  1. Radioisotope x-ray fluorescence analysis of ancient pottery from Tel Kouzama site in Damascus, Syria.

    PubMed

    Bakraji, Elias Hanna; Romeié, Mouhammad; Issa, Haissam

    2006-01-01

    The radioisotope X-ray fluorescence method has been utilized in the analysis of thirty nine archaeological pottery fragment samples from Tel Kouzama site, Damascus city, Syria. The samples were irradiated by a 109Cd radioisotope source (-9 10(8) Bq) for 1000 s. 17 chemical elements were determined. These elemental concentrations have been processed using two multivariate statistical methods, cluster and factor analysis in order to determine similarities and correlation between the various samples. Factor analysis confirms that samples were correctly classified by cluster analysis. These two methods suggest that samples can be considered to be manufactured using four different sources of raw material.

  2. Trace element profiles in murine Lewis lung carcinoma by radioisotope-induced X-ray fluorescence.

    PubMed Central

    Frank, A. S.; Schauble, M. K.; Preiss, I. L.

    1986-01-01

    Trace element profiles of various body tissues and tumor were established during growth of the Lewis lung tumor (LLT) with the use of radioisotope-induced X-ray fluorescence (RIXRF) analysis. The LLT, a highly malignant experimental murine tumor, resembles its human counterpart, has a well-defined life cycle, and kills its host in 30 days. When compared with normal controls, Zn, Br, and Rb levels in lung, liver, and skeletal muscle and Zn and Sr levels in bone from tumor-bearing mice exhibited large fluctuations at critical points in the tumor life cycle. In addition, the 24-day primary tumor trace element profile resembled that of its tissue of origin, normal lung, and was quite different from other normal tissues studied. These findings indicate that trace element profiles may help in the diagnosis, staging, and monitoring of disease. RIXRF is an excellent technique for this purpose because it is sensitive and relatively nondestructive of samples and has multielement capabilities. Images Figure 1 p423-a PMID:3953767

  3. Determination of trace elements in bee honey, pollen and tissue by total reflection and radioisotope X-ray fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Kump, P.; Nečemer, M.; Šnajder, J.

    1996-04-01

    Multielemental determinations in samples of various types of bee honey, pollen and bee tissue have been carried out using total reflection X-ray fluorescence spectrometry (TXRF) and radioisotope excited X-ray fluorescence spectrometry (XRF). The objective was to establish whether the elemental content of bee honey, in particular, correlates with any useful information about the environment, variety of honey, etc. An attempt has also been made to determine the X-ray techniques' ability to compete with atomic absorption spectrometry (AAS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES), with regard to elemental sensitivity, accuracy, sample preparation procedures, and in particular, economic performance, which is very important in selecting an appropriate technique for the analysis of large numbers of samples. The results confirm the advantages of the TXRF method for trace element analysis, but only when utilising monochromatic excitation and selecting a proper sample preparation procedure. The radioisotope XRF technique, which does not require any sample preparation, is still very competitive in analysis of elements with concentrations above a few ten ppm. Preliminary results also confirm some correlations between the elemental content of honey and the status of the environment, and encourage further work in this direction

  4. Radioisotope X-ray fluorescence and neutron activation analyses of the trace element concentrations of the rainbow trout

    NASA Astrophysics Data System (ADS)

    Akyuz, T.; Bassari, A.; Bolcal, C.; Sener, E.; Yildiz, M.; Kucer, R.; Kaplan, Z.; Dogan, G.; Akyuz, S.

    1999-01-01

    The muscles and livers of the ten rainbow trouts ( Oncorhynchus mykiss; N, 1752) obtained from Sapanca, Aquaculture Facility of Aquatic Products Faculty, The University of Istanbul (Turkey), have been analysed quantitatively for some minor elements using the radioisotope energy dispersive X-ray fluorescence (EDXRF) and neutron activation analysis (NAA) methods. It was found that samples contain Na, K, Ca, Sc, Cs, Fe, Co, Cu, Zn, Se, Br, Rb, Sr, Au, La and Ce in different amounts. Comparison of the results with those of reference river fish samples indicated that agricultural rainbow trout samples from Sapanca region have higher Fe level.

  5. Nondestructive determination of lead, cadmium, tin, antimony, and barium in ceramic glazes by radioisotope X-ray fluorescence spectrometry.

    PubMed

    Anderson, D L; Cunningham, W C

    1996-01-01

    Quantitation capabilities of radioisotope X-ray fluorescence spectrometry (RXRFS) for determining lead, cadmium, tin, antimony, and barium in ceramic glazes were investigated. Twenty-one air-dried glazes and 85 fired glazes on test tiles were analyzed by using 109Cd and 57Co excitation sources. Accurate Pb determinations, with limits of detection (LODs) of about 0.3 mg/cm2 for 5 min counting times, were achieved by using the 75 keV K alpha 1 X-ray photopeak and a Pb foil calibration procedure. Cd, Sn, Sb, and Ba concentrations were determined with LODs from about 0.5 to 1.5 mg/cm2. For Pb and Ba, results obtained by using absorption corrections based only on element concentrations determined by RXRFS and an iterative approach led to analytical biases of < or = 4% relative to results obtained by using corrections based on known total element compositions. Biases were more severe for Cd, Sn, and Sb because lower X-ray energies were involved and sensitivities varied as a function of matrix Pb content. Pb concentrations were above LODs (1.3-40 mg/cm2) in 39 of 47 fired "food-safe" glazes and in 33 of the other 38 fired glazes (0.4-39 mg/cm2).

  6. Nondestructive determination of lead, cadmium, tin, antimony, and barium in ceramic glazes by radioisotope X-ray fluorescence spectrometry

    SciTech Connect

    Anderson, D.L.; Cunningham, W.C.

    1996-09-01

    Quantitation capabilities of radioisotope X-ray fluorescence spectrometry (RXRFS) for determining lead, cadmium, tin, antimony, and barium in ceramic glazes were investigated. Twenty-one air-dried glazes and 85 fired glazes on test tiles were analyzed by using {sup 109}Cd and {sup 57}Co excitation sources. Accurate Pb determinations, with limits of detection (LODs) of about 0.3 mg/cm{sup 2} for 5 min counting times, were achieved by using the 75 keV {Kappa}{sub {alpha}}{sub 1} X-ray photopeak and a Pb foil calibration procedure. Cd, Sn, Sb, and Ba concentrations were determined with LODs from about 0.5 to 1.5 mg/cm{sup 2}. For Pb and Ba, results obtained by using absorption corrections based only on element concentrations determined by RXRFS and an iterative approach led to analytical biases of {le}4% relative to results obtained by using corrections based on known total element compositions. Biases were more severe for Cd, Sn, and Sb because lower X-ray energies were involved and sensitivities varied as a function of matrix Pb content. Pb concentrations were above LODs (1.3-40 mg/cm{sup 2}) in 39 of 47 fired {open_quotes}food-safe{close_quotes} glazes and in 33 of the other 38 fired glazes (0.4-39 mg/cm{sup 2}). 15 refs., 9 figs., 9 tabs.

  7. Student X-Ray Fluorescence Experiments

    ERIC Educational Resources Information Center

    Fetzer, Homer D.; And Others

    1975-01-01

    Describes the experimental arrangement for x-ray analysis of samples which involves the following: the radioisotopic x-ray disk source; a student-built fluorescence chamber; the energy dispersive x-ray detector, linear amplifier and bias supply; and a multichannel pulse height analyzer. (GS)

  8. Apollo 15 X-ray fluorescence experiment

    NASA Technical Reports Server (NTRS)

    Adler, I.; Trombka, J.; Gerard, J.; Schmadebeck, R.; Lowman, P.; Blodgett, H.; Yin, L.; Eller, E.; Lamothe, R.; Gorenstein, P.

    1971-01-01

    The X-ray fluorescence spectrometer, carried in the SIM bay of the command service module was employed principally for compositional mapping of the lunar surface while in lunar orbit, and secondarily, for X-ray astronomical observations during the trans-earth coast. The lunar surface measurements involved observations of the intensity and characteristics energy distribution of the secondary or fluorescent X-rays produced by the interaction of solar X-rays with the lunar surface. The astronomical observations consisted of relatively long periods of measurements of X-rays from pre-selected galactic sources such as Cyg-X-1 and Sco X-1 as well as from the galactic poles.

  9. The Mapping X-Ray Fluorescence Spectrometer (MAPX)

    NASA Technical Reports Server (NTRS)

    Blake, David; Sarrazin, Philippe; Bristow, Thomas; Downs, Robert; Gailhanou, Marc; Marchis, Franck; Ming, Douglas; Morris, Richard; Sole, Vincente Armando; Thompson, Kathleen; Walter, Philippe; Wilson, Michael; Yen, Albert; Webb, Samuel

    2016-01-01

    MapX will provide elemental imaging at =100 micron spatial resolution over 2.5 X 2.5 centimeter areas, yielding elemental chemistry at or below the scale length where many relict physical, chemical, and biological features can be imaged and interpreted in ancient rocks. MapX is a full-frame spectroscopic imager positioned on soil or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample surface with X-rays or alpha-particles / gamma rays, resulting in sample X-ray Fluorescence (XRF). Fluoresced X-rays pass through an X-ray lens (X-ray µ-Pore Optic, "MPO") that projects a spatially resolved image of the X-rays onto a CCD. The CCD is operated in single photon counting mode so that the positions and energies of individual photons are retained. In a single analysis, several thousand frames are stored and processed. A MapX experiment provides elemental maps having a spatial resolution of =100 micron and quantitative XRF spectra from Regions of Interest (ROI) 2 centimers = x = 100 micron. ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. The MapX geometry is being refined with ray-tracing simulations and with synchrotron experiments at SLAC. Source requirements are being determined through Monte Carlo modeling and experiment using XMIMSIM [1], GEANT4 [2] and PyMca [3] and a dedicated XRF test fixture. A flow-down of requirements for both tube and radioisotope sources is being developed from these experiments. In addition to Mars lander and rover missions, MapX could be used for landed science on other airless bodies (Phobos/Deimos, Comet nucleus, asteroids, the Earth's moon, and the icy satellites of the outer planets, including Europa.

  10. Application of the radioisotope excited X-ray fluorescence technique in charge optimization during thermite smelting of Fe-Ni, Fe-cr, and Fe-Ti alloys

    SciTech Connect

    Sharma, I.G.; Joseph, D.; Lal, M.; Bose, D.K.

    1995-10-01

    A wide range of ferroalloys are used to facilitate the addition of different alloying elements to molten steel. High-carbon ferroalloys are produced on a tonnage basis by carbothermic smelting in an electric furnace, and an aluminothermic route is generally adopted for small scale production of low-carbon varieties. The physicochemical principles of carbothermy and aluminothermy have been well documented in the literature. However, limited technical data are reported on the production of individual ferroalloys of low-carbon varieties from their selected resources. The authors demonstrate her the application of an energy dispersive X-ray fluorescence (EDXRF) technique in meeting the analytical requirements of a thermite smelting campaign, carried out with the aim of preparing low-carbon-low-nitrogen Fe-Ni, Fe-Cr, and Fe-Ti alloys from indigenously available nickel bearing spent catalyst, mineral chromite, and ilmenite/rutile, respectively. They have chosen the EDXRF technique to meet the analytical requirements because of its capability to analyze samples of ore, minerals, a metal, and alloys in different forms, such as powder, sponge, as-smelted, or as-cast, to obtain rapid multielement analyses with ease. Rapid analyses of thermite feed and product by this technique have aided in the appropriate alterations of the charge constitutents to obtain optimum charge consumption.

  11. Filtered fluorescer x-ray detector

    SciTech Connect

    Bruns, H.C.; Emig, J.A.; Thoe, R.S.; Springer, P.T.; Hernandez, J.A.

    1995-04-01

    Recently, an instrument capable of measuring x-rays between 8 and 90 keV was conceived to help understand conditions pertaining to pulsed power research. This resulted in the development of a versatile device that would incrementally detect x-rays emitted at predetermined energy bands over this range. To accomplish this, an array of well characterized filter-fluorescer combinations were produced which would allow fluoresced x-rays to be observed by time resolved electro-optical devices. As many as sixteen channels could be utilized with each channel having a corresponding background channel. Upon completion of the device, a three week series of experiments was then successfully carried out.

  12. Surface-Enhanced X-Ray Fluorescence

    NASA Technical Reports Server (NTRS)

    Anderson, Mark

    2010-01-01

    Surface-enhanced x-ray fluorescence (SEn-XRF) spectroscopy is a form of surface- enhanced spectroscopy that was conceived as a means of obtaining greater sensitivity in x-ray fluorescence (XRF) spectroscopy. As such, SEn-XRF spectroscopy joins the ranks of such other, longer-wavelength surface-enhanced spectroscopies as those based on surface-enhanced Raman scattering (SERS), surface-enhanced resonance Raman scattering (SERRS), and surfaceenhanced infrared Raman absorption (SEIRA), which have been described in previous NASA Tech Briefs articles. XRF spectroscopy has been used in analytical chemistry for determining the elemental compositions of small samples. XRF spectroscopy is rapid and quantitative and has been applied to a variety of metal and mineralogical samples. The main drawback of XRF spectroscopy as practiced heretofore is that sensitivity has not been as high as required for some applications. In SEn-XRF as in the other surface-enhanced spectroscopies, one exploits several interacting near-field phenomena, occurring on nanotextured surfaces, that give rise to local concentrations of incident far-field illumination. In this case, the far-field illumination comes from an x-ray source. Depending on the chemical composition and the geometry of a given nanotextured surface, these phenomena could include the lightning-rod effect (concentration of electric fields at the sharpest points on needlelike surface features), surface plasmon resonances, and grazing incidence geometric effects. In the far field, the observable effect of these phenomena is an increase in the intensity of the spectrum of interest - in this case, the x-ray fluorescence spectrum of chemical elements of interest that may be present within a surface layer at distances no more than a few nanometers from the surface.

  13. Determination of Barium and selected rare-earth elements in geological materials employing a HpGe detector by radioisotope excited x-ray fluorescence

    SciTech Connect

    LaBrecque, J.J.; Preiss, I.L.

    1984-01-01

    The laterite material (geological) from Cerro Impacto was first studied by air radiometric techniques in the 1970's and was found to have an abnormally high radioactive background. Further studies showed this deposit to be rich in thorium, columbium, barium and rare-earth elements (mostly La, Ce, Pr and Nd). A similar work has been reported for the analysis of Brazil's lateritic material from Morro do Ferro to determine elemental compositions (including barium and rare-earth elements) and its relationship to the mobilization of thorium from the deposit using a Co-57 radioisotope source. The objective of this work was to develop an analytical method to determine barium and rare-earth element present in Venezuelan lateritic material from Cerro Impacto. We have employed a method before, employing a Si(Li) detector, but due to the low detection efficiencies in the rare-earth K-lines region (about 30 KeV - 40 KeV), we have decided to study the improvement in sensitivities and detection limits using an hyperpure germanium detector.

  14. Laser-based X-ray and electron source for X-ray fluorescence studies

    NASA Astrophysics Data System (ADS)

    Valle Brozas, F.; Crego, A.; Roso, L.; Peralta Conde, A.

    2016-08-01

    In this work, we present a modification to conventional X-rays fluorescence using electrons as excitation source and compare it with the traditional X-ray excitation for the study of pigments. For this purpose, we have constructed a laser-based source capable to produce X-rays as well as electrons. Because of the large penetration depth of X-rays, the collected fluorescence signal is a combination of several material layers of the artwork under study. However, electrons are stopped in the first layers, allowing a more superficial analysis. We show that the combination of both excitation sources can provide extremely valuable information about the structure of the artwork.

  15. Archaeometry Using X-Ray Fluorescence

    NASA Astrophysics Data System (ADS)

    Olvera, Juan; Bixler, David

    2010-03-01

    I am currently using X-Ray Fluorescence (XRF) for analyzing archeological and mineralogical samples and determining their elemental constituents. Although XRF may be applied to many different fields, I am using this technique in the field of archaeometry. For example, with XRF, I can determine what elements make up a chert arrowhead, and, with a database of such information, determine the likely origin of a particular artifact. I am using Amptek's ADMCA software, detector, X-ray source, and electronics to collect data spectra. I will present preliminary data on chert samples (worked and unworked) that have been collected from various nearby sites. This allows me to build up a database of the elemental fingerprint of chert from these regions. Then, chert artifacts can be examined and their ``fingerprints'' compared to the database. With a completely mapped out database we may be able to determine interactions between different groups of people. No conclusions can be made at this time because the database is currently being built.

  16. X-ray microprobe for micro x-ray fluorescence and absorption spectroscopies at GSECARS

    NASA Astrophysics Data System (ADS)

    Newville, M.; Sutton, S.; Rivers, M.

    2002-12-01

    The hard x-ray microprobe for x-ray fluorescence and absorption spectroscopy at GeoSoilEnviroCARS is presented. Using focused synchrotron radiation from an undulator beamline at the Advanced Photon Source at Argonne National Lab, the x-ray microprobe provides bright, monochromatic x-rays with typical spot sizes down to 1x1 μm for x-ray fluorescence and absorption spectroscopies. Quantitative x-ray fluorescence (XRF) analysis gives precise elemental composition and correlations, while x-ray absorption spectroscopy (XAS) gives the chemical state and local atomic coordination for a selected atomic species. These two techniques can be used in conjunction with one another on a wide range of samples, including minerals, glasses, fluid inclusions, soils, sediments, and plant tissue. This x-ray microprobe is part of the GeoSoilEnviroCARS user facility, available for use in all areas geological, soil, and environmental sciences, and selected examples from these fields will be given.

  17. Coded Aperture Imaging for Fluorescent X-rays-Biomedical Applications

    SciTech Connect

    Haboub, Abdel; MacDowell, Alastair; Marchesini, Stefano; Parkinson, Dilworth

    2013-06-01

    Employing a coded aperture pattern in front of a charge couple device pixilated detector (CCD) allows for imaging of fluorescent x-rays (6-25KeV) being emitted from samples irradiated with x-rays. Coded apertures encode the angular direction of x-rays and allow for a large Numerical Aperture x- ray imaging system. The algorithm to develop the self-supported coded aperture pattern of the Non Two Holes Touching (NTHT) pattern was developed. The algorithms to reconstruct the x-ray image from the encoded pattern recorded were developed by means of modeling and confirmed by experiments. Samples were irradiated by monochromatic synchrotron x-ray radiation, and fluorescent x-rays from several different test metal samples were imaged through the newly developed coded aperture imaging system. By choice of the exciting energy the different metals were speciated.

  18. X-ray fluorescence in investigations of archaeological finds

    NASA Astrophysics Data System (ADS)

    Čechák, T.; Hložek, M.; Musílek, L.; Trojek, T.

    2007-10-01

    X-ray fluorescence can be successfully used for analysing the elemental composition of the superficial layers of a measured object, especially for investigating surface coatings, deposits of adventitious materials on the surface, etc. An energy dispersive version of X-ray fluorescence analysis is used in our investigations for analysing various historic objects, art works and archaeological finds. Examples of the application of X-ray fluorescence to various archaeological finds from excavations in the Czech Republic are presented - shards of ancient glazed ceramics, moulds for casting metal products, the remains of a human finger with traces of brass, probably from a ring, etc.

  19. X-ray fluorescence and X-ray transmission microtomography imaging system

    NASA Astrophysics Data System (ADS)

    Pereira, Gabriela R.; Rocha, Henrique S.; Anjos, Marcelino J.; Faria, Paulo; Pérez, Carlos A.; Lopes, Ricardo T.

    2007-10-01

    An X-ray Transmission Microtomography (CT) system combined with an X-ray Fluorescence Microtomography (XRFCT) system was implemented in the Brazilian Synchrotron Light Source (LNLS), Campinas, Brazil. The main aim of this work is to determine the elemental and absorption distribution map in breast tissue samples. The experiments were performed at the X-Ray Fluorescence beamline (D09B-XRF) of the Brazilian Synchrotron Light Source (LNLS), Campinas, Brazil. A quasi-monochromatic beam produced by a multilayer monochromator was used as an incident beam. The fluorescence photons were acquired with an energy dispersive HPGe detector (CANBERRA Industries Inc.) placed at 90∘ to the incident beam, while transmitted photons were detected with a fast Na(Tl) scintillation counter (CYBERSTAR Oxford Danfysik) placed behind the sample in the beam direction. All the tomographic images were reconstructed using a filtered-back projection algorithm.

  20. Coded aperture imaging for fluorescent x-rays

    SciTech Connect

    Haboub, A.; MacDowell, A. A.; Marchesini, S.; Parkinson, D. Y.

    2014-06-15

    We employ a coded aperture pattern in front of a pixilated charge couple device detector to image fluorescent x-rays (6–25 KeV) from samples irradiated with synchrotron radiation. Coded apertures encode the angular direction of x-rays, and given a known source plane, allow for a large numerical aperture x-ray imaging system. The algorithm to develop and fabricate the free standing No-Two-Holes-Touching aperture pattern was developed. The algorithms to reconstruct the x-ray image from the recorded encoded pattern were developed by means of a ray tracing technique and confirmed by experiments on standard samples.

  1. Synchrotron x-ray fluorescence and extended x-ray absorption fine structure analysis

    SciTech Connect

    Chen, J.R.; Gordon, B.M.; Hanson, A.L.; Jones, K.W.; Kraner, H.W.; Chao, E.C.T.; Minkin, J.A.

    1984-01-01

    The advent of dedicated synchrotron radiation sources has led to a significant increase in activity in many areas of science dealing with the interaction of x-rays with matter. Synchrotron radiation provides intense, linearly polarized, naturally collimated, continuously tunable photon beams, which are used to determine not only the elemental composition of a complex, polyatomic, dilute material but also the chemical form of the elements with improved accuracy. Examples of the application of synchrotron radiation include experiments in synchrotron x-ray fluorescence (SXRF) analysis and extended x-ray absorption fine structure (EXAFS) analysis. New synchrotron radiation x-ray microprobes for elemental analysis in the parts per billion range are under construction at several laboratories. 76 references, 24 figures.

  2. Recoil splitting of x-ray-induced optical fluorescence

    SciTech Connect

    Gavrilyuk, S.; Aagren, H.; Gel'mukhanov, F.; Sun, Y.-P.; Levin, S.

    2010-03-15

    We show that the anisotropy of the recoil velocity distribution of x-ray-ionized atoms or molecules leads to observable splittings in subsequent optical fluorescence or absorption when the polarization vector of the x rays is parallel to the momentum of the fluorescent photons. The order of the magnitude of the recoil-induced splitting is about 10 {mu}eV, which can be observed using Fourier or laser-absorption spectroscopic techniques.

  3. [The X-Ray Fluorescence Spectrometer Based on Pyroelectric Effect].

    PubMed

    Dong, Yi-fan; Fan, Rui-rui; Guo, Dong-ya; Zhang, Chun-lei; Gao, Min; Wang, Jin-zhou; Liu, Ya-qing; Zhou, Da-wei; Wang, Huan-yu

    2016-02-01

    Pyroelectric X-ray generator is implemented, and an X-ray fluorescence spectrometer is accomplished by combining the pyroelectric X-ray generator with a high energy resolution silicon drift detector. Firstly, the parameters of the X-ray generator are decided by analyzing and calculating the influence of the thickness of the pyroelectriccrystal and the thickness of the target on emitted X-ray. Secondly, the emitted X-ray is measured. The energy of emitted X-ray is from 1 to 27 keV, containing the characteristic X-ray of Cu and Ta, and the max counting rate is more than 3 000 per second. The measurement also proves that the detector of the spectrometer has a high energy resolution which the FWMH is 210 eV at 8. 05 keV. Lastly, samples of Fe, Ti, Cr and high-Ti basalt are analyzed using the spectrometer, and the results are agreed with the elements of the samples. It shows that the spectrometer consisting of a pyroelectric X-ray generator and a silicon drift detector is effective for element analysis. Additionally, because each part of the spectrometer has a small volume, it can be easily modified to a portable one which is suitable for non-destructive, on-site and quick element analysis. PMID:27209767

  4. [The X-Ray Fluorescence Spectrometer Based on Pyroelectric Effect].

    PubMed

    Dong, Yi-fan; Fan, Rui-rui; Guo, Dong-ya; Zhang, Chun-lei; Gao, Min; Wang, Jin-zhou; Liu, Ya-qing; Zhou, Da-wei; Wang, Huan-yu

    2016-02-01

    Pyroelectric X-ray generator is implemented, and an X-ray fluorescence spectrometer is accomplished by combining the pyroelectric X-ray generator with a high energy resolution silicon drift detector. Firstly, the parameters of the X-ray generator are decided by analyzing and calculating the influence of the thickness of the pyroelectriccrystal and the thickness of the target on emitted X-ray. Secondly, the emitted X-ray is measured. The energy of emitted X-ray is from 1 to 27 keV, containing the characteristic X-ray of Cu and Ta, and the max counting rate is more than 3 000 per second. The measurement also proves that the detector of the spectrometer has a high energy resolution which the FWMH is 210 eV at 8. 05 keV. Lastly, samples of Fe, Ti, Cr and high-Ti basalt are analyzed using the spectrometer, and the results are agreed with the elements of the samples. It shows that the spectrometer consisting of a pyroelectric X-ray generator and a silicon drift detector is effective for element analysis. Additionally, because each part of the spectrometer has a small volume, it can be easily modified to a portable one which is suitable for non-destructive, on-site and quick element analysis.

  5. X-ray fluorescence computed tomography system for biomedical imaging

    NASA Astrophysics Data System (ADS)

    Enomoto, Toshiyuki; Sato, Eiichi; Abderyim, Purkhet; Matsukiyo, Hiroshi; Osawa, Akihiro; Watanabe, Manabu; Nagao, Jiro; Nomiya, Seiichiro; Hitomi, Keitro; Izumisawa, Mitsuru; Ogawa, Akira; Sato, Shigehiro

    2008-08-01

    An x-ray fluorescence (XRF) computed tomography (CT) system utilizing a cadmium telluride (CdTe) detector is described. The CT system is of the first generation type and consists of a cerium x-ray generator, a turn table, a translation stage, a two-stage controller, a CdTe spectrometer, a multichannel analyzer (MCA), a counter board (CB), and a personal computer (PC). When an object is exposed by the x-ray generator, iodine K-series fluorescences are produced and are detected from vertical direction to x-ray axis using the spectrometer. Fluorescent photons are selected out using the MCA and are counted by the PC via CB, and XRF CT is performed by repeating translation and rotation of an object.

  6. MSL Chemistry and Mineralogy X-ray Diffraction X-ray Fluorescence (CheMin) Instrument

    NASA Astrophysics Data System (ADS)

    Zimmerman, W.; Blake, D.; Harris, W.; Morookian, J. M.; Randall, D.; Reder, L. J.; Sarrazin, P.

    This paper provides an overview of the Mars Science Laboratory (MSL) Chemistry and Mineralogy X-ray Diffraction (XRD), X-ray Fluorescence (XRF) (CheMin) Instrument, an element of the landed Curiosity rover payload, which landed on Mars in August of 2012. The scientific goal of the MSL mission is to explore and quantitatively assess regions in Gale Crater as a potential habitat for life - past or present. The CheMin instrument will receive Martian rock and soil samples from the MSL Sample Acquisition/Sample Processing and Handling (SA/SPaH) system, and process it utilizing X-Ray spectroscopy methods to determine mineral composition. The Chemin instrument will analyze Martian soil and rocks to enable scientists to investigate geophysical processes occurring on Mars. The CheMin science objectives and proposed surface operations are described along with the CheMin hardware with an emphasis on the system engineering challenges associated with developing such a complex instrument.

  7. Capillary optics for micro x-ray fluorescence analysis

    SciTech Connect

    Bjeoumikhov, A.; Langhoff, N.; Bjeoumikhova, S.; Wedell, R.

    2005-06-15

    Practically achieved parameters of capillary optics are presented. A micro x-ray fluorescence (XRF) arrangement was realized by using a microfocus x-ray tube and a capillary optic. Several examples for application of micro XRF are given. It was shown that polycapillary lenses free of the 'halo effect' well suited for micro XRF of heavy elements can be manufactured. Limits of opportunities for micro XRF applications and further development for micro XRF by using capillary optics are analyzed.

  8. X-ray Fluorescence (XRF) Assay Using Laser Compton Scattered (LCS) X-rays

    NASA Astrophysics Data System (ADS)

    Naeem, Syed F.; Chouffani, Khalid; Wells, Douglas P.

    2009-03-01

    Laser Compton Scattered (LCS) X-rays are produced as a result of the interaction between accelerated electrons and a laser beam. The yield of LCS X-rays is dependent on the laser power, angle of collision between interacting particles, and the electron linear accelerator's (linac) electron beam energy and its current. One of our research goals at the Idaho Accelerator Center (IAC) focuses on applications such as detection and imaging of fissionable isotopes for nuclear non-proliferation, safeguards and homeland security. Quasi monochromatic LCS X-rays offer much better signal-to-noise ratios for such applications. The energy of LCS X-rays is tunable, that enable element-specific analysis. Two sharp 36.5 keV and 98.4 keV LCS peaks were observed in two separate experiments based on electron beams tuned at 32 MeV and 37 MeV, that were brought in collision with the (Power)peak = 4 GW Nd.YAG laser operating at 532 nm and 266 nm wavelengths. The linac was operating at 60 Hz with an electron beam pulse length of about 50 ps and a peak current of about 7 A. We exploited X-ray fluorescence (XRF) techniques to identify elemental Kα1, Kα2, and Kβ1 lines in a high-purity germanium (HPGe) detector, with a 0.5 mm thick Beryllium (Be) absorbing layer, emitted from tin (Sn), cadmium (Cd), silver (Ag), gold (Au), and lead (Pb) foils with thicknesses ranging from 25-500 μm, following absorption of 36.1 keV and 98.4 keV LCS X-rays. These reference foils were used for the proof of principle, and some have atomic numbers near to that of relevant fission products.

  9. Remote X-Ray Diffraction and X-Ray Fluorescence Analysis on Planetary Surfaces

    NASA Technical Reports Server (NTRS)

    Blake, David F.; DeVincenzi, D. (Technical Monitor)

    1999-01-01

    The legacy of planetary X-ray Diffraction (XRD) and X-ray Fluorescence (XRF) began in 1960 when W. Parish proposed an XRD instrument for deployment on the moon. The instrument was built and flight qualified, but the Lunar XRD program was cancelled shortly before the first human landing in 1969. XRF chemical data have been collected in situ by surface landers on Mars (Viking 1 & 2, Pathfinder) and Venus (Venera 13 & 14). These highly successful experiments provide critical constraints on our current understanding of surface processes and planetary evolution. However, the mineralogy, which is more critical to planetary surface science than simple chemical analysis, will remain unknown or will at best be imprecisely constrained until X-ray diffraction (XRD) data are collected. Recent progress in X-ray detector technology allows the consideration of simultaneous XRD (mineralogic analysis) and high-precision XRF (elemental analysis) in systems miniaturized to the point where they can be mounted on fixed landers or small robotic rovers. There is a variety of potential targets for XRD/XRF equipped landers within the solar system, the most compelling of which are the poles of the moon, the southern highlands of Mars and Europa.

  10. Detection of terrestrial radionuclides with X-ray fluorescence analysis.

    PubMed

    Trojek, T; Čechák, T

    2015-06-01

    This paper provides an overview of analytical methods frequently used to identify terrestrial radionuclides in samples. While radioactivity is normally measured through the ionising radiation produced during the spontaneous decay of unstable atoms, selected radionuclides or their chemical elements can be quantified with instrumental techniques based on stimulated emission or counting of atoms. The advantages and disadvantages of these analytical methods are discussed. Particular attention is paid to X-ray fluorescence analysis of materials containing uranium and thorium. It is also possible to determine the area distributions of these chemical elements in samples with the use of scanning X-ray fluorescence systems.

  11. Detection of terrestrial radionuclides with X-ray fluorescence analysis.

    PubMed

    Trojek, T; Čechák, T

    2015-06-01

    This paper provides an overview of analytical methods frequently used to identify terrestrial radionuclides in samples. While radioactivity is normally measured through the ionising radiation produced during the spontaneous decay of unstable atoms, selected radionuclides or their chemical elements can be quantified with instrumental techniques based on stimulated emission or counting of atoms. The advantages and disadvantages of these analytical methods are discussed. Particular attention is paid to X-ray fluorescence analysis of materials containing uranium and thorium. It is also possible to determine the area distributions of these chemical elements in samples with the use of scanning X-ray fluorescence systems. PMID:25977354

  12. X-ray fluorescence analysis of various alloys. Part 1

    SciTech Connect

    Charles, J.W. Jr.; Ferguson, M.R.; Eager, M.H.

    1980-02-15

    For a number of years, x-ray fluorescence spectrometry has been used in the Y-12 Plant Laboratory for the analysis of a wide variety of materials. During the past few years, the technique has been applied to the analysis of a large number of experimental alloys. The general procedure consists of the following steps: (1) ignition of the alloy to oxides, (2) addition of suitable internal standards, (3) dissolution of the oxides and internal standards by sodium tetraborate (borax) fusion, (4) casting a pellet from the fusion in a graphite mold (Figure 1), and (5) determination of the major constituents by x-ray fluorescence spectrometry.

  13. X-ray Methods in High-Intensity Discharges and Metal-Halide Lamps: X-ray Induced Fluorescence

    SciTech Connect

    Curry, John J.; Lapatovich, Walter P.; Henins, Albert

    2011-12-09

    We describe the use of x-ray induced fluorescence to study metal-halide high-intensity discharge lamps and to measure equilibrium vapor pressures of metal-halide salts. The physical principles of metal-halide lamps, relevant aspects of x-ray-atom interactions, the experimental method using synchrotron radiation, and x-ray induced fluorescence measurements relevant to metal-halide lamps are covered.

  14. Assessment of asthmatic inflammation using hybrid fluorescence molecular tomography-x-ray computed tomography

    NASA Astrophysics Data System (ADS)

    Ma, Xiaopeng; Prakash, Jaya; Ruscitti, Francesca; Glasl, Sarah; Stellari, Fabio Franco; Villetti, Gino; Ntziachristos, Vasilis

    2016-01-01

    Nuclear imaging plays a critical role in asthma research but is limited in its readings of biology due to the short-lived signals of radio-isotopes. We employed hybrid fluorescence molecular tomography (FMT) and x-ray computed tomography (XCT) for the assessment of asthmatic inflammation based on resolving cathepsin activity and matrix metalloproteinase activity in dust mite, ragweed, and Aspergillus species-challenged mice. The reconstructed multimodal fluorescence distribution showed good correspondence with ex vivo cryosection images and histological images, confirming FMT-XCT as an interesting alternative for asthma research.

  15. Archaeometrical studies using X-ray fluorescence methods

    SciTech Connect

    Pauna, Catalina; Constantinescu, B.; Constantin, F.; Bugoi, R.; Stan, D.; Vasilescu, A.

    2010-04-26

    Elemental analysis contributes to authentication (knowing the elemental composition and considering the information about the usual composition of the objects in different historical periods it can be established if the item is original or fake), provenance studies (minor and trace elements indicates ores origin and 'consequently' mines location), (relative) dating of archaeological objects (e.g. for painted items--the chemical recipes for pigments can offer information about the age of objects). The paper gives a general layout for the NIPNE Archaeometry Laboratory's applications using X-Ray Fluorescence (XRF), micro--Proton Induced X-Ray Emission (micro-PIXE), micro-Synchrotron Radiation Induced X-Ray Fluorescence (micro--SR-XRF) methods.

  16. X-ray fluorescence analysis major elements in silicate minerals

    SciTech Connect

    Hagan, R.C.

    1982-09-01

    An automated wavelength-dispersive x-ray fluorescence spectrometer is operational for analysis of major elements in rocks and minerals. Procedures for trace-element analysis are being developed. Sample preparation methods and analytical techniques are similar to those commonly used elsewhere, but data reduction is conducted by the Fundamental Parameters program developed by Criss. Unlike empirically derived calibration curves, this data reduction method considers x-ray absorption and secondary fluorescence, which vary with differences in sample composition. X-ray intensities for each element from several standards are averaged to develop a theoretical standard for comparison with samples of unknown composition. Accurate data for samples with wide compositional ranges result from these data reduction and standardization techniques.

  17. MSL Chemistry and Mineralogy X-Ray Diffraction X-Ray Fluorescence (CheMin) Instrument

    NASA Technical Reports Server (NTRS)

    Zimmerman, Wayne; Blake, Dave; Harris, William; Morookian, John Michael; Randall, Dave; Reder, Leonard J.; Sarrazin, Phillipe

    2013-01-01

    This paper provides an overview of the Mars Science Laboratory (MSL) Chemistry and Mineralogy Xray Diffraction (XRD), X-ray Fluorescence (XRF) (CheMin) Instrument, an element of the landed Curiosity rover payload, which landed on Mars in August of 2012. The scientific goal of the MSL mission is to explore and quantitatively assess regions in Gale Crater as a potential habitat for life - past or present. The CheMin instrument will receive Martian rock and soil samples from the MSL Sample Acquisition/Sample Processing and Handling (SA/SPaH) system, and process it utilizing X-Ray spectroscopy methods to determine mineral composition. The Chemin instrument will analyze Martian soil and rocks to enable scientists to investigate geophysical processes occurring on Mars. The CheMin science objectives and proposed surface operations are described along with the CheMin hardware with an emphasis on the system engineering challenges associated with developing such a complex instrument.

  18. Instrument and method for X-ray diffraction, fluorescence, and crystal texture analysis without sample preparation

    NASA Technical Reports Server (NTRS)

    Gendreau, Keith (Inventor); Martins, Jose Vanderlei (Inventor); Arzoumanian, Zaven (Inventor)

    2010-01-01

    An X-ray diffraction and X-ray fluorescence instrument for analyzing samples having no sample preparation includes a X-ray source configured to output a collimated X-ray beam comprising a continuum spectrum of X-rays to a predetermined coordinate and a photon-counting X-ray imaging spectrometer disposed to receive X-rays output from an unprepared sample disposed at the predetermined coordinate upon exposure of the unprepared sample to the collimated X-ray beam. The X-ray source and the photon-counting X-ray imaging spectrometer are arranged in a reflection geometry relative to the predetermined coordinate.

  19. HIgh Rate X-ray Fluorescence Detector

    SciTech Connect

    Grudberg, Peter Matthew

    2013-04-30

    The purpose of this project was to develop a compact, modular multi-channel x-ray detector with integrated electronics. This detector, based upon emerging silicon drift detector (SDD) technology, will be capable of high data rate operation superior to the current state of the art offered by high purity germanium (HPGe) detectors, without the need for liquid nitrogen. In addition, by integrating the processing electronics inside the detector housing, the detector performance will be much less affected by the typically noisy electrical environment of a synchrotron hutch, and will also be much more compact than current systems, which can include a detector involving a large LN2 dewar and multiple racks of electronics. The combined detector/processor system is designed to match or exceed the performance and features of currently available detector systems, at a lower cost and with more ease of use due to the small size of the detector. In addition, the detector system is designed to be modular, so a small system might just have one detector module, while a larger system can have many you can start with one detector module, and add more as needs grow and budget allows. The modular nature also serves to simplify repair. In large part, we were successful in achieving our goals. We did develop a very high performance, large area multi-channel SDD detector, packaged with all associated electronics, which is easy to use and requires minimal external support (a simple power supply module and a closed-loop water cooling system). However, we did fall short of some of our stated goals. We had intended to base the detector on modular, large-area detectors from Ketek GmbH in Munich, Germany; however, these were not available in a suitable time frame for this project, so we worked instead with pnDetector GmbH (also located in Munich). They were able to provide a front-end detector module with six 100 m^2 SDD detectors (two monolithic arrays of three elements each) along with

  20. Measuring and interpreting X-ray fluorescence from planetary surfaces.

    PubMed

    Owens, Alan; Beckhoff, Burkhard; Fraser, George; Kolbe, Michael; Krumrey, Michael; Mantero, Alfonso; Mantler, Michael; Peacock, Anthony; Pia, Maria-Grazia; Pullan, Derek; Schneider, Uwe G; Ulm, Gerhard

    2008-11-15

    As part of a comprehensive study of X-ray emission from planetary surfaces and in particular the planet Mercury, we have measured fluorescent radiation from a number of planetary analog rock samples using monochromatized synchrotron radiation provided by the BESSY II electron storage ring. The experiments were carried out using a purpose built X-ray fluorescence (XRF) spectrometer chamber developed by the Physikalisch-Technische Bundesanstalt, Germany's national metrology institute. The XRF instrumentation is absolutely calibrated and allows for reference-free quantitation of rock sample composition, taking into account secondary photon- and electron-induced enhancement effects. The fluorescence data, in turn, have been used to validate a planetary fluorescence simulation tool based on the GEANT4 transport code. This simulation can be used as a mission analysis tool to predict the time-dependent orbital XRF spectral distributions from planetary surfaces throughout the mapping phase. PMID:18855420

  1. X-ray fluorescence microscopy of olfactory receptor neurons

    NASA Astrophysics Data System (ADS)

    Dučić, T.; Breunig, E.; Schild, D.; Herbst, J.; Nováková, E.; Susini, J.; Tucoulu, R.; Salditt, T.

    2009-09-01

    We report a x-ray fluorescence microscopy study of cells and tissues from the olfactory system of Xenopus laevis. In this experiment we focus on sample preparation and experimental issues, and present first results of fluorescence maps of the elemental distribution of Cl, K, Ca, P, S and Na both in individual isolated neural cells and in cross-sections of the same tissue.

  2. Silver coins analyses by X-ray fluorescence methods.

    PubMed

    Torrisi, L; Italiano, A; Cutroneo, M; Gentile, C; Torrisi, A

    2013-01-01

    The investigation on the differences occurring in the manufacture of silver coins allows to get information on their elemental composition and represents a powerful support to the methodology to identify the producing technologies, workshops being also instrumental to distinguish between original and counterfeit ones. Aim of the present work is to study recent and old silver coins through non-destructive X-Ray Fluorescence (XRF) analysis. The XRF was applied to extend the analysis to the deepest layers of the coins; for surface layers an X-ray tube or an electron beam were employed to induce the atom fluorescence to obtain information on the surface elemental composition. Moreover, a detailed study has been performed to evaluate the influence of the surface curvature on the measurement, by deducing a proper corrective factor to keep into account in the data analysis. The elemental atomic composition was measured for each coin, mainly by means of the X-ray tube excitation for the bulk and the electron Scanning Electron Microscope (SEM) microbeam probe for the surface patina analysis. Ionization was induced by an X-ray tube using an Ag anode for the bulk and by an electron microprobe for the surface composition. X-ray detection was performed by using a semiconductor Si device cooled by a Peltier system. The Ag L-lines X-ray yield is affected by coin surface morphology and geometry. The comparison between coin spectra and standard samples, shows that the Ag quantitative analysis is influenced by error of the atomic concentration lower that 10%. PMID:24004868

  3. Portable energy dispersive X-ray fluorescence and X-ray diffraction and radiography system for archaeometry

    NASA Astrophysics Data System (ADS)

    Mendoza Cuevas, Ariadna; Perez Gravie, Homero

    2011-03-01

    Starting on a laboratory developed portable X-ray fluorescence (PXRF) spectrometer; three different analytical results can be performed: analysis of chemical elements, analysis of major chemical crystalline phase and structural analysis, which represents a contribution to a new, low cost development of portable X-ray analyzer; since these results are respectively obtained with independent equipments for X-ray fluorescence, X-ray diffraction and radiography. Detection limits of PXRF were characterized using standard reference materials for ceramics, glass, bronze and bones, which are the main materials requiring quantitative analysis in art and archeological objects. A setup for simultaneous energy dispersive X-ray fluorescence and diffraction (ED (XRF-XRD)) in the reflection mode has been tested for in situ and non-destructive analysis according to the requirements of art objects inspection. The system uses a single low power X-ray tube and an X-ray energy dispersive detector to measure X-ray diffraction spectrum at a fixed angle. Application to the identification of jadeite-jade mineral in archeological objects by XRD is presented. A local high resolution radiography image obtained with the same low power X-ray tube allows for studies in painting and archeological bones.

  4. Modeling of X-Ray Fluorescence for Quantitative Analysis

    NASA Astrophysics Data System (ADS)

    Zarkadas, Charalambos

    2010-03-01

    Quantitative XRF algorithms involve mathematical procedures intended to solve a set of equations expressing the total fluorescence intensity of selected X-ray element lines emitted after sample irradiation by a photon source. These equations [1] have been derived under the assumptions of a parallel exciting beam and that of a perfectly flat and uniform sample and have been extended up to date to describe composite cases such as multilayered samples and samples exhibiting particle size effects. In state of the art algorithms the equations include most of the physical processes which can contribute to the measured fluorescence signal and make use of evaluated databases for the Fundamental Parameters included in the calculations. The accuracy of the results obtained depends on a great extent on the completeness of the model used to describe X-ray fluorescence intensities and on the compliance of the actual experimental conditions to the basic assumptions under which the mathematical formulas were derived.

  5. X-ray fluorescence measurements of dissolved gas and cavitation

    NASA Astrophysics Data System (ADS)

    Duke, Daniel J.; Kastengren, Alan L.; Swantek, Andrew B.; Matusik, Katarzyna E.; Powell, Christopher F.

    2016-10-01

    The dynamics of dissolved gas and cavitation are strongly coupled, yet these phenomena are difficult to measure in-situ. Both create voids in the fluid that can be difficult to distinguish. We present an application of X-ray fluorescence in which liquid density and total noncondensible gas concentration (both dissolved and nucleated) are simultaneously measured. The liquid phase is doped with 400 ppm of a bromine tracer, and dissolved air is removed and substituted with krypton. Fluorescent emission at X-ray wavelengths is simultaneously excited from the Br and Kr with a focused monochromatic X-ray beam from a synchrotron source. We measure the flow in a cavitating nozzle 0.5 mm in diameter. From Br fluorescence, total displacement of the liquid is measured. From Kr fluorescence, the mass fraction of both dissolved and nucleated gas is measured. Volumetric displacement of liquid due to both cavitation and gas precipitation can be separated through estimation of the local equilibrium dissolved mass fraction. The uncertainty in the line of sight projected densities of the liquid and gas phases is 4-6 %. The high fluorescence yields and energies of Br and Kr allow small mass fractions of gas to be measured, down to 10-5, with an uncertainty of 8 %. These quantitative measurements complement existing optical diagnostic techniques and provide new insight into the diffusion of gas into cavitation bubbles, which can increase their internal density, pressure and lifetimes by orders of magnitude.

  6. High-spatial-resolution nanoparticle x-ray fluorescence tomography

    NASA Astrophysics Data System (ADS)

    Larsson, Jakob C.; Vâgberg, William; Vogt, Carmen; Lundström, Ulf; Larsson, Daniel H.; Hertz, Hans M.

    2016-03-01

    X-ray fluorescence tomography (XFCT) has potential for high-resolution 3D molecular x-ray bio-imaging. In this technique the fluorescence signal from targeted nanoparticles (NPs) is measured, providing information about the spatial distribution and concentration of the NPs inside the object. However, present laboratory XFCT systems typically have limited spatial resolution (>1 mm) and suffer from long scan times and high radiation dose even at high NP concentrations, mainly due to low efficiency and poor signal-to-noise ratio. We have developed a laboratory XFCT system with high spatial resolution (sub-100 μm), low NP concentration and vastly decreased scan times and dose, opening up the possibilities for in-vivo small-animal imaging research. The system consists of a high-brightness liquid-metal-jet microfocus x-ray source, x-ray focusing optics and an energy-resolving photon-counting detector. By using the source's characteristic 24 keV line-emission together with carefully matched molybdenum nanoparticles the Compton background is greatly reduced, increasing the SNR. Each measurement provides information about the spatial distribution and concentration of the Mo nanoparticles. A filtered back-projection method is used to produce the final XFCT image.

  7. Development and applications of grazing exit micro X-ray fluorescence instrument using a polycapillary X-ray lens*1

    NASA Astrophysics Data System (ADS)

    Emoto, T.; Sato, Y.; Konishi, Y.; Ding, X.; Tsuji, K.

    2004-08-01

    A polycapillary X-ray lens is an effective optics to obtain a μm-size X-ray beam for micro-X-ray fluorescence spectrometry (μ-XRF). We developed a μ-XRF instrument using a polycapillary X-ray lens, which also enabled us to perform Grazing Exit μ-XRF (GE-μ-XRF). The evaluated diameter of the primary X-ray beam was 48 μm at the focal distance of the X-ray lens. Use of this instrument enabled two-dimensional mapping of the elemental distributions during growth of the plant "Quinoa". The results of the mapping revealed elemental transition during growth. In addition, a small region of thin film was analyzed by GE-μ-XRF. We expect that GE-μ-XRF will become an effective method of estimating the film thickness of a small region.

  8. Proton-induced x-ray fluorescence CT imaging

    SciTech Connect

    Bazalova-Carter, Magdalena Xing, Lei; Ahmad, Moiz; Matsuura, Taeko; Takao, Seishin; Shirato, Hiroki; Umegaki, Kikuo; Matsuo, Yuto; Fahrig, Rebecca

    2015-02-15

    Purpose: To demonstrate the feasibility of proton-induced x-ray fluorescence CT (pXFCT) imaging of gold in a small animal sized object by means of experiments and Monte Carlo (MC) simulations. Methods: First, proton-induced gold x-ray fluorescence (pXRF) was measured as a function of gold concentration. Vials of 2.2 cm in diameter filled with 0%–5% Au solutions were irradiated with a 220 MeV proton beam and x-ray fluorescence induced by the interaction of protons, and Au was detected with a 3 × 3 mm{sup 2} CdTe detector placed at 90° with respect to the incident proton beam at a distance of 45 cm from the vials. Second, a 7-cm diameter water phantom containing three 2.2-diameter vials with 3%–5% Au solutions was imaged with a 7-mm FWHM 220 MeV proton beam in a first generation CT scanning geometry. X-rays scattered perpendicular to the incident proton beam were acquired with the CdTe detector placed at 45 cm from the phantom positioned on a translation/rotation stage. Twenty one translational steps spaced by 3 mm at each of 36 projection angles spaced by 10° were acquired, and pXFCT images of the phantom were reconstructed with filtered back projection. A simplified geometry of the experimental data acquisition setup was modeled with the MC TOPAS code, and simulation results were compared to the experimental data. Results: A linear relationship between gold pXRF and gold concentration was observed in both experimental and MC simulation data (R{sup 2} > 0.99). All Au vials were apparent in the experimental and simulated pXFCT images. Specifically, the 3% Au vial was detectable in the experimental [contrast-to-noise ratio (CNR) = 5.8] and simulated (CNR = 11.5) pXFCT image. Due to fluorescence x-ray attenuation in the higher concentration vials, the 4% and 5% Au contrast were underestimated by 10% and 15%, respectively, in both the experimental and simulated pXFCT images. Conclusions: Proton-induced x-ray fluorescence CT imaging of 3%–5% gold solutions in a

  9. Proton-induced x-ray fluorescence CT imaging

    PubMed Central

    Bazalova-Carter, Magdalena; Ahmad, Moiz; Matsuura, Taeko; Takao, Seishin; Matsuo, Yuto; Fahrig, Rebecca; Shirato, Hiroki; Umegaki, Kikuo; Xing, Lei

    2015-01-01

    Purpose: To demonstrate the feasibility of proton-induced x-ray fluorescence CT (pXFCT) imaging of gold in a small animal sized object by means of experiments and Monte Carlo (MC) simulations. Methods: First, proton-induced gold x-ray fluorescence (pXRF) was measured as a function of gold concentration. Vials of 2.2 cm in diameter filled with 0%–5% Au solutions were irradiated with a 220 MeV proton beam and x-ray fluorescence induced by the interaction of protons, and Au was detected with a 3 × 3 mm2 CdTe detector placed at 90° with respect to the incident proton beam at a distance of 45 cm from the vials. Second, a 7-cm diameter water phantom containing three 2.2-diameter vials with 3%–5% Au solutions was imaged with a 7-mm FWHM 220 MeV proton beam in a first generation CT scanning geometry. X-rays scattered perpendicular to the incident proton beam were acquired with the CdTe detector placed at 45 cm from the phantom positioned on a translation/rotation stage. Twenty one translational steps spaced by 3 mm at each of 36 projection angles spaced by 10° were acquired, and pXFCT images of the phantom were reconstructed with filtered back projection. A simplified geometry of the experimental data acquisition setup was modeled with the MC TOPAS code, and simulation results were compared to the experimental data. Results: A linear relationship between gold pXRF and gold concentration was observed in both experimental and MC simulation data (R2 > 0.99). All Au vials were apparent in the experimental and simulated pXFCT images. Specifically, the 3% Au vial was detectable in the experimental [contrast-to-noise ratio (CNR) = 5.8] and simulated (CNR = 11.5) pXFCT image. Due to fluorescence x-ray attenuation in the higher concentration vials, the 4% and 5% Au contrast were underestimated by 10% and 15%, respectively, in both the experimental and simulated pXFCT images. Conclusions: Proton-induced x-ray fluorescence CT imaging of 3%–5% gold solutions in a small animal

  10. Elemental analysis using a handheld X-Ray fluorescence spectrometer

    USGS Publications Warehouse

    Groover, Krishangi; Izbicki, John

    2016-06-24

    The U.S. Geological Survey is collecting geologic samples from local stream channels, aquifer materials, and rock outcrops for studies of trace elements in the Mojave Desert, southern California. These samples are collected because geologic materials can release a variety of elements to the environment when exposed to water. The samples are to be analyzed with a handheld X-ray fluorescence (XRF) spectrometer to determine the concentrations of up to 27 elements, including chromium.

  11. Elemental analysis using a handheld X-Ray fluorescence spectrometer

    USGS Publications Warehouse

    Groover, Krishangi; Izbicki, John

    2016-01-01

    The U.S. Geological Survey is collecting geologic samples from local stream channels, aquifer materials, and rock outcrops for studies of trace elements in the Mojave Desert, southern California. These samples are collected because geologic materials can release a variety of elements to the environment when exposed to water. The samples are to be analyzed with a handheld X-ray fluorescence (XRF) spectrometer to determine the concentrations of up to 27 elements, including chromium.

  12. High spatial resolution in x-ray fluorescence

    SciTech Connect

    Zahrt, J.D.

    1986-01-01

    The design of diffracting crystals for use in x-ray fluorescence spectrometers is discussed. Characteristics of the Johan and Johansson geometries are discussed and intensity profiles are developed. If the diffraction line has a finite width, concentration gradients will not be faithfully reproduced by gradients in the signal as the sample is scanned. Boundary effects for four types of concentration gradient are presented; as step function, linear gradients, exponential gradient, and Gaussian gradient. (DWL) 13 refs., 8 figs.

  13. Identifications studies of Lauha Bhasma by X-ray diffraction and X-ray fluorescence

    PubMed Central

    Bhargava, S. C.; Reddy, K. R. C; Sastry, G. V. S

    2012-01-01

    Procedures for preparation of Lauha Bhasma are described in ancient texts of Ayurveda. These procedures also begin with different source material for iron such as Teekshna Lauha and Kanta Lauha etc. In the present study, we have selected different source materials viz. magnetite iron ore for Kanta Lauha and pure (Armco grade) iron turnings for Teekshna Lauha. The standard procedures of preparation of Lauha Bhasma are carried out in identical conditions for these two raw materials. The final product from the Puta are characterized by using X-ray diffraction and X-ray fluorescence spectroscopy to understanding the crystallographic form or forms of iron oxides and their composition at the end of each Puta. The iron content at the end of repeated Putas (18 for Kanta Lauha and 20 for Teekshna Lauha) have shown a decrease in case of Teekshna Lauha since the starting material is pure iron while it showed only marginal decreases in the case of Kanta Lauha because the Fe3O4 of magnetite is undergoing oxidation to Fe2O3. The trace elements remain within the Bhasma in the form of various oxides of Si, Al, Ca, etc. PMID:23049200

  14. Identifications studies of Lauha Bhasma by X-ray diffraction and X-ray fluorescence.

    PubMed

    Bhargava, S C; Reddy, K R C; Sastry, G V S

    2012-01-01

    Procedures for preparation of Lauha Bhasma are described in ancient texts of Ayurveda. These procedures also begin with different source material for iron such as Teekshna Lauha and Kanta Lauha etc. In the present study, we have selected different source materials viz. magnetite iron ore for Kanta Lauha and pure (Armco grade) iron turnings for Teekshna Lauha. The standard procedures of preparation of Lauha Bhasma are carried out in identical conditions for these two raw materials. The final product from the Puta are characterized by using X-ray diffraction and X-ray fluorescence spectroscopy to understanding the crystallographic form or forms of iron oxides and their composition at the end of each Puta. The iron content at the end of repeated Putas (18 for Kanta Lauha and 20 for Teekshna Lauha) have shown a decrease in case of Teekshna Lauha since the starting material is pure iron while it showed only marginal decreases in the case of Kanta Lauha because the Fe(3)O(4) of magnetite is undergoing oxidation to Fe(2)O(3). The trace elements remain within the Bhasma in the form of various oxides of Si, Al, Ca, etc. PMID:23049200

  15. Micro-X-ray Fluorescence in Food Forensics

    NASA Astrophysics Data System (ADS)

    St. Jeor, V. L.; Muroski, A. R.; McGuire, C.; Lape, A.

    2011-09-01

    All forms of commercially available x-ray microscopy are finding growing application opportunities within the food industry; this includes micro-x-ray fluorescence (micro-XRF) and micro-CT. In this example, we demonstrate the use of micro-XRF in discovering the cause for a particularly troubling anomaly discovered by one of our customers during the production of a batch of their chicken hotdogs. Although their claim was that iron filings must be present to cause such anomalies, no "iron filings" were discovered in our initial observations. More traditional EDS methods were attempted to determine the elemental content within these anomalies, but they were not sensitive enough to detect the small amounts of iron that were, in fact, present. Nor could EDS determine the source for this minute amount of iron. Only micro-XRF displayed the required sensitivity to detect the iron and to make an initial diagnosis regarding its potential source. Visible spectroscopy confirms. Instrumentation is reviewed.

  16. Elemental mapping with an X-ray fluorescence imaging microscope

    NASA Astrophysics Data System (ADS)

    Yamamoto, Kimitake; Watanabe, Norio; Takeuchi, Akihisa; Takano, Hidekazu; Aota, Tatuya; Kumegawa, Masaru; Ohigashi, Takuji; Tanoue, Ryuichi; Yokosuka, Hiroki; Aoki, Sadao

    2000-05-01

    An X-ray fluorescence (XRF) imaging microscope with a Wolter-type grazing-incidence mirror as an objective was constructed at the beamline 39XU of SPring-8 (8 GeV, 70 mA) at Japan Synchrotron Radiation Institute. The monochromatic undulator X-rays in the energy range of 6-10 keV were used to produce XRF of a specimen. The microscope system was set normal to the incident beam to reduce elastic scattering from a specimen and to improve signal/background ratio. The two-dimensional elemental mappings of a test specimen (Cu, Ni, Fe wires) and inclusions (Fe, Co, Ni) in a synthesized diamond could be obtained by utilizing the absorption edges of the corresponding elements.

  17. X-ray fluorescence spectrometry of asteroid Itokawa by Hayabusa.

    PubMed

    Okada, Tatsuaki; Shirai, Kei; Yamamoto, Yukio; Arai, Takehiko; Ogawa, Kazunori; Hosono, Kozue; Kato, Manabu

    2006-06-01

    X-ray fluorescence spectrometry of asteroid 25143 Itokawa was performed by the x-ray spectrometer onboard Hayabusa during the first touchdown on 19 November 2005. We selected those data observed during relatively enhanced solar activity and determined average elemental mass ratios of Mg/Si = 0.78 +/- 0.09 and Al/Si = 0.07 +/- 0.03. Our preliminary results suggest that Itokawa has a composition consistent with that of ordinary chondrites, but primitive achondrites cannot be ruled out. Among ordinary chondrites, LL- or L-chondrites appear to be more likely than H-chondrites. No substantial regional difference was found on the asteroid surface, indicating its homogeneity in composition.

  18. Advances in X-ray Reflectivity (XRR) and X-ray Fluorescence (XRF) Measurements Provide Unique Advantages for Semiconductor Applications

    NASA Astrophysics Data System (ADS)

    Spear, Jennifer; Murakami, Hiroyuki; Terada, Shinichi

    2003-09-01

    We have developed a thin-film metrology tool that fulfills the metrology requirements for the production of 65nm node technology and beyond. This tool combines X-ray Reflectivity (XRR) and X-ray Fluorescence (XRF) measurements to provide accurate, high throughput, measurements. Improvements in both the XRR and XRF configurations were made to allow high throughput measurements on films as thin as 0.5 nm. The source intensity for the XRR measurements was increased using focusing X-ray optics. Wafer alignment, which is critical for XRR measurements to be accurate, is done using both X-rays and lasers to reduce the time required. A monochromatic X-ray source is used for XRF measurements since peak-to-background ratio is extremely important when detecting the XRF signal from ultra-thin films.

  19. The Apollo 15 X-ray fluorescence experiment

    NASA Technical Reports Server (NTRS)

    Adler, I.; Trombka, J.; Gerard, J.; Schmadebeck, R.; Lowman, P.; Blodgett, H.; Yin, L.; Eller, E.; Lamothe, R.; Gorenstein, P.

    1972-01-01

    The CSM spectrometric data on the lunar surface with respect to its chemical composition are presented for Al, Mg, and Si as Al/Si and Mg/Si ratios for the various features overflow by the spacecraft. The lunar surface measurements involved observations of the intensity and characteristic energy distribution of the secondary or fluorescent X-rays produced by the interaction of solar X-rays with the lunar surface. The results showed that the highlands and maria are chemically different, with the highlands having considerably more Al and less Mg than the maria. The mare-highland contact is quite sharp and puts a limit on the amount of horizontal transport of material. The X-ray data suggest that the dominant rock type of the lunar highlands is a plagioclase-rich pyroxene bearing rock, probably anorthositic gabbro or feldspathic basalt. Thus the moon appears to have a widespread differentiated crust (the highlands) systematically richer in Al and lower in Mg than the maria. This crust is pre-mare and may represent the first major internal differentiation of the moon.

  20. Simultaneous X-ray fluorescence and scanning X-ray diffraction microscopy at the Australian Synchrotron XFM beamline.

    PubMed

    Jones, Michael W M; Phillips, Nicholas W; van Riessen, Grant A; Abbey, Brian; Vine, David J; Nashed, Youssef S G; Mudie, Stephen T; Afshar, Nader; Kirkham, Robin; Chen, Bo; Balaur, Eugeniu; de Jonge, Martin D

    2016-09-01

    Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X-ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X-ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super-resolved ultra-structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step- and fly-scanning modes, robust, simultaneous XFM-SXDM is demonstrated. PMID:27577770

  1. MESSENGER X-Ray Spectrometer Detection of Electron-induced X-ray Fluorescence from Mercury's Surface

    NASA Astrophysics Data System (ADS)

    Starr, R. D.; Nittler, L. R.; Weider, S. Z.; Rhodes, E. A.; Schriver, D.; Schlemm, C. E., II; Solomon, S. C.

    2011-12-01

    The X-Ray Spectrometer (XRS) onboard the MESSENGER spacecraft measures elemental abundances on the surface of Mercury by detecting fluorescent X-ray emissions induced on the planet's surface by the incident solar X-ray flux. The most prominent fluorescent lines are the Kα lines from the elements Mg, Al, Si, S, Ca, Ti, and Fe (1-10 keV). The XRS began orbital observations on 23 March 2011 and has observed X-ray fluorescence from the surface of the planet during both "quiet" Sun and flaring conditions whenever a sunlit portion of Mercury has been within the XRS field of view. XRS can detect the characteristic X-rays of Mg, Al, and Si during quiet-Sun conditions, but solar flares are required to produce measureable signals from the elements of higher atomic number such as S, Ca, Ti, and Fe. Nevertheless, X-ray fluorescence up to the Ca fluorescent line (3.69 keV) has been detected from Mercury's surface at times when the XRS field of view included only unlit portions of the planet or during quiet-Sun illumination. To date, seven such events have been detected and are identified as electron-induced X-ray emission produced by ~1-10 keV electrons interacting with Mercury's surface. Electrons in this energy range were detected by the XRS during the three Mercury flybys, and since the beginning of orbital operations electrons of this same energy range have been detected by XRS during almost every orbit. These electron events last from minutes to tens of minutes. Electron transport models suggest that a large percentage of these quasi-trapped electrons do not complete even a single orbit about Mercury before impacting the surface. Knowledge of the precipitating electron distribution at the planet's surface makes it possible to infer surface composition from the measured fluorescent spectra, providing additional measurement opportunities for the XRS.

  2. Portable X-ray Fluorescence Unit for Analyzing Crime Scenes

    NASA Astrophysics Data System (ADS)

    Visco, A.

    2003-12-01

    Goddard Space Flight Center and the National Institute of Justice have teamed up to apply NASA technology to the field of forensic science. NASA hardware that is under development for future planetary robotic missions, such as Mars exploration, is being engineered into a rugged, portable, non-destructive X-ray fluorescence system for identifying gunshot residue, blood, and semen at crime scenes. This project establishes the shielding requirements that will ensure that the exposure of a user to ionizing radiation is below the U.S. Nuclear Regulatory Commission's allowable limits, and also develops the benchtop model for testing the system in a controlled environment.

  3. Apollo 15 Geochemical X-ray Fluorescence Experiment: Preliminary Report.

    PubMed

    Adler, I; Trombka, J; Gerard, J; Lowman, P; Schmadebeck, R; Blodget, H; Eller, E; Yin, L; Lamothe, R; Gorenstein, P; Bjorkholm, P

    1972-01-28

    Although only part of the information from the x-ray fluorescence geochemical experiment has been analyzed, it is clear that the experiment was highly successful. Significant compositional differences among and possibly within the maria and highlands have been detected. When viewed in the light of analyzed lunar rocks and soil samples, and the data from other lunar orbital experiments (in particular, the Apollo 15 gamma-ray spectroscopy experiment), the results indicate the existence of a differential lunar highland crust, probably feldspathic. This crust appears to be related to the plagioclase-rich materials previously found in the samples from Apollo 11, Apollo 12, Apollo 14, Apollo 15, and Luna 16.

  4. Determination of X-ray excitation spectra in micro X-ray fluorescence spectrometry with capillary optics

    NASA Astrophysics Data System (ADS)

    Perez, R. D.; Sosa, C.; Sbarato, V.; Leani, J.; Sánchez, H. J.

    2016-03-01

    The quantitative X-ray fluorescence microanalysis by fundamental parameters requires the knowledge of the energy distribution of the excitation beam. When this beam is produced by capillary optics, its high intensity and anisotropy complicate a direct determination. An alternative is an indirect determination based on measurement of induced X-ray fluorescence in a set of targets. In this work the X-ray excitation spectrum is determined by an iterative deconvolution process of the fundamental parameter expression for the X-ray fluorescence intensities. The method has the advantage that it does not require any assumption about the energy distribution of the X-ray source or the energy dependence of the lens transmission. Numerous XRF targets of pure elements with emission lines covering the full energy range of the X-ray source are employed. The only requirement on the targets is a high homogeneity in its composition. In fact, it does not impose any condition on the sample thickness. The accuracy observed in the validation process implemented with reference materials is similar to that reported with alternative approaches: 5% for main components, 10% for minor elements and 15% for trace elements.

  5. X-ray fluorescence microtomography analyzing reference samples

    NASA Astrophysics Data System (ADS)

    Pereira, G. R.; Lopes, R. T.; Anjos, M. J.; Rocha, H. S.; Pérez, C. A.

    2007-08-01

    The X-ray fluorescence microtomography (XRFCT) is a non-destructive technique to complement other techniques used for samples characterization. The common techniques provide only information on the attenuation coefficients (transmission microtomography) or electronic density (Compton microtomography) and no information on the distribution of the elements inside of the sample can be obtained in these cases. XRFCT is based on the detection of fluorescence photons emitted by the elements in the sample. As the energy of photons of fluorescence has a particular value for each element, it is possible to obtain the distribution of all the elements in a sample, since that a minimum of fluorescence signal is detected. The experiments were performed at the X-ray fluorescence beamline (D09B-XRF) of the Brazilian Synchrotron Light Source (LNLS), Campinas, Brazil. A monochromatic beam and a white beam was used for the excitation of the elements and the fluorescence photons have been detected by a HPGe detector, placed at 90° to the incident beam. The beam was monitored by an ionization chamber and a fast scintillator detector was used to detect the transmitted radiation. In order to study the performance of the system, some reference samples made of polyethylene filled with standard solutions were analyzed, and some tissues of human breast (normal tissue, benign tumor and malignant tumor) have been analyzed in order to verify the efficiency of the system in determination of the elemental distribution in these kinds of samples. All the tomographic images were reconstructed using a filtered-back projection algorithm. In the breast tissue samples, the elements of higher concentration were Zn, Cu and Fe.

  6. Determination of beryllium by using X-ray fluorescence spectrometry.

    PubMed

    Zawisza, Beata

    2008-03-01

    X-ray fluorescence spectrometry method is subject to certain difficulties and inconveniences for the elements having the atomic number 9 or less. These difficulties become progressively more severe as the atomic number decreases, and are quite serious for beryllium, which is practically indeterminable directly by XRF. Therefore, an indirect determination of beryllium that is based on the evaluation of cobalt in the precipitate is taken into consideration. In the thesis below, there is a description of a new, simple, and precise method by selective precipitation using hexamminecobalt(III) chloride and ammonium carbonate-EDTA solution as a complexing agent for the determining of a trace amount of beryllium using X-ray fluorescence spectrometry. The optimum conditions for [Co(NH(3))(6)][Be(2)(OH)(3)(CO(3))(2)(H(2)O)(2)].(3)H(2)O complex formation were studied. The complex was collected on the membrane filter, and the Co Kalpha line was measured by XRF. The method presents the advantages of the sample preparation and the elimination of the matrix effects due to the thin film obtained. The detection limit of the proposed method is 0.2 mg of beryllium. The method was successfully applied to beryllium determination in copper/ beryllium/cobalt alloys.

  7. X-Ray Fluorescence Imaging of Ancient Artifacts

    NASA Astrophysics Data System (ADS)

    Thorne, Robert; Geil, Ethan; Hudson, Kathryn; Crowther, Charles

    2011-03-01

    Many archaeological artifacts feature inscribed and/or painted text or figures which, through erosion and aging, have become difficult or impossible to read with conventional methods. Often, however, the pigments in paints contain metallic elements, and traces may remain even after visible markings are gone. A promising non-destructive technique for revealing these remnants is X-ray fluorescence (XRF) imaging, in which a tightly focused beam of monochromatic synchrotron radiation is raster scanned across a sample. At each pixel, an energy-dispersive detector records a fluorescence spectrum, which is then analyzed to determine element concentrations. In this way, a map of various elements is made across a region of interest. We have succesfully XRF imaged ancient Greek, Roman, and Mayan artifacts, and in many cases, the element maps have revealed significant new information, including previously invisible painted lines and traces of iron from tools used to carve stone tablets. X-ray imaging can be used to determine an object's provenance, including the region where it was produced and whether it is authentic or a copy.

  8. Preparation of tissue samples for X-ray fluorescence microscopy

    NASA Astrophysics Data System (ADS)

    Chwiej, Joanna; Szczerbowska-Boruchowska, Magdalena; Lankosz, Marek; Wojcik, Slawomir; Falkenberg, Gerald; Stegowski, Zdzislaw; Setkowicz, Zuzanna

    2005-12-01

    As is well-known, trace elements, especially metals, play an important role in the pathogenesis of many disorders. The topographic and quantitative elemental analysis of pathologically changed tissues may shed some new light on processes leading to the degeneration of cells in the case of selected diseases. An ideal and powerful tool for such purpose is the Synchrotron Microbeam X-ray Fluorescence technique. It enables the carrying out of investigations of the elemental composition of tissues even at the single cell level. The tissue samples for histopathological investigations are routinely fixed and embedded in paraffin. The authors try to verify the usefulness of such prepared tissue sections for elemental analysis with the use of X-ray fluorescence microscopy. Studies were performed on rat brain samples. Changes in elemental composition caused by fixation in formalin or paraformaldehyde and embedding in paraffin were examined. Measurements were carried out at the bending magnet beamline L of the Hamburger Synchrotronstrahlungslabor HASYLAB in Hamburg. The decrease in mass per unit area of K, Br and the increase in P, S, Fe, Cu and Zn in the tissue were observed as a result of the fixation. For the samples embedded in paraffin, a lower level of most elements was observed. Additionally, for these samples, changes in the composition of some elements were not uniform for different analyzed areas of rat brain.

  9. The X-ray Fluorescence Microscopy Beamline at the Australian Synchrotron

    SciTech Connect

    Paterson, D.; Jonge, M. D. de; Howard, D. L.; Lewis, W.; McKinlay, J.; Starritt, A.; Kusel, M.; Ryan, C. G.; Kirkham, R.; Moorhead, G.; Siddons, D. P.

    2011-09-09

    A hard x-ray micro-nanoprobe has commenced operation at the Australian Synchrotron providing versatile x-ray fluorescence microscopy across an incident energy range from 4 to 25 keV. Two x-ray probes are used to collect {mu}-XRF and {mu}-XANES for elemental and chemical microanalysis: a Kirkpatrick-Baez mirror microprobe for micron resolution studies and a Fresnel zone plate nanoprobe capable of 60-nm resolution. Some unique aspects of the beamline design and operation are discussed. An advanced energy dispersive x-ray fluorescence detection scheme named Maia has been developed for the beamline, which enables ultrafast x-ray fluorescence microscopy.

  10. Human thyroid specimen imaging by fluorescent x-ray computed tomography with synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Takeda, Tohoru; Yu, Quanwen; Yashiro, Toru; Yuasa, Tetsuya; Hasegawa, Yasuo; Itai, Yuji; Akatsuka, Takao

    1999-09-01

    Fluorescent x-ray computed tomography (FXCT) is being developed to detect non-radioactive contrast materials in living specimens. The FXCT system consists of a silicon (111) channel cut monochromator, an x-ray slit and a collimator for fluorescent x ray detection, a scanning table for the target organ and an x-ray detector for fluorescent x-ray and transmission x-ray. To reduce Compton scattering overlapped on the fluorescent K(alpha) line, incident monochromatic x-ray was set at 37 keV. The FXCT clearly imaged a human thyroid gland and iodine content was estimated quantitatively. In a case of hyperthyroidism, the two-dimensional distribution of iodine content was not uniform, and thyroid cancer had a small amount of iodine. FXCT can be used to detect iodine within thyroid gland quantitatively and to delineate its distribution.

  11. Determination of thorium by fluorescent x-ray spectrometry

    USGS Publications Warehouse

    Adler, I.; Axelrod, J.M.

