Sample records for radiological background levels

  1. Radiological assessment for bauxite mining and alumina refining.

    PubMed

    O'Connor, Brian H; Donoghue, A Michael; Manning, Timothy J H; Chesson, Barry J

    2013-01-01

    Two international benchmarks assess whether the mining and processing of ores containing Naturally Occurring Radioactive Material (NORM) require management under radiological regulations set by local jurisdictions. First, the 1 Bq/g benchmark for radionuclide head of chain activity concentration determines whether materials may be excluded from radiological regulation. Second, processes may be exempted from radiological regulation where occupational above-background exposures for members of the workforce do not exceed 1 mSv/year. This is also the upper-limit of exposure prescribed for members of the public. Alcoa of Australia Limited (Alcoa) has undertaken radiological evaluations of the mining and processing of bauxite from the Darling Range of Western Australia since the 1980s. Short-term monitoring projects have demonstrated that above-background exposures for workers do not exceed 1 mSv/year. A whole-of-year evaluation of above-background, occupational radiological doses for bauxite mining, alumina refining and residue operations was conducted during 2008/2009 as part of the Alcoa NORM Quality Assurance System (NQAS). The NQAS has been guided by publications from the International Commission on Radiological Protection (ICRP), the International Atomic Energy Agency (IAEA) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). The NQAS has been developed specifically in response to implementation of the Australian National Directory on Radiation Protection (NDRP). Positional monitoring was undertaken to increase the accuracy of natural background levels required for correction of occupational exposures. This is important in view of the small increments in exposure that occur in bauxite mining, alumina refining and residue operations relative to natural background. Positional monitoring was also undertaken to assess the potential for exposure in operating locations. Personal monitoring was undertaken to characterise exposures in Similar Exposure Groups (SEGs). The monitoring was undertaken over 12 months, to provide annual average assessments of above-background doses, thereby reducing temporal variations, especially for radon exposures. The monitoring program concentrated on gamma and radon exposures, rather than gross alpha exposures, as past studies have shown that gross alpha exposures from inhalable dust for most of the workforce are small in comparison to combined gamma and radon exposures. The natural background determinations were consistent with data in the literature for localities near Alcoa's mining, refining and residue operations in Western Australia, and also with UNSCEAR global data. Within the mining operations, there was further consistency between the above-background dose estimates and the local geochemistry, with slight elevation of dose levels in mining pits. Conservative estimates of above-background levels for the workforce have been made using an assumption of 100% occupancy (1920 hours per year) for the SEGs considered. Total incremental composite doses for individuals were clearly less than 1.0 mSv/year when gamma, radon progeny and gross alpha exposures were considered. This is despite the activity concentration of some materials being slightly higher than the benchmark of 1 Bq/g. The results are consistent with previous monitoring and demonstrate compliance with the 1 mSv/year exemption level within mining, refining and residue operations. These results will be of value to bauxite mines and alumina refineries elsewhere in the world.

  2. Radiological survey results at Building 22, Washington Navy Yard, Washington, D.C. (WNS001)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez, R.E.; Foley, R.D.; Uziel, M.S.

    A radiological survey was conducted in a portion of Building 22 at the Washington Navy Yard, Washington, D.C., on December 13, 1995. The survey was performed because former employees thought the area surveyed had some previous association with radioactive material. Employees remembered seeing radiation signs in the area and indicated that personnel occupying this area wore dosimeters. Two rooms in the survey area were surrounded by 1-ft-thick poured concrete walls and similar 6-in.-thick ceilings, and situated on top of a 1-ft-thick concrete slab, a configuration commonly used for radiation shielding in industrial radiography facilities. The radiological survey showed no gamma,more » beta-gamma, or alpha measurements above typical background levels. Low background radiation levels within the building indicated that even if low-level contamination were present beneath the tile, or larger amounts of contamination beneath the concrete slab, it poses no radiological hazard to building inhabitants under the present conditions. Further investigation may be required before drilling or demolition of the concrete slab. No photon radiation fields from sealed gamma sources or x-ray sources were detectable at the time of the survey. Gamma spectrometry analysis revealed no gamma emitters above typical background concentrations in one sediment and one water sample collected from a pit in the open bay area.« less

  3. 500 N. Michigan Ave, February 2016, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    The daily background level wasused in conjunction and compared to the levels equivalent to the USEPA action level for the Streetervillearea. The USEPA Action Level for Chicago’s Streeterville area is 7.1 picocuries per gram (pCi/g) totalradium.

  4. Lindsay Light Radiological Survey 160 N Columbus Drive Lower Level, March 2013

    EPA Pesticide Factsheets

    The background radiation levels in the area were recorded being between 3,000 and 3,500 cpm. Radiation levels at the surface of soil in the approximately 60 square-feet area interest were measured between 3,000 and 4,000 cpm.

  5. The value of medical student radiology education: A comparison of 1-week, 2-week, electives, and compulsories.

    PubMed

    Limchareon, Sornsupha; Kongprompsuk, Sutasinee

    2018-06-01

    Basic radiology interpretive skill is essential for all physicians. We developed a vertical type of radiology education, including basic radiology in the students' first clinical year and added the other 1-week or 2-week dedicated radiology rotation in the later clinical year. The objective of this study was to present a valuable radiology education to undergraduate medical students. At academic year 2014-2015, there were three different groups of the clinical-year students took a radiology rotation. All students completed the pretest of 30-image quiz at the first day of the course and the posttest of the same quiz at the last day of the course. The mean scores and the mean score changes of pretest and posttest were compared. A grade point average was used to determine the students' background characteristics. The relationships between students' background characteristics and the mean score changes were calculated. There were three groups of students including; 11 sixth-year elective students, 19 fifth-year compulsory students and 39 sixth-year compulsory students. The mean posttest score of all students were statistically significant greater than the mean pretest score (p < .001). For the students' years, time space or interest level had no significant effects on the improved score. Adding a 1-week dedicated radiology rotation to fifth- or sixth-year students after they finished the standard radiology course is beneficial to students. This type of vertical radiology curriculum is valuable and should be incorporated into formal medical school curricula. Copyright © 2017. Published by Elsevier Taiwan LLC.

  6. Spatial frequency characteristics at image decision-point locations for observers with different radiological backgrounds in lung nodule detection

    NASA Astrophysics Data System (ADS)

    Pietrzyk, Mariusz W.; Manning, David J.; Dix, Alan; Donovan, Tim

    2009-02-01

    Aim: The goal of the study is to determine the spatial frequency characteristics at locations in the image of overt and covert observers' decisions and find out if there are any similarities in different observers' groups: the same radiological experience group or the same accuracy scored level. Background: The radiological task is described as a visual searching decision making procedure involving visual perception and cognitive processing. Humans perceive the world through a number of spatial frequency channels, each sensitive to visual information carried by different spatial frequency ranges and orientations. Recent studies have shown that particular physical properties of local and global image-based elements are correlated with the performance and the level of experience of human observers in breast cancer and lung nodule detections. Neurological findings in visual perception were an inspiration for wavelet applications in vision research because the methodology tries to mimic the brain processing algorithms. Methods: The wavelet approach to the set of postero-anterior chest radiographs analysis has been used to characterize perceptual preferences observers with different levels of experience in the radiological task. Psychophysical methodology has been applied to track eye movements over the image, where particular ROIs related to the observers' fixation clusters has been analysed in the spaces frame by Daubechies functions. Results: Significance differences have been found between the spatial frequency characteristics at the location of different decisions.

  7. An aerial radiological survey of the Durango, Colorado uranium mill tailings site and surrounding area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hilton, L.K.

    1981-06-01

    An aerial radiological survey of Durango, Colorado, including the inactive uranium mill tailings piles located southwest of the town, was conducted during August 25--29, 1980, for the Department of Energy's Environmental and Safety Engineering Division. Areas of radiation exposure rates higher than the local background, which was about 15 microrentgens per hour ({mu}R/h), were observed directly over and to the south of the mill tailings piles, over a cemetery, and at two spots near the fairgrounds. The rapidly changing radiation exposure rates at the boundaries of the piles preclude accurate extrapolation of aerial radiological data to ground level exposure ratesmore » in their immediate vicinity. Estimated radiation exposure rates close to the piles, however, approached 30 times background, or about 450 {mu}R/h. Radiation exposure rates in a long area extending south from the tailings piles were about 25 {mu}R/h.« less

  8. Radiological Health Protection Issues Associated with Use of Active Detection Technology Systems for Detection of Radioactive Threat Materials

    DTIC Science & Technology

    2013-07-01

    detection system available will simply register events resulting from natural background radiation if a suitable source emission is not employed. The...random fluctuations in the natural background radiation level. Noise within the detection system can result from any of the various components that...Uritani et al., 1994). Nothing can generally be done to reduce or stabilize the amount of natural background radiation present for nonstationary

  9. An aerial radiological survey of the Durango, Colorado uranium mill tailings site and surrounding area. Date of survey: August 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hilton, L.K.

