiodine ((131)|) is a reactor radionuclide, produced as a result of uranium decomposition and emission of β and γ radiation. The therapeutic effects of the isotope are obtained by the emission of β radiation. In the paper, the effects of administered drugs (antithyroid, glucocorticosteroids, lithium carbonate, inorganic iodine, β-blockers) on the final outcome of radioiodine therapy in patients with hyperthyroidism are discussed.

  19. Improved iodine radiolabels for monoclonal antibody therapy.

    PubMed

    Stein, Rhona; Govindan, Serengulam V; Mattes, M Jules; Chen, Susan; Reed, Linda; Newsome, Guy; McBride, Bill J; Griffiths, Gary L; Hansen, Hans J; Goldenberg, David M

    2003-01-01

    A major disadvantage of (131)iodine (I)-labeled monoclonal antibodies (MAbs) for radioimmunotherapy has been the rapid diffusion of iodotyrosine from target cells after internalization and catabolism of the radioiodinated MAbs. We recently reported that a radioiodinated, diethylenetriaminepentaacetic acid-appended peptide, designated immunomedics' residualizing peptide 1 (IMP-R1), was a residualizing iodine label that overcame many of the limitations that had impeded the development of residualizing iodine for clinical use. To determine the factors governing the therapeutic index of the labeled MAb, as well as the factors required for production of radioiodinated MAb in high yield and with high specific activity, variations in the peptide structure of IMP-R1 were evaluated. A series of radioiodinated, diethylenetriaminepentaacetic acid-appended peptide moieties (IMP-R1 through IMP-R8) that differed in overall hydrophilicity and charge were compared. Radioiodinations of the peptides followed by conjugations to disulfide-reduced RS7 (an anti-epithelial glycoprotein-1 MAb) furnished radioimmunoconjugates in good overall incorporations, with immunoreactivities comparable to that of directly radioiodinated RS7. Specific activities of up to 8 mCi/mg and yields > 80% have been achieved. In vitro processing experiments showed marked increases in radioiodine retention with all of the adducts; radioiodine retention at 45 h was up to 86% greater in cells than with directly iodinated RS7. Each of the (125)I-peptide-RS7 conjugates was compared with (131)I-RS7 (labeled by the chloramine-T method) in paired-label biodistribution studies in nude mice bearing human lung tumor xenografts. All of the residualizing substrates exhibited significantly enhanced retention in tumor in comparison to directly radioiodinated RS7, but the nontarget uptakes differed significantly among the residualizing labels. The best labels were IMP-R4 and IMP-R8, showing superior tumor-to-non-tumor ratios by virtue of high tumor uptake and retention and low normal organ uptake, as well as superior radiochemical properties. The therapeutic efficacy of (131)I-IMP-R4-RS7 was compared with that of conventionally (131)I-labeled RS7 and (90)yttrium-RS7 in the nude mice lung cancer model. The therapeutic efficacy of (131)I-IMP-R4-RS7 and (90)yttrium-RS7 were equivalent, and both agents yielded significantly improved control of tumor growth compared with conventional (131)I-labeled RS7.

  20. Peptide receptor radionuclide therapy of treatment-refractory metastatic thyroid cancer using 90Yttrium and 177Lutetium labeled somatostatin analogs: toxicity, response and survival analysis

    PubMed Central

    Budiawan, Hendra; Salavati, Ali; Kulkarni, Harshad R; Baum, Richard P

    2014-01-01

    The overall survival rate of non-radioiodine avid differentiated (follicular, papillary, medullary) thyroid carcinoma is significantly lower than for patients with iodine-avid lesions. The purpose of this study was to evaluate toxicity and efficacy (response and survival) of peptide receptor radionuclide therapy (PRRT) in non-radioiodine-avid or radioiodine therapy refractory thyroid cancer patients. Sixteen non-radioiodine-avid and/or radioiodine therapy refractory thyroid cancer patients, including follicular thyroid carcinoma (n = 4), medullary thyroid carcinoma (n = 8), Hürthle cell thyroid carcinoma (n = 3), and mixed carcinoma (n = 1) were treated with PRRT by using 90Yttrium and/or 177Lutetium labeled somatostatin analogs. 68Ga somatostatin receptor PET/CT was used to determine the somatostatin receptor density in the residual tumor/metastatic lesions and to assess the treatment response. Hematological profiles and renal function were periodically examined after treatment. By using fractionated regimen, only mild, reversible hematological toxicity (grade 1) or nephrotoxicity (grade 1) were seen. Response assessment (using EORTC criteria) was performed in 11 patients treated with 2 or more (maximum 5) cycles of PRRT and showed disease stabilization in 4 (36.4%) patients. Two patients (18.2%) showed partial remission, in the remaining 5 patients (45.5%) disease remained progressive. Kaplan-Meier analysis resulted in a mean survival after the first PRRT of 4.2 years (95% CI, range 2.9-5.5) and median progression free survival of 25 months (inter-quartiles: 12-43). In non-radioiodine-avid/radioiodine therapy refractory thyroid cancer patients, PRRT is a promising therapeutic option with minimal toxicity, good response rate and excellent survival benefits. PMID:24380044

  1. PNNL Results from 2010 CALIBAN Criticality Accident Dosimeter Intercomparison Exercise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hill, Robin L.; Conrady, Matthew M.

    2011-10-28

    This document reports the results of the Hanford personnel nuclear accident dosimeter (PNAD) and fixed nuclear accident dosimeter (FNAD) during a criticality accident dosimeter intercomparison exercise at the CEA Valduc Center on September 20-23, 2010. Pacific Northwest National Laboratory (PNNL) participated in a criticality accident dosimeter intercomparison exercise at the Commissariat a Energie Atomique (CEA) Valduc Center near Dijon, France on September 20-23, 2010. The intercomparison exercise was funded by the U.S. Department of Energy, Nuclear Criticality Safety Program, with Lawrence Livermore National Laboratory as the lead Laboratory. PNNL was one of six invited DOE Laboratory participants. The other participatingmore » Laboratories were: Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Savannah River Site (SRS), the Y-12 National Security Complex at Oak Ridge, and Sandia National Laboratory (SNL). The goals of PNNL's participation in the intercomparison exercise were to test and validate the procedures and algorithm currently used for the Hanford personnel nuclear accident dosimeters (PNADs) on the metallic reactor, CALIBAN, to test exposures to PNADs from the side and from behind a phantom, and to test PNADs that were taken from a historical batch of Hanford PNADs that had varying degrees of degradation of the bare indium foil. Similar testing of the PNADs was done on the Valduc SILENE test reactor in 2009 (Hill and Conrady, 2010). The CALIBAN results are reported here.« less

  2. Effects of hemodialysis on iodine-131 biokinetics in thyroid carcinoma patients with end-stage chronic renal failure.

    PubMed

    Yeyin, Nami; Cavdar, Iffet; Uslu, Lebriz; Abuqbeitah, Mohammad; Demir, Mustafa

    2016-03-01

    Radioiodine therapy could be challenging in chronic renal failure patients requiring hemodialysis. The aim of this study was to establish the effects of hemodialysis on elimination of radioiodine from the body in thyroid carcinoma patients with end-stage chronic renal failure and to determine its effects on environmental radiation dose. Three end-stage chronic renal failure patients (four cases) diagnosed with differentiated thyroid carcinoma requiring radioiodine therapy were included in our study. Each patient was given 50-75 mCi (1850-2775 MBq) iodine-131 with 50% dose reduction. Dose rate measurement was performed at the 2nd, 24th, and 48th hour (immediately before and after hemodialysis) after radioiodine administration. The Geiger-Müller probe was held at 1 m distance at the level of the midpoint of the thorax for the dose rate measurement. The effective half-life of iodine-131 for three patients was found to be 44 h. In conclusion, the amount of radioiodine excreted per hemodialysis session was calculated to be 51.25%.

  3. Thyroid Carcinoma

    PubMed

    Ahmed, Najeeb; Niyaz, Kashif; Borakati, Aditya; Marafi, Fahad; Birk, Rubinder; Usmani, Sharjeel

    2018-02-26

    Differentiated thyroid cancer (DTC) has a good prognosis overall; however, lifelong follow-up is required for many cases. Radioiodine planar imaging with iodine-123 (I-123) or radioiodine-131 (I-131) remains the standard in the follow-up after initial surgery and ablation of residual thyroid tissue using I-131 therapy. Radioiodine imaging is also used in risk-stratifying and for staging of thyroid cancer, and in long-term follow-up. Unfortunately, the lack of anatomical detail on planar gamma camera imaging and superimposition of areas presenting with increased radioiodine uptake can make accurate diagnosis and localization of radioiodine-avid metastatic disease challenging, leading to false positive results and potentially to over-treatment of patients. Hybrid SPECT/CT allows precise anatomical localization and superior characterization of foci of increased tracer uptake when compared to planar imaging. This, in turn, allows the differentiation of pathological and physiological uptake, increasing the accuracy of image interpretation and ultimately improving the accuracy of DTC staging and subsequent patient management. In this review, we look at the unique and emerging role that SPECT/CT plays in the management of DTC, illustrated by examples from our own clinical practice. Creative Commons Attribution License

  4. The Program for climate Model diagnosis and Intercomparison: 20-th anniversary Symposium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potter, Gerald L; Bader, David C; Riches, Michael

    Twenty years ago, W. Lawrence (Larry) Gates approached the U.S. Department of Energy (DOE) Office of Energy Research (now the Office of Science) with a plan to coordinate the comparison and documentation of climate model differences. This effort would help improve our understanding of climate change through a systematic approach to model intercomparison. Early attempts at comparing results showed a surprisingly large range in control climate from such parameters as cloud cover, precipitation, and even atmospheric temperature. The DOE agreed to fund the effort at the Lawrence Livermore National Laboratory (LLNL), in part because of the existing computing environment andmore » because of a preexisting atmospheric science group that contained a wide variety of expertise. The project was named the Program for Climate Model Diagnosis and Intercomparison (PCMDI), and it has changed the international landscape of climate modeling over the past 20 years. In spring 2009 the DOE hosted a 1-day symposium to celebrate the twentieth anniversary of PCMDI and to honor its founder, Larry Gates. Through their personal experiences, the morning presenters painted an image of climate science in the 1970s and 1980s, that generated early support from the international community for model intercomparison, thereby bringing PCMDI into existence. Four talks covered Gates's early contributions to climate research at the University of California, Los Angeles (UCLA), the RAND Corporation, and Oregon State University through the founding of PCMDI to coordinate the Atmospheric Model Intercomparison Project (AMIP). The speakers were, in order of presentation, Warren Washington [National Center for Atmospheric Research (NCAR)], Kelly Redmond (Western Regional Climate Center), George Boer (Canadian Centre for Climate Modelling and Analysis), and Lennart Bengtsson [University of Reading, former director of the European Centre for Medium-Range Weather Forecasts (ECMWF)]. The afternoon session emphasized the scientific ideas that are the basis of PCMDI's success, summarizing their evolution and impact. Four speakers followed the various PCMDI-supported climate model intercomparison projects, beginning with early work on cloud representations in models, presented by Robert D. Cess (Distinguished Professor Emeritus, Stony Brook University), and then the latest Cloud Feedback Model Intercomparison Projects (CFMIPs) led by Sandrine Bony (Laboratoire de M'©t'©orologie Dynamique). Benjamin Santer (LLNL) presented a review of the climate change detection and attribution (D & A) work pioneered at PCMDI, and Gerald A. Meehl (NCAR) ended the day with a look toward the future of climate change research.« less

  5. Efficiency analysis of using tailored individual doses of radioiodine and fine tuning using a low-dose antithyroid drug in the treatment of Graves' disease.

    PubMed

    Liu, Chang-Jiang; Dong, Yan-Yu; Wang, Yi-Wei; Wang, Kai-Hua; Zeng, Qun-Yan

    2011-03-01

    To evaluate the effect of using tailored individual doses of radioiodine (¹³¹I) and fine tuning using low-dose antithyroid drug (ATD) in the treatment of Graves' disease, and an attempt to establish a therapeutic strategy that can keep both high rate of euthyroidism and low incidence of hypothyroidism. The dose of radioiodine was calculated using the calculated dose formula, and low-dose ATD was used as a way of fine tuning during follow-up. The intended dose of radioiodine was modified according to the patient's age at radioiodine therapy, thyroid size, and duration of hyperthyroidism before radioiodine therapy in the study group; it was set as 2.96 MBq/g of thyroid in the control group. Twenty patients with Graves' disease were nonrandomly assigned to the control group and 98 patients with Graves' disease to the study group. The outcomes, which included euthyroidism, hypothyroidism, and persistent hyperthyroidism, were determined according to the patients' states at the end of follow-up. In the study group, 74 patients (75.5%) achieved the euthyroid state, six patients (6.1%) became hypothyroid, and 18 patients (18.4%) remained hyperthyroid. The rate of euthyroidism was statistically different between the study group and the control group (75.5 vs. 50%, P=0.03). Of 98 patients with Graves' disease in the study group, 19 patients were additionally treated with ATD during follow-up, and 12 patients achieved euthyroidism. In different age groups or duration of hyperthyroidism groups, the rate of euthyroidism was not statistically different among subgroups of goiter grade 1, grade 2, and grade 3 (P>0.05). Similarly, in different age groups or duration of hyperthyroidism groups, the incidence of hypothyroidism was not statistically different among subgroups of goiter grade 1, grade 2, and grade 3 (P>0.05). However, binary logistic regression analysis showed that thyroid size was associated with overtreatment and undertreatment in our study. Individual doses of radioiodine, adjusted according to the patient's age, thyroid size, and duration of hyperthyroidism, combined with low-dose ATD for some patients, 1 month or more after radioiodine therapy, was an effective method for treating Graves' disease. Our data showed that using tailored individual doses of radioiodine and fine tuning using low-dose ATD may well be a way to keep both high rate of euthyroidism and low incidence of hypothyroidism. The dose of radioiodine should be decreased a little for small goiter and increased a little for large goiter on the basis of our treatment protocol in future study.

  6. The April 1994 and October 1994 radon intercomparisons at EML

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisenne, I.M.; George, A.C.; Perry, P.M.

    1995-10-01

    Quality assurance/quality control (QA/QC) are the backbone of many commercial and research processes and programs. QA/QC research tests the state of a functioning system, be it the production of manufactured goods or the ability to make accurate and precise measurements. The quality of the radon measurements in the US have been tested under controlled conditions in semi-annual radon gas intercomparison exercises sponsored by the Environmental Measurements Laboratory (EML) since 1981. The two Calendar Year 1994 radon gas intercomparison exercises were conducted in the EML exposure chamber. Thirty-two groups including US Federal facilities, USDOE contractors, national and state laboratories, universities andmore » foreign institutions participated in these exercises. The majority of the participant`s results were within {+-}10% of the EML value at radon concentrations of 570 and 945 Bq m{sup {minus}3}.« less

  7. Orbital flourine-18-fluorodeoxyglucose positron emission tomography in patients with Graves' disease for evaluation of active inflammation.

    PubMed

    Uslu-Beşli, Lebriz; Kabasakal, Levent; Sağer, Sait; Cicik, Erdoğan; Asa, Sertaç; Sönmezoğlu, Kerim

    2017-11-01

    Prediction and early diagnosis of orbitopathy is needed in patients with Graves' disease, especially when radioiodine therapy is planned. Positron emission tomography/computerized tomography (PET/CT) using flourine-18-fluorodeoxyglucose (FDG) is an effective imaging modality in detection of inflammation, however, its ability to detect orbital inflammation has not been well studied. The aim of our study is to determine the ability of FDG PET/CT to detect orbital inflammation related with Graves' disease, identify active orbitopathy, predict the radioiodine-triggered orbitopathy, and find out the effects of radioiodine on orbital inflammation. Total 31 Graves' disease patients and 17 controls were included. All Graves' disease patients underwent cranial FDG PET/CT imaging prior therapy. Radioiodine therapy and post-treatment PET/CT study was applied to 21 patients. PET/CT images of all examinees were evaluated, measuring extraocular muscle maximum standard uptake value (SUVmax) and muscle thickness. FDG uptake was increased in the majority of extraocular muscles in Graves' disease patients in comparison to controls and this increase was found to be irrelevant from muscle thickness. Extraocular muscle SUVmax values did not increase in Graves' orbitopathy patients who received radioiodine under corticosteroid prophylaxis. SUVmax level of all orbital rectus muscles were increased after radioiodine therapy in nonsmokers, whereas no increase was detected in smokers. FDG PET/CT may be helpful in detection of extraocular muscle inflammation and it may show ongoing orbitopathy in early stages of inflammation before anatomical changes occur.

  8. Persistent high TRAb values during pregnancy predict increased risk of neonatal hyperthyroidism following radioiodine therapy for refractory hyperthyroidism.

    PubMed

    Hamada, Noboru; Momotani, Naoko; Ishikawa, Naofumi; Yoshimura Noh, Jaeduk; Okamoto, Yasuyuki; Konishi, Toshiaki; Ito, Koichi; Ito, Kunihiko

    2011-01-01

    Serum levels of TSH receptor antibody (TRAb) often increase after radioiodine treatment for Graves' disease, and high-serum levels of maternal TRAb in late pregnancy indicate a risk of neonatal hyperthyroidism. The aim of this retrospective study is to investigate the characteristics of Graves' women who had a history of radioiodine treatment for intractable Graves' disease, and whose neonates suffered from hyperthyroidism. The subjects of this study were 45 patients with Graves' disease who became pregnant during the period from 1988 to 1998 after receiving radioiodine treatment at Ito Hospital. 25 of the 45 subjects had had a relapse of hyperthyroidism after surgical treatment for Graves' disease. 19 pregnancies were excluded because of artificial or spontaneous abortion. In the remaining 44 pregnancies of 35 patients, neonatal hyperthyroidism developed in 5 (11.3%) pregnancies of 4 patients. Serum levels of TRAb at delivery were higher in patients whose neonates suffered from hyperthyroidism (NH mother) than those of patients who delivered normal infants (N mother). Furthermore, serum levels of TRAb in NH mother did not change during pregnancy, although those of 4 patients of N mother, in which serum levels of TRAb before radioiodine treatment were as high as in NH mother, decreased significantly during pregnancy. In conclusion, women who delivered neonates with hyperthyroidism following radioiodine treatment seem to have very severe and intractable Graves' disease. Persistent high TRAb values during pregnancy observed in those patients may be a cause of neonatal hyperthyroidism.

  9. Risk factors for persistent atrial fibrillation following successful hyperthyroidism treatment with radioiodine therapy.

    PubMed

    Zhou, Zhen-Hu; Ma, Long-Le; Wang, Le-Xin

    2011-01-01

    To investigate the predicting factors for persistent atrial fibrillation (AF) following radioiodine therapy for hyperthyroidism. Standard 12-lead ECG and 24-h Holter monitoring were performed in 94 patients (38 males, mean age 46.1±8.2 years) with persistent AF following radioiodine therapy for hyperthyroidism. Left ventricular (LV) function was assessed with two-dimensional echocardiography. Euthyroidism or hypothyroidism was achieved in 81% and 19% of the patients, respectively, after radioiodine therapy. At the end of follow-up (1.6±1.3 years), LV ejection fraction in the 52 patients with LV dysfunction was increased from 39.3±3.3% to 59.0±5.5% (p<0.01). In the 38 patients with pre-treatment paroxysmal AF, no AF was documented during the follow-up. In the 45 patients with pre-treatment persistent AF, AF was found in 27 (60%) during the follow-up. Multivariate logistic regression analysis showed that more than 55 years old in age (RR 2.76, 95% CI: 1.16-8.79, p<0.01), duration of hyperthyroidism (RR 3.08, 95% CI: 1.22-11.41, p<0.01) and duration of pre-treatment atrial fibrillation (RR 2.96, 95% CI: 1.31-7.68, p<0.01) were independent predictors for persistent AF following radioiodine therapy. Older age, duration of hyperthyroidism and pre-treatment duration of AF are risk factors for persistent AF following radioiodine therapy.

  10. Radioiodine Accumulation in a Giant Ovarian Cystadenofibroma Detected Incidentally by 131-I Whole Body Scans

    PubMed Central

    Mebarki, Mohammed; Menemani, Abdelghani; Medjahedi, Abdelkader; Boualou, Fouad; Slama, Abdelhak; Ouguirti, Sarah; Kherbouche, Fatima Zahra; Berber, Nécib

    2012-01-01

    Ovarian cystadenofibroma is a relatively rare tumor; it is usually asymptomatic and is found incidentally. We present the case of a 24-year-old female patient, who had undergone total thyroidectomy for thyroid papillary carcinoma, with an asymptomatic giant cystadenofibroma, incidentally discovered by diagnostic 131I-SPECT/CT WBSs. We summarize the clinical history, imaging data, and histopathological study on a rare case of radioiodine accumulation in cystadenofibroma, and we discuss the mechanism of uptake of radioiodine in this case. PMID:23119215

  11. Radioiodine therapy for thyroid cancer depicted uterine leiomyoma.

    PubMed

    Hirata, Kenji; Shiga, Tohru; Kubota, Kanako C; Okamoto, Shozo; Kamibayashi, Tomohito; Tamaki, Nagara

    2009-03-01

    A 55-year-old woman underwent radioiodine therapy for papillary carcinoma of the thyroid. Post-therapeutic I-131 scan revealed radioiodine uptake in the pelvic region and in the thyroid bed. CT revealed a huge mass connected to the uterus. The tumor was operated on and histologically proven to be a leiomyoma of the uterus. Some physiological conditions or nonthyroidal diseases can cause false positives in patients with postoperative thyroid cancer. We suggest that uterine leiomyoma might be added to the pitfall list, although the mechanism of I-131 uptake remains unclear.

  12. SPECT/CT localization of oral radioiodine activity: a retrospective study and in-vitro assessment.

    PubMed

    Burlison, Jared S; Hartshorne, Michael F; Voda, Alan M; Cocks, Franklin H; Fair, Joanna R

    2013-12-01

    We sought to further localize radioiodine activity in the mouth on post-thyroid cancer therapy imaging using single-photon emission computed tomography/computed tomography (SPECT/CT). We retrospectively reviewed all patients (58) who underwent thyroid cancer therapy with iodine-131 (131I) at our institution from August 2009 to March 2011 whose post-therapy radioiodine imaging included neck SPECT/CT. A small group (six) of diagnostic 131I scans including SPECT/CT was also reviewed. Separately, we performed in-vitro 131I (sodium iodide) binding assays with amalgam and Argenco HP 77 (77% dental gold alloy) as proof of principle for these interactions. Of the 58 post-therapy patients, 45 (78%) had undergone metallic dental restorations, and of them 41 (91%) demonstrated oral 131I activity localizing preferentially to those restorations. It was observed that radioiodine also localized to other dental restorations and to orthodontic hardware. Gum-line activity in edentulous patients suggests radioiodine interaction with denture adhesive. In vitro, dental amalgam and Argenco HP 77 bound 131I in a time-dependent manner over 1-16 days of exposure. Despite subsequent washings with normal saline, significant 131I activity (maximally 12% for amalgam and 68% for Argenco HP 77) was retained by these metals. Subsequent soaking in a saturated solution of potassium iodide partially displaced 131I from amalgam, with near-total displacement of I from Argenco HP 77. SPECT/CT shows that radioiodine in the oral cavity localizes to metallic dental restorations. Furthermore, in-vitro studies demonstrate partially reversible binding of 131I to common dental metals.

  13. Radioiodine therapy of hyperfunctioning thyroid nodules: usefulness of an implemented dose calculation algorithm allowing reduction of radioiodine amount.

    PubMed

    Schiavo, M; Bagnara, M C; Pomposelli, E; Altrinetti, V; Calamia, I; Camerieri, L; Giusti, M; Pesce, G; Reitano, C; Bagnasco, M; Caputo, M

    2013-09-01

    Radioiodine is a common option for treatment of hyperfunctioning thyroid nodules. Due to the expected selective radioiodine uptake by adenoma, relatively high "fixed" activities are often used. Alternatively, the activity is individually calculated upon the prescription of a fixed value of target absorbed dose. We evaluated the use of an algorithm for personalized radioiodine activity calculation, which allows as a rule the administration of lower radioiodine activities. Seventy-five patients with single hyperfunctioning thyroid nodule eligible for 131I treatment were studied. The activities of 131I to be administered were estimated by the method described by Traino et al. and developed for Graves'disease, assuming selective and homogeneous 131I uptake by adenoma. The method takes into account 131I uptake and its effective half-life, target (adenoma) volume and its expected volume reduction during treatment. A comparison with the activities calculated by other dosimetric protocols, and the "fixed" activity method was performed. 131I uptake was measured by external counting, thyroid nodule volume by ultrasonography, thyroid hormones and TSH by ELISA. Remission of hyperthyroidism was observed in all but one patient; volume reduction of adenoma was closely similar to that assumed by our model. Effective half-life was highly variable in different patients, and critically affected dose calculation. The administered activities were clearly lower with respect to "fixed" activities and other protocols' prescription. The proposed algorithm proved to be effective also for single hyperfunctioning thyroid nodule treatment and allowed a significant reduction of administered 131I activities, without loss of clinical efficacy.

  14. Single photon emission computed tomography imaging for temporal dynamics of thyroidal and salivary radionuclide accumulation in 17-allyamino-17-demothoxygeldanamycin-treated thyroid cancer mouse model

    PubMed Central

    Liu, Yu-Yu; Brandt, Michael P; Shen, Daniel H; Kloos, Richard T; Zhang, Xiaoli; Jhiang, Sissy M

    2014-01-01

    Selective iodide uptake and prolonged iodine retention in the thyroid is the basis for targeted radioiodine therapy for thyroid cancer patients; however, salivary gland dysfunction is the most frequent nonthyroidal complications. In this study, we have used noninvasive single photon emission computed tomography functional imaging to quantify the temporal dynamics of thyroidal and salivary radioiodine accumulation in mice. At 60 min post radionuclide injection, radionuclide accumulation in the salivary gland was generally higher than that in thyroid due to much larger volume of the salivary gland. However, radionuclide accumulation per anatomic unit in the salivary gland was lower than that in thyroid and was comparable among mice of different age and gender. Differently, radionuclide accumulation per anatomic unit in thyroid varied greatly among mice. The extent of thyroidal radioiodine accumulation stimulated by a single dose of exogenous bovine TSH (bTSH) in triiodothyronine (T3)-supplemented mice was much less than that in mice received neither bTSH nor T3 (nontreated mice), suggesting that the duration of elevated serum TSH level is important to maximize thyroidal radioiodine accumulation. Furthermore, the extent and duration of radioiodine accumulation stimulated by bTSH was less in the thyroids of the thyroid-targeted RET/PTC1 (thyroglobulin (Tg)-PTC1) mice bearing thyroid tumors compared with the thyroids in wild-type (WT) mice. Finally, the effect of 17-allyamino-17-demothoxygeldanamycin on increasing thyroidal, but not salivary, radioiodine accumulation was validated in both WT mice and Tg-PTC1 preclinical thyroid cancer mouse model. PMID:20943721

  15. Immobilization of radioiodine in synthetic boracite

    DOEpatents

    Babad, H.; Strachan, D.M.

    1982-09-23

    A nuclear waste storage product is disclosed in which radioiodine is incorporated in a synthetic boracite. The boracite may be prepared by reacting a transition metal iodide with an alkali horate under mild hydrothermal conditions, drying the reaction product, and then hot pressing.

  16. Mercuric iodate precipitation from radioiodine-containing off-gas scrubber solution

    DOEpatents

    Partridge, Jerry A.; Bosuego, Gail P.

    1982-01-01

    Mercuric nitrate-nitric acid scrub solutions containing radioiodine may be reduced in volume without excessive loss of volatile iodine. The use of concentrated nitric acid during an evaporation process oxidizes the mercury-iodide complex to a less volatile mercuric iodate precipitate.

  17. Radioiodinated branched carbohydrates

    DOEpatents

    Goodman, Mark M.; Knapp, Jr., Furn F.

    1989-01-01

    A radioiodinated branched carbohydrate for tissue imaging. Iodine-123 is stabilized in the compound by attaching it to a vinyl functional group that is on the carbohydrate. The compound exhibits good uptake and retention and is promising in the development of radiopharmaceuticals for brain, heart and tumor imaging.

  18. Benefits of Sharing Information: Supermodel Ensemble and Applications in South America

    NASA Astrophysics Data System (ADS)

    Dias, P. L.

    2006-05-01

    A model intercomparison program involving a large number of academic and operational institutions has been implemented in South America since 2003, motivated by the SALLJEX Intercomparison Program in 2003 (a research program focused on the identification of the role of the Andes low level jet moisture transport from the Amazon to the Plata basin) and the WMO/THORPEX (www.wmo.int/thorpex) goals to improve predictability through the proper combination of numerical weather forecasts. This program also explores the potential predictability associated with the combination of a large number of possible scenarios in the time scale of a few days to up to 15 days. Five academic institutions and five operational forecasting centers in several countries in South America, 1 academic institution in the USA, and the main global forecasting centers (NCEP, UKMO, ECMWF) agreed to provide numerical products based on operational and experimental models. The metric for model validation is concentrated on the fit of the forecast to surface observations. Meteorological data from airports, synoptic stations operated by national weather services, automatic data platforms maintained by different institutions, the PIRATA buoys etc are all collected through LDM/NCAR or direct transmission. Approximately 40 models outputs are available on a daily basis, twice a day. A simple procedure based on data assimilation principles was quite successful in combining the available forecasts in order to produce temperature, dew point, wind, pressure and precipitation forecasts at station points in S. America. The procedure is based on removing each model bias at the observational point and a weighted average based on the mean square error of the forecasts. The base period for estimating the bias and mean square error is of the order of 15 to 30 days. Products of the intercomparison model program and the optimal statistical combination of the available forecasts are public and available in real time (www.master.iag.usp.br/). Monitoring of the use of the products reveal a growing trend in the last year (reaching about 10.000 accesses per day in recent months). The intercomparison program provides a rich data set for educational products (real time use in Synoptic Meteorology and Numerical Weather Forecasting lectures), operational weather forecasts in national or regional weather centers and for research purposes. During the first phase of the program it was difficult to convince potential participants to share the information in the public homepage. However, as the system evolved, more and more institutions became associated with the program. The general opinion of the participants is that the system provides an unified metric for evaluation, a forum for discussion of the physical origin of the model forecast differences and therefore improvement of the quality of the numerical guidance.

  19. SPECT/CT localization of oral radioiodine activity: a retrospective study and in-vitro assessment

    PubMed Central

    Burlison, Jared S.; Hartshorne, Michael F.; Voda, Alan M.; Cocks, Franklin H.

    2013-01-01

    Purpose We sought to further localize radioiodine activity in the mouth on post-thyroid cancer therapy imaging using single-photon emission computed tomography/computed tomography (SPECT/CT). Materials and methods We retrospectively reviewed all patients (58) who underwent thyroid cancer therapy with iodine-131 (131I) at our institution from August 2009 to March 2011 whose post-therapy radioiodine imaging included neck SPECT/CT. A small group (six) of diagnostic 123I scans including SPECT/CT was also reviewed. Separately, we performed in-vitro 131I (sodium iodide) binding assays with amalgam and Argenco HP 77 (77% dental gold alloy) as proof of principle for these interactions. Results Of the 58 post-therapy patients, 45 (78%) had undergone metallic dental restorations, and of them 41 (91%) demonstrated oral 131I activity localizing preferentially to those restorations. It was observed that radioiodine also localized to other dental restorations and to orthodontic hardware. Gum-line activity in edentulous patients suggests radioiodine interaction with denture adhesive. In vitro, dental amalgam and Argenco HP 77 bound 131I in a time-dependent manner over 1–16 days of exposure. Despite subsequent washings with normal saline, significant 131I activity (maximally 12% for amalgam and 68% for Argenco HP 77) was retained by these metals. Subsequent soaking in a saturated solution of potassium iodide partially displaced 131I from amalgam, with near-total displacement of 131I from Argenco HP 77. Conclusion SPECT/CT shows that radioiodine in the oral cavity localizes to metallic dental restorations. Furthermore, in-vitro studies demonstrate partially reversible binding of 131I to common dental metals. PMID:24128897

  20. Clinical outcomes after estimated versus calculated activity of radioiodine for the treatment of hyperthyroidism: systematic review and meta-analysis.

    PubMed

    de Rooij, A; Vandenbroucke, J P; Smit, J W A; Stokkel, M P M; Dekkers, O M

    2009-11-01

    Despite the long experience with radioiodine for hyperthyroidism, controversy remains regarding the optimal method to determine the activity that is required to achieve long-term euthyroidism. To compare the effect of estimated versus calculated activity of radioiodine in hyperthyroidism. Design Systematic review and meta-analysis. We searched the databases Medline, EMBASE, Web of Science, and Cochrane Library for randomized and nonrandomized studies, comparing the effect of activity estimation methods with dosimetry for hyperthyroidism. The main outcome measure was the frequency of treatment success, defined as persistent euthyroidism after radioiodine treatment at the end of follow-up in the dose estimated and calculated dosimetry group. Furthermore, we assessed the cure rates of hyperthyroidism. Three randomized and five nonrandomized studies, comparing the effect of estimated versus calculated activity of radioiodine on clinical outcomes for the treatment of hyperthyroidism, were included. The weighted mean relative frequency of successful treatment outcome (euthyroidism) was 1.03 (95% confidence interval (CI) 0.91-1.16) for estimated versus calculated activity; the weighted mean relative frequency of cure of hyperthyroidism (eu- or hypothyroidism) was 1.03 (95% CI 0.96-1.10). Subgroup analysis showed a relative frequency of euthyroidism of 1.03 (95% CI 0.84-1.26) for Graves' disease and of 1.05 (95% CI 0.91-1.19) for toxic multinodular goiter. The two main methods used to determine the activity in the treatment of hyperthyroidism with radioiodine, estimated and calculated, resulted in an equally successful treatment outcome. However, the heterogeneity of the included studies is a strong limitation that prevents a definitive conclusion from this meta-analysis.

  1. Materials and processes for the effective capture and immobilization of radioiodine: A review

    DOE PAGES

    Riley, Brian J.; Vienna, John D.; Strachan, Denis M.; ...

    2015-12-02

    In this study, the immobilization of radioiodine produced from reprocessing used nuclear fuel is a growing priority for research and development of nuclear waste forms. This review provides a comprehensive summary of the current issues surrounding processing and containment of 129I, the isotope of greatest concern due to its long half-life of 1.6 × 10 7 y and potential incorporation into the human body. Strategies for disposal of radioiodine, captured by both wet scrubbing and solid sorbents, are discussed, as well as potential iodine waste streams for insertion into an immobilization process. Next, consideration of direct disposal of salts, incorporationmore » into glasses, ceramics, cements, and other phases is discussed. The bulk of the review is devoted to an assessment of various sorbents for iodine and of waste forms described in the literature, particularly inorganic minerals, ceramics, and glasses. This review also contains recommendations for future research needed to address radioiodine immobilization materials and processes.« less

  2. Iodination and stability of somatostatin analogues: comparison of iodination techniques. A practical overview.

    PubMed

    de Blois, Erik; Chan, Ho Sze; Breeman, Wouter A P

    2012-01-01

    For iodination ((125/127)I) of tyrosine-containing peptides, chloramin-T, Pre-Coated Iodo-Gen(®) tubes and Iodo-Beads(®) (Pierce) are commonly used for in vitro radioligand investigations and there have been reliant vendors hereof for decades. However, commercial availability of these radio-iodinated peptides is decreasing. For continuation of our research in this field we investigated and optimized (radio-)iodination of somatostatin analogues. In literature, radioiodination using here described somatostatin analogues and iodination techniques are described separately. Here we present an overview, including High Performance Liquid Chromatography (HPLC) separation and characterisation by mass spectrometry, to obtain mono- and di-iodinated analogues. Reaction kinetics of (125/127)I iodinated somatostatin analogues were investigated as function of reaction time and concentration of reactants, including somatostatin analogues, iodine and oxidizing agent. To our knowledge, for the here described somatostatin analogues, no (127)I iodination and optimization are described. (Radio-)iodinated somatostatin analogues could be preserved with a >90% radiochemical purity for 1 month after reversed phase HPLC-purification.

  3. Data Quality Assessment of In Situ and Altimeter Observations Through Two-Way Intercomparison Methods

    NASA Astrophysics Data System (ADS)

    Guinehut, Stephanie; Valladeau, Guillaume; Legeais, Jean-Francois; Rio, Marie-Helene; Ablain, Michael; Larnicol, Gilles

    2013-09-01

    This proceeding presents an overview of the two-way inter-comparison activities performed at CLS for both space and in situ observation agencies and why this activity is a required step to obtain accurate and homogenous data sets that can then be used together for climate studies or in assimilation/validation tools. We first describe the work performed in the frame of the SALP program to assess the stability of altimeter missions through SSH comparisons with tide gauges (GLOSS/CLIVAR network). Then, we show how the SSH comparison between the Argo array and altimeter time series allows the detection of drifts or jumps in altimeter (SALP program) but also for some Argo floats (Ifremer/Coriolis center). Lastly, we describe how the combine use of altimeter and wind observations helps the detection of drogue loss of surface drifting buoys (GDP network) and allow the computation of a correction term for wind slippage.

  4. Mixed species radioiodine air sampling readout and dose assessment system

    DOEpatents

    Distenfeld, Carl H.; Klemish, Jr., Joseph R.

    1978-01-01

    This invention provides a simple, reliable, inexpensive and portable means and method for determining the thyroid dose rate of mixed airborne species of solid and gaseous radioiodine without requiring highly skilled personnel, such as health physicists or electronics technicians. To this end, this invention provides a means and method for sampling a gas from a source of a mixed species of solid and gaseous radioiodine for collection of the mixed species and readout and assessment of the emissions therefrom by cylindrically, concentrically and annularly molding the respective species around a cylindrical passage for receiving a conventional probe-type Geiger-Mueller radiation detector.

  5. [Structural and functional status of the hypophyseal-thyroid system in prenatally irradiated children].

    PubMed

    Makiienko, T S; Pavliuk, V P; Pavliuk, I V; Mosiienko, A P

    2001-01-01

    In order to evaluate the morphologic-and-functional state of the hypophysis-thyroid system long after the Chernobyl accident we examined 1491 children from the northern territories of the Zhitomir region. Of these, 261 had not been in utero exposed to radioiodine, 1230 pediatric subjects proved to be postconception-exposed. In utero radioiodine has not been found to affect the thyroid size in any noticeable way. The degree of structural-and-functional indices for the thyreostat system in prenatally irradiated children depends on the stage of the thyroid development just when there happened to be an exposure to radioiodine.

  6. [Role of iodine-131 in the management of differentiated thyroid cancers (vesicular origin)].

    PubMed

    Boughattas, Sami; Hassine, Habib; Chatti, Kaouther; Letaief, Bechir; Jomaa, Rached; Essabbah, Habib

    2002-08-01

    Radioodine-131 has an important place in the management of well-differentiated thyroid cancer. Patient preparation for radioiodine-131 administration must be rigorous and is based on the stimulation of endogenous TSH production, which requires a hypothyroid state after withdrawal of suppressive T4-therapy. The introduction of recombinant human TSH would simplify the protocol of preparation and improve the quality of life of patients. The diagnosis place of radioiodine-131 knew significant changes following the introduction of the serum thyroglobulin measurement. This tumour marker has a central role in the strategy of follow-up and tends to be the principal element of indication for a diagnosis exploration with radioidine-131. The systematic ablation of thyroid remnants remains controversial particularly in patients with good prognosis factors; the efficacy of low activities is also still debatable. The optimal follow-up strategy and the indication of remnant ablation must take in account the prognosis factors of survival and recurrence. Radioiodine-131 therapy permits frequently the cure of distant metastases, particularly in infraradiological pulmonary forms. This fact outlines the importance of an early detection of tumour recurrence based on the conjunction of radioiodine-131 and thyroglobulin. Side effects of radioiodine-131 therapy are generally limited if the precautionary measures are well applied; leukaemia constitutes the main risk but this complication is very uncommon and occurs after a high cumulative activity.

  7. Defects in iodide metabolism in thyroid cancer and implications for the follow-up and treatment of patients.

    PubMed

    Schlumberger, Martin; Lacroix, Ludovic; Russo, Diego; Filetti, Sebastiano; Bidart, Jean-Michel

    2007-03-01

    The two major steps of iodine metabolism--uptake and organification--are altered in thyroid cancer tissues. Organification defects result in a rapid discharge of radioiodine from thyroid cells, a short effective half-life of iodine, and a low rate of thyroid hormone synthesis. These defects are mainly due to decreased expression of functional genes encoding the sodium-iodide symporter and thyroid peroxidase and could result in a low radiation dose to thyroid cancer cells. TSH stimulation that is achieved with injections of recombinant human TSH, or long-term withdrawal of thyroid hormone treatment increases iodine-131 uptake in two-thirds of patients with metastatic disease and increases thyroglobulin production in all patients with metastases, even in the absence of detectable uptake. Serum thyroglobulin determination obtained following TSH stimulation and neck ultrasonography is the most sensitive combination for the detection of small tumor foci. Radioiodine treatment is effective when a high radiation dose can be delivered (in patients with high uptake and retention of radioiodine) and when tumor foci are sensitive to the effects of radiation therapy (younger patients, with a well-differentiated tumor and/or with small metastases). The other patients rarely respond to radioiodine treatment, and when progression occurs, other treatment modalities should be considered. Novel strategies are currently being explored to restore iodine uptake in cancer cells that are unable to concentrate radioiodine.

  8. A review of countermeasures to reduce radioiodine in milk of dairy animals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard, B.J.; Voigt, G.; Segal, M.G.

    1996-11-01

    The most effective countermeasure for radioiodine contamination of milk is to provide dairy animals with uncontaminated feed, with the added advantage that it will be effective for other radionuclides in the fallout. Another effective response is to process the milk into storable dairy products for an appropriate length of time to allow for physical decay. The use of additives given to ruminants to reduce radioiodine in milk is an alternative countermeasure which could be effective. Stable iodine administration is a practically feasible option which has the potential to reduce radioiodine levels in milk by at most a factor of three.more » Stable iodine supplementation should be at sufficiently high rates to be effective (and at least 1 g d{sup {minus}1} for dairy cows), particularly for ruminants already receiving high amounts of iodine in the diet. Currently available data are inadequate to recommend a suitable stable iodine administration rate for different species of ruminants. Other compounds, such as perchlorate and thiocyanate, also reduce the transfer to radioiodine to milk (and thyroid). Some of these compounds seem to be potentially equally as effective as stable iodine. However, currently there is inadequate information on their effectiveness and possible toxicity to both ruminants and humans for these compounds to be considered as suitable countermeasure additives. 85 refs., 2 figs., 3 tabs.« less

  9. Guidelines for the use of radioiodine in the management of hyperthyroidism: a summary. Prepared by the Radioiodine Audit Subcommittee of the Royal College of Physicians Committee on Diabetes and Endocrinology, and the Research Unit of the Royal College of Physicians.

    PubMed

    Lazarus, J H

    1995-01-01

    Radioiodine (131I) therapy is indicated in patients with nearly all causes of hyperthyroidism. It may safely be given to patients of all age groups but is less often given to children under 10 years old. It is completely contraindicated in pregnancy and while breast feeding, but there is no increased risk of thyroid cancer, leukaemia or solid tumours. Administration of radioiodine must conform to regulations and definitions laid down by ARSAC And POPUMET. Medical staff authorising therapy must hold an ARSAC licence. The recommended strategy is to give an activity sufficient to render the patient rapidly euthyroid and maintain that state or achieve no more than a low rate of hypothyroidism in subsequent years. A range of activity (300-800 MBq) is suggested depending on the clinical state. Antithyroid drugs may be given before or after (or both) radioiodine if necessary. Full written information should be given to the patient and written consent obtained. A structured follow-up should be used ensuring regular measurement of TSH or FT4. Close cooperation with the patient's general practitioner is recommended throughout the assessment, treatment and follow-up. Shared care with a computer based follow-up system is recommended.

  10. 131I therapy of thyroid cancer patients.

    PubMed

    Reiners, C; Farahati, J

    1999-12-01

    Thyroid cancer is a rare malignancy with wide interethnic and geographic variations. In Germany thyroid carcinoma is the 13th most frequent malignancy (2.7 new cases yearly per 100,000 inhabitants). The overall temporal incidence is increasing slightly in recent years. The most common types of cancer are papillary (60-80%) and follicular cancers (10-20%). The relevant prognostic indicators are tumor stage and distant metastases. The mean survival rates in papillary thyroid cancer usually exceed 90%, whereas in follicular thyroid cancer they amount to approximately 80%. The standard treatment procedure in differentiated papillary and follicular thyroid cancer consists of total thyroidectomy followed by adjuvant ablative therapy with radioiodine. Only in papillary thyroid cancer stage pT1N0M0 lobectomy alone is considered to be appropriate. In patients with locally invasive differentiated thyroid cancers stage pT4 adjuvant percutaneous radiation therapy is a treatment option. Radioiodine therapy has to be performed under the stimulative influence of TSH. Usually TSH suppressive medication with Levothyroxine has to be withdrawn approximately 4 weeks prior to radioiodine therapy. In the future, exogenous stimulation by recombinant TSH may be used instead of thyroid hormone withdrawal. It has been proven by different studies that ablative radioiodine therapy reduces the frequency of recurrences and tumor spread in patients with thyroid cancer significantly. In patients with distant metastases, up to 50% of complete responses may be achieved with radioiodine treatment.

  11. Radioiodinated glucose analogues for use as imaging agents

    DOEpatents

    Goodman, Mark M.; Knapp, Jr., Furn F.

    1988-01-01

    A radioiodinated branched carbohydrate for tissue imaging. Iodine-123 is stabilized in the compound by attaching it to a vinyl functional group that is on the carbohydrate. The compound exhibits good uptake and retention and is promising in the development of radiopharmaceuticals for brain, heart and tumor imaging.

  12. [Implementation of quality standard UNE-EN ISO/IEC 17043 in the External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology].

    PubMed

    Poveda Gabaldón, Marta; Ovies, María Rosario; Orta Mira, Nieves; Serrano, M del Remedio Guna; Avila, Javier; Giménez, Alicia; Cardona, Concepción Gimeno

    2011-12-01

    The quality standard "UNE-EN-ISO 17043: 2010. Conformity assessment. General requirements for proficiency testing" applies to centers that organize intercomparisons in all areas. In the case of clinical microbiology laboratories, these intercomparisons must meet the management and technical standards required to achieve maximum quality in the performance of microbiological analysis and the preparation of test items (sample, product, data or other information used in the proficiency test) to enable them to be accredited. Once accredited, these laboratories can operate as a tool for quality control laboratories and competency assessment. In Spain, accreditation is granted by the Spanish Accreditation Body [Entidad Nacional de Acreditación (ENAC)]. The objective of this review is to explain how to apply the requirements of the standard to laboratories providing intercomparisons in the field of clinical microbiology (the organization responsible for all the tasks related to the development and operation of a proficiency testing program). This requires defining the scope and specifying the technical requirements (personnel management, control of equipment, facilities and environment, the design of the proficiency testing and data analysis for performance evaluation, communication with participants and confidentiality) and management requirements (document control, purchasing control, monitoring of complaints / claims, non-compliance, internal audits and management reviews). Copyright © 2011 Elsevier España S.L. All rights reserved.

  13. Low-cost solar array project: Four absolute cavity radiometer (pyrheliometer) intercomparisons at New River, Arizona: Radiometer standards

    NASA Technical Reports Server (NTRS)

    Estey, R. S.; Seaman, C. H.

    1981-01-01

    Four detailed intercomparisons were made for a number of models of cavity-type self-calibrating radiometers (pyrheliometers). Each intercomparison consisted of simultaneous readings of pyrheliometers at 30-second intervals in runs of 10 minutes, with at least 15 runs per intercomparison. Twenty-seven instruments were in at least one intercomparison, and five were in all four. Summarized results and all raw data are provided from the intercomparisons.

  14. NOAA National Status and Trends Program Twelfth Round Intercomparison Exercise Results for Trace Metals in Marine Sediments and Biological Tissues. National Status and Trends Program for marine environmental quality: Technical memo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willie, S.

    1998-11-01

    The report summarizes the results of the Twelfth Round Intercomparison for Trace Metals in Marine Sediments and Biological Tissues under the directive of the NOAA National Status and Trends Program. A total of forty-four participants were included in the exercise, including NOAA, USEPA, state, Austrailian, Canadian, Mexican and Argentinean laboratories. Two samples were sent by NRC to each participant, a marine sediment collected on the east coast of Canada and a freeze-dried mussel tissue. Laboratories were also asked to analyze two certified reference materials (CRMs) MESS-2 and CRM 2976. The elements to be determined were Al, Cr, Fe, Ni, Cu,more » Zn, As, Se, Ag, Cd, Sn, Hg, and Pb for both matrices, plus Be, Si, Mn, Sb, and Tl for the sediments. An accepted mean and confidence interval was calculated for each analyte in the two unknown samples, laboratory biases were identified and an overall rating of superior, good, fair or others were assigned to each laboratory.« less

  15. Intercomparisons of radiosondes and an airborne refractometer for measuring radio ducts

    NASA Astrophysics Data System (ADS)

    Morrissey, J. F.; Izumi, Y.; Cote, O. R.

    1986-07-01

    The capabilities of two types of radiosondes and an aircraft refractometer to measure radio ducting conditions were compared in a series of flights in September 1985 at Chatham, Mass., on Cape Cod. The tests were part of a program studying radio propagation on Air Force communication links. The intercomparisons were made between data from a refractometer mounted on a small single engine aircraft (Cessna 172) and data from an operational National Weather Service synoptic sounding system. The synoptic sonde and the portable sonde were often on the same balloon train. The comparisons show that the aircraft refractometer data indicate the highest number of ducts and the synoptic data the least number of ducts.

  16. [The radioiodine test for the evaluation of iodine deficiency in the district of Karl-Marx-Stadt and in East Germany].

    PubMed

    Bauch, K; Weiss, O; Möckel, G; Gerlach, J; Seitz, W; Ulrich, F E; Dempe, A

    1981-10-01

    The values of the per cent 24 h radioiodine uptake in the GDR are above 60--70% and speak for a low alimentary intake of iodine or renal excretion of iodine below 40 micrograms J/d. Like the struma prevalences they show a tendency increasing from north to south and characterize the whole European situation of iodine deficiency including its decrease from west to east. The mean values of radioiodine uptake of 71.7 +/- 13.2% (n = 110) in euthyroids of the district of Karl-Marx-Stadt correspond to the iodine deficiency as it occurs approximately in the districts of Erfurt, Dresden, Munich or Freiburg/B. The alimentary iodine intake of 38.4 +/- 17.2 micrograms J/d and the renal iodine excretion of 29.9 +/- 16.1 micrograms J/d, calculated from the 24 h radioiodine accumulation values of 40 euthyroid persons by means of a mathematical model developed by Oddie and co-workers were low. The latter only slightly differed (P less than 0.05) from its chemically estimated excretion of iodine in the urine: 23.1 +/- 16.9 micrograms J/g creatinine (n = 73). Between the calculated and chemically estimated excretion of iodine there was a relatively strict correlation of r = 0.68 (n = 26; P less than 0.001). The introduction of an iodine prophylaxis is regarded as an urgent necessity. Later on a new estimation of the regional "normal values" is necessary for the per cent radioiodine uptake.

  17. Limits of fetal thyroid risk from radioiodine exposure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lloyd, R.D.; Tripp, D.A.; Kerber, R.A.

    1996-04-01

    An incident in which a young women became pregnant soon after being treated with 444 MBq {sup 131}I for Graves disease prompted us to search local records for the occurrence of thyroid abnormalities among people exposed in utero to fallout radioiodine. The data base from the Utah Fallout Study indicated that there had been 480 cohort subjects for whom dose to thyroid from fallout radioiodine had been calculated and who could have received any thyroid dose before birth (2473 subjects had been re-examined in 1985-86 of the 4818 examined in 1965-70). Of these 480 subjects in this category, 403 ofmore » them could be located in the 1980`s and were examined for abnormalities. Although nodules, thyroiditis, hypothyroidism and goiter were seen among the 375 persons with in utero thyroid doses from fallout radioiodine below 0.42 Gy, no thyroid abnormalities of any kind occurred in the 4 persons with in utero thyroid doses of 0.5 to 2.6 Gy. In addition, no neoplasia was found in any of the 403 subjects examined about 3 decades after in utero fallout exposure. These limited data do not indicate that the fetal thyroid is more sensitive than the postnatal thyroid by more than about a factor of about 4 when thyroid dose is considered and by not much more than unity when the comparison is based on dose equivalent (x-ray vs. radioiodine). 21 refs., 1 tab.« less

  18. Apigenin in Combination with Akt Inhibition Significantly Enhances Thyrotropin-Stimulated Radioiodide Accumulation in Thyroid Cells

    PubMed Central

    Lakshmanan, Aparna; Doseff, Andrea I.; Ringel, Matthew D.; Saji, Motoyasu; Rousset, Bernard; Zhang, Xiaoli

    2014-01-01

    Background: Selectively increased radioiodine accumulation in thyroid cells by thyrotropin (TSH) allows targeted treatment of thyroid cancer. However, the extent of TSH-stimulated radioiodine accumulation in some thyroid tumors is not sufficient to confer therapeutic efficacy. Hence, it is of clinical importance to identify novel strategies to selectively further enhance TSH-stimulated thyroidal radioiodine accumulation. Methods: PCCl3 rat thyroid cells, PCCl3 cells overexpressing BRAFV600E, or primary cultured tumor cells from a thyroid cancer mouse model, under TSH stimulation were treated with various reagents for 24 hours. Cells were then subjected to radioactive iodide uptake, kinetics, efflux assays, and protein extraction followed by Western blotting against selected antibodies. Results: We previously reported that Akt inhibition increased radioiodine accumulation in thyroid cells under chronic TSH stimulation. Here, we identified Apigenin, a plant-derived flavonoid, as a reagent to further enhance the iodide influx rate increased by Akt inhibition in thyroid cells under acute TSH stimulation. Akt inhibition is permissive for Apigenin's action, as Apigenin alone had little effect. This action of Apigenin requires p38 MAPK activity but not PKC-δ. The increase in radioiodide accumulation by Apigenin with Akt inhibition was also observed in thyroid cells expressing BRAFV600E and in primary cultured thyroid tumor cells from TRβPV/PV mice. Conclusion: Taken together, Apigenin may serve as a dietary supplement in combination with Akt inhibitors to enhance therapeutic efficacy of radioiodine for thyroid cancer. PMID:24400871

  19. Effect of specific activity on organ uptake of iodine-123-meta-iodobenzylguanidine in humans.

    PubMed

    Farahati, J; Lassmann, M; Scheubeck, M; Bier, D; Hanscheid, H; Schelper, L; Grelle, I; Biko, J; Werner, E; Graefe, K; Reiners, C

    1997-04-01

    Radioiodinated meta-iodobenzylguanidine (MIBG), an analogue of norepinephrine, has been used in management of neuroendocrine tumors. Recent studies reveal that distribution of radioiodinated MIBG in animals depends on the specific activity of this radiopharmaceutical. In order to clarify the effect of specific activity on organ uptake of radioiodinated MIBG. the kinetics of no-carrier-added (n.c.a.) [I-123]MIBG (greater than or equal to 7.4 TBq/mu mol) were compared with those of commercial (com.) [I-123]MIBG (similar to 74 MBq/mu mol) in 3 healthy volunteers by serial imaging and blood sampling. The organ uptake of radioiodinated MIBG did not remarkably differ between the two specific activities. Due to rapid degradation a more pronounced accumulation of radioactivity was present in plasma alter n.c.a. than after com. [I-123]MIBG resulting in a higher background and thyroid activity. In addition due to a prolonged residence time of the radioactivity, the radiation exposure to organs was in general slightly higher with n.c.a. [I-123]MIBG as compared to com. [I-123]MIBG. This finding highlights the higher in vivo deiodination of n.c.a. [I-123]MIBG than of com. [I-123]MIBG in humans. In the treatment of children suffering from neuroblastoma, therefore, degradation of n.c.a. [I-123]MIBG may decrease the concentration of radioiodinated MIBG available for binding at tumor sites and result in higher radiation exposure of non-tumor tissue.

  20. Inhibition of miR-146b expression increases radioiodine-sensitivity in poorly differential thyroid carcinoma via positively regulating NIS expression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Luchuan; Lv, Bin; Chen, Bo

    2015-07-10

    Dedifferentiated thyroid carcinoma (DTC) with the loss of radioiodine uptake (RAIU) is often observed in clinical practice under radioiodine therapy, indicating the challenge for poor prognosis. MicroRNA (miRNA) has emerged as a promising therapeutic target in many diseases; yet, the role of miRNAs in RAIU has not been generally investigated. Based on recent studies about miRNA expression in papillary or follicular thyroid carcinomas, the expression profiles of several thyroid relative miRNAs were investigated in one DTC cell line, derived from normal DTC cells by radioiodine treatment. The top candidate miR-146b, with the most significant overexpression profiles in dedifferentiated cells, wasmore » picked up. Further research found that miR-146b could be negatively regulated by histone deacetylase 3 (HDAC3) in normal cells, indicating the correlation between miR-146b and Na{sup +}/I{sup −} symporter (NIS)-mediated RAIU. Fortunately, it was confirmed that miR-146b could regulate NIS expression/activity; what is more important, miR-146b interference would contribute to the recovery of radioiodine-sensitivity in dedifferentiated cells via positively regulating NIS. In the present study, it was concluded that NIS-mediated RAIU could be modulated by miR-146b; accordingly, miR-146b might serve as one of targets to enhance efficacy of radioactive therapy against poorly differential thyroid carcinoma (PDTC). - Highlights: • Significant upregulated miR-146b was picked up from thyroid relative miRNAs in DTC. • MiR-146b was negatively regulated by HDAC3 in normal thyroid carcinoma cells. • NIS activity and expression could be regulated by miR-146b in thyroid carcinoma. • MiR-146b inhibition could recover the decreased radioiodine-sensitivity of DTC cells.« less

  1. Hybrid Vision-Fusion system for whole-body scintigraphy.

    PubMed

    Barjaktarović, Marko; Janković, Milica M; Jeremić, Marija; Matović, Milovan

    2018-05-01

    Radioiodine therapy in the treatment of differentiated thyroid carcinoma (DTC) is used in clinical practice for the ablation of thyroid residues and/or destruction of tumour tissue. Whole-body scintigraphy for visualization of the spatial 131I distribution performed by a gamma camera (GC) is a standard procedure in DTC patients after application of radioiodine therapy. A common problem is the precise topographic localization of regions where radioiodine is accumulated even in SPECT imaging. SPECT/CT can provide precise topographic localization of regions where radioiodine is accumulated, but it is often unavailable, especially in developing countries because of the high price of the equipment. In this paper, we present a Vision-Fusion system as an affordable solution for 1) acquiring an optical whole-body image during routine whole-body scintigraphy and 2) fusing gamma and optical images (also available for the auto-contour mode of GC). The estimated prediction error for image registration is 1.84 mm. The validity of fusing was tested by performing simultaneous optical and scintigraphy image acquisition of the bar phantom. The fusion result shows that the fusing process has a slight influence and is lower than the spatial resolution of GC (mean value ± standard deviation: 1.24 ± 0.22 mm). The Vision-Fusion system was used for radioiodine post-therapeutic treatment, and 17 patients were followed (11 women and 6 men, with an average age of 48.18 ± 13.27 years). Visual inspection showed no misregistration. Based on our first clinical experience, we noticed that the Vision-Fusion system could be very useful for improving the diagnostic possibility of whole-body scintigraphy after radioiodine therapy. Additionally, the proposed Vision-Fusion software can be used as an upgrade for any GC to improve localizations of thyroid/tumour tissue. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. The Continuous Intercomparison of Radiation Codes (CIRC): Phase I Cases

    NASA Technical Reports Server (NTRS)

    Oreopoulos, Lazaros; Mlawer, Eli; Delamere, Jennifer; Shippert, Timothy; Turner, David D.; Miller, Mark A.; Minnis, Patrick; Clough, Shepard; Barker, Howard; Ellingson, Robert

    2007-01-01

    CIRC aspires to be the successor to ICRCCM (Intercomparison of Radiation Codes in Climate Models). It is envisioned as an evolving and regularly updated reference source for GCM-type radiative transfer (RT) code evaluation with the principle goal to contribute in the improvement of RT parameterizations. CIRC is jointly endorsed by DOE's Atmospheric Radiation Measurement (ARM) program and the GEWEX Radiation Panel (GRP). CIRC's goal is to provide test cases for which GCM RT algorithms should be performing at their best, i.e, well characterized clear-sky and homogeneous, overcast cloudy cases. What distinguishes CIRC from previous intercomparisons is that its pool of cases is based on observed datasets. The bulk of atmospheric and surface input as well as radiative fluxes come from ARM observations as documented in the Broadband Heating Rate Profile (BBHRP) product. BBHRP also provides reference calculations from AER's RRTM RT algorithms that can be used to select the most optimal set of cases and to provide a first-order estimate of our ability to achieve radiative flux closure given the limitations in our knowledge of the atmospheric state.

  3. MicroSPECT imaging of triple negative breast cancer cell tumor xenografted in athymic mice with radioiodinated anti-ICAM-1 monoclonal antibody.

    PubMed

    You, Linyi; Wang, Xiangyu; Guo, Zhide; Zhang, Deliang; Zhang, Pu; Li, Jindian; Su, Xinhui; Pan, Weimin; Zhang, Xianzhong

    2018-04-04

    Intercellular adhesion molecule-1(ICAM-1) is a potential molecular target and biomarker for triple negative breast cancer (TNBC) therapy and diagnosis. In this study, aICAM-1 was radioiodinated with 125 I/ 131 I in high radiochemical yield and the probes for TNBC tumor targeting and radioimmunotherapy were evaluated in tumor-bearing mice. High and specific accumulation of 125 I-aICAM1 in TNBC MDA-MB-231 tumor was observed in SPECT imaging and the tumor grew was inhibited obviously by 131 I-aICAM1. Thus, the radioiodinated aICAM1 could serve as potential agents for TNBC theranostics. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Indoor and Outdoor Spectroradiometer Intercomparison for Spectral Irradiance Measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habte, A.; Andreas, A.; Ottoson, L.

    2014-05-01

    This report details the global spectral irradiance intercomparison using spectroradiometers that was organized by the National Renewable Energy Laboratory's Solar Radiation Research Laboratory. The intercomparison was performed both indoors and outdoors on September 17, 2013. Five laboratories participated in the intercomparison using 10 spectroradiometers, and a coordinated measurement setup and a common platform were employed to compare spectral irradiances under both indoor and outdoor conditions. The intercomparison aimed to understand the performance of the different spectroradiometers and to share knowledge in making spectral irradiance measurements. This intercomparison was the first of its kind in the United States.

  5. Radioiodine Labeled Anti-MIF McAb: A Potential Agent for Inflammation Imaging

    PubMed Central

    Zhang, Chao; Hou, Gui-hua; Han, Jian-kui; Song, Jing; Liang, Ting

    2007-01-01

    Macrophage migration inhibitory factor (MIF) is a proinflammatory cytokine that may play a role in the pathogenesis of inflammation. Radiolabeled anti-MIF McAb can be used to detect in vivo inflammatory changes. The objective of this study was to investigate in vivo biology of radioiodinated anti-MIF McAb using the inflammation model mice. Anti-MIF McAb was radioiodinated with NaI125 by Iodogen method. Animal models were induced in the mice by intramuscular injection of S. aureus, E. coli, and turpentine oil. The biodistribution studies with radioiodinated anti-MIF McAb were performed on inflammation mice. The relationship between inflammatory lesions and anti-MIF McAb binding was investigated using the percent of injected dose per gram tissue (% ID/g) of tissue samples and whole-body autoradiography. The radioactivity of I125-anti-MIF McAb in the inflammatory tissue increased gradually for three inflammation models. The highest uptake was found in S. aureus group and the lowest was in E. coli group. The uptake in turpentine oil group was average. Whole-body autoradiography showed that all inflammation foci could be visualized clearly from 24 hours after injection, but 48 hours images were much clearer in accordance with the high T/NT ratio. These results demonstrate the ability of radioiodinated anti-MIF McAb to measure in vivo inflammatory events represented by high expression of MIF and suggests that radiolabeled anti-MIF McAb warrants further investigation as a potential inflammation-seeking agent for imaging to detect inflammatory disorders. PMID:18317509

  6. Lithium carbonate pre-treatment in 131-I therapy of hyperthyroidism.

    PubMed

    Płazińska, Maria Teresa; Królicki, Leszek; Bąk, Marianna

    2011-01-01

    The aim of the present work was to investigate the influence of lithium carbonate on the kinetics of radioiodine in the thyroid gland, and the long-lasting effect of radioiodine therapy pre-treated with lithium carbonate in patients with different types of hyperthyreosis and low baseline 24-h thyroidal radioactive iodine uptake (RAIU). The examinations were performed in two groups of patients: in a control group with RAIU 〉 30% and in patients with RAIU 〈 30%. All groups were comparable with regard to age, sex, duration and type of disease (Graves' disease, autonomous node, multinodular goitre). The control group was treated (without lithium) according to described protocol. The second group was pre-treated with lithium carbonate in a dose of 1.0 g/day for 6 days before radioiodine and 3 days thereafter. A significant increase in iodide uptake in the thyroid gland was observed during intake of lithium carbonate in 106 out of 128 patients. A decrease of T(3), FT(3), T(4), and FT(4) levels and no significant changes in concentration of TSH were observed as an effect of lithium carbonate treatment. Three years of follow-up show that the results of radioiodine therapy with short lasting lithium carbonate intake are better in the first year and are similar in the second and third years in comparison to the control group. Lithium pre-treatment in hyperthyroid patients with low baseline uptake of radioiodine can increase iodine retention in the thyroid gland independently of the primary disease and permits the use of lower doses of radiation in the therapy.

  7. Earth orientation from lunar laser ranging and an error analysis of polar motion services

    NASA Technical Reports Server (NTRS)

    Dickey, J. O.; Newhall, X. X.; Williams, J. G.

    1985-01-01

    Lunar laser ranging (LLR) data are obtained on the basis of the timing of laser pulses travelling from observatories on earth to retroreflectors placed on the moon's surface during the Apollo program. The modeling and analysis of the LLR data can provide valuable insights into earth's dynamics. The feasibility to model accurately the lunar orbit over the full 13-year observation span makes it possible to conduct relatively long-term studies of variations in the earth's rotation. A description is provided of general analysis techniques, and the calculation of universal time (UT1) from LLR is discussed. Attention is also given to a summary of intercomparisons with different techniques, polar motion results and intercomparisons, and a polar motion error analysis.

  8. Results of the August 1977 Soviet and American meterological rocketsonde intercomparison held at Wallops Island, Virginia

    NASA Technical Reports Server (NTRS)

    Schmidlin, F. J.; Duke, J. R.; Ivanovsky, A. I.; Chernyshenko, Y. M.

    1980-01-01

    A coordinated program of rocketsonde investigations along about 60 deg E and 70 deg W between the United States and U.S.S.R. is discussed. The rocketsonde instruments used by the U.S. and U.S.S.R. were compared and the results are presented. The U.S. Super Loki Datasonde and the U.S.S.R. M100B rocketsonde are discussed. Results indicate that the U.S/U.S.S.R. rocketsonde measurement agreement improved since the 1973 intercomparisons. It was learned that the mean of the differences of the temperatures compare to within 6 C at about 60 km and to within 2 C near 50 km. Wind measurements were also found to agree.

  9. Tinea corporis overlying the thyroid gland after radioiodine (131I) treatment of Graves' disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreno, A.J.; Hartshorne, M.F.; Yedinak, M.A.

    1986-04-01

    A case of tinea corporis involving the skin overlying the thyroid gland is described in a 36-year-old man who had received radioiodine treatment for Graves' disease. The dermatophytosis mimicked a delayed roentgen erythema. Radiation to the dermis may have locally altered the cell-mediated immunity and predisposed this patient to the dermatophytosis.

  10. An intercomparison of aircraft instrumentation for tropospheric measurements of sulfur dioxide

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Davis, Douglas D.; Beltz, Nobert; Bandy, Alan R.; Ferek, Ronald J.; Thornton, Donald C.

    1993-01-01

    As part of the NASA Tropospheric Chemistry Program, a series of field intercomparisons have been conducted to evaluate the state-of-the art for measuring key tropospheric species. One of the objectives of the third intercomparison campaign in this series, Chemical Instrumentation Test and Evaluation 3 (CITE 3), was to evaluate instrumentation for making reliable tropospheric aircraft measurements of sulfur dioxide, dimethyl sulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide. This paper reports the results of the intercomparisons of five sulfur dioxide measurement methods ranging from filter techniques, in which samples collected in flight are returned to the laboratory for analyses (chemiluminescent or ion chromatographic), to near real-time, in-flight measurements via gas chromatographic, mass spectrometric, and chemiluminescent techniques. All techniques showed some tendency to track sizeable changes in ambient SO2 such as those associated with altitude changes. For SO2 mixing ratios in the range of 200 pptv to a few ppbv, agreement among the techniques varies from about 30% to several orders of magnitude, depending upon the pair of measurements intercompared. For SO2 mixing ratios less than 200 pptv, measurements from the techniques are uncorrelated. In general, observed differences in the measurement of standards do not account for the flight results. The CITE 3 results do not unambiguously identify one or more of the measurement techniques as providing valid or invalid SO2 measurements, but identify the range of 'potential' uncertainty in SO2 measurements reported by currently available instrumentation and as measured under realistic aircraft environments.

  11. Climate observing system studies: An element of the NASA Climate Research Program: Workshop report

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Plans for NASA's efforts in climatology were discussed. Targets for a comprehensive observing system for the early 1990's were considered. A program to provide useful data in the near and mid-term, and a program to provide for a feasibility assessment of instruments and methods for the development of a long-term system were discussed. Climate parameters that cannot be measured from space were identified. Long-term calibration, intercomparison, standards, and ground truth were discussed.

  12. Atmospheric Radiation Measurement Program Facilities Newsletter - September 1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holdridge, D. J., ed

    The Atmospheric Radiation Measurement Program September 1999 Facilities Newsletter discusses the several Intensive Observation Periods (IOPs) that the ARM SGP CART site will host in the near future. Two projects of note are the International Pyrgeometer Intercomparison and the Fall Single Column Model (SCM)/Nocturnal Boundary Layer (NBL) IOP. Both projects will bring many US and international scientists to the SGP CART site to participate in atmospheric research.

  13. Agricultural model intercomparison and improvement project: Overview of model intercomparisons

    USDA-ARS?s Scientific Manuscript database

    Improvement of crop simulation models to better estimate growth and yield is one of the objectives of the Agricultural Model Intercomparison and Improvement Project (AgMIP). The overall goal of AgMIP is to provide an assessment of crop model through rigorous intercomparisons and evaluate future clim...

  14. Grave's Eye disease developing following radioiodine treatment for toxic nodular goitre.

    PubMed

    Tahrani, A A; Rangan, S; Moulik, P

    2007-07-01

    The development of Grave's ophthalmopathy (GO) following radioiodine (RI) treatment for Grave's thyrotoxicosis, though controversial, is well described. The development of ophthalmopathy following RI treatment for toxic nodular goitre is much less recognised. We report a 49 year-old female patient who developed thyrotoxicosis and GO after receiving RI treatment for toxic nodular goitre and we also review the relevant literature.

  15. A rare case of laryngotracheal chondrosarcoma in a patient with past history of radioiodine therapy for thyroid cancer.

    PubMed

    Mohajeri, Gholamreza; Hekmatnia, Ali; Ahrar, Hossein; Hekmatnia, Farzane; Nia, Reza Basirat; Afsharmoghadam, Nushin; Eftekhari, Mehdi; Jafarpishe, Saleh

    2013-01-01

    Tracheal chondrosarcoma is a rare malignant mesenchymal tumor and there are less than 15 reports in the literature. We report a rare case of laryngotracheal chondrosarcoma in a 74-year-old man. He gave a history of radioiodine therapy for thyroid papillary carcinoma about 24 years ago. Diagnostic steps, histological presentation, and therapy are described in detail.

  16. PM 2.5 CHEMICAL SPECIATION SAMPLER EVALUATION FIELD PROGRAM: RESULTS FROM THE FOUR CITY STUDY

    EPA Science Inventory

    The objective of this sampler intercomparison field study is to determine the performance characteristics for the collection of the chemical components of PM2.5 by the chemical speciation monitors developed for the national network relative to each other, to the Federal Referen...

  17. Variation in the use of definitive treatment options in the management of Graves' disease: a UK clinician survey.

    PubMed

    Hookham, Jessica; Collins, Emma E; Allahabadia, Amit; Balasubramanian, Sabapathy P

    2017-04-01

    Graves' disease can be treated with antithyroid drugs (ATDs), radioiodine or surgery. Use of definitive treatments (radioiodine or surgery) varies widely across centres. Specific clinical circumstances, local facilities, patient and clinician preferences and perceptions will affect the choice of treatment. Detailed understanding of UK clinicians' views and their rationale for different treatments is lacking. To study the preferences and perceptions of UK clinicians on the role of surgery and radioiodine in the management of Graves' disease. 'British Thyroid Association' (BTA), 'Society for Endocrinology' (SFE) and 'British Association of Endocrine and Thyroid Surgeons' (BAETS) members were invited to complete an online survey examining their management decisions in Graves' disease and factors that influenced their decisions. 158 responses from UK consultants were included. The ratio of physicians to surgeons was 11:5 and males to females was 12:4. Most clinicians would commence ATDs in uncomplicated first presentation of Graves' disease. A wide range of risk estimates on the effectiveness and risks of treatment was given by clinicians. Radioiodine was used most frequently in relapsed Graves' disease. However, severe eye disease and pregnancy strongly influenced choice in favour of surgery. Surgeons underestimated the success of radioiodine (p<0.01) and were more likely to recommend thyroidectomy than physicians. This survey demonstrates significant variation in clinicians' perceptions of risks of treatment and their choice of management options for relapsed Graves' disease. The variation appeared to be dependent on patient and disease-specific factors as well as physician experience, gender and specialty. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Re-induction of cell differentiation and (131)I uptake in dedifferentiated FTC-133 cell line by TSHR gene transfection.