    1955-01-01

    A fluorescent x-ray spectrographic method for the determination of thoria in rock samples uses thallium as an internal standard. Measurements are made with a two-channel spectrometer equipped with quartz (d = 1.817 A.) analyzing crystals. Particle-size effects are minimized by grinding the sample components with a mixture of silicon carbide and aluminum and then briquetting. Analyses of 17 samples showed that for the 16 samples containing over 0.7% thoria the average error, based on chemical results, is 4.7% and the maximum error, 9.5%. Because of limitations of instrumentation, 0.2% thoria is considered the lower limit of detection. An analysis can be made in about an hour.

  12. Resonant soft x-ray fluorescence studies of novel materials

    SciTech Connect

    Carlisle, J.A.; Terminello, L.J.; Hudson, E.A.; Shirley, E.L.; Jia, J.J.; Callcott, T.A.; Himpsel, F.J.; Ederer, D.L.; Perera, R.C.C.

    1995-02-08

    The authors are using resonant soft x-ray fluorescence at the Advanced Light Source to probe the electronic and geometric structure of novel materials. In the resonant process, a core electron is excited by a photon whose energy is near the core binding energy. In this energy regime the absorption and emission processes are coupled, and this coupling manifests itself in several ways. In boron nitride (BN), the resonant emission spectra reflect the influence of a ``spectator`` electron in an unoccupied excitonic state. The resonant emission can be used to distinguish between the various bulk phases of BN, and can also be used to probe the electronic structure of a monolayer of BN buried in a bulk environment, where it is inaccessible to electron spectroscopies. For highly-oriented pyrolytic graphite (HOPG) a coherent absorption-emission process takes place in the resonant regime, whereby crystalline momentum is conserved between the core excited electron and the valence hole which remains after emission.

  13. Counter tube window and X-ray fluorescence analyzer study

    NASA Technical Reports Server (NTRS)

    Hertel, R.; Holm, M.

    1973-01-01

    A study was performed to determine the best design tube window and X-ray fluorescence analyzer for quantitative analysis of Venusian dust and condensates. The principal objective of the project was to develop the best counter tube window geometry for the sensing element of the instrument. This included formulation of a mathematical model of the window and optimization of its parameters. The proposed detector and instrument has several important features. The instrument will perform a near real-time analysis of dust in the Venusian atmosphere, and is capable of measuring dust layers less than 1 micron thick. In addition, wide dynamic measurement range will be provided to compensate for extreme variations in count rates. An integral pulse-height analyzer and memory accumulate data and read out spectra for detail computer analysis on the ground.

  14. Using X-ray Fluorescence to Date Petroglyphs

    NASA Astrophysics Data System (ADS)

    McNeil, James

    2009-10-01

    Petroglyphs were created by ancient peoples of the Colorado Plateau who pecked figures of cultural or religious significance into the desert varnish, the ubiquitous dark patina covering the rock surfaces of the region. Manganese (Mn) is a significant elemental component of desert varnish that is often at trace levels in the substrate rock. As such, F. Lytle has shown that under certain conditions, it may be possible to estimate the age of petroglpyhs using Mn levels. In this work we use x-ray fluorescence to measure Mn levels in the desert varnish of petroglyphs and then use dated graffiti to attempt to calibrate the Mn level with age. Preliminary results from petroglyph panels in eastern Utah will be presented.

  15. X-Ray Fluorescence Microscopy for Investigation of Archival Tissues

    PubMed Central

    Paunesku, T.; Wanzer, M. B.; Kirillova, E. N.; Muksinova, K. N.; Revina, V. S.; Romanov, S. A.; Lyubchansky, E. R.; Grosche, B.; Birschwilks, M.; Vogt, S.; Finney, L.; Woloschak, G. E.

    2013-01-01

    Several recent efforts in radiation biology community worldwide have amassed records and archival tissues from animals exposed to different radionuclides and external beam irradiation. In most cases, these samples come from life-long studies on large animal populations conducted in national laboratories and equivalent institutions throughout Europe, North America, and Japan. While many of these tissues were used for histopathological analyses, much more information may still be obtained from these samples. A new technique suitable for imaging of these tissues is X-Ray Fluorescence Microscopy (XFM). Following development of third generation synchrotrons, XFM has emerged as an ideal technique for study of metal content, speciation, and localization in cells, tissues and organs. Here we review some of the recent XFM literature pertinent to tissue sample studies and present examples of XFM data obtained from tissue sections of beagle dog samples which show that the quality of archival tissues allows XFM investigation. PMID:22951477

  16. Gold nephropathy: tissue analysis by X-ray fluorescent spectroscopy.

    PubMed

    Viol, G W; Minielly, J A; Bistricki, T

    1977-12-01

    Three patients developed proteinuria following gold therapy for rheumatoid arthritis. The clinical syndrome was a self-limiting proteinuria with normal renal function. By light and electron microscopic appearances the renal lesion was an epimembranous deposit form of membranous glomerulopathy. Immunofluorescent study showed granular deposits of IgG and C3 complement along glomerular basement membranes. By X-ray fluorescent spectroscopic examination, gold was seen to be present within the proximal convoluted tubular cells but was not identified in the glomerular subepithelial deposits. These findings are consistent with an immune-complex form of glomerulopathy in which gold is neither the antigen nor a hapten in the glomerular deposits, and they suggest the hypothesis that antibodies to tubular epithelial antigens induced by gold therapy may be a causative factor in the renal disease associated with gold therapy in rheumatoid arthritis. PMID:412488

  17. Comparative studies of X-ray images and fluorescence images of the same specimens

    NASA Astrophysics Data System (ADS)

    Majima, T.; Tomie, T.; Shimizu, H.

    2003-03-01

    A flash contact soft x-ray microscope using laser-induced plasma as a flash x-ray source is a practical instrument for observation of living organisms in water [1-4]. As previously reported we developed a tabletop flash contact soft x-ray microscope System [3]. In this System, x-ray images are given as whole projection of the specimens on the PMMA membrane. This causes us some complexity for understanding the x-ray images. It is necessary to attribute features in the x-ray images to sub-cellular structures of the specimen. For this purpose we have developed a new sample holder, where specimens are observable with a fluorescence microscope just before x-ray exposure. Fluorescence images of onion epidermal cells stained by DAPI and x-ray images of the same specimens are compared.

  18. Soil characterization by energy dispersive X-ray fluorescence: sampling strategy for in situ analysis.

    PubMed

    Custo, Graciela; Boeykens, Susana; Dawidowski, L; Fox, L; Gómez, D; Luna, F; Vázquez, Cristina

    2005-07-01

    This work describes a sampling strategy that will allow the use of portable EDXRF (energy dispersive X-ray fluorescence) instruments for "in situ" soil analysis. The methodology covers a general approach to planning field investigations for any type of environmental studies and it was applied for a soil characterization study in the zone of Campana, Argentina, by evaluating data coming from an EDXRF spectrometer with a radioisotope excitation source. Simulating non-treated sampled as "in situ" samples and a soil characterization for Campana area was intended. "In situ" EDXRF methodology is a powerful analytical modality with the advantage of providing data immediately, allowing a fast general screening of the soil composition. PMID:16038489

  19. Azimuthal anisotropy of the scattered radiation in grazing incidence X-ray fluorescence

    SciTech Connect

    Das, Gangadhar Tiwari, M. K.; Singh, A. K.; Ghosh, Haranath

    2015-06-24

    The Compton and elastic scattering radiations are the major contributor to the spectral background of an x-ray fluorescence spectrum, which eventually limits the element detection sensitivities of the technique to µg/g (ppm) range. In the present work, we provide a detail mathematical descriptions and show that how polarization properties of the synchrotron radiation influence the spectral background in the x-ray fluorescence technique. We demonstrate our theoretical understandings through experimental observations using total x-ray fluorescence measurements on standard reference materials. Interestingly, the azimuthal anisotropy of the scattered radiation is shown to have a vital role on the significance of the x-ray fluorescence detection sensitivities.

  20. Total-reflection X-ray fluorescence analysis using special X-ray sources

    NASA Astrophysics Data System (ADS)

    Wobrauschek, P.; Kregsamer, P.; Ladisich, W.; Rieder, R.; Streli, C.

    1993-02-01

    The parameter variations of exciting radiation, like spectral distribution, intensity, brilliance, polarization and the phenomenon of X-ray total reflection, leads to improved lower limits of detection (LLD) in XRF. Observations and results from experiments performed with different X-ray tubes such as fine focus Cu and Mo anodes, a specially designed Au anode operated with 100 kV and high power rotating anodes are reported. Results from measurements with monochromatic X-rays tuned with a multilayer structure as well as the use of polarized X-rays from the synchrotron will be shown. All developed measuring devices will be described in terms of their recent design features showing the possible geometric arrangements denned by the beam-reflector-detector position. The extrapolated detection limits for the K-shell excitation of rare earth elements are in the region of 0.3 ng, for medium Z elements in the pg range and for optimized conditions, with a rotating Cu anode, 170 fg for Mn are achieved corresponding to the pg g -1 (ppt) concentration level.

  1. Fast X-Ray Fluorescence Microtomography of Hydrated Biological Samples

    PubMed Central

    Lombi, Enzo; de Jonge, Martin D.; Donner, Erica; Kopittke, Peter M.; Howard, Daryl L.; Kirkham, Robin; Ryan, Chris G.; Paterson, David

    2011-01-01

    Metals and metalloids play a key role in plant and other biological systems as some of them are essential to living organisms and all can be toxic at high concentrations. It is therefore important to understand how they are accumulated, complexed and transported within plants. In situ imaging of metal distribution at physiological relevant concentrations in highly hydrated biological systems is technically challenging. In the case of roots, this is mainly due to the possibility of artifacts arising during sample preparation such as cross sectioning. Synchrotron x-ray fluorescence microtomography has been used to obtain virtual cross sections of elemental distributions. However, traditionally this technique requires long data acquisition times. This has prohibited its application to highly hydrated biological samples which suffer both radiation damage and dehydration during extended analysis. However, recent advances in fast detectors coupled with powerful data acquisition approaches and suitable sample preparation methods can circumvent this problem. We demonstrate the heightened potential of this technique by imaging the distribution of nickel and zinc in hydrated plant roots. Although 3D tomography was still impeded by radiation damage, we successfully collected 2D tomograms of hydrated plant roots exposed to environmentally relevant metal concentrations for short periods of time. To our knowledge, this is the first published example of the possibilities offered by a new generation of fast fluorescence detectors to investigate metal and metalloid distribution in radiation-sensitive, biological samples. PMID:21674049

  2. Fast x-ray fluorescence microtomography of hydrated biological samples.

    PubMed

    Lombi, Enzo; de Jonge, Martin D; Donner, Erica; Kopittke, Peter M; Howard, Daryl L; Kirkham, Robin; Ryan, Chris G; Paterson, David

    2011-01-01

    Metals and metalloids play a key role in plant and other biological systems as some of them are essential to living organisms and all can be toxic at high concentrations. It is therefore important to understand how they are accumulated, complexed and transported within plants. In situ imaging of metal distribution at physiological relevant concentrations in highly hydrated biological systems is technically challenging. In the case of roots, this is mainly due to the possibility of artifacts arising during sample preparation such as cross sectioning. Synchrotron x-ray fluorescence microtomography has been used to obtain virtual cross sections of elemental distributions. However, traditionally this technique requires long data acquisition times. This has prohibited its application to highly hydrated biological samples which suffer both radiation damage and dehydration during extended analysis. However, recent advances in fast detectors coupled with powerful data acquisition approaches and suitable sample preparation methods can circumvent this problem. We demonstrate the heightened potential of this technique by imaging the distribution of nickel and zinc in hydrated plant roots. Although 3D tomography was still impeded by radiation damage, we successfully collected 2D tomograms of hydrated plant roots exposed to environmentally relevant metal concentrations for short periods of time. To our knowledge, this is the first published example of the possibilities offered by a new generation of fast fluorescence detectors to investigate metal and metalloid distribution in radiation-sensitive, biological samples. PMID:21674049

  3. Flow method and apparatus for screening chemicals using micro x-ray fluorescence

    DOEpatents

    Warner, Benjamin P.; Havrilla, George J.; Miller, Thomasin C.; Lewis, Cris; Mahan, Cynthia A.; Wells, Cyndi A.

    2009-04-14

    Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow-separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.

  4. Flow method and apparatus for screening chemicals using micro x-ray fluorescence

    DOEpatents

    Warner, Benjamin P.; Havrilla, George J.; Miller, Thomasin C.; Lewis, Cris; Mahan, Cynthia A.; Wells, Cyndi A.

    2011-04-26

    Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.

  5. X-Ray Diffraction and Fluorescence Measurements for In Situ Planetary Instruments

    NASA Astrophysics Data System (ADS)

    Hansford, G.; Hill, K. S.; Talboys, D.; Vernon, D.; Ambrosi, R.; Bridges, J.; Hutchinson, I.; Marinangeli, L.

    2011-12-01

    The ESA/NASA ExoMars mission, due for launch in 2018, has a combined X-ray fluorescence/diffraction instrument, Mars-XRD, as part of the onboard analytical laboratory. The results of some XRF (X-ray fluorescence) and XRD (X-ray diffraction) tests using a laboratory chamber with representative performance are reported. A range of standard geological reference materials and analogues were used in these tests. The XRD instruments are core components of the forthcoming NASA Mars Science Laboratory (MSL) and ESA/NASA ExoMars missions and will provide the first demonstrations of the capabilities of combined XRD/XRF instrumentation in situ on an extraterrestrial planetary surface. The University of Leicester team is part of the Italy-UK collaboration that is responsible for building the ExoMars X-ray diffraction instrument, Mars-XRD [1,2]. Mars-XRD incorporates an Fe-55 radioisotope source and three fixed-position charge-coupled devices (CCDs) to simultaneously acquire an X-ray fluorescence spectrum and a diffraction pattern providing a measurement of both elemental and mineralogical composition. The CCDs cover an angular range of 2θ = 6° to 73° enabling the analysis of a wide range of geologically important minerals including phyllosilicates, feldspars, oxides, carbonates and evaporites. The identification of hydrous minerals may help identify past Martian hydrothermal systems capable of preserving traces of life. Here we present some initial findings from XRF and XRD tests carried out at the University of Leicester using an Fe-55 source and X-ray sensitive CCD. The XRF/XRD test system consists of a single CCD on a motorised arm, an Fe-55 X-ray source, a collimator and a sample table which approximately replicate the reflection geometry of the Mars-XRD instrument. It was used to test geological reference standard materials and Martian analogues. This work was funded by the Science and Technology Facilities Council, UK. References [1] Marinangeli, L., Hutchinson, I

  6. High-throughput screening with micro-x-ray fluorescence

    SciTech Connect

    Havrilla, George J.; Miller, Thomasin C.

    2005-06-15

    Micro-x-ray fluorescence (MXRF) is a useful characterization tool for high-throughput screening of combinatorial libraries. Due to the increasing threat of use of chemical warfare (CW) agents both in military actions and against civilians by terrorist extremists, there is a strong push to improve existing methods and develop means for the detection of a broad spectrum of CW agents in a minimal amount of time to increase national security. This paper describes a combinatorial high-throughput screening technique for CW receptor discovery to aid in sensor development. MXRF can screen materials for elemental composition at the mesoscale level (tens to hundreds of micrometers). The key aspect of this work is the use of commercial MXRF instrumentation coupled with the inherent heteroatom elements within the target molecules of the combinatorial reaction to provide rapid and specific identification of lead species. The method is demonstrated by screening an 11-mer oligopeptide library for selective binding of the degradation products of the nerve agent VX. The identified oligopeptides can be used as selective molecular receptors for sensor development. The MXRF screening method is nondestructive, requires minimal sample preparation or special tags for analysis, and the screening time depends on the desired sensitivity.

  7. Inorganic chemical investigation by x-ray fluorescence analysis: The Viking Mars Lander

    USGS Publications Warehouse

    Toulmin, P.; Baird, A.K.; Clark, B. C.; Keil, Klaus; Rose, H.J.

    1973-01-01

    The inorganic chemical investigation added in August 1972 to the Viking Lander scientific package will utilize an energy-dispersive X-ray fluorescence spectrometer in which four sealed, gas-filled proportional counters will detect X-rays emitted from samples of the Martian surface materials irradiated by X-rays from radioisotope sources (55Fe and 109Cd). The output of the proportional counters will be subjected to pulse-height analysis by an on-board step-scanning single-channel analyzer with adjustable counting periods. The data will be returned to Earth, via the Viking Orbiter relay system, and the spectra constructed, calibrated, and interpreted here. The instrument is inside the Lander body, and samples are to be delivered to it by the Viking Lander Surface Sampler. Calibration standards are an integral part of the instrument. The results of the investigation will characterize the surface materials of Mars as to elemental composition with accuracies ranging from a few tens of parts per million (at the trace-element level) to a few percent (for major elements) depending on the element in question. Elements of atomic number 11 or less are determined only as a group, though useful estimates of their individual abundances maybe achieved by indirect means. The expected radiation environment will not seriously hamper the measurements. Based on the results, inferences can be drawn regarding (1) the surface mineralogy and lithology; (2) the nature of weathering processes, past and present, and the question of equilibrium between the atmosphere and the surface; and (3) the extent and type of differentiation that the planet has undergone. The Inorganic Chemical Investigation supports and is supported by most other Viking Science investigations. ?? 1973.

  8. Gold nanoclusters as contrast agents for fluorescent and X-ray dual-modality imaging.

    PubMed

    Zhang, Aili; Tu, Yu; Qin, Songbing; Li, Yan; Zhou, Juying; Chen, Na; Lu, Qiang; Zhang, Bingbo

    2012-04-15

    Multimodal imaging technique is an alternative approach to improve sensitivity of early cancer diagnosis. In this study, highly fluorescent and strong X-ray absorption coefficient gold nanoclusters (Au NCs) are synthesized as dual-modality imaging contrast agents (CAs) for fluorescent and X-ray dual-modality imaging. The experimental results show that the as-prepared Au NCs are well constructed with ultrasmall sizes, reliable fluorescent emission, high computed tomography (CT) value and fine biocompatibility. In vivo imaging results indicate that the obtained Au NCs are capable of fluorescent and X-ray enhanced imaging.

  9. Energy response calibration of photon-counting detectors using X-ray fluorescence: a feasibility study

    PubMed Central

    Cho, H-M; Ding, H; Ziemer, BP; Molloi, S

    2014-01-01

    Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using X-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for X-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm2 in detection area. The angular dependence of X-ray fluorescence and scatter background was investigated by varying the detection angle from 20° to 170° with respect to the beam direction. The effects of the detector material, shape, and size on the recorded X-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of X-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120° with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of X-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic X-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the X-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory. PMID:25369288

  10. Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study.

    PubMed

    Cho, H-M; Ding, H; Ziemer, B P; Molloi, S

    2014-12-01

    Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using x-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for x-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm(2) in detection area. The angular dependence of x-ray fluorescence and scatter background was investigated by varying the detection angle from 20° to 170° with respect to the beam direction. The effects of the detector material, shape, and size on the recorded x-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of x-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120° with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of x-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic x-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the x-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory.

  11. X-ray fluorescence analyzers for investigating postmediaeval pottery from Southern Moravia.

    PubMed

    Trojek, Tomás; Hlozek, Matin; Cechák, Tomás; Musílek, Ladislav

    2010-01-01

    This paper deals with an investigation of ceramic archaeological finds with the use of in-situ X-ray fluorescence analysis. Firstly, three configurations of X-ray fluorescence analyzers constructed and used at the Czech Technical University in Prague are described and compared for use in a non-destructive survey of siliceous materials. Detection limits, depth of analysis, the relation of the analyzed area, the homogeneity of the samples, and variations in the element concentrations are discussed. Secondly, many shards of postmediaeval pottery from Southern Moravia are analyzed with X-ray fluorescence analysis and some of them also with electron microprobe analysis. Selected results are described.

  12. Application of confocal X-ray fluorescence micro-spectroscopy to the investigation of paint layers.

    PubMed

    Sun, Tianxi; Liu, Zhiguo; Wang, Guangfu; Ma, Yongzhong; Peng, Song; Sun, Weiyuan; Li, Fangzuo; Sun, Xuepeng; Ding, Xunliang

    2014-12-01

    A confocal micro X-ray fluorescence (MXRF) spectrometer based on polycapillary X-ray optics was used for the identification of paint layers. The performance of the confocal MXRF was studied. Multilayered paint fragments of a car were analyzed nondestructively to demonstrate that this confocal MXRF instrument could be used in the discrimination of the various layers in multilayer paint systems.

  13. Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube

    SciTech Connect

    Kayser, Y.; Błachucki, W.; Dousse, J.-Cl.; Hoszowska, J.; Neff, M.; Romano, V.

    2014-04-15

    The high-resolution von Hamos bent crystal spectrometer of the University of Fribourg was upgraded with a focused X-ray beam source with the aim of performing micro-sized X-ray fluorescence (XRF) measurements in the laboratory. The focused X-ray beam source integrates a collimating optics mounted on a low-power micro-spot X-ray tube and a focusing polycapillary half-lens placed in front of the sample. The performances of the setup were probed in terms of spatial and energy resolution. In particular, the fluorescence intensity and energy resolution of the von Hamos spectrometer equipped with the novel micro-focused X-ray source and a standard high-power water-cooled X-ray tube were compared. The XRF analysis capability of the new setup was assessed by measuring the dopant distribution within the core of Er-doped SiO{sub 2} optical fibers.

  14. Synchrotron Radiation X-Ray Spectroscopy for Investigations of Intracellular Metallointercalators: X-Ray Fluorescence Imaging and X-Ray Absorption Spectroscopy

    NASA Astrophysics Data System (ADS)

    Dillon, Carolyn T.

    In an effort to determine the therapeutic feasibility of DNA metallointercalators as potential anticancer drugs it is important to confirm that they are capable of targeting DNA in cancer cells or tumours - as is the intended purpose of their design. Microprobe synchrotron radiation X-ray fluorescence (micro-SRXRF) spectroscopy is an ideal technique for investigating the cellular uptake and distribution of metallointercalators. The technique is capable of submicron elemental imaging so that samples as small as individual cells (~10 μm diameter), and the features within them, can be resolved. Consequently, the technique can ascertain whether intracellular metallointercalators colocalise with DNA; namely, in the nucleus during interphase or at the chromosomes during middle prophase to late anaphase. Metals, such as those commonly incorporated into metallointercalators (e.g., Cr, Ni, Co, Pd, Pt, Ru, Rh), are often naturally present in negligible quantities in cancer cells. This fact, together with their higher atomic number, Z, makes them ideal for direct probing using hard X-ray microprobes (as discussed in Sect. 11.2). There is no need for the incorporation of fluorescent tracker dyes or radioactive labels into their chemical structure. This is advantageous since it is unknown whether such chemical modifications alter the uptake kinetics of the metallointercalator [1, 2].

  15. A 30 nm-resolution hard X-ray microscope with X-ray fluorescence mapping capability at BSRF.

    PubMed

    Yuan, Qingxi; Zhang, Kai; Hong, Youli; Huang, Wanxia; Gao, Kun; Wang, Zhili; Zhu, Peiping; Gelb, Jeff; Tkachuk, Andrei; Hornberger, Benjamin; Feser, Michael; Yun, Wenbing; Wu, Ziyu

    2012-11-01

    A full-field transmission X-ray microscope (TXM) operating continuously from 5 keV to 12 keV with fluorescence mapping capability has been designed and constructed at the Beijing Synchrotron Radiation Facility, a first-generation synchrotron radiation facility operating at 2.5 GeV. Spatial resolution better than 30 nm has been demonstrated using a Siemens star pattern in both absorption mode and Zernike phase-contrast mode. A scanning-probe mode fluorescence mapping capability integrated with the TXM has been shown to provide 50 p.p.m. sensitivity for trace elements with a spatial resolution (limited by probing beam spot size) of 20 µm. The optics design, testing of spatial resolution and fluorescence sensitivity are presented here, including performance measurement results. PMID:23093765

  16. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    NASA Astrophysics Data System (ADS)

    Dhara, Sangita; Misra, N. L.; Maind, S. D.; Kumar, Sanjukta A.; Chattopadhyay, N.; Aggarwal, S. K.

    2010-02-01

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 μL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO 3/HClO 4, mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1 σ) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  17. In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence

    NASA Technical Reports Server (NTRS)

    Sarrazin, P.; Blake, D.; Vaniman, D.; Chang, Sherwood (Technical Monitor)

    1996-01-01

    Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a

  18. Method for detecting binding events using micro-X-ray fluorescence spectrometry

    DOEpatents

    Warner, Benjamin P.; Havrilla, George J.; Mann, Grace

    2010-12-28

    Method for detecting binding events using micro-X-ray fluorescence spectrometry. Receptors are exposed to at least one potential binder and arrayed on a substrate support. Each member of the array is exposed to X-ray radiation. The magnitude of a detectable X-ray fluorescence signal for at least one element can be used to determine whether a binding event between a binder and a receptor has occurred, and can provide information related to the extent of binding between the binder and receptor.

  19. ISS Ammonia Leak Detection Through X-Ray Fluorescence

    NASA Technical Reports Server (NTRS)

    Camp, Jordan; Barthelmy, Scott; Skinner, Gerry

    2013-01-01

    Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge

  20. Development and applications of an epifluorescence module for synchrotron x-ray fluorescence microprobe imaging

    SciTech Connect

    Miller, Lisa M.; Smith, Randy J.; Ruppel, Meghan E.; Ott, Cassandra H.; Lanzirotti, Antonio

    2005-06-15

    Synchrotron x-ray fluorescence (XRF) microprobe is a valuable analysis tool for imaging trace element composition in situ at a resolution of a few microns. Frequently, epifluorescence microscopy is beneficial for identifying the region of interest. To date, combining epifluorescence microscopy with x-ray microprobe has involved analyses with two different microscopes. We report the development of an epifluorescence module that is integrated into a synchrotron XRF microprobe beamline, such that visible fluorescence from a sample can be viewed while collecting x-ray microprobe images simultaneously. This unique combination has been used to identify metal accumulation in Alzheimer's disease plaques and the mineral distribution in geological samples. The flexibility of this accessory permits its use on almost any synchrotron x-ray fluorescence microprobe beamline and applications in many fields of science can benefit from this technology.

  1. Element Mapping in Organic Samples Utilizing a Benchtop X-Ray Fluorescence Emission Tomography (XFET) System

    PubMed Central

    Groll, A.; George, J.; Vargas, P.; La Rivière, P.J.; Meng, L. J.

    2015-01-01

    X-ray fluorescence computed tomography (XFCT) is an emerging imaging modality that maps the three-dimensional distribution of elements, generally metals, in ex vivo specimens and potentially in living animals and humans. Building on our previous synchrotron-based work, we experimentally explored the use of a benchtop X-ray fluorescence computed tomography system for mapping trace-metal ions in biological samples. This system utilizes a scanning pencil-beam to stimulate the object and then relies on a detection system, with single or multiple slit apertures placed in front of position-sensitive X-ray detectors, to collect the fluorescence X-rays and to form 3-D elemental map without the need for tomographic imaging reconstruction. The technique was used to generate images of the elemental distributions of a triple-tube phantom and an osmium-stained zebrafish. PMID:26705368

  2. An X-ray refractive lens comprising two sections cut from a gramophone record for a portable total reflection X-ray fluorescence spectrometer

    NASA Astrophysics Data System (ADS)

    Kunimura, Shinsuke; Kawai, Jun

    2009-08-01

    An X-ray refractive lens is assembled from two sections cut from a gramophone record. The refractive lens is placed in a portable total reflection X-ray fluorescence (TXRF) spectrometer, and it is used for collimation of the incident X-ray beams. A TXRF spectrum measured with the refractive lens is compared with that measured with a waveguide. Compared with the refractive lens, the waveguide enhances the intensities of the X-rays illuminating an analyte. Therefore, fluorescent X-ray intensities increase when using the waveguide. On the other hand, the vertical angular divergence of the incident X-ray beams is smaller when using the refractive lens, and the smaller angular divergence results in a reduction of the scattering of the incident X-rays from a sample holder. Therefore, the spectral background is reduced when using the refractive lens, resulting in an increase of the signal to background ratios of the fluorescent X-rays. Detection limits for 3d transition metals obtained with the refractive lens are sub-nanograms to a few nanograms, and the detection limits are similar to those obtained with the waveguide.

  3. Attempt at Two-Dimensional Mapping of X-ray Fluorescence from Breast Cancer Tissue

    NASA Astrophysics Data System (ADS)

    Ando, Masami; Yamasaki, Katsuhito; Ohbayashi, Chiho; Esumi, Hiroyasu; Hyodo, Kazuyuki; Sugiyama, Hiroshi; Li, Gang; Maksimenko, Anton; Kawai, Toshiaki

    2005-07-01

    A world first two-dimensional mapping of X-ray fluorescence from an invasive papillary carcinoma containing three kinds of metal elements that by white radiation has been obtained. Carcinoma shows intense Ca K X-rays, while normal tissue including stroma, shows no such Ca X-ray signals within experimental precision, but even shows reasonable Fe and Zn K X-ray intensity. This has extremely good correspondence to an X-ray dark-field (X-DF) image taken using a Laue angular analyzer. This fact may suggest an idea that carcinoma may attract Ca atoms better than Fe and Zn atoms, which are involved more in normal tissue.

  4. Cryo X-ray microscope with flat sample geometry for correlative fluorescence and nanoscale tomographic imaging.

    PubMed

    Schneider, Gerd; Guttmann, Peter; Rehbein, Stefan; Werner, Stephan; Follath, Rolf

    2012-02-01

    X-ray imaging offers a new 3-D view into cells. With its ability to penetrate whole hydrated cells it is ideally suited for pairing fluorescence light microscopy and nanoscale X-ray tomography. In this paper, we describe the X-ray optical set-up and the design of the cryo full-field transmission X-ray microscope (TXM) at the electron storage ring BESSY II. Compared to previous TXM set-ups with zone plate condenser monochromator, the new X-ray optical layout employs an undulator source, a spherical grating monochromator and an elliptically shaped glass capillary mirror as condenser. This set-up improves the spectral resolution by an order of magnitude. Furthermore, the partially coherent object illumination improves the contrast transfer of the microscope compared to incoherent conditions. With the new TXM, cells grown on flat support grids can be tilted perpendicular to the optical axis without any geometrical restrictions by the previously required pinhole for the zone plate monochromator close to the sample plane. We also developed an incorporated fluorescence light microscope which permits to record fluorescence, bright field and DIC images of cryogenic cells inside the TXM. For TXM tomography, imaging with multi-keV X-rays is a straightforward approach to increase the depth of focus. Under these conditions phase contrast imaging is necessary. For soft X-rays with shrinking depth of focus towards 10nm spatial resolution, thin optical sections through a thick specimen might be obtained by deconvolution X-ray microscopy. As alternative 3-D X-ray imaging techniques, the confocal cryo-STXM and the dual beam cryo-FIB/STXM with photoelectron detection are proposed. PMID:22273540

  5. Monte Carlo simulation applied in total reflection x-ray fluorescence: Preliminary results

    SciTech Connect

    Meira, Luiza L. C.; Inocente, Guilherme F.; Vieira, Leticia D.; Mesa, Joel

    2013-05-06

    The X-ray Fluorescence (XRF) analysis is a technique for the qualitative and quantitative determination of chemical constituents in a sample. This method is based on detection of the characteristic radiation intensities emitted by the elements of the sample, when properly excited. A variant of this technique is the Total Reflection X-ray Fluorescence (TXRF) that utilizes electromagnetic radiation as excitation source. In total reflection of X-ray, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample support interface. Thus, there is a minimum angle of incidence at which no refracted beam exists and all incident radiation undergoes total reflection. In this study, we evaluated the influence of the energy variation of the beam of incident x-rays, using the MCNPX code (Monte Carlo NParticle) based on Monte Carlo method.

  6. On the viability of exploiting L-shell fluorescence for X-ray polarimetry

    NASA Technical Reports Server (NTRS)

    Weisskopf, M. C.; Sutherland, P. G.; Elsner, R. F.; Ramsey, B. D.

    1985-01-01

    It has been suggested that one may build an X-ray polarimeter by exploiting the polarization dependence of the angular distribution of L-shell fluorescence photons. In this paper the sensitivity of this approach to polarimetry is examined theoretically. The calculations are applied to several detection schemes using imaging proportional counters that would have direct application in X-ray astronomy. It is found, however, that the sensitivity of this method for measuring X-ray polarization is too low to be of use for other than laboratory applications.

  7. Age Determination by X-ray Fluorescence Rubidium-Strontium Ratio Measurement in Lepidolite.

    PubMed

    Herzog, L F

    1960-07-29

    X-ray fluorescence analysis of several lepidolites whose rubidium and strontium concentrations had already been determined by neutron activation and stable isotope dilution, or both, indicates that this technique can be used for rapid nondestructive reconnaissance rubidiumstrontium studies, and that an x-ray analysis method comparable in accuracy to isotope dilution can probably be developed for dating Precambrian lepidolites, as the simple technique presently used has many obvious possibilities for improvement.

  8. An X-ray fluorescence spectrometer and its applications in materials studies

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Han, K. S.

    1977-01-01

    An X-ray fluorescence system based on a Co(57) gamma-ray source has been developed. The system was used to calculate the atomic percentages of iron implanted in titanium targets. Measured intensities of Fe (k-alpha + k-beta) and Ti (k-alpha + k-beta) X-rays from the Fe-Ti targets are in good agreement with the calculated values based on photoelectric cross sections of Ti and Fe for the Co(57) gamma rays.

  9. Apollo 16 geochemical X-ray fluorescence experiment: Preliminary report

    NASA Technical Reports Server (NTRS)

    Adler, I.; Trombka, J.; Gerard, J.; Lowman, P.; Schmadebeck, R.; Blodgett, H.; Eller, E.; Yin, L.; Lamothe, R.; Osswald, G.

    1972-01-01

    The lunar surface was mapped with respect to Mg, Al, and Si, as Al/Si and Mg/Si ratios along the projected ground tracks swept out by the orbiting Apollo 16 spacecraft. The results confirm the observations made during the Apollo 15 flight and provide data for a number of features not covered before. The data are consistent with the idea that the moon has a widespread differentiated crust (the highlands). The Al/Si and Mg/Si chemical ratios correspond to that for anorthositic gabbro through gabbroic anorthosites or feldspathic basalts. The X-ray results suggest the occurrence of this premare crust or material similar to it as the Descartes landing site.

  10. Portable total reflection x-ray fluorescence analysis in the identification of unknown laboratory hazards

    SciTech Connect

    Liu, Ying Imashuku, Susumu; Sasaki, Nobuharu; Ze, Long; Kawai, Jun; Takano, Shotaro; Sohrin, Yoshiki; Seki, Hiroko; Miyauchi, Hiroya

    2014-05-15

    In this study, a portable total reflection x-ray fluorescence (TXRF) spectrometer was used to analyze unknown laboratory hazards that precipitated on exterior surfaces of cooling pipes and fume hood pipes in chemical laboratories. With the aim to examine the accuracy of TXRF analysis for the determination of elemental composition, analytical results were compared with those of wavelength-dispersive x-ray fluorescence spectrometry, scanning electron microscope and energy-dispersive x-ray spectrometry, energy-dispersive x-ray fluorescence spectrometry, inductively coupled plasma atomic emission spectrometry, x-ray diffraction spectrometry (XRD), and x-ray photoelectron spectroscopy (XPS). Detailed comparison of data confirmed that the TXRF method itself was not sufficient to determine all the elements (Z > 11) contained in the samples. In addition, results suggest that XRD should be combined with XPS in order to accurately determine compound composition. This study demonstrates that at least two analytical methods should be used in order to analyze the composition of unknown real samples.

  11. Portable x-ray fluorescence spectrometer for environmental monitoring of inorganic pollutants

    NASA Technical Reports Server (NTRS)

    Thornton, Michael G. (Inventor); Clark, III, Benton C. (Inventor)

    1991-01-01

    A portable x-ray fluorescence spectrometer has a portable sensor unit containing a battery, a high voltage power supply, an x-ray tube which produces a beam x-ray radiation directed toward a target sample, and a detector for fluorescent x-rays produced by the sample. If a silicon-lithium detector is used, the sensor unit also contains either a thermoelectric or thermochemical cooler, or a small dewar flask containing liquid nitrogen to cool the detector. A pulse height analyzer (PHA) generates a spectrum of data for each sample consisting of the number of fluorescent x-rays detected as a function of their energy level. The PHA can also store spectrum data for a number of samples in the field. A processing unit can be attached to the pulse height analyzer to upload and analyze the stored spectrum data for each sample. The processing unit provides a graphic display of the spectrum data for each sample, and provides qualitative and/or quantitative analysis of the elemental composition of the sample by comparing the peaks in the sample spectrum against known x-ray energies for various chemical elements. An optional filtration enclosure can be used to filter particles from a sample suspension, either in the form of a natural suspension or a chemically created precipitate. The sensor unit is then temporarily attached to the filtration unit to analyze the particles collected by the filter medium.

  12. Design and characterization of a pulsed x-ray source for fluorescent lifetime measurements

    SciTech Connect

    Blankespoor, S.C. |

    1993-12-01

    To search for new, fast, inorganic scintillators, the author and his colleagues have developed a bench-top pulsed x-ray source for determining fluorescent lifetimes and wavelengths of compounds in crystal or powdered form. This source uses a light-excited x-ray tube which produces x-rays when light from a laser diode strikes its photocathode. The x-ray tube has a tungsten anode, a beryllium exit window, a 30 kV maximum tube bias, and a 50 HA maximum average cathode current. The laser produces 3 {times} 10{sup 7} photons at 650 nm per {approximately}100 ps pulse, with up to 10{sup 7} pulses/sec. The time spread for the laser diode, x-ray tube, and a microchannel plate photomultiplier tube is less than 120 ps fwhm. The mean x-ray photon energy, at tube biases of 20, 25, and 30 kV, is 9.4, 10.3, and 11.1 keV, respectively. They measured 140, 230, and 330 x-ray photons per laser diode pulse per steradian at tube biases of 20, 25, and 30 kV, respectively. Background x-rays due to dark current occur at a rate of 1 {times} 10{sup 6} and 3 {times} 10{sup 6} photons/sec/steradian at tube biases of 25 and 30 kV, respectively. Data characterizing the x-ray output with an aluminum filter in the x-ray beam are also presented.

  13. Development of a micro-X-ray fluorescence system based on polycapillary X-ray optics for non-destructive analysis of archaeological objects

    NASA Astrophysics Data System (ADS)

    Cheng, Lin; Ding, Xunliang; Liu, Zhiguo; Pan, Qiuli; Chu, Xuelian

    2007-08-01

    A new micro-X-ray fluorescence (micro-XRF) system based on rotating anode X-ray generator and polycapillary X-ray optics has been set up in XOL Lab, BNU, China, in order to be used for analysis of archaeological objects. The polycapillary X-ray optics used here can focus the primary X-ray beam down to tens of micrometers in diameter that allows for non-destructive and local analysis of sub-mm samples with minor/trace level sensitivity. The analytical characteristics and potential of this micro-XRF system in archaeological research are discussed. Some described uses of this instrument include studying Chinese ancient porcelain.

  14. Synchrotron X-ray Fluorescence Microtomography in Geo-, Cosmo-, and Bio- chemistry

    NASA Astrophysics Data System (ADS)

    Lanzirotti, A.; Sutton, S. R.; Rivers, M.; Tappero, R.

    2009-05-01

    Synchrotron-based X-ray fluorescence computed microtomography (xrfCMT) is a unique method for imaging major and trace element distributions within natural materials nondestructively and with high spatial resolution. The technique is particularly useful in imaging and quantifying elemental abundance in small objects that may be too precious or too difficult to section, or in the analysis of materials in which sectioning may potentially alter elemental distributions. This presentation will highlight how this technique is being applied at beamlines X26A and X27A at the National Synchrotron Light Source (Brookhaven National Laboratory) and at 13-ID at the Advanced Photon Source (Argonne National Laboratory). These instruments utilize 1-10 μm diameter focused, monochromatic X-ray beams to non- destructively measure x-ray fluorescence from a sample as it is translated and rotated within the beam. The resultant fluorescence intensities are then reconstructed as either two-dimensional cross sectional or three- dimensional elemental distribution using a fast fourier transform based computational reconstruction algorithm. Reconstruction of multi-elemental distributions at concentrations down to approximately 1 μg g-1 (element dependent) can be obtained. By collecting and storing full energy dispersive spectra from a multi-channel analyzer for every pixel (rather than regions of interest), it is possible to evaluate a reconstructed spectrum within the object for more robust elemental analysis. For high density matrices in particular, corrections are necessary to account for x-ray absorption by the object of both incoming X-rays and outgoing fluorescent X-rays. These effects limit the size of objects and elements that can be imaged; however reasonable corrections can be made if an estimate of linear absorption coefficient through the material is made. It is also possible to couple fluorescence tomography with microbeam x-ray absorption and diffraction analysis. When coupled

  15. Determination of trace elements in Syrian medicinal plants and their infusions by energy dispersive X-ray fluorescence and total reflection X-ray fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Khuder, A.; Sawan, M. Kh.; Karjou, J.; Razouk, A. K.

    2009-07-01

    X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise ( Anisum vulgare), licorice root ( Glycyrrhiza glabra), and white wormwood ( Artemisia herba-alba).

  16. X-ray fluorescence spectrometry for high throughput analysis of atmospheric aerosol samples: The benefits of synchrotron X-rays

    NASA Astrophysics Data System (ADS)

    Bukowiecki, Nicolas; Lienemann, Peter; Zwicky, Christoph N.; Furger, Markus; Richard, Agnes; Falkenberg, Gerald; Rickers, Karen; Grolimund, Daniel; Borca, Camelia; Hill, Matthias; Gehrig, Robert; Baltensperger, Urs

    2008-09-01

    The determination of trace element mass concentrations in ambient air with a time resolution higher than one day represents an urgent need in atmospheric research. It involves the application of a specific technique both for the aerosol sampling and the subsequent analysis of the collected particles. Beside the intrinsic sensitivity of the analytical method, the sampling interval and thus the quantity of collected material that is available for subsequent analysis is a major factor driving the overall trace element detection power. This is demonstrated for synchrotron radiation X-ray fluorescence spectrometry (SR-XRF) of aerosol samples collected with a rotating drum impactor (RDI) in hourly intervals and three particle size ranges. The total aerosol mass on the 1-h samples is in the range of 10 µg. An experimental detection of the nanogram amounts of trace elements with the help of synchrotron X-rays was only achievable by the design of a fit-for-purpose sample holder system, which considered the boundary conditions both from particle sampling and analysis. A 6-µm polypropylene substrate film has evolved as substrate of choice, due to its practical applicability during sampling and its suitable spectroscopic behavior. In contrast to monochromatic excitation conditions, the application of a 'white' beam led to a better spectral signal-to-background ratio. Despite the low sample mass, a counting time of less than 30 s per 1-h aerosol sample led to sufficient counting statistics. Therefore the RDI-SR-XRF method represents a high-throughput analysis procedure without the need for any sample preparation. The analysis of a multielemental mass standard film by SR-XRF, laboratory-based wavelength-dispersive XRF spectrometry and laboratory-based micro XRF spectrometry showed that the laboratory-based methods were no alternatives to the SR-XRF method with respect to sensitivity and efficiency of analysis.

  17. Laboratory studies into the effect of regolith on planetary X-ray fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Näränen, Jyri; Parviainen, Hannu; Muinonen, Karri; Carpenter, James; Nygård, Kim; Peura, Marko

    2008-12-01

    In the analysis of X-ray fluorescence spectra from planetary surfaces, it is traditionally assumed that the observed surface is a plane-parallel, smooth, and homogeneous medium. The spectral and spatial resolutions of the instruments that have been used to measure X-ray emission from planetary surfaces to date have been such that this has been a reasonable assumption, but a new generation of X-ray spectrometers will provide enhanced spectral and spatial resolutions when compared with previous instrumentation. In light of these improvements in performance, it is important to assess how the requirements on the methodology of analysis of spectra may change when the surface is considered as a regolith. At other wavelengths, varying physical properties of planetary regoliths, such as the packing density, are known to have an effect on the observed signal as a function of viewing geometry. In this paper, the results from laboratory X-ray fluorescence measurements of regolith analogue materials at different viewing geometries are presented. Characteristic properties of the regolith such as particle sizes and packing density are found to affect the measured elemental line ratios. A semiempirical function is introduced as a tool for fitting fluorescent line intensity dependences as a function of viewing geometry. The importance of the results is discussed and recommendations are made for the future analysis of planetary X-ray fluorescence data.

  18. Quantitative measurement of binary liquid distributions using multiple-tracer x-ray fluorescence and radiography

    SciTech Connect

    Halls, Benjamin R.; Meyer, Terrence R.; Kastengren, Alan L.

    2015-01-01

    The complex geometry and large index-of-refraction gradients that occur near the point of impingement of binary liquid jets present a challenging environment for optical interrogation. A simultaneous quadruple-tracer x-ray fluorescence and line-of-sight radiography technique is proposed as a means of distinguishing and quantifying individual liquid component distributions prior to, during, and after jet impact. Two different pairs of fluorescence tracers are seeded into each liquid stream to maximize their attenuation ratio for reabsorption correction and differentiation of the two fluids during mixing. This approach for instantaneous correction of x-ray fluorescence reabsorption is compared with a more time-intensive approach of using stereographic reconstruction of x-ray attenuation along multiple lines of sight. The proposed methodology addresses the need for a quantitative measurement technique capable of interrogating optically complex, near-field liquid distributions in many mixing systems of practical interest involving two or more liquid streams.

  19. Laboratory verification of the lunar orbital X-ray fluorescence experiment - Initial results

    NASA Technical Reports Server (NTRS)

    Hubbard, N.; King, B.-S.

    1980-01-01

    The combined use of remote sensing and returned sample chemical data in lunar studies presumes a direct link between the two types of data. Laboratory experiments have demonstrated that within the precision of the lunar orbital X-ray fluorescence data there is a direct relationship between the fluorescence K-series X-radiation emitted from Mg, Al and Si in the surfaces of lunar soil samples and the concentrations of these elements in the bulk soil samples. This relationship encompasses both mare and terra soils. The degree of maturity is not an important variable for the existing orbital X-ray data. It is argued that these results are directly applicable to the lunar surface analyzed by the Apollo orbital X-ray fluorescence experiment.

  20. Analysis of eight argonne premium coal samples by X-ray fluorescence spectrometry

    USGS Publications Warehouse

    Evans, J.R.; Sellers, G.A.; Johnson, R.G.; Vivit, D.V.; Kent, J.

    1990-01-01

    X-ray fluorescence spectrometric methods were used in the analysis of eight Argonne Premium Coal Samples. Trace elements (Cr, Ni, Cu, Zn, Rb, Sr, Y, Zr, Nb, Ba, La, and Ce) in coal ash were determined by energy-dispersive X-ray fluorescence spectrometry; major elements (Na, Mg, Al, Si, P, S, K, Ca, Ti, Mn, and Fe) in coal ash and trace elements (Cl and P) in whole coal were determined by wavelength-dispersive X-ray fluorescence spectrometry. The results of this study will be used in a geochemical database compiled for these materials from various analytical techniques. The experimental XRF methods and procedures used to determine these major and trace elements are described.

  1. Calculating the X-Ray Fluorescence from the Planet Mercury Due to High-Energy Electrons

    NASA Technical Reports Server (NTRS)

    Burbine, T. H.; Trombka, J. I.; Bergstrom, P. M., Jr.; Christon, S. P.

    2005-01-01

    The least-studied terrestrial planet is Mercury due to its proximity to the Sun, which makes telescopic observations and spacecraft encounters difficult. Our lack of knowledge about Mercury should change in the near future due to the recent launching of MESSENGER, a Mercury orbiter. Another mission (BepiColombo) is currently being planned. The x-ray spectrometer on MESSENGER (and planned for BepiColombo) can characterize the elemental composition of a planetary surface by measuring emitted fluorescent x-rays. If electrons are ejected from an atom s inner shell by interaction with energetic particles such as photons, electrons, or ions, electrons from an outer shell can transfer to the inner shell. Characteristic x-rays are then emitted with energies that are the difference between the binding energy of the ion in its excited state and that of the ion in its ground state. Because each element has a unique set of energy levels, each element emits x-rays at a unique set of energies. Electrons and ions usually do not have the needed flux at high energies to cause significant x-ray fluorescence on most planetary bodies. This is not the case for Mercury where high-energy particles were detected during the Mariner 10 flybys. Mercury has an intrinsic magnetic field that deflects the solar wind, resulting in a bow shock in the solar wind and a magnetospheric cavity. Electrons and ions accelerated in the magnetosphere tend to follow its magnetic field lines and can impact the surface on Mercury s dark side Modeling has been done to determine if x-ray fluorescence resulting from the impact of high-energy electrons accelerated in Mercury's magnetosphere can be detected by MESSENGER. Our goal is to understand how much bulk chemical information can be obtained from x-ray fluorescence measurements on the dark side of Mercury.

  2. Application of X-ray fluorescence in an investigation of photographic heritage

    NASA Astrophysics Data System (ADS)

    Čechák, T.; Kopecká, I.; Trojek, T.; Štanzel, T.; Bártová, H.

    2015-11-01

    X-ray fluorescence analysis uses ionizing radiation to study the elemental composition of materials. It is widely used for many purposes, including studies of various cultural and historic relicts and objects of art. This paper summarizes our experience with X-ray fluorescence analysis and attenuated total reflectance Fourier transform infrared spectroscopy in investigating historical photographs by means of portable spectroscopic devices. The results of these measurements provide information about the composition of historical photographs and their toning. They can be used for comparing the processes used in fabricating the photographs, for assessing the quality of the paper and, in many cases, for information about how to repair damaged parts.

  3. Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom

    SciTech Connect

    Ren, Liqiang; Wu, Di; Li, Yuhua; Liu, Hong; Wang, Ge; Wu, Xizeng

    2014-03-15

    Purpose : X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosis and treatment is studied using a novel approach for three-dimensional (3D) x-ray fluorescence mapping (XFM) of gold nanoparticle (GNP)-loaded objects in a physical phantom at the technical level. Methods : All the theoretical analysis and experiments are conducted under the condition of using x-ray pencil beam and a compactly integrated x-ray spectrometer. The penetrability of the fluorescence x-rays from GNPs is first investigated by adopting a combination of BR12 with 70 mm/50 mm in thickness on the excitation/emission path to mimic the possible position of tumor goldin vivo. Then, a physical phantom made of BR12 is designed to translate in 3D space with three precise linear stages and subsequently the step by step XFM scanning is performed. The experimental technique named as background subtraction is applied to isolate the gold fluorescence from each spectrum obtained by the spectrometer. Afterwards, the attenuations of both the incident primary x-ray beam with energies beyond the gold K-edge energy (80.725 keV) and the isolated gold K{sub α} fluorescence x-rays (65.99 –69.80 keV) acquired after background subtraction are well calibrated, and finally the unattenuated K{sub α} fluorescence counts are used to realize mapping reconstruction and to describe the linear relationship between gold fluorescence counts and corresponding concentration of gold solutions. Results : The penetration results show that the goldK{sub α} fluorescence x-rays have sufficient penetrability for this phantom study, and the reconstructed mapping results indicate that both the spatial distribution and relative concentration of GNPs within the designed BR12 phantom

  4. X-RAY FLUORESCENCE ANALYSIS OF HANFORD LOW ACTIVITY WASTE SIMULANTS METHOD DEVELOPMENT

    SciTech Connect

    Jurgensen, A; David Missimer, D; Ronny Rutherford, R

    2007-08-08

    The x-ray fluorescence laboratory (XRF) in the Analytical Development Directorate (ADD) of the Savannah River National Laboratory (SRNL) was requested to develop an x-ray fluorescence spectrometry method for elemental characterization of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) pretreated low activity waste (LAW) stream to the LAW Vitrification Plant. The WTP is evaluating the potential for using XRF as a rapid turnaround technique to support LAW product compliance and glass former batching. The overall objective of this task was to develop an XRF analytical method that provides rapid turnaround time (<8 hours), while providing sufficient accuracy and precision to determine variations in waste.

  5. The MicroAnalysis Toolkit: X-ray Fluorescence Image Processing Software

    SciTech Connect

    Webb, S. M.

    2011-09-09

    The MicroAnalysis Toolkit is an analysis suite designed for the processing of x-ray fluorescence microprobe data. The program contains a wide variety of analysis tools, including image maps, correlation plots, simple image math, image filtering, multiple energy image fitting, semi-quantitative elemental analysis, x-ray fluorescence spectrum analysis, principle component analysis, and tomographic reconstructions. To be as widely useful as possible, data formats from many synchrotron sources can be read by the program with more formats available by request. An overview of the most common features will be presented.

  6. First X-ray Fluorescence MicroCT Results from Micrometeorites at SSRL

    SciTech Connect

    Ignatyev, Konstantin; Luening, Katharina; Brennan, Sean; Pianetta, Piero; Huwig, Kathy; Harvey, Ralph; Ishii, Hope; Bradley, John

    2007-01-19

    X-ray fluorescence microCT (computed tomography) is a novel technique that allows non-destructive determination of the 3D distribution of chemical elements inside a sample. This is especially important in samples for which sectioning is undesirable either due to the risk of contamination or the requirement for further analysis by different characterization techniques. Developments made by third generation synchrotron facilities and laboratory X-ray focusing systems have made these kinds of measurements more attractive by significantly reducing scan times and beam size. First results from the x-ray fluorescence microCT experiments performed at SSRL beamline 6-2 are reported here. Beamline 6-2 is a 54 pole wiggler that uses a two mirror optical system for focusing the x-rays onto a virtual source slit which is then reimaged with a set of KB mirrors to a (2 x 4) {mu}m2 beam spot. An energy dispersive fluorescence detector is located in plane at 90 degrees to the incident beam to reduce the scattering contribution. A PIN diode located behind the sample simultaneously measures the x-ray attenuation in the sample. Several porous micrometeorite samples were measured and the reconstructed element density distribution including self-absorption correction is presented. Ultimately, this system will be used to analyze particles from the coma of comet Wild-2 and fresh interstellar dust particles both of which were collected during the NASA Stardust mission.

  7. First X-ray Fluorescence MicroCT Results from Micrometeorites at SSRL

    SciTech Connect

    Ignatyev, K; Huwig, K; Harvey, R; Ishii, H; Bradley, J; Luening, K; Brennan, S; Pianetta, P

    2006-08-23

    X-ray fluorescence microCT (computed tomography) is a novel technique that allows non-destructive determination of the 3D distribution of chemical elements inside a sample. This is especially important in samples for which sectioning is undesirable either due to the risk of contamination or the requirement for further analysis by different characterization techniques. Developments made by third generation synchrotron facilities and laboratory X-ray focusing systems have made these kinds of measurements more attractive by significantly reducing scan times and beam size. First results from the x-ray fluorescence microCT experiments performed at SSRL beamline 6-2 are reported here. Beamline 6-2 is a 54 pole wiggler that uses a two mirror optical system for focusing the x-rays onto a virtual source slit which is then reimaged with a set of KB mirrors to a (2 x 4) {micro}{sup 2} beam spot. An energy dispersive fluorescence detector is located in plane at 90 degrees to the incident beam to reduce the scattering contribution. A PIN diode located behind the sample simultaneously measures the x-ray attenuation in the sample. Several porous micrometeorite samples were measured and the reconstructed element density distribution including self-absorption correction is presented. Ultimately, this system will be used to analyze particles from the coma of comet Wild-2 and fresh interstellar dust particles both of which were collected during the NASA Stardust mission.

  8. First X-ray Fluorescence MicroCT Results from Micrometeorites at SSRL

    NASA Astrophysics Data System (ADS)

    Ignatyev, Konstantin; Huwig, Kathy; Harvey, Ralph; Ishii, Hope; Bradley, John; Luening, Katharina; Brennan, Sean; Pianetta, Piero

    2007-01-01

    X-ray fluorescence microCT (computed tomography) is a novel technique that allows non-destructive determination of the 3D distribution of chemical elements inside a sample. This is especially important in samples for which sectioning is undesirable either due to the risk of contamination or the requirement for further analysis by different characterization techniques. Developments made by third generation synchrotron facilities and laboratory X-ray focusing systems have made these kinds of measurements more attractive by significantly reducing scan times and beam size. First results from the x-ray fluorescence microCT experiments performed at SSRL beamline 6-2 are reported here. Beamline 6-2 is a 54 pole wiggler that uses a two mirror optical system for focusing the x-rays onto a virtual source slit which is then reimaged with a set of KB mirrors to a (2 × 4) μm2 beam spot. An energy dispersive fluorescence detector is located in plane at 90 degrees to the incident beam to reduce the scattering contribution. A PIN diode located behind the sample simultaneously measures the x-ray attenuation in the sample. Several porous micrometeorite samples were measured and the reconstructed element density distribution including self-absorption correction is presented. Ultimately, this system will be used to analyze particles from the coma of comet Wild-2 and fresh interstellar dust particles both of which were collected during the NASA Stardust mission.

  9. TU-A-9A-09: Proton Beam X-Ray Fluorescence CT

    SciTech Connect

    Bazalova, M; Ahmad, M; Fahrig, R; Xing, L

    2014-06-15

    Purpose: To evaluate x-ray fluorescence computed tomography induced with proton beams (pXFCT) for imaging of gold contrast agent. Methods: Proton-induced x-ray fluorescence was studied by means of Monte Carlo (MC) simulations using TOPAS, a MC code based on GEANT4. First, proton-induced K-shell and L-shell fluorescence was studied as a function of proton beam energy and 1) depth in water and 2) size of contrast object. Second, pXFCT images of a 2-cm diameter cylindrical phantom with four 5- mm diameter contrast vials and of a 20-cm diameter phantom with 1-cm diameter vials were simulated. Contrast vials were filled with water and water solutions with 1-5% gold per weight. Proton beam energies were varied from 70-250MeV. pXFCT sinograms were generated based on the net number of gold K-shell or L-shell x-rays determined by interpolations from the neighboring 0.5keV energy bins of spectra collected with an idealized 4π detector. pXFCT images were reconstructed with filtered-back projection, and no attenuation correction was applied. Results: Proton induced x-ray fluorescence spectra showed very low background compared to x-ray induced fluorescence. Proton induced L-shell fluorescence had a higher cross-section compared to K-shell fluorescence. Excitation of L-shell fluorescence was most efficient for low-energy protons, i.e. at the Bragg peak. K-shell fluorescence increased with increasing proton beam energy and object size. The 2% and 5% gold contrast vials were accurately reconstructed in K-shell pXFCT images of both the 2-cm and 20-cm diameter phantoms. Small phantom L-shell pXFCT image required attenuation correction and had a higher sensitivity for 70MeV protons compared to 250MeV protons. With attenuation correction, L-shell pXFCT might be a feasible option for imaging of small size (∼2cm) objects. Imaging doses for all simulations were 5-30cGy. Conclusion: Proton induced x-ray fluorescence CT promises to be an alternative quantitative imaging technique to

  10. Detection limits for actinides in a monochromatic, wavelength-dispersive x-ray fluorescence instrument

    SciTech Connect

    Collins, Michael L; Havrilla, George J

    2009-01-01

    Recent developments in x-ray optics have made it possible to examine the L x-rays of actinides using doubly-curved crystals in a bench-top device. A doubly-curved crystal (DCC) acts as a focusing monochromatic filter for polychromatic x-rays. A Monochromatic, Wavelength-Dispersive X-Ray Fluorescence (MWDXRF) instrument that uses DCCs to measure Cm and Pu in reprocessing plant liquors was proposed in 2007 by the authors at Los Alamos National Laboratory. A prototype design of this MWDXRF instrument was developed in collaboration with X-ray Optical Systems Inc. (XOS), of East Greenbush, New York. In the MWDXRF instrument, x-rays from a Rhodium-anode x-ray tube are passed through a primary DCC to produce a monochromatic beam of 20.2-keV photons. This beam is focused on a specimen that may contain actinides. The 20.2-keV interrogating beam is just above the L3 edge of Californium; each actinide (with Z = 90 to 98) present in the specimen emits characteristic L x-rays as the result of L3-shell vacancies. In the LANL-XOS prototype MWDXRf, these x-rays enter a secondary DCC optic that preferentially passes 14.961-keV photons, corresponding to the L-alpha-1 x-ray peak of Curium. In the present stage of experimentation, Curium-bearing specimens have not been analyzed with the prototype MWDXRF instrument. Surrogate materials for Curium include Rubidium, which has a K-beta-l x-ray at 14.961 keV, and Yttrium, which has a K-alpha-1 x-ray at 14.958 keV. In this paper, the lower limit of detection for Curium in the LANL-XOS prototype MWDXRF instrument is estimated. The basis for this estimate is described, including a description of computational models and benchmarking techniques used. Detection limits for other actinides are considered, as well as future safeguards applications for MWDXRF instrumentation.

  11. A Laboratory-Scale Coaxial Fluorescence and Soft X-ray Microscope for Biological Observation

    NASA Astrophysics Data System (ADS)

    Takaba, K.; Aoki, S.

    2011-09-01

    A laboratory-scale coaxial fluorescence and soft x-ray microscope for biological observation was developed. The characteristic features of a fluorescence microscope were introduced to the conventional soft x-ray microscope, which was developed in our previous study, where the specimens can be set in air. One of the technical difficulties in detecting visible fluorescence is the chromatic aberration. This was overcome by applying a reflective optics, Wolter mirror, to the coaxial optical system. The coaxial optical system offers experimental simplicity and makes it possible to obtain soft x-ray images and fluorescence images of an identical specimen, which can be more informative than applying either imaging modality alone. Therefore, the newly developed optical system offers high-quality structural and morphological details of biological specimens with the ability to localize specific cells and other important sub-cellular targets. Soft x-ray images and fluorescence images of an identical DNA, which were derived from redfish testes and stained with DAPI (4', 6-diamidino-2-phenylindole), were obtained by the newly developed coaxial optical system.

  12. Nanoparticle characterization by means of scanning free grazing emission X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Kayser, Yves; Sá, Jacinto; Szlachetko, Jakub

    2015-05-01

    Nanoparticles are considered for applications in domains as various as medical and pharmaceutical sciences, opto- and microelectronics, catalysis, photovoltaics, spintronics or nano- and biotechnology. The applications realized with nanocrystals depend strongly on the physical dimensions (shape and size) and elemental constitution. We demonstrate here that grazing emission X-ray fluorescence (GEXRF) is an element sensitive technique that presents the potential for a reliable and accurate determination of the morphology of nanoparticles deposited on a flat substrate (ready-to-use devices). Thanks to the scanning-free approach of the used GEXRF setup, the composition, shape and average size of nanoparticles are determined in short time intervals, minimizing the exposure to radiation. The (scanning-free) GEXRF technique allows for in situ investigations of the nanoparticulate systems thanks to the penetration properties of both the probe X-ray beam and the emitted X-ray fluorescence signal.

  13. Use of a Superconducting Tunnel Junction for X-Ray Fluorescence Spectroscopy

    SciTech Connect

    Hiller, L

    2001-03-06

    A superconducting tunnel junction (STJ) in combination with a superconducting absorber of radiation may function as a highly resolving x-ray spectrometer. Electronic excitations, or quasiparticles, are created when a superconductor absorbs an x ray and are detected as an excess tunnel current through the junction. The number of quasiparticles created and the magnitude of the excess current is proportional to the energy of the absorbed x ray. This is similar to existing semiconductor-based spectrometers that measure electron-hole pairs, but with 1000 times more excitations. The energy measurement therefore can be up to 30 times more precise with a superconducting detector than with a semiconductor detector. This work describes the development and testing of an STJ spectrometer design for x-ray fluorescence applications. First, the basic principles of the STJ spectrometer are explained. This is followed by detailed simulations of the variance in the number of quasiparticles produced by absorption of an x ray. This variance is inherent in the detector and establishes an upper limit on the resolving power of the spectrometer. These simulations include effects due to the materials used in the spectrometer and to the multilayer structure of the device. Next, the spectrometer is characterized as functions of operating temperature, incident x-ray energy, and count rate. Many of these tests were performed with the spectrometer attached to a synchrotron radiation port. Finally, example x-ray fluorescence spectra of materials exposed to synchrotron radiation are presented. These materials are of interest to semiconductor processing and structural biology, two fields that will benefit immediately from the improved resolving power of the STJ spectrometer.

  14. Development of an X-ray fluorescence holographic measurement system for protein crystals

    NASA Astrophysics Data System (ADS)

    Sato-Tomita, Ayana; Shibayama, Naoya; Happo, Naohisa; Kimura, Koji; Okabe, Takahiro; Matsushita, Tomohiro; Park, Sam-Yong; Sasaki, Yuji C.; Hayashi, Kouichi

    2016-06-01

    Experimental procedure and setup for obtaining X-ray fluorescence hologram of crystalline metalloprotein samples are described. Human hemoglobin, an α2β2 tetrameric metalloprotein containing the Fe(II) heme active-site in each chain, was chosen for this study because of its wealth of crystallographic data. A cold gas flow system was introduced to reduce X-ray radiation damage of protein crystals that are usually fragile and susceptible to damage. A χ-stage was installed to rotate the sample while avoiding intersection between the X-ray beam and the sample loop or holder, which is needed for supporting fragile protein crystals. Huge hemoglobin crystals (with a maximum size of 8 × 6 × 3 mm3) were prepared and used to keep the footprint of the incident X-ray beam smaller than the sample size during the entire course of the measurement with the incident angle of 0°-70°. Under these experimental and data acquisition conditions, we achieved the first observation of the X-ray fluorescence hologram pattern from the protein crystals with minimal radiation damage, opening up a new and potential method for investigating the stereochemistry of the metal active-sites in biomacromolecules.

  15. Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study.

    PubMed

    Bazalova-Carter, Magdalena; Ahmad, Moiz; Xing, Lei; Fahrig, Rebecca

    2015-10-01

    Thanks to the current advances in nanoscience, molecular biochemistry, and x-ray detector technology, x-ray fluorescence computed tomography (XFCT) has been considered for molecular imaging of probes containing high atomic number elements, such as gold nanoparticles. The commonly used XFCT imaging performed with K-shell x rays appears to have insufficient imaging sensitivity to detect the low gold concentrations observed in small animal studies. Low energy fluorescence L-shell x rays have exhibited higher signal-to-background ratio and appeared as a promising XFCT mode with greatly enhanced sensitivity. The aim of this work was to experimentally demonstrate the feasibility of L-shell XFCT imaging and to assess its achievable sensitivity. We built an experimental L-shell XFCT imaging system consisting of a miniature x-ray tube and two spectrometers, a silicon drift detector (SDD), and a CdTe detector placed at [Formula: see text] with respect to the excitation beam. We imaged a 28-mm-diameter water phantom with 4-mm-diameter Eppendorf tubes containing gold solutions with concentrations of 0.06 to 0.1% Au. While all Au vials were detectable in the SDD L-shell XFCT image, none of the vials were visible in the CdTe L-shell XFCT image. The detectability limit of the presented L-shell XFCT SDD imaging setup was 0.007% Au, a concentration observed in small animal studies.

  16. Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study.

    PubMed

    Bazalova-Carter, Magdalena; Ahmad, Moiz; Xing, Lei; Fahrig, Rebecca

    2015-10-01

    Thanks to the current advances in nanoscience, molecular biochemistry, and x-ray detector technology, x-ray fluorescence computed tomography (XFCT) has been considered for molecular imaging of probes containing high atomic number elements, such as gold nanoparticles. The commonly used XFCT imaging performed with K-shell x rays appears to have insufficient imaging sensitivity to detect the low gold concentrations observed in small animal studies. Low energy fluorescence L-shell x rays have exhibited higher signal-to-background ratio and appeared as a promising XFCT mode with greatly enhanced sensitivity. The aim of this work was to experimentally demonstrate the feasibility of L-shell XFCT imaging and to assess its achievable sensitivity. We built an experimental L-shell XFCT imaging system consisting of a miniature x-ray tube and two spectrometers, a silicon drift detector (SDD), and a CdTe detector placed at [Formula: see text] with respect to the excitation beam. We imaged a 28-mm-diameter water phantom with 4-mm-diameter Eppendorf tubes containing gold solutions with concentrations of 0.06 to 0.1% Au. While all Au vials were detectable in the SDD L-shell XFCT image, none of the vials were visible in the CdTe L-shell XFCT image. The detectability limit of the presented L-shell XFCT SDD imaging setup was 0.007% Au, a concentration observed in small animal studies. PMID:26839910

  17. Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study

    PubMed Central

    Bazalova-Carter, Magdalena; Ahmad, Moiz; Xing, Lei; Fahrig, Rebecca

    2015-01-01

    Abstract. Thanks to the current advances in nanoscience, molecular biochemistry, and x-ray detector technology, x-ray fluorescence computed tomography (XFCT) has been considered for molecular imaging of probes containing high atomic number elements, such as gold nanoparticles. The commonly used XFCT imaging performed with K-shell x rays appears to have insufficient imaging sensitivity to detect the low gold concentrations observed in small animal studies. Low energy fluorescence L-shell x rays have exhibited higher signal-to-background ratio and appeared as a promising XFCT mode with greatly enhanced sensitivity. The aim of this work was to experimentally demonstrate the feasibility of L-shell XFCT imaging and to assess its achievable sensitivity. We built an experimental L-shell XFCT imaging system consisting of a miniature x-ray tube and two spectrometers, a silicon drift detector (SDD), and a CdTe detector placed at ±120  deg with respect to the excitation beam. We imaged a 28-mm-diameter water phantom with 4-mm-diameter Eppendorf tubes containing gold solutions with concentrations of 0.06 to 0.1% Au. While all Au vials were detectable in the SDD L-shell XFCT image, none of the vials were visible in the CdTe L-shell XFCT image. The detectability limit of the presented L-shell XFCT SDD imaging setup was 0.007% Au, a concentration observed in small animal studies. PMID:26839910

  18. Applicability of a cut-off reflector for grazing incidence X-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Tiwari, M. K.; Sawhney, K. J. S.

    2003-11-01

    The applicability of a cut-off reflector, instead of the commonly used multilayer reflector, for grazing incidence X-ray fluorescence (GI-XRF) analysis is demonstrated. Owing to the precise angular adjustment possible in the total reflection X-ray fluorescence (TXRF) spectrometer developed in house, it is possible to adjust the cut-off reflector so as to pass all X-ray energies up to Cu-K α, eliminating Cu-K β and higher X-ray energies emitted from a Cu target X-ray generator. The advantage of this technique is that one gets a higher flux of Cu-K α radiation (>98%) compared to 80-90% from a good quality multilayer optics. Moreover, the same cut-off reflector, used at different grazing angles, serves the purpose for different primary beam energies. The suitability of such an arrangement for GI-XRF analysis for surface characterization has been demonstrated by analyzing a 50 ng aqueous residue of Fe on top of a float glass substrate. The GI-XRF results thus obtained are compared with those obtained using a multilayer monochromator in the primary beam as well as with theoretical calculations.

  19. Preliminary experiment of fluorescent X-ray computed tomography to detect dual agents for biological study.

    PubMed

    Yu, Q; Takeda, T; Yuasa, T; Hasegawa, Y; Wu, J; Thet-Thet-Lwin; Hyodo, K; Dilmanian, F A; Itai, Y; Akatsuka, T

    2001-05-01

    The simultaneous observation of various information, such as blood flow, tissue metabolism and distribution of receptors, is quite important in order to understand the functional state of biomedical objects. The simultaneous detectability of contrast agents by fluorescent X-ray computed tomography (FXCT) with synchrotron radiation is examined in this study. The system consisted of a silicon (111) double-crystal monochromator, an X-ray slit system, a scanning table, a PIN diode, a highly purified germanium detector and an X-ray charge-coupled device (CCD) camera. The monochromatic X-ray beam energy was adjusted to 37.0 keV and collimated into a pencil beam of 1 x 1 mm. The fluorescent spectra of the K alpha lines for iodine and xenon were detected simultaneously. FXCT could image the distribution of both iodine and xenon agents in a phantom clearly and the contrast ratio was significantly better than that of transmission X-ray computed tomography images. PMID:11486409

  20. Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae

    PubMed Central

    Deng, Junjing; Vine, David J.; Chen, Si; Nashed, Youssef S. G.; Jin, Qiaoling; Phillips, Nicholas W.; Peterka, Tom; Ross, Rob; Vogt, Stefan; Jacobsen, Chris J.

    2015-01-01

    Trace metals play important roles in normal and in disease-causing biological functions. X-ray fluorescence microscopy reveals trace elements with no dependence on binding affinities (unlike with visible light fluorophores) and with improved sensitivity relative to electron probes. However, X-ray fluorescence is not very sensitive for showing the light elements that comprise the majority of cellular material. Here we show that X-ray ptychography can be combined with fluorescence to image both cellular structure and trace element distribution in frozen-hydrated cells at cryogenic temperatures, with high structural and chemical fidelity. Ptychographic reconstruction algorithms deliver phase and absorption contrast images at a resolution beyond that of the illuminating lens or beam size. Using 5.2-keV X-rays, we have obtained sub–30-nm resolution structural images and ∼90-nm–resolution fluorescence images of several elements in frozen-hydrated green algae. This combined approach offers a way to study the role of trace elements in their structural context. PMID:25675478

  1. Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae

    SciTech Connect

    Deng, Junjing; Vine, David J.; Chen, Si; Nashed, Youssef S. G.; Jin, Qiaoling; Phillips, Nicholas W.; Peterka, Tom; Ross, Rob; Vogt, Stefan; Jacobsen, Chris J.

    2015-02-24

    Trace metals play important roles in normal and in disease-causing biological functions. X-ray fluorescence microscopy reveals trace elements with no dependence on binding affinities (unlike with visible light fluorophores) and with improved sensitivity relative to electron probes. However, X-ray fluorescence is not very sensitive for showing the light elements that comprise the majority of cellular material. Here we show that X-ray ptychography can be combined with fluorescence to image both cellular structure and trace element distribution in frozen-hydrated cells at cryogenic temperatures, with high structural and chemical fidelity. Ptychographic reconstruction algorithms deliver phase and absorption contrast images at a resolution beyond that of the illuminating lens or beam size. Using 5.2-keV X-rays, we have obtained sub–30-nm resolution structural images and ~90-nm–resolution fluorescence images of several elements in frozen-hydrated green algae. This combined approach offers a way to study the role of trace elements in their structural context.

  2. Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae

    DOE PAGES

    Deng, Junjing; Vine, David J.; Chen, Si; Nashed, Youssef S. G.; Jin, Qiaoling; Phillips, Nicholas W.; Peterka, Tom; Ross, Rob; Vogt, Stefan; Jacobsen, Chris J.