    1981-06-01

    An aerial radiological survey of Durango, Colorado, including the inactive uranium mill tailings piles located southwest of the town, was conducted during August 25--29, 1980, for the Department of Energy`s Environmental and Safety Engineering Division. Areas of radiation exposure rates higher than the local background, which was about 15 microrentgens per hour ({mu}R/h), were observed directly over and to the south of the mill tailings piles, over a cemetery, and at two spots near the fairgrounds. The rapidly changing radiation exposure rates at the boundaries of the piles preclude accurate extrapolation of aerial radiological data to ground level exposure ratesmore » in their immediate vicinity. Estimated radiation exposure rates close to the piles, however, approached 30 times background, or about 450 {mu}R/h. Radiation exposure rates in a long area extending south from the tailings piles were about 25 {mu}R/h.« less

  10. THE SM-1 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM, NOVEMBER 1954- DECEMBER 1960

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pressman, M; Pruett, P B

    1961-08-31

    BS>An environmental radiological monitoring program was conducted. All data obtained during a period extending from l 1/2 years prior to SM-1 reactor start-up through more than 3 years of reactor operation are summarized. The period extended from November 1954 through December 1960. Samples assayed for radioactivity include river water and bottom silt, SM-1 condenser cooling water, subsurface ground water, rain and snow, atmospheric particles obtained by air filtration and fallout, and biota. The report concludes that after more than 3 years of SM-1 reactor operation, no significant increase has been noted in the radiological background level in the Fort Belvoirmore » area.« less

  11. 641 N Michigan, September 2011, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    The unshielded field gamma measurements within the spoil matehals generated during the drilling processdid not exceed the respective threshold values previously stated and ranged from background levels of 4,000cpm to a maximum of about 8,000 cpm.

  12. REVIEW OF THE RADNET AIR MONITORING NETWORK UPGRADE AND EXPANSION

    EPA Science Inventory

    RadNet, formerly known as ERAMS, has been operating since the 1970's, monitoring environmental radiation across the country, supporting responses to radiological emergencies, and providing important information on background levels of radiation in the environment. The original ...

  13. Report to the National Park Service for Permit LAKE-2014-SCI-002

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burnley, Pamela C.

    The overall purpose of the study is to determine how to use existing geologic data to predict gamma-ray background levels as measured during aerial radiological surveys. Aerial radiological surveys have typically been for resource exploration purposes but are now also used for homeland security purposes and nuclear disaster assessment as well as determining the depth of snowpack. Foreknowledge of the background measured during aerial radiological survey will be valuable for all the above applications. The gamma-ray background comes from the rocks and soil within the first 30 cm of the earth’s surface in the area where the survey is beingmore » made. The background should therefore be predictable based on an understanding of the distribution and geochemistry of the rocks on the surface. We are using a combination of geologic maps, remote sensing imagery and geochemical data from existing databases and the scientific literature to develop a method for predicting gamma-ray backgrounds. As part of this project we have an opportunity to ground truth our technique along a survey calibration line near Lake Mojave that is used by the Remote Sensing Lab (RSL) of National Security Technologies, LLC (NSTec). RSL makes aerial measurements along this line on a regular basis, so the aerial background in the area is well known. By making ground-based measurements of the gamma-ray background and detailed observations of the geology of the ground surface as well as local topography we will have the data we need to make corrections to the models we build based on the remote sensing and geologic data. Our project involves collaborators from the Airborne Geophysics Section of the Geological Survey of Canada as well as from NSTec’s RSL. Findings« less

  14. RadMAP: The Radiological Multi-sensor Analysis Platform

    NASA Astrophysics Data System (ADS)

    Bandstra, Mark S.; Aucott, Timothy J.; Brubaker, Erik; Chivers, Daniel H.; Cooper, Reynold J.; Curtis, Joseph C.; Davis, John R.; Joshi, Tenzing H.; Kua, John; Meyer, Ross; Negut, Victor; Quinlan, Michael; Quiter, Brian J.; Srinivasan, Shreyas; Zakhor, Avideh; Zhang, Richard; Vetter, Kai

    2016-12-01

    The variability of gamma-ray and neutron background during the operation of a mobile detector system greatly limits the ability of the system to detect weak radiological and nuclear threats. The natural radiation background measured by a mobile detector system is the result of many factors, including the radioactivity of nearby materials, the geometric configuration of those materials and the system, the presence of absorbing materials, and atmospheric conditions. Background variations tend to be highly non-Poissonian, making it difficult to set robust detection thresholds using knowledge of the mean background rate alone. The Radiological Multi-sensor Analysis Platform (RadMAP) system is designed to allow the systematic study of natural radiological background variations and to serve as a development platform for emerging concepts in mobile radiation detection and imaging. To do this, RadMAP has been used to acquire extensive, systematic background measurements and correlated contextual data that can be used to test algorithms and detector modalities at low false alarm rates. By combining gamma-ray and neutron detector systems with data from contextual sensors, the system enables the fusion of data from multiple sensors into novel data products. The data are curated in a common format that allows for rapid querying across all sensors, creating detailed multi-sensor datasets that are used to study correlations between radiological and contextual data, and develop and test novel techniques in mobile detection and imaging. In this paper we will describe the instruments that comprise the RadMAP system, the effort to curate and provide access to multi-sensor data, and some initial results on the fusion of contextual and radiological data.

  15. Verification of Minimum Detectable Activity for Radiological Threat Source Search

    NASA Astrophysics Data System (ADS)

    Gardiner, Hannah; Myjak, Mitchell; Baciak, James; Detwiler, Rebecca; Seifert, Carolyn

    2015-10-01

    The Department of Homeland Security's Domestic Nuclear Detection Office is working to develop advanced technologies that will improve the ability to detect, localize, and identify radiological and nuclear sources from airborne platforms. The Airborne Radiological Enhanced-sensor System (ARES) program is developing advanced data fusion algorithms for analyzing data from a helicopter-mounted radiation detector. This detector platform provides a rapid, wide-area assessment of radiological conditions at ground level. The NSCRAD (Nuisance-rejection Spectral Comparison Ratios for Anomaly Detection) algorithm was developed to distinguish low-count sources of interest from benign naturally occurring radiation and irrelevant nuisance sources. It uses a number of broad, overlapping regions of interest to statistically compare each newly measured spectrum with the current estimate for the background to identify anomalies. We recently developed a method to estimate the minimum detectable activity (MDA) of NSCRAD in real time. We present this method here and report on the MDA verification using both laboratory measurements and simulated injects on measured backgrounds at or near the detection limits. This work is supported by the US Department of Homeland Security, Domestic Nuclear Detection Office, under competitively awarded contract/IAA HSHQDC-12-X-00376. This support does not constitute an express or implied endorsement on the part of the Gov't.

  16. Effects of ionizing radiation on wildlife: what knowledge have we gained between the Chernobyl and Fukushima accidents?

    PubMed

    Beresford, Nicholas A; Copplestone, David

    2011-07-01

    The recent events at the Fukushima Daiichi nuclear power plant in Japan have raised questions over the effects of radiation in the environment. This article considers what we have learned about the radiological consequences for the environment from the Chernobyl accident, Ukraine, in April 1986. The literature offers mixed opinions of the long-term impacts on wildlife close to the Chernobyl plant, with some articles reporting significant effects at very low dose rates (below natural background dose rate levels in, for example, the United Kingdom). The lack of agreement highlights the need for further research to establish whether current radiological protection criteria for wildlife are adequate (and to determine if there are any implications for human radiological protection). Copyright © 2011 SETAC.

  17. Nearest Neighbor Averaging and its Effect on the Critical Level and Minimum Detectable Concentration for Scanning Radiological Survey Instruments that Perform Facility Release Surveys.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fournier, Sean Donovan; Beall, Patrick S; Miller, Mark L

    2014-08-01

    Through the SNL New Mexico Small Business Assistance (NMSBA) program, several Sandia engineers worked with the Environmental Restoration Group (ERG) Inc. to verify and validate a novel algorithm used to determine the scanning Critical Level (L c ) and Minimum Detectable Concentration (MDC) (or Minimum Detectable Areal Activity) for the 102F scanning system. Through the use of Monte Carlo statistical simulations the algorithm mathematically demonstrates accuracy in determining the L c and MDC when a nearest-neighbor averaging (NNA) technique was used. To empirically validate this approach, SNL prepared several spiked sources and ran a test with the ERG 102F instrumentmore » on a bare concrete floor known to have no radiological contamination other than background naturally occurring radioactive material (NORM). The tests conclude that the NNA technique increases the sensitivity (decreases the L c and MDC) for high-density data maps that are obtained by scanning radiological survey instruments.« less

  18. Radiological features of experimental staphylococcal septic arthritis by micro computed tomography scan

    PubMed Central

    Fatima, Farah; Fei, Ying; Ali, Abukar; Mohammad, Majd; Erlandsson, Malin C.; Bokarewa, Maria I.; Nawaz, Muhammad; Valadi, Hadi; Na, Manli

    2017-01-01

    Background Permanent joint dysfunction due to bone destruction occurs in up to 50% of patients with septic arthritis. Recently, imaging technologies such as micro computed tomography (μCT) scan have been widely used for preclinical models of autoimmune joint disorders. However, the radiological features of septic arthritis in mice are still largely unknown. Methods NMRI mice were intravenously or intra-articularly inoculated with S. aureus Newman or LS-1 strain. The radiological and clinical signs of septic arthritis were followed for 10 days using μCT. We assessed the correlations between joint radiological changes and clinical signs, histological changes, and serum levels of cytokines. Results On days 5–7 after intravenous infection, bone destruction verified by μCT became evident in most of the infected joints. Radiological signs of bone destruction were dependent on the bacterial dose. The site most commonly affected by septic arthritis was the distal femur in knees. The bone destruction detected by μCT was positively correlated with histological changes in both local and hematogenous septic arthritis. The serum levels of IL-6 were significantly correlated with the severity of joint destruction. Conclusion μCT is a sensitive method for monitoring disease progression and determining the severity of bone destruction in a mouse model of septic arthritis. IL-6 may be used as a biomarker for bone destruction in septic arthritis. PMID:28152087

  19. Radiological survey of the inactive uranium-mill tailings at Durango, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haywood, F.F.; Perdue, P.T.; Shinpaugh, W.H.