    PubMed

    Feng, Fang; Wang, Hui; Hou, Shasha; Fu, Hongliang

    2012-11-01

    Radioiodine therapy is commonly used to treat differentiated thyroid cancer (DTC), but a major challenge is dedifferentiation of DTC with the loss of radioiodine uptake. TSHR is a key molecule regulating thyrocyte proliferation and function. This study aimed to test the therapeutic potential of TSHR in dedifferentiated DTC by gene transfection in order to restore cell differentiation and radioiodine uptake. Dedifferentiated FTC-133 (dFTC-133) cells were obtained by monoclonal culture of FTC-133 cell line after (131)I radiation. Recombinant plasmid pcDNA3.1-hTSHR was transfected into dFTC-133 cells by using Lipofectamine 2000 reagent. Immunofluorescence analysis was carried out to confirm TSHR expression and its location. Radioiodine uptake assay was thereafter investigated. mRNAs and proteins of TSHR and other thyroid differentiated markers were detected by real-time PCR and western blot respectively. Among the thyroid specific genes in dFTC-133 cells with stable low radioiodine uptake, TSHR was down-regulated most significantly compared with FTC-133. Then, after TSHR gene transfection, augmented expression of TSHR was observed in dFTC-133 cell surface and cytoplasm by immunofluorescence analysis. It was found that (125)I uptake was 2.9 times higher (t=28.63, P<.01) in cells with TSHR transfection than control. The mRNAs of TSHR, NIS, TPO and Tg were also significantly increased by 1.7 times (t=13.8, P<.05), 4 times (t=28.52, P<.05), 1.5 times (t=14.43, P<.05) and 2.2 times (t=19.83, P<.05) respectively compared with control group. Decreased TSHR expression correlated with FTC-133 ongoing dedifferentiation. TSHR transfection contributed to the re-differentiation of dedifferentiated thyroid follicular carcinoma cells. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Childhood thyroid radioiodine exposure and subsequent infertility in the intermountain fallout cohort.

    PubMed

    Stone, Mary Bishop; Stanford, Joseph B; Lyon, Joseph L; VanDerslice, James A; Alder, Stephen C

    2013-01-01

    Above-ground and underground nuclear weapon detonation at the Nevada Test Site (1951-1992) has resulted in radioiodine exposure for nearby populations. Although the long-term effect of environmental radioiodine exposure on thyroid disease has been well studied, little is known regarding the effect of childhood radioiodine exposure on subsequent fertility. We investigated early childhood thyroid radiation exposure from nuclear testing fallout (supplied predominantly by radioactive isotopes of iodine) and self-reported lifetime incidence of male or female infertility or sterility. Participants were members of the 1965 Intermountain Fallout Cohort, schoolchildren at the time of exposure who were reexamined during two subsequent study phases to collect dietary and reproductive histories. Thyroid radiation exposure was calculated via an updated dosimetry model. We used multivariable logistic regression with robust sandwich estimators to estimate odds ratios for infertility, adjusted for potential confounders and (in separate models) for a medically confirmed history of thyroid disease. Of 1,389 participants with dosimetry and known fertility history, 274 were classified as infertile, including 30 classified as sterile. Childhood thyroid radiation dose was possibly associated with infertility [adjusted odds ratio (AOR) = 1.17; 95% CI: 0.82, 1.67 and AOR = 1.35; 95% CI: 0.96, 1.90 for the middle and upper tertiles vs. the first tertile of exposure, respectively]. The odds ratios were attenuated (AOR = 1.08; 95% CI: 0.75, 1.55 and AOR = 1.29; 95% CI: 0.91, 1.83 for the middle and upper tertiles, respectively) after adjusting for thyroid disease. There was no association of childhood radiation dose and sterility. Our findings suggest that childhood radioiodine exposure from nuclear testing may be related to subsequent adult infertility. Further research is required to confirm this.

  20. Investigation of factors influencing radioiodine (131I) biokinetics in patients with benign thyroid disease using nonlinear mixed effects approach.

    PubMed

    Topić Vučenović, Valentina; Rajkovača, Zvezdana; Jelić, Dijana; Stanimirović, Dragi; Vuleta, Goran; Miljković, Branislava; Vučićević, Katarina

    2018-05-13

    Radioiodine ( 131 I) therapy is the common treatment option for benign thyroid diseases. The objective of this study was to characterize 131 I biokinetics in patients with benign thyroid disease and to investigate and quantify the influence of patients' demographic and clinical characteristics on intra-thyroidal 131 I kinetics by developing a population model. Population pharmacokinetic analysis was performed using a nonlinear mixed effects approach. Data sets of 345 adult patients with benign thyroid disease, retrospectively collected from patients' medical records, were evaluated in the analysis. The two-compartment model of 131 I biokinetics representing the blood compartment and thyroid gland was used as the structural model. Results of the study indicate that the rate constant of the uptake of 131 I into the thyroid (k tu ) is significantly influenced by clinical diagnosis, age, functional thyroid volume, free thyroxine in plasma (fT 4 ), use of anti-thyroid drugs, and time of discontinuation of therapy before administration of the radioiodine (THDT), while the effective half-life of 131 I is affected by the age of the patients. Inclusion of the covariates in the base model resulted in a decrease of the between subject variability for k tu from 91 (3.9) to 53.9 (4.5)%. This is the first population model that accounts for the influence of fT 4 and THDT on radioiodine kinetics. The model could be used for further investigations into the correlation between thyroidal exposure to 131 I and the outcome of radioiodine therapy of benign thyroid disease as well as the development of dosing recommendations.

  1. Effects of skeleton structure on necrosis targeting and clearance properties of radioiodinated dianthrones.

    PubMed

    Zhang, Dongjian; Jiang, Cuihua; Yang, Shengwei; Gao, Meng; Huang, Dejian; Wang, Xiaoning; Shao, Haibo; Feng, Yuanbo; Sun, Ziping; Ni, Yicheng; Zhang, Jian; Yin, Zhiqi

    2016-01-01

    Necrosis avid agents (NAAs) can be used for diagnose of necrosis-related diseases, evaluation of therapeutic responses and targeted therapeutics of tumor. In order to probe into the effects of molecular skeleton structure on necrosis targeting and clearance properties of radioiodinated dianthrones, four dianthrone compounds with the same substituents but different skeletal structures, namely Hypericin (Hyp), protohypericin (ProHyp), emodin dianthrone mesomer (ED-1) and emodin dianthrone raceme (ED-2) were synthesized and radioiodinated. Then radioiodinated dianthrones were evaluated in vitro for their necrosis avidity in A549 lung cancer cells untreated and treated with H2O2. Their biodistribution and pharmacokinetic properties were determined in rat models of induced necrosis. In vitro cell assay revealed that destruction of rigid skeleton structure dramatically reduced their necrosis targeting ability. Animal studies demonstrated that destruction of rigid skeleton structure dramatically reduced the necrotic tissue uptake and speed up the clearance from the most normal tissues for the studied compounds. Among these (131)I-dianthrones, (131)I-Hyp exhibited the highest uptake and persistent retention in necrotic tissues. Hepatic infarction could be clearly visualized by SPECT/CT using (131)I-Hyp as an imaging probe. The results suggest that the skeleton structure of Hyp is the lead structure for further structure optimization of this class of NAAs.

  2. Investigation of public exposure resulted from the radioiodine delay tank facility of nuclear medicine department

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yusof, Mohd Fahmi Mohd, E-mail: mfahmi@usm.my; Ali, Abdul Muhaimin Mat; Abdullah, Reduan

    The study is carried out to assess the exposure rate that could contribute to public exposure in a radioiodine ward delay tank facility of Radiotherapy, Oncology and Nuclear Medicine, Department, Hospital Universiti Sains Malaysia (HUSM). The exposure rate at several locations including the delay tank room, doorway and at the public walking route was measured using Victoreen 415P-RYR survey meter. The radioactive level of the {sup 131}I waste was measured using Captus 3000 well counting system. The results showed that exposure rate and total count of the delay tank sample increased when the radioiodine ward was fully occupied with patientmore » and reduced when the ward was vacant. Occupancy of radioiodine ward for two consecutive weeks had dramatically increased the exposure rate around the delay tank and radioactive level of {sup 131}I waste. The highest exposure rate and radioactive level was recorded when the ward was occupied for two consecutive weeks with 177.00 µR/h and 58.36 kcpm respectively. The exposure rate decreased 15.76 % when the door of the delay tank room was closed. The exposure rate at public walking route decreased between 15.58 % and 36.92 % as the distance increased between 1 and 3 m.« less

  3. THE RESULTS OF USING RADIOIODINE FOR STUDIES OF THE FUNCTIONAL STATE OF THE THYROID GLAND IN CARDIOVASCULAR AND ALIMENTARY DISEASES (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalyuzhnii, I.T.

    1962-04-01

    The thyroid function in 60 healthy persons and 2000 patients was assessed. An elevated capacity of the thyroid gland to concentrate radioiodine was observed in almost 50% of rheumocarditis patients, one-third of lamblious cholecystitis cases, one-fourth of patients with rheumatic disease of the heart and circulatory insufficiency of the 1st and 2nd degrees, and more rarely in patients with neurosis, peptic ulcer, and hypertensive vascular disease of the 1st stage. Moderately low indexes of radioiodine accumulation in the thyroid gland were found in patients with subacute septic endocarditis, in two-thirds of patients with atherosclerosis and hypertensive vascular disease (2nd andmore » 3rd stages), in half of cases with rheumatic heart disease and circulatory insufficiency of the 3rd degree, as well as in pulmonary heart, chronic gastritis, and ulcerous disease. (auth)« less

  4. Development of Tethered Hsp90 Inhibitors Carrying Radioiodinated Probes to Specifically Discriminate and Kill Malignant Breast Tumor Cells

    DTIC Science & Technology

    2016-05-01

    both active (5) and inactive (12) probes. To obtain a control compound with very similar physical properties but lacking the ability to bind to Hsp90...procedure was developed and then adapted and modified to provide workable protocols for radioiodination. An inactive control molecule was also developed...955-959. 4. Impact. The successful synthesis of both and active and inactive tethered Hsp90 carrying iodine that can be successfully

  5. Depositional fluxes and residence time of atmospheric radioiodine (131I) from the Fukushima accident.

    PubMed

    Yang, Weifeng; Guo, Laodong

    2012-11-01

    Activities of radioiodine ((131)I) along with (210)Pb and (210)Po in time series precipitation samples were measured to determine the depositional fluxes of (131)I in the Southern United States and its removal rate and residence time in the atmosphere during the Fukushima nuclear accident. Radioiodine released from the Fukushima accident reached the Southern United States within 11 days, giving rise to a concurrent (131)I peak and anomalous (210)Po/(210)Pb ratios in the precipitation samples. The cumulative (131)I depositional flux was 4.6 ± 0.2 Bq m(-2) during the maximum fallout. The removal rate of (131)I out of the atmosphere, derived from a definite (131)I integral model, ranged from 0.03 to 0.14 d(-1) with an average of 0.08 ± 0.02 d(-1), which corresponds to a residence time of (131)I in the atmosphere of 12 ± 3 days, consistent with the resident timescale constrained by the (210)Po/(210)Pb disequilibrium technique. These results support our hypothesis that radioiodine was removed from the atmosphere by precipitation within two weeks. It seemed that regions reachable by (131)I transport within two weeks from Fukushima Japan would receive much more fallout, whereas places outside that distance would be relatively less polluted with radionuclides. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Effective doses to family members of patients treated with radioiodine-131

    NASA Astrophysics Data System (ADS)

    Zdraveska Kocovska, M.; Vaskova, O.; Majstorov, V.; Kuzmanovska, S.; Pop Gjorceva, D.; Spasic Jokic, V.

    2011-09-01

    The purpose of this study was to evaluate the effective dose to family members of thyroid cancer and hyperthyroid patients treated with radioiodine-131, and also to compare the results with dose constraints proposed by the International Commission of Radiological Protection (ICRP) and the Basic Safety Standards (BSS) of the International Atomic Energy Agency (IAEA). For the estimation of the effective doses, sixty family members of sixty patients, treated with radioiodine-131, and thermoluminiscent dosimeters (Model TLD 100) were used. Thyroid cancer patients were hospitalized for three days, while hyperthyroid patients were treated on out-patient basis. The family members wore TLD in front of the torso for seven days. The radiation doses to family members of thyroid cancer patients were well below the recommended dose constraint of 1 mSv. The mean value of effective dose was 0.21 mSv (min 0.02 - max 0.51 mSv). Effective doses, higher than 1 mSv, were detected for 11 family members of hyperthyroid patients. The mean value of effective dose of family members of hyperthyroid patients was 0.87 mSv (min 0.12 - max 6.79). The estimated effective doses to family members of hyperthyroid patients were higher than the effective doses to family members of thyroid carcinoma patients. These findings may be considered when establishing new national guidelines concerning radiation protection and release of patients after a treatment with radioiodine therapy.

  7. INTERCOMPARISON OF OPTICAL REMOTE SENSING SYSTEMS FOR ROADSIDE MEASUREMENTS

    EPA Science Inventory

    The presentation describes results of an intercomparison of three optical remote sensing systems for measurements of nitric oxide emitted from passenger cars and light-duty trucks. The intercomparison included a standards comparison to establish comparability of standards, follo...

  8. Inter-comparison of hydro-climatic regimes across northern catchments: snychronicity, resistance and resilience

    Treesearch

    Sean K. Carey; Doerthe Tetzlaff; Jan Seibert; Chris Soulsby; Jim Buttle; Hjalmar Laudon; Jeff McDonnell; Kevin McGuire; Daniel Caissie; Jamie Shanley; Mike Kennedy; Kevin Devito; John W. Pomeroy

    2010-01-01

    The higher mid-latitudes of the Northern Hemisphere are particularly sensitive to climate change as small differences in temperature determine frozen ground status, precipitation phase, and the magnitude and timing of snow accumulation and melt. An international inter-catchment comparison program, North-Watch, seeks to improve our understanding of the sensitivity of...

  9. Intercomparison of Clean Air Status and Trends Network (CASTNET) NO3 - and HNO3 Measurements with Data from Other Monitoring Programs

    EPA Science Inventory

    The EPA Clean Air Status and Trends Network (CASTNET) utilizes an open face filter pack system to measure concentrations of atmospheric sulfur and nitrogen species. The purpose of this study was to estimate the uncertainty in seasonal and annual concentrations of HNO3, NO3 - , ...

  10. Five months' follow-up of patients with and without iodine-positive lymph node metastases of thyroid carcinoma as disclosed by (131)I-SPECT/CT at the first radioablation.

    PubMed

    Schmidt, Daniela; Linke, Rainer; Uder, Michael; Kuwert, Torsten

    2010-04-01

    In differentiated thyroid carcinoma (DTC), (131)I-SPECT/CT is more accurate in identifying radioiodine-positive lymph node metastases (LNM) than planar whole-body scans (WBS). The purpose of this study was to investigate the value of (131)I-SPECT/CT performed at the first radioablation to predict the occurrence and/or persistence of cervical radioiodine-positive LNM 5 months later. The study included 81 DTC patients that had had SPECT/ spiral CT after radioablation of thyroid remnants after thyroidectomy. The patients were re-examined 5 months later using (131)I-WBS performed at TSH stimulation. In addition, SPECT/CT of the neck was performed in patients with iodine-positive cervical foci to distinguish between thyroid remnant and LNM. The outcome variable of the study was the detection or exclusion of iodine-positive cervical LNM. Of 61 patients without a SPECT/CT diagnosis of (131)I-positive LNM at radioablation, 60 had no (131)I-positive LNM at follow-up. In the remaining patient of this group, a new radioiodine-positive LNM was detected. In 17 of 20 patients with a SPECT/CT diagnosis of (131)I-positive LNM (n = 19) or an indeterminate lesion (n = 1) at first radioablation, no (131)I-positive LNM were detected 5 months later. Radioiodine-positive LNM persisted in three patients of this group. (131)I-SPECT/CT has a high negative predictive value with regard to the occurrence of radioiodine-positive cervical LNM 5 months after initial therapy. The majority of iodine-positive LNM diagnosed by SPECT/CT at radioablation disappear within 5 months. These findings motivate further research into the value of (131)I-SPECT/CT of the neck for predicting recurrence and planning surgical reintervention in DTC.

  11. Thyroid cancer following exposure to radioactive iodine.

    PubMed

    Robbins, J; Schneider, A B

    2000-04-01

    The thyroid gland is one of the most sensitive organs for radiation-induced oncogenesis and the magnitude of the risk from external radiation is well understood. This is not the case for internal radiation derived from the radioiodines, a matter of practical importance because of medical use and potential accidental exposure. This article reviews current knowledge derived from the follow-up of patients receiving diagnostic or therapeutic 131I and populations exposed to radioactive fallout. The latter includes the nuclear power station accident at Chernobyl and the results of atomic bomb development and testing at Hanford, the Nevada Test Site and the Marshall Islands. The most cogent information comes from Chernobyl where an epidemic of childhood thyroid cancer has followed exposure to radioiodine that was mainly 131I. Although much has been learned from this experience about the nature of radioiodine induced thyroid cancer in young children, the reconstruction of thyroid radiation doses is too preliminary to provide accurate knowledge of the risk in comparison to that from external radiation. In the Marshall Islands, much of the exposure was from short-lived radioiodines as well as external radiation, obviating the possibility to determine the risk from 131I. Exposure to 131I in the continental United States from atomic bomb testing is expected to have caused some thyroid cancers, but only in the immediate vicinity of the Nevada Test Site has any evidence of radiation-induced thyroid neoplasms been adduced. This evidence is minimally significant statistically, and not significant for thyroid cancer per se. Medical use of radioiodine has not been observed to cause thyroid cancer but very few of the patients studied were young children, the group most sensitive to thyroid radiation. Despite these limitations, this information is sufficient to make some suggestions concerning protective measures in the case of nuclear accidents and the follow up of individuals who have been exposed.

  12. A NTCP approach for estimating the outcome in radioiodine treatment of hyperthyroidism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strigari, L.; Sciuto, R.; Benassi, M.

    2008-09-15

    Radioiodine has been in use for over 60 years as a treatment for hyperthyroidism. Major changes in clinical practice have led to accurate dosimetry capable of avoiding the risks of adverse effects and the optimization of the treatment. The aim of this study was to test the capability of a radiobiological model, based on normal tissue complication probability (NTCP), to predict the outcome after oral therapeutic {sup 131}I administration. Following dosimetric study, 79 patients underwent treatment for hyperthyroidism using radioiodine and then 67 had at least a one-year follow up. The delivered dose was calculated using the MIRD formula, takingmore » into account the measured maximum uptake of administered iodine transferred to the thyroid, U0, and the effective clearance rate, T{sub eff} and target mass. The dose was converted to normalized total dose delivered at 2 Gy per fraction (NTD{sub 2}). Furthermore, the method to take into account the reduction of the mass of the gland during radioiodine therapy was also applied. The clinical outcome and dosimetric parameters were analyzed in order to study the dose-response relationship for hypothyroidism. The TD{sub 50} and m parameters of the NTCP model approach were then estimated using the likelihood method. The TD{sub 50}, expressed as NTD{sub 2}, resulted in 60 Gy (95% C.I.: 45-75 Gy) and 96 Gy (95% C.I.: 86-109 Gy) for patients affected by Graves or autonomous/multinodular disease, respectively. This supports the clinical evidence that Graves' disease should be characterized by more radiosensitive cells compared to autonomous nodules. The m parameter for all patients was 0.27 (95% C.I.: 0.22-0.36). These parameters were compared with those reported in the literature for hypothyroidism induced after external beam radiotherapy. The NTCP model correctly predicted the clinical outcome after the therapeutic administration of radioiodine in our series.« less

  13. Radioiodine therapy in Graves' disease based on tissue-absorbed dose calculations: effect of pre-treatment thyroid volume on clinical outcome.

    PubMed

    Reinhardt, Michael J; Brink, Ingo; Joe, Alexius Y; Von Mallek, Dirk; Ezziddin, Samer; Palmedo, Holger; Krause, Thomas M

    2002-09-01

    This study was performed with three aims. The first was to analyse the effectiveness of radioiodine therapy in Graves' disease patients with and without goitres under conditions of mild iodine deficiency using several tissue-absorbed doses. The second aim was to detect further parameters which might be predictive for treatment outcome. Finally, we wished to determine the deviation of the therapeutically achieved dose from that intended. Activities of 185-2,220 MBq radioiodine were calculated by means of Marinelli's formula to deliver doses of 150, 200 or 300 Gy to the thyroids of 224 patients with Graves' disease and goitres up to 130 ml in volume. Control of hyperthyroidism, change in thyroid volume and thyrotropin-receptor antibodies were evaluated 15+/-9 months after treatment for each dose. The results were further evaluated with respect to pre-treatment parameters which might be predictive for therapy outcome. Thyroidal radioiodine uptake was measured every day during therapy to determine the therapeutically achieved target dose and its coefficient of variation. There was a significant dose dependency in therapeutic outcome: frequency of hypothyroidism increased from 27.4% after 150 Gy to 67.7% after 300 Gy, while the frequency of persistent hyperthyroidism decreased from 27.4% after 150 Gy to 8.1% after 300 Gy. Patients who became hypothyroid had a maximum thyroid volume of 42 ml and received a target dose of 256+/-80 Gy. The coefficient of variation for the achieved target dose ranged between 27.7% for 150 Gy and 17.8% for 300 Gy. When analysing further factors which might influence therapeutic outcome, only pre-treatment thyroid volume showed a significant relationship to the result of treatment. It is concluded that a target dose of 250 Gy is essential to achieve hypothyroidism within 1 year after radioiodine therapy in Graves' disease patients with goitres up to 40 ml in volume. Patients with larger goitres might need higher doses.

  14. Field test to intercompare carbon monoxide, nitric oxide and hydroxyl instrumentation at Wallops Island, Virginia

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Beck, Sherwin M.; Bendura, Richard J.

    1987-01-01

    Documentation of the first of three instrument intercomparisons conducted as part of NASA Global Tropospheric Experiment/Chemical Instrumentation Test and Evaluation (GTE/CITE-1) is given. This ground-based intercomparison was conducted during July 1983 at NASA Wallops Flight Facility. Instruments intercompared included one laser system and three grab-sample approaches for CO; two chemiluminescent systems and one laser-induced fluorescent (LIF) technique for NO; and two different LIF systems and a radiochemical tracer technique for OH. The major objectives of this intercomparison was to intercompare ambient measurements of CO, NO, and OH at a common site by using techniques of fundamentally different detection principles and to identify any major biases among the techniques prior to intercomparison on an aircraft platform. Included in the report are comprehensive discussions of workshop requirements, philosophies, and operations as well as intercomparison analyses and results. In addition, the large body of nonintercomparison data incorporated into the workshop measurements is summarized. The report is an important source document for those interested in conducting similar large and complex intercomparison tests as well as those interested in using the data base for purposes other than instrument intercomparison.

  15. Instantaneous radioiodination of rose bengal at room temperature and a cold-kit therefor. [DOE patent application

    DOEpatents

    O'Brien, H. Jr.; Hupf, H.B.; Wanek, P.M.

    The disclosure relates to the radioiodination of rose bengal at room temperature and a cold-kit therefor. A purified rose bengal tablet is stirred into acidified ethanol at or near room temperature, until a suspension forms. Reductant-free /sup 125/I/sup -/ is added and the resulting mixture stands until the exchange label reaction occurs at room temperature. A solution of sterile isotonic phosphate buffer and sodium hydroxide is added and the final resulting mixture is sterilized by filtration.

  16. ABSORPTION OF I$sup 131$ BY THYROID GLAND IN ATHLETES DURING PHYSICAL EXERTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khorol, I.S.

    Radioiodine absorption by the thyroid gland after prolonged physical exercise (3000 m race) was studied in 16 athletes, aged 20 to 24 years. Two hours after administration of the isotope the level of its accumulation in the gland was halved. In 24 and 72 hours the content of radioiodine in the gland was higher than in experimental conditions without physical exercise. The phenomenon described evidently reflects the normal reaction of the thyroid gland of athletes to habitual physical exercise. (auth)

  17. Development of Tethered Hsp90 Inhibitors Carrying Radioiodinated Probes to Specifically Discriminate and Kill Malignant Breast Tumor Cells

    DTIC Science & Technology

    2017-05-01

    REPORT DATE : May 2017 TYPE OF REPORT: Annual PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012...currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE May 2017 2. REPORT TYPE Annual 3. DATES ... methods developed for stannylation of the molecule such that it can be effectively radioiodinated with either 131I or 124I. Two paths of synthesis

  18. Instantaneous radioiodination of rose bengal at room temperature and a cold kit therefor

    DOEpatents

    O'Brien, Jr., Harold A.; Hupf, Homer B.; Wanek, Philip M.

    1981-01-01

    The disclosure relates to the radioiodination of rose bengal at room temperature and a cold-kit therefor. A purified rose bengal tablet is stirred into acidified ethanol at or near room temperature, until a suspension forms. Reductant-free .sup.125 I.sup.- is added and the resulting mixture stands until the exchange label reaction occurs at room temperature. A solution of sterile isotonic phosphate buffer and sodium hydroxide is added and the final resulting mixture is sterilized by filtration.

  19. RESULTS FROM THE NORTH AMERICAN MERCURY MODEL INTER-COMPARISON STUDY (NAMMIS)

    EPA Science Inventory

    A North American Mercury Model Intercomparison Study (NAMMIS) has been conducted to build upon the findings from previous mercury model intercomparison in Europe. In the absence of mercury measurement networks sufficient for model evaluation, model developers continue to rely on...

  20. Accuracy of tretyakov precipitation gauge: Result of wmo intercomparison

    USGS Publications Warehouse

    Yang, Daqing; Goodison, Barry E.; Metcalfe, John R.; Golubev, Valentin S.; Elomaa, Esko; Gunther, Thilo; Bates, Roy; Pangburn, Timothy; Hanson, Clayton L.; Emerson, Douglas G.; Copaciu, Voilete; Milkovic, Janja

    1995-01-01

    The Tretyakov non-recording precipitation gauge has been used historically as the official precipitation measurement instrument in the Russian (formerly the USSR) climatic and hydrological station network and in a number of other European countries. From 1986 to 1993, the accuracy and performance of this gauge were evaluated during the WMO Solid Precipitation Measurement Intercomparison at 11 stations in Canada, the USA, Russia, Germany, Finland, Romania and Croatia. The double fence intercomparison reference (DFIR) was the reference standard used at all the Intercomparison stations in the Intercomparison. The Intercomparison data collected at the different sites are compatible with respect to the catch ratio (measured/DFIR) for the same gauge, when compared using mean wind speed at the height of the gauge orifice during the observation period.The Intercomparison data for the Tretyakov gauge were compiled from measurements made at these WMO intercomparison sites. These data represent a variety of climates, terrains and exposures. The effects of environmental factors, such as wind speed, wind direction, type of precipitation and temperature, on gauge catch ratios were investigated. Wind speed was found to be the most important factor determining the gauge catch and air temperature had a secondary effect when precipitation was classified into snow, mixed and rain. The results of the analysis of gauge catch ratio versus wind speed and temperature on a daily time step are presented for various types of precipitation. Independent checks of the correction equations against the DFIR have been conducted at those Intercomparison stations and a good agreement (difference less than 10%) has been obtained. The use of such adjustment procedures should significantly improve the accuracy and homogeneity of gauge-measured precipitation data over large regions of the former USSR and central Europe.

  1. Stratospheric Ozone Intercomparison Campaign (STOIC) 1989: Overview

    NASA Technical Reports Server (NTRS)

    Margitan, J. J.; Barnes, R. A.; Brothers, G. B.; Butler, J.; Burris, J.; Connor, B. J.; Ferrare, R. A.; Kerr, J. B.; Komhyr, W. D.; McCormick, M. P.; hide

    1995-01-01

    The NASA Upper Atmosphere Research Program organized a Stratospheric Ozone Intercomparison Campaign (STOIC) held in July-August 1989 at the Table Mountain Facility (TMF) of the Jet Propulsion Laboratory (JPL). The primary instruments participating in this campaign were several that had been developed by NASA for the Network for the Detection of Stratospheric Change: the JPL ozone lidar at TMF, the Goddard Space Flight Center trailer-mounted ozone lidar which was moved to TMF for this comparison, and the Millitech/LaRC microwave radiometer. To assess the performance of these new instruments, a validation/intercomparison campaign was undertaken using established techniques: balloon ozonesondes launched by personnel from the Wallops Flight Facility and from NOAA Geophysical Monitoring for Climate Change (GMCC) (now Climate Monitoring and Diagnostics Laboratory), a NOAA GMCC Dobson spectrophotometer, and a Brewer spectrometer from the Atmospheric Environment Service of Canada, both being used for column as well as Umkehr profile retrievals. All of these instruments were located at TMF and measurements were made as close together in time as possible to minimize atmospheric variability as a factor in the comparisons. Daytime rocket measurements of ozone were made by Wallops Flight Facility personnel using ROCOZ-A instruments launched from San Nicholas Island. The entire campaign was conducted as a blind intercomparison, with the investigators not seeing each others data until all data had been submitted to a referee and archived at the end of the 2-week period (July 20 to August 2, 1989). Satellite data were also obtained from the Stratospheric Aerosol and Gas Experiment (SAGE 2) aboard the Earth Radiation Budget Satellite and the Total Ozone Mapping Spectrometer (TOMS) aboard Nimbus 7. An examination of the data has found excellent agreement among the techniques, especially in the 20- to 40-km range. As expected, there was little atmospheric variability during the intercomparison, allowing for detailed statistical comparisons at a high level of precision. This overview paper summarizes the campaign and provides a 'road map' to subsequent papers in this issue by the individual instrument teams which will present more detailed analysis of the data and conclusions.

  2. Operational overview of NASA GTE/CITE 1 airborne instrument intercomparisons - Carbon monoxide, nitric oxide, and hydroxyl instrumentation. [Global Tropospheric Experiment/Chemical Instrumentation Test and Evaluation

    NASA Technical Reports Server (NTRS)

    Beck, Sherwin M.; Bendura, Richard J.; Mcdougal, David S.; Hoell, James M., Jr.; Gregory, Gerald L.; Sachse, Glen W.; Hill, Gerald F.; Curfman, Howard J., Jr.; Torres, Arnold L.; Condon, Estelle P.

    1987-01-01

    An overview of the airborne intercomparisons of CO, NO, and OH instrumentation is presented in this first paper of the series on the NASA Global Tropospheric Experiment/Chemical Instrumentation Test and Evaluation (GTE/CITE 1). This paper provides the reader with background information about several important characteristics of the project. These include the overall objectives and approach, the measurements taken, the intercomparison protocol, aircraft platform, profiles of each aircraft flight, and the participants. A synopsis of the overall results of the CO, NO, and OH instrument intercomparisons is also included. Companion papers discuss the detailed results of the CO and NO intercomparison tests as well as pertinent scientific findings.

  3. The agricultural model intercomparison and improvement project (AgMIP): Protocols and pilot studies

    USDA-ARS?s Scientific Manuscript database

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) is a distributed climate-scenario simulation research activity for historical period model intercomparison and future climate change conditions with participation of multiple crop and agricultural economic model groups around the...

  4. Metabolic comparison of radiolabeled aniline- and phenol-phthaleins with (131)I.

    PubMed

    Avcibaşi, Uğur; Avcibaşi, Nesibe; Unak, Turan; Unak, Perihan; Müftüler, Fazilet Zümrüt; Yildirim, Yeliz; Dinçalp, Haluk; Gümüşer, Fikriye Gül; Dursun, Ebru Rükşen

    2008-05-01

    The metabolic comparison of aniline- and phenol-phthaleins radiolabeled with (131)I ((131)I-APH and (131)I-PPH, respectively) has been investigated in this study. To compare the metabolic behavior of these phthaleins and their glucuronide conjugates radiolabeled with (131)I, scintigraphic and biodistributional techniques were applied using male Albino rabbits. The results obtained have shown that these compounds were successfully radioiodinated with a radioiodination yield of about 100%. Maximum uptakes of (131)I-APH and (131)I-PPH, which were metabolized as N- and O-glucuronides, were observed within 2 h in the bladder and in the small intestine, respectively. In the case of verification of considerably up taking of these compounds also by tumors developed in the small intestine and in the bladder tissues, these results can be expected to be encouraging to test these compounds, which will be radiolabeled with other radioiodines such as (125)I, (123)I and (124)I as imaging and therapeutic agents in nuclear medical applications.

  5. Long-term follow-up in toxic solitary autonomous thyroid nodules treated with radioactive iodine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huysmans, D.A.; Corstens, F.H.; Kloppenborg, P.W.

    1991-01-01

    The long-term effects of radioiodine treatment on thyroid function in patients with a toxic solitary autonomous thyroid nodule were evaluated. Fifty-two patients received a therapeutic dose of 20 mCi of iodine-131 ({sup 131}I). Duration of follow-up was 10 +/- 4 yr. Follow-up data included a biochemical evaluation of thyroid function. The failure rate (recurrent hyperthyroidism) was 2%. The incidence of hypothyroidism was 6% and was not related to the dose per gram of nodular tissue. Oral administration of 20 mCi of radioiodine is a simple and highly effective method for the treatment of patients with a toxic autonomous thyroid nodule.more » The risk of development of hypothyroidism is low if extranodular uptake of {sup 131}I is prevented. This can be achieved by not treating euthyroid patients, by no longer using injections of exogenous thyroid stimulating hormone in the diagnostic work-up of the patients and by always performing radioiodine imaging shortly before treatment.« less

  6. Prevention of Graves' ophthalmopathy.

    PubMed

    Bartalena, Luigi

    2012-06-01

    Smoking is the most important risk factor for the occurrence/progression of Graves' ophthalmopathy (GO), as well as for its lower/slower response to immunosuppression. Accordingly, refrain from smoking should be urged, both as primary prevention (removal of risk factors in Graves' patients without GO), secondary prevention (early detection and treatment of asymptomatic/very mild GO) and tertiary prevention (reduction of complications/disability of overt GO). A 6-month course of 200 μg/day sodium selenite can prevent progression of mild GO to more severe GO and is, therefore, a form of secondary prevention and, probably, primary prevention. Correction of thyroid dysfunction and stable maintenance of euthyroidism are important preventive measures. The optimal treatment for hyperthyroidism in patients with GO is uncertain, because evidence demonstrating the superiority of antithyroid drugs over thyroid ablation (radioiodine, thyroidectomy, or both) is lacking. If radioiodine is used, low-dose steroid prophylaxis is recommended, particularly in smokers, to prevent radioiodine-associated GO progression. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Lactoperoxidase catalyzed radioiodination of cell surface immunoglobulin: incorporated radioactivity may not reflect relative cell surface Ig density. [/sup 125/I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilder, R.L.; Yuen, C.C.; Mage, R.G.

    1979-02-01

    Rabbit and mouse splenic lymphocytes were radioiodinated by the lactoperoxidase technique, extracted with non-ionic detergent, immunoprecipitated with high titered rabbit anti-kappa antisera, and compared by SDS-PAGE. Mouse sIg peaks were reproducibly larger in size than rabbit sIg peaks (often greater than 10 times). Neither differences in incorporation of label into the rabbit cell surface, nor differences in average sIg density explain this result. Total TCA-precipitable radioactivity was similar in each species. Estimation of the relative amounts of sIg in the mouse and rabbit showed similar average sIg densities. Differences in detergent solubility, proteolytic lability, or antisera used also do notmore » adequately account for this difference. Thus, these data indicate that radioactivity incorporated after lactoperoxidase catalyzed cell surface radioiodination may not reflect cell surface Ig density. Conclusions about cell surface density based upon relative incorporation of radioactivity should be confirmed by other approaches.« less

  8. Giving radioiodine? Think about airport security alarms.

    PubMed

    Kaniuka-Jakubowska, S; Lewczuk, A; Mizan-Gross, K; Obołończyk, L; Lass, P; Sworczak, K

    2012-01-01

    An increased sensitivity of airport detectors, a growing number of isotopic tests, and globalization of the society have raised a number of false positive radioactive alarms at airports and public places. This paper presents two new cases of patients who triggered airport security alarms after receiving 740MBq of (131)I for non-toxic goitre and attempts to compare surprisingly limited literature concerning this problem. A 57-year-old man triggered a security alarm at three different airports on the 17th, 28th, and 31st day after radioiodine exposure. Interestingly enough, in the meantime, on the 18th and 22nd day, no radiation was detected in him at the airport where he was twice detained as a source of radiation later on. The second case presents a 45-year-old woman who activated security alarm detectors while crossing a border on her coach trip 28 days after radioiodine administration. Copyright © 2011 Elsevier España, S.L. and SEMNIM. All rights reserved.

  9. Iodine-131 Therapy and Nasolacrimal Duct Obstructions: What We Know and What We Need to Know.

    PubMed

    Ali, Mohammad Javed

    2016-01-01

    The aims of the current review are to summarize the etiopathogenesis, symptomatology, management, complications, and outcomes of iodine-131-induced nasolacrimal duct obstructions, to propose a screening protocol and elucidate the potential avenues of future research. The authors performed an electronic database (PubMed, MEDLINE, EMBASE, and Cochrane Library) search of all articles published in English on nasolacrimal duct obstructions following radioiodine therapy. These articles were reviewed along with their relevant cross references. Data reviewed included demographics, presentations, investigations, management, complications, and outcomes. In addition, based on relevant unanswered questions and current lacunae in literature, potential avenues for further research have been elucidated. The frequency of nasolacrimal duct obstruction is reported to range from 2.2% to 18% following I-131 therapy. They are mostly bilateral and noted in patients who receive more than 150 mCi radioiodine. Exact etiopathogenesis is unknown but radiotoxicity to lacrimal sac and nasolacrimal duct is believed to be mediated through a sodium-iodine symporter protein. Although uncommon, it is important to increase awareness among treating physicians and patients receiving radioiodine therapy about the potential side effect of nasolacrimal duct obstruction. Imaging modalities are useful adjuncts in the diagnosis. Dacryocystorhinostomy is the most common modality of management with good outcomes. Nasolacrimal duct obstruction following radioiodine treatment is a distinct clinical entity. Increased awareness would facilitate timely diagnosis, management, and an enhanced quality of life for the patients.

  10. Cost-effectiveness of using recombinant human thyroid-stimulating hormone before radioiodine ablation for thyroid cancer treatment in Spanish hospitals.

    PubMed

    Vallejo, J A; Muros, M A

    In thyroid cancer treatment, the thyroid-stimulating hormone (TSH) must be elevated before radioiodine ablation, either by exogenous (with recombinant human thyrotropin [rhTSH]) or endogenous stimulation by thyroid hormone withdrawal (THW). The use of rhTSH avoids hypothyroidism and favours the subsequent elimination of radioiodine, but involves the cost of the product. For this reason, a cost-effectiveness analysis was performed, taking into account all costs involved and the benefits associated with the use of this therapy. Using a Markov modelling with two analysis arms (rhTSH and THW), stratified into high (100mCi/3700 MBq) and low (30mCi/1110 MBq) radioiodine doses, and using 17 weekly cycles, the incremental cost per quality-adjusted life-year (QALY) related to the use of rhTSH was determined. The clinical inputs included in the model were based on published studies and in a treatment survey conducted in Spain. Radioablation preparation with rhTSH is superior to THW, showing additional benefits (0.048 AVAC), as well as cost savings (-€614.16), with an incremental cost-effectiveness rate (ICER) of -€12,795/QALY. The univariate and multivariate sensitivity analyses showed the result to be robust. The use of rhTSH previous to radioablation in Spain has cost savings, as well as a series of health benefits for the patient, making it highly cost-effective. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  11. Wake Sensor Evaluation Program and Results of JFK-1 Wake Vortex Sensor Intercomparisons

    NASA Technical Reports Server (NTRS)

    Barker, Ben C., Jr.; Burnham, David C.; Rudis, Robert P.

    1997-01-01

    The overall approach should be to: (1) Seek simplest, sufficiently robust, integrated ground based sensor systems (wakes and weather) for AVOSS; (2) Expand all sensor performance cross-comparisons and data mergings in on-going field deployments; and (3) Achieve maximal cost effectiveness through hardware/info sharing. An effective team is in place to accomplish the above tasks.

  12. A fluorescent radioiodinated oligonucleotidic photoaffinity probe for protein labeling: synthesis and photolabeling of thrombin.

    PubMed

    Berens, C; Courtoy, P J; Sonveaux, E

    1999-01-01

    To study the interactions between oligonucleotides and proteins, an original photoaffinity radiolabeling probe has been synthesized. Starting with a 5'-pyridyldithio-3'-amino-oligonucleotide, the photophore benzophenone was first coupled to the 3' end, through acylation by an activated ester of benzoylbenzoic acid. A fluorescein molecule was grafted by alkylation of the free 5'-SH. This compound was finally radiolabeled with 125I using IodoBeads. The selective photolabeling of thrombin in a complex protein mixture by the radioiodinated probe validates this strategy to identify oligonucleotide-binding proteins.

  13. Usefulness of 68Ga-DOTA-RGD (αvβ3) PET/CT Imaging in Thyroglobulin Elevation With Negative Iodine Scintigraphy.

    PubMed

    Vatsa, Rakhee; Shykla, Jaya; Mittal, Bhagwant Rai; Bhusari, Priya; Sood, Apurva; Basher, Rajender Kumar; Bhattacharya, Anish

    2017-06-01

    TENIS (thyroglobulin elevation with negative iodine scintigraphy) syndrome in patients with differentiated thyroid carcinoma is not a rare finding. In such patients, F-FDG PET/CT can help in disease evaluation. RGD tripeptide, used for imaging angiogenesis, may also help in disease detection in patients with negative radioiodine whole-body scan. We present 1 such case in whom Ga-RGD tripeptide imaging was helpful in disease detection in the setting of negative radioiodine whole-body scan.

  14. Comprehensive Australasian multicentre dosimetric intercomparison: issues, logistics and recommendations.

    PubMed

    Ebert, M A; Harrison, K M; Cornes, D; Howlett, S J; Joseph, D J; Kron, T; Hamilton, C S; Denham, J W

    2009-02-01

    The present paper describes the logistics of the 2004-2008 Australasian Level III Dosimetry Intercomparison. Dosimetric intercomparisons (or 'audits') can be used in radiotherapy to evaluate the accuracy and quality of radiation delivery. An intercomparison was undertaken in New Zealand and Australia to evaluate the feasibility and logistics of ongoing dosimetric intercomparisons that evaluate all steps in the radiotherapy treatment process, known as a 'Level III' intercomparison. The study commenced in 2002 with the establishment of a study team, definition of the study protocol, acquisition of appropriate equipment and recruitment of participating radiotherapy centres. Measurements were undertaken between October 2004 and March 2008, and included collation of data on time, costs and logistics of the study. Forty independent Australian and New Zealand radiotherapy centres agreed to participate. Measurement visits were made to 37 of these centres. Data is presented on the costs of the study and the level of support required. The study involved the participation of 16 staff at the study centre who invested over 4000 hours in the study, and of over 200 professionals at participating centres. Recommendations are provided for future phantom-based intercomparisons. It is hoped that the present paper will be of benefit to any centres or groups contemplating similar activities by identifying the processes involved in establishing the study, the potential hazards and pitfalls, and expected resource requirements.

  15. Uninhibited thyroidal uptake of radioiodine despite iodine excess in amiodarone-induced hypothyroidism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiersinga, W.M.; Touber, J.L.; Trip, M.D.

    1986-08-01

    Iodine excess is associated with a low thyroidal radioiodine uptake due to dilution of the radioisotope by the increased stable iodide pool. We studied thyroidal uptake of radioisotopes in cardiac patients with iodine excess due to amiodarone treatment. /sup 99m/Tc-pertechnetate scintigraphy was performed in 13 patients receiving long term amiodarone therapy. Five patients had a clearly visible thyroid gland, and 8 patients had no or a very faint thyroid image. All patients with positive scans had an increased plasma TSH level, whereas all patients with negative scans had a normal or absent TSH response to TRH. Thyroidal uptake and dischargemore » of 123I were studied in 30 other patients. Group I (n = 11) had normal plasma TSH responses to TRH and no iodine excess, group II (n = 7) had normal TSH responses to TRH and excess iodine from metrizoate angiography in the previous month, group III (n = 7) had normal or decreased TSH responses to TRH while receiving long term amiodarone therapy, and group IV (n = 5) had increased TSH responses to TRH while receiving long term amiodarone therapy. The mean radioiodine uptake value in group I (5.4 +/- 0.8% (+/- SE) at 60 min) was higher than those in group II (2.3 +/- 0.7%; P = 0.009) and group III (0.8 +/- 0.3%; P = 0.0005), but not different from that in group IV (5.3 +/- 1.2%; P = NS). Radioiodine discharge after perchlorate (expressed as a percentage of the 60 min uptake) in group I (10.1 +/- 2.2%) was lower than those in group II (24.9 +/- 10.6%; P = 0.05) and group III (28.8 +/- 5.3%; P less than 0.005), whereas discharge in group IV (58.0 +/- 6.1%) was greater than those in group II (P less than 0.05) and group III (P less than 0.01). In conclusion, 1) thyroid visualization by /sup 99m/Tc-pertechnetate and thyroid radioiodine uptake during iodine excess are decreased in euthyroid and hyperthyroid patients, but preserved in hypothyroid patients.« less

  16. Radioiodine treatment of hyperthyroidism in a pregnant women.

    PubMed

    Berg, G E; Nyström, E H; Jacobsson, L; Lindberg, S; Lindstedt, R G; Mattsson, S; Niklasson, C A; Norén, A H; Westphal, O G

    1998-02-01

    We describe the effects of radioiodine treatment of a pregnant thyrotoxic woman. The woman received 500 MBq of (131)I in her 20th gestational week. The pregnancy was discovered 10 days after radioiodine administration. A gamma camera examination of the abdomen at that time showed a distinct focus of activity, which was interpreted as the fetal thyroid. Gamma camera examinations of the mother and fetus were performed at 10, 11, 12, 13 and 18 days after administration of the therapeutic activity and were the basis of dose calculations. The child was examined by hormone tests and mental performance tests, up to 8 yr after birth. The uptake at 24 hr postadministration was calculated to be 10 MBq (2%) in the fetal thyroid gland. The effective half-life was 2.5 days, giving a calculated absorbed dose to the fetal thyroid gland of 600 Gy, which is considered to be an ablative dose. The calculated absorbed dose to the fetal body, including brain, was about 100 mGy, and 40 mGy to the fetal gonads. Doses were estimated taking contributions from radioiodine in the mother, the fetal body and the fetal thyroid into consideration. The woman was encouraged to continue her pregnancy and received levothyroxine in a dose to render her slightly thyrotoxic. At full term, an apparently healthy boy, having markedly raised cord blood serum thyroid-stimulating hormone concentration and subnormal thyroxine (T4) and low-normal triiodothyronine (T3) concentrations, was born. Treatment with thyroxine was initiated from the age of 14 days, when the somatosensoric evoked potential latency time increased to a pathological value and hormonal laboratory tests repeatedly confirmed the hypothyroid state. At 8 yr of age, the child attends regular school. A neuropsychological pediatric examination showed that the mental performance was within normal limits, but with an uneven profile. He has a low attention score and displays evidently subnormal capacity regarding figurative memory. Radioiodine treatment in pregnancy in the 20th gestational week does not give a total absorbed dose to the fetal body that justifies termination of pregnancy. A high absorbed dose to the fetal thyroid, however, should be the basis of the management of the pregnancy and offspring.

  17. Food safety regulations: what we learned from the Fukushima nuclear accident.

    PubMed

    Hamada, Nobuyuki; Ogino, Haruyuki

    2012-09-01

    On 11 March 2011, the magnitude-9.0 earthquake and a substantial tsunami struck off the northeast coast of Japan. The Fukushima nuclear power plants were inundated and stricken, followed by radionuclide releases outside the crippled reactors. Provisional regulation values for radioactivity in food and drink were set on 17 March and were adopted from the preset index values, except that for radioiodines in water and milk ingested by infants. For radiocesiums, uranium, plutonium and transuranic α emitters, index values were defined in all food and drink not to exceed a committed effective dose of 5 mSv/year. Index values for radioiodines were defined not to exceed a committed equivalent dose to the thyroid of 50 mSv/year, and set in water, milk and some vegetables, but not in other foodstuffs. Index values were calculated as radioactive concentrations of indicator radionuclides ((131)I for radioiodines, (134)Cs and (137)Cs for radiocesiums) by postulating the relative radioactive concentration of coexisting radionuclides (e.g., (132)I, (133)I, (134)I, (135)I and (132)Te for (131)I). Surveys were thence conducted to monitor levels of (131)I, (134)Cs and (137)Cs. Provisional regulation values were exceeded in tap water, raw milk and some vegetables, and restrictions on distribution and consumption began on 21 March. Fish contaminated with radioiodines at levels of concern were then detected, so that the provisional regulation value for radioiodines in seafood adopted from that in vegetables were additionally set on 5 April. Overall, restrictions started within 25 days after the first excess in each food or drink item, and maximum levels were detected in leafy vegetables (54,100 Bq/kg for (131)I, and a total of 82,000 Bq/kg for (134)Cs and (137)Cs). This paper focuses on the logic behind such food safety regulations, and discusses its underlying issues. The outlines of the food monitoring results for 24,685 samples and the enforced restrictions will also be described. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. NRC TLD Direct Radiation Monitoring Network. Progress report, October--December 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Struckmeyer, R.

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1996. It provides the ambient radiation levels measured in the vicinity of 74 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program. 3 figs., 4 tabs.

  19. Thiamazole Pretreatment Lowers the (131)I Activity Needed to Cure Hyperthyroidism in Patients With Nodular Goiter.

    PubMed

    Kyrilli, Aglaia; Tang, Bich-Ngoc-Thanh; Huyge, Valérie; Blocklet, Didier; Goldman, Serge; Corvilain, Bernard; Moreno-Reyes, Rodrigo

    2015-06-01

    Relatively low radioiodine uptake (RAIU) represents a common obstacle for radioiodine ((131)I) therapy in patients with multinodular goiter complicated by hyperthyroidism. To evaluate whether thiamazole (MTZ) pretreatment can increase (131)I therapeutic efficacy. Twenty-two patients with multinodular goiter, subclinical hyperthyroidism, and RAIU < 50% were randomized to receive either a low-iodine diet (LID; n = 10) or MTZ 30 mg/d (n = 12) for 42 days. Thyroid function and 24-hour RAIU were measured before and after treatment. Thyroid volume was evaluated by either magnetic resonance imaging or single photon emission computed tomography. Mean 24-hour RAIU increased significantly from 32 ± 10% to 63 ± 18% in the MTZ group (P < .001). Consequently, there was a 31% decrease in the calculated median therapeutic (131)I activity after MTZ (P < .05). No significant changes in 24-hour RAIU were observed after diet. In the MTZ group, median serum TSH levels increased significantly by 9% and mean serum free T4 and free T3 concentrations decreased by 22% and 15%, respectively, whereas no changes in thyroid function were observed in the LID group. Thyroid volume did not significantly change in either of the two groups. At 12 months after radioiodine treatment, median serum TSH was within the normal range in both groups. MTZ treatment before (131)I therapy resulted in an average 2-fold increase in thyroid RAIU and enhanced the efficiency of radioiodine therapy assessed at 12 months. MTZ pretreatment is therefore a safe, easily accessible alternative to recombinant human TSH stimulation and a more effective option than LID.

  20. [Results of radioiodine therapy in different forms of hyperthyroidism in relation to the planned dosage].

    PubMed

    Moser, E

    1992-07-01

    The aim of this study was to assess the efficacy of radioiodine therapy (131J) in a large group (n = 925) of hyperthyroid patients treated at two major departments of nuclear medicine (Freiburg, abbr. FR, and Munich, abbr. M). 761 patients suffered from non-immunogenic hyperthyroidism (Plummer's disease) and the remaining 164 patients from immunogenic hyperthyroidism (Graves' disease). In these cases, radioiodine therapy using doses between 60 and 80 Gy proved ineffective, FR (80 Gy) recording 28% success and M (60 Gy) 54%. A dose of 150 Gy, however, is successful in more than 80% of the cases: FR 81%, M86%. However, the incidence rate of hypothyroidism increases consecutively with 150 Gy: FR 49%, M 62%. In patients suffering from Plummer's disease, the solitary autonomous nodule can be eliminated by radioiodine therapy (400 Gy) with a high rate of success (95%); the same applies to multinodular autonomous adenomas. The therapeutic concept applying a dose of 400 Gy to the total functional autonomous tissue (delineated by ultrasound) yields slightly better results (95%) than 150 Gy applied to thyroid gland (M88%, FR82%). This dosimetric compromise is a practicable alternative which is tolerably successful. In patients suffering from disseminated non-immunogenic hyperthyroidism, a dose of 150 Gy applied to the entire organ succeeds in 85% of the cases. The rate of hypothyroidism resulting from these dose recommendations is the lesser evil compared to residual or recurrent hyperthyroidism, since hypothyroid patients can be treated without any problem with thyroid hormones.

  1. Bronchoalveolar carcinoma of lung masquerading as iodine avid metastasis in a patient with minimally invasive follicular carcinoma of thyroid.

    PubMed

    Malhotra, Gaurav; Nair, Narendra; Menon, Hari; Gujral, Sumit; Abhyankar, Amit; Baghel, Nawab S; Awasare, Sushama; Nabar, Swapna J; Abhyankar, Suman; Kand, Purushottam G

    2008-01-01

    A 52-year-old man with follicular thyroid carcinoma was administered 182 mCi of radioiodine (I-131) a month after total thyroidectomy. Post-therapy scan revealed diffuse uptake of radioiodine in the apical left lung. CT-guided biopsy of this mass revealed mucinous bronchoalveolar carcinoma. Immunohistochemistry for thyroglobulin was negative. An FDG PET scan showed avid uptake in the lung mass. Surgery was ruled out, so he was given chemotherapy, without benefit. The lesion continued to show I-131 uptake even while on daily T3 substitution, suggesting that the mass was thyroid stimulating hormone-independent. Because the mass showed I-131 uptake and chemotherapy was not beneficial, it was decided to treat with I-131. He was continued on T3 substitution therapy and was given 209 mCi of I-131. Follow-up CT scan a few weeks later reported a 1-cm all round reduction of the mass. I-131 scan showed avid tracer uptake in the mass. This case suggests the possibility of this therapeutic option in nonthyroidal tumors that may concentrate radioiodine.

  2. Radioiodine therapy in elderly patients with subclinical hyperthyroidism due to non-voluminous nodular goiter and its effect on bone metabolism.

    PubMed

    Rosario, Pedro Weslley

    2013-03-01

    To evaluate 131I therapy in elderly patients with subclinical hyperthyroidism (SCH) due to nodular disease and who did not receive antithyroid drugs (ATDs), and the effect of the treatment on bone metabolism. Thirty-six patients with TSH ≤ 0.1 mIU/L and non-voluminous goiter (< 60 cm³) were studied. Bone mineral density (BMD) was assessed in 17 women with osteopenia. Mean 24-h 131I uptake was 17.5%. Symptoms of thyrotoxicosis were reported by two (5.5%) patients in the first week after therapy. One year after radioiodine treatment, SCH was resolved in 30 (83.3%) patients, and hypothyroidism was detected in one (2.7%). In the patients in whom TSH returned to normal, femoral and lumbar spine BMD increased by 1.9% and 1.6%, respectively, in average. In elderly patients with SCH and non-voluminous goiter, radioiodine not preceded by ATDs is a safe and effective therapeutic alternative. Resolution of SCH has beneficial effects on BMD in postmenopausal women with osteopenia.

  3. Intercomparison of hydrologic processes in global climate models

    NASA Technical Reports Server (NTRS)

    Lau, W. K.-M.; Sud, Y. C.; Kim, J.-H.

    1995-01-01

    In this report, we address the intercomparison of precipitation (P), evaporation (E), and surface hydrologic forcing (P-E) for 23 Atmospheric Model Intercomparison Project (AMIP) general circulation models (GCM's) including relevant observations, over a variety of spatial and temporal scales. The intercomparison includes global and hemispheric means, latitudinal profiles, selected area means for the tropics and extratropics, ocean and land, respectively. In addition, we have computed anomaly pattern correlations among models and observations for different seasons, harmonic analysis for annual and semiannual cycles, and rain-rate frequency distribution. We also compare the joint influence of temperature and precipitation on local climate using the Koeppen climate classification scheme.

  4. Airborne sulfur trace species intercomparison campaign: Sulfur dioxide, dimethylsulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Hoell, James M., Jr.; Davis, Douglas D.

    1991-01-01

    Results from an airborne intercomparison of techniques to measure tropospheric levels of sulfur trace gases are presented. The intercomparison was part of the NASA Global Tropospheric Experiment (GTE) and was conducted during the summer of 1989. The intercomparisons were conducted on the Wallops Electra aircraft during flights from Wallops Island, Virginia, and Natal, Brazil. Sulfur measurements intercompared included sulfur dioxide (SO2), dimethylsulfide (DMS), hydrogen sulfide (H2S), carbon disulfide (CS2), and carbonyl sulfide (OCS). Measurement techniques ranged from filter collection systems with post-flight analyses to mass spectrometer and gas chromatograph systems employing various methods for measuring and identifying the sulfur gases during flight. Sampling schedules for the techniques ranged from integrated collections over periods as long as 50 minutes to one- to three-minute samples every ten or fifteen minutes. Several of the techniques provided measurements of more than one sulfur gas. Instruments employing different detection principles were involved in each of the sulfur intercomparisons. Also included in the intercomparison measurement scenario were a host of supporting measurements (i.e., ozone, nitrogen oxides, carbon monoxide, total sulfur, aerosols, etc.) for purposes of: (1) interpreting results (i.e., correlation of any noted instrument disagreement with the chemical composition of the measurement environment); and (2) providing supporting chemical data to meet CITE-3 science objectives of studying ozone/sulfur photochemistry, diurnal cycles, etc. The results of the intercomparison study are briefly discussed.

  5. On the occurrence of hypothyroidism after radioiodine resection (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farschidpur, D.; Meiisel, P.

    1963-02-01

    An attempt was made to determine the dose of radioiodine in the treatment of hyperthyroidism with reference to the number of Cs and rep values. It was proved desirable to administer no more than 8 mC and 30,000 rep. An analysis of patients treated between 1956 and 1961 revealed six permanent cases of hypothyroidism; each had been treated with a greater dose than the above. The occurrence of hynofunction in cases treated with a dose greater than the above is compared statistically with cases treated with smaller doses. A number of examples are discussed.

  6. Struma Ovarii With Hyperthyroidism.

    PubMed

    Ang, Lynn P; Avram, Anca M; Lieberman, Richard W; Esfandiari, Nazanene H

    2017-06-01

    We report the case of a 61-year-old woman with persistent thyrotoxicosis for 7 years despite low thyroidal radioiodine uptake and methimazole treatment. Her initial I whole-body scan (WBS) was read as negative. Upon evaluation in our institution, she remained hyperthyroid after discontinuation of methimazole. Repeat WBS with SPECT/CT revealed low 24-hour thyroidal uptake (RAIU = 2%) and intensely focal radioiodine uptake in a large heterogeneous left pelvic mass, consistent with left adnexal struma ovarii. Resection of this mass confirmed benign struma ovarii. This case illustrates the advantage of fusion SPECT/CT imaging with planar I-WBS for diagnosis of extrathyroidal thyrotoxicosis.

  7. Pharmacokinetics and tissue distribution of parenterally administered human alpha-lymphotoxin in normal and meth-A tumor-bearing BALB/c mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Averbook, B.J.; Jeffes, E.B.; Yamamoto, R.S.

    1989-08-01

    These in vivo studies examine the pharmacokinetics of parenterally administered purified, native human alpha-lymphotoxin (LT) in normal and Meth-A bearing BALB/c mice. We found that the lytic activity of alpha-LT was inactivated within 5 h in the blood of both normal and tumor-bearing mice in vivo. However, LT bioactivity in vitro was not affected by incubation with fresh serum. Radioiodinated LT was rapidly sequestered in the kidneys of both normal and tumor-bearing animals. Systemically administered, radioiodinated LT did not selectively localize in tumor tissues.

  8. PROCEEDINGS OF THE CONFERENCE ON RADIOIODINE SPONSORED BY THE ARGONNE CANCER RESEARCH HOSPITAL, UNITED STATES ATOMIC ENERGY COMMISSION, AND THE CLINICS OF THE UNIVERSITY OF CHICAGO, NOVEMBER 5 AND 6, 1956, CHICAGO, ILLINOIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, D.E. ed.

    1958-10-31

    Applications of the various iodine isotopes in diagnosis and therapy are discussed. Problems of dosimetry and radiation exposure to patients and hospital personnel are considered. Some quantitative aspects of radiation damage in mammals relevant to the clinical use of radioiodine are reviewed. Emphasis is placed on applications of iodine-131 in diagnosis and therapy of hyperthyroidism and hypothyroidism; in the treatmeat of thyroid carcinoma; and in thyroid ablation for cardiac disease. 54 references. (C.H.)

  9. Guidelines for radioiodinated MIBG scintigraphy in children.

    PubMed

    Olivier, Pierre; Colarinha, Paula; Fettich, Jure; Fischer, Sibylle; Frökier, Jörgen; Giammarile, Francesco; Gordon, Isky; Hahn, Klaus; Kabasakal, Levent; Mann, Mike; Mitjavila, Mercedes; Piepsz, Amy; Porn, Ute; Sixt, Rune; van Velzen, Jeannette

    2003-05-01

    These guidelines on the use of radioiodinated (99m)Tc-MIBG scintigraphy in children, which summarise the views of the Paediatric Committee of the European Association of Nuclear Medicine, provide a framework which may prove helpful to nuclear medicine teams in daily practice. They have been influenced by the conclusions of the "Consensus Guidelines for MIBG Scintigraphy" (Paris, November 6, 1997) of the European Neuroblastoma Group and by those of the Oncological Committee of the French Society of Nuclear Medicine. The guidelines should be taken in the context of "good practice" and any local/national rules which apply to nuclear medicine examinations.

  10. Current practice of radioiodine treatment in the management of differentiated thyroid cancer in Germany.

    PubMed

    Hoelzer, S; Steiner, D; Bauer, R; Reiners, C; Farahati, J; Hundahl, S A; Dudeck, J

    2000-10-01

    This prospective, observational study of a cohort of thyroid cancer patients in Germany focusses on the "real-world" practice in the management of thyroid cancer patients. This report includes data from 2376 patients with primary differentiated thyroid carcinoma first diagnosed in the year 1996. The study reveals considerable differences in actual practice concerning surgery and radioiodine treatment. The results indicate that consensus is lacking with respect to the multimodality treatment approach for differentiated thyroid carcinoma. Our analysis represents the most current and comprehensive national assessment of presenting patient characteristics, diagnostic tests, treatment and complications for thyroid cancer.

  11. Seasonal variability of iodine and selenium in surface and groundwater as a factor that may contribute to iodine isotope balance in the thyroid gland and its irradiation in case of radioiodine contamination during accidents at the NPP

    NASA Astrophysics Data System (ADS)

    Korobova, Elena; Kolmykova, Lyudmila; Ryzhenko, Boris; Berezkin, Viktor; Saraeva, Anastasia

    2016-04-01

    Radioiodine release to the environment during the accident at the Chernobyl NPP led to the increased risk of the thyroid cancer cases within the contaminated areas, the effect being aggravated in conditions of stable iodine and selenium deficiency in local food chains. Although the drinking water iodine is usually believed to contribute not more than 10% to local diet, our estimations accounting of water content in other products and several regional studies (e.g. India and Australia) proved its portion to be at least twice as much. As radioiodine isotopes are short-lived, their absorption depends greatly on stable iodine and selenium sufficiency in thyroid gland in the first few days of contamination and seasonal variation of stable iodine and selenium in local sources of drinking water may be significant as modifying the resulting thyroid irradiation in different seasons of the year. The main goal of the study was to evaluate seasonal variation of levels of iodine and selenium in natural waters of the Bryansk region as a possible factor affecting the radioiodine intake by thyroid gland of animals and humans in case of radioiodine contamination during the accident. Seasonal I and Se concentration was measured in the years of 2014 and 2015 at 14 test points characterizing surface (river and lake) and drinking groundwater. Obtained data proved considerable seasonal variation of I and Se concentration in natural waters (3,7-8,1 μg/l and 0,04-0,4 μg/l respectively) related to physico-chemical water parameters, such as pH, Eh and fluctuations in concentration of dissolved organic matter. The widest I and Se seasonal variability was observed in surface and well waters, maximum I level being found in autumn at the end of vegetation period characterized by active I leaching from the decomposed organic residues by long lasting precipitations. The content of selenium in the surface waters during summer-autumn (0,06-0,3 μg/l) was higher than in spring (0,04-0,05 μg/l). In drinking water from centralized supply pipeline low concentration of both elements was also registered in spring (3,7-4,3 μg/l (I) and 0,04-0,08 μg/l (Se)). Accounting of the fact that both the Chernobyl and Fukushima accidents took place in spring, we hypothesis that low iodine intake with water may have contributed to the risk of higher radioiodine intake by thyroid gland in the period of the accident. The work was supported the Russian Foundation for Basic Research (grant 13-05-00823).

  12. The North American Carbon Program Multi-scale Synthesis and Terrestrial Model Intercomparison Project – Part 2: Environmental driver data

    DOE PAGES

    Wei, Yaxing; Liu, Shishi; Huntzinger, Deborah N.; ...

    2014-12-05

    Ecosystems are important and dynamic components of the global carbon cycle, and terrestrial biospheric models (TBMs) are crucial tools in further understanding of how terrestrial carbon is stored and exchanged with the atmosphere across a variety of spatial and temporal scales. Improving TBM skills, and quantifying and reducing their estimation uncertainties, pose significant challenges. The Multi-scale Synthesis and Terrestrial Model Intercomparison Project (MsTMIP) is a formal multi-scale and multi-model intercomparison effort set up to tackle these challenges. The MsTMIP protocol prescribes standardized environmental driver data that are shared among model teams to facilitate model model and model observation comparisons. Inmore » this article, we describe the global and North American environmental driver data sets prepared for the MsTMIP activity to both support their use in MsTMIP and make these data, along with the processes used in selecting/processing these data, accessible to a broader audience. Based on project needs and lessons learned from past model intercomparison activities, we compiled climate, atmospheric CO 2 concentrations, nitrogen deposition, land use and land cover change (LULCC), C3 / C4 grasses fractions, major crops, phenology and soil data into a standard format for global (0.5⁰ x 0.5⁰ resolution) and regional (North American: 0.25⁰ x 0.25⁰ resolution) simulations. In order to meet the needs of MsTMIP, improvements were made to several of the original environmental data sets, by improving the quality, and/or changing their spatial and temporal coverage, and resolution. The resulting standardized model driver data sets are being used by over 20 different models participating in MsTMIP. Lastly, the data are archived at the Oak Ridge National Laboratory Distributed Active Archive Center (ORNL DAAC, http://daac.ornl.gov) to provide long-term data management and distribution.« less

  13. NRC TLD Direct Radiation Monitoring Network. Volume 15, No. 4: Quarterly progress report, October--December 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Struckmeyer, R.

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1995. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program.

  14. Pliocene Model Intercomparison Project (PlioMIP): Experimental Design and Boundary Conditions (Experiment 2)

    NASA Technical Reports Server (NTRS)

    Haywood, A. M.; Dowsett, H. J.; Robinson, M. M.; Stoll, D. K.; Dolan, A. M.; Lunt, D. J.; Otto-Bliesner, B.; Chandler, M. A.

    2011-01-01

    The Palaeoclimate Modelling Intercomparison Project has expanded to include a model intercomparison for the mid-Pliocene warm period (3.29 to 2.97 million yr ago). This project is referred to as PlioMIP (the Pliocene Model Intercomparison Project). Two experiments have been agreed upon and together compose the initial phase of PlioMIP. The first (Experiment 1) is being performed with atmosphere only climate models. The second (Experiment 2) utilizes fully coupled ocean-atmosphere climate models. Following on from the publication of the experimental design and boundary conditions for Experiment 1 in Geoscientific Model Development, this paper provides the necessary description of differences and/or additions to the experimental design for Experiment 2.

  15. Pliocene Model Intercomparison Project (PlioMIP): experimental design and boundary conditions (Experiment 2)

    USGS Publications Warehouse

    Haywood, A.M.; Dowsett, H.J.; Robinson, M.M.; Stoll, D.K.; Dolan, A.M.; Lunt, D.J.; Otto-Bliesner, B.; Chandler, M.A.

    2011-01-01

    The Palaeoclimate Modelling Intercomparison Project has expanded to include a model intercomparison for the mid-Pliocene warm period (3.29 to 2.97 million yr ago). This project is referred to as PlioMIP (the Pliocene Model Intercomparison Project). Two experiments have been agreed upon and together compose the initial phase of PlioMIP. The first (Experiment 1) is being performed with atmosphere-only climate models. The second (Experiment 2) utilises fully coupled ocean-atmosphere climate models. Following on from the publication of the experimental design and boundary conditions for Experiment 1 in Geoscientific Model Development, this paper provides the necessary description of differences and/or additions to the experimental design for Experiment 2.

  16. Manufacture and calibration of optical supersmooth roughness artifacts for intercomparisons

    NASA Astrophysics Data System (ADS)

    Ringel, Gabriele A.; Kratz, Frank; Schmitt, Dirk-Roger; Mangelsdorf, Juergen; Creuzet, Francois; Garratt, John D.

    1995-09-01

    Intercomparison roughness measurements have been carried out on supersmooth artifacts fabricated from BK7, fused silica, and Zerodur. The surface parameters were determined using the optical heterodyne profiler Z5500 (Zygo), a special prototype of the mechanical profiler Nanostep (Rank Taylor Hobson), and an Atomic Force Microscope (Park Scientific Instruments) with an improved acquisition technique. The intercomparison was performed after the range of collected spatial wavelengths for each instrument was adjusted using digital filtering techniques. It is demonstrated for different roughness ranges that the applied superpolishing techniques yield supersmooth artifacts which can be used for more intercomparisons. More than 100 samples were investigated. Criteria were developed to select artifacts from the sample stock.

  17. Intercomparison of Radiation Codes in Climate Models (ICRCCM) Infrared (Clear-Sky) Line-by Line Radiative Fluxes (DB1002)

    DOE Data Explorer

    Arking, A.; Ridgeway, B.; Clough, T.; Iacono, M.; Fomin, B.; Trotsenko, A.; Freidenreich, S.; Schwarzkopf, D.

    1994-01-01

    The intercomparison of Radiation Codes in Climate Models (ICRCCM) study was launched under the auspices of the World Meteorological Organization and with the support of the U.S. Department of Energy to document differences in results obtained with various radiation codes and radiation parameterizations in general circulation models (GCMs). ICRCCM produced benchmark, longwave, line-by-line (LBL) fluxes that may be compared against each other and against models of lower spectral resolution. During ICRCCM, infrared fluxes and cooling rates for several standard model atmospheres with varying concentrations of water vapor, carbon dioxide, and ozone were calculated with LBL methods at resolutions of 0.01 cm-1 or higher. For comparison with other models, values were summed for the IR spectrum and given at intervals of 5 or 10 cm-1. This archive contains fluxes for ICRCCM-prescribed clear-sky cases. Radiative flux and cooling-rate profiles are given for specified atmospheric profiles for temperature, water vapor, and ozone-mixing ratios. The archive contains 328 files, including spectral summaries, formatted data files, and a variety of programs (i.e., C-shell scripts, FORTRAN codes, and IDL programs) to read, reformat, and display data. Collectively, these files require approximately 59 MB of disk space.

  18. Introduction The Role of the Agricultural Model Intercomparison and Improvement Project

    NASA Technical Reports Server (NTRS)

    Rosenzweig, Cynthia; Hillel, Daniel

    2015-01-01

    Climate impacts on agriculture are of increasing concern in both the scientific and policy communities because of the need to ensure food security for a growing population. A special challenge is posed by the changes in the frequency and intensity of heat-waves, droughts, and episodic rainstorms already underway in many parts of the world. Changes in production are directly linked to such variations in temperature and precipitation during the growing season, and often to offseason changes in weather affecting soil-water storage and availability to crops. This is not an isolated problem but one of both global and regional importance, because of impacts on the livelihoods of smallholder farmers as well as consequences for the world food trade system. This two-part set the Agricultural Model Intercomparison and Improvement Project (AgMIP): Integrated Crop and Economic Assessments is the first to be entirely devoted to AgMIP (www.agmip.org). AgMIP is a major international research program focused on climate change and agriculture. The goal of the two parts is to advance the field by providing detailed information on new simulation techniques and assessments being conducted by this program. It presents information about new methods of global and regional integrated assessment, results from agricultural regions, and adaptation strategies for maintaining food security under changing climate conditions.

  19. Chinese Data of Efficacy of Low- and High-Dose Iodine-131 for the Ablation of Thyroid Remnant.

    PubMed

    Ma, Chao; Feng, Fang; Wang, Shaoyan; Fu, Hongliang; Wu, Shuqi; Ye, Zhiyi; Chen, Suyun; Wang, Hui

    2017-06-01

    Chinese data on the efficacy of low- and high-dose radioiodine for thyroid remnant are still absent. The aim of the study was to investigate whether a low dose of radioiodine is as effective as a high dose for remnant ablation in Chinese patients. Patients presenting for radioiodine ablation in the authors' department were included. Inclusion criteria were aged ≥16 years, total or near-total thyroidectomy, tumor-node-metastasis (TNM) stage of pT1-3, any N stage, and M0. All patients were randomly allocated to either the high-dose group of 3700 MBq or the low-dose group of 1850 MBq for remnant ablation. The response to treatment was defined as successful or unsuccessful after a six- to nine-month interval. Ablation was considered to be successful if patients fulfilled the following criteria: no tracer uptake in the thyroid bed on diagnosis whole-body scanning and a negative level of serum thyroglobulin. There were 327 patients enrolled between January 2013 and December 2014. More than 95% had papillary thyroid cancer. Data could be analyzed for 278 cases (M age  = 44 years; 71.6% women), 155 in the low-dose group and 123 in the high-dose group. The rate of initial successful ablation was 84.2% in all patients, 82.6% in the low-dose group, and 86.2% in the high-dose group. There was no difference between the two groups (p = 0.509). In Chinese patients with differentiated thyroid carcinoma, the low dose of 1850 MBq radioiodine activity is as effective as a high dose of 3700 MBq for thyroid remnant ablation.