    2015-02-24

    Trace metals play important roles in normal and in disease-causing biological functions. X-ray fluorescence microscopy reveals trace elements with no dependence on binding affinities (unlike with visible light fluorophores) and with improved sensitivity relative to electron probes. However, X-ray fluorescence is not very sensitive for showing the light elements that comprise the majority of cellular material. Here we show that X-ray ptychography can be combined with fluorescence to image both cellular structure and trace element distribution in frozen-hydrated cells at cryogenic temperatures, with high structural and chemical fidelity. Ptychographic reconstruction algorithms deliver phase and absorption contrast images at a resolutionmore » beyond that of the illuminating lens or beam size. Using 5.2-keV X-rays, we have obtained sub–30-nm resolution structural images and ~90-nm–resolution fluorescence images of several elements in frozen-hydrated green algae. This combined approach offers a way to study the role of trace elements in their structural context.« less

  3. Determination of rhenium in molybdenite by X-ray fluorescence. A combined chemical-spectrometric technique

    USGS Publications Warehouse

    Solt, M.W.; Wahlberg, J.S.; Myers, A.T.

    1969-01-01

    Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 ??g of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods. ?? 1969.

  4. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - FIELD PORTABLE X-RAY FLUORESCENCE ANALYZER - HNU SYSTEMS, SEFA-P

    EPA Science Inventory

    In April 1995, the Environmental Protection Agency (EPA) conducted a demonstration of field portable X-ray fluorescence (FPXRF) Analyzers. The primary objectives of this demonstration were (1) to determine how well FPXRF analyzers perform in comparison to a standard reference m...

  5. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - FIELD PORTABLE X-RAY FLUORESCENCE ANALYZER - SCITEC, MAP SPECTRUM ANALYZER

    EPA Science Inventory

    In April 1995, the U.S. Environmental Protection Agency (EPA) sponsored a demonstration of field portable X-ray fluorescence (FPXRF) analyzers. The primary objectives of this demonstration were (1) to determine how well FPXRF analyzers perform in comparison to standard reference...

  6. Energy-Dispersive X-Ray Fluorescence Spectrometry: A Long Overdue Addition to the Chemistry Curriculum

    ERIC Educational Resources Information Center

    Palmer, Peter T.

    2011-01-01

    Portable Energy-Dispersive X-Ray Fluorescence (XRF) analyzers have undergone significant improvements over the past decade. Salient advantages of XRF for elemental analysis include minimal sample preparation, multielement analysis capabilities, detection limits in the low parts per million (ppm) range, and analysis times on the order of 1 min.…

  7. CHARACTERIZATION OF CHROMIUM-CONTAMINATED SOILS USING FIELD-PORTABLE X-RAY FLUORESCENCE

    EPA Science Inventory

    A detailed characterization of the underlying and adjacent soils near a chrome plating shop utilized field-portable X- ray fluorescence (XRF) as a screening tool. XRF permitted real-time acquisition of estimates for total metal content of soils. A trailer-mounted soil coring unit...

  8. Filter-fluorescer measurement of low-voltage simulator x-ray energy spectra

    SciTech Connect

    Baldwin, G.T.; Craven, R.E.

    1986-01-01

    X-ray energy spectra of the Maxwell Laboratories MBS and Physics International Pulserad 737 were measured using an eight-channel filter-fluorescer array. The PHOSCAT computer code was used to calculate channel response functions, and the UFO code to unfold spectrum.

  9. Analysis of tincal ore waste by energy dispersive X-ray fluorescence (EDXRF) Technique

    NASA Astrophysics Data System (ADS)

    Kalfa, Orhan Murat; Üstündağ, Zafer; Özkırım, Ilknur; Kagan Kadıoğlu, Yusuf

    2007-01-01

    Etibank Borax Plant is located in Kırka-Eskişehir, Turkey. The borax waste from this plant was analyzed by means of energy dispersive X-ray fluorescence (EDXRF). The standard addition method was used for the determination of the concentration of Al, Fe, Zn, Sn, and Ba. The results are presented and discussed in this paper.

  10. Rapid screening for zinc deficiency using portable x-ray fluorescence in fingernails

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Elemental composition of fingernails is a useful indicator of micronutrient status and may reflect an individual’s intake over time. Our objective was to determine if portable X-ray fluorescence (XRF) is a viable method to assess zinc content in fingernails in the field. Human fingernail samples ran...

  11. A CHANDRA SURVEY OF FLUORESCENCE Fe LINES IN X-RAY BINARIES AT HIGH RESOLUTION

    SciTech Connect

    Torrejon, J. M.; Schulz, N. S.; Nowak, M. A.; Kallman, T. R.

    2010-06-01

    Fe K line fluorescence is commonly observed in the X-ray spectra of many X-ray binaries (XRBs) and represents a fundamental tool to investigate the material surrounding the X-ray source. In this paper, we present a comprehensive survey of 41 XRBs (10 HMXBs and 31 LMXBs) with Chandra with specific emphasis on the Fe K region and the narrow Fe K{alpha} line, at the highest resolution possible. We find that (1) the Fe K{alpha} line is always centered at {lambda} = 1.9387 {+-} 0.0016 A, compatible with Fe I up to Fe X; we detect no shifts to higher ionization states nor any difference between high mass X-ray binaries (HMXBs) and low mass X-ray binaries (LMXBs). (2) The line is very narrow, with FWHM {<=} 5 mA, normally not resolved by Chandra which means that the reprocessing material is not rotating at high speeds. (3) Fe K{alpha} fluorescence is present in all the HMXBs in the survey. In contrast, such emissions are astonishingly rare ({approx}10%) among LMXBs where only a few out of a large number showed Fe K fluorescence. However, the line and edge properties of these few are very similar to their high mass cousins. (4) The lack of Fe line emission is always accompanied by the lack of any detectable K edge. (5) We obtain the empirical curve of growth of the equivalent width of the Fe K{alpha} line versus the density column of the reprocessing material, i.e., EW{sub K{alpha}} versus N {sub H}, and show that it is consistent with a reprocessing region spherically distributed around the compact object. (6) We show that fluorescence in XRBs follows the X-ray Baldwin effect as previously only found in the X-ray spectra of active galactic nuclei. We interpret this finding as evidence of decreasing neutral Fe abundance with increasing X-ray illumination and use it to explain some spectral states of Cyg X-1 as a possible cause of the lack of narrow Fe line emission in LMXBs. (7) Finally, we study anomalous morphologies such as Compton shoulders and asymmetric line profiles

  12. Modelling of the X-ray fluorescence from Mercury's surface and sodium exosphere

    NASA Astrophysics Data System (ADS)

    Cooper, Rose

    2016-10-01

    We model the fluorescent X-ray signal expected from the Mercury surface. Due to the high solar flux at Mercury, it represents a highly suitable target. Observations of this fluorescence will be performed by the Mercury Imaging X-ray Spectrometer (MIXS) on the upcoming BepiColumbo mission. Accurate modelling is required to plan observation strategies and eventually to quantify the surface composition. In addition, we also investigate the possibility of detecting fluorescence from the exosphere. We are using code modified from that used for the SMART-1 D-CIXS instrument to the Moon. Modifications include detector parameters, solar proximity, likely surface elemental components, and emission from the optically thin exosphere. Modelling of fluorescence from both the surface and exosphere are conducted, with particular emphasis on the sodium component.

  13. Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: A Monte Carlo study

    SciTech Connect

    Manohar, Nivedh; Cho, Sang Hyun

    2014-10-15

    Purpose: To develop an accurate and comprehensive Monte Carlo (MC) model of an experimental benchtop polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) setup and apply this MC model to optimize incident x-ray spectrum for improving production/detection of x-ray fluorescence photons from gold nanoparticles (GNPs). Methods: A detailed MC model, based on an experimental XFCT system, was created using the Monte Carlo N-Particle (MCNP) transport code. The model was validated by comparing MC results including x-ray fluorescence (XRF) and scatter photon spectra with measured data obtained under identical conditions using 105 kVp cone-beam x-rays filtered by either 1 mm of lead (Pb) or 0.9 mm of tin (Sn). After validation, the model was used to investigate the effects of additional filtration of the incident beam with Pb and Sn. Supplementary incident x-ray spectra, representing heavier filtration (Pb: 2 and 3 mm; Sn: 1, 2, and 3 mm) were computationally generated and used with the model to obtain XRF/scatter spectra. Quasimonochromatic incident x-ray spectra (81, 85, 90, 95, and 100 keV with 10 keV full width at half maximum) were also investigated to determine the ideal energy for distinguishing gold XRF signal from the scatter background. Fluorescence signal-to-dose ratio (FSDR) and fluorescence-normalized scan time (FNST) were used as metrics to assess results. Results: Calculated XRF/scatter spectra for 1-mm Pb and 0.9-mm Sn filters matched (r ≥ 0.996) experimental measurements. Calculated spectra representing additional filtration for both filter materials showed that the spectral hardening improved the FSDR at the expense of requiring a much longer FNST. In general, using Sn instead of Pb, at a given filter thickness, allowed an increase of up to 20% in FSDR, more prominent gold XRF peaks, and up to an order of magnitude decrease in FNST. Simulations using quasimonochromatic spectra suggested that increasing source x-ray energy, in the

  14. Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: A Monte Carlo study

    PubMed Central

    Manohar, Nivedh; Jones, Bernard L.; Cho, Sang Hyun

    2014-01-01

    Purpose: To develop an accurate and comprehensive Monte Carlo (MC) model of an experimental benchtop polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) setup and apply this MC model to optimize incident x-ray spectrum for improving production/detection of x-ray fluorescence photons from gold nanoparticles (GNPs). Methods: A detailed MC model, based on an experimental XFCT system, was created using the Monte Carlo N-Particle (MCNP) transport code. The model was validated by comparing MC results including x-ray fluorescence (XRF) and scatter photon spectra with measured data obtained under identical conditions using 105 kVp cone-beam x-rays filtered by either 1 mm of lead (Pb) or 0.9 mm of tin (Sn). After validation, the model was used to investigate the effects of additional filtration of the incident beam with Pb and Sn. Supplementary incident x-ray spectra, representing heavier filtration (Pb: 2 and 3 mm; Sn: 1, 2, and 3 mm) were computationally generated and used with the model to obtain XRF/scatter spectra. Quasimonochromatic incident x-ray spectra (81, 85, 90, 95, and 100 keV with 10 keV full width at half maximum) were also investigated to determine the ideal energy for distinguishing gold XRF signal from the scatter background. Fluorescence signal-to-dose ratio (FSDR) and fluorescence-normalized scan time (FNST) were used as metrics to assess results. Results: Calculated XRF/scatter spectra for 1-mm Pb and 0.9-mm Sn filters matched (r ≥ 0.996) experimental measurements. Calculated spectra representing additional filtration for both filter materials showed that the spectral hardening improved the FSDR at the expense of requiring a much longer FNST. In general, using Sn instead of Pb, at a given filter thickness, allowed an increase of up to 20% in FSDR, more prominent gold XRF peaks, and up to an order of magnitude decrease in FNST. Simulations using quasimonochromatic spectra suggested that increasing source x-ray energy, in the

  15. Full Field X-Ray Fluorescence Imaging Using Micro Pore Optics for Planetary Surface Exploration

    NASA Technical Reports Server (NTRS)

    Sarrazin, P.; Blake, D. F.; Gailhanou, M.; Walter, P.; Schyns, E.; Marchis, F.; Thompson, K.; Bristow, T.

    2016-01-01

    Many planetary surface processes leave evidence as small features in the sub-millimetre scale. Current planetary X-ray fluorescence spectrometers lack the spatial resolution to analyse such small features as they only provide global analyses of areas greater than 100 mm(exp 2). A micro-XRF spectrometer will be deployed on the NASA Mars 2020 rover to analyse spots as small as 120m. When using its line-scanning capacity combined to perpendicular scanning by the rover arm, elemental maps can be generated. We present a new instrument that provides full-field XRF imaging, alleviating the need for precise positioning and scanning mechanisms. The Mapping X-ray Fluorescence Spectrometer - "Map-X" - will allow elemental imaging with approximately 100µm spatial resolution and simultaneously provide elemental chemistry at the scale where many relict physical, chemical and biological features can be imaged in ancient rocks. The arm-mounted Map-X instrument is placed directly on the surface of an object and held in a fixed position during measurements. A 25x25 mm(exp 2) surface area is uniformly illuminated with X-rays or alpha-particles and gamma-rays. A novel Micro Pore Optic focusses a fraction of the emitted X-ray fluorescence onto a CCD operated at a few frames per second. On board processing allows measuring the energy and coordinates of each X-ray photon collected. Large sets of frames are reduced into 2d histograms used to compute higher level data products such as elemental maps and XRF spectra from selected regions of interest. XRF spectra are processed on the ground to further determine quantitative elemental compositions. The instrument development will be presented with an emphasis on the characterization and modelling of the X-ray focussing Micro Pore Optic. An outlook on possible alternative XRF imaging applications will be discussed.

  16. High resolution x-ray fluorescence spectroscopy - a new technique for site- and spin-selectivity

    SciTech Connect

    Wang, Xin

    1996-12-01

    X-ray spectroscopy has long been used to elucidate electronic and structural information of molecules. One of the weaknesses of x-ray absorption is its sensitivity to all of the atoms of a particular element in a sample. Through out this thesis, a new technique for enhancing the site- and spin-selectivity of the x-ray absorption has been developed. By high resolution fluorescence detection, the chemical sensitivity of K emission spectra can be used to identify oxidation and spin states; it can also be used to facilitate site-selective X-ray Absorption Near Edge Structure (XANES) and site-selective Extended X-ray Absorption Fine Structure (EXAFS). The spin polarization in K fluorescence could be used to generate spin selective XANES or spin-polarized EXAFS, which provides a new measure of the spin density, or the nature of magnetic neighboring atoms. Finally, dramatic line-sharpening effects by the combination of absorption and emission processes allow observation of structure that is normally unobservable. All these unique characters can enormously simplify a complex x-ray spectrum. Applications of this novel technique have generated information from various transition-metal model compounds to metalloproteins. The absorption and emission spectra by high resolution fluorescence detection are interdependent. The ligand field multiplet model has been used for the analysis of K{alpha} and K{beta} emission spectra. First demonstration on different chemical states of Fe compounds has shown the applicability of site selectivity and spin polarization. Different interatomic distances of the same element in different chemical forms have been detected using site-selective EXAFS.

  17. A High-Speed Detector System for X-ray Fluorescence Microprobes.

    SciTech Connect

    Siddons,P.D.; Dragone, A.; De Geronimo, g.; Kuczewski, A.; Kuczewski, J.; O

    2006-10-29

    We have developed a high-speed system for collecting x-ray fluorescence microprobe data, based on ASICs developed at BNL and high-speed processors developed by CSIRO. The system can collect fluorescence data in a continuous raster scan mode, and present elemental images in real time using Ryan's Dynamic Analysis algorithm. We will present results from a 32-element prototype array illustrating the concept. The final instrument will have 384 elements arranged in a square array around a central hole.

  18. Spatially resolved density and ionization measurements of shocked foams using x-ray fluorescence

    NASA Astrophysics Data System (ADS)

    MacDonald, M. J.; Keiter, P. A.; Montgomery, D. S.; Scott, H. A.; Biener, M. M.; Fein, J. R.; Fournier, K. B.; Gamboa, E. J.; Kemp, G. E.; Klein, S. R.; Kuranz, C. C.; LeFevre, H. J.; Manuel, M. J.-E.; Wan, W. C.; Drake, R. P.

    2016-09-01

    We present experiments at the Trident laser facility demonstrating the use of x-ray fluorescence (XRF) to simultaneously measure density, ionization state populations, and electron temperature in shocked foams. An imaging x-ray spectrometer obtained spatially resolved measurements of Ti K-α emission. Density profiles were measured from K-α intensity. Ti ionization state distributions and electron temperatures were inferred by fitting K-α spectra to spectra from CRETIN simulations. This work shows that XRF provides a powerful tool to complement other diagnostics to make equation of state measurements of shocked materials containing a suitable tracer element.

  19. Surface extended x-ray absorption fine structure of low-Z absorbates using fluorescence detection

    SciTech Connect

    Stoehr, J.; Kollin, E.B.; Fischer, D.A.; Hastings, J.B.; Zaera, F.; Sette, F.

    1985-05-01

    Comparison of x-ray fluorescence yield (FY) and electron yield surface extended x-ray absorption fine structure spectra above the S K-edge for c(2 x 2) S on Ni(100) reveals an order of magnitude higher sensitivity of the FY technique. Using FY detection, thiophene (C/sub 4/H/sub 4/S) chemisorption on Ni(100) is studied with S coverages down to 0.08 monolayer. The molecule dissociates at temperatures as low as 100K by interaction with fourfold hollow Ni sites. Blocking of these sites by oxygen leaves the molecule intact.

  20. X-ray fluorescence microtomography of SiC shells

    SciTech Connect

    Ice, G.E.; Chung, J.S.; Nagedolfeizi, M.

    1997-04-01

    TRISCO coated fuel particles contain a small kernel of nuclear fuel encapsulated by alternating layers of C and SiC. The TRISCO coated fuel particle is used in an advanced fuel designed for passive containment of the radioactive isotopes. The SiC layer provides the primary barrier for radioactive elements in the kernel. The effectiveness of this barrier layer under adverse conditions is critical to containment. The authors have begun the study of SiC shells from TRISCO fuel. They are using the fluorescent microprobe beamline 10.3.1. The shells under evaluation include some which have been cycled through a simulated core melt-down. The C buffer layers and nuclear kernels of the coated fuel have been removed by laser drilling through the SiC and then exposing the particle to acid. Elements of interest include Ru, Sb, Cs, Ce and Eu. The radial distribution of these elements in the SiC shells can be attributed to diffusion of elements in the kernel during the melt-down. Other elements in the shells originate during the fabrication of the TRISCO particles.

  1. Molar concentration from sequential 2-D water-window X-ray ptychography and X-ray fluorescence in hydrated cells

    NASA Astrophysics Data System (ADS)

    Jones, M. W. M.; Elgass, K. D.; Junker, M. D.; de Jonge, M. D.; van Riessen, G. A.

    2016-04-01

    Recent developments in biological X-ray microscopy have allowed structural information and elemental distribution to be simultaneously obtained by combining X-ray ptychography and X-ray fluorescence microscopy. Experimentally, these methods can be performed simultaneously; however, the optimal conditions for each measurement may not be compatible. Here, we combine two distinct measurements of ultrastructure and elemental distribution, with each measurement performed under optimised conditions. By combining optimised ptychography and fluorescence information we are able to determine molar concentrations from two-dimensional images, allowing an investigation into the interactions between the environment sensing filopodia in fibroblasts and extracellular calcium. Furthermore, the biological ptychography results we present illustrate a point of maturity where the technique can be applied to solve significant problems in structural biology.

  2. Optimizing Monocapillary Optics for Synchrotron X-ray Diffraction, Fluorescence Imaging, and Spectroscopy Applications

    NASA Astrophysics Data System (ADS)

    Bilderback, Donald H.; Kazimirov, Alexander; Gillilan, Richard; Cornaby, Sterling; Woll, Arthur; Zha, Chang-Sheng; Huang, Rong

    2007-01-01

    A number of synchrotron x-ray applications such as powder diffraction in diamond anvil cells, microbeam protein crystallography, x-ray fluorescence imaging, etc. can benefit from using hollow glass monocapillary optics to improve the flux per square micron on a sample. We currently draw glass tubing into the desired elliptical shape so that only one-bounce under total reflection conditions is needed to bring the x-ray beam to a focus at a 25 to 50 mm distance beyond the capillary tip. For modest focal spot sizes of 10 to 20 microns, we can increase the intensity per square micron by factors of 10 to 1000. We show some of the results obtained at CHESS and Hasylab with capillaries focusing 5 to 40 keV radiation, their properties, and how even better the experimental results could be if more ideal capillaries were fabricated in the future.

  3. Optimizing Monocapillary Optics for Synchrotron X-ray Diffraction, Fluorescence Imaging, and Spectroscopy Applications

    SciTech Connect

    Bilderback, Donald H.; Kazimirov, Alexander; Gillilan, Richard; Cornaby, Sterling; Woll, Arthur; Zha, Chang-Sheng; Huang Rong

    2007-01-19

    A number of synchrotron x-ray applications such as powder diffraction in diamond anvil cells, microbeam protein crystallography, x-ray fluorescence imaging, etc. can benefit from using hollow glass monocapillary optics to improve the flux per square micron on a sample. We currently draw glass tubing into the desired elliptical shape so that only one-bounce under total reflection conditions is needed to bring the x-ray beam to a focus at a 25 to 50 mm distance beyond the capillary tip. For modest focal spot sizes of 10 to 20 microns, we can increase the intensity per square micron by factors of 10 to 1000. We show some of the results obtained at CHESS and Hasylab with capillaries focusing 5 to 40 keV radiation, their properties, and how even better the experimental results could be if more ideal capillaries were fabricated in the future.

  4. Application of X-ray fluorescence analytical techniques in phytoremediation and plant biology studies

    NASA Astrophysics Data System (ADS)

    Nečemer, Marijan; Kump, Peter; Ščančar, Janez; Jaćimović, Radojko; Simčič, Jurij; Pelicon, Primož; Budnar, Miloš; Jeran, Zvonka; Pongrac, Paula; Regvar, Marjana; Vogel-Mikuš, Katarina

    2008-11-01

    Phytoremediation is an emerging technology that employs the use of higher plants for the clean-up of contaminated environments. Progress in the field is however handicapped by limited knowledge of the biological processes involved in plant metal uptake, translocation, tolerance and plant-microbe-soil interactions; therefore a better understanding of the basic biological mechanisms involved in plant/microbe/soil/contaminant interactions would allow further optimization of phytoremediation technologies. In view of the needs of global environmental protection, it is important that in phytoremediation and plant biology studies the analytical procedures for elemental determination in plant tissues and soil should be fast and cheap, with simple sample preparation, and of adequate accuracy and reproducibility. The aim of this study was therefore to present the main characteristics, sample preparation protocols and applications of X-ray fluorescence-based analytical techniques (energy dispersive X-ray fluorescence spectrometry—EDXRF, total reflection X-ray fluorescence spectrometry—TXRF and micro-proton induced X-ray emission—micro-PIXE). Element concentrations in plant leaves from metal polluted and non-polluted sites, as well as standard reference materials, were analyzed by the mentioned techniques, and additionally by instrumental neutron activation analysis (INAA) and atomic absorption spectrometry (AAS). The results were compared and critically evaluated in order to assess the performance and capability of X-ray fluorescence-based techniques in phytoremediation and plant biology studies. It is the EDXRF, which is recommended as suitable to be used in the analyses of a large number of samples, because it is multi-elemental, requires only simple preparation of sample material, and it is analytically comparable to the most frequently used instrumental chemical techniques. The TXRF is compatible to FAAS in sample preparation, but relative to AAS it is fast

  5. X-ray fluorescence analysis of low concentrations metals in geological samples and technological products

    NASA Astrophysics Data System (ADS)

    Lagoida, I. A.; Trushin, A. V.

    2016-02-01

    For the past several years many nuclear physics methods of quantitative elemental analysis have been designed. Many of these methods have applied in different devices which have become useful and effective instrument in many industrial laboratories. Methods of a matter structure analysis are based on the intensity detection of the X-ray radiation from the nuclei of elements which are excited by external X-ray source. The production of characteristic X-rays involves transitions of the orbital electrons of atoms in the target material between allowed orbits, or energy states, associated with ionization of the inner atomic shells. One of these methods is X-ray fluorescence analysis, which is widespread in metallurgical and processing industries and is used to identify and measure the concentration of the elements in ores and minerals on a conveyor belt. Samples of copper ore with known concentrations of elements, were taken from the Ural deposit. To excite the characteristic X-rays radionuclide sources 109Cd, with half-life 461.4 days were used. After finding the calibration coefficients, control measurements of samples and averaging of overall samples were made. The measurement error did not exceed 3%.

  6. A flexible setup for angle-resolved X-ray fluorescence spectrometry with laboratory sources.

    PubMed

    Spanier, M; Herzog, C; Grötzsch, D; Kramer, F; Mantouvalou, I; Lubeck, J; Weser, J; Streeck, C; Malzer, W; Beckhoff, B; Kanngießer, B

    2016-03-01

    X-ray fluorescence (XRF) analysis is one of the standard tools for the analysis of stratified materials and is widely applied for the investigation of electronics and coatings. The composition and thickness of the layers can be determined quantitatively and non-destructively. Recent work showed that these capabilities can be extended towards retrieving stratigraphic information like concentration depth profiles using angle-resolved XRF (ARXRF). This paper introduces an experimental sample chamber which was developed as a multi-purpose tool enabling different measurement geometries suited for transmission measurements, conventional XRF, ARXRF, etc. The chamber was specifically designed for attaching all kinds of laboratory X-ray sources for the soft and hard X-ray ranges as well as various detection systems. In detail, a setup for ARXRF using an X-ray tube with a polycapillary X-ray lens as source is presented. For such a type of setup, both the spectral and lateral characterizations of the radiation field are crucial for quantitative ARXRF measurements. The characterization is validated with the help of a stratified validation sample. PMID:27036820

  7. Sub-micron Hard X-ray Fluorescence Imaging of Synthetic Elements

    PubMed Central

    Jensen, Mark P.; Aryal, Baikuntha P.; Gorman-Lewis, Drew; Paunesku, Tatjana; Lai, Barry; Vogt, Stefan; Woloschak, Gayle E.

    2013-01-01

    Synchrotron-based X-ray fluorescence microscopy (SXFM) using hard X-rays focused into sub-micron spots is a powerful technique for elemental quantification and mapping, as well as microspectroscopic measurement such as μ-XANES (X-ray absorption near edge structure). We have used SXFM to image and simultaneously quantify the transuranic element plutonium at the L3 or L2 edge as well as lighter biologically essential elements in individual rat pheochromocytoma (PC12) cells after exposure to the long-lived plutonium isotope 242Pu. Elemental maps reveal that plutonium localizes principally in the cytoplasm of the cells and avoids the cell nucleus, which is marked by the highest concentrations of phosphorus and zinc, under the conditions of our experiments. The minimum detection limit under typical acquisition conditions for an average 202 μm2 cell is 1.4 fg Pu/cell or 2.9 × 10−20 moles Pu/μm2, which is similar to the detection limit of K-edge SXFM of transition metals at 10 keV. Copper electron microscopy grids were used to avoid interference from gold X-ray emissions, but traces of strontium present in naturally occurring calcium can still interfere with plutonium detection using its Lα X-ray emission. PMID:22444530

  8. Soft-x-ray fluorescence study of buried silicides in antiferromagnetically coupled Fe/Si multilayers

    SciTech Connect

    Carlisle, J.A.; Chaiken, A.; Michel, R.P.

    1997-04-01

    Multilayer films made by alternate deposition of two materials play an important role in electronic and optical devices such as quantum-well lasers and x-ray mirrors. In addition, novel phenomena like giant magnetoresistance and dimensional crossover in superconductors have emerged from studies of multilayers. While sophisticated x-ray techniques are widely used to study the morphology of multilayer films, progress in studying the electronic structure has been slower. The short mean-free path of low-energy electrons severely limits the usefulness of photoemission and related electron free path of low-energy electrons severely limit spectroscopies for multilayer studies. Soft x-ray fluorescence (SXF) is a bulk-sensitive photon-in, photon-out method to study valence band electronic states. Near-edge x-ray absorption fine-structure spectroscopy (NEXAFS) measured with partial photon yield can give complementary bulk-sensitive information about unoccupied states. Both these methods are element-specific since the incident x-ray photons excite electrons from core levels. By combining NEXAFS and SXF measurements on buried layers in multilayers and comparing these spectra to data on appropriate reference compounds, it is possible to obtain a detailed picture of the electronic structure. Results are presented for a study of a Fe/Si multilayer system.

  9. Evaluation of different synchrotron beamline configurations for X-ray fluorescence analysis of environmental samples.

    PubMed

    Barberie, Sean R; Iceman, Christopher R; Cahill, Catherine F; Cahill, Thomas M

    2014-08-19

    Synchrotron radiation X-ray fluorescence (SR-XRF) is a powerful elemental analysis tool, yet synchrotrons are large, multiuser facilities that are generally not amenable to modification. However, the X-ray beamlines from synchrotrons can be modified by simply including X-ray filters or removing monochromators to improve the SR-XRF analysis. In this study, we evaluated four easily applied beamline configurations for the analysis of three representative environmental samples, namely a thin aerosol sample, an intermediate thickness biological sample, and a thick rare earth mineral specimen. The results showed that the "white beam" configuration, which was simply the full, polychromatic output of the synchrotron, was the optimal configuration for the analysis of thin samples with little mass. The "filtered white beam" configuration removed the lower energy X-rays from the excitation beam so it gave better sensitivity for elements emitting more energetic X-rays. The "filtered white beam-filtered detector" configuration sacrifices the lower energy part of the spectrum (<15 keV) for improved sensitivity in the higher end (∼26 to 48 keV range). The use of a monochromatic beam, which tends to be the standard mode of operation for most SR-XRF analyses reported in the literature, gave the least sensitive analysis.

  10. A flexible setup for angle-resolved X-ray fluorescence spectrometry with laboratory sources

    NASA Astrophysics Data System (ADS)

    Spanier, M.; Herzog, C.; Grötzsch, D.; Kramer, F.; Mantouvalou, I.; Lubeck, J.; Weser, J.; Streeck, C.; Malzer, W.; Beckhoff, B.; Kanngießer, B.

    2016-03-01

    X-ray fluorescence (XRF) analysis is one of the standard tools for the analysis of stratified materials and is widely applied for the investigation of electronics and coatings. The composition and thickness of the layers can be determined quantitatively and non-destructively. Recent work showed that these capabilities can be extended towards retrieving stratigraphic information like concentration depth profiles using angle-resolved XRF (ARXRF). This paper introduces an experimental sample chamber which was developed as a multi-purpose tool enabling different measurement geometries suited for transmission measurements, conventional XRF, ARXRF, etc. The chamber was specifically designed for attaching all kinds of laboratory X-ray sources for the soft and hard X-ray ranges as well as various detection systems. In detail, a setup for ARXRF using an X-ray tube with a polycapillary X-ray lens as source is presented. For such a type of setup, both the spectral and lateral characterizations of the radiation field are crucial for quantitative ARXRF measurements. The characterization is validated with the help of a stratified validation sample.

  11. [Application of Three Dimensional Confocal Micro X-Ray Fluorescence Technology Based on Polycapillary X-Ray Lens in Analysis of Rock and Mineral Samples].

    PubMed

    Li, Fang-zuo; Liu, Zhi-guo; Sun, Tian-xi; Yi, Long-tao; Zhao, Wei-gang; He, Jia-lin; Peng, Song; Wang, Li-li; Zhao, Guang-cui; Ding, Xun-liang

    2015-09-01

    Confocal three dimensional (3D) micro X-ray fluorescence (XRF) spectrometer based on a polycapillary focusing X-ray lens (PFXRL) in the excitation channel and a polycapillary parallel X-ray lens (PPXRL) in the detection channel was developed. The PFXRL and PPXRL were placed in a confocal configuration. This was helpful in improving the signal-to-noise ratio of the XRF spectra, and accordingly lowered the detection limitation of the XRF technology. The confocal configuration ensured that only the XRF signal from the confocal micro-volume overlapped by the output focal spot of the PFXRL and the input focal spot of the PPXRL could be detected by the detector. Therefore, the point-to-point information of XRF for samples could be obtained non-destructively by moving the sample located at the confocal position. The magnitude of the gain in power density of the PFXRL was 10(3). This let the low power conventional X-ray source be used in this confocal XRF, and, accordingly, decreased the requirement of high power X-ray source for the confocal XRF based on polycapillary X-ray optics. In this paper, we used the confocal 3D micro X-ray fluorescence spectrometer to non-destructively analyzed mineral samples and to carry out a 3D point-to-point elemental mapping scanning, which demonstrated the capabilities of confocal 3D micro XRF technology for non-destructive analysis elements composition and distribution for mineral samples. For one mineral sample, the experimental results showed that the area with high density of element of iron had high density of copper. To some extent, this reflected the growth mechanisms of the mineral sample. The confocal 3D micro XRF technology has potential applications in such fields like the analysis identification of ore, jade, lithoid utensils, "gamble stone" and lithoid flooring.

  12. ENVIRONMENTAL TECHNOLOGY VERFICATION REPORT - FIELD PORTABLE X-RAY FLUORESCENCE ANALYZER - TN SPECTRACE, TN 9000 AND TN PB FIELD PORTABLE X-RAY FLOURESCENCE ANALYZERS

    EPA Science Inventory

    In April 1995, the U.S. Environmental Protection Agency (EPA) sponsored a demonstration of field portable X-ray fluorescence (FPXRF) analyzers. The primary objectives of this demonstration were to evaluate these analyzers for: (1) their analytical performance relative to standar...

  13. Characterization of energy response for photon-counting detectors using x-ray fluorescence

    PubMed Central

    Ding, Huanjun; Cho, Hyo-Min; Barber, William C.; Iwanczyk, Jan S.; Molloi, Sabee

    2014-01-01

    Purpose: To investigate the feasibility of characterizing a Si strip photon-counting detector using x-ray fluorescence. Methods: X-ray fluorescence was generated by using a pencil beam from a tungsten anode x-ray tube with 2 mm Al filtration. Spectra were acquired at 90° from the primary beam direction with an energy-resolved photon-counting detector based on an edge illuminated Si strip detector. The distances from the source to target and the target to detector were approximately 19 and 11 cm, respectively. Four different materials, containing silver (Ag), iodine (I), barium (Ba), and gadolinium (Gd), were placed in small plastic containers with a diameter of approximately 0.7 cm for x-ray fluorescence measurements. Linear regression analysis was performed to derive the gain and offset values for the correlation between the measured fluorescence peak center and the known fluorescence energies. The energy resolutions and charge-sharing fractions were also obtained from analytical fittings of the recorded fluorescence spectra. An analytical model, which employed four parameters that can be determined from the fluorescence calibration, was used to estimate the detector response function. Results: Strong fluorescence signals of all four target materials were recorded with the investigated geometry for the Si strip detector. The average gain and offset of all pixels for detector energy calibration were determined to be 6.95 mV/keV and −66.33 mV, respectively. The detector’s energy resolution remained at approximately 2.7 keV for low energies, and increased slightly at 45 keV. The average charge-sharing fraction was estimated to be 36% within the investigated energy range of 20–45 keV. The simulated detector output based on the proposed response function agreed well with the experimental measurement. Conclusions: The performance of a spectral imaging system using energy-resolved photon-counting detectors is very dependent on the energy calibration of the

  14. Characterization of energy response for photon-counting detectors using x-ray fluorescence

    SciTech Connect

    Ding, Huanjun; Cho, Hyo-Min; Molloi, Sabee; Barber, William C.; Iwanczyk, Jan S.

    2014-12-15

    Purpose: To investigate the feasibility of characterizing a Si strip photon-counting detector using x-ray fluorescence. Methods: X-ray fluorescence was generated by using a pencil beam from a tungsten anode x-ray tube with 2 mm Al filtration. Spectra were acquired at 90° from the primary beam direction with an energy-resolved photon-counting detector based on an edge illuminated Si strip detector. The distances from the source to target and the target to detector were approximately 19 and 11 cm, respectively. Four different materials, containing silver (Ag), iodine (I), barium (Ba), and gadolinium (Gd), were placed in small plastic containers with a diameter of approximately 0.7 cm for x-ray fluorescence measurements. Linear regression analysis was performed to derive the gain and offset values for the correlation between the measured fluorescence peak center and the known fluorescence energies. The energy resolutions and charge-sharing fractions were also obtained from analytical fittings of the recorded fluorescence spectra. An analytical model, which employed four parameters that can be determined from the fluorescence calibration, was used to estimate the detector response function. Results: Strong fluorescence signals of all four target materials were recorded with the investigated geometry for the Si strip detector. The average gain and offset of all pixels for detector energy calibration were determined to be 6.95 mV/keV and −66.33 mV, respectively. The detector’s energy resolution remained at approximately 2.7 keV for low energies, and increased slightly at 45 keV. The average charge-sharing fraction was estimated to be 36% within the investigated energy range of 20–45 keV. The simulated detector output based on the proposed response function agreed well with the experimental measurement. Conclusions: The performance of a spectral imaging system using energy-resolved photon-counting detectors is very dependent on the energy calibration of the

  15. Potential applications of polycapillary optics to polarized beam X-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Hussain, Abrar M.

    The Polarized beam X-ray fluorescence (XRF) technique has potential applications in elemental analysis in materials analysis and in-vivo. In this work, first micro X-ray fluorescence (MXRF) measurements were done using a focusing lens. Polarization can be used to reduce the background, to give a better minimum detection limit. Polarizing the beam, using scattering has a disadvantage of low intensity and white beam background. Beam polarized by diffraction after collimating lens gives better results. A suitable crystal satisfying Bragg's condition gives a monochromatic as well as polarized beam with good intensity. Using a polycapillary lens increases the intensity of the X-ray beam using a laboratory based X-ray source with compact experimental set-up. Experimental results confirm the decrease in background in the polarization direction and the improvement in minimum detectable limit using the polarized beam. Verification of calculated results from measurements allows optimization of a laboratory based system with respect to source, lens and geometry parameters. MDL as low as ppm for bulk samples are predicted.

  16. Optimizing detector geometry for trace element mapping by X-ray fluorescence

    SciTech Connect

    Sun, Yue; Gleber, Sophie -Charlotte; Jacobsen, Chris; Kirz, Janos; Vogt, Stefan

    2015-01-01

    We report that trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. In conclusion, we conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.

  17. Optimizing detector geometry for trace element mapping by X-ray fluorescence

    DOE PAGES

    Sun, Yue; Gleber, Sophie -Charlotte; Jacobsen, Chris; Kirz, Janos; Vogt, Stefan

    2015-01-01

    We report that trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral responsemore » of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. In conclusion, we conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.« less

  18. Optimizing detector geometry for trace element mapping by X-ray fluorescence

    PubMed Central

    Sun, Yue; Gleber, Sophie-Charlotte; Jacobsen, Chris; Kirz, Janos; Vogt, Stefan

    2016-01-01

    Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples. PMID:25600825

  19. Energetic electron processes fluorescence effects for structured nanoparticles X-ray analysis and nuclear medicine applications

    NASA Astrophysics Data System (ADS)

    Taborda, A.; Desbrée, A.; Carvalho, A.; Chaves, P. C.; Reis, M. A.

    2016-08-01

    Superparamagnetic iron oxide (SPIO) nanoparticles are widely used as contrast agents for nuclear magnetic resonance imaging (MRI), and can be modified for improved imaging or to become tissue-specific or even protein-specific. The knowledge of their detailed elemental composition characterisation and potential use in nuclear medicine applications, is, therefore, an important issue. X-ray fluorescence techniques such as particle induced X-ray emission (PIXE) or X-ray fluorescence spectrometry (XRF), can be used for elemental characterisation even in problematic situations where very little sample volume is available. Still, the fluorescence coefficient of Fe is such that, during the decay of the inner-shell ionised atomic structure, keV Auger electrons are produced in excess to X-rays. Since cross-sections for ionisation induced by keV electrons, for low atomic number atoms, are of the order of 103 barn, care should be taken to account for possible fluorescence effects caused by Auger electrons, which may lead to the wrong quantification of elements having atomic number lower than the atomic number of Fe. Furthermore, the same electron processes will occur in iron oxide nanoparticles containing 57Co, which may be used for nuclear medicine therapy purposes. In the present work, simple approximation algorithms are proposed for the quantitative description of radiative and non-radiative processes associated with Auger electrons cascades. The effects on analytical processes and nuclear medicine applications are quantified for the case of iron oxide nanoparticles, by calculating both electron fluorescence emissions and energy deposition on cell tissues where the nanoparticles may be embedded.

  20. Bent Laue X-ray Fluorescence Imaging of Manganese in Biological Tissues--Preliminary Results

    SciTech Connect

    Zhu Ying; Zhang Honglin; Bewer, Brian; Nichol, Helen; Chapman, Dean; Thomlinson, Bill

    2010-06-23

    Manganese (Mn) is not abundant in human brain tissue, but it is recognized as a neurotoxin. The symptoms of manganese intoxication are similar to Parkinson's disease (PD), but the link between environmental, occupational or dietary Mn exposure and PD in humans is not well established. X-ray Absorption Spectroscopy (XAS) and in particular X-ray fluorescence can provide precise information on the distribution, concentration and chemical form of metals. However the scattered radiation and fluorescence from the adjacent abundant element, iron (Fe), may interfere with and limit the ability to detect ultra-dilute Mn. A bent Laue analyzer based Mn fluorescence detection system has been designed and fabricated to improve elemental specificity in XAS imaging. This bent Laue analyzer of logarithmic spiral shape placed upstream of an energy discriminating detector should improve the energy resolution from hundreds of eV to several eV. The bent Laue detection system was validated by imaging Mn fluorescence from Mn foils, gelatin calibration samples and adult Drosophila at the Hard X-ray MicroAnalysis (HXMA) beamline at the Canadian Light Source (CLS). Optimization of the design parameters, fabrication procedures and preliminary experimental results are presented along with future plans.

  1. Computed tomography and X-ray fluorescence CT of biological samples

    NASA Astrophysics Data System (ADS)

    Pereira, G. R.; Anjos, M. J.; Rocha, H. S.; Faria, P.; Pérez, C. A.; Lopes, R. T.

    2007-10-01

    Transmission microtomography ( μCT) and X-ray fluorescence microtomography (XRF μCT) are complementary and noninvasive techniques used for sample characterization. μCT provide information on the attenuation coefficients, while XRF μCT can provide the distribution of all elements in a sample. XRF μCT is a noninvasive technique, based on the detection of X-ray fluorescence emitted by the elements in the sample, and it is used to complement other techniques for sample characterization. The experiments were performed at the X-Ray Fluorescence (XRF) beamline of the Brazilian Synchrotron Light Laboratory (LNLS), Campinas, Brazil. A monochromatic beam of 9.8 keV was used for excitation of the elements within samples and the fluorescence photons were detected by an HPGe detector. The incident beam was monitored by an ionization chamber and a fast scintillator detector was used to detect the transmitted radiation. In this work, several intestine and breast tissue samples were investigated in order to verify the concentration of some elements correlated with the characteristics and pathology of each tissue observed by transmission μCT. All XRF μCT were reconstructed using a filtered back-projection algorithm. In those samples the elements Zn, Cu, and Fe were observed.

  2. Bent Laue X-ray Fluorescence Imaging of Manganese in Biological Tissues—Preliminary Results

    NASA Astrophysics Data System (ADS)

    Zhu, Ying; Bewer, Brian; Zhang, Honglin; Nichol, Helen; Thomlinson, Bill; Chapman, Dean

    2010-06-01

    Manganese (Mn) is not abundant in human brain tissue, but it is recognized as a neurotoxin. The symptoms of manganese intoxication are similar to Parkinson's disease (PD), but the link between environmental, occupational or dietary Mn exposure and PD in humans is not well established. X-ray Absorption Spectroscopy (XAS) and in particular X-ray fluorescence can provide precise information on the distribution, concentration and chemical form of metals. However the scattered radiation and fluorescence from the adjacent abundant element, iron (Fe), may interfere with and limit the ability to detect ultra-dilute Mn. A bent Laue analyzer based Mn fluorescence detection system has been designed and fabricated to improve elemental specificity in XAS imaging. This bent Laue analyzer of logarithmic spiral shape placed upstream of an energy discriminating detector should improve the energy resolution from hundreds of eV to several eV. The bent Laue detection system was validated by imaging Mn fluorescence from Mn foils, gelatin calibration samples and adult Drosophila at the Hard X-ray MicroAnalysis (HXMA) beamline at the Canadian Light Source (CLS). Optimization of the design parameters, fabrication procedures and preliminary experimental results are presented along with future plans.

  3. Characterization of phosphorus in organisms at sub-micron resolution using X-ray fluorescence spectromicroscopy.

    SciTech Connect

    Diaz, J.; Ingall, E; Vogt, S; Paterson, D; DeJonge, M; Rao, C; Brandes, J

    2009-01-01

    X-ray spectromicroscopy (combined X-ray spectroscopy and microscopy) is uniquely capable of determining sub-micron scale elemental content and chemical speciation in minimally-prepared particulate samples. The high spatial resolutions achievable with this technique have enabled the close examination of important microscale processes relevant to the cycling of biogeochemically important elements. Here, we demonstrate the value of X-ray microscopy to environmental and biological research by examining the phosphorus and metal chemistry of complete individual cells from the algal genera Chlamydomonas sp. and Chlorella sp. X-ray analysis revealed that both genera store substantial intracellular phosphorus as distinct, heterogeneously distributed granules whose X-ray fluorescence spectra are consistent with that of polyphosphate. Polyphosphate inclusions ranged in size from 0.3-1.4 {micro}m in diameter and exhibited a nonspecies-specific average phosphorus concentration of 6.87 {+-} 1.86 {micro}g cm{sup -2}, which was significantly higher than the average concentration of phosphorus measured in the total cell, at 3.14 {+-} 0.98 {micro}g cm{sup -2} (95% confidence). Polyphosphate was consistently associated with calcium and iron, exhibiting average P:cation molar ratios of 8.31 {+-} 2.00 and 108 {+-} 34, respectively (95% confidence). In some cells, polyphosphate was also associated with potassium, zinc, manganese, and titanium. Based on our results, X-ray spectromicroscopy can provide high-resolution elemental data on minimally prepared, unsectioned cells that are unattainable through alternative microscopic methods and conventional bulk chemical techniques currently available in many fields of marine chemistry.

  4. New developments of X-ray fluorescence imaging techniques in laboratory

    NASA Astrophysics Data System (ADS)

    Tsuji, Kouichi; Matsuno, Tsuyoshi; Takimoto, Yuki; Yamanashi, Masaki; Kometani, Noritsugu; Sasaki, Yuji C.; Hasegawa, Takeshi; Kato, Shuichi; Yamada, Takashi; Shoji, Takashi; Kawahara, Naoki

    2015-11-01

    X-ray fluorescence (XRF) analysis is a well-established analytical technique with a long research history. Many applications have been reported in various fields, such as in the environmental, archeological, biological, and forensic sciences as well as in industry. This is because XRF has a unique advantage of being a nondestructive analytical tool with good precision for quantitative analysis. Recent advances in XRF analysis have been realized by the development of new x-ray optics and x-ray detectors. Advanced x-ray focusing optics enables the making of a micro x-ray beam, leading to micro-XRF analysis and XRF imaging. A confocal micro-XRF technique has been applied for the visualization of elemental distributions inside the samples. This technique was applied for liquid samples and for monitoring chemical reactions such as the metal corrosion of steel samples in the NaCl solutions. In addition, a principal component analysis was applied for reducing the background intensity in XRF spectra obtained during XRF mapping, leading to improved spatial resolution of confocal micro-XRF images. In parallel, the authors have proposed a wavelength dispersive XRF (WD-XRF) imaging spectrometer for a fast elemental imaging. A new two dimensional x-ray detector, the Pilatus detector was applied for WD-XRF imaging. Fast XRF imaging in 1 s or even less was demonstrated for Euro coins and industrial samples. In this review paper, these recent advances in laboratory-based XRF imaging, especially in a laboratory setting, will be introduced.

  5. Probing symmetry and symmetry breaking in resonant soft-x-ray fluorescence spectra of molecules

    SciTech Connect

    Glans, P.; Gunnelin, K.; Guo, J.

    1997-04-01

    Conventional non-resonant soft X-ray emission brings about information about electronic structure through its symmetry and polarization selectivity, the character of which is governed by simple dipole rules. For centro-symmetric molecules with the emitting atom at the inversion center these rules lead to selective emission through the required parity change. For the more common classes of molecules which have lower symmetry or for systems with degenerate core orbitals (delocalized over identical sites), it is merely the local symmetry selectivity that provides a probe of the local atomic orbital contribution to the molecular orbital. For instance, in X-ray spectra of first row species the intensities essentially map the p-density at each particular atomic site, and, in a molecular orbital picture, the contribution of the local p-type atomic orbitals in the LCAO description of the molecular orbitals. The situation is different for resonant X-ray fluorescence spectra. Here strict parity and symmetry selectivity gives rise to a strong frequency dependence for all molecules with an element of symmetry. In addition to symmetry selectivity the strong frequency dependence of resonant X-ray emission is caused by the interplay between the shape of a narrow X-ray excitation energy function and the lifetime and vibrational broadenings of the resonantly excited core states. This interplay leads to various observable effects, such as linear dispersion, resonance narrowing and emission line (Stokes) doubling. Also from the point of view of polarization selectivity, the resonantly excited X-ray spectra are much more informative than the corresponding non-resonant spectra. Examples are presented for nitrogen, oxygen, and carbon dioxide molecules.

  6. Airborne particles in the Miyagi Museum of Art in Sendai, Japan, studied by electron probe X-ray microanalysis and energy dispersive X-ray fluorescence analysis.

    PubMed

    Injuk, Jasna; Osán, Janos; Van Grieken, René; Tsuji, Kouichi

    2002-05-01

    The presented work provides baseline data on the existing airborne conditions in the Miyagi Museum of Art in Sendai, Japan, during the summer of 2000. The chemical composition, size and indoor and outdoor origin of the suspended particulate matter were identified using a number of advanced X-ray techniques, such as Electron Probe X-Ray Microanalysis (EPXMA) and Energy Dispersive X-Ray Fluorescence Analysis (EDXRF). Our results, to the best of our knowledge, represent the first detailed study of the chemical nature of the indoor particulate matter in a Japanese museum and, as such, may contribute to future improvements of the air quality inside museums and to the lasting conservation of works of art.

  7. Elemental mapping of biofortified wheat grains using micro X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Ramos, I.; Pataco, I. M.; Mourinho, M. P.; Lidon, F.; Reboredo, F.; Pessoa, M. F.; Carvalho, M. L.; Santos, J. P.; Guerra, M.

    2016-06-01

    Micro X-ray fluorescence has been used to obtain elemental maps of biofortified wheat grains. Two varieties of wheat were used in the study, Triticum aestivum L. and Triticum durum desf. Two treatments, with different nutrient concentration, were applied to the plants during the whole plant growth cycle. From the obtained elemental maps it was possible to extract information regarding the plant's physiological processes under the biofortification procedures. Both macro and micronutrients were mapped, providing useful insight into the posterior food processing mechanisms of this biofortified staple food. We have also shown that these kind of studies can now be performed with laboratory benchtop apparatus, rather than using synchrotron radiation, increasing the overall attractiveness of micro X-ray fluorescence in the study of highly heterogeneous biological samples.

  8. Development of total uranium analytical method by L x-ray fluorescence

    SciTech Connect

    Dewberry, R.A.

    1996-09-18

    This paper describes development of an L x-ray fluorescence technique to perform total uranium analysis using an internal excitation source which is added directly to the sample. The method has been demonstrated with synthetic U samples in the limited concentration range of 1g/l to 15g/l, and provides the advantages of simplicity, involving no mechanical parts which would normally be found in an external excitation source. Total uranium is determined by counting L x-rays fluoresced by a microCurie level spike of Cd-109 added directly to the sample and without shielding the excitation source from the detector. A method for correction of sample self-absorption is included in the analysis.

  9. Application of the Total Reflection X-ray Fluorescence technique to trace elements determination in tobacco

    NASA Astrophysics Data System (ADS)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2008-12-01

    Many studies have identified an important number of toxic elements along with organic carcinogen molecules and radioactive isotopes in tobacco. In this work we have analyzed by Total Reflection X-Ray Fluorescence 9 brands of cigarettes being manufactured and distributed in the Mexican market. Two National Institute of Standards and Technology standards and a blank were equally treated at the same time. Results show the presence of some toxic elements such as Pb and Ni. These results are compared with available data for some foreign brands, while their implications for health are discussed. It can be confirmed that the Total Reflection X-Ray Fluorescence method provides precise (reproducible) and accuracy (trueness) data for 15 elements concentration in tobacco samples.

  10. Application of X-ray Fluorescence Spectroscopy in Analysis of Oil Paint Pigments

    NASA Astrophysics Data System (ADS)

    Major, Cassandra; Formica, Sarah

    2011-10-01

    X-ray Fluorescence (XRF) spectroscopy is a rapid, noninvasive technique for both detecting and identifying chemical elements within a given sample. At North Georgia College and State University, a sealed tube x-ray source and slightly focusing polycapillary optic are used in nondestructive XRF analysis of oil paint pigments. Oil paints contain both organic and inorganic matter, and the inorganic ingredients such as titanium, vanadium, iron, zinc, and other elements are easily detected by XRF, which can be used to uniquely differentiate between various paint pigments. To calibrate the XRF system for paint color identification, six different colors of oil paint were fluoresced and identified based off of their characteristic spectra. By scanning the paint sample in two dimensions, the characteristic XRF spectra obtained were compiled to produce an XRF replica of the painting.

  11. From papyrus to paper: Elemental characterization by X-ray fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Manso, M.; Costa, M.; Carvalho, M. L.

    2007-09-01

    The use of the elemental composition, determined by energy dispersive X-ray fluorescence (EDXRF), to characterize ancient and modern papyrus and parchment, and newspaper from three different years is reported. The concentrations of S, Cl, K, Ca, Ti, Mn, Fe, Cu, Zn, Ga, As, Br, Rb, Sr, Ba and Pb were determined in these samples in order to proceed to its characterization. From this work, we can conclude that the obtained results allow distinguishing modern and ancient documents by its elemental amount. It was observed, with few exceptions, that the modern samples present lower elemental concentration than the older ones. Furthermore, in the newspaper samples the number of detected elements depends on the newspaper's age, and decreases from the oldest (1919) to the most recent (2005). X-ray fluorescence spectrometry is a good elemental technique with the main advantage of being non-destructive, which makes it the perfect tool for the elemental analysis of cultural heritage.

  12. [Measurement and analysis of lead in soil using X-ray fluorescence spectroscopy].

    PubMed

    Zhang, Rong; Zhang, Yu-Jun; Zhang, Wei; Chen, Dong; Yu, Xiao-Ya; Gao, Yan-Wei

    2013-02-01

    The present paper analyzed the characteristics of X-ray fluorescence spectroscopy (XRF) of metal element lead in soil using the NITON XLt793 portable X-ray fluorescence spectra of heavy metal analyzer under laboratory conditions. The characteristic spectral lines of L(alpha) (energy: 10. 55 keV) and L(beta) (energy: 12. 61 keV) with different matrix elements were selected respectively for lead in the experiment. By measuring the intensities of the characteristic spectral line with different Pb concentration, the results demonstrate that the relation between concentration [mass fraction 10 x 10(-6) - 1 800 x 10(-6)] of Pb element and the intensity of the characteristic spectrum is well linear. The calibration curve of Pb was plotted based on the different concentration measurement results, and the limit of detection of 7.89 x 10(-6) was obtained for Pb in soil.

  13. X-ray fluorescence/Auger-electron coincidence spectroscopy of vacancy cascades in atomic argon

    SciTech Connect

    Arp, U.; LeBrun, T.; Southworth, S.H.; Jung, M.; MacDonald, M.A.

    1996-12-01

    Argon L{sub 2.3}-M{sub 2.3}M{sub 2.3} Auger-electron spectra were measured in coincidence with K{alpha} fluorescent x-rays in studies of Ar K-shell vacancy decays at several photon energies above the K-threshold and on the 1s-4p resonance in atomic argon. The complex spectra recorded by conventional electron spectroscopy are greatly simplified when recorded in coincidence with fluorescent x-rays, allowing a more detailed analysis of the vacancy cascade process. The resulting coincidence spectra are compared with Hartree-Fock calculations which include shake-up transitions in the resonant case. Small energy shifts of the coincidence electron spectra are attributed to post-collision interaction with 1s photoelectrons.

  14. X-ray fluorescence analysis of soft materials using needle-type collimators enabling greater tolerance in analysis depth

    NASA Astrophysics Data System (ADS)

    Tsuji, Kouichi; Matsuda, Akinori; Nakano, Kazuhiko; Okhrimovskyy, Andriy

    2006-04-01

    A simple micro-X-ray fluorescence (XRF) method was proposed by using commercially available injection needles. Two needles were arranged in confocal configuration inside the sample. One injection needle, which was connected directly to an X-ray tube, was used as an X-ray guide to irradiate X-rays into the sample. Another needle, which was also inserted into the sample, was used to detect the X-ray fluorescence excited inside the sample. From the beam size, the analyzing volume was evaluated to be 0.24 mm 3. Therefore, the X-ray fluorescence emitted from a micro region inside the sample could be detected, although this method can only be applied for soft samples. It was demonstrated that the X-ray fluorescence of Zn in a gelatin sample could be measured, and a good linear relationship was obtained for this element. X-ray fluorescence from an oyster sample was also successfully measured by using the injection needles collimator system.

  15. Macro and micro full field x-ray fluorescence with an X-ray pinhole camera presenting high energy and high spatial resolution.

    PubMed

    Romano, Francesco Paolo; Caliri, Claudia; Cosentino, Luigi; Gammino, Santo; Giuntini, Lorenzo; Mascali, David; Neri, Lorenzo; Pappalardo, Lighea; Rizzo, Francesca; Taccetti, Francesco

    2014-11-01

    This work describes a tabletop (50 cm × 25 cm × 25 cm) full field X-ray pinhole camera (FF-XPC) presenting high energy- and high spatial-resolution. The FF-XPC consists of a conventional charge-coupled device (CCD) detector coupled, in a coaxial geometry, to a pinhole collimator of small diameter. The X-ray fluorescence (XRF) is induced on the samples with an external low-power X-ray tube. The use of the CCD as an energy dispersive X-ray detector was obtained by adopting a multi-image acquisition in single photon counting and by developing a processing algorithm to be applied in real-time to each of the acquired image-frames. This approach allowed the measurement of X-ray spectra with an energy resolution down to 133 eV at the reference value of 5.9 keV. The detection of the X-ray fluorescence through the pinhole-collimator allowed the two-dimensional elemental mapping of the irradiated samples. Two magnifications (M), determined by the relative sample-pinhole-CCD distances, are used in the present setup. A low value of M (equal to 0.35×) allows the macro-FF-XRF of large area samples (up to 4 × 4 cm(2)) with a spatial resolution down to 140 μm; a large magnification (M equal to 6×) is used for the micro-FF-XRF of small area samples (2.5 × 2.5 mm(2)) with a spatial resolution down to 30 μm.

  16. Analytical characterization of a new mobile X-ray fluorescence and X-ray diffraction instrument combined with a pigment identification case study

    NASA Astrophysics Data System (ADS)

    Van de Voorde, Lien; Vekemans, Bart; Verhaeven, Eddy; Tack, Pieter; De Wolf, Robin; Garrevoet, Jan; Vandenabeele, Peter; Vincze, Laszlo

    2015-08-01

    A new, commercially available, mobile system combining X-ray diffraction and X-ray fluorescence has been evaluated which enables both elemental analysis and phase identification simultaneously. The instrument makes use of a copper or molybdenum based miniature X-ray tube and a silicon-Pin diode energy-dispersive detector to count the photons originating from the samples. The X-ray tube and detector are both mounted on an X-ray diffraction protractor in a Bragg-Brentano θ:θ geometry. The mobile instrument is one of the lightest and most compact instruments of its kind (3.5 kg) and it is thus very useful for in situ purposes such as the direct (non-destructive) analysis of cultural heritage objects which need to be analyzed on site without any displacement. The supplied software allows both the operation of the instrument for data collection and in-depth data analysis using the International Centre for Diffraction Data database. This paper focuses on the characterization of the instrument, combined with a case study on pigment identification and an illustrative example for the analysis of lead alloyed printing letters. The results show that this commercially available light-weight instrument is able to identify the main crystalline phases non-destructively, present in a variety of samples, with a high degree of flexibility regarding sample size and position.

  17. X-ray fluorescence analysis of metal concentration in an alloy electroplating bath

    SciTech Connect

    Hines, R.A.

    1980-06-01

    An energy-dispersive x-ray fluorescence analysis system has been developed for rapid, simultaneous analysis of gold and copper concentrations in an aqueous electroplating bath. The speed and repeatability of the system make it well suited for in-process control. Data collection and reduction are automatic. The analysis requires less than 10 minutes from taking the sample to printing the gold and copper concentrations.

  18. Quantitative X-ray fluorescence analysis of As-Se glasses and films

    NASA Astrophysics Data System (ADS)

    Bordovskiĭ, G. A.; Marchenko, A. V.; Seregin, P. P.; Smirnova, N. N.; Terukov, E. I.

    2009-11-01

    The concentrations of arsenic and selenium in As100 - x Se x glassy alloys and related films have been determined by the X-ray fluorescence spectroscopy using the external standard technique. It is demonstrated that the proposed approach allows the compositions of As100 - x Se x glasses and films to be quantitatively determined with an accuracy of Δ x = ±0.02.

  19. Evaluation of Portable X-Ray Fluorescence (XRF) Analyzer for Zirconium-Thickness Measurements

    SciTech Connect

    Glenn Moore

    2013-09-01

    This Technical Evaluation Report provides details of preliminary testing/experiments performed using a handheld X-ray fluorescence analyzer. The analyzer will be utilized in upcoming fuel-foil-rolling optimization studies at the INL. The studies are being performed in support of DOE’s Office of Global Threat Reduction -- Reactor Conversion Subprogram. Details of the equipment used, operating parameters, and measurement results are provided in this report.

  20. Cosputtered composition-spread reproducibility established by high-throughput x-ray fluorescence

    SciTech Connect

    Gregoire, John M.; Dale, Darren; Kazimirov, Alexander; DiSalvo, Francis J.; Dover, R. Bruce van

    2010-09-15

    We describe the characterization of sputtered yttria-zirconia composition spread thin films by x-ray fluorescence (XRF). We also discuss our automated analysis of the XRF data, which was collected in a high throughput experiment at the Cornell High Energy Synchrotron Source. The results indicate that both the composition reproducibility of the library deposition and the composition measurements have a precision of better than 1 atomic percent.

  1. Interference of fluorescence x-rays and coherent excitation of core levels

    SciTech Connect

    Ma, Y. |; Blume, M.

    1994-08-01

    The question of coherence in inelastic x-ray absorption and fluorescence processes among identical interacting atoms is studied using a simple diatomic model. Conditions for the coherence are discussed in terms of energy scales, such as the core hole life-time, instrument energy resolutions, and the splitting of the electronic levels. As in the classical Young double-slit experiment, the primary requirement is that it be impossible to determine which atom has undergone the excitation-decay process.

  2. Clumpy tori around type II active galactic nuclei as revealed by X-ray fluorescent lines

    NASA Astrophysics Data System (ADS)

    Liu, Jiren; Liu, Yuan; Li, Xiaobo; Xu, Weiwei; Gou, Lijun; Cheng, Cheng

    2016-06-01

    The reflection spectrum of a torus around an active galactic nucleus (AGN) is characterized by X-ray fluorescent lines, which are most prominent for type II AGNs. A clumpy torus allows photons reflected from the back-side of the torus to leak through the front regions that are free of obscuration. The observed X-ray fluorescent lines are therefore sensitive to the clumpiness of the torus. We analysed a sample of type II AGNs observed with the Chandra High Energy Transmission Grating Spectrometer (HETGS), and measured the fluxes for the Si Kα and Fe Kα lines. The measured Fe Kα/Si Kα ratios, spanning a range between 5 and 60, are far smaller than the ratios predicted from simulations of smooth tori, indicating that the tori of the studied sources have clumpy distributions rather than smooth ones. We compared the measured Fe Kα/Si Kα ratios with simulation results of clumpy tori. The Circinus galaxy has a Fe Kα/Si Kα ratio of ˜60, which is close to the simulation results for N = 5, where N is the average number of clumps along the line of sight. The Fe Kα/Si Kα ratios of the other sources are all below the simulation results for N = 2. Overall, this shows that the non-Fe fluorescent lines in the soft X-ray band are a potentially powerful probe of the clumpiness of tori around AGNs.

  3. A method of measuring gold nanoparticle concentrations by x-ray fluorescence for biomedical applications

    SciTech Connect

    Wu Di; Li Yuhua; Wong, Molly D.; Liu Hong

    2013-05-15

    Purpose: This paper reports a technique that enables the quantitative determination of the concentration of gold nanoparticles (GNPs) through the accurate detection of their fluorescence radiation in the diagnostic x-ray spectrum. Methods: Experimentally, x-ray fluorescence spectra of 1.9 and 15 nm GNP solutions are measured using an x-ray spectrometer, individually and within chicken breast tissue samples. An optimal combination of excitation and emission filters is determined to segregate the fluorescence spectra at 66.99 and 68.80 keV from the background scattering. A roadmap method is developed that subtracts the scattered radiation (acquired before the insertion of GNP solutions) from the signal radiation acquired after the GNP solutions are inserted. Results: The methods effectively minimize the background scattering in the spectrum measurements, showing linear relationships between GNP solutions from 0.1% to 10% weight concentration and from 0.1% to 1.0% weight concentration inside a chicken breast tissue sample. Conclusions: The investigation demonstrated the potential of imaging gold nanoparticles quantitatively in vivo for in-tissue studies, but future studies will be needed to investigate the ability to apply this method to clinical applications.

  4. A new workflow for x-ray fluorescence tomography: MAPStoTomoPy

    NASA Astrophysics Data System (ADS)

    Hong, Young Pyo; Chen, Si; Jacobsen, Chris

    2015-09-01

    X-ray fluorescence tomography involves the acquisition of a series of 2D x-ray fluorescence datasets between which a specimen is rotated. At the Advanced Photon Source at Argonne National Laboratory, the workflow at beamlines 2-ID-E and 21-ID-D (the Bionanoprobe, a cryogenic microscope system) has included the use of the program MAPS for obtaining elemental concentrations from 2D images, and the program TomoPy which was developed to include several tomographic reconstruction methods for x-ray transmission data. In the past, fluorescence projection images from an individual chemical element were hand-assembled into a 3D dataset for reconstruction using interactive tools such as ImageJ. We describe here the program MAPSToTomoPy, which provides a graphical user interface (GUI) to control a workflow between MAPS and TomoPy, with tools for visualizing the sinograms of projection image sequences from particular elements and to use these to help correct misalignments of the rotation axis. The program also provides an integrated output of the 3D distribution of the detected elements for subsequent 3D visualization packages.

  5. A New Workflow for x-ray fluorescence tomography: MAPSToTomoPy

    PubMed Central

    Hong, Young Pyo; Chen, Si; Jacobsen, Chris

    2016-01-01

    X-ray fluorescence tomography involves the acquisition of a series of 2D x-ray fluorescence datasets between which a specimen is rotated. At the Advanced Photon Source at Argonne National Laboratory, the workflow at beamlines 2-ID-E and 21-ID-D (the Bionanoprobe, a cryogenic microscope system) has included the use of the program MAPS for obtaining elemental concentrations from 2D images, and the program TomoPy which was developed to include several tomographic reconstruction methods for x-ray transmission data. In the past, fluorescence projection images from an individual chemical element were hand-assembled into a 3D dataset for reconstruction using interactive tools such as ImageJ. We describe here the program MAPSToTomoPy, which provides a graphical user interface (GUI) to control a workflow between MAPS and TomoPy, with tools for visualizing the sinograms of projection image sequences from particular elements and to use these to help correct misalignments of the rotation axis. The program also provides an integrated output of the 3D distribution of the detected elements for subsequent 3D visualization packages. PMID:27103755

  6. Portable apparatus for in situ x-ray diffraction and fluorescence analyses of artworks.

    PubMed

    Eveno, Myriam; Moignard, Brice; Castaing, Jacques

    2011-10-01

    A portable X-ray fluorescence/X-ray diffraction (XRF/XRD) system for artwork studies has been designed constructed and tested. It is based on Debye Scherrer XRD in reflection that takes advantage of many recent improvements in the handling of X-rays (polycapillary optics; advanced two-dimensional detection). The apparatus is based on a copper anode air cooled X-ray source, and the XRD analysis is performed on a 5-20 μm thick layer from the object surface. Energy dispersive XRF elemental analysis can be performed at the same point as XRD, giving elemental compositions that support the interpretation of XRD diagrams. XRF and XRD analyses were tested to explore the quality and the limits of the analytical technique. The XRD diagrams are comparable in quality with diagrams obtained with conventional laboratory equipment. The mineral identification of materials in artwork is routinely performed with the portable XRF-XRD system. Examples are given for ceramic glazes containing crystals and for paintings where the determination of pigments is still a challenge for nondestructive analysis. For instance, lead compounds that provide a variety of color pigments can be easily identified as well as a pigment such as lapis lazuli that is difficult to identify by XRF alone. More than 70 works of art have been studied in situ in museums, monuments, etc. In addition to ceramics and paintings, these works include bronzes, manuscripts, etc., which permit improvement in the comprehension of ancient artistic techniques. PMID:21615981

  7. X-ray fluorescence analysis of cultural artefacts — Applications to the Czech heritage

    NASA Astrophysics Data System (ADS)

    Trojek, T.; Musílek, L.; Čechák, T.

    2014-02-01

    X-ray florescence analysis is an excellent non-destructive tool for analysing the elemental composition of materials in a wide range of works of art. The Department of Dosimetry and Application of Ionising Radiation at CTU-FNSPE has used radionuclide or X-ray tube excited energy dispersive X-ray fluorescence for many kinds of artefacts, including frescos, paintings, manuscripts, metal sculptures and other objects, ceramics, jewellery, various archaeological finds, etc. The method used is more or less "traditional", i.e., semiconductor spectrometry of excited X-rays, with some optional choices—capillary optics for collimation of exciting beams and two-dimensional scanning. The "hardware" complex is supplemented by techniques for estimating the depth distribution of measured elements, for suppressing surface effects, for in situ non-contact measurements, etc. Extending the measurable range to lighter elements and decreasing the detection limits is one of the achievements that has been attained by improving the instrumentation and techniques that are used. This paper gives a brief review of works carried out at the Department of Dosimetry and Application of Ionising Radiation at CTU-FNSPE.

  8. X-ray optics for scanning fluorescence microscopy and other applications

    SciTech Connect

    Ryon, R.W.; Warburton, W.K.

    1992-05-01

    Scanning x-ray fluorescence microscopy is analogous to scanning electron microscopy. Maps of chemical element distribution are produced by scanning with a very small x-ray beam. Goal is to perform such scanning microscopy with resolution in the range of <1 to 10 {mu}m, using standard laboratory x-ray tubes. We are investigating mirror optics in the Kirkpatrick-Baez (K-B) configuration. K-B optics uses two curved mirrors mounted orthogonally along the optical axis. The first mirror provides vertical focus, the second mirror provides horizontal focus. We have used two types of mirrors: synthetic multilayers and crystals. Multilayer mirrors are used with lower energy radiation such as Cu K{alpha}. At higher energies such as Ag K{alpha}, silicon wafers are used in order to increase the incidence angles and thereby the photon collection efficiency. In order to increase the surface area of multilayers which reflects x-rays at the Bragg angle, we have designed mirrors with the spacing between layers graded along the optic axis in order to compensate for the changing angle of incidence. Likewise, to achieve a large reflecting surface with silicon, the wafers are placed on a specially designed lever arm which is bent into a log spiral by applying force at one end. In this way, the same diffracting angle is maintained over the entire surface of the wafer, providing a large solid angle for photon collection.

  9. Handheld X-ray Fluorescence Spectrometers: Radiation Exposure Risks of Matrix-Specific Measurement Scenarios.

    PubMed

    Rouillon, Marek; Kristensen, Louise J; Gore, Damian B

    2015-07-01

    This study investigates X-ray intensity and dispersion around handheld X-ray fluorescence (XRF) instruments during the measurement of a range of sample matrices to establish radiation exposure risk during operation. Four handheld XRF instruments representing three manufacturers were used on four smooth, flat-lying materials of contrasting matrix composition. Dose rates were measured at 10, 20, 30, and 40 cm intervals every 30° around the instrument at 0 and 45° from the horizontal, as well as vertically from the instrument screen. The analysis of polyethylene recorded dose rates 156 times higher (on average) than steel measurements and 34 times higher than both quartz sand and quartz sandstone. A worst-case exposure scenario was assumed where a user analyses a polyethylene material at arms reach for 1 h each working day for one year. This scenario resulted in an effective body dose of 73.5 μSv, equivalent to three to four chest X-rays (20 μSv) a year, 20 times lower than the average annual background radiation exposure in Australia and well below the annual exposure limit of 1 mSv for non-radiation workers. This study finds the advantages of using handheld XRF spectrometers far outweighs the risk of low radiation exposure linked to X-ray scattering from samples. PMID:26037330

  10. Portable apparatus for in situ x-ray diffraction and fluorescence analyses of artworks.

    PubMed

    Eveno, Myriam; Moignard, Brice; Castaing, Jacques

    2011-10-01

    A portable X-ray fluorescence/X-ray diffraction (XRF/XRD) system for artwork studies has been designed constructed and tested. It is based on Debye Scherrer XRD in reflection that takes advantage of many recent improvements in the handling of X-rays (polycapillary optics; advanced two-dimensional detection). The apparatus is based on a copper anode air cooled X-ray source, and the XRD analysis is performed on a 5-20 μm thick layer from the object surface. Energy dispersive XRF elemental analysis can be performed at the same point as XRD, giving elemental compositions that support the interpretation of XRD diagrams. XRF and XRD analyses were tested to explore the quality and the limits of the analytical technique. The XRD diagrams are comparable in quality with diagrams obtained with conventional laboratory equipment. The mineral identification of materials in artwork is routinely performed with the portable XRF-XRD system. Examples are given for ceramic glazes containing crystals and for paintings where the determination of pigments is still a challenge for nondestructive analysis. For instance, lead compounds that provide a variety of color pigments can be easily identified as well as a pigment such as lapis lazuli that is difficult to identify by XRF alone. More than 70 works of art have been studied in situ in museums, monuments, etc. In addition to ceramics and paintings, these works include bronzes, manuscripts, etc., which permit improvement in the comprehension of ancient artistic techniques.

  11. Cancer diagnosis using a conventional x-ray fluorescence camera with a cadmium-telluride detector

    NASA Astrophysics Data System (ADS)

    Sato, Eiichi; Enomoto, Toshiyuki; Hagiwara, Osahiko; Abudurexiti, Abulajiang; Sato, Koetsu; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2011-10-01

    X-ray fluorescence (XRF) analysis is useful for mapping various atoms in objects. Bremsstrahlung X-rays are selected using a 3.0 mm-thick aluminum filter, and these rays are absorbed by indium, cerium and gadolinium atoms in objects. Then XRF is produced from the objects, and photons are detected by a cadmium-telluride detector. The Kα photons are discriminated using a multichannel analyzer, and the number of photons is counted by a counter card. The objects are moved and scanned by an x-y stage in conjunction with a two-stage controller, and X-ray images obtained by atomic mapping are shown on a personal computer monitor. The scan steps of the x and y axes were both 2.5 mm, and the photon-counting time per mapping point was 0.5 s. We carried out atomic mapping using the X-ray camera, and Kα photons from cerium and gadolinium atoms were produced from cancerous regions in nude mice.