    1980-03-01

    Results of a radiological survey of the inactive uranium-mill site at Durango, Colorado, conducted in April 1976, in cooperation with a team from Ford, Bacon and Davis Utah Inc., are presented together with descriptions of the instruments and techniques used to obtain the data. Direct above-ground gamma measurements and analysis of surface soil and sediment samples indicate movement of tailings from the piles toward Lightner Creek on the north and the Animas River on the east side of the piles. The concentration of /sup 226/Ra in the former raffinate pond area is only slightly above the background level. Two structuresmore » in Durango were found to contain high concentrations of airborne radon daughters, where tailings are known to have been utilized in construction. Near-background concentrations of radon daughters were found in a well-ventilated building close to the tailings.« less

  20. Preliminary post-emplacement safety analysis of the subseabed disposal of high-level nuclear waste

    NASA Astrophysics Data System (ADS)

    Kaplan, M. F.; Koplik, C. M.; Klett, R. D.

    1984-09-01

    The radiological hazard from the disposal of high-level nuclear waste within the deep ocean sediments is evaluated, on a preliminary basis, for locations in the central North Pacific and in the northwestern Atlantic. Radio-nuclide transport in the sediment and water column and by marine organisms is considered. Peak doses to an individual are approximately five orders of magnitude below background levels for both sites. Sensitivity analyses for most aspects of the post-emplacement systems models are included.

  1. Surface radiological investigations at two creek receiving runoff from White Wing Scrap Yard, Oak Ridge Reservation, Oak Ridge, Tennessee. Environmental Restoration Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uziel, M.S.; Tiner, P.F.; Williams, J.K.

    1994-02-01

    A surface radiological investigation was conducted intermittently from August 1992 July 1993 at two creeks receiving runoff from White Wing Scrap Yard. In this report, the two creeks (both unnamed tributaries of Bear Creek) are, referred to as the east creek and the west creek based on their respective locations relative to White Wing Scrap Yard. The radiological survey of accessible areas at the east creek revealed no detectable gamma exposure rates above typical background levels (8 to 12 {mu}R/h). The very slight elevations in gamma and beta-gamma levels found along the creek were generally associated with outcroppings of shalemore » and typical of naturally occurring radionuclides present in such material. No radiological anomalies were associated with an oily sheen observed on the water at three locations, three 55-gal metal drums in or near the creek, a small pile of metal debris near the creek, or several enclosures used in a 1969 study of animal excretion rates. Radionuclide analysis of three soil samples collected at the east creek demonstrated typical of {sup 60}Co, {sup 137}Cs, gross alpha activity, gross beta activity, and {sup 40}K.« less

  2. The Correlated Lecture Laboratory Series in Diagnostic Radiological Physics.

    ERIC Educational Resources Information Center

    Lamel, David A.; And Others

    This series in diagnostic radiological physics has been designed to provide the physics background requisite for the proper conduct of medical diagnostic x-ray examinations. The basic goal of the series is to bridge physics theory and radiological practice, achieved by combining pertinent lecture material with laboratory exercises that illustrate…

  3. Effects of Hospital Workers’ Friendship Networks on Job Stress

    PubMed Central

    Shin, Sung Yae; Lee, Sang Gyu

    2016-01-01

    Background This study attempted to identify the sources of job stress according to job position and investigate how friendship networks affect job stress. Methods Questionnaires based on The Health Professions Stress Inventory (HPSI) developed by Wolfgang experienced by healthcare providers were collected from 420 nurses, doctors and radiological technologists in two general hospitals in Korea by a multistage cluster sampling method. Multiple regression analysis was used to examine the effects of friendship networks on job stress after controlling for other factors. Results The severity of job stress differed according to level of job demands (p = .006); radiologic technologists experienced the least stress (45.4), nurses experienced moderate stress (52.4), and doctors experienced the most stress (53.6). Those with long-term friendships characterized by strong connections reported lower levels of stress than did those with weak ties to friends among nurses (1.3, p < .05) and radiological technologists (11.4, p < .01). The degree of cohesion among friends had a positive impact on the level of job stress experienced by nurses (8.2, p < .001) and radiological technologists (14.6, p < .1). Doctors who participated in workplace alumni meetings scored higher than those who did not. However, those who participated in alumni meetings outside the workplace showed the opposite tendency, scoring 9.4 (p < .05) lower than those who did not. The resources from their friendship network include both information and instrumental support. As most radiological technologists were male, their instrumental support positively affected their job stress (9.2, p < .05). Life information support was the primary positive contributor to control of nurses’ (4.1, p < .05), radiological technologists’ (8.0, p < .05) job stress. Conclusion The strength and density of such friendship networks were related to job stress. Life information support from their friendship network was the primary positive contributor to control of job stress. PMID:26900945

  4. Strategic planning in radiology.

    PubMed

    Gill, Ileana E; Ondategui-Parra, Silvia; Nathanson, Eric; Seiferth, Jeremy; Ros, Pablo R

    2005-04-01

    As radiology continues to evolve and grow, radiologists must be concerned with preparing radiology for the future. Decisions in capital investments, mergers, outpatient diagnostic clinics, and payment and liability issues will require practicing radiologists to develop and follow up managerial, interpersonal, and learning skills that were not as necessary in the past. To become adept in the new radiology environment and be able to manage change and deal with difficult decisions, radiologists need to acquire a background in strategy.

  5. Undergraduate radiology education in private and public teaching hospitals in Karachi, Pakistan: teaching duties, methodologies, and rewards

    PubMed Central

    Nadeem, Naila; Khawaja, Ranish Deedar Ali; Beg, Madiha; Naeem, Muhammad; Majid, Zain

    2013-01-01

    Background In an integrated method of education, medical students are introduced to radiology in their preclinical years. However, no study has been conducted in Pakistan to demonstrate an academic framework of medical radiology education at an undergraduate level. Therefore, we aimed to document and compare the current level of teaching duties, teaching methodologies, and teaching rewards among radiologists and residents in private and public teaching hospitals in Karachi, Pakistan. Methods A survey was conducted among 121 radiologists and residents in two private and two public teaching hospitals in Karachi, Pakistan. Radiologists who were nationally registered with the Pakistan Medical and Dental Council either part-time or full-time were included. Radiology residents and fellows who were nationally registered with the Pakistan Medical and Dental Council were also included. Self-administered questionnaires addressing teaching duties, methods, and rewards were collected from 95 participants. Results The overall response rate was 78.51% (95/121). All of the radiologists were involved in teaching residents and medical students, but only 36% reported formal training in teaching skills. Although most of the respondents (76%) agreed that medical students appeared enthusiastic about learning radiology, the time spent on teaching medical students was less than five hours per week annually (82%). Only 37% of the respondents preferred dedicated clerkships over distributed clerkships (41%). The most common preferred teaching methodology overall was one-on-one interaction. Tutorials, teaching rounds, and problem-based learning sessions were less favored by radiologists than by residents. Teaching via radiology films (86%) was the most frequent mode of instruction. Salary (59%) was the most commonly cited teaching reward. The majority of respondents (88%) were not satisfied with their current level of teaching rewards. Conclusion All radiologists and residents working in an academic radiology department are involved in teaching undergraduate students at multiple levels. The most valued teaching methodology involves use of images, with one-on-one interaction between the trainer and trainee. The monetary reward for teaching is inbuilt into the salary. The methodology adopted for teaching purposes was significantly different between respondents from private hospitals and those from public teaching hospitals. Because of low satisfaction among the respondents, efforts should be made to provide satisfying teaching rewards. PMID:23745098

  6. Thermal-work strain in law enforcement personnel during chemical, biological, radiological, and nuclear (CBRN) training

    PubMed Central

    Yokota, M; Karis, A J; Tharion, W J

    2014-01-01

    Background: Thermal safety standards for the use of chemical, biological, radiological, and nuclear (CBRN) ensembles have been established for various US occupations, but not for law enforcement personnel. Objectives: We examined thermal strain levels of 30 male US law enforcement personnel who participated in CBRN field training in Arizona, Florida, and Massachusetts. Methods: Physiological responses were examined using unobtrusive heart rate (HR) monitors and a simple thermoregulatory model to predict core temperature (Tc) using HR and environment. Results: Thermal strain levels varied by environments, activity levels, and type of CBRN ensemble. Arizona and Florida volunteers working in hot-dry and hot-humid environment indicated high heat strain (predicted max Tc>38.5°C). The cool environment of Massachusetts reduced thermal strain although thermal strains were occasionally moderate. Conclusions: The non-invasive method of using physiological monitoring and thermoregulatory modeling could improve law enforcement mission to reduce the risk of heat illness or injury. PMID:24999847