  20. Epidemiology, management and outcomes of Graves' disease-real life data.

    PubMed

    Hussain, Y S; Hookham, J C; Allahabadia, A; Balasubramanian, S P

    2017-06-01

    Treatment options in Graves' disease are clearly defined, but management practices and the perceptions of success are varied. The outcomes of treatment in large consecutive cohorts of Graves' disease have not been well characterised. The study describes the epidemiology, management strategies and medium term outcomes following anti-thyroid drug treatment, radio-iodine ablation and surgery in Graves' disease. All patients (n = 659) who received treatment for a new diagnosis of Graves' disease in secondary care over a 5 year period were included with a median (interquartile range) follow-up of 42.9 (29-57.5) months. The age adjusted incidence of adult onset Graves' disease in Sheffield, UK was 24.8 per 100,000 per year. Excluding 35 patients lost to follow-up, 93.1% (n = 581) were controlled on anti-thyroid drug treatment. Of these, 73.6% went into remission following withdrawal of anti-thyroid drugs; 5.2% were still undergoing initial therapy; 13.3% lost control whilst on anti-thyroid drugs; and 7.9% went on to have either surgery or radio-iodine ablation whilst controlled on anti-thyroid drugs. Of the 428 patients who achieved remission, 36.7% relapsed. Of 144 patients who had radio-iodine ablation treatment, 5.6% relapsed and needed further treatment. Of 119 patients having surgery, 5.2% had long-term hypoparathyroidism and none had documented long-term recurrent laryngeal nerve palsy. In the follow-up, 39.9% of patients underwent surgery or radio-iodine ablation with little morbidity. Up to two-thirds of patients who achieved remission did not relapse. Data on effectiveness and risks of treatments for Graves' disease presented in this study will help clinicians and patients in decision making.

  1. Accuracy and optimal timing of activity measurements in estimating the absorbed dose of radioiodine in the treatment of Graves' disease

    NASA Astrophysics Data System (ADS)

    Merrill, S.; Horowitz, J.; Traino, A. C.; Chipkin, S. R.; Hollot, C. V.; Chait, Y.

    2011-02-01

    Calculation of the therapeutic activity of radioiodine 131I for individualized dosimetry in the treatment of Graves' disease requires an accurate estimate of the thyroid absorbed radiation dose based on a tracer activity administration of 131I. Common approaches (Marinelli-Quimby formula, MIRD algorithm) use, respectively, the effective half-life of radioiodine in the thyroid and the time-integrated activity. Many physicians perform one, two, or at most three tracer dose activity measurements at various times and calculate the required therapeutic activity by ad hoc methods. In this paper, we study the accuracy of estimates of four 'target variables': time-integrated activity coefficient, time of maximum activity, maximum activity, and effective half-life in the gland. Clinical data from 41 patients who underwent 131I therapy for Graves' disease at the University Hospital in Pisa, Italy, are used for analysis. The radioiodine kinetics are described using a nonlinear mixed-effects model. The distributions of the target variables in the patient population are characterized. Using minimum root mean squared error as the criterion, optimal 1-, 2-, and 3-point sampling schedules are determined for estimation of the target variables, and probabilistic bounds are given for the errors under the optimal times. An algorithm is developed for computing the optimal 1-, 2-, and 3-point sampling schedules for the target variables. This algorithm is implemented in a freely available software tool. Taking into consideration 131I effective half-life in the thyroid and measurement noise, the optimal 1-point time for time-integrated activity coefficient is a measurement 1 week following the tracer dose. Additional measurements give only a slight improvement in accuracy.

  2. Juvenile hypothyroidism among two populations exposed to radioiodine.

    PubMed Central

    Goldsmith, J R; Grossman, C M; Morton, W E; Nussbaum, R H; Kordysh, E A; Quastel, M R; Sobel, R B; Nussbaum, F D

    1999-01-01

    We found an epidemic of juvenile hypothyroidism among a population of self-defined "downwinders" living near the Hanford nuclear facility located in southeast Washington State. The episode followed massive releases of 131I. Self-reported data on 60 cases of juvenile hypothyroidism (<20 years of age) among a group of 801 Hanford downwinders are presented, as well as data concerning the thyroid status of approximately 160,000 children exposed to radioiodine before 10 years of age as a result of the 26 April 1986 Chernobyl explosion in the former Soviet Union. These children were residents of five regions near Chernobyl. They were examined by standardized screening protocols over a period of 5 years from 1991 to 1996. They are a well-defined group of 10 samples. Fifty-six cases of hypothyroidism were found among boys and 92 among girls. Body burdens of 137Cs have been correlated with hypothyroidism prevalence rates. On the other hand, the group of juvenile (<20 years of age) Hanford downwinders is not a representative sample. Most of the 77 cases of juvenile hypothyroidism in the Hanford group were diagnosed from 1945 to 1970. However, the ratio of reported cases to the county population under 20 years of age is roughly correlated with officially estimated mean levels of cumulative thyroid 131I uptake in these counties, providing evidence that juvenile hypothyroidism was associated with radioiodine exposures. Because even subtle hypothyroidism may be of clinical significance in childhood and can be treated, it may be useful to screen for the condition in populations exposed to radioiodine fallout. Although radiation exposure is associated with hypothyroidism, its excess among fallout-exposed children has not been previously quantified. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 PMID:10090710

  3. Dynamic PET and SPECT imaging with radioiodinated, amyloid-reactive peptide p5 in mice: A positive role for peptide dehalogenation

    PubMed Central

    Martin, Emily B.; Kennel, Stephen J.; Richey, Tina; Wooliver, Craig; Osborne, Dustin; Williams, Angela; Stuckey, Alan; Wall, Jonathan S.

    2014-01-01

    Dynamic molecular imaging provides bio-kinetic data that is used to characterize novel radiolabeled tracers for the detection of disease. Amyloidosis is a rare protein misfolding disease that can affect many organs. It is characterized by extracellular deposits composed principally of fibrillar proteins and hypersulfated proteoglycans. We have previously described a peptide, p5, which binds preferentially to amyloid deposits in a murine model of reactive (AA) amyloidosis. We have determined the whole body distribution of amyloid by molecular imaging techniques using radioiodinated p5. The loss of radioiodide from imaging probes due to enzymatic reaction has plagued the use of radioiodinated peptides and antibodies. Therefore, we studied iodine-124-labeled p5 by using dynamic PET imaging of both amyloid-laden and healthy mice to assess the rates of amyloid binding, the relevance of dehalogenation and the fate of the radiolabeled peptide. Rates of blood pool clearance, tissue accumulation and dehalogenation of the peptide were estimated from the images. Comparisons of these properties between the amyloid-laden and healthy mice provided kinetic profiles whose differences may prove to be indicative of the disease state. Additionally, we performed longitudinal SPECT/CT imaging with iodine-125-labeled p5 up to 72 hours post injection to determine the stability of the radioiodinated peptide when bound to the extracellular amyloid. Our data show that amyloid-associated peptide, in contrast to the unbound peptide, is resistant to dehalogenation resulting in enhanced amyloid-specific imaging. These data further support the utility of this peptide for detecting amyloidosis and monitoring potential therapeutic strategies in patients. PMID:25102446

  4. Dynamic PET and SPECT imaging with radioiodinated, amyloid-reactive peptide p5 in mice: a positive role for peptide dehalogenation.

    PubMed

    Martin, Emily B; Kennel, Stephen J; Richey, Tina; Wooliver, Craig; Osborne, Dustin; Williams, Angela; Stuckey, Alan; Wall, Jonathan S

    2014-10-01

    Dynamic molecular imaging provides bio-kinetic data that is used to characterize novel radiolabeled tracers for the detection of disease. Amyloidosis is a rare protein misfolding disease that can affect many organs. It is characterized by extracellular deposits composed principally of fibrillar proteins and hypersulfated proteoglycans. We have previously described a peptide, p5, which binds preferentially to amyloid deposits in a murine model of reactive (AA) amyloidosis. We have determined the whole body distribution of amyloid by molecular imaging techniques using radioiodinated p5. The loss of radioiodide from imaging probes due to enzymatic reaction has plagued the use of radioiodinated peptides and antibodies. Therefore, we studied iodine-124-labeled p5 by using dynamic PET imaging of both amyloid-laden and healthy mice to assess the rates of amyloid binding, the relevance of dehalogenation and the fate of the radiolabeled peptide. Rates of blood pool clearance, tissue accumulation and dehalogenation of the peptide were estimated from the images. Comparisons of these properties between the amyloid-laden and healthy mice provided kinetic profiles whose differences may prove to be indicative of the disease state. Additionally, we performed longitudinal SPECT/CT imaging with iodine-125-labeled p5 up to 72h post injection to determine the stability of the radioiodinated peptide when bound to the extracellular amyloid. Our data show that amyloid-associated peptide, in contrast to the unbound peptide, is resistant to dehalogenation resulting in enhanced amyloid-specific imaging. These data further support the utility of this peptide for detecting amyloidosis and monitoring potential therapeutic strategies in patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Thyroid Cysts in Cats: A Retrospective Study of 40 Cases.

    PubMed

    Miller, M L; Peterson, M E; Randolph, J F; Broome, M R; Norsworthy, G D; Rishniw, M

    2017-05-01

    Thyroid cysts are rare in cats and poorly documented. To report distinguishing clinical features and treatment responses of cats with thyroid cysts. Forty client-owned cats. Retrospective review of medical records for cats with thyroid cysts confirmed by scintigraphy, ultrasound, magnetic resonance imaging, or necropsy at 4 referral centers between 2005 and 2016. Signalment, clinical findings, diagnostic testing, treatment, and outcome were recorded. Cats ranged in age from 8 to 20 years with no apparent breed or sex predilection. 37 of 40 (93%) cats were hyperthyroid (duration, 1-96 months). Clinical findings included palpable neck mass (40/40, 100%), weight loss (15/40, 38%), dysphagia (8/40, 20%), decreased appetite (5/40, 13%), and dyspnea (4/40, 10%). Cysts were classified as small (≤8 cm 3 ) in 16 (40%) and large (>8 cm 3 ) in 24 (60%) cats. Of 25 cats treated with radioiodine, hyperthyroidism resolved in 23 (92%), whereas thyroid cysts resolved in 12 (50%). Radioiodine treatment resolved small cysts in 8 of 13 (62%) cats and large cysts in 4 of 11 (36%) cats. Eight cats, including 2 euthyroid cats, underwent thyroid-cystectomy; 3 with bilateral thyroid involvement were euthanized postoperatively for hypocalcemia. Excised cystic thyroid masses were identified as cystadenoma (4) and carcinoma (4). Thyroid cysts are encountered in hyperthyroid and euthyroid cats with benign and malignant thyroid tumors. Radioiodine treatment alone inconsistently resolved thyroid cysts. Thyroid-cystectomy could be considered in cats with unilateral thyroid disease or when symptomatic cysts persist despite successful radioiodine treatment of hyperthyroidism. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  6. Impact of the Amount of Liquid Intake on the Dose Rate of Patients Treated with Radioiodine.

    PubMed

    Haghighatafshar, Mahdi; Banani, Aida; Zeinali-Rafsanjani, Banafsheh; Etemadi, Zahra; Ghaedian, Tahereh

    2018-01-01

    Despite therapeutic effects of radioiodine in patients with differentiated thyroid cancer, there are some disadvantages due to harmful radiation to other tissues. According to the current guidelines, patients are recommended to drink lots of water and frequent voiding to reduce the amount of 131 I in the body. This study was designed to assess the impact of the amount of liquid intake on reduction of the measured dose rate of radioiodine-treated patients. A total of 42 patients with differentiated thyroid cancer without metastasis who had undergone total thyroidectomy and had been treated with radioiodine were selected. The patients were divided into two groups according to the amount of their fluid intake which was measured during the first 48 h after 131 I administration. In all patients, the dose rate was measured immediately and 48 h after iodine administration. Each group included 21 patients. Dose rate ratio (the ratio of the second dose rate to the first dose rate) and dose rate difference ratio (the ratio of the difference between the two measured dose rates to the first dose rate) were calculated for each patient. Despite the significant difference in the amount of the liquid drunk, no statistically significant difference was seen between the different groups in parameters of dose-rate ratio and dose-rate difference ratio. Higher fluid intake (>60 ml/h in our study) alone would not effectively reduce the patient's radiation dose rate at least not more than a well-hydrated state. It seems that other interfering factors in the thyroidectomized patients may also have some impacts on this physiologic process.

  7. (131)I treatment in Differentiated Thyroid Cancer and End-Stage Renal Disease.

    PubMed

    Ortega, A J M; Vázquez, R G; Cuenca, J I C; Brocca, M A M; Castilla, J; Martínez, J M M; González, E N

    2016-01-01

    Radioiodine (RAI) is a cornerstone in the treatment of Differentiated Thyroid Cancer (DTC). In patients on haemodialysis due to End-Stage Renal Disease (ESRD), it must be used cautiously, considering the renal clearance of this radionuclide. Also, the safety of the procedure and subsequent long-term outcome is still not well defined. In 2001, we described a dosimetric method and short-term results in three patients, with a good safety profile. We hypothesize that our method is safe in a long-term scenario without compromising the prognosis of both renal and thyroid disease. Descriptive-retrospective study. A systematic search was carried out using our clinical database from 2000 to 2014. DTC and radioiodine treatment while on haemodialysis. peritoneal dialysis. Final sample n=9 patients (n=5 males), age 48 years (median age 51 years males, 67 years female group); n=8 papillary thyroid cancer, n=1 follicular thyroid cancer; n=5 lymph node invasion; n=1 metastatic disease. Median RAI dose administered on haemodialysis 100mCi. 7.5 years after radioiodine treatment on haemodialysis, n=7 deemed free of thyroid disease, n=1 persistent non-localised disease. No complications related to the procedure or other target organs were registered. After 3.25 years, n=4 patients underwent successful renal transplantation; n=4 patients did not meet transplantation criteria due to other conditions unrelated to the thyroid disease or its treatment. One patient died due to ischemic cardiomyopathy (free of thyroid disease). Radioiodine treatment during haemodialysis is a long-term, safe procedure without worsening prognosis of either renal or thyroid disease. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  8. Treatment of hyperthyroidism with radioiodine targeted activity: A comparison between two dosimetric methods.

    PubMed

    Amato, Ernesto; Campennì, Alfredo; Leotta, Salvatore; Ruggeri, Rosaria M; Baldari, Sergio

    2016-06-01

    Radioiodine therapy is an effective and safe treatment of hyperthyroidism due to Graves' disease, toxic adenoma, toxic multinodular goiter. We compared the outcomes of a traditional calculation method based on an analytical fit of the uptake curve and subsequent dose calculation with the MIRD approach, and an alternative computation approach based on a formulation implemented in a public-access website, searching for the best timing of radioiodine uptake measurements in pre-therapeutic dosimetry. We report about sixty-nine hyperthyroid patients that were treated after performing a pre-therapeutic dosimetry calculated by fitting a six-point uptake curve (3-168h). In order to evaluate the results of the radioiodine treatment, patients were followed up to sixty-four months after treatment (mean 47.4±16.9). Patient dosimetry was then retrospectively recalculated with the two above-mentioned methods. Several time schedules for uptake measurements were considered, with different timings and total number of points. Early time schedules, sampling uptake up to 48h, do not allow to set-up an accurate treatment plan, while schedules including the measurement at one week give significantly better results. The analytical fit procedure applied to the three-point time schedule 3(6)-24-168h gave results significantly more accurate than the website approach exploiting either the same schedule, or the single measurement at 168h. Consequently, the best strategy among the ones considered is to sample the uptake at 3(6)-24-168h, and carry out an analytical fit of the curve, while extra measurements at 48 and 72h lead only marginal improvements in the accuracy of therapeutic activity determination. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Wind Profiling from a New Compact, Pulsed, 2-Micron, Coherent-Detection Doppler Lidar Transceiver during Wind Measurement Intercomparison

    NASA Technical Reports Server (NTRS)

    Singh, Upendra N.; Koch, Grady J.; Kavaya, Michael J.; Yu, Jirong; Beyon, Jeffrey Y.; Demoz, B.; Veneable, D.

    2009-01-01

    NASA Langley Research Center has a long history of developing 2-micron laser transmitter for wind sensing. With support from NASA Laser Risk Reduction Program (LRRP) and Instrument Incubator Program (IIP), NASA Langley Research Center has developed a state-of-the-art compact lidar transceiver for a pulsed coherent Doppler lidar system for wind measurement. This lidar system was recently deployed at Howard University facility in Beltsville, Maryland, along with other wind lidar systems. Coherent Doppler wind lidar ground-based wind measurements and comparisons with other lidars and other sensors will be presented.

  10. Invited Article: Radon and thoron intercomparison experiments for integrated monitors at NIRS, Japan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Janik, M., E-mail: mirek@fml.nirs.go.jp; Ishikawa, T.; Omori, Y.

    Inhalation of radon ({sup 222}Rn) and its short-lived decay products and of products of the thoron ({sup 220}Rn) series accounts for more than half of the effective dose from natural radiation sources. At this time, many countries have begun large-scale radon and thoron surveys and many different measurement methods and instruments are used in these studies. Consequently, it is necessary to improve and standardize technical methods of measurements and to verify quality assurance by intercomparisons between laboratories. Four international intercomparisons for passive integrating radon and thoron monitors were conducted at the NIRS (National Institute of Radiological Sciences, Japan). Radon exercisesmore » were carried out in the 24.4 m{sup 3} inner volume walk-in radon chamber that has systems to control radon concentration, temperature, and humidity. Moreover, the NIRS thoron chamber with a 150 dm{sup 3} inner volume was utilized to provide three thoron intercomparisons. At present, the NIRS is the only laboratory world-wide that has carried out periodic thoron intercomparison of passive monitors. Fifty laboratories from 26 countries participated in the radon intercomparison, using six types of detectors (charcoal, CR-39, LR 115, polycarbonate film, electret plate, and silicon photodiode). Eighteen laboratories from 12 countries participated in the thoron intercomparisons, using two etch-track types (CR-39 and polycarbonate) detectors. The tests were made under one to three different exposures to radon and thoron. The data presented in this paper indicated that the performance quality of laboratories for radon measurement has been gradually increasing. Results of thoron exercises showed that the quality for thoron measurements still needs further development and additional studies are needed to improve its measuring methods. The present paper provides a summary of all radon and thoron international intercomparisons done at NIRS from 2007 to date and it describes the present status on radon and thoron passive, one-time cycle monitors.« less

  11. Pliocene Model Intercomparison (PlioMIP) Phase 2: Scientific Objectives and Experimental Design

    NASA Technical Reports Server (NTRS)

    Haywood, A. M.; Dowsett, H. J.; Dolan, A. M.; Rowley, D.; Abe-Ouchi, A.; Otto-Bliesner, B.; Chandler, M. A.; Hunter, S. J.; Lunt, D. J.; Pound, M.; hide

    2015-01-01

    The Pliocene Model Intercomparison Project (PlioMIP) is a co-ordinated international climate modelling initiative to study and understand climate and environments of the Late Pliocene, and their potential relevance in the context of future climate change. PlioMIP operates under the umbrella of the Palaeoclimate Modelling Intercomparison Project (PMIP), which examines multiple intervals in Earth history, the consistency of model predictions in simulating these intervals and their ability to reproduce climate signals preserved in geological climate archives. This paper provides a thorough model intercomparison project description, and documents the experimental design in a detailed way. Specifically, this paper describes the experimental design and boundary conditions that will be utilized for the experiments in Phase 2 of PlioMIP.

  12. (131)I-Nimotuzumab - A potential radioimmunotherapeutic agent in treatment of tumors expressing EGFR.

    PubMed

    Kameswaran, Mythili; Samuel, Grace; Dev Sarma, Haladhar; Shinde, Swamirao N; Dash, Ashutosh; Venkatesh, Meera

    2015-08-01

    The anti-EGFR antibody Nimotuzumab was radioiodinated with I-131 by Chloramine T and Iodogen methods. The (131)I-Nimotuzumab was purified and characterized by HPLC. Purified (131)I-Nimotuzumab exhibited radiochemical purity of >95% and retained good in vitro stability upto 24h at room temperature by both the methods. Cell binding studies carried out in A431 cells expressing EGF receptors showed good immunoreactivity of the product upto 5 days post radioiodination. Biodistribution studies in normal Swiss mice showed fast clearance by both renal and gastrointestinal routes with minimal thyroid uptake. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. From prophylaxis to atomic cocktail: circulation of radioiodine.

    PubMed

    Santesmases, María Jesús

    2009-01-01

    This paper is a history of iodine. To trace the trajectory of this element, goiter is used as a guideline for the articulation of a historical account, as a representation of thyroid disorders and of the spaces of knowledge and practices related to iodine. Iodine's journey from goiter treatment and prophylaxis in the late interwar period took on a new course after WWII by including the element's radioactive isotopes. I intend to show how the introduction of radioiodine contributed to stabilize the epistemic role of iodine, in both its non-radioactive and radioactive form, in thyroid gland studies and in the treatment of its disorders.

  14. Lymphocyte function following radioiodine therapy in patients with thyroid carcinoma.

    PubMed

    Barsegian, V; Müller, S P; Horn, P A; Bockisch, A; Lindemann, M

    2011-01-01

    Since the nuclear disaster in Fukushima has raised great concern about the danger of radioactivity, we here addressed the question if the therapeutic use of iodine 131, the most frequently applied radionuclide, was harmful to immune function in patients. It was our aim to define for the first time in a clinical setting how radioiodine therapy alters anti-microbial immune responses. In 21 patients with thyroid carcinoma anti-microbial lymphocyte responses were assessed by lymphocyte transformation test and ELISpot - measuring lymphocyte proliferation and on a single cell level production of pro- and anti-inflammatory cytokines (interferon-γ and interleukin-10) - prior to therapy, at day 1 and day 7 post therapy. Proliferative lymphocyte responses and interferon-γ production after in vitro stimulation with microbial antigens were significantly (p < 0.05) increased at day 1 vs. pre therapy, and returned to pre therapy levels at day 7. On the contrary, at day 1 interleukin-10 production was significantly (p < 0.05) reduced. Thus, we observed a short-term increase in pro-inflammatory immune responses. However, T lymphocyte responses were in the range of healthy controls at all three time points. Thyroid carcinoma patients receiving radioiodine therapy do not display any sign of immunosuppression.

  15. Benefits of automated surface decontamination of a radioiodine ward.

    PubMed

    Westcott, Eliza; Broadhurst, Alicia; Crossley, Steven; Lee, Lloyd; Phan, Xuyen; Scharli, Rainer; Xu, Yan

    2012-02-01

    A floor-washing robot has been acquired to assist physicists with decontamination of radioiodine therapy ward rooms after discharge of the patient at Sir Charles Gairdner Hospital. The effectiveness of the robot in decontaminating the ward has been evaluated. A controlled experiment was performed by deliberately contaminating a polyvinyl chloride flooring offcut with 131I followed by automated decontamination with the robot. The extent of fixed and removable contamination was assessed before and after decontamination by two methods: (1) direct Geiger-Mueller counting and (2) beta-counting wipe tests. Surface contamination was also assessed in situ on the ward by Geiger-Mueller counting and wipe testing. Contamination maps confirmed that contamination was removed rather than spread around by the robot. Wipe testing revealed that the robot was successful in clearing approximately 60-80% of removable contamination. The robotic floor-washing device was considered suitable to provide effective automated decontamination of the radioiodine ward. In addition, the robot affords other benefits: the time spent by the physicists decontaminating the room is greatly reduced offering financial and occupational safety and health benefits. The robot has also found utility in other decontamination applications in the healthcare environment.

  16. Unexpected effect of furosemide on radioiodine urinary excretion in patients with differentiated thyroid carcinomas treated with iodine 131.

    PubMed

    Matovic, Milovan D; Jankovic, Slobodan M; Jeremic, Marija; Tasic, Zoran; Vlajkovic, Marina

    2009-08-01

    In patients receiving (131)I for therapeutic purposes, diuretics are frequently used in an attempt to accelerate elimination of unbound radioiodine, reduce its adverse effects, and shorten the hospital stay. The aims of our study were to investigate the influence of furosemide therapy on urinary excretion of (131)I in patients with differentiated thyroid cancer (DTC), referred to radioiodine ablation after thyroidectomy, and to investigate whether diuretics are useful in daily practice in patients with DTC. Forty-three patients with DTC who had normal renal function and low (131)I uptake in cervical region (3.55 +/- 3.45%) were included in this study. The furosemide (20 mg) and potassium chloride (250 mg) were given orally to 23 patients 3 hours after the (131)I administration, and then q8h for 3 days. Twenty patients did not receive either furosemide or potassium chloride. After (131)I administration, the patients collected their urine for 3 days, and radioactivity of urine sample from each micturition was expressed as percentage of the administered dose. Radioactivity of blood samples was measured after 72 hours, and the values were corrected for decay of (131)I and expressed in relation to the administered dose. Initial whole-body measurement (immediately after (131)I administration) and the whole-body measurement after 72 hours were recorded for all patients. The 72-hour whole-body measurement was corrected for decay of (131)I, and expressed as a percentage of the initial whole-body measurement. Urinary excretion of (131)I was significantly lower in the patients who were taking furosemide and potassium chloride compared with the control group. The whole-body measurements after 72 hours (13.22 +/- 6.55% vs. 8.24 +/- 3.39% of the initial; p < 0.01, respectively) and the blood radioactivity (34.66 +/- 24.84 vs. 11.64 +/- 8.32 cpm/mL per 1 MBq of administered (131)I, p < 0.01) were found to be unexpectedly higher in the patients who were taking furosemide and potassium chloride compared with the control group. Our results demonstrated that furosemide given as an adjuvant medication in patients with DTC causes a significant decrease in urinary excretion of radioiodine and its higher blood concentration. Therefore, furosemide should not be recommended as an adjuvant therapy to radioiodine ablation in patients with DTC previously iodine depleted by low-iodine diet.

  17. Comparison of mortality in hyperthyroidism during periods of treatment with thionamides and after radioiodine.

    PubMed

    Boelaert, Kristien; Maisonneuve, Patrick; Torlinska, Barbara; Franklyn, Jayne A

    2013-05-01

    Hyperthyroidism is common, but opinions regarding optimal therapy with antithyroid drugs or radioiodine (131-I) differ. There are no randomized trials comparing these options in terms of mortality. The aim of the study was to determine whether mortality associated with hyperthyroidism varies with treatment administered or other factors. We conducted a prospective observational population-based study of 1036 subjects aged ≥ 40 years presenting to a single specialist clinic from 1989-2003 with a first episode of hyperthyroidism who were followed until June 2012. Antithyroid drugs or radioiodine (131-I) were administered. We compared causes of death with age-, sex-, and period-specific mortality in England and Wales and used within-cohort analysis of influence of treatment modality, outcome, disease etiology, severity and control, and comorbidities. In 12 868 person-years of follow-up, 334 died vs 290.6 expected (standardized mortality ratio [SMR], 1.15 [95% confidence interval (CI),1.03-1.28]; P = .01). Increased all-cause mortality largely reflected increased circulatory deaths (SMR, 1.20 [95% CI, 1.01-1.43]; P = .04). All-cause mortality was increased for the person-years accumulated during thionamide treatment (SMR, 1.30 [95% CI, 1.05-1.61]; P = .02) and after 131-I not associated with hypothyroidism (SMR, 1.24 [95% CI, 1.04-1.46]; P = .01) but not during T₄ replacement for 131-I-induced hypothyroidism (SMR, 0.98 [95% CI, 0.82-1.18]; P = .85). Within-cohort analysis comparing mortality during thionamide treatment showed a similar hazard ratio (HR) for all-cause mortality when 131-I did not result in hypothyroidism (HR, 0.95 [95% CI, 0.70-1.29]), but reduced mortality with 131-I-induced hypothyroidism (HR, 0.70 [95% CI, 0.51-0.96]). Reduced mortality associated with hypothyroidism was seen only in those without significant comorbidities and not in those with other serious diseases. Atrial fibrillation at presentation (P = .02) and an increment of 10 pmol/L in serial free T₄ concentration during follow-up (P = .009) were independently associated with mortality. Among hyperthyroid subjects aged 40 years or older, mortality was increased during periods of thionamide treatment and after radioiodine not resulting in hypothyroidism, but not during follow-up after radioiodine-induced hypothyroidism. Independent associations of mortality with atrial fibrillation and incomplete biochemical control during treatment indicate potential causative links with poor outcome.

  18. Design and results of the ice sheet model initialisation experiments initMIP-Greenland: an ISMIP6 intercomparison

    NASA Astrophysics Data System (ADS)

    Goelzer, Heiko; Nowicki, Sophie; Edwards, Tamsin; Beckley, Matthew; Abe-Ouchi, Ayako; Aschwanden, Andy; Calov, Reinhard; Gagliardini, Olivier; Gillet-Chaulet, Fabien; Golledge, Nicholas R.; Gregory, Jonathan; Greve, Ralf; Humbert, Angelika; Huybrechts, Philippe; Kennedy, Joseph H.; Larour, Eric; Lipscomb, William H.; Le clec'h, Sébastien; Lee, Victoria; Morlighem, Mathieu; Pattyn, Frank; Payne, Antony J.; Rodehacke, Christian; Rückamp, Martin; Saito, Fuyuki; Schlegel, Nicole; Seroussi, Helene; Shepherd, Andrew; Sun, Sainan; van de Wal, Roderik; Ziemen, Florian A.

    2018-04-01

    Earlier large-scale Greenland ice sheet sea-level projections (e.g. those run during the ice2sea and SeaRISE initiatives) have shown that ice sheet initial conditions have a large effect on the projections and give rise to important uncertainties. The goal of this initMIP-Greenland intercomparison exercise is to compare, evaluate, and improve the initialisation techniques used in the ice sheet modelling community and to estimate the associated uncertainties in modelled mass changes. initMIP-Greenland is the first in a series of ice sheet model intercomparison activities within ISMIP6 (the Ice Sheet Model Intercomparison Project for CMIP6), which is the primary activity within the Coupled Model Intercomparison Project Phase 6 (CMIP6) focusing on the ice sheets. Two experiments for the large-scale Greenland ice sheet have been designed to allow intercomparison between participating models of (1) the initial present-day state of the ice sheet and (2) the response in two idealised forward experiments. The forward experiments serve to evaluate the initialisation in terms of model drift (forward run without additional forcing) and in response to a large perturbation (prescribed surface mass balance anomaly); they should not be interpreted as sea-level projections. We present and discuss results that highlight the diversity of data sets, boundary conditions, and initialisation techniques used in the community to generate initial states of the Greenland ice sheet. We find good agreement across the ensemble for the dynamic response to surface mass balance changes in areas where the simulated ice sheets overlap but differences arising from the initial size of the ice sheet. The model drift in the control experiment is reduced for models that participated in earlier intercomparison exercises.

  19. Design and results of the ice sheet model initialisation experiments initMIP-Greenland: an ISMIP6 intercomparison

    DOE PAGES

    Goelzer, Heiko; Nowicki, Sophie; Edwards, Tamsin; ...

    2018-04-19

    Earlier large-scale Greenland ice sheet sea-level projections (e.g. those run during the ice2sea and SeaRISE initiatives) have shown that ice sheet initial conditions have a large effect on the projections and give rise to important uncertainties. Here, the goal of this initMIP-Greenland intercomparison exercise is to compare, evaluate, and improve the initialisation techniques used in the ice sheet modelling community and to estimate the associated uncertainties in modelled mass changes. initMIP-Greenland is the first in a series of ice sheet model intercomparison activities within ISMIP6 (the Ice Sheet Model Intercomparison Project for CMIP6), which is the primary activity within themore » Coupled Model Intercomparison Project Phase 6 (CMIP6) focusing on the ice sheets. Two experiments for the large-scale Greenland ice sheet have been designed to allow intercomparison between participating models of (1) the initial present-day state of the ice sheet and (2) the response in two idealised forward experiments. The forward experiments serve to evaluate the initialisation in terms of model drift (forward run without additional forcing) and in response to a large perturbation (prescribed surface mass balance anomaly); they should not be interpreted as sea-level projections. We present and discuss results that highlight the diversity of data sets, boundary conditions, and initialisation techniques used in the community to generate initial states of the Greenland ice sheet. We find good agreement across the ensemble for the dynamic response to surface mass balance changes in areas where the simulated ice sheets overlap but differences arising from the initial size of the ice sheet. The model drift in the control experiment is reduced for models that participated in earlier intercomparison exercises.« less

  20. Design and results of the ice sheet model initialisation experiments initMIP-Greenland: an ISMIP6 intercomparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goelzer, Heiko; Nowicki, Sophie; Edwards, Tamsin

    Earlier large-scale Greenland ice sheet sea-level projections (e.g. those run during the ice2sea and SeaRISE initiatives) have shown that ice sheet initial conditions have a large effect on the projections and give rise to important uncertainties. Here, the goal of this initMIP-Greenland intercomparison exercise is to compare, evaluate, and improve the initialisation techniques used in the ice sheet modelling community and to estimate the associated uncertainties in modelled mass changes. initMIP-Greenland is the first in a series of ice sheet model intercomparison activities within ISMIP6 (the Ice Sheet Model Intercomparison Project for CMIP6), which is the primary activity within themore » Coupled Model Intercomparison Project Phase 6 (CMIP6) focusing on the ice sheets. Two experiments for the large-scale Greenland ice sheet have been designed to allow intercomparison between participating models of (1) the initial present-day state of the ice sheet and (2) the response in two idealised forward experiments. The forward experiments serve to evaluate the initialisation in terms of model drift (forward run without additional forcing) and in response to a large perturbation (prescribed surface mass balance anomaly); they should not be interpreted as sea-level projections. We present and discuss results that highlight the diversity of data sets, boundary conditions, and initialisation techniques used in the community to generate initial states of the Greenland ice sheet. We find good agreement across the ensemble for the dynamic response to surface mass balance changes in areas where the simulated ice sheets overlap but differences arising from the initial size of the ice sheet. The model drift in the control experiment is reduced for models that participated in earlier intercomparison exercises.« less

  1. Intercomparison of three microwave/infrared high resolution line-by-line radiative transfer codes

    NASA Astrophysics Data System (ADS)

    Schreier, F.; Garcia, S. Gimeno; Milz, M.; Kottayil, A.; Höpfner, M.; von Clarmann, T.; Stiller, G.

    2013-05-01

    An intercomparison of three line-by-line (lbl) codes developed independently for atmospheric sounding - ARTS, GARLIC, and KOPRA - has been performed for a thermal infrared nadir sounding application assuming a HIRS-like (High resolution Infrared Radiation Sounder) setup. Radiances for the HIRS infrared channels and a set of 42 atmospheric profiles from the "Garand dataset" have been computed. Results of this intercomparison and a discussion of reasons of the observed differences are presented.

  2. ISMIP6 - initMIP: Greenland ice sheet model initialisation experiments

    NASA Astrophysics Data System (ADS)

    Goelzer, Heiko; Nowicki, Sophie; Payne, Tony; Larour, Eric; Abe Ouchi, Ayako; Gregory, Jonathan; Lipscomb, William; Seroussi, Helene; Shepherd, Andrew; Edwards, Tamsin

    2016-04-01

    Earlier large-scale Greenland ice sheet sea-level projections e.g. those run during ice2sea and SeaRISE initiatives have shown that ice sheet initialisation can have a large effect on the projections and gives rise to important uncertainties. This intercomparison exercise (initMIP) aims at comparing, evaluating and improving the initialization techniques used in the ice sheet modeling community and to estimate the associated uncertainties. It is the first in a series of ice sheet model intercomparison activities within ISMIP6 (Ice Sheet Model Intercomparison Project for CMIP6). The experiments are conceived for the large-scale Greenland ice sheet and are designed to allow intercomparison between participating models of 1) the initial present-day state of the ice sheet and 2) the response in two schematic forward experiments. The latter experiments serve to evaluate the initialisation in terms of model drift (forward run without any forcing) and response to a large perturbation (prescribed surface mass balance anomaly). We present and discuss first results of the intercomparison and highlight important uncertainties with respect to projections of the Greenland ice sheet sea-level contribution.

  3. An intercomparison of nitric oxide measurement techniques

    NASA Technical Reports Server (NTRS)

    Hoell, J. M., Jr.; Gregory, G. L.; Mcdougal, D. S.; Carroll, M. A.; Mcfarland, M.; Ridley, B. A.; Davis, D. D.; Bradshaw, J.; Rodgers, M. O.; Torres, A. L.

    1985-01-01

    Results from an intercomparison of techniques to measure tropospheric levels of nitric oxide (NO) are discussed. The intercomparison was part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and was conducted at Wallops Island, VA, in July 1983. Instruments intercompared included a laser-induced fluorescence system and two chemiluminescence instruments. The intercomparisons were performed with ambient air at NO mixing ratios ranging from 10 to 60 pptv and NO-enriched ambient air at mixing ratios from 20 to 170 pptv. All instruments sampled from a common manifold. The techniques exhibited a high degree of correlation among themselves and with changes in the NO mixing ratio. Agreement among the three techniques was placed at approximately + or - 30 percent. Within this level of agreement, no artifacts or species interferences were identified.

  4. A quality assurance program for clinical PDT

    NASA Astrophysics Data System (ADS)

    Dimofte, Andreea; Finlay, Jarod; Ong, Yi Hong; Zhu, Timothy C.

    2018-02-01

    Successful outcome of Photodynamic therapy (PDT) depends on accurate delivery of prescribed light dose. A quality assurance program is necessary to ensure that light dosimetry is correctly measured. We have instituted a QA program that include examination of long term calibration uncertainty of isotropic detectors for light fluence rate, power meter head intercomparison for laser power, stability of the light-emitting diode (LED) light source integrating sphere as a light fluence standard, laser output and calibration of in-vivo reflective fluorescence and absorption spectrometers. We examined the long term calibration uncertainty of isotropic detector sensitivity, defined as fluence rate per voltage. We calibrate the detector using the known calibrated light fluence rate of the LED light source built into an internally baffled 4" integrating sphere. LED light sources were examined using a 1mm diameter isotropic detector calibrated in a collimated beam. Wavelengths varying from 632nm to 690nm were used. The internal LED method gives an overall calibration accuracy of +/- 4%. Intercomparison among power meters was performed to determine the consistency of laser power and light fluence rate measured among different power meters. Power and fluence readings were measured and compared among detectors. A comparison of power and fluence reading among several power heads shows long term consistency for power and light fluence rate calibration to within 3% regardless of wavelength. The standard LED light source is used to calibrate the transmission difference between different channels for the diffuse reflective absorption and fluorescence contact probe as well as isotropic detectors used in PDT dose dosimeter.

  5. SPECT/CT demonstrating 131I retention in Warthin tumor on thyroid cancer survey scan.

    PubMed

    Zhang, Yuyang; Minoshima, Satoshi

    2013-09-01

    A 48-year-old male patient of papillary thyroid cancer, status post-thyroidectomy and node dissection, was referred to (131)I scan prior to radioiodine treatment. The images showed 1 additional focus of (131)I uptake in the right upper neck outside of the thyroid bed. SPECT/CT demonstrated 2 separate foci of radioiodine uptake in the right parotid gland, instead of neck lymph nodes. Diagnostic CT showed 2 corresponding soft tissue nodules in the right parotid gland which were confirmed latter by fine-needle aspiration to be Warthin tumors. This case illustrates a pivotal role of SPECT/CT in differential diagnosis of abnormal neck uptake on (131)I thyroid cancer scan.

  6. Whole-body scintigraphy with radioiodine-131. A comprehensive list of false-positives with some examples.

    PubMed

    McDougall, I R

    1995-10-01

    Whole-body scintigraphy with radioiodine-131 is an important diagnostic test in the management of patients with differentiated thyroid cancer who have undergone surgical treatment. The scan can demonstrate the presence of residual thyroid or functioning metastases in lymph nodes or distant sites. However, there are a number of potential pitfalls in the interpretation of this scan that could lead to a false-positive diagnosis of cancer. The scintiscans are presented for five patients in whom uptake outside of the thyroid was not due to functioning metastases. Some of these abnormalities are physiologic, such as uptake of iodine in the gastrointestinal tract. A comprehensive list of false-positive results are tabulated.

  7. Improved radioimmunotherapy of hematologic malignancies. Final technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Press, O.W.

    1996-08-15

    Experiments were performed to study the rates of endocytosis, intracellular routing, and metabolic degradation of radiolabeled monoclonal antibodies targeting tumor-associated antigens on human leukemia and lymphoma cells. An attempt was made to examine in vivo the effects of lysosomotropic amines and thioamides on the retention of radiolabeled monoclonal antibodies by tumor cells. Experiments also examined the impact of newer radioiodination techniques on the metabolic degradation of radioiodinated antibodies, and on the radioimmunoscintigraphy and radioimmunotherapy of neoplasms. The endocytosis, intracellular routing, and degradation of radioimmunoconjugates prepared with I-131, In-111, and Y-90 were compared. The utility of radioimmunoconjugates targeting oncogene products formore » the radioimmunotherapy and radioimmunoscintigraphy of cancer was investigated.« less

  8. MMAB Sea Ice Forecast Page

    Science.gov Websites

    verification statistics Grumbine, R. W., Virtual Floe Ice Drift Forecast Model Intercomparison, Weather and Forecasting, 13, 886-890, 1998. MMAB Note: Virtual Floe Ice Drift Forecast Model Intercomparison 1996 pdf ~47

  9. A new PUB-working group on SLope InterComparison Experiments (SLICE)

    NASA Astrophysics Data System (ADS)

    McGuire, K.; Retter, M.; Freer, J.; Troch, P.; McDonnell, J.

    2006-05-01

    The International Association of Hydrological Sciences (IAHS) decade on Prediction in Ungauged Basins (PUB) has the scientific goal to shift hydrology from calibration reliant models to new and rich understanding- based models. To support this, six PUB science themes have been developed under the PUB Science Steering group. Theme 1 covers basin inter-comparison and classification. The SLope InterComparison Experiment (SLICE) is a newly-formed working group aligned with theme 1. Its 2- year target is to promote the improved understanding of regional hydrological characteristics via hillslope inter- comparison studies and top-down analysis of data from hillslope experiments from around the world. It will further deliver the major building blocks of a catchment classification system. A first workshop of SLICE took place 26-28 September 2005 at the HJ Andrews Experimental Forest, Oregon, USA. 40 participants from seven countries were in attendance. The program consisted of keynote presentations on the state-of-the-art of hillslope hydrology, outlining a hillslope classification system, and through small group discussion, a focus on the following questions: a.) How can we capture flow path heterogeneity at the hillslope scale with residence time distributions? b.) Can networks help characterize hillslope subsurface systems? c.) What patterns are useful to characterize in a hillslope comparison context? d.) How does bedrock permeability condition hillslope response? e.) Can we actually observe pressure waves in the field and/or how likely are they to exist at the hillslope continuum scale? The poster presents an overview of the workshop outcomes and directions of future work.

  10. Results of the Greenland Ice Sheet Model Initialisation Experiments ISMIP6 - initMIP-Greenland

    NASA Astrophysics Data System (ADS)

    Goelzer, H.; Nowicki, S.; Edwards, T.; Beckley, M.; Abe-Ouchi, A.; Aschwanden, A.; Calov, R.; Gagliardini, O.; Gillet-chaulet, F.; Golledge, N. R.; Gregory, J. M.; Greve, R.; Humbert, A.; Huybrechts, P.; Larour, E. Y.; Lipscomb, W. H.; Le ´h, S.; Lee, V.; Kennedy, J. H.; Pattyn, F.; Payne, A. J.; Rodehacke, C. B.; Rückamp, M.; Saito, F.; Schlegel, N.; Seroussi, H. L.; Shepherd, A.; Sun, S.; Vandewal, R.; Ziemen, F. A.

    2016-12-01

    Earlier large-scale Greenland ice sheet sea-level projections e.g. those run during ice2sea and SeaRISE initiatives have shown that ice sheet initialisation can have a large effect on the projections and gives rise to important uncertainties. The goal of this intercomparison exercise (initMIP-Greenland) is to compare, evaluate and improve the initialization techniques used in the ice sheet modeling community and to estimate the associated uncertainties. It is the first in a series of ice sheet model intercomparison activities within ISMIP6 (Ice Sheet Model Intercomparison Project for CMIP6). Two experiments for the large-scale Greenland ice sheet have been designed to allow intercomparison between participating models of 1) the initial present-day state of the ice sheet and 2) the response in two schematic forward experiments. The forward experiments serve to evaluate the initialisation in terms of model drift (forward run without any forcing) and response to a large perturbation (prescribed surface mass balance anomaly). We present and discuss final results of the intercomparison and highlight important uncertainties with respect to projections of the Greenland ice sheet sea-level contribution.

  11. Absorption of Radionuclides from the Fukushima Nuclear Accident by a Novel Algal Strain

    PubMed Central

    Shimura, Hiroki; Itoh, Katsuhiko; Sugiyama, Atsushi; Ichijo, Sayaka; Ichijo, Masashi; Furuya, Fumihiko; Nakamura, Yuji; Kitahara, Ken; Kobayashi, Kazuhiko; Yukawa, Yasuhiro; Kobayashi, Tetsuro

    2012-01-01

    Large quantities of radionuclides have leaked from the Fukushima Daiichi Nuclear Power Plant into the surrounding environment. Effective prevention of health hazards resulting from radiation exposure will require the development of efficient and economical methods for decontaminating radioactive wastewater and aquatic ecosystems. Here we describe the accumulation of water-soluble radionuclides released by nuclear reactors by a novel strain of alga. The newly discovered green microalgae, Parachlorella sp. binos (Binos) has a thick alginate-containing extracellular matrix and abundant chloroplasts. When this strain was cultured with radioiodine, a light-dependent uptake of radioiodine was observed. In dark conditions, radioiodine uptake was induced by addition of hydrogen superoxide. High-resolution secondary ion mass spectrometry (SIMS) showed a localization of accumulated iodine in the cytosol. This alga also exhibited highly efficient incorporation of the radioactive isotopes strontium and cesium in a light-independent manner. SIMS analysis showed that strontium was distributed in the extracellular matrix of Binos. Finally we also showed the ability of this strain to accumulate radioactive nuclides from water and soil samples collected from a heavily contaminated area in Fukushima. Our results demonstrate that Binos could be applied to the decontamination of iodine, strontium and cesium radioisotopes, which are most commonly encountered after nuclear reactor accidents. PMID:22984475

  12. Modulation of thyroidal radioiodide uptake by oncological pipeline inhibitors and Apigenin.

    PubMed

    Lakshmanan, Aparna; Scarberry, Daniel; Green, Jill A; Zhang, Xiaoli; Selmi-Ruby, Samia; Jhiang, Sissy M

    2015-10-13

    Targeted radioiodine therapy for thyroid cancer is based on selective stimulation of Na+/I- Symporter (NIS)-mediated radioactive iodide uptake (RAIU) in thyroid cells by thyrotropin. Patients with advanced thyroid cancer do not benefit from radioiodine therapy due to reduced or absent NIS expression. To identify inhibitors that can be readily translated into clinical care, we examined oncological pipeline inhibitors targeting Akt, MEK, PI3K, Hsp90 or BRAF in their ability to increase RAIU in thyroid cells expressing BRAFV600E or RET/PTC3 oncogene. Our data showed that (1) PI3K inhibitor GDC-0941 outperformed other inhibitors in RAIU increase mainly by decreasing iodide efflux rate to a great extent; (2) RAIU increase by all inhibitors was extensively reduced by TGF-β, a cytokine secreted in the invasive fronts of thyroid cancers; (3) RAIU reduction by TGF-β was mainly mediated by NIS reduction and could be reversed by Apigenin, a plant-derived flavonoid; and (4) In the presence of TGF-β, GDC-0941 with Apigenin co-treatment had the highest RAIU level in both BRAFV600E expressing cells and RET/PTC3 expressing cells. Taken together, Apigenin may serve as a dietary supplement along with small molecule inhibitors to improve radioiodine therapeutic efficacy on invasive tumor margins thereby minimizing future metastatic events.

  13. Survival outcome of radioiodine therapy in post thyroidectomy thyroid carcinoma patients: Outcome of long term follow up

    NASA Astrophysics Data System (ADS)

    Haque, F.; Nahar, N.; Sultana, S.; Nasreen, F.; Jabin, Z.; Alam, A. S. M. M.

    2016-03-01

    The overall prognosis of patients with thyroid carcinoma is excellent whenever managed following best practice guidelines. Objective: To calculate sex and age group affected by thyroid cancer; to compare between single or multiple dose of radio ablation needed after thyroidectomy and to determine the percentage of patients become disease free during their follow up. Methods: This was a retrospective study done in NINMAS, Bangladesh on 687 patients from 1984 to 2004. In all cases total or near total thyroidectomy was done before commencing radioiodine therapy. Patients TG level, neck ultrasonography, thyroid scan, whole body I131 scans, neck examination were done every six monthly/yearly. Results: Among 687 patients, female were more sufferers (68.1%) and female to male ratio was 2:1. Age group 19-40 years was mostly affected (57.8%). Most common type seen was papillary carcinoma (81.8%). After ablation 100 patients did not follow-up. Total 237 patients discontinued within 4 years. Remaining 450 patients undergone regular follow-up for 5 years and more, 394 were disease free (87.6%). Total recurrence of metastasis was 23 and 12 patients expired at different times. Conclusions: Long-term regular follow-up is necessary after radioiodine ablation to become free of disease.

  14. Radioiodine Biogeochemistry and Prevalence in Groundwater

    PubMed Central

    Kaplan, D. I.; Denham, M. E.; Zhang, S.; Yeager, C.; Xu, C.; Schwehr, K. A.; Li, H. P.; Ho, Y. F.; Wellman, D.; Santschi, P. H.

    2014-01-01

    129I is commonly either the top or among the top risk drivers, along with 99Tc, at radiological waste disposal sites and contaminated groundwater sites where nuclear material fabrication or reprocessing has occurred. The risk stems largely from 129I having a high toxicity, a high bioaccumulation factor (90% of all the body's iodine concentrates in the thyroid), a high inventory at source terms (due to its high fission yield), an extremely long half-life (16M years), and rapid mobility in the subsurface environment. Another important reason that 129I is a key risk driver is that there is uncertainty regarding its biogeochemical fate and transport in the environment. We typically can define 129I mass balance and flux at sites, but cannot predict accurately its response to changes in the environment. As a consequence of some of these characteristics, 129I has a very low drinking water standard, which is set at 1 pCi/L, the lowest of all radionuclides in the Federal Register. Recently, significant advancements have been made in detecting iodine species at ambient groundwater concentrations, defining the nature of the organic matter and iodine bond, and quantifying the role of naturally occurring sediment microbes to promote iodine oxidation and reduction. These recent studies have led to a more mechanistic understanding of radioiodine biogeochemistry. The objective of this review is to describe these advances and to provide a state of the science of radioiodine biogeochemistry relevant to its fate and transport in the terrestrial environment and provide information useful for making decisions regarding the stewardship and remediation of 129I contaminated sites. As part of this review, knowledge gaps were identified that would significantly advance the goals of basic and applied research programs for accelerating 129I environmental remediation and reducing uncertainty associated with disposal of 129I waste. Together the information gained from addressing these knowledge gaps will not alter the observation that 129I is primarily mobile, but it will likely permit demonstration that the entire 129I pool in the source term is not moving at the same rate and some may be tightly bound to the sediment, thereby smearing the modeled 129I peak and reducing maximum calculated risk. PMID:25264421

  15. Best Practice Guidelines for Pre-Launch Characterization and Calibration of Instruments for Passive Optical Remote Sensing1

    PubMed Central

    Datla, R. U.; Rice, J. P.; Lykke, K. R.; Johnson, B. C.; Butler, J. J.; Xiong, X.

    2011-01-01

    The pre-launch characterization and calibration of remote sensing instruments should be planned and carried out in conjunction with their design and development to meet the mission requirements. The onboard calibrators such as blackbodies and the sensors such as spectral radiometers should be characterized and calibrated using SI traceable standards. In the case of earth remote sensing, this allows inter-comparison and intercalibration of different sensors in space to create global time series of climate records of high accuracy where some inevitable data gaps can be easily bridged. The recommended best practice guidelines for this pre-launch effort is presented based on experience gained at National Institute of Standards and Technology (NIST), National Aeronautics and Space Administration (NASA) and National Oceanic and Atmospheric Administration (NOAA) programs over the past two decades. The currently available radiometric standards and calibration facilities at NIST serving the remote sensing community are described. Examples of best practice calibrations and intercomparisons to build SI (international System of Units) traceable uncertainty budget in the instrumentation used for preflight satellite sensor calibration and validation are presented. PMID:26989588

  16. Composite Study Of Aerosol Long-Range Transport Events From East Asia And North America

    NASA Astrophysics Data System (ADS)

    Jiang, X.; Waliser, D. E.; Guan, B.; Xavier, P.; Petch, J.; Klingaman, N. P.; Woolnough, S.

    2011-12-01

    While the Madden-Julian Oscillation (MJO) exerts pronounced influences on global climate and weather systems, current general circulation models (GCMs) exhibit rather limited capability in representing this prominent tropical variability mode. Meanwhile, the fundamental physics of the MJO are still elusive. Given the central role of the diabatic heating for prevailing MJO theories and demands for reducing the model deficiencies in simulating the MJO, a global model inter-comparison project on diabatic processes and vertical heating structure associated with the MJO has been coordinated through a joint effort by the WCRP-WWRP/THORPEX YOTC MJO Task Force and GEWEX GASS Program. In this presentation, progress of this model inter-comparison project will be reported, with main focus on climate simulations from about 27 atmosphere-only and coupled GCMs. Vertical structures of heating and diabatic processes associated with the MJO based on multi-model simulations will be presented along with their reanalysis and satellite estimate counterparts. Key processes possibly responsible for a realistic simulation of the MJO, including moisture-convection interaction, gross moist stability, ocean coupling, and surface heat flux, will be discussed.

  17. Best Practice Guidelines for Pre-Launch Characterization and Calibration of Instruments for Passive Optical Remote Sensing.

    PubMed

    Datla, R U; Rice, J P; Lykke, K R; Johnson, B C; Butler, J J; Xiong, X

    2011-01-01

    The pre-launch characterization and calibration of remote sensing instruments should be planned and carried out in conjunction with their design and development to meet the mission requirements. The onboard calibrators such as blackbodies and the sensors such as spectral radiometers should be characterized and calibrated using SI traceable standards. In the case of earth remote sensing, this allows inter-comparison and intercalibration of different sensors in space to create global time series of climate records of high accuracy where some inevitable data gaps can be easily bridged. The recommended best practice guidelines for this pre-launch effort is presented based on experience gained at National Institute of Standards and Technology (NIST), National Aeronautics and Space Administration (NASA) and National Oceanic and Atmospheric Administration (NOAA) programs over the past two decades. The currently available radiometric standards and calibration facilities at NIST serving the remote sensing community are described. Examples of best practice calibrations and intercomparisons to build SI (international System of Units) traceable uncertainty budget in the instrumentation used for preflight satellite sensor calibration and validation are presented.

  18. Forward Model Studies of Water Vapor Using Scanning Microwave Radiometers, Global Positioning System, and Radiosondes during the Cloudiness Intercomparison Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mattioli, Vinia; Westwater, Ed R.; Gutman, S.

    2005-05-01

    Brightness temperatures computed from five absorption models and radiosonde observations were analyzed by comparing them with measurements from three microwave radiometers at 23.8 and 31.4 GHz. Data were obtained during the Cloudiness Inter-Comparison experiment at the U.S. Department of Energy's Atmospheric Radiation Measurement Program's (ARM) site in North-Central Oklahoma in 2003. The radiometers were calibrated using two procedures, the so-called instantaneous ?tipcal? method and an automatic self-calibration algorithm. Measurements from the radiometers were in agreement, with less than a 0.4-K difference during clear skies, when the instantaneous method was applied. Brightness temperatures from the radiometer and the radiosonde showed anmore » agreement of less than 0.55 K when the most recent absorption models were considered. Precipitable water vapor (PWV) computed from the radiometers were also compared to the PWV derived from a Global Positioning System station that operates at the ARM site. The instruments agree to within 0.1 cm in PWV retrieval.« less

  19. 99mTc-EDDA/HYNIC-TOC in the diagnosis of differentiated thyroid carcinoma refractory to radioiodine treatment.

    PubMed

    Czepczyński, Rafał; Gryczyńska, Maria; Ruchała, Marek

    2016-01-01

    In majority of cases of differentiated thyroid carcinoma (DTC), the ablative radioiodine treatment shows high efficacy. In a small number of patients, mechanism of selective iodine uptake by the DTC cells is insufficient and alternative methods of diagnosis and treatment are needed. As demonstrated in vitro, DTC cells show expression of somatostatin recep-tors. Radiolabeled somatostatin analogs are widely used in the diagnosis of neuroendocrine tumors. The aim of the study was to evaluate the utility of peptide receptor scintigraphy with the use of 99mTc-EDDA/HYNIC-TOC in the diagnosis of DTC in patients with elevated thyroglobulin concentrations (Tg), negative WBS and no effect of the consecutive radioiodine therapies. Whole body scintigraphy as well as SPECT of neck and chest were performed 3 and 24 h after i.v. administration of 740 MBq 99mTc-EDDA/HYNIC-TOC. The obtained images were compared with other radionuclide and ra-diological imaging methods. Forty-three patients with DTC after surgery and ablative radioiodine treatment with negative WBS and elevated Tg were qualified. Patients' age: 18-83 years (mean 58.0). SRS showed foci of tracer accumulation in 29 cases (67.4%). Sensitivity was 69.0% specificity 78.6%. SRS correctly identified local recurrence in 8 pts., metastatic lymph nodes in 19 pts., lung metastases in 12 pts. and bone metastases in 5 pts. SRS showed high sensitivity in the detection of metastatic lymph nodes (100%) and bone metastases (83.3%) and lung metastases (63.2%). Positive SRS was found in pts. with higher Tg concentrations (130 ± 144 vs. 30 ± 54 ng/ml). Scintigraphy with the use of the studied technetium-99m-labeled somatostatin analog is useful in the evaluation of patients with advanced DTC. It shows relatively good sensitivity and specificity but not high enough to be recommended as a routine imaging method. The role of somatostatin receptor scintigraphy in DTC is complementary to other imaging modalities.

  20. Satellite Derived Volcanic Ash Product Inter-Comparison in Support to SCOPE-Nowcasting

    NASA Astrophysics Data System (ADS)

    Siddans, Richard; Thomas, Gareth; Pavolonis, Mike; Bojinski, Stephan

    2016-04-01

    In support of aeronautical meteorological services, WMO organized a satellite-based volcanic ash retrieval algorithm inter-comparison activity, to improve the consistency of quantitative volcanic ash products from satellites, under the Sustained, Coordinated Processing of Environmental Satellite Data for Nowcasting (SCOPEe Nowcasting) initiative (http:/ jwww.wmo.int/pagesjprogjsatjscopee nowcasting_en.php). The aims of the intercomparison were as follows: 1. Select cases (Sarychev Peak 2009, Eyjafyallajökull 2010, Grimsvötn 2011, Puyehue-Cordón Caulle 2011, Kirishimayama 2011, Kelut 2014), and quantify the differences between satellite-derived volcanic ash cloud properties derived from different techniques and sensors; 2. Establish a basic validation protocol for satellite-derived volcanic ash cloud properties; 3. Document the strengths and weaknesses of different remote sensing approaches as a function of satellite sensor; 4. Standardize the units and quality flags associated with volcanic cloud geophysical parameters; 5. Provide recommendations to Volcanic Ash Advisory Centers (VAACs) and other users on how to best to utilize quantitative satellite products in operations; 6. Create a "road map" for future volcanic ash related scientific developments and inter-comparison/validation activities that can also be applied to SO2 clouds and emergent volcanic clouds. Volcanic ash satellite remote sensing experts from operational and research organizations were encouraged to participate in the inter-comparison activity, to establish the plans for the inter-comparison and to submit data sets. RAL was contracted by EUMETSAT to perform a systematic inter-comparison of all submitted datasets and results were reported at the WMO International Volcanic Ash Inter-comparison Meeting to held on 29 June - 2 July 2015 in Madison, WI, USA (http:/ /cimss.ssec.wisc.edujmeetings/vol_ash14). 26 different data sets were submitted, from a range of passive imagers and spectrometers and these were inter-compared against each other and against validation data such as CALIPSO lidar, ground-based lidar and aircraft observations. Results of the comparison exercise will be presented together with the conclusions and recommendations arising from the activity.

  1. Assessing agricultural risks of climate change in the 21st century in a global gridded crop model intercomparison

    PubMed Central

    Rosenzweig, Cynthia; Elliott, Joshua; Deryng, Delphine; Ruane, Alex C.; Müller, Christoph; Arneth, Almut; Boote, Kenneth J.; Folberth, Christian; Glotter, Michael; Khabarov, Nikolay; Neumann, Kathleen; Piontek, Franziska; Pugh, Thomas A. M.; Schmid, Erwin; Stehfest, Elke; Yang, Hong; Jones, James W.

    2014-01-01

    Here we present the results from an intercomparison of multiple global gridded crop models (GGCMs) within the framework of the Agricultural Model Intercomparison and Improvement Project and the Inter-Sectoral Impacts Model Intercomparison Project. Results indicate strong negative effects of climate change, especially at higher levels of warming and at low latitudes; models that include explicit nitrogen stress project more severe impacts. Across seven GGCMs, five global climate models, and four representative concentration pathways, model agreement on direction of yield changes is found in many major agricultural regions at both low and high latitudes; however, reducing uncertainty in sign of response in mid-latitude regions remains a challenge. Uncertainties related to the representation of carbon dioxide, nitrogen, and high temperature effects demonstrated here show that further research is urgently needed to better understand effects of climate change on agricultural production and to devise targeted adaptation strategies. PMID:24344314

  2. Assessing Agricultural Risks of Climate Change in the 21st Century in a Global Gridded Crop Model Intercomparison

    NASA Technical Reports Server (NTRS)

    Rosenzweig, Cynthia E.; Elliott, Joshua; Deryng, Delphine; Ruane, Alex C.; Mueller, Christoph; Arneth, Almut; Boote, Kenneth J.; Folberth, Christian; Glotter, Michael; Khabarov, Nikolay

    2014-01-01

    Here we present the results from an intercomparison of multiple global gridded crop models (GGCMs) within the framework of the Agricultural Model Intercomparison and Improvement Project and the Inter-Sectoral Impacts Model Intercomparison Project. Results indicate strong negative effects of climate change, especially at higher levels of warming and at low latitudes; models that include explicit nitrogen stress project more severe impacts. Across seven GGCMs, five global climate models, and four representative concentration pathways, model agreement on direction of yield changes is found in many major agricultural regions at both low and high latitudes; however, reducing uncertainty in sign of response in mid-latitude regions remains a challenge. Uncertainties related to the representation of carbon dioxide, nitrogen, and high temperature effects demonstrated here show that further research is urgently needed to better understand effects of climate change on agricultural production and to devise targeted adaptation strategies.

  3. Our solution for fusion of simultaneusly acquired whole body scintigrams and optical images, as usesful tool in clinical practice in patients with differentiated thyroid carcinomas after radioiodine therapy. A useful tool in clinical practice.

    PubMed

    Matovic, Milovan; Jankovic, Milica; Barjaktarovic, Marko; Jeremic, Marija

    2017-01-01

    After radioiodine therapy of differentiated thyroid cancer (DTC) patients, whole body scintigraphy (WBS) is standard procedure before releasing the patient from the hospital. A common problem is the precise localization of regions where the iod-avide tissue is located. Sometimes is practically impossible to perform precise topographic localization of such regions. In order to face this problem, we have developed a low-cost Vision-Fusion system for web-camera image acquisition simultaneously with routine scintigraphic whole body acquisition including the algorithm for fusion of images given from both cameras. For image acquisition in the gamma part of the spectra we used e.cam dual head gamma camera (Siemens, Erlangen, Germany) in WBS modality, with matrix size of 256×1024 pixels and bed speed of 6cm/min, equipped with high energy collimator. For optical image acquisition in visible part of spectra we have used web-camera model C905 (Logitech, USA) with Carl Zeiss® optics, native resolution 1600×1200 pixels, 34 o field of view, 30g weight, with autofocus option turned "off" and auto white balance turned "on". Web camera is connected to upper head of gamma camera (GC) by a holder of lightweight aluminum rod and a plexiglas adapter. Our own Vision-Fusion software for image acquisition and coregistration was developed using NI LabVIEW programming environment 2015 (National Instruments, Texas, USA) and two additional LabVIEW modules: NI Vision Acquisition Software (VAS) and NI Vision Development Module (VDM). Vision acquisition software enables communication and control between laptop computer and web-camera. Vision development module is image processing library used for image preprocessing and fusion. Software starts the web-camera image acquisition before starting image acquisition on GC and stops it when GC completes the acquisition. Web-camera is in continuous acquisition mode with frame rate f depending on speed of patient bed movement v (f=v/∆ cm , where ∆ cm is a displacement step that can be changed in Settings option of Vision-Fusion software; by default, ∆ cm is set to 1cm corresponding to ∆ p =15 pixels). All images captured while patient's bed is moving are processed. Movement of patient's bed is checked using cross-correlation of two successive images. After each image capturing, algorithm extracts the central region of interest (ROI) of the image, with the same width as captured image (1600 pixels) and the height that is equal to the ∆ p displacement in pixels. All extracted central ROI are placed next to each other in the overall whole-body image. Stacking of narrow central ROI introduces negligible distortion in the overall whole-body image. The first step for fusion of the scintigram and the optical image was determination of spatial transformation between them. We have made an experiment with two markers (point radioactivity sources of 99m Tc pertechnetate 1MBq) visible in both images (WBS and optical) to find transformation of coordinates between images. The distance between point markers is used for spatial coregistration of the gamma and optical images. At the end of coregistration process, gamma image is rescaled in spatial domain and added to the optical image (green or red channel, amplification changeable from user interface). We tested our system for 10 patients with DTC who received radioiodine therapy (8 women and two men, with average age of 50.10±12.26 years). Five patients received 5.55Gbq, three 3.70GBq and two 1.85GBq. Whole-body scintigraphy and optical image acquisition were performed 72 hours after application of radioiodine therapy. Based on our first results during clinical testing of our system, we can conclude that our system can improve diagnostic possibility of whole body scintigraphy to detect thyroid remnant tissue in patients with DTC after radioiodine therapy.

  4. Computerised curve deconvolution of TL/OSL curves using a popular spreadsheet program.

    PubMed

    Afouxenidis, D; Polymeris, G S; Tsirliganis, N C; Kitis, G

    2012-05-01

    This paper exploits the possibility of using commercial software for thermoluminescence and optically stimulated luminescence curve deconvolution analysis. The widely used software package Microsoft Excel, with the Solver utility has been used to perform deconvolution analysis to both experimental and reference glow curves resulted from the GLOw Curve ANalysis INtercomparison project. The simple interface of this programme combined with the powerful Solver utility, allows the analysis of complex stimulated luminescence curves into their components and the evaluation of the associated luminescence parameters.

  5. Low level measurements of atmospheric DMS, H2S, and SO2 for GTE/CITE-3

    NASA Technical Reports Server (NTRS)

    Saltzman, Eric; Cooper, David

    1991-01-01

    This project involved the measurement of atmospheric dimethylsulfide (DMS) and hydrogen sulfide (H2S) as part of the GTE/CITE-3 instrument intercomparison program. The two instruments were adapted for use on the NASA Electra aircraft and participated in all phases of the mission. This included ground-based measurements of NIST-provided standard gases and a series of airborne missions over the Western Atlantic Ocean. Analytical techniques used are described and the results are summarized.

  6. Middle Atmosphere Program. Handbook for MAP. Volume 12: Coordinated Study of the Behavior of the Middle Atmosphere in Winter (PMP-1) Workshops

    NASA Technical Reports Server (NTRS)

    Rodgers, C. D. (Editor)

    1984-01-01

    Intercomparison of middle atmosphere meteorological data from a variety of sources is discussed. The primary aim was to intercompare data on stratospheric and mesospheric temperatures from a variety of sounding systems in order to characterize the differences, to understand the reasons for them, and to help users of the data to understand how these differences will affect derived quantities such as heat and momentum fluxes which are significant in studies of stratospheric dynamics.

  7. Semi-automatic version of the potentiometric titration method for characterization of uranium compounds.

    PubMed

    Cristiano, Bárbara F G; Delgado, José Ubiratan; da Silva, José Wanderley S; de Barros, Pedro D; de Araújo, Radier M S; Dias, Fábio C; Lopes, Ricardo T

    2012-09-01

    The potentiometric titration method was used for characterization of uranium compounds to be applied in intercomparison programs. The method is applied with traceability assured using a potassium dichromate primary standard. A semi-automatic version was developed to reduce the analysis time and the operator variation. The standard uncertainty in determining the total concentration of uranium was around 0.01%, which is suitable for uranium characterization and compatible with those obtained by manual techniques. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. International NMR-based Environmental Metabolomics Intercomparison Exercise

    EPA Science Inventory

    Several fundamental requirements must be met so that NMR-based metabolomics and the related technique of metabonomics can be formally adopted into environmental monitoring and chemical risk assessment. Here we report an intercomparison exercise which has evaluated the effectivene...

  9. Maintenance of biological activity of pertussis toxin radioiodinated while bound to fetuin-agarose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Armstrong, G.D.; Peppler, M.S.

    1987-05-01

    We developed a method to produce radioiodinated pertussis toxin (PT) which was active in the goose erythrocyte agglutination and CHO cell assay systems. The procedure used fetuin coupled to agarose to prevent inactivation of the toxin during the iodination reaction. Analysis of the labeled PT by affinity chromatography on fetuin-agarose and wheat germ agglutinin-agarose and by sodium dodecyl sulfate-polyacrylamide gel electrophoresis indicated that there were minimal amounts of labeled fetuin or other contaminants in the labeled PT preparations. All five of the subunits of the toxin appeared to be labeled by the procedure. The labeling method will facilitate further investigationsmore » into the nature of the interaction and activity of PT in host tissues.« less

  10. (99m)Tc HYNIC-TOC imaging and 177Lu DOTA-octreotate treatment in non-iodine-concentrating dedifferentiated thyroid carcinoma metastases: an unusual alternative diagnosis.

    PubMed

    Basu, Sandip; Joshi, Amit

    2014-07-01

    The value of Tc HYNIC-TOC scintigraphy clarifying skeletal and hepatic-predominant metastatic disease in a 55-year-old woman (diagnosed earlier to have papillary carcinoma thyroid and had undergone total thyroidectomy and radioiodine ablation) is illustrated. The whole-body radioiodine scan and battery of serum tumor markers were normal. Multiple metastatic foci in the liver and skeleton were Tc HYNIC-TOC avid. Serum chromogranin A level was substantially elevated (1771.60 ng/mL). This represents an unusual alternative diagnosis signified by a highly positive scan in the setting of apparent non-iodine-concentrating metastatic disease in a patient of differentiated thyroid carcinoma.

  11. Thyroid and parathyroid imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandler, M.P.; Patton, J.A.; Partain, C.L.

    1986-01-01

    This book describes the numerous modalities currently used in the diagnosis and treatment of both thyroid and parathyroid disorders. Each modality is fully explained and then evaluated in terms of benefits and limitations in the clinical context. Contents: Production and Quality Control of Radiopharmaceutics Used for Diagnosis and Therapy in Thyroid and Parathyroid Disorders. Basic Physics. Nuclear Instrumentation. Radioimmunoassay: Thyroid Function Tests. Quality Control. Embryology, Anatomy, Physiology, and Thyroid Function Studies. Scintigraphic Thyroid Imaging. Neonatal and Pediatric Thyroid Imaging. Radioiodine Thyroid Uptake Measurement. Radioiodine Treatment of Thyroid Disorders. Radiation Dosimetry of Diagnostic Procedures. Radiation Safety Procedures for High-Level I-131 Therapies.more » X-Ray Fluorescent Scanning. Thyroid Sonography. Computed Tomography in Thyroid Disease. Magnetic Resonance Imaging in Thyroid Disease. Parathyroid Imaging.« less

  12. Cyclotron production of I-123: An evaluation of the nuclear reactions which produce this isotope

    NASA Technical Reports Server (NTRS)

    Sodd, V. J.; Scholz, K. L.; Blue, J. W.; Wellman, H. N.

    1970-01-01

    The use of the various nuclear reactions is described by which I-123,a low radiation dose radiopharmaceutical, can be cyclotron-produced. Methods of directly producing I-123 and those which indirectly produce the radionuclide through the beta (+) decay of its nautral precursor, Xe-123. It is impossible to separate from the radioiodine contaminants, notably I-124, which occur in the direct method. Thus, it is preferable to produce pure I-123 from Xe-123 which is easily separated from the radioiodines. Among the characteristics of I-123 is the capability of reducing the patient dose in a thyroid uptake measurement to a very small percentage of that delivered by the more commonly used I-131.

  13. PM 2.5 ORGANIC SPECIATION INTERCOMPARISON RESULTS

    EPA Science Inventory

    This abstract describes a poster on results to a laboratory intercomparison of organic aerosol speciation analysis to be presented at the 2006 International Aerosol Conference sponsored by the American Association for Aerosol Research in St. Paul, Minnesota on September 10-15. T...

  14. Total ozone measurement: Intercomparison of prototype New Zealand filter instrument and Dobson spectrophotometer

    NASA Technical Reports Server (NTRS)

    Basher, R. E.

    1978-01-01

    A five month intercomparison showed that the total ozone amounts of a prototype narrowband interference filter instrument were 7% less than those of a Dobson instrument for an ozone range of 0.300 to 0.500 atm cm and for airmasses less than two. The 7% bias was within the intercomparison calibration uncertainty. An airmass dependence in the Dobson instrument made the bias relationship airmass-dependent but the filter instrument's ozone values were generally constant to 2% up to an airmass of four. Long term drift in the bias was negligible.