  12. Effect of regolith on planetary X-ray fluorescence spectroscopy: laboratory and numerical studies

    NASA Astrophysics Data System (ADS)

    Naranen, Jyri; Carpenter, James; Parviainen, Hannu; Muinonen, Karri

    Fluorescent X-rays from the surfaces of airless planetary bodies in the inner solar system have been measured by instruments on several spacecraft. X-ray emission follows photoionisation by incident solar X-rays and charged particles and reveals the elemental composition of the surface. Analyses of X-ray spectra obtained by orbiting spacecraft, use the relative intensities of elemental emission lines (e.g., Ca/Si, Fe/Si) to determine the geochemistry of the target body. Historically, the analysis of X-ray spectra has assumed that surfaces can be considered as homogeneous plane-parallel media. It has been shown, however, that relative line intensities are affected by the physical properties of the target surface (e.g. particle size distribution and packing density of the regolith) and the viewing and illumination geometry of observations. We describe experimental investigations into the effects of regolith properties on the line ratios measured by a nadir pointing (emergence angle 0° ) orbiting instrument, with with solar illumination angles in the range 25-75° from zenith. The planetary regolith analogue used in these experiments was a terrestrial, olivine rich basalt, which has been used by previous authors as an analogue to the lunar maria. The basalt samples were ground to powder and sieved to discriminate particles in the ranges, <75µm, 75-250µm, and 250-500µm. These separate powders were then pressed into solid pellets. The separation of particles with different sizes allows some determination of the effects due to changes in particle size. All measurements were made at pressures of less than 0.5 mbar to prevent absorption of fluorescent X-rays in air. The relative fluorescent line ratios of several major rock forming elements (K, Ca, Ti, Si) were measured. We find that for measurements made in a "nadir" pointing geometry, the measured spectrum becomes increasingly hard as illumination angle increases (i.e. X-ray lines at higher energies are enhanced

  13. Total reflection x-ray fluorescence: Determination of an optimum geometry

    SciTech Connect

    Koo, Y.M.; Chang, C.H.; Padmore, H.A.

    1997-04-01

    Total reflection X-Ray Fluorescence (TXRF) is a widely used technique in which the normal trace element detection capability of hard x-ray fluorescence (XRF) is enhanced by use of an x-ray reflective substrate. TXRF is more sensitive than normal photon induced XRF due to the reduction of the substrate scattering and fluorescence signals. This reduction comes about because in total external reflection, the photon field only penetrates about 20 {angstrom} into the surface, instead of typically 50 {mu}m for a silicon substrate at normal incidence for 10 KeV photons. The technique is used in many fields of trace element analysis, and is widely used in the determination of metal impurity concentrations on and in the surface of silicon wafers. The Semiconductor Industry Association roadmap (SIA) indicates a need for wafer contamination detection at the 10{sup 7}atoms/cm{sup 2} level in the next few years. Current commercial systems using rotating anode x-ray sources presently routinely operate with a sensitivity level of around 10{sup 10} atoms/cm{sup 2} and this has led to interest in the use of synchrotron radiation to extend the sensitivity by three orders of magnitude. The pioneering work of Pianetta and co-workers at SSRL has clearly shown that this should be possible, using a fully optimized source and detector. The purpose of this work is to determine whether ALS would be a suitable source for this type of highly sensitive wafer TXRF. At first look it appears improbable as the SSRL work used a high flux multipole wiggler source, and it is clear that the detected fluorescence for relevant concentrations is small. In addition, SSRL operates at 3.0 GeV rather than 1.9 GeV, and is therefore more naturally suited to hard x-ray experiments. The aim of this work was therefore to establish a theoretical model for the scattering and fluorescence processes, so that one could predict the differences between alternative geometries and select an optimum configuration.

  14. Monochromatic X-ray propagation in multi-Z media for imaging and diagnostics including Kα Resonance Fluorescence

    NASA Astrophysics Data System (ADS)

    Westphal, Maximillian; Lim, Sara; Nahar, Sultana; Pradhan, Anil

    2016-05-01

    Aimed at monochromatic X-ray imaging and therapy, broadband, monochromatic, and quasi-monochromatic X-ray sources and propagation through low and high-Z (HZ) media were studied with numerically and experimentally. Monte Carlo simulations were performed using the software package Geant4, and a new code Photx, to simulate X-ray image contrast, depth of penetration, and total attenuation. The data show that monochromatic and quasi-monochromatic X-rays achieve improved contrast at lower absorbed radiation doses compared to conventional broadband 120 kV or CT scans. Experimental quasi-monochromatic high-intensity laser-produced plasma sources and monochromatic synchrotron beam data are compared. Physical processes responsible for X-ray photoexcitation and absorption are numerically modelled, including a novel mechanism for accelerating Kα resonance fluorescence via twin monochromatic X-ray beam. Potential applications are medical diagnostics and high-Z material detection. Acknowledgement: Ohio Supercomputer Center, Columbus, OH.

  15. Simultaneous x-ray nano-ptychographic and fluorescence microscopy at the bionanoprobe

    NASA Astrophysics Data System (ADS)

    Chen, S.; Deng, J.; Vine, D. J.; Nashed, Y. S. G.; Jin, Q.; Peterka, T.; Jacobsen, C.; Vogt, S.

    2015-09-01

    Hard X-ray fluorescence (XRF) microscopy offers unparalleled sensitivity for quantitative analysis of most of the trace elements in biological samples, such as Fe, Cu, and Zn. These trace elements play critical roles in many biological processes. With the advanced nano-focusing optics, nowadays hard X-rays can be focused down to 30 nm or below and can probe trace elements within subcellular compartments. However, XRF imaging does not usually reveal much information on ultrastructure, because the main constituents of biomaterials, i.e. H, C, N, and O, have low fluorescence yield and little absorption contrast at multi-keV X-ray energies. An alternative technique for imaging ultrastructure is ptychography. One can record far-field diffraction patterns from a coherently illuminated sample, and then reconstruct the complex transmission function of the sample. In theory the spatial resolution of ptychography can reach the wavelength limit. In this manuscript, we will describe the implementation of ptychography at the Bionanoprobe (a recently developed hard XRF nanoprobe at the Advanced Photon Source) and demonstrate simultaneous ptychographic and XRF imaging of frozen-hydrated biological whole cells. This method allows locating trace elements within the subcellular structures of biological samples with high spatial resolution. Additionally, both ptychographic and XRF imaging are compatible with tomographic approach for 3D visualization.

  16. Dual x-ray fluorescence spectrometer and method for fluid analysis

    DOEpatents

    Wilson, Bary W.; Shepard, Chester L.

    2005-02-22

    Disclosed are an X-ray fluorescence (SRF) spectrometer and method for on-site and in-line determination of contaminant elements in lubricating oils and in fuel oils on board a marine vessel. An XRF source block 13 contains two radionuclide sources 16, 17 (e.g. Cd 109 and Fe 55), each oriented 180 degrees from the other to excite separate targets. The Cd 109 source 16 excites sample lube oil flowing through a low molecular weight sample line 18. The Fe 55 source 17 excites fuel oil manually presented to the source beam inside a low molecular weight vial 26 or other container. Two separate detectors A and B are arranged to detect the fluorescent x-rays from the targets, photons from the analyte atoms in the lube oil for example, and sulfur identifying x-rays from bunker fuel oil for example. The system allows both automated in-line and manual on-site analysis using one set of signal processing and multi-channel analyzer electronics 34, 37 as well as one computer 39 and user interface 43.

  17. The Monte Carlo modelling of in vivo x-ray fluorescence measurement of lead in tissue.

    PubMed

    Wallace, J D

    1994-10-01

    A Monte Carlo model has been developed, using the EGS4 code, to model the in vivo x-ray fluorescence (XRF) measurement of Pb in non-superficial bone/tissue. Unlike previous work in this field the current model incorporates a correction for Doppler broadening of the Compton scatter peak due to the electron momentum distribution of the medium (tissue/water) in which the photons are Compton scattered by convolving the Compton peak of the Monte Carlo generated spectrum with a modified Compton profile for water. This correction improves the agreement between the measured spectral shape obtained using an experimental in vivo x-ray fluorescence Pb analyser with a 109Cd/180 degrees source/geometry combination, measuring a bone phantom at depth in water and the generated spectral shape obtained from the equivalent Monte Carlo model. The model enables improved estimates to be made of the spectral background beneath the Pb Kalpha1 and Kalpha2 x-ray peaks compared with estimates based on simpler models that assume that Compton interactions are with 'free' electrons and hence permits better optimization of in vivo analyser system design. PMID:15551542

  18. Determination of minor and trace elements in kidney stones by x-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Srivastava, Anjali; Heisinger, Brianne J.; Sinha, Vaibhav; Lee, Hyong-Koo; Liu, Xin; Qu, Mingliang; Duan, Xinhui; Leng, Shuai; McCollough, Cynthia H.

    2014-03-01

    The determination of accurate material composition of a kidney stone is crucial for understanding the formation of the kidney stone as well as for preventive therapeutic strategies. Radiations probing instrumental activation analysis techniques are excellent tools for identification of involved materials present in the kidney stone. In particular, x-ray fluorescence (XRF) can be very useful for the determination of minor and trace materials in the kidney stone. The X-ray fluorescence measurements were performed at the Radiation Measurements and Spectroscopy Laboratory (RMSL) of department of nuclear engineering of Missouri University of Science and Technology and different kidney stones were acquired from the Mayo Clinic, Rochester, Minnesota. Presently, experimental studies in conjunction with analytical techniques were used to determine the exact composition of the kidney stone. A new type of experimental set-up was developed and utilized for XRF analysis of the kidney stone. The correlation of applied radiation source intensity, emission of X-ray spectrum from involving elements and absorption coefficient characteristics were analyzed. To verify the experimental results with analytical calculation, several sets of kidney stones were analyzed using XRF technique. The elements which were identified from this techniques are Silver (Ag), Arsenic (As), Bromine (Br), Chromium (Cr), Copper (Cu), Gallium (Ga), Germanium (Ge), Molybdenum (Mo), Niobium (Nb), Rubidium (Rb), Selenium (Se), Strontium (Sr), Yttrium (Y), Zirconium (Zr). This paper presents a new approach for exact detection of accurate material composition of kidney stone materials using XRF instrumental activation analysis technique.

  19. Development of a single-cell X-ray fluorescence flow cytometer.

    PubMed

    Crawford, Andrew M; Kurecka, Patrick; Yim, Tsz Kwan; Kozemchak, Claire; Deb, Aniruddha; Dostál, Lubomír; Sun, Cheng Jun; Brewe, Dale L; Barrea, Raul; Penner-Hahn, James E

    2016-07-01

    An X-ray fluorescence flow cytometer that can determine the total metal content of single cells has been developed. Capillary action or pressure was used to load cells into hydrophilic or hydrophobic capillaries, respectively. Once loaded, the cells were transported at a fixed vertical velocity past a focused X-ray beam. X-ray fluorescence was then used to determine the mass of metal in each cell. By making single-cell measurements, the population heterogeneity for metals in the µM to mM concentration range on fL sample volumes can be directly measured, a measurement that is difficult using most analytical methods. This approach has been used to determine the metal composition of 936 individual bovine red blood cells (bRBC), 31 individual 3T3 mouse fibroblasts (NIH3T3) and 18 Saccharomyces cerevisiae (yeast) cells with an average measurement frequency of ∼4 cells min(-1). These data show evidence for surprisingly broad metal distributions. Details of the device design, data analysis and opportunities for further sensitivity improvement are described. PMID:27359138

  20. A new method for x-ray fluorescence analysis of contaminated material. Final Report

    SciTech Connect

    Grodzins, Lee; Niland, John

    2002-05-23

    Niton has successfully completed the objectives of the Phase II program to build a hand-held, x-ray fluorescent analyzer optimized for DOE decontamination and decommissioning activities in the field. A two-pound x-ray fluorescence analyzer was developed that contains 3 radioactive sources, emitting 3 widely spaced monochromatic x-rays, to give the lowest detection limits for the full range of toxic elements, from chromium to plutonium. A rapid, fundamental- parameters algorithm was developed that yields quantitative results in less than 1 second. High-resolution silicon drift detectors and silicon PIN diodes give excellent efficiency and speed. These results from Phase II have been introduced into the XL 300, 700 and 800 commercial products series. More than 800 of these instruments, yielding revenues of more than $20 million dollars, have been sold since the first 3-source instrument was introduced in 1998. A direct consequence of the Phase II funding has been the growth of Niton from 20 people to its present size of 60.

  1. Measurement of plutonium in spent nuclear fuel by self-induced x-ray fluorescence

    SciTech Connect

    Hoover, Andrew S; Rudy, Cliff R; Tobin, Steve J; Charlton, William S; Stafford, A; Strohmeyer, D; Saavadra, S

    2009-01-01

    Direct measurement of the plutonium content in spent nuclear fuel is a challenging problem in non-destructive assay. The very high gamma-ray flux from fission product isotopes overwhelms the weaker gamma-ray emissions from plutonium and uranium, making passive gamma-ray measurements impossible. However, the intense fission product radiation is effective at exciting plutonium and uranium atoms, resulting in subsequent fluorescence X-ray emission. K-shell X-rays in the 100 keV energy range can escape the fuel and cladding, providing a direct signal from uranium and plutonium that can be measured with a standard germanium detector. The measured plutonium to uranium elemental ratio can be used to compute the plutonium content of the fuel. The technique can potentially provide a passive, non-destructive assay tool for determining plutonium content in spent fuel. In this paper, we discuss recent non-destructive measurements of plutonium X-ray fluorescence (XRF) signatures from pressurized water reactor spent fuel rods. We also discuss how emerging new technologies, like very high energy resolution microcalorimeter detectors, might be applied to XRF measurements.

  2. Scanning protein analysis of electrofocusing gels using X-ray fluorescence.

    PubMed

    Matsuyama, Satoshi; Matsunaga, Akihiro; Sakamoto, Shinichi; Iida, Yutaka; Suzuki, Yoshinari; Ishizaka, Yukihito; Yamauchi, Kazuto; Ishikawa, Tetsuya; Shimura, Mari

    2013-05-01

    Recently, "metallomics," in addition to genomics and proteomics, has become a focus as a novel approach to identify sensitive fluctuations in homeostasis that accompany metabolic processes, such as stress responses, differentiation, and proliferation. Cellular elements and associated protein behavior provide important clues for understanding cellular and disease mechanism(s). It is important to develop a system for measuring the native status of the protein. In this study, we developed an original freeze-dried electrofocusing native gel over polyimide film (native-gel film) for scanning protein analysis using synchrotron radiation excited X-ray fluorescence (SPAX). To our knowledge, this is the first report detailing the successful mapping of metal-associated proteins of electrofocusing gels using X-ray fluorescence. SPAX can provide detection sensitivity equivalent to that of LA-ICP-MS. In addition to this increased sensitivity, SPAX has the potential to be combined with other X-ray spectroscopies. Our system is useful for further applications in proteomics investigating cellular element-associated protein behaviors and disease mechanisms.

  3. In Vivo X-Ray Fluorescence Microtomographic Imaging of Elements in Single-Celled Fern Spores

    SciTech Connect

    Hirai, Yasuharu; Yoneyama, Akio; Hisada, Akiko; Uchida, Kenko

    2007-01-19

    We have observed in vivo three-dimensional distributions of constituent elements of single-celled spores of the fern Adiantum capillus-veneris using an X-ray fluorescence computed microtomography method. The images of these distributions are generated from a series of slice data, each of which is acquired by a sample translation-rotation method. An incident X-ray microbeam irradiates the sample with a spot size of 1 {mu}m. The high Ca concentration in the testa and the localized and overlapping Fe and Zn concentrations inside the spore are shown in three-dimensional images. The K concentration is high throughout the cell, and there are localized regions of higher density. The atomic number densities of these elements in the testa and inside the cell in a tomographic slice are estimated with a resolution of about 1 {mu}m.

  4. Reverse engineering the ancient ceramic technology based on X-ray fluorescence spectromicroscopy

    SciTech Connect

    Sciau, Philippe; Leon, Yoanna; Goudeau, Philippe; Fakra, Sirine C.; Webb, Sam; Mehta, Apurva

    2011-07-06

    We present results of X-ray fluorescence (XRF) microprobe analyses of ancient ceramic cross-sections aiming at deciphering the different firing protocols used for their production. Micro-focused XRF elemental mapping, Fe chemical mapping and Fe K-edge X-ray absorption near edge structure spectroscopy were performed on pre-sigillata ceramics from southern Gaul, and terra Sigillata vessels from Italy and southern Gaul. Pieces from the different workshops and regions showed significant difference in the starting clay material, clay conditioning and kiln firing condition. By contrast, sherds from the same workshop exhibited more subtle differences and possible misfirings. Understanding the precise firing conditions and protocols would allow recreation of kilns for various productions. Furthermore, evolution and modification of kiln design would shed some light on how ancient potters devised solutions to diverse technological problems they encountered.

  5. Fluorescent X-Ray Computed Tomography towards Molecular Imaging: Proof-of-Concept Experiments

    SciTech Connect

    Yuasa, Tetsuya; Huo, Qingkai; Akatsuka, Takao; Takeda, Tohoru; Hyodo, Kazuyuki; Dilmanian, F. Avraham

    2009-03-10

    By means of fluorescent x-ray computed tomography (FXCT) one can detect and image a distribution of non-radioactive imaging agent, e.g., iodine, in a biomedical subject at a high spatial resolution, so it can be a novel molecular imaging modality. We have been studying an FXCT system using synchrotron radiation for in-vivo imaging brains of small animals such as mouse, or rat. For the purpose, we propose a fast FXCT imaging method based on the novel geometry. In this study, we prove the feasibility of this concept and investigate its imaging properties, including spatial and contrast resolutions and quantitativeness, by imaging an acrylic phantom and a normal mouse brain using a preliminary imaging system with monochromatic synchrotron x rays.

  6. X-ray fluorescence as a tool for investigating archaeological finds

    NASA Astrophysics Data System (ADS)

    Čechák, T.; Hložek, M.; Musílek, L.; Trojek, T.

    2007-09-01

    X-ray fluorescence analysis (XRFA) is an outstanding method for investigations of various objects of historic and cultural significance, as it is non-destructive, can be used without any sampling of the analysed artefacts and, if necessary, measurements can be carried out in situ. The laboratory at CTU FNSPE is equipped for XRFA with radionuclides 55Fe, 238Pu and 241Am and with a small X-ray tube (30 kV) as excitation sources, and with Si(Li) and Si-PIN semiconductor spectrometers for detecting XRF spectra. This paper deals with XRFA of archaeological finds. Practical examples are selected from investigations of ceramic objects from excavations in the Czech Republic.

  7. Use of x-ray fluorescence and diffraction techniques in studying ancient ceramics of Sri Lanka

    NASA Astrophysics Data System (ADS)

    Karunaratne, B. S. B.

    2012-07-01

    Ceramics were produced for centuries in Sri Lanka for various purposes. Ancient ceramic articles such as pottery, bricks, tiles, sewer pipes, etc, were made from naturally occurring raw materials. Use of X-ray fluorescence (XRF), X-ray diffraction (XRD) and Scanning Electron Microscopy (SEM) in characterizing of two ancient ceramic samples from two different archaeological sites in Sri Lanka is presented. The information obtained in this manner is used to figure out the ancient ceramic technology, particularly to learn about the raw materials used, the source of raw materials, processing parameters such as firing temperature or binders used in ceramic production. This information then can be used to explore the archaeometric background such as the nature and extent of cultural and technological interaction between different periods of history in Sri Lanka.

  8. ROLE OF X-RAY FLUORESCENCE IN A MODERN GEOCHEMICAL LABORATORY.

    USGS Publications Warehouse

    Taggart, Joseph E.

    1985-01-01

    Because modern geochemical laboratories can seldom have all new analytical equipment, it is clear that priorities must be assigned and choices made when selecting each new instrument. X-ray fluorescence (XRF) spectroscopy has come to play a vital role in this environment largely because it is a dependable, multielement, rapid method that covers a wide range of elemental concentrations, commonly with only one sample preparation. The following discussion centers on the role of modern XRF instrumentation in the resolution of geochemical problems. In order to present a comprehensive view of this role, this paper draws upon a great deal of information from numerous X-ray laboratories visited in the United States and Canada.

  9. Correlative VIS-fluorescence and soft X-ray cryo-microscopy/tomography of adherent cells.

    PubMed

    Hagen, Christoph; Guttmann, Peter; Klupp, Barbara; Werner, Stephan; Rehbein, Stefan; Mettenleiter, Thomas C; Schneider, Gerd; Grünewald, Kay

    2012-02-01

    Soft X-ray cryo-microscopy/tomography of vitreous samples is becoming a valuable tool in structural cell biology. Within the 'water-window' wavelength region (2.34-4.37nm), it provides absorption contrast images with high signal to noise ratio and resolution of a few tens of nanometer. Soft X-rays with wavelengths close to the K-absorption edge of oxygen penetrate biological samples with thicknesses in the micrometer range. Here, we report on the application of a recently established extension of the transmission soft X-ray cryo-microscope (HZB TXM) at the beamline U41-XM of the BESSY II electron storage ring by an in-column epi-fluorescence and reflected light cryo-microscope. We demonstrate the new capability for correlative fluorescence and soft X-ray cryo-microscopy/tomography of this instrument along a typical life science experimental approach - the correlation of a fluorophore-tagged protein (pUL34-GFP of pseudorabies virus, PrV, the nuclear membrane-anchored component of the nuclear egress complex of the Herpesviridae which interacts with viral pUL31) in PrV pUL34-GFP/pUL31 coexpressing mammalian cells, with virus-induced vesicular structures in the nucleus, expanding the nucleoplasmic reticulum. Taken together, our results demonstrate new possibilities to study the role of specific proteins in substructures of adherent cells, especially of the nucleus in toto, accessible to electron microscopy in thinned samples only. PMID:22210307

  10. Correlative VIS-fluorescence and soft X-ray cryo-microscopy/tomography of adherent cells

    PubMed Central

    Hagen, Christoph; Guttmann, Peter; Klupp, Barbara; Werner, Stephan; Rehbein, Stefan; Mettenleiter, Thomas C.; Schneider, Gerd; Grünewald, Kay

    2012-01-01

    Soft X-ray cryo-microscopy/tomography of vitreous samples is becoming a valuable tool in structural cell biology. Within the ‘water-window’ wavelength region (2.34–4.37 nm), it provides absorption contrast images with high signal to noise ratio and resolution of a few tens of nanometer. Soft X-rays with wavelengths close to the K-absorption edge of oxygen penetrate biological samples with thicknesses in the micrometer range. Here, we report on the application of a recently established extension of the transmission soft X-ray cryo-microscope (HZB TXM) at the beamline U41-XM of the BESSY II electron storage ring by an in-column epi-fluorescence and reflected light cryo-microscope. We demonstrate the new capability for correlative fluorescence and soft X-ray cryo-microscopy/tomography of this instrument along a typical life science experimental approach – the correlation of a fluorophore-tagged protein (pUL34-GFP of pseudorabies virus, PrV, the nuclear membrane-anchored component of the nuclear egress complex of the Herpesviridae which interacts with viral pUL31) in PrV pUL34-GFP/pUL31 coexpressing mammalian cells, with virus-induced vesicular structures in the nucleus, expanding the nucleoplasmic reticulum. Taken together, our results demonstrate new possibilities to study the role of specific proteins in substructures of adherent cells, especially of the nucleus in toto, accessible to electron microscopy in thinned samples only. PMID:22210307

  11. Experimental demonstration of novel imaging geometries for x-ray fluorescence computed tomography

    PubMed Central

    Fu, Geng; Meng, Ling-Jian; Eng, Peter; Newville, Matt; Vargas, Phillip; Riviere, Patrick La

    2013-01-01

    Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging imaging modality that maps the three-dimensional distribution of elements, generally metals, in ex vivo specimens and potentially in living animals and humans. At present, it is generally performed at synchrotrons, taking advantage of the high flux of monochromatic x rays, but recent work has demonstrated the feasibility of using laboratory-based x-ray tube sources. In this paper, the authors report the development and experimental implementation of two novel imaging geometries for mapping of trace metals in biological samples with ∼50–500 μm spatial resolution. Methods: One of the new imaging approaches involves illuminating and scanning a single slice of the object and imaging each slice's x-ray fluorescent emissions using a position-sensitive detector and a pinhole collimator. The other involves illuminating a single line through the object and imaging the emissions using a position-sensitive detector and a slit collimator. They have implemented both of these using synchrotron radiation at the Advanced Photon Source. Results: The authors show that it is possible to achieve 250 eV energy resolution using an electron multiplying CCD operating in a quasiphoton-counting mode. Doing so allowed them to generate elemental images using both of the novel geometries for imaging of phantoms and, for the second geometry, an osmium-stained zebrafish. Conclusions: The authors have demonstrated the feasibility of these two novel approaches to XFCT imaging. While they use synchrotron radiation in this demonstration, the geometries could readily be translated to laboratory systems based on tube sources. PMID:23718594

  12. Several approaches to the investigation of paintings with the use of portable X-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Trojek, T.; Trojková, D.

    2015-11-01

    This paper deals with several approaches to the application of X-ray fluorescence analysis and micro-analysis to non-destructive investigations of paintings. The methodology is described and demonstrated on a painting of known structure that was painted with modern artistic tempera paints. There is also a description and a demonstration of three depth profiling techniques that provide information on the depth distribution of elements in the surface layers of a painting. The three techniques utilize (a) the internal X-ray ratios of the elements that are present, (b) X-ray fluorescence analysis with two detectors with different angles of detection of characteristic X-rays, and (c) a technique based on comparing X-ray spectra measured with a tilted sample. The capabilities and demands on instrumentation and interpretation of the results are compared for all these techniques.

  13. Simultaneous measurements of X-ray reflectivity and grazing incidence fluorescence at BL-16 beamline of Indus-2

    SciTech Connect

    Das, Gangadhar; Kane, S. R.; Khooha, Ajay; Singh, A. K.; Tiwari, M. K.

    2015-05-15

    A new multipurpose x-ray reflectometer station has been developed and augmented at the microfocus beamline (BL-16) of Indus-2 synchrotron radiation source to facilitate synchronous measurements of specular x-ray reflectivity and grazing incidence x-ray fluorescence emission from thin layered structures. The design and various salient features of the x-ray reflectometer are discussed. The performance of the reflectometer has been evaluated by analyzing several thin layered structures having different surface interface properties. The results reveal in-depth information for precise determination of surface and interface properties of thin layered materials demonstrating the immense potential of the combined measurements of x-ray reflectivity and grazing incidence fluorescence on a single reflectometer.

  14. Advanced combined application of micro-X-ray diffraction/micro-X-ray fluorescence with conventional techniques for the identification of pictorial materials from Baroque Andalusia paintings.

    PubMed

    Herrera, L K; Montalbani, S; Chiavari, G; Cotte, M; Solé, V A; Bueno, J; Duran, A; Justo, A; Perez-Rodriguez, J L

    2009-11-15

    The process of investigating paintings includes the identification of materials to solve technical and historical art questions, to aid in the deduction of the original appearance, and in the establishment of the chemical and physical conditions for adequate restoration and conservation. In particular, we have focused on the identification of several samples taken from six famous canvases painted by Pedro Atanasio Bocanegra, who created a very special collection depicting the life of San Ignacio, which is located in the church of San Justo y Pastor of Granada, Spain. The characterization of the inorganic and organic compounds of the textiles, preparation layers, and pictorial layers have been carried out using an XRD diffractometer, SEM observations, EDX spectrometry, FT-IR spectrometry (both in reflection and transmission mode), pyrolysis/gas chromatography/mass spectrometry and synchrotron-based micro-X-ray techniques. In this work, the advantages over conventional X-ray diffraction of using combined synchrotron-based micro-X-ray diffraction and micro-X-ray fluorescence in the identification of multi-layer paintings is demonstrated. PMID:19782194

  15. Airborne particulate matter (PM) filter analysis and modeling by total reflection X-ray fluorescence (TXRF) and X-ray standing wave (XSW).

    PubMed

    Borgese, L; Salmistraro, M; Gianoncelli, A; Zacco, A; Lucchini, R; Zimmerman, N; Pisani, L; Siviero, G; Depero, L E; Bontempi, E

    2012-01-30

    This work is presented as an improvement of a recently introduced method for airborne particulate matter (PM) filter analysis [1]. X-ray standing wave (XSW) and total reflection X-ray fluorescence (TXRF) were performed with a new dedicated laboratory instrumentation. The main advantage of performing both XSW and TXRF, is the possibility to distinguish the nature of the sample: if it is a small droplet dry residue, a thin film like or a bulk sample. Another advantage is related to the possibility to select the angle of total reflection to make TXRF measurements. Finally, the possibility to switch the X-ray source allows to measure with more accuracy lighter and heavier elements (with a change in X-ray anode, for example from Mo to Cu). The aim of the present study is to lay the theoretical foundation of the new proposed method for airborne PM filters quantitative analysis improving the accuracy and efficiency of quantification by means of an external standard. The theoretical model presented and discussed demonstrated that airborne PM filters can be considered as thin layers. A set of reference samples is prepared in laboratory and used to obtain a calibration curve. Our results demonstrate that the proposed method for quantitative analysis of air PM filters is affordable and reliable without the necessity to digest filters to obtain quantitative chemical analysis, and that the use of XSW improve the accuracy of TXRF analysis.

  16. Airborne Particulate Matter (PM) filter analysis and modeling by Total reflection X-Ray Fluorescence (TXRF) and X-Ray Standing Wave (XSW)

    PubMed Central

    Borgese, L.; Salmistraro, M.; Gianoncelli, A; Zacco, A.; Lucchini, R.; Zimmerman, N.; Pisani, L.; Siviero, G.; Depero, L. E.; Bontempi, E.

    2011-01-01

    This work is presented as an improvement of a recently introduced method for airborne particulate matter (PM) filter analysis [1]. X-ray Standing Wave (XSW) and Total reflection X-Ray Fluorescence (TXRF) were performed with a new dedicated laboratory instrumentation. The main advantage of performing both XSW and TXRF, is the possibility to distinguish the nature of the sample: if it is a small droplet dry residue, a thin film like or a bulk sample; and to select the angle of total reflection to make TXRF measurements. Finally, the possibility to switch the X-ray source allows to measure with more accuracy lighter and heavier elements (with a a change in X-ray anode, for example from Mo to Cu). The aim of the present study is to lay the theoretical foundation of the new proposed method for airborne PM filters quantitative analysis improving the accuracy and efficiency of quantification by means of an external standard. The theoretical model presented and discussed demonstrated that airborne PM filters can be considered as thin layers. A set of reference samples is prepared in laboratory and used to obtain a calibration curve. Our results demonstrate that the proposed method for quantitative analysis of air PM filters is affordable and reliable without the necessity to digest filters to obtain quantitative chemical analysis, and that the use of XRW improve the accuracy of TXRF analysis. PMID:22284465

  17. Identification of lead and other elements in ceramic glazes and housewares by 109Cd-induced X-ray fluorescence emission spectrometry.

    PubMed

    Anderson, D L; Cunningham, W C; Lindstrom, T R; Olmez, I

    1995-01-01

    Radioisotope x-ray fluorescence spectrometry was investigated as a potential screening method for Pb and other elements in housewares. Thirty-six commercial houseware items and 87 ceramic test tiles (85 fired with hobby glazes and 2 blank bisques) were examined qualitatively for the presence of Pb by using 109Cd-induced L x-ray fluorescence emission spectrometry. For the housewares, the technique provided fast, nondestructive analysis of areas with about 10 cm diameters (general regions) to about 4 mm diameters (isolated design regions). Pb was found in 25 of 28 ceramicware items, in all 8 other housewares, and in all the test-tile glazes above the limit of detection of 1 count per second (cps) for Pb L beta x-rays. For housewares, Pb identification did not always correspond to Pb leachability. For 68 test-tile glazes labeled as containing Pb (39 of which were also labeled 'dinnerware safe' or 'safe for food containers'), count rates ranged from 290 to 730 cps, whereas for the other 17 glazes labeled (with one exception) 'non-toxic,' much lower count rates (5-61 cps) were obtained. Other elements found in the housewares or test glazes were As, Au, Ca, Co, Cr, Cu, Fe, Mn, Nb, Ni, Rb, Sr, Y, Zn, and Zr.

  18. Analysis of nuclear materials by energy dispersive x-ray fluorescence and spectral effects of alpha decay

    SciTech Connect

    Worley, Christopher G

    2009-01-01

    Energy dispersive X-ray fluorescence (EDXRF) spectra collected from alpha emitters are complicated by artifacts inherent to the alpha decay process, particularly when using portable instruments. For example, {sup 239}Pu EDXRF spectra exhibit a prominent uranium L X-ray emission peak series due to sample alpha decay rather than source-induced X-ray fluorescence. A portable EDXRF instrument was used to collect spectra from plutonium, americium, and a Pu-contaminated steel sample. The plutonium sample was also analyzed by wavelength dispersive XRF to demonstrate spectral differences observed when using these very different instruments.

  19. Proton induced monochromatic X-rays: A technique for solving interference problems in X-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Karydas, A. G.; Paradellis, T.

    1999-06-01

    With PIXE and EDXRF techniques excellent sensitivities for most of the elements in a wide range of matrix sample compositions can be obtained. Despite this, in some cases, strong interferences originating from the presence in the matrix of an element with high concentration, can limit these sensitivities considerably. A combination of the above techniques, PIXE and XRF, seems to be the most efficient solution to this problem. By choosing the primary target properly, protons can produce an intense, almost monoenergetic exciting X-ray radiation, which in several cases selectively excites the elements of interest in the sample and overcomes the production of X-rays of the element dominating the matrix. The application of this technique to specific interference problems, either in the characterization of thin films deposited onto various substrates (YBaCuO film onto LaAlO3 crystal and a MgF2 film onto a SiO2 matrix) or in the determination of trace elements in a high Z thick matrix (copper) is discussed.

  20. Development of Ta-based Superconducting Tunnel Junction X-ray Detectors for Fluorescence XAS

    SciTech Connect

    Friedrich, S; Drury, O; Hall, J; Cantor, R

    2009-09-23

    We are developing superconducting tunnel junction (STJ) soft X-ray detectors for chemical analysis of dilute samples by fluorescence-detected X-ray absorption spectroscopy (XAS). Our 36-pixel Nb-based STJ spectrometer covers a solid angle {Omega}/4{pi} {approx} 10{sup -3}, offers an energy resolution of {approx}10-20 eV FWHM for energies up to {approx}1 keV, and can be operated at total count rates of {approx}10{sup 6} counts/s. For increased quantum efficiency and cleaner response function, we have now started the development of Ta-based STJ detector arrays. Initial devices modeled after our Nb-based STJs have an energy resolution below 10 eV FWHM for X-ray energies below 1 keV, and pulse rise time discrimination can be used to improve their response function for energies up to several keV. We discuss the performance of the Ta-STJs and outline steps towards the next-generation of large STJ detector arrays with higher sensitivity.

  1. Wavelength dispersive X-ray fluorescence imaging using a high-sensitivity imaging sensor

    NASA Astrophysics Data System (ADS)

    Ohmori, Takashi; Kato, Shuichi; Doi, Makoto; Shoji, Takashi; Tsuji, Kouichi

    2013-05-01

    A new wavelength-dispersive X-ray fluorescence (WD-XRF) imaging spectrometer equipped with a high-sensitivity imaging sensor was developed in our laboratory. In this instrument, a straight polycapillary optic was applied instead of a Soller slit as well as a 2D imaging X-ray detector instead of X-ray counters, which are used in conventional WD-XRF spectrometers. Therefore, images of elemental distribution were available after a short exposure time. Ni Kα images and Cu Kα images were clearly obtained at corresponding diffraction angles for a short exposure time of 10 s. By optimizing the spectrometer, the time required for imaging is reduced, leading to XRF image movies. It is difficult to distinguish two peaks (Ti Kα (4.508 keV) and Ba Lα (4.465 keV)) due to the poor energy resolution of EDXRS. However, Ti and Ba images could be successfully observed by the WD-XRF imaging spectrometer. The energy resolution of the developed spectrometer was 25 eV at the Ti Kα peak.

  2. Phase-resolved x-ray ferromagnetic resonance measurements in fluorescence yield

    SciTech Connect

    Marcham, M. K.; Keatley, P. S.; Neudert, A.; Hicken, R. J.; Cavill, S. A.; Shelford, L. R.; van der Laan, G.; Telling, N. D.; Childress, J. R.; Katine, J. A.; Shafer, P.; Arenholz, E.

    2010-10-14

    Phase-resolved x-ray ferromagnetic resonance (XFMR) has been measured in fluorescence yield, extending the application of XFMR to opaque samples on opaque substrates. Magnetization dynamics were excited in a Co{sub 50}Fe{sub 50}(0.7)/Ni{sub 90}Fe{sub 10}(5) bilayer by means of a continuous wave microwave excitation, while x-ray magnetic circular dichroism (XMCD) spectra were measured stroboscopically at different points in the precession cycle. By tuning the x-ray energy to the L{sub 3} edges of Ni and Fe, the dependence of the real and imaginary components of the element specific magnetic susceptibility on the strength of an externally applied static bias field was determined. First results from measurements on a Co{sub 50}Fe{sub 50}(0.7)/Ni{sub 90}Fe{sub 10}(5)/Dy(1) sample confirm that enhanced damping results from the addition of the Dy cap.

  3. Development of Ta-based Superconducting Tunnel Junction X-ray Detectors for Fluorescence XAS

    SciTech Connect

    Friedrich, Stephan; Drury, Owen B.; Hall, John; Cantor, Robin

    2010-06-23

    We are developing superconducting tunnel junction (STJ) soft X-ray detectors for chemical analysis of dilute samples by fluorescence-detected X-ray absorption spectroscopy (XAS). Our 36-pixel Nb-based STJ spectrometer covers a solid angle {Omega}/4{pi}{approx_equal}10{sup -3}, offers an energy resolution of {approx}10-20 eV FWHM for energies up to {approx}1 keV, and can be operated at total count rates of {approx}10{sup 6} counts/s. For increased quantum efficiency and cleaner response function, we have now started the development of Ta-based STJ detector arrays. Initial devices modeled after our Nb-based STJs have an energy resolution below 10 eV FWHM for X-ray energies below 1 keV, and pulse rise time discrimination can be used to improve their response function for energies up to several keV. We discuss the performance of the Ta-STJs and outline steps towards the next-generation of large STJ detector arrays with higher sensitivity.

  4. Proton-induces and x-ray induced fluorescence analysis of scoliotic tissue

    SciTech Connect

    Panessa-Warren, B J; Kraner, H W; Jones, K W; Weiss, L S

    1980-02-01

    Adolescent idiopathic scoliosis is characterized by a curvature or assymetry of the spine which may become progressively more severe, with clinical symptoms appearing just prior to, or during, puberty. The incidence for scoliosis in the age group from 12 to 14 years of age has been reported as high as 8 to 10%, with more than 80% of the cases occurring in females. Although pathologic changes exist in muscles from both sides of the spinal curvature, and no statistically significant side differences have been reported, morphologic changes suggest that the concanve side is the most affected. This paper reports our preliminary data on the elemental composition of individual muscle fibers derived from convex, concave and gluteal scoliotic muscle, and erythrocytes from scoliotic and normal patients, analyzed by proton induced x-ray emission (PIXE) and x-ray fluorescence spectroscopy (XRF). A new type of specimen holder was designed for this study which offers low x-ray background, minimal absorption and maintenance of a moist environment around the specimen.

  5. Fast X-Ray Fluorescence Camera Combined with Wide Band Pass Monochromatic Synchrotron Beam

    NASA Astrophysics Data System (ADS)

    Sakurai, Kenji; Mizusawa, Mari

    2004-05-01

    A double W/B4C multilayer monochromator (2d=50.4Å) was commissioned for non-scanning X-ray fluorescence (XRF) imaging experiments. The combination of a brilliant multi-pole wiggler source and the present wide band pass monochromator permits 1.2 × 1013 photons/sec at the sample position for 8.04 keV X-rays. Energy resolution ΔE and ΔE/E are 300˜500 eV and ˜5%, respectively. The exit beam height is constant for X-ray energy ranging from 5.5 to 13.0 keV. Indirect cooling of the 1st multilayer works successfully. In addition, a new fast CCD camera was developed for quick readout and transfer of the image data. It was found that the typical exposure time for one XRF image with 1000 × 1000 pixels is 0.03˜1 sec. This permits in-situ movie recording for the distribution of elements.

  6. X-ray fluorescence measurements of the surface elemental composition of asteroid 433 Eros

    NASA Astrophysics Data System (ADS)

    Nittler, L. R.; Starr, R. D.; Lim, L.; McCoy, T. J.; Burbine, T. H.; Reedy, R. C.; Trombka, J. I.; Gorenstein, P.; Squyres, S. W.; Boynton, W. V.; McClanahan, T. P.; Bhangoo, J. S.; Clark, P. E.; Murphy, M. E.; Killen, R.

    2001-12-01

    We report major element ratios determined for the S-class asteroid 433 Eros using remote-sensing x-ray fluorescence spectroscopy with the near-Earth asteroid rendezvous Shoemaker x-ray spectrometer (XRS). Data analysis techniques and systematic errors are described in detail. Data acquired during five solar flares and during two extended "quiet Sun" periods are presented; these results sample a representative portion of the asteroid's surface. Although systematic uncertainties are potentially large, the most internally consistent and plausible interpretation of the data is that Eros has primitive Mg/Si, Al/Si, Ca/Si and Fe/Si ratios, closely similar to H or R chondrites. Global differentiation of the asteroid is ruled out. The S/Si ratio is much lower than that of chondrites, probably reflecting impact-induced volatilization and/or photo- or ion-induced sputtering of sulfur at the surface of the asteroid. An alternative explanation for the low S/Si ratio is that it reflects a limited degree of melting with loss of an FeS-rich partial melt. Size-sorting processes could lead to segregation of Fe-Ni metal from silicates within the regolith of Eros; this could indicate that the Fe/Si ratios determined by the x-ray spectrometer are not representative of the bulk Eros composition.

  7. Multilayers quantitative X-ray fluorescence analysis applied to easel paintings.

    PubMed

    de Viguerie, Laurence; Sole, V Armando; Walter, Philippe

    2009-12-01

    X-ray fluorescence spectrometry (XRF) allows a rapid and simple determination of the elemental composition of a material. As a non-destructive tool, it has been extensively used for analysis in art and archaeology since the early 1970s. Whereas it is commonly used for qualitative analysis, recent efforts have been made to develop quantitative treatment even with portable systems. However, the interpretation of the results obtained with this technique can turn out to be problematic in the case of layered structures such as easel paintings. The use of differential X-ray attenuation enables modelling of the various layers: indeed, the absorption of X-rays through different layers will result in modification of intensity ratio between the different characteristic lines. This work focuses on the possibility to use XRF with the fundamental parameters method to reconstruct the composition and thickness of the layers. This method was tested on several multilayers standards and gives a maximum error of 15% for thicknesses and errors of 10% for concentrations. On a painting test sample that was rather inhomogeneous, the XRF analysis provides an average value. This method was applied in situ to estimate the thickness of the layers a painting from Marco d'Oggiono, pupil of Leonardo da Vinci.

  8. New Homogeneous Standards by Atomic Layer Deposition for Synchrotron X-ray Fluorescence and Absorption Spectroscopies.

    SciTech Connect

    Butterworth, A.L.; Becker, N.; Gainsforth, Z.; Lanzirotti, A.; Newville, M.; Proslier, T.; Stodolna, J.; Sutton, S.; Tyliszczak, T.; Westphal, A.J.; Zasadzinski, J.

    2012-03-13

    Quantification of synchrotron XRF analyses is typically done through comparisons with measurements on the NIST SRM 1832/1833 thin film standards. Unfortunately, these standards are inhomogeneous on small scales at the tens of percent level. We are synthesizing new homogeneous multilayer standards using the Atomic Layer Deposition technique and characterizing them using multiple analytical methods, including ellipsometry, Rutherford Back Scattering at Evans Analytical, Synchrotron X-ray Fluorescence (SXRF) at Advanced Photon Source (APS) Beamline 13-ID, Synchrotron X-ray Absorption Spectroscopy (XAS) at Advanced Light Source (ALS) Beamlines 11.0.2 and 5.3.2.1 and by electron microscopy techniques. Our motivation for developing much-needed cross-calibration of synchrotron techniques is borne from coordinated analyses of particles captured in the aerogel of the NASA Stardust Interstellar Dust Collector (SIDC). The Stardust Interstellar Dust Preliminary Examination (ISPE) team have characterized three sub-nanogram, {approx}1{micro}m-sized fragments considered as candidates to be the first contemporary interstellar dust ever collected, based on their chemistries and trajectories. The candidates were analyzed in small wedges of aerogel in which they were extracted from the larger collector, using high sensitivity, high spatial resolution >3 keV synchrotron x-ray fluorescence spectroscopy (SXRF) and <2 keV synchrotron x-ray transmission microscopy (STXM) during Stardust ISPE. The ISPE synchrotron techniques have complementary capabilities. Hard X-ray SXRF is sensitive to sub-fg mass of elements Z {ge} 20 (calcium) and has a spatial resolution as low as 90nm. X-ray Diffraction data were collected simultaneously with SXRF data. Soft X-ray STXM at ALS beamline 11.0.2 can detect fg-mass of most elements, including cosmochemically important oxygen, magnesium, aluminum and silicon, which are invisible to SXRF in this application. ALS beamline 11.0.2 has spatial resolution

  9. Tracing Ambient Air Geochemistry using a Modified X-Ray Fluorescence Filter Method

    NASA Astrophysics Data System (ADS)

    Steiner, J. C.; Rudolph, E.; Wrice, T.

    2002-12-01

    Modifications of x-ray fluorescence counting procedures enable tracing of aerosol dispersals related to weather fronts and local weather phenomena. Improved X-ray fluorescence methods for bulk aerosols deposited under positive air pressure conditions onto Millipore filters at 80 liters/hour enable the tracing of geological samples in periods down to one hour. Vacuum-plating aliquots of USGS standards onto 0.2 micron polycarbonate and quartz Millipore filters create standards with a shelf life of several months. The analytical system permits detection of light oxides, such as silica to 10 ppm, and heavy elements, such as iron to 0.5 ppm. These collections allow discriminations to be drawn between dominantly geological, silica-enriched air mass and dominantly iron-enriched air of possible industrial origin. These ambient air collections at 120 feet elevation at City College are used to create possible distinctions in air masses related to points of origin. Splits of aerosol examined by neutron activation and coupled plasma emission spectroscopy agree with x-ray fluorescence methods to within analytical error. Aerosol flux conditions are monitored for speciation using direct examination by scanning electron microscopy with energy dispersive analytical capability plus aerosol physical properties by sun photometry. The latter provides bulk optical transmission at six major wavelengths and estimates for bulk aerosol size properties. Preliminary data show positive photometry links with iron-aerosols with a correlation coefficient with southwesterly wind-driven conditions of seventy percent over a four hour monitoring period. Aerosol flux comparisons with heavy metal populations, Ba, Rb, Zr, La show uniform distributions with iron- and silica-enriched populations indicating a pervasive background condition in the ambient air mass over New York City.

  10. Non-destructive in situ study of "Mad Meg" by Pieter Bruegel the Elder using mobile X-ray fluorescence, X-ray diffraction and Raman spectrometers

    NASA Astrophysics Data System (ADS)

    Van de Voorde, Lien; Van Pevenage, Jolien; De Langhe, Kaat; De Wolf, Robin; Vekemans, Bart; Vincze, Laszlo; Vandenabeele, Peter; Martens, Maximiliaan P. J.

    2014-07-01

    "Mad Meg", a figure of Flemish folklore, is the subject of a famous oil-on-panel painting by the Flemish renaissance artist Pieter Bruegel the Elder, exhibited in the Museum Mayer van den Bergh (Antwerp, Belgium). This article reports on the in situ chemical characterization of this masterpiece by using currently available state-of-the-art portable analytical instruments. The applied non-destructive analytical approach involved the use of a) handheld X-ray fluorescence instrumentation for retrieving elemental information and b) portable X-ray fluorescence/X-ray diffraction instrumentation and laser-based Raman spectrometers for obtaining structural/molecular information. Next to material characterization of the used pigments and of the different preparation layers of the painting, also the verification of two important historical iconographic hypotheses is performed concerning the economic way of painting by Brueghel, and whether or not he used blue smalt pigment for painting the boat that appears towards the top of the painting. The pigments identified are smalt pigment (65% SiO2 + 15% K2O + 10% CoO + 5% Al2O3) for the blue color present in all blue areas of the painting, probably copper resinate for the green colors, vermillion (HgS) as red pigment and lead white is used to form different colors. The comparison of blue pigments used on different areas of the painting gives no differences in the elemental fingerprint which confirms the existing hypothesis concerning the economic painting method by Bruegel.

  11. Hyper-filter-fluorescer spectrometer for x-rays above 120 keV

    DOEpatents

    Wang, Ching L.

    1983-01-01

    An apparatus utilizing filter-fluorescer combinations is provided to measure short bursts of high fluence x-rays above 120 keV energy, where there are no practical absorption edges available for conventional filter-fluorescer techniques. The absorption edge of the prefilter is chosen to be less than that of the fluorescer, i.e., E.sub.PRF E.sub.F. In this way, the response function is virtually zero between E.sub.PRF and E.sub.F and well defined and enhanced in an energy band of less than 1000 keV above the 120 keV energy.

  12. Imaging x-ray fluorescence relevant to hydrodynamic mixing experiments at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    MacDonald, Michael; Gamboa, Eliseo; Kuranz, Carolyn; Keiter, Paul; Drake, R. Paul

    2012-10-01

    The National Ignition Facility (NIF) is capable of providing enough energy to explore areas of physics that are not possible on any previous laser system. This includes large-volume, geometrically complex hydrodynamic and radiation hydrodynamic experiments in which traditional, line-integrated radiographic techniques limit the quality of the results. As an example, we are involved in divergent hydrodynamic experiments at the NIF, motivated by supernova hydrodynamics, that cannot be diagnosed in detail with transmission radiography. X-ray scattering has been considered for this purpose and appears feasible [1]. Here we consider fluorescence imaging, a better candidate as the cross section of photoabsorption in the several-keV range is roughly 100 times larger than that of scattering. A single layer of the target will be uniformly doped with a fluorescent tracer, which will be pumped by a sheet of x-rays. The fluorescent intensity will be measured to create a density map of the doped material as it mixes with other layers. Developing this diagnostic will create a powerful tool to characterize hydrodynamic experiments with complex geometries.[4pt] [1] Huntington et al. High Energy Density Physics 6, 194 (2010).

  13. On the emitting region of X-ray fluorescent lines around Compton-thick AGN

    NASA Astrophysics Data System (ADS)

    Liu, Jiren

    2016-06-01

    X-ray fluorescent lines are unique features of the reflection spectrum of the torus when irradiated by the central active galactic nuclei (AGN). Their intrinsic line width can be used to probe the line-emitting region. Previous studies have focused on the Fe K α line at 6.4 keV, which is the most prominent fluorescent line. These studies, however, are limited by the spectral resolution of currently available instruments, the best of which is ˜1860 km s-1 afforded by the Chandra High-Energy Grating (HEG). The HEG spectral resolution is improved by a factor of 4 at 1.74 keV, where the Si K α line is located. We measured the full width at half-maximum of the Si K α line for Circinus, Mrk 3, and NGC 1068, which are 570 ± 240, 730 ± 320, and 320 ± 280 km s-1, respectively. They are 3-5 times smaller than those measured with the Fe K α line previously. It shows that the intrinsic widths of the Fe K α line are most likely to be overestimated. The measured widths of the Si K α line put the line-emitting region outside the dust sublimation radius in these galaxies. It indicates that for Compton-thick AGN, the X-ray fluorescence material are likely to be the same as the dusty torus emitting in the infrared band.

  14. Background estimation methods for quantitative x-ray fluorescence analysis of gold nanoparticles in biomedical applications

    NASA Astrophysics Data System (ADS)

    Ren, Liqiang; Wu, Di; Li, Yuhua; Chen, Wei R.; Liu, Hong

    2014-02-01

    Accurate background estimation to isolate the fluorescence signals is an important issue for quantitative X-ray fluorescence (XRF) analysis of gold nanoparticles (GNPs). Though a good estimation can be obtained experimentally through acquiring the background spectrum of water solution, it inevitably leads to unnecessary second exposure in reality. Thus, several numerical methods such as trapezoidal shape estimation, interpolation by polynomial fitting and SNIP (Statistics sensitive Nonlinear Iterative Peak-Clipping) algorithm are proposed to achieve this goal. This paper aims to evaluate the estimation results calculated by these numerical methods through comparing with that acquired using the experimental way, in term of mean squared error (MSE). Four GNP/water solutions with various concentrations from 0.0% to 1.0% by weight are prepared. Then, ten spectra are acquired for each solution for further analysis, under the identical condition of using pencil beam x-ray and single spectrometer. Finally, the experimental and numerical methods are performed on these spectra within the optimally determined energy window and their statistical characteristics are analyzed and compared. These numerical background estimation methods as well as the evaluation methods can be easily extended to analyze the fluorescence signals of other nanoparticle biomarkers such as gadolinium, platinum and Barium in multiple biomedical applications.

  15. The Bionanoprobe: hard X-ray fluorescence nanoprobe with cryogenic capabilities.

    PubMed

    Chen, S; Deng, J; Yuan, Y; Flachenecker, C; Mak, R; Hornberger, B; Jin, Q; Shu, D; Lai, B; Maser, J; Roehrig, C; Paunesku, T; Gleber, S C; Vine, D J; Finney, L; VonOsinski, J; Bolbat, M; Spink, I; Chen, Z; Steele, J; Trapp, D; Irwin, J; Feser, M; Snyder, E; Brister, K; Jacobsen, C; Woloschak, G; Vogt, S

    2014-01-01

    Hard X-ray fluorescence microscopy is one of the most sensitive techniques for performing trace elemental analysis of biological samples such as whole cells and tissues. Conventional sample preparation methods usually involve dehydration, which removes cellular water and may consequently cause structural collapse, or invasive processes such as embedding. Radiation-induced artifacts may also become an issue, particularly as the spatial resolution increases beyond the sub-micrometer scale. To allow imaging under hydrated conditions, close to the `natural state', as well as to reduce structural radiation damage, the Bionanoprobe (BNP) has been developed, a hard X-ray fluorescence nanoprobe with cryogenic sample environment and cryo transfer capabilities, dedicated to studying trace elements in frozen-hydrated biological systems. The BNP is installed at an undulator beamline at sector 21 of the Advanced Photon Source. It provides a spatial resolution of 30 nm for two-dimensional fluorescence imaging. In this first demonstration the instrument design and motion control principles are described, the instrument performance is quantified, and the first results obtained with the BNP on frozen-hydrated whole cells are reported.

  16. The Bionanoprobe: hard X-ray fluorescence nanoprobe with cryogenic capabilities

    PubMed Central

    Chen, S.; Deng, J.; Yuan, Y.; Flachenecker, C.; Mak, R.; Hornberger, B.; Jin, Q.; Shu, D.; Lai, B.; Maser, J.; Roehrig, C.; Paunesku, T.; Gleber, S. C.; Vine, D. J.; Finney, L.; VonOsinski, J.; Bolbat, M.; Spink, I.; Chen, Z.; Steele, J.; Trapp, D.; Irwin, J.; Feser, M.; Snyder, E.; Brister, K.; Jacobsen, C.; Woloschak, G.; Vogt, S.

    2014-01-01

    Hard X-ray fluorescence microscopy is one of the most sensitive techniques for performing trace elemental analysis of biological samples such as whole cells and tissues. Conventional sample preparation methods usually involve dehydration, which removes cellular water and may consequently cause structural collapse, or invasive processes such as embedding. Radiation-induced artifacts may also become an issue, particularly as the spatial resolution increases beyond the sub-micrometer scale. To allow imaging under hydrated conditions, close to the ‘natural state’, as well as to reduce structural radiation damage, the Bionanoprobe (BNP) has been developed, a hard X-ray fluorescence nanoprobe with cryogenic sample environment and cryo transfer capabilities, dedicated to studying trace elements in frozen-hydrated biological systems. The BNP is installed at an undulator beamline at sector 21 of the Advanced Photon Source. It provides a spatial resolution of 30 nm for two-dimensional fluorescence imaging. In this first demonstration the instrument design and motion control principles are described, the instrument performance is quantified, and the first results obtained with the BNP on frozen-hydrated whole cells are reported. PMID:24365918

  17. Application of grazing incidence x-ray fluorescence technique to discriminate and quantify implanted solar wind

    SciTech Connect

    Kitts, K.; Choi, Y.; Eng, P. J.; Ghose, S. K.; Sutton, S. R.; Rout, B.

    2009-03-15

    NASA launched the Genesis return mission to obtain pristine solar wind samples in order to better understand solar wind mechanics, solar physics, and solar system evolution. Unfortunately, the probe crash-landed shattering the collector plates necessitating the application of a grazing incidence x-ray fluorescence technique. This nondestructive methodology differentiates the terrestrial contamination from the low concentration implanted solar wind. Using this technique, the elemental depth distribution is obtained resulting in the determination of absolute solar wind elemental abundance. We describe this application and present the solar wind Fe concentration determination as an example.

  18. X-ray fluorescence analysis of archaeological finds and art objects: recognizing gold and gilding.

    PubMed

    Trojek, Tomáš; Hložek, Martin

    2012-07-01

    Many cultural heritage objects were gilded in the past, and nowadays they can be found in archeological excavations or in historical buildings dating back to the Middle Ages, or from the modern period. Old gilded artifacts have been studied using X-ray fluorescence analysis and 2D microanalysis. Several techniques that enable the user to distinguish gold and gilded objects are described and then applied to investigate artifacts. These techniques differ in instrumentation, data analysis and numbers of measurements. The application of Monte Carlo calculation to a quantitative analysis of gilded objects is also introduced.

  19. Preliminary testing of a prototype portable X-ray fluorescence spectrometer

    NASA Astrophysics Data System (ADS)

    Patten, L. L.; Anderson, N. B.; Stevenson, J. J.

    1982-08-01

    A portable X-ray fluorescence spectrometer for use as an analyzer in mineral resource investigative work was built and tested. The prototype battery powered spectrometer, measuring 11 by 12 by 5 inches and weighing only about 15 pounds, was designed specifically for field use. The spectrometer has two gas proportional counters and two radioactive sources, Cd (10a) and Fe (55). Preliminary field and laboratory tests on rock specimens and rock pulps have demonstrated the capability of the spectrometer to detect 33 elements to date. Characteristics of the system present some limitations, however, and further improvements are recommended.

  20. Preliminary testing of a prototype portable X-ray fluorescence spectrometer

    NASA Technical Reports Server (NTRS)

    Patten, L. L.; Anderson, N. B.; Stevenson, J. J.

    1982-01-01

    A portable X-ray fluorescence spectrometer for use as an analyzer in mineral resource investigative work was built and tested. The prototype battery powered spectrometer, measuring 11 by 12 by 5 inches and weighing only about 15 pounds, was designed specifically for field use. The spectrometer has two gas proportional counters and two radioactive sources, Cd (10a) and Fe (55). Preliminary field and laboratory tests on rock specimens and rock pulps have demonstrated the capability of the spectrometer to detect 33 elements to date. Characteristics of the system present some limitations, however, and further improvements are recommended.

  1. Combined backscatter Moessbauer spectrometer/x ray fluorescence analyzer (BaMS/XRF) for extraterrestrial surfaces

    NASA Technical Reports Server (NTRS)

    Shelfer, T. D.; Wills, E. L.; Agresti, D. G.; Pimperl, M. M.; Shen, M. H.; Morris, R. V.; Nguyen, T.

    1993-01-01

    We have designed and tested a prototype combined backscatter Moessbauer spectrometer and x-ray fluorescence analyzer (BaMS/XRF). A space qualified instrument based on this design would be suitable for in-situ use on planetary missions to the surfaces of the Moon (Artemis and lunar outpost), Mars (MESUR), asteroids, or other solid solar system objects. The BaMS/XRF instrument is designed to be capable of concurrent sample analyses for the mineralogy of iron-bearing phases and elemental composition without the need for sample preparation.

  2. Analysis Results for Lunar Soil Simulant Using a Portable X-Ray Fluorescence Analyzer

    NASA Technical Reports Server (NTRS)

    Boothe, R. E.

    2006-01-01

    Lunar soil will potentially be used for oxygen generation, water generation, and as filler for building blocks during habitation missions on the Moon. NASA s in situ fabrication and repair program is evaluating portable technologies that can assess the chemistry of lunar soil and lunar soil simulants. This Technical Memorandum summarizes the results of the JSC 1 lunar soil simulant analysis using the TRACeR III IV handheld x-ray fluorescence analyzer, manufactured by KeyMaster Technologies, Inc. The focus of the evaluation was to determine how well the current instrument configuration would detect and quantify the components of JSC-1.

  3. Analyses of lake sediments from Itaipú dam using x-ray fluorescence

    NASA Astrophysics Data System (ADS)

    dos Santos, Felipe Rodrigues; Novacoski, Ezequiel J.; Melquiades, Fábio L.

    2013-05-01

    The objective of this study was to use principal component analysis (PCA), with data from Energy Dispersive X-Ray Fluorescence (EDXRF) of sediment samples from Itaipú artificial beaches, to find correlations between metal concentrations present in the sediments and physical-chemical properties. Samples were collected at nine points at Itaipu dam lake dam from 80 cm depth of water column, dried at room temperature and grinded in a mortar to obtain a particle size lower than 70 μm. The samples with higher concentration of organic matter and metal ions have correlation with the smaller sample size, i.e., clay.

  4. In-Situ Silver Acetylide Silver Nitrate Explosive Deposition Measurements Using X-Ray Fluorescence.

    SciTech Connect

    Covert, Timothy Todd

    2014-09-01

    The Light Initiated High Explosive facility utilized a spray deposited coating of silver acetylide - silver nitrate explosive to impart a mechanical shock into targets of interest. A diagnostic was required to measure the explosive deposition in - situ. An X - ray fluorescence spectrometer was deployed at the facility. A measurement methodology was developed to measure the explosive quantity with sufficient accuracy. Through the use of a tin reference material under the silver based explosive, a field calibration relationship has been developed with a standard deviation of 3.2 % . The effect of the inserted tin material into the experiment configuration has been explored.

  5. Waste reduction and process improvements in the analysis of plutonium by x-ray fluorescence

    SciTech Connect

    Worley, Christopher G; Sodweberg, Constance B; Townsend, Lisa E

    2009-01-01

    Significant modifications were made to a sample preparation process for quantifying gallium in plutonium metal by wavelength dispersive X-ray fluorescence. These changes were made to minimize waste and improve process safety and efficiency. Sample sizes were reduced, cheaper sample preparation acids were used, and safety improvements were implemented. Using this modified process, results from analyzing a batch oftest samples indicated that relative precision and accuracy were {approx}0.2% and {approx}0.1% respectively, which is comparable to that obtained using the older, established sample preparation method.

  6. Use of X-ray Fluorescence Analysis for the Determination of Rare Earth Elements

    NASA Astrophysics Data System (ADS)

    Schramm, Rainer

    2016-09-01

    X-ray fluorescence spectrometry (XRF) is a powerful tool for the analysis of solid material. That is the reason why the technique was applied for the determination of rare earth elements (REEs) since about 1970. At present, energy-dispersive XRF and wavelength-dispersive XRF are used for the analysis of pressed powder pellets or fused Li-borate beads containing REEs. The production of reliable results can only be achieved by careful optimization of the parameter, in particular the selection of spectral lines. The quantification is based on a calibration realized by using reference samples.

  7. Analysis of obsidian artifacts in Southern Meso-America using x-ray fluorescence

    SciTech Connect

    Nelson, F.W.

    1996-12-31

    The analysis of obsidian artifacts using X-ray fluorescence (XRF) spectrometry has been an important tool for archaeologists for {approximately}25 yr. However, as methods and instrumentation have improved, more reliable information regarding exchange and routes of exchange has been obtained. In southern Meso-America, obsidian analyses have demonstrated changes in the obsidian geologic sources used by prehistoric peoples through time. These changes in sources of obsidian have been used to describe possible changes of prehistoric trade routes. The methods and results of analysis are described in this paper.

  8. Interfacial Microstructures in Multilayer Semiconductors Studied by Grazing Incident X-Ray Scattering and Fluorescence Yield.

    NASA Astrophysics Data System (ADS)

    Ming, Zhi-Hong

    The grazing incident x-ray scattering and fluorescence yield utilizing synchrotron radiation have been used to study multilayer semiconductors consisting of Si _{rm 1-x}Ge_ {rm x} and Si epilayers grown by MBE. The angular dependence of x-ray reflectivity, diffuse scattering and Ge K_{alpha} fluorescence emission have been studied. The research emphasizes on the microstructures of interfaces in these layered structures. The rms interfacial roughness, layer thickness, and optical constants were obtained by fitting measured specular reflectivity data to a theoretical model, which incorporated Fresnel's laws of optics with interfacial roughness. The height fluctuation of interface was associated with a self-affine surface defined in terms of fractional Brownian motion. The lateral-, cross-correlation length and texture coefficient have been obtained by comparison of the transverse and longitudinal diffuse scattering experimental data with theoretical models. The Ge density profile in the epilayer is studied by the angular dependence of Ge K_{alpha} fluorescence yield. The samples studied in this dissertation include bulk Si, normal and inverted SiGe/Si heterostructures, ultrathin Ge layers buried in bulk Si, and SiGe/Si superlattices. The results indicate that normal and inverted SiGe/Si heterointerfaces have similar interfacial microstructures in terms of rms roughness, lateral-correlation length, texture coefficient, and Ge density profile. The evidence of x-ray standing wave has been found in the superlattices. The cross-correlation of interfacial roughness at different interfaces has been observed in superlattice samples and ultrathin Ge layers in Si bulk. The longitudinal diffuse scattering show similar oscillation patterns as reflectivity for these samples. The cross-correlation length for ultrathin Ge layers in Si has been estimated to be comparable with layer thickness. In the EXAFS study of 4 A Ge layer in bulk Si, the lattice strain of Ge layer has been

  9. An x-ray fluorescence study of lake sediments from ancient Turkey using synchrotron radiation.

    SciTech Connect

    Alatas, A.; Alp, E. E.; Friedman, E. S.; Jennings, G.; Johnson, C. E.; Lai, B.; Mini, S. M.; Sato, Y.; Wilkinson, T. J.; Yener, K. A.

    1999-03-10

    Sediments from relic Lake Golbasi were analyzed by X-ray fluorescence with synchrotrons radiation to determine changes in element concentrations over time with selected elements serving as proxies for environmental change. Increases in Ca and Sr suggest soil formation during a dry period, from ca. 4500 BC to ca. 200 AD at which point K, Rb, Zr, Ti, and Y increase, indicating the return of a wet environment. Soil erosion, represented by Cr and Ni, increases ca. 7000 BC, probably as a consequence of environmental change, prior to suggested exploitation of natural resources by the newly urbanized society of the third millennium BC.

  10. Synchrotron total reflection X-ray fluorescence at BL-16 microfocus beamline of Indus-2

    SciTech Connect

    Tiwari, M. K. Singh, A. K. Das, Gangadhar Chowdhury, Anupam Lodha, G. S.

    2014-04-24

    Determination of ultra trace elements is important in many disciplines both in basic and applied sciences. Numerous applications show their importance in medical science, environmental science, materials science, food processing and semiconductor industries and in maintaining the quality control of ultra pure chemicals and reagents. We report commissioning of a synchrotron based total reflection x-ray fluorescence (TXRF) facility on the BL-16 microfocus beamline of Indus-2. This paper describes the performance of the BL-16 TXRF spectrometer and the detailed description of its capabilities through examples of measured results.

  11. Microanalysis of old violin varnishes by total-reflection X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    von Bohlen, Alex; Meyer, Friedrich

    1997-07-01

    Total reflection X-ray fluorescence was used to characterize elements (with Z>13) contained in varnishes applied by prominent violin makers during the last five centuries. Direct analyses of small flakes with masses <20 μg show a variety of elements. Some of these elements could be related to key elements of inorganic pigments and additives used to control some of the properties of a varnish. Higher amounts of Fe, As and Pb were found in old products, Mn, Co, Cu, Zn and Pb were used in more recent varnishes.

  12. Synchrotron based X-ray fluorescence activities at Indus-2: An overview

    SciTech Connect

    Tiwari, M. K.

    2014-04-24

    X-Ray fluorescence (XRF) spectrometry is a powerful non-destructive technique for elemental analysis of materials at bulk and trace concentration levels. Taking into consideration several advantages of the synchrotron based XRF technique and to fulfill the requirements of Indian universities users we have setup a microfocus XRF beamline (BL-16) on Indus-2 synchrotron light source. The beamline offers a wide range of usages – both from research laboratories and industries; and for researchers working in diverse fields. A brief overview of the measured performance of the beamline, design specifications including various attractive features and recent research activities carried out on the BL-16 beamline are presented.

  13. Desert Varnish: Relative and Absolute Dating Using Portable X-Ray Fluorescence

    NASA Astrophysics Data System (ADS)

    Pingitore, N. E.; Lytle, F. W.

    2003-12-01

    Levels of manganese and iron measured in situ with a portable x-ray fluorescence instrument permit relative and absolute dating of desert varnish. This novel technique may have wide potential application to dating Pleistocene and Holocene events and geomorphic surfaces in dry climate settings. Desert varnish is a thin biogenic coating, enriched in Mn and Fe, found on rock surfaces in arid and semi-arid regions. The accumulation of varnish marks the passage of time since a fresh rock surface was created or exposed. Thus the varnish thickness reflects the age of the event that created the fresh surface, whatever the agent was, e.g., a rock fall, a fault movement, or an aboriginal artist. Past attempts to date rock varnish have been marked more by ambiguity or outright failure than by success. Our recent research suggests a practical and rapid method for dating varnish using a portable x-ray fluorescence instrument (PXRF). Varnish thickness encodes two distinct signals, metal and clay. The biogenic Mn and Fe record the passage of time, whereas the accumulation of clay particles is a more time-random process. X-ray fluorescence (XRF) can measure just the "metal thickness" of Mn and Fe in varnish. Earlier tedious microscope techniques focused on physical thickness that includes the noise associated with the clay component. XRF integrates the metal thickness of a broad area of varnish, which is seen to vary significantly in a thin-section traverse. Thus XRF provides a meaningful average thickness over a surface. A portable x-ray fluorescence unit provides rapid, non-destructive, in situ measurements. On outcrop a single analysis takes about 2 minutes and the varnish is not consumed or even disturbed. The hand-held PXRF instrument is simple to operate and relatively inexpensive (\\$ 30,000). PXRF analysis of varnish on independently dated materials yielded a substantive correlation between age and metal (Mn + Fe) thickness. This provided an initial validation of the

  14. The determination of nanogram amounts of Chromium in urine by x-ray fluorescence spectroscopy

    USGS Publications Warehouse

    Beyermann, K.; Rose, H.J.; Christian, R.P.

    1969-01-01

    Nanogram amounts of chromium can be extracted as oxinate into chloform. By treatment of the chloroform layer 3 M hydrochloric acid, oxinates of other elements and excess of reagent are removed, leaving a chloroform solution of the chromium chelate only. This solution is concentrated and transferred to the top of a small brass rod acting as sample holder. The intensity of the X-ray fluorescence of the Cr K?? line is measured with curved crystal optics. Chromium amounts greater than 5 ng can be detected. The application of the procedure to the analysis of the chromium content of urine is demonstrated. ?? 1969.

  15. A new detector system for low energy X-ray fluorescence coupled with soft X-ray microscopy: First tests and characterization

    NASA Astrophysics Data System (ADS)

    Gianoncelli, Alessandra; Bufon, Jernej; Ahangarianabhari, Mahdi; Altissimo, Matteo; Bellutti, Pierluigi; Bertuccio, Giuseppe; Borghes, Roberto; Carrato, Sergio; Cautero, Giuseppe; Fabiani, Sergio; Giacomini, Gabriele; Giuressi, Dario; Kourousias, George; Menk, Ralf Hendrik; Picciotto, Antonino; Piemonte, Claudio; Rachevski, Alexandre; Rashevskaya, Irina; Stolfa, Andrea; Vacchi, Andrea; Zampa, Gianluigi; Zampa, Nicola; Zorzi, Nicola

    2016-04-01

    The last decades have witnessed substantial efforts in the development of several detector technologies for X-ray fluorescence (XRF) applications. In spite of the increasing trend towards performing, cost-effective and reliable XRF systems, detectors for soft X-ray spectroscopy still remain a challenge, requiring further study, engineering and customization in order to yield effective and efficient systems. In this paper we report on the development, first characterization and tests of a novel multielement detector system based on low leakage current silicon drift detectors (SDD) coupled to ultra low noise custom CMOS preamplifiers for synchrotron-based low energy XRF. This new system exhibits the potential for improving the count rate by at least an order of magnitude resulting in ten-fold shorter dwell time at an energy resolution similar to that of single element silicon drift detectors.

  16. Characterization of Japanese color sticks by energy dispersive X-ray fluorescence, X-ray diffraction and Fourier transform infrared analysis

    NASA Astrophysics Data System (ADS)

    Manso, M.; Valadas, S.; Pessanha, S.; Guilherme, A.; Queralt, I.; Candeias, A. E.; Carvalho, M. L.

    2010-04-01

    This work comprises the use of energy dispersive X-ray fluorescence (EDXRF), X-ray diffraction (XRD) and Fourier transformed infrared (FTIR) techniques for the study of the composition of twentieth century traditional Japanese color sticks. By using the combination of analytical techniques it was possible to obtain information on inorganic and organic pigments, binders and fillers present in the sticks. The colorant materials identified in the sticks were zinc and titanium white, chrome yellow, yellow and red ochre, vermillion, alizarin, indigo, Prussian and synthetic ultramarine blue. The results also showed that calcite and barite were used as inorganic mineral fillers while Arabic gum was the medium used. EDXRF offered great potential for such investigations since it allowed the identification of the elements present in the sample preserving its integrity. However, this information alone was not enough to clearly identify some of the materials in study and therefore it was necessary to use XRD and FTIR techniques.

  17. Investigation by laser induced breakdown spectroscopy, X-ray fluorescence and X-ray powder diffraction of the chemical composition of white clay ceramic tiles from Veliki Preslav

    NASA Astrophysics Data System (ADS)

    Blagoev, K.; Grozeva, M.; Malcheva, G.; Neykova, S.

    2013-01-01

    The paper presents the results of the application of laser induced breakdown spectroscopy, X-ray fluorescence spectrometry, and X-ray powder diffraction in assessing the chemical and phase composition of white clay decorative ceramic tiles from the medieval archaeological site of Veliki Preslav, a Bulgarian capital in the period 893-972 AC, well-known for its original ceramic production. Numerous white clay ceramic tiles with highly varied decoration, produced for wall decoration of city's churches and palaces, were found during the archaeological excavations in the old capital. The examination of fourteen ceramic tiles discovered in one of the city's monasteries is aimed at characterization of the chemical profile of the white-clay decorative ceramics produced in Veliki Preslav. Combining different methods and comparing the obtained results provides complementary information regarding the white-clay ceramic production in Veliki Preslav and complete chemical characterization of the examined artefacts.