  7. Case-oriented computer-based-training in radiology: concept, implementation and evaluation

    PubMed Central

    Dugas, Martin; Trumm, Christoph; Stäbler, Axel; Pander, Ernst; Hundt, Walter; Scheidler, Jurgen; Brüning, Roland; Helmberger, Thomas; Waggershauser, Tobias; Matzko, Matthias; Reiser, Maximillian

    2001-01-01

    Background Providing high-quality clinical cases is important for teaching radiology. We developed, implemented and evaluated a program for a university hospital to support this task. Methods The system was built with Intranet technology and connected to the Picture Archiving and Communications System (PACS). It contains cases for every user group from students to attendants and is structured according to the ACR-code (American College of Radiology) [2]. Each department member was given an individual account, could gather his teaching cases and put the completed cases into the common database. Results During 18 months 583 cases containing 4136 images involving all radiological techniques were compiled and 350 cases put into the common case repository. Workflow integration as well as individual interest influenced the personal efforts to participate but an increasing number of cases and minor modifications of the program improved user acceptance continuously. 101 students went through an evaluation which showed a high level of acceptance and a special interest in elaborate documentation. Conclusion Electronic access to reference cases for all department members anytime anywhere is feasible. Critical success factors are workflow integration, reliability, efficient retrieval strategies and incentives for case authoring. PMID:11686856

  8. Results of the radiological survey at the former ALCOA New Kensington Works, Pine and Ninth Streets, New Kensington, Pennsylvania (ANK002)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foley, R.D.; Brown, K.S.

    1992-10-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at the former ALCOA New Kensington Works, Pine and Ninth Streets, New Kensington, Pennsylvania. The survey was performed on November 12, 1991. The purpose of the survey was to determine whether the property was contaminated with radioactive residues, principally, as a result of work done for the Manhattan Engineer District in 1944. The survey included a gamma scan of three bays inside Building 18; measurement of direct alpha and beta-gamma levels in the same area; and collection of amore » dust sample for radionuclide analysis from the center of each bay. Results of the survey demonstrated no radionuclide concentrations or radiation measurements in excess of the DOE Formerly Utilized Sites Remedial Action Program guidelines for uranium. The radionuclide distributions were not significantly different from typical background levels in the Pittsburgh, Pennsylvania area.« less

  9. Study of natural radioactivity in Mansehra granite, Pakistan: environmental concerns.

    PubMed

    Qureshi, Aziz Ahmed; Jadoon, Ishtiaq Ahmed Khan; Wajid, Ali Abbas; Attique, Ahsan; Masood, Adil; Anees, Muhammad; Manzoor, Shahid; Waheed, Abdul; Tubassam, Aneela

    2014-03-01

    A part of Mansehra Granite was selected for the assessment of radiological hazards. The average activity concentrations of (226)Ra, (232)Th and (40)K were found to be 27.32, 50.07 and 953.10 Bq kg(-1), respectively. These values are in the median range when compared with the granites around the world. Radiological hazard indices and annual effective doses were estimated. All of these indices were found to be within the criterion limits except outdoor external dose (82.38 nGy h(-1)) and indoor external dose (156.04 nGy h(-1)), which are higher than the world's average background levels of 51 and 55 nGy h(-1), respectively. These values correspond to an average annual effective dose of 0.867 mSv y(-1), which is less than the criterion limit of 1 mSv y(-1) (ICRP-103). Some localities in the Mansehra city have annual effective dose higher than the limit of 1 mSv y(-1). Overall, the Mansehra Granite does not pose any significant radiological health hazard in the outdoor or indoor.

  10. Radiological incident preparedness: planning at the local level.

    PubMed

    Tan, Clive M; Barnett, Daniel J; Stolz, Adam J; Links, Jonathan M

    2011-03-01

    Radiological terrorism has been recognized as a probable scenario with high impact. Radiological preparedness planning at the federal and state levels has been encouraging, but translating complex doctrines into operational readiness at the local level has proved challenging. Based on the authors' experience with radiological response planning for the City of Baltimore, this article describes an integrated approach to municipal-level radiological emergency preparedness planning, provides information on resources that are useful for radiological preparedness planning, and recommends a step-by-step process toward developing the plan with relevant examples from the experience in Baltimore. Local governmental agencies constitute the first line of response and are critical to the success of the operation. This article is intended as a starting framework for local governmental efforts toward developing a response plan for radiological incidents in their communities.

  11. Real-Time Airborne Gamma-Ray Background Estimation Using NASVD with MLE and Radiation Transport for Calibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulisek, Jonathan A.; Schweppe, John E.; Stave, Sean C.

    2015-06-01

    Helicopter-mounted gamma-ray detectors can provide law enforcement officials the means to quickly and accurately detect, identify, and locate radiological threats over a wide geographical area. The ability to accurately distinguish radiological threat-generated gamma-ray signatures from background gamma radiation in real time is essential in order to realize this potential. This problem is non-trivial, especially in urban environments for which the background may change very rapidly during flight. This exacerbates the challenge of estimating background due to the poor counting statistics inherent in real-time airborne gamma-ray spectroscopy measurements. To address this, we have developed a new technique for real-time estimation ofmore » background gamma radiation from aerial measurements. This method is built upon on the noise-adjusted singular value decomposition (NASVD) technique that was previously developed for estimating the potassium (K), uranium (U), and thorium (T) concentrations in soil post-flight. The method can be calibrated using K, U, and T spectra determined from radiation transport simulations along with basis functions, which may be determined empirically by applying maximum likelihood estimation (MLE) to previously measured airborne gamma-ray spectra. The method was applied to both measured and simulated airborne gamma-ray spectra, with and without man-made radiological source injections. Compared to schemes based on simple averaging, this technique was less sensitive to background contamination from the injected man-made sources and may be particularly useful when the gamma-ray background frequently changes during the course of the flight.« less

  12. 75 FR 21006 - Town Hall Discussion With the Director of the Center for Devices and Radiological Health and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-22

    ... Radiological Health (CDRH) fiscal year (FY) 2010 priorities. In addition, FDA is interested in engaging in... information and discuss issues of importance to the medical device industry. CDRH is specifically interested... through Friday. SUPPLEMENTARY INFORMATION: I. Background CDRH has announced four priority areas of...

  13. 75 FR 40844 - Town Hall Discussion With the Director of the Center for Devices and Radiological Health and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-14

    ... Radiological Health (CDRH) Fiscal Year (FY) 2010 Priorities. In addition, FDA is interested in engaging in... and discuss issues of importance to the medical device industry. CDRH is specifically interested in... through Friday. SUPPLEMENTARY INFORMATION: I. Background CDRH has announced four priority areas of...

  14. Retrieval of Radiology Reports Citing Critical Findings with Disease-Specific Customization

    PubMed Central

    Lacson, Ronilda; Sugarbaker, Nathanael; Prevedello, Luciano M; Ivan, IP; Mar, Wendy; Andriole, Katherine P; Khorasani, Ramin

    2012-01-01

    Background: Communication of critical results from diagnostic procedures between caregivers is a Joint Commission national patient safety goal. Evaluating critical result communication often requires manual analysis of voluminous data, especially when reviewing unstructured textual results of radiologic findings. Information retrieval (IR) tools can facilitate this process by enabling automated retrieval of radiology reports that cite critical imaging findings. However, IR tools that have been developed for one disease or imaging modality often need substantial reconfiguration before they can be utilized for another disease entity. Purpose: This paper: 1) describes the process of customizing two Natural Language Processing (NLP) and Information Retrieval/Extraction applications – an open-source toolkit, A Nearly New Information Extraction system (ANNIE); and an application developed in-house, Information for Searching Content with an Ontology-Utilizing Toolkit (iSCOUT) – to illustrate the varying levels of customization required for different disease entities and; 2) evaluates each application’s performance in identifying and retrieving radiology reports citing critical imaging findings for three distinct diseases, pulmonary nodule, pneumothorax, and pulmonary embolus. Results: Both applications can be utilized for retrieval. iSCOUT and ANNIE had precision values between 0.90-0.98 and recall values between 0.79 and 0.94. ANNIE had consistently higher precision but required more customization. Conclusion: Understanding the customizations involved in utilizing NLP applications for various diseases will enable users to select the most suitable tool for specific tasks. PMID:22934127

  15. Evaluation of radiation exposure from diagnostic radiology examination; availability of final recommendations--FDA. Notice.

    PubMed

    1986-02-19

    The Food and Drug Administration (FDA) is announcing the availability of a document entitled "Recommendations for Evaluation of Radiation Exposure from Diagnostic Radiology Examinations". The recommendations, prepared by FDA's Center for Devices and Radiological Health (CDRH), encourage diagnostic radiology facilities to take voluntary action to: Become aware of the radiation levels experienced by patients undergoing the projections commonly given in the facility; compare their radiation levels to generally accepted levels for these projections; and bring the exposures back into line if their levels fall consistently outside these generally accepted levels.