  15. The Inter-Sectoral Impact Model Intercomparison Project (ISI–MIP): Project framework

    PubMed Central

    Warszawski, Lila; Frieler, Katja; Huber, Veronika; Piontek, Franziska; Serdeczny, Olivia; Schewe, Jacob

    2014-01-01

    The Inter-Sectoral Impact Model Intercomparison Project offers a framework to compare climate impact projections in different sectors and at different scales. Consistent climate and socio-economic input data provide the basis for a cross-sectoral integration of impact projections. The project is designed to enable quantitative synthesis of climate change impacts at different levels of global warming. This report briefly outlines the objectives and framework of the first, fast-tracked phase of Inter-Sectoral Impact Model Intercomparison Project, based on global impact models, and provides an overview of the participating models, input data, and scenario set-up. PMID:24344316

  16. Fabrication and characterization of optical super-smooth surfaces

    NASA Astrophysics Data System (ADS)

    Schmitt, Dirk-Roger; Kratz, Frank; Ringel, Gabriele A.; Mangelsdorf, Juergen; Creuzet, Francois; Garratt, John D.

    1995-08-01

    Intercomparison roughness measurements have been carried out at supersmooth artefacts fabricated from BK7, fused silica, and Zerodur. The surface parameters were determined using a special prototype of the mechanical profiler Nanostep (Rank Taylor Hobson), the Optical Heterodyne Profiler Z5500 (Zygo), and an Atomic Force Microscope (Park Scientific) with an improved acquisition technique. The intercomparison was performed after the range of collected spatial wavelength for each instrument was adjusted using digital filtering techniques. It is demonstrated for different roughness ranges that are applied superpolishing techniques yield supersmooth artefacts which can be used for more intercomparisons.

  17. Water vapour inter-comparison effort in the framework of the hydrological cycle in the mediterranean experiment - special observation period (hymex-sop1)

    NASA Astrophysics Data System (ADS)

    Summa, Donato; Di Girolamo, Paolo; Flamant, Cyrille; De Rosa, Benedetto; Cacciani, Marco; Stelitano, Dario

    2018-04-01

    Accurate measurements of the vertical profiles of water vapour are of paramount importance for most key areas of atmospheric sciences. A comprehensive inter-comparison between different remote sensing and in-situ sensors has been carried out in the frame work of the first Special Observing Period of the Hydrological cycle in the Mediterranean Experiment for the purpose of obtaining accurate error estimates for these sensors. The inter-comparison involves a ground-based Raman lidar (BASIL), an airborne DIAL (LEANDRE2), a microwave radiometer, radiosondes and aircraft in-situ sensors.

  18. Evaluation of the annual Canadian biodosimetry network intercomparisons

    PubMed Central

    Wilkins, Ruth C.; Beaton-Green, Lindsay A.; Lachapelle, Sylvie; Kutzner, Barbara C.; Ferrarotto, Catherine; Chauhan, Vinita; Marro, Leonora; Livingston, Gordon K.; Boulay Greene, Hillary; Flegal, Farrah N.

    2015-01-01

    Abstract Purpose: To evaluate the importance of annual intercomparisons for maintaining the capacity and capabilities of a well-established biodosimetry network in conjunction with assessing efficient and effective analysis methods for emergency response. Materials and methods: Annual intercomparisons were conducted between laboratories in the Canadian National Biological Dosimetry Response Plan. Intercomparisons were performed over a six-year period and comprised of the shipment of 10–12 irradiated, blinded blood samples for analysis by each of the participating laboratories. Dose estimates were determined by each laboratory using the dicentric chromosome assay (conventional and QuickScan scoring) and where possible the cytokinesis block micronucleus (CBMN) assay. Dose estimates were returned to the lead laboratory for evaluation and comparison. Results: Individual laboratories performed comparably from year to year with only slight fluctuations in performance. Dose estimates using the dicentric chromosome assay were accurate about 80% of the time and the QuickScan method for scoring the dicentric chromosome assay was proven to reduce the time of analysis without having a significant effect on the dose estimates. Although analysis with the CBMN assay was comparable to QuickScan scoring with respect to speed, the accuracy of the dose estimates was greatly reduced. Conclusions: Annual intercomparisons are necessary to maintain a network of laboratories for emergency response biodosimetry as they evoke confidence in their capabilities. PMID:25670072

  19. Climate Science's Globally Distributed Infrastructure

    NASA Astrophysics Data System (ADS)

    Williams, D. N.

    2016-12-01

    The Earth System Grid Federation (ESGF) is primarily funded by the Department of Energy's (DOE's) Office of Science (the Office of Biological and Environmental Research [BER] Climate Data Informatics Program and the Office of Advanced Scientific Computing Research Next Generation Network for Science Program), the National Oceanic and Atmospheric Administration (NOAA), the National Aeronautics and Space Administration (NASA), and the National Science Foundation (NSF), the European Infrastructure for the European Network for Earth System Modeling (IS-ENES), and the Australian National University (ANU). Support also comes from other U.S. federal and international agencies. The federation works across multiple worldwide data centers and spans seven international network organizations to provide users with the ability to access, analyze, and visualize data using a globally federated collection of networks, computers, and software. Its architecture employs a series of geographically distributed peer nodes that are independently administered and united by common federation protocols and application programming interfaces (APIs). The full ESGF infrastructure has now been adopted by multiple Earth science projects and allows access to petabytes of geophysical data, including the Coupled Model Intercomparison Project (CMIP; output used by the Intergovernmental Panel on Climate Change assessment reports), multiple model intercomparison projects (MIPs; endorsed by the World Climate Research Programme [WCRP]), and the Accelerated Climate Modeling for Energy (ACME; ESGF is included in the overarching ACME workflow process to store model output). ESGF is a successful example of integration of disparate open-source technologies into a cohesive functional system that serves the needs the global climate science community. Data served by ESGF includes not only model output but also observational data from satellites and instruments, reanalysis, and generated images.

  20. CAUSES: Diagnosis of the Summertime Warm Bias in CMIP5 Climate Models at the ARM Southern Great Plains Site

    NASA Astrophysics Data System (ADS)

    Zhang, Chengzhu; Xie, Shaocheng; Klein, Stephen A.; Ma, Hsi-yen; Tang, Shuaiqi; Van Weverberg, Kwinten; Morcrette, Cyril J.; Petch, Jon

    2018-03-01

    All the weather and climate models participating in the Clouds Above the United States and Errors at the Surface project show a summertime surface air temperature (T2 m) warm bias in the region of the central United States. To understand the warm bias in long-term climate simulations, we assess the Atmospheric Model Intercomparison Project simulations from the Coupled Model Intercomparison Project Phase 5, with long-term observations mainly from the Atmospheric Radiation Measurement program Southern Great Plains site. Quantities related to the surface energy and water budget, and large-scale circulation are analyzed to identify possible factors and plausible links involved in the warm bias. The systematic warm season bias is characterized by an overestimation of T2 m and underestimation of surface humidity, precipitation, and precipitable water. Accompanying the warm bias is an overestimation of absorbed solar radiation at the surface, which is due to a combination of insufficient cloud reflection and clear-sky shortwave absorption by water vapor and an underestimation in surface albedo. The bias in cloud is shown to contribute most to the radiation bias. The surface layer soil moisture impacts T2 m through its control on evaporative fraction. The error in evaporative fraction is another important contributor to T2 m. Similar sources of error are found in hindcast from other Clouds Above the United States and Errors at the Surface studies. In Atmospheric Model Intercomparison Project simulations, biases in meridional wind velocity associated with the low-level jet and the 500 hPa vertical velocity may also relate to T2 m bias through their control on the surface energy and water budget.

  1. Dosimetry-based treatment for Graves' disease.

    PubMed

    Hyer, Steve L; Pratt, Brenda; Gray, Matthew; Chittenden, Sarah; Du, Yong; Harmer, Clive L; Flux, Glenn D

    2018-06-01

    The aim of this retrospective study was to assess the long-term outcome of a personalized dosimetry approach in Graves' disease aiming to render patients euthyroid from a planned thyroid absorbed dose of 60 Gy. A total of 284 patients with Graves' disease were followed prospectively following administration of radioiodine calculated to deliver an absorbed dose of 60 Gy. Patients with cardiac disease were excluded. Outcomes were analysed at yearly intervals for up to 10 years with a median follow-up of 37.5 months. A single radioiodine administration was sufficient to render a patient either euthyroid or hypothyroid in 175 (62%) patients, the remainder requiring further radioiodine. The median radioactivity required to deliver 60 Gy was 77 MBq. Less than 2% patients required 400-600 MBq, the standard activity administered in many centres. In the cohort receiving a single administration, 38, 32 and 26% were euthyroid on no specific thyroid medication at 3, 5 and 10 years, respectively. Larger thyroid volumes were associated with the need for further therapy. The presence of nodules on ultrasonography did not adversely affect treatment outcome. A personalized dosimetric approach delayed the long-term onset of hypothyroidism in 26% of patients. This was achieved using much lower administered activities than currently recommended. Future studies will aim to identify those patients who would benefit most from this approach.

  2. Modulation of thyroidal radioiodide uptake by oncological pipeline inhibitors and Apigenin

    PubMed Central

    Lakshmanan, Aparna; Scarberry, Daniel; Green, Jill A.; Zhang, Xiaoli; Selmi-Ruby, Samia; Jhiang, Sissy M.

    2015-01-01

    Targeted radioiodine therapy for thyroid cancer is based on selective stimulation of Na+/I− Symporter (NIS)-mediated radioactive iodide uptake (RAIU) in thyroid cells by thyrotropin. Patients with advanced thyroid cancer do not benefit from radioiodine therapy due to reduced or absent NIS expression. To identify inhibitors that can be readily translated into clinical care, we examined oncological pipeline inhibitors targeting Akt, MEK, PI3K, Hsp90 or BRAF in their ability to increase RAIU in thyroid cells expressing BRAFV600E or RET/PTC3 oncogene. Our data showed that (1) PI3K inhibitor GDC-0941 outperformed other inhibitors in RAIU increase mainly by decreasing iodide efflux rate to a great extent; (2) RAIU increase by all inhibitors was extensively reduced by TGF-β, a cytokine secreted in the invasive fronts of thyroid cancers; (3) RAIU reduction by TGF-β was mainly mediated by NIS reduction and could be reversed by Apigenin, a plant-derived flavonoid; and (4) In the presence of TGF-β, GDC-0941 with Apigenin co-treatment had the highest RAIU level in both BRAFV600E expressing cells and RET/PTC3 expressing cells. Taken together, Apigenin may serve as a dietary supplement along with small molecule inhibitors to improve radioiodine therapeutic efficacy on invasive tumor margins thereby minimizing future metastatic events. PMID:26397139

  3. Joint ARM/GCSS/SPARC TWP-ICE CRM Intercomparison Study: Description, Preliminary Results, and Invitation to Participate

    NASA Astrophysics Data System (ADS)

    Fridlind, A. M.; Ackerman, A. S.; Allen, G.; Beringer, J.; Comstock, J. M.; Field, P. R.; Gallagher, M.; Hacker, J. M.; Hume, T.; Jakob, C.; Liu, G.; Long, C. N.; Mather, J. H.; May, P. T.; McCoy, R. F.; McFarlane, S. A.; McFarquhar, G. M.; Minnis, P.; Petch, J. C.; Schumacher, C.; Turner, D. D.; Whiteway, J. A.; Williams, C. R.; Williams, P. I.; Xie, S.; Zhang, M.

    2008-12-01

    The 2006 Tropical Warm Pool - International Cloud Experiment (TWP-ICE) is 'the first field program in the tropics that attempted to describe the evolution of tropical convection, including the large-scale heat, moisture, and momentum budgets at 3-hourly time resolution, while at the same time obtaining detailed observations of cloud properties and the impact of the clouds on the environment' [May et al., 2008]. A cloud- resolving model (CRM) intercomparison based on TWP-ICE is now being undertaken by the Atmospheric Radiation Measurement (ARM), GEWEX Cloud Systems Study (GCSS), and Stratospheric Processes And their Role in Climate (SPARC) programs. We summarize the 16-day case study and the wealth of data being used to provide initial and boundary conditions, and evaluate some preliminary findings in the context of existing theories of moisture evolution in the tropical tropopause layer (TTL). Overall, simulated cloud fields evolve realistically by many measures. Budgets indicate that simulated convective flux convergence of water vapor is always positive or near zero at TTL elevations, except locally at lower levels during the driest suppressed monsoon conditions, while simulated water vapor deposition to hydrometeors always exceeds sublimation on average at all TTL elevations over 24-hour timescales. The next largest water vapor budget term is generally the nudging required to keep domain averages consistent with observations, which is at least partly attributable to large-scale forcing terms that cannot be derived from measurements. We discuss the primary uncertainties.

  4. INTERCOMPARISON STUDY OF ATMOSPHERIC MERCURY MODELS: 1. COMPARISON OF MODELS WITH SHORT-TERM MEASUREMENTS

    EPA Science Inventory

    Five regional scale models with a horizontal domain covering the European continent and its surrounding seas, one hemispheric and one global scale model participated in an atmospheric mercury modelling intercomparison study. Model-predicted concentrations in ambient air were comp...

  5. Estimating near-road pollutant dispersion: a model inter-comparison

    EPA Science Inventory

    A model inter-comparison study to assess the abilities of steady-state Gaussian dispersion models to capture near-road pollutant dispersion has been carried out with four models (AERMOD, run with both the area-source and volume-source options to represent roadways, CALINE, versio...

  6. International intercomparison of measuring instruments for radon/thoron gas and radon short-lived daughter products in the NRPI Prague.

    PubMed

    Jílek, K; Hýža, M; Kotík, L; Thomas, J; Tomášek, L

    2014-07-01

    During the 7th European Conference on Protection Against Radon at Home and at Work held in the autumn of 2013 in Prague, the second intercomparison of measuring instruments for radon and its short-lived decay products and the first intercomparison of radon/thoron gas discriminative passive detectors in mix field of radon/thoron were organised by and held at the Natural Radiation Division of the National Radiation Protection Institute (NRPI) in Prague. In total, 14 laboratories from 11 different countries took part in the 2013 NRPI intercomparison. They submitted both continuous monitors for the measurement of radon gas and equivalent equilibrium radon concentration in a big NRPI chamber (48 m3) and sets of passive detectors including radon/thoron discriminative for the measurement of radon gas in the big chamber and thoron gas in a small thoron chamber (150 dm3). © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Operational overview of the NASA GTE/CITE 3 airborne instrument intercomparisons for sulfur dioxide, hydrogen sulfide, carbonyl sulfide, dimethyl sulfide, and carbon disulfide

    NASA Technical Reports Server (NTRS)

    Hoell, James M., Jr.; Davis, Douglas D.; Gregory, Gerald L.; Mcneal, Robert J.; Bendura, Richard J.; Drewry, Joseph W.; Barrick, John D.; Kirchhoff, Volker W. J. H.; Motta, Adauto G.; Navarro, Roger L.

    1993-01-01

    This paper reports the overall experimental design and gives a brief overview of results from the third airborne Chemical Instrumentation Test and Evaluation (CITE 3) mission conducted as part of the National Aeronautics and Space Administration's Global Tropospheric Experiment. The primary objective of CITE 3 was to evaluate the capability of instrumentation for airborne measurements of ambient concentrations of SO2, H2S, CS, dimethyl sulfide, and carbonyl sulfide. Ancillary measurements augmented the intercomparison data in order to address the secondary objective of CITE 3 which was to address specific issues related to the budget and photochemistry of tropospheric sulfur species. The CITE 3 mission was conducted on NASA's Wallops Flight Center Electra aircraft and included a ground-based intercomparison of sulfur standards and intercomparison/sulfur science flights conducted from the NASA Wallops Flight Facility, Wallops Island, Virginia, followed by flights from Natal, Brazil. Including the transit flights, CITE 3 included 16 flights encompassing approximately 96 flight hours.

  8. A soil sampling intercomparison exercise for the ALMERA network.

    PubMed

    Belli, Maria; de Zorzi, Paolo; Sansone, Umberto; Shakhashiro, Abduhlghani; Gondin da Fonseca, Adelaide; Trinkl, Alexander; Benesch, Thomas

    2009-11-01

    Soil sampling and analysis for radionuclides after an accidental or routine release is a key factor for the dose calculation to members of the public, and for the establishment of possible countermeasures. The IAEA organized for selected laboratories of the ALMERA (Analytical Laboratories for the Measurement of Environmental Radioactivity) network a Soil Sampling Intercomparison Exercise (IAEA/SIE/01) with the objective of comparing soil sampling procedures used by different laboratories. The ALMERA network is a world-wide network of analytical laboratories located in IAEA member states capable of providing reliable and timely analysis of environmental samples in the event of an accidental or intentional release of radioactivity. Ten ALMERA laboratories were selected to participate in the sampling exercise. The soil sampling intercomparison exercise took place in November 2005 in an agricultural area qualified as a "reference site", aimed at assessing the uncertainties associated with soil sampling in agricultural, semi-natural, urban and contaminated environments and suitable for performing sampling intercomparison. In this paper, the laboratories sampling performance were evaluated.

  9. Climate model simulations of the mid-Pliocene: Earth's last great interval of global warmth

    USGS Publications Warehouse

    Dolan, A.M.; Haywood, A.M.; Dowsett, H.J.

    2012-01-01

    Pliocene Model Intercomparison Project Workshop; Reston, Virginia, 2–4 August 2011 The Pliocene Model Intercomparison Project (PlioMIP), supported by the U.S. Geological Survey's (USGS) Pliocene Research, Interpretation and Synoptic Mapping (PRISM) project and Powell Center, is an integral part of a third iteration of the Paleoclimate Modelling Intercomparison Project (PMIP3). PlioMIP's aim is to systematically compare structurally different climate models. This is done in the context of the mid-Pliocene (~3.3–3.0 million years ago), a geological interval when the global annual mean temperature was similar to predictions for the next century.

  10. Association of hyperfunctioning thyroid adenoma with thyroid cancer presenting as "trapping only" nodule at 99mTcO4- scintigraphy.

    PubMed

    dell'Erba, L; Gerundini, P; Caputo, M; Bagnasco, M

    2003-11-01

    Rarely may a non-hyperfunctioning thyroid nodule present as "hot" at Technetium-99m pertechnetate (99mTcO4-) and "cold" at radioiodine scintigraphy at late acquisitions. We report the case of a hyperthyroid female patient whose 99mTcO4- scintigraphy showed two "hot" nodules, whereas Iodide-131 (131I-) revealed a lack of indicator uptake by the larger, and intense uptake by the smaller nodule. The patient underwent surgery: histology demonstrated that the larger nodule, mismatched at pertechnetate vs iodine scintigraphy, was a papillary carcinoma. Our suggestion is to perform thyroid scintigraphy with radioiodine in hyperthyroid patients with more than one nodule concentrating pertechnetate, especially when an ultrasonographic pattern possibly suspect for malignancy is present.

  11. [Management of hypothyroidism and hyperthyroidism].

    PubMed

    Jiskra, Jan

    2015-10-01

    Functional thyropathies present significant health risks for patients. Advanced functional thyropathies are always treated while indications for therapy of subclinical thyropathies are individual and often controversial. It is widely agreed that these disorders should be diagnosed and individuals should be followed. The drug of choice in substitution therapy of hypothyroidism is levothyroxine, in the treatment of hyperthyroidism it is methimazole. Administration of propylthiouracil should be limited to the first trimester of pregnancy, because its serious hepatotoxicity has been described. Hyperthyroidism based on thyroid nodules and immunogenic hyperthyroidism not reaching long-term remission, need to be treated radically: by surgery or radioiodine treatment. When radiation protection requirements are met, radioiodine can also be administered on an outpatient basis. Exceptionally, small doses of methimazole can be administered over an extended period of time in individual cases.

  12. THE NORTH AMERICAN MERCURY MODEL INTER-COMPARISON STUDY (NAMMIS)

    EPA Science Inventory

    This paper describes the North American Mercury Model Inter-comparison Study (NAMMIS). The NAMMIS is an effort to apply atmospheric Hg models in a tightly constrained testing environment with a focus on North America. With each model using the same input data sets for initial co...

  13. SimilarityExplorer: A visual inter-comparison tool for multifaceted climate data

    Treesearch

    J. Poco; A. Dasgupta; Y. Wei; W. Hargrove; C. Schwalm; R. Cook; E. Bertini; C. Silva

    2014-01-01

    Inter-comparison and similarity analysis to gauge consensus among multiple simulation models is a critical visualization problem for understanding climate change patterns. Climate models, specifically, Terrestrial Biosphere Models (TBM) represent time and space variable ecosystem processes, for example, simulations of photosynthesis and respiration, using algorithms...

  14. FIELD INTERCOMPARISON OF SULFATE DRY DEPOSITION MONITORING AND MEASUREMENT METHODS: PRELIMINARY RESULTS

    EPA Science Inventory

    The Illinois State Water Survey hosted a three-week field intercomparison of several sulfate dry deposition measurement techniques during September 81. The site was an 80-acre grass field in a rural area 14 km southwest of Champaign, IL. The vegetation consisted of mixed grasses ...

  15. An Analysis of Simulated Wet Deposition of Mercury from the North American Mercury Model Intercomparison Study

    EPA Science Inventory

    A previous intercomparison of atmospheric mercury models in North America has been extended to compare simulated and observed wet deposition of mercury. Three regional-scale atmospheric mercury models were tested; CMAQ, REMSAD and TEAM. These models were each employed using thr...

  16. METHODS INTERCOMPARISON OF SAMPLERS FOR EPA'S NATIONAL PM 2.5 CHEMICAL SPECIATION NETWORK

    EPA Science Inventory

    The objective of this sampler intercomparison field study is to determine the performance characteristics for the collection of the chemical components of PM2.5 by the chemical speciation monitors developed for the national PM2.5 network relative to each other, to the Federal R...

  17. Solid precipitation measurement intercomparison in Bismarck, North Dakota, from 1988 through 1997

    USGS Publications Warehouse

    Ryberg, Karen R.; Emerson, Douglas G.; Macek-Rowland, Kathleen M.

    2009-01-01

    A solid precipitation measurement intercomparison was recommended by the World Meteorological Organization (WMO) and was initiated after approval by the ninth session of the Commission for Instruments and Methods of Observation. The goal of the intercomparison was to assess national methods of measuring solid precipitation against methods whose accuracy and reliability were known. A field study was started in Bismarck, N. Dak., during the 1988-89 winter as part of the intercomparison. The last official field season of the WMO intercomparison was 1992-93; however, the Bismarck site continued to operate through the winter of 1996-97. Precipitation events at Bismarck were categorized as snow, mixed, or rain on the basis of descriptive notes recorded as part of the solid precipitation intercomparison. The rain events were not further analyzed in this study. Catch ratios (CRs) - the ratio of the precipitation catch at each gage to the true precipitation measurement (the corrected double fence intercomparison reference) - were calculated. Then, regression analysis was used to develop equations that model the snow and mixed precipitation CRs at each gage as functions of wind speed and temperature. Wind speed at the gages, functions of temperature, and upper air conditions (wind speed and air temperature at 700 millibars pressure) were used as possible explanatory variables in the multiple regression analysis done for this study. The CRs were modeled by using multiple regression analysis for the Tretyakov gage, national shielded gage, national unshielded gage, AeroChem gage, national gage with double fence, and national gage with Wyoming windshield. As in earlier studies by the WMO, wind speed and air temperature were found to influence the CR of the Tretyakov gage. However, in this study, the temperature variable represented the average upper air temperature over the duration of the event. The WMO did not use upper air conditions in its analysis. The national shielded and unshielded gages where found to be influenced by functions of wind speed only, as in other studies, but the upper air wind speed was used as an explanatory variable in this study. The AeroChem gage was not used in the WMO intercomparison study for 1987-93. The AeroChem gage had a highly varied CR at Bismarck, and a number of variables related to wind speed and temperature were used in the model for the CR. Despite extensive efforts to find a model for the national gage with double fence, no statistically significant regression model was found at the 0.05 level of statistical significance. The national gage with Wyoming windshield had a CR modeled by temperature and wind speed variables, and the regression relation had the highest coefficient of determination (R2 = 0.572) and adjusted coefficient of multiple determination (R2a = 0.476) of all of the models identified for any gage. Three of the gage CRs evaluated could be compared with those in the WMO intercomparison study for 1987-93. The WMO intercomparison had the advantage of a much larger dataset than this study. However, the data in this study represented a longer time period. Snow precipitation catch is highly varied depending on the equipment used and the weather conditions. Much of the variation is not accounted for in the WMO equations or in the equations developed in this study, particularly for unshielded gages. Extensive attempts at regression analysis were made with the mixed precipitation data, but it was concluded that the sample sizes were not large enough to model the CRs. However, the data could be used to test the WMO intercomparison equations. The mixed precipitation equations for the Tretyakov and national shielded gages are similar to those for snow in that they are more likely to underestimate precipitation when observed amounts were small and overestimate precipitation when observed amounts were relatively large. Mixed precipitation is underestimated by the WMO adjustment and t

  18. Recombinant human thyrotropin stimulation prior to 131I therapy in toxic multinodular goitre with low radioactive iodine uptake.

    PubMed

    Azorín Belda, M J; Martínez Caballero, A; Figueroa Ardila, G C; Martínez Ramírez, M; Gómez Jaramillo, C A; Dolado Ardit, J I; Verdú Rico, J

    Stimulation with recombinant human thyrotropin (rhTSH) increases thyroid radioiodine uptake, and is an aid to 131 I therapy in non-toxic multinodular goitre (MNG). However, there are not many studies using rhTSH prior to 131 I in toxic multinodular goitre to improve hyperthyroidism and compressive symptoms. A prospective study was conducted on patients with MNG and hyperthyroidism. Patients were recruited consecutively and divided into group I, stimulated with 0.3mg of rhTSH before radioiodine therapy, and a control group or group II, without stimulation. Thyroid function, radioiodine thyroid uptake, thyroid weight, and compressive symptoms were measured, and patients were followed-up for 9 months. Group I consisted of 16 patients (14 women), with a mean age 69.7 years, and group II with 16 patients (12 women), with a mean age 70.7 years. After stimulation with 0.3mg rhTSH in group I, 131 I uptake (RAIU) at 24h increased by 78.4%, and the estimated absorbed dose by 89.3%. In group II, the estimated absorbed dose was lower than group I after stimulation with rhTSH (29.8Gy vs. 56.4Gy; P=0.001). At 9 months of follow-up, hyperthyroidism was controlled in 87.5% of patients in group I, and 56.2% in group II (P=0.049). The mean reduction in thyroid weight was higher in group I than in group II (39.3% vs. 26.9%; P=0.017), with a tendency towards subjective improvement of compressive symptoms in group I, although non-significant. Only 2 patients described tachycardias after rhTSH administration, which were resolved with beta-blockers. Stimulation with 0.3mg of recombinant human thyrotropin prior to radioiodine therapy achieves a reduction in thyroid weight and functional improvement in patients with hyperthyroidism and multinodular goitre with low uptake, and with no need for hospital admission. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  19. Radioiodine: the classic theranostic agent.

    PubMed

    Silberstein, Edward B

    2012-05-01

    Radioiodine has the distinction of being the first theranostic agent in our armamentarium. Millennia were required to discover that the agent in orally administered seaweed and its extracts, which had been shown to cure neck swelling due to thyromegaly, was iodine, first demonstrated to be a new element in 1813. Treatment of goiter with iodine began at once, but its prophylactic value to prevent a common form of goiter took another century. After Enrico Fermi produced the first radioiodine, (128)I, in 1934, active experimentation in the United States and France delineated the crucial role of iodine in thyroid metabolism and disease. (130)I and (131)I were first employed to treat thyrotoxicosis by 1941, and thyroid cancer in 1943. After World War II, (131)I became widely available at a reasonable price for diagnostic testing and therapy. The rectilinear scanner of Cassen and Curtis (Science 1949;110:94-95), and a dedicated gamma camera invented by Anger (Nature 1952;170:200-201), finally permitted the diagnostic imaging of thyroid disease, with (131)I again the radioisotope of choice, although there were short-lived attempts to employ (125)I and (132)I for this purpose. (123)I was first produced in 1949 but did not become widely available until about 1982, 10 years after a production technique eliminated high-energy (124)I contamination. I continues to be the radioiodine of choice for the diagnosis of benign thyroid disease, whereas (123)I and (131)I are employed in the staging and detection of functioning thyroid cancer. (124)I, a positron emitter, can produce excellent anatomically correlated images employing positron emission tomography/computed tomography equipment and has the potential to enhance heretofore imperfect dosimetric studies in determining the appropriate administered activity to ablate/treat thyroid cancer. Issues of acceptable measuring error in thyroid cancer dosimetry and the role in (131)I therapy of tumor heterogeneity, tumor hypoxia, and kinetics must be overcome, and long-term outcome studies following (131)I given based on this new dosimetry must be completed before the nuclear medicine community will be able to predictably cure our thyroid cancer patients with this technology. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. The Role of Radiopharmaceuticals in Amiodarone-Induced Thyroid Pathology.

    PubMed

    Irimie, Alexandru; Piciu, Doina

    2017-11-10

    The use of amiodarone for the treatment of ventricular and supraventricular dysrhythmias brings in organism an increased amount of iodine, interfering with thyroid function. If the treatment needs to be interrupted, iodine remains at abnormal levels for months or even years. The aim of the study was to review the literature regarding the optimal tests for early diagnostic and to analyze the role of nuclear medicine tests in the differential and correct assessment of the amiodarone-induced thyroid pathology. We made a review of available publications in PUBMED referring the amiodaroneinduced thyroid pathology, focusing on the differential diagnosis, made by nuclear medicine tests, of hypothyroidism (AIH) and hyperthyroidism expressed as: type I amiodarone induced thyrotoxicosis (AIT I), type II amiodarone induced thyrotoxicosis (AIT II), and less frequently as a mixt form, type III amiodarone induced thyrotoxicosis (AIT III). We presented cases from the database of a tertiary center in Cluj-Napoca, Romania. Despite the frequent complication of thyroid function, this pathology is underestimated and diagnosed. There is a limited number of studies and clear protocols, especially in the mixed forms cases. This increase in iodine uptake interferes seriously with thyroid hormone production and release. The nuclear medicine tests are essential in the correct assessment and differential diagnosis of different forms of induced thyroid dysfunction. The destruction of the follicular cells can result in the release of excessive thyroid hormone into the circulation, with potential development of atrial fibrillation, worsening the cardiac disease, so any benefic therapeutic procedure should be known; the use of radioiodine as therapy alternative, despite the known limitations induced by blockade was clear benefic in the case presented. A special attention needs to be addressed to those patients with differentiated thyroid cancer, which will be submitted to radioiodine therapy and are under chronic therapy with amiodarone. The nuclear medicine procedures are essential in the correct assessment and differential diagnosis of different forms of induced thyroid dysfunction. The radioiodine is not recommended in AIT, due to stunning effect induced by iodine excess, but in some special, lifethreatening condition, radioiodine I-131 might be a treatment option. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  1. Iodine distribution in natural waters of different chemical composition in relation to water-bearing soils and rocks and water fractions in areas subjected to radioiodine contamination

    NASA Astrophysics Data System (ADS)

    Kolmykova, Liudmila; Korobova, Elena

    2017-04-01

    Iodine is an essential microelement required for normal functioning of thyroid gland. Natural deficiency of stable iodine is compensated by its active intake by thyroid and provokes its higher irradiation in case of radiation accidents and contamination of the environment by radioiodine isotopes. The bioavailability of both stable and radioactive iodine and the specificity of its uptake by living organisms largely depends on geochemical parameters of the environment related to natural conditions of water migration. The goal of the study was to investigate spatial distribution of iodine in natural water of different chemical composition in relation to typical water-bearing soils and rocks and water fractions in Bryansk areas subjected to radioiodine contamination after the Chernobyl accident and to evaluate contribution of this factor to the occurrence of endemic thyroid diseases among local population inhabiting geochemically different areas of fluvioglacial and loess-like sedimentary rocks. The highest content of iodine (Me=13.3 µg/l) was observed in surface water of landscapes with H-Ca, Ca and H-Ca-Fe classes of water migration. The lowest microelement level (Me=5.25 µg/l) was noted in groundwater of landscapes with H, H-Fe classes of water migration in areas of Paleogene water bearing rocks. Regardless of the type of source and class of water migration up to 90% of the total content of iodide is present in the fraction <0.45 µm (as determined by membrane filtration). Up to 50% of iodine pass to solution containing particles < 0.1 µm and increases up to 80% in absence of roughly dispersed sorbents in this fraction. The surface water in areas of loess-like sedimentary rocks hosts the highest levels of iodine where its associated with calcium mineral aquatic complexes and the suspended particles. The obtained data is believed to be useful in explanation of mobility and intake of iodine and its radioactive analogues by rural population living in different geochemical conditions and using local drinking waters. The data should be accounted of in planning prophylactics of endemic diseases and counter measures in case of radioiodine fallout.

  2. Chemical composition of drinking water as a possible environment-specific factor modifying the thyroid risk in the areas subjected to radioiodine contamination

    NASA Astrophysics Data System (ADS)

    Kolmykova, Lyudmila; Korobova, Elena; Ryzhenko, Boris

    2015-04-01

    Water is one of the main natural agents providing chemical elements' migration in the environment and food chains. In our opinion a study of spatial variation of the essential trace elements in local drinking water is worth considering as the factor that may contribute to variation of the health risk in areas contaminated by radionuclides and radioiodine in particular. Radioiodine was proved to increase the risk of thyroid cancer among children who lived in areas contaminated during the Chernobyl accident. It was also shown that low stable iodine status of the contaminated area and population also contributed to the risk of this disease in case of radionuclide contamination. The goal of the study was to investigate chemical composition of the drinking water in rural settlements of the Bryansk oblast' subjected to radioiodine contamination and to evaluate speciation of stable I and Se on the basis of their total concentration and chemical composition of the real water samples with the help of thermodynamic modelling. Water samples were collected from different aquifers discharging at different depths (dug wells, local private bore holes and water pipes) in rural settlements located in areas with contrasting soil iodine status. Thermodynamic modelling was performed using original software (HCh code of Y.Shvarov, Moscow State University, RUSSIA) incorporating the measured pH, Corg and elements' concentration values. Performed modelling showed possibility of formation of complex CaI+ ion in aqueous phase, I sorption by goethite and transfer of Se to solid phase as FeSe in the observed pH-Eh conditions. It helped to identify environmental conditions providing high I and Se mobility and their depletion from natural waters. Both the experimental data and modeling showed that I and Se migration and deficiency in natural water is closely connected to pH, Eh conditions and the concentration of typomorphic chemical elements (Ca, Mg, Fe) defining the class of water migration in landscapes (according Perel'man, 1975). Obtained data will be used for evaluation of contribution of I and Se status of drinking water to the risk of thyroid diseases among local population.

  3. The management of metastatic radioiodine-refractory differentiated thyroid cancer requires an integrated approach including both directed and systemic therapies.

    PubMed

    Cooray, Shamil D; Topliss, Duncan J

    2017-01-01

    A 58-year-old man with metastatic radioiodine-refractory differentiated thyroid cancer (DTC) presented with left thigh and right flank numbness. He had known progressive and widespread bony metastases, for which he received palliative radiotherapy, and multiple bilateral asymptomatic pulmonary metastases. CT scan and MRI of the spine revealed metastases at right T10-L1 vertebrae with extension into the central canal and epidural disease at T10 and T11 causing cord displacement and canal stenosis but retention of spinal cord signal. Spinal surgery was followed by palliative radiotherapy resulting in symptom resolution. Two months later, sorafenib received approval for use in Australia and was commenced and up-titrated with symptomatic management of mild adverse effects. Follow-up CT scan three months after commencement of sorafenib revealed regression of pulmonary metastases but no evident change in most bone metastases except for an advancing lesion eroding into the right acetabulum. The patient underwent a right total hip replacement, intra-lesional curettage and cementing. After six months of sorafenib therapy, CT scanning showed enlarging liver lesions with marked elevation of serum thyroglobulin. Lenvatinib was commenced and sorafenib was ceased. He now has stable disease with a falling thyroglobulin more than 5 years after metastatic radioiodine-refractory DTC was diagnosed. In DTC, 5% of distant metastases become radioiodine-refractory, resulting in a median overall survival of 2.5-3.5 years. Tyrosine kinase inhibitor (TKI) therapy has recently been demonstrated to increase progression-free survival in these patients but poses some unique management issues and is best used as part of an integrated approach with directed therapy. Directed therapies may have greater potential to control localised disease and related symptoms when compared to systemic therapies.Consider TKI therapy in progressive disease where benefits outweigh risks.Active surveillance and timely intervention are required for TKI-related adverse effects.There is a need for further research on the clinical application of TKI therapy in advanced DTC, including comparative efficacy, sequencing and identifying responders.

  4. Middle Atmosphere Program. Handbook for MAP, volume 28

    NASA Technical Reports Server (NTRS)

    Liu, C. H. (Editor); Edwards, Belva (Editor)

    1989-01-01

    Extended abstracts from the fourth workshop on the technical and scientific aspects of MST (mesosphere stratosphere troposphere) radar are presented. Individual sessions addressed the following topics: meteorological applications of MST and ST radars, networks, and campaigns; dynamics of the equatorial middle atmosphere; interpretation of radar returns from clear air; techniques for studying gravity waves and turbulence; intercomparison and calibration of wind and wave measurements at various frequencies; progress in existing and planned MST and ST radars; hardware design for MST and ST radars and boundary layer/lower troposphere profilers; signal processing; and data management.

  5. High Resolution Model Intercomparison Project (HighResMIP v1.0) for CMIP6

    NASA Astrophysics Data System (ADS)

    Haarsma, Reindert J.; Roberts, Malcolm J.; Vidale, Pier Luigi; Senior, Catherine A.; Bellucci, Alessio; Bao, Qing; Chang, Ping; Corti, Susanna; Fučkar, Neven S.; Guemas, Virginie; von Hardenberg, Jost; Hazeleger, Wilco; Kodama, Chihiro; Koenigk, Torben; Leung, L. Ruby; Lu, Jian; Luo, Jing-Jia; Mao, Jiafu; Mizielinski, Matthew S.; Mizuta, Ryo; Nobre, Paulo; Satoh, Masaki; Scoccimarro, Enrico; Semmler, Tido; Small, Justin; von Storch, Jin-Song

    2016-11-01

    Robust projections and predictions of climate variability and change, particularly at regional scales, rely on the driving processes being represented with fidelity in model simulations. The role of enhanced horizontal resolution in improved process representation in all components of the climate system is of growing interest, particularly as some recent simulations suggest both the possibility of significant changes in large-scale aspects of circulation as well as improvements in small-scale processes and extremes. However, such high-resolution global simulations at climate timescales, with resolutions of at least 50 km in the atmosphere and 0.25° in the ocean, have been performed at relatively few research centres and generally without overall coordination, primarily due to their computational cost. Assessing the robustness of the response of simulated climate to model resolution requires a large multi-model ensemble using a coordinated set of experiments. The Coupled Model Intercomparison Project 6 (CMIP6) is the ideal framework within which to conduct such a study, due to the strong link to models being developed for the CMIP DECK experiments and other model intercomparison projects (MIPs). Increases in high-performance computing (HPC) resources, as well as the revised experimental design for CMIP6, now enable a detailed investigation of the impact of increased resolution up to synoptic weather scales on the simulated mean climate and its variability. The High Resolution Model Intercomparison Project (HighResMIP) presented in this paper applies, for the first time, a multi-model approach to the systematic investigation of the impact of horizontal resolution. A coordinated set of experiments has been designed to assess both a standard and an enhanced horizontal-resolution simulation in the atmosphere and ocean. The set of HighResMIP experiments is divided into three tiers consisting of atmosphere-only and coupled runs and spanning the period 1950-2050, with the possibility of extending to 2100, together with some additional targeted experiments. This paper describes the experimental set-up of HighResMIP, the analysis plan, the connection with the other CMIP6 endorsed MIPs, as well as the DECK and CMIP6 historical simulations. HighResMIP thereby focuses on one of the CMIP6 broad questions, "what are the origins and consequences of systematic model biases?", but we also discuss how it addresses the World Climate Research Program (WCRP) grand challenges.

  6. The Fifth Calibration/Data Product Validation Panel Meeting

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The minutes and associated documents prepared from presentations and meetings at the Fifth Calibration/Data Product Validation Panel meeting in Boulder, Colorado, April 8 - 10, 1992, are presented. Key issues include (1) statistical characterization of data sets: finding statistics that characterize key attributes of the data sets, and defining ways to characterize the comparisons among data sets; (2) selection of specific intercomparison exercises: selecting characteristic spatial and temporal regions for intercomparisons, and impact of validation exercises on the logistics of current and planned field campaigns and model runs; and (3) preparation of data sets for intercomparisons: characterization of assumptions, transportable data formats, labeling data files, content of data sets, and data storage and distribution (EOSDIS interface).

  7. INTERCOMPARISON STUDY OF ATMOSPHERIC MERCURY MODELS: 2. MODELING RESULTS VS. LONG-TERM OBSERVATIONS AND COMPARISON OF COUNTRY ATMOSPHERIC BALANCES

    EPA Science Inventory

    Five regional scale models with a horizontal domain covering the European continent and its surrounding seas, two hemispheric and one global scale model participated in the atmospheric Hg modelling intercomparison study. The models were compared between each other and with availa...

  8. A Compendium on the NIST Radionuclidic Assays of the Massic Activity of 63Ni and 55Fe Solutions Used for an International Intercomparison of Liquid Scintillation Spectrometry Techniques

    PubMed Central

    Collé, R.; Zimmerman, B. E.

    1997-01-01

    The National Institute of Standards and Technology recently participated in an international measurement intercomparison for 63Ni and 55Fe, which was conducted amongst principal national radionuclidic metrology laboratories. The intercomparison was sponsored by EUROMET, and was primarily intended to evaluate the capabilities of liquid scintillation (LS) spectrometry techniques for standardizing nuclides that decay by low-energy β-emission (like 63Ni) and by low-Z (atomic number) electron capture (like 55Fe). The intercomparison findings exhibit a very good agreement for 63Ni amongst the various participating laboratories, including that for NIST, which suggests that the presently invoked LS methodologies are very capable of providing internationally-compatible standardizations for low-energy β-emitters. The results for 55Fe are in considerably poorer agreement, and demonstrated the existence of several unresolved problems. It has thus become apparent that there is a need for the various international laboratories to conduct rigorous, systematic evaluations of their LS capabilities in assaying radionuclides that decay by low-Z electron capture. PMID:27805141

  9. SECOND LATIN AMERICAN INTERCOMPARISON ON INTERNAL DOSE ASSESSMENT.

    PubMed

    Rojo, A; Puerta, N; Gossio, S; Gómez Parada, I; Cruz Suarez, R; López, E; Medina, C; Lastra Boylan, J; Pinheiro Ramos, M; Mora Ramírez, E; Alves Dos Reis, A; Yánez, H; Rubio, J; Vironneau Janicek, L; Somarriba Vanegas, F; Puerta Ortiz, J; Salas Ramírez, M; López Bejerano, G; da Silva, T; Miri Oliveira, C; Terán, M; Alfaro, M; García, T; Angeles, A; Duré Romero, E; Farias de Lima, F

    2016-09-01

    Internal dosimetry intercomparisons are essential for the verification of applied models and the consistency of results'. To that aim, the First Regional Intercomparison was organised in 2005, and that results led to the Second Regional Intercomparison Exercise in 2013, which was organised in the frame of the RLA 9/066 and coordinated by Autoridad Regulatoria Nuclear of Argentina. Four simulated cases covering intakes of (131)I, (137)Cs and Tritium were proposed. Ninteen centres from thirteen different countries participated in this exercise. This paper analyses the participants' results in this second exercise in order to test their skills and acquired knowledge, particularly in the application of the IDEAS Guidelines. It is important to highlight the increased number of countries that participated in this exercise compared with the first one and, furthermore, the improvement in the overall performance. The impact of the International Atomic Energy Agency (IAEA) Projects since 2003 has led to a significant enhancement of internal dosimetry capabilities that strengthen the radiation protection of workers. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. 1993 Intercomparison of Photometric Units Maintained at NIST (USA) and PTB (Germany)

    PubMed Central

    Ohno, Yoshihiro; Sauter, Georg

    1995-01-01

    A bilateral intercomparison of photometric units between NIST, USA and PTB, Germany has been conducted to update the knowledge of the relationship between the photometric units disseminated in each country. The luminous intensity unit (cd) and the luminous flux unit (lm) maintained at both laboratories are compared by circulating transfer standard lamps. Also, the photometric responsivity sv is compared by circulating a V(λ)-corrected detector with a built-in current-to-voltage converter. The results show that the difference of luminous intensity unit between NIST and PTB, (PTB-NIST)/NIST, is 0.2 % with a relative expanded uncertainty (coverage factor k = 2) of 0.24 %. The difference is reduced significantly from that at the 1985 CCPR intercomparison (0.9 %). The difference in luminous flux unit, (PTB – NIST)/NIST, is found to be 1.5 % with a relative expanded uncertainty (coverage factor k =2) of 0.15 %. The difference remained nearly the same as that at the 1985 intercomparison (1.6 %). These results agree with what is predicted from the history of maintaining the units at each laboratory. PMID:29151737

  11. [Radioiodine treatment of Graves' disease --for its wider indication and application in Japan].

    PubMed

    Konishi, Junji

    2006-12-01

    Radioiodine treatment has been well established as an effective and safe therapeutic modality for Graves' disease. To promote more efficient use of this treatment in Japan, a working group has been organized in the Japan Thyroid Association and preparation of guidelines for its clinical use is under way. The treatment using upto 13.5 mCi of I-131 is feasible on out-patient basis. In comparison to the antithyroid drug treatment, the treatment has no side effects, brings in good control of hyperthyroidism and decrease the size of goiter. It is contraindicated in pregnant and lactating women. Patients treated should be carefully monitored for the possible worsening of ophthalmopathy and neonatal Graves' disease. Recent studies revealed the cost-effectiveness of the treatment. Its application to autonomously functioning thyroid nodules and toxic multinodular goiters is also discussed.

  12. A convenient Simple Method for Synthesis of Meta-iodobenzylguanidine (MIBG).

    PubMed

    Sheikholislam, Zahra; Soleimani, Zohreh; Moghimi, Abolghasem; Shahhosseini, Soraya

    2013-01-01

    Radioiodinated meta-iodobenzylguanidine (MIBG) is one of the important radiopharmaceuticals in Nuclear Medicine. [(123/131)I] MIBG is used for imaging of Adrenal medulla, studying heart sympathetic nerves, treatment of pheochromacytoma and neuroblastoma. For clinical application, radioiodinated MIBG is prepared through isotopic exchange method, which includes replacement of radioactive iodine in a nucleophilic substitution reaction with cold iodine ((127)I). The unlabelled MIBG hemisulfate is synthesized by the procedure described by Wieland et al. (1980). The availability of a more practical and cost-effective procedure for MIBG preparation encouraged us to study the MIBG synthesis methods. In this study the preparation of MIBG through different methods were evaluated and a new method, which is one step, simple and cost-effective is introduced. The method has ability to be scaled up for production of unlabelled MIBG.

  13. (125)I-Tetrazines and Inverse-Electron-Demand Diels-Alder Chemistry: A Convenient Radioiodination Strategy for Biomolecule Labeling, Screening, and Biodistribution Studies.

    PubMed

    Albu, Silvia A; Al-Karmi, Salma A; Vito, Alyssa; Dzandzi, James P K; Zlitni, Aimen; Beckford-Vera, Denis; Blacker, Megan; Janzen, Nancy; Patel, Ramesh M; Capretta, Alfredo; Valliant, John F

    2016-01-20

    A convenient method to prepare radioiodinated tetrazines was developed, such that a bioorthogonal inverse electron demand Diels-Alder reaction can be used to label biomolecules with iodine-125 for in vitro screening and in vivo biodistribution studies. The tetrazine was prepared by employing a high-yielding oxidative halo destannylation reaction that concomitantly oxidized the dihydrotetrazine precursor. The product reacts quickly and efficiently with trans-cyclooctene derivatives. Utility was demonstrated through antibody and hormone labeling experiments and by evaluating products using standard analytical methods, in vitro assays, and quantitative biodistribution studies where the latter was performed in direct comparison to Bolton-Hunter and direct iodination methods. The approach described provides a convenient and advantageous alternative to conventional protein iodination methods that can expedite preclinical development and evaluation of biotherapeutics.

  14. Effect of specific activity on cardiac uptake of iodine-123-MIBG.

    PubMed

    Farahati, J; Bier, D; Scheubeck, M; Lassmann, M; Schelper, L F; Grelle, I; Hanscheid, H; Biko, J; Graefe, K H; Reiners, C

    1997-03-01

    Radioiodinated meta-iodobenzylguanidine (MIBG), an analog of norepinephrine, has been used to assess myocardial sympathetic innervation. Recent in vivo studies predict enhanced cardiac uptake of this radiopharmaceutical with high specific activity. To clarify the effect of specific activity on cardiac uptake of radioiodinated MIBG, the distribution and kinetics of no-carrier-added [123I]MIBG (> or = 7.4 TBq/mumol) were compared with those of commercial [123I]MIBG (approximately 74 MBq/mumol) in three healthy volunteers by serial imaging and blood sampling. Higher specific activity result in higher uptake of radioiodinated MIBG in all volunteers in the heart (p < 0.05) and liver (p < 0.05) but not in the lung (p = 0.26). Due to rapid deiodination, a more pronounced accumulation of radioactivity was present in plasma after no-carrier-added MIBG than commercial [123I]MIBG, resulting in higher background and thyroid activity after administration of the former. Calculated heart-to-liver (p = 0.96) and heart-to-lung (p = 0.42) count ratios in all volunteers revealed no significant improvement in cardiac imaging with no-carrier-added [123I]MIBG compared to commercial [123I]MIBG. This study highlights the appreciably higher in vivo deiodination of no-carrier-added [123I]MIBG compared to commercial preparation of [123I]MIBG in humans. Cardiac images acquired with no-carrier-added [123I]MIBG do not seem to be superior to those obtained with commercial MIBG.

  15. Reproducibility in cyclostratigraphy: initiating an intercomparison project

    NASA Astrophysics Data System (ADS)

    Sinnesael, Matthias; De Vleeschouwer, David; Zeeden, Christian; Claeys, Philippe

    2017-04-01

    The study of astronomical climate forcing and the application of cyclostratigraphy have experienced a spectacular growth over the last decades. In the field of cyclostratigraphy a broad range in methodological approaches exist. However, comparative study between the different approaches is lacking. Different cases demand different approaches, but with the growing importance of the field, questions arise about reproducibility, uncertainties and standardization of results. The radioisotopic dating community, in particular, has done far-reaching efforts to improve reproducibility and intercomparison of radioisotopic dates and their errors. To satisfy this need in cyclostratigraphy, we initiate a comparable framework for the community. The aims are to investigate and quantify reproducibility of, and uncertainties related to cyclostratigraphic studies and to provide a platform to discuss the merits and pitfalls of different methodologies, and their applicabilities. With this poster, we ask the feedback from the community on how to design this comparative framework in a useful, meaningful and productive manner. In parallel, we would like to discuss how reproducibility should be tested and what uncertainties should stand for in cyclostratigraphy. On the other hand, we intend to trigger interest for a cyclostratigraphic intercomparison project. This intercomparison project would imply the analysis of artificial and genuine geological records by individual researchers. All participants would be free to determine their method of choice. However, a handful of criterions will be required for an outcome to be comparable. The different results would be compared (e.g. during a workshop or a special session), and the lessons learned from the comparison could potentially be reported in a review paper. The aim of an intercomparison project is not to rank the different methods according to their merits, but to get insight into which specific methods are most suitable for which specific problems, and obtain more information on different sources of uncertainty. As this intercomparison project should be supported by the broader cyclostratigraphic community, we open the floor for suggestions, ideas and practical remarks.

  16. Spectroradiometer Intercomparison and Impact on Characterizing Photovoltaic Device Performance: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habte, A.; Andreas, A.; Ottoson, L.

    2014-11-01

    Indoor and outdoor testing of photovoltaic (PV) device performance requires the use of solar simulators and natural solar radiation, respectively. This performance characterization requires accurate knowledge of spectral irradiance distribution that is incident on the devices. Spectroradiometers are used to measure the spectral distribution of solar simulators and solar radiation. On September 17, 2013, a global spectral irradiance intercomparison using spectroradiometers was organized by the Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL). This paper presents highlights of the results of this first intercomparison, which will help to decrease systematic inter-laboratory differences in the measurements ofmore » the outputs or efficiencies of PV devices and harmonize laboratory experimental procedures.« less

  17. BRDF Characterization and Calibration Inter-Comparison between Terra MODIS, Aqua MODIS, and S-NPP VIIRS

    NASA Technical Reports Server (NTRS)

    Chang, Tiejun; Xiong, Xiaoxiong (Jack); Angal, Amit; Wu, Aisheng

    2016-01-01

    The inter-comparison of reflective solar bands (RSB) between Terra MODIS, Aqua MODIS, and SNPP VIIRS is very important for assessment of each instrument's calibration and to identify calibration improvements. One of the limitations of using their ground observations for the assessment is a lack of the simultaneous nadir overpasses (SNOs) over selected pseudo-invariant targets. In addition, their measurements over a selected Earth view target have significant difference in solar and view angles, and these differences magnify the effects of Bidirectional Reflectance Distribution Function (BRDF). In this work, an inter-comparison technique using a semi-empirical BRDF model is developed for reflectance correction. BRDF characterization requires a broad coverage of solar and view angles in the measurements over selected pseudo-invariant targets. Reflectance measurements over Libya 1, 2, and 4 desert sites from both the Aqua and Terra MODIS are regressed to a BRDF model with an adjustable coefficient accounting for the calibration difference between the two instruments. The BRDF coefficients for three desert sites for MODIS bands 1 to 9 are derived and the wavelength dependencies are presented. The analysis and inter-comparison are for MODIS bands 1 to 9 and VIIRS moderate resolution radiometric bands (M bands) M1, M2, M4, M5, M7, M8, M10 and imaging bands (I bands) I1-I3. Results show that the ratios from different sites are in good agreement. The ratios between Terra and Aqua MODIS from year 2003 to 2014 are presented. The inter-comparison between MODIS and VIIRS are analyzed for year 2014.

  18. A Methodological Inter-Comparison of Gridded Meteorological Products

    NASA Astrophysics Data System (ADS)

    Newman, A. J.; Clark, M. P.; Longman, R. J.; Giambelluca, T. W.; Arnold, J.

    2017-12-01

    Here we present a gridded meteorology inter-comparison using the state of Hawaíi as a testbed. This inter-comparison is motivated by two general goals: 1) the broad user community of gridded observation based meteorological fields should be aware of inter-product differences and the reasons they exist, which allows users to make informed choices on product selection to best meet their specific application(s); 2) we want to demonstrate the utility of inter-comparisons to meet the first goal, yet highlight that they are limited to mostly generic statements regarding attribution of differences that limits our understanding of these complex algorithms and obscures future research directions. Hawaíi is a useful testbed because it is a meteorologically complex region with well-known spatial features that are tied to specific physical processes (e.g. the trade wind inversion). From a practical standpoint, there are now several monthly climatological and daily precipitation and temperature datasets available that are being used for impact modeling. General conclusions that have emerged are: 1) differences in input station data significantly influence product differences; 2) prediction of precipitation occurrence is crucial across multiple metrics; 3) derived temperature statistics (e.g. diurnal temperature range) may have large spatial differences across products; and 4) attribution of differences to methodological choices is difficult and may limit the outcomes of these inter-comparisons, particularly from a development viewpoint. Thus, we want to continue to move the community towards frameworks that allow for multiple options throughout the product generation chain and allow for more systematic testing.

  19. Fetal radiation dose estimates for I-131 sodium iodide in cases where conception occurs after administration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sparks, R.B.; Stabin, M.G.

    1999-01-01

    After administration of I-131 to the female patient, the possibility of radiation exposure of the embryo/fetus exists if the patient becomes pregnant while radioiodine remains in the body. Fetal radiation dose estimates for such cases were calculated. Doses were calculated for various maternal thyroid uptakes and time intervals between administration and conception, including euthyroid and hyperthyroid cases. The maximum fetal dose calculating was about 9.8E-03 mGy/MBq, which occurred with 100% maternal thyroid uptake and a 1 week interval between administration and conception. Placental crossover of the small amount of radioiodine remaining 90 days after conception was also considered. Such crossovermore » could result in an additional fetal dose of 9.8E-05 mGy/MBq and a maximum fetal thyroid self dose of 3.5E-04 mGy/MBq.« less

  20. Use of radiofrequency ablation in benign thyroid nodules: a literature review and updates.

    PubMed

    Wong, Kai-Pun; Lang, Brian Hung-Hin

    2013-01-01

    Successful thermal ablation using radiofrequency has been reported in various tumors including liver or kidney tumors. Nonsurgical minimally invasive ablative therapy such as radiofrequency ablation (RFA) has been reported to be a safe and efficient treatment option in managing symptomatic cold thyroid nodules or hyperfunctioning thyroid nodules. Pressure and cosmetic symptoms have been shown to be significantly improved both in the short and long terms after RFA. For hyperfunctioning thyroid nodules, RFA is indicated for whom surgery or radioiodine are not indicated or ineffective or for those who refuse surgery or radio-iodine. Improvement of thyroid function with decreased need for antithyroid medications has been reported. Complication rate is relatively low. By reviewing the current literature, we reported its efficacy and complications and compared the efficacy of RFA relative to other ablative options such as ethanol ablation and laser ablation.

  1. Use of Radiofrequency Ablation in Benign Thyroid Nodules: A Literature Review and Updates

    PubMed Central

    Wong, Kai-Pun; Lang, Brian Hung-Hin

    2013-01-01

    Successful thermal ablation using radiofrequency has been reported in various tumors including liver or kidney tumors. Nonsurgical minimally invasive ablative therapy such as radiofrequency ablation (RFA) has been reported to be a safe and efficient treatment option in managing symptomatic cold thyroid nodules or hyperfunctioning thyroid nodules. Pressure and cosmetic symptoms have been shown to be significantly improved both in the short and long terms after RFA. For hyperfunctioning thyroid nodules, RFA is indicated for whom surgery or radioiodine are not indicated or ineffective or for those who refuse surgery or radio-iodine. Improvement of thyroid function with decreased need for antithyroid medications has been reported. Complication rate is relatively low. By reviewing the current literature, we reported its efficacy and complications and compared the efficacy of RFA relative to other ablative options such as ethanol ablation and laser ablation. PMID:24298282

  2. Comparison of /sup 125/I-labeled and /sup 14/C-Labeled peptides of the major outer membrane protein of Chlamydia Trachomatis Strain L2/434 separated by high-performance liquid chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Judd, R.C.; Caldwell, H.D.

    1985-01-01

    The objective of this study was to determine if in-gel chloramine-T radioiodination adequately labels OM proteins to allow for accurate and precise structural comparison of these molecules. Therefore, intrinsically /sup 14/C-amino acid labeled proteins and /sup 125/I-labeled proteins were cleaved with two endopeptidic reagents and the peptide fragments separated by HPLC. A comparison of retention times of the fragments, as determined by differential radiation counting, thus indicated whether /sup 125/Ilabeling identified of all the peptide peaks seen in the /sup 14/Clabeled proteins. Results demonstrated that radioiodination yields complete and accurate information about the primary structure of outer membrane proteins. Inmore » addition, it permits the use of extremely small amounts of protein allowing for method optimization and multiple separations to insure reproducibility.« less

  3. Assessing the Application of Cloud-Shadow Atmospheric Correction Algorithm on HICO

    DTIC Science & Technology

    2014-05-01

    multiple times and intercompare the results to assess variability in the retrieved reflectance spectra. Retrieved chlorophyll values from this...intercomparison are similar and also agree well with the In situ chlorophyll measurements. 15. SUBJECT TERMS Atmospheric correction, cloud-shadow...reflectance spectra. Re- trieved chlorophyll values from this intercomparison are similar and also agree well with the in situ chlorophyll measurements

  4. Development of phantom and methodology for 3D and 4D dose intercomparisons for advanced lung radiotherapy

    NASA Astrophysics Data System (ADS)

    Caloz, Misael; Kafrouni, Marilyne; Leturgie, Quentin; Corde, Stéphanie; Downes, Simon; Lehmann, Joerg; Thwaites, David

    2015-01-01

    There are few reported intercomparisons or audits of combinations of advanced radiotherapy methods, particularly for 4D treatments. As part of an evaluation of the implementation of advanced radiotherapy technology, a phantom and associated methods, initially developed for in-house commissioning and QA of 4D lung treatments, has been developed further with the aim of using it for end-to-end dose intercomparison of 4D treatment planning and delivery. The respiratory thorax phantom can house moving inserts with variable speed (breathing rate) and motion amplitude. In one set-up mode it contains a small ion chamber for point dose measurements, or alternatively it can hold strips of radiochromic film to measure dose distributions. Initial pilot and feasibility measurements have been carried out in one hospital to thoroughly test the methods and procedures before using it more widely across a range of hospitals and treatment systems. Overall, the results show good agreement between measured and calculated doses and distributions, supporting the use of the phantom and methodology for multi-centre intercomparisons. However, before wider use, refinements of the method and analysis are currently underway particularly for the film measurements.

  5. A Comparison of Aircraft and Ground-Based Measurements at Mauna Loa Observatory, Hawaii, During GTE PEM-West and MLOPEX 2

    NASA Technical Reports Server (NTRS)

    Atlas, E.; Ridley, B.; Walega, J.; Greenberg, J.; Kok, G.; Staffelbach, T.; Schauffler, S.; Lind, J.; Huebler, G.; Norton, R.

    1996-01-01

    During October 19-20, 1991, one flight of the NASA Global Tropospheric Experiment (GTE) Pacific Exploratory Mission (PEM-West A) mission was conducted near Hawaii as an intercomparison with ground-based measurements of the Mauna Loa Observatory Photochemistry Experiment (MLOPEX 2) and the NOAA Climate Modeling and Diagnostics Laboratory (CMDL). Ozone, reactive nitrogen species, peroxides, hydrocarbons, and halogenated hydrocarbons were measured by investigators aboard the DC-8 aircraft and at the ground site. Lidar cross sections of ozone revealed a complex air mass structure near the island of Hawaii which was evidenced by large variation in some trace gas mixing ratios. This variation limited the time and spatial scales for direct measurement intercomparisons. Where differences occurred between measurements in the same air masses, the intercomparison suggested that biases for some trace gases was due to different calibration scales or, in some cases, instrumental or sampling biases. Relatively large uncertainties were associated with those trace gases present in the low parts per trillion by volume range. Trace gas correlations were used to expand the scope of the intercomparison to identify consistent trends between the different data sets.

  6. Intercomparison of Global Precipitation Products: The Third Precipitation Intercomparison Project (PIP-3)

    NASA Technical Reports Server (NTRS)

    Adler, Robert F.; Kidd, Christopher; Petty, Grant; Morrissey, Mark; Goodman, H. Michael; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A set of global, monthly rainfall products has been intercompared to understand the quality and utility of the estimates. The products include 25 observational (satellite-based), four model and two climatological products. The results of the intercomparison indicate a very large range (factor of two or three) of values when all products are considered. The range of values is reduced considerably when the set of observational products is limited to those considered quasi-standard. The model products do significantly poorer in the tropics, but are competitive with satellite-based fields in mid-latitudes over land. Over ocean, products are compared to frequency of precipitation from ship observations. The evaluation of the observational products point to merged data products (including rain gauge information) as providing the overall best results.

  7. Adequate thyroid-stimulating hormone levels after levothyroxine discontinuation in the follow-up of patients with well-differentiated thyroid carcinoma.

    PubMed

    Sánchez, Reyna; Espinosa-de-los-Monteros, Ana Laura; Mendoza, Victoria; Brea, Eduardo; Hernández, Irma; Sosa, Ernesto; Mercado, Moisés

    2002-01-01

    In the follow-up of patients with well-differentiated thyroid carcinomas (WTC), a thyroid-stimulating hormone (TSH) >or=30 micro U/mL is generally accepted as adequate to perform whole body scans (WBS), determine thyroglobulin (Tg), and administer radioiodine therapeutically. These patients, inevitably rendered hypothyroid, are traditionally switched to T3 for 3-4 weeks prior to withdrawing all thyroid hormones for an additional 2-3 weeks. Neither TSH and Tg elevation dynamics nor WBS characteristics after simply interrupting L-T4 treatment without T3 administration have been evaluated. TSH, total T4 and T3, as well as FT4 were measured weekly after discontinuing L-T4 in 21 subjects (group I) and after thyroidectomy in 10 subjects (group II). WBS and Tg determination was performed upon achievement of TSH >or=30 micro U/mL. By the second week, 42% of group I patients and 70% of group II patients had TSH >or=30 micro U/mL. By the third week, 90% in group I and 100% in group II had achieved this target. Group I patients who needed 4 weeks to increase TSH received a greater cumulative radioiodine dose and had higher Tg levels. Positive WBS were found in eight cases and the incidence of a negative WBS with elevated Tg was significantly higher when evaluation occurred at the second week of L-T4 withdrawal compared to the fourth week. L-T4 interruption is a reasonable alternative to temporary T3 in preparation for radioiodine scanning and treatment.

  8. Radioiodine (131I) therapies performed in a paediatric hospital: facilities and procedures.

    PubMed

    Bibbo, Giovanni; Benger, Tracy; Sigalas, Victoria; Kirkwood, Ian

    2018-06-25

    Radioiodine ( 131 I) therapies on younger children with thyroid cancer and neuroblastoma can be challenging as they are required to be isolated for a period of time due to radiation safety concerns. At our hospital these therapies are performed in a purpose-built child-friendly therapy room. Nursing staff are able to provide personal care during the isolation period with minimum radiation exposure. Patients are provided with various age-appropriate entertainment items such as iPad, X-Box, DVD, craft and books to keep them entertained while in isolation. Parents can communicate freely with their child via the audio-visual system located in the Ward Parent Lounge and can also stay in the shielded part of the ante room of the therapy room. Nursing staff can communicate with the patient via a similar audio-visual system located in the nurses station so that they only need to enter the therapy room when they are required to provide personal patient care. All persons entering the therapy room are monitored with personal digital dosimeters. Patients accept the isolation period with minimal aggravation and the personal radiation exposures to staff, parents and visitors are well below the general public annual limit of 1000 µSv. The design and facilities of the therapy room with its child-friendly surroundings and support network makes the experience of the isolation period easier and positive for both patients and parents. For Graves' disease, the patients are treated as outpatients in the Department of Nuclear Medicine and are discharged within a short time after the radioiodine administration.

  9. Management of thyroid eye disease in the United Kingdom: A multi-centre thyroid eye disease audit.

    PubMed

    Mellington, F E; Dayan, C M; Dickinson, A J; Hickey, J L; MacEwen, C J; McLaren, J; Perros, P; Rose, G E; Uddin, J; Vaidya, B; Foley, P; Lazarus, J H; Mitchell, A; Ezra, D G

    2017-06-01

    This article aims to provide baseline data and highlight any major deficiencies in the current level of care provided for adult patients with thyroid eye disease (TED). We undertook a prospective, nonrandomized cross-sectional multicenter observational study. During a 3-month period June-August 2014, consecutive adult patients with TED who presented to nominated specialist eye clinics in the United Kingdom, completed a standardized questionnaire. Main outcome measures were: demographics, time from diagnosis to referral to tertiary centre, time from referral to review in specialist eye clinic, management of thyroid dysfunction, radioiodine and provision of steroid prophylaxis, smoking, and TED classification. 91 patients (mean age 47.88 years) were included. Female-to-male ratio was 6:1. Mean time since first symptoms of TED = 27.92 (73.71) months; from first visit to any doctor with symptoms to diagnosis = 9.37 (26.03) months; from hyperthyroidism diagnosis to euthyroidism 12.45 (16.81) months. First, 13% had received radioiodine. All those with active TED received prophylactic steroids. Seven patients who received radioiodine and did not have TED at the time went on to develop it. Then, 60% patients were current or ex-smokers. 63% current smokers had been offered smoking cessation advice. 65% patients had active TED; 4% had sight-threatening TED. A large proportion of patients (54%) were unaware of their thyroid status. Not enough patients are being provided with smoking cessation advice and information on the impact of smoking on TED and control of thyroid function.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Xuemei; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, Hubei Province; Department of Urology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, Hubei Province

    Thyroid cancer is a common malignancy of the endocrine system. Although radioiodine {sup 131}I treatment on differentiated thyroid cancer is widely used, many patients still fail to benefit from {sup 131}I therapy. Therefore, exploration of novel targeted therapies to suppress tumor growth and improve radioiodine uptake remains necessary. Bromodomain-containing protein 4 (BRD4) is an important member of the bromodomain and extra terminal domain family that influences transcription of downstream genes by binding to acetylated histones. In the present study, we found that BRD4 was up-regulated in thyroid cancer tissues and cell lines. Inhibition of BRD4 in thyroid cancer cells bymore » JQ1 resulted in cell cycle arrest at G0/G1 phase and enhanced {sup 131}I uptake in vitro and suppressed tumor growth in vivo. Moreover, JQ1 treatment suppressed C-MYC but enhanced NIS expression. We further demonstrated that BRD4 was enriched in the promoter region of C-MYC, which could be markedly blocked by JQ1 treatment. In conclusion, our findings revealed that the aberrant expression of BRD4 in thyroid cancer is possibly involved in tumor progression, and JQ1 is potentially an effective chemotherapeutic agent against human thyroid cancer. - Highlights: • BRD4 is upregulated in thyroid cancer tissues and cell lines. • Inhibition of BRD4 induced cell cycle arrest and enhanced radioiodine uptake in vitro and impaired tumor growth in vivo. • JQ1 suppressed the expression of C-MYC and promoted the expression of NIS and P21. • JQ1 attenuated the recruitment of BRD4 to MYC promoter in thyroid cancer.« less

  11. Radioiodination of scorpion and snake toxins. [/sup 125/I, /sup 127/I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rochat, H.; Tessier, M.; Miranda, F.

    1977-10-01

    Several scorpion and snake toxins were radioiodinated using the lactoperoxydase method of (/sup 125/I)iodide oxidation. Two techniques of labeling were set up: Using carrier-free Na/sup 125/I and 5 ..mu..g of toxin, about one iodine atom was incorporated per mole of protein without loss of toxicity. Specific radioactivities about 2,000 Ci/mmol (280 ..mu..Ci/..mu..g) were obtained. The modified toxin, purified by immunoprecipitation with an antiserum prepared against the native toxin, was obtained in a short time (4 hr), with a good yield (50 to 80%), and in a small volume (1 ml). Using Na/sup 127/I traced with Na /sup 125/I and largermore » amounts (200 ..mu..g) of toxin, more than one iodine atom was incorporated per mole of protein without loss of activity. Lower specific radioactivities (1 to 1.5 Ci/mmol) were obtained. The iodinated toxins were purified by gel filtration of the radioiodination mixtures on a column made of two layers of Sephadex (G-15 and G-50). The modified proteins were extensively analyzed by paper electrophoresis and polyacrylamide gel electrophoresis. Their content of monoiodotyrosine and diiodotyrosine was estimated and, in the case of toxin I of Androctonus australis Hector, it was possible to follow the iodination rate of its three tyrosine residues by automatic Edman degradation. The mode of purification of the iodinated scorpion toxins affects their behavior on molecular sieving on Sephadex G-50 and on electrophoresis on polyacrylamide gel. The results are discussed.« less

  12. Animal models of disease: feline hyperthyroidism: an animal model for toxic nodular goiter.

    PubMed

    Peterson, Mark E

    2014-11-01

    Since first discovered just 35 years ago, the incidence of spontaneous feline hyperthyroidism has increased dramatically to the extent that it is now one of the most common disorders seen in middle-aged to senior domestic cats. Hyperthyroid cat goiters contain single or multiple autonomously (i.e. TSH-independent) functioning and growing thyroid nodules. Thus, hyperthyroidism in cats is clinically and histologically similar to toxic nodular goiter in humans. The disease in cats is mechanistically different from Graves' disease, because neither the hyperfunction nor growth of these nodules depends on extrathyroidal circulating stimulators. The basic lesion appears to be an excessive intrinsic growth capacity of some thyroid cells, but iodine deficiency, other nutritional goitrogens, or environmental disruptors may play a role in the disease pathogenesis. Clinical features of feline toxic nodular goiter include one or more palpable thyroid nodules, together with signs of hyperthyroidism (e.g. weight loss despite an increased appetite). Diagnosis of feline hyperthyroidism is confirmed by finding the increased serum concentrations of thyroxine and triiodothyronine, undetectable serum TSH concentrations, or increased thyroid uptake of radioiodine. Thyroid scintigraphy demonstrates a heterogeneous pattern of increased radionuclide uptake, most commonly into both thyroid lobes. Treatment options for toxic nodular goiter in cats are similar to that used in humans and include surgical thyroidectomy, radioiodine, and antithyroid drugs. Most authorities agree that ablative therapy with radioiodine is the treatment of choice for most cats with toxic nodular goiter, because the animals are older, and the disease will never go into remission. © 2014 Society for Endocrinology.

  13. Safety regulations of food and water implemented in the first year following the Fukushima nuclear accident

    PubMed Central

    Hamada, Nobuyuki; Ogino, Haruyuki; Fujimichi, Yuki

    2012-01-01

    An earthquake and tsunami of historic proportions caused massive damage across the northeastern coast of Japan on the afternoon of 11 March 2011, and the release of radionuclides from the stricken reactors of the Fukushima nuclear power plant 1 was detected early on the next morning. High levels of radioiodines and radiocesiums were detected in the topsoil and plants on 15 March 2011, so sampling of food and water for monitoring surveys began on 16 March 2011. On 17 March 2011, provisional regulation values for radioiodine, radiocesiums, uranium, plutonium and other transuranic α emitters were set to regulate the safety of radioactively contaminated food and water. On 21 March 2011, the first restrictions on distribution and consumption of contaminated items were ordered. So far, tap water, raw milk, vegetables, mushrooms, fruit, nut, seaweeds, marine invertebrates, coastal fish, freshwater fish, beef, wild animal meat, brown rice, wheat, tea leaves and other foodstuffs had been contaminated above the provisional regulation values. The provisional regulation values for radioiodine were exceeded in samples taken from 16 March 2011 to 21 May 2011, and those for radiocesiums from 18 March 2011 to date. All restrictions were imposed within 318 days after the provisional regulation values were first exceeded for each item. This paper summarizes the policy for the execution of monitoring surveys and restrictions, and the outlines of the monitoring results of 220 411 samples and the enforced restrictions predicated on the information available as of 31 March 2012. PMID:22843368

  14. [Efficacy of treatment with I(131) in paediatric Graves disease].