  18. Case Studies on Facility Characterization with X-Ray Fluorescence Spectrometry

    SciTech Connect

    Kirk, K.T.; Brooksbank, R.D.; Meszaros, J.M.; Towery, W.E.

    2008-01-15

    A hand-held x-ray fluorescence (XRF) analyzer is being used to characterize facilities in support of demolition activities at the East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee. Approximately 500 facilities at the U.S. Department of Energy site are being demolished under the ETTP Decontamination and Decommissioning (D and D) project. Facility characterization is being conducted to provide data for waste profiling and identify hazards to demolition workers. XRF spectrometry is a non-destructive analytical technique used to identify and quantify the elemental composition of a substance based on the intensity of its characteristic X-ray emission wavelength or energy. The Innov-X Systems{sup R} Model XT-245S XRF analyzer used at ETTP is equipped with a silver anode x-ray tube and a Si PIN diode detector. X-rays are generated by electrical current, eliminating the need for radioactive isotopes. Electronic components can be powered by either a lithium-ion battery or an A/C adapter, and the instrument is controlled by an iPAQ{sup R} pocket personal computer. The unit has two primary operating modes. Alloy analysis mode measures percent levels of elements in metals such as a pipes, valves, equipment, or construction materials. Soil mode provides parts-per-million (ppm) quantities in bulk solids like concrete dust, residue, paint chips, or soil. The hand-held unit can analyze material in place, or it can analyze samples in a test stand by remote operation. This paper present some case studies demonstrating a variety of XRF applications for facility characterization: Metal Materials Characterization, Lead Paint Identification, Hot Spot Delineation, Bulk Solids Testing. XRF has been the analytical technique of choice for identifying metal alloy components and has also been useful in analyzing bulk materials. Limitations of XRF testing include the inability to directly analyze elements with low atomic weights. Light elements such as beryllium and aluminum do not

  19. X-ray fluorescent lines from the Compton-thick AGN in M51

    NASA Astrophysics Data System (ADS)

    Xu, Weiwei; Liu, Zhu; Gou, Lijun; Liu, Jiren

    2016-01-01

    The cold disc/torus gas surrounding active galactic nuclei (AGN) emits fluorescent lines when irradiated by hard X-ray photons. The fluorescent lines of elements other than Fe and Ni are rarely detected due to their relative faintness. We report the detection of Kα lines of neutral Si, S, Ar, Ca, Cr, and Mn, along with the prominent Fe Kα, Fe Kβ, and Ni Kα lines, from the deep Chandra observation of the low-luminosity Compton-thick AGN in M51. The Si Kα line at 1.74 keV is detected at ˜3σ, the other fluorescent lines have a significance between 2 and 2.5 σ, while the Cr line has a significance of ˜1.5σ. These faint fluorescent lines are made observable due to the heavy obscuration of the intrinsic spectrum of M51, which is revealed by NuSTAR observation above 10 keV. The hard X-ray continuum of M51 from Chandra and NuSTAR can be fitted with a power-law spectrum with an index of 1.8, reprocessed by a torus with an equatorial column density of NH ˜ 7 × 1024 cm-2 and an inclination angle of 74°. This confirms the Compton-thick nature of the nucleus of M51. The relative element abundances inferred from the fluxes of the fluorescent lines are similar to their solar values, except for Mn, which is about 10 times overabundant. It indicates that Mn is likely enhanced by the nuclear spallation of Fe.

  20. Remote X-ray fluorescence experiments for future missions to Mercury

    NASA Astrophysics Data System (ADS)

    Clark, P. E.; Trombka, J. I.

    1997-01-01

    To date, the only deep space mission to Mercury, Mariner 10, as well as ground-based observations have failed to provide direct measurements of that planet's composition. Such measurements are fundamental for the understanding of Mercury's origin and the inner solar system's history. The spin-stabilized Mercury Orbiter proposed for launch in the first or second decade of the twenty-first century as part of the ESA's Horizon 2000-plus plan could address this problem by including the X-ray spectrometer proposed here. X-ray spectrometers act as detectors for the X-ray emission induced by the solar flux incident on planetary surfaces. This emission is strongly dependent on the chemical composition of the surface as well as on the solar spectrum. Characteristic fluorescent lines, the most prominent being the K-alpha lines, are of sufficient intensity for major elements (Mg, Al, Si, Ca, Fe) to allow orbital measurement by remote X-ray detectors. The X-ray spectrometers described here will all have established heritage for space missions by 2000. These instruments have previously flown, are being flown as part of the NASA NEAR (Near Earth Asteroid Rendezvous) or Clark SSTI (Small Science and Technology Initiative) missions, or are now under development as part of NASA Facility Instrument Development Program. The instrument package would probably consist of an array of solid state detectors for surface measurements, as well as one which would act as a solar monitor. Calculations of anticipated results have been done for a variety of orbital and instrument configurations, and a variety of lunar soil compositions which could be analogous: anorthositie gabbro bearing soils from lunar highlands (Apollo 16), high-Mg basalt-rich soils from a KREEP-bearing area (Apollo 15), and mare basalt bearing soils (Apollo 12). The mission being considered here should result in maps of abundances of major elements, including Mg, Al, Si, Ca, and Fe, for much of Mercury's surface, with

  1. Synchrotron Radiation {mu}-X Ray Fluorescence on Multicellular Tumor Spheroids

    SciTech Connect

    Burattini, E.; Cinque, G.; Bellisola, G.; Fracasso, G.; Colombatti, M.; Monti, F.

    2003-01-24

    Synchrotron Radiation micro X-Ray Fluorescence (SR {mu}-XRF) was applied for the first time to map the trace element content on Multicellular Tumor Spheroids (MTS), i.e. human cell clusters used as an in vitro model for testing micrometastases responses to antitumoral drugs. In particular, immunotoxin molecules composed of a carrier protein (Transferrin) bound to a powerful cytotoxin (Ricin A), were here considered as representatives of a class of therapheutic macromolecules used in cancer theraphy. Spheroids included in polyacrylamide gel and placed inside quartz capillaries were studied at the ESRF ID22 beamline using a 15 keV monochromatic photon microbeam. Elemental maps (of Fe, Cu, Zn and Pb) on four groups of spheroids grown under different conditions were studied: untreated, treated only with the carrier molecule or with the toxin alone, and with the complete immunotoxin molecule (carrier+toxin). The results indicate that the distribution of Zn and, to some extent, Cu in the spheroid cells is homogeneous and independent of the treatment type. Total Reflection X-Ray Fluorescence (TR-XRF) was also applied to quantify the average trace element content in the spheroids. Future developments of the technique are finally outlined on the basis of these preliminary results.

  2. Study of gold nanoparticle synthesis by synchrotron x-ray diffraction and fluorescence

    NASA Astrophysics Data System (ADS)

    Yan, Zhongying; Wang, Xiao; Yu, Le; Moeendarbari, Sina; Hao, Yaowu; Cai, Zhonghou; Cheng, Xuemei

    Gold nanoparticles have a wide range of potential applications, including therapeutic agent delivery, catalysis, and electronics. Recently a new process of hollow nanoparticle synthesis was reported, the mechanism of which was hypothesized to involve electroless deposition around electrochemically evolved hydrogen bubbles. However, the growth mechanism still needs experimental evidence. We report investigation of this synthesis process using synchrotron x-ray diffraction and fluorescence measurements performed at beamline 2-ID-D of the Advanced Photon Source (APS). A series of gold nanoparticle samples with different synthesis time (50-1200 seconds) were deposited using a mixture electrolyte solution of Na3Au(SO3)2 and H4N2NiO6S2 on anodic aluminum oxide (AAO) membranes. The 2D mapping of fluorescence intensity and comparison of x-ray diffraction peaks of the samples have provided valuable information on the growth mechanism. Work at Bryn Mawr College and University of Texas at Arlington is supported by NSF Grants (1207085 and 1207377) and use of the APS at Argonne National Laboratory is supported by the U. S. Department of Energy under Contract No. DE-AC02-06CH11357.

  3. Mapping Metal Elements of Shuangbai Dinosaur Fossil by Synchrotron X-ray Fluorescence Microprobe

    SciTech Connect

    Wang, Y.; Qun, Y; Ablett, J

    2008-01-01

    The metal elements mapping of Shuangbai dinosaur fossil, was obtained by synchrotron x-ray fluorescence (SXRF). Eight elements, Ca, Mn, Fe, Cu, Zn, As, Y and Sr were determined. Elements As and Y were detected for the first time in the dinosaur fossil. The data indicated that metal elements are asymmetrical on fossil section. This is different from common minerals. Mapping metals showed that metal element As is few. The dinosaur most likely belongs to natural death. This is different from Zigong dinosaurs which were found dead from poisoning. This method has been used to find that metals Fe and Mn are accrete, and the same is true for Sr and Y. This study indicated that colloid granule Fe and Mn, as well as Sr and Y had opposite electric charges in lithification process of fossils. By this analysis, compound forms can be ascertained. Synchrotron light source x-ray fluorescence is a complementary method that shows mapping of metal elements at the dinosaur fossil, and is rapid, exact and intuitionist. This study shows that dinosaur fossil mineral imaging has a potential in reconstructing the paleoenvironment and ancient geology.

  4. Determination of selenium in biological samples with an energy-dispersive X-ray fluorescence spectrometer.

    PubMed

    Li, Xiaoli; Yu, Zhaoshui

    2016-05-01

    Selenium is both a nutrient and a toxin. Selenium-especially organic selenium-is a core component of human nutrition. Thus, it is very important to measure selenium in biological samples. The limited sensitivity of conventional XRF hampers its widespread use in biological samples. Here, we describe the use of high-energy (100kV, 600W) linearly polarized beam energy-dispersive X-Ray fluorescence spectroscopy (EDXRF) in tandem with a three-dimensional optics design to determine 0.1-5.1μgg(-1) levels of selenium in biological samples. The effects of various experimental parameters such as applied voltage, acquisition time, secondary target and various filters were thoroughly investigated. The detection limit of selenium in biological samples via high-energy (100kV, 600W) linearly polarized beam energy-dispersive X-ray fluorescence spectroscopy was decreased by one order of magnitude versus conventional XRF (Paltridge et al., 2012) and found to be 0.1μg/g. To the best of our knowledge, this is the first report to describe EDXRF measurements of Se in biological samples with important implications for the nutrition and analytical chemistry communities. PMID:26922394

  5. Screening heavy metals levels in hair of sanitation workers by X-ray fluorescence analysis.

    PubMed

    Md Khudzari, Jauharah; Wagiran, Husin; Hossain, I; Ibrahim, Noorddin

    2013-01-01

    This work presents a study of human hair as a bio-indicator for detection of heavy metals as part of environmental health surveillance programs project to develop a subject of interest in the biomedical and environmental sciences. A total of 34 hair samples were analyzed that consisting of 29 samples from sanitation workers and five samples from students. The hair samples were prepared and treated in accordance to the International Atomic Energy Agency (IAEA) recommendations. The concentrations of heavy metals were analyzed using the energy dispersive X-ray fluorescence (EDXRF) technique by X-50 Mobile X-ray Fluorescence (XRF) at Oceanography Institute, Universiti Malaysia Terengganu. The performance of EDXRF analyzer was tested by Standard Reference Material (SRM 2711) Montana Soil which was in good agreement with certified value within 14% deviations except for Hg. While seven heavy metals: Mn, Fe, Ni, Cu, Zn, Se, and Sb were detected in both groups, three additional elements, i.e. As, Hg and Pb, were detected only in sanitation workers group. For sanitation workers group, the mean concentration of six elements, Mn, Fe, Cu, Zn, Se, and Sb, shows elevated concentration as compared to the control samples concentration. Results from both groups were compared and discussed in relation to their respective heavy metals concentrations. PMID:22846873

  6. Spectral Interferences Manganese (Mn) - Europium (Eu) Lines in X-Ray Fluorescence Spectrometry Spectrum

    NASA Astrophysics Data System (ADS)

    Tanc, Beril; Kaya, Mustafa; Gumus, Lokman; Kumral, Mustafa

    2016-04-01

    X-ray fluorescence (XRF) spectrometry is widely used for quantitative and semi quantitative analysis of many major, minor and trace elements in geological samples. Some advantages of the XRF method are; non-destructive sample preparation, applicability for powder, solid, paste and liquid samples and simple spectrum that are independent from chemical state. On the other hand, there are some disadvantages of the XRF methods such as poor sensitivity for low atomic number elements, matrix effect (physical matrix effects, such as fine versus course grain materials, may impact XRF performance) and interference effect (the spectral lines of elements may overlap distorting results for one or more elements). Especially, spectral interferences are very significant factors for accurate results. In this study, semi-quantitative analyzed manganese (II) oxide (MnO, 99.99%) was examined. Samples were pelleted and analyzed with XRF spectrometry (Bruker S8 Tiger). Unexpected peaks were obtained at the side of the major Mn peaks. Although sample does not contain Eu element, in results 0,3% Eu2O3 was observed. These result can occur high concentration of MnO and proximity of Mn and Eu lines. It can be eliminated by using correction equation or Mn concentration can confirm with other methods (such as Atomic absorption spectroscopy). Keywords: Spectral Interferences; Manganese (Mn); Europium (Eu); X-Ray Fluorescence Spectrometry Spectrum.

  7. Analytical approaches for determination of bromine in sediment core samples by X-ray fluorescence spectrometry.

    PubMed

    Pashkova, Galina V; Aisueva, Tatyana S; Finkelshtein, Alexander L; Ivanov, Egor V; Shchetnikov, Alexander A

    2016-11-01

    Bromine has been recognized as a valuable indicator for paleoclimatic studies. Wavelength dispersive X-ray fluorescence (WDXRF) and total reflection X-ray fluorescence (TXRF) methods were applied to study the bromine distributions in lake sediment cores. Conventional WDXRF technique usually requires relatively large mass of a sediment sample and a set of calibration samples. Some analytical approaches were developed to apply WDXRF to small sediment core samples in the absence of adequate calibration samples with a known Br content. The mass of a sample to be analyzed was reduced up to 200-300mg and the internal standard method with correction using fundamental parameters was developed for Br quantification. TXRF technique based on the direct analysis of a solid suspension using 20mg of sediment sample by internal standard method was additionally tested. The accuracy of the WDXRF and TXRF techniques was assessed by the comparative analysis of reference materials of sediments, soil and biological samples. In general, good agreement was achieved between the reference values and the measured values. The detection limits of Br were 1mg/kg and 0.4mg/kg for WDXRF and TXRF respectively. The results of the Br determination obtained with different XRF techniques were comparable to each other and used for paleoclimatic reconstructions. PMID:27591627

  8. [Application of the racial algorithm in energy dispersive X-ray fluorescence overlapped spectrum analysis].

    PubMed

    Zeng, Guo-Qiang; Luo, Yao-Yao; Ge, Liang-Quan; Zhang, Qing-Xian; Gu, Yi; Cheng, Feng

    2014-02-01

    In the energy dispersive X-ray fluorescence spectrum analysis, scintillation detector such as NaI (Tl) detector usually has a low energy resolution at around 8%. The low energy resolution causes problems in spectral data analysis especially in the high background and low counts condition, it is very limited to strip the overlapped spectrum, and the more overlapping the peaks are, the more difficult to peel the peaks, and the qualitative and quantitative analysis can't be carried out because we can't recognize the peak address and peak area. Based on genetic algorithm and immune algorithm, we build a new racial algorithm which uses the Euclidean distance as the judgment of evolution, the maximum relative error as the iterative criterion to be put into overlapped spectrum analysis, then we use the Gaussian function to simulate different overlapping degrees of the spectrum, and the racial algorithm is used in overlapped peak separation and full spectrum simulation, the peak address deviation is in +/- 3 channels, the peak area deviation is no more than 5%, and it is proven that this method has a good effect in energy dispersive X-ray fluorescence overlapped spectrum analysis.

  9. A robust X-ray fluorescence technique for multielemental analysis of solid samples.

    PubMed

    Kallithrakas-Kontos, Nikolaos; Foteinis, Spyros; Paigniotaki, Katherine; Papadogiannakis, Minos

    2016-02-01

    X-ray fluorescence (XRF) quantitation software programs are widely used for analyzing environmental samples due to their versatility but at the expense of accuracy. In this work, we propose an accurate, robust, and versatile technique for multielemental X-ray fluorescence analytical applications, by spiking solid matrices with standard solutions. National Institute of Standards and Technology (NIST)-certified soil standards were spiked with standard solutions, mixed well, desiccated, and analyzed by an energy dispersive XRF. Homogenous targets were produced and low error calibration curves, for the added and not added, neighboring, elements, were obtained. With the addition of few elements, the technique provides reliable multielemental analysis, even for concentrations of the order of milligram per kilogram (ppm). When results were compared to the ones obtained from XRF commercial quantitation software programs, which are widely used in environmental monitoring and assessment applications, they were found to fit certified values better. Moreover, in all examined cases, results were reliable. Hence, this technique can also be used to overcome difficulties associated with interlaboratory consistency and for cross-validating results. The technique was applied to samples with an environmental interest, collected from a ship/boat repainting area. Increased copper, zinc, and lead loads were observed (284, 270, and 688 mg/kg maximum concentrations in soil, respectively), due to vessels being paint stripped and repainted.

  10. Analytical approaches for determination of bromine in sediment core samples by X-ray fluorescence spectrometry.

    PubMed

    Pashkova, Galina V; Aisueva, Tatyana S; Finkelshtein, Alexander L; Ivanov, Egor V; Shchetnikov, Alexander A

    2016-11-01

    Bromine has been recognized as a valuable indicator for paleoclimatic studies. Wavelength dispersive X-ray fluorescence (WDXRF) and total reflection X-ray fluorescence (TXRF) methods were applied to study the bromine distributions in lake sediment cores. Conventional WDXRF technique usually requires relatively large mass of a sediment sample and a set of calibration samples. Some analytical approaches were developed to apply WDXRF to small sediment core samples in the absence of adequate calibration samples with a known Br content. The mass of a sample to be analyzed was reduced up to 200-300mg and the internal standard method with correction using fundamental parameters was developed for Br quantification. TXRF technique based on the direct analysis of a solid suspension using 20mg of sediment sample by internal standard method was additionally tested. The accuracy of the WDXRF and TXRF techniques was assessed by the comparative analysis of reference materials of sediments, soil and biological samples. In general, good agreement was achieved between the reference values and the measured values. The detection limits of Br were 1mg/kg and 0.4mg/kg for WDXRF and TXRF respectively. The results of the Br determination obtained with different XRF techniques were comparable to each other and used for paleoclimatic reconstructions.

  11. X-ray fluorescence and absorption analysis of krypton in irradiated nuclear fuel

    NASA Astrophysics Data System (ADS)

    Degueldre, Claude; Mieszczynski, Cyprian; Borca, Camelia; Grolimund, Daniel; Martin, Matthias; Bertsch, Johannes

    2014-10-01

    The analysis of krypton in irradiated uranium dioxide fuel has been successfully achieved by X-ray fluorescence and X-ray absorption. The present study focuses on the analytical challenge of sample and sub-sample production to perform the analysis with the restricted conditions dictated by the radioprotection regulations. It deals also with all potential interferences that could affect the quality of the measurement in fluorescence as well as in absorption mode. The impacts of all dissolved gases in the fuel matrix are accounted for the analytical result quantification. The krypton atomic environment is ruled by the presence of xenon. Other gases such as residual argon and traces of helium or hydrogen are negligible. The results are given in term of density for krypton (∼3 nm-3) and xenon (∼20 nm-3). The presence of dissolved, interstitial and nano-phases are discussed together with other analytical techniques that could be applied to gain information on fission gas behaviour in nuclear fuels.

  12. Elemental concentration analysis in prostate tissues using total reflection X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Leitão, R. G.; Palumbo, A.; Souza, P. A. V. R.; Pereira, G. R.; Canellas, C. G. L.; Anjos, M. J.; Nasciutti, L. E.; Lopes, R. T.

    2014-02-01

    Prostate cancer (PCa) currently represents the second most prevalent malignant neoplasia in men, representing 21% of all cancer cases. Benign Prostate Hyperplasia (BPH) is an illness prevailing in men above the age of 50, close to 90% after the age of 80. The prostate presents a high zinc concentration, about 10-fold higher than any other body tissue. In this work, samples of human prostate tissues with cancer, BPH and normal tissue were analyzed utilizing total reflection X-ray fluorescence spectroscopy using synchrotron radiation technique (SR-TXRF) to investigate the differences in the elemental concentrations in these tissues. SR-TXRF analyses were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, São Paulo. It was possible to determine the concentrations of the following elements: P, S, K, Ca, Fe, Cu, Zn and Rb. By using Mann-Whitney U test it was observed that almost all elements presented concentrations with significant differences (α=0.05) between the groups studied.

  13. Synchrotron Radiation μ-X Ray Fluorescence on Multicellular Tumor Spheroids

    NASA Astrophysics Data System (ADS)

    Burattini, E.; Cinque, G.; Bellisola, G.; Fracasso, G.; Monti, F.; Colombatti, M.

    2003-01-01

    Synchrotron Radiation micro X-Ray Fluorescence (SR μ-XRF) was applied for the first time to map the trace element content on Multicellular Tumor Spheroids (MTS), i.e. human cell clusters used as an in vitro model for testing micrometastases responses to antitumoral drugs. In particular, immunotoxin molecules composed of a carrier protein (Transferrin) bound to a powerful cytotoxin (Ricin A), were here considered as representatives of a class of therapheutic macromolecules used in cancer theraphy. Spheroids included in polyacrylamide gel and placed inside quartz capillaries were studied at the ESRF ID22 beamline using a 15 keV monochromatic photon microbeam. Elemental maps (of Fe, Cu, Zn and Pb) on four groups of spheroids grown under different conditions were studied: untreated, treated only with the carrier molecule or with the toxin alone, and with the complete immunotoxin molecule (carrier+toxin). The results indicate that the distribution of Zn and, to some extent, Cu in the spheroid cells is homogeneous and independent of the treatment type. Total Reflection X-Ray Fluorescence (TR-XRF) was also applied to quantify the average trace element content in the spheroids. Future developments of the technique are finally outlined on the basis of these preliminary results.

  14. The reproducibility of 109Cd-based X-ray fluorescence measurements of bone lead.

    PubMed Central

    Gordon, C L; Webber, C E; Chettle, D R

    1994-01-01

    We assessed the reproducibility of X-ray fluorescence-based lead measurements from multiple measurements made on a low-concentration plaster of paris phantom and in five subjects measured five times on two occasions. Over a 6-month period, 220 measurements of the same phantom were obtained and showed a standard deviation of 1.29 micrograms Pb (g plaster of paris)-1. The two sets of in vivo measurements were made 10 months apart and revealed a mean standard deviation of 3.4 micrograms Pb (g bone mineral)-1 and 5.1 micrograms Pb (g bone mineral)-1 for males and females, respectively. Our measured standard deviation exceeded by 20-30% the calculated standard deviation associated with a single measurement both in the phantom and in subjects. This indicates that some variance is introduced during the measurement process. Operator learning and consistency significantly minimized this increased variability. Measured lead concentrations of the left and right tibia in 14 subjects showed no significant differences between legs. As a result, either tibia can be sampled and compared over time. The levels of reproducibility we report here mean that X-ray fluorescence-based determinations of bone lead concentrations are reliable both over the short and long term. Thus, reasonably sized confidence intervals can be placed on detected changes in concentration and should permit acquisition of longitudinal data within a reasonable length of time. Images Figure 1. PMID:7895710

  15. Combined evaluation of grazing incidence X-ray fluorescence and X-ray reflectivity data for improved profiling of ultra-shallow depth distributions

    NASA Astrophysics Data System (ADS)

    Ingerle, D.; Meirer, F.; Pepponi, G.; Demenev, E.; Giubertoni, D.; Wobrauschek, P.; Streli, C.

    2014-09-01

    The continuous downscaling of the process size for semiconductor devices pushes the junction depths and consequentially the implantation depths to the top few nanometers of the Si substrate. This motivates the need for sensitive methods capable of analyzing dopant distribution, total dose and possible impurities. X-ray techniques utilizing the external reflection of X-rays are very surface sensitive, hence providing a non-destructive tool for process analysis and control. X-ray reflectometry (XRR) is an established technique for the characterization of single- and multi-layered thin film structures with layer thicknesses in the nanometer range. XRR spectra are acquired by varying the incident angle in the grazing incidence regime while measuring the specular reflected X-ray beam. The shape of the resulting angle-dependent curve is correlated to changes of the electron density in the sample, but does not provide direct information on the presence or distribution of chemical elements in the sample. Grazing Incidence XRF (GIXRF) measures the X-ray fluorescence induced by an X-ray beam incident under grazing angles. The resulting angle dependent intensity curves are correlated to the depth distribution and mass density of the elements in the sample. GIXRF provides information on contaminations, total implanted dose and to some extent on the depth of the dopant distribution, but is ambiguous with regard to the exact distribution function. Both techniques use similar measurement procedures and data evaluation strategies, i.e. optimization of a sample model by fitting measured and calculated angle curves. Moreover, the applied sample models can be derived from the same physical properties, like atomic scattering/form factors and elemental concentrations; a simultaneous analysis is therefore a straightforward approach. This combined analysis in turn reduces the uncertainties of the individual techniques, allowing a determination of dose and depth profile of the implanted

  16. Medieval glass from the Cathedral in Paderborn: a comparative study using X-ray absorption spectroscopy, X-ray fluorescence, and inductively coupled laser ablation mass spectrometry

    NASA Astrophysics Data System (ADS)

    Hormes, J.; Roy, A.; Bovenkamp, G.-L.; Simon, K.; Kim, C.-Y.; Börste, N.; Gai, S.

    2013-04-01

    We have investigated four stained glass samples recovered from an archaeological excavation at the Cathedral in Paderborn (Germany) between 1978 and 1980. On two of the samples there are parts of paintings. Concentrations of major elements were determined using two independent techniques: LA-ICP-MS (a UV laser ablation microsampler combined with an inductively coupled plasma mass spectrometer) and synchrotron radiation X-ray excited X-ray fluorescence (SR-XRF). The SR-XRF data were quantified by using the program package PyMCA developed by the software group of the ESRF in Grenoble. Significant differences were found between the concentrations determined by the two techniques that can be explained by concentration gradients near the surface of the glasses caused, for example, by corrosion/leaching processes and the different surface sensitivities of the applied techniques. For several of the elements that were detected in the glass and in the colour pigments used for the paintings X-ray absorption near edge structure (XANES) spectra were recorded in order to determine the chemical speciation of the elements of interest. As was expected, most elements in the glass were found as oxides in their most stable form. Two notable exceptions were observed: titanium was not found as rutile—the most stable form of TiO2—but in the form of anatase, and lead was not found in one defined chemical state but as a complex mixture of oxide, sulphate, and other compounds.

  17. The BioCAT Microprobe for X-Ray Fluorescence Imaging, MicroXAFS and Microdiffraction Studies on Biological Samples

    SciTech Connect

    Barrea, R.A.; Gore, D.; Kondrashkina, E.; Weng, T.; Heurich, R.; Vukonich, M.; Orgel, J.; Davidson, M.; Collingwood, J.F.; Mikhaylova, A.; Irving, T.C.

    2007-07-31

    Microbeam capabilities have been recently added to the Biophysics Collaborative Access Team (BioCAT) beamline 18-ID at the Advanced Photon Source to allow x-ray elemental mapping, micro x-ray absorption fine structure and microdiffraction studies on biological samples. The microprobe setup comprises a pair of platinum coated silicon KB mirrors; a sample holder mounted in a high precision positioner (100 nm accuracy); fluorescence detectors including a Si drift detector, Fe and Zn Bent Laue analyzers and a Ge detector; and a CCD detector for micro-diffraction experiments. The energy range of the microprobe is from 3.5 keV up to 17 keV. The fast scanning capabilities of the Bio-CAT beamline facilitate rapid acquisition of x-ray elemental images and micro-XAFS spectra. This paper reports the results of commissioning the KB mirror system and its performance in initial x-ray fluorescence mapping and micro-diffraction studies.

  18. Comparison of the data of X-ray microtomography and fluorescence analysis in the study of bone-tissue structure

    NASA Astrophysics Data System (ADS)

    Asadchikov, V. E.; Senin, R. A.; Blagov, A. E.; Buzmakov, A. V.; Gulimova, V. I.; Zolotov, D. A.; Orekhov, A. S.; Osadchaya, A. S.; Podurets, K. M.; Savel'ev, S. V.; Seregin, A. Yu.; Tereshchenko, E. Yu.; Chukalina, M. V.; Kovalchuk, M. V.

    2012-09-01

    The possibility of localizing clusters of heavy atoms is substantiated by comparing the data of X-ray microtomography at different wavelengths, scanning electron microscopy, and X-ray fluorescence analysis. The proximal tail vertebrae of Turner's thick-toed gecko ( Chondrodactylus turneri) have been investigated for the first time by both histological and physical methods, including X-ray microtomography at different wavelengths and elemental analysis. This complex methodology of study made it possible to reveal the regions of accumulation of heavy elements in the aforementioned bones of Turner's thick-toed gecko.

  19. Contribution of inner shell Compton ionization to the X-ray fluorescence line intensity

    NASA Astrophysics Data System (ADS)

    Fernández, Jorge E.; Scot, Viviana; Di Giulio, Eugenio

    2016-10-01

    The Compton effect is a potential ionization mechanism of atoms. It produces vacancies in inner shells that are filled with the same mechanism of atomic relaxation as the one following photo-absorption. This contribution to X-ray fluorescence emission is frequently neglected because the total Compton cross-section is apparently much lower than the photoelectric one at useful X-ray energies. However, a more careful analysis suggests that is necessary to consider single shell cross sections (instead of total cross sections) as a function of energy. In this article these Compton cross sections are computed for the shells K, L1-L3 and M1-M5 in the framework of the impulse approximation. By comparing the Compton and the photoelectric cross-section for each shell it is then possible to determine the extent of the Compton correction to the intensity of the corresponding characteristic lines. It is shown that for the K shell the correction becomes relevant for excitation energies which are too high to be influent in X-ray spectrometry. In contrast, for L and M shells the Compton contribution is relevant for medium-Z elements and medium energies. To illustrate the different grades of relevance of the correction, for each ionized shell, the energies for which the Compton contribution reaches the extent levels of 1, 5, 10, 20, 50 and 100% of the photoelectric one are determined for all the elements with Z = 11-92. For practical applications it is provided a simple formula and fitting coefficients to compute average correction levels for the shells considered.

  20. Measuring lead, mercury, and uranium by in vivo X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    O'Meara, Joanne Michelle

    X-ray fluorescence (XRF) has been demonstrated to be a useful technique for measuring trace quantities of heavy metals in various tissues within the body. This thesis investigates a means of improving the measurement of lead in bone, as well as increasing the existing sensitivity of measuring kidney mercury content. The XRF measurement of uranium is also explored. This work assesses the feasibility of a normalisation method for the 57Co/90° system, in relating detected signal to the lead content of the sample. The feasibility of normalisation has been shown, which reduces subject dose and improves system transportability, as well as removes subjectivity, by eliminating the need for acquiring planar x-ray images of the measurement site. In the measurement of renal mercury concentrations, a gain in sensitivity increasing the x-ray tube operating voltage of the current system is investigated. It found that 250 kV, rather than 175 kV, and a titanium rather than uranium filter, results in a 2.5 +/- 0.2 times gain in sensitivity. This potential improvement could have profound clinical implications for the accuracy of occupational monitoring, and for assessing whether there is a quantitative relationship between biological fluid levels and mercury content in this critical organ. The XRF measurement of bone uranium content is also explored. Both source-excited and polarised systems have been developed, however, the sensitivity is currently beyond that which is useful for occupational monitoring of exposure to this toxin. The particular case of measuring uranium in survivors of "Friendly Fire" incidents (from Operation Desert Storm) is investigated, and the first detectable quantity of uranium has been observed in a member of this cohort, with the XRF system designed and built during the course of this work.

  1. Micro energy dispersive X-ray fluorescence analysis of polychrome lead-glazed Portuguese faiences

    NASA Astrophysics Data System (ADS)

    Guilherme, A.; Pessanha, S.; Carvalho, M. L.; dos Santos, J. M. F.; Coroado, J.

    2010-04-01

    Several glazed ceramic pieces, originally produced in Coimbra (Portugal), were submitted to elemental analysis, having as premise the pigment manufacture production recognition. Although having been produced in Coimbra, their location changed as time passed due to historical reasons. A recent exhibition in Coimbra brought together a great number of these pieces and in situ micro Energy Dispersive X-ray Fluorescence (µ-EDXRF) analyses were performed in order to achieve some chemical and physical data on the manufacture of faiences in Coimbra. A non-commercial µ-EDXRF equipment for in situ analysis was employed in this work, carrying some important improvements when compared to the conventional ones, namely, analyzing spot sizes of about 100 µm diameter. The combination of a capillary X-ray lens with a new generation of low power microfocus X-ray tube and a drift chamber detector enabled a portable unit for micro-XRF with a few tens of µm lateral resolution. The advantages in using a portable system emphasized with polycapillary optics enabled to distinguish proximal different pigmented areas, as well as the glaze itself. These first scientific results on the pigment analysis of the collection of faiences seem to point to a unique production center with own techniques and raw materials. This conclusion arose with identification of the blue pigments having in its constitution Mn, Fe Co and As and the yellows as a result of the combination between Pb and Sb. A statistical treatment was used to reveal groups of similarities on the pigments elemental profile.

  2. Resonant inelastic scattering in dilute magnetic semiconductors by x-ray fluorescence spectroscopy

    SciTech Connect

    Lawniczak-Jablonska, K. |; Jia, J.J.; Underwood, J.H.

    1997-04-01

    As modern, technologically important materials have become more complex, element specific techniques have become invaluable in studying the electronic structure of individual components from the system. Soft x-ray fluorescence (SXF) and absorption (SXA) spectroscopies provide a unique means of measuring element and angular momentum density of electron states, respectively, for the valence and conducting bands in complex materials. X-ray absorption and the decay through x-ray emission are generally assumed to be two independent one-photon processes. Recent studies, however have demonstrated that SXF excited near the absorption threshold generate an array of spectral features that depend on nature of materials, particularly on the localization of excited states in s and d-band solids and that these two processes can no be longer treated as independent. Resonant SXF offers thus the new way to study the dynamics of the distribution of electronic valence states in the presence of a hole which is bound to the electron low lying in the conduction band. This process can simulate the interaction between hole-electron pair in wide gap semiconductors. Therefore such studies can help in understanding of transport and optics phenomena in the wide gap semiconductors. The authors report the result of Mn and S L-resonant emission in Zn{sub 1{minus}x}Mn{sub x}S (with x=0.2 and 0.3) and MnS as the energy of exciting radiation is tuned across the Mn and S L{sub 3,2} absorption edge, along with the resonant excited spectra from elemental Mn as a reference.

  3. C-library raft : Reconstruction algorithms for tomography. Applications to X-ray fluorescence tomography

    NASA Astrophysics Data System (ADS)

    Miqueles, Eduardo X.; De Pierro, Alvaro R.

    2011-12-01

    There are many reconstruction algorithms for tomography, raft for short, and some of them are considered "classic" by researchers. The so-called raft library, provide a set of useful and basic tools, usually needed in many inverse problems that are related to medical imaging. The subroutines in raft are free software and written in C language; portable to any system with a working C compiler. This paper presents source codes written according to raft routines, applied to a new imaging modality called X-ray fluorescence tomography. Program summaryProgram title: raft Catalogue identifier: AEJY_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEJY_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU General Public Licence, version 2 No. of lines in distributed program, including test data, etc.: 218 844 No. of bytes in distributed program, including test data, etc.: 3 562 902 Distribution format: tar.gz Programming language: Standard C. Computer: Any with a standard C compiler Operating system: Linux and Windows Classification: 2.4, 2.9, 3, 4.3, 4.7 External routines: raft: autoconf 2.60 or later - http://www.gnu.org/software/autoconf/ GSL scientific library - http://www.gnu.org/software/gsl/ Confuse parser library - http://www.nongnu.org/confuse/ raft-fun: gengetopt - http://www.gnu.org/software/gengetopt/gengetopt.html Nature of problem: Reconstruction algorithms for tomography, specially in X-ray fluorescence tomography. Solution method: As a library, raft covers the standard reconstruction algorithms like filtered backprojection, Novikov's inversion, Hogan's formula, among others. The input data set is represented by a complete sinogram covering a determined angular range. Users are allowed to set solid angle range for fluorescence emission at each algorithm. Running time: 1 second to 15 minutes, depending on the data size.

  4. Electrochemical X-ray fluorescence spectroscopy for trace heavy metal analysis: enhancing X-ray fluorescence detection capabilities by four orders of magnitude.

    PubMed

    Hutton, Laura A; O'Neil, Glen D; Read, Tania L; Ayres, Zoë J; Newton, Mark E; Macpherson, Julie V

    2014-05-01

    The development of a novel analytical technique, electrochemical X-ray fluorescence (EC-XRF), is described and applied to the quantitative detection of heavy metals in solution, achieving sub-ppb limits of detection (LOD). In EC-XRF, electrochemical preconcentration of a species of interest onto the target electrode is achieved here by cathodic electrodeposition. Unambiguous elemental identification and quantification of metal concentration is then made using XRF. This simple electrochemical preconcentration step improves the LOD of energy dispersive XRF by over 4 orders of magnitude (for similar sample preparation time scales). Large area free-standing boron doped diamond grown using microwave plasma chemical vapor deposition techniques is found to be ideal as the electrode material for both electrodeposition and XRF due to its wide solvent window, transparency to the XRF beam, and ability to be produced in mechanically robust freestanding thin film form. During electrodeposition it is possible to vary both the deposition potential (Edep) and deposition time (tdep). For the metals Cu(2+) and Pb(2+) the highest detection sensitivities were found for Edep = -1.75 V and tdep (=) 4000 s with LODs of 0.05 and 0.04 ppb achieved, respectively. In mixed Cu(2+)/Pb(2+) solutions, EC-XRF shows that Cu(2+) deposition is unimpeded by Pb(2+), across a broad concentration range, but this is only true for Pb(2+) when both metals are present at low concentrations (10 nM), boding well for trace level measurements. In a dual mixed metal solution, EC-XRF can also be employed to either selectively deposit the metal which has the most positive formal reduction potential, E(0), or exhaustively deplete it from solution, enabling uninhibited detection of the metal with the more negative E(0).

  5. Experimental demonstration of direct L-shell x-ray fluorescence imaging of gold nanoparticles using a benchtop x-ray source

    SciTech Connect

    Manohar, Nivedh; Reynoso, Francisco J.; Cho, Sang Hyun

    2013-08-15

    Purpose: To develop a proof-of-principle L-shell x-ray fluorescence (XRF) imaging system that locates and quantifies sparse concentrations of gold nanoparticles (GNPs) using a benchtop polychromatic x-ray source and a silicon (Si)-PIN diode x-ray detector system.Methods: 12-mm-diameter water-filled cylindrical tubes with GNP concentrations of 20, 10, 5, 0.5, 0.05, 0.005, and 0 mg/cm{sup 3} served as calibration phantoms. An imaging phantom was created using the same cylindrical tube but filled with tissue-equivalent gel containing structures mimicking a GNP-loaded blood vessel and approximately 1 cm{sup 3} tumor. Phantoms were irradiated by a 3-mm-diameter pencil-beam of 62 kVp x-rays filtered by 1 mm aluminum. Fluorescence/scatter photons from phantoms were detected at 90° with respect to the beam direction using a Si-PIN detector placed behind a 2.5-mm-diameter lead collimator. The imaging phantom was translated horizontally and vertically in 0.3-mm steps to image a 6 mm × 15 mm region of interest (ROI). For each phantom, the net L-shell XRF signal from GNPs was extracted from background, and then corrected for detection efficiency and in-phantom attenuation using a fluorescence-to-scatter normalization algorithm.Results: XRF measurements with calibration phantoms provided a calibration curve showing a linear relationship between corrected XRF signal and GNP mass per imaged voxel. Using the calibration curve, the detection limit (at the 95% confidence level) of the current experimental setup was estimated to be a GNP mass of 0.35 μg per imaged voxel (1.73 × 10{sup −2} cm{sup 3}). A 2D XRF map of the ROI was also successfully generated, reasonably matching the known spatial distribution as well as showing the local variation of GNP concentrations.Conclusions: L-shell XRF imaging can be a highly sensitive tool that has the capability of simultaneously imaging the spatial distribution and determining the local concentration of GNPs presented on the order of

  6. Experimental demonstration of direct L-shell x-ray fluorescence imaging of gold nanoparticles using a benchtop x-ray source

    PubMed Central

    Manohar, Nivedh; Reynoso, Francisco J.; Cho, Sang Hyun

    2013-01-01

    Purpose: To develop a proof-of-principle L-shell x-ray fluorescence (XRF) imaging system that locates and quantifies sparse concentrations of gold nanoparticles (GNPs) using a benchtop polychromatic x-ray source and a silicon (Si)-PIN diode x-ray detector system. Methods: 12-mm-diameter water-filled cylindrical tubes with GNP concentrations of 20, 10, 5, 0.5, 0.05, 0.005, and 0 mg/cm3 served as calibration phantoms. An imaging phantom was created using the same cylindrical tube but filled with tissue-equivalent gel containing structures mimicking a GNP-loaded blood vessel and approximately 1 cm3 tumor. Phantoms were irradiated by a 3-mm-diameter pencil-beam of 62 kVp x-rays filtered by 1 mm aluminum. Fluorescence/scatter photons from phantoms were detected at 90° with respect to the beam direction using a Si-PIN detector placed behind a 2.5-mm-diameter lead collimator. The imaging phantom was translated horizontally and vertically in 0.3-mm steps to image a 6 mm × 15 mm region of interest (ROI). For each phantom, the net L-shell XRF signal from GNPs was extracted from background, and then corrected for detection efficiency and in-phantom attenuation using a fluorescence-to-scatter normalization algorithm. Results: XRF measurements with calibration phantoms provided a calibration curve showing a linear relationship between corrected XRF signal and GNP mass per imaged voxel. Using the calibration curve, the detection limit (at the 95% confidence level) of the current experimental setup was estimated to be a GNP mass of 0.35 μg per imaged voxel (1.73 × 10−2 cm3). A 2D XRF map of the ROI was also successfully generated, reasonably matching the known spatial distribution as well as showing the local variation of GNP concentrations. Conclusions:L-shell XRF imaging can be a highly sensitive tool that has the capability of simultaneously imaging the spatial distribution and determining the local concentration of GNPs presented on the order of parts-per-million level

  7. Detection of Fingerprints Based on Elemental Composition Using Micro-X-Ray Fluorescence.

    SciTech Connect

    Worley, C. G.; Wiltshire, S.; Miller, T. C.; Havrilla, G. J.; Majidi, V.

    2005-01-01

    A method was developed to detect fingerprints using a technique known as micro-X-ray fluorescence. The traditional method of detecting fingerprints involves treating the sample with certain powders, liquids, or vapors to add color to the fingerprint so that it can be easily seen and photographed for forensic purposes. This is known as contrast enhancement, and a multitude of chemical processing methods have been developed in the past century to render fingerprints visible. However, fingerprints present on certain substances such as fibrous papers and textiles, wood, leather, plastic, adhesives, and human skin can sometimes be difficult to detect by contrast enhancement. Children's fingerprints are also difficult to detect due to the absence of sebum on their skin, and detection of prints left on certain colored backgrounds can sometimes be problematic. Micro-X-ray fluorescence (MXRF) was studied here as a method to detect fingerprints based on chemical elements present in fingerprint residue. For example, salts such as sodium chloride and potassium chloride excreted in sweat are sometimes present in detectable quantities in fingerprints. We demonstrated that MXRF can be used to detect this sodium, potassium, and chlorine from such salts. Furthermore, using MXRF, each of these elements (and many other elements if present) can be detected as a function of location on a surface, so we were able to 'see' a fingerprint because these salts are deposited mainly along the patterns present in a fingerprint (traditionally called friction ridges in forensic science). MXRF is not a panacea for detecting all fingerprints; some prints will not contain enough detectable material to be 'seen'; however, determining an effective means of coloring a fingerprint with traditional contrast enhancement methods can sometimes be an arduous process with limited success. Thus, MXRF offers a possible alternative for detecting fingerprints, and it does not require any additional chemical

  8. In vivo monitoring of toxic metals: assessment of neutron activation and x-ray fluorescence techniques

    SciTech Connect

    Ellis, K.J.

    1986-01-01

    To date, cadmium, lead, aluminum, and mercury have been measured in vivo in humans. The possibilities of monitoring other toxic metals have also been demonstrated, but no human studies have been performed. Neutron activation analysis appears to be most suitable for Cd and Al measurements, while x-ray fluorescence is ideally suited for measurement of lead in superficial bone. Filtered neutron beams and polarized x-ray sources are being developed which will improve in vivo detection limits. Even so, several of the current facilities are already suitable for use in epidemiological studies of selected populations with suspected long-term low-level ''environmental'' exposures. Evaluation and diagnosis of patients presenting with general clinical symptoms attributable to possible toxic metal exposure may be assisted by in vivo examination. Continued in vivo monitoring of industrial workers, especially follow-up measurements, will provide the first direct assessment of changes in body burden and a direct measure of the biological life-times of these metals in humans. 50 refs., 4 figs., 2 tabs.

  9. Total Reflection X-ray Fluorescence attachment module modified for analysis in vacuum

    NASA Astrophysics Data System (ADS)

    Wobrauschek, P.; Streli, C.; Kregsamer, P.; Meirer, F.; Jokubonis, C.; Markowicz, A.; Wegrzynek, D.; Chinea-Cano, E.

    2008-12-01

    Based on the design of the low cost Total Reflection X-Ray Fluorescence attachment module available since 1986 from Atominstitut (WOBRAUSCHEK-module) which can be attached to existing X-ray equipment, a new version was developed which allows the analysis of samples in vacuum. This design was in particular possible as the Peltier cooled light weight Silicon Drift Detector is following all adjustment procedures for total reflection as angle rotation and linear motion. The detector is mounted through a vacuum feed and O-ring tightening to the small vacuum chamber. The standard 30 mm round quartz, Si-wafer or Plexiglas reflectors are used to carry the samples. The reflectors are placed on the reference plane with the dried sample down looking facing in about 0.5 mm distance the up looking detector window. The reflectors are resting on 3 steel balls defining precisely the reference plane for the adjustment procedure. As the rotation axis of the module is in the plane of the reflector surface, angle dependent experiments can be made to distinguish between film and particulate type contamination of samples. Operating with a Mo anode at 50 kV and 40 mA with a closely attached multilayer monochromator and using a 10 mm 2 KETEK silicon drift detector with 8 μm Be window, a sensitivity of 70 cps/ng for Rb was measured and detection limits of 2 pg were obtained.

  10. Imaging metals in proteins by combining electrophoresis with rapid x-ray fluorescence mapping.

    SciTech Connect

    Finney, L.; Chishti, Y.; Khare, T.; Giometti, C.; Levina, A.; Lay, P. A.; Vogt, S.; Univ. of Sydney; Northwestern Univ.

    2010-01-01

    Growing evidence points toward a very dynamic role for metals in biology. This suggests that physiological circumstance may mandate metal ion redistribution among ligands. This work addresses a critical need for technology that detects, identifies, and measures the metal-containing components of complex biological matrixes. We describe a direct, user-friendly approach for identifying and quantifying metal?protein adducts in complex samples using native- or SDS-PAGE, blotting, and rapid synchrotron X-ray fluorescence mapping with micro-XANES (X-ray absorption near-edge structure) of entire blots. The identification and quantification of each metal bound to a protein spot has been demonstrated, and the technique has been applied in two exemplary cases. In the first, the speciation of the in vitro binding of exogenous chromium to blood serum proteins was influenced markedly by both the oxidation state of chromium exposed to the serum proteins and the treatment conditions, which is of relevance to the biochemistry of Cr dietary supplements. In the second case, in vivo changes in endogenous metal speciation were examined to probe the influence of oxygen depletion on iron speciation in Shewanella oneidensis.

  11. Toward chromium speciation in solids using wavelength dispersive X-ray fluorescence spectrometry Cr Kβ lines.

    PubMed

    Malherbe, J; Claverie, F

    2013-04-22

    The determination of chromium speciation in solid samples is critical for environmental and industrial purposes. Several analytical methods exist to perform such a determination either directly in solid state or liquid state after an extraction step, each of them having some limitations. In this study, the use of a high-resolution wavelength-dispersive X-ray fluorescence spectrometer to determine and quantify chromium species is investigated by looking at the differences in the Kβ transition profiles between Cr(0), Cr(III) and Cr(VI) compounds. Three different approaches were tested and compared to determine the Cr(VI) fraction of known mixtures: relative height and peak fitting using calibration mixtures, partial least square regression (PLS) of pure compounds, and principal component regression (PCR) of pure compounds. The accuracy of these methods was found to be about the same with an average relative error in the range of 15%. However, PLS and PCR can be easily implemented in an automated way contrary to peak fitting which can be sometimes perceived as analyst-dependant. Another advantage of using PLS and PCR is that information concerning the other oxidation states present in the sample can be retrieved. Finally, PLS and the peak height approach can be used up to 0.5% total chromium which make the XRF an alternative technique to X-ray induced photoelectron spectroscopy (XPS) for chromium speciation in solid state. PMID:23561904

  12. Laboratory Scale X-ray Fluorescence Tomography: Instrument Characterization and Application in Earth and Environmental Science.

    PubMed

    Laforce, Brecht; Vermeulen, Bram; Garrevoet, Jan; Vekemans, Bart; Van Hoorebeke, Luc; Janssen, Colin; Vincze, Laszlo

    2016-03-15

    A new laboratory scale X-ray fluorescence (XRF) imaging instrument, based on an X-ray microfocus tube equipped with a monocapillary optic, has been developed to perform XRF computed tomography experiments with both higher spatial resolution (20 μm) and a better energy resolution (130 eV @Mn-K(α)) than has been achieved up-to-now. This instrument opens a new range of possible applications for XRF-CT. Next to the analytical characterization of the setup by using well-defined model/reference samples, demonstrating its capabilities for tomographic imaging, the XRF-CT microprobe has been used to image the interior of an ecotoxicological model organism, Americamysis bahia. This had been exposed to elevated metal (Cu and Ni) concentrations. The technique allowed the visualization of the accumulation sites of copper, clearly indicating the affected organs, i.e. either the gastric system or the hepatopancreas. As another illustrative application, the scanner has been employed to investigate goethite spherules from the Cretaceous-Paleogene boundary, revealing the internal elemental distribution of these valuable distal ejecta layer particles. PMID:26891032

  13. Analysis of Russian kopecks (1877-1933) using x-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Cavness, B.; Williams, S.

    2013-04-01

    We have analyzed five Russian kopecks minted between the years of 1877 and 1933 using X-ray fluorescence (XRF) as part of an undergraduate research project. The intensities of the Cu K-shell X-rays were studied in order to compare the relative purities of the Cu used to mint the kopecks. The economic conditions under which the kopecks were minted are discussed, as well as impurities discovered during XRF analysis. In addition to XRF analysis, kopecks produced just before (1915) and after (1924) the October Revolution of 1917 were weighed in order to determine whether or not the Decree of February 22, 1924 was carried out. The legislation (enacted by the Central Executive Committee and the Council of the People's Commissaries) decreed that the proportions of pure Ag and Cu used in the minting of new coins should be the identical to those produced before the revolution and that the diameters and weights of the kopecks should also remain the same. The data from our experiments suggest that the legislation was successfully carried out.

  14. Lithographically-fabricated channel arrays for confocal x-ray fluorescence microscopy and XAFS

    NASA Astrophysics Data System (ADS)

    Woll, Arthur R.; Agyeman-Budu, David; Choudhury, Sanjukta; Coulthard, Ian; Finnefrock, Adam C.; Gordon, Robert; Hallin, Emil; Mass, Jennifer

    2014-03-01

    Confocal X-ray Fluorescence Microscopy (CXRF) employs overlapping focal regions of two x-ray optics—a condenser and collector—to directly probe a 3D volume. The minimum-achievable size of this probe volume is limited by the collector, for which polycapillaries are generally the optic of choice. Recently, we demonstrated an alternative collection optic for CXRF, consisting of an array of micron-scale collimating channels, etched in silicon, and arranged like spokes of a wheel directed towards a single source position. The optic, while successful, had a working distance of only 0.2 mm and exhibited relatively low total collection efficiency, limiting its practical application. Here, we describe a new design in which the collimating channels are formed by a staggered array of pillars whose side-walls taper away from the channel axis. This approach improves both collection efficiency and working distance, while maintaining excellent spatial resolution. We illustrate these improvements with confocal XRF data obtained at the Cornell High Energy Synchrotron Source (CHESS) and the Advanced Photon Source (APS) beamline 20-ID-B.

  15. Americium characterization by X-ray fluorescence and absorption spectroscopy in plutonium uranium mixed oxide

    NASA Astrophysics Data System (ADS)

    Degueldre, Claude; Cozzo, Cedric; Martin, Matthias; Grolimund, Daniel; Mieszczynski, Cyprian

    2013-06-01

    Plutonium uranium mixed oxide (MOX) fuels are currently used in nuclear reactors. The actinides in these fuels need to be analyzed after irradiation for assessing their behaviour with regard to their environment and the coolant. In this work the study of the atomic structure and next-neighbour environment of Am in the (Pu,U)O2 lattice in an irradiated (60 MW d kg-1) MOX sample was performed employing micro-X-ray fluorescence (µ-XRF) and micro-X-ray absorption fine structure (µ-XAFS) spectroscopy. The chemical bonds, valences and stoichiometry of Am (˜0.66 wt%) are determined from the experimental data gained for the irradiated fuel material examined in its peripheral zone (rim) of the fuel. In the irradiated sample Am builds up as Am3+ species within an [AmO8]13- coordination environment (e.g. >90%) and no (<10%) Am(IV) or (V) can be detected in the rim zone. The occurrence of americium dioxide is avoided by the redox buffering activity of the uranium dioxide matrix.

  16. The Viking X ray fluorescence experiment - Sampling strategies and laboratory simulations. [Mars soil sampling

    NASA Technical Reports Server (NTRS)

    Baird, A. K.; Castro, A. J.; Clark, B. C.; Toulmin, P., III; Rose, H., Jr.; Keil, K.; Gooding, J. L.

    1977-01-01

    Ten samples of Mars regolith material (six on Viking Lander 1 and four on Viking Lander 2) have been delivered to the X ray fluorescence spectrometers as of March 31, 1977. An additional six samples at least are planned for acquisition in the remaining Extended Mission (to January 1979) for each lander. All samples acquired are Martian fines from the near surface (less than 6-cm depth) of the landing sites except the latest on Viking Lander 1, which is fine material from the bottom of a trench dug to a depth of 25 cm. Several attempts on each lander to acquire fresh rock material (in pebble sizes) for analysis have yielded only cemented surface crustal material (duricrust). Laboratory simulation and experimentation are required both for mission planning of sampling and for interpretation of data returned from Mars. This paper is concerned with the rationale for sample site selections, surface sampler operations, and the supportive laboratory studies needed to interpret X ray results from Mars.

  17. Digital x-ray processing electronics for fluorescence EXAFS and spectroscopy

    NASA Astrophysics Data System (ADS)

    Hubbard, B.; Warburton, W. K.; Zhou, C. Z.

    1996-09-01

    We have developed a digital x-ray processor (DXP) for x-ray fluorescence spectroscopy, implemented in a 4-channel CAMAC module, which accepts inputs of either polarity from reset or tail preamplifiers, and outputs one spectrum per channel. Digital trapezoidal shaping and efficient pileup rejection are implemented in dedicated logic, with programmable peaking times from 0.5 to 20 msec. The energy resolution is comparable to good analog units at equivalent peaking times. A maximum input count rate (ICR) of 500,000 cps per channel can be accomodated at a peaking time of 0.5 msec. A digital signal processor on each channel is used to collect the data, apply corrections, and update the spectrum. The capabilities of the DXP prototype at high rates was tested at SSRL. Using an Ortec single-element germanium detector, the resolution was seen to degrade somewhat with increasing ICR above 150,000 cps, due to effects that we are still investigating. Collaborating with Hewlett-Packard and SSRL, the DXP was also used with a Kevex Si(Li) detector for trace element detection on silicon wafers in comparison with Kevex readout electronics. At 4 msec peaking time, DXP's resolution was slightly worse (10-15 eV) due to some excess noise pickup, though the background levels in the spectra were essentially identical in the two systems and the DXP's maximum count rate was several times higher.

  18. A multi-channel monolithic Ge detector system for fluorescence x-ray absorption spectroscopy

    SciTech Connect

    Bucher, J.J.; Allen, P.G.; Edelstein, N.M.; Shuh, D.K.; Madden, N.W.; Cork, C.; Luke, P.; Pehl, D.; Malone, D.

    1995-03-01

    Construction and performance of a monolithic quad-pixel Ge detector for fluorescence x-ray absorption spectroscopy (XAS) at synchrotron radiation sources are described. The detector semiconductor element has an active surface area of 4.0 cm{sup 2} which is electrically separated into four 1.0 cm{sup 2} pixels, with little interfacial dead volume. Spatial response of the array shows that cross-talk between adjacent pixels is < 10% for 5.9 keV photons that fall within 0.5 mm of the pixel boundaries. The detector electronics system uses pre-amplifiers built at LBNL with commercial Tennelec Model TC 244 amplifiers. Using an {sup 55}Fe test source (MnK{sub {alpha}}, 5.9 keV), energy resolution of better than 200 eV is achieved with a 4 {mu}sec peaking time. At 0.5 {mu}sec peaking time, pulse pileup results in a 75% throughput efficiency for an incoming count rate of 100 kHz. Initial XAS fluoresncece measurements at the beamline 4 wiggler end stations at SSRL show that the detector system has several advantages over commercial x-ray spectrometers for low-concentration counting.

  19. Modeling of x-ray fluorescence using MCNPX and Geant4

    SciTech Connect

    Rajasingam, Akshayan; Hoover, Andrew S; Fensin, Michael L; Tobin, Stephen J

    2009-01-01

    X-Ray Fluorescence (XRF) is one of thirteen non-destructive assay techniques being researched for the purpose of quantifying the Pu mass in used fuel assemblies. The modeling portion of this research will be conducted with the MCNPX transport code. The research presented here was undertaken to test the capability of MCNPX so that it can be used to benchmark measurements made at the ORNL and to give confidence in the application of MCNPX as a predictive tool of the expected capability of XRF in the context of used fuel assemblies. The main focus of this paper is a code-to-code comparison between MCNPX and Geant4 code. Since XRF in used fuel is driven by photon emission and beta decay of fission fragments, both terms were independently researched. Simple cases and used fuel cases were modeled for both source terms. In order to prepare for benchmarking to experiments, it was necessary to determine the relative significance of the various fission fragments for producing X-rays.

  20. Deformulation of a solid pharmaceutical form using computed tomography and X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Oliveira Junior, J. M.; Balcão, V. M.; Vila, M. M. D. C.; Aranha, N.; Yoshida, V. M. H.; Chaud, M. V.; Mangine Filho, S.

    2015-07-01

    Deformulation of medicines is of undeniable importance, since it can be utilized both to unravel the chemical composition of the excipients integrating a pharmaceutical formulation of a specific medicine and as an important tool to conduct morphometric studies of the formulation under study. Such strategy may be utilized in analytical studies aiming at quantifying the components of reference drugs, or in the identification of putative counterfeit pharmaceuticals. Deformulation makes use of physicochemical analysis tools to characterize, from the chemical point of view, the components integrating medicine pharmaceutical formulations and from the physical point of view, the morphological part of the pharmaceutical formulation. The techniques of computer tomography (SkyScan 1174 - Bruker microCT) and X-ray fluorescence analyses (using an X-ray source with W-anode from Hammatsu Photonics and Silicon Drift detector from Amptek) were successfully used in performing a process of deformulation of a solid pharmaceutical formulation of tablets, utilized herein as a model medicine for controlled drug release. The analytical methods used in this work, proved their effectiveness for the main goal of this study, which aimed to characterize a pharmaceutical formulation via its deconstruction.

  1. 3D Imaging of Transition Metals in the Zebrafish Embryo by X-ray Fluorescence Microtomography

    PubMed Central

    Bourassa, Daisy; Gleber, Sophie-Charlotte; Vogt, Stefan; Yi, Hong; Will, Fabian; Richter, Heiko; Shin, Chong Hyun; Fahrni, Christoph J.

    2014-01-01

    Synchrotron X-ray fluorescence (SXRF) microtomography has emerged as a powerful technique for the 3D visualization of the elemental distribution in biological samples. The mechanical stability, both of the instrument and the specimen, is paramount when acquiring tomographic projection series. By combining the progressive lowering of temperature method (PLT) with femtosecond laser sectioning, we were able to embed, excise, and preserve a zebrafish embryo at 24 hours post fertilization in an X-ray compatible, transparent resin for tomographic elemental imaging. Based on a data set comprised of 60 projections, acquired with a step size of 2 μm during 100 hours of beam time, we reconstructed the 3D distribution of zinc, iron, and copper using the iterative maximum likelihood expectation maximization (MLEM) reconstruction algorithm. The volumetric elemental maps, which entail over 124 million individual voxels for each transition metal, revealed distinct elemental distributions that could be correlated with characteristic anatomical features at this stage of embryonic development. PMID:24992831

  2. Laboratory Scale X-ray Fluorescence Tomography: Instrument Characterization and Application in Earth and Environmental Science.

    PubMed

    Laforce, Brecht; Vermeulen, Bram; Garrevoet, Jan; Vekemans, Bart; Van Hoorebeke, Luc; Janssen, Colin; Vincze, Laszlo

    2016-03-15

    A new laboratory scale X-ray fluorescence (XRF) imaging instrument, based on an X-ray microfocus tube equipped with a monocapillary optic, has been developed to perform XRF computed tomography experiments with both higher spatial resolution (20 μm) and a better energy resolution (130 eV @Mn-K(α)) than has been achieved up-to-now. This instrument opens a new range of possible applications for XRF-CT. Next to the analytical characterization of the setup by using well-defined model/reference samples, demonstrating its capabilities for tomographic imaging, the XRF-CT microprobe has been used to image the interior of an ecotoxicological model organism, Americamysis bahia. This had been exposed to elevated metal (Cu and Ni) concentrations. The technique allowed the visualization of the accumulation sites of copper, clearly indicating the affected organs, i.e. either the gastric system or the hepatopancreas. As another illustrative application, the scanner has been employed to investigate goethite spherules from the Cretaceous-Paleogene boundary, revealing the internal elemental distribution of these valuable distal ejecta layer particles.

  3. Micro-x-ray fluorescence, micro-x-ray absorption spectroscopy, and micro-x-ray diffraction investigation of lead speciation after the addition of different phosphorus amendments to a smelter-contaminated soil.

    PubMed

    Baker, Lucas R; Pierzynski, Gary M; Hettiarachchi, Ganga M; Scheckel, Kirk G; Newville, Matthew

    2014-03-01

    The stabilization of Pb on additions of P to contaminated soils and mine spoil materials has been well documented. It is clear from the literature that different P sources result in different efficacies of Pb stabilization in the same contaminated material. We hypothesized that the differences in the efficacy of Pb stabilization in contaminated soils on fluid or granular P amendment addition is due to different P reaction processes in and around fertilizer granules and fluid droplets. We used a combination of several synchrotron-based techniques (i.e., spatially resolved micro-X-ray fluorescence, micro-X-ray absorption near-edge structure spectroscopy, and micro-X-ray diffraction) to speciate Pb at two incubation times in a smelter-contaminated soil on addition of several fluid and granular P amendments. The results indicated that the Pb phosphate mineral plumbogummite was an intermediate phase of pyromorphite formation. Additionally, all fluid and granular P sources were able to induce Pb phosphate formation, but fluid phosphoric acid (PA) was the most effective with time and distance from the treatment. Granular phosphate rock and triple super phosphate (TSP) amendments reacted to generate Pb phosphate minerals, with TSP being more effective at greater distances from the point of application. As a result, PA and TSP were the most effective P amendments at inducing Pb phosphate formation, but caution needs to be exercised when adding large amounts of soluble P to the environment.

  4. Characterization of AlInN/AlN/GaN FET structures using x-ray diffraction, x-ray reflectometry and grazing incidence x-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Lesnik, Andreas; Bläsing, Jürgen; Hennig, Jonas; Dadgar, Armin; Krost, Alois

    2014-09-01

    The structural parameters of AlInN/AlN/GaN high mobility field effect transistors (FETs) determine their electrical properties. The AlN-interlayer (spacer) thickness especially plays an important role to enhance the mobility and the density of the two dimensional electron gas (2DEG). However, structural characterization of this ultra-thin AlN-interlayer is ambiguous when only high resolution x-ray diffraction (HRXRD) and x-ray reflectometry (XRR) are taken into account. Here a combined layer analysis was performed using HRXRD, XRR and grazing incidence x-ray fluorescence (GIXRF) for the determination of the AlN-interlayer thickness. A sample series of AlInN/AlN/GaN FETs on Si(1 1 1) has been grown and analysed. The growth time of the AlN-interlayer was changed from 0 to 12 s and the AlInN barrier was grown nearly lattice matched to GaN with a nominal thickness of 5 nm. By the combination of HRXRD, XRR, GIXRF and simultaneous simulation of the data the determination of the spacer thickness was successfully performed.

  5. Optimizing the operation of a high resolution vertical Johann spectrometer using a high energy fluorescer x-ray source

    SciTech Connect

    Haugh, Michael; Stewart, Richard

    2010-10-15

    This paper describes the operation and testing for a vertical Johann spectrometer (VJS) operating in the 13 keV range. The spectrometer is designed to use thin curved mica crystals or thick germanium crystals. The VJS must have a resolution of E/{Delta}E=3000 or better to measure the Doppler broadening of highly ionized krypton and operate at a small x-ray angle in order to be used as a diagnostic in a laser plasma target chamber. The VJS was aligned, tested, and optimized using a fluorescer type high energy x-ray (HEX) source located at National Security Technologies (NSTec), LLC, in Livermore, CA. The HEX uses a 160 kV x-ray tube to excite fluorescence from various targets. Both rubidium and bismuth fluorescers were used for this effort. This presentation describes the NSTec HEX system and the methods used to optimize and characterize the VJS performance.

  6. Optimizing the Operation of a Vertical Johann Spectrometer Using a High Energy Fluorescer X-ray Source

    SciTech Connect

    Haugh, Michael; Stewart, Richard

    2010-10-01

    This paper describes the operation and testing for a Vertical Johann Spectrometer (VJS) operating in the 13 keV range. The spectrometer is designed to use thin curved mica crystals or thick germanium crystals. The VJS must have a resolution E/ΔE=3000 or better to measure Doppler broadening of highly ionized krypton and operate at a small X-ray angle in order to be used as a diagnostic in a laser plasma target chamber. The VJS was aligned, tested, and optimized using a fluorescer type high energy X-ray (HEX) source located at National Security Technologies, LLC (NSTec), in Livermore, California. The HEX uses a 160 kV X-ray tube to excite fluorescence from various targets. Both rubidium and bismuth fluorescers were used for this effort. This presentation describes the NSTec HEX system and the methods used to optimize and characterize the VJS performance.

  7. X-Ray Fluorescence to Determine Zn in Bolivian Children using Hair Samples

    NASA Astrophysics Data System (ADS)

    Tellería Narvaez, C. A.; Fernández Alcázar, S.; Barrientos Zamora, F. G.; Chungara Castro, J.; Luna Lauracia, I.; Mamani Tola, H.; Mita Peralta, E.; Muñoz Gosálvez, A. O.; Romero Bolaños, L. E.; Ramírez Ávila, G. M.

    2014-06-01

    As a first step in the evaluation of nutritional levels in Bolivian children (8-13 years-old), we carried out X-Ray Fluorescence measurements in hair samples of children belonging to different social classes and living either in rural areas or in cities. The aim of this study is to contribute to health policies tending to improve the global health of children and consequently avoid malnutrition. Our method intends to have maximum reliability and at the same time be as simple as possible from an experimental point of view. Additionally, we use this method to determine some other elements such as Fe, Cu, Pb, As and Hg, the latter three considered as contaminants that could be present in children living in areas which neighbor mines and industries. This work will be complemented by some biological and medical tests.

  8. Mapping metals in Parkinson's and normal brain using rapid-scanning x-ray fluorescence.

    PubMed

    Popescu, Bogdan F Gh; George, Martin J; Bergmann, Uwe; Garachtchenko, Alex V; Kelly, Michael E; McCrea, Richard P E; Lüning, Katharina; Devon, Richard M; George, Graham N; Hanson, Akela D; Harder, Sheri M; Chapman, L Dean; Pickering, Ingrid J; Nichol, Helen

    2009-02-01

    Rapid-scanning x-ray fluorescence (RS-XRF) is a synchrotron technology that maps multiple metals in tissues by employing unique hardware and software to increase scanning speed. RS-XRF was validated by mapping and quantifying iron, zinc and copper in brain slices from Parkinson's disease (PD) and unaffected subjects. Regions and structures in the brain were readily identified by their metal complement and each metal had a unique distribution. Many zinc-rich brain regions were low in iron and vice versa. The location and amount of iron in brain regions known to be affected in PD agreed with analyses using other methods. Sample preparation is simple and standard formalin-fixed autopsy slices are suitable. RS-XRF can simultaneously and non-destructively map and quantify multiple metals and holds great promise to reveal metal pathologies associated with PD and other neurodegenerative diseases as well as diseases of metal metabolism.

  9. Detection of visible and latent fingerprints using micro-X-ray fluorescence elemental imaging.

    PubMed

    Worley, Christopher G; Wiltshire, Sara S; Miller, Thomasin C; Havrilla, George J; Majidi, Vahid

    2006-01-01

    Using micro-X-ray fluorescence (MXRF), a novel means of detecting fingerprints was examined in which the prints were imaged based on their elemental composition. MXRF is a nondestructive technique. Although this method requires a priori knowledge about the approximate location of a print, it offers a new and complementary means for detecting fingerprints that are also left pristine for further analysis (including potential DNA extraction) or archiving purposes. Sebaceous fingerprints and those made after perspiring were detected based on elements such as potassium and chlorine present in the print residue. Unique prints were also detected including those containing lotion, saliva, banana, or sunscreen. This proof-of-concept study demonstrates the potential for visualizing fingerprints by MXRF on surfaces that can be problematic using current methods.

  10. Forensic classification of counterfeit banknote paper by X-ray fluorescence and multivariate statistical methods.

    PubMed

    Guo, Hongling; Yin, Baohua; Zhang, Jie; Quan, Yangke; Shi, Gaojun

    2016-09-01

    Counterfeiting of banknotes is a crime and seriously harmful to economy. Examination of the paper, ink and toners used to make counterfeit banknotes can provide useful information to classify and link different cases in which the suspects use the same raw materials. In this paper, 21 paper samples of counterfeit banknotes seized from 13 cases were analyzed by wavelength dispersive X-ray fluorescence. After measuring the elemental composition in paper semi-quantitatively, the normalized weight percentage data of 10 elements were processed by multivariate statistical methods of cluster analysis and principle component analysis. All these paper samples were mainly classified into 3 groups. Nine separate cases were successfully linked. It is demonstrated that elemental composition measured by XRF is a useful way to compare and classify papers used in different cases. PMID:27342345

  11. Performance of a Borehole X-ray Fluorescence Spectrometer for Planetary Exploration

    NASA Technical Reports Server (NTRS)

    Kelliher, Warren C.; Carlberg, Ingrid A.; Elam, W. T.; Willard-Schmoe, Ella

    2008-01-01

    We have designed and constructed a borehole X-ray Fluorescence Spectrometer (XRFS) as part of the Mars Subsurface Access program [1]. It can be used to determine the composition of the Mars regolith at various depths by insertion into a pre-drilled borehole. The primary requirements and performance metrics for the instrument are to obtain parts-per-million (ppm) lower limits of detection over a wide range of elements in the periodic table (Magnesium to Lead). Power consumption during data collection was also measured. The prototype instrument is complete and preliminary testing has been performed. Terrestrial soil Standard Reference Materials were used as the test samples. Detection limits were about 10 weight ppm for most elements, with light elements being higher, up to 1.4 weight percent for magnesium. Power consumption (excluding ground support components) was 12 watts.

  12. X-Ray Fluorescence to Determine Zn in Bolivian Children using Hair Samples

    SciTech Connect

    Tellería Narvaez, C.A.; Fernández Alcázar, S.; Barrientos Zamora, F.G.; Chungara Castro, J.; Luna Lauracia, I.; Mamani Tola, H.; Mita Peralta, E.; Muñoz Gosálvez, A.O.; Romero Bolaños, L.E.; Ramírez Ávila, G.M.

    2014-06-15

    As a first step in the evaluation of nutritional levels in Bolivian children (8–13 years-old), we carried out X-Ray Fluorescence measurements in hair samples of children belonging to different social classes and living either in rural areas or in cities. The aim of this study is to contribute to health policies tending to improve the global health of children and consequently avoid malnutrition. Our method intends to have maximum reliability and at the same time be as simple as possible from an experimental point of view. Additionally, we use this method to determine some other elements such as Fe, Cu, Pb, As and Hg, the latter three considered as contaminants that could be present in children living in areas which neighbor mines and industries. This work will be complemented by some biological and medical tests.

  13. Elemental Analysis of Variably Contaminated Cremains Using X-ray Fluorescence Spectrometry.

    PubMed

    Gilpin, Megan; Christensen, Angi M

    2015-07-01

    Analyzing and identifying skeletal remains becomes increasingly difficult when remains have been cremated, especially in cases where the cremated material may have been intentionally contaminated with nonskeletal material. This study examined the potential of X-ray fluorescence spectrometry (XRF) to detect the presence of nonskeletal contaminants in samples of cremains. Eleven samples of cremains were variably combined with concrete mix and analyzed using XRF. Photon counts of elements in each sample were analyzed, and the coefficient of determination (R(2)) using unweighted linear regression as a function of percent cremains was calculated. Results showed that with changes in the proportion of skeletal material and contaminant, there were significant (R(2) > 0.90) changes in detected levels of phosphorus, potassium, zinc, aluminum, and sulfur. The use of XRF is concluded to be a valid approach in the identification of the presence of nonskeletal material in potentially contaminated cremains.

  14. 100-OL-1 Operable Unit Field Portable X-Ray Fluorescence (XRF) Analyzer Pilot Study Plans

    SciTech Connect

    Bunn, Amoret L.; Fritz, Brad G.; Wellman, Dawn M.

    2014-07-15

    A pilot study is being conducted to support the approval of the Remedial Investigation/Feasibility Study (RI/FS) Work Plan to evaluate the 100-OL-1 Operable Unit (OU) pre-Hanford orchard lands. Based on comments received by the U.S. Environmental Protection Agency (EPA) and Washington State Department of Ecology, the pilot study will evaluate the use of field portable X-ray fluorescence (XRF) spectrometry measurements for evaluating lead and arsenic concentrations on the soil surface as an indicator of past use of lead arsenate pesticide residue in the OU. The work will be performed in the field during the summer of 2014, and assist in the planning for the characterization activities in the RI/FS.