  16. An Aerial Radiological Survey of the City of North Las Vegas (Downtown) and the Motor Speedway

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piotr Wasiolek

    2007-12-01

    As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey on December 11-12, 2007, with the purpose of mapping natural radiation background and locating any man-made radioactive sources. The survey covered 19.4 square miles (9.2 square miles over the downtown area of the City of North Las Vegas and 10.2 square miles over the Las Vegas Motor Speedway [LVMS]). The flight lines over the surveyed areas are presented in Figures 1 and 2. A total of four 2.5-hour-long flightsmore » were performed at an altitude of 150 ft above ground level (AGL) with 300 ft of flight line spacing. Water line and test line flights were conducted over the Lake Mead and Government Wash areas to ensure quality control of the data. The data were collected by the AMS data acquisition system-REDAR V using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data in the form of gamma energy spectra were collected continually (every second) over the course of the survey and were geo-referenced using a differential Global Positioning System. Collection of spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man-made radioisotopes sources. Spectral data can also be used to identify specific radioactive isotopes. As a courtesy service with the approval of the U.S. Department of Energy, National Nuclear Security Administration, Nevada Site Office, RSL-Nellis is providing this summary to the office of the Mayor of City of North Las Vegas and LVMS security along with the gross counts-based exposure rate and man-made counts maps.« less

  17. Reference levels of background radioactivity for beach sands and soils in İnebolu/Kastamonu-Turkey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnaz, Aslı, E-mail: akurnaz@kastamonu.edu.tr; Türkdoğan, Savaş, E-mail: savas-turk-dogan@hotmail.com; Hançerlioğulları, Aybaba, E-mail: aybaba@kastamonu.edu.tr

    This paper presents the measurement results of environmental radioactivity levels for İnebolu district (tourist area), Kastamonu-Turkey. The radioactivity concentrations of {sup 238}U, {sup 232}Th, {sup 40}K and the fission product {sup 137}Cs in soil samples collected from 13 region surroundings of study area and in 12 beach sand samples collected from along the coast of İnebolu were determined. To evaluate the radiological hazard of the natural radioactivity, based on the measured concentrations of these radionuclides, the mean absorbed gamma dose and the annual effective dose were evaluated separately, and found to be 112.90 nGy h-1 and 138.46 µSv y-1 for soilmore » samples and 75.19 nGy h-1 and 92.22 µSv y-1 for beach sand samples, respectively. The results show that İnebolu does not have high background.« less

  18. Reference levels of background radioactivity for beach sands and soils in İnebolu/Kastamonu-Turkey

    NASA Astrophysics Data System (ADS)

    Kurnaz, Aslı; Türkdoǧan, Savaş; Hançerlioǧulları, Aybaba; ćetiner, M. Atıf

    2016-03-01

    This paper presents the measurement results of environmental radioactivity levels for İnebolu district (tourist area), Kastamonu-Turkey. The radioactivity concentrations of 238U, 232Th, 40K and the fission product 137Cs in soil samples collected from 13 region surroundings of study area and in 12 beach sand samples collected from along the coast of İnebolu were determined. To evaluate the radiological hazard of the natural radioactivity, based on the measured concentrations of these radionuclides, the mean absorbed gamma dose and the annual effective dose were evaluated separately, and found to be 112.90 nGy h-1 and 138.46 µSv y-1 for soil samples and 75.19 nGy h-1 and 92.22 µSv y-1 for beach sand samples, respectively. The results show that İnebolu does not have high background.

  19. 75 FR 24718 - Town Hall Discussion With the Director of the Center for Devices and Radiological Health and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-05

    ... Devices and Radiological Health (CDRH) fiscal year (FY) 2010 priorities. In addition, FDA is interested in... importance to the medical device industry. CDRH is specifically interested in addressing the following.... Background CDRH has announced four priority areas of activity for FY 2010, each of which presents significant...

  20. Investigation of background radiation levels and geologic unit profiles in Durango, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Triplett, G.H.; Foutz, W.L.; Lesperance, L.R.

    1989-11-01

    As part of the Uranium Mill Tailings Remedial Action (UMTRA) Project, Oak Ridge National Laboratory (ORNL) has performed radiological surveys on 435 vicinity properties (VPs) in the Durango area. This study was undertaken to establish the background radiation levels and geologic unit profiles in the Durango VP area. During the months of May through June, 1986, extensive radiometric measurements and surface soil samples were collected in the Durango VP area by personnel from ORNL's Grand Junction Office. A majority of the Durango VP surveys were conducted at sites underlain by Quaternary alluvium, older Quaternary gravels, and Cretaceous Lewis and Mancosmore » shales. These four geologic units were selected to be evaluated. The data indicated no formation anomalies and established regional background radiation levels. Durango background radionuclide concentrations in surface soil were determined to be 20.3 {plus minus} 3.4 pCi/g for {sup 40}K, 1.6 {plus minus} 0.5 pCi/g for {sup 226}Ra, and 1.2 {plus minus} 0.3 pCi/g for {sup 232}Th. The Durango background gamma exposure rate was found to be 16.5 {plus minus} 1.3 {mu}R/h. Average gamma spectral count rate measurements for {sup 40}K, {sup 226}Ra and {sup 232}Th were determined to be 553, 150, and 98 counts per minute (cpm), respectively. Geologic unit profiles and Durango background radiation measurements are presented and compared with other areas. 19 refs., 15 figs., 5 tabs.« less

  1. An accurate laser radiometer for determining visible exposure times.

    PubMed

    Royston, D D

    1985-01-01

    A laser light radiometer has been developed for the Electro-Optics Branch of the Center for Devices and Radiological Health (CDRH). The radiometer measures direct laser radiation emitted in the visible spectrum. Based upon this measurement, the instrument's microprocessor automatically determines at what time duration the exposure to the measured laser radiation would exceed either the class I accessible emission limits of the Federal Performance Standard for laser products or the maximum permissible exposure limits of laser user safety standards. The instrument also features automatic background level compensation, pulse measurement capability, and self-diagnosis. Measurement of forward surface illumination levels preceding HpD photoradiation therapy is possible.

  2. Radiation in Yolo County

    NASA Astrophysics Data System (ADS)

    Dickie, H.; Colwell, K.

    2013-12-01

    In today's post-nuclear age, there are many man-made sources of radioactivity, in addition to the natural background we expect from cosmic and terrestrial origins. While all atoms possess unstable isotopes, there are few that are abundant enough, energetic enough, and have long enough half-lives to pose a signicant risk of ionizing radiation exposure. We hypothesize a decreasing relative radiation measurement (in detected counts per minute [CPM]) at nine locations that might pose occupational or environmental hazard: 1. A supermarket produce aisle (living tissue has high concentration of 40K) 2. A hospital (medical imaging uses X-rays and radioactive dyes) 3. The electronics section of a superstore (high voltage electronics have the potential to produce ionizing radiation) 4. An electrical transformer (similar reasons) 5. An antique store (some ceramics and glazes use radioisotopes that are now outlawed) 6. A gasoline pump (processing and terrestrial isotope contamination might leave a radioactive residue) 7. A fertilized eld (phosphate rock contains uranium and thorium, in addition to potassium) 8. A house (hopefully mild background, but potential radon contamination) 9. A school (should be radiologically neutral) We tested the hypothesis by measuring 100 minutes of counts on a self-assembled MightyOhmTM Geiger counter at each location. Our results show that contrary to the hypothesized ordering, the house was the most radiologically active. We present possible explanations for the observed radiation levels, as well as possible sources of measurement error, possible consequences of prolonged exposure to the measured levels, and suggestions for decreasing exposure and environmental impact.

  3. 76 FR 6476 - Town Hall Discussion With the Director of the Center for Devices and Radiological Health and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-04

    ... engage in a dialogue about issues of importance to FDA's Center for Devices and Radiological Health (CDRH...: I. Background In 2010, CDRH held three Town Hall meetings in Minneapolis, MN; Boston, MA; and Los... member of the public was invited to provide comments to or ask questions of CDRH participants. Due to the...

  4. 76 FR 41804 - Town Hall Discussion With the Director of the Center for Devices and Radiological Health and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-15

    ... dialogue about issues of importance to FDA's Center for Devices and Radiological Health (CDRH) and to... call 650- 589-3400 and request the group rate for the ``FDA/CDRH Town Hall Meeting'' block of rooms... between 9 a.m. and 4 p.m., Monday through Friday. SUPPLEMENTARY INFORMATION: I. Background In 2010, CDRH...

  5. 76 FR 13642 - Town Hall Discussion With the Director of the Center for Devices and Radiological Health and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-14

    ... dialogue about issues of importance to FDA's Center for Devices and Radiological Health (CDRH) and to... between 9 a.m. and 4 p.m., Monday through Friday. SUPPLEMENTARY INFORMATION: I. Background In 2010, CDRH... invited to provide comments to or ask questions of CDRH participants. We received positive feedback on...

  6. Role of conventional radiology and MRi defecography of pelvic floor hernias

    PubMed Central

    2013-01-01

    Background Purpose of the study is to define the role of conventional radiology and MRI in the evaluation of pelvic floor hernias in female pelvic floor disorders. Methods A MEDLINE and PubMed search was performed for journals before March 2013 with MeSH major terms 'MR Defecography' and 'pelvic floor hernias'. Results The prevalence of pelvic floor hernias at conventional radiology was higher if compared with that at MRI. Concerning the hernia content, there were significantly more enteroceles and sigmoidoceles on conventional radiology than on MRI, whereas, in relation to the hernia development modalities, the prevalence of elytroceles, edroceles, and Douglas' hernias at conventional radiology was significantly higher than that at MRI. Conclusions MRI shows lower sensitivity than conventional radiology in the detection of pelvic floor hernias development. The less-invasive MRI may have a role in a better evaluation of the entire pelvic anatomy and pelvic organ interaction especially in patients with multicompartmental defects, planned for surgery. PMID:24267789

  7. End-stage coxarthrosis and gonarthrosis. Aetiology, clinical patterns and radiological features of idiopathic osteoarthritis.