    PubMed

    Enes Romero, P; Martín-Frías, M; de Jesús, M; Caballero Loscos, C; Alonso Blanco, M; Barrio Castellanos, R

    2014-01-01

    Radioiodine is an important therapeutic option in young patients with Grave's disease (GD). In the United States it is a widespread therapy, but in Europe its use in paediatrics is still controversial. To report our experience in radioiodine therapy of paediatric GD patients and analyse its effectiveness and safety. We retrospectively studied our paediatric population (<18 years of age) with GD, diagnosed from 1982 to 2012. A curative option was offered to patients who did not respond to anti-thyroid drug (AT) at puberty. We analysed, the patient characteristics, TSH, T4, T3 and thyroid antibodies levels, AT response, remission post I(131), side effects, and hypothyroidism rates. A total of 50 patients were diagnosed with GD from 1982 to 2012. All patients received AT as initial treatment (mean duration: 35.3±25.9 months). Permanent remission was achieved in 46%. Thyroidectomy was performed in 5 patients, and 14 patients received I(131) (mean dose: 10.9±1.09 mCi). Remission with I(131) was obtained in 100%. The rate of permanent hypothyroidism was 90%. There was no progression of ophthalmopathy or side effects in any patients treated with I(131.) Radioiodine treatment of paediatric GD patients is safe, leads to complete remission at the expense of hypothyroidism, and does not exacerbate ophthalmopathy. It can be considered in patients older than 5 years, who do no not respond to AT or with significant side effects with this medication. Copyright © 2012 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  15. Intercomparisons of Marine Boundary Layer Cloud Properties from the ARM CAP-MBL Campaign and Two MODIS Cloud Products

    NASA Technical Reports Server (NTRS)

    Zhang, Zhibo; Dong, Xiquan; Xi, Baike; Song, Hua; Ma, Po-Lun; Ghan, Steven J.; Platnick, Steven; Minnis, Patrick

    2017-01-01

    From April 2009 to December 2010, the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) program carried out an observational field campaign on Graciosa Island, targeting the marine boundary layer (MBL) clouds over the Azores region. In this paper, we present an inter-comparison of the MBL cloud properties, namely, cloud liquid water path (LWP), cloud optical thickness (COT) and cloud-droplet effective radius (CER), among retrievals from the ARM mobile facility (AMF) and two Moderate Resolution Spectroradiometer (MODIS) cloud products (GSFC-MODIS and CERES-MODIS). A total of 63 daytime single-layer MBL cloud cases are selected for inter-comparison. Comparison of collocated retrievals indicates that the two MODIS cloud products agree well on both COT and CER retrievals, with the correlation coefficient R greater than 0.95 despite their significant difference in spatial sampling. In both MODIS products, the CER retrievals based on the 2.1 micrometers band (CER(sub 2.1)) is significantly smaller than that based on the 3.7 micrometers band (CER(sub 3.7)). The GSFC-MODIS cloud product is collocated and compared with ground-based ARM observations at several temporal spatial scales. In general, the correlation increases with more precise collocation. For the 63 selected MBL cloud cases, the GSFC-MODIS LWP and COT retrievals agree reasonably well with the ground-based observations with no apparent bias and correlation coefficient R around 0.85 and 0.70, respectively. However, GSFC-MODIS CER(sub 3.7) and CER(sub 2.1) retrievals have a lower correlation (R is approximately 0.5) with the ground-based retrievals. For the 63 selected cases, they are on average larger than ground observations by about 1.5 micrometers and 3.0 micrometers, respectively. Taking into account that the MODIS CER retrievals are only sensitive to cloud top reduces the bias only by 0.5 micrometers.

  16. Intercomparisons of marine boundary layer cloud properties from the ARM CAP-MBL campaign and two MODIS cloud products

    NASA Astrophysics Data System (ADS)

    Zhang, Zhibo; Dong, Xiquan; Xi, Baike; Song, Hua; Ma, Po-Lun; Ghan, Steven J.; Platnick, Steven; Minnis, Patrick

    2017-02-01

    From April 2009 to December 2010, the Department of Energy Atmospheric Radiation Measurement (ARM) program carried out an observational field campaign on Graciosa Island, targeting the marine boundary layer (MBL) clouds over the Azores region. In this paper, we present an intercomparison of the MBL cloud properties, namely, cloud liquid water path (LWP), cloud optical thickness (COT), and cloud-droplet effective radius (CER), among retrievals from the ARM mobile facility and two Moderate Resolution Imaging Spectroradiometer (MODIS) cloud products (Goddard Space Flight Center (GSFC)-MODIS and Clouds and Earth's Radiant Energy System-MODIS). A total of 63 daytime single-layer MBL cloud cases are selected for intercomparison. Comparison of collocated retrievals indicates that the two MODIS cloud products agree well on both COT and CER retrievals, with the correlation coefficient R > 0.95, despite their significant difference in spatial sampling. In both MODIS products, the CER retrievals based on the 2.1 µm band (CER2.1) are significantly larger than those based on the 3.7 µm band (CER3.7). The GSFC-MODIS cloud product is collocated and compared with ground-based ARM observations at several temporal-spatial scales. In general, the correlation increases with more precise collocation. For the 63 selected MBL cloud cases, the GSFC-MODIS LWP and COT retrievals agree reasonably well with the ground-based observations with no apparent bias and correlation coefficient R around 0.85 and 0.70, respectively. However, GSFC-MODIS CER3.7 and CER2.1 retrievals have a lower correlation (R 0.5) with the ground-based retrievals. For the 63 selected cases, they are on average larger than ground observations by about 1.5 µm and 3.0 µm, respectively. Taking into account that the MODIS CER retrievals are only sensitive to cloud top reduces the bias only by 0.5 µm.

  17. The Earth System Documentation (ES-DOC) Software Process

    NASA Astrophysics Data System (ADS)

    Greenslade, M. A.; Murphy, S.; Treshansky, A.; DeLuca, C.; Guilyardi, E.; Denvil, S.

    2013-12-01

    Earth System Documentation (ES-DOC) is an international project supplying high-quality tools & services in support of earth system documentation creation, analysis and dissemination. It is nurturing a sustainable standards based documentation eco-system that aims to become an integral part of the next generation of exa-scale dataset archives. ES-DOC leverages open source software, and applies a software development methodology that places end-user narratives at the heart of all it does. ES-DOC has initially focused upon nurturing the Earth System Model (ESM) documentation eco-system and currently supporting the following projects: * Coupled Model Inter-comparison Project Phase 5 (CMIP5); * Dynamical Core Model Inter-comparison Project (DCMIP); * National Climate Predictions and Projections Platforms Quantitative Evaluation of Downscaling Workshop. This talk will demonstrate that ES-DOC implements a relatively mature software development process. Taking a pragmatic Agile process as inspiration, ES-DOC: * Iteratively develops and releases working software; * Captures user requirements via a narrative based approach; * Uses online collaboration tools (e.g. Earth System CoG) to manage progress; * Prototypes applications to validate their feasibility; * Leverages meta-programming techniques where appropriate; * Automates testing whenever sensibly feasible; * Streamlines complex deployments to a single command; * Extensively leverages GitHub and Pivotal Tracker; * Enforces strict separation of the UI from underlying API's; * Conducts code reviews.

  18. Intercomparison of aerosol optical parameters from WALI and R-MAN510 aerosol Raman lidars in the framework of HyMeX campaign

    NASA Astrophysics Data System (ADS)

    Boytard, Mai-Lan; Royer, Philippe; Chazette, Patrick; Shang, Xiaoxia; Marnas, Fabien; Totems, Julien; Bizard, Anthony; Bennai, Baya; Sauvage, Laurent

    2013-04-01

    The HyMeX program (Hydrological cycle in Mediterranean eXperiment) aims at improving our understanding of hydrological cycle in the Mediterranen and at a better quantification and forecast of high-impact weather events in numerical weather prediction models. The first Special Observation Period (SOP1) took place in September/October 2012. During this period two aerosol Raman lidars have been deployed at Menorca Island (Spain) : one Water-vapor and Aerosol Raman LIdar (WALI) operated by LSCE/CEA (Laboratoire des Sciences du Climat et de l'Environnement/Commissariat à l'Energie Atomique) and one aerosol Raman and dual-polarization lidar (R-Man510) developed and commercialized by LEOSPHERE company. Both lidars have been continuously running during the campaign and have provided information on aerosol and cloud optical properties under various atmospheric conditions (maritime background aerosols, dust events, cirrus clouds...). We will present here the results of intercomparisons between R-Man510, and WALI aerosol lidar systems and collocated sunphotometer measurements. Limitations and uncertainties on the retrieval of extinction coefficients, depolarization ratio, aerosol optical depths and detection of atmospheric structures (planetary boundary layer height, aerosol/cloud layers) will be discussed according atmospheric conditions. The results will also be compared with theoretical uncertainty assessed with direct/inverse model of lidar profiles.

  19. Diagnosis and treatment of Graves disease.

    PubMed

    Streetman, Darcie D; Khanderia, Ujjaini

    2003-01-01

    To review the etiology, diagnosis, and clinical presentation of Graves disease and provide an overview of the standard and adjunctive treatments. Specifically, antithyroid drugs, beta-blockers, inorganic iodide, lithium, and radioactive iodine are discussed, focusing on current controversies. Primary articles were identified through a MEDLINE search (1966-July 2000). Key word searches included beta-blockers, Graves disease, inorganic iodide, lithium, methimazole, and propylthiouracil. Additional articles from these sources and endocrinology textbooks were also identified. We agreed to include articles that would highlight the most relevant points, as well as current areas of controversy. Graves disease is the most common cause of hyperthyroidism. The 3 main treatment options for patients with Graves hyperthyroidism include antithyroid drugs, radioactive iodine, and surgery. Although the antithyroid drugs propylthiouracil (PTU) and methimazole (MMI) have similar efficacy, there are situations when 1 agent is preferred. MMI has a longer half-life than PTU, allowing once-daily dosing that can improve patient adherence to treatment. PTU has historically been the drug of choice for treating pregnant and breast-feeding women because of its limited transfer into the placenta and breast milk. Adjuvant therapies for Graves disease include beta-blockers, inorganic iodide, and lithium. beta-Blockers are used to decrease the symptoms of hyperthyroidism. Inorganic iodide is primarily used to prepare patients for thyroid surgery because of its ability to decrease the vascularity of the thyroid gland. Lithium, which acts in a manner similar to iodine, is not routinely used due to its transient effect and the risk of potentially serious adverse effects. In the US, radioiodine therapy has become the preferred treatment for adults with Graves disease. It is easy to administer, safe, effective, and more affordable than long-term treatment with antithyroid drugs. Hypothyroidism is an inevitable consequence of radioiodine therapy. Radioiodine is contraindicated in pregnant women because it can damage the fetal thyroid gland, resulting in fetal hypothyroidism. Bilateral subtotal thyroidectomy, which was once the only treatment available, is now performed only in special circumstances. In addition to the normal risks associated with surgery, laryngeal nerve damage, hypoparathyroidism, and hypothyroidism can occur following that procedure. Despite extensive experience with medical management, controversy prevails regarding choosing among the various drugs for treatment of Graves disease. None of the treatment options, including antithyroid drugs, radioiodine, and surgery, is ideal. Each has risks and benefits, and selection should be tailored to the individual patient.

  20. A Bootstrap Algorithm for Mixture Models and Interval Data in Inter-Comparisons

    DTIC Science & Technology

    2001-07-01

    parametric bootstrap. The present algorithm will be applied to a thermometric inter-comparison, where data cannot be assumed to be normally distributed. 2 Data...experimental methods, used in each laboratory) often imply that the statistical assumptions are not satisfied, as for example in several thermometric ...triangular). Indeed, in thermometric experiments these three probabilistic models can represent several common stochastic variabilities for

  1. High Resolution Model Intercomparison Project (HighResMIP v1.0) for CMIP6

    DOE PAGES

    Haarsma, Reindert J.; Roberts, Malcolm J.; Vidale, Pier Luigi; ...

    2016-11-22

    Robust projections and predictions of climate variability and change, particularly at regional scales, rely on the driving processes being represented with fidelity in model simulations. The role of enhanced horizontal resolution in improved process representation in all components of the climate system is of growing interest, particularly as some recent simulations suggest both the possibility of significant changes in large-scale aspects of circulation as well as improvements in small-scale processes and extremes. However, such high-resolution global simulations at climate timescales, with resolutions of at least 50 km in the atmosphere and 0.25° in the ocean, have been performed at relativelymore » few research centres and generally without overall coordination, primarily due to their computational cost. Assessing the robustness of the response of simulated climate to model resolution requires a large multi-model ensemble using a coordinated set of experiments. The Coupled Model Intercomparison Project 6 (CMIP6) is the ideal framework within which to conduct such a study, due to the strong link to models being developed for the CMIP DECK experiments and other model intercomparison projects (MIPs). Increases in high-performance computing (HPC) resources, as well as the revised experimental design for CMIP6, now enable a detailed investigation of the impact of increased resolution up to synoptic weather scales on the simulated mean climate and its variability. The High Resolution Model Intercomparison Project (HighResMIP) presented in this paper applies, for the first time, a multi-model approach to the systematic investigation of the impact of horizontal resolution. A coordinated set of experiments has been designed to assess both a standard and an enhanced horizontal-resolution simulation in the atmosphere and ocean. The set of HighResMIP experiments is divided into three tiers consisting of atmosphere-only and coupled runs and spanning the period 1950–2050, with the possibility of extending to 2100, together with some additional targeted experiments. This paper describes the experimental set-up of HighResMIP, the analysis plan, the connection with the other CMIP6 endorsed MIPs, as well as the DECK and CMIP6 historical simulations. Lastly, HighResMIP thereby focuses on one of the CMIP6 broad questions, “what are the origins and consequences of systematic model biases?”, but we also discuss how it addresses the World Climate Research Program (WCRP) grand challenges.« less

  2. Intercomparison of TCCON and MUSICA Water Vapour Products

    NASA Astrophysics Data System (ADS)

    Weaver, D.; Strong, K.; Deutscher, N. M.; Schneider, M.; Blumenstock, T.; Robinson, J.; Notholt, J.; Sherlock, V.; Griffith, D. W. T.; Barthlott, S.; García, O. E.; Smale, D.; Palm, M.; Jones, N. B.; Hase, F.; Kivi, R.; Ramos, Y. G.; Yoshimura, K.; Sepúlveda, E.; Gómez-Peláez, Á. J.; Gisi, M.; Kohlhepp, R.; Warneke, T.; Dohe, S.; Wiegele, A.; Christner, E.; Lejeune, B.; Demoulin, P.

    2014-12-01

    We present an intercomparison between the water vapour products from the Total Carbon Column Observing Network (TCCON) and the MUlti-platform remote Sensing of Isotopologues for investigating the Cycle of Atmospheric water (MUSICA), two datasets from ground-based Fourier Transform InfraRed (FTIR) spectrometers with good global representation. Where possible, comparisons to radiosondes are also included. The near-infrared TCCON measurements are optimized to provide precise monitoring of greenhouse gases for carbon cycle studies; however, TCCON's retrievals also produce water vapour products. The mid-infrared MUSICA products result from retrievals optimized to give precise and accurate information about H2O, HDO, and δD. The MUSICA water vapour products have been validated by extensive intercomparisons with H2O and δD in-situ measurements made from ground, radiosonde, and aircraft (Schneider et al. 2012, 2014), as well as by intercomparisons with satellite-based H2O and δD remote sensing measurements (Wiegele et al., 2014). This dataset provides a valuable reference point for other measurements of water vapour. This study is motivated by the limited intercomparisons performed for TCCON water vapour products and limited characterisation of their uncertainties. We compare MUSICA and TCCON products to assess the potential for TCCON measurements to contribute to studies of the water cycle, water vapour's role in climate and use as a tracer for atmospheric dynamics, and to evaluate the performance of climate models. The TCCON and MUSICA products result from measurements taken using the same FTIR instruments, enabling a comparison with constant instrumentation. The retrieval techniques differ, however, in their method and a priori information. We assess the impact of these differences and characterize the comparability of the TCCON and MUSICA datasets.

  3. An evaluation of the Wyoming Gauge System for snowfall measurement

    USGS Publications Warehouse

    Yang, Daqing; Kane, Douglas L.; Hinzman, Larry D.; Goodison, Barry E.; Metcalfe, John R.; Louie, Paul Y.T.; Leavesley, George H.; Emerson, Douglas G.; Hanson, Clayton L.

    2000-01-01

    The Wyoming snow fence (shield) has been widely used with precipitation gauges for snowfall measurement at more than 25 locations in Alaska since the late 1970s. This gauge's measurements have been taken as the reference for correcting wind‐induced gauge undercatch of snowfall in Alaska. Recently, this fence (shield) was tested in the World Meteorological Organization Solid Precipitation Measurement Intercomparison Project at four locations in the United States of America and Canada for six winter seasons. At the Intercomparison sites an octagonal vertical Double Fence with a Russian Tretyakov gauge or a Universal Belfort recording gauge was installed and used as the Intercomparison Reference (DFIR) to provide true snowfall amounts for this Intercomparison experiment. The Intercomparison data collected were compiled at the four sites that represent a variety of climate, terrain, and exposure. On the basis of these data sets the performance of the Wyoming gauge system for snowfall observations was carefully evaluated against the DFIR and snow cover data. The results show that (1) the mean snow catch efficiency of the Wyoming gauge compared with the DFIR is about 80–90%, (2) there exists a close linear relation between the measurements of the two gauge systems and this relation may serve as a transfer function to adjust the Wyoming gauge records to obtain an estimate of the true snowfall amount, (3) catch efficiency of the Wyoming gauge does not change with wind speed and temperature, and (4) Wyoming gauge measurements are generally compatible to the snowpack water equivalent at selected locations in northern Alaska. These results are important to our effort of determining true snowfall amounts in the high latitudes, and they are also useful for regional hydrologic and climatic analyses.

  4. Water vapour intercomparison effort in the frame of HyMeX-SOP1

    NASA Astrophysics Data System (ADS)

    Summa, Donato; Di Girolamo, Paolo; Stelitano, Dario; Cacciani, Marco; Flamant, Cyrille; Chazette, Patrick; Ducrocq, Véronique; Nuret, Mathieu; Fourié, Nadia; Richard, Evelyne

    2014-05-01

    A water vapour intercomparison effort, involving airborne and ground-based water vapour lidar systems and mesoscale models, was carried out in the framework of the international HyMeX (Hydrological cycle in the Mediterranean Experiment) dedicated to the hydrological cycle and related high-impact events. Within HyMeX, a major field campaign was dedicated to heavy precipitation and flash flood events from 5 September to 6 November 2012. The 2 month field campaign took place over the Northwestern Mediterranean Sea and its surrounding coastal regions in France, Italy, and Spain. The main objective of this work is to provide accurate error estimates for the lidar systems i.e. the ground-based Raman lidar BASIL and the CNRS DIAL Leandre 2 on board the ATR42, as well as use BASIL data to validate mesoscale model results from the MESO NH and Arome WMED. The effort will benefit from the few dedicated ATR42 flights in the frame of the EUFAR Project "WaLiTemp". In the present work our attention was focused on two specific case studies: 13 September and 2 October in the altitude region 0.5 - 5.5 km. Comparisons between the ground-based Raman lidar BASIL and the airborne CNRS DIAL indicate a mean relative bias between the two sensors of 6.5%, while comparisons between BASIL and CNRS DIAL vs. the radiosondes indicate a bias of 2.6 and -3.5 %, respectively. The bias of BASIL vs. the ATR insitu sensor indicate a bias of -20.4 %. Specific attention will also be dedicated to the WALI/BASIL intercomparison effort which took place in Candillargues on 30 October 2012. Specific results from this intercomparison effort and from the intercomparison between BASIL and Meso-NH/AROME-WMed will be illustrated and discussed at the Conference.

  5. An international marine-atmospheric {sup 222}Rn measurement intercomparison in Bermuda. Part 2: Results for the participating laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colle, R.; Unterweger, M.P.; Hutchinson, J.M.R.

    1996-01-01

    As part of an international measurement intercomparison of instruments used to measure atmospheric {sup 222}Rn, four participating laboratories made nearly simultaneous measurements of {sup 222}Rn activity concentration in commonly sampled, ambient air over approximately a 2 week period, and three of these four laboratories participated in the measurement comparison of 14 introduced samples with known, but undisclosed (blind) {sup 222}Rn activity concentration. The exercise was conducted in Bermuda in October 1991. The {sup 222}Rn activity concentrations in ambient Bermudian air over the course of the intercomparison ranged from a few hundredths of a Bq {center_dot} m{sup {minus}3} to about 2more » Bq {center_dot} m{sup {minus}3}, while the standardized sample additions covered a range from approximately 2.5 Bq {center_dot} m{sup {minus}3} to 35 Bq {center_dot} m{sup {minus}3}. The overall uncertainty in the latter concentrations was in the general range of 10%, approximating a 3 standard deviation uncertainty interval. The results of the intercomparison indicated that two of the laboratories were within very good agreement with the standard additions, and almost within expected statistical variations. These same two laboratories, however, at lower ambient concentrations, exhibited a systematic difference with an averaged offset of roughly 0.3 Bq {center_dot} m{sup {minus}3}. The third laboratory participating in the measurement of standardized sample additions was systematically low by about 65% to 70%, with respect to the standard addition which was also confirmed in their ambient air concentration measurements. The fourth laboratory, participating in only the ambient measurement part of the intercomparison, was also systematically low by at least 40% with respect to the first two laboratories.« less

  6. Evaporation of iodine-containing off-gas scrubber solution

    DOEpatents

    Partridge, J.A.; Bosuego, G.P.

    1980-07-14

    Mercuric nitrate-nitric acid scrub solutions containing radioiodine may be reduced in volume without excessive loss of volatile iodine. The use of concentrated nitric acid during an evaporation process oxidizes the mercury-iodide complex to a less volatile mercuric iodate precipitate.

  7. Radioiodine therapy

    MedlinePlus

    ... 3 days after treatment, you should: Limit your time in public places Not travel by airplane or use public transportation (you may set off the radiation detection machines in airports or at border ... the toilet 2 to 3 times after use For about 5 or more days ...

  8. 1989 Intercomparison of radon progeny measurement methods and equipment in North America

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scofield, P.; George, A.; Tu, Keng.

    1990-03-01

    At the 1989 {sup 222}Rn progeny intercomparison held at the Environmental Measurements Laboratory (EML), July 10--14, 1989, grab sampling and integrating/continuous {sup 222}Rn progeny methods were evaluated. Sixteen facilities participated in this intercomparison. Twelve facilities used {sup 222}Rn progeny grab sampling methods, and nine facilities used integrating/continuous instruments. Eighty-eight percent of the participants reported grab sample {sup 222}Rn progeny concentrations that were within 20% of the EML reference values. Good agreement between participant and EML grab-sample potential alpha energy concentrations (PAECs) was observed; 92% of the participants had PAECs within 20% of the EML values. For the integrating/continuous PAEC valuesmore » determined with integrating/continuous monitors, 89% of the participants were within 20% of the EML reference values. 9 refs., 3 figs., 4 tabs.« less

  9. Control vocabulary software designed for CMIP6

    NASA Astrophysics Data System (ADS)

    Nadeau, D.; Taylor, K. E.; Williams, D. N.; Ames, S.

    2016-12-01

    The Coupled Model Intercomparison Project Phase 6 (CMIP6) coordinates a number of intercomparison activities and includes many more experiments than its predecessor, CMIP5. In order to organize and facilitate use of the complex collection of expected CMIP6 model output, a standard set of descriptive information has been defined, which must be stored along with the data. This standard information enables automated machine interpretation of the contents of all model output files. The standard metadata is stored in compliance with the Climate and Forecast (CF) standard, which ensures that it can be interpreted and visualized by many standard software packages. Additional attributes (not standardized by CF) are required by CMIP6 to enhance identification of models and experiments, and to provide additional information critical for interpreting the model results. To ensure that CMIP6 data complies with the standards, a python program called "PrePARE" (Pre-Publication Attribute Reviewer for the ESGF) has been developed to check the model output prior to its publication and release for analysis. If, for example, a required attribute is missing or incorrect (e.g., not included in the reference CMIP6 controlled vocabularies), then PrePare will prevent publication. In some circumstances, missing attributes can be created or incorrect attributes can be replaced automatically by PrePARE, and the program will warn users about the changes that have been made. PrePARE provides a final check on model output assuring adherence to a baseline conformity across the output from all CMIP6 models which will facilitate analysis by climate scientists. PrePARE is flexible and can be easily modified for use by similar projects that have a well-defined set of metadata and controlled vocabularies.

  10. PFLOTRAN-RepoTREND Source Term Comparison Summary.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frederick, Jennifer M.

    Code inter-comparison studies are useful exercises to verify and benchmark independently developed software to ensure proper function, especially when the software is used to model high-consequence systems which cannot be physically tested in a fully representative environment. This summary describes the results of the first portion of the code inter-comparison between PFLOTRAN and RepoTREND, which compares the radionuclide source term used in a typical performance assessment.

  11. GLM Proxy Data Generation: Methods for Stroke/Pulse Level Inter-Comparison of Ground-Based Lightning Reference Networks

    NASA Technical Reports Server (NTRS)

    Cummins, Kenneth L.; Carey, Lawrence D.; Schultz, Christopher J.; Bateman, Monte G.; Cecil, Daniel J.; Rudlosky, Scott D.; Petersen, Walter Arthur; Blakeslee, Richard J.; Goodman, Steven J.

    2011-01-01

    In order to produce useful proxy data for the GOES-R Geostationary Lightning Mapper (GLM) in regions not covered by VLF lightning mapping systems, we intend to employ data produced by ground-based (regional or global) VLF/LF lightning detection networks. Before using these data in GLM Risk Reduction tasks, it is necessary to have a quantitative understanding of the performance of these networks, in terms of CG flash/stroke DE, cloud flash/pulse DE, location accuracy, and CLD/CG classification error. This information is being obtained through inter-comparison with LMAs and well-quantified VLF/LF lightning networks. One of our approaches is to compare "bulk" counting statistics on the spatial scale of convective cells, in order to both quantify relative performance and observe variations in cell-based temporal trends provided by each network. In addition, we are using microsecond-level stroke/pulse time correlation to facilitate detailed inter-comparisons at a more-fundamental level. The current development status of our ground-based inter-comparison and evaluation tools will be presented, and performance metrics will be discussed through a comparison of Vaisala s Global Lightning Dataset (GLD360) with the NLDN at locations within and outside the U.S.

  12. GLM Proxy Data Generation: Methods for Stroke/Pulse Level Inter-comparison of Ground-based Lightning Reference Networks

    NASA Astrophysics Data System (ADS)

    Cummins, K. L.; Carey, L. D.; Schultz, C. J.; Bateman, M. G.; Cecil, D. J.; Rudlosky, S. D.; Petersen, W. A.; Blakeslee, R. J.; Goodman, S. J.

    2011-12-01

    In order to produce useful proxy data for the GOES-R Geostationary Lightning Mapper (GLM) in regions not covered by VLF lightning mapping systems, we intend to employ data produced by ground-based (regional or global) VLF/LF lightning detection networks. Before using these data in GLM Risk Reduction tasks, it is necessary to have a quantitative understanding of the performance of these networks, in terms of CG flash/stroke DE, cloud flash/pulse DE, location accuracy, and CLD/CG classification error. This information is being obtained through inter-comparison with LMAs and well-quantified VLF/LF lightning networks. One of our approaches is to compare "bulk" counting statistics on the spatial scale of convective cells, in order to both quantify relative performance and observe variations in cell-based temporal trends provided by each network. In addition, we are using microsecond-level stroke/pulse time correlation to facilitate detailed inter-comparisons at a more-fundamental level. The current development status of our ground-based inter-comparison and evaluation tools will be presented, and performance metrics will be discussed through a comparison of Vaisala's Global Lightning Dataset (GLD360) with the NLDN at locations within and outside the U.S.

  13. Evaluation of Intercomparisons of Four Different Types of Model Simulating TWP-ICE

    NASA Technical Reports Server (NTRS)

    Petch, Jon; Hill, Adrian; Davies, Laura; Fridlind, Ann; Jakob, Christian; Lin, Yanluan; Xie, Shaoecheng; Zhu, Ping

    2013-01-01

    Four model intercomparisons were run and evaluated using the TWP-ICE field campaign, each involving different types of atmospheric model. Here we highlight what can be learnt from having single-column model (SCM), cloud-resolving model (CRM), global atmosphere model (GAM) and limited-area model (LAM) intercomparisons all based around the same field campaign. We also make recommendations for anyone planning further large multi-model intercomparisons to ensure they are of maximum value to the model development community. CRMs tended to match observations better than other model types, although there were exceptions such as outgoing long-wave radiation. All SCMs grew large temperature and moisture biases and performed worse than other model types for many diagnostics. The GAMs produced a delayed and significantly reduced peak in domain-average rain rate when compared to the observations. While it was shown that this was in part due to the analysis used to drive these models, the LAMs were also driven by this analysis and did not have the problem to the same extent. Based on differences between the models with parametrized convection (SCMs and GAMs) and those without (CRMs and LAMs), we speculate that that having explicit convection helps to constrain liquid water whereas the ice contents are controlled more by the representation of the microphysics.

  14. The Southern Ocean in the Coupled Model Intercomparison Project phase 5

    PubMed Central

    Meijers, A. J. S.

    2014-01-01

    The Southern Ocean is an important part of the global climate system, but its complex coupled nature makes both its present state and its response to projected future climate forcing difficult to model. Clear trends in wind, sea-ice extent and ocean properties emerged from multi-model intercomparison in the Coupled Model Intercomparison Project phase 3 (CMIP3). Here, we review recent analyses of the historical and projected wind, sea ice, circulation and bulk properties of the Southern Ocean in the updated Coupled Model Intercomparison Project phase 5 (CMIP5) ensemble. Improvements to the models include higher resolutions, more complex and better-tuned parametrizations of ocean mixing, and improved biogeochemical cycles and atmospheric chemistry. CMIP5 largely reproduces the findings of CMIP3, but with smaller inter-model spreads and biases. By the end of the twenty-first century, mid-latitude wind stresses increase and shift polewards. All water masses warm, and intermediate waters freshen, while bottom waters increase in salinity. Surface mixed layers shallow, warm and freshen, whereas sea ice decreases. The upper overturning circulation intensifies, whereas bottom water formation is reduced. Significant disagreement exists between models for the response of the Antarctic Circumpolar Current strength, for reasons that are as yet unclear. PMID:24891395

  15. 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swaja, R.E.; Greene, R.T.; Sims, C.S.

    1985-04-01

    An international intercomparison of nuclear accident dosimetry systems was conducted during September 12-16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. This study marked the twentieth in a series of annual accident dosimetry intercomparisons conducted at ORNL. Participants from ten organizations attended this intercomparison and measured neutron and gamma doses at area monitoring stations and on phantoms for three different shield conditions. Results of this study indicate that foil activation techniques are the most popular and accurate method of determining accident-level neutron doses at area monitoringmore » stations. For personnel monitoring, foil activation, blood sodium activation, and thermoluminescent (TL) methods are all capable of providing accurate dose estimates in a variety of radiation fields. All participants in this study used TLD's to determine gamma doses with very good results on the average. Chemical dosemeters were also shown to be capable of yielding accurate estimates of total neutron plus gamma doses in a variety of radiation fields. While 83% of all neutron measurements satisfied regulatory standards relative to reference values, only 39% of all gamma results satisfied corresponding guidelines for gamma measurements. These results indicate that continued improvement in accident dosimetry evaluation and measurement techniques is needed.« less

  16. Imaging agent and method of use

    DOEpatents

    Wieland, Donald M.; Brown, Lawrence E.; Beierwaltes, William H.; Wu, Jiann-long

    1986-04-22

    A new radiopharmaceutical composition for use in nuclear medicine comprises a radioiodinated meta-iodobenzylguanidine. The composition is used as an imaging agent for the heart, adrenal medulla, and tumors of the adrenal medulla and can be used for treatment of tumors of the adrenal medulla.

  17. Airborne hygrometer calibration inter-comparison against a metrological water vapour standard

    NASA Astrophysics Data System (ADS)

    Smorgon, Denis; Boese, Norbert; Ebert, Volker

    2014-05-01

    Water vapour is the most important atmospheric greenhouse gas, which causes a major feedback to warming and other changes in the climate system. Knowledge of the distribution of water vapour and its climate induced changes is especially important in the upper troposphere and lower stratosphere (UT/LS) where vapour plays a critical role in atmospheric radiative balance, cirrus cloud formation, and photochemistry. But, our understanding of water in the UT/LS is limited by significant uncertainties in current UT/LS water measurements. One of the most comprehensive inter-comparison campaigns for airborne hygrometers, termed AQUAVIT (AV1) [1], took place in 2007 at the AIDA chamber at the Karlsruhe Institute of Technology (KIT) in Germany. AV1 was a well-defined, referred, blind inter-comparison of 22 airborne field instruments from 17 international research groups. One major metrological deficit of AV1, however, was, that no traceable reference instrument participated in the inter-comparison experiments and that the calibration procedures of the participating instruments were not monitored or interrogated. Consequently a follow-up inter-comparison was organized in April 2013, which for the first time also provides a traceable link to the international humidity scale. This AQUAVIT2 (AV2) campaign (details see: http://www.imk-aaf.kit.edu/aquavit/index.php/Main_Page) was again located at KIT/AIDA and organised by an international organizing committee including KIT, PTB, FZJ and others. Generally AV2 is divided in two parallel comparisons: 1) AV2-A uses the AIDA chamber for a simultaneous comparison of all instruments (incl. sampling and in-situ instruments) over a broad range of conditions characteristic for the UT/LS; 2) AV2-B, about which this paper is reporting, is a sequential comparison of selected hygrometers and (when possible) their reference calibration infrastructures by means of a chilled mirror hygrometer traced back to the primary National humidity standard of PTB and a validated, two-pressure generator acting as a highly stable and reproducible source of water vapour. The aim of AV2-B was to perform an absolute, metrological comparison of the field instruments/calibration infrastructures to the metrological humidity scale, and to collect essential information about methods and procedures used by the atmospheric community for instrument calibration and validation, in order to investigate e.g. the necessity and possible comparability advantage by a standardized calibration procedure. The work will give an overview over the concept of the AV2-B inter-comparison, the various general measurement and calibration principles, and discuss the outcome and consequences of the comparison effort. The AQUAVIT effort is linked to the EMRP project METEOMET (ENV07) and partially supported by the EMRP and ENV07. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. [1] H. Saathoff, C. Schiller, V. Ebert, D. W. Fahey, R.-S. Gao, O. Möhler, and the aquavit team, The AQUAVIT formal intercomparison of atmospheric water measurement methods, 5th General Assembly of the European Geosciences Union, 13-18 April 2008, Vienna, Austria Keywords: humidity, water vapour, inter-comparison, airborne instruments.

  18. The limit of detection in scintigraphic imaging with I-131 in patients with differentiated thyroid carcinoma

    NASA Astrophysics Data System (ADS)

    Hänscheid, H.; Lassmann, M.; Buck, A. K.; Reiners, C.; Verburg, F. A.

    2014-05-01

    Radioiodine scintigraphy influences staging and treatment in patients with differentiated thyroid carcinoma. The limit of detection for fractional uptake in an iodine avid focus in a scintigraphic image was determined from the number of lesion net counts and the count density of the tissue background. The count statistics were used to calculate the diagnostic activity required to elevate the signal from a lesion with a given uptake significantly above a homogeneous background with randomly distributed counts per area. The dependences of the minimal uptake and the minimal size of lesions visible in a scan on several parameters of influence were determined by linking the typical biokinetics observed in iodine avid tissue to the lesion mass and to the absorbed dose received in a radioiodine therapy. The detection limits for fractional uptake in a neck lesion of a typical patient are about 0.001% after therapy with 7000 MBq, 0.01% for activities typically administered in diagnostic assessments (74-185 MBq), and 0.1% after the administration of 10 MBq I-131. Lesions at the limit of detection in a diagnostic scan with biokinetics eligible for radioiodine therapy are small with diameters of a few millimeters. Increasing the diagnostic activity by a factor of 4 reduces the diameter of visible lesions by 25% or about 1 mm. Several other determinants have a comparable or higher influence on the limit of detection than the administered activity; most important are the biokinetics in both blood pool and target tissue and the time of measurement. A generally valid recommendation for the timing of the scan is impossible as the time of the highest probability to detect iodine avid tissue depends on the administered activity as well as on the biokinetics in the lesion and background in the individual patient.

  19. Clinical experience with recombinant human thyroid-stimulating hormone (rhTSH): whole-body scanning with iodine-131.

    PubMed

    Reiners, C; Luster, M; Lassmann, M

    1999-01-01

    Whole-body scanning (WBS) with iodine-131 (I-131) is currently used together with serum thyroglobulin (Tg) measurement in the diagnostic follow-up of well-differentiated thyroid carcinoma. One of the main disadvantages of I-131 WBS is its requirement of repeated weeks-long withdrawal of thyroid hormone suppression therapy (THST) to raise endogenous thyroid-stimulating hormone (TSH) production. This results in hypothyroidism and associated abnormalities, discomfort and morbidity. Recently, however, a series of multicentre clinical studies established the efficacy, safety, non-antigenicity, and quality of life benefits of recombinant human TSH (rhTSH, Thyrogen, thyrotropin alfa, Genzyme Corporation, Cambridge, MA, USA) in promoting radioiodine uptake and permitting sensitive I-131 WBS in patients on THST after initial therapy of well-differentiated thyroid cancer. Thus in everyday practice, rhTSH administration may in many cases supersede THST withdrawal as a preparative method for I-131 imaging. With the use of rhTSH, as whenever I-131 WBS is performed, useful and accurate imaging requires meticulous attention to good scanning practices. These include use of appropriate equipment, proper timing, sufficient scanning time, vigilance against artifacts and iodine contamination, and consideration of additional imaging in the case of ambiguous 48-hour scans. Whole-body retention of I-131 is approximately 50% greater during hypothyroidism after THST withdrawal than during euthyroidism on THST and rhTSH. Therefore, it is important to use an adequate diagnostic activity of > or =4 mCi (148 MBq) to compensate for the faster radioiodine clearance in the euthyroid state permitted by rhTSH administration. Ongoing dosimetric research eventually may provide more specific guidance regarding radioiodine activities for diagnostic, and, particularly, therapeutic purposes, with the use of rhTSH.

  20. Outpatient radioiodine therapy for thyroid cancer: a safe nuclear medicine procedure.

    PubMed

    Willegaignon, José; Sapienza, Marcelo; Ono, Carla; Watanabe, Tomoco; Guimarães, Maria Inês; Gutterres, Ricardo; Marechal, Maria Helena; Buchpiguel, Carlos

    2011-06-01

    To evaluate the dosimetric effect of outpatient radioiodine therapy for thyroid cancer in members of a patient's family and their living environment, when using iodine-131 doses reaching 7.4 GBq. The following parameters were thus defined: (a) whole-body radiation doses to caregivers, (b) the production of contaminated solid waste, and (c) radiation potential and surface contamination within patients' living quarters. In total, 100 patients were treated on an outpatient basis, taking into consideration their acceptable living conditions, interests, and willingness to comply with medical and radiation safety guidelines. Both the caregivers and the radiation dose potentiality inside patients' residences were monitored by using thermoluminescent dosimeters. Surface contamination and contaminated solid wastes were identified and measured with a Geiger-Müller detector. A total of 90 monitored individuals received a mean dose of 0.27 (±0.28) mSv, and the maximum dose registered was 1.6 mSv. The mean value for the potential dose within all living quarters was 0.31 (±0.34) mSv, and the mean value per monitored surface was 5.58 Bq/cm(2) for all the 1659 points measured. The overall production of contaminated solid wastes was at a low level, being about 3 times less than the exemption level indicated by the International Atomic Energy Agency. This study indicates that the treatment of thyroid cancer by applying radioiodine activities up to 7.4 GBq, on an outpatient basis, is a safe procedure, especially when supervised by qualified professionals. This alternative therapy should be a topic for careful discussion considering the high potential for reducing costs in healthcare and improving patient acceptance.

  1. Trends in Costs of Thyroid Disease Treatment in Denmark during 1995-2015.

    PubMed

    Møllehave, Line Tang; Linneberg, Allan; Skaaby, Tea; Knudsen, Nils; Ehlers, Lars; Jørgensen, Torben; Thuesen, Betina Heinsbæk

    2018-03-01

    Iodine fortification (IF) may contribute to changes in costs of thyroid disease treatment through changes in disease patterns. From a health economic perspective, assessment of the development in costs of thyroid disease treatment in the population is pertinent. To assess the trends in annual medicine and hospital costs of thyroid disease treatment during 1995-2015 in Denmark, i.e., before and after the introduction of mandatory IF in 2000. Information on treatments for thyroid disease (antithyroid medication, thyroid hormone therapy, thyroid surgery, and radioiodine treatment) was obtained from nationwide registers. Costs were valued at 2015 prices using sales prices for medicines and the Danish Diagnosis-Related Group (DRG) and Danish Ambulatory Grouping System (DAGS) tariffs of surgeries/radioiodine treatments. Results were adjusted for changes in population size and age and sex distribution. The total direct medicine and hospital costs of thyroid disease treatment increased from EUR ∼190,000 per 100,000 persons in 1995 to EUR ∼270,000 per 100,000 persons in 2015. This was mainly due to linearly increased costs of thyroid hormone therapy and increased costs of thyroid surgery since 2008. Costs of antithyroid medication increased slightly and transiently after IF, while costs of radioiodine treatment remained constant. Costs of thyroid hormone therapy and thyroid surgery did not follow the development in the prevalence of hypothyroidism and structural thyroid diseases observed in concurrent studies. The costs of total direct medicine and hospital costs for thyroid disease treatment in Denmark increased from 1995 to 2015. This is possibly due to several factors, e.g., changes in treatment practices, and the direct effect of IF alone remains to be estimated.

  2. Radioiodinated cholesteryl ester analogs as residualizing tracers of lipoproteins disposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeForge, L.E.

    1989-01-01

    Due to the importance of low density lipoprotein (LDL) in lipid metabolism and atherosclerosis, efforts were made to incorporate {sup 125}I-cholesteryl iopanoate ({sup 125}I-CI), a residualizing cholesteryl ester (CE) analog, into the lipid core of LDL. This preparation is potentially useful as a scintigraphically detectable tracer of LDL uptake into atheroma and tissues such as the adrenal and liver. Initial studies using a cholesterol-fed rabbit model of atherosclerosis validated the use of {sup 125}I-CI as a tracer of CE deposition. However, scintigraphy revealed considerable nonspecific {sup 125}I-CI uptake due to tissue cholesterol loading. An alternative animal model was the guineamore » pig, which responds moderately to cholesterol feeding and carries the plasma cholesterol predominantly as LDL. Dietary fat and cholesterol, coupled with chronic aortic injury caused by an indwelling catheter, resulted in lipid containing, smooth muscle cell proliferative lesions in many animals. However, further studies are necessary to fully characterize this model. In additional studies, in vitro methods for incorporating {sup 125}I-CI into LDL were examined. These included a reconstitution procedure described by Krieger et al. and a procedure involving incubation of detergent (Tween 20)-solubilized {sup 125}I-CI with plasma. Although both LDL preparations were taken up normally by cultured fibroblasts, the plasma clearance rate of reconstituted LDL was markedly abnormal in guinea pigs. In contrast, LDL labeled by the detergent method cleared from the plasma identically to a radioiodinated LDL control. Therefore, this latter procedure was also used to incorporate two novel radioiodinated cholesteryl ether analogs {sup 125}I-CI cholesteryl m-iodobenzyl ether ({sup 125}I-CIDE) and {sup 125}I-cholesteryl 12-(miodophenyl)dodecyl ether ({sup 125}I-CIDE) into LDL.« less

  3. An audit of management of differentiated thyroid cancer in specialist and non-specialist clinic settings.

    PubMed

    Kumar, H; Daykin, J; Holder, R; Watkinson, J C; Sheppard, M C; Franklyn, J A

    2001-06-01

    Thyroid cancer is the most common endocrine malignancy but is none the less rare. Some aspects of its management remain controversial. Previous audits of patient management in the United Kingdom have revealed deficiencies, especially in communication between specialists. We have audited patient management in a large university-associated teaching hospital, assessing points of good practice identified from published guidelines and reviews, and have compared findings in groups of patients managed jointly by specialists with an interest in thyroid cancer (including surgeon, endocrinologist and oncologist) with a group managed by other clinicians outside that setting. Retrospective case-note review of 205 patients with differentiated (papillary or follicular) cancer including group A (n = 134; managed in a specialist multi-disciplinary clinic setting) and group B (n = 71; managed in other clinic settings). Points of good practice investigated were adequacy of surgery, surgical complications, prescription and adequacy of T4 treatment, adequacy of monitoring by measurement of serum thyroglobulin and action taken and appropriate administration of ablative radioiodine. Deficiencies in management of the cohort as a whole were identified, including inadequate surgery and inadequate TSH suppression in approximately one-fifth of the cases. Monitoring with thyroglobulin measurements and action when serum thyroglobulin was high were also inadequate in some cases and ablative radioiodine was not given, despite being indicated in 11.7% of the cohort. Inadequate surgery and failure to administer radioiodine were less common in those managed in a specialist clinic setting than in those managed in other clinic settings. The findings highlight the need for locally agreed protocols in managing relatively rare endocrine disorders such as thyroid cancer and argue in favour of centralization of expertise and patient management in multi-disciplinary specialist clinic settings.

  4. Mutant protein of recombinant human granulocyte colony-stimulating factor for receptor binding assay.

    PubMed

    Watanabe, M; Fukamachi, H; Uzumaki, H; Kabaya, K; Tsumura, H; Ishikawa, M; Matsuki, S; Kusaka, M

    1991-05-15

    A new mutant protein of recombinant human granulocyte colony-stimulating factor (rhG-CSF) was produced for the studies on receptors for human G-CSF. The mutant protein [(Tyr1, Tyr3]rhG-CSF), the biological activity of which was almost equal to that of rhG-CSF, was prepared by the replacement of threonine-1 and leucine-3 of rhG-CSF with tyrosine. The radioiodinated preparation of the mutant protein showed high specific radioactivity and retained full biological activity for at least 3 weeks. The binding capacity of the radioiodinated ligand was compared with that of [35S]rhG-CSF. Both radiolabeled ligands showed specific binding to murine bone marrow cells. Unlabeled rhG-CSF and human G-CSF purified from the culture supernatant of the human bladder carcinoma cell line 5637 equally competed for the binding of labeled rhG-CSFs in a dose-dependent manner, demonstrating that the sugar moiety of human G-CSF made no contribution to the binding of human G-CSF to target cells. In contrast, all other colony-stimulating factors and lymphokines examined did not affect the binding. Scatchard analysis of the specific binding of both labeled ligands revealed a single class of binding site with an apparent dissociation constant (Kd) of 20-30 pM and 100-200 maximal binding sites per cell. These data indicate that the radioiodinated preparation of the mutant protein binds the same specific receptor with the same affinity as [35S]rhG-CSF. The labeled mutant protein also showed specific binding to human circulating neutrophils.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Results of preventive radioiodine therapy in euthyroid patients with history of hyperthyroidism prior to administration of amiodarone with permanent atrial fibrillation--a preliminary study.

    PubMed

    Czarnywojtek, Agata; Zgorzalewicz-Stachowiak, Małgorzata; Woliński, Kosma; Płazińska, Maria Teresa; Miechowicz, Izabela; Kwiecińska, Barbara; Czepczyński, Rafał; Królicki, Leszek; Ruchała, Marek

    2014-01-01

    Radioiodine (RAI) therapy is a standard procedure in the treatment of hyperthyroidism. However, the use of RAI in euthyroid patients requiring chronic administration of amiodarone (AM) where other antiarrhythmic drugs may lack efficacy is still controversial. The aim of this study was to assess the safety and efficacy of an AM therapy prior to treatment with radioiodine therapy in euthyroid patients with permanent atrial fibrillation (PAF), who had been treated for hyperthyroidism in the past. This was a retrospective observational study. Patients were assessed at baseline and two, six, eight, and 12 months after RAI therapy. 17 euthyroid patients with PAF were qualified to the RAI (female/male 3/14; age range 65 to 87, median 71). The patients required chronic administration of AM as a prophylaxis against sudden death. Each patient received an ablative dose of 800 MBq (22 mCi) of 131I. At baseline and during follow-up, no side effects of the therapy and no signs of drug intolerance were observed. Subclinical hyperthyroidism occurred in two (11.8%) cases after two months of RAI and five weeks of AM administration. In this situation, RAI therapy was repeated. Three patients (17.6%) after six months, and another two (11.8%) after eight months, required an additional dose of 131I due to amiodarone-induced thyrotoxicosis (AIT). Twelve patients (70.6%) returned to spontaneous sinus rhythm within two months. Fourteen patients (82.4%) had sinus rhythm during follow-up after six and 12 months of treatment. Preventive RAI in euthyroid (but previously hyperthyroid) patients with PAF before administration of AM may be the method of choice. This is particularly important for patients who will require permanent AM administration as a life-saving drug.

  6. Laser ablation and 131-iodine: a 24-month pilot study of combined treatment for large toxic nodular goiter.

    PubMed

    Chianelli, M; Bizzarri, G; Todino, V; Misischi, I; Bianchini, A; Graziano, F; Guglielmi, R; Pacella, C M; Gharib, H; Papini, E

    2014-07-01

    It is normally recognized that the preferred treatment in large toxic thyroid nodules should be thyroidectomy. The aim of the study was to assess the efficacy of combined laser ablation treatment (LAT) and radioiodine 131 (131I) treatment of large thyroid toxic nodules with respect to rapidity of control of local symptoms, of hyperthyroidism, and of reduction of administered 131I activity in patients at refusal or with contraindications to surgery. We conducted a pilot study at a single center specializing in thyroid care. Fifteen patients were treated with LAT, followed by 131I (group A), and a series of matched consecutive patients were treated by 131I only (group B). Laser energy was delivered with an output power of 3 W (1800 J per fiber per treatment) through two 75-mm, 21-gauge spinal needles. Radioiodine activity was calculated to deliver 200 Gy to the hyperfunctioning nodule. Thyroid function, thyroid peroxidase antibody, thyroglobulin antibody, ultrasound, and local symptoms were measured at baseline and up to 24 months. Nodule volume reduction at 24 months was: 71.3 ± 13.4 vs 47.4 ± 5.5%, group A (LAT+131I) vs group B (131I), respectively; P < .001). In group A (LAT+131I), a reduction in radioiodine-administered activity was obtained (-21.1 ± 8.1%). Local symptom score demonstrated a more rapid reduction in group A (LAT+131I). In three cases, no 131I treatment was needed after LAT. In this pilot study, combined LAT/131I treatment induced faster and greater improvement of local and systemic symptoms compared to 131I only. This approach seems a possible alternative to thyroidectomy in patients at refusal of surgery.

  7. The utility of radioiodine uptake and thyroid scintigraphy in the diagnosis and management of hyperthyroidism.

    PubMed

    Okosieme, O E; Chan, D; Price, S A; Lazarus, J H; Premawardhana, L D K E

    2010-01-01

    The value and practice of thyroid radionuclide imaging in the diagnosis and management of hyperthyroidism is unsettled. Our objectives were to determine the influence of thyroid uptake and scintigraphy on the diagnosis of hyperthyroidism and the prediction of outcome following radioiodine therapy. We reviewed records and scintigraphic studies on 881 hyperthyroid patients carried out between 2000 and 2007. The agreement between the clinical and scintigraphic diagnosis was evaluated by kappa statistics. We determined the relationship between 4-h (123)I uptake and the outcome of (131)I treatment in 626 patients. A multiple logistic regression model was used to determine variables influencing treatment outcome in 1 year. The diagnostic categories were Graves' disease (GD, n = 383), toxic multinodular goitre (n = 253), solitary toxic nodule (n = 164) and Graves' disease coexisting with nodules (n = 81). The mean age of the patients was 58 +/- 17, (M:F 160:721). There was good agreement between clinical and scintigraph diagnosis (K = 0.60, 95% CI 0.57-0.64, P < 0.001); and they were correctly matched in 74%; mismatched in 6% and indeterminate in 20% of patients. Treatment outcome was not associated with scintigraph diagnosis (P = 0.98) or radioiodine uptake at 4 h (P = 0.2). The use of antithyroid medications before treatment predicted treatment failure (odds ratio 2.0, 95% CI 1.2-3.6, P = 0.01). Thyroid scintigraphy and uptake studies did not influence diagnosis or treatment outcomes in most cases of hyperthyroidism. Our findings in this retrospective study do not justify their routine use. Selective scanning will reduce cost and exposure to radioisotopes without compromising diagnostic accuracy or treatment outcomes.

  8. Twenty-five years after Chernobyl: outcome of radioiodine treatment in children and adolescents with very high-risk radiation-induced differentiated thyroid carcinoma.

    PubMed

    Reiners, Christoph; Biko, Johannes; Haenscheid, Heribert; Hebestreit, Helge; Kirinjuk, Stalina; Baranowski, Oleg; Marlowe, Robert J; Demidchik, Ewgeni; Drozd, Valentina; Demidchik, Yuri

    2013-07-01

    After severe reactor emergencies with release of radioactive iodine, elevated thyroid cancer risk in children and adolescents is considered the main health consequence for the population exposed. We studied thyroid cancer outcome after 11.3 years' median follow-up in a selected, very high-risk cohort, 234 Chernobyl-exposed Belarusian children and adolescents undergoing postsurgical radioiodine therapy (RIT) in Germany. Cumulatively 100 children with or (without; n = 134) distant metastasis received a median 4 (2) RITs and 16.9 (6.6) GBq, corresponding to 368 (141) MBq/kg iodine-131. Outcomes were response to therapy and disease status, mortality, and treatment toxicity. Of 229 patients evaluable for outcome, 147 (64.2%) attained complete remission [negative iodine-131 whole-body scan and TSH-stimulated serum thyroglobulin (Tg) < 1 μg /L], 69 (30.1%) showed nearly complete remission (complete response, except stimulated Tg 1-10 μg/L), and 11 (4.8%) had partial remission (Tg > 10 μg/L, decrease from baseline in radioiodine uptake intensity in ≥ 1 focus, in tumor volume or in Tg). Except for 2 recurrences (0.9%) after partial remission, no recurrences, progression, or disease-specific mortality were noted. One patient died of lung fibrosis 17.5 years after therapy, 2 of apparently thyroid cancer-unrelated causes. The only RIT side effect observed was pulmonary fibrosis in 5 of 69 patients (7.2%) with disseminated lung metastases undergoing intensive pulmonary surveillance. Experience of a large, very high-risk pediatric cohort with radiation-induced differentiated thyroid carcinoma suggests that even when such disease is advanced and initially suboptimally treated, response to subsequent RIT and final outcomes are mostly favorable.

  9. NDSC Lidar Intercomparisons and Validation: OPAL and MLO3 Campaigns in 1995

    NASA Technical Reports Server (NTRS)

    McDermid, Stuart; McGee, Thomas J.; Stuart, Daan P. J.

    1996-01-01

    The Network for the Detection of Stratospheric Change (NDSC) has developed and adopted a Validation Policy in order to ensure that the results submitted and stored in its archives are of a known, high quality. As a part of this validation policy, blind instrument intercomparisons are considered an essential element in the certification of NDSC instruments and a specific format for these campaigns has been recommended by the NDSC-Steering Committee.

  10. The April 1992 and November 1992 radon intercomparisons at EML

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisenne, I.M.; George, A.C.; Perry, P.M.

    1993-07-01

    The Environmental Measurements Laboratory hosted two intercomparison exercises in Calendar Year 1992. Thirty-two groups, including US federal facilities, US Department of Energy`s Office of Health and Environmental Research contractors, national and state laboratories, and universities and foreign institutions, participated in these exercises. The majority of the participants` results were within {plus_minus}10% of the EML value at radon concentrations of 2075 and 1650 Bq m{sup {minus}3}.

  11. International round-robin inter-comparison of dye-sensitized and crystalline silicon solar cells

    NASA Astrophysics Data System (ADS)

    Chen, Chia-Yuan; Ahn, Seung Kyu; Aoki, Dasiuke; Kokubo, Junichi; Yoon, Kyung Hoon; Saito, Hidenori; Lee, Kyung Sik; Magaino, Shinichi; Takagi, Katsuhiko; Lin, Ling-Chuan; Lee, Kun-Mu; Wu, Chun-Guey; Zhou, Hong; Igari, Sanekazu

    2017-02-01

    An international round-robin inter-comparison of the spectral responsivity (SR) and current-voltage (I-V) characteristics for dye-sensitized solar cells (DSCs) and crystalline silicon solar cells is reported for the first time. The crystalline silicon cells with various spectral responsivities were also calibrated by AIST to validate this round-robin activity. On the basis of the remarkable consistency in Pmax (within ±1.4% among participants) and Isc (within ±1.2% compared to the primary calibration of AIST) of the silicon specimens, the discrepancy in the SR and photovoltaic parameters of five DSCs among three national laboratories can be verified and diagnosed. Recommendations about sample packages, SR and I-V measurement methods as well as the inter-comparison protocol for improving the performance characterization of the mesoscopic DSCs are presented according to the consolidated data and the experience of the participants.

  12. The global gridded crop model intercomparison: Data and modeling protocols for Phase 1 (v1.0)

    DOE PAGES

    Elliott, J.; Müller, C.; Deryng, D.; ...

    2015-02-11

    We present protocols and input data for Phase 1 of the Global Gridded Crop Model Intercomparison, a project of the Agricultural Model Intercomparison and Improvement Project (AgMIP). The project consist of global simulations of yields, phenologies, and many land-surface fluxes using 12–15 modeling groups for many crops, climate forcing data sets, and scenarios over the historical period from 1948 to 2012. The primary outcomes of the project include (1) a detailed comparison of the major differences and similarities among global models commonly used for large-scale climate impact assessment, (2) an evaluation of model and ensemble hindcasting skill, (3) quantification ofmore » key uncertainties from climate input data, model choice, and other sources, and (4) a multi-model analysis of the agricultural impacts of large-scale climate extremes from the historical record.« less

  13. Intercomparison and interpretation of climate feedback processes in 19 atmospheric general circulation models

    NASA Technical Reports Server (NTRS)

    Cess, R. D.; Potter, G. L.; Blanchet, J. P.; Boer, G. J.; Del Genio, A. D.

    1990-01-01

    The present study provides an intercomparison and interpretation of climate feedback processes in 19 atmospheric general circulation models. This intercomparison uses sea surface temperature change as a surrogate for climate change. The interpretation of cloud-climate interactions is given special attention. A roughly threefold variation in one measure of global climate sensitivity is found among the 19 models. The important conclusion is that most of this variation is attributable to differences in the models' depiction of cloud feedback, a result that emphasizes the need for improvements in the treatment of clouds in these models if they are ultimately to be used as reliable climate predictors. It is further emphazied that cloud feedback is the consequence of all interacting physical and dynamical processes in a general circulation model. The result of these processes is to produce changes in temperature, moisture distribution, and clouds which are integrated into the radiative response termed cloud feedback.

  14. Progress in high-dose radiation dosimetry. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ettinger, K.V.; Nam, J.W.; McLaughlin, W.L.

    1981-01-01

    The last decade has witnessed a deluge of new high-dose dosimetry techniques and expended applications of methods developed earlier. Many of the principal systems are calibrated by means of calorimetry, although production of heat is not always the final radiation effect of interest. Requirements for a stable and reliable transfer dose meters have led to further developments of several important high-dose systems: thermoluminescent materials, radiochromic dyes, ceric-cerous solutions analyzed by high-frequency oscillometry. A number of other prospective dosimeters are also treated in this review. In addition, an IAEA program of high-dose intercomparison and standardization for industrial radiation processing is described.

  15. A Practitioners Perspective on Verification

    NASA Astrophysics Data System (ADS)

    Steenburgh, R. A.

    2017-12-01

    NOAAs Space Weather Prediction Center offers a wide range of products and services to meet the needs of an equally wide range of customers. A robust verification program is essential to the informed use of model guidance and other tools by both forecasters and end users alike. In this talk, we present current SWPC practices and results, and examine emerging requirements and potential approaches to satisfy them. We explore the varying verification needs of forecasters and end users, as well as the role of subjective and objective verification. Finally, we describe a vehicle used in the meteorological community to unify approaches to model verification and facilitate intercomparison.

  16. A strawman SLR program plan for the 1990s

    NASA Technical Reports Server (NTRS)

    Degnan, John J.

    1994-01-01

    A series of programmatic and technical goals for the satellite laser ranging (SLR) network are presented. They are: (1) standardize the performance of the global SLR network; (2) improve the geographic distribution of stations; (3) reduce costs of field operations and data processing; (4) expand the 24 hour temporal coverage to better serve the growing constellation of satellites; (5) improve absolute range accuracy to 2 mm at key stations; (6) improve satellite force, radiative propagation, and station motion models and investigate alternative geodetic analysis techniques; (7) support technical intercomparison and the Terrestrial Reference Frame through global collocations; (8) investigate potential synergisms between GPS and SLR.

  17. Imaging agent and method of use

    DOEpatents

    Wieland, D.M.; Brown, L.E.; Beierwaltes, W.H.; Wu, J.L.

    1986-04-22

    A new radiopharmaceutical composition for use in nuclear medicine comprises a radioiodinated meta-iodobenzylguanidine. The composition is used as an imaging agent for the heart, adrenal medulla, and tumors of the adrenal medulla and can be used for treatment of tumors of the adrenal medulla. No Drawings

  18. NEVADA TEST SITE EXPERIMENTAL FARM: SUMMARY REPORT 1963-1981

    EPA Science Inventory

    This report summarizes the findings from experiments conducted at the Experimental Dairy Farm located on the Nevada Test Site. These experiments included the air-forage-cow-milk transport of the radioiodines, and the metabolism and milk transfer of other fission products and seve...

  19. Iodine Symporter Targeting with 124I/131I Theranostics.

    PubMed

    Nagarajah, James; Janssen, Marcel; Hetkamp, Philipp; Jentzen, Walter

    2017-09-01

    Theranostics, a modern approach combining therapeutics and diagnostics, is among the most promising concepts in nuclear medicine for optimizing and individualizing treatments for many cancer entities. Theranostics has been used in clinical routines in nuclear medicine for more than 60 y-as 131 I for diagnostic and therapeutic purposes in thyroid diseases. In this minireview, we provide a survey of the use of 2 different radioiodine isotopes for targeting the sodium-iodine symporter in thyroid cancer and nonthyroidal neoplasms as well as a brief summary of theranostics for neuroendocrine neoplasms and metastatic castration-refractory prostate cancer. In particular, we discuss the role of 124 I-based dosimetry in targeting of the sodium-iodine symporter and describe the clinical application of 124 I dosimetry in a patient who had radioiodine-refractory thyroid cancer and who underwent a redifferentiation treatment with the mitogen-activated extracellular signal-related kinase kinase inhibitor trametinib. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  20. Muscarinic cholinergic receptor binding: in vivo depiction using single photon emission computed tomography and radioiodinated quinuclidinyl benzilate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drayer, B.; Jaszczak, R.; Coleman, E.

    1982-06-01

    An attempt was made to characterize, in vivo, specific binding to the muscarinic cholinergic receptor in the calf using the radioiodinated ligand quinuclidinyl benzilate (/sup 123/I-OH-QNB) and single photon detection emission computed tomography (SPECT). The supratentorial brain activity was significantly increased after the intravenous infusion of /sup 123/I-OH-QNB as compared to free /sup 123/I. Scopolamine, a muscarinic cholinergic receptor antagonist, decreased the measured brain activity when infused prior to /sup 123/I-OH-QNB consistent with pharmacologic blockade of specific receptor binding. Quantitative in vitro tissue distribution studies obtained following SPECT imaging were consistent with regionally distinct specific receptor binding in the striatummore » and cortical gray matter, nonspecific binding in the cerebellum, and pharmacologic blockade of specific binding sites with scopolamine. Although /sup 123/I-OH-QNB is not the ideal radioligand, our limited success will hopefully encourage the development of improved binding probes for SPECT imaging and quantitation.« less

  1. Tethered Hsp90 Inhibitors Carrying Optical or Radioiodinated Probes Reveal Selective Internalization of Ectopic Hsp90 in Malignant Breast Tumor Cells

    PubMed Central

    Barrott, Jared J.; Hughes, Philip F.; Osada, Takuya; Yang, Xiao-Yi; Hartman, Zachary C.; Loiselle, David R.; Spector, Neil L.; Neckers, Len; Rajaram, Narasimhan; Hu, Fangyao; Ramanujam, Nimmi; Vaidyanathan, Ganesan; Zalutsky, Michael R.; Lyerly, H. Kim; Haystead, Timothy A.

    2013-01-01

    Summary Hsp90 inhibitors have demonstrated unusual selectivity for tumor cells despite its ubiquitous expression. This phenomenon has remained unexplained but could be influenced by ectopically expressed Hsp90 in tumors. We have synthesized novel Hsp90 inhibitors that can carry optical or radioiodinated probes via a PEG tether. We show that these tethered inhibitors selectively recognize cells expressing ectopic Hsp90 and become internalized. The internalization process is blocked by Hsp90 antibodies, suggesting that active cycling of the protein is occurring at the plasma membrane. In mice, we show exquisite accumulation of the fluor-tethered versions within breast tumors at very sensitive levels. Cell-based assays with the radiolabeled version showed picomolar detection in cells that express ectopic Hsp90. Our findings show that fluor-tethered or radiolabeled inhibitors targeting ectopic Hsp90 can be used to detect breast cancer malignancies through non-invasive imaging. PMID:24035283

  2. Improved radioimmunotherapy of hematologic malignancies. [Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Press, O.W.

    This research project proposes to develop novel new approaches of improving the radioimmunodetection and radioimmunotherapy of malignancies by augmenting retention of radioimmunoconjugates by tumor cells. The approaches shown to be effective in these laboratory experiments will subsequently be incorporated into out ongoing clinical trials in patients. Specific project objectives include: to study the rates of endocytosis, intracellular routing, and metabolic degradation of radiolabeled monoclonal antibodies targeting tumor-associated antigens on human leukemia and lymphoma cells; To examine the effects of lysosomotropic amines (e.g. chloroquine, amantadine), carboxylic ionophores (monensin, nigericin), and thioamides (propylthiouracil), on the retention of radiolabeled MoAbs by tumor cells;more » to examine the impact of newer radioiodination techniques (tyramine cellobiose, paraiodobenzoyl) on the metabolic degradation of radioiodinated antibodies; to compare the endocytosis, intracellular routing, and degradation of radioimmunoconjugates prepared with different radionuclides ({sup 131}Iodine, {sup 111}Indium, {sup 90}Yttrium, {sup 99m}Technetium, {sup 186}Rhenium); and to examine the utility of radioimmunoconjugates targeting oncogene products for the radioimmunotherapy and radioimmunoscintigraphy of cancer.« less

  3. Improved radioimmunotherapy of hematologic malignancies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Press, O.W.

    This research project proposes to develop novel new approaches of improving the radioimmunodetection and radioimmunotherapy of malignancies by augmenting retention of radioimmunoconjugates by tumor cells. The approaches shown to be effective in these laboratory experiments will subsequently be incorporated into out ongoing clinical trials in patients. Specific project objectives include: to study the rates of endocytosis, intracellular routing, and metabolic degradation of radiolabeled monoclonal antibodies targeting tumor-associated antigens on human leukemia and lymphoma cells; To examine the effects of lysosomotropic amines (e.g. chloroquine, amantadine), carboxylic ionophores (monensin, nigericin), and thioamides (propylthiouracil), on the retention of radiolabeled MoAbs by tumor cells;more » to examine the impact of newer radioiodination techniques (tyramine cellobiose, paraiodobenzoyl) on the metabolic degradation of radioiodinated antibodies; to compare the endocytosis, intracellular routing, and degradation of radioimmunoconjugates prepared with different radionuclides ({sup 131}Iodine, {sup 111}Indium, {sup 90}Yttrium, {sup 99m}Technetium, {sup 186}Rhenium); and to examine the utility of radioimmunoconjugates targeting oncogene products for the radioimmunotherapy and radioimmunoscintigraphy of cancer.« less

  4. Red cell changes in hyperthyroidism.

    PubMed

    How, J; Davidson, R J; Bewsher, P D

    1979-10-01

    The Coulter 'S' red cell profile was studied prospectively in 100 untreated non-anaemic hyperthyroid patients and followed up in 52 of them until they had become euthyroid with radio-iodine or carbimazole treatment. Serial haematological data were also obtained in 23 hyperthyroid patients during treatment with beta-adrenoreceptor blocking drug alone. The most significant finding was a low mean corpuscular volume (MCV) which was invariably present throughout the hyperthyroid state. Treatment with beta-adrenoreceptor blocking drugs did not significantly alter any of the red cell parameters. On the other hand, the MCV increased and was restored to normal with radio-iodine or carbimazole treatment although there was a lag period of about 6--8 weeks between achieving the euthyroid state and the normalisation of this red cell index. While none of the patients were aneaemic, the haemoglobin level rose significantly following effective anti-thyroid treatment. It is suggested that measurement of the MCV may have a useful role in the diagnosis of hyperthyroidism. 2 possible mechanisms leading to the observed red cell changes in hyperthyroidism are postulated.

  5. Synchronous papillary carcinoma in thyroglossal duct cyst and thyroid gland: case report and review of literature.

    PubMed

    Cherian, Mathew Pynumootil; Nair, Balakrishnan; Thomas, Shaji; Somanathan, Thara; Sebastian, Paul

    2009-10-01

    We report a rare case of synchronous occurrence of thyroglossal duct cyst carcinoma and thyroid carcinoma and discuss its management in detail. A 59-year-old woman was clinically diagnosed to have a thyroglossal duct cyst and a solitary nodule. Fine-needle aspiration cytology revealed a papillary carcinoma in the thyroglossal duct cyst and a colloid in the thyroid nodule. Sistrunk's procedure along with a total thyroidectomy was performed followed by postoperative radioiodine ablation. Histopathologic examination revealed thyroglossal duct cyst carcinoma and bilateral foci of papillary carcinoma in the thyroid gland. She has remained free of disease on follow-up. Most cancers arising in thyroglossal duct cysts are of low risk, and Sistrunk's procedure is an adequate treatment for such cancers. However, for synchronously occurring cancers of the thyroglossal duct cyst and thyroid gland, or high-risk thyroglossal duct cyst cancers, more aggressive treatment comprising total thyroidectomy, Sistrunk's procedure, and radioiodine therapy is indicated. (c) 2009 Wiley Periodicals, Inc.

  6. Sequestration of radioactive iodine in silver-palladium phases in commercial spent nuclear fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buck, Edgar C.; Mausolf, Edward J.; McNamara, Bruce K.

    Radioactive iodine is the Achilles’ heel in the design for the safe geological disposal of spent UO2 nuclear fuel. Iodine’s high solubility and anticipated instant release during waste package compromise jeopardize performance assessment calculations. However, dissolution studies have indicated that the instant release fraction (IRF) of radioiodine (I) does not correlate with increasing fuel burn-up. In fact, there is a peak in the release iodine at around 50-60 Mwd/kgU and with increasing burn-up the instant release of iodine decreases. Detailed electron microscopy analysis of high burn-up fuel (~80 MWd/kgU) has revealed the presence of (Pd,Ag)(I,Br) nano-particles. As UO2 fuels aremore » irradiated, the Ag and Pd content increases, from 239Pu fission, enabling radioiodine to be retained. The occurrence of these phases in nuclear fuels may have significant implications for the long-term behavior of iodine.« less

  7. Facile Fabrication of Nanofibrillated Chitin/Ag2O Heterostructured Aerogels with High Iodine Capture Efficiency.

    PubMed

    Gao, Runan; Lu, Yun; Xiao, Shaoliang; Li, Jian

    2017-06-27

    Nanofibrillated chitin/Ag 2 O aerogels were fabricated for radioiodine removal. Chitin was first fabricated into nanofibers with abundant acetyl amino groups (-NHCOCH 3 ) on the surface. Then, highly porous chitin nanofiber (ChNF) aerogels were obtained via freeze-drying. The ChNF aerogels exhibited a low bulk density of 2.19 mg/cm 3 and a high specific surface area of 179.71 m 2 /g. Ag 2 O nanoparticles were evenly anchored on the surfaces of ChNF scaffolds via strong interactions with -NHCOCH 3 groups, subsequently yielding Ag 2 O@ChNF heterostructured aerogels. The composites were used as efficient absorbents to remove radioiodine anions from water and capture a high amount of I 2 vapor in the forms of AgI and iodine molecules. The adsorption capacity of the composite monoliths can reach up to 2.81 mmol/g of I - anions. The high adsorbability of the composite monolithic aerogel signifies its potential applications in radioactive waste disposal.

  8. Microbial Transformation of Iodine: From Radioisotopes to Iodine Deficiency.

    PubMed

    Yeager, Chris M; Amachi, Seigo; Grandbois, Russell; Kaplan, Daniel I; Xu, Chen; Schwehr, Kathy A; Santschi, Peter H

    2017-01-01

    Iodine is a biophilic element that is important for human health, both as an essential component of several thyroid hormones and, on the other hand, as a potential carcinogen in the form of radioiodine generated by anthropogenic nuclear activity. Iodine exists in multiple oxidation states (-1, 0, +1, +3, +5, and +7), primarily as molecular iodine (I 2 ), iodide (I - ), iodate [Formula: see text] , or organic iodine (org-I). The mobility of iodine in the environment is dependent on its speciation and a series of redox, complexation, sorption, precipitation, and microbial reactions. Over the last 15years, there have been significant advances in iodine biogeochemistry, largely spurred by renewed interest in the fate of radioiodine in the environment. We review the biogeochemistry of iodine, with particular emphasis on the microbial processes responsible for volatilization, accumulation, oxidation, and reduction of iodine, as well as the exciting technological potential of these fascinating microorganisms and enzymes. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Free Radicals and Reactive Intermediates for the SAGE III Ozone Loss and Validation Experiment (SOLVE) Mission

    NASA Technical Reports Server (NTRS)

    Anderson, James G.