  15. Evaluation on determination of iodine in coal by energy dispersive X-ray fluorescence

    USGS Publications Warehouse

    Wang, B.; Jackson, J.C.; Palmer, C.; Zheng, B.; Finkelman, R.B.

    2005-01-01

    A quick and inexpensive method of relative high iodine determination from coal samples was evaluated. Energy dispersive X-ray fluorescence (EDXRF) provided a detection limit of about 14 ppm (3 times of standard deviations of the blank sample), without any complex sample preparation. An analytical relative standard deviation of 16% was readily attainable for coal samples. Under optimum conditions, coal samples with iodine concentrations higher than 5 ppm can be determined using this EDXRF method. For the time being, due to the general iodine concentrations of coal samples lower than 5 ppm, except for some high iodine content coal, this method can not effectively been used for iodine determination. More work needed to meet the requirement of determination of iodine from coal samples for this method. Copyright ?? 2005 by The Geochemical Society of Japan.

  16. Determination of thorium in geological materials by x-ray fluorescence spectrometry after anion exchange extraction

    SciTech Connect

    Roelandts, I.

    1983-08-01

    The exchange capacity of the resin was determined to be 1 m equiv of Th/g dry resin. Synthetic calibration standards of thorium were prepared over a large concentration range, for use as an independent method of calibration. The advantages and disadvantages of direct x-ray fluorescence analysis are discussed. The lower limit of detection has been calculated according to Currie's convention and was found to be equal to 13 ..mu..g of Th/250 mg of resin, sufficient for the range of concentrations found in Th bearing minerals and ores. Results using Canadian syenite rocks and a suite of South African reference minerals show that the proposed method appears to be relatively precise and accurate for exploration geochemistry. 1 figure, 2 tables.

  17. Atomic layer deposition to prevent metal transfer from implants: An X-ray fluorescence study

    NASA Astrophysics Data System (ADS)

    Bilo, Fabjola; Borgese, Laura; Prost, Josef; Rauwolf, Mirjam; Turyanskaya, Anna; Wobrauschek, Peter; Kregsamer, Peter; Streli, Christina; Pazzaglia, Ugo; Depero, Laura E.

    2015-12-01

    We show that Atomic Layer Deposition is a suitable coating technique to prevent metal diffusion from medical implants. The metal distribution in animal bone tissue with inserted bare and coated Co-Cr alloys was evaluated by means of micro X-ray fluorescence mapping. In the uncoated implant, the migration of Co and Cr particles from the bare alloy in the biological tissues is observed just after one month and the number of particles significantly increases after two months. In contrast, no metal diffusion was detected in the implant coated with TiO2. Instead, a gradient distribution of the metals was found, from the alloy surface going into the tissue. No significant change was detected after two months of aging. As expected, the thicker is the TiO2 layer, the lower is the metal migration.

  18. Petrographic, mineralogic, and x-ray fluorescence analysis of lunar igneous-type rocks and spherules.

    PubMed

    Brown, G M; Emeleus, C H; Holland, J G; Phillips, R

    1970-01-30

    Three lunar rocks show almost identical mineralogy but grain sizes that vary from basaltic to gabbroic. Clinopyroxene is zoned from augite to subcalcic ferroaugite compositions and is accompanied by decrease in Cr, Al, and Ti. Plagioclase is zoned from 93 to 78 percent anorthite. Olivine (68 percent forsterite) is present in one rock and apatite is rare. Cristobalite, ilmenite with Ti-rich lamellae, ulvöspinel (often Cr-rich), troilite, and kamacite are low in trace elements. Glassy spherules are of basaltic or feldspathic (92 percent anorthite) composition but contain abundant iron spheres of taenite composition (13 percent Ni). Four rock analyses by x-ray fluorescence show affinity with terrestrial basalts but with anomalous amounts of Ti, Na, Cr, Zr, Y, Rb, Nb, Ni, Cu, and Zn.

  19. X-ray spectra of Hercules X-1. 1: Iron line fluorescence from a subrelativistic shell

    NASA Technical Reports Server (NTRS)

    Pravdo, S. H.; Becker, R. H.; Boldt, E. A.; Holt, S. S.; Serlemitsos, P. J.; Swank, J. H.

    1977-01-01

    The X-ray spectrum of Hercules X-1 was observed in the energy range 2-24 keV from August 29 to September 3, 1975. A broad iron line feature is observed in the normal high state spectrum. The line equivalent width is given along with its full-width-half-maximum energy. Iron line fluorescence from an opaque, cool shell of material at the Alfven surface provides the necessary luminosity in this feature. The line energy width can be due to Doppler broadening if the shell is forced to corotate with the pulsar at a radius 800 million cm. Implications of this model regarding physical conditions near Her X-1 are discussed.

  20. Elemental Analysis of Variably Contaminated Cremains Using X-ray Fluorescence Spectrometry.

    PubMed

    Gilpin, Megan; Christensen, Angi M

    2015-07-01

    Analyzing and identifying skeletal remains becomes increasingly difficult when remains have been cremated, especially in cases where the cremated material may have been intentionally contaminated with nonskeletal material. This study examined the potential of X-ray fluorescence spectrometry (XRF) to detect the presence of nonskeletal contaminants in samples of cremains. Eleven samples of cremains were variably combined with concrete mix and analyzed using XRF. Photon counts of elements in each sample were analyzed, and the coefficient of determination (R(2)) using unweighted linear regression as a function of percent cremains was calculated. Results showed that with changes in the proportion of skeletal material and contaminant, there were significant (R(2) > 0.90) changes in detected levels of phosphorus, potassium, zinc, aluminum, and sulfur. The use of XRF is concluded to be a valid approach in the identification of the presence of nonskeletal material in potentially contaminated cremains. PMID:25762496

  1. X-ray fluorescence analysis of wear metals in used lubricating oils

    NASA Technical Reports Server (NTRS)

    Maddox, W. E.; Kelliher, W. C.

    1986-01-01

    Used oils from several aircraft at NASA's Langley Research Center were analyzed over a three year period using X-ray fluorescence (XRF) and atomic emission spectrometry. The results of both analyses are presented and comparisons are made. Fe and Cu data for oil from four internal combustion engines are provided and XRF and atomic emission spectrometry measurements were found to be in perfect agreement. However, distributions were found in the case of oil from a jet aircraft engine whereby the latter method gave values for total iron concentration in the oil and did not distinguish between suspended particles and oil additives. XRF does not have these particle-size limitations; moreover, it is a faster process. It is concluded that XRF is the preferred method in the construction of a man-portable oil wear analysis instrument.

  2. Unique Properties of Thermally Tailored Copper: Magnetically Active Regions and Anomalous X-ray Fluorescence Emissions

    PubMed Central

    2009-01-01

    When high-purity copper (≥99.98%wt) is melted, held in its liquid state for a few hours with iterative thermal cycling, then allowed to resolidify, the ingot surface is found to have many small regions that are magnetically active. X-ray fluorescence analysis of these regions exhibit remarkably intense lines from “sensitized elements” (SE), including in part or fully the contiguous series V, Cr, Mn, Fe, and Co. The XRF emissions from SE are far more intense than expected from known impurity levels. Comparison with blanks and standards show that the thermal “tailoring” also introduces strongly enhanced SE emissions in samples taken from the interior of the copper ingots. For some magnetic regions, the location as well as the SE emissions, although persistent, vary irregularly with time. Also, for some regions extraordinarily intense “sensitized iron” (SFe) emissions occur, accompanied by drastic attenuation of Cu emissions. PMID:20037657

  3. Calcium and Phosphorus Detection Using Benchtop Versus Handheld X-ray Fluorescence Spectrometers.

    PubMed

    Kuzel, Aaron R; Christensen, Angi M; Marvin, Susan M

    2016-01-01

    Elemental analysis of calcium (Ca) and phosphorus (P) has been shown to be useful in differentiating skeletal and nonskeletal material. X-ray fluorescence spectrometry (XRF) is an attractive, nondestructive technique for forensic anthropologists, and the development of portable XRF instrumentation is promising for field applications. This study examines the performance of handheld XRF instrumentation operated in air compared to a traditional benchtop XRF device that has the ability to control the analysis atmosphere. Both instruments can be used to effectively distinguish skeletal from nonskeletal remains. However, as the measurement atmosphere affects detection levels for calcium and phosphorus, Ca/P ratios obtained from the instruments and analysis conditions were found to differ significantly, with analyses conducted in air showing significantly lower phosphorus detection. Consequently, comparison of Ca/P ratios to conclude skeletal versus nonskeletal origin must be based on data collected under similar analysis conditions.

  4. [Progress in application of microbeam X-ray fluorescence spectroscopy in forensic science].

    PubMed

    Su, Hui-Fang; Liu, Chao; Hu, Sun-Lin; Wang, Song-Cai; Sun, Li-Min; Huang, Wei; Zhang, Xiao-Ting; Li, Shuang-Lin

    2013-02-01

    Microbeam X-ray fluorescence (micro-XRF) spectrometry has been raised as an analytical technique of microbeam during the recent years. With its advantages of high sensitivity, small sample requirement, high testing accuracy and non-destruction, the technique is widely utilized in forensic science. This review bases on recent researches at home and abroad, describes its applications including identification of gunshot residue, visualization of fingerprints, discrimination of drug source, production process, and other material evidences of analysis in crime scene. Thanks to the advances in technology, intelligent and portable micro-XRF equipment has appeared to be applied. It is believed that it may be more popular and frequent in administration of forensic science in the near future.

  5. Determination of the implantation dose in silicon wafers by X-ray fluorescence analysis

    SciTech Connect

    Klockenkaemper, R.; Becker, M.; Bubert, H.; Burba, P. ); Palmetshofer, L. )

    1990-08-01

    The ion dose implanted in silicon wafers was determined by X-ray fluorescence analysis after the implantation process. As only near-surface layers below 1-{mu}m thickness were considered, the calibration could be carried out with external standards consisting of thin films of doped gelatine spread on pure wafers. Dose values for Cr and Co were determined between 4 {times} 10{sup 15} and 2 {times} 10{sup 17} atoms/cm{sup 2}, the detection limits being about 3 {times} 10{sup 14} atoms/cm{sup 2}. The results are precise and accurate apart from a residual scatter of less than 7%. This was confirmed by flame atomic absorption spectrometry after volatilization of the silicon matrix as SiF{sub 4}. It was found that ion-current measurements carried out during the implantation process can have considerable systematic errors.

  6. Direct elemental analysis of cancer cell lines by total reflection X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Szoboszlai, Norbert; Réti, Andrea; Budai, Barna; Szabó, Zsuzsa; Kralovánszky, Judit; Záray, Gyula

    2008-12-01

    The elemental content of Cu, Fe and Zn in two human adenocarcinoma cell lines was investigated by total reflection X-ray fluorescence (TXRF) spectrometry. Cancer cells were sedimented directly to the quartz plates using a modified cytospin slide holder setup. Special glass stands and caps were also constructed to hold the quartz plates with the cells during the vapour-phase microwave assisted digestion. The method was validated by analysis of certified reference materials. The signal-to-noise ratio was optimized by washing the cells with different solutions. The technique was applied to the determination of Cu, Fe and Zn content of HT-29 and HCA-7 colorectal adenocarcinoma cell lines. Dry mass of the centrifuged cells were determined and the elemental analysis data reported for the two cell lines were referred either to cell numbers, to the total protein content or to the dry mass.

  7. Bromine and bromide content in soils: Analytical approach from total reflection X-ray fluorescence spectrometry.

    PubMed

    Gallardo, Helena; Queralt, Ignasi; Tapias, Josefina; Candela, Lucila; Margui, Eva

    2016-08-01

    Monitoring total bromine and bromide concentrations in soils is significant in many environmental studies. Thus fast analytical methodologies that entail simple sample preparation and low-cost analyses are desired. In the present work, the possibilities and drawbacks of low-power total reflection X-ray fluorescence spectrometry (TXRF) for the determination of total bromine and bromide contents in soils were evaluated. The direct analysis of a solid suspension using 20 mg of fine ground soil (<63 μm) gave a 3.7 mg kg(-1) limit of detection for bromine which, in most cases, was suitable for monitoring total bromine content in soils (Br content range in soils = 5-40 mg kg(-1)). Information about bromide determination in soils is also possible by analyzing the Br content in water soil extracts. In this case, the TXRF analysis can be directly performed by depositing 10 μL of the internal standardized soil extract sample on a quartz glass reflector in a measuring time of 1500 s. The bromide limit of detection by this approach was 10 μg L(-1). Good agreement was obtained between the TXRF results for the total bromine and bromide determinations in soils and those obtained by other popular analytical techniques, e.g. energy dispersive X-ray fluorescence spectrometry (total bromine) and ionic chromatography (bromide). As a study case, the TXRF method was applied to study bromine accumulation in two agricultural soils fumigated with a methyl bromide pesticide and irrigated with regenerated waste water. PMID:27179429

  8. [Determination of major elements in superphosphate by X-ray fluorescence spectrometry].

    PubMed

    Rui, Yu-Kui; Li, He; Shen, Jian-Bo; Zhang, Fu-Suo

    2008-11-01

    Phosphate fertilizer is one of the most important fertilizers. The authors determined nine kinds of major elements in superphosphate, the most important phosphate fertilizer, by X-ray fluorescence spectrometry. The detection range of SiO2, Al2O3, TFe2O3, MnO, MgO, CaO, Na2O, K2O and P2O5 is 15.0%-90.0%, 0.20%-25.0%, 0.20%-25.0%, 0.01%-0.35%, 0.20%-40.0%, 0.10%-35.0%, 0.10%-7.50%, 0.05%-7.50% and 1.00%-100.00% respectively, and the precision of the method for SiO2, Al2O3, TFe2O3, MnO, MgO, CaO, Na2O, K2O and P2O5 range from 0.20% to 0.005%, so the method of X-ray fluorescence spectrometry is a fast and effectual method for detecting the composition of phosphate fertilizer. The contents of the above elements showed (1) the detected superphosphate content is 18.101% of P2O5, which is accordant to the labeled level (> or = 16%); (2) the detected superphosphate contains much SiO2, TFe2O3, MgO, CaO and K2O, which are necessary for plant growth and the content of which is 16.954%, 1.495%, 1.580%, 21.428% and 1.585% respectively. These data showed that phosphate fertilizer sometimes can supply some trace elements for plants, but we should eliminate the interference effect of these elements when we research the role of phosphorus; (3) superphosphate contains 3.225% of Al2O3, so the authors should attention to the aluminium poison when superphosphate is used chronically. PMID:19271522

  9. Bromine and bromide content in soils: Analytical approach from total reflection X-ray fluorescence spectrometry.

    PubMed

    Gallardo, Helena; Queralt, Ignasi; Tapias, Josefina; Candela, Lucila; Margui, Eva

    2016-08-01

    Monitoring total bromine and bromide concentrations in soils is significant in many environmental studies. Thus fast analytical methodologies that entail simple sample preparation and low-cost analyses are desired. In the present work, the possibilities and drawbacks of low-power total reflection X-ray fluorescence spectrometry (TXRF) for the determination of total bromine and bromide contents in soils were evaluated. The direct analysis of a solid suspension using 20 mg of fine ground soil (<63 μm) gave a 3.7 mg kg(-1) limit of detection for bromine which, in most cases, was suitable for monitoring total bromine content in soils (Br content range in soils = 5-40 mg kg(-1)). Information about bromide determination in soils is also possible by analyzing the Br content in water soil extracts. In this case, the TXRF analysis can be directly performed by depositing 10 μL of the internal standardized soil extract sample on a quartz glass reflector in a measuring time of 1500 s. The bromide limit of detection by this approach was 10 μg L(-1). Good agreement was obtained between the TXRF results for the total bromine and bromide determinations in soils and those obtained by other popular analytical techniques, e.g. energy dispersive X-ray fluorescence spectrometry (total bromine) and ionic chromatography (bromide). As a study case, the TXRF method was applied to study bromine accumulation in two agricultural soils fumigated with a methyl bromide pesticide and irrigated with regenerated waste water.

  10. Laboratory experiment of particle size effect in X-ray fluorescence: implication to remote XRF results

    NASA Astrophysics Data System (ADS)

    Okada, T.

    Laboratory experiments have been performed to show that microscopic roughness in the uppermost layer of planetary surface results in remarkable alteration of intensities and spectral profiles of X-ray fluorescence, especially at large phase angles. In our studies, surface roughness was directly measured by laser microscopy. The measured surface profiles were smoothed and approximated into a single cyclic function of rectangular shape model. For any shock-induced cracked powders of oxides and silicates, two parameters of wavelength, 2W, and depth, H, are expressed in similar way. Using this model, we numerically estimated intensities of X-ray fluorescence at any solar phase angle. Assuming the asteroid in chondritic composition and the solar activity in low-level flare, our calculation exhibits that increase of Fe/Si by 10 to 30% and Ca/Si by 5 to 10% might be observed for phase angle of 90 degree, which is the case with the NEAR/XRS observation. Samples with simplest composition were used such as alumina, quartz, or SiC, but experiments with powdered basalt have been also conducted to confirm the physical phenomenon by using more complicated or realistic material. Specimen of various size has been prepared from a single basalt rock, which is cracked and sieved into four groups: 1) D<45 m, 2) 45180 m. We also found the remarkable tendency of increase of XRF intensity ratio of heavier elements with increasing the phase angle and the surface roughness.

  11. High resolution X-ray fluorescence imaging for a microbeam radiation therapy treatment planning system

    NASA Astrophysics Data System (ADS)

    Chtcheprov, Pavel; Inscoe, Christina; Burk, Laurel; Ger, Rachel; Yuan, Hong; Lu, Jianping; Chang, Sha; Zhou, Otto

    2014-03-01

    Microbeam radiation therapy (MRT) uses an array of high-dose, narrow (~100 μm) beams separated by a fraction of a millimeter to treat various radio-resistant, deep-seated tumors. MRT has been shown to spare normal tissue up to 1000 Gy of entrance dose while still being highly tumoricidal. Current methods of tumor localization for our MRT treatments require MRI and X-ray imaging with subject motion and image registration that contribute to the measurement error. The purpose of this study is to develop a novel form of imaging to quickly and accurately assist in high resolution target positioning for MRT treatments using X-ray fluorescence (XRF). The key to this method is using the microbeam to both treat and image. High Z contrast media is injected into the phantom or blood pool of the subject prior to imaging. Using a collimated spectrum analyzer, the region of interest is scanned through the MRT beam and the fluorescence signal is recorded for each slice. The signal can be processed to show vascular differences in the tissue and isolate tumor regions. Using the radiation therapy source as the imaging source, repositioning and registration errors are eliminated. A phantom study showed that a spatial resolution of a fraction of microbeam width can be achieved by precision translation of the mouse stage. Preliminary results from an animal study showed accurate iodine profusion, confirmed by CT. The proposed image guidance method, using XRF to locate and ablate tumors, can be used as a fast and accurate MRT treatment planning system.

  12. Identifying microbial habitats in soil using quantum dots and x-ray fluorescence microtomography

    NASA Astrophysics Data System (ADS)

    O'Brien, S. L.; Whiteside, M. D.; Sholto-Douglas, D.; Dohnalkova, A.; Durall, D. M.; Gursoy, D.; Jones, M. D.; Kovarik, L.; Lai, B.; Roehrig, C.; Sullivan, S.; Vogt, S.; Kemner, K. M.

    2015-12-01

    The metabolic activities of soil microbes are the primary drivers of biogeochemical processes controlling the terrestrial carbon cycle, nutrient availability to plants, contaminant remediation, water quality, and other ecosystem services. However, we have a limited understanding of microbial metabolic processes such as nutrient uptake rates, substrate preferences, or how microbes and microbial metabolism are distributed throughout the three-dimensional pore network of the soil. Here we use a novel combination of imaging techniques with quantum dots (QDs, engineered semiconductor nanoparticles that produce size or composition-dependent fluorescence) to locate bacteria in the three-dimensional pore network of a soil aggregate. First, we show using confocal and aberration-corrected transmission electron microscopies that bacteria (Bacillus subtilis, Pseudomonas fluorescens, and Pseudomonas protogens) actively take up and internalize CdSe/ZnS core/shell QDs conjugated to biologically relevant substrates. Next, we show that cells bearing QDs can be identified using fluorescence imaging with hard x-rays at 2ID-D at the Advanced Photon Source (APS). Finally, we demonstrate that the Se constituent to the QDs can be used to label bacteria in three-dimensional tomographic reconstructions of natural soil at 0.5 nm spatial resolution using hard x-rays at 2ID-E at the APS. This is the first time soil bacteria have been imaged in the intact soil matrix at such high resolution. These results offer a new way to experimentally investigate basic bacterial ecology in situ, revealing constraints on microbial function in soil that will help improve connections between pore-scale and ecosystem-scale processes in models.

  13. Characterization of X-ray polycapillary optics by LiF crystal radiation detectors through confocal fluorescence microscopy

    NASA Astrophysics Data System (ADS)

    Bonfigli, Francesca; Hampai, Dariush; Dabagov, Sultan B.; Montereali, Rosa Maria

    2016-08-01

    Solid-state radiation imaging detectors based on photoluminescent colour centres in lithium fluoride (LiF) crystals have been successfully tested for both advanced 2D and 3D characterizations of X-ray polycapillary optics by a table-top laboratory system. Polycapillary optics can control X-ray beams propagation and allows obtaining quasi-parallel beam (half-lens) or focused beams (full-lens). The combination of a fine-focused micro X-ray tube and a polycapillary lens can provide the high intensity radiation fluxes that are necessary for high resolution X-ray imaging. In this paper we present novel results about advanced characterization of these complex optics by 2D as well as 3D confocal laser fluorescence microscopy of X-ray irradiated LiF crystal detectors. Two dimensional high spatial resolution images on a wide field of view of transmitted X-rays through a semi-lens and 3D direct inspection of the coloured volumes produced in LiF crystals by both focused and parallel X-ray beam transmitted by a full and a semi-lens, respectively, as well as their 3D reconstructions were obtained. The results show that the photoluminescent colour centres volume in LiF crystals combined with an optical sectioning reading system provide information about tomography of transmitted X-ray beams by policapillary optics in a single exposure process. For the first time, the use of LiF crystal plates as versatile radiation imaging luminescent detectors have been used to characterize the operation of polycapillary optics as X-ray lens, in focusing and parallel mode.

  14. [Energy-dispersive x-ray fluorescence spectrometry--a forensic chemistry method for determination of shooting distance].

    PubMed

    Havel, J

    2003-10-01

    The article follows up the experiences Energo-dispersive X-ray fluorescence spectrometry (EDXRF) as the forensic necrochemical method as the tool for detection of metals (gunshot residues--GSR) in connection with gunshot-wounds of persons--authors: dipl. Ing. J. Havel and dipl. Ing. K. Zelenka and Energo-dispersive X-ray fluorescence spectrometry (EDXRF) as the forensic method as the tool for identification of inlets (gunshot--entries) and outlets (gunshot--exits)--author: dipl. Ing. J. Havel.

  15. Determination of heavy metals in suspended waste water collected from Oued El Harrach Algiers River by Energy Dispersive X-Ray Fluorescence

    NASA Astrophysics Data System (ADS)

    Ouziane, S.; Amokrane, A.; Toumert, I.

    2013-12-01

    A preliminary study of the atmospheric pollution in the centre of Algiers is one of the important fields of applications in the environmental science. Nowadays, we need to evaluate the level of the contamination which has an unfavourable effect on physicochemical properties of soils and plants and namely also on human health. In the present work, water samples collected from Oued El-Harrach Algiers River, have been filtered in 0.45 μm Millipore filters to be analysed by Energy Dispersive X-Ray Fluorescence technique using 109Cd radioisotope source. Concentrations of the toxic elements like heavy metals are determined and compared with the published ones values by Yoshida [1] and those obtained using PIXE and NAA techniques [6].

  16. Application of a high-resolution x-ray fluorescence analyzer.

    SciTech Connect

    Adams, B. W.; Attenkofer, K.; Experimental Facilities Division

    2006-01-01

    We have developed a high resolution x-ray fluorescence analyzer based on the principle of active optics. It combines a resolution of ca. 5 eV with a tunability over several keV and a wide solid-angle coverage (ca. 2 by 5 degrees). To date, this analyzer has been used in near-edge spectroscopy of gallium in GaAs, and for the detection and chemical speciation of trace amounts platinum in soot from an diesel engine. The latter application illustrates the use of the analyzer to enhance the signal-to-background ratio in trace-element x-ray fluorescence analysis. The analyzer is shown schematically in Fig. 1. In it, a strip of silicon is bent by an axial force from two pushers at its ends, and eight correctors act from above to bring the shape of the bent crystal to approximate a logarithmic spiral. A more detailed description of the device, its underlying theory, and adjustment procedures may be found elsewhere. The sample consisted of soot collected from the exhaust of a diesel engine burning a fuel with a platinum-based additive that was tested for the purpose of facilitating clean combustion. The concentration of platinum in the soot was about 100 ppm, and the chemical speciation (oxidation state, dispersed or in the form of nanoparticles, etc.) was unknown. A small speck of this soot containing 10{sup 12} to 10{sup 13} atoms was placed into the x-ray beam of the 11-ID-D station of the APS. The incident photon energy was scanned over the Pt L{sub 3} edge, and the Pt L{sub {alpha}1} fluorescence was detected using two silicon drift detectors (Vortex), one directly and one with the analyzer. The purpose of the analyzer in this application was to enhance the energy resolution by a factor of about 50 (250 eV for the drift detector, 5 eV for the analyzer), and thus reduce the background of elastically or Compton-scattered photons, while keeping the fluorescent line. Whereas the detector with the analyzer recorded a clear signature of platinum in the form of an absorption

  17. Reconstruction of Elemental Distribution Images from Synchrotron Radiation X-Ray Fluorescence Spectra

    NASA Astrophysics Data System (ADS)

    Toque, Jay Arre; Ide-Ektessabi, Ari

    Synchrotron radiation X-ray fluorescence spectroscopy (SRXRF) is a powerful technique for studying trace elements in biological samples and other materials in general. Its features including capability to perform measurements in air and water, noncontact and nondestructive assay are superior to other elemental analysis techniques. In this study, a technique for reconstructing elemental distribution mapping of trace elements from spectral data was developed. The reconstruction was made possible by using the measured fluorescent signals to obtain local differences in elemental concentrations. The proposed technique features interpolation and background subtraction using matrix transformations of the spectral data to produce an enhanced distribution images. It is achieved by employing polychromatic or monochromatic color assignments proportional to the fluorescence intensities for displaying single-element or multiple-element distributions respectively. Some typical applications (i.e., macrophage and tissue surrounding an implant) were presented and the samples were imaged using the proposed method. The distribution images of the trace elements of the selected samples were used in conjunction with other analytical techniques to draw relevant observations, which cannot be achieved using conventional techniques such as metallic uptake and corresponding cellular response. The elemental distribution images produced from this study were found to have better quality compared to images produced using other analytical techniques (e.g., SIMS, PIXE, XPS, etc).

  18. Distribution and speciation of bromine in mammalian tissue and fluids by X-ray fluorescence imaging and X-ray absorption spectroscopy.

    PubMed

    Ceko, Melanie J; Hummitzsch, Katja; Hatzirodos, Nicholas; Bonner, Wendy; James, Simon A; Kirby, Jason K; Rodgers, Raymond J; Harris, Hugh H

    2015-05-01

    Bromine is one of the most abundant and ubiquitous trace elements in the biosphere and until recently had not been shown to perform any essential biological function in animals. A recent study demonstrated that bromine is required as a cofactor for peroxidasin-catalysed formation of sulfilimine crosslinks in Drosophila. In addition, bromine dietary deficiency is lethal in Drosophila, whereas bromine replenishment restores viability. The aim of this study was to examine the distribution and speciation of bromine in mammalian tissues and fluids to provide further insights into the role and function of this element in biological systems. In this study we used X-ray fluorescence (XRF) imaging and inductively coupled plasma-mass spectrometry (ICP-MS) to examine the distribution of bromine in bovine ovarian tissue samples, follicular fluid and aortic serum, as well as human whole blood and serum and X-ray absorption spectroscopy (XAS) to identify the chemical species of bromine in a range of mammalian tissue (bovine, ovine, porcine and murine), whole blood and serum samples (bovine, ovine, porcine, murine and human), and marine samples (salmon (Salmo salar), kingfish (Seriola lalandi) and Scleractinian coral). Bromine was found to be widely distributed across all tissues and fluids examined. In the bovine ovary in particular it was more concentrated in the sub-endothelial regions of arterioles. Statistical comparison of the near-edge region of the X-ray absorption spectra with a library of bromine standards led to the conclusion that the major form of bromine in all samples analysed was bromide.

  19. Distribution and speciation of bromine in mammalian tissue and fluids by X-ray fluorescence imaging and X-ray absorption spectroscopy.

    PubMed

    Ceko, Melanie J; Hummitzsch, Katja; Hatzirodos, Nicholas; Bonner, Wendy; James, Simon A; Kirby, Jason K; Rodgers, Raymond J; Harris, Hugh H

    2015-05-01

    Bromine is one of the most abundant and ubiquitous trace elements in the biosphere and until recently had not been shown to perform any essential biological function in animals. A recent study demonstrated that bromine is required as a cofactor for peroxidasin-catalysed formation of sulfilimine crosslinks in Drosophila. In addition, bromine dietary deficiency is lethal in Drosophila, whereas bromine replenishment restores viability. The aim of this study was to examine the distribution and speciation of bromine in mammalian tissues and fluids to provide further insights into the role and function of this element in biological systems. In this study we used X-ray fluorescence (XRF) imaging and inductively coupled plasma-mass spectrometry (ICP-MS) to examine the distribution of bromine in bovine ovarian tissue samples, follicular fluid and aortic serum, as well as human whole blood and serum and X-ray absorption spectroscopy (XAS) to identify the chemical species of bromine in a range of mammalian tissue (bovine, ovine, porcine and murine), whole blood and serum samples (bovine, ovine, porcine, murine and human), and marine samples (salmon (Salmo salar), kingfish (Seriola lalandi) and Scleractinian coral). Bromine was found to be widely distributed across all tissues and fluids examined. In the bovine ovary in particular it was more concentrated in the sub-endothelial regions of arterioles. Statistical comparison of the near-edge region of the X-ray absorption spectra with a library of bromine standards led to the conclusion that the major form of bromine in all samples analysed was bromide. PMID:25675086

  20. Gold nanoparticle cluster-plasmon-enhanced fluorescent silica core-shell nanoparticles for X-ray computed tomography-fluorescence dual-mode imaging of tumors.

    PubMed

    Hayashi, Koichiro; Nakamura, Michihiro; Miki, Hirokazu; Ozaki, Shuji; Abe, Masahiro; Matsumoto, Toshio; Ishimura, Kazunori

    2013-06-11

    Owing to the surface plasmon resonance-enhanced electromagnetic field, clustered gold nanoparticles-fluorescent silica core-shell nanoparticles became excited within the therapeutic window and fluoresced strongly in this window. The nanoparticles enabled tumor detection using fluorescence imaging and X-ray computed tomography.

  1. [Analysis and characterization of Belamcanda chinensis with space mutagenesis breeding by X-ray fluorescence analysis and X-ray diffraction].

    PubMed

    Guan, Ying; Ding, Xi-Feng; Wang, Wen-Jing; Guo, Xi-Hua; Zhu, Yan-Ying

    2008-02-01

    The contents of various elements in the fourth generation Belamcanda chinensis (L.) DC. with space mutagenesis breeding were analyzed and characterized. X-ray fluorescence spectrum analysis (XRF) and powder X-ray diffraction (PXRD) were applied jointly. It was found that the content of K element in the space flight mutagenesis increases 1.03 and 0.31 times, Mg enhances 1.44 and 0.06 times, but Al reduces 38.5% and 85.5% respectively compared to the contents in the ground group and the comparison group, while those of Ca, Mn and Fe enhance 0.95, 0.30 and 0.29 times respectively contrasted to the ground group. Besides, there was discovered the crystal of whewellite in the Belamcanda chinensis (L.) DC. and the content in the ground group is less than that of the outer space and the outer space group, which in turn is less than that of the comparison group. It is concluded that the contents of mineral elements indispensable to body in the space group are closer or superior to the comparison, group as compared to the ground group. In the present paper, a quick and simple appraising method is offered, which may be of great significance to the popularization of the planting outer space Chinese traditional medicine to filtrate more excellent breed and set up norm of quality appraisal.

  2. First use of portable system coupling X-ray diffraction and X-ray fluorescence for in-situ analysis of prehistoric rock art.

    PubMed

    Beck, L; Rousselière, H; Castaing, J; Duran, A; Lebon, M; Moignard, B; Plassard, F

    2014-11-01

    Study of prehistoric art is playing a major role in the knowledge of human evolution. Many scientific methods are involved in this investigation including chemical analysis of pigments present on artefacts or applied to cave walls. In the past decades, the characterization of coloured materials was carried on by taking small samples. This procedure had two main disadvantages: slight but existing damage of the paintings and limitation of the number of samples. Thanks to the advanced development of portable systems, in-situ analysis of pigment in cave can be now undertaken without fear for this fragile Cultural Heritage. For the first time, a portable system combining XRD and XRF was used in an underground and archaeological environment for prehistoric rock art studies. In-situ non-destructive analysis of black prehistoric drawings and determination of their composition and crystalline structure were successfully carried out. Original results on pigments used 13,000 years ago in the cave of Rouffignac (France) were obtained showing the use of two main manganese oxides: pyrolusite and romanechite. The capabilities of the portable XRD-XRF system have been demonstrated for the characterization of pigments as well as for the analysis of rock in a cave environment. This first in-situ experiment combining X-ray diffraction and X-ray fluorescence open up new horizons and can fundamentally change our approach of rock art studies.

  3. X-ray nanoprobes and diffraction-limited storage rings: opportunities and challenges of fluorescence tomography of biological specimens

    PubMed Central

    de Jonge, Martin D.; Ryan, Christopher G.; Jacobsen, Chris J.

    2014-01-01

    X-ray nanoprobes require coherent illumination to achieve optic-limited resolution, and so will benefit directly from diffraction-limited storage rings. Here, the example of high-resolution X-ray fluorescence tomography is focused on as one of the most voracious demanders of coherent photons, since the detected signal is only a small fraction of the incident flux. Alternative schemes are considered for beam delivery, sample scanning and detectors. One must consider as well the steps before and after the X-ray experiment: sample preparation and examination conditions, and analysis complexity due to minimum dose requirements and self-absorption. By understanding the requirements and opportunities for nanoscale fluorescence tomography, one gains insight into the R&D challenges in optics and instrumentation needed to fully exploit the source advances that diffraction-limited storage rings offer. PMID:25177992

  4. Immediate screening of lead exposure in the workplace using portable X-ray fluorescence

    PubMed Central

    Gorce, Jean-Philippe; Roff, Martin

    2016-01-01

    ABSTRACT The use of a portable X-ray fluorescence spectrometer (PXRF) equipped with a miniaturised X-ray tube producing a small 8 mm diameter X-ray beam required the validation of two new sampling protocols for the immediate screening of occupational lead exposure. First, lead in dust and fumes, collected by Institute of Occupational Medicine (IOM) inhalable samplers on 25 mm diameter membrane filters, is quantified using PXRF. To account for irregular dust deposition, the filters are rotated manually by quarter turns. Multiple PXRF readings are collected from the central region and from two locations in the outer region. The inner region is distinguishable from the outer region, but the two outer region locations are indistinguishable. High correlations (R2 > 0.99) are found between the PXRF results and historical results obtained using a reference method based on a laboratory wavelength-dispersive sequential XRF instrument (WDXRF) for lead loadings between 1–161 μg. The PXRF results from the outer regions of the filters show a bias of −13% with respect to the WDXRF. Once this bias is allowed for, 95% of all PXRF results lie within −28% and +38% of the WDXRF results. Neither instrument accounts for potential dust accumulation on the walls of the IOM sampler. Therefore, methods based on their use can only be considered semi-quantitative. Second, a protocol combining direct PXRF measurements on workplace surfaces with surface wipes is designed for immediate on-site quantification of removable surface lead residues. The quantification of such residues by this method is compared with subsequent off-site wet chemistry analysis of the surface wipes. The two methods show a good correlation (R2 ∼ 0.88). The ratio of the amount of removable residues determined by PXRF and wipe sampling is close to one with range 0.26–3.94. It is demonstrated that PXRF can be used as an effective tool for the immediate screening of occupational lead exposure. Although this

  5. Americium characterization by X-ray fluorescence and absorption spectroscopy in plutonium uranium mixed oxide

    SciTech Connect

    Degueldre, Claude Cozzo, Cedric; Martin, Matthias; Grolimund, Daniel; Mieszczynski, Cyprian

    2013-06-01

    Plutonium uranium mixed oxide (MOX) fuels are currently used in nuclear reactors. The actinides in these fuels need to be analyzed after irradiation for assessing their behaviour with regard to their environment and the coolant. In this work the study of the atomic structure and next-neighbour environment of Am in the (Pu,U)O₂ lattice in an irradiated (60 MW d kg⁻¹) MOX sample was performed employing micro-X-ray fluorescence (µ-XRF) and micro-X-ray absorption fine structure (µ-XAFS) spectroscopy. The chemical bonds, valences and stoichiometry of Am (~0.66 wt%) are determined from the experimental data gained for the irradiated fuel material examined in its peripheral zone (rim) of the fuel. In the irradiated sample Am builds up as Am³⁺ species within an [AmO₈]¹³⁻ coordination environment (e.g. >90%) and no (<10%) Am(IV) or (V) can be detected in the rim zone. The occurrence of americium dioxide is avoided by the redox buffering activity of the uranium dioxide matrix. - Graphical abstract: Americium LIII XAFS spectra recorded for the irradiated MOX sub-sample in the rim zone for a 300 μm×300 μm beam size area investigated over six scans of 4 h. The records remain constant during multi-scan. The analysis of the XAFS signal shows that Am is found as trivalent in the UO₂ matrix. This analytical work shall open the door of very challenging analysis (speciation of fission product and actinides) in irradiated nuclear fuels. - Highlights: • Americium was characterized by microX-ray absorption spectroscopy in irradiated MOX fuel. • The americium redox state as determined from XAS data of irradiated fuel material was Am(III). • In the sample, the Am³⁺ face an AmO₈¹³⁻coordination environment in the (Pu,U)O₂ matrix. • The americium dioxide is reduced by the uranium dioxide matrix.

  6. Immediate screening of lead exposure in the workplace using portable X-ray fluorescence.

    PubMed

    Gorce, Jean-Philippe; Roff, Martin

    2016-01-01

    The use of a portable X-ray fluorescence spectrometer (PXRF) equipped with a miniaturised X-ray tube producing a small 8 mm diameter X-ray beam required the validation of two new sampling protocols for the immediate screening of occupational lead exposure. First, lead in dust and fumes, collected by Institute of Occupational Medicine (IOM) inhalable samplers on 25 mm diameter membrane filters, is quantified using PXRF. To account for irregular dust deposition, the filters are rotated manually by quarter turns. Multiple PXRF readings are collected from the central region and from two locations in the outer region. The inner region is distinguishable from the outer region, but the two outer region locations are indistinguishable. High correlations (R(2) > 0.99) are found between the PXRF results and historical results obtained using a reference method based on a laboratory wavelength-dispersive sequential XRF instrument (WDXRF) for lead loadings between 1-161 μg. The PXRF results from the outer regions of the filters show a bias of -13% with respect to the WDXRF. Once this bias is allowed for, 95% of all PXRF results lie within -28% and +38% of the WDXRF results. Neither instrument accounts for potential dust accumulation on the walls of the IOM sampler. Therefore, methods based on their use can only be considered semi-quantitative. Second, a protocol combining direct PXRF measurements on workplace surfaces with surface wipes is designed for immediate on-site quantification of removable surface lead residues. The quantification of such residues by this method is compared with subsequent off-site wet chemistry analysis of the surface wipes. The two methods show a good correlation (R(2) ∼ 0.88). The ratio of the amount of removable residues determined by PXRF and wipe sampling is close to one with range 0.26-3.94. It is demonstrated that PXRF can be used as an effective tool for the immediate screening of occupational lead exposure. Although this article focused on

  7. X-Ray Fluorescence Solvent Detection at the Substrate-Adhesive Interface

    NASA Technical Reports Server (NTRS)

    Wurth, Laura; Evans, Kurt; Weber, Bart; Headrick, Sarah

    2005-01-01

    tag element can then be mapped by its characteristic x-ray emission using either x-ray fluorescence, or electron-beam energy-and wavelength-dispersive x-ray spectrometry. The direct mapping techniques avoid issues of different diffusion or migration rates of solvents and elemental tags, while the indirect techniques avoid spectral resolution issues in cases where solvents and substrates have adjacent or overlapping peaks. In this study, cross-section component indirect mapping is being evaluated as a method for measuring migration of d-limonene based solvents in glass-cloth phenolic composite (GCP) prior to and during subsequent bonding and epoxy adhesive cure.

  8. Immediate screening of lead exposure in the workplace using portable X-ray fluorescence.

    PubMed

    Gorce, Jean-Philippe; Roff, Martin

    2016-01-01

    The use of a portable X-ray fluorescence spectrometer (PXRF) equipped with a miniaturised X-ray tube producing a small 8 mm diameter X-ray beam required the validation of two new sampling protocols for the immediate screening of occupational lead exposure. First, lead in dust and fumes, collected by Institute of Occupational Medicine (IOM) inhalable samplers on 25 mm diameter membrane filters, is quantified using PXRF. To account for irregular dust deposition, the filters are rotated manually by quarter turns. Multiple PXRF readings are collected from the central region and from two locations in the outer region. The inner region is distinguishable from the outer region, but the two outer region locations are indistinguishable. High correlations (R(2) > 0.99) are found between the PXRF results and historical results obtained using a reference method based on a laboratory wavelength-dispersive sequential XRF instrument (WDXRF) for lead loadings between 1-161 μg. The PXRF results from the outer regions of the filters show a bias of -13% with respect to the WDXRF. Once this bias is allowed for, 95% of all PXRF results lie within -28% and +38% of the WDXRF results. Neither instrument accounts for potential dust accumulation on the walls of the IOM sampler. Therefore, methods based on their use can only be considered semi-quantitative. Second, a protocol combining direct PXRF measurements on workplace surfaces with surface wipes is designed for immediate on-site quantification of removable surface lead residues. The quantification of such residues by this method is compared with subsequent off-site wet chemistry analysis of the surface wipes. The two methods show a good correlation (R(2) ∼ 0.88). The ratio of the amount of removable residues determined by PXRF and wipe sampling is close to one with range 0.26-3.94. It is demonstrated that PXRF can be used as an effective tool for the immediate screening of occupational lead exposure. Although this article focused on

  9. Rapid and reliable diagnosis of Wilson disease using X-ray fluorescence.

    PubMed

    Kaščáková, Slávka; Kewish, Cameron M; Rouzière, Stéphan; Schmitt, Françoise; Sobesky, Rodolphe; Poupon, Joël; Sandt, Christophe; Francou, Bruno; Somogyi, Andrea; Samuel, Didier; Jacquemin, Emmanuel; Dubart-Kupperschmitt, Anne; Nguyen, Tuan Huy; Bazin, Dominique; Duclos-Vallée, Jean-Charles; Guettier, Catherine; Le Naour, François

    2016-07-01

    Wilson's disease (WD) is a rare autosomal recessive disease due to mutations of the gene encoding the copper-transporter ATP7B. The diagnosis is hampered by the variability of symptoms induced by copper accumulation, the inconstancy of the pathognomonic signs and the absence of a reliable diagnostic test. We investigated the diagnostic potential of X-ray fluorescence (XRF) that allows quantitative analysis of multiple elements. Studies were performed on animal models using Wistar rats (n = 10) and Long Evans Cinnamon (LEC) rats (n = 11), and on human samples including normal livers (n = 10), alcohol cirrhosis (n = 8), haemochromatosis (n = 10), cholestasis (n = 6) and WD (n = 22). XRF experiments were first performed using synchrotron radiation to address the elemental composition at the cellular level. High-resolution mapping of tissue sections allowed measurement of the intensity and the distribution of copper, iron and zinc while preserving the morphology. Investigations were further conducted using a laboratory X-ray source for irradiating whole pieces of tissue. The sensitivity of XRF was highlighted by the discrimination of LEC rats from wild type even under a regimen using copper deficient food. XRF on whole formalin-fixed paraffin embedded needle biopsies allowed profiling of the elements in a few minutes. The intensity of copper related to iron and zinc significantly discriminated WD from other genetic or chronic liver diseases with 97.6% specificity and 100% sensitivity. This study established a definite diagnosis of Wilson's disease based on XRF. This rapid and versatile method can be easily implemented in a clinical setting.

  10. Hard X-ray Fluorescence Measurements of Heteroepitaxial Solid Oxide Fuel Cell Cathode Materials

    SciTech Connect

    Davis, Jacob N.; Miara, Lincoln J.; Saraf, Laxmikant V.; Kaspar, Tiffany C.; Gopalan, Srikanth; Pal, Uday B.; Woicik, Joseph C.; Basu, Soumendra N.; Ludwig, Karl F.

    2012-12-01

    Commonly, SOFCs are operated at high temperatures (above 800°C). At these temperatures expensive housing is needed to contain an operating stack as well as coatings to contain the oxidation of the metallic interconnects. Lowering the temperature of an operating device would allow for more conventional materials to be used, thus lowering overall cost. Understanding the surface chemical states of cations in the surface of the SOFC cathode is vital to designing a system that will perform well at lower temperatures. The samples studied were grown by pulsed laser deposition (PLD) at the Environmental Molecular Sciences Laboratory (EMSL) at Pacific Northwest National Laboratory (PNNL). 20% strontium doped lanthanum manganite (LSM-20) was grown on YSZ and NGO (neodymium gallate). The films on YSZ have a fiber texture. LSM-20 on NGO is heteroepitaxial. Lanthanum strontium cobalt ferrite (LSCF-6428) films were grown on LAO and YSZ with a GDC barrier layer. Total X-ray Reflection Fluorescence (TXRF) was used to depth profile the samples. In a typical experiment, the angle of the incident beam is varied though the critical angle. Below the critical angle, the x-ray decays as an evanescent wave and will only penetrate the top few nanometers. TXRF experiments done on LSM films have suggested strontium segregates to the surface and form strontium enriched nanoparticles (1). It should be pointed out that past studies have focused on 30% strontium A-site doping, but this project uses 20% strontium doped lanthanum manganite. XANES and EXAFS data were taken as a function of incoming angle to probe composition as a function of depth. XANES spectra can be difficult to analyze fully. For other materials density functional theory calculations compared to near edge measurements have been a good way to understand the 3d valence electrons (2).

  11. Analysis of arsenic pollution in groundwater aquifers by X-ray fluorescence.

    PubMed

    Sbarato, V M; Sánchez, H J

    2001-05-01

    The serious contamination of groundwater in the southeastern plain of the province of Córdoba (Argentina), a phenomenon mentioned in the literature for over 80 years, has given rise to this initial hydrologic study covering an area over 250 km2. This study analyzes a rural area near a little town called La Francía, and is motivated by the existence of an important pollution with arsenic in the first-aquifer groundwater of the region. This phenomenon has been mentioned for a long time and evidenced by the high incidence of diseases associated with this element in the local population. By means of the X-ray fluorescence (XRF) technique, and using an energy-dispersive spectrometer, 50 samples of groundwater of the rural zone of La Francia from about 100 m deep (second aquifer), were analyzed. The samples were excited with a 3 kW X-ray tube and measured using a reflecting geometry with 45 of incident and take-off directions. Preconcentration techniques for the preparation of the samples were employed in order to obtain an adequate signal-to-noise ratio. The As concentration in water was obtained using calibration curves and the internal standard method for quantification. A high percentage of the analyzed samples showed concentrations lesser than or equal to 0.05 mg l(-1). This value corresponds to the maximum pollutant level for humans. The maximum measured value reaches 3 mg l(-1) in samples collected in perforations of first-aquifer wells and in some second-aquifer isolated wells.

  12. Rapid and reliable diagnosis of Wilson disease using X-ray fluorescence.

    PubMed

    Kaščáková, Slávka; Kewish, Cameron M; Rouzière, Stéphan; Schmitt, Françoise; Sobesky, Rodolphe; Poupon, Joël; Sandt, Christophe; Francou, Bruno; Somogyi, Andrea; Samuel, Didier; Jacquemin, Emmanuel; Dubart-Kupperschmitt, Anne; Nguyen, Tuan Huy; Bazin, Dominique; Duclos-Vallée, Jean-Charles; Guettier, Catherine; Le Naour, François

    2016-07-01

    Wilson's disease (WD) is a rare autosomal recessive disease due to mutations of the gene encoding the copper-transporter ATP7B. The diagnosis is hampered by the variability of symptoms induced by copper accumulation, the inconstancy of the pathognomonic signs and the absence of a reliable diagnostic test. We investigated the diagnostic potential of X-ray fluorescence (XRF) that allows quantitative analysis of multiple elements. Studies were performed on animal models using Wistar rats (n = 10) and Long Evans Cinnamon (LEC) rats (n = 11), and on human samples including normal livers (n = 10), alcohol cirrhosis (n = 8), haemochromatosis (n = 10), cholestasis (n = 6) and WD (n = 22). XRF experiments were first performed using synchrotron radiation to address the elemental composition at the cellular level. High-resolution mapping of tissue sections allowed measurement of the intensity and the distribution of copper, iron and zinc while preserving the morphology. Investigations were further conducted using a laboratory X-ray source for irradiating whole pieces of tissue. The sensitivity of XRF was highlighted by the discrimination of LEC rats from wild type even under a regimen using copper deficient food. XRF on whole formalin-fixed paraffin embedded needle biopsies allowed profiling of the elements in a few minutes. The intensity of copper related to iron and zinc significantly discriminated WD from other genetic or chronic liver diseases with 97.6% specificity and 100% sensitivity. This study established a definite diagnosis of Wilson's disease based on XRF. This rapid and versatile method can be easily implemented in a clinical setting. PMID:27499926

  13. Novel handheld x-ray fluorescence spectrometer for routine testing for the presence of lead

    NASA Astrophysics Data System (ADS)

    Rensing, Noa M.; Tiernan, Timothy C.; Squillante, Michael R.

    2011-06-01

    RMD is developing a safe, inexpensive, and easy to operate lead detector for retailers and consumers that can reliably detect dangerous levels of lead in toys and other household products. Lead and its compounds have been rated as top chemicals that pose a great threat to human health. However, widespread testing for environmental lead is rarely undertaken until lead poisoning has already been diagnosed. The problem is not due to the accuracy or sensitivity of existing lead detection technology, but rather to the high expense, safety and licensing barriers of available test equipment. An inexpensive and easy to use lead detector would enable the identification of highly contaminated objects and areas and allow for timely and cost effective remediation. The military has similar needs for testing for lead and other heavy elements such as mercury, primarily in the decontamination of former military properties prior to their return to civilian use. RMD's research and development efforts are abased on advanced solid-state detectors combined with recently patented lead detection techniques to develop a consumer oriented lead detector that will be widely available and easy and inexpensive to use. These efforts will result in an instrument that offers: (1) high sensitivity, to identify objects containing dangerous amounts of lead, (2) low cost to encourage widespread testing by consumers and other end users and (3) convenient operation requiring no training or licensing. In contrast, current handheld x-ray fluorescence spectrometers either use a radioactive source requiring licensing and operating training, or use an electronic x-ray source that limits their sensitivity to surface lead.

  14. High energy x-ray diffraction/x-ray fluorescence spectroscopy for high-throughput analysis of composition spread thin films

    SciTech Connect

    Gregoire, John M.; Dale, Darren; Kazimirov, Alexander; DiSalvo, Francis J.; Dover, R. Bruce van

    2009-12-15

    High-throughput crystallography is an important tool in materials research, particularly for the rapid assessment of structure-property relationships. We present a technique for simultaneous acquisition of diffraction images and fluorescence spectra on a continuous composition spread thin film using a 60 keV x-ray source. Subsequent noninteractive data processing provides maps of the diffraction profiles, thin film fiber texture, and composition. Even for highly textured films, our diffraction technique provides detection of diffraction from each family of Bragg reflections, which affords direct comparison of the measured profiles with powder patterns of known phases. These techniques are important for high throughput combinatorial studies as they provide structure and composition maps which may be correlated with performance trends within an inorganic library.

  15. X-ray fluorescence analysis (XFA) of thyroidal iodine content (TIC) with an improved measuring system.

    PubMed

    Reiners, C; Hänscheid, H; Lassmann, M; Tiemann, M; Kreissl, M; Rendl, J; Bier, D

    1998-01-01

    X-ray fluorescence analysis is based on the principal that the electron structure of stable iodine in the thyroid is excited by Americium-241 gamma rays to emit a characteristic fluorescence radiation which is proportional to the amount of iodine present in the gland. A stationary measuring system consisting of a 11.1 GBq Am-241 source and a high-purity Germanium detector with spectrum analyser has been improved by a PC guided method for sonographic definition of the measuring volume. The lower limit of detectibility of the system corresponds to 0.01 mg of Iodine per ml of thyroid volume; the in vivo precision given as coefficient of variation amounts to 15%. The thyroid is exposed with a radiation dose of 6 microSv per measurement. First studies with this improved system carried out in 50 female volunteers between 20 and 40 years of age with normal thyroid volumes resulted in a mean iodine concentration of the thyroid of 0.665 +/- 0.304 mg/ml. The mean iodine excretion in urine was normal with 10.8 +/- 10.4 microg/dl. PMID:9865551

  16. Raman and fluorescence characteristics of resonant inelastic X-ray scattering from doped superconducting cuprates

    DOE PAGES

    Huang, H. Y.; Jia, C. J.; Chen, Z. Y.; Wohlfeld, K.; Moritz, B.; Devereaux, T. P.; Wu, W. B.; Okamoto, J.; Lee, W. S.; Hashimoto, M.; et al

    2016-01-22

    Measurements of spin excitations are essential for an understanding of spin-mediated pairing for superconductivity; and resonant inelastic X-ray scattering (RIXS) provides a considerable opportunity to probe high-energy spin excitations. However, whether RIXS correctly measures the collective spin excitations of doped superconducting cuprates remains under debate. Here we demonstrate distinct Raman- and fluorescence-like RIXS excitations of Bi1.5Pb0.6Sr1.54CaCu2O8+δ. Combining photon-energy and momentum dependent RIXS measurements with theoretical calculations using exact diagonalization provides conclusive evidence that the Raman-like RIXS excitations correspond to collective spin excitations, which are magnons in the undoped Mott insulators and evolve into paramagnons in doped superconducting compounds. In contrast,more » the fluorescence-like shifts are due primarily to the continuum of particle-hole excitations in the charge channel. Our results show that under the proper experimental conditions RIXS indeed can be used to probe paramagnons in doped high-Tc cuprate superconductors.« less

  17. Improved micro x-ray fluorescence spectrometer for light element analysis

    SciTech Connect

    Smolek, Stephan; Streli, Christina; Zoeger, Norbert; Wobrauschek, Peter

    2010-05-15

    Since most available micro x-ray fluorescence (micro-XRF) spectrometers operate in air, which does not allow the analysis of low-Z elements (Z{<=}14), a special micro-XRF spectrometer has been designed to extend the analytical range down to light elements (Z{>=}6). It offers improved excitation and detection conditions necessary for light element analysis. To eliminate absorption of the exciting and fluorescent radiation, the system operates under vacuum condition. Sample mapping is automated and controlled by specialized computer software developed for this spectrometer. Several different samples were measured to test and characterize the spectrometer. The spot size has been determined by scans across a 10 {mu}m Cu wire which resulted in a full width at half maximum of 31 {mu}m for Mo K{alpha} line (17.44 keV) and 44 {mu}m effective beam size for the Cu K edge and 71 {mu}m effective beam size for the Cu L edge. Lower limits of detection in the picogram range for each spot (or {mu}g/cm{sup 2}) were obtained by measuring various thin metal foils under different conditions. Furthermore, detection limits in the parts per million range were found measuring NIST621 standard reference material. Area scans of a microscopic laser print and NaF droplet were performed to show mapping capabilities.

  18. [Influence of the Experiment Energy Dispersive X-Ray Fluorescence Measurement of Uranium by Different Excitation Source].

    PubMed

    Xiong, Chao; Ge, Liang-quan; Liu, Duan; Zhang, Qing-xian; Gu, Yi; Luo, Yao-yao; Zhao, Jian-kun

    2016-03-01

    Aiming at the self-excitation effect on the interference of measurements which exist in the process of Energy dispersive X-ray fluorescence method for uranium measurement. To solve the problem of radioactive isotopes only used as excitation source in determination of uranium. Utilizing the micro X-ray tube to test Self-excitation effect to get a comparison of the results obtained by three different uranium ore samples--109 Cd, 241 Am and Mirco X-ray tube. The results showed that self-excitation effect produced the area measure of characteristic X-ray peak is less than 1% of active condition, also the interference of measurements can be negligible. Photoelectric effect cross-section excited by 109 Cd is higher, corresponding fluorescence yield is higher than excited by 241 Am as well due to characteristics X-ray energy of 109 Cd, 22.11 & 24.95 KeV adjacent to absorption edge energy of L(α), 21.75 KeV, based on the above, excitation efficiency by 109 Cd is higher than 241 Am; The fact that measurement error excited by 241 Am is significantly greater than by 109 Cd is mainly due to peak region overlap between L energy peaks of uranium and Scattering peak of 241 Am, 26.35 keV, These factors above caused the background of measured Spectrum higher; The error between the uranium content in ore samples which the X-ray tube as the excitation source and the chemical analysis results is within 10%. Conclusion: This paper come to the conclusion that the technical quality of uranium measurement used X-ray tube as excitation source is superior to that in radioactive source excitation mode. PMID:27400534

  19. [Influence of the Experiment Energy Dispersive X-Ray Fluorescence Measurement of Uranium by Different Excitation Source].

    PubMed

    Xiong, Chao; Ge, Liang-quan; Liu, Duan; Zhang, Qing-xian; Gu, Yi; Luo, Yao-yao; Zhao, Jian-kun

    2016-03-01

    Aiming at the self-excitation effect on the interference of measurements which exist in the process of Energy dispersive X-ray fluorescence method for uranium measurement. To solve the problem of radioactive isotopes only used as excitation source in determination of uranium. Utilizing the micro X-ray tube to test Self-excitation effect to get a comparison of the results obtained by three different uranium ore samples--109 Cd, 241 Am and Mirco X-ray tube. The results showed that self-excitation effect produced the area measure of characteristic X-ray peak is less than 1% of active condition, also the interference of measurements can be negligible. Photoelectric effect cross-section excited by 109 Cd is higher, corresponding fluorescence yield is higher than excited by 241 Am as well due to characteristics X-ray energy of 109 Cd, 22.11 & 24.95 KeV adjacent to absorption edge energy of L(α), 21.75 KeV, based on the above, excitation efficiency by 109 Cd is higher than 241 Am; The fact that measurement error excited by 241 Am is significantly greater than by 109 Cd is mainly due to peak region overlap between L energy peaks of uranium and Scattering peak of 241 Am, 26.35 keV, These factors above caused the background of measured Spectrum higher; The error between the uranium content in ore samples which the X-ray tube as the excitation source and the chemical analysis results is within 10%. Conclusion: This paper come to the conclusion that the technical quality of uranium measurement used X-ray tube as excitation source is superior to that in radioactive source excitation mode.

  20. Ultraviolet germicidal irradiation and its effects on elemental distributions in mouse embryonic fibroblast cells in x-ray fluorescence microanalysis.

    PubMed

    Jin, Qiaoling; Vogt, Stefan; Lai, Barry; Chen, Si; Finney, Lydia; Gleber, Sophie-Charlotte; Ward, Jesse; Deng, Junjing; Mak, Rachel; Moonier, Nena; Jacobsen, Chris

    2015-01-01

    Rapidly-frozen hydrated (cryopreserved) specimens combined with cryo-scanning x-ray fluorescence microscopy provide an ideal approach for investigating elemental distributions in biological cells and tissues. However, because cryopreservation does not deactivate potentially infectious agents associated with Risk Group 2 biological materials, one must be concerned with contamination of expensive and complicated cryogenic x-ray microscopes when working with such materials. We employed ultraviolet germicidal irradiation to decontaminate previously cryopreserved cells under liquid nitrogen, and then investigated its effects on elemental distributions under both frozen hydrated and freeze dried states with x-ray fluorescence microscopy. We show that the contents and distributions of most biologically important elements remain nearly unchanged when compared with non-ultraviolet-irradiated counterparts, even after multiple cycles of ultraviolet germicidal irradiation and cryogenic x-ray imaging. This provides a potential pathway for rendering Risk Group 2 biological materials safe for handling in multiuser cryogenic x-ray microscopes without affecting the fidelity of the results.

  1. Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS

    SciTech Connect

    Barrea, R.A.; Gore, D.; Kujala, N.; Karanfil, C.; Kozyrenko, S.; Heurich, R.; Vukonich, M.; Huang, R.; Paunesku, T.; Woloschak, G.; Irving, T.C.

    2010-07-23

    There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X-ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast-scanning high-flux X-ray microprobe, built around a recently commissioned pair of 200 mm-long Rh-coated silicon Kirkpatrick-Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 x 10{sup 12} photons s{sup -1} into a minimum focal spot size of {approx}3-5 {micro}m FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X-ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on-the-fly with minimal overhead time (<20 ms per pixel). Together, the high-flux X-ray microbeam and the rapid-scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X-ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples.

  2. Quantitative imaging of gold nanoparticle distribution in a tumor-bearing mouse using benchtop x-ray fluorescence computed tomography

    PubMed Central

    Manohar, Nivedh; Reynoso, Francisco J.; Diagaradjane, Parmeswaran; Krishnan, Sunil; Cho, Sang Hyun

    2016-01-01

    X-ray fluorescence computed tomography (XFCT) is a technique that can identify, quantify, and locate elements within objects by detecting x-ray fluorescence (characteristic x-rays) stimulated by an excitation source, typically derived from a synchrotron. However, the use of a synchrotron limits practicality and accessibility of XFCT for routine biomedical imaging applications. Therefore, we have developed the ability to perform XFCT on a benchtop setting with ordinary polychromatic x-ray sources. Here, we report our postmortem study that demonstrates the use of benchtop XFCT to accurately image the distribution of gold nanoparticles (GNPs) injected into a tumor-bearing mouse. The distribution of GNPs as determined by benchtop XFCT was validated using inductively coupled plasma mass spectrometry. This investigation shows drastically enhanced sensitivity and specificity of GNP detection and quantification with benchtop XFCT, up to two orders of magnitude better than conventional x-ray CT. The results also reaffirm the unique capabilities of benchtop XFCT for simultaneous determination of the spatial distribution and concentration of nonradioactive metallic probes, such as GNPs, within the context of small animal imaging. Overall, this investigation identifies a clear path toward in vivo molecular imaging using benchtop XFCT techniques in conjunction with GNPs and other metallic probes. PMID:26912068

  3. Ultraviolet germicidal irradiation and its effects on elemental distributions in mouse embryonic fibroblast cells in x-ray fluorescence microanalysis

    DOE PAGES

    Jin, Qiaoling; Vogt, Stefan; Lai, Barry; Chen, Si; Finney, Lydia; Gleber, Sophie-Charlotte; Ward, Jesse; Deng, Junjing; Mak, Rachel; Moonier, Nena; et al

    2015-02-23

    Rapidly-frozen hydrated (cryopreserved) specimens combined with cryo-scanning x-ray fluorescence microscopy provide an ideal approach for investigating elemental distributions in biological cells and tissues. However, because cryopreservation does not deactivate potentially infectious agents associated with Risk Group 2 biological materials, one must be concerned with contamination of expensive and complicated cryogenic x-ray microscopes when working with such materials. We employed ultraviolet germicidal irradiation to decontaminate previously cryopreserved cells under liquid nitrogen, and then investigated its effects on elemental distributions under both frozen hydrated and freeze dried states with x-ray fluorescence microscopy. We show that the contents and distributions of most biologicallymore » important elements remain nearly unchanged when compared with non-ultraviolet-irradiated counterparts, even after multiple cycles of ultraviolet germicidal irradiation and cryogenic x-ray imaging. This provides a potential pathway for rendering Risk Group 2 biological materials safe for handling in multiuser cryogenic x-ray microscopes without affecting the fidelity of the results.« less

  4. Ultraviolet germicidal irradiation and its effects on elemental distributions in mouse embryonic fibroblast cells in x-ray fluorescence microanalysis

    SciTech Connect

    Jin, Qiaoling; Vogt, Stefan; Lai, Barry; Chen, Si; Finney, Lydia; Gleber, Sophie-Charlotte; Ward, Jesse; Deng, Junjing; Mak, Rachel; Moonier, Nena; Jacobsen, Chris; Brody, James P.

    2015-02-23

    Rapidly-frozen hydrated (cryopreserved) specimens combined with cryo-scanning x-ray fluorescence microscopy provide an ideal approach for investigating elemental distributions in biological cells and tissues. However, because cryopreservation does not deactivate potentially infectious agents associated with Risk Group 2 biological materials, one must be concerned with contamination of expensive and complicated cryogenic x-ray microscopes when working with such materials. We employed ultraviolet germicidal irradiation to decontaminate previously cryopreserved cells under liquid nitrogen, and then investigated its effects on elemental distributions under both frozen hydrated and freeze dried states with x-ray fluorescence microscopy. We show that the contents and distributions of most biologically important elements remain nearly unchanged when compared with non-ultraviolet-irradiated counterparts, even after multiple cycles of ultraviolet germicidal irradiation and cryogenic x-ray imaging. This provides a potential pathway for rendering Risk Group 2 biological materials safe for handling in multiuser cryogenic x-ray microscopes without affecting the fidelity of the results.

  5. Ultraviolet germicidal irradiation and its effects on elemental distributions in mouse embryonic fibroblast cells in x-ray fluorescence microanalysis.

    PubMed

    Jin, Qiaoling; Vogt, Stefan; Lai, Barry; Chen, Si; Finney, Lydia; Gleber, Sophie-Charlotte; Ward, Jesse; Deng, Junjing; Mak, Rachel; Moonier, Nena; Jacobsen, Chris

    2015-01-01

    Rapidly-frozen hydrated (cryopreserved) specimens combined with cryo-scanning x-ray fluorescence microscopy provide an ideal approach for investigating elemental distributions in biological cells and tissues. However, because cryopreservation does not deactivate potentially infectious agents associated with Risk Group 2 biological materials, one must be concerned with contamination of expensive and complicated cryogenic x-ray microscopes when working with such materials. We employed ultraviolet germicidal irradiation to decontaminate previously cryopreserved cells under liquid nitrogen, and then investigated its effects on elemental distributions under both frozen hydrated and freeze dried states with x-ray fluorescence microscopy. We show that the contents and distributions of most biologically important elements remain nearly unchanged when compared with non-ultraviolet-irradiated counterparts, even after multiple cycles of ultraviolet germicidal irradiation and cryogenic x-ray imaging. This provides a potential pathway for rendering Risk Group 2 biological materials safe for handling in multiuser cryogenic x-ray microscopes without affecting the fidelity of the results. PMID:25706293

  6. Quantitative imaging of gold nanoparticle distribution in a tumor-bearing mouse using benchtop x-ray fluorescence computed tomography

    NASA Astrophysics Data System (ADS)

    Manohar, Nivedh; Reynoso, Francisco J.; Diagaradjane, Parmeswaran; Krishnan, Sunil; Cho, Sang Hyun

    2016-02-01

    X-ray fluorescence computed tomography (XFCT) is a technique that can identify, quantify, and locate elements within objects by detecting x-ray fluorescence (characteristic x-rays) stimulated by an excitation source, typically derived from a synchrotron. However, the use of a synchrotron limits practicality and accessibility of XFCT for routine biomedical imaging applications. Therefore, we have developed the ability to perform XFCT on a benchtop setting with ordinary polychromatic x-ray sources. Here, we report our postmortem study that demonstrates the use of benchtop XFCT to accurately image the distribution of gold nanoparticles (GNPs) injected into a tumor-bearing mouse. The distribution of GNPs as determined by benchtop XFCT was validated using inductively coupled plasma mass spectrometry. This investigation shows drastically enhanced sensitivity and specificity of GNP detection and quantification with benchtop XFCT, up to two orders of magnitude better than conventional x-ray CT. The results also reaffirm the unique capabilities of benchtop XFCT for simultaneous determination of the spatial distribution and concentration of nonradioactive metallic probes, such as GNPs, within the context of small animal imaging. Overall, this investigation identifies a clear path toward in vivo molecular imaging using benchtop XFCT techniques in conjunction with GNPs and other metallic probes.

  7. Ultraviolet Germicidal Irradiation and Its Effects on Elemental Distributions in Mouse Embryonic Fibroblast Cells in X-Ray Fluorescence Microanalysis

    PubMed Central

    Jin, Qiaoling; Vogt, Stefan; Lai, Barry; Chen, Si; Finney, Lydia; Gleber, Sophie-Charlotte; Ward, Jesse; Deng, Junjing; Mak, Rachel; Moonier, Nena; Jacobsen, Chris

    2015-01-01

    Rapidly-frozen hydrated (cryopreserved) specimens combined with cryo-scanning x-ray fluorescence microscopy provide an ideal approach for investigating elemental distributions in biological cells and tissues. However, because cryopreservation does not deactivate potentially infectious agents associated with Risk Group 2 biological materials, one must be concerned with contamination of expensive and complicated cryogenic x-ray microscopes when working with such materials. We employed ultraviolet germicidal irradiation to decontaminate previously cryopreserved cells under liquid nitrogen, and then investigated its effects on elemental distributions under both frozen hydrated and freeze dried states with x-ray fluorescence microscopy. We show that the contents and distributions of most biologically important elements remain nearly unchanged when compared with non-ultraviolet-irradiated counterparts, even after multiple cycles of ultraviolet germicidal irradiation and cryogenic x-ray imaging. This provides a potential pathway for rendering Risk Group 2 biological materials safe for handling in multiuser cryogenic x-ray microscopes without affecting the fidelity of the results. PMID:25706293

  8. FIELD MEASUREMENT TECHNOLOGY FOR MERCURY IN SOIL AND SEDIMENT NITON'S XLI/XLT 700 SERIES X-RAY FLUORESCENCE ANALYZER

    EPA Science Inventory

    NITON's XL-700 Series X-ray fluorescence analyzers were demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in May 2003 at the Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee. The purpose of the Demonstration...

  9. Determination of Gd and Sm contents in metallofullerenes on a total reflection X-ray fluorescence spectrometer with parallel beam

    NASA Astrophysics Data System (ADS)

    Tikhonova, A. E.; Kozlov, V. S.

    2014-01-01

    The contents of Gd and Sm have been determined quantitatively using the X-ray fluorescence analysis on a total reflection spectrometer with a parallel beam. It has been shown that the results can be used in developments of the technique for measuring the content of Gd metallofullerenes in powder samples several milligrams in weight and in liquid samples several microliters in volume.

  10. Relating Intercellular Variability in Nanoparticle Uptake with Biological Consequence: A Quantitative X-ray Fluorescence Study for Radiosensitization of Cells.

    PubMed

    Turnbull, Tyron; Douglass, Michael; Paterson, David; Bezak, Eva; Thierry, Benjamin; Kempson, Ivan

    2015-11-01

    Internalized gold nanoparticles were quantified in large numbers of individual prostate cancer cells using large area synchrotron X-ray fluorescence microscopy. Cells were also irradiated with a 6 MV linear accelerator to assess the biological consequence of radiosensitization with gold nanoparticles. A large degree of heterogeneity in nanoparticle uptake between cells resulted in influenced biological effect.

  11. Log spiral of revolution highly oriented pyrolytic graphite monochromator for fluorescence x-ray absorption edge fine structure

    SciTech Connect

    Pease, D. M.; Daniel, M.; Budnick, J. I.; Rhodes, T.; Hammes, M.; Potrepka, D. M.; Sills, K.; Nelson, C.; Heald, S. M.; Brewe, D. I.

    2000-09-01

    We have constructed an x-ray monochromator based on a log spiral of revolution covered with highly oriented pyrolytic graphite. Such a monochromator is used for obtaining x-ray absorption edge fine structure by the fluorescence method, and is particularly useful for measuring the fine structure of dilute element A in a concentrated matrix of element B, where B is to the left of A in the Periodic Table. Using the log spiral monochromator, we measure good Cr x-ray fine structure in an alloy of 1% Cr in a V matrix, whereas the corresponding spectrum is severely distorted by the V background if nonmonochromatized fluorescence is used. We also obtain excellent rejection of Mn fluorescence relative to Cr fluorescence in a Cr{sub 80}Mn{sub 20} alloy, and can tune the monochromator such that the entire Mn step height is significantly smaller than the Cr x-ray absorption edge fine structure oscillations for this system. (c) 2000 American Institute of Physics.

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - FIELD PORTABLE X-RAY FLUORESCENCE ANALYZER - METOREX, INC. X-MET 920-P AND 940

    EPA Science Inventory

    In April 1995, the U.S. Environmental Protection Agency (EPA) sponsored a demonstration of field portable X-ray fluorescence (FPXRF) analyzers. The primary objectives of this demonstration were (1) to determine how well FPXRF analyzers perform in comparison to standard reference...

  13. Synchrotron X-ray fluorescence studies of a bromine-labelled cyclic RGD peptide interacting with individual tumor cells.

    PubMed

    Sheridan, Erin J; Austin, Christopher J D; Aitken, Jade B; Vogt, Stefan; Jolliffe, Katrina A; Harris, Hugh H; Rendina, Louis M

    2013-03-01

    The first example of synchrotron X-ray fluorescence imaging of cultured mammalian cells in cyclic peptide research is reported. The study reports the first quantitative analysis of the incorporation of a bromine-labelled cyclic RGD peptide and its effects on the biodistribution of endogenous elements (for example, K and Cl) within individual tumor cells.

  14. Fingerprint methods for suspended sediment transport processes by using X-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Nakayama, K.; Beitia, C.; Ohtsu, N.; Yamasaki, S.; Yasuyuki, M.; Yamane, M.