    PubMed

    Chitnavis, J; Sinsheimer, J S; Suchard, M A; Clipsham, K; Carr, A J

    2000-06-01

    To determine and compare the aetiological background, clinical patterns and radiological features of idiopathic osteoarthritis (OA) of the hip and the knee warranting arthroplasty. A total of 402 Caucasians consecutively undergoing total hip replacement (THR) or total knee replacement (TKR) for idiopathic OA at a major centre was surveyed. Previous joint injury was more common in the TKR group (P < 0.0001). However, both groups manifested a mixed occupational background, body mass indices similar to the general population and a predominance of females (F:M = 1.3-1.4:1). The TKR group had a significantly younger age of symptom onset (56 yr) than the THR group (61 yr) but both groups had a tendency to bilateral arthroplasty (33%), nodal involvement (54-59%), a significant excess of right-sided replacements (1.8:1, THR; 2.2:1, TKR) and similar levels of pre-operative pain and disability. Up to 40% of hips manifested acetabular dysplasia and 10% possible previous slipped upper femoral epiphyses. Eighty-five per cent with end-stage coxarthrosis or gonarthrosis had an identical pattern of radiographic disease contralaterally. Our data suggest the importance of a constitutional tendency to idiopathic, end-stage OA, a disorder traditionally associated with environmental factors leading to 'wear and tear'.

  8. Characterization of Change and Significance for Clinical Findings in Radiology Reports Through Natural Language Processing.

    PubMed

    Hassanpour, Saeed; Bay, Graham; Langlotz, Curtis P

    2017-06-01

    We built a natural language processing (NLP) method to automatically extract clinical findings in radiology reports and characterize their level of change and significance according to a radiology-specific information model. We utilized a combination of machine learning and rule-based approaches for this purpose. Our method is unique in capturing different features and levels of abstractions at surface, entity, and discourse levels in text analysis. This combination has enabled us to recognize the underlying semantics of radiology report narratives for this task. We evaluated our method on radiology reports from four major healthcare organizations. Our evaluation showed the efficacy of our method in highlighting important changes (accuracy 99.2%, precision 96.3%, recall 93.5%, and F1 score 94.7%) and identifying significant observations (accuracy 75.8%, precision 75.2%, recall 75.7%, and F1 score 75.3%) to characterize radiology reports. This method can help clinicians quickly understand the key observations in radiology reports and facilitate clinical decision support, review prioritization, and disease surveillance.

  9. Survey of UK radiology trainees in the aftermath of ‘Modernising Medical Careers’

    PubMed Central

    2012-01-01

    Background Following implementation of Modernising Medical Careers (MMC) in the UK, potential radiology trainees must decide on their career and apply sooner than ever before. We aimed to determine whether current trainees were sufficiently informed to make an earlier career decision by comparing the early radiology experiences of Traditional and Foundation Trainees. Methods 344 radiology trainees were appointed through MMC in 2007/08. This cohort was surveyed online. Results Response rate was 174/344 (51%). Traditional Trainees made their career decision 2.6 years after graduation compared with 1.2 years for Foundation Trainees (57/167, 34%). Nearly half of responders (79/169, 47%) experienced no formal radiology teaching as undergraduates. Most trainees regularly attended radiology meetings, spent time in a radiology department and/or performed radiology research. Many trainees received no career advice specific to radiology (69/163, 42%) at any point prior to entering the specialty; this includes both formal and informal advice. Junior doctor experiences were more frequently cited as influencing career choice (98/164, 60%). An earlier career decision was associated with; undergraduate radiology projects (-0.72 years, p = 0.018), career advice (-0.63 years, p = 0.009) and regular attendance at radiology meetings (-0.65 years, p = 0.014). Conclusion Early experience of radiology enables trainees to make an earlier career decision, however current radiology trainees were not always afforded relevant experiences prior to entering training. Radiologists need to be more proactive in encouraging the next generation of trainees. PMID:23031228

  10. An Aerial Radiological Survey of the Las Vegas Strip and Adjacent Areas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wasiolek, Piotr

    2009-02-01

    As proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory–Nellis (RSL-Nellis) conducted an aerial radiological survey of the Las Vegas Strip and adjacent areas on December 29, 2008. This survey was one of the bi-annual surveys carried in support of the city of Las Vegas Police Department (LVPD) before significant events on the Las Vegas Strip: e.g., the annual New Year’s Eve and July Fourth celebrations. The AMS operation and appropriate law enforcement agencies selected this area as an appropriate urban location to exercise AMS capability for mappingmore » environmental radiation and searching for man-made radioactive sources. The surveys covered approximately 11 square miles. Each survey required a 2.5-hour-long flight, performed at an altitude of 300 ft above ground level (AGL) at a line spacing of 600 ft. Water line and test line flights are conducted over the Lake Mead and Government Wash areas to determine the non-terrestrial background contributed by aircraft, radon, and cosmic activity, and to determine the altitude-dependent air mass correction. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2" x 4" x 16" sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Gamma energy spectral data were collected second-by-second over the survey area. This spectral data allows the system to distinguish between natural terrestrial background contributions and man-made radioisotope contributions. Spectral data can also be used to identify specific man-made radioactive isotopes. Data geo-locations were determined with a Real-Time Differential Global Positioning System (RDGPS).« less

  11. Low background screening capability in the UK

    NASA Astrophysics Data System (ADS)

    Ghag, Chamkaur

    2015-08-01

    Low background rare event searches in underground laboratories seeking observation of direct dark matter interactions or neutrino-less double beta decay have the potential to profoundly advance our understanding of the physical universe. Successful results from these experiments depend critically on construction from extremely radiologically clean materials and accurate knowledge of subsequent low levels of expected background. The experiments must conduct comprehensive screening campaigns to reduce radioactivity from detector components, and these measurements also inform detailed characterisation and quantification of background sources and their impact, necessary to assign statistical significance to any potential discovery. To provide requisite sensitivity for material screening and characterisation in the UK to support our rare event search activities, we have re-developed our infrastructure to add ultra-low background capability across a range of complementary techniques that collectively allow complete radioactivity measurements. Ultra-low background HPGe and BEGe detectors have been installed at the Boulby Underground Laboratory, itself undergoing substantial facility re-furbishment, to provide high sensitivity gamma spectroscopy in particular for measuring the uranium and thorium decay series products. Dedicated low-activity mass spectrometry instrumentation has been developed at UCL for part per trillion level contaminant identification to complement underground screening with direct U and Th measurements, and meet throughput demands. Finally, radon emanation screening at UCL measures radon background inaccessible to gamma or mass spectrometry techniques. With this new capability the UK is delivering half of the radioactivity screening for the LZ dark matter search experiment.

  12. The quality and impact of computer supported collaborative learning (CSCL) in radiology case-based learning.

    PubMed

    Kourdioukova, Elena V; Verstraete, Koenraad L; Valcke, Martin

    2011-06-01

    The aim of this research was to explore (1) clinical years students' perceptions about radiology case-based learning within a computer supported collaborative learning (CSCL) setting, (2) an analysis of the collaborative learning process, and (3) the learning impact of collaborative work on the radiology cases. The first part of this study focuses on a more detailed analysis of a survey study about CSCL based case-based learning, set up in the context of a broader radiology curriculum innovation. The second part centers on a qualitative and quantitative analysis of 52 online collaborative learning discussions from 5th year and nearly graduating medical students. The collaborative work was based on 26 radiology cases regarding musculoskeletal radiology. The analysis of perceptions about collaborative learning on radiology cases reflects a rather neutral attitude that also does not differ significantly in students of different grade levels. Less advanced students are more positive about CSCL as compared to last year students. Outcome evaluation shows a significantly higher level of accuracy in identification of radiology key structures and in radiology diagnosis as well as in linking the radiological signs with available clinical information in nearly graduated students. No significant differences between different grade levels were found in accuracy of using medical terminology. Students appreciate computer supported collaborative learning settings when tackling radiology case-based learning. Scripted computer supported collaborative learning groups proved to be useful for both 5th and 7th year students in view of developing components of their radiology diagnostic approaches. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  13. An indicator device for monitoring of room illuminance level in the radiological image viewing environment.

    PubMed

    Azlan, C A; Ng, K H; Anandan, S; Nizam, M S

    2006-09-01

    Illuminance level in the softcopy image viewing room is a very important factor to optimize productivity in radiological diagnosis. In today's radiological environment, the illuminance measurements are normally done during the quality control procedure and performed annually. Although the room is equipped with dimmer switches, radiologists are not able to decide the level of illuminance according to the standards. The aim of this study is to develop a simple real-time illuminance detector system to assist the radiologists in deciding an adequate illuminance level during radiological image viewing. The system indicates illuminance in a very simple visual form by using light emitting diodes. By employing the device in the viewing room, illuminance level can be monitored and adjusted effectively.