    2001-01-01

    This grant provided partial support for participation in the SAGE III Ozone Loss and Validation Experiment. The NASA-sponsored SOLVE mission was conducted Jointly with the European Commission-sponsored Third European Stratospheric Experiment on Ozone (THESEO 2000). Researchers examined processes that control ozone amounts at mid to high latitudes during the arctic winter and acquired correlative data needed to validate the Stratospheric Aerosol and Gas Experiment (SAGE) III satellite measurements that are used to quantitatively assess high-latitude ozone loss. The campaign began in September 1999 with intercomparison flights out of NASA Dryden Flight Research Center in Edwards. CA. and continued through March 2000. with midwinter deployments out of Kiruna. Sweden. SOLVE was co-sponsored by the Upper Atmosphere Research Program (UARP). Atmospheric Effects of Aviation Project (AEAP). Atmospheric Chemistry Modeling and Analysis Program (ACMAP). and Earth Observing System (EOS) of NASA's Earth Science Enterprise (ESE) as part of the validation program for the SAGE III instrument.

  10. Neutron cross section standards and instrumentation. Annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wasson, O.A.

    The objective of this interagency program is to provide accurate neutron interaction measurements for the US Department of Energy nuclear programs which include waste disposal, fusion, safeguards, defense, fission, and personnel protection. These measurements are also useful to other energy programs which indirectly use the unique properties of the neutron for diagnostic and analytical purposes. The work includes the measurement of reference cross sections and related neutron data employing unique facilities and capabilities at NIST and other laboratories as required; leadership and participation in international intercomparisons and collaborations; the preservation of standard reference deposits and the development of improved neutronmore » detectors and measurement methods. A related and essential element of the program is critical evaluation of neutron interaction data including international coordinations. Data testing of critical data for important applications is included. The program is jointly supported by the Department of Energy and the National Institute of Standards and Technology. This report from the National Institute of Standards and Technology contains a summary of the accomplishments of the Neutron Cross Section Standards and Instrumentation Project during the third year of this three-year interagency agreement. The proposed program and required budget for the following three years are also presented. The program continues the shifts in priority instituted in order to broaden the program base.« less

  11. Inter-comparison between AIRS and IASI through Retrieved Parameters

    NASA Technical Reports Server (NTRS)

    Zhou, Daniel K.; Larar, Allen M.; Smith, William L.; Taylor, Jonathan P.; Schluessel, Peter; Strow, L. Larrabee; Mango, Steve

    2008-01-01

    A State-of-the-art retrieval algorithm dealing with all-weather conditions has been applied to satellite/aircraft instruments retrieving cloud/surface and atmospheric conditions. High quality retrievals have been achieved from IASI data. Surface, cloud, and atmospheric structure and variation are well captured by IASI measurements and/or retrievals. The same retrieval algorithm is also applied to AIRS for retrieval inter-comparison. Both AIRS and IASI have a similar FOV size but AIRS has a higher horizontal resolution. AIRS data can be interpolated to IASI horizontal resolution for inter-comparison at the same geophysical locations, however a temporal variation between AIRS and IASI observations need to be considered. JAIVEx has employed aircraft to obtain the atmospheric variation filling the temporal gap between two satellites. First results show that both AIRS and IASI have a very similar vertical resolving power, atmospheric conditions are well captured by both instruments, and radiances are well calibrated. AIRS data shown in retrievals (e.g., surface emissivity and moisture) have a relatively higher noise level. Since the this type of retrieval is very sensitive to its radiance quality, retrieval products inter-comparison is an effective way to identify/compare their radiance quality, in terms of a combination of spectral resolution and noise level, and to assess instrument performance. Additional validation analyses are needed to provide more-definitive conclusions.

  12. AIRS Obs4MIPs V2 data set

    NASA Astrophysics Data System (ADS)

    Tian, B.

    2017-12-01

    The Coupled Model Intercomparison Project (CMIP) has become a central element of national and international assessments of climate change. The CMIP Phase 6 (CMIP6) model experiments will be the foundation for the Intergovernmental Panel on Climate Change (IPCC) Sixth Assessment Report (AR6), scheduled for publication around 2021. To increase the fidelity of the IPCC AR6, the CMIP6 model experiments need rigorous evaluation. The "Observations for Model Intercomparison Projects" (Obs4MIPs) collects, organizes and publishes various well-established satellite data sets for CMIP model evaluation. The Atmospheric Infrared Sounder (AIRS) and Advanced Microwave Sounding Unit (AMSU), the NASA's temperature and humidity sounding system on the Aqua satellite, has provided over a decade-long high-quality tropospheric temperature and moisture sounding data. Under the current support of the NASA Data for Operation and Assessment (NDOA) program, we are generating and publishing the AIRS Obs4MIPs V2 data set including the monthly mean tropospheric air temperature, specific humidity, and relative humidity profiles from September 2002 to September 2016. This will provide the latest AIRS data in Obs4MIPs and assist the climate modeling community to better use the AIRS data for CMIP (including CMIP3, CMIP5, and CMIP6) model evaluation. In this presentation, we will discuss the AIRS Obs4MIPs V2 data set and their possible use for CMIP6 climate model evaluation.

  13. Radioiodine remnant ablation in differentiated thyroid cancer after combined endogenous and exogenous TSH stimulation.

    PubMed

    Vrachimis, A; Schober, O; Riemann, B

    2012-01-01

    Radioiodine remnant ablation (RRA) after (near-)total thyroidectomy (TE) is a key element in patients with differentiated thyroid cancer (DTC). The use of exogenous TSH stimulation (rhTSH) prior to RRA has shown promising results as compared to conventional thyroid hormone withdrawal (THW). As yet, the efficacy of RRA after brief THW and single rhTSH administration has not been assessed. The study sample comprised 147 patients with DTC referred to our center between May 2008 and September 2010. All patients received TE with subsequent RRA. None of these 147 patients had evidence of distant metastasis. 93 patients had endogenous TSH stimulation 4-5 weeks after surgery (group I) and twenty-six received two rhTSH injections (group II). 28 patients were treated with a single rhTSH injection after a brief THW (group III). RRA-Efficacy was assessed three months after therapy by diagnostic whole-body scan and measurement of the tumour marker thyroglobulin (Tg) under TSH stimulation. Three categories of success were defined for remnant ablation. Based on the definition of successful remnant ablation no visible uptake and a Tg ≤ 2.0 ng/ml (category 1) was seen in 62/93 patients in group I, in 17/26 patients in group II (p = n.s.) and in 12/28 patients in group III (p < 0.05). Visible radioiodine uptake and a Tg ≤ 2.0 ng/ml (category 2) was seen in 16/28 patients of group III and thus significantly more frequent than in group I (28/93 patients) (p < 0.01). However, patients in group III (16/28 patients) and group II (8/26 patients) showed no significant difference in this category (p = n.s.). Visible radioiodine uptake and a Tg > 2.0 ng/ml (category 3) was found in 3/93 patients in group I and 1/26 patients in group II but in no patient in group III. The third strategy of remnant ablation using a single injection of rhTSH after a brief THW period resulted in a significant higher rate of patients with residual uptake in the thyroid bed and a Tg level below 2 ng/ml three months after remnant ablation in comparison to THW. However, the overall efficacy of the third protocol was not significantly different as compared to two rhTSH injections. Under the aspect of the supply shortage of rhTSH the combined endogenous and exogenous TSH stimulation may be an attractive alternative for remnant ablation in differentiated thyroid cancer.

  14. ACIX: Atmospheric Correction Inter-comparison Exercise

    NASA Astrophysics Data System (ADS)

    Doxani, Georgia; Gascon, Ferran; Vermote, Éric; Roger, Jean-Claude

    2017-04-01

    The free and open data access policy to Sentinel-2 (S-2) and Landsat-8 (L-8) satellite imagery has stimulated the development of atmospheric correction (AC) processors for generating Bottom-of-Atmosphere (BOA) products. Several entities have started to generate (or plan to generate in the short term) BOA reflectance products at global scale for S-2 and L-8 missions. To this end, the European Space Agency (ESA) and NASA are organizing an exercise on AC processors inter-comparison. The results of the exercise are expected to point out the strengths and weaknesses, as well as communalities and discrepancies of various AC processors, in order to suggest and define ways for their further improvement. In particular, 13 atmospheric processors from five different countries participate in ACIX with the aim to inter-compare their performance when applied to L-8 and S-2 data. A protocol describing the inter-comparison process and the test dataset, which is based on the AERONET sites, will be presented. The protocol has been defined according to what was agreed among the participants during the 1st ACIX workshop held in June 2016. It includes the comparison of aerosol optical thickness and water vapour products of the processors with the AERONET measurements. Moreover, concerning the surface reflectances, the protocol describes the inter-comparison among the processors, as well as the comparison with the MODIS surface reflectance and with a reference surface reflectance product. Such a reference product will be obtained using the AERONET characterization of the aerosol (size distribution and refractive indices) and an accurate radiative transfer code. The inter-comparison outcomes will be presented and discussed among the participants in the 2nd ACIX workshop, which will be held on 11-12 April 2017 (ESRIN/ESA). The proposed presentation is an opportunity for the user community to be informed for the first time about the ACIX results and conclusions.

  15. NOAA national status and trends program eleventh round intercomparison exercise results for trace metals in marine sediments and biological tissues. National status and trends program for marine environmental quality: Technical memo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willie, S.

    1997-12-01

    A total of thirty-nine participants were included in the exercise, including OAA, USEPA, state, Australian, Canadian, Mexican and Argentinean laboratories. Two samples were sent by NRC to each participant, and contaminated marine sediment from Esquimalt harbor in British Columbia and a freeze-dried oyster tissue. Laboratories were also asked to analyze two certified reference materials (CRMs) MESS-2 and CRM 2976. The elements to be determined were Al, Cr, Fe, Ni, Cu, Zn, As, Se, Ag, Cd, Sn, Hg and Pb for both matrices, plus Be, Si, Mn, Sb and Tl for the sediments. An accepted mean and confidence interval was calculatedmore » for each analyte in the two unknown samples, laboratory biases were identified and an overall rating of superior, good, fair or others were assigned to each laboratory.« less

  16. Raman LIDAR for UHECR experiments: an overview of the L'Aquila (Italy) lidar station experience for the retrieval of quality-assured data

    NASA Astrophysics Data System (ADS)

    Iarlori, Marco; Rizi, Vincenzo; D'Amico, Giuseppe; Freudenthaler, Volker; Wandinger, Ulla; Grillo, Aurelio

    L'Aquila (Italy) lidar station is part of the EARLINET (European Aerosol Research Lidar Network) since its beginning in the 2000. In the EARLINET community great efforts are devoted to the quality-assurance of the aerosol optical properties inserted in the database. To this end, each lidar station performed intercomparisons with reference instruments, a series of internal hardware checks in order to assess the quality of their instruments and exercises to test the algorithms used to retrieve the aerosol optical parameters. In this paper we give an overview of our experience within EARLINET qualityassurance (QA) program, which was adopted for the Raman lidar (RL) operated in the AUGER Observatory. This program could be systematically adopted for the lidar systems needed for the current and upcoming UHECR experiments, like CTA (Cherenkov Telescope Array).

  17. ATHLI16: the ATHens Lidar Intercomparison campaign

    NASA Astrophysics Data System (ADS)

    Amodeo, Aldo; D'Amico, Giuseppe; Giunta, Aldo; Papagiannopoulos, Nikolaos; Papayannis, Alex; Argyrouli, Athina; Mylonaki, Maria; Tsaknakis, Georgios; Kokkalis, Panos; Soupiona, Ourania; Tzanis, Chris

    2018-04-01

    The results of the ATHLI16 (ATHens Lidar Intercomparison) campaign, held in Athens from 26/09 to 07/10 2016 are presented. The campaign was performed within the Lidar Calibration Centre activities (EU H2020 ACTRIS-2 project) to assess the performance of the EOLE lidar system (NTUA, Athens, Greece), operating within EARLINET, by comparing against the EARLINET reference lidar system MUSA (CNR-IMAA, Potenza, Italy). For both lidars only products retrieved by the EARLINET Single Calculus Chain have been compared.

  18. Intercomparison of methods for coincidence summing corrections in gamma-ray spectrometry--part II (volume sources).

    PubMed

    Lépy, M-C; Altzitzoglou, T; Anagnostakis, M J; Capogni, M; Ceccatelli, A; De Felice, P; Djurasevic, M; Dryak, P; Fazio, A; Ferreux, L; Giampaoli, A; Han, J B; Hurtado, S; Kandic, A; Kanisch, G; Karfopoulos, K L; Klemola, S; Kovar, P; Laubenstein, M; Lee, J H; Lee, J M; Lee, K B; Pierre, S; Carvalhal, G; Sima, O; Tao, Chau Van; Thanh, Tran Thien; Vidmar, T; Vukanac, I; Yang, M J

    2012-09-01

    The second part of an intercomparison of the coincidence summing correction methods is presented. This exercise concerned three volume sources, filled with liquid radioactive solution. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing corrective factors for several energies of (152)Eu and (134)Cs, and different source-to-detector distances. They are presented and discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. VLBI Digital-Backend Intercomparison Test Report

    NASA Technical Reports Server (NTRS)

    Whitney, Alan; Beaudoin, Christopher; Cappallo, Roger; Niell, Arthur; Petrachenko, Bill; Ruszczyk, Chester A.; Titus, Mike

    2013-01-01

    Issues related to digital-backend (DBE) systems can be difficult to evaluate in either local tests or actual VLBI experiments. The 2nd DBE intercomparison workshop at Haystack Observatory on 25-26 October 2012 provided a forum to explicitly address validation and interoperability issues among independent global developers of DBE equipment. This special report discusses the workshop. It identifies DBE systems that were tested at the workshop, describes the test objectives and procedures, and reports and discusses the results of the testing.

  20. The August 1988 and June 1989 radon intercomparisons at EML (Environmental Measurements Laboratory)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisenne, I.M.; George, A.C.; Keller, H.W.

    1990-06-01

    The Environmental Measurements Laboratory hosted the fifteenth and sixteenth radon intercomparison exercises in August 1988 and June 1989. Forty-five groups including US Federal facilities, USDOE Office of Health and Environmental Research contractors, national and state laboratories and foreign institutions participated in these exercises. The results show that the majority of the participants' results were within {plus minus} of the EML value at radon concentrations of 220 and 890 Bq m{sup {minus}3}. 10 refs., 4 figs., 9 tabs.

  1. Preliminary results of an intercomparison of total ozone spectrophotometers

    NASA Technical Reports Server (NTRS)

    Parsons, C. L.; Gerlach, J. C.; Williams, M. E.; Kerr, J. B.

    1981-01-01

    Preliminary results from an intercomparison of five total ozone spectrophotometers are presented. These are the Dobson spectrophotometer, the USSR M-83 ozonometer, the Canterbury filter photometer, the SenTran Company filter photometer, and the Brewer grating spectrophotometer. The pertinent characteristics of each are described, and conclusions are drawn about the agreement of each instrument's measurements with the Dobson's values over a time period of nearly one year. A discussion of the importance of calibration and long-term stability and reliability is included.

  2. Imaging Prostate Cancer Microenvironment by Collagen Hybridization

    DTIC Science & Technology

    2013-10-01

    be able to strongly chelate the In-111 in vivo over the relatively long 96 hour uptake period. Next, a p-benzyl-isothiocyanate bridged DOTA conjugate...portion of both DTPA and DOTA -chelated radioindium complex, which is also suggested by the radio TLC data. 7    Labeling with radioiodine, however

  3. Maintaining High Quality Data and Consistency Across a Diverse Flux Network: The Ameriflux QA/QC Technical Team

    NASA Astrophysics Data System (ADS)

    Chan, S.; Billesbach, D. P.; Hanson, C. V.; Biraud, S.

    2014-12-01

    The AmeriFlux quality assurance and quality control (QA/QC) technical team conducts short term (<2 weeks) intercomparisons using a portable eddy covariance system (PECS) to maintain high quality data observations and data consistency across the AmeriFlux network (http://ameriflux.lbl.gov/). Site intercomparisons identify discrepancies between the in situ and portable measurements and calculated fluxes. Findings are jointly discussed by the site staff and the QA/QC team to improve in the situ observations. Despite the relatively short duration of an individual site intercomparison, the accumulated record of all site visits (numbering over 100 since 2002) is a unique dataset. The ability to deploy redundant sensors provides a rare opportunity to identify, quantify, and understand uncertainties in eddy covariance and ancillary measurements. We present a few specific case studies from QA/QC site visits to highlight and share new and relevant findings related to eddy covariance instrumentation and operation.

  4. The ENEA criticality accident dosimetry system: a contribution to the 2002 international intercomparison at the SILENE reactor.

    PubMed

    Gualdrini, G; Bedogni, R; Fantuzzi, E; Mariotti, F

    2004-01-01

    The present paper summarises the activity carried out at the ENEA Radiation Protection Institute for updating the methodologies employed for the evaluation of the neutron and photon dose to the exposed workers in case of a criticality accident, in the framework of the 'International Intercomparison of Criticality Accident Dosimetry Systems' (Silène reactor, IRSN-CEA-Valduc June 2002). The evaluation of the neutron spectra and the neutron dosimetric quantities relies on activation detectors and on unfolding algorithms. Thermoluminescent detectors are employed for the gamma dose measurement. The work is aimed at accurately characterising the measurement system and, at the same time, testing the algorithms. Useful spectral information were included, based on Monte Carlo simulations, to take into account the potential accident scenarios of practical interest. All along this exercise intercomparison a particular attention was devoted to the 'traceability' of all the experimental and computational parameters and therefore, aimed at an easy treatment by the user.

  5. An overview of sensor calibration inter-comparison and applications

    USGS Publications Warehouse

    Xiong, Xiaoxiong; Cao, Changyong; Chander, Gyanesh

    2010-01-01

    Long-term climate data records (CDR) are often constructed using observations made by multiple Earth observing sensors over a broad range of spectra and a large scale in both time and space. These sensors can be of the same or different types operated on the same or different platforms. They can be developed and built with different technologies and are likely operated over different time spans. It has been known that the uncertainty of climate models and data records depends not only on the calibration quality (accuracy and stability) of individual sensors, but also on their calibration consistency across instruments and platforms. Therefore, sensor calibration inter-comparison and validation have become increasingly demanding and will continue to play an important role for a better understanding of the science product quality. This paper provides an overview of different methodologies, which have been successfully applied for sensor calibration inter-comparison. Specific examples using different sensors, including MODIS, AVHRR, and ETM+, are presented to illustrate the implementation of these methodologies.

  6. BIPM project: Intercomparison of water triple-point cells

    NASA Astrophysics Data System (ADS)

    Chattle, M. V.; Butler, J.

    1994-12-01

    The paper presents the results of an intercomparison between 3 triple point of water cells circulated by the Bureau International des Poids et Measures (BIPM), and a cell which is one of those used as a reference cell at the National Physical Laboratory (NPL). All 4 cells were prepared, stored and measured in the manner normally adopted at NPL. The results of the intercomparison show that over the course of about 6 weeks the temperatures of the 3 circulated cells generally agreed within 0.20 mK, with a maximum difference of 0.27(7) mK. Over the same period, the total variations of temperature measured in the 3 individual cells were 0.04 mK, 0.08 mK and 0.18 mK, respectively; the NPL cell varied by 0.10 mK. Gallium point measurements made over a similar period confirmed that these differences were partly due to small drifts in the thermometer resistance or in the measuring system.

  7. FACE-IT. A Science Gateway for Food Security Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montella, Raffaele; Kelly, David; Xiong, Wei

    Progress in sustainability science is hindered by challenges in creating and managing complex data acquisition, processing, simulation, post-processing, and intercomparison pipelines. To address these challenges, we developed the Framework to Advance Climate, Economic, and Impact Investigations with Information Technology (FACE-IT) for crop and climate impact assessments. This integrated data processing and simulation framework enables data ingest from geospatial archives; data regridding, aggregation, and other processing prior to simulation; large-scale climate impact simulations with agricultural and other models, leveraging high-performance and cloud computing; and post-processing to produce aggregated yields and ensemble variables needed for statistics, for model intercomparison, and to connectmore » biophysical models to global and regional economic models. FACE-IT leverages the capabilities of the Globus Galaxies platform to enable the capture of workflows and outputs in well-defined, reusable, and comparable forms. We describe FACE-IT and applications within the Agricultural Model Intercomparison and Improvement Project and the Center for Robust Decision-making on Climate and Energy Policy.« less

  8. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vives i Batlle, J.; Beresford, N. A.; Beaugelin-Seiller, K.

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of 90Sr, 131I and 137Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and whichmore » uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters.« less

  9. The Second Cabauw Intercomparison of Nitrogen Dioxide Measuring Instruments (CINDI-2)

    NASA Astrophysics Data System (ADS)

    Van Roozendael, M.; Hendrick, F.; Apituley, A.; Kreher, K.; Friess, U.; Richter, A.; Wagner, T.; Fehr, T.

    2017-12-01

    For the validation of space borne UV-Vis observations of air quality gases, ground based remote-sensing instruments using the MAXDOAS technique are an excellent choice, since they rely on similar retrieval techniques as the observations from orbit. Over the last decade, MAXDOAS instruments of various designs (including PANDORA systems) have been deployed worldwide forming the basis for a global ground based reference network suitable for the validation of future satellite sensors, such as TROPOMI/Sentinel-5 precursor, GEMS, TEMPO, and Sentinel 4 and 5. To ensure proper traceability of these observations, assess their accuracy and progress towards harmonized data acquisition and delivery, a thorough intercomparison campaign known as the Second Cabauw Intercomparison of Nitrogen Dioxide Measuring Instruments (CINDI-2) was held in Cabauw, The Netherlands during the month of September 2016. About 35 MAXDOAS instruments operated by 25 different groups were deployed, together with systems providing key ancillary in-situ measurements of NO2 and aerosol optical properties, as well as vertical profiles of NO2 by lidar and sonde and vertical profiles of aerosol optical properties by Raman lidar. We provide an overview of the main outcome of the campaign, which included a formal semi-blind slant column intercomparison and a number of additional exercises aiming at assessing the potential of the MAXDOAS technique for retrieving vertically-resolved information on NO2, aerosol, HCHO, O3 and a few other more challenging species such as HONO and glyoxal.

  10. The 1996 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers

    PubMed Central

    Early, Edward; Thompson, Ambler; Johnson, Carol; DeLuisi, John; Disterhoft, Patrick; Wardle, David; Wu, Edmund; Mou, Wanfeng; Ehramjian, James; Tusson, John; Mestechkina, Tanya; Beaubian, Mark; Gibson, James; Hayes, Douglass

    1998-01-01

    Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, the third North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers was held June 17–25, 1996 at Table Mountain outside Boulder, Colorado, USA. This Intercomparison was coordinated by the National Institute of Standards and Technology (NIST) and the National Oceanic and Atmospheric Administration (NOAA). Participating agencies were the Environmental Protection Agency; the National Science Foundation; the Smithsonian Environmental Research Center; the Department of Agriculture; and the Atmospheric Environment Service, Canada. The spectral irradiances of participants’ calibrated standard lamps were measured at NIST prior to the Intercomparison. The spectral irradiance scales used by the participants agreed with the NIST scale within the combined uncertainties, and for all lamps the spectral irradiance in the horizontal position was lower than that in the vertical position. Instruments were characterized for wavelength uncertainty, bandwidth, stray-light rejection, and spectral irradiance responsivity, the latter with NIST standard lamps operating in specially designed field calibration units. The spectral irradiance responsivity demonstrated instabilities for some instruments. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST standard lamps, the measured solar irradiances had some unexplained systematic differences between instruments. PMID:28009358

  11. Climate and Energy-Water-Land System Interactions Technical Report to the U.S. Department of Energy in Support of the National Climate Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skaggs, Richard; Hibbard, Kathleen A.; Frumhoff, Peter

    2012-03-01

    This report provides a framework to characterize and understand the important elements of climate and energy-water-land (EWL) system interactions. It identifies many of the important issues, discusses our understanding of those issues, and presents a long-term research program research needs to address the priority scientific challenges and gaps in our understanding. Much of the discussion is organized around two discrete case studies with the broad themes of (1) extreme events and (2) regional intercomparisons. These case studies help demonstrate unique ways in which energy-water-land interactions can occur and be influenced by climate.

  12. Intercomparison of SOUP, ASP, LPSP, and MDI magnetograms

    NASA Astrophysics Data System (ADS)

    Berger, T.; Lites, B.; Martinez-Pillet, V.; Tarbell, T.; Title, A.

    2001-05-01

    We compare simultaneous magnetograms of a solar active region taken by the Advanced Stokes Polarimeter (ASP) and the Solar Optical Universal Polimeter (SOUP) in 1998. In addition we compare magnetograms taken by the La Palma Stokes Polarimeter (LPSP), the Michelson Doppler Imager (MDI) on SOHO, and the SOUP instrument in 2000. The SOUP instrument on the Swedish Vacuum Solar Telescope (SVST) attains the highest spatial resolution but has the least understood calibration; the ASP on the Dunn Solar Telescope (DST) at Sacramento Peak attains the highest magnetic field precision. The goal of the program is to better quantify the SOUP magnetograms and thereby study magnetic element dynamics in the photosphere with higher precision.

  13. Design of the MISMIP+, ISOMIP+, and MISOMIP ice-sheet, ocean, and coupled ice sheet-ocean intercomparison projects

    NASA Astrophysics Data System (ADS)

    Asay-Davis, Xylar; Cornford, Stephen; Martin, Daniel; Gudmundsson, Hilmar; Holland, David; Holland, Denise

    2015-04-01

    The MISMIP and MISMIP3D marine ice sheet model intercomparison exercises have become popular benchmarks, and several modeling groups have used them to show how their models compare to both analytical results and other models. Similarly, the ISOMIP (Ice Shelf-Ocean Model Intercomparison Project) experiments have acted as a proving ground for ocean models with sub-ice-shelf cavities.As coupled ice sheet-ocean models become available, an updated set of benchmark experiments is needed. To this end, we propose sequel experiments, MISMIP+ and ISOMIP+, with an end goal of coupling the two in a third intercomparison exercise, MISOMIP (the Marine Ice Sheet-Ocean Model Intercomparison Project). Like MISMIP3D, the MISMIP+ experiments take place in an idealized, three-dimensional setting and compare full 3D (Stokes) and reduced, hydrostatic models. Unlike the earlier exercises, the primary focus will be the response of models to sub-shelf melting. The chosen configuration features an ice shelf that experiences substantial lateral shear and buttresses the upstream ice, and so is well suited to melting experiments. Differences between the steady states of each model are minor compared to the response to melt-rate perturbations, reflecting typical real-world applications where parameters are chosen so that the initial states of all models tend to match observations. The three ISOMIP+ experiments have been designed to to make use of the same bedrock topography as MISMIP+ and using ice-shelf geometries from MISMIP+ results produced by the BISICLES ice-sheet model. The first two experiments use static ice-shelf geometries to simulate the evolution of ocean dynamics and resulting melt rates to a quasi-steady state when far-field forcing changes in either from cold to warm or from warm to cold states. The third experiment prescribes 200 years of dynamic ice-shelf geometry (with both retreating and advancing ice) based on a BISICLES simulation along with similar flips between warm and cold states in the far-field ocean forcing. The MISOMIP experiment combines the MISMIP+ experiments with the third ISOMIP+ experiment. Changes in far-field ocean forcing lead to a rapid (over ~1-2 years) increase in sub-ice-shelf melting, which is allowed to drive ice-shelf retreat for ~100 years. Then, the far-field forcing is switched to a cold state, leading to a rapid decrease in melting and a subsequent advance over ~100 years. To illustrate, we present results from BISICLES and POP2x experiments for each of the three intercomparison exercises.

  14. Intercomparison of Operational Ocean Forecasting Systems in the framework of GODAE

    NASA Astrophysics Data System (ADS)

    Hernandez, F.

    2009-04-01

    One of the main benefits of the GODAE 10-year activity is the implementation of ocean forecasting systems in several countries. In 2008, several systems are operated routinely, at global or basin scale. Among them, the BLUElink (Australia), HYCOM (USA), MOVE/MRI.COM (Japan), Mercator (France), FOAM (United Kingdom), TOPAZ (Norway) and C-NOOFS (Canada) systems offered to demonstrate their operational feasibility by performing an intercomparison exercise during a three months period (February to April 2008). The objectives were: a) to show that operational ocean forecasting systems are operated routinely in different countries, and that they can interact; b) to perform in a similar way a scientific validation aimed to assess the quality of the ocean estimates, the performance, and forecasting capabilities of each system; and c) to learn from this intercomparison exercise to increase inter-operability and collaboration in real time. The intercomparison relies on the assessment strategy developed for the EU MERSEA project, where diagnostics over the global ocean have been revisited by the GODAE contributors. This approach, based on metrics, allow for each system: a) to verify if ocean estimates are consistent with the current general knowledge of the dynamics; and b) to evaluate the accuracy of delivered products, compared to space and in-situ observations. Using the same diagnostics also allows one to intercompare the results from each system consistently. Water masses and general circulation description by the different systems are consistent with WOA05 Levitus climatology. The large scale dynamics (tropical, subtropical and subpolar gyres ) are also correctly reproduced. At short scales, benefit of high resolution systems can be evidenced on the turbulent eddy field, in particular when compared to eddy kinetic energy deduced from satellite altimetry of drifter observations. Comparisons to high resolution SST products show some discrepancies on ocean surface representation, either due to model and forcing fields errors, or assimilation scheme efficiency. Comparisons to sea-ice satellite products also evidence discrepancies linked to model, forcing and assimilation strategies of each forecasting system. Key words: Intercomparison, ocean analysis, operational oceanography, system assessment, metrics, validation GODAE Intercomparison Team: L. Bertino (NERSC/Norway), G. Brassington (BMRC/Australia), E. Chassignet (FSU/USA), J. Cummings (NRL/USA), F. Davidson (DFO/Canda), M. Drévillon (CERFACS/France), P. Hacker (IPRC/USA), M. Kamachi (MRI/Japan), J.-M. Lellouche (CERFACS/France), K. A. Lisæter (NERSC/Norway), R. Mahdon (UKMO/UK), M. Martin (UKMO/UK), A. Ratsimandresy (DFO/Canada), and C. Regnier (Mercator Ocean/France)

  15. Harold Knapp and the geography of normal controversy: radioiodine in the historical environment.

    PubMed

    Kirsch, Scott

    2004-01-01

    In 1962, after high levels of the isotope Iodine-131 were detected in Utah milk supplies, Dr. Harold Knapp, a mathematician working for the AEC's Division of Biology and Medicine, developed a new model of estimating, first, the relation between a single deposition of radioactive fallout on pasturage and the levels of Iodine-131 in fresh milk and, second, the total dose to human thyroids, resulting from daily intake of the contaminated milk. The implications of Knapp's findings were enormous. They suggested that short-living radioiodine, rather than long-living nuclides such as radiostrontium, posed the greatest hazard from nuclear test fallout and that children raised in Nevada and Utah during the 1950s had been exposed to internal radiation doses far in excess of recommended guidelines. This paper explores the explicit historical revisionism of Knapp's study, his refusal, contra normal AEC practices of knowledge production and spatial representation, to distance himself from the people and places downwind from the Nevada Test Site, and the reactions his work provoked among his AEC colleagues.

  16. Guidelines for the treatment of childhood-onset Graves' disease in Japan, 2016.

    PubMed

    Minamitani, Kanshi; Sato, Hirokazu; Ohye, Hidemi; Harada, Shohei; Arisaka, Osamu

    2017-01-01

    Purpose behind developing these guidelines: Over one decade ago, the "Guidelines for the Treatment of Graves' Disease with Antithyroid Drug, 2006" (Japan Thyroid Association (JTA)) were published as the standard drug therapy protocol for Graves' disease. The "Guidelines for the Treatment of Childhood-Onset Graves' Disease with Antithyroid Drug in Japan, 2008" were published to provide guidance on the treatment of pediatric patients. Based on new evidence, a revised version of the "Guidelines for the Treatment of Graves' Disease with Antithyroid Drug, 2006" (JTA) was published in 2011, combined with the "Handbook of Radioiodine Therapy for Graves' Disease 2007" (JTA). Subsequently, newer findings on pediatric Graves' disease have been reported. Propylthiouracil (PTU)-induced serious hepatopathy is an important problem in pediatric patients. The American Thyroid Association's guidelines suggest that, in principle, physicians must not administer PTU to children. On the other hand, the "Guidelines for the Treatment of Graves' Disease with Antithyroid Drug, 2011" (JTA) state that radioiodine therapy is no longer considered a "fundamental contraindication" in children. Therefore, the "Guidelines for the Treatment of Childhood-Onset Graves' Disease with Antithyroid Drug in Japan, 2008" required revision.

  17. Silver-functionalized silica aerogels and their application in the removal of iodine from aqueous environments

    DOE PAGES

    Asmussen, R. Matthew; Matyas, Josef; Qafoku, Nikolla P.; ...

    2018-05-01

    Here, one of the key challenges for radioactive waste management is the efficient capture and immobilization of radioiodine, because of its radiotoxicity, high mobility in the environment, and long half-life (t 1/2 = 1.57 × 10 7 years). Silver-functionalized silica aerogel (AgAero) represents a strong candidate for safe sequestration of radioiodine from various nuclear waste streams and subsurface environments. Batch sorption experiments up to 10 days long were carried out in oxic and anoxic conditions in both deionized water (DIW) and various Hanford Site Waste Treatment Plant (WTP) off-gas condensate simulants containing from 5 to 10 ppm of iodide (Imore » –) or iodate (IO 3 –). Also tested was the selectivity of AgAero towards I – in the presence of other halide anions. AgAero exhibited fast and complete removal of I – from DIW, slower but complete removal of I – from WTP off-gas simulants, preferred removal of I – over Br – and Cl –, and it demonstrated ability to remove IO 3 – through reduction to I –.« less

  18. Effect of the route of administration on the biodistribution of radioiodinated OV-TL 3 F(ab')2 in experimental ovarian cancer.

    PubMed

    Tibben, J G; Massuger, L F; Boerman, O C; Borm, G F; Claessens, R A; Corstens, F H

    1994-11-01

    The effect of the route administration on the distribution of radioiodinated OV-TL 3 F(ab')2 was studied in Balb/c female mice with intraperitoneal or subcutaneous ovarian carcinoma xenografts. In the intraperitoneal tumour model in which both ascites and solid tumour deposits were present, intraperitoneal administration resulted in a lower estimated radiation dose to blood as compared with intravenous administration. In this model normalization to equal estimated radiation doses to blood for both routes of administration indicated that a twice as high estimated radiation dose can be guided to solid intraperitoneal tumour deposits following intraperitoneal administration. Evacuation of ascitic tumour cells prior to monoclonal antibody injection further increased the estimated radiation dose to solid intraperitoneal tumour deposits following intraperitoneal delivery. Following simultaneous intravenous and intraperitoneal injection of the monoclonal antibody, tissue uptake showed no relevant differences in the subcutaneous tumour model. Overall, the intraperitoneal route of administration was found to be the best choice for therapeutic delivery of iodine-131 labelled monoclonal antibodies.

  19. Silver-functionalized silica aerogels and their application in the removal of iodine from aqueous environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asmussen, R. Matthew; Matyas, Josef; Qafoku, Nikolla P.

    Here, one of the key challenges for radioactive waste management is the efficient capture and immobilization of radioiodine, because of its radiotoxicity, high mobility in the environment, and long half-life (t 1/2 = 1.57 × 10 7 years). Silver-functionalized silica aerogel (AgAero) represents a strong candidate for safe sequestration of radioiodine from various nuclear waste streams and subsurface environments. Batch sorption experiments up to 10 days long were carried out in oxic and anoxic conditions in both deionized water (DIW) and various Hanford Site Waste Treatment Plant (WTP) off-gas condensate simulants containing from 5 to 10 ppm of iodide (Imore » –) or iodate (IO 3 –). Also tested was the selectivity of AgAero towards I – in the presence of other halide anions. AgAero exhibited fast and complete removal of I – from DIW, slower but complete removal of I – from WTP off-gas simulants, preferred removal of I – over Br – and Cl –, and it demonstrated ability to remove IO 3 – through reduction to I –.« less

  20. [Treatment of hyperthyroidism with radioiodine during hemodialysis: Report of one case].

    PubMed

    Hurtado, Claudia; Báez, María Soledad; Bate, Anabel; Opazo, Claudio; Troncoso, Mauricio

    2017-05-01

    Although radioiodine (131-I) can be used as treatment of hyperthyroidism for patients in hemodialysis, its use is limited and the experience is mainly related to differentiated thyroid carcinoma. We report a 58 years old female on hemodialysis with recurrent hyperthyroidism after propylthiouracil treatment. She was successfully treated with 131-I and four months after the intervention her euthyroid state was confirmed. We measured 131-I activity in blood, dialysate liquid and other waste products, as well as patient radiation exposure rates. We found that 131-I elimination was prolonged through time with no major dependence on hemodialysis, as opposed to the elimination of 131-I in patients with thyroid carcinoma. This was probably due to high radiotracer uptake in hyper functioning thyroid tissue. Conversely, radiation content in dialysate wastes or equipment was minimal. Furthermore, the rate of both environmental exposure and exposure of nursing staff in charge of hemodialysis sessions, was minimal and met international security standards. In conclusion, I-131 therapy showed both appropriate effectiveness and safety in this case and may be considered as a suitable treatment alternative to thyroidectomy when antithyroid drugs are unsuccessful.

  1. Silver-functionalized silica aerogels and their application in the removal of iodine from aqueous environments.

    PubMed

    Asmussen, R Matthew; Matyáš, Josef; Qafoku, Nikolla P; Kruger, Albert A

    2018-05-01

    One of the key challenges for radioactive waste management is the efficient capture and immobilization of radioiodine, because of its radiotoxicity, high mobility in the environment, and long half-life (t 1/2  = 1.57 × 10 7 years). Silver-functionalized silica aerogel (AgAero) represents a strong candidate for safe sequestration of radioiodine from various nuclear waste streams and subsurface environments. Batch sorption experiments up to 10 days long were carried out in oxic and anoxic conditions in both deionized water (DIW) and various Hanford Site Waste Treatment Plant (WTP) off-gas condensate simulants containing from 5 to 10 ppm of iodide (I - ) or iodate (IO 3 - ). Also tested was the selectivity of AgAero towards I - in the presence of other halide anions. AgAero exhibited fast and complete removal of I - from DIW, slower but complete removal of I - from WTP off-gas simulants, preferred removal of I - over Br - and Cl - , and it demonstrated ability to remove IO 3 - through reduction to I - . Copyright © 2018 Elsevier B.V. All rights reserved.

  2. GEOS observation systems intercomparison investigation results

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1974-01-01

    The results of an investigation designed to determine the relative accuracy and precision of the different types of geodetic observation systems used by NASA is presented. A collocation technique was used to minimize the effects of uncertainties in the relative station locations and in the earth's gravity field model by installing accurate reference tracking systems close to the systems to be compared, and by precisely determining their relative survey. The Goddard laser and camera systems were shipped to selected sites, where they tracked the GEOS satellite simultaneously with other systems for an intercomparison observation.

  3. Intercomparison of techniques for the non-invasive measurement of bone mass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cohn, S.H.

    1981-01-01

    A variety of methods are presently available for the non-invasive measurement of bone mass of both normal individuals and patients with metabolic disorders. Chief among these methods are radiographic techniques such as radiogrammetry, photon absorptiometry, computer tomography, Compton scattering and neutron activation analysis. In this review, the salient features of the bone measurement techniques are discussed along with their accuracy and precision. The advantages and disadvantages of the various techniques for measuring bone mass are summarized. Where possible, intercomparisons are made of the various techniques.

  4. Intercomparison of photon dose measurements at the 8 MeV electron accelerator

    NASA Astrophysics Data System (ADS)

    Angelescu, T.; Ghiordănescu, N.; Băl ţă ţeanu, N.; Labău, V.; Vasilescu, A.

    1997-02-01

    Measurements of dose with thermoluminescent detectors (TLD) and an ionisation chamber were performed in the range of 5-70 Gy in the electron bremsstrahlung field with a maximum energy of 8 MeV of the Bucharest linear accelerator. Previous calibration was done with a 60Co source. The results of the intercomparison were used in dosimetry of the n - γ field of the ΣΣ irradiation facility, with a photon spectrum similar to the 8 MeV bremsstrahlung field [T. Angelescu et al., Nucl. Instr. and Meth. A 378 (1996) 594].

  5. Visible light nitrogen dioxide spectrophotometer intercomparison: Mount Kobau, British Columbia, July 28 to August 10, 1991

    NASA Technical Reports Server (NTRS)

    Mcelroy, C. T.; Elokhov, A. S.; Elansky, N.; Frank, H.; Johnston, P.; Kerr, J. B.

    1994-01-01

    Under the auspices of the World Meteorological Organization, Environment Canada hosted an international comparison of visible light spectrophotometers at Mt. Kobau, British Columbia in August of 1991. Instruments from four countries were involved. The intercomparison results have indicated that some significant differences exist in the responses of the various instruments, and have provided a basis for the comparison of the historical data sets which currently exist as a result of the independent researches carried out in the past in the former Soviet Union, New Zealand, and Canada.

  6. Preablation 131-I scans with SPECT/CT contribute to thyroid cancer risk stratification and 131-I therapy planning.

    PubMed

    Avram, Anca M; Esfandiari, Nazanene H; Wong, Ka Kit

    2015-05-01

    The use of preablation diagnostic radioiodine scans for risk stratification and radioiodine therapy planning for differentiated thyroid cancer (DTC) remains controversial. The objective was to assess the contribution of preablation diagnostic 131-I scans with SPECT/CT (Dx 131-I scan) to (1) the risk stratification and (2) the postoperative management of DTC. The study was designed as a prospective sequential patient series. The study was conducted at a University hospital. Three hundred twenty patients (pts) with DTC (219F; 101M, mean age 47.3 ± 16.4 y, range 10-90) were studied. Using clinical and histopathology information an endocrinologist performed risk stratification and determined postoperative management with respect to radioiodine therapy (RAI) planning. The decision to withhold or to administer RAI, and the recommended low, medium or high therapeutic 131-I activity were recorded. Dx 131-I scans were performed and interpreted by two nuclear medicine physicians as showing thyroid remnant, cervical nodal, or distant metastases. The endocrinologist then reperformed risk stratification and reformulated management after consideration of Dx 131-I scans and stimulated thyroglobulin (Tg) information. Main outcome measures were changes in risk stratification and management after Dx 131-I scans. Detection of unsuspected nodal and distant metastases and elevated stimulated Tg levels resulted in a change in the estimated risk of recurrence in 15% of patients, and management in 31% of patients, as compared to initial risk stratification and management based on histopathology alone. Both imaging data and stimulated thyroglobulin levels acquired at the time of Dx 131-I scans are consequential for 131-I therapy planning, providing information that changes risk stratification in 15% of patients as compared to recurrence risk estimation based on histopathology alone. Dx 131-I scans contribute to risk stratification by defining residual nodal and distant metastatic disease, changing clinical management in 29.4% of patients.

  7. Alterations of Global DNA Methylation and DNA Methyltransferase Expression in T and B Lymphocytes from Patients with Newly Diagnosed Autoimmune Thyroid Diseases After Treatment: A Follow-Up Study.

    PubMed

    Guo, Qingling; Wu, Dan; Yu, Huixin; Bao, Jiandong; Peng, Shiqiao; Shan, Zhongyan; Guan, Haixia; Teng, Weiping

    2018-03-01

    Dysregulated DNA methylation in lymphocytes has been linked to autoimmune disorders. The aims of this study were to identify global DNA methylation patterns in patients with autoimmune thyroid diseases and to observe methylation changes after treatment for these conditions. A cross-sectional study was conducted, including the following patients: 51 with newly diagnosed Graves' disease (GD), 28 with autoimmune hypothyroidism (AIT), 29 with positive thyroid autoantibodies, and 39 matched healthy volunteers. Forty GD patients treated with radioiodine or antithyroid drugs and 28 AIT patients treated with L-thyroxine were followed for three months. Serum free triiodothyronine, free thyroxine, thyrotropin, thyroid peroxidase antibodies, thyroglobulin antibodies, and thyrotropin receptor antibodies were assayed using electrochemiluminescent immunoassays. CD3 + T and CD19 + B cells were separated by flow cytometry for total DNA and RNA extraction. Global DNA methylation levels were determined by absorptiometry using a methylation quantification kit. DNA methyltransferase (DNMT) expression levels were detected by real-time polymerase chain reaction. Hypomethylation and down-regulated DNMT1 expression in T and B lymphocytes were observed in the newly diagnosed GD patients. Neither the AIT patients nor the positive thyroid autoantibodies patients exhibited differences in their global DNA methylation status or DNMT mRNA levels compared with healthy controls. Antithyroid drugs restored global methylation and DNMT1 expression in both T and B lymphocytes, whereas radioiodine therapy affected only T cells. L-thyroxine replacement did not alter the methylation or DNMT expression levels in lymphocytes. The global methylation levels of B cells were negatively correlated with the serum thyroid peroxidase antibodies in patients with autoimmune thyroid diseases. Hyperthyroid patients with newly diagnosed GD had global hypomethylation and lower DNMT1 expression in T and B lymphocytes. The results provide the first demonstration that antithyroid drugs or radioiodine treatment restore global DNA methylation and DNMT1 expression with concurrent relief of hyperthyroidism.

  8. Chinese herbal medicines for hyperthyroidism.

    PubMed

    Zen, X X; Yuan, Y; Liu, Y; Wu, T X; Han, S

    2007-04-18

    Hyperthyroidism is a disease in which excessive amounts of thyroid hormones circulate in the blood. Patients, among other things suffer from tachycardia, warm moist skin and raised body temperature. The treatment of hyperthyroidism includes symptom relief and therapy with antithyroid medications, radioiodine and thyroidectomy. Medicinal herbs are used alone or in combination with antithyroid agents to treat hyperthyroidism in China and some other countries. To assess the effects of Chinese herbal medicines for treating hyperthyroidism. Studies were obtained from computerised searches of MEDLINE, EMBASE, The Cochrane Library, the Chinese Biomedical Database. Randomised controlled trials comparing the effects of Chinese herbal medicines alone with Chinese herbal medicines combined with antithyroid drugs, radioiodine or both. Three authors interviewed authors of all potentially relevant studies by telephone to verify randomisation procedures. One author entered data into a data extraction form and another author verified the results of this procedure. Thirteen relevant trials with 1770 participants were included. All of them were of low quality. Fifty-two studies still need to be assessed because the original authors could not be interviewed. None of these trials analysed mortality, health related quality of life, economic outcomes or compliance. Compared to antithyroid drugs alone the results showed that Chinese herbal medicines combined with antithyroid drugs may offer benefits in lowering relapse rates, reducing the incidence of adverse effects, relieving symptoms, improving thyroid antibody status and thyroid function. Two trials investigated Chinese herbal medicine versus radioiodine and reported improvements in anxiety, tachycardia and heat intolerance. However, thyroid function - with the exception of restored thyroid stimulating hormone (TSH) - was not significantly altered. The results suggest that traditional Chinese herbal medicines added to other routine treatment have a therapeutic potential for people with hyperthyroidism. However, due to methodological limitations, we could not identify a well-designed trial to provide strong evidence for Chinese traditional herbal medicine in the treatment of hyperthyroidism. Thus, we currently cannot recommend any single preparation or formulation for clinical use.

  9. COMBINATION OF MOLECULAR ADSORBENT RECIRCULATING SYSTEM AND RADIOIODINE FOR THE TREATMENT OF CONCURRENT HYPERTHYROIDISM AND SEVERE LIVER DYSFUNCTION: A RETROSPECTIVE COHORT STUDY.

    PubMed

    Zhang, Qing; Guan, Yanxing; Xiang, Tianxin; Liu, Shaozheng; Chen, Qingjie; Zhang, Qing

    2017-02-01

    The treatment of hyperthyroidism associated with severe liver dysfunction (LD) is a clinical challenge, and there has been no unified examination of this problem. The objective of this study was to assess the efficacy and safety of radioiodine ( 131 I) in combination with a molecular adsorbent recirculating system (MARS) for the treatment of hyperthyroidism complicated by severe liver LD. A total of 116 hyperthyroidism patients with concomitant LD who received MARS treatment were studied retrospectively. The patients were grouped according to whether or not they also received 131 I treatment: Group 1 (59 patients) received 131 I following MARS treatment, while Group 2 (57 cases) received only MARS. Clinical outcomes, including thyroid hormone levels, liver function parameters, and therapeutic efficacy were calculated. The overall response rate was significantly greater in Group 1 than in Group 2 (P<.01). The clinical indicators improved significantly in both groups 3 months after treatment compared with before treatment (P<.05), but Group 1 showed a greater improvement. Compared with Group 1, patients in Group 2 had a longer stay in hospital (P<.05), and received more frequent MARS treatments (P<.05). The combination of MARS and 131 I for the treatment of hyperthyroidism complicated by severe LD was effective and safe. The use of this system could rapidly improve liver function and metabolism, allowing 131 I therapy to be applied as early as possible with a shortened recovery time of liver function. ALSS = artificial liver support system ALT = alanine transaminase AST = aspartate transaminase ATD = antithyroid drugs DBil = direct bilirubin FT3 = free tri-iodothyronine FT4 = free thyroxine 131 I = radioiodine INR = international normalized ratio LD = liver dysfunction MARS = molecular adsorbent recirculating system MELD = model for end-stage liver disease PT = prothrombin time TBil = total bilirubin TSH = thyroid-stimulating hormone.

  10. Hierarchy of treatment variables affecting outcome of 131I therapy in thyroid cancer patients with lung metastases.

    PubMed

    Kozak, Oksana V; Sukach, Georgiy G; Korchinskaya, Oksana I; Trembach, Alexander M; Turicina, Viktoria L; Voit, Natalia U

    2005-06-01

    To assess the correlations between the first 131I activity value, time interval between the courses of radioiodine treatment and the overall number of courses required for total destruction of lung metastases in patients with differentiated thyroid cancer with metastatic lesions in lungs. 27 patients with differentiated thyroid cancer with metastases in lungs have been treated with radioiodine after surgical intervention. Activities administered amounted from 1600 to 7980 MBq. The number of radioiodine courses before total ablation of all metastatic lesions amounted from 1 to 10. Time interval between the 1st and the 2nd courses amounted from 3.5 to 11.5 months (6 months in average). The regression analysis of the data has been made. The exponential model fits the actual number of courses as a function of the first-second activity value and time interval between the courses. The first activity has a decisive influence on the number of courses required for total metastases ablation. The greater was the first activity value, the lesser was the overall number of courses. Increasing time interval between 1st and 2nd courses to 10 months seems to result in reducing the number of courses. Nevertheless even in the case of high activities the probability to undergone less then 3 courses is low. According to the proposed model in thyroid cancer patients with metastases in lungs the first activity should be not lesser than 6000 MBq, time interval between treatments--approximately 10 months. The results of our study suggest that individual factors such as histology, the number and the size of metastases in lymph nodes could not contribute more to the final outcome than the treatment variables, namely the first-second activity and time interval, nor could they affect the hierarchy of the effects revealed for the treatment variables.

  11. Intercomparison and validation of continental water level products derived from satellite radar altimetry

    NASA Astrophysics Data System (ADS)

    Ričko, Martina; Birkett, Charon M.; Carton, James A.; Crétaux, Jean-François

    2012-01-01

    Satellite radar altimeter measurements of lake and reservoir water levels complement in situ observations by providing stage information for ungauged basins and by filling data gaps in existing gauge records. Such additional measurements assist both research and operational programs. However, for a particular lake or reservoir, altimetric products offered to end-users may differ due to choice of employed instrument, processing technique, and applied geophysical corrections. To explore these differences, particularly with their potential impact on climate-based research, an intercomparison of three web-based water-level products (produced by Laboratoire d'Etudes en Géophysique et Océanographie Spatiale, National Aeronautics and Space Administration/United States Department of Agriculture, and European Space Agency/De Montfort University) has been undertaken based on 18 lakes and reservoirs. The products are well correlated with each other (r=0.87 to 0.99) and where in situ data are available are quite well correlated with the gauge measurements (r=0.73 to 0.99). Despite variations in data processing, the poorest root-mean-square differences between any altimeter product and gauge data (˜0.20 to 1.41 m) occur for the narrow reservoirs and smaller lakes. The largest discrepancies between the altimeter products occur for the lakes that freeze (Lake Athabasca and Woods). The current altimeter products provide acceptable accuracy, long-term trends and seasonality for climate applications. We discuss the merits of each product system, but recommend further validations and the provision of ice-detection flags.

  12. The Global Precipitation Climatology Project: First Algorithm Intercomparison Project

    NASA Technical Reports Server (NTRS)

    Arkin, Phillip A.; Xie, Pingping

    1994-01-01

    The Global Precipitation Climatology Project (GPCP) was established by the World Climate Research Program to produce global analyses of the area- and time-averaged precipitation for use in climate research. To achieve the required spatial coverage, the GPCP uses simple rainfall estimates derived from IR and microwave satellite observations. In this paper, we describe the GPCP and its first Algorithm Intercomparison Project (AIP/1), which compared a variety of rainfall estimates derived from Geostationary Meteorological Satellite visible and IR observations and Special Sensor Microwave/Imager (SSM/I) microwave observations with rainfall derived from a combination of radar and raingage data over the Japanese islands and the adjacent ocean regions during the June and mid-July through mid-August periods of 1989. To investigate potential improvements in the use of satellite IR data for the estimation of large-scale rainfall for the GPCP, the relationship between rainfall and the fractional coverage of cold clouds in the AIP/1 dataset is examined. Linear regressions between fractional coverage and rainfall are analyzed for a number of latitude-longitude areas and for a range of averaging times. The results show distinct differences in the character of the relationship for different portions of the area. These results suggest that the simple IR-based estimation technique currently used in the GPCP can be used to estimate rainfall for global tropical and subtropical areas, provided that a method for adjusting the proportional coefficient for varying areas and seasons can be determined.

  13. Inter-comparison of time series models of lake levels predicted by several modeling strategies

    NASA Astrophysics Data System (ADS)

    Khatibi, R.; Ghorbani, M. A.; Naghipour, L.; Jothiprakash, V.; Fathima, T. A.; Fazelifard, M. H.

    2014-04-01

    Five modeling strategies are employed to analyze water level time series of six lakes with different physical characteristics such as shape, size, altitude and range of variations. The models comprise chaos theory, Auto-Regressive Integrated Moving Average (ARIMA) - treated for seasonality and hence SARIMA, Artificial Neural Networks (ANN), Gene Expression Programming (GEP) and Multiple Linear Regression (MLR). Each is formulated on a different premise with different underlying assumptions. Chaos theory is elaborated in a greater detail as it is customary to identify the existence of chaotic signals by a number of techniques (e.g. average mutual information and false nearest neighbors) and future values are predicted using the Nonlinear Local Prediction (NLP) technique. This paper takes a critical view of past inter-comparison studies seeking a superior performance, against which it is reported that (i) the performances of all five modeling strategies vary from good to poor, hampering the recommendation of a clear-cut predictive model; (ii) the performances of the datasets of two cases are consistently better with all five modeling strategies; (iii) in other cases, their performances are poor but the results can still be fit-for-purpose; (iv) the simultaneous good performances of NLP and SARIMA pull their underlying assumptions to different ends, which cannot be reconciled. A number of arguments are presented including the culture of pluralism, according to which the various modeling strategies facilitate an insight into the data from different vantages.

  14. United States Transuranium and Uranium Registries. Annual Report, October 1, 1993--September 30, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kathren, R.L.; Harwick, L.A.

    1995-08-01

    This report summarizes the salient activities and progress of the United States Transuranium. and Uranium Registries for the period October 1, 1993 through September 30, 1994, along with details of specific programs areas including the National Human Radiobiology Tissue Repository (NHRTR) and tissue radiochemistry analysis project. Responsibility for tissue radioanalysis was transferred from Los Alamos National Laboratory to Washington State University in February 1994. The University of Washington was selected as the Quality Assurance/Quality Control laboratory and a three way intercomparison with them and LANL has been initiated. The results of the initial alpha spectrometry intercomparison showed excellent agreement amongmore » the laboratories and are documented in full in the Appendices to the report. The NHRTR serves as the initial point of receipt for samples received from participants in the USTUR program. Samples are weighed, divided, and reweighed, and a portion retained by the NHRTR as backup or for use in other studies. Tissue specimens retained in the NHRTR are maintained frozen at -70 C and include not only those from USTUR registrants but also those from the radium dial painter and thorium worker studies formerly conducted by Argonne National Laboratory. In addition, there are fixed tissues and a large collection of histopathology slides from all the studies, plus about 20,000 individual solutions derived from donated tissues. These tissues and tissue related materials are made available to other investigators for legitimate research purposes. Ratios of the concentration of actinides in various tissues have been used to evaluate the biokinetics, and retention half times of plutonium and americium. Retention half times for plutonium in various soft tissues range from 10-20 y except for the testes for which a retention half time of 58 y was observed. For americium, the retention half time in various soft tissues studied was 2.2-3.5 y.« less

  15. First results of the CINDI-2 semi-blind MAX-DOAS intercomparison

    NASA Astrophysics Data System (ADS)

    Kreher, Karin; van Roozendael, Michel; Hendrick, Francois; Apituley, Arnoud; Friess, Udo; Lampel, Johannes; Piters, Ankie; Richter, Andreas; Wagner, Thomas; Cindi-2 Participants, All

    2017-04-01

    The second Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI-2) took place at the Cabauw Experimental Site for Atmospheric Research (CESAR; Utrecht area, The Netherlands) from 25 August until 7 October 2016. The goals of this inter-comparison campaign are to support the creation of high-quality ground-based data sets (e.g. to provide reliable long-term time series for trend analysis and satellite data validation), to characterise and better understand the differences between a large number of MAX-DOAS and DOAS instruments and analysis methods, and to contribute to a harmonisation of the measurement settings and retrieval methods. During a time period of 17 days, from 12 to 28 September 2016, a formal semi-blind intercomparison was held following a detailed measurement protocol. The development of this protocol was based on the experience gained during the first CINDI campaign held in 2009 as well as more recent projects and campaigns such as the MADCAT campaign in Mainz, Germany, in 2013. Strong emphasis was put on the careful synchronisation of the measurement sequence and on exact alignment of the elevation angles using horizon scans and lamp measurements. In this presentation, we provide an overview and some highlights of the MAX-DOAS semi-blind intercomparison campaign. We will introduce the participating groups, their instruments and the measurement protocol details, and then summarize the campaign outcomes to date. The CINDI-2 data sets have been investigated using a range of diagnostics including comparisons of daily time series and relative differences between the data sets, regression analysis and correlation plots. The data products so far investigated are NO2 (nitrogen dioxide) in the UV and visible wavelength region, O4 (oxygen dimer) in the same two wavelength intervals, O3 (ozone) in the UV and visible wavelength region, HCHO (formaldehyde) and NO2 in an additional (smaller) wavelength range in the visible. The results based on the regression analysis are presented in summary plots and tables, addressing MAX-DOAS and twilight zenith sky measurements separately. Further information on instrumental details such as the alignment of the viewing direction and elevation and the field of view are also summarized and included in the overall interpretation.

  16. Atmospheric Correction Inter-comparison Exercise (ACIX)

    NASA Astrophysics Data System (ADS)

    Vermote, E.; Doxani, G.; Gascon, F.; Roger, J. C.; Skakun, S.

    2017-12-01

    The free and open data access policy to Landsat-8 (L-8) and Sentinel-2 (S-2) satellite imagery has encouraged the development of atmospheric correction (AC) approaches for generating Bottom-of-Atmosphere (BOA) products. Several entities have started to generate (or plan to generate in the short term) BOA reflectance products at global scale for L-8 and S-2 missions. To this end, the European Space Agency (ESA) and National Aeronautics and Space Administration (NASA) have initiated an exercise on the inter-comparison of the available AC processors. The results of the exercise are expected to point out the strengths and weaknesses, as well as communalities and discrepancies of various AC processors, in order to suggest and define ways for their further improvement. In particular, 11 atmospheric processors from five different countries participate in ACIX with the aim to inter-compare their performance when applied to L-8 and S-2 data. All the processors should be operational without requiring parametrization when applied on different areas. A protocol describing in details the inter-comparison metrics and the test dataset based on the AERONET sites has been agreed unanimously during the 1st ACIX workshop in June 2016. In particular, a basic and an advanced run of each of the processor were requested in the frame of ACIX, with the aim to draw robust and reliable conclusions on the processors' performance. The protocol also describes the comparison metrics of the aerosol optical thickness and water vapour products of the processors with the corresponding AERONET measurements. Moreover, concerning the surface reflectances, the inter-comparison among the processors is defined, as well as the comparison with the MODIS surface reflectance and with a reference surface reflectance product. Such a reference product will be obtained using the AERONET characterization of the aerosol (size distribution and refractive indices) and an accurate radiative transfer code. The inter-comparison outcomes were presented and discussed among the ACIX participants in the 2nd ACIX workshop, which was held on 11-12 April 2017 (ESRIN/ESA) and a detailed report was compiled. The proposed presentation is an opportunity for the user community to be informed about the ACIX results and conclusions.

  17. Radiance and Jacobian Intercomparison of Radiative Transfer Models Applied to HIRS and AMSU Channels

    NASA Technical Reports Server (NTRS)

    Garand, L.; Turner, D. S.; Larocque, M.; Bates, J.; Boukabara, S.; Brunel, P.; Chevallier, F.; Deblonde, G.; Engelen, R.; Hollingshead, M.; hide

    2000-01-01

    The goals of this study are the evaluation of current fast radiative transfer models (RTMs) and line-by-line (LBL) models. The intercomparison focuses on the modeling of 11 representative sounding channels routinely used at numerical weather prediction centers: 7 HIRS (High-resolution Infrared Sounder) and 4 AMSU (Advanced Microwave Sounding Unit) channels. Interest in this topic was evidenced by the participation of 24 scientists from 16 institutions. An ensemble of 42 diverse atmospheres was used and results compiled for 19 infrared models and 10 microwave models, including several LBL RTMs. For the first time, not only radiances, but also Jacobians (of temperature, water vapor and ozone) were compared to various LBL models for many channels. In the infrared, LBL models typically agree to within 0.05-0.15 K (standard deviation) in terms of top-of-the-atmosphere brightness temperature (BT). Individual differences up to 0.5 K still exist, systematic in some channels, and linked to the type of atmosphere in others. The best fast models emulate LBL BTs to within 0.25 K, but no model achieves this desirable level of success for all channels. The ozone modeling is particularly challenging, In the microwave, fast models generally do quite well against the LBL model to which they were tuned. However significant differences were noted among LBL models, Extending the intercomparison to the Jacobians proved very useful in detecting subtle and more obvious modeling errors. In addition, total and single gas optical depths were calculated, which provided additional insight on the nature of differences. Recommendations for future intercomparisons are suggested.

  18. Radiance and Jacobian Intercomparison of Radiative Transfer Models Applied to HIRS and AMSU Channels

    NASA Technical Reports Server (NTRS)

    Garand, L.; Turner, D. S.; Larocque, M.; Bates, J.; Boukabara, S.; Brunel, P.; Chevallier, F.; Deblonde, G.; Engelen, R.; Atlas, Robert (Technical Monitor)

    2000-01-01

    The goals of this study are the evaluation of current fast radiative transfer models (RTMs) and line-by-line (LBL) models. The intercomparison focuses on the modeling of 11 representative sounding channels routinely used at numerical weather prediction centers: seven HIRS (High-resolution Infrared Sounder) and four AMSU (Advanced Microwave Sounding Unit) channels. Interest in this topic was evidenced by the participation of 24 scientists from 16 institutions. An ensemble of 42 diverse atmospheres was used and results compiled for 19 infrared models and 10 microwave models, including several LBL RTMs. For the first time, not only radiances, but also Jacobians (of temperature, water vapor, and ozone) were compared to various LBL models for many channels. In the infrared, LBL models typically agree to within 0.05-0.15 K (standard deviation) in terms of top-of-the-atmosphere brightness temperature (BT). Individual differences up to 0.5 K still exist, systematic in some channels, and linked to the type of atmosphere in others. The best fast models emulate LBL BTs to within 0.25 K, but no model achieves this desirable level of success for all channels. The ozone modeling is particularly challenging. In the microwave, fast models generally do quite well against the LBL model to which they were tuned. However significant differences were noted among LBL models. Extending the intercomparison to the Jacobians proved very useful in detecting subtle and more obvious modeling errors. In addition, total and single gas optical depths were calculated, which provided additional insight on the nature of differences. Recommendations for future intercomparisons are suggested.

  19. The 1997 North American Interagency Intercomparison of Ultraviolet Spectroradiometers Including Narrowband Filter Radiometers

    PubMed Central

    Lantz, Kathleen; Disterhoft, Patrick; Early, Edward; Thompson, Ambler; DeLuisi, John; Berndt, Jerry; Harrison, Lee; Kiedron, Peter; Ehramjian, James; Bernhard, Germar; Cabasug, Lauriana; Robertson, James; Mou, Wanfeng; Taylor, Thomas; Slusser, James; Bigelow, David; Durham, Bill; Janson, George; Hayes, Douglass; Beaubien, Mark; Beaubien, Arthur

    2002-01-01

    The fourth North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held September 15 to 25, 1997 at Table Mountain outside of Boulder, Colorado, USA. Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. The main purpose of the Intercomparison was to assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks. This Intercomparison was coordinated by NIST and NOAA, and included participants from the ASRC, EPA, NIST, NSF, SERC, USDA, and YES. The UV measuring instruments included scanning spectroradiometers, spectrographs, narrow band multi-filter radiometers, and broadband radiometers. Instruments were characterized for wavelength accuracy, bandwidth, stray-light rejection, and spectral irradiance responsivity. The spectral irradiance responsivity was determined two to three times outdoors to assess temporal stability. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST traceable standard lamp, and a simple convolution technique with a Gaussian slit-scattering function to account for the different bandwidths of the instruments, the measured solar irradiance from the spectroradiometers excluding the filter radiometers at 16.5 h UTC had a relative standard deviation of ±4 % for wavelengths greater than 305 nm. The relative standard deviation for the solar irradiance at 16.5 h UTC including the filter radiometer was ±4 % for filter functions above 300 nm. PMID:27446717

  20. GMMIP (v1.0) contribution to CMIP6: Global Monsoons Model Inter-comparison Project

    NASA Astrophysics Data System (ADS)

    Zhou, Tianjun; Turner, Andrew G.; Kinter, James L.; Wang, Bin; Qian, Yun; Chen, Xiaolong; Wu, Bo; Wang, Bin; Liu, Bo; Zou, Liwei; He, Bian

    2016-10-01

    The Global Monsoons Model Inter-comparison Project (GMMIP) has been endorsed by the panel of Coupled Model Inter-comparison Project (CMIP) as one of the participating model inter-comparison projects (MIPs) in the sixth phase of CMIP (CMIP6). The focus of GMMIP is on monsoon climatology, variability, prediction and projection, which is relevant to four of the "Grand Challenges" proposed by the World Climate Research Programme. At present, 21 international modeling groups are committed to joining GMMIP. This overview paper introduces the motivation behind GMMIP and the scientific questions it intends to answer. Three tiers of experiments, of decreasing priority, are designed to examine (a) model skill in simulating the climatology and interannual-to-multidecadal variability of global monsoons forced by the sea surface temperature during historical climate period; (b) the roles of the Interdecadal Pacific Oscillation and Atlantic Multidecadal Oscillation in driving variations of the global and regional monsoons; and (c) the effects of large orographic terrain on the establishment of the monsoons. The outputs of the CMIP6 Diagnostic, Evaluation and Characterization of Klima experiments (DECK), "historical" simulation and endorsed MIPs will also be used in the diagnostic analysis of GMMIP to give a comprehensive understanding of the roles played by different external forcings, potential improvements in the simulation of monsoon rainfall at high resolution and reproducibility at decadal timescales. The implementation of GMMIP will improve our understanding of the fundamental physics of changes in the global and regional monsoons over the past 140 years and ultimately benefit monsoons prediction and projection in the current century.

  1. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario.

    PubMed

    Vives I Batlle, J; Beresford, N A; Beaugelin-Seiller, K; Bezhenar, R; Brown, J; Cheng, J-J; Ćujić, M; Dragović, S; Duffa, C; Fiévet, B; Hosseini, A; Jung, K T; Kamboj, S; Keum, D-K; Kryshev, A; LePoire, D; Maderich, V; Min, B-I; Periáñez, R; Sazykina, T; Suh, K-S; Yu, C; Wang, C; Heling, R

    2016-03-01

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of (90)Sr, (131)I and (137)Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and which uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. New Sentinel-2 radiometric validation approaches (SEOM program)

    NASA Astrophysics Data System (ADS)

    Bruniquel, Véronique; Lamquin, Nicolas; Ferron, Stéphane; Govaerts, Yves; Woolliams, Emma; Dilo, Arta; Gascon, Ferran

    2016-04-01

    SEOM is an ESA program element whose one of the objectives aims at launching state-of-the-art studies for the scientific exploitation of operational missions. In the frame of this program, ESA awarded ACRI-ST and its partners Rayference and National Physical Laboratory (NPL) early 2016 for a R&D study on the development and intercomparison of algorithms for validating the Sentinel-2 radiometric L1 data products beyond the baseline algorithms used operationally in the frame of the S2 Mission Performance Centre. In this context, several algorithms have been proposed and are currently in development: The first one is based on the exploitation of Deep Convective Cloud (DCC) observations over ocean. This method allows an inter-band radiometry validation from the blue to the NIR (typically from B1 to B8a) from a reference band already validated for example with the well-known Rayleigh method. Due to their physical properties, DCCs appear from the remote sensing point of view to have bright and cold tops and they can be used as invariant targets to monitor the radiometric response degradation of reflective solar bands. The DCC approach is statistical i.e. the method shall be applied on a large number of measurements to derive reliable statistics and decrease the impact of the perturbing contributors. The second radiometric validation method is based on the exploitation of matchups combining both concomitant in-situ measurements and Sentinel-2 observations. The in-situ measurements which are used here correspond to measurements acquired in the frame of the RadCalNet networks. The validation is performed for the Sentinel-2 bands similar to the bands of the instruments equipping the validation site. The measurements from the Cimel CE 318 12-filters BRDF Sun Photometer installed recently in the Gobabeb site near the Namib desert are used for this method. A comprehensive verification of the calibration requires an analysis of MSI radiances over the full dynamic range, including low radiances, as extreme values are more subject to instrument response non-linearity. The third method developed in the frame of this project aims to address this point. It is based on a comparison of Sentinel-2 observations over coastal waters which have low radiometry and corresponding Radiative Transfer (RT) simulations using AERONET-OC measurements. Finally, a last method is developed using RadCalNet measurements and Sentinel-2 observations to validate the radiometry of mid/low resolution sensors such as Sentinel-3/OLCI. The RadCalNet measurements are transferred from the RadCalNet sites to Pseudo Invariant Calibration Sites (PICS) using Sentinel-2, and then these larger sites are used to validate mid- and low-resolution sensors to the RadCalNet reference. For all the developed methods, an uncertainty budget is derived following QA4EO guidelines. A last step of this ESA project is dedicated to an Inter-comparison Workshop open to entities involved in Sentinel-2 radiometric validation activities. Blind inter-comparison tests over a series of images will be proposed and the results will be discussed during the workshop.

  3. Status report on the Zagreb Radiocarbon Laboratory - AMS and LSC results of VIRI intercomparison samples

    NASA Astrophysics Data System (ADS)

    Sironić, Andreja; Krajcar Bronić, Ines; Horvatinčić, Nada; Barešić, Jadranka; Obelić, Bogomil; Felja, Igor

    2013-01-01

    A new line for preparation of the graphite samples for 14C dating by Accelerator Mass Spectrometry (AMS) in the Zagreb Radiocarbon Laboratory has been validated by preparing graphite from various materials distributed within the Fifth International Radiocarbon Intercomparison (VIRI) study. 14C activity of prepared graphite was measured at the SUERC AMS facility. The results are statistically evaluated by means of the z-score and u-score values. The mean z-score value of 28 prepared VIRI samples is (0.06 ± 0.23) showing excellent agreement with the consensus VIRI values. Only one sample resulted in the u-score value above the limit of acceptability (defined for the confidence interval of 99%) and this was probably caused by a random contamination of the graphitization rig. After the rig had been moved to the new adapted and isolated room, all u-score values laid within the acceptable limits. Our LSC results of VIRI intercomparison samples are also presented and they are all accepted according to the u-score values.

  4. An Overview of Measurement Comparisons from the INTEX-B/MILAGRO Airborne Field Campaign

    NASA Technical Reports Server (NTRS)

    Kleb, Mary M.; Chen, Gao; Crawford, James H.; Flocke, Frank M.; Brown, Clyde C.

    2011-01-01

    As part of the NASA's INTEX-B mission, the NASA DC-8 and NSF C-130 conducted three wing-tip to wing-tip comparison flights. The intercomparison flights sampled a variety of atmospheric conditions (polluted urban, non-polluted, marine boundary layer, clean and polluted free troposphere). These comparisons form a basis to establish data consistency, but also should also be viewed as a continuation of efforts aiming to better understand and reduce measurement differences as identified in earlier field intercomparison exercises. This paper provides a comprehensive overview of 140 intercomparisons of data collected as well as a record of the measurement consistency demonstrated during INTEX-B. It is the primary goal to provide necessary information for the future research to determine if the observations from different INTEX-B platforms/instrument are consistent within the PI reported uncertainties and used in integrated analysis. This paper may also contribute to the formulation strategy for future instrument developments. For interpretation and most effective use of these results, the reader is strongly urged to consult with the instrument principle investigator.