    2014-12-01

    Suspended sediment (SS) can have significant impacts on ecological system, and high SS concentration can have significant impacts on human life. In the previous studies, radionuclide analysis has been applied to evaluate the production of SS in the river basins, which demonstrated that the surface soil erosion can be estimated by using radionuclide Pb-210ex. However, radionuclide analysis cannot indicate the relative amounts of SS transported from each individual sub-basin to the downstream end. Thus, X-ray Fluorescence Analysis (XRF Analysis) can be considered as an alternative method to radionuclide analysis because the XRF Analysis can measure 21 chemical compositions, Na2O, MgO, Al2O3, SiO2, P2O5, SO3, Cl, K2O, CaO, TiO2, Cr2O3, MnO, Fe2O3, Co2O3, NiO, CuO, ZnO, Rb2O, SrO, BaO, and Y2O3 by using X-ray Fluorescence Analyzer. In June of 2007, high turbidity, which is more than 10,000 (NTU), was measured in the Oromushi River basin of Hokkaido in Japan. Therefore, this study aims to clarify the mechanism of the transport of SS in the Oromushi River basin. We measured chemical compositions of soil with diameter less than 63 μm in the Oromushi River basin in order to pay attention to SS by using XRF. The Principal Component Analysis revealed that SiO2, Al2O3, Fe2O3, CaO and Na2O are the dominant chemical compositions. Although the predominant composition was the same in a river basin including the downstream end, significant differences were found in the pattern of chemical compositions. Therefore, by using the chemical compositions of SiO2, Al2O3, Fe2O3, CaO and Na2O, the Mixing Stable Isotope Analysis in R model (MixSIAR) based on Bayesian statistics was applied to estimate the transportation rate of SS from each sub-basin to the downstream end, which agreed with the field experiment results very well. As a result, spatial patterns of SS transportation rate are found to be strongly related to surface soil type.

  15. Probing the graphite band structure with resonant soft-x-ray fluorescence

    SciTech Connect

    Carlisle, J.A.; Shirley, E.L.; Hudson, E.A.

    1997-04-01

    Soft x-ray fluorescence (SXF) spectroscopy using synchrotron radiation offers several advantages over surface sensitive spectroscopies for probing the electronic structure of complex multi-elemental materials. Due to the long mean free path of photons in solids ({approximately}1000 {angstrom}), SXF is a bulk-sensitive probe. Also, since core levels are involved in absorption and emission, SXF is both element- and angular-momentum-selective. SXF measures the local partial density of states (DOS) projected onto each constituent element of the material. The chief limitation of SXF has been the low fluorescence yield for photon emission, particularly for light elements. However, third generation light sources, such as the Advanced Light Source (ALS), offer the high brightness that makes high-resolution SXF experiments practical. In the following the authors utilize this high brightness to demonstrate the capability of SXF to probe the band structure of a polycrystalline sample. In SXF, a valence emission spectrum results from transitions from valence band states to the core hole produced by the incident photons. In the non-resonant energy regime, the excitation energy is far above the core binding energy, and the absorption and emission events are uncoupled. The fluorescence spectrum resembles emission spectra acquired using energetic electrons, and is insensitive to the incident photon`s energy. In the resonant excitation energy regime, core electrons are excited by photons to unoccupied states just above the Fermi level (EF). The absorption and emission events are coupled, and this coupling manifests itself in several ways, depending in part on the localization of the empty electronic states in the material. Here the authors report spectral measurements from highly oriented pyrolytic graphite.

  16. Total reflection X-ray fluorescence trace mercury determination by trapping complexation: Application in advanced oxidation technologies

    NASA Astrophysics Data System (ADS)

    Custo, Graciela; Litter, Marta I.; Rodríguez, Diana; Vázquez, Cristina

    2006-11-01

    It is well known that Hg species cause high noxious effects on the health of living organisms even at very low levels (5 μg/L). Quantification of this element is an analytical challenge due to the peculiar physicochemical properties of all Hg species. The regulation of the maximal allowable Hg concentration led to search for sensitive methods for its determination. Total reflection X-ray fluorescence is a proved instrumental analytical tool for the determination of trace elements. In this work, the use of total reflection X-ray fluorescence for Hg quantification is investigated. However, experimental determination by total reflection X-ray fluorescence requires depositing a small volume of sample on the reflector and evaporation of the solvent until dryness to form a thin film. Because of volatilization of several Hg forms, a procedure to capture these volatile species in liquid samples by using complexing agents is proposed. Acetate, oxalic acid, ethylenediaminetetracetic acid and ammonium pyrrolidine-dithiocarbamate were assayed for trapping the analytes into the solution during the preparation of the sample and onto the reflector during total reflection X-ray fluorescence measurements. The proposed method was applied to evaluate Hg concentration during TiO 2-heterogeneous photocatalysis, one of the most known advanced oxidation technologies. Advanced oxidation technologies are processes for the treatment of effluents in waters and air that involve the generation of very active oxidative and reductive species. In heterogeneous photocatalysis, Hg is transformed to several species under ultraviolet illumination in the presence of titanium dioxide. Total reflection X-ray fluorescence was demonstrated to be applicable in following the extent of the heterogeneous photocatalysis reaction by determining non-transformed Hg in the remaining solution.

  17. Analytic 3D imaging of mammalian nucleus at nanoscale using coherent x-rays and optical fluorescence microscopy.

    PubMed

    Song, Changyong; Takagi, Masatoshi; Park, Jaehyun; Xu, Rui; Gallagher-Jones, Marcus; Imamoto, Naoko; Ishikawa, Tetsuya

    2014-09-01

    Despite the notable progress that has been made with nano-bio imaging probes, quantitative nanoscale imaging of multistructured specimens such as mammalian cells remains challenging due to their inherent structural complexity. Here, we successfully performed three-dimensional (3D) imaging of mammalian nuclei by combining coherent x-ray diffraction microscopy, explicitly visualizing nuclear substructures at several tens of nanometer resolution, and optical fluorescence microscopy, cross confirming the substructures with immunostaining. This demonstrates the successful application of coherent x-rays to obtain the 3D ultrastructure of mammalian nuclei and establishes a solid route to nanoscale imaging of complex specimens.

  18. A study of ancient pottery by means of X-ray fluorescence spectroscopy, multivariate statistics and mineralogical analysis.

    PubMed

    Papachristodoulou, Christina; Oikonomou, Artemios; Ioannides, Kostas; Gravani, Konstantina

    2006-07-28

    Energy-dispersive X-ray fluorescence spectroscopy was used to determine the composition of 64 potsherds from the Hellenistic settlement of Orraon, in northwestern Greece. Data classification by principal components analysis revealed four distinct groups of pottery, pointing to different local production practices rather than different provenance. The interpretation of statistical grouping was corroborated by a complementary X-ray diffraction analysis. Compositional and mineralogical data, combined with archaeological and materials' science criteria, allowed addressing various aspects of pottery making, such as selection of raw clays, tempers and firing conditions.

  19. 10 cm x 10 cm Single Gas Electron Multiplier (GEM) X-ray Fluorescence Detector for Dilute Elements

    NASA Astrophysics Data System (ADS)

    Shaban, E. H.; Siddons, D. P.; Seifu, D.

    2014-03-01

    We have built and tested a 10 cm × 10 cm single Gas Electron Multiplier (GEM) X-ray detector to probe dilute amounts of Fe in a prepared sample. The detector uses Argon/Carbon Dioxide (75/25) gas mixture flowing at a slow rate through a leak proof Plexi-glass enclosure held together by O-rings and screws. The Fluorescence X-ray emitted by the element under test is directed through a Mylar window into the drift region of the detector where abundant gas is flowing. The ionized electrons are separated, drifted into the high electric field of the GEM, and multiplied by impact ionization. The amplified negatively charged electrons are collected and further amplified by a Keithley amplifier to probe the absorption edge of the element under test using X-ray absorption spectroscopy technique. The results show that the GEM detector provided good results with less noise as compared with a Silicon drift detector (SDD).

  20. Accelerating K-Alpha Resonance Fluorescence Via Monochromatic X-Ray Beams And Comparison With LCLS-XFEL

    NASA Astrophysics Data System (ADS)

    Pradhan, Anil; Nahar, Sultana; Lim, Sara

    2015-05-01

    The presence of K-alpha resonances below the K-edge has been studied theoretically for high-Z (Fe, Pt, Au) and low-Z (Al, Ti, Cu) atoms, and recently observed experimentally at the LCLS x-ray free-electron laser facility in ``warm dense matter''. We present a mechanism for possible enhancement of the ``Auger cycle'' by employing a twin-beam monochromatic x-ray beams setup. We extend the theoretical formulation to construct a detailed radiative-cascade model using atomic rates computed using atomic structure and R-matrix codes. We also report preliminary results on K-alpha resonance fluorescence from experiments at the European Synchrotron Research Facility using a tungsten target. In addition, we describe a simple Broadband-to-Monchromatic (B2M) x-ray conversion device for potential use in monochromatic K-alpha imaging and other applications.

  1. Characterisation of mineralisation of bone and cartilage: X-ray diffraction and Ca and Sr K α X-ray fluorescence microscopy

    NASA Astrophysics Data System (ADS)

    Bradley, D. A.; Muthuvelu, P.; Ellis, R. E.; Green, E. M.; Attenburrow, D.; Barrett, R.; Arkill, K.; Colridge, D. B.; Winlove, C. P.

    2007-10-01

    Bone is a dynamic structure, constantly remodelling in response to changing mechanical and environmental factors. This is particularly evident in the mineral component encrusting the collagenous framework. The mineral is principally in the form of calcium apatite, but calcium can exchange with strontium, both during the cellular processes of mineralisation and resorption and by passive exchange with the deposited crystals. Mineralisation is generally characterized by densitometry, but because of the differences in absorption cross sections of calcium and strontium it can be misleading in studies of composition. In this work we have used X-ray diffraction to identify calcium and strontium apatite and X-ray fluorescence to quantify strontium and calcium distribution. With the beam characteristics available from synchrotron radiation, this has enabled us to obtain microscopic resolution on thin sections of bone and cartilage from the equine metacarpophalangeal joint. Two issues have been investigated; the first is the distribution of mineral in the bone-cartilage interface and within individual trabeculae. In trabecular bone the ratio of strontium to calcium concentration was typically 0.0035 ± 0.0020, and higher by a factor of ∼3 at the periphery than in the centre of a trabeculum (possibly reflecting the more rapid turnover of mineral in the surface layer). In the dense subchondral bone the ratio was similar, approximately doubling in the calcified cartilage. The second objective was to explore the changes in mineralisation associated with development of osteoarthrosis. We analysed lesions showing cartilage thinning and changes in the trabecular organization and density of the underlying bone. At the centre of the lesion the ratio of strontium to calcium was much lower than that in normal tissue, although the calcified cartilage still showed a higher ratio than the underlying bone. In the superficially normal tissue around the lesion the calcified cartilage

  2. Imaging of the intracellular topography of copper with a fluorescent sensor and by synchrotron x-ray fluorescence microscopy

    PubMed Central

    Yang, Liuchun; McRae, Reagan; Henary, Maged M.; Patel, Raxit; Lai, Barry; Vogt, Stefan; Fahrni, Christoph J.

    2005-01-01

    Copper is an essential micronutrient that plays a central role for a broad range of biological processes. Although there is compelling evidence that the intracellular milieu does not contain any free copper ions, the rapid kinetics of copper uptake and release suggests the presence of a labile intracellular copper pool. To elucidate the subcellular localization of this pool, we have synthesized and characterized a membrane-permeable, copper-selective fluorescent sensor (CTAP-1). Upon addition of Cu(I), the sensor exhibits a 4.6-fold emission enhancement and reaches a quantum yield of 14%. The sensor exhibits excellent selectivity toward Cu(I), and its emission response is not compromised by the presence of millimolar concentrations of Ca(II) or Mg(II) ions. Variable temperature dynamic NMR studies revealed a rapid Cu(I) self-exchange equilibrium with a low activation barrier of ΔG‡ = 44 kJ·mol–1 and kobs ∼ 105 s–1 at room temperature. Mouse fibroblast cells (3T3) incubated with the sensor produced a copper-dependent perinuclear staining pattern, which colocalizes with the subcellular locations of mitochondria and the Golgi apparatus. To evaluate and confirm the sensor's copper-selectivity, we determined the subcellular topography of copper by synchrotron-based x-ray fluorescence microscopy. Furthermore, microprobe x-ray absorption measurements at various subcellular locations showed a near-edge feature that is characteristic for low-coordinate monovalent copper but does not resemble the published spectra for metallothionein or glutathione. The presented data provide a coherent picture with strong evidence for a kinetically labile copper pool, which is predominantly localized in the mitochondria and the Golgi apparatus. PMID:16061820

  3. Imaging of the intracellular topography of copper with a fluorescent sensor and by synchrotron x-ray fluorescence microscopy.

    PubMed

    Yang, Liuchun; McRae, Reagan; Henary, Maged M; Patel, Raxit; Lai, Barry; Vogt, Stefan; Fahrni, Christoph J

    2005-08-01

    Copper is an essential micronutrient that plays a central role for a broad range of biological processes. Although there is compelling evidence that the intracellular milieu does not contain any free copper ions, the rapid kinetics of copper uptake and release suggests the presence of a labile intracellular copper pool. To elucidate the subcellular localization of this pool, we have synthesized and characterized a membrane-permeable, copper-selective fluorescent sensor (CTAP-1). Upon addition of Cu(I), the sensor exhibits a 4.6-fold emission enhancement and reaches a quantum yield of 14%. The sensor exhibits excellent selectivity toward Cu(I), and its emission response is not compromised by the presence of millimolar concentrations of Ca(II) or Mg(II) ions. Variable temperature dynamic NMR studies revealed a rapid Cu(I) self-exchange equilibrium with a low activation barrier of deltaG++ = 44 kJ.mol(-1) and k(obs) approximately 10(5) s(-1) at room temperature. Mouse fibroblast cells (3T3) incubated with the sensor produced a copper-dependent perinuclear staining pattern, which colocalizes with the subcellular locations of mitochondria and the Golgi apparatus. To evaluate and confirm the sensor's copper-selectivity, we determined the subcellular topography of copper by synchrotron-based x-ray fluorescence microscopy. Furthermore, microprobe x-ray absorption measurements at various subcellular locations showed a near-edge feature that is characteristic for low-coordinate monovalent copper but does not resemble the published spectra for metallothionein or glutathione. The presented data provide a coherent picture with strong evidence for a kinetically labile copper pool, which is predominantly localized in the mitochondria and the Golgi apparatus.

  4. Rainwater analysis by synchrotron radiation-total reflection X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    López, María L.; Ceppi, Sergio A.; Asar, María L.; Bürgesser, Rodrigo E.; Ávila, Eldo E.

    2015-11-01

    Total reflection X-ray fluorescence analysis excited with synchrotron radiation was used to quantify the elemental concentration of rainwater in Córdoba, Argentina. Standard solutions with gallium as internal standard were prepared for the calibration curves. Rainwater samples of 5 μl were added to an acrylic reflector, allowed to dry, and analyzed for 200 s measuring time. The elemental concentrations of As, Ca, Co, Cr, Cu, Fe, K, Mn, Ni, Pb, S, Sr, V, and Zn were determined. The electrical conductivity, pH, and elemental concentrations were compared to data previously reported for the soluble fraction of rainwater at different sites. A factor analysis was performed in order to determine the sources that contributed to the elemental concentration in rainwater. Anthropogenic sources were identified as traffic pollution, vehicular emissions, and metallurgical factories. The quality of rainwater was analyzed by comparing the concentrations of all the elements in rainwater samples with the WHO guideline values for drinking water. The results show the need to control the atmospheric emissions in order to preserve the quality of rainwater. SR-TXRF analysis of chemical composition of rainwater in Córdoba represents the very first contribution in the region to the knowledge of the concentration of trace metals in the soluble fraction of rainwater. These data are scarce, especially in the Southern Hemisphere.

  5. Using Synchrotron X-ray Fluorescence Microprobes in the Study of Metal Homeostasis in Plants

    SciTech Connect

    Punshon, T.; Guerinot, M; Lanzirotti, A

    2009-01-01

    Background and Aims: This Botanical Briefing reviews the application of synchrotron X-ray fluorescence (SXRF) microprobes to the plant sciences; how the technique has expanded our knowledge of metal(loid) homeostasis, and how it can be used in the future. Scope: The use of SXRF microspectroscopy and microtomography in research on metal homeostasis in plants is reviewed. The potential use of SXRF as part of the ionomics toolbox, where it is able to provide fundamental information on the way that plants control metal homeostasis, is recommended. Conclusions: SXRF is one of the few techniques capable of providing spatially resolved in-vivo metal abundance data on a sub-micrometre scale, without the need for chemical fixation, coating, drying or even sectioning of samples. This gives researchers the ability to uncover mechanisms of plant metal homeostasis that can potentially be obscured by the artefacts of sample preparation. Further, new generation synchrotrons with smaller beam sizes and more sensitive detection systems will allow for the imaging of metal distribution within single living plant cells. Even greater advances in our understanding of metal homeostasis in plants can be gained by overcoming some of the practical boundaries that exist in the use of SXRF analysis.

  6. Improving precision of X-ray fluorescence analysis of lanthanide mixtures using partial least squares regression

    NASA Astrophysics Data System (ADS)

    Kirsanov, Dmitry; Panchuk, Vitaly; Goydenko, Alexander; Khaydukova, Maria; Semenov, Valentin; Legin, Andrey

    2015-11-01

    This study addresses the problem of simultaneous quantitative analysis of six lanthanides (Ce, Pr, Nd, Sm, Eu, Gd) in mixed solutions by two different X-ray fluorescence techniques: energy-dispersive (EDX) and total reflection (TXRF). Concentration of each lanthanide was varied in the range 10- 6-10- 3 mol/L, low values being around the detection limit of the method. This resulted in XRF spectra with very poor signal to noise ratio and overlapping bands in case of EDX, while only the latter problem was observed for TXRF. It was shown that ordinary least squares approach in numerical calibration fails to provide for reasonable precision in quantification of individual lanthanides. Partial least squares (PLS) regression was able to circumvent spectral inferiorities and yielded adequate calibration models for both techniques with RMSEP (root mean squared error of prediction) values around 10- 5 mol/L. It was demonstrated that comparatively simple and inexpensive EDX method is capable of ensuring the similar precision to more sophisticated TXRF, when the spectra are treated by PLS.

  7. X-ray fluorescence spectroscopy and Monte Carlo characterization of a unique nuragic artifact (Sardinia, Italy)

    NASA Astrophysics Data System (ADS)

    Brunetti, Antonio; Depalmas, Anna; di Gennaro, Francesco; Serges, Alessandra; Schiavon, Nicola

    2016-07-01

    The chemical composition of a unique bronze artifact known as the "Cesta" ("Basket") belonging to the ancient Nuragic civilization of the Island of Sardinia, Italy has been analyzed by combining X-ray Fluorescence Spectroscopy (XRF) with Monte Carlo simulations using the XRMC code. The "Cesta" had been discovered probably in the XVIII century with the first graphic representation reported around 1761. In a later draft (dated 1764), the basket has been depicted as being carried upside-down on the shoulder of a large bronze warrior Barthélemy (1761), Pinza (1901), Winckelmann (1776) . The two pictorial representations differed only by the presence of handles in the most recent one. XRF measurements revealed that the handles of the object are composed by brass while the other parts are composed by bronze suggesting the handles as being a later addition to the original object. The artifact is covered at its surface by a fairly thick corrosion patina. In order to determine the bronze bulk composition without the need for removing the outer patina, the artifact has been modeled as a two layer object in Monte Carlo simulations.

  8. Uranium determination in seawater by total reflection X-ray fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Misra, N. L.; Dhara, S.; Mudher, K. D. Singh

    2006-11-01

    A study regarding uranium determination in seawater by total reflection X-ray fluorescence (TXRF) spectrometry is reported. Uranium, present in seawater in concentration of about 3.3 ng/mL, was selectively extracted in diethyl ether and determined by TXRF after its preconcentration by evaporation and subsequent dissolution in a small volume of 1.5% suprapure HNO 3. Yttrium was used as an internal standard. Before using diethyl ether for selective extraction of uranium from seawater, its extraction behavior for different elements was studied using a multielement standard solution having elemental concentrations in 5 ng/mL levels. It was observed that the extraction efficiency of diethyl ether for uranium was about 100% whereas for other elements it was negligible. The detection limit of TXRF method for uranium in seawater samples after pre-concentration step approaches to 67 pg/mL. The concentrations of uranium in seawater samples determined by TXRF are in good agreement with the values reported in the literature. The method shows a precision within 5% (1 σ). The study reveals that TXRF can be used as a fast analytical technique for the determination of uranium in seawater.

  9. Determination of element levels in human serum: Total reflection X-ray fluorescence applications

    NASA Astrophysics Data System (ADS)

    Majewska, U.; Łyżwa, P.; Łyżwa, K.; Banaś, D.; Kubala-Kukuś, A.; Wudarczyk-Moćko, J.; Stabrawa, I.; Braziewicz, J.; Pajek, M.; Antczak, G.; Borkowska, B.; Góźdź, S.

    2016-08-01

    Deficiency or excess of elements could disrupt proper functioning of the human body and could lead to several disorders. Determination of their concentrations in different biological human fluids and tissues should become a routine practice in medical treatment. Therefore the knowledge about appropriate element concentrations in human organism is required. The purpose of this study was to determine the concentration of several elements (P, S, Cl, K, Ca, Cr, Fe, Cu, Zn, Se, Br, Rb, Pb) in human serum and to define the reference values of element concentration. Samples of serum were obtained from 105 normal presumably healthy volunteers (66 women aged between 15 and 78 years old; 39 men aged between 15 and 77 years old). Analysis has been done for the whole studied population and for subgroups by sex and age. It is probably first so a wide study of elemental composition of serum performed in the case of Świętokrzyskie region. Total reflection X-ray fluorescence (TXRF) method was used to perform the elemental analysis. Spectrometer S2 Picofox (Bruker AXS Microanalysis GmbH) was used to identify and measure elemental composition of serum samples. Finally, 1st and 3rd quartiles were accepted as minimum and maximum values of concentration reference range.

  10. High temperature monitoring of silicon carbide ceramics by confocal energy dispersive X-ray fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Li, Fangzuo; Liu, Zhiguo; Sun, Tianxi

    2016-04-01

    In the present work, we presented an alternative method for monitoring of the oxidation situation of silicon carbide (SiC) ceramics at various high temperatures in air by measuring the Compton-to-Rayleigh intensity ratios (ICo/IRa) and effective atomic numbers (Zeff) of SiC ceramics with the confocal energy dispersive X-ray fluorescence (EDXRF) spectrometer. A calibration curve of the relationship between ICo/IRa and Zeff was established by using a set of 8 SiC calibration samples. The sensitivity of this approach is so high that it can be easily distinguished samples of Zeff differing from each other by only 0.01. The linear relationship between the variation of Zeff and the variations of contents of C, Si and O of SiC ceramics were found, and the corresponding calculation model of the relationship between the ΔZ and the ΔCC, ΔCSi, and ΔCO were established. The variation of contents of components of the tested SiC ceramics after oxidation at high temperature was quantitatively calculated based on the model. It was shown that the results of contents of carbon, silicon and oxygen obtained by this method were in good agreement with the results obtained by XPS, giving values of relative deviation less than 1%. It was concluded that the practicality of this proposed method for monitoring of the oxidation situation of SiC ceramics at high temperatures was acceptable.

  11. Diagnostic copper imaging of Menkes disease by synchrotron radiation-generated X-ray fluorescence analysis.

    PubMed

    Kinebuchi, Miyuki; Matsuura, Akihiro; Kiyono, Tohru; Nomura, Yumiko; Kimura, Sachiko

    2016-01-01

    Copper (Cu) is an indispensable metal for normal development and function of humans, especially in central nervous system (CNS). However, its redox activity requires accurate Cu transport system. ATP7A, a main Cu(2+) transporting-ATPase, is necessary to efflux Cu across the plasma membrane and synthesize cuproenzymes. Menkes disease (MD) is caused by mutations in ATP7A gene. Clinically, MD is Cu deficiency syndrome and is treated with Cu-histidine injections soon after definite diagnosis. But outcome of the most remains poor. To estimate the standard therapy, Cu distribution in the treated classic MD patients is analyzed by synchrotron-generated X-ray fluorescence technique (SR-XRF), which identifies and quantifies an individual atom up to at subcellular level of resolution with wide detection area. SR-XRF analysis newly reveals that Cu exists in spinal cord parenchyma and flows out via venous and lymph systems. By systemic analysis, excess Cu is detected in the proximal tubular cells of the kidney, the mucosal epithelial cells of the intestine, and the lymph and venous systems. The current study suggests that the standard therapy supply almost enough Cu for patient tissues. But given Cu passes through the tissues to venous and lymph systems, or accumulate in the cells responsible for Cu absorption. PMID:27629586

  12. Metal ions diffusion through polymeric matrices: A total reflection X-ray fluorescence study

    NASA Astrophysics Data System (ADS)

    Boeykens, S.; Caracciolo, N.; D'Angelo, M. V.; Vázquez, C.

    2006-11-01

    This work proposes the use of X-ray fluorescence with total reflection geometry to explore the metal ions transport in aqueous hydrophilic polymer solutions. It is centered in the study of polymer concentration influence on ion diffusion. This subject is relevant to various and diverse applications, such as drug controlled release, microbiologic corrosion protection and enhanced oil recovery. It is anticipated that diffusion is influenced by various factors in these systems, including those specific to the diffusing species, such as charge, shape, molecular size, and those related to the structural complexity of the matrix as well as any specific interaction between the diffusing species and the matrix. The diffusion of nitrate salts of Ba and Mn (same charge, different hydrodynamic radii) through water-swollen polymeric solutions and gels in the 0.01% to 1% concentration ranges was investigated. The measurements of the metal concentration were performed by TXRF analysis using the scattered radiation by the sample as internal standard. Results are discussed according to different physical models for solute diffusion in polymeric solutions.

  13. X-ray Fluorescence Spectroscopy Study of Coating Thickness and Base Metal Composition

    NASA Technical Reports Server (NTRS)

    Rolin, T. D.; Leszczuk, Y.

    2008-01-01

    For electrical, electronic, and electromechanical (EEE) parts to be approved for space use, they must be able to meet safety standards approved by NASA. A fast, reliable, and precise method is needed to make sure these standards are met. Many EEE parts are coated in gold (Au) and nickel (Ni), and the thickness coating is crucial to a part s performance. A nondestructive method that is efficient in measuring coating thickness is x-ray fluorescence (XRF) spectroscopy. The XRF spectrometer is a machine designed to measure layer thickness and composition of single or multilayered samples. By understanding the limitations in the collection of the data by this method, accurate composition and thickness measurements can be obtained for samples with Au and Ni coatings. To understand the limitations of data found, measurements were taken with the XRF spectrometer and compared to true values of standard reference materials (SRM) that were National Institute of Standards and Technology (NIST) traceable. For every sample, six different parameters were varied to understand measurement error: coating/substrate combination, number of layers, counting interval, collimator size, coating thickness, and test area location. Each measurement was taken in accordance with standards set by the American Society for Testing and Materials (ASTM) International Standard B 568.

  14. Micro energy-dispersive x-ray fluorescence spectrometry study of dentin coating with nanobiomaterials

    NASA Astrophysics Data System (ADS)

    Soares, Luís. Eduardo Silva; Nahorny, Sídnei; Marciano, Fernanda Roberta; Zanin, Hudson; Lobo, Anderson de Oliveira

    2015-06-01

    New biomaterials such as multi-walled carbon nanotubes oxide/graphene oxide (MWCNTO/GO), nanohydroxyapatite (nHAp) and combination of them together or not to acidulated phosphate fluoride gel (F) have been tested as protective coating before root dentin erosion. Fourteen bovine teeth were cleaned, polished, divided into two parts (n=28) and assigned to seven groups: (Control) - without previous surface treatment; F treatment; nHAp; MWCNTO/GO; F+nHAp; F+MWCNTO/GO and F+MWCNTO/GO/nHAp composites. Each sample had two sites of pre-treatments: acid etched area and an area without treatment. After the biomaterials application, the samples were submitted to six cycles (demineralization: orange juice, 10 min; remineralization: artificial saliva, 1 h). Micro energy-dispersive X-ray fluorescence spectrometry (μ-EDXRF) mapping area analyses were performed after erosive cycling on both sites (n=84). μ-EDXRF mappings showed that artificial saliva and MWCNTO/GO/nHAp/F composite treatments produced lower dentin demineralization than in the other groups. Exposed dentin tubules allowed better interaction of nanobiomaterials than in smear layer covered dentin. Association of fluoride with other biomaterials had a positive influence on acid etched dentin. MWCNTO/GO/nHAp/F composite treatment resulted in levels of demineralization similar to the control group.

  15. Optimal configuration for detection of gold nanoparticles in tumors using Kβ X-ray fluorescence line

    NASA Astrophysics Data System (ADS)

    Figueroa, R. G.; Santibañez, M.; Malano, F.; Valente, M.

    2015-12-01

    This study examines the increase in the capacity to detect gold nanoparticles in tumor tissue using X-rays from orthovoltage sources. The analyzed methodology considered aspects of geometry and composition in accordance with those required in real clinical treatment applications. The results show that a geometrical backscatter configuration, an incident spectral energy synthesized to optimize statistical parameters and adequate background subtraction allow for a significant increase in the signal to noise ratio (SNR) of the secondary Kβ lines. This increase is greater than those currently reported for traditional Kα lines. Furthermore, these conditions also produce an increase in detection sensitivity, less uncertainty in results and shorter exposure times. The proposed methodology was evaluated using XMI-MSIM software for the Monte Carlo simulation fluorescent response of each element. The simulation used tumors of 1-3 cm3, at a depth of 1-5 cm with a 0.1-1% gold nanoparticle concentration. The measurement time and the skin entrance dose by the methodology were considered for allows future quantitative surface scanning implementation.

  16. Total reflection X-ray fluorescence analysis of pollen as an indicator for atmospheric pollution*1

    NASA Astrophysics Data System (ADS)

    Pepponi, G.; Lazzeri, P.; Coghe, N.; Bersani, M.; Gottardini, E.; Cristofolini, F.; Clauser, G.; Torboli, A.

    2004-08-01

    The viability of pollen is affected by environmental pollution and its use as a bio-indicator is proposed. Such effects can be observed and quantified by biological tests. However, a more accurate identification of the agents affecting the viability is required in order to validate the biological assay for environmental monitoring. The chemical analysis of pollen is meant to ascertain the existence of a correlation between its reduced biological functions and the presence of pollutants. Moreover, such biological systems act as accumulators and allow the detection and quantification of species present in the environment at low concentrations. Total reflection X-ray fluorescence analysis (TXRF) has been chosen for the investigation due to its high sensitivity, multielement capability and wide dynamic range. Corylus avellana L. (hazel) pollen has been collected in areas with different anthropic impact in the province of Trento, Italy. For the TXRF measurements, a liquid sample is needed, especially if a quantitative analysis is required. In the present work, the analysis after a microwave digestion has been compared with the analysis of a suspension of the pollen samples. In both cases, an internal standard has been used for the quantification. The concentrations of 17 elements ranging from Al to Pb have been determined in 13 samples. Analysis of the suspensions showed to be comparable to that of digested samples in terms of spectral quality, but the latter preparation method gave better reproducibility. Sub-ppm lowest limits of detection were obtained for iron and heavier elements detected.

  17. Comparison of gold leaf thickness in Namban folding screens using X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Pessanha, Sofia; Madeira, Teresa I.; Manso, Marta; Guerra, Mauro; Le Gac, Agnès; Carvalho, Maria Luisa

    2014-09-01

    In this work, the thickness of the gold leaf applied in six Japanese folding screens is compared using a nondestructive approach. Four screens belonging to the Momoyama period (~1573-1603) and two screens belonging to the early Edo period (~1603-1868) were analyzed in situ using energy dispersive X-ray fluorescence, and the thickness of the applied gold leaf was evaluated using a methodology based on the attenuation of the different characteristic lines of gold in the gold leaf layer. Considering that the leaf may well not be made of pure gold, we established that, for the purpose of comparing the intensity ratios of the Au lines, layers made with gold leaf of high grade can be considered identical. The gold leaf applied in one of the screens from the Edo period was found to be thinner than the gold leaf applied in the other ones. This is consistent with the development of the beating technology to obtain ever more thin gold leafs.

  18. Evolution of thyroid /sup 127/I stores measured by X-ray fluorescence in subacute thyroiditis

    SciTech Connect

    Fragu, P.; Rougier, P.; Schlumberger, M.; Tubiana, M.

    1982-01-01

    Evaluation of the thyroid iodine content by x-ray fluorescence was performed in 13 patients throughout the course of subacute thyroiditis. In the initial hyperthyroid phase of the disease, the iodine stores of the thyroid were not completely depleted. The iodine content (6.5 +/- 3 mg) was about 2.5 times lower than normal values when thyroiditis had developed in a normal thyroid (10 patients); in 3 patients with goiter; it was elevated (29.6 +/- 6.7 mg) but was still within the normal range of euthyroid goitrous patients. After clinical remission, the iodine content of the gland increased only in two patients (+105% and +43% over the initial value, respectively). For the other patients, the iodine content decreased (from -5% to -100% of the initial value). Restoration of iodine stores occurred subsequently and appeared to be a slow and progressive phenomenon; in six patients the iodine content was still below normal values 12 months after clinical remission (6.6 +/- 1.6 mg). These data suggest that the course of subactue thyroiditis might be longer than would appear from the clinical data, the hormonal assays, or the radioactive thyroid uptake data.

  19. Green direct determination of mineral elements in artichokes by infrared spectroscopy and X-ray fluorescence.

    PubMed

    Mir-Marqués, Alba; Martínez-García, Maria; Garrigues, Salvador; Cervera, M Luisa; de la Guardia, Miguel

    2016-04-01

    Near infrared (NIR) and X-ray fluorescence (XRF) spectroscopy were investigated to predict the concentration of calcium, potassium, iron, magnesium, manganese and zinc in artichoke samples. Sixty artichokes were purchased from different Spanish areas (Benicarló, Valencia and Murcia). NIR and XRF spectra, combined with partial least squares (PLS) data treatment, were used to develop chemometric models for the prediction of mineral concentration. To obtain reference data, samples were mineralised and analysed by inductively coupled plasma optical emission spectrometry (ICP-OES). Coefficients of determination obtained for the regression between predicted values and reference ones for calcium, potassium, magnesium, iron, manganese and zinc were 0.61, 0.79, 0.53, 0.77, 0.54 and 0.60 for NIR and 0.96, 0.93, 0.80, 0.79, 0.76 and 0.90 for XRF, respectively. Both assayed methodologies, offer green alternatives to classical mineral analysis, but XRF provided the best results in order to be used as a quantitative screening method.

  20. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    NASA Astrophysics Data System (ADS)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2010-06-01

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO 3 and H 2O 2 (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different ( α = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 μg g - 1 . A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of "Citrus Leaves" and a blank were treated in the same way.

  1. [Research on the X-ray fluorescence spectrometry method to determine trace elements in kimberlite].

    PubMed

    Zhang, Lei; Yan, Chuan-wei; Lu, Yi

    2003-04-01

    It is very important to detect trace elements for kilmberlite. Through improving the working conditions of X-ray fluorescence spectrometer and optimizing the analytical conditions, the determination method of trace elements, such as Sc, Cr, Ni, Y, Nb, La, in kimberlite was worked out. The method has been successfully applied to the determination of trace elements in over 2 thousand samples of kimberlite from Liaoning province. The detection limits of the method were relatively low (the detection limit of Sc droped from 9.54 to 2.83 micrograms.g-1 and the detection limit of La droped from 21.68 micrograms.g-1 to 9.18 micrograms.g-1), i.e. 2.83, 2.15, 2.20, 1.17, 1.05 and 9.18 micrograms.g-1 for Sc, Cr, Ni, Y, Nb and La, respectively. The precision of the method was very high with 2.10%-7.09% of RSD (n = 20). Compared with ICP spectrometry this method is satisfactory. The method has proven to be simple and rapid with low cost and high efficiency.

  2. Diagnostic copper imaging of Menkes disease by synchrotron radiation-generated X-ray fluorescence analysis

    PubMed Central

    Kinebuchi, Miyuki; Matsuura, Akihiro; Kiyono, Tohru; Nomura, Yumiko; Kimura, Sachiko

    2016-01-01

    Copper (Cu) is an indispensable metal for normal development and function of humans, especially in central nervous system (CNS). However, its redox activity requires accurate Cu transport system. ATP7A, a main Cu2+ transporting-ATPase, is necessary to efflux Cu across the plasma membrane and synthesize cuproenzymes. Menkes disease (MD) is caused by mutations in ATP7A gene. Clinically, MD is Cu deficiency syndrome and is treated with Cu-histidine injections soon after definite diagnosis. But outcome of the most remains poor. To estimate the standard therapy, Cu distribution in the treated classic MD patients is analyzed by synchrotron-generated X-ray fluorescence technique (SR-XRF), which identifies and quantifies an individual atom up to at subcellular level of resolution with wide detection area. SR-XRF analysis newly reveals that Cu exists in spinal cord parenchyma and flows out via venous and lymph systems. By systemic analysis, excess Cu is detected in the proximal tubular cells of the kidney, the mucosal epithelial cells of the intestine, and the lymph and venous systems. The current study suggests that the standard therapy supply almost enough Cu for patient tissues. But given Cu passes through the tissues to venous and lymph systems, or accumulate in the cells responsible for Cu absorption. PMID:27629586

  3. Comparing Compositions of Modern Cast Bronze Sculptures: Optical Emission Spectroscopy Versus x-Ray Fluorescence Spectroscopy

    NASA Astrophysics Data System (ADS)

    Young, M. L.; Dunand, D. C.

    2015-07-01

    Bulk elemental compositions of 74 modern cast bronze sculptures from the collection at the Art Institute of Chicago, the Philadelphia Museum of Art, and the Rodin Museum (Philadelphia, PA) were determined using inductively coupled plasma-optical emission spectroscopy (ICP-OES) and a handheld x-ray fluorescence (XRF) spectrometer. The elemental compositions of the cast sculptures as measured previously by ICP-OES and presently by XRF are compared: A good match is found between the two methods for the base metal (Cu) and the two majority alloying elements (Zn and Sn). For both ICP-OES and XRF data, when the Zn composition is plotted versus the Sn composition, three discernable clusters are found that are related to the artist, foundry, casting date, and casting method; they consist of (A) high-zinc brass, (B) low-zinc, low-tin brass, and (C) low-zinc, tin bronze. Thus, our study confirms that the relatively fast, nondestructive XRF spectrometry can be used effectively over slower and invasive, but more accurate, ICP-OES to help determine a sculpture's artist, foundry, date of creation, date of casting, and casting method.

  4. Non-destructive investigation of a time capsule using neutron radiography and X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    MacDonald, B. L.; Vanderstelt, J.; O'Meara, J.; McNeill, F. E.

    2016-01-01

    Non-destructive analytical techniques are becoming increasingly important for the study of objects of cultural heritage interest. This study applied two techniques: X-ray fluorescence and neutron radiography, for the investigation of a capped, tubular metal object recovered from an urban construction site in Gore Park, Hamilton, Canada. The site is an urban park containing a World War I commemorative monument that underwent renovation and relocation. Historical documentation suggested that the object buried underneath the monument was a time capsule containing a paper document listing the names of 1800 Canadians who died during WWI. The purpose of this study was to assess the condition of the object, and to verify if it was what the historical records purported. XRF analysis was used to characterize the elemental composition of the metal artifact, while neutron radiography revealed that its contents were congruent with historical records and remained intact after being interred for 91 years. Results of this study demonstrate the value of non-destructive techniques for the analysis and preservation of cultural heritage.

  5. Algorithms for a hand-held miniature x-ray fluorescence analytical instrument

    SciTech Connect

    Elam, W.T.; Newman, D.; Ziemba, F.

    1998-12-31

    The purpose of this joint program was to provide technical assistance with the development of a Miniature X-ray Fluorescence (XRF) Analytical Instrument. This new XRF instrument is designed to overcome the weaknesses of spectrometers commercially available at the present time. Currently available XRF spectrometers (for a complete list see reference 1) convert spectral information to sample composition using the influence coefficients technique or the fundamental parameters method. They require either a standard sample with composition relatively close to the unknown or a detailed knowledge of the sample matrix. They also require a highly-trained operator and the results often depend on the capabilities of the operator. In addition, almost all existing field-portable, hand-held instruments use radioactive sources for excitation. Regulatory limits on such sources restrict them such that they can only provide relatively weak excitation. This limits all current hand-held XRF instruments to poor detection limits and/or long data collection times, in addition to the licensing requirements and disposal problems for radioactive sources. The new XRF instrument was developed jointly by Quantrad Sensor, Inc., the Naval Research Laboratory (NRL), and the Department of Energy (DOE). This report describes the analysis algorithms developed by NRL for the new instrument and the software which embodies them.

  6. Elemental analysis of mining wastes by energy dispersive X-ray fluorescence (EDXRF)

    NASA Astrophysics Data System (ADS)

    Gonzalez-Fernandez, O.; Queralt, I.; Carvalho, M. L.; Garcia, G.

    2007-08-01

    An energy dispersive X-ray fluorescence (EDXRF) tri-axial geometry experimental spectrometer has been employed to determine the concentrations of 13 different elements (K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr and Pb) in mine wastes from different depths of two mine tailings from the Cartagena-La Union (Spain) mining district. The elements were determined and quantified using the fundamental parameters method. The concentrations of Cr, Ni, Cu, Zn and Pb were compared to the values from the European and Spanish legislation to evaluate the environmental risk and to classify the wastes as inert wastes or as wastes that have to be control land-filled. The results obtained demonstrate that these wastes can be considered as inert for the considered elements, apart from the concentration levels of Zn and Pb. Whilst Zn slightly overpasses the regulatory levels, Pb mean value exceeds three to six times the value to be considered as Class I potential land-filling material.

  7. Evaluation of Field Portable X-Ray Fluorescence Performance for the Analysis of Ni in Soil.

    PubMed

    Du, Guo-dong; Lei, Mei; Zhou, Guang-dong; Chen, Tong-bin; Qiu, Rong-liang

    2015-03-01

    As a rapid, in-situ analysis method, Field portable X-ray fluorescence spectrometry (FP-XRF) can be widely applied in soil heavy metals analysis field. Whereas, some factors may affect FP-XRF performance and restrict the application. Studies have proved that FP-XRF has poorer performance when the concentration of target element is low, and soil moisture and particle size will affect FP-XRF performance. But few studies have been conducted in depth. This study took an example of Ni, demonstrated the relationship between Ni concentration and FP-XRF performance on accuracy and precision, and gave a critical value. Effects of soil moisture and particle size on accuracy and precision also had been compared. Results show that, FP-XRF performance is related to Ni concentration and the critical value is 400 mg x kg(-1). Relative standard deviation (RSD) and relative uncertainty decrease while the Ni concentration is below 400 mg x kg(-1), hence FP-XRF performance improves with increasing Ni concentration in this range; RSD and relative uncertainty change little while the Ni concentration is above 400 mg x kg(-1), hence FP-XRF performance does not have correlation with Ni concentration any more. For in-situ analysis, the relative uncertainty contributed by soil moisture is 3.77%, and the relative certainty contributed by particle size is 0.56%. Effect of soil moisture is evidently more serious than particle size both on accuracy and precision.

  8. Quantitative imaging of cell-permeable magnetic resonance contrast agents using x-ray fluorescence.

    PubMed

    Endres, Paul J; Macrenaris, Keith W; Vogt, Stefan; Allen, Matthew J; Meade, Thomas J

    2006-01-01

    The inability to transduce cellular membranes is a limitation of current magnetic resonance imaging probes used in biologic and clinical settings. This constraint confines contrast agents to extracellular and vascular regions of the body, drastically reducing their viability for investigating processes and cycles in developmental biology. Conversely, a contrast agent with the ability to permeate cell membranes could be used in visualizing cell patterning, cell fate mapping, gene therapy, and, eventually, noninvasive cancer diagnosis. Therefore, we describe the synthesis and quantitative imaging of four contrast agents with the capability to cross cell membranes in sufficient quantity for detection. Each agent is based on the conjugation of a Gd(III) chelator with a cellular transduction moiety. Specifically, we coupled Gd(III)-diethylenetriaminepentaacetic acid DTPA and Gd(III)-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid with an 8-amino acid polyarginine oligomer and an amphipathic stilbene molecule, 4-amino-4'-(N,N-dimethylamino)stilbene. The imaging modality that provided the best sensitivity and spatial resolution for direct detection of the contrast agents is synchrotron radiation x-ray fluorescence (SR-XRF). Unlike optical microscopy, SR-XRF provides two-dimensional images with resolution 10(3) better than (153)Gd gamma counting, without altering the agent by organic fluorophore conjugation. The transduction efficiency of the intracellular agents was evaluated by T(1) analysis and inductively coupled plasma mass spectrometry to determine the efficacy of each chelate-transporter combination. PMID:17150161

  9. Total reflection X-ray fluorescence as a tool for food screening

    NASA Astrophysics Data System (ADS)

    Borgese, Laura; Bilo, Fabjola; Dalipi, Rogerta; Bontempi, Elza; Depero, Laura E.

    2015-11-01

    This review provides a comprehensive overview of the applications of total reflection X-ray fluorescence (TXRF) in the field of food analysis. Elemental composition of food is of great importance, since food is the main source of essential, major and trace elements for animals and humans. Some potentially toxic elements, dangerous for human health may contaminate food, entering the food chain from the environment, processing, and storage. For this reason the elemental analysis of food is fundamental for safety assessment. Fast and sensitive analytical techniques, able to detect major and trace elements, are required as a result of the increasing demand on multi-elemental information and product screening. TXRF is suitable for elemental analysis of food, since it provides simultaneous multi-elemental identification in a wide dynamic range of concentrations. Several different matrices may be analyzed obtaining results with a good precision and accuracy. In this review, the most recent literature about the use of TXRF for the analysis of food is reported. The focus is placed on the applications within food quality monitoring of drinks, beverages, vegetables, fruits, cereals, animal derivatives and dietary supplements. Furthermore, this paper provides a critical outlook on the developments required to transfer these methods from research to the industrial and analytical laboratories contexts.

  10. Low-energy X-ray fluorescence microscopy opening new opportunities for bio-related research

    PubMed Central

    Kaulich, Burkhard; Gianoncelli, Alessandra; Beran, Alfred; Eichert, Diane; Kreft, Ivan; Pongrac, Paula; Regvar, Marjana; Vogel-Mikuš, Katarina; Kiskinova, Maya

    2009-01-01

    Biological systems are unique matter with very complex morphology and highly heterogeneous chemical composition dominated by light elements. Discriminating qualitatively at the sub-micrometer level the lateral distribution of constituent elements, and correlating it to the sub-cellular biological structure, continues to be a challenge. The low-energy X-ray fluorescence microspectroscopy, recently implemented in TwinMic scanning transmission mode, has opened up new opportunities for mapping the distribution of the light elements, complemented by morphology information provided by simultaneous acquisition of absorption and phase contrast images. The important new information that can be obtained in bio-related research domains is demonstrated by two pilot experiments with specimens of interest for marine biology and food science. They demonstrate the potential to yield important insights into the structural and compositional enrichment, distribution and correlation of essential trace elements in the lorica of Tintinnopsis radix, and the lateral distribution of trace nutrients in the seeds of wheat Triticum aestivum. PMID:19570794

  11. Green direct determination of mineral elements in artichokes by infrared spectroscopy and X-ray fluorescence.

    PubMed

    Mir-Marqués, Alba; Martínez-García, Maria; Garrigues, Salvador; Cervera, M Luisa; de la Guardia, Miguel

    2016-04-01

    Near infrared (NIR) and X-ray fluorescence (XRF) spectroscopy were investigated to predict the concentration of calcium, potassium, iron, magnesium, manganese and zinc in artichoke samples. Sixty artichokes were purchased from different Spanish areas (Benicarló, Valencia and Murcia). NIR and XRF spectra, combined with partial least squares (PLS) data treatment, were used to develop chemometric models for the prediction of mineral concentration. To obtain reference data, samples were mineralised and analysed by inductively coupled plasma optical emission spectrometry (ICP-OES). Coefficients of determination obtained for the regression between predicted values and reference ones for calcium, potassium, magnesium, iron, manganese and zinc were 0.61, 0.79, 0.53, 0.77, 0.54 and 0.60 for NIR and 0.96, 0.93, 0.80, 0.79, 0.76 and 0.90 for XRF, respectively. Both assayed methodologies, offer green alternatives to classical mineral analysis, but XRF provided the best results in order to be used as a quantitative screening method. PMID:26593585

  12. [Research on the X-ray fluorescence spectrometry method to determine trace elements in kimberlite].

    PubMed

    Zhang, Lei; Yan, Chuan-wei; Lu, Yi

    2003-04-01

    It is very important to detect trace elements for kilmberlite. Through improving the working conditions of X-ray fluorescence spectrometer and optimizing the analytical conditions, the determination method of trace elements, such as Sc, Cr, Ni, Y, Nb, La, in kimberlite was worked out. The method has been successfully applied to the determination of trace elements in over 2 thousand samples of kimberlite from Liaoning province. The detection limits of the method were relatively low (the detection limit of Sc droped from 9.54 to 2.83 micrograms.g-1 and the detection limit of La droped from 21.68 micrograms.g-1 to 9.18 micrograms.g-1), i.e. 2.83, 2.15, 2.20, 1.17, 1.05 and 9.18 micrograms.g-1 for Sc, Cr, Ni, Y, Nb and La, respectively. The precision of the method was very high with 2.10%-7.09% of RSD (n = 20). Compared with ICP spectrometry this method is satisfactory. The method has proven to be simple and rapid with low cost and high efficiency. PMID:12961906

  13. The use of total reflectance X-ray fluorescence (TXRF) for the determination of metals in the pharmaceutical industry.

    PubMed

    Antosz, Frederick J; Xiang, Yanqiao; Diaz, Angel R; Jensen, Andrew J

    2012-03-25

    The control of residual metals in active pharmaceutical ingredients (API's) and intermediates is critical because of their potential toxic effects. A variety of technologies are available to measure residual metals in pharmaceutical compounds including, AAS, ICP-AES, and ICP-MS. The newest technology is total reflectance X-ray fluorescence spectroscopy (TXRF) which uses primary X-rays to excite atoms which then emit secondary X-rays. The emitted X-rays are characteristic of the individual elements present, and the intensities of the emitted X-rays are proportional to the concentrations of the elements present in the sample. The benefits of TXRF are that it is essentially unaffected by matrix effects, is very sensitive (ppb's), requires small amounts of sample (5-10 mg), and requires very little sample preparation time. During this study, TXRF was used to quantitatively measure residual metals in API's and intermediates and such topics as sample preparation, sensitivity, linearity, reproducibility and accuracy are discussed. The results obtained by TXRF were compared with those obtained by ICP-MS for the same samples for Pd and Cu measurement, and statistical analysis indicated that the results obtained by the two technologies are equivalent at the 95% confidence level. A comparison is also made of the capabilities of the instruments using a tungsten (W) or a molybdenum (Mo) source for excitation. Both instruments could be used for the quantitative determination of residual metals in pharmaceuticals.

  14. A step toward standardization: development of accurate measurements of X-ray absorption and fluorescence.

    PubMed

    Chantler, Christopher T; Barnea, Zwi; Tran, Chanh Q; Rae, Nicholas A; de Jonge, Martin D

    2012-11-01

    This paper explains how to take the counting precision available for XAFS (X-ray absorption fine structure) and attenuation measurements, of perhaps one part in 10(6) in special cases, to produce a local variance below 0.01% and an accuracy of attenuation of the order 0.01%, with an XAFS accuracy at a similar level leading to the determination of dynamical bond lengths to an accuracy similar to that obtained by standard and experienced crystallographic measurements. This includes the necessary corrections for the detector response to be linear, including a correction for dark current and air-path energy dependencies; a proper interpretation of the range of sample thicknesses for absorption experiments; developments of methods to measure and correct for harmonic contamination, especially at lower energies without mirrors; the significance of correcting for the actual bandwidth of the beam on target after monochromation, especially for the portability of results and edge structure from one beamline to another; definitions of precision, accuracy and XAFS accuracy suitable for theoretical model analysis; the role of additional and alternative high-accuracy procedures; and discusses some principles regarding data formats for XAFS and for the deposition of data sets with manuscripts or to a database. Increasingly, the insight of X-ray absorption and the standard of accuracy needed requires data with high intrinsic precision and therefore with allowance for a range of small but significant systematic effects. This is always crucial for absolute measurements of absorption, and is of equal importance but traditionally difficult for (usually relative) measurements of fluorescence XAFS or even absorption XAFS. Robust error analysis is crucial so that the significance of conclusions can be tested within the uncertainties of the measurements. Errors should not just include precision uncertainty but should attempt to include estimation of the most significant systematic error

  15. X-ray fluorescence spectrometry using Synchrotron Radiation with applications in unmanned aircraft environmental sensing

    NASA Astrophysics Data System (ADS)

    Barberie, Sean Richard Gopal

    In this thesis I present an analytical optimization of the Synchrotron Radiation X-Ray Fluorescence (SR-XRF) technique for applications in unmanned aircraft aerosol studies. In environmental and atmospheric science, there is a pressing need for aerosol measurements at various altitudes in the atmosphere and spanning large regions. This need is currently either ignored, or met to a limited degree by studies that employ manned aircraft. There is, however, a great deal of opportunity to improve and expand on these studies using the emerging technology of unmanned aircraft systems. A newly developed aerosol sampler makes this opportunity a near-reality by its ability to collect aerosol samples in-situ from unmanned aircraft platforms. The challenge lies in analyzing these samples for elemental composition. In airborne aerosol studies, the ability to resolve where a sample was collected both spatially and temporally is limited by the sensitivity of the analysis technique. In aircraft-based aerosol collection, the length of the aerosol sample spot corresponds to distance. Thus the spatial resolution of an airborne study is limited by the amount of mass that must be collected for analysis. The SR-XRF optimizations outlined in this thesis decrease the amount of sample mass required for detectable elemental concentrations, allowing aerosol samples to be analyzed in smaller areas corresponding to smaller time steps. Since, in a flight path, time steps are directly correlated with distance, analysis of smaller time steps results in the ability to measure aerosols at higher spatial resolution. Four SR-XRF analysis configurations were experimentally tested: monochromatic beam, white beam, filtered white beam, and filtered white beam-filtered detector to determine which configuration gave the highest elemental sensitivity and selectivity. Of these tested methods, the straight polychromatic white beam configuration resulted in the best sensitivity for elements across a large

  16. Element distribution in the brain sections of rats measured by synchrotron radiation X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Liu, N. Q.; Zhang, F.; Wang, X. F.; Zhang, Z. Y.; Chai, Z. F.; Huang, Y. Y.; He, W.; Zhao, X. Q.; Zuo, A. J.; Yang, R.

    2004-02-01

    The concentration of trace elements in brain sections was measured by synchrotron radiation X-ray fluorescence. The relative concentration was calculated by means of the normalization of Compton scattering intensity approximately 22 keV, after the normalization for collecting time of X-ray spectrum and the counting of the ion chamber, and subtracting the contribution of the polycarbonate film for supporting sample. Furthermore, the statistical evaluation of the element distribution in various regions of the brain sections of the 20-day-old rats was tested. For investigating the distribution of elements in the brain of iodine deficient rats, Wistar rats were fed with iodine deficient diet and deionized water (ID group). The rats were fed the same iodine deficient diet, but drank KIO 3 solution as control (CT group). The results showed that the contents of calcium (Ca) in thalamus (TH) and copper (Cu) and iron (Fe) in cerebral cortex (CX) of ID rats were significantly lower than that of control rats, while the contents of phosphor (P), sulfur (S), potassium (K), rubidium (Rb), bromine (Br), chlorine (Cl), zinc (Zn), Ca and Cu of ID in hippocampus (H) and the contents of Br, Cl, Zn and Ca in cerebral cortex of ID rats were significantly higher. Especially, the difference of Br, Cl, Zn and Ca in H between ID and CT was more significant. The contents of all elements measured in H were higher than (or equal to) CX and/or TH for both groups, except low Cl of the control rats. Furthermore Zn and Cu contents along the hippocampal fissure in both groups were 1.5 ( P<0.001) and 0.87( P<0.03) times higher than in hippocampus, respectively. Considering the results of cluster analysis our study shows that the marked alterations in the spatial distribution of Zn and Ca of ID rats brain during brain development stages. In addition, the effect of the perfusion with 0.9% NaCl solution before taking brain on the distribution of elements in the brain sections was observed and

  17. X-ray Fluorescence Observations of the Moon by SMART-1/D-CIXS

    NASA Astrophysics Data System (ADS)

    Grande, Manuel; Swinyard, B.; Joy, K. H.; Kellett, Barry J.; Crawford, Ian A.; Howe, Chris J.

    2008-09-01

    Introduction The SMART-1 mission to the Moon included in its payload D-CIXS, a compact X-ray spectrometer [1], [2] SMART-1 was a technology evaluation mission, and D-CIXS was the first of a new generation of planetary X-ray spectrometers. Novel technologies enabled new capabilities for measuring the fluorescent yield of a planetary surface or atmosphere which is illuminated by solar X-rays. During the extended SMART-1 cruise phase, observations of the Earth showed strong argon emission, providing a good source for calibration and demonstrating the potential of the technique. At the Moon, observations showed a first unambiguous remote sensing of calcium in the lunar regolith (Grande et al 2007) (Fig 1). Data obtained were broadly consistent with current understanding of mare and highland composition. Ground truth was provided by the returned Apollo and Luna sample sets. We have extended our observations to comparisons of Lunar near and farside, and by careful analysis enabled new elemental lines to be observed. Observations: In March, 2005, the SMART-1 spacecraft reached its nominal lunar orbit, and we began full commissioning for lunar operations. During the pre-commissioning period in mid-January, 2005, observations of the lunar surface were made which coincided with the occurrence of several major M and X class flares. This opportunity provided an excellent chance to observe spatially localized fluorescence from the lunar surface. X-ray fluorescent elemental lines from the lunar surface are detected by all three facets of D-CIXS while the XSM instrument observes the input solar spectrum. At the end of this interval, a long duration M-class solar flare began at 06:00 UTC on the 15th of January, 2005. The flare lasted for more than 1 hour but only ~30 minutes corresponded to D-CIXS observations. At this time SMART-1 was orbiting over the Moon's near-side eastern limb from about the equator, traveling northwards. As SMART-1 flew north, its altitude was also

  18. Forensic analysis of laser printed ink by X-ray fluorescence and laser-excited plume fluorescence.

    PubMed

    Chu, Po-Chun; Cai, Bruno Yue; Tsoi, Yeuk Ki; Yuen, Ronald; Leung, Kelvin S Y; Cheung, Nai-Ho

    2013-05-01

    We demonstrated a minimally destructive two-tier approach for multielement forensic analysis of laser-printed ink. The printed document was first screened using a portable-X-ray fluorescence (XRF) probe. If the results were not conclusive, a laser microprobe was then deployed. The laser probe was based on a two-pulse scheme: the first laser pulse ablated a thin layer of the printed ink; the second laser pulse at 193 nm induced multianalytes in the desorbed ink to fluoresce. We analyzed four brands of black toners. The toners were printed on paper in the form of patches or letters or overprinted on another ink. The XRF probe could sort the four brands if the printed letters were larger than font 20. It could not tell the printing sequence in the case of overprints. The laser probe was more discriminatory; it could sort the toner brands and reveal the overprint sequence regardless of font size while the sampled area was not visibly different from neighboring areas even under the microscope. In terms of general analytical performance, the laser probe featured tens of micrometer lateral resolution and tens to hundreds of nm depth resolution and atto-mole mass detection limits. It could handle samples of arbitrary size and shape and was air compatible, and no sample pretreatment was necessary. It will prove useful whenever high-resolution and high sensitivity 3D elemental mapping is required.

  19. THE SAP3 COMPUTER PROGRAM FOR QUANTITATIVE MULTIELEMENT ANALYSIS BY ENERGY DISPERSIVE X-RAY FLUORESCENCE

    SciTech Connect

    Nielson, K. K.; Sanders, R. W.

    1982-04-01

    SAP3 is a dual-function FORTRAN computer program which performs peak analysis of energy-dispersive x-ray fluorescence spectra and then quantitatively interprets the results of the multielement analysis. It was written for mono- or bi-chromatic excitation as from an isotopic or secondary excitation source, and uses the separate incoherent and coherent backscatter intensities to define the bulk sample matrix composition. This composition is used in performing fundamental-parameter matrix corrections for self-absorption, enhancement, and particle-size effects, obviating the need for specific calibrations for a given sample matrix. The generalized calibration is based on a set of thin-film sensitivities, which are stored in a library disk file and used for all sample matrices and thicknesses. Peak overlap factors are also determined from the thin-film standards, and are stored in the library for calculating peak overlap corrections. A detailed description is given of the algorithms and program logic, and the program listing and flow charts are also provided. An auxiliary program, SPCAL, is also given for use in calibrating the backscatter intensities. SAP3 provides numerous analysis options via seventeen control switches which give flexibility in performing the calculations best suited to the sample and the user needs. User input may be limited to the name of the library, the analysis livetime, and the spectrum filename and location. Output includes all peak analysis information, matrix correction factors, and element concentrations, uncertainties and detection limits. Twenty-four elements are typically determined from a 1024-channel spectrum in one-to-two minutes using a PDP-11/34 computer operating under RSX-11M.

  20. Chemical Composition and Heterogeneity of Wild 2 Cometary Particles Determined by Synchrotron X-ray Fluorescence

    SciTech Connect

    Lanzirotti,A.; Sutton, S.; Flynn, G.; Newville, M.; Rao, W.

    2008-01-01

    Seven cometary dust particle tracks in Stardust aerogel were studied using synchrotron X-ray fluorescence methods at the National Synchrotron Light Source (NY) and Advanced Photon Source (IL). Elemental maps were produced for each of the tracks and elemental abundances for 156 individual fragments within these tracks were determined. Whole-track elemental abundances were inferred by summing the elemental masses for the fragments in each track and scaling by the ratio of total Fe in the map and total Fe in the fragments. In general, whole-track and terminal-particle abundances are dissimilar. The total Fe masses ranged from 4 to 2200 pg, corresponding to impactors in the size range of 2.7 to 22 {mu}m if Fe abundances are equal to the chondritic value. Systematic variations in element abundance with fragment distance from the aerogel entry point were generally subtle but were pronounced in one track (C2115,19). In this track, Zn/Fe was about three orders of magnitude higher at the top, Cr/Fe was two orders of magnitude higher at the bottom, and S was relatively uniform. Compositional convergence data showed that typically analysis of {approx}10 fragments was needed to reach convergent whole-track abundance. Zinc was an exception, showing nonconvergent profiles and steps due to the presence of rare, high-Zn fragments. The resulting wholetrack elemental abundances show diverse patterns that are generally chondritic (i.e., within a factor of three of CI abundances) with some exceptions, notably depletions in S and enrichments in the moderately volatile elements Cu, Zn, and Ga. Enrichments in large ion lithophile elements relative to Fe were observed in one track. Correlation matrices showed several strong elemental correlations, notably selenium associated with sulfur (sulfides), a ubiquitous correlation of the first-row transition metals Cr, Mn, and Fe attributed to the presence of pyroxene, and enrichments of gallium associated with calcium, likely affiliated with Mg

  1. Quantifying trace elements in individual aquatic protist cells with a synchrotron x-ray fluorescence microprobe.

    SciTech Connect

    Twining, B. S.; Baines, S. B.; Fisher, N. S.; Maser, J.; Vogt, S.; Jacobsen, C.; Tovar-Sanchez, A.; Sanudo-Wihelmy, S. A.; Experimental Facilities Division; Stony Brook Univ.

    2003-01-01

    The study of trace metal cycling by aquatic protists is limited by current analytical techniques. Standard 'bulk' element analysis techniques that rely on physical separations to concentrate cells for analysis cannot separate cells from co-occurring detrital material or other cells of differing taxonomy or trophic function. Here we demonstrate the ability of a synchrotron-based X-ray fluorescence (SXRF) microprobe to quantify the elements Si, Mn, Fe, Ni, and Zn in individual aquatic protist cells. This technique distinguishes between different types of cells in an assemblage and between cells and other particulate matter. Under typical operating conditions, the minimum detection limits are 7.0 x 10{sup -16} mol {mu}m{sup -2} for Si and between 5.0 x 10{sup -20} and 3.9 x 10{sup -19} mol {mu}m{sup -2} for Mn, Fe, Ni, and Zn; this sensitivity is sufficient to detect these elements in cells from even the most pristine waters as demonstrated in phytoplankton cells collected from remote areas of the Southern Ocean. Replicate analyses of single cells produced variations of <5% for Si, Mn, Fe, and Zn and <10% for Ni. Comparative analyses of cultured phytoplankton cells generally show no significant differences in cellular metal concentrations measured with SXRF and standard bulk techniques (spectrophotometry and graphite furnace atomic absorption spectrometry). SXRF also produces two-dimensional maps of element distributions in cells, thereby providing information not available with other analytical approaches. This technique enables the accurate and precise measurement of trace metals in individual aquatic protists collected from natural environments.

  2. Evaluation of a novel portable x-ray fluorescence screening tool for detection of arsenic exposure.

    PubMed

    McIver, David J; VanLeeuwen, John A; Knafla, Anthony L; Campbell, Jillian A; Alexander, Kevin M; Gherase, Mihai R; Guernsey, Judith R; Fleming, David E B

    2015-12-01

    A new portable x-ray fluorescence (XRF) screening tool was evaluated for its effectiveness in arsenic (As) quantification in human finger and toe nails ([Formula: see text]). Nail samples were measured for total As concentration by XRF and inductively coupled plasma-mass spectrometry (ICP-MS). Using concordance correlation coefficient (CCC), kappa, diagnostic sensitivity (Sn) and specificity (Sp), and linear regression analyses, the concentration of As measured by XRF was compared to ICP-MS. The CCC peaked for scaled values of fingernail samples, at 0.424 (95% CI: 0.065-0.784). The largest kappa value, 0.400 (95% CI:  -0.282-1.000), was found at a 1.3 μg g(-1) cut-off concentration, for fingernails only, and the largest kappa at a clinically relevant cut-off concentration of 1.0 μg g(-1) was 0.237 (95% CI:  -0.068-0.543), again in fingernails. Analyses generally showed excellent XRF Sn (up to 100%, 95% CI: 48-100%), but low Sp (up to 30% for the same analysis, 95% CI: 14-50%). Portable XRF shows some potential for use as a screening tool with fingernail samples. The difference between XRF and ICP-MS measurements decreased as sample mass increased to 30 mg. While this novel method of As detection in nails has shown relatively high agreement in some scenarios, this portable XRF is not currently considered suitable as a substitute for ICP-MS. PMID:26536141

  3. The role of total-reflection X-ray fluorescence in atomic spectroscopy

    NASA Astrophysics Data System (ADS)

    Tölg, G.; Klockenkämper, R.

    1993-02-01

    Total-reflection X-ray fluorescence (TXRF) is a universal and economic method for the simultaneous determination of elements with atomic numbers > 11 down to the lower pg-level. It is a microanalytical tool for the analysis of small sample amounts placed on flat carriers and for contaminations on flat sample surfaces. Analyses of stratified near-surface layers are made possible by varying the incident angle of the primary beam in the region of total-reflection. This non-destructive method is especially suitable for thin layers of a few nanometres, deposited on wafer material although not usable as a microprobe method with a high lateral resolution. Furthermore, depth profiles of biological samples can be recorded by means of microtome sectioning of only a few micrometres, as, for example in the gradient analysis of human organs. In addition to micro- and surface-layer analysis, TXRF is effectively applied to element trace analysis. Homogeneous solutions, for example aqueous solutions, high-purity adds or body fluids, are pipetted onto carriers and, after evaporation, the dry residues are analysed directly down to the pg/ml region. Particularly advantageous is the absence of matrix effects, so that an easy calibration can be carried out by adding a single internal standard element. A digestion or separation step preceding the actual determination becomes necessary if a more complex matrix is to be analysed or especially low detection limits have to be reached. A critical evaluation of the recent developments in atomic spectroscopy places TXRF in a leading position. Its outstanding features compete with those of e.g. electrothermal atomic absorption spectrometry (ETAAS), microwave induced plasma optical emission spectroscopy (MIP-OES) and inductively coupled plasma mass spectrometry (ICP-MS) in the field of micro- and trace analysis and with Rutherford backscattering (RBS) and secondary ion mass spectrometry (SIMS) in the surface-layer analysis.

  4. X-ray fluorescence analysis of rare earth elements in rocks using low dilution glass beads.

    PubMed

    Nakayama, Kenichi; Nakamura, Toshihiro

    2005-07-01

    Major and trace elements (Na, Mg, Al, Si, P, K, Ca, Ti, Mn, Fe, Rb, Sr, Y, Zr, La, Ce, Pr, Nd, Sm, Gd, Dy, Th and U) in igneous rocks were assayed with fused lithium borate glass beads using X-ray fluorescence spectrometry. Low dilution glass beads, which had a 1:1 sample-to-flux ratio, were prepared for determination of rare earth elements. Complete vitrification of 1:1 mixture required heating twice at 1200 degrees C with agitation. Extra pure reagents containing determinants were used for calibrating standards instead of the rock standard. The calibration curves of the 23 elements showed good linearity. Furthermore, the lower limits of detection corresponding to three times the standard deviation for blank measurements were 26 mass ppm for Na2O, 6.7 for MgO, 4.5 for Al2O3, 4.5 for SiO2, 18 for P2O5, 1.1 for K2O, 4.0 for CaO, 3.9 for TiO2, 1.6 for MnO, 0.8 for Fe2O3, 0.5 for Rb, 0.2 for Sr, 0.4 for Y, 0.5 for Zr, 3.3 for La, 6.5 for Ce, 2.7 for Pr, 2.1 for Nd, 1.7 for Sm, 0.7 for Gd, 2.7 for Dy, 0.5 for Th, and 0.6 for U. Using the present method, we determined the contents of these 23 elements in four rhyolitic and granitic rocks from Japan. PMID:16038502

  5. X-ray fluorescence analysis of rare earth elements in rocks using low dilution glass beads.

    PubMed

    Nakayama, Kenichi; Nakamura, Toshihiro

    2005-07-01

    Major and trace elements (Na, Mg, Al, Si, P, K, Ca, Ti, Mn, Fe, Rb, Sr, Y, Zr, La, Ce, Pr, Nd, Sm, Gd, Dy, Th and U) in igneous rocks were assayed with fused lithium borate glass beads using X-ray fluorescence spectrometry. Low dilution glass beads, which had a 1:1 sample-to-flux ratio, were prepared for determination of rare earth elements. Complete vitrification of 1:1 mixture required heating twice at 1200 degrees C with agitation. Extra pure reagents containing determinants were used for calibrating standards instead of the rock standard. The calibration curves of the 23 elements showed good linearity. Furthermore, the lower limits of detection corresponding to three times the standard deviation for blank measurements were 26 mass ppm for Na2O, 6.7 for MgO, 4.5 for Al2O3, 4.5 for SiO2, 18 for P2O5, 1.1 for K2O, 4.0 for CaO, 3.9 for TiO2, 1.6 for MnO, 0.8 for Fe2O3, 0.5 for Rb, 0.2 for Sr, 0.4 for Y, 0.5 for Zr, 3.3 for La, 6.5 for Ce, 2.7 for Pr, 2.1 for Nd, 1.7 for Sm, 0.7 for Gd, 2.7 for Dy, 0.5 for Th, and 0.6 for U. Using the present method, we determined the contents of these 23 elements in four rhyolitic and granitic rocks from Japan.

  6. Rare earth element concentrations in geological and synthetic samples using synchrotron X-ray fluorescence analysis

    USGS Publications Warehouse

    Chen, J.R.; Chao, E.C.T.; Back, J.M.; Minkin, J.A.; Rivers, M.L.; Sutton, S.R.; Cygan, G.L.; Grossman, J.N.; Reed, M.J.

    1993-01-01

    The concentrations of rare earth elements (REEs) in specific mineral grains from the Bayan Obo ore deposit and synthetic high-silica glass samples have been measured by synchrotron X-ray fluorescence (SXRF) analysis using excitation of the REE K lines between 33 and 63 keV. Because SXRF, a nondestructive analytical technique, has much lower minimum detection limits (MDLs) for REEs, it is an important device that extends the in situ analytical capability of electron probe microanalysis (EPMA). The distribution of trace amounts of REEs in common rock-forming minerals, as well as in REE minerals and minerals having minor quantities of REEs, can be analyzed with SXRF. Synchrotron radiation from a bending magnet and a wiggler source at the National Synchrotron Light Source, Brookhaven National Laboratory, was used to excite the REEs. MDLs of 6 ppm (La) to 26 ppm (Lu) for 3600 s in 60-??m-thick standard samples were obtained with a 25-??m diameter wiggler beam. The MDLs for the light REEs were a factor of 10-20 lower than the MDLs obtained with a bending magnet beam. The SXRF REE concentrations in mineral grains greater than 25 ??m compared favorably with measurements using EPMA. Because EPMA offered REE MDLs as low as several hundred ppm, the comparison was limited to the abundant light REEs (La, Ce, Pr, Nd). For trace values of medium and heavy REEs, the SXRF concentrations were in good agreement with measurements using instrumental neutron activation analysis (INAA), a bulk analysis technique. ?? 1993.

  7. Fast Monitoring Soil Environmental Qualities of Heavy Metal by Portable X-Ray Fluorescence Spectrometer.

    PubMed

    Wang, Bao; Yu, Jian-xin; Huang, Biao; Hu, Wen-you; Chang, Qing

    2015-06-01

    Portable X-ray fluorescence (PXRF) spectrometer as a new type of equipment for quick test has a prominent prospect, but there are also shortcomings of detection range and limition, therefore this paper studied the suitability of PXRF spectrometer in monitoring soil environmental qualities of heavy metals included Cr, Ni, Cu, Zn, Pb, Cd, As and Hg, the aim of this paper is to screen elements which can be detected by this kind of instrument and evaluate the accuracy of test results. The research method is to test heavy metals contaminated soil samples by PXRF spectrometer, evaluate the accuracy of test results of PXRF compared with inductively coupled plasma mass(ICP-MS), then establish linear regression relationship between analysis results of PXRF and ICP-MS method. The results show that, (1) When measuring the soil environmental quality, PXRF spectrometer is appropriate to measure the content of Pb, Zn, Cr and Cu, except Ni, Cd, As and Hg. (2) Compared with the test value of ICP-MS, the test value of Pb and Zn is lower, the test value of Cu is higher, the test value of Cr is too high, all the results of PXRF spectrometer should be linear corrected according to standard analysis method. In conclusion, PXRF spectrometer is suitable for monitoring environmental quality of soil which is polluted by heavy metal such as Pb, Zn, Cr and Cu, it is an analysis means with characteristics of simple and rapid, accurate and reliable. The innovation of this article is that reasonable avoiding the shortcomings of PXRF spectrometer as using the instrument to monitor soil environmental quality, at last improved the application value of test results.