  14. A survey of nurse staffing levels in interventional radiology units throughout the UK.

    PubMed

    Christie, A; Robertson, I

    2016-07-01

    To supplement previous surveys analysing provision of interventional radiology (IR), in-hours (IH) and out-of-hours (OOH), by specifically surveying the level of nursing support provided. A web-based questionnaire was distributed to all British Society of Interventional Radiology (BSIR) members. This addressed several aspects of radiology nursing support for IR procedures, both IH and OOH. Sixty percent of respondents indicated that they have a formal OOH service. Of these, all have a dedicated nursing rota, with the vast majority operating with one nurse. IH, 77% of respondents always have a scrubbed nurse assistant, but this reduces to 40% OOH. IH, 4% never have a scrubbed radiology nurse assistant, which rises to 25% OOH. IH, 75% of respondents always have a radiology nurse dedicated to patient monitoring, but this reduces to 20% OOH. IH, 3% never have a radiology nurse dedicated to patient monitoring, which rises to 42% OOH. A significant disparity exists in the level of IR nursing support between IH and OOH. The majority of sites provide a single nurse with ad hoc additional support. This is potentially putting patients at increased risk. Radiology nurses are integral to the safe and sustainable provision of IR OOH services and a greater focus is required to ensure adequate and safe staffing levels for 24/7 IR services. Copyright © 2016. Published by Elsevier Ltd.

  15. Radiological and microwave Protection at NRL, January - December 1983

    DTIC Science & Technology

    1984-06-27

    reduced to background. 18 Surveys with TLD badges were made on pulsed electron beam machines in Buildings 101 and A68 throughout the year. The Gamble...calibration of radiation dosimetry systems required by the Laboratory’s radiological safety program, or by other Laboratory or Navy groups. The Section...provides consultation and assistance on dosimetry problems to the Staff, Laboratory, and Navy. The Section maintains and calibrates fixed-field radiac

  16. Biomarkers of Host Response Predict Primary End-Point Radiological Pneumonia in Tanzanian Children with Clinical Pneumonia: A Prospective Cohort Study

    PubMed Central

    Erdman, Laura K.; D’Acremont, Valérie; Hayford, Kyla; Kilowoko, Mary; Kyungu, Esther; Hongoa, Philipina; Alamo, Leonor; Streiner, David L.; Genton, Blaise; Kain, Kevin C.

    2015-01-01

    Background Diagnosing pediatric pneumonia is challenging in low-resource settings. The World Health Organization (WHO) has defined primary end-point radiological pneumonia for use in epidemiological and vaccine studies. However, radiography requires expertise and is often inaccessible. We hypothesized that plasma biomarkers of inflammation and endothelial activation may be useful surrogates for end-point pneumonia, and may provide insight into its biological significance. Methods We studied children with WHO-defined clinical pneumonia (n = 155) within a prospective cohort of 1,005 consecutive febrile children presenting to Tanzanian outpatient clinics. Based on x-ray findings, participants were categorized as primary end-point pneumonia (n = 30), other infiltrates (n = 31), or normal chest x-ray (n = 94). Plasma levels of 7 host response biomarkers at presentation were measured by ELISA. Associations between biomarker levels and radiological findings were assessed by Kruskal-Wallis test and multivariable logistic regression. Biomarker ability to predict radiological findings was evaluated using receiver operating characteristic curve analysis and Classification and Regression Tree analysis. Results Compared to children with normal x-ray, children with end-point pneumonia had significantly higher C-reactive protein, procalcitonin and Chitinase 3-like-1, while those with other infiltrates had elevated procalcitonin and von Willebrand Factor and decreased soluble Tie-2 and endoglin. Clinical variables were not predictive of radiological findings. Classification and Regression Tree analysis generated multi-marker models with improved performance over single markers for discriminating between groups. A model based on C-reactive protein and Chitinase 3-like-1 discriminated between end-point pneumonia and non-end-point pneumonia with 93.3% sensitivity (95% confidence interval 76.5–98.8), 80.8% specificity (72.6–87.1), positive likelihood ratio 4.9 (3.4–7.1), negative likelihood ratio 0.083 (0.022–0.32), and misclassification rate 0.20 (standard error 0.038). Conclusions In Tanzanian children with WHO-defined clinical pneumonia, combinations of host biomarkers distinguished between end-point pneumonia, other infiltrates, and normal chest x-ray, whereas clinical variables did not. These findings generate pathophysiological hypotheses and may have potential research and clinical utility. PMID:26366571

  17. A Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology

    PubMed Central

    Abrisham, Seyed Mohammad J.; Bouzarjomehri, Fathollah; Nafisi-Moghadam, Reza; Sobhan, Mohammad R.; Gadimi, Mahdie; Omidvar, Fereshte

    2017-01-01

    Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and precision of the system was confirmed according to the acceptance testing. The same procedure was used for 18 patients referred for lumbar spine digital radiology (overall 36 images). Results: Although radiation fields in the EOS were almost twice of that in digital radiology, and the average peak tube voltage (kVp), current supply to the tube (mA), and the average size and age of the patients referred for EOS imaging were greater than digital radiology, however, the average DAP in EOS was 1/5 of that in digital radiology system. Also, the average dose in the EOS was about 1/20 of that in digital radiology. Conclusion: The patient dose in EOS imaging system was lower in comparison with digital radiology (1/20). PMID:28656161

  18. Real-time airborne gamma-ray background estimation using NASVD with MLE and radiation transport for calibration

    NASA Astrophysics Data System (ADS)

    Kulisek, J. A.; Schweppe, J. E.; Stave, S. C.; Bernacki, B. E.; Jordan, D. V.; Stewart, T. N.; Seifert, C. E.; Kernan, W. J.

    2015-06-01

    Helicopter-mounted gamma-ray detectors can provide law enforcement officials the means to quickly and accurately detect, identify, and locate radiological threats over a wide geographical area. The ability to accurately distinguish radiological threat-generated gamma-ray signatures from background gamma radiation in real time is essential in order to realize this potential. This problem is non-trivial, especially in urban environments for which the background may change very rapidly during flight. This exacerbates the challenge of estimating background due to the poor counting statistics inherent in real-time airborne gamma-ray spectroscopy measurements. To address this challenge, we have developed a new technique for real-time estimation of background gamma radiation from aerial measurements without the need for human analyst intervention. The method can be calibrated using radiation transport simulations along with data from previous flights over areas for which the isotopic composition need not be known. Over the examined measured and simulated data sets, the method generated accurate background estimates even in the presence of a strong, 60Co source. The potential to track large and abrupt changes in background spectral shape and magnitude was demonstrated. The method can be implemented fairly easily in most modern computing languages and environments.

  19. RADIOLOGICAL HAZARD INDICES OF GRANITIC ROCKS USED FOR THE CONSTRUCTION OF BUILDINGS FROM NUBA MOUNTAINS SUDAN.

    PubMed

    Fadol, Nooreldin; Idriss, Hajo; Salih, Isam; Ragab, Nserdin A; Osman, Safa; Sam, Adam K

    2018-06-01

    This study was conducted to assess the level of radioactivity and the radiation hazards associated with granite rocks used for construction of buildings. The measurement of radioactivity content of the rock samples was performed with gamma-spectrometry equipped with Nal (TI) detector. From the results obtained in this study the average activity concentrations of 226Ra, 232Th and 40K were 20.64, 30.50 and 295.19 Bq kg-1, respectively. The absorbed dose rate in air at 1 m above ground level, the annual effective dose and the gamma index were determined with the aim to assess the possible radiological impact on inhabitants of dwellings built using such rocks. The mean value of the absorbed dose rate, the annual effective dose and the gamma index (Iγ) was 36.36 nGy h-1, 40.79 μSv y-1 and 0.51 μSv y-1, respectively. Radium equivalent activities, and external and internal hazard indices, were also calculated. These data indicated that the area of study lies within areas recognized as normal background radiation and the granite rocks are safe to be used as building material and other structural purposes.

  20. The Majorana Experiment:. a Straightforward Neutrino Mass Experiment Using the Double-Beta Decay of 76GE

    NASA Astrophysics Data System (ADS)

    Miley, H. S.

    2004-04-01

    The Majorana Experiment proposes to measure the effective mass of the electron neutrino to as low as 0.02 eV using well-tested technology. A half-life of about 4E27 y, corresponding to a mass range of [0.02 - 0.07] eV can be reached by operating 500 kg of germanium enriched to 86% in 76Ge deep underground. Radiological backgrounds of cosmogenic or primordial origin will be greatly reduced by ultra-low-background screening of detector, structural, and shielding materials, by chemical processing of materials, and by electronic rejection of multi-site events in the detector. Electronic background reduction is achieved with pulse-shape analysis, detector segmentation, and detector-to-detector coincidence rejection. Sensitivity calculations assuming worst-case germanium cosmogenic activation predict rapid growth in mass sensitivity (T1/2 at 90%CL) after the beginning of detector production: [0.08-0.28] eV at ~1 year, [0.04-0.14] eV at ~2.5 years, [0.03-0.10] eV at ~5 years, and [0.02 - 0.07] eV at ~10 years. The impact of primordial backgrounds in structural and electronic components is being studied at the 1 μBq/kg level, and appears to be controllable to below levels needed to attain these results.