  5. Ice Sheet Model Intercomparison Project (ISMIP6) contribution to CMIP6

    PubMed Central

    Nowicki, Sophie M.J.; Payne, Tony; Larour, Eric; Seroussi, Helene; Goelzer, Heiko; Lipscomb, William; Gregory, Jonathan; Abe-Ouchi, Ayako; Shepherd, Andrew

    2018-01-01

    Reducing the uncertainty in the past, present and future contribution of ice sheets to sea-level change requires a coordinated effort between the climate and glaciology communities. The Ice Sheet Model Intercomparison Project for CMIP6 (ISMIP6) is the primary activity within the Coupled Model Intercomparison Project – phase 6 (CMIP6) focusing on the Greenland and Antarctic Ice Sheets. In this paper, we describe the framework for ISMIP6 and its relationship to other activities within CMIP6. The ISMIP6 experimental design relies on CMIP6 climate models and includes, for the first time within CMIP, coupled ice sheet – climate models as well as standalone ice sheet models. To facilitate analysis of the multi-model ensemble and to generate a set of standard climate inputs for standalone ice sheet models, ISMIP6 defines a protocol for all variables related to ice sheets. ISMIP6 will provide a basis for investigating the feedbacks, impacts, and sea-level changes associated with dynamic ice sheets and for quantifying the uncertainty in ice-sheet-sourced global sea-level change. PMID:29697697

  6. Results of the Greenland ice sheet model initialisation experiments: ISMIP6 - initMIP-Greenland

    NASA Astrophysics Data System (ADS)

    Goelzer, Heiko; Nowicki, Sophie; Edwards, Tamsin; Beckley, Matthew

    2017-04-01

    Ice sheet model initialisation has a large effect on projected future sea-level contributions and gives rise to important uncertainties. The goal of this intercomparison exercise for the continental-scale Greenland ice sheet is therefore to compare, evaluate and improve the initialisation techniques used in the ice sheet modelling community. The initMIP-Greenland project is the first in a series of ice sheet model intercomparison activities within ISMIP6 (Ice Sheet Model Intercomparison Project for CMIP6). The experimental set-up has been designed to allow comparison of the initial present-day state of the Greenland ice sheet between participating models and against observations. Furthermore, the initial states are tested with two schematic forward experiments to evaluate the initialisation in terms of model drift (forward run without any forcing) and response to a large perturbation (prescribed surface mass balance anomaly). We present and discuss results that highlight the wide diversity of data sets, boundary conditions and initialisation techniques used in the community to generate initial states of the Greenland ice sheet.

  7. Ice Sheet Model Intercomparison Project (ISMIP6) Contribution to CMIP6

    NASA Technical Reports Server (NTRS)

    Nowicki, Sophie M. J.; Payne, Tony; Larour, Eric; Seroussi, Helene; Goelzer, Heiko; Lipscomb, William; Gregory, Jonathan; Abe-Ouchi, Ayako; Shepherd, Andrew

    2016-01-01

    Reducing the uncertainty in the past, present, and future contribution of ice sheets to sea-level change requires a coordinated effort between the climate and glaciology communities. The Ice Sheet Model Intercomparison Project for CMIP6 (ISMIP6) is the primary activity within the Coupled Model Intercomparison Project phase 6 (CMIP6) focusing on the Greenland and Antarctic ice sheets. In this paper, we describe the framework for ISMIP6 and its relationship with other activities within CMIP6. The ISMIP6 experimental design relies on CMIP6 climate models and includes, for the first time within CMIP, coupled ice-sheetclimate models as well as standalone ice-sheet models. To facilitate analysis of the multi-model ensemble and to generate a set of standard climate inputs for standalone ice-sheet models, ISMIP6 defines a protocol for all variables related to ice sheets. ISMIP6 will provide a basis for investigating the feedbacks, impacts, and sea-level changes associated with dynamic ice sheets and for quantifying the uncertainty in ice-sheet-sourced global sea-level change.

  8. An International Marine-Atmospheric 222Rn Measurement Intercomparison in Bermuda Part I: NIST Calibration and Methodology for Standardized Sample Additions

    PubMed Central

    Collé, R.; Unterweger, M. P.; Hodge, P. A.; Hutchinson, J. M. R.

    1996-01-01

    As part of an international 222Rn measurement intercomparison conducted at Bermuda in October 1991, NIST provided standardized sample additions of known, but undisclosed (“blind”) 222Rn concentrations that could be related to U.S. national standards. The standardized sample additions were obtained with a calibrated 226Ra source and a specially-designed manifold used to obtain well-known dilution factors from simultaneous flow-rate measurements. The additions were introduced over sampling periods of several hours (typically 4 h) into a common streamline on a sampling tower used by the participating laboratories for their measurements. The standardized 222Rn activity concentrations for the intercomparison ranged from approximately 2.5 Bq · m−3 to 35 Bq · m−3 (of which the lower end of this range approached concentration levels for ambient Bermudian air) and had overall uncertainties, approximating a 3 standard deviation uncertainty interval, of about 6 % to 13 %. This paper describes the calibration and methodology for the standardized sample additions. PMID:27805090

  9. Soundings from SGP, June 2014 Sonde Comparison Study

    DOE Data Explorer

    Jensen, Michael

    2015-03-06

    In early June 2014, a radiosonde intercomparison trial was undertaken at the SGP Central Facility site with the goal of quantifying the relative performance of the RS92-SGP/MW31 and RS41-SG/MW41 radiosondes/systems. The June time period at SGP represents a springtime mid-latitude convective environment where the extensive remote sensing observations at the SGP site were used to further quantify the environment during the intercomparison. Over the course of five days (3 - 8 June) a total of 20 balloon launches were completed with efforts to sample the entire diurnal cycle and a variety of cloud conditions

  10. Dose evaluation in criticality accidents using response of Panasonic TL personal dosemeters (UD-809/UD-802).

    PubMed

    Zeyrek, C T; Gündüz, H

    2012-09-01

    This study gives the results of dosimetry measurements carried out in the Silène reactor at Valduc (France) with neutron and photon personal thermoluminescence dosemeters (TLDs) in mixed neutron and gamma radiation fields, in the frame of the international accident dosimetry intercomparison programme in 2002. The intercomparison consisted of a series of three irradiation scenarios. The scenarios took place at the Valduc site (France) by using the Silène experimental reactor. For neutron and photon dosimetry, Panasonic model UD-809 and UD-802 personal TLDs were used together.

  11. Inter-comparison of boron concentration measurements at INFN-University of Pavia (Italy) and CNEA (Argentina).

    PubMed

    Portu, Agustina; Postuma, Ian; Gadan, Mario Alberto; Saint Martin, Gisela; Olivera, María Silvina; Altieri, Saverio; Protti, Nicoletta; Bortolussi, Silva

    2015-11-01

    An inter-comparison of three boron determination techniques was carried out between laboratories from INFN-University of Pavia (Italy) and CNEA (Argentina): alpha spectrometry (alpha-spect), neutron capture radiography (NCR) and quantitative autoradiography (QTA). Samples of different nature were analysed: liquid standards, liver homogenates and tissue samples from different treatment protocols. The techniques showed a good agreement in a concentration range of interest in BNCT (1-100ppm), thus demonstrating their applicability as precise methods to quantify boron and determine its distribution in tissues. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. International Intercomparison of Regular Transmittance Scales

    NASA Astrophysics Data System (ADS)

    Eckerle, K. L.; Sutter, E.; Freeman, G. H. C.; Andor, G.; Fillinger, L.

    1990-01-01

    An intercomparison of the regular spectral transmittance scales of NIST, Gaithersburg, MD (USA); PTB, Braunschweig (FRG); NPL, Teddington, Middlesex (UK); and OMH, Budapest (H) was accomplished using three sets of neutral glass filters with transmittances ranging from approximately 0.92 to 0.001. The difference between the results from the reference spectrophotometers of the laboratories was generally smaller than the total uncertainty of the interchange. The relative total uncertainty ranges from 0.05% to 0.75% for transmittances from 0.92 to 0.001. The sample-induced error was large - contributing 40% or more of the total except in a few cases.

  13. Soil sampling strategies: evaluation of different approaches.

    PubMed

    de Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Mufato, Renzo; Sartori, Giuseppe; Stocchero, Giulia

    2008-11-01

    The National Environmental Protection Agency of Italy (APAT) performed a soil sampling intercomparison, inviting 14 regional agencies to test their own soil sampling strategies. The intercomparison was carried out at a reference site, previously characterised for metal mass fraction distribution. A wide range of sampling strategies, in terms of sampling patterns, type and number of samples collected, were used to assess the mean mass fraction values of some selected elements. The different strategies led in general to acceptable bias values (D) less than 2sigma, calculated according to ISO 13258. Sampling on arable land was relatively easy, with comparable results between different sampling strategies.

  14. Study of water masses variability in the Mediterranean Sea using in-situ data / NEMO-Med12 model.

    NASA Astrophysics Data System (ADS)

    Margirier, Félix; Testor, Pierre; Mortier, Laurent; Arsouze, Thomas; Bosse, Anthony; Houpert, Loic; Hayes, Dan

    2016-04-01

    In the past 10 years, numerous observation programs in the Mediterranean deployed autonomous platforms (moorings, argo floats, gliders) and thus considerably increased the number of in-situ observations and the data coverage. In this study, we analyse time series built with profile data on interannual scales. Sorting data in regional boxes, we follow the evolution of different water masses in the basin and generate indexes to characterize their evolution. We then put those indexes in relation with external (atmospheric) forcings and present an intercomparison with the NEMO-Med12 model to estimate both the skill of the model and the relevance of the data-sampling in reproducing the evolution of water masses properties.

  15. Assessing Impacts of Climate Change on Food Security Worldwide

    NASA Technical Reports Server (NTRS)

    Rosenzweig, Cynthia E.; Antle, John; Elliott, Joshua

    2015-01-01

    The combination of a warming Earth and an increasing population will likely strain the world's food systems in the coming decades. Experts involved with the Agricultural Model Intercomparison and Improvement Project (AgMIP) focus on quantifying the changes through time. AgMIP, a program begun in 2010, involves about 800 climate scientists, economists, nutritionists, information technology specialists, and crop and livestock experts. In mid-September 2015, the Aspen Global Change Institute convened an AgMIP workshop to draft plans and protocols for assessing global- and regional-scale modeling of crops, livestock, economics, and nutrition across major agricultural regions worldwide. The goal of this Coordinated Global and Regional Integrated Assessments (CGRA) project is to characterize climate effects on large- and small-scale farming systems.

  16. Intercomparison of American and Soviet stellar image motion monitors

    NASA Astrophysics Data System (ADS)

    Forbes, Fred F.; Kutyrev, Aleksandr

    1990-07-01

    Astronomical observatory site testing programs in the USA and USSR have used a variety of stellar image motion monitors in the selection of the best sites for the construction of large (6 to 10 meter) telescopes. While there appears to be a reasonable agreement between microthermal and sodar results for the better sites in both countries, there remain unexplained inconsistencies in measured seeing, especially at Mauna Kea, Hawaii and Mount Sanglok. The photoelectric seeing monitor built by Scheglov (1984) of the Moscow Sternberg Institute, and the National Optical Astronomy Observatories site-survey intensified CID seeing monitor have been mounted on the same telescope. Simultaneous image motion data recorded are compared for single images as differential measurements of dual images.

  17. Rapid and accurate assessment of the activity measurements in Brazilian hospitals and clinics.

    PubMed

    de Oliveira, A E; Iwahara, A; da Cruz, P A L; da Silva, C J; de Araújo, E B; Mengatti, J; da Silva, R L; Trindade, O L

    2018-04-01

    Traceability in Nuclear Medicine Service (NMS) measurements was checked by the Institute of Radioprotection and Dosimetry (IRD) through the Institute of Energy and Nuclear Research (IPEN). In 2016, IRD ran an intercomparison program and invited Brazilian NMS authorized to administer 131 I to patients. Sources of 131 I were distributed to 33 NMSs. Three other sources from the same solution were sent to IRD, after measurement at IPEN. These sources were calibrated in the IRD reference system. A correction factor of 1.013 was obtained. Ninety percent of the NMS comparisons results are within ±10% of the National Laboratory of Metrology of Ionizing Radiation (LNMRI) value, the Brazilian legal requirement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Atmospheric and Spectroscopic Research in the Far Infrared

    NASA Technical Reports Server (NTRS)

    Park, Kwangjai

    2001-01-01

    The University of Oregon (UO) was a participant in a number of far infrared spectroscopic projects over the past three decades. These include Sub-millimeter Infrared Balloon Experiment (SIBEX), the Balloon Intercomparison Campaign (BIC), and the Infrared Balloon Experiment (IBEX). In addition to these field studies, the UO program contained a detector research component and a laboratory spectroscopy element. Through a productive collaboration with Dr. Carli's group in Italy, with Prof. Ade's group in England and with Dr. Chance of Harvard-Smithsonian, we have made substantial contributions to the development of far infrared spectroscopy as a mature measurement technology for the atmospheric science. This report summarizes the activities during the latest grant period, covering the span from February 22, 1998 to February 21, 2002.

  19. Aerosol chemistry in GLOBE

    NASA Technical Reports Server (NTRS)

    Clarke, Antony D.; Rothermel, Jeffry; Jarzembski, Maurice A.

    1993-01-01

    This task addresses the measurement and understanding of the physical and chemical properties of aerosol in remote regions that are responsible for aerosol backscatter at infrared wavelengths. Because it is representative of other clean areas, the remote Pacific is of extreme interest. Emphasis is on the determination size dependent aerosol properties that are required for modeling backscatter at various wavelengths and upon those features that may be used to help understand the nature, origin, cycling and climatology of these aerosols in the remote troposphere. Empirical relationships will be established between lidar measurements and backscatter derived from the aerosol microphysics as required by the NASA Doppler Lidar Program. This will include the analysis of results from the NASA GLOBE Survey Mission Flight Program. Additional instrument development and deployment will be carried out in order to extend and refine this data base. Identified activities include participation in groundbased and airborne experiments. Progress to date includes participation in, analysis of, and publication of results from Mauna Loa Backscatter Intercomparison Experiment (MABIE) and Global Backscatter Experiment (GLOBE).

  20. Marine ARM GPCI Investigation of Clouds Bridge Display Field Campaign Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reynolds, R. Michael; Lewis, Ernie

    2016-09-01

    At the beginning of the U.S. Department of Energy (DOE) Marine Atmospheric Radiation Measurement (ARM) Climate Research Facility Global Energy and Water Experiment (GEWEX) Cloud System Study (GCSS) Pacific Cross-Section Intercomparison (GPCI) Investigation of Clouds (MAGIC) experiment, we recognized that the crew on the ship’s bridge would like to see a display of the meteorological data that was being collected. While a display on the bridge would be marginally useful to the science, it was decided to make a display for the bridge. A display was programmed in Lab View and a personal computer (PC) was set up in themore » bridge. This remained in operation until the ship went to dry dock for upgrades and service. Part of the upgrade was a new meteorological system for the ship. After this time there was no need for the ARM display and so it was not re-installed for the remainder of the program.« less

  1. Multibiodose radiation emergency triage categorization software.

    PubMed

    Ainsbury, Elizabeth A; Barnard, Stephen; Barrios, Lleonard; Fattibene, Paola; de Gelder, Virginie; Gregoire, Eric; Lindholm, Carita; Lloyd, David; Nergaard, Inger; Rothkamm, Kai; Romm, Horst; Scherthan, Harry; Thierens, Hubert; Vandevoorde, Charlot; Woda, Clemens; Wojcik, Andrzej

    2014-07-01

    In this note, the authors describe the MULTIBIODOSE software, which has been created as part of the MULTIBIODOSE project. The software enables doses estimated by networks of laboratories, using up to five retrospective (biological and physical) assays, to be combined to give a single estimate of triage category for each individual potentially exposed to ionizing radiation in a large scale radiation accident or incident. The MULTIBIODOSE software has been created in Java. The usage of the software is based on the MULTIBIODOSE Guidance: the program creates a link to a single SQLite database for each incident, and the database is administered by the lead laboratory. The software has been tested with Java runtime environment 6 and 7 on a number of different Windows, Mac, and Linux systems, using data from a recent intercomparison exercise. The Java program MULTIBIODOSE_1.0.jar is freely available to download from http://www.multibiodose.eu/software or by contacting the software administrator: MULTIBIODOSE-software@gmx.com.

  2. GMMIP (v1.0) contribution to CMIP6: Global Monsoons Model Inter-comparison Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Tianjun; Turner, Andrew G.; Kinter, James L.

    The Global Monsoons Model Inter-comparison Project (GMMIP) has been endorsed by the panel of Coupled Model Inter-comparison Project (CMIP) as one of the participating model inter-comparison projects (MIPs) in the sixth phase of CMIP (CMIP6). The focus of GMMIP is on monsoon climatology, variability, prediction and projection, which is relevant to four of the “Grand Challenges” proposed by the World Climate Research Programme. At present, 21 international modeling groups are committed to joining GMMIP. This overview paper introduces the motivation behind GMMIP and the scientific questions it intends to answer. Three tiers of experiments, of decreasing priority, are designed to examinemore » (a) model skill in simulating the climatology and interannual-to-multidecadal variability of global monsoons forced by the sea surface temperature during historical climate period; (b) the roles of the Interdecadal Pacific Oscillation and Atlantic Multidecadal Oscillation in driving variations of the global and regional monsoons; and (c) the effects of large orographic terrain on the establishment of the monsoons. The outputs of the CMIP6 Diagnostic, Evaluation and Characterization of Klima experiments (DECK), “historical” simulation and endorsed MIPs will also be used in the diagnostic analysis of GMMIP to give a comprehensive understanding of the roles played by different external forcings, potential improvements in the simulation of monsoon rainfall at high resolution and reproducibility at decadal timescales. The implementation of GMMIP will improve our understanding of the fundamental physics of changes in the global and regional monsoons over the past 140 years and ultimately benefit monsoons prediction and projection in the current century.« less

  3. Dosimetry audits and intercomparisons in radiotherapy: A Malaysian profile

    NASA Astrophysics Data System (ADS)

    M. Noor, Noramaliza; Nisbet, A.; Hussein, M.; Chu S, Sarene; Kadni, T.; Abdullah, N.; Bradley, D. A.

    2017-11-01

    Quality audits and intercomparisons are important in ensuring control of processes in any system of endeavour. Present interest is in control of dosimetry in teletherapy, there being a need to assess the extent to which there is consistent radiation dose delivery to the patient. In this study we review significant factors that impact upon radiotherapy dosimetry, focusing upon the example situation of radiotherapy delivery in Malaysia, examining existing literature in support of such efforts. A number of recommendations are made to provide for increased quality assurance and control. In addition to this study, the first level of intercomparison audit i.e. measuring beam output under reference conditions at eight selected Malaysian radiotherapy centres is checked; use being made of 9 μm core diameter Ge-doped silica fibres (Ge-9 μm). The results of Malaysian Secondary Standard Dosimetry Laboratory (SSDL) participation in the IAEA/WHO TLD postal dose audit services during the period between 2011 and 2015 will also been discussed. In conclusion, following review of the development of dosimetry audits and the conduct of one such exercise in Malaysia, it is apparent that regular periodic radiotherapy audits and intercomparison programmes should be strongly supported and implemented worldwide. The programmes to-date demonstrate these to be a good indicator of errors and of consistency between centres. A total of ei+ght beams have been checked in eight Malaysian radiotherapy centres. One out of the eight beams checked produced an unacceptable deviation; this was found to be due to unfamiliarity with the irradiation procedures. Prior to a repeat measurement, the mean ratio of measured to quoted dose was found to be 0.99 with standard deviation of 3%. Subsequent to the repeat measurement, the mean distribution was 1.00, and the standard deviation was 1.3%.

  4. Intercomparison of mid latitude storm diagnostics (IMILAST) - synthesis of project results

    NASA Astrophysics Data System (ADS)

    Neu, Urs

    2017-04-01

    The analysis of the occurrence of mid-latitude storms is of great socio-economical interest due to their vast and destructive impacts. However, a unique definition of cyclones is missing, and therefore the definition of what a cyclone is as well as quantifying its strength contains subjective choices. Existing automatic cyclone identification and tracking algorithms are based on different definitions and use diverse characteristics, e.g. data transformation, metrics used for cyclone identification, cyclone identification procedures or tracking methods. The project IMILAST systematically compares different cyclone detection and tracking methods, with the aim to comprehensively assess the influence of different algorithms on cyclone climatologies, temporal trends of frequency, strength or other characteristics of cyclones and thus quantify systematic uncertainties in mid-latitudinal storm identification and tracking. The three main intercomparison experiments used the ERA-interim reanalysis as a common input data set and focused on differences between the methods with respect to number, track density, life cycle characteristics, and trend patterns on the one hand and potential differences of the long-term climate change signal of cyclonic activity between the methods on the other hand. For the third experiment, the intercomparison period has been extended to a 30 year period from 1979 to 2009 and focuses on more specific aspects, such as parameter sensitivities, the comparison of automated to manual tracking sets, regional analysis (regional trends, Arctic and Antarctic cyclones, cyclones in the Mediterranean) or specific phenomena like splitting and merging of cyclones. In addition, the representation of storms and their characteristics in reanalysis data sets is examined to further enhance the knowledge on uncertainties related to storm occurrence. This poster presents a synthesis of the main results from the intercomparison activities within IMILAST.

  5. Global Intercomparison of 12 Land Surface Heat Flux Estimates

    NASA Technical Reports Server (NTRS)

    Jimenez, C.; Prigent, C.; Mueller, B.; Seneviratne, S. I.; McCabe, M. F.; Wood, E. F.; Rossow, W. B.; Balsamo, G.; Betts, A. K.; Dirmeyer, P. A.; hide

    2011-01-01

    A global intercomparison of 12 monthly mean land surface heat flux products for the period 1993-1995 is presented. The intercomparison includes some of the first emerging global satellite-based products (developed at Paris Observatory, Max Planck Institute for Biogeochemistry, University of California Berkeley, University of Maryland, and Princeton University) and examples of fluxes produced by reanalyses (ERA-Interim, MERRA, NCEP-DOE) and off-line land surface models (GSWP-2, GLDAS CLM/ Mosaic/Noah). An intercomparison of the global latent heat flux (Q(sub le)) annual means shows a spread of approx 20 W/sq m (all-product global average of approx 45 W/sq m). A similar spread is observed for the sensible (Q(sub h)) and net radiative (R(sub n)) fluxes. In general, the products correlate well with each other, helped by the large seasonal variability and common forcing data for some of the products. Expected spatial distributions related to the major climatic regimes and geographical features are reproduced by all products. Nevertheless, large Q(sub le)and Q(sub h) absolute differences are also observed. The fluxes were spatially averaged for 10 vegetation classes. The larger Q(sub le) differences were observed for the rain forest but, when normalized by mean fluxes, the differences were comparable to other classes. In general, the correlations between Q(sub le) and R(sub n) were higher for the satellite-based products compared with the reanalyses and off-line models. The fluxes were also averaged for 10 selected basins. The seasonality was generally well captured by all products, but large differences in the flux partitioning were observed for some products and basins.

  6. IPRT polarized radiative transfer model intercomparison project - Three-dimensional test cases (phase B)

    NASA Astrophysics Data System (ADS)

    Emde, Claudia; Barlakas, Vasileios; Cornet, Céline; Evans, Frank; Wang, Zhen; Labonotte, Laurent C.; Macke, Andreas; Mayer, Bernhard; Wendisch, Manfred

    2018-04-01

    Initially unpolarized solar radiation becomes polarized by scattering in the Earth's atmosphere. In particular molecular scattering (Rayleigh scattering) polarizes electromagnetic radiation, but also scattering of radiation at aerosols, cloud droplets (Mie scattering) and ice crystals polarizes. Each atmospheric constituent produces a characteristic polarization signal, thus spectro-polarimetric measurements are frequently employed for remote sensing of aerosol and cloud properties. Retrieval algorithms require efficient radiative transfer models. Usually, these apply the plane-parallel approximation (PPA), assuming that the atmosphere consists of horizontally homogeneous layers. This allows to solve the vector radiative transfer equation (VRTE) efficiently. For remote sensing applications, the radiance is considered constant over the instantaneous field-of-view of the instrument and each sensor element is treated independently in plane-parallel approximation, neglecting horizontal radiation transport between adjacent pixels (Independent Pixel Approximation, IPA). In order to estimate the errors due to the IPA approximation, three-dimensional (3D) vector radiative transfer models are required. So far, only a few such models exist. Therefore, the International Polarized Radiative Transfer (IPRT) working group of the International Radiation Commission (IRC) has initiated a model intercomparison project in order to provide benchmark results for polarized radiative transfer. The group has already performed an intercomparison for one-dimensional (1D) multi-layer test cases [phase A, 1]. This paper presents the continuation of the intercomparison project (phase B) for 2D and 3D test cases: a step cloud, a cubic cloud, and a more realistic scenario including a 3D cloud field generated by a Large Eddy Simulation (LES) model and typical background aerosols. The commonly established benchmark results for 3D polarized radiative transfer are available at the IPRT website (http://www.meteo.physik.uni-muenchen.de/ iprt).

  7. Elemental composition of ambient aerosols measured with high temporal resolution using an online XRF spectrometer

    NASA Astrophysics Data System (ADS)

    Furger, Markus; Cruz Minguillón, María; Yadav, Varun; Slowik, Jay G.; Hüglin, Christoph; Fröhlich, Roman; Petterson, Krag; Baltensperger, Urs; Prévôt, André S. H.

    2017-06-01

    The Xact 625 Ambient Metals Monitor was tested during a 3-week field campaign at the rural, traffic-influenced site Härkingen in Switzerland during the summer of 2015. The field campaign encompassed the Swiss National Day fireworks event, providing increased concentrations and unique chemical signatures compared to non-fireworks (or background) periods. The objective was to evaluate the data quality by intercomparison with other independent measurements and test its applicability for aerosol source quantification. The Xact was configured to measure 24 elements in PM10 with 1 h time resolution. Data quality was evaluated for 10 24 h averages of Xact data by intercomparison with 24 h PM10 filter data analysed with ICP-OES for major elements, ICP-MS for trace elements, and gold amalgamation atomic absorption spectrometry for Hg. Ten elements (S, K, Ca, Ti, Mn, Fe, Cu, Zn, Ba, Pb) showed excellent correlation between the compared methods, with r2 values ≥ 0.95. However, the slopes of the regressions between Xact 625 and ICP data varied from 0.97 to 1.8 (average 1.28) and thus indicated generally higher Xact elemental concentrations than ICP for these elements. Possible reasons for these differences are discussed, but further investigations are needed. For the remaining elements no conclusions could be drawn about their quantification for various reasons, mainly detection limit issues. An indirect intercomparison of hourly values was performed for the fireworks peak, which brought good agreement of total masses when the Xact data were corrected with the regressions from the 24 h value intercomparison. The results demonstrate that multi-metal characterization at high-time-resolution capability of Xact is a valuable and practical tool for ambient monitoring.

  8. WCRP Task Team for the Intercomparison of Reanalyses (TIRA): Motivation and Progress

    NASA Technical Reports Server (NTRS)

    Bosilovich, Michael

    2017-01-01

    Reanalyses have proven to be an important resource for weather and climate related research, as well as societal applications at large. Several centers have emerged to produce new atmospheric reanalyses in various forms every few years. In addition, land and ocean communities are producing disciplinary uncoupled reanalyses. Current research and development in reanalysis is directed at (1) extending the length of reanalyzed period and (2) use of coupled Earth system models for climate reanalysis. While WCRPs involvement in the reanalyses communities through its Data Advisory Council (WDAC) has been substantial, for example in organizing international conferences on reanalyses, a central team of reanalyses expertise is not in place in the WCRP structure. The differences among reanalyses and their inherent uncertainties are some of the most important questions for both users and developers of reanalyses. Therefore, a collaborative effort to systematically assess and intercompare reanalyses would be a logical progression that fills the needs of the community and contributes to the WCRP mission. The primary charge to the TIRA is to develop a reanalysis intercomparison project plan that will attain the following objectives.1)To foster understanding and estimation of uncertainties in reanalysis data by intercomparison and other means 2)To communicate new developments and best practices among the reanalyses producing centers 3)To enhance the understanding of data and assimilation issues and their impact on uncertainties, leading to improved reanalyses for climate assessment 4)To communicate the strengths and weaknesses of reanalyses, their fitness for purpose, and best practices in the use of reanalysis datasets by the scientific community. This presentation outlines the need for a task team on reanalyses, their intercomparison, the objectives of the team and progress thus far.

  9. Health Aspects of a Nuclear or Radiological Attack

    DTIC Science & Technology

    2010-07-01

    treatment capabilities, population monitoring, decontamination, and so on. The requirements should be developed by a process that engages stakeholders...IND or reactor accident would release radioiodine that could result in hypothyroidism or late thyroid nodules or cancer. External contamination... Treatment and Long-Term Monitoring Victims of acute radiation-related events will require prompt diagnosis and treatment of emergency medical and

  10. Biogeochemical Considerations Related To The Remediation Of I-129 Plumes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaplan, D. I.; Yeager, C.; Denham, M. E.

    2012-09-24

    The objectives of this report were to: provide a current state of the science of radioiodine biogeochemistry relevant to its fate and transport at the Hanford Site; conduct a review of Hanford Site data dealing with groundwater {sup 129}I; and identify critical knowledge gaps necessary for successful selection, implementation, and technical defensibility in support of remediation decisions.

  11. Uterine uptake of iodine-123 metaiodobenzylguanidine during the menstrual phase of uterine cycle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bomanji, J.; Britton, K.E.

    Radioiodinated I-123 metaiodobenzylguanidine (MIBG) has been used for diagnostic purposes for detection of apudomas. In this paper normal physiological uptake of I-123 MIBG by the uterus during the menstrual phase of the uterine cycle is reported. It is likely that I-123 MIBG can be used to evaluate some of the problems in this context.

  12. EANM Dosimetry Committee series on standard operational procedures for pre-therapeutic dosimetry II. Dosimetry prior to radioiodine therapy of benign thyroid diseases.

    PubMed

    Hänscheid, Heribert; Canzi, Cristina; Eschner, Wolfgang; Flux, Glenn; Luster, Markus; Strigari, Lidia; Lassmann, Michael

    2013-07-01

    The EANM Dosimetry Committee Series "Standard Operational Procedures for Pre-Therapeutic Dosimetry" (SOP) provides advice to scientists and clinicians on how to perform patient-specific absorbed dose assessments. This particular SOP describes how to tailor the therapeutic activity to be administered for radioiodine therapy of benign thyroid diseases such as Graves' disease or hyperthyroidism. Pretherapeutic dosimetry is based on the assessment of the individual (131)I kinetics in the target tissue after the administration of a tracer activity. The present SOP makes proposals on the equipment to be used and guides the user through the measurements. Time schedules for the measurement of the fractional (131)I uptake in the diseased tissue are recommended and it is shown how to calculate from these datasets the therapeutic activity necessary to administer a predefined target dose in the subsequent therapy. Potential sources of error are pointed out and the inherent uncertainties of the procedures depending on the number of measurements are discussed. The theoretical background and the derivation of the listed equations from compartment models of the iodine kinetics are explained in a supplementary file published online only.

  13. Calibration/validation strategy for GOES-R L1b data products

    NASA Astrophysics Data System (ADS)

    Fulbright, Jon P.; Kline, Elizabeth; Pogorzala, David; MacKenzie, Wayne; Williams, Ryan; Mozer, Kathryn; Carter, Dawn; Race, Randall; Sims, Jamese; Seybold, Matthew

    2016-10-01

    The Geostationary Operational Environmental Satellite-R series (GOES-R) will be the next generation of NOAA geostationary environmental satellites. The first satellite in the series is planned for launch in November 2016. The satellite will carry six instruments dedicated to the study of the Earth's weather, lightning mapping, solar observations, and space weather monitoring. Each of the six instruments require specialized calibration plans to achieve their product quality requirements. In this talk we will describe the overall on-orbit calibration program and data product release schedule of the GOES-R program, as well as an overview of the strategies of the individual instrument science teams. The Advanced Baseline Imager (ABI) is the primary Earth-viewing weather imaging instrument on GOES-R. Compared to the present on-orbit GOES imagers, ABI will provide three times the spectral bands, four times the spatial resolution, and operate five times faster. The increased data demands and product requirements necessitate an aggressive and innovative calibration campaign. The Geostationary Lightning Mapper (GLM) will provide continuous rapid lightning detection information covering the Americas and nearby ocean regions. The frequency of lightning activity points to the intensification of storms and may improve tornado warning lead time. The calibration of GLM will involve intercomparisons with ground-based lightning detectors, an airborne field campaign, and a ground-based laser beacon campaign. GOES-R also carries four instruments dedicated to the study of the space environment. The Solar Ultraviolet Imager (SUVI) and the Extreme Ultraviolet and X-Ray Irradiance Sensors (EXIS) will study solar activity that may affect power grids, communication, and spaceflight. The Space Environment In-Situ Suite (SEISS) and the Magnetometer (MAG) study the in-situ space weather environment. These instruments follow a calibration and validation (cal/val) program that relies on intercomparisons with other space-based sensors and utilize special spacecraft maneuvers. Given the importance of cal/val to the success of GOES-R, the mission is committed to a long-term effort. This commitment enhances our knowledge of the long-term data quality and builds user confidence. The plan is a collaborative effort amongst the National Oceanic and Atmospheric Administration (NOAA), the National Institute of Standards and Technology (NIST), and the National Aeronautics and Space Administration (NASA). It is being developed based on the experience and lessons-learned from the heritage GOES and Polar-orbiting Operational Environmental Satellite (POES) systems, as well as other programs. The methodologies described in the plan encompass both traditional approaches and the current state-of-the-art in cal/val.

  14. The Vulnerability, Impacts, Adaptation and Climate Services Advisory Board (VIACS AB V1.0) Contribution to CMIP6

    NASA Technical Reports Server (NTRS)

    Ruane, Alex C.; Teichmann, Claas; Arnell, Nigel W.; Carter, Timothy R.; Ebi, Kristie L.; Frieler, Katja; Goodess, Clare M.; Hewitson, Bruce; Horton, Radley; Kovats, R. Sari; hide

    2016-01-01

    This paper describes the motivation for the creation of the Vulnerability, Impacts, Adaptation and Climate Services (VIACS) Advisory Board for the Sixth Phase of the Coupled Model Intercomparison Project (CMIP6), its initial activities, and its plans to serve as a bridge between climate change applications experts and climate modelers. The climate change application community comprises researchers and other specialists who use climate information (alongside socioeconomic and other environmental information) to analyze vulnerability, impacts, and adaptation of natural systems and society in relation to past, ongoing, and projected future climate change. Much of this activity is directed toward the co-development of information needed by decisionmakers for managing projected risks. CMIP6 provides a unique opportunity to facilitate a two-way dialog between climate modelers and VIACS experts who are looking to apply CMIP6 results for a wide array of research and climate services objectives. The VIACS Advisory Board convenes leaders of major impact sectors, international programs, and climate services to solicit community feedback that increases the applications relevance of the CMIP6-Endorsed Model Intercomparison Projects (MIPs). As an illustration of its potential, the VIACS community provided CMIP6 leadership with a list of prioritized climate model variables and MIP experiments of the greatest interest to the climate model applications community, indicating the applicability and societal relevance of climate model simulation outputs. The VIACS Advisory Board also recommended an impacts version of Obs4MIPs (observational datasets) and indicated user needs for the gridding and processing of model output.

  15. The Software Architecture of Global Climate Models

    NASA Astrophysics Data System (ADS)

    Alexander, K. A.; Easterbrook, S. M.

    2011-12-01

    It has become common to compare and contrast the output of multiple global climate models (GCMs), such as in the Climate Model Intercomparison Project Phase 5 (CMIP5). However, intercomparisons of the software architecture of GCMs are almost nonexistent. In this qualitative study of seven GCMs from Canada, the United States, and Europe, we attempt to fill this gap in research. We describe the various representations of the climate system as computer programs, and account for architectural differences between models. Most GCMs now practice component-based software engineering, where Earth system components (such as the atmosphere or land surface) are present as highly encapsulated sub-models. This architecture facilitates a mix-and-match approach to climate modelling that allows for convenient sharing of model components between institutions, but it also leads to difficulty when choosing where to draw the lines between systems that are not encapsulated in the real world, such as sea ice. We also examine different styles of couplers in GCMs, which manage interaction and data flow between components. Finally, we pay particular attention to the varying levels of complexity in GCMs, both between and within models. Many GCMs have some components that are significantly more complex than others, a phenomenon which can be explained by the respective institution's research goals as well as the origin of the model components. In conclusion, although some features of software architecture have been adopted by every GCM we examined, other features show a wide range of different design choices and strategies. These architectural differences may provide new insights into variability and spread between models.

  16. An inter-comparison of surface energy flux measurement systems used during FIFE, 1987

    NASA Technical Reports Server (NTRS)

    Nie, D.; Kanemasu, E. T.; Fritschen, L. J.; Weaver, H.; Smith, E. A.; Verma, S. B.; Field, R. T.; Kustas, W.; Stewart, J. B.

    1990-01-01

    During the first International Satellite Land Surface Climatology Program Field Experiment (FIFE-87), surface energy fluxes were measured at 22 flux sites by nine groups of scientists using different measuring systems. A rover Bowen ratio station was taken to nearly all the flux stations to serve as a reference for estimating the instrument related differences. The rover system was installed within a few meters from the host instrument of a site. Net radiation, Bowen ratio, and latent heat fluxes were compared between the rover and the host for the stations visited. Linear regression analysis was used to examine the relationship between rover measurements and host measurements. These inter-comparisons are needed to examine the influence of instrumentation on measurement uncertainty. Highly significant effects of instrument type were detected from these comparisons. Instruments of the same type showed average differences of less than 5 percent for net radiation, 10 percent for Bowen ratio, and 6 percent for latent heat flux. The corresponding average differences for different types of instruments can be up to 10, 30, and 20 percent respectively. The Didcot net radiometer gave higher net radiation while the Swissteco type showed lower values, as compared to the corrected REBS model. The 4-way components methed and the Thornswaite type give similar values to the REBS. The SERBS type Bowen ratio systems exhibit slightly lower Bowen ratios and thus higher latent heat fluxes, compared to the AZET systems. Eddy correlation systems showed slightly lower latent heat flux in comparison to the Bowen ratio systems.

  17. Quality assessment concept of the World Data Center for Climate and its application to CMIP5 data

    NASA Astrophysics Data System (ADS)

    Stockhause, M.; Höck, H.; Toussaint, F.; Lautenschlager, M.

    2012-08-01

    The preservation of data in a high state of quality which is suitable for interdisciplinary use is one of the most pressing and challenging current issues in long-term archiving. For high volume data such as climate model data, the data and data replica are no longer stored centrally but distributed over several local data repositories, e.g. the data of the Climate Model Intercomparison Project Phase 5 (CMIP5). The most important part of the data is to be archived, assigned a DOI, and published according to the World Data Center for Climate's (WDCC) application of the DataCite regulations. The integrated part of WDCC's data publication process, the data quality assessment, was adapted to the requirements of a federated data infrastructure. A concept of a distributed and federated quality assessment procedure was developed, in which the workload and responsibility for quality control is shared between the three primary CMIP5 data centers: Program for Climate Model Diagnosis and Intercomparison (PCMDI), British Atmospheric Data Centre (BADC), and WDCC. This distributed quality control concept, its pilot implementation for CMIP5, and first experiences are presented. The distributed quality control approach is capable of identifying data inconsistencies and to make quality results immediately available for data creators, data users and data infrastructure managers. Continuous publication of new data versions and slow data replication prevents the quality control from check completion. This together with ongoing developments of the data and metadata infrastructure requires adaptations in code and concept of the distributed quality control approach.

  18. The Vulnerability, Impacts, Adaptation and Climate Services Advisory Board (VIACS AB v1.0) contribution to CMIP6

    NASA Astrophysics Data System (ADS)

    Ruane, Alex C.; Teichmann, Claas; Arnell, Nigel W.; Carter, Timothy R.; Ebi, Kristie L.; Frieler, Katja; Goodess, Clare M.; Hewitson, Bruce; Horton, Radley; Sari Kovats, R.; Lotze, Heike K.; Mearns, Linda O.; Navarra, Antonio; Ojima, Dennis S.; Riahi, Keywan; Rosenzweig, Cynthia; Themessl, Matthias; Vincent, Katharine

    2016-09-01

    This paper describes the motivation for the creation of the Vulnerability, Impacts, Adaptation and Climate Services (VIACS) Advisory Board for the Sixth Phase of the Coupled Model Intercomparison Project (CMIP6), its initial activities, and its plans to serve as a bridge between climate change applications experts and climate modelers. The climate change application community comprises researchers and other specialists who use climate information (alongside socioeconomic and other environmental information) to analyze vulnerability, impacts, and adaptation of natural systems and society in relation to past, ongoing, and projected future climate change. Much of this activity is directed toward the co-development of information needed by decision-makers for managing projected risks. CMIP6 provides a unique opportunity to facilitate a two-way dialog between climate modelers and VIACS experts who are looking to apply CMIP6 results for a wide array of research and climate services objectives. The VIACS Advisory Board convenes leaders of major impact sectors, international programs, and climate services to solicit community feedback that increases the applications relevance of the CMIP6-Endorsed Model Intercomparison Projects (MIPs). As an illustration of its potential, the VIACS community provided CMIP6 leadership with a list of prioritized climate model variables and MIP experiments of the greatest interest to the climate model applications community, indicating the applicability and societal relevance of climate model simulation outputs. The VIACS Advisory Board also recommended an impacts version of Obs4MIPs and indicated user needs for the gridding and processing of model output.

  19. The Latest SORCE Solar Spectral Irradiance Data Release: Inter-Comparison and a First Look at TSIS SIM Measurement.

    NASA Astrophysics Data System (ADS)

    Beland, S.; Sandoval, L.; Vanier, B.; Elliott, J.; Harder, J. W.; Snow, M. A.; Woods, T. N.; Richard, E. C.; Pilewskie, P.

    2017-12-01

    The Spectral Irradiance Monitor (SIM), the SOLar STellar Irradiance Comparison Experiment (SOLSTICE), and the XUV Photometer System (XPS) instruments on board the Solar Radiation and Climate Experiment (SORCE) mission have been taking daily Solar spectral irradiance (SSI) measurements since April 2003. We present the latest data releases from these instruments, describing the improvements in the new datasets and the trends measured during Solar cycles 23 and 24. An inter-comparison of the SSI over the overlapping wavelengths for SIM and SOLSTICE is presented as well as, if the data is available, a comparison with the first light measurements from TSIS-SIM.

  20. Ozone Response to Aircraft Emissions: Sensitivity Studies with Two-dimensional Models

    NASA Technical Reports Server (NTRS)

    Ko, Malcolm K. W.; Weisenstein, Debra; Jackman, Charles H.; Douglass, Anne R.; Bureske, K.; Weubbles, Donald J.; Kinnison, Douglas E.; Brasseur, G.; Pyle, J.; Jones, Anna

    1992-01-01

    Our first intercomparison/assessment of the effects of a proposed high-speed civil transport (HSCT) fleet on the stratosphere is presented. These model calculations should be considered more as sensitivity studies, primarily designed to serve the following purposes: (1) to allow for intercomparison of model predictions; (2) to focus on the range of fleet operations and engine specifications giving minimal environmental impact; and (3) to provide the basis for future assessment studies. The basic scenarios were chosen to be as realistic as possible, using the information available on anticipated developments in technology. They are not to be interpreted as a commitment or goal for environmental acceptability.

  1. NASA Giovanni Portals for NLDAS/GLDAS Online Visualization, Analysis, and Intercomparison

    NASA Technical Reports Server (NTRS)

    Rui, Hualan; Teng, William L.; Vollmer, Bruce; Mocko, David M.; Beaudoing, Hiroko Kato; Rodell, Matthew

    2011-01-01

    The North American Land Data Assimilation System (NLDAS) and Global Land Data Assimilation System (GLDAS) are generating a series of land surface forcing (e.g., precipitation, surface meteorology, and radiation), state (e.g., soil moisture and temperature, and snow), and flux (e.g., evaporation and sensible heat flux) products, simulated by several land surface models. To date, NLDAS and GLDAS have generated more than 30 (1979 - present) and 60 (1948 - present) years of data, respectively. To further facilitate data accessibility and utilization, three new portals in the NASA Giovanni system have been made available for NLDAS and GLDAS online visualization, analysis, and intercomparison.

  2. Ozone profile intercomparison based on simultaneous observations between 20 and 40 km

    NASA Technical Reports Server (NTRS)

    Aimedieu, P.; Krueger, A. J.; Robbins, D. E.; Simon, P. C.

    1983-01-01

    The vertical distribution of stratospheric ozone has been simultaneously measured by means of five different instruments carried on the same balloon payload. The launches were performed from Gap during the intercomparison campaign conducted in June 1981 in southern France. Data obtained between altitudes of 20 and 40 km are compared and discussed. Vertical profiles deduced from Electrochemical Concentration Cell sondes launched from the same location by small balloons and from short Umkehr measurements made at Mt Chiran (France) are also included in this comparison. Systematic differences of the order of 20 percent between ozone profiles deduced from solar u.v. absorption and in situ techniques are found.

  3. Impact of Spatial Scales on the Intercomparison of Climate Scenarios

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Wei; Steptoe, Michael; Chang, Zheng

    2017-01-01

    Scenario analysis has been widely applied in climate science to understand the impact of climate change on the future human environment, but intercomparison and similarity analysis of different climate scenarios based on multiple simulation runs remain challenging. Although spatial heterogeneity plays a key role in modeling climate and human systems, little research has been performed to understand the impact of spatial variations and scales on similarity analysis of climate scenarios. To address this issue, the authors developed a geovisual analytics framework that lets users perform similarity analysis of climate scenarios from the Global Change Assessment Model (GCAM) using a hierarchicalmore » clustering approach.« less

  4. Past and future weather-induced risk in crop production

    NASA Astrophysics Data System (ADS)

    Elliott, J. W.; Glotter, M.; Russo, T. A.; Sahoo, S.; Foster, I.; Benton, T.; Mueller, C.

    2016-12-01

    Drought-induced agricultural loss is one of the most costly impacts of extreme weather and may harm more people than any other consequence of climate change. Improvements in farming practices have dramatically increased crop productivity, but yields today are still tightly linked to climate variation. We report here on a number of recent studies evaluating extreme event risk and impacts under historical and near future conditions, including studies conducted as part of the Agricultural Modeling Intercomparison and Improvement Project (AgMIP), the Inter-Sectoral Impacts Model Intercomparison Project (ISI-MIP) and the UK-US Taskforce on Extreme Weather and Global Food System Resilience.

  5. The Agricultural Model Intercomparison and Improvement Project: Phase I Activities by a Global Community of Science. Chapter 1

    NASA Technical Reports Server (NTRS)

    Rosenzweig, Cynthia E.; Jones, James W.; Hatfield, Jerry L.; Antle, John M.; Ruane, Alexander C.; Mutter, Carolyn Z.

    2015-01-01

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) was founded in 2010. Its mission is to improve substantially the characterization of world food security as affected by climate variability and change, and to enhance adaptation capacity in both developing and developed countries. The objectives of AgMIP are to: Incorporate state-of-the-art climate, crop/livestock, and agricultural economic model improvements into coordinated multi-model regional and global assessments of future climate impacts and adaptation and other key aspects of the food system. Utilize multiple models, scenarios, locations, crops/livestock, and participants to explore uncertainty and the impact of data and methodological choices. Collaborate with regional experts in agronomy, animal sciences, economics, and climate to build a strong basis for model applications, addressing key climate related questions and sustainable intensification farming systems. Improve scientific and adaptive capacity in modeling for major agricultural regions in the developing and developed world, with a focus on vulnerable regions. Improve agricultural data and enhance data-sharing based on their intercomparison and evaluation using best scientific practices. Develop modeling frameworks to identify and evaluate promising adaptation technologies and policies and to prioritize strategies.

  6. Constraints and potentials of future irrigation water availability on agricultural production under climate change.

    PubMed

    Elliott, Joshua; Deryng, Delphine; Müller, Christoph; Frieler, Katja; Konzmann, Markus; Gerten, Dieter; Glotter, Michael; Flörke, Martina; Wada, Yoshihide; Best, Neil; Eisner, Stephanie; Fekete, Balázs M; Folberth, Christian; Foster, Ian; Gosling, Simon N; Haddeland, Ingjerd; Khabarov, Nikolay; Ludwig, Fulco; Masaki, Yoshimitsu; Olin, Stefan; Rosenzweig, Cynthia; Ruane, Alex C; Satoh, Yusuke; Schmid, Erwin; Stacke, Tobias; Tang, Qiuhong; Wisser, Dominik

    2014-03-04

    We compare ensembles of water supply and demand projections from 10 global hydrological models and six global gridded crop models. These are produced as part of the Inter-Sectoral Impacts Model Intercomparison Project, with coordination from the Agricultural Model Intercomparison and Improvement Project, and driven by outputs of general circulation models run under representative concentration pathway 8.5 as part of the Fifth Coupled Model Intercomparison Project. Models project that direct climate impacts to maize, soybean, wheat, and rice involve losses of 400-1,400 Pcal (8-24% of present-day total) when CO2 fertilization effects are accounted for or 1,400-2,600 Pcal (24-43%) otherwise. Freshwater limitations in some irrigated regions (western United States; China; and West, South, and Central Asia) could necessitate the reversion of 20-60 Mha of cropland from irrigated to rainfed management by end-of-century, and a further loss of 600-2,900 Pcal of food production. In other regions (northern/eastern United States, parts of South America, much of Europe, and South East Asia) surplus water supply could in principle support a net increase in irrigation, although substantial investments in irrigation infrastructure would be required.

  7. Airborne intercomparison of nitric oxide measurement techniques

    NASA Technical Reports Server (NTRS)

    Hoell, James M., Jr.; Gregory, Gerald L.; Mcdougal, David S.; Torres, Arnold L.; Davis, Douglas D.

    1987-01-01

    Results from an airborne intercomparison of techniques to measure tropospheric levels of nitric oxide (NO) are discussed. The intercomparison was part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and was conducted during missions flown in the fall of 1983 and spring of 1984. Instruments intercompared included a laser-induced fluorescence (LIF) system and two chemiluminescence instruments (CL). NO mixing ratios from below 5 pptv (parts per trillion by volume) to greater than 100 pptv were reported, with the majority less than 20 pptv. Good correlation was observed between the measurements reported by the CL and LIF techniques. The general level of agreement observed for the ensemble of measurements obtained during the two missions provides the basis from which one can conclude that equally 'valid' measurements of background levels of NO can be expected from either CL or LIF instruments. At the same time the periods of disagreement that were observed between the CL and LIF instruments as well as between the two CL instruments highlight the difficulty of obtaining reliable measurements with NO mixing ratios in the 5-20 pptv range and emphasize the vigilance that should be maintained in future NO measurements.

  8. Nuclear accident dosimetry intercomparison studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sims, C.S.

    1989-09-01

    Twenty-two nuclear accident dosimetry intercomparison studies utilizing the fast-pulse Health Physics Research Reactor at the Oak Ridge National Laboratory have been conducted since 1965. These studies have provided a total of 62 different organizations a forum for discussion of criticality accident dosimetry, an opportunity to test their neutron and gamma-ray dosimetry systems under a variety of simulated criticality accident conditions, and the experience of comparing results with reference dose values as well as with the measured results obtained by others making measurements under identical conditions. Sixty-nine nuclear accidents (27 with unmoderated neutron energy spectra and 42 with eight different shieldedmore » spectra) have been simulated in the studies. Neutron doses were in the 0.2-8.5 Gy range and gamma doses in the 0.1-2.0 Gy range. A total of 2,289 dose measurements (1,311 neutron, 978 gamma) were made during the intercomparisons. The primary methods of neutron dosimetry were activation foils, thermoluminescent dosimeters, and blood sodium activation. The main methods of gamma dose measurement were thermoluminescent dosimeters, radiophotoluminescent glass, and film. About 68% of the neutron measurements met the accuracy guidelines (+/- 25%) and about 52% of the gamma measurements met the accuracy criterion (+/- 20%) for accident dosimetry.« less

  9. Economic impacts of climate change on agriculture: the AgMIP approach

    NASA Astrophysics Data System (ADS)

    Delincé, Jacques; Ciaian, Pavel; Witzke, Heinz-Peter

    2015-01-01

    The current paper investigates the long-term global impacts on crop productivity under different climate scenarios using the AgMIP approach (Agricultural Model Intercomparison and Improvement Project). The paper provides horizontal model intercomparison from 11 economic models as well as a more detailed analysis of the simulated effects from the Common Agricultural Policy Regionalized Impact (CAPRI) model to systematically compare its performance with other AgMIP models and specifically for the Chinese agriculture. CAPRI is a comparative static partial equilibrium model extensively used for medium and long-term economic and environmental policy impact applications. The results indicate that, at the global level, the climate change will cause an agricultural productivity decrease (between -2% and -15% by 2050), a food price increase (between 1.3% and 56%) and an expansion of cultivated area (between 1% and 4%) by 2050. The results for China indicate that the climate change effects tend to be smaller than the global impacts. The CAPRI-simulated effects are, in general, close to the median across all AgMIP models. Model intercomparison analyses reveal consistency in terms of direction of change to climate change but relatively strong heterogeneity in the magnitude of the effects between models.

  10. Long History of IAM Comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Steven J.; Clarke, Leon E.; Edmonds, James A.

    2015-04-23

    Correspondence to editor: We agree with the editors that the assumptions behind models of all types, including integrated assessment models (IAMs), should be as transparent as possible. The editors were in error, however, when they implied that the IAM community is just “now emulating the efforts of climate researchers by instigating their own model inter-comparison projects (MIPs).” In fact, model comparisons for integrated assessment and climate models followed a remarkably similar trajectory. Early General Circulation Model (GCM) comparison efforts, evolved to the first Atmospheric Model Inter-comparison Project (AMIP), which was initiated in the early 1990s. Atmospheric models evolved to coupledmore » atmosphere-ocean models (AOGCMs) and results from the first Coupled Model Inter-Comparison Project (CMIP1) become available about a decade later. Results of first energy model comparison exercise, conducted under the auspices of the Stanford Energy Modeling Forum, were published in 1977. A summary of the first comparison focused on climate change was published in 1993. As energy models were coupled to simple economic and climate models to form IAMs, the first comparison exercise for IAMs (EMF-14) was initiated in 1994, and IAM comparison exercises have been on-going since this time.« less

  11. The Geoengineering Model Intercomparison Project Phase 6 (GeoMIP6): Simulation design and preliminary results

    DOE PAGES

    Kravitz, Benjamin S.; Robock, Alan; Tilmes, S.; ...

    2015-10-27

    We present a suite of new climate model experiment designs for the Geoengineering Model Intercomparison Project (GeoMIP). This set of experiments, named GeoMIP6 (to be consistent with the Coupled Model Intercomparison Project Phase 6), builds on the previous GeoMIP project simulations, and has been expanded to address several further important topics, including key uncertainties in extreme events, the use of geoengineering as part of a portfolio of responses to climate change, and the relatively new idea of cirrus cloud thinning to allow more long wave radiation to escape to space. We discuss experiment designs, as well as the rationale formore » those designs, showing preliminary results from individual models when available. We also introduce a new feature, called the GeoMIP Testbed, which provides a platform for simulations that will be performed with a few models and subsequently assessed to determine whether the proposed experiment designs will be adopted as core (Tier 1) GeoMIP experiments. In conclusion, this is meant to encourage various stakeholders to propose new targeted experiments that address their key open science questions, with the goal of making GeoMIP more relevant to a broader set of communities.« less

  12. Models and Measurements Intercomparison 2

    NASA Technical Reports Server (NTRS)

    Park, Jae H. (Editor); Ko, Malcolm K. W. (Editor); Jackman, Charles H. (Editor); Plumb, R. Alan (Editor); Kaye, Jack A. (Editor); Sage, Karen H. (Editor)

    1999-01-01

    Models and Measurement Intercomparison II (MM II) summarizes the intercomparison of results from model simulations and observations of stratospheric species. Representatives from twenty-three modeling groups using twenty-nine models participated in these MM II exercises between 1996 and 1999. Twelve of the models were two- dimensional zonal-mean models while seventeen were three-dimensional models. This was an international effort as seven were from outside the United States. Six transport experiments and five chemistry experiments were designed for various models. Models participating in the transport experiments performed simulations of chemically inert tracers providing diagnostics for transport. The chemistry experiments involved simulating the distributions of chemically active trace cases including ozone. The model run conditions for dynamics and chemistry were prescribed in order to minimize the factors that caused differences in the models. The report includes a critical review of the results by the participants and a discussion of the causes of differences between modeled and measured results as well as between results from different models, A sizable effort went into preparation of the database of the observations. This included a new climatology for ozone. The report should help in evaluating the results from various predictive models for assessing humankind perturbations of the stratosphere.

  13. Criticality accident dosimetry systems: an international intercomparison at the SILENE reactor in 2002.

    PubMed

    Médioni, R; Asselineau, B; Verrey, B; Trompier, F; Itié, C; Texier, C; Muller, H; Pelcot, G; Clairand, I; Jacquet, X; Pochat, J L

    2004-01-01

    In criticality accident dosimetry and more generally for high dose measurements, special techniques are used to measure separately the gamma ray and neutron components of the dose. To improve these techniques and to check their dosimetry systems (physical and/or biological), a total of 60 laboratories from 29 countries (America, Europe, Asia) participated in an international intercomparaison, which took place in France from 9 to 21 June 2002, at the SILENE reactor in Valduc and at a pure gamma source in Fontenay-aux-Roses. This intercomparison was jointly organised by the IRSN and the CEA with the help of the NEA/OCDE and was partly supported by the European Communities. This paper describes the aim of this intercomparison, the techniques used by the participants and the two radiation sources and their characteristics. The experimental arrangements of the dosemeters for the irradiations in free air or on phantoms are given. Then the dosimetric quantities measured and reported by the participants are summarised, analysed and compared with the reference values. The present paper concerns only the physical dosimetry and essentially experiments performed on the SILENE facility. The results obtained with the biological dosimetry are published in two other papers of this issue.

  14. Metafitting: Weight optimization for least-squares fitting of PTTI data

    NASA Technical Reports Server (NTRS)

    Douglas, Rob J.; Boulanger, J.-S.

    1995-01-01

    For precise time intercomparisons between a master frequency standard and a slave time scale, we have found it useful to quantitatively compare different fitting strategies by examining the standard uncertainty in time or average frequency. It is particularly useful when designing procedures which use intermittent intercomparisons, with some parameterized fit used to interpolate or extrapolate from the calibrating intercomparisons. We use the term 'metafitting' for the choices that are made before a fitting procedure is operationally adopted. We present methods for calculating the standard uncertainty for general, weighted least-squares fits and a method for optimizing these weights for a general noise model suitable for many PTTI applications. We present the results of the metafitting of procedures for the use of a regular schedule of (hypothetical) high-accuracy frequency calibration of a maser time scale. We have identified a cumulative series of improvements that give a significant reduction of the expected standard uncertainty, compared to the simplest procedure of resetting the maser synthesizer after each calibration. The metafitting improvements presented include the optimum choice of weights for the calibration runs, optimized over a period of a week or 10 days.

  15. The DeepMIP Contribution to PMIP4: Experimental Design for Model Simulations of the EECO, PETM, and pre-PETM (version 1.0)

    NASA Technical Reports Server (NTRS)

    Lunt, Daniel J.; Huber, Matthew; Anagnostou, Eleni; Baatsen, Michiel L. J.; Caballero, Rodrigo; DeConto, Rob; Dijkstra, Henk A.; Donnadieu, Yannick; Evans, David; Feng, Ran; hide

    2017-01-01

    Past warm periods provide an opportunity to evaluate climate models under extreme forcing scenarios, in particular high ( greater than 800 ppmv) atmospheric CO2 concentrations. Although a post hoc intercomparison of Eocene (approximately 50 Ma) climate model simulations and geological data has been carried out previously, models of past high-CO2 periods have never been evaluated in a consistent framework. Here, we present an experimental design for climate model simulations of three warm periods within the early Eocene and the latest Paleocene (the EECO, PETM, and pre-PETM). Together with the CMIP6 pre-industrial control and abrupt 4(times) CO2 simulations, and additional sensitivity studies, these form the first phase of DeepMIP - the Deep-time Model Intercomparison Project, itself a group within the wider Paleoclimate Modeling Intercomparison Project (PMIP). The experimental design specifies and provides guidance on boundary conditions associated with palaeogeography, greenhouse gases, astronomical configuration, solar constant, land surface processes, and aerosols. Initial conditions, simulation length, and output variables are also specified. Finally, we explain how the geological data sets, which will be used to evaluate the simulations, will be developed.

  16. The T-REX valley wind intercomparison project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidli, J; Billings, B J; Burton, R

    2008-08-07

    An accurate simulation of the evolution of the atmospheric boundary layer is very important, as the evolution of the boundary layer sets the stage for many weather phenomena, such as deep convection. Over mountain areas the evolution of the boundary layer is particularly complex, due to the nonlinear interaction between boundary layer turbulence and thermally-induced mesoscale wind systems, such as the slope and valley winds. As the horizontal resolution of operational forecasts progresses to finer and finer resolution, more and more of the thermally-induced mesoscale wind systems can be explicitly resolved, and it is very timely to document the currentmore » state-of-the-art of mesoscale models at simulating the coupled evolution of the mountain boundary layer and the valley wind system. In this paper we present an intercomparison of valley wind simulations for an idealized valley-plain configuration using eight state-of-the-art mesoscale models with a grid spacing of 1 km. Different sets of three-dimensional simulations are used to explore the effects of varying model dynamical cores and physical parameterizations. This intercomparison project was conducted as part of the Terrain-induced Rotor Experiment (T-REX; Grubisic et al., 2008).« less

  17. Intercomparison of different operational oceanographic forecast products in the CMEMS IBI area

    NASA Astrophysics Data System (ADS)

    Lorente, Pablo; Sotillo, Marcos G.; Dabrowski, Tomasz; Amo-Baladrón, Arancha; Aznar, Roland; De Pascual, Alvaro; Levier, Bruno; Bowyer, Peter; Cossarini, Gianpiero; Salon, Stefano; Tonani, Marina; Alvarez-Fanjul, Enrique

    2017-04-01

    The development of skill assessment software packages and dedicated web applications is a relatively novel theme in operational oceanography. Within the CMEMS IBI-MFC, the quality of IBI (Iberia-Biscay-Ireland) forecast products is assessed by means of NARVAL (North Atlantic Regional VALidation) web-based tool. The validation of IBI against independent in situ and remote-sensing measurements is routinely conducted to evaluate model's veracity and prognostic capabilities. Noticeable efforts are in progress to define meaningful skill scores and statistical metrics to quantitatively assess the quality and reliability of the IBI model solution. Likewise, the IBI-MFC compares the IBI forecast products with other model solutions by setting up specific intercomparison exercises on overlapping areas at diverse timescales. In this context, NARVAL web tool already includes a specific module to evaluate strengths and weaknesses of IBI versus other CMEMS operational ocean forecasting systems (OOFSs). In particular, the IBI physical ocean solution is compared against the CMEMS MED and NWS OOFSs. These CMEMS regional services delivered for the Mediterranean and the North West Shelves include data assimilation schemes in their respective operational chains and generate analogous ocean forecast products to the IBI ones. A number of physical parameters (i.e. sea surface temperature, salinity and current velocities) are evaluated through NARVAL on a daily basis in the overlapping areas existing between these three regional systems. NARVAL is currently being updated in order to extend this intercomparison of ocean model parameters to the biogeochemical solutions provided by the aforementioned OOFSs. More specifically, the simulated chlorophyll concentration is evaluated over several subregions of particular concern by using as benchmark the CMEMS satellite-derived observational products. In addition to this IBI comparison against other regional CMEMS products on overlapping areas, a specific intercomparison between the CMEMS GLOBAL solution and the IBI (regional application dynamically embedded in the former) is conducted in order to check its consistency and ability to outperform the parent model solution. Particular emphasis is placed on the comparison of time-series at specified locations (class-2 metrics). The standardized validation methodology presented here is particularly useful and could encompass the intercomparison of the regional application (IBI) and other nested higher resolution models at coastal/shelf scales to quantify the added value of downscaling in local downstream approaches.

  18. A protocol for the intercomparison of marine fishery and ecosystem models: Fish-MIP v1.0

    NASA Astrophysics Data System (ADS)

    Tittensor, Derek P.; Eddy, Tyler D.; Lotze, Heike K.; Galbraith, Eric D.; Cheung, William; Barange, Manuel; Blanchard, Julia L.; Bopp, Laurent; Bryndum-Buchholz, Andrea; Büchner, Matthias; Bulman, Catherine; Carozza, David A.; Christensen, Villy; Coll, Marta; Dunne, John P.; Fernandes, Jose A.; Fulton, Elizabeth A.; Hobday, Alistair J.; Huber, Veronika; Jennings, Simon; Jones, Miranda; Lehodey, Patrick; Link, Jason S.; Mackinson, Steve; Maury, Olivier; Niiranen, Susa; Oliveros-Ramos, Ricardo; Roy, Tilla; Schewe, Jacob; Shin, Yunne-Jai; Silva, Tiago; Stock, Charles A.; Steenbeek, Jeroen; Underwood, Philip J.; Volkholz, Jan; Watson, James R.; Walker, Nicola D.

    2018-04-01

    Model intercomparison studies in the climate and Earth sciences communities have been crucial to building credibility and coherence for future projections. They have quantified variability among models, spurred model development, contrasted within- and among-model uncertainty, assessed model fits to historical data, and provided ensemble projections of future change under specified scenarios. Given the speed and magnitude of anthropogenic change in the marine environment and the consequent effects on food security, biodiversity, marine industries, and society, the time is ripe for similar comparisons among models of fisheries and marine ecosystems. Here, we describe the Fisheries and Marine Ecosystem Model Intercomparison Project protocol version 1.0 (Fish-MIP v1.0), part of the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP), which is a cross-sectoral network of climate impact modellers. Given the complexity of the marine ecosystem, this class of models has substantial heterogeneity of purpose, scope, theoretical underpinning, processes considered, parameterizations, resolution (grain size), and spatial extent. This heterogeneity reflects the lack of a unified understanding of the marine ecosystem and implies that the assemblage of all models is more likely to include a greater number of relevant processes than any single model. The current Fish-MIP protocol is designed to allow these heterogeneous models to be forced with common Earth System Model (ESM) Coupled Model Intercomparison Project Phase 5 (CMIP5) outputs under prescribed scenarios for historic (from the 1950s) and future (to 2100) time periods; it will be adapted to CMIP phase 6 (CMIP6) in future iterations. It also describes a standardized set of outputs for each participating Fish-MIP model to produce. This enables the broad characterization of differences between and uncertainties within models and projections when assessing climate and fisheries impacts on marine ecosystems and the services they provide. The systematic generation, collation, and comparison of results from Fish-MIP will inform an understanding of the range of plausible changes in marine ecosystems and improve our capacity to define and convey the strengths and weaknesses of model-based advice on future states of marine ecosystems and fisheries. Ultimately, Fish-MIP represents a step towards bringing together the marine ecosystem modelling community to produce consistent ensemble medium- and long-term projections of marine ecosystems.

  19. Separation of iodine from mercury containing scrubbing solutions

    DOEpatents

    Burger, Leland L.; Scheele, Randall D.

    1979-01-01

    Radioactive iodines can be recovered from a nitric acid scrub solution containing mercuric nitrate by passing a current through the scrub solution to react the iodine with the mercuric nitrate to form mercuric iodate which precipitates out. The mercuric iodate can then be reacted to recover the radioiodine for further processing into a form suitable for long-term storage and to recover the mercury for recycling.

  20. A one-pot radioiodination of aryl amines via stable diazonium salts: preparation of 125I-imaging agents.

    PubMed

    Sloan, Nikki L; Luthra, Sajinder K; McRobbie, Graeme; Pimlott, Sally L; Sutherland, Andrew

    2017-10-05

    An operationally simple, one-pot, two-step tandem procedure that allows the incorporation of radioactive iodine into aryl amines via stable diazonium salts is described. The mild conditions are tolerant of various functional groups and substitution patterns, allowing late-stage, rapid access to a wide range of 125 I-labelled aryl compounds and SPECT radiotracers.

  1. An architecture for consolidating multidimensional time-series data onto a common coordinate grid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shippert, Tim; Gaustad, Krista

    Consolidating measurement data for use by data models or in inter-comparison studies frequently requires transforming the data onto a common grid. Standard methods for interpolating multidimensional data are often not appropriate for data with non-homogenous dimensionality, and are hard to implement in a consistent manner for different datastreams. These challenges are increased when dealing with the automated procedures necessary for use with continuous, operational datastreams. In this paper we introduce a method of applying a series of one-dimensional transformations to merge data onto a common grid, examine the challenges of ensuring consistent application of data consolidation methods, present a frameworkmore » for addressing those challenges, and describe the implementation of such a framework for the Atmospheric Radiation Measurement (ARM) program.« less

  2. An intercomparison of results from ferrous sulphate and photolytic converter techniques for measurements of NO(x) made during the NASA GTE/CITE 1 aircraft program

    NASA Technical Reports Server (NTRS)

    Ridley, B. A.; Carroll, M. A.; Torres, A. L.; Condon, E. P.; Sachse, G. W.; Hill, G. F.; Gregory, G. L.

    1988-01-01

    Two techniques designed for measurements of NO(x (NO + NO2) were intercompared during aircraft flights made in the spring of 1984 in the middle free troposphere over the eastern Pacific Ocean and southwestern U.S. One NO chemiluminescence instrument was equipped with a ferrous sulphate converter, another with a photolytic converter. The ferrous sulphate-equipped instrument was apparently much less specific for NO2. It registered levels about three times larger than the photolytic converter and gave NO2/NO ratios that were much larger than photochemical calculations would indicate as reasonable. Additionally, the results imply that active NO(x) was only 10-20 percent of the total odd nitrogen in the middle free troposphere.

  3. The Multispectral Atmospheric Mapping Sensor (MAMS): Instrument description, calibration and data quality

    NASA Technical Reports Server (NTRS)

    Jedlovec, G. J.; Menzel, W. P.; Atkinson, R.; Wilson, G. S.; Arvesen, J.

    1986-01-01

    A new instrument has been developed to produce high resolution imagery in eight visible and three infared spectral bands from an aircraft platform. An analysis of the data and calibration procedures has shown that useful data can be obtained at up to 50 m resolution with a 2.5 milliradian aperture. Single sample standard errors for the measurements are 0.5, 0.2, and 0.9 K for the 6.5, 11.1, and 12.3 micron spectral bands, respectively. These errors are halved when a 5.0 milliradian aperture is used to obtain 100 m resolution data. Intercomparisons with VAS and AVHRR measurements show good relative calibration. MAMS development is part of a larger program to develop multispectral Earth imaging capabilities from space platforms during the 1990s.

  4. Airborne Lidar measurements of aerosols, mixed layer heights, and ozone during the 1980 PEPE/NEROS summer field experiment

    NASA Technical Reports Server (NTRS)

    Browell, E. V.; Shipley, S. T.; Butler, C. F.; Ismail, S.

    1985-01-01

    A detailed summary of the NASA Ultraviolet Differential Absorption Lidar (UV DIAL) data archive obtained during the EPA Persistent Elevated Pollution Episode/Northeast Regional Oxidant Study (PEPE/NEROS) Summer Field Experiment Program (July through August 1980) is presented. The UV dial data set consists of remote measurements of mixed layer heights, aerosol backscatter cross sections, and sequential ozone profiles taken during 14 long-range flights onboard the NASA Wallops Flight Center Electra aircraft. These data are presented in graphic and tabular form, and they have been submitted to the PEPE/NEROS data archive on digital magnetic tape. The derivation of mixing heights and ozone profiles from UV Dial signals is discussed, and detailed intercomparisons with measurements obtained by in situ sensors are presented.