  8. Quantification of total element concentrations in soils using total X-ray fluorescence spectroscopy (TXRF).

    PubMed

    Towett, Erick K; Shepherd, Keith D; Cadisch, Georg

    2013-10-01

    Total X-ray fluorescence spectroscopy (TXRF) determines concentrations of major and trace elements in multiple media. We developed and tested a method for the use of TXRF for direct quantification of total element concentrations in soils using an S2 PICOFOX™ spectrometer (Bruker AXS Microanalysis GmbH, Germany). We selected 15 contrasting soil samples from across sub-Saharan Africa for element analysis to calibrate the instrument against concentrations determined using the inductively coupled plasma-mass spectroscopy (ICP-MS) standard method. A consistent underestimation of element concentrations using TXRF compared to ICP-MS reference analysis occurred, indicating that spectrometer recalibration was required. Single-element recalibration improved the TXRF spectrometer's sensitivity curve. Subsequent analysis revealed that TXRF determined total element concentrations of Al, K, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, and Ga accurately (model efficacy/slope close to 1:1 line, and R(2)>0.80) over a wide range of soil samples. Other elements that could be estimated with an acceptable precision (R(2)>0.60) compared with ICP-MS although generally somewhat under- or overestimated were P, Ca, As, Rb, Sr, Y, Pr, Ta and Pb. Even after recalibration, compared to ICP-MS the TXRF spectrometer produced underestimations for elements Na, Mg, Ba, Ce, Hf, La, Nd, W and Sm and overestimations for elements Bi, Tl and Zr. We validated the degree of accuracy of the TXRF analytical method after recalibration using an independent set of 20 soil samples. We also tested the accuracy of the analysis using 2 multi-element standards as well as the method repeatability on replicate samples. The resulting total element concentration repeatability for all elements analyzed were within 10% coefficient of variability after the instrument recalibration except for Cd and Tl. Our findings demonstrate that TXRF could be used as a rapid screening tool for total element concentrations in soils assuming that

  9. Quantifying trace elements in individual aquatic protist cells with a synchrotron X-ray fluorescence microprobe.

    PubMed

    Twining, Benjamin S; Baines, Stephen B; Fisher, Nicholas S; Maser, Jörg; Vogt, Stefan; Jacobsen, Chris; Tovar-Sanchez, Antonio; Sañudo-Wilhelmy, Sergio A

    2003-08-01

    The study of trace metal cycling by aquatic protists is limited by current analytical techniques. Standard "bulk" element analysis techniques that rely on physical separations to concentrate cells for analysis cannot separate cells from co-occurring detrital material or other cells of differing taxonomy or trophic function. Here we demonstrate the ability of a synchrotron-based X-ray fluorescence (SXRF) microprobe to quantify the elements Si, Mn, Fe, Ni, and Zn in individual aquatic protist cells. This technique distinguishes between different types of cells in an assemblage and between cells and other particulate matter. Under typical operating conditions, the minimum detection limits are 7.0 x 10(-16) mol microm(-2) for Si and between 5.0 x 10(-20) and 3.9 x 10(-19) mol microm(-2) for Mn, Fe, Ni, and Zn; this sensitivity is sufficient to detect these elements in cells from even the most pristine waters as demonstrated in phytoplankton cells collected from remote areas of the Southern Ocean. Replicate analyses of single cells produced variations of <5% for Si, Mn, Fe, and Zn and <10% for Ni. Comparative analyses of cultured phytoplankton cells generally show no significant differences in cellular metal concentrations measured with SXRF and standard bulk techniques (spectrophotometry and graphite furnace atomic absorption spectrometry). SXRF also produces two-dimensional maps of element distributions in cells, thereby providing information not available with other analytical approaches. This technique enables the accurate and precise measurement of trace metals in individual aquatic protists collected from natural environments.

  10. Evaluation of a novel portable x-ray fluorescence screening tool for detection of arsenic exposure.

    PubMed

    McIver, David J; VanLeeuwen, John A; Knafla, Anthony L; Campbell, Jillian A; Alexander, Kevin M; Gherase, Mihai R; Guernsey, Judith R; Fleming, David E B

    2015-12-01

    A new portable x-ray fluorescence (XRF) screening tool was evaluated for its effectiveness in arsenic (As) quantification in human finger and toe nails ([Formula: see text]). Nail samples were measured for total As concentration by XRF and inductively coupled plasma-mass spectrometry (ICP-MS). Using concordance correlation coefficient (CCC), kappa, diagnostic sensitivity (Sn) and specificity (Sp), and linear regression analyses, the concentration of As measured by XRF was compared to ICP-MS. The CCC peaked for scaled values of fingernail samples, at 0.424 (95% CI: 0.065-0.784). The largest kappa value, 0.400 (95% CI:  -0.282-1.000), was found at a 1.3 μg g(-1) cut-off concentration, for fingernails only, and the largest kappa at a clinically relevant cut-off concentration of 1.0 μg g(-1) was 0.237 (95% CI:  -0.068-0.543), again in fingernails. Analyses generally showed excellent XRF Sn (up to 100%, 95% CI: 48-100%), but low Sp (up to 30% for the same analysis, 95% CI: 14-50%). Portable XRF shows some potential for use as a screening tool with fingernail samples. The difference between XRF and ICP-MS measurements decreased as sample mass increased to 30 mg. While this novel method of As detection in nails has shown relatively high agreement in some scenarios, this portable XRF is not currently considered suitable as a substitute for ICP-MS.

  11. Visualizing Metal Content and Intracellular Distribution in Primary Hippocampal Neurons with Synchrotron X-Ray Fluorescence

    PubMed Central

    2016-01-01

    Increasing evidence suggests that metal dyshomeostasis plays an important role in human neurodegenerative diseases. Although distinctive metal distributions are described for mature hippocampus and cortex, much less is known about metal levels and intracellular distribution in individual hippocampal neuronal somata. To solve this problem, we conducted quantitative metal analyses utilizing synchrotron radiation X-Ray fluorescence on frozen hydrated primary cultured neurons derived from rat embryonic cortex (CTX) and two regions of the hippocampus: dentate gyrus (DG) and CA1. Comparing average metal contents showed that the most abundant metals were calcium, iron, and zinc, whereas metals such as copper and manganese were less than 10% of zinc. Average metal contents were generally similar when compared across neurons cultured from CTX, DG, and CA1, except for manganese that was larger in CA1. However, each metal showed a characteristic spatial distribution in individual neuronal somata. Zinc was uniformly distributed throughout the cytosol, with no evidence for the existence of previously identified zinc-enriched organelles, zincosomes. Calcium showed a peri-nuclear distribution consistent with accumulation in endoplasmic reticulum and/or mitochondria. Iron showed 2–3 distinct highly concentrated puncta only in peri-nuclear locations. Notwithstanding the small sample size, these analyses demonstrate that primary cultured neurons show characteristic metal signatures. The iron puncta probably represent iron-accumulating organelles, siderosomes. Thus, the metal distributions observed in mature brain structures are likely the result of both intrinsic neuronal factors that control cellular metal content and extrinsic factors related to the synaptic organization, function, and contacts formed and maintained in each region. PMID:27434052

  12. X-ray fluorescence imaging of the hippocampal formation after manganese exposure.

    PubMed

    Robison, Gregory; Zakharova, Taisiya; Fu, Sherleen; Jiang, Wendy; Fulper, Rachael; Barrea, Raul; Zheng, Wei; Pushkar, Yulia

    2013-11-01

    Manganese (Mn) intoxication results in neurological conditions similar, but not identical, to idiopathic Parkinson's disease. While the mechanism(s) by which Mn exposure leads to neurotoxic effects remains unclear, studies by magnetic resonance imaging demonstrate a high Mn accumulation in the hippocampal formation (HPCf) of the brain. Metal quantification using this method is not possible. Using X-ray fluorescence imaging, we measured the distribution of Mn in the HPCf for a rodent model of chronic Mn exposure and quantitatively compared it with distributions of other biologically relevant metals. We found considerable increases in average Mn concentrations in all analyzed areas and we identified the dentate gyrus (DG) and the cornus ammonis 3 (CA3) layer as areas accumulating the highest Mn content (∼1.2 μg Mn per g tissue). The DG is significantly enriched with iron (Fe), while the CA3 layer has high zinc (Zn) content. Additionally, significant spatial correlations were found for Mn-Zn concentrations across the HPCf substructures and for Mn-Fe concentrations in the DG. Combined results support that at least two mechanisms may be responsible for Mn transport and/or storage in the brain, associated with either Fe or Zn. Subcellular resolution images of metal distribution in cells of the CA3 show diffuse Mn distributions consistent with Mn localization in both the cytoplasm and nucleus. Mn was not increased in localized intracellular Fe or copper accumulations. A consistent Mn-Zn correlation both at the tissue (40 μm × 40 μm) and cellular (0.3 μm × 0.3 μm) levels suggests that a Zn transport/storage mechanism in the HPCf is likely associated with Mn accumulation. PMID:23999853

  13. X-ray fluorescence imaging: a new tool for studying manganese neurotoxicity.

    PubMed

    Robison, Gregory; Zakharova, Taisiya; Fu, Sherleen; Jiang, Wendy; Fulper, Rachael; Barrea, Raul; Marcus, Matthew A; Zheng, Wei; Pushkar, Yulia

    2012-01-01

    The neurotoxic effect of manganese (Mn) establishes itself in a condition known as manganism or Mn induced parkinsonism. While this condition was first diagnosed about 170 years ago, the mechanism of the neurotoxic action of Mn remains unknown. Moreover, the possibility that Mn exposure combined with other genetic and environmental factors can contribute to the development of Parkinson's disease has been discussed in the literature and several epidemiological studies have demonstrated a correlation between Mn exposure and an elevated risk of Parkinson's disease. Here, we introduce X-ray fluorescence imaging as a new quantitative tool for analysis of the Mn distribution in the brain with high spatial resolution. The animal model employed mimics deficits observed in affected human subjects. The obtained maps of Mn distribution in the brain demonstrate the highest Mn content in the globus pallidus, the thalamus, and the substantia nigra pars compacta. To test the hypothesis that Mn transport into/distribution within brain cells mimics that of other biologically relevant metal ions, such as iron, copper, or zinc, their distributions were compared. It was demonstrated that the Mn distribution does not follow the distributions of any of these metals in the brain. The majority of Mn in the brain was shown to occur in the mobile state, confirming the relevance of the chelation therapy currently used to treat Mn intoxication. In cells with accumulated Mn, it can cause neurotoxic action by affecting the mitochondrial respiratory chain. This can result in increased susceptibility of the neurons of the globus pallidus, thalamus, and substantia nigra pars compacta to various environmental or genetic insults. The obtained data is the first demonstration of Mn accumulation in the substantia nigra pars compacta, and thus, can represent a link between Mn exposure and its potential effects for development of Parkinson's disease. PMID:23185282

  14. Measuring plant available phosphorus using diffusive gradients in thin films and x-ray fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Rothwell, Shane; Surridge, Ben; Dodd, Ian; Quinton, John; Zhang, Hao

    2015-04-01

    Global concerns of phosphorus (P) deficiency limiting crop yields, and finite supplies of mineral P reserves, suggest a need to maximise P use efficiency in agriculture. To accurately predict the availability of soil P to crops, and subsequent P fertiliser recommendations, soil P tests must determine only the P that will be accessed and utilised by a crop. However, there is growing doubt regarding the ability of current extraction techniques (water, bicarbonate, resin) to accurately determine plant-available P across a range of soils. Indeed, the most widely-used test (Olsen P) across all soil types was only designed for alkaline soils and therefore it is inappropriate as a national standard soil test. Thus, there is an urgent need to develop a standard approach to measuring P availability applicable across a range of soil types. Diffusive Gradients in Thin Films (DGT) may be a more accurate technique for measuring the P available to plants than P measured using current extraction techniques because the measurement responds to both soil solution P and the P rapidly resupplied from the solid phase. However, elution by acid extraction of P retained within the resin gel of a DGT device, followed by analysis via inductively coupled plasma-based techniques, typically results in a delay of several days between DGT deployment and reporting of P concentrations. This is currently a significant constraint on the adoption of DGT to determine plant-available P in agricultural soils. Our research seeks to develop a novel combination of two existing techniques, DGT with portable x-ray fluorescence spectrometry (pXRF) to achieve rapid, non-destructive analysis of P within a DGT device, thus significantly reducing the length of time between DGT deployment and the final determination of plant-available P in agricultural soils. We aim to develop DGT-pXRF as a robust routine analytical procedure suitable for analysis of plant available P in a wide range of agricultural soil types.

  15. X-Ray Fluorescence Imaging: A New Tool for Studying Manganese Neurotoxicity

    PubMed Central

    Robison, Gregory; Zakharova, Taisiya; Fu, Sherleen; Jiang, Wendy; Fulper, Rachael; Barrea, Raul; Marcus, Matthew A.; Zheng, Wei; Pushkar, Yulia

    2012-01-01

    The neurotoxic effect of manganese (Mn) establishes itself in a condition known as manganism or Mn induced parkinsonism. While this condition was first diagnosed about 170 years ago, the mechanism of the neurotoxic action of Mn remains unknown. Moreover, the possibility that Mn exposure combined with other genetic and environmental factors can contribute to the development of Parkinson's disease has been discussed in the literature and several epidemiological studies have demonstrated a correlation between Mn exposure and an elevated risk of Parkinson's disease. Here, we introduce X-ray fluorescence imaging as a new quantitative tool for analysis of the Mn distribution in the brain with high spatial resolution. The animal model employed mimics deficits observed in affected human subjects. The obtained maps of Mn distribution in the brain demonstrate the highest Mn content in the globus pallidus, the thalamus, and the substantia nigra pars compacta. To test the hypothesis that Mn transport into/distribution within brain cells mimics that of other biologically relevant metal ions, such as iron, copper, or zinc, their distributions were compared. It was demonstrated that the Mn distribution does not follow the distributions of any of these metals in the brain. The majority of Mn in the brain was shown to occur in the mobile state, confirming the relevance of the chelation therapy currently used to treat Mn intoxication. In cells with accumulated Mn, it can cause neurotoxic action by affecting the mitochondrial respiratory chain. This can result in increased susceptibility of the neurons of the globus pallidus, thalamus, and substantia nigra pars compacta to various environmental or genetic insults. The obtained data is the first demonstration of Mn accumulation in the substantia nigra pars compacta, and thus, can represent a link between Mn exposure and its potential effects for development of Parkinson's disease. PMID:23185282

  16. Effects of amiodarone therapy on thyroid iodine content as measured by x-ray fluorescence

    SciTech Connect

    Fragu, P.; Schlumberger, M.; Davy, J.M.; Slama, M.; Berdeaux, A.

    1988-04-01

    Thyroid iodine content (TIC) was measured by x-ray fluorescence in 68 patients who had received amiodarone treatment for varying intervals (1 g/week for 1-120 months). Thirty-six patients were euthyroid; the mean TIC of the patients (n = 15), who had been treated for less than 12 months was 30 +/- 19 (+/- SD) mg, twice the normal mean value (14.6 +/- 5.0 mg), and it was 39 +/- 17 mg in those (n = 16) who had been treated for 12-60 months and 29 +/- 6 mg in those (n = 5) who had been treated longer (greater than 60 months). Nineteen patients were hyperthyroid and had elevated TIC values. Of them, 6 patients had a goiter; their TIC (50 +/- 19 mg) was not significantly different from that of the hyperthyroid patients with no goiter (55 +/- 29 mg), but they became hyperthyroid more rapidly. Thirteen patients were hypothyroid; none had TIC values above the normal range, and it was below 2.5 mg in 5 patients. A sequential study was undertaken in 11 euthyroid patients who had no detectable antithyroid antibodies. TIC did not increase during treatment in 2 patients; both developed hypothyroidism, which was transient in 1 despite continuation of amiodarone treatment. The TIC initially increased during amiodarone treatment in the other 9 patients, leveling off at the end of the first year. The TIC rose well above the upper limit of the normal range in 4 patients, of whom 2 became hyperthyroid during the second year of treatment. TIC remained within the normal range in the other 5 patients, of whom 3 became hypothyroid after 12-24 months of treatment (1 subclinical, 2 overt). Although the TIC was significantly higher in the patients with hyperthyroidism than in the patients who remained euthyroid, the TIC test cannot be used to predict the occurrence of hyperthyroidism.

  17. Perspectives on heterococcolith geochemical proxies based on high-resolution X-ray fluorescence mapping.

    PubMed

    Suchéras-Marx, B; Giraud, F; Simionovici, A; Daniel, I; Tucoulou, R

    2016-07-01

    Heterococcoliths are micron-scale calcite platelets produced by coccolithophores. They have been the most abundant and continuous fossil record over the last 215 million years (Myr), offering great potential for geochemical studies, although the heterococcolith fossil record remains underutilised in this domain. We have mapped heterococcoliths' composition using X-ray fluorescence (XRF) with a 100-nm resolution beam to decipher element distributions in heterococcoliths and to investigate the potential development of geochemical proxies for palaeoceanography. The study presents two Middle Jurassic Watznaueria britannica heterococcoliths from Cabo Mondego, Portugal. XRF analysis was performed with a 17 keV incident energy beam at the European Synchrotron Radiation Facility ID22NI beamline to study elements from Sr down to S. Ca, Sr and Mn are distributed following the heterococcolith crystalline arrangement. Cl, Br and S display an homogeneous distribution, whereas K, Fe, Cu, Zn and Rb are concentrated at the edges and in the central area of the heterococcoliths. Distributions of K, Fe, Ti, Fe, Cu, Zn, Rb and to a lesser extent V and Cr are highly influenced by clay contamination and peripheral diagenetic overgrowth. Mn is related to diagenetic Mn-rich CaCO3 overgrowth on top of or between heterococcoliths shields. Cl and Br are likely to be present in heterococcoliths inside interstitial nano-domains. We assume that the cytoplasm [Cl(-) ] and [Br(-) ] are mediated and constant during heterococcolithogenesis. Assuming a linear correlation between cytoplasm [Cl(-) ] and sea water [Cl(-) ], heterococcolith Cl may have potential as a salinity proxy. As S is incorporated into heterococcoliths by sulphated polysaccharides, our study suggests a role for such polysaccharides in heterococcolithogenesis for at least 170 Myr. The low Sr/Ca in the W. britannica specimens studied here may either highlight an unusual cellular physiology of Mesozoic coccolithophores or result

  18. Visualizing Metal Content and Intracellular Distribution in Primary Hippocampal Neurons with Synchrotron X-Ray Fluorescence.

    PubMed

    Colvin, Robert A; Jin, Qiaoling; Lai, Barry; Kiedrowski, Lech

    2016-01-01

    Increasing evidence suggests that metal dyshomeostasis plays an important role in human neurodegenerative diseases. Although distinctive metal distributions are described for mature hippocampus and cortex, much less is known about metal levels and intracellular distribution in individual hippocampal neuronal somata. To solve this problem, we conducted quantitative metal analyses utilizing synchrotron radiation X-Ray fluorescence on frozen hydrated primary cultured neurons derived from rat embryonic cortex (CTX) and two regions of the hippocampus: dentate gyrus (DG) and CA1. Comparing average metal contents showed that the most abundant metals were calcium, iron, and zinc, whereas metals such as copper and manganese were less than 10% of zinc. Average metal contents were generally similar when compared across neurons cultured from CTX, DG, and CA1, except for manganese that was larger in CA1. However, each metal showed a characteristic spatial distribution in individual neuronal somata. Zinc was uniformly distributed throughout the cytosol, with no evidence for the existence of previously identified zinc-enriched organelles, zincosomes. Calcium showed a peri-nuclear distribution consistent with accumulation in endoplasmic reticulum and/or mitochondria. Iron showed 2-3 distinct highly concentrated puncta only in peri-nuclear locations. Notwithstanding the small sample size, these analyses demonstrate that primary cultured neurons show characteristic metal signatures. The iron puncta probably represent iron-accumulating organelles, siderosomes. Thus, the metal distributions observed in mature brain structures are likely the result of both intrinsic neuronal factors that control cellular metal content and extrinsic factors related to the synaptic organization, function, and contacts formed and maintained in each region. PMID:27434052

  19. Asymmetri Distribution of Metals in the Xenopus Laevis Oocyte: a Synchrotron X-Ray Fluorescence Microprobe Study

    SciTech Connect

    Popescu, B.F.G.; Belak, Z.R.; Ignatyev, K.; Ovsenek, N.; Nichol, H.; /Saskatchewan U. /SLAC, SSRL

    2009-04-29

    The asymmetric distribution of many components of the Xenopus oocyte, including RNA, proteins, and pigment, provides a framework for cellular specialization during development. During maturation, Xenopus oocytes also acquire metals needed for development, but apart from zinc, little is known about their distribution. Synchrotron X-ray fluorescence microprobe was used to map iron, copper, and zinc and the metalloid selenium in a whole oocyte. Iron, zinc, and copper were asymmetrically distributed in the cytoplasm, while selenium and copper were more abundant in the nucleus. A zone of high copper and zinc was seen in the animal pole cytoplasm. Iron was also concentrated in the animal pole but did not colocalize with zinc, copper, or pigment accumulations. This asymmetry of metal deposition may be important for normal development. Synchrotron X-ray fluorescence microprobe will be a useful tool to examine how metals accumulate and redistribute during fertilization and embryonic development.

  20. Asymmetric Distribution of Metals in the Xenopus Laevis Oocyte: a Synchrotron X-Ray Fluorescence Microprobe Study

    SciTech Connect

    Popescu, B.F.Gh.; Belak, Z.R.; Ignatyev, K.; Ovsenek, N.; Nichol, H.

    2009-06-04

    The asymmetric distribution of many components of the Xenopus oocyte, including RNA, proteins, and pigment, provides a framework for cellular specialization during development. During maturation, Xenopus oocytes also acquire metals needed for development, but apart from zinc, little is known about their distribution. Synchrotron X-ray fluorescence microprobe was used to map iron, copper, and zinc and the metalloid selenium in a whole oocyte. Iron, zinc, and copper were asymmetrically distributed in the cytoplasm, while selenium and copper were more abundant in the nucleus. A zone of high copper and zinc was seen in the animal pole cytoplasm. Iron was also concentrated in the animal pole but did not colocalize with zinc, copper, or pigment accumulations. This asymmetry of metal deposition may be important for normal development. Synchrotron X-ray fluorescence microprobe will be a useful tool to examine how metals accumulate and redistribute during fertilization and embryonic development.

  1. Pb distribution in bones from the Franklin expedition: synchrotron X-ray fluorescence and laser ablation/mass spectroscopy

    NASA Astrophysics Data System (ADS)

    Martin, Ronald Richard; Naftel, Steven; Macfie, Sheila; Jones, Keith; Nelson, Andrew

    2013-04-01

    Synchrotron micro-X-ray Fluorescence has been used to map the metal distribution in selected bone fragments representative of remains associated with the Franklin expedition. In addition, laser ablation mass spectroscopy using a 25 μm diameter circular spot was employed to compare the Pb isotope distributions in small regions within the bone fragments. The X-ray Fluorescence mapping shows Pb to be widely distributed in the bone while the Pb isotope ratios obtained by laser ablation within small areas representative of bone with different Pb exchange rates do not show statistically significant differences. These results are inconsistent with the hypothesis that faulty solder seals in tinned meat were the principle source of Pb in the remains of the expedition personnel.

  2. Transmission-corrected x-ray fluorescence analysis of uranium and plutonium solutions using a dual transmission source

    SciTech Connect

    Ruhter, W.D.; Camp, D.C.

    1987-11-24

    The energy-dispersive x-ray fluorescence analysis (XRFA) technique has been implemented at several spent nuclear fuel reprocessing facilities for nondestructive measurements of uranium and/or plutonium concentrations in process streams and product storage tanks. An important factor in these quantitative measurements is the absorption of the fluoresced x-rays by the solution matrix, which must be taken into account to accurately quantify the U or Pu concentrations. We describe a new, accurate method using a dual transmission source of Gd-153 and Co-57 to correct for matrix effects. Results of measurements on uranium and plutonium solution standards show the methodology to be better than 0.5%, which includes statistical precision, over the concentration range from 1 to 250 g/l. 5 refs., 4 figs., 3 tabs.

  3. A fluorescence XAFS measurement instrument in the soft x-ray region toward observation under operando conditions

    SciTech Connect

    Honda, M. Baba, Y.; Shimoyama, I.; Sekiguchi, T.

    2015-03-15

    X-ray absorption fine structure (XAFS) measurements are widely used for the analysis of electronic structure. Generally, XAFS in the soft X-ray region is measured under vacuum, but chemical structures under vacuum are typically different from those under operando conditions, where chemical species exhibit their function. Here, we developed an XAFS measurement instrument, as a step toward operando fluorescent, which yields XAFS measurement using synchrotron radiation in the soft X-ray region. We applied this method to analyze the local electronic structure of the sulfur atoms in L-cysteine in different pH solutions. In water at pH 7, the hydrogen atom does not dissociate from the thiol (-SH) group in L-cysteine, which forms a structure surrounded by and interacting with water molecules. The XAFS spectrum of L-cysteine in solution was altered by changing the pH. At pH 9, the hydrogen atom dissociated and a thiolate anion was formed. Although the -SH group was oxidized to SO{sub 4}{sup 2−} when L-cysteine was adsorbed on a metal surface and dried, no oxidation was observed in solution. This may be because the water molecules were densely packed and protected the -SH group from oxidation. Our results show that this instrument aimed toward operando fluorescence XAFS measurements in the soft X-ray region is useful for structural analysis of sulfur atoms in organic molecules in air and in solution. The instrument will be applied to the structural analysis of materials containing elements that have absorption edges in soft X-ray region, such as phosphorus and alkali metals (potassium and cesium). It will be also particularly useful for the analysis of samples that are difficult to handle under vacuum and materials that have specific functions in solution.

  4. Elemental analysis with a full-field X-ray fluorescence microscope and a CCD photon-counting system.

    PubMed

    Ohigashi, Takuji; Watanabe, Norio; Yokosuka, Hiroki; Aota, Tatsuya; Takano, Hidekazu; Takeuchi, Akihisa; Aoki, Sadao

    2002-05-01

    The first result is presented of an X-ray fluorescence microscope with a Wolter mirror in combination with a CCD camera used as an energy-resolved two-dimensional detector in photon-counting mode. Two-dimensional elemental maps of metallic wires, such as Fe, Co, Ni and Cu, and inclusions of a synthesized diamond could be obtained with an energy resolution of 350 eV. PMID:11972365

  5. Determination of calcium and iodine in gall bladder stone using energy dispersive X-ray fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Ekinci, Neslihan; Şahin, Yusuf

    2002-01-01

    Energy dispersive X-ray fluorescence techniques were used to analyze gall bladder stones. Enrichment of Ca and I was observed in the gall bladder stone taken from a patient. The concentration of Ca has been determined with an annular 55Fe radioactive source and the concentration of I with an annular 241Am radioactive source using the standard addition method in 2π geometry. A Si(Li)-detector was used to measure Ca and I concentrations in the gall bladder stones.

  6. Chemical Environment Effects on K[beta]/K[alpha] Intensity Ratio: An X-Ray Fluorescence Experiment on Periodic Trends

    ERIC Educational Resources Information Center

    Durham, Chaney R.; Chase, Jeffery M.; Nivens, Delana A.; Baird, William H.; Padgett, Clifford W.

    2011-01-01

    X-ray fluorescence (XRF) data from an energy-dispersive XRF instrument were used to investigate the chlorine K[alpha] and K[beta] peaks in several group 1 salts. The ratio of the peak intensity is sensitive to the local chemical environment of the chlorine atoms studied in this experiment and it shows a periodic trend for these salts. (Contains 1…

  7. Synchrotron-induced X-ray fluorescence from rat bone and lumber vertebra of different age groups

    NASA Astrophysics Data System (ADS)

    Rao, Donepudi V.; Swapna, Medasani; Cesareo, Roberto; Brunetti, Antonio; Akatsuka, Tako; Yuasa, Tetsuya; Takeda, Tohoru; Tromba, Giuliana; Gigante, Giovanni E.

    2009-02-01

    The fluorescence spectra from rat bones of different age groups (8, 56 and 78 weeks) and lumber vertebra were measured with 8, 10 and 12 keV synchrotron X-rays. We have utilized the new hard X-ray micro-spectroscopy beamline facility, X27A, available at NSLS with a primary beam spot size of the order of ˜10 μm. With this spatial resolution and high flux throughput, X-ray fluorescent intensities for Ca and other trace elements were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. Regarding the lumber vertebra, we acquired the fluorescence spectra from the left, right and middle portions and calcium accumulation was evaluated and compared with the other samples. We have identified the major trace elements of Ca, Ni, Fe and Zn and minor trace elements of Ti, Cr and Mn in the sample. The percentage of scattered radiation and trace element contributions from these samples were highlighted at different energies.

  8. Monte Carlo simulation of energy-dispersive x-ray fluorescence and applications

    NASA Astrophysics Data System (ADS)

    Li, Fusheng

    Four key components with regards to Monte Carlo Library Least Squares (MCLLS) have been developed by the author. These include: a comprehensive and accurate Monte Carlo simulation code - CEARXRF5 with Differential Operators (DO) and coincidence sampling, Detector Response Function (DRF), an integrated Monte Carlo - Library Least-Squares (MCLLS) Graphical User Interface (GUI) visualization System (MCLLSPro) and a new reproducible and flexible benchmark experiment setup. All these developments or upgrades enable the MCLLS approach to be a useful and powerful tool for a tremendous variety of elemental analysis applications. CEARXRF, a comprehensive and accurate Monte Carlo code for simulating the total and individual library spectral responses of all elements, has been recently upgraded to version 5 by the author. The new version has several key improvements: input file format fully compatible with MCNP5, a new efficient general geometry tracking code, versatile source definitions, various variance reduction techniques (e.g. weight window mesh and splitting, stratifying sampling, etc.), a new cross section data storage and accessing method which improves the simulation speed by a factor of four and new cross section data, upgraded differential operators (DO) calculation capability, and also an updated coincidence sampling scheme which including K-L and L-L coincidence X-Rays, while keeping all the capabilities of the previous version. The new Differential Operators method is powerful for measurement sensitivity study and system optimization. For our Monte Carlo EDXRF elemental analysis system, it becomes an important technique for quantifying the matrix effect in near real time when combined with the MCLLS approach. An integrated visualization GUI system has been developed by the author to perform elemental analysis using iterated Library Least-Squares method for various samples when an initial guess is provided. This software was built on the Borland C++ Builder

  9. Fluorescence imaging of reactive oxygen species by confocal laser scanning microscopy for track analysis of synchrotron X-ray photoelectric nanoradiator dose: X-ray pump-optical probe.

    PubMed

    Jeon, Jae Kun; Han, Sung Mi; Kim, Jong Ki

    2016-09-01

    Bursts of emissions of low-energy electrons, including interatomic Coulomb decay electrons and Auger electrons (0-1000 eV), as well as X-ray fluorescence produced by irradiation of large-Z element nanoparticles by either X-ray photons or high-energy ion beams, is referred to as the nanoradiator effect. In therapeutic applications, this effect can damage pathological tissues that selectively take up the nanoparticles. Herein, a new nanoradiator dosimetry method is presented that uses probes for reactive oxygen species (ROS) incorporated into three-dimensional gels, on which macrophages containing iron oxide nanoparticles (IONs) are attached. This method, together with site-specific irradiation of the intracellular nanoparticles from a microbeam of polychromatic synchrotron X-rays (5-14 keV), measures the range and distribution of OH radicals produced by X-ray emission or superoxide anions ({\\rm{O}}_2^-) produced by low-energy electrons. The measurements are based on confocal laser scanning of the fluorescence of the hydroxyl radical probe 2-[6-(4'-amino)phenoxy-3H-xanthen-3-on-9-yl] benzoic acid (APF) or the superoxide probe hydroethidine-dihydroethidium (DHE) that was oxidized by each ROS, enabling tracking of the radiation dose emitted by the nanoradiator. In the range 70 µm below the irradiated cell, ^\\bullet{\\rm{OH}} radicals derived mostly from either incident X-ray or X-ray fluorescence of ION nanoradiators are distributed along the line of depth direction in ROS gel. In contrast, {\\rm{O}}_2^- derived from secondary electron or low-energy electron emission by ION nanoradiators are scattered over the ROS gel. ROS fluorescence due to the ION nanoradiators was observed continuously to a depth of 1.5 mm for both oxidized APF and oxidized DHE with relatively large intensity compared with the fluorescence caused by the ROS produced solely by incident primary X-rays, which was limited to a depth of 600 µm, suggesting dose enhancement as well as more

  10. Fluorescence imaging of reactive oxygen species by confocal laser scanning microscopy for track analysis of synchrotron X-ray photoelectric nanoradiator dose: X-ray pump-optical probe.

    PubMed

    Jeon, Jae Kun; Han, Sung Mi; Kim, Jong Ki

    2016-09-01

    Bursts of emissions of low-energy electrons, including interatomic Coulomb decay electrons and Auger electrons (0-1000 eV), as well as X-ray fluorescence produced by irradiation of large-Z element nanoparticles by either X-ray photons or high-energy ion beams, is referred to as the nanoradiator effect. In therapeutic applications, this effect can damage pathological tissues that selectively take up the nanoparticles. Herein, a new nanoradiator dosimetry method is presented that uses probes for reactive oxygen species (ROS) incorporated into three-dimensional gels, on which macrophages containing iron oxide nanoparticles (IONs) are attached. This method, together with site-specific irradiation of the intracellular nanoparticles from a microbeam of polychromatic synchrotron X-rays (5-14 keV), measures the range and distribution of OH radicals produced by X-ray emission or superoxide anions ({\\rm{O}}_2^-) produced by low-energy electrons. The measurements are based on confocal laser scanning of the fluorescence of the hydroxyl radical probe 2-[6-(4'-amino)phenoxy-3H-xanthen-3-on-9-yl] benzoic acid (APF) or the superoxide probe hydroethidine-dihydroethidium (DHE) that was oxidized by each ROS, enabling tracking of the radiation dose emitted by the nanoradiator. In the range 70 µm below the irradiated cell, ^\\bullet{\\rm{OH}} radicals derived mostly from either incident X-ray or X-ray fluorescence of ION nanoradiators are distributed along the line of depth direction in ROS gel. In contrast, {\\rm{O}}_2^- derived from secondary electron or low-energy electron emission by ION nanoradiators are scattered over the ROS gel. ROS fluorescence due to the ION nanoradiators was observed continuously to a depth of 1.5 mm for both oxidized APF and oxidized DHE with relatively large intensity compared with the fluorescence caused by the ROS produced solely by incident primary X-rays, which was limited to a depth of 600 µm, suggesting dose enhancement as well as more

  11. Evaluation on the stability of Hg in ABS disk CRM during measurements by wavelength dispersive X-ray fluorescence spectrometry.

    PubMed

    Ohata, Masaki; Kidokoro, Toshihiro; Hioki, Akiharu

    2012-01-01

    The stability of Hg in an acrylonitrile-butadiene-styrene disk certified reference material (ABS disk CRM, NMIJ CRM 8116-a) during measurements by wavelength dispersion X-ray fluorescence (WD-XRF) analysis was evaluated in this study. The XRF intensities of Hg (L(α)) and Pb (L(α)) as well as the XRF intensity ratios of Hg (L(α))/Pb (L(α)) observed under different X-ray tube current conditions as well as their irradiation time were examined to evaluate the stability of Hg in the ABS disk CRM. The observed XRF intensities and the XRF intensity ratios for up to 32 h of measurements under 80 mA of X-ray tube current condition were constant, even though the surface of the ABS disk CRM was charred by the X-ray irradiation with high current for a long time. Moreover, the measurements on Hg and Pb in the charred disks by an energy dispersive XRF (ED-XRF) spectrometer showed constant XRF intensity ratios of Hg (L(α))/Pb (L(α)). From these results, Hg in the ABS disk CRM was evaluated to be sufficiently stable for XRF analysis.

  12. Analysis of beverages for Hg, As, Pb, and Cd with a field portable X-ray fluorescence analyzer.

    PubMed

    Anderson, David L

    2010-01-01

    Analytical capabilities of a handheld X-ray tube analyzer for analysis of beverages were evaluated. Sets of standard solutions for the elements Hg, As, Pb, and Cd were prepared with mass fractions up to 5000 mg/kg. A thirst quencher beverage was spiked with these elements up to mass fractions of 2500 mg/kg. Portions of these solutions were placed in standard X-ray fluorescence (XRF) cells, as well as the original container, and analyzed by using a field portable Innov-X alpha-6000s XRF tube-type analyzer. Uncorrected analyzer output usually yielded qualitative or semiquantitative results for the spiked beverages in X-ray cells. Average correction factors applied to analyzer output yielded accurate (in terms of z-scores) quantitative results for As above 20 mg/kg and qualitative or semiquantitative results for the other elements. Weighted quadratic fit calibrations provided accurate quantitative or semiquantitative results for all elements at levels above 20 mg/kg. The instrument's preset X-ray overlap correction algorithm worked well for the beverage spiked with all four elements. Spiked beverages analyzed through the wall of the original polyethylene terephthalate container produced accurate results within measurement uncertainties after application of "container wall" correction factors.

  13. Advances in the detection of as in environmental samples using low energy X-ray fluorescence in a scanning transmission X-ray microscope: arsenic immobilization by an Fe(II)-oxidizing freshwater bacteria.

    PubMed

    Hitchcock, A P; Obst, M; Wang, J; Lu, Y S; Tyliszczak, T

    2012-03-01

    Speciation and quantitative mapping of elements, organic and inorganic compounds, and mineral phases in environmental samples at high spatial resolution is needed in many areas of geobiochemistry and environmental science. Scanning transmission X-ray microscopes (STXMs) provide a focused beam which can interrogate samples at a fine spatial scale. Quantitative chemical information can be extracted using the transmitted and energy-resolved X-ray fluorescence channels simultaneously. Here we compare the relative merits of transmission and low-energy X-ray fluorescence detection of X-ray absorption for speciation and quantitative analysis of the spatial distribution of arsenic(V) within cell-mineral aggregates formed by Acidovorax sp. strain BoFeN1, an anaerobic nitrate-reducing Fe(II)-oxidizing β-proteobacteria isolated from the sediments of Lake Constance. This species is noted to be highly tolerant to high levels of As(V). Related, As-tolerant Acidovorax-strains have been found in As-contaminated groundwater wells in Bangladesh and Cambodia wherein they might influence the mobility of As by providing sorption sites which might have different properties as compared to chemically formed Fe-minerals. In addition to demonstrating the lower detection limits that are achieved with X-ray fluorescence relative to transmission detection in STXM, this study helps to gain insights into the mechanisms of As immobilization by biogenic Fe-mineral formation and to further the understanding of As-resistance of anaerobic Fe(II)-oxidizing bacteria.

  14. Correction method for the self-absorption effects in fluorescence extended X-ray absorption fine structure on multilayer samples.

    PubMed

    Li, Wen Bin; Yang, Xiao Yue; Zhu, Jing Tao; Tu, Yu Chun; Mu, Bao Zhong; Yu, Hai Sheng; Wei, Xiang Jun; Huang, Yu Ying; Wang, Zhan Shan

    2014-05-01

    A novel correction method for self-absorption effects is proposed for extended X-ray absorption fine structure (EXAFS) detected in the fluorescence mode on multilayer samples. The effects of refraction and multiple reflection at the interfaces are fully considered in this correction method. The correction is performed in k-space before any further data analysis, and it can be applied to single-layer or multilayer samples with flat surfaces and without thickness limit when the model parameters for the samples are known. The validity of this method is verified by the fluorescence EXAFS data collected for a Cr/C multilayer sample measured at different experimental geometries. PMID:24763646

  15. Plane polarized x-ray fluorescence system for the in vivo measurement of platinum in head and neck tumours

    NASA Astrophysics Data System (ADS)

    Ali, P. A.; Al-Hussany, A. F.; Bennett, C. A.; Hancock, D. A.; El-Sharkawi, A. M.

    1998-08-01

    A plane polarized x-ray fluorescence system based on an orthovoltage radiotherapy treatment unit, the Pantak DXT-300, has been developed and optimized to measure tumour platinum concentration. The platinum derives from platinum based chemotherapy agents, such as cisplatin and carboplatin used to treat tumours in the head and neck region. Photons from an x-ray tube are polarized by scattering through , and used to stimulate the emission of characteristic platinum x-rays from the tumour. Information about the drug in the tumour could be of use in establishing dose-response relationships, in order to optimize the treatment and reduce the toxicity of the drug. The performance of the system was optimized with respect to the applied x-ray tube voltage, the current and the filter material; the effect on the minimum detection limit (MDL) of the thickness of the overlying tissue surrounding the tumour was investigated in detail. The lowest MDL is achieved using 0.25 mm of tin filter and x-ray tube voltage of 220 kV. This is 5.6 ppm for a tumour surrounded with 20 mm of overlying tissue, a measurement time of 2000 s and an estimated skin dose of 3.0 mGy. This represents the most sensitive in vivo XRF system to date. We have embarked on a clinical pilot study to measure the platinum concentration in tumours of the head and neck, and expect initial results to be available in the near future.

  16. Combining mid infrared and total X-ray fluorescence spectroscopy for prediction of soil properties

    NASA Astrophysics Data System (ADS)

    Towett, Erick; Shepherd, Keith; Sila, Andrew; Aynekulu, Ermias; Cadisch, Georg

    2015-04-01

    Mid-infrared diffuse reflectance spectroscopy (MIR) can predict many soil properties but extractable nutrients are often predicted poorly. We evaluated the potential of MIR and total elemental analysis using total X-ray fluorescence spectroscopy (TXRF), both individually and combined, to predict results of conventional soil tests. Total multi-elemental analysis provides a fingerprint of soil mineralogy and could predict some soil properties and help improve MIR predictions. A set of 700 georeferenced soil samples associated with the Africa Soil Information Service (AfSIS) (www.africasoils.net) from 44 stratified randomly-located 100-km2 sentinel sites distributed across sub-Saharan Africa were analysed for physico-chemical composition using conventional reference methods, and compared to MIR and TXRF spectra using the Random Forests regression algorithm and an internal out-of-bag validation. MIR spectra resulted in good prediction models (R2 >0.80) for organic C and total N, Mehlich-3 Ca and Al, and pH. To test the combined spectroscopic approach, TXRF element concentration data was included as a property predictor along with the first derivative of MIR spectral data using the RF algorithm. Including TXRF did not improve prediction of these properties. TXRF was poorer (R2 0.86) as these elements are not directly determined with TXRF, however the variance explained is still quite high and may be attributable to TXRF signatures relating to mineralogy correlated with protection of soil organic matter. TXRF model for Mehlich-3 Al had excellent prediction capability explaining 81% of the observed variation in extractable Al content and was comparable to that of MIR (R2 = 0.86). However, models for pH and Mehlich-3 exchangeable Ca exhibited R2 values of 0.74 and 0.79 respectively and thus had moderate predictive accuracy, compared to MIR alone with R2 values of 0.82 and 0.84 respectively. Both MIR and TXRF methods predicted soil properties that relate to nutrient

  17. Evaluation of the uncertainties associated with in vivo X-ray fluorescence bone lead calibrations

    NASA Astrophysics Data System (ADS)

    Lodwick, Jeffrey C.

    An anthropometric leg phantom developed at the University of Cincinnati (UC) was used to evaluate the effects that changes in leg position and variation between subjects has on in vivo x-ray fluorescence (XRF) measurements of stable lead in bone. The changes in leg position that were evaluated include changes in source-phantom distance ranging between 0.0 mm and 30.0 mm and phantom rotation over 40 degrees. Source-phantom distance was determined to have a significant effect on XRF measurement results particularly at source-phantom distances greater than 10.0 mm. Rotation of the leg phantom through 40 degrees was determined to have no significant effect on XRF measurement results. Between subject factors that were evaluated include bone calcium content and overlying tissue thickness. Bone calcium content was determined to have a significant effect on XRF measurements when measuring lead in micrograms per gram bone material. However, if measurement results of micrograms of lead per gram calcium (or per gram bone mineral) is used the normalization method makes the change in calcium content not significant. Overlying tissue thickness was determined to have no significant effect on XRF measurement results with tissue thickness ranging between 5.7 and 11.62 mm. The UC leg phantom was modified to include a fibula bone phantom so that the effect that the fibula has on XRF measurement results could be evaluated. The fibula was determined to have no significant effect on XRF measurement results and in the future need not be incorporated into in vivo XRF calibration phantoms. A knee phantom was also developed for purposes of calibrations of in vivo XRF measurement of lead in the patella. XRF measurement results using this phantom were compared to results of XRF measurements made using the plaster-of-Paris (POP) phantoms. A significant difference was observed between the normalized count rates of the two phantom types when either micrograms of lead per gram of bone material or

  18. Identifying Objects via Encased X-Ray-Fluorescent Materials - the Bar Code Inside

    NASA Technical Reports Server (NTRS)

    Schramm, Harry F.; Kaiser, Bruce

    2005-01-01

    Systems for identifying objects by means of x-ray fluorescence (XRF) of encased labeling elements have been developed. The XRF spectra of objects so labeled would be analogous to the external bar code labels now used to track objects in everyday commerce. In conjunction with computer-based tracking systems, databases, and labeling conventions, the XRF labels could be used in essentially the same manner as that of bar codes to track inventories and to record and process commercial transactions. In addition, as summarized briefly below, embedded XRF labels could be used to verify the authenticity of products, thereby helping to deter counterfeiting and fraud. A system, as described above, is called an encased core product identification and authentication system (ECPIAS). The ECPIAS concept is a modified version of that of a related recently initiated commercial development of handheld XRF spectral scanners that would identify alloys or detect labeling elements deposited on the surfaces of objects. In contrast, an ECPIAS would utilize labeling elements encased within the objects of interest. The basic ECPIAS concept is best illustrated by means of an example of one of several potential applications: labeling of cultured pearls by labeling the seed particles implanted in oysters to grow the pearls. Each pearl farmer would be assigned a unique mixture of labeling elements that could be distinguished from the corresponding mixtures of other farmers. The mixture would be either incorporated into or applied to the surfaces of the seed prior to implantation in the oyster. If necessary, the labeled seed would be further coated to make it nontoxic to the oyster. After implantation, the growth of layers of mother of pearl on the seed would encase the XRF labels, making these labels integral, permanent parts of the pearls that could not be removed without destroying the pearls themselves. The XRF labels would be read by use of XRF scanners, the spectral data outputs of which

  19. Characterization of urban air pollution by total reflection X-ray fluorescence*1

    NASA Astrophysics Data System (ADS)

    Schmeling, Martina

    2004-08-01

    Besides photochemical smog, particulate air pollution is a constantly growing problem in urban areas. The particulate matter present in pollution events contains often toxic or health impacting elements and is responsible for low visibility, might be triggering respiratory diseases like asthma, and can play an important role in formation or duration of smog events. To characterize particulate pollution in two different cities, samples were taken during intensive field campaigns in Chicago, IL, in 2002 and Phoenix, AZ, in 2001. Both cities experience regularly photochemical smog events as well as particulate pollution, but show very different meteorological and topographical conditions. Therefore it is expected that the particulate composition varies significantly, providing information about different pollution forms. Sampling took place in both cases at elevated locations and had a temporal resolution of 1.5 h and 1 h, respectively. The samples were analyzed by total reflection X-ray fluorescence after digestion of the filter matrix. As expected the elemental composition of particulate matter varied between both cities substantially with Phoenix showing a higher abundance of crustal elements, and Chicago enrichment in anthropogenically produced ones. In both cities diurnal patterns were found, exerting maxima in the morning and minima in the early afternoon. The diurnal pattern was much more regularly and also more strongly pronounced in Phoenix. Phoenix's valley location permits for a more stable nocturnal boundary layer to build up during the night thus trapping particulates efficiently during this time, until mixing occurs in the early morning hours and the residual layer lifts. In Chicago, the diurnal variation was less extreme, but another pattern determines the situation with the lake breeze. The lake breeze corresponds to a shift in wind direction towards the east, i.e. from Lake Michigan during the late morning. It was found that certain elemental species

  20. Quantitative Chemical Analysis of Archaeological Slag Material Using Handheld X-ray Fluorescence Spectrometry.

    PubMed

    Scott, Rebecca B; Eekelers, Kim; Degryse, Patrick

    2016-01-01

    Handheld X-ray fluorescence spectrometry (XRF) has seen a dramatic increase in use for archaeological projects. The attraction of the technique is its portable and nondestructive nature. In many cases, the archaeological artefacts in question cannot be destructively sampled, or the piece itself cannot be sent to an analytical laboratory. One of the current research interests associated with the Sagalassos project is the study of the Roman iron industry. Previously exported iron slag and ore from the site and the surrounding area was subjected to laboratory chemical analyses. These indicated that different ores were being utilized in the production of iron in different periods. In order to further the project the slag material still in the site depot needed to be analyzed. However, recent legislative changes mean that materials can only be analyzed on-site. Since samples could not be taken and destructive chemical analysis was no longer feasible, a portable, nondestructive technique was required. Handheld XRF can easily provide qualitative data, but these data are only comparable to other handheld XRF qualitative data, from the same device. Quantitative data gathering is possible, but can be more problematic, particularly when the material in question is heterogeneous in nature. A calibration file was created using the manufacturer's software and "in-house" standards made from the pre-quantified samples of iron slag available in the laboratory. In order to make the calibration as robust as possible, the composition of the standards was analyzed statistically to determine which of these created bias and leverage for specific elements. These standards were then omitted from the calibration for that element. The calibration was tested in the laboratory using samples of iron slag previously analyzed with wet chemistry, and the results indicated that most sample analyses showed <30% error. Results with a >30% error were found in samples which contained very low or very

  1. Quantitative Chemical Analysis of Archaeological Slag Material Using Handheld X-ray Fluorescence Spectrometry.

    PubMed

    Scott, Rebecca B; Eekelers, Kim; Degryse, Patrick

    2016-01-01

    Handheld X-ray fluorescence spectrometry (XRF) has seen a dramatic increase in use for archaeological projects. The attraction of the technique is its portable and nondestructive nature. In many cases, the archaeological artefacts in question cannot be destructively sampled, or the piece itself cannot be sent to an analytical laboratory. One of the current research interests associated with the Sagalassos project is the study of the Roman iron industry. Previously exported iron slag and ore from the site and the surrounding area was subjected to laboratory chemical analyses. These indicated that different ores were being utilized in the production of iron in different periods. In order to further the project the slag material still in the site depot needed to be analyzed. However, recent legislative changes mean that materials can only be analyzed on-site. Since samples could not be taken and destructive chemical analysis was no longer feasible, a portable, nondestructive technique was required. Handheld XRF can easily provide qualitative data, but these data are only comparable to other handheld XRF qualitative data, from the same device. Quantitative data gathering is possible, but can be more problematic, particularly when the material in question is heterogeneous in nature. A calibration file was created using the manufacturer's software and "in-house" standards made from the pre-quantified samples of iron slag available in the laboratory. In order to make the calibration as robust as possible, the composition of the standards was analyzed statistically to determine which of these created bias and leverage for specific elements. These standards were then omitted from the calibration for that element. The calibration was tested in the laboratory using samples of iron slag previously analyzed with wet chemistry, and the results indicated that most sample analyses showed <30% error. Results with a >30% error were found in samples which contained very low or very

  2. X-RAY FLUORESCENCE ANALYSIS OF HANFORD LOW ACTIVITY WASTE SIMULANTS

    SciTech Connect

    Jurgensen, A; David Missimer, D; Ronny Rutherford, R

    2006-05-08

    Savannah River National Laboratory (SRNL) was requested to develop an x-ray fluorescence (XRF) spectrometry method for elemental characterization of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) pretreated low activity waste (LAW) stream to the LAW Vitrification Plant. The WTP is evaluating the potential for using XRF as a rapid turnaround technique to support LAW product compliance and glass former batching. The overall objective of this task was to develop XRF analytical methods that provide the rapid turnaround time (<8 hours) requested by the WTP, while providing sufficient accuracy and precision to determine waste composition variations. For Phase 1a, SRNL (1) evaluated, selected, and procured an XRF instrument for WTP installation, (2) investigated three XRF sample methods for preparing the LAW sub-sample for XRF analysis, and (3) initiated scoping studies on AN-105 (Envelope A) simulant to determine the instrument's capability, limitations, and optimum operating parameters. After preliminary method development on simulants and the completion of Phase 1a activities, SRNL received approval from WTP to begin Phase 1b activities with the objective of optimizing the XRF methodology. Three XRF sample methods used for preparing the LAW sub-sample for XRF analysis were studied: direct liquid analysis, dried spot, and fused glass. The direct liquid method was selected because its major advantage is that the LAW can be analyzed directly without any sample alteration that could bias the method accuracy. It also is the fastest preparation technique--a typical XRF measurement could be completed in < 1hr after sample delivery. Except for sodium, the method detection limits (MDLs) for the most important analytes in solution, the hold point elements, were achieved by this method. The XRF detection limits are generally adequate for glass former batching and product composition reporting, but may be inadequate for some species (Hg, Cd, and Ba) important to

  3. Spatially resolved micro-X-ray fluorescence and micro-X-ray absorption fine structure study of a fractured granite bore core following a radiotracer experiment

    NASA Astrophysics Data System (ADS)

    Denecke, Melissa A.; Brendebach, Boris; De Nolf, Wout; Falkenberg, Gerald; Janssens, Koen; Simon, Rolf

    2009-08-01

    Spatially resolved X-ray absorption and fluorescence investigation with a micrometer-scale resolution on actinide-containing samples provide information necessary for safety assessment of nuclear waste disposal. In this paper one example of such an experiment is presented. This example entails neptunium speciation in a fractured granite bore core from the Swedish Äspö Hard Rock Laboratory following a radiotracer experiment using µ-XAFS and µ-XRF. In order to probe micro-volumes below the surface in the granite samples and thereby avoid potential changes in the Np speciation during cutting of the bore core, a confocal irradiation-detection geometry is employed. µ-XAFS results for a selected granite bore core cross section with ~ 3 nmol Np/g reveal that Np, originally introduced as Np(V) in the tracer cocktail, is present in the granite in its reduced Np(IV) form. The Np(IV) is often present as particles, tens of µm in size. Elemental distribution maps show the tracer Np to be located in fissures and permeable channels not larger than 100 µm. The Np distribution appears often correlated with Zn also present in some fissures. We observe small granite fissures containing Fe (presumably Fe(II)), where we do not detect any Np. It is feasible that inflowing Np(V) has a shorter residence time in large fractures, while in the smaller fissures migration is slower, leading to longer residence times, i.e., reaction times, where it is reduced to less soluble Np(IV) and becomes thereby immobilized.

  4. Selenium Preferentially Accumulates in the Eye Lens Following Embryonic Exposure: A Confocal X-ray Fluorescence Imaging Study

    SciTech Connect

    Choudhury, Sanjukta; Thomas, Jith; Sylvain, Nicole J.; Ponomarenko, Olena; Gordon, Robert A.; Heald, Steve M.; Janz, David M.; Krone, Patrick H.; Coulthard, Ian; George, Graham N.; Pickering, Ingrid J.

    2015-02-17

    Maternal transfer of elevated selenium (Se) to offspring is an important route of Se exposure for fish in the natural environment. However, there is a lack of information on the tissue specific spatial distribution and speciation of Se in the early developmental stages of fish, which provide important information about Se toxicokinetics. The effect of maternal transfer of Se was studied by feeding adult zebrafish a Se-elevated or a control diet followed by collection of larvae from both groups. Novel confocal synchrotron-based techniques were used to investigate Se within intact preserved larvae. Confocal X-ray fluorescence imaging was used to compare Se distributions within specific planes of an intact larva from each of the two groups. The elevated Se treatment showed substantially higher Se levels than the control; Se preferentially accumulated to highest levels in the eye lens, with lower levels in the retina, yolk and other tissues. Confocal X-ray absorption spectroscopy was used to determine that the speciation of Se within the eye lens of the intact larva was a selenomethionine-like species. Preferential accumulation of Se in the eye lens may suggest a direct cause-and-effect relationship between exposure to elevated Se and Se-induced ocular impairments reported previously. This study illustrates the effectiveness of confocal X-ray fluorescence methods for investigating trace element distribution and speciation in intact biological specimens

  5. Investigation of high-resolution superconducting tunnel junction detectors for low-energy X-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Beckhoff, B.; Fliegauf, R.; Ulm, G.

    2003-04-01

    The energy resolution of conventional semiconductor detectors is insufficient for simultaneously separating the leading fluorescence lines of low Z and medium Z materials in the soft X-ray regime. It is therefore important to investigate alternative detection instruments offering higher energy resolution and evaluate their applicability to soft X-ray fluorescence (XRF) analysis. In this paper, various results of the characterization and evaluation of a cryogenic superconducting tunnel junction (STJ) detector, which was provided to the Physikalisch-Technische Bundesanstalt (PTB) by the Lawrence Livermore National Laboratory, are given with respect to both detector response functions and XRF. For this investigation, monochromatized undulator radiation of high spectral purity, available to the PTB X-ray radiometry laboratory at the electron storage ring BESSY II, was employed, by which it was possible to record the STJ response functions at various photon energies of interest ranging from 180 to 1600 eV. By scanning the effective detector area and the adjacent substrate and leads, relevant artefacts of the detector response were identified.

  6. On Photospheric Fluorescence and the Nature of the 17.62 Angstrom Feature in Solar X-ray Spectra

    NASA Technical Reports Server (NTRS)

    Drake, Jeremy J.; Swartz, Douglas A.; Beiersdorfer, Peter; Brown, Greg; Kahn, S.

    1999-01-01

    The identification of the emission line feature at 17.62 Angstroms in solar x-ray spectra is re-examined. Using a Monte Carlo technique, we compute a realistic theoretical upper limit to the observed Fe L-alpha photospheric fluorescent line strength caused by irradiation from an overlying corona. These calculations demonstrate that the photospheric Fe L-alpha characteristic line is much too weak to account for the observed 17.62 Angstrom line flux. Instead, we identify this line with the configuration interaction 2s2p3p2P-2s2p6 2S transition in Fe XVIII seen in Electron Beam Ion Trap spectra and predicted in earlier theoretical work on the Fe XVIII x-ray spectrum.

  7. Calculation of depth-dependent elemental concentration with X-ray fluorescence using a layered calibration method

    NASA Astrophysics Data System (ADS)

    Gherase, M. R.; Fleming, D. E. B.

    2011-05-01

    Depth-dependent elemental concentration can be assessed using either multiple-angle or confocal X-ray fluorescence (XRF) measurements. This work presents a different approach based on a layered calibration method. The depth-dependent elemental concentration was modeled as multiple layers of uniform elemental concentrations. The unknown elemental concentration in each layer can be calculated using a single-angle XRF measurement, layered calibration data, and a priori knowledge of the concentration behavior as a function of depth. The method was verified using a commercial portable X-ray spectrometer and four-layer stacks of polyester resin discs doped with various concentrations of arsenic. This approach is particularly suitable for quantitative in vivo measurements of arsenic and selenium concentrations in the human skin since minimal ionizing radiation exposure constrains the number of XRF measurements.

  8. Quantitative Analysis of Cations in Solutions Using ion Exchange Filter Paper by X-ray Fluorescence Spectrometry

    NASA Astrophysics Data System (ADS)

    Taketani, Y.; Fujimaki, H.

    2007-12-01

    The strong acid cation exchange filter, CP-1, were applied to X-ray fluorescence (XRF) for trace elements in aqueous solution. In this study, the objective elements were Cu, Zn, Pb, and Cd. The measurement of the X-ray intensity determined the optimum methods of XRF analyses using the CP-1 filter. The optimum area that sample solutions penetrated was inside the determining area. The proper material to underlay CP-1 filter was glass bead. The calibration curves that determined by this study calculated the limit values of determination. These values were 0.72 micro gram for Cu and Zn. The method of separation and concentration using the CP-1 filter enable the quantitative analyses of trace heavy metals easily.

  9. Investigation of molecular mechanisms of action of chelating drugs on protein-lipid model membranes by X-ray fluorescence

    SciTech Connect

    Novikova, N. N.; Zheludeva, S. I.; Koval'chuk, M. V.; Stepina, N. D.; Erko, A. I.; Yur'eva, E. A.

    2009-12-15

    Protein-lipid films based on the enzyme alkaline phosphatase were subjected to the action of chelating drugs, which are used for accelerating the removal of heavy metals from the human body, and the elemental composition of the resulting films was investigated. Total-reflection X-ray fluorescence measurements were performed at the Berlin Electron Storage Ring Company for Synchrotron Radiation (BESSY) in Germany. A comparative estimation of the protective effect of four drugs (EDTA, succimer, xydiphone, and mediphon) on membrane-bound enzymes damaged by lead ions was made. The changes in the elemental composition of the protein-lipid films caused by high doses of chelating drugs were investigated. It was shown that state-of-the-art X-ray techniques can, in principle, be used to develop new methods for the in vitro evaluation of the efficiency of drugs, providing differential data on their actions.

  10. Synchrotron X-ray fluorescence microscopy of gallium in bladder tissue following gallium maltolate administration during urinary tract infection.

    PubMed

    Ball, Katherine R; Sampieri, Francesca; Chirino, Manuel; Hamilton, Don L; Blyth, Robert I R; Sham, Tsun-Kong; Dowling, Patricia M; Thompson, Julie

    2013-11-01

    A mouse model of cystitis caused by uropathogenic Escherichia coli was used to study the distribution of gallium in bladder tissue following oral administration of gallium maltolate during urinary tract infection. The median concentration of gallium in homogenized bladder tissue from infected mice was 1.93 μg/g after daily administration of gallium maltolate for 5 days. Synchrotron X-ray fluorescence imaging and X-ray absorption spectroscopy of bladder sections confirmed that gallium arrived at the transitional epithelium, a potential site of uropathogenic E. coli infection. Gallium and iron were similarly but not identically distributed in the tissues, suggesting that at least some distribution mechanisms are not common between the two elements. The results of this study indicate that gallium maltolate may be a suitable candidate for further development as a novel antimicrobial therapy for urinary tract infections caused by uropathogenic E. coli.

  11. Synchrotron X-Ray Fluorescence Microscopy of Gallium in Bladder Tissue following Gallium Maltolate Administration during Urinary Tract Infection

    PubMed Central

    Sampieri, Francesca; Chirino, Manuel; Hamilton, Don L.; Blyth, Robert I. R.; Sham, Tsun-Kong; Dowling, Patricia M.; Thompson, Julie

    2013-01-01

    A mouse model of cystitis caused by uropathogenic Escherichia coli was used to study the distribution of gallium in bladder tissue following oral administration of gallium maltolate during urinary tract infection. The median concentration of gallium in homogenized bladder tissue from infected mice was 1.93 μg/g after daily administration of gallium maltolate for 5 days. Synchrotron X-ray fluorescence imaging and X-ray absorption spectroscopy of bladder sections confirmed that gallium arrived at the transitional epithelium, a potential site of uropathogenic E. coli infection. Gallium and iron were similarly but not identically distributed in the tissues, suggesting that at least some distribution mechanisms are not common between the two elements. The results of this study indicate that gallium maltolate may be a suitable candidate for further development as a novel antimicrobial therapy for urinary tract infections caused by uropathogenic E. coli. PMID:23877680

  12. In-situ Measurements of Colloid Transport and Retention Using Synchroton X-ray Fluorescence

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The physics regarding the retention and mobilization of colloids in saturated and unsaturated conditions remains poorly understood, partially due to the inability to measure colloid concentrations in-situ. In this study, we attached Cd+2 ions to clay colloids, and used synchrotron x-rays to cause th...

  13. A feasibility study to determine the potential of in vivo detection of gadolinium by x-ray fluorescence (XRF) following gadolinium-based contrast-enhanced MRI.

    PubMed

    Mostafaei, F; McNeill, F E; Chettle, D R; Noseworthy, M D

    2015-01-01

    The feasibility of using a (109)Cd γ-ray induced K x-ray fluorescence (K-XRF) system for the in vivo detection of gadolinium (Gd) in bone has been investigated. The K-XRF bone measurement system employs an array of four detectors, and is normally used for the non-invasive study of bone lead levels. The system was used to measure bone simulating phantoms doped with varying levels of gadolinium and fixed amounts of sodium (Na), chlorine (Cl) and calcium (Ca). The detection limits for bare bone phantoms, using a source of activity 0.17 GBq, were determined to be 3.9 ppm and 6.5 ppm (µg Gd per gram phantom) for the Kα1 and Kα2 Gd x-ray peaks, respectively. This leads to an overall detection limit of 3.3 ppm (µg Gd per gram phantom). Layers of plastic were used to simulate overlying soft tissue and this permitted prediction of a detection limit, using the current strength of our radioisotope source, of 6.1 ppm to 8.6 ppm (µg Gd per gram phantom) for fingers with 2-4 mm of overlying tissue. With a new source of activity 5 GBq, we predict that this system could achieve a detection limit of 4-5.6 µg Gd g(-1) Ca. This is within the range of levels (2-30 µg Gd g(-1) Ca) previously found in the bone of patients receiving Gd based contrast imaging agents. The technique is promising and warrants further investigation.

  14. Quantification and localization of trace metals in natural plancton using a synchrotron x-ray fluorescence microprobe.

    SciTech Connect

    Twining, B. S.; Baines, S. B.; Fisher, N. S.; Jacobsen, C.; Maser, J.; State Univ. of New York at Stony Brook

    2003-03-01

    The accumulation of trace metals by planktonic protists influences the growth of primary producers, metal biogeochemical cycling, and metal bioaccumulation in aquatic food chains. Despite their importance, unequivocal measurements of trace element concentrations in individual plankton cells have not been possible to date. We have used the 2-ID-E side-branch hard x-ray microprobe at the Advanced Photon Source to measure trace elements in individual marine plankton cells. This microprobe employs zoneplate optics to produce the sub-micron spatial resolution and low background fluorescence required to produce trace element maps of planktonic protist cells ranging in size from 3 to >50 {micro}m. We have developed preservation, rinsing, and mounting protocols that remove most of the salt from our marine samples, thus simplifying the identification of unknown cells and reducing high Cl-related background fluorescence. We have also developed spectral modeling techniques that account for the frequent overlap of adjacent fluorescence peaks and non-uniform detector response. Finally, we have used parallel soft x-ray transmission and epifluorescence microscopy images to estimate C normalized trace element concentrations, identify functional cell types (e.g., photosynthetic vs. non-photosynthetic), and correlate cell structures with spatial patterns in trace element fluorescence.

  15. Practical Considerations in Trace Element Analysis of Bone by Portable X-ray Fluorescence.

    PubMed

    Byrnes, Jennifer F; Bush, Peter J

    2016-07-01

    Forensic anthropologists are more often turning to nondestructive methods to assist with skeletal analyses, specifically for trace elemental analyses. Portable XRF (pXRF) instruments are versatile and are able to be used in diverse settings or for specimens of a shape and size that cannot be accommodated by laboratory-based instruments. Use of XRF requires knowledge of analysis parameters such as X-ray penetration and exit depth. Analysis depth was determined by examining pure elements through known thicknesses of equine bone slices. Correlation between the element's X-ray emission energy and the depth of reading was observed. Bone surfaces from a small unknown historic cemetery were analyzed before and after sanding of the periosteal surface to observe possible changes in XRF readings based on potential diagenesis. Results validate the pXRF device as a powerful and convenient instrument for nondestructive analysis, while highlighting limitations and considerations for the analysis of osseous materials. PMID:27093090

  16. Absolute Dating of Desert Varnish Using Portable X-Ray Fluorescence: Calibration and Testing

    NASA Astrophysics Data System (ADS)

    Pingitore, N. E.; Lytle, F. W.; Rowley, P. D.; Ferris, D. E.

    2004-12-01

    Desert varnish, also called rock varnish, is a thin biogenic layer of Mn-oxides, Fe-oxides, and clays that coats rock surfaces in arid and semi-arid regions. The mass of these metals in the varnish registers cumulative biologic activity over time and presents a possible dating mechanism, subject to appropriate assumptions and restrictions. We have used a portable x-ray fluorescence (PXRF) unit to measure Mn and Fe in numerous desert varnishes, both in the field and laboratory; the anticipated relationship between age and mass emerges from these data. Our attempts to refine the PXRF technique for absolute dating of desert varnish are confounded by the limited number of "dated" varnishes available to calibrate and test the method. Although there is no current method to directly ascertain the age of desert varnish, our search for "dated" varnishes has yielded three suitable types of test materials: (1) The ages of young basalt flows dated by various K/Ar radiometric techniques represent the maximum age of varnish developed on those surfaces. Such rocks are useful in the time range of perhaps 250,000 to 10,000 years; surface spalling with loss of varnish presents an upper time limit and difficulty in dating Holocene basalts presents a lower limit. Basalt flows typically provide horizontal surfaces that are ideal for PXRF measurements because, as a biogenic process, varnish development even at a single site varies with solar orientation. (2) Petroglyphs are the rock art that native peoples produced by pecking away varnish to expose fresh rock. This process restarts varnish development and the pecked surface gradually repatinates over time. At some locales, certain figures, symbols, and stylistic elements can be associated with an archaeological culture of known antiquity and duration, thus providing an age range for such glyphs. In the desert Southwest and Great Basin of the United States, appropriate glyphs are known from the present to at least 7000 years BP. Many of

  17. Laboratory Tests of a Handheld X-Ray Fluorescence Spectrometer: A Tool for Planetary Exploration

    NASA Astrophysics Data System (ADS)

    Young, K. E.; Evans, C. A.; Hodges, K.

    2011-12-01

    Maximizing the science return from a mission to another planetary surface involves the integration of science objectives with deployable technologies that enable the collection of data and samples. For long duration manned missions, it is likely that more samples will be collected than can be returned to Earth due to mass limits. A niche exists for technologies that help prioritize samples for return, provide data for future sample handling and curation, and characterization for samples that are not returned to Earth. To fill this niche, hardware and protocols for field instruments are currently being developed and evaluated at NASA Johnson Space Center and Arizona State University. Our goal is to develop an easily used, environmentally isolated facility as part of the astronaut surface habitat for preliminary sample characterization and down-selection. NASA has constructed a prototype, GeoLab, as a testbed for evaluating the scientific applicability and operational considerations of various analytical instruments. One instrument under evaluation is a small, portable x-ray fluorescence (XRF) spectrometer that can be also be used by astronaut explorers as part of their field gear while on scientific sorties, or on robotic field assistants. We report on preliminary usability tests for commercially available handheld XRF instruments. These instruments collect data by contacting the surface of a rock or sediment sample with an 8 mm-wide sensor window. Within 60 seconds, the devices can provide relatively precise data on the abundance of major and trace elements heavier than Na. Lab-based handheld XRF analyses of terrestrial and lunar samples, compared with those made with full-scale laboratory XRF systems, show good correlation, but we continue to investigate potential sources of error and the need for careful calibration with standards of known composition. Specifically, we use a suite of five terrestrial and five lunar basalts, all well characterized by conventional

  18. Pigments Elementary Chemical Composition Study of a Gainsborough Attributed Painting Employing a Portable X-Rays Fluorescence System

    NASA Astrophysics Data System (ADS)

    Appoloni, C. R.; Blonski, M. S.; Parreira, P. S.; Souza, L. A. C.

    2007-02-01

    The investigated painting, identified with the title "The woodman", is attributed to Thomas Gainsborough (XVIII century) and is under investigation at the Laboratory of Conservation Science (LACICOR), CECOR/EBA/UFMG. The measurements were carried out with a portable X-rays fluorescence (XRF) system constituted of a X-rays tube with Ag anode, a Si PIN — diode detector, nuclear electronic chain and a special designed mechanical system for the detector and X-ray tube positioning, that enables angular and XYZ movements of the excitation-detection system. The employed voltage and current intensity were 17 kV and 3 mA, respectively. The time of acquisition for each measurement was 500 s. XRF spectra were analyzed using the AXIL-WinQXAS software. Three measurements in each of the following regions of the painting were done: face, leaves, arm, sky and firewood. The carried out analysis indicated the following pigments: White (lead white and calcium sulfate, identified by the elements Pb, Ca and S), Blue (Prussian blue, identified by the key element Fe), Red (Vermilion, identified by the elements Hg and S) and Brown (mixture of Fe and Mn oxides, identified by the elements Fe and Mn). Elements belonging to modern pigments corresponding to the same colors were absent in the analyzed spectra.

  19. Determining the Conformation of an Adsorbed Br-PEG-Peptide by Long Period X-Ray Standing Wave Fluorescence

    SciTech Connect

    Crot, Carrie A.; Wu, Chunping; Schlossman, Mark L.; Trainor, Thomas P.; Eng, Peter.; Hanley, Luke

    2009-01-14

    Long-period X-ray standing wave fluorescence (XSW) and X-ray reflectivity techniques are employed to probe the conformation of a Br-poly(ethylene glycol) (PEG)-peptide adsorbate at the hydrated interface of a polystyrene substrate. The Br atom on this Br-PEG-peptide construct serves as a marker atom allowing determination by XSW of its position and distribution with respect to the adsorption surface with angstrom resolution. Adsorption occurs on native or ion-beam-modified polystyrene films that are spin-coated onto a Si substrate and display either nonpolar or polar surfaces, respectively. A compact, oriented monolayer of Br-PEG-peptide can be formed with the peptide end adsorbed onto the polar surface and the PEG end terminating with the Br tag extending into the aqueous phase. The 108-141 {angstrom} distance of the Br atom from the polystyrene surface in this oriented monolayer is similar to the estimated {approx}150 {angstrom} length of the extended Br-PEG-peptide. This Br-polystyrene distance depends on adsorption time and surface properties prior to adsorption. Incomplete multilayers form on the polar surface after sufficient adsorption time elapses. By contrast, adsorption onto the nonpolar surface is submonolayer, patchy, and highly disordered with an isotropic Br distribution. Overall, this combination of X-ray surface scattering techniques with a novel sample preparation strategy has several advantages as a real space probe of adsorbed or covalently bound biomolecules at the liquid-solid interface.

  20. Effect of powder sample granularity on fluorescent intensity and on thermal parameters in x-ray diffraction Rietveld analysis

    SciTech Connect

    Sparks, C.J.; Specht, E.D.; Ice, G.E. ); Kumar, R.; Zschack, P. ); Shiraishi, T. ); Hisatsune, K. )

    1991-01-01

    The effect of sample granularity on diffracted x-ray intensity was evaluated by measuring the 2{theta} dependence of x-ray fluorescence from various samples. Measurements were made in the symmetric geometry on samples ranging from single crystals to highly absorbing coarse powders. A characteristic shape for the absorption correction was observed. A demonstration of the sensitivity of Rietveld refined site occupation parameters is made on CuAu and Cu{sub 50}Au{sub 44}Ni{sub 6} alloys refined with and without granularity corrections. These alloys provide a good example of the effect of granularity due to their large linear x-ray absorption coefficients. Sample granularity and refined thermal parameters obtained from the Rietveld analysis were found to be correlated. Without a granularity correction, the refined thermal parameters are too low and can actually become negative in an attempt to compensate for granularity. A general shape for granularity correction can be included in refinement procedures. If no granularity correction is included, data should be restricted to above 30{degrees} 2{theta}, and thermal parameters should be ignored unless extreme precautions are taken to produce >5 {mu}m particles and high packing densities.