  1. Radiation dose in the high background radiation area in Kerala, India.

    PubMed

    Christa, E P; Jojo, P J; Vaidyan, V K; Anilkumar, S; Eappen, K P

    2012-03-01

    A systematic radiological survey has been carried out in the region of high-background radiation area in Kollam district of Kerala to define the natural gamma-radiation levels. One hundred and forty seven soil samples from high-background radiation areas and five samples from normal background region were collected as per standard sampling procedures and were analysed for (238)U, (232)Th and (40)K by gamma-ray spectroscopy. External gamma dose rates at all sampling locations were also measured using a survey meter. The activities of (238)U, (232)Th and (40)K was found to vary from 17 to 3081 Bq kg(-1), 54 to 11976 Bq kg(-1) and BDL (67.4 Bq kg(-1)) to 216 Bq kg(-1), respectively, in the study area. Such heterogeneous distribution of radionuclides in the region may be attributed to the deposition phenomenon of beach sand soil in the region. Radium equivalent activities were found high in several locations. External gamma dose rates estimated from the levels of radionuclides in soil had a range from 49 to 9244 nGy h(-1). The result of gamma dose rate measured at the sampling sites using survey meter showed an excellent correlation with dose rates computed from the natural radionuclides estimated from the soil samples.

  2. The advantages, disadvantages, and policies for part-time radiologists: report of the ACR Commission on Human Resources.

    PubMed

    Harolds, Jay A; Coleman, Beverly G; Recht, Michael P; Bluth, Edward I

    2014-07-01

    The employment of part-time radiologists (PTRs) has both advantages and disadvantages in various practice settings. The authors examine the pros and cons of PTRs and review the literature regarding PTRs both within and outside the specialty of radiology. The complexity of this issue is manifested in our inability to reach consensus on many policy issues for PTRs. Nevertheless, this article should be helpful in offering an objective, nonbiased background to initiating a discussion on employing PTRs in various radiology practices. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marleau, Peter; Reyna, David

    In this work we investigate a method that confirms the operability of neutron detectors requiring neither radiological sources nor radiation-generating devices. This is desirable when radiological sources are not available, but confidence in the functionality of the instrument is required. The “source”, based on the production of neutrons in high-Z materials by muons, provides a tagged, low-background and consistent rate of neutrons that can be used to check the functionality of or calibrate a detector. Using a Monte Carlo guided optimization, an experimental apparatus was designed and built to evaluate the feasibility of this technique. Through a series of trialmore » measurements in a variety of locations we show that gated muon-induced neutrons appear to provide a consistent source of neutrons (35.9 ± 2.3 measured neutrons/10,000 muons in the instrument) under normal environmental variability (less than one statistical standard deviation for 10,000 muons) with a combined environmental + statistical uncertainty of ~18% for 10,000 muons. This is achieved in a single 21-22 minute measurement at sea level.« less

  4. Annual radiological environmental operating report: Browns Ferry Nuclear Plant, 1992. Operations Services/Technical Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-04-01

    This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant (BFN) in 1992. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiationmore » levels. Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. Small amounts of Co-60 and Cs-134 were found in sediment samples downstream from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public.« less

  5. Historical Radiological Event Monitoring

    EPA Pesticide Factsheets

    During and after radiological events EPA's RadNet monitors the environment for radiation. EPA monitored environmental radiation levels during and after Chernobyl, Fukushima and other international and domestic radiological incidents.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghag, Chamkaur

    Low background rare event searches in underground laboratories seeking observation of direct dark matter interactions or neutrino-less double beta decay have the potential to profoundly advance our understanding of the physical universe. Successful results from these experiments depend critically on construction from extremely radiologically clean materials and accurate knowledge of subsequent low levels of expected background. The experiments must conduct comprehensive screening campaigns to reduce radioactivity from detector components, and these measurements also inform detailed characterisation and quantification of background sources and their impact, necessary to assign statistical significance to any potential discovery. To provide requisite sensitivity for material screeningmore » and characterisation in the UK to support our rare event search activities, we have re-developed our infrastructure to add ultra-low background capability across a range of complementary techniques that collectively allow complete radioactivity measurements. Ultra-low background HPGe and BEGe detectors have been installed at the Boulby Underground Laboratory, itself undergoing substantial facility re-furbishment, to provide high sensitivity gamma spectroscopy in particular for measuring the uranium and thorium decay series products. Dedicated low-activity mass spectrometry instrumentation has been developed at UCL for part per trillion level contaminant identification to complement underground screening with direct U and Th measurements, and meet throughput demands. Finally, radon emanation screening at UCL measures radon background inaccessible to gamma or mass spectrometry techniques. With this new capability the UK is delivering half of the radioactivity screening for the LZ dark matter search experiment.« less

  7. Reducing DRIFT backgrounds with a submicron aluminized-mylar cathode

    NASA Astrophysics Data System (ADS)

    Battat, J. B. R.; Daw, E.; Dorofeev, A.; Ezeribe, A. C.; Fox, J. R.; Gauvreau, J.-L.; Gold, M.; Harmon, L.; Harton, J.; Lafler, R.; Landers, J.; Lauer, R. J.; Lee, E. R.; Loomba, D.; Lumnah, A.; Matthews, J.; Miller, E. H.; Mouton, F.; Murphy, A. St. J.; Paling, S. M.; Phan, N.; Sadler, S. W.; Scarff, A.; Schuckman, F. G.; Snowden-Ifft, D.; Spooner, N. J. C.; Walker, D.

    2015-09-01

    Background events in the DRIFT-IId dark matter detector, mimicking potential WIMP signals, are predominantly caused by alpha decays on the central cathode in which the alpha particle is completely or partially absorbed by the cathode material. We installed a 0.9 μm thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of cathode (wire, thin-film, and radiologically clean thin-film) with a focus on the ratio of background events to alpha decays. Two independent methods of measuring the absolute alpha decay rate are used to ensure an accurate result, and agree to within 10%. Using alpha range spectroscopy, we measure the radiologically cleanest cathode version to have a contamination of 3.3±0.1 ppt 234U and 73±2 ppb 238U. This cathode reduces the probability of producing an RPR from an alpha decay by a factor of 70±20 compared to the original stainless steel wire cathode. First results are presented from a texturized version of the cathode, intended to be even more transparent to alpha particles. These efforts, along with other background reduction measures, have resulted in a drop in the observed background rate from 500/day to 1/day. With the recent implementation of full-volume fiducialization, these remaining background events are identified, allowing for background-free operation.

  8. Extraforaminal Lumbar Interbody Fusion at the L5-S1 Level: Technical Considerations and Feasibility.

    PubMed

    Kurzbuch, Arthur Robert; Kaech, Denis; Baranowski, Pawel; Baranowska, Alicja; Recoules-Arche, Didier

    2017-09-01

    Background  Extraforaminal lumbar interbody fusion (ELIF) surgery is a muscle-sparing approach that allows the treatment of various degenerative spinal diseases. It is technical challenging to perform the ELIF approach at the L5-S1 level because the sacral ala obstructs the view of the intervertebral disk space. Methods  We reported earlier on the ELIF technique in which the intervertebral disk is targeted at an angle of 45 degrees relative to the midline. In this article we describe the technical process we developed to overcome the anatomic relation between the sacral ala and the intervertebral disk space L5-S1 that hinders the ELIF approach at this level. We then report in a retrospective analysis on the short-term clinical and radiologic outcome of 100 consecutive patients with degenerative L5-S1 pathologies who underwent ELIF surgery. Results  The L5-S1 ELIF approach could be realized in all patients. The short-term clinical outcome was evaluated 5 months after surgery: 92% of the patients were satisfied with their postoperative result; 8% had a poor result. Overall, 17% of the patients presented light radicular or low back pain not influencing their daily activity, and 82% of the patients working before surgery returned to work 3 to 7 months after surgery. The radiologic outcome was documented by computed tomography at 5 months after surgery and showed fusion in 99% of the patients. Lumbar magnetic resonance imaging performed in 5 patients at 6 months after surgery revealed the integrity of the paraspinal muscles. Conclusions  ELIF surgery at the L5-S1 level is technically feasible for various degenerative spinal diseases. Analysis of the clinical and radiologic data in a consecutive retrospective cohort of patients who underwent this surgical procedure showed a good short-term clinical outcome and fusion rate. Georg Thieme Verlag KG Stuttgart · New York.

  9. Natural radiation and its hazard in copper ore mines in Poland

    NASA Astrophysics Data System (ADS)

    Chau, Nguyen; Jodłowski, Paweł; Kalita, Stefan; Olko, Paweł; Chruściel, Edward; Maksymowicz, Adam; Waligórski, Michał; Bilski, Paweł; Budzanowski, Maciej

    2008-06-01

    The doses of gamma radiation, concentrations of radium isotopes in water and sediments, radon concentration and concentration of alpha potential energy of radon decay products in the copper ore mine and in the mining region in the vicinity of Lubin town in Poland are presented. These data served as a basis for the assessment of radiological hazard to the mine workers and general public. The results of this assessment indicate that radiological hazard in the region does not differ substantially from typical values associated with natural radiation background. The calculated average annual effective dose for copper miners is 1.48 mSv. In general, copper ore mines can be regarded as radiologically safe workplaces.

  10. [Management of acute and subacute clinical situations by interventional radiology: non-vascular interventions and treatment for hemoptysis].

    PubMed

    Nemes, Balázs; Doros, Attila

    2015-04-26

    Interventional radiology provides fast, straightforward and tolerable solutions for many medical problems including acute and subacute situations. Aspiration and drainage of fluid collections, biliary and endourologic interventions and gastrointestinal interventions are parts of non-vascular interventions. In addition, the authors discuss in detail interventional radiological