  5. Potential third-party radiation exposure from outpatients treated with {sup 131}I for hyperthyroidism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matheoud, Roberta; Reschini, Eugenio; Canzi, Cristina

    2004-12-01

    Thirty-three hyperthyroid patients treated with radioiodine (mean administered activity 414 MBq, range 163-555) were studied to determine if pretreatment dosimetry could be used to give radiation protection advice that could assure compliance with the effective dose constraints suggested by the European Commission. Effective doses to travelers, co-workers, and sleeping partners were estimated by integrating the effective dose rate-versus-time curve obtained by fitting the dose rates measured several times after radioiodine administration to a biexponential function. The mean estimated effective doses to travelers, co-workers, and sleeping partners were 0.11 mSv (0.05-0.24), 0.24 mSv (0.07-0.52), and 1.8 mSv (0.6-4.1), respectively. The bestmore » correlation was found between effective dose (D) in mSv and maximum activity (AU{sub max}) in MBq taken up in the thyroid: D{sub traveler}=0.0005*(AU{sub max})+0.04 (r=0.88,p<0.01); D{sub co-worker}=0.0013*(AU{sub max})+0.03(r=0.89,p<0.01); D{sub sleepingpartners}=0.0105*(AU{sub max})+0.16 (r=0.93,p<0.01). Private/public transports are always allowed. For the co-workers the effective dose constraint of 0.3 mSv is met without restrictions and with 3 days off work if AU{sub max} is lower or higher than 185 MBq, respectively. For the sleeping partners the effective dose constraint of 3 mSv is met without restriction and with 4 nights separate sleeping arrangements if AU{sub max} is lower or higher than 185 MBq, respectively. The potential for contamination by the patients was determined from perspiration samples taken from the patient's hands, forehead, and neck and in saliva at 4, 24, and 48 h after radioiodine treatment. The mean highest {sup 131}I activity levels for hands, forehead, neck, and saliva were 4.1 Bq/cm{sup 2}, 1.9 Bq/cm{sup 2}, 0.9 Bq/cm{sup 2}, and 796 kBq/g, respectively. The results indicate that there is minimal risk of contamination from these patients.« less

  6. TREATMENT OF SUBCLINICAL HYPERTHYROIDISM: EFFECT ON BODY COMPOSITION.

    PubMed

    Boj-Carceller, Diana; Sanz-París, Alejandro; Sánchez-Oriz, Enrique; García-Foncillas López, Rafael; Calmarza-Calmarza, Pilar; Blay-Cortes, Vicente; Abós-Olivares, Ma Dolores

    2015-11-01

    subclinical hyperthyroidism (SHT) is associated with harmful effects on cardiovascular system, bone metabolism and progression to clinical hyperthyroidism. Loss of weight is a common fact in patients with clinical hyperthyroidism and of particular relevance in elderly patients. to assess changes in body composition after radioiodine therapy for SHT due to toxic nodular goiter. prospective controlled cohort study. Patients with persistent SHT due to toxic nodular goiter were purposed to receive treatment with radioiodine (treatment group) or to delay treatment until the study was over (control group). All treated patients received 555 MBq of ¹³¹I. Body composition (lean mass, fat mass and bone mineral content) was determined by dual-energy X-ray absorptiometry (DEXA) at baseline and 12 months after. twenty-nine patients were studied (age 69.5 ± 11.5; 75.9% women; BMI 27.1 ± 5.7 kg/m²; serum thyrotropin (TSH) 0.20 ± 0.21 μUI/mL; serum free thyroxine (T4) 1.01 ± 0.19 ng/dL), 17 belonging to the treatment group and 12 to the control group. Study groups were comparable, although there was a trend for the treatment group to have more fat mass. No longitudinal changes in body composition were noted in either group, except for a trend to gain fat mass. However, when individuals with age > 65 years were selected, only patients who received radioiodine therapy showed a significant increase in body weight (from 64.1 ± 10.0 to 66.9 ± 9.2 kg), BMI (from 27.3 ± 4.8 to 28.7 ± 4.5 kg/m²), fat mass (from 26.1 ± 8.5 to 27.8 ± 7.9 kg), lean mass (from 36.3 ± 0.4 to 37.4 ± 0.4 kg) and skeletal muscle mass index (SMI) (from 6.0 ± 0.6 to 6.3 ± 0.6 kg/m²). treatment of SHT has impact on body composition in subjects older than 65 years. Weight gain reflects increases in fat and, more interestingly, in lean mass. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  7. Management of the Patient with Aggressive and Resistant Papillary Thyroid Carcinoma

    PubMed Central

    Miftari, Rame; Topçiu, Valdete; Nura, Adem; Haxhibeqiri, Valdete

    2016-01-01

    Purpose: Papillary carcinoma is the most frequent type of thyroid cancer and was considered the most benign of all thyroid carcinomas, with a low risk of distant metastases. However, there are some variants of papillary thyroid carcinoma that have affinity to spread in many organs, such as: lymph nodes, lungs and bones. Aim: The aim of this study was presentation of a case with papillary carcinoma of the thyroid gland, very persistent and resistant in treatment with I 131. Material and results: A man 56 years old were diagnosed with papillary carcinoma of thyroid gland. He underwent a surgical removal of the tumor and right lobe of thyroid gland. With histopathology examination, were confirmed follicular variant of papillary carcinoma pT4. Two weeks later he underwent total thyroidectomy and was treated with 100 mCi of J 131. Six months later, the value of thyroglobulin was found elevated above upper measured limits (more than 500 ng/ml). Patient underwent surgical removal of 10 metastatic lymph nodes in the left side of the neck and has been treated with 145 mCi of radioiodine I 131. The examination after 5 months shows elevation of thyroglobulin, more than 20000 ng/ml and focally uptake of J 131 in the left lung. Patient was treated once again with 150 mCi radioiodine J 131. Whole body scintigraphy was registered focal uptake of radioiodine in the middle of the left collarbone. After a month, patient refers the enlargement of the lymph node in the right side of the neck. Currently patient is being treated with kinase inhibitor drug sorafenib and ibandronate. We have identified first positive response in treatment. Enlarged lymph node in the neck was reduced and the patient began feeling better. Conclusion: This study suggests that some subtypes of papillary thyroid carcinoma appear to have more aggressive biological course. Subtypes of papillary thyroid carcinoma such as diffuse sclerosing carcinoma, tall cell or columnar cell and insular variants, appears to have more aggressive biological course and need early detection and other kind of treatment. PMID:27703298

  8. Effectiveness of radioiodine therapy in treatment of hyperthyroidism.

    PubMed

    Alam, M N; Chakrabarty, R K; Akhter, M; Nahar, N; Swapan, M K; Alam, M M; Nahar, R; Sultana, N; Hallaz, M M; Alam, M M; Uddin, M M; Hossain, M A; Yasmin, S; Islam, M R

    2013-10-01

    The present non randomized clinical trial was conducted in the Center for Nuclear Medicine and Ultrasound, Mymensingh, Bangladesh for duration of one year. Total 30 patients with hyperthyroidism diagnosed by clinical and biochemical profile were included in the study. All patients received radioiodine treatment and regular follow up at 1st month, 3rd month, 6th month & 9th month were done to evaluate clinical and biochemical status and complications. Data were analyzed by computer with SPSS programme using 't' test and chi-square test. In the present study, out of 30 respondents more than three fourth of the respondents (76.6%) were in the age group of 31-50 years followed by less than 30 years are group (16.7%) and rest of respondents were in the age group of more than 50 years (06.7%). Mean±SD and range of age of the respondents were 39.80±10.02 years and 17-65 years respectively. Among the 30 respondents 11(36.7%) were male and 19(63.3%) were female. Male to female ratio was 1:1.73. Out of 30 patients 26(86.7%) presented with goiter and among them 21(80.8%) has diffused goiter and five (19.2%) had nodular goiter. Baseline mean±SD, median, range of serum T₃ level were 5.24±3.62, 4.34, 1.48-14.65nmol/L respectively. Base line mean±SD, median range of serum T₄ level were 192.25±99.17, 201.77, 1.75-336.25nmol/L respectively. Baseline mean±SD, median range of serum TSH level were 6.33±23.93, 0.15-0.07, 130.46nmol/L respectively. In the present study serum T₃, T₄ level among the respondents sharply decrease from baseline to 2nd follow up then gradually decrease from 2nd to 4th follow up. Serum TSH level gradually increases from baseline to 3rd follow up and then gradually decreases from 3rd to 4th follow up. The result showed radioiodine is an effective option for the treatment of thyrotoxicosis.

  9. Molecular environment of stable iodine and radioiodine (129I) in natural organic matter: Evidence inferred from NMR and binding experiments at environmentally relevant concentrations

    NASA Astrophysics Data System (ADS)

    Xu, Chen; Zhong, Junyan; Hatcher, Patrick G.; Zhang, Saijin; Li, Hsiu-Ping; Ho, Yi-Fang; Schwehr, Kathleen A.; Kaplan, Daniel I.; Roberts, Kimberly A.; Brinkmeyer, Robin; Yeager, Chris M.; Santschi, Peter H.

    2012-11-01

    129I is a major by-product of nuclear fission and had become one of the major radiation risk drivers at Department of Energy (DOE) sites. 129I is present at elevated levels in the surface soils of the Savannah River Site (SRS) F-Area and was found to be bound predominantly to soil organic matter (SOM). Naturally bound 127I and 129I to sequentially extracted humic acids (HAs), fulvic acids (FAs) and a water extractable colloid (WEC) were measured in a 129I-contaminated wetland surface soil located on the SRS. WEC is a predominantly colloidal organic fraction obtained from soil re-suspension experiments to mimic the fraction that may be released during groundwater exfiltration, storm water or surface runoff events. For the first time, NMR techniques were applied to infer the molecular environment of naturally occurring stable iodine and radioiodine binding to SOM. Iodine uptake partitioning coefficients (Kd) by these SOM samples at ambient iodine concentrations were also measured and related to quantitative structural analyses by 13C DPMAS NMR and solution state 1H NMR on the eight humic acid fractions. By assessing the molecular environment of iodine, it was found that it was closely associated with the aromatic regions containing esterified products of phenolic and formic acids or other aliphatic carboxylic acids, amide functionalities, quinone-like structures activated by electron-donating groups (e.g., NH2), or a hemicellulose-lignin-like complex with phenyl-glycosidic linkages. However, FAs and WEC contained much greater concentrations of 127I or 129I than HAs. The contrasting radioiodine contents among the three different types of SOM (HAs, FAs and WEC) suggest that the iodine binding environment cannot be explained solely by the difference in the amount of their reactive binding sites. Instead, indirect evidence indicates that the macro-molecular conformation, such as the hydrophobic aliphatic periphery hindering the active aromatic cores and the hydrophilic polysaccharides favoring the access by hydrophilic iodine species, also influences iodine-SOM interactions.

  10. Nutrition in emergencies: Issues involved in ensuring proper nutrition in post-chemical, biological, radiological, and nuclear disaster

    PubMed Central

    Singh, Som Nath

    2010-01-01

    Accidental or deliberate exposure to chemical, biological, radiological, and nuclear (CBRN) agents poses considerable threat throughout the world. Under such conditions, ensuring proper nutrition is a difficult task due to contamination of food available in the affected area. Generally, food is not prepared or served in an environment contaminated by CBRN agents. Foods that are properly packed need to be decontaminated from outside before use. These agents get incorporated in to food chain. Therefore, especially the foliage vegetables, milk and meat products from affected area are not fit for consumption. Potassium iodide has protective role, as radioiodine uptake into the thyroid can be blocked by its pharmacological doses. This is most effective when taken before exposure, but still has significant effects up to five to six hours postexposure. The antioxidant vitamins and minerals may be included in therapeutic feeding programs, as they are known to protect against oxidative stress. Minimum requirement of calories and nutrients are similar to other disasters and are discussed in the present review. PMID:21829320

  11. Nutrition in emergencies: Issues involved in ensuring proper nutrition in post-chemical, biological, radiological, and nuclear disaster.

    PubMed

    Singh, Som Nath

    2010-07-01

    Accidental or deliberate exposure to chemical, biological, radiological, and nuclear (CBRN) agents poses considerable threat throughout the world. Under such conditions, ensuring proper nutrition is a difficult task due to contamination of food available in the affected area. Generally, food is not prepared or served in an environment contaminated by CBRN agents. Foods that are properly packed need to be decontaminated from outside before use. These agents get incorporated in to food chain. Therefore, especially the foliage vegetables, milk and meat products from affected area are not fit for consumption. Potassium iodide has protective role, as radioiodine uptake into the thyroid can be blocked by its pharmacological doses. This is most effective when taken before exposure, but still has significant effects up to five to six hours postexposure. The antioxidant vitamins and minerals may be included in therapeutic feeding programs, as they are known to protect against oxidative stress. Minimum requirement of calories and nutrients are similar to other disasters and are discussed in the present review.

  12. The SPARC Intercomparison of Middle Atmosphere Climatologies

    NASA Technical Reports Server (NTRS)

    Randel, William; Fleming, Eric; Geller, Marvin; Gelman, Mel; Hamilton, Kevin; Karoly, David; Ortland, Dave; Pawson, Steve; Swinbank, Richard; Udelhofen, Petra

    2003-01-01

    Our current confidence in 'observed' climatological winds and temperatures in the middle atmosphere (over altitudes approx. 10-80 km) is assessed by detailed intercomparisons of contemporary and historic data sets. These data sets include global meteorological analyses and assimilations, climatologies derived from research satellite measurements, and historical reference atmosphere circulation statistics. We also include comparisons with historical rocketsonde wind and temperature data, and with more recent lidar temperature measurements. The comparisons focus on a few basic circulation statistics, such as temperature, zonal wind, and eddy flux statistics. Special attention is focused on tropical winds and temperatures, where large differences exist among separate analyses. Assimilated data sets provide the most realistic tropical variability, but substantial differences exist among current schemes.

  13. LIDAR mapping of ozone-episode dynamics in Paris and intercomparison with spot analyzers Supplementary material available at http://link.springer.de/journals/apb

    NASA Astrophysics Data System (ADS)

    Thomasson, A.; Geffroy, S.; Frejafon, E.; Weidauer, D.; Fabian, R.; Godet, Y.; Nominé, M.; Ménard, T.; Rairoux, P.; Moeller, D.; Wolf, J. P.

    Continuous mapping of an ozone episode in Paris in June 1999 has been performed using a differential absorption lidar system. The 2D ozone concentration vertical maps recorded over 33 h at the Champ de Mars are compiled in a video clip that gives access to local photochemical dynamics with unprecedented precision. The lidar data are compared over the whole period with point monitors located at 0-, 50-, and 300-m altitudes on the Eiffel Tower. Very good agreement is found when spatial resolution, acquisition time, and required concentration accuracy are optimized. Sensitivity to these parameters for successful intercomparison in urban areas is discussed.

  14. An intercomparison of longwave measurements by ERBE radiometers on the NOAA-9 and ERBS satellites

    NASA Technical Reports Server (NTRS)

    House, Frederick B.

    1989-01-01

    Two instrument modules of each satellite on which the Earth Radiation Budget Experiment (ERBE) is orbiting observe components of the earth radiation budget with three different scales of earth view. An intercomparison of longwave measurements by these instruments provides relative information concerning radiometric performance at satellite altitude, techniques of estimating upwelling exitances, and an end-to-end evaluation of the data processing system. Results indicate that the ERBE radiometers are mildly sensitive to varying thermal loads from the spacecraft and/or the earth-space environment. Radiometric variations at the satellite and methods of data interpretation contribute about equally to the uncertainty of radiant exitances from the earth.

  15. Intercomparison of analytical methods for arsenic speciation in human urine.

    PubMed

    Crecelius, E; Yager, J

    1997-06-01

    An intercomparison exercise was conducted for the quantification of arsenic species in spiked human urine. The primary objective of the exercise was to determine the variance among laboratories in the analysis of arsenic species such as inorganic As (As+3 and As+5), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA). Laboratories that participated had previous experience with arsenic speciation analysis. The results of this interlaboratory comparison are encouraging. There is relatively good agreement on the concentrations of these arsenic species in urine at concentrations that are relevant to research on the metabolism of arsenic in humans and other mammals. Both the accuracy and precision are relatively poor for arsenic concentrations of less than about 5 micrograms/l.

  16. An evaluation of 20th century climate for the Southeastern United States as simulated by Coupled Model Intercomparison Project Phase 5 (CMIP5) global climate models

    USGS Publications Warehouse

    David E. Rupp,

    2016-05-05

    The 20th century climate for the Southeastern United States and surrounding areas as simulated by global climate models used in the Coupled Model Intercomparison Project Phase 5 (CMIP5) was evaluated. A suite of statistics that characterize various aspects of the regional climate was calculated from both model simulations and observation-based datasets. CMIP5 global climate models were ranked by their ability to reproduce the observed climate. Differences in the performance of the models between regions of the United States (the Southeastern and Northwestern United States) warrant a regional-scale assessment of CMIP5 models.

  17. A large-scale intercomparison of stratospheric vertical distributions of NO2 and BrO retrieved from the SCIAMACHY limb measurements and ground-based twilight observations

    NASA Astrophysics Data System (ADS)

    Rozanov, Alexei; Hendrick, Francois; Lotz, Wolfhardt; van Roozendael, Michel; Bovensmann, Heinrich; Burrows, John P.

    This study is devoted to the intercomparison of NO2 and BrO vertical profiles obtained from the satellite and ground-based measurements. Although, the ground-based observations are performed only at selected locations, they have a great potential to be used for the validation of satellite measurements since continuous long-term measurement series performed with the same instruments are available. Thus, long-term trends in the observed species can be analyzed and intercompared. Previous intercomparisons of the vertical distributions of NO2 and BrO retrieved from SCIAMACHY limb measurements at the University of Bremen and obtained at IASB-BIRA by applying a profiling technique to ground-based zenith-sky DOAS observations have shown a good agreement between the results of completely different measurement techniques. However, only a relatively short time period of one year was analyzed so far which do not allow investigating seasonal variations and trends. Furthermore, some minor discrepancies are still to be analyzed. In the current study, several years datasets obtained at Observatoire de Haute-Provence (OHP) in France and in Harestua in Norway will be compared to the retrievals of SCIAMACHY limb measurements. Seasonal and annual variations will be analyzed and possible reasons for the remaining discrepancies will be discussed.

  18. Constraints and potentials of future irrigation water availability on agricultural production under climate change

    PubMed Central

    Elliott, Joshua; Deryng, Delphine; Müller, Christoph; Frieler, Katja; Konzmann, Markus; Gerten, Dieter; Glotter, Michael; Flörke, Martina; Wada, Yoshihide; Best, Neil; Eisner, Stephanie; Fekete, Balázs M.; Folberth, Christian; Foster, Ian; Gosling, Simon N.; Haddeland, Ingjerd; Khabarov, Nikolay; Ludwig, Fulco; Masaki, Yoshimitsu; Olin, Stefan; Rosenzweig, Cynthia; Ruane, Alex C.; Satoh, Yusuke; Schmid, Erwin; Stacke, Tobias; Tang, Qiuhong; Wisser, Dominik

    2014-01-01

    We compare ensembles of water supply and demand projections from 10 global hydrological models and six global gridded crop models. These are produced as part of the Inter-Sectoral Impacts Model Intercomparison Project, with coordination from the Agricultural Model Intercomparison and Improvement Project, and driven by outputs of general circulation models run under representative concentration pathway 8.5 as part of the Fifth Coupled Model Intercomparison Project. Models project that direct climate impacts to maize, soybean, wheat, and rice involve losses of 400–1,400 Pcal (8–24% of present-day total) when CO2 fertilization effects are accounted for or 1,400–2,600 Pcal (24–43%) otherwise. Freshwater limitations in some irrigated regions (western United States; China; and West, South, and Central Asia) could necessitate the reversion of 20–60 Mha of cropland from irrigated to rainfed management by end-of-century, and a further loss of 600–2,900 Pcal of food production. In other regions (northern/eastern United States, parts of South America, much of Europe, and South East Asia) surplus water supply could in principle support a net increase in irrigation, although substantial investments in irrigation infrastructure would be required. PMID:24344283

  19. The First SIMBIOS Radiometric Intercomparison (SIMRIC-1), April-September 2001

    NASA Technical Reports Server (NTRS)

    Meister, Gerhard; Abel, Peter; McClain, Charles; Barnes, Robert; Fargion, Giulietta; Cooper, John; Davis, Curtiss; Korwan, Daniel; Godin, Mike; Maffione, Robert

    2002-01-01

    This report describes the first SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) Radiometric Intercomparison (SIMRIC-1). The purpose of the SIMRIC-1 is to ensure a common radiometric scale of the calibration facilities that are engaged in calibrating in situ radiometers used for ocean color related research and to document the calibration procedures and protocols. SIMBIOS staff visited the seven participating laboratories for at least two days each. The SeaWiFS Transfer Radiometer SXR-II measured the calibration radiances produced in the laboratories. The measured radiances were compared with the radiances expected by the laboratories. Typically, the measured radiances were higher than the expected radiances by 0 to 2%. This level of agreement is satisfactory. Several issues were identified, where the calibration protocols need to be improved, especially the reflectance calibration of the reference plaques and the distance correction when using the irradiance standards at distances greater than the 50 cm. The responsivity of the SXR-II changed between 0.3% (channel 6) and 1.6% (channel 2) from December 2000 to December 2001. Monitoring the SXR-II with a portable light source showed a linear drift of the calibration, except for channel 1, where a 2% drop occurred in summer.

  20. IPRT polarized radiative transfer model intercomparison project - Phase A

    NASA Astrophysics Data System (ADS)

    Emde, Claudia; Barlakas, Vasileios; Cornet, Céline; Evans, Frank; Korkin, Sergey; Ota, Yoshifumi; Labonnote, Laurent C.; Lyapustin, Alexei; Macke, Andreas; Mayer, Bernhard; Wendisch, Manfred

    2015-10-01

    The polarization state of electromagnetic radiation scattered by atmospheric particles such as aerosols, cloud droplets, or ice crystals contains much more information about the optical and microphysical properties than the total intensity alone. For this reason an increasing number of polarimetric observations are performed from space, from the ground and from aircraft. Polarized radiative transfer models are required to interpret and analyse these measurements and to develop retrieval algorithms exploiting polarimetric observations. In the last years a large number of new codes have been developed, mostly for specific applications. Benchmark results are available for specific cases, but not for more sophisticated scenarios including polarized surface reflection and multi-layer atmospheres. The International Polarized Radiative Transfer (IPRT) working group of the International Radiation Commission (IRC) has initiated a model intercomparison project in order to fill this gap. This paper presents the results of the first phase A of the IPRT project which includes ten test cases, from simple setups with only one layer and Rayleigh scattering to rather sophisticated setups with a cloud embedded in a standard atmosphere above an ocean surface. All scenarios in the first phase A of the intercomparison project are for a one-dimensional plane-parallel model geometry. The commonly established benchmark results are available at the IPRT website.

  1. The 1994 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers

    PubMed Central

    Thompson, Ambler; Early, Edward A.; DeLuisi, John; Disterhoft, Patrick; Wardle, David; Kerr, James; Rives, John; Sun, Yongchen; Lucas, Timothy; Mestechkina, Tanya; Neale, Patrick

    1997-01-01

    Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, the first North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held September 19–29, 1994 at Table Mountain outside Boulder, Colorado, USA. This Intercomparison was coordinated by the National Institute of Standards and Technology and the National Oceanic and Atmospheric Administration (NOAA). Participating agencies were the Environmental Protection Agency, National Science Foundation, Smithsonian Environmental Research Center, and Atmospheric Environment Service, Canada. Instruments were characterized for wavelength accuracy, bandwidth, stray-light rejection, and spectral irradiance responsivity, the latter with a NIST standard lamp calibrated to operate in the horizontal position. The spectral irradiance responsivity was determined once indoors and twice outdoors, and demonstrated that, while the responsivities changed upon moving the instruments, they were relatively stable when the instruments remained outdoors. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST standard lamp, and a simple convolution technique to account for the different bandwidths of the instruments, the measured solar irradiances agreed within 5 %. PMID:27805148

  2. LLNL Results from CALIBAN-PROSPERO Nuclear Accident Dosimetry Experiments in September 2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lobaugh, M. L.; Hickman, D. P.; Wong, C. W.

    2015-05-21

    Lawrence Livermore National Laboratory (LLNL) uses thin neutron activation foils, sulfur, and threshold energy shielding to determine neutron component doses and the total dose from neutrons in the event of a nuclear criticality accident. The dosimeter also uses a DOELAP accredited Panasonic UD-810 (Panasonic Industrial Devices Sales Company of America, 2 Riverfront Plaza, Newark, NJ 07102, U.S.A.) thermoluminescent dosimetery system (TLD) for determining the gamma component of the total dose. LLNL has participated in three international intercomparisons of nuclear accident dosimeters. In October 2009, LLNL participated in an exercise at the French Commissariat à l’énergie atomique et aux énergies alternativesmore » (Alternative Energies and Atomic Energy Commission- CEA) Research Center at Valduc utilizing the SILENE reactor (Hickman, et.al. 2010). In September 2010, LLNL participated in a second intercomparison at CEA Valduc, this time with exposures at the CALIBAN reactor (Hickman et al. 2011). This paper discusses LLNL’s results of a third intercomparison hosted by the French Institut de Radioprotection et de Sûreté Nucléaire (Institute for Radiation Protection and Nuclear Safety- IRSN) with exposures at two CEA Valduc reactors (CALIBAN and PROSPERO) in September 2014. Comparison results between the three participating facilities is presented elsewhere (Chevallier 2015; Duluc 2015).« less

  3. An intercomparison of instrumentation for tropospheric measurements of dimethyl sulfide: Aircraft results for concentrations at the parts-per-trillion level

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Warren, Linda S.; Davis, Douglas D.; Andreae, Meinrat O.; Bandy, Alan R.; Ferek, Ronald J.; Johnson, James E.; Saltzman, Eric S.; Cooper, David J.

    1993-01-01

    This paper reports results from NASA's Chemical Instrumentation and Test Evaluation (CITE 3) during which airborne measurements of dimethyl sulfide (DMS) from six instruments were intercompared. Represented by the six instruments are three fundamentally different detection principles (flame photometric, mass spectrometric, and electron capture after fluorination); three collection/preconcentration methods (cryogenic, gold wool absorption, and polymer absorbent); and three types of oxidant scrubbers (solid phase alkaline, aqueous reactor, and cotton). The measurements were made over the Atlantic Ocean in August/September 1989 during flights from NASA's Wallops Flight Center, Virginia, and Natal, Brazil. The majority of the intercomparisons are at DMS mixing ratios less than 50 pptv. Results show that instrument agreement is of the order of a few pptv for mixing ratios less than 50 pptv and to within about 15% above 50 pptv. Statistically significant (95% confidence) measurement biases were noted among some of the techniques. However, in all cases, any bias is small and within the accuracy of the measurements and prepared DMS standards. Thus, we conclude that the techniques intercompared during CITE 3 provide equally valid measurements of DMS in the range of a few pptv to 100 pptv (upper range of the intercomparisons).

  4. Large-Scale Features of Pliocene Climate: Results from the Pliocene Model Intercomparison Project

    NASA Technical Reports Server (NTRS)

    Haywood, A. M.; Hill, D.J.; Dolan, A. M.; Otto-Bliesner, B. L.; Bragg, F.; Chan, W.-L.; Chandler, M. A.; Contoux, C.; Dowsett, H. J.; Jost, A.; hide

    2013-01-01

    Climate and environments of the mid-Pliocene warm period (3.264 to 3.025 Ma) have been extensively studied.Whilst numerical models have shed light on the nature of climate at the time, uncertainties in their predictions have not been systematically examined. The Pliocene Model Intercomparison Project quantifies uncertainties in model outputs through a coordinated multi-model and multi-mode data intercomparison. Whilst commonalities in model outputs for the Pliocene are clearly evident, we show substantial variation in the sensitivity of models to the implementation of Pliocene boundary conditions. Models appear able to reproduce many regional changes in temperature reconstructed from geological proxies. However, data model comparison highlights that models potentially underestimate polar amplification. To assert this conclusion with greater confidence, limitations in the time-averaged proxy data currently available must be addressed. Furthermore, sensitivity tests exploring the known unknowns in modelling Pliocene climate specifically relevant to the high latitudes are essential (e.g. palaeogeography, gateways, orbital forcing and trace gasses). Estimates of longer-term sensitivity to CO2 (also known as Earth System Sensitivity; ESS), support previous work suggesting that ESS is greater than Climate Sensitivity (CS), and suggest that the ratio of ESS to CS is between 1 and 2, with a "best" estimate of 1.5.

  5. The Second SIMBIOS Radiometric Intercomparison (SIMRIC-2), March-November 2002. Volume 2

    NASA Technical Reports Server (NTRS)

    Meister, Gerhard; Abel, Peter; Carder, Kendall; Chapin, Albert; Clark, Dennis; Cooper, John; Davis, Curtis; English, David; Fargion, Giulietta; Feinholz, Michael; hide

    2003-01-01

    The second SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) Radiometric Intercomparison (SIMRIC-2) was carried out in 2002. The purpose of the SIMRIC's was to ensure a common radiometric scale among the calibration facilities that are engaged in calibrating in-situ radiometrics used for ocean color-related research and to document the calibration procedures and protocols. The SeaWIFS Transfer Radiometer (SXR-II) measured the calibration radiances at six wavelengths from 411nm to 777nm in the ten laboratories participating in the SIMRIC-2. The measured radiances were compared with the radiances expected by the laboratories. The agreement was within the combined uncertainties for all but two laboratories. Likely error sources were identified in these laboratories and corrective measures were implemented. NIST calibrations in December 2001 and January 2003 showed changes ranging from -0.6% to +0.7% for the six SXR-II channels. Two independent light sources were used to monitor changes in the SXR-II responsivity between the NIST calibrations. A 2% variation of the responsivity of channel 1 of the SXR-II was detected, and the SXR-II responsivity was corrected using the monitoring data. This report also compared directional reflectance calibrations of a Spectralon plaque by different calibration facilities

  6. Mild, Pd-catalyzed stannylation of radioiodination targets

    PubMed Central

    Pickett, Julie E.; Váradi, András; Palmer, Travis C.; Grinnell, Steven G.; Schrock, Joel M.; Pasternak, Gavril W.; Karimov, Rashad R.; Majumdar, Susruta

    2015-01-01

    Trialkylstannanes are versatile precursors for chemical transformations, including radiolabeling with a variety of halogens, particularly iodine. In the present work a convenient, Pd-mediated stannylation method is presented that can be performed in an open flask. The method is selective for aryl iodides allowing selective stannylations in the presence of other halogen atoms. The reaction conditions are mild, making the method compatible with chemically sensitive bioactive compounds. PMID:25777268

  7. Precursors to radiopharmaceutical agents for tissue imaging

    DOEpatents

    Srivastava, Prem C.; Knapp, Jr., Furn F.

    1988-01-01

    A class of radiolabeled compounds to be used in tissue imaging that exhibits rapid brain uptake, good brain:blood radioactivity ratios, and long retention times. The imaging agents are more specifically radioiodinated aromatic amines attached to dihydropyridine carriers, that exhibit heart as well as brain specificity. In addition to the radiolabeled compounds, classes of compounds are also described that are used as precursors and intermediates in the preparation of the imaging agents.

  8. Guidelines for the treatment of childhood-onset Graves’ disease in Japan, 2016

    PubMed Central

    Minamitani, Kanshi; Sato, Hirokazu; Ohye, Hidemi; Harada, Shohei; Arisaka, Osamu

    2017-01-01

    Abstract. Purpose behind developing these guidelines: Over one decade ago, the “Guidelines for the Treatment of Graves’ Disease with Antithyroid Drug, 2006” (Japan Thyroid Association (JTA)) were published as the standard drug therapy protocol for Graves’ disease. The “Guidelines for the Treatment of Childhood-Onset Graves’ Disease with Antithyroid Drug in Japan, 2008” were published to provide guidance on the treatment of pediatric patients. Based on new evidence, a revised version of the “Guidelines for the Treatment of Graves’ Disease with Antithyroid Drug, 2006” (JTA) was published in 2011, combined with the “Handbook of Radioiodine Therapy for Graves’ Disease 2007” (JTA). Subsequently, newer findings on pediatric Graves’ disease have been reported. Propylthiouracil (PTU)-induced serious hepatopathy is an important problem in pediatric patients. The American Thyroid Association’s guidelines suggest that, in principle, physicians must not administer PTU to children. On the other hand, the “Guidelines for the Treatment of Graves’ Disease with Antithyroid Drug, 2011” (JTA) state that radioiodine therapy is no longer considered a “fundamental contraindication” in children. Therefore, the “Guidelines for the Treatment of Childhood-Onset Graves’ Disease with Antithyroid Drug in Japan, 2008” required revision. PMID:28458457

  9. Greater Efficacy of Total Thyroidectomy versus Radioiodine Therapy on Hyperthyroidism and Thyroid-Stimulating Immunoglobulin Levels in Patients with Graves' Disease Previously Treated with Antithyroid Drugs.

    PubMed

    Kautbally, Shakeel; Alexopoulou, Orsalia; Daumerie, Chantal; Jamar, François; Mourad, Michel; Maiter, Dominique

    2012-07-01

    We compared the effects of total thyroidectomy (TTx) and radioiodine (RAI) administration on the course of thyroid hormones and thyroid-stimulating immunoglobulins (TSI) in patients with Graves' disease. We retrospectively studied 80 patients initially treated with antithyroid drugs and requiring either RAI (8.3 ± 1.7 mCi of (131)I; n = 40) or TTx (n = 40) as second-line therapy. The TTx and RAI groups were not different, except for larger goiter, higher FT3 and more frequent Graves' orbitopathy at diagnosis in the surgery group (p < 0.05). A persistent remission of hyperthyroidism was observed in 97% of operated patients versus 73% of the RAI patients at 3 years (p < 0.01). TTx was followed by a rapid and steady decrease in TSI during the first 9 months, while a surge of antibodies was observed during the first 6 months after RAI, followed by a slow decrease over the next 18 months. At the last visit, high TSI levels were still observed in 18 and 60% of patients in the surgery and RAI groups, respectively (p < 0.001). TTx is more efficient than RAI to induce a rapid and permanent correction of hyperthyroidism and TSI decrease in patients previously treated with antithyroid drugs.

  10. A case of metastatic follicular thyroid carcinoma complicated with Graves' disease after total thyroidectomy.

    PubMed

    Aoyama, Mariko; Takizawa, Hiromitsu; Tsuboi, Mitsuhiro; Nakagawa, Yasushi; Tangoku, Akira

    2017-12-28

    Thyroid cancer and Graves' disease may present simultaneously in one patient. The incidence of the development of hyperthyroidism from metastatic differentiated thyroid carcinoma is rare. We herein report a case of metastatic follicular carcinoma complicated with Graves' disease after total thyroidectomy. A 57-year-old woman underwent right hemithyroidectomy for follicular carcinoma. Metastatic lesions appeared in the lungs and skull two years after the first surgery, and remnant thyroidectomy was performed for radioactive iodine-131 (RAI) therapy, during which the TSH receptor antibody (TRAb) was found to be negative. The patient was treated with RAI therapy four times for four years and was receiving levothyroxine suppressive therapy. Although radioiodine uptake was observed in the lesions after the fourth course of RAI therapy, metastatic lesions had progressed. Four years after the second surgery, she had heart palpitations and tremors. Laboratory data revealed hyperthyroidism and positive TRAb. She was diagnosed with Graves' disease and received a fifth course of RAI therapy. 131I scintigraphy after RAI therapy showed strong radioiodine uptake in the metastatic lesions. As a result, the sizes and numbers of metastatic lesions decreased, and thyroid function improved. Metastatic lesions produced thyroid hormone and caused hyperthyroidism. RAI therapy was effective for Graves' disease and thyroid carcinoma.

  11. Common spectrum of polypeptides occurs in secretion granule membranes of different exocrine glands

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cameron, R.S.; Cameron, P.L.; Castle, J.D.

    1986-10-01

    A highly purified membrane preparation from rat parotid secretion granules has been used as a comparative probe to examine the extent of compositional overlap in granule membranes of three other exocrine secretory tissues - pancreatic, lacrimal, and submandibular - from several standpoints. First, indirect immunofluorescent studies using a polyclonal polyspecific anti-parotid granule membrane antiserum has indicated a selective staining of granule membrane profiles in all acinar cells of all tissues. Second, highly purified granule membrane subfractions have been isolated from each exocrine tissue; comparative two-dimensional (isoelectric focusing; SDS) PAGE of radioiodinated granule membranes has identified 10-15 polypeptides of identical pImore » and apparent molecular mass. These species are likely to be integral membrane components since they are not extracted by either saponin-sodium sulfate or sodium carbonate (pH 11.5) treatments, and they do not have counterparts in the granule content. Finally, the identity among selected parotid and pancreatic radioiodinated granule membrane polypeptides has been documented using two-dimensional peptide mapping of chymotryptic and tryptic digests. These findings clearly indicate that exocrine secretory granules, irrespective of the nature of stored secretion, comprise a type of vesicular carrier with a common (and probably refined) membrane composition. Conceivably, the polypeptides identified carry out general functions related to exocrine secretion.« less

  12. Thyroid nodules, thyroid function and dietary iodine in the Marshall islands.

    PubMed

    Takahashi, T; Fujimori, K; Simon, S L; Bechtner, G; Edwards, R; Trott, K R

    1999-08-01

    Thyroid nodules have been found to be common in the population of the Marshall Islands. This has been attributed to potential exposure of radioiodines from the nuclear weapons tests on Bikini and Eniwetok between 1946 and 1958. In order to get a full picture of thyroid pathology in the Marshallese population potentially exposed to radioactive fallout we performed a large thyroid screening programme using palpation, high resolution ultrasound and fine needle biopsies of palpable nodules. In addition, various parameters of thyroid function (free T3, free T4, thyroid stimulating hormone [TSH]) and anti-thyroid antibodies were examined in large proportions of the total population at risk. Since dietary iodine deficiency is an established risk factor for thyroid nodules, iodine concentration in urine samples of 362 adults and 119 children was measured as well as the iodine content of selected staple food products. The expected high prevalence of thyroid nodules was confirmed. There was no indication of an increased rate of impaired thyroid function in the Marshallese population. A moderate degree of iodine deficiency was found which may be responsible for some of the increased prevalence of thyroid nodules in the Marshallese population. Studies on the relationship between exposure to radioiodines and thyroid nodules need to take dietary iodine deficiency into account in the interpretation of findings.

  13. Survey of management of solitary thyroid nodules in Germany.

    PubMed

    Dietlein, M; Wegscheider, K; Vaupel, R; Schmidt, M; Schicha, H

    2008-01-01

    To compare the opinions of practitioners in primary care with those of thyroid specialists in Germany on the management of solitary thyroid nodules (Papillon 2005). Questionnaires were filled in by 2,191 practitioners and 297 thyroid specialists between June 1 and September 30, 2005. The test cases and their modifications described a solitary thyroid nodule of 2-3 cm with different levels of thyroid function and a hypoechogenic nodule of 1 cm in diameter. TSH determination and sonography were found to be standard procedures, followed by scintigraphy (selected by 84.7% of practitioners and 95.1% of specialists, p < 0.001) and fine needle aspiration cytology (54.5% of practitioners, 57.4% of specialists). For a hypoechogenic nodule calcitonin determination was advocated by 54.0% of endocrinologists and by 32.2% of nuclear medicine physicians (p < 0.001). A euthyroid solitary thyroid nodule would be treated medically by 77.8% of practitioners and by 85.7% of specialists, the combination of levothyroxine and iodine being clearly preferred (60.9% of practitioners and 67.1% of specialists). For a hyperfunctioning nodule the preference of radioiodine therapy was significantly higher in the specialist group (88.8%) than among the practitioners (52.2%). The main differences of opinion between practitioners and specialists focused on calcitonin screening and referral to radioiodine therapy.

  14. [Blocking of the thyroid against I-131 following a nuclear disaster].

    PubMed

    Kroizman-Sheiner, Einat; Brickner, Dov; Canfi, Ayala; Schwarzfuchs, Dan

    2005-07-01

    The Chernobyl accident, the recent terrorists' attacks and constant threats, have all once again evoked the fear of a nuclear disaster, in Israel and worldwide. Iodine-131 is a major fission product of nuclear reactors and is highly likely to be released into the atmosphere in severe nuclear disasters. The radioiodine is released as a gas, easily spreads over large areas and is easily absorbed via the respiratory system. Iodine-131 emits gamma and beta radiation in high energies, and is readily absorbed by the thyroid which is a target organ for iodine. The resulting exposure to the thyroid might be very high. A sharp increase in thyroid cancer incidence in children was observed following the Chernobyl accident. This article reviews the medical knowledge about strategies and medications aimed at minimizing the absorption of radioiodine into the thyroid. In addition to regular safety means such as sheltering, restriction of locally produced food products and relocation of the population, the best prophylaxis against thyroid exposure is overloading the gland with stable iodine (as potassium iodide), as soon as possible. Recently, the Israeli government decided to distribute Potassium Iodide tablets to the population in the vicinity of the two nuclear research centers in the country. When this treatment is contraindicated, iodine free thionamides or potassium perchlorate are suggested.

  15. Current Advances in Thyroid Cancer Management. Are We Ready for the Epidemic Rise of Diagnoses?

    PubMed

    Rusinek, Dagmara; Chmielik, Ewa; Krajewska, Jolanta; Jarzab, Michal; Oczko-Wojciechowska, Malgorzata; Czarniecka, Agnieszka; Jarzab, Barbara

    2017-08-22

    A rising incidence of thyroid cancers (TCs) mainly small tumors, observed during recent years, lead to many controversies regarding treatment strategies. TCs represent a distinct molecular background and clinical outcome. Although in most cases TCs are characterized by a good prognosis, there are some aggressive forms, which do not respond to standard treatment. There are still some questions, which have to be resolved to avoid dangerous simplifications in the clinical management. In this article, we focused on the current advantages in preoperative molecular diagnostic tests and histopathological examination including noninvasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP). We discussed the controversies regarding the extent of thyroid surgery and adjuvant radioiodine therapy, as well as new treatment modalities for radioiodine-refractory differentiated thyroid cancer (RR-DTC). Considering medullary thyroid cancer (MTC), we analyzed a clinical management based on histopathology and RET (ret proto-oncogene) mutation genotype, disease follow-up with a special attention to serum calcitonin doubling time as an important prognostic marker, and targeted therapy applied in advanced MTC. In addition, we provided some data regarding anaplastic thyroid cancer (ATC), a highly lethal neoplasm, which lead to death in nearly 100% of patients due to the lack of effective treatment options.

  16. The management of Graves' disease in New Zealand 2014.

    PubMed

    Cox, Stephanie C; Tamatea, Jade Au; Conaglen, John V; Elston, Marianne S

    2016-06-10

    Treatment options for Graves' disease (GD), namely anti-thyroid drugs (ATD), surgery or radioiodine (RAI), have not changed over the past two decades. There is no 'gold-standard' treatment for GD. To assess whether the management of GD in New Zealand has changed since the previous 1991 New Zealand survey and compare current management with that of contemporary international studies. We conducted an online survey of New Zealand physicians currently practising internal medicine, diabetes and/or endocrinology, using the cases and questions from the original European and 1991 New Zealand studies. The first-line use of RAI was 5.5%, compared to 41% in the 1991 New Zealand survey. This corresponded to an increase in ATD use, while the rates of surgery as a first-line treatment have remained static over time. New Zealand physicians use technetium scanning for diagnosis, whereas ultrasound and radioiodine uptake were the most commonly selected investigations by European and North American physicians, respectively. The pattern of ATD use in pregnancy was similar to international practice. Treatment of GD in New Zealand has shifted away from the use of RAI as first line treatment. There are significant differences in the investigation and treatment of Grave's disease between New Zealand, Europe and North America.

  17. [Procedure guidelines for radioiodine therapy of differentiated thyroid cancer (version 2)].

    PubMed

    Dietlein, M; Dressler, J; Farahati, J; Grünwald, F; Leisner, B; Moser, E; Reiners, C; Schicha, H; Schober, O

    2004-08-01

    The procedure guidelines for radioiodine therapy (RIT) of differentiated thyroid cancer (version 2) are the counter-part to the procedure guidelines for (131)I whole-body scintigraphy (version 2) and specify the interdisciplinary guidelines for thyroid cancer of the Deutsche Krebsgesellschaft and the Deutsche Gesellschaft für Chirurgie concerning the nuclear medicine part. Compared with version 1 facultative options for RIT can be chosen in special cases: ablative RIT for papillary microcarcinoma

  18. Methods for Validation and Intercomparison of Remote Sensing and In situ Ice Water Measurements: Case Studies from CRYSTAL-FACE and Model Results

    NASA Technical Reports Server (NTRS)

    Sayres, D.S.; Pittman, J. V.; Smith, J. B.; Weinstock, E. M.; Anderson, J. G.; Heymsfield, G.; Li, L.; Fridlind, A.; Ackerman, A. S.

    2004-01-01

    Remote sensing observations, such as those from AURA, are necessary to understand the role of cirrus in determining the radiative and humidity budgets of the upper troposphere. Using these measurements quantitatively requires comparisons with in situ measurements that have previously been validated. However, a direct comparison of remote and in situ measurements is difficult due to the requirement that the spatial and temporal overlap be sufficient in order to guarantee that both instruments are measuring the same air parcel. A difficult as this might be for gas phase intercomparisons, cloud inhomogeneities significantly exacerbate the problem for cloud ice water content measurements. The CRYSTAL-FACE mission provided an opportunity to assess how well such intercomparisons can be performed and to establish flight plans that will be necessary for validation of future satellite instruments. During CRYSTAL-FACE, remote and in situ instruments were placed on different aircraft (NASA's ER-2 and WB-59, and the two planes flew in tandem so that the in situ payload flew in the field of view of the remote instruments. We show here that, even with this type of careful flight planning, it is not always possible to guarantee that remote and in situ instruments are viewing the same air parcel. We use ice water data derived from the in situ Harvard Total Water (HV-TW) instrument, and the remote Goddard Cloud Radar System (CRS) and show that agreement between HV-TW and CRS is a strong function of the horizontal separation and the time delay between the aircraft transects. We also use a cloud model to simulate possible trajectories through a cloud and evaluate the use of statistical analysis in determining the agreement between the two instruments. This type of analysis should guide flight planning for future intercomparison efforts, whether for aircraft or satellite-borne instrumentation.

  19. Real-time analysis of δ13C- and δD-CH4 in ambient air with laser spectroscopy: method development and first intercomparison results

    NASA Astrophysics Data System (ADS)

    Eyer, S.; Tuzson, B.; Popa, M. E.; van der Veen, C.; Röckmann, T.; Rothe, M.; Brand, W. A.; Fisher, R.; Lowry, D.; Nisbet, E. G.; Brennwald, M. S.; Harris, E.; Zellweger, C.; Emmenegger, L.; Fischer, H.; Mohn, J.

    2015-08-01

    In situ and simultaneous measurement of the three most abundant isotopologues of methane using mid-infrared laser absorption spectroscopy is demonstrated. A field-deployable, autonomous platform is realized by coupling a compact quantum cascade laser absorption spectrometer (QCLAS) to a preconcentration unit, called TRace gas EXtractor (TREX). This unit enhances CH4 mole fractions by a factor of up to 500 above ambient levels and quantitatively separates interfering trace gases such as N2O and CO2. The analytical precision of the QCLAS isotope measurement on the preconcentrated (750 ppm, parts-per-million, μmole/mole) methane is 0.1 and 0.5 ‰ for δ13C- and δD-CH4 at 10 min averaging time. Based on replicate measurements of compressed air during a two-week intercomparison campaign, the repeatability of the TREX-QCLAS was determined to be 0.19 and 1.9 ‰ for δ13C and δD-CH4, respectively. In this intercomparison campaign the new in situ technique is compared to isotope-ratio mass-spectrometry (IRMS) based on glass flask and bag sampling and real time CH4 isotope analysis by two commercially available laser spectrometers. Both laser-based analyzers were limited to methane mole fraction and δ13C-CH4 analysis, and only one of them, a cavity ring down spectrometer, was capable to deliver meaningful data for the isotopic composition. After correcting for scale offsets, the average difference between TREX-QCLAS data and bag/flask sampling-IRMS values are within the extended WMO compatibility goals of 0.2 and 5 ‰ for δ13C- and δD-CH4, respectively. Thus, the intercomparison also reveals the need for reference air samples with accurately determined isotopic composition of CH4 to further improve the interlaboratory compatibility.

  20. An assessment of two automated snow water equivalent instruments during the WMO Solid Precipitation Intercomparison Experiment

    NASA Astrophysics Data System (ADS)

    Smith, Craig D.; Kontu, Anna; Laffin, Richard; Pomeroy, John W.

    2017-01-01

    During the World Meteorological Organization (WMO) Solid Precipitation Intercomparison Experiment (SPICE), automated measurements of snow water equivalent (SWE) were made at the Sodankylä (Finland), Weissfluhjoch (Switzerland) and Caribou Creek (Canada) SPICE sites during the northern hemispheric winters of 2013/14 and 2014/15. Supplementary intercomparison measurements were made at Fortress Mountain (Kananaskis, Canada) during the 2013/14 winter. The objectives of this analysis are to compare automated SWE measurements with a reference, comment on their performance and, where possible, to make recommendations on how to best use the instruments and interpret their measurements. Sodankylä, Caribou Creek and Fortress Mountain hosted a Campbell Scientific CS725 passive gamma radiation SWE sensor. Sodankylä and Weissfluhjoch hosted a Sommer Messtechnik SSG1000 snow scale. The CS725 operating principle is based on measuring the attenuation of soil emitted gamma radiation by the snowpack and relating the attenuation to SWE. The SSG1000 measures the mass of the overlying snowpack directly by using a weighing platform and load cell. Manual SWE measurements were obtained at the intercomparison sites on a bi-weekly basis over the accumulation-ablation periods using bulk density samplers. These manual measurements are considered to be the reference for the intercomparison. Results from Sodankylä and Caribou Creek showed that the CS725 generally overestimates SWE as compared to manual measurements by roughly 30-35 % with correlations (r2) as high as 0.99 for Sodankylä and 0.90 for Caribou Creek. The RMSE varied from 30 to 43 mm water equivalent (mm w.e.) and from 18 to 25 mm w.e. at Sodankylä and Caribou Creek, which had respective SWE maximums of approximately 200 and 120 mm w.e. The correlation at Fortress Mountain was 0.94 (RMSE of 48 mm w.e. with a maximum SWE of approximately 650 mm w.e.) with no systematic overestimation. The SSG1000 snow scale, having a different measurement principle, agreed quite closely with the manual measurements at Sodankylä and Weissfluhjoch throughout the periods when data were available (r2 as high as 0.99 and RMSE from 8 to 24 mm w.e. at Sodankylä and from 56 to 59 mm w.e. at Weissfluhjoch, where maximum SWE was approximately 850 mm w.e.). When the SSG1000 was compared to the CS725 at Sodankylä, the agreement was linear until the start of ablation when the positive bias in the CS725 increases substantially relative to the SSG1000. Since both Caribou Creek and Sodankylä have sandy soil, water from the snowpack readily infiltrates into the soil during melt, even if the soil is frozen. However, the CS725 does not differentiate this water from the unmelted snow. This issue can be identified, at least during the late spring ablation period, with soil moisture and temperature observations like those measured at Caribou Creek. With a less permeable soil and surface runoff, the increase in the instrument bias during ablation is not as significant, as shown by the Fortress Mountain intercomparison.

  1. The new GFDL global atmosphere and land model AM2-LM2: Evaluation with prescribed SST simulations

    USGS Publications Warehouse

    Anderson, J.L.; Balaji, V.; Broccoli, A.J.; Cooke, W.F.; Delworth, T.L.; Dixon, K.W.; Donner, L.J.; Dunne, K.A.; Freidenreich, S.M.; Garner, S.T.; Gudgel, R.G.; Gordon, C.T.; Held, I.M.; Hemler, R.S.; Horowitz, L.W.; Klein, S.A.; Knutson, T.R.; Kushner, P.J.; Langenhost, A.R.; Lau, N.-C.; Liang, Z.; Malyshev, S.L.; Milly, P.C.D.; Nath, M.J.; Ploshay, J.J.; Ramaswamy, V.; Schwarzkopf, M.D.; Shevliakova, E.; Sirutis, J.J.; Soden, B.J.; Stern, W.F.; Thompson, L.A.; Wilson, R.J.; Wittenberg, A.T.; Wyman, B.L.

    2004-01-01

    The configuration and performance of a new global atmosphere and land model for climate research developed at the Geophysical Fluid Dynamics Laboratory (GFDL) are presented. The atmosphere model, known as AM2, includes a new gridpoint dynamical core, a prognostic cloud scheme, and a multispecies aerosol climatology, as well as components from previous models used at GFDL. The land model, known as LM2, includes soil sensible and latent heat storage, groundwater storage, and stomatal resistance. The performance of the coupled model AM2-LM2 is evaluated with a series of prescribed sea surface temperature (SST) simulations. Particular focus is given to the model's climatology and the characteristics of interannual variability related to El Nin??o-Southern Oscillation (ENSO). One AM2-LM2 integration was perfor med according to the prescriptions of the second Atmospheric Model Intercomparison Project (AMIP II) and data were submitted to the Program for Climate Model Diagnosis and Intercomparison (PCMDI). Particular strengths of AM2-LM2, as judged by comparison to other models participating in AMIP II, include its circulation and distributions of precipitation. Prominent problems of AM2-LM2 include a cold bias to surface and tropospheric temperatures, weak tropical cyclone activity, and weak tropical intraseasonal activity associated with the Madden-Julian oscillation. An ensemble of 10 AM2-LM 2 integrations with observed SSTs for the second half of the twentieth century permits a statistically reliable assessment of the model's response to ENSO. In general, AM2-LM2 produces a realistic simulation of the anomalies in tropical precipitation and extratropical circulation that are associated with ENSO. ?? 2004 American Meteorological Society.

  2. 3-D Inhomogeous Radiative Transfer Model using a Planar-stratified Forward RT Model and Horizontal Perturbation Series

    NASA Astrophysics Data System (ADS)

    Zhang, K.; Gasiewski, A. J.

    2017-12-01

    A horizontally inhomogeneous unified microwave radiative transfer (HI-UMRT) model based upon a nonspherical hydrometeor scattering model is being developed at the University of Colorado at Boulder to facilitate forward radiative simulations for 3-dimensionally inhomogeneous clouds in severe weather. The HI-UMRT 3-D analytical solution is based on incorporating a planar-stratified 1-D UMRT algorithm within a horizontally inhomogeneous iterative perturbation scheme. Single-scattering parameters are computed using the Discrete Dipole Scattering (DDSCAT v7.3) program for hundreds of carefully selected nonspherical complex frozen hydrometeors from the NASA/GSFC DDSCAT database. The required analytic factorization symmetry of transition matrix in a normalized RT equation was analytically proved and validated numerically using the DDSCAT-based full Stokes matrix of randomly oriented hydrometeors. The HI-UMRT model thus inherits the properties of unconditional numerical stability, efficiency, and accuracy from the UMRT algorithm and provides a practical 3-D two-Stokes parameter radiance solution with Jacobian to be used within microwave retrievals and data assimilation schemes. In addition, a fast forward radar reflectivity operator with Jacobian based on DDSCAT backscatter efficiency computed for large hydrometeors is incorporated into the HI-UMRT model to provide applicability to active radar sensors. The HI-UMRT will be validated strategically at two levels: 1) intercomparison of brightness temperature (Tb) results with those of several 1-D and 3-D RT models, including UMRT, CRTM and Monte Carlo models, 2) intercomparison of Tb with observed data from combined passive and active spaceborne sensors (e.g. GPM GMI and DPR). The precise expression for determining the required number of 3-D iterations to achieve an error bound on the perturbation solution will be developed to facilitate the numerical verification of the HI-UMRT code complexity and computation performance.

  3. The AgMIP Coordinated Global and Regional Assessments (CGRA) of Climate Change Impacts on Agriculture and Food Security

    NASA Technical Reports Server (NTRS)

    Ruane, Alex; Rosenzweig, Cynthia; Elliott, Joshua; Antle, John

    2015-01-01

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) has been working since 2010 to construct a protocol-based framework enabling regional assessments (led by regional experts and modelers) that can provide consistent inputs to global economic and integrated assessment models. These global models can then relay important global-level information that drive regional decision-making and outcomes throughout an interconnected agricultural system. AgMIPs community of nearly 800 climate, crop, livestock, economics, and IT experts has improved the state-of-the-art through model intercomparisons, validation exercises, regional integrated assessments, and the launch of AgMIP programs on all six arable continents. AgMIP is now launching Coordinated Global and Regional Assessments (CGRA) of climate change impacts on agriculture and food security to link global and regional crop and economic models using a protocol-based framework. The CGRA protocols are being developed to utilize historical observations, climate projections, and RCPsSSPs from CMIP5 (and potentially CMIP6), and will examine stakeholder-driven agricultural development and adaptation scenarios to provide cutting-edge assessments of climate changes impact on agriculture and food security. These protocols will build on the foundation of established protocols from AgMIPs 30+ activities, and will emphasize the use of multiple models, scenarios, and scales to enable an accurate assessment of related uncertainties. The CGRA is also designed to provide the outputs necessary to feed into integrated assessment models (IAMs), nutrition and food security assessments, nitrogen and carbon cycle models, and additional impact-sector assessments (e.g., water resources, land-use, biomes, urban areas). This presentation will describe the current status of CGRA planning and initial prototype experiments to demonstrate key aspects of the protocols before wider implementation ahead of the IPCC Sixth Assessment Report.

  4. Pinatubo Emulation in Multiple Models (POEMs): co-ordinated experiments in the ISA-MIP model intercomparison activity component of the SPARC Stratospheric Sulphur and it's Role in Climate initiative (SSiRC)

    NASA Astrophysics Data System (ADS)

    Lee, Lindsay; Mann, Graham; Carslaw, Ken; Toohey, Matthew; Aquila, Valentina

    2016-04-01

    The World Climate Research Program's SPARC initiative has a new international activity "Stratospheric Sulphur and its Role in Climate" (SSiRC) to better understand changes in stratospheric aerosol and precursor gaseous sulphur species. One component of SSiRC involves an intercomparison "ISA-MIP" of composition-climate models that simulate the stratospheric aerosol layer interactively. Within PoEMS each modelling group will run a "perturbed physics ensemble" (PPE) of interactive stratospheric aerosol (ISA) simulations of the Pinatubo eruption, varying several uncertain parameters associated with the eruption's SO2 emissions and model processes. A powerful new technique to quantify and attribute sources of uncertainty in complex global models is described by Lee et al. (2011, ACP). The analysis uses Gaussian emulation to derive a probability density function (pdf) of predicted quantities, essentially interpolating the PPE results in multi-dimensional parameter space. Once trained on the ensemble, a Monte Carlo simulation with the fast Gaussian emulator enabling a full variance-based sensitivity analysis. The approach has already been used effectively by Carslaw et al., (2013, Nature) to quantify the uncertainty in the cloud albedo effect forcing from a 3D global aerosol-microphysics model allowing to compare the sensitivy of different predicted quantities to uncertainties in natural and anthropogenic emissions types, and structural parameters in the models. Within ISA-MIP, each group will carry out a PPE of runs, with the subsequent analysis with the emulator assessing the uncertainty in the volcanic forcings predicted by each model. In this poster presentation we will give an outline of the "PoEMS" analysis, describing the uncertain parameters to be varied and the relevance to further understanding differences identified in previous international stratospheric aerosol assessments.

  5. The AgMIP Coordinated Global and Regional Assessments (CGRA) of Climate Change Impacts on Agriculture and Food Security

    NASA Astrophysics Data System (ADS)

    Ruane, A. C.; Rosenzweig, C.; Antle, J. M.; Elliott, J. W.

    2015-12-01

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) has been working since 2010 to construct a protocol-based framework enabling regional assessments (led by regional experts and modelers) that can provide consistent inputs to global economic and integrated assessment models. These global models can then relay important global-level information that drive regional decision-making and outcomes throughout an interconnected agricultural system. AgMIP's community of nearly 800 climate, crop, livestock, economics, and IT experts has improved the state-of-the-art through model intercomparisons, validation exercises, regional integrated assessments, and the launch of AgMIP programs on all six arable continents. AgMIP is now launching Coordinated Global and Regional Assessments (CGRA) of climate change impacts on agriculture and food security to link global and regional crop and economic models using a protocol-based framework. The CGRA protocols are being developed to utilize historical observations, climate projections, and RCPs/SSPs from CMIP5 (and potentially CMIP6), and will examine stakeholder-driven agricultural development and adaptation scenarios to provide cutting-edge assessments of climate change's impact on agriculture and food security. These protocols will build on the foundation of established protocols from AgMIP's 30+ activities, and will emphasize the use of multiple models, scenarios, and scales to enable an accurate assessment of related uncertainties. The CGRA is also designed to provide the outputs necessary to feed into integrated assessment models (IAMs), nutrition and food security assessments, nitrogen and carbon cycle models, and additional impact-sector assessments (e.g., water resources, land-use, biomes, urban areas). This presentation will describe the current status of CGRA planning and initial prototype experiments to demonstrate key aspects of the protocols before wider implementation ahead of the IPCC Sixth Assessment Report.

  6. An architecture for consolidating multidimensional time-series data onto a common coordinate grid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shippert, Tim; Gaustad, Krista

    In this paper, consolidating measurement data for use by data models or in inter-comparison studies frequently requires transforming the data onto a common grid. Standard methods for interpolating multidimensional data are often not appropriate for data with non-homogenous dimensionality, and are hard to implement in a consistent manner for different datastreams. In addition, these challenges are increased when dealing with the automated procedures necessary for use with continuous, operational datastreams. In this paper we introduce a method of applying a series of one-dimensional transformations to merge data onto a common grid, examine the challenges of ensuring consistent application of datamore » consolidation methods, present a framework for addressing those challenges, and describe the implementation of such a framework for the Atmospheric Radiation Measurement (ARM) program.« less

  7. In Situ Aerosol Optical Thickness Collected by the SIMBIOS Program (1997-2000): Protocols, and and Data QC and Analysis

    NASA Technical Reports Server (NTRS)

    Fargion, Giulietta S.; Barnes, Robert; McClain, Charles

    2001-01-01

    The purpose of this technical report is to provide current documentation of the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project Office activities on in situ aerosol optical thickness (i.e., protocols, and data QC and analysis). This documentation is necessary to ensure that critical information is related to the scientific community and NASA management. This critical information includes the technical difficulties and challenges of validating and combining ocean color data from an array of independent satellite systems to form consistent and accurate global bio-optical time series products. This technical report is not meant as a substitute for scientific literature. Instead, it will provide a ready and responsive vehicle for the multitude of technical reports issued by an operational project.

  8. Uncertainty quantification of US Southwest climate from IPCC projections.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boslough, Mark Bruce Elrick

    2011-01-01

    The Intergovernmental Panel on Climate Change (IPCC) Fourth Assessment Report (AR4) made extensive use of coordinated simulations by 18 international modeling groups using a variety of coupled general circulation models (GCMs) with different numerics, algorithms, resolutions, physics models, and parameterizations. These simulations span the 20th century and provide forecasts for various carbon emissions scenarios in the 21st century. All the output from this panoply of models is made available to researchers on an archive maintained by the Program for Climate Model Diagnosis and Intercomparison (PCMDI) at LLNL. I have downloaded this data and completed the first steps toward a statisticalmore » analysis of these ensembles for the US Southwest. This constitutes the final report for a late start LDRD project. Complete analysis will be the subject of a forthcoming report.« less

  9. Crustal dynamics project observations: 1982 results and plans for 1983

    NASA Technical Reports Server (NTRS)

    Frey, H.

    1983-01-01

    The 1982 Crustal Dynamics Project observations by fixed and mobile SLR and VLBI systems are reviewed. Plate motion measurements between North America and Europe were conducted by both techniques and SLR measurements were also made between North America, the Pacific, Australia and South American plates. Regional deformation measurements by VLBI and SLR systems were restricted to the western United States in 1982, including a number of important intercomparison baseline measured by both techniques. In 1983 the observing program grows significantly, with new SLR systems in Mexico, Easter Island, the Pacific and Italy. New VLBI systems will include a dedicated VLBI site at Weltzell, in Germany. Two highly mobile SLR and two highly mobile VLBI systems will greatly increase the regional deformation measurements in California and through the Basin and Range, where more than 25 sites will be occupied in 1983.

  10. An architecture for consolidating multidimensional time-series data onto a common coordinate grid

    DOE PAGES

    Shippert, Tim; Gaustad, Krista

    2016-12-16

    In this paper, consolidating measurement data for use by data models or in inter-comparison studies frequently requires transforming the data onto a common grid. Standard methods for interpolating multidimensional data are often not appropriate for data with non-homogenous dimensionality, and are hard to implement in a consistent manner for different datastreams. In addition, these challenges are increased when dealing with the automated procedures necessary for use with continuous, operational datastreams. In this paper we introduce a method of applying a series of one-dimensional transformations to merge data onto a common grid, examine the challenges of ensuring consistent application of datamore » consolidation methods, present a framework for addressing those challenges, and describe the implementation of such a framework for the Atmospheric Radiation Measurement (ARM) program.« less

  11. Momentum and Energy Assessments with NASA and Other Model and Data Assimilation Systems

    NASA Technical Reports Server (NTRS)

    Salstein, David; Nelson, Peter; Hu, Wen-Jie

    2001-01-01

    Support from the NASA Global Modeling and Analysis Program has been used for the following research objectives: 1) the study of aspects of dynamics of torques and angular momentum based on the Goddard GEOS and other analyses; 2) the study of how models participating in the second Atmospheric Model Intercomparison Project (AMIP-2) have success in simulating certain large-scale quantities; 3) the study of the energetics and momentum cycle from certain runs from the Goddard Laboratory for Atmospheres and other models as well; 4) the assessment of changes in diabatic heating and related energetics in the community climate model (CCM3); 5) the analysis of modes of climate of the atmosphere, especially the Arctic and North Atlantic Oscillations. Further information on these endeavors will be provided in published works and the Final Report of the project.

  12. High LET, passive space radiation dosimetry and spectrometry

    NASA Technical Reports Server (NTRS)

    Benton, E. V.; Frank, A. L.; Benton, E. R.; Keegan, R. P.; Frigo, L. A.; Sanner, D.; Rowe, V.

    1995-01-01

    The development of high linear energy transfer (LET), passive radiation dosimetry and spectrometry is needed for the purpose of accurate determination of equivalent doses and assessment of health risks to astronauts on long duration missions. Progress in the following research areas is summerized: intercomparisons of cosmic ray equivalent dose and LET spectra measurements between STS missions and between astronauts; increases LET spectra measurement accuracy with ATAS; space radiation measurements for intercomparisons of passive (PNTD, TLD, TRND, Emulsion) and active (TEPC, RME-111) dosimeters; interaction of cosmic ray particles with nuclei in matter; radiation measurements after long duration space exposures; ground based dosimeter calibrations; neutron detector calibrations; radiation measurements on Soviet/Russian spacecraft; space radiation measurements under thin shielding; and space radiation.

  13. Test Bed Doppler Wind Lidar and Intercomparison Facility At NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Kavaya, Michael J.; Koch, Grady J.; Petros, Mulugeta; Barnes, Bruce W.; Beyon, Jeffrey; Amzajerdian, Farzin; Yu, Ji-Rong; Singh, Upendra N.

    2004-01-01

    State of the art 2-micron lasers and other lidar components under development by NASA are being demonstrated and validated in a mobile test bed Doppler wind lidar. A lidar intercomparison facility has been developed to ensure parallel alignment of up to 4 Doppler lidar systems while measuring wind. Investigations of the new components; their operation in a complete system; systematic and random errors; the hybrid (joint coherent and direct detection) approach to global wind measurement; and atmospheric wind behavior are planned. Future uses of the VALIDAR (VALIDation LIDAR) mobile lidar may include comparison with the data from an airborne Doppler wind lidar in preparation for validation by the airborne system of an earth orbiting Doppler wind lidar sensor.

  14. Intercomparison of analytical methods for arsenic speciation in human urine.

    PubMed Central

    Crecelius, E; Yager, J

    1997-01-01

    An intercomparison exercise was conducted for the quantification of arsenic species in spiked human urine. The primary objective of the exercise was to determine the variance among laboratories in the analysis of arsenic species such as inorganic As (As+3 and As+5), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA). Laboratories that participated had previous experience with arsenic speciation analysis. The results of this interlaboratory comparison are encouraging. There is relatively good agreement on the concentrations of these arsenic species in urine at concentrations that are relevant to research on the metabolism of arsenic in humans and other mammals. Both the accuracy and precision are relatively poor for arsenic concentrations of less than about 5 micrograms/l. PMID:9288500

  15. Catalytic Bioscavengers Human Butyrylcholinesterase and Paraoxonase Sequestered to the Center for CNS

    DTIC Science & Technology

    2010-04-01

    of radiolabeling fusion proteins without the denaturing effects coincident with oxidative radio-iodination associated with the chloramine T method...organ PS product = [(%ID/g)/AUC]*1000 Reportable Outcomes (1) The plasma concentration decay curve for AGT-185 is shown in Figure 1. The % of...injected dose (ID)/mL decreases rapidly in plasma following IV injection. This plasma decay curve was fit to the bi-exponential equation described above

  16. Nuclear imaging and radiation therapy in canine and feline thyroid disease.

    PubMed

    Feeney, Daniel A; Anderson, Kari L

    2007-07-01

    The indications, techniques, and expectations for radionuclide diagnostic studies on canine and feline thyroid glands are presented. In addition, the considerations surrounding radioiodine or external beam radiotherapy for benign and malignant thyroid disease are reviewed. The intent of this article is to familiarize primary care veterinarians with the utility of and outcome of the ionizing radiation-based diagnostic and therapeutic techniques for assessing and treating canine and feline thyroid disease.

  17. The centrality of meta-programming in the ES-DOC eco-system

    NASA Astrophysics Data System (ADS)

    Greenslade, Mark

    2017-04-01

    The Earth System Documentation (ES-DOC) project is an international effort aiming to deliver a robust earth system model inter-comparison project documentation infrastructure. Such infrastructure both simplifies & standardizes the process of documenting (in detail) projects, experiments, models, forcings & simulations. In support of CMIP6, ES-DOC has upgraded its eco-system of tools, web-services & web-sites. The upgrade consolidates the existing infrastructure (built for CMIP5) and extends it with the introduction of new capabilities. The strategic focus of the upgrade is improvements in the documentation experience and broadening the range of scientific use-cases that the archived documentation may help deliver. Whether it is highlighting dataset errors, exploring experimental protocols, comparing forcings across ensemble runs, understanding MIP objectives, reviewing citations, exploring component properties of configured models, visualising inter-model relationships, scientists involved in CMIP6 will find the ES-DOC infrastructure helpful. This presentation underlines the centrality of meta-programming within the ES-DOC eco-system. We will demonstrate how agility is greatly enhanced by taking a meta-programming approach to representing data models and controlled vocabularies. Such an approach nicely decouples representations from encodings. Meta-models will be presented along with the associated tooling chain that forward engineers artefacts as diverse as: class hierarchies, IPython notebooks, mindmaps, configuration files, OWL & SKOS documents, spreadsheets …etc.

  18. Multicentre validation of IMRT pre-treatment verification: comparison of in-house and external audit.

    PubMed

    Jornet, Núria; Carrasco, Pablo; Beltrán, Mercè; Calvo, Juan Francisco; Escudé, Lluís; Hernández, Victor; Quera, Jaume; Sáez, Jordi

    2014-09-01

    We performed a multicentre intercomparison of IMRT optimisation and dose planning and IMRT pre-treatment verification methods and results. The aims were to check consistency between dose plans and to validate whether in-house pre-treatment verification results agreed with those of an external audit. Participating centres used two mock cases (prostate and head and neck) for the intercomparison and audit. Compliance to dosimetric goals and total number of MU per plan were collected. A simple quality index to compare the different plans was proposed. We compared gamma index pass rates using the centre's equipment and methodology to those of an external audit. While for the prostate case, all centres fulfilled the dosimetric goals and plan quality was homogeneous, that was not the case for the head and neck case. The number of MU did not correlate with the plan quality index. Pre-treatment verifications results of the external audit did not agree with those of the in-house measurements for two centres: being within tolerance for in-house measurements and unacceptable for the audit or the other way round. Although all plans fulfilled dosimetric constraints, plan quality is highly dependent on the planner expertise. External audits are an excellent tool to detect errors in IMRT implementation and cannot be replaced by intercomparison using results obtained by centres. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Introduction to the SPARC Reanalysis Intercomparison Project (S-RIP) and overview of the reanalysis systems

    NASA Astrophysics Data System (ADS)

    Fujiwara, Masatomo; Wright, Jonathon S.; Manney, Gloria L.; Gray, Lesley J.; Anstey, James; Birner, Thomas; Davis, Sean; Gerber, Edwin P.; Harvey, V. Lynn; Hegglin, Michaela I.; Homeyer, Cameron R.; Knox, John A.; Krüger, Kirstin; Lambert, Alyn; Long, Craig S.; Martineau, Patrick; Molod, Andrea; Monge-Sanz, Beatriz M.; Santee, Michelle L.; Tegtmeier, Susann; Chabrillat, Simon; Tan, David G. H.; Jackson, David R.; Polavarapu, Saroja; Compo, Gilbert P.; Dragani, Rossana; Ebisuzaki, Wesley; Harada, Yayoi; Kobayashi, Chiaki; McCarty, Will; Onogi, Kazutoshi; Pawson, Steven; Simmons, Adrian; Wargan, Krzysztof; Whitaker, Jeffrey S.; Zou, Cheng-Zhi

    2017-01-01

    The climate research community uses atmospheric reanalysis data sets to understand a wide range of processes and variability in the atmosphere, yet different reanalyses may give very different results for the same diagnostics. The Stratosphere-troposphere Processes And their Role in Climate (SPARC) Reanalysis Intercomparison Project (S-RIP) is a coordinated activity to compare reanalysis data sets using a variety of key diagnostics. The objectives of this project are to identify differences among reanalyses and understand their underlying causes, to provide guidance on appropriate usage of various reanalysis products in scientific studies, particularly those of relevance to SPARC, and to contribute to future improvements in the reanalysis products by establishing collaborative links between reanalysis centres and data users. The project focuses predominantly on differences among reanalyses, although studies that include operational analyses and studies comparing reanalyses with observations are also included when appropriate. The emphasis is on diagnostics of the upper troposphere, stratosphere, and lower mesosphere. This paper summarizes the motivation and goals of the S-RIP activity and extensively reviews key technical aspects of the reanalysis data sets that are the focus of this activity. The special issue The SPARC Reanalysis Intercomparison Project (S-RIP) in this journal serves to collect research with relevance to the S-RIP in preparation for the publication of the planned two (interim and full) S-RIP reports.

  20. The CMIP6 Sea-Ice Model Intercomparison Project (SIMIP): Understanding sea ice through climate-model simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Notz, Dirk; Jahn, Alexandra; Holland, Marika

    A better understanding of the role of sea ice for the changing climate of our planet is the central aim of the diagnostic Coupled Model Intercomparison Project 6 (CMIP6)-endorsed Sea-Ice Model Intercomparison Project (SIMIP). To reach this aim, SIMIP requests sea-ice-related variables from climate-model simulations that allow for a better understanding and, ultimately, improvement of biases and errors in sea-ice simulations with large-scale climate models. This then allows us to better understand to what degree CMIP6 model simulations relate to reality, thus improving our confidence in answering sea-ice-related questions based on these simulations. Furthermore, the SIMIP protocol provides a standardmore » for sea-ice model output that will streamline and hence simplify the analysis of the simulated sea-ice evolution in research projects independent of CMIP. To reach its aims, SIMIP provides a structured list of model output that allows for an examination of the three main budgets that govern the evolution of sea ice, namely the heat budget, the momentum budget, and the mass budget. Furthermore, we explain the aims of SIMIP in more detail and outline how its design allows us to answer some of the most pressing questions that sea ice still poses to the international climate-research community.« less

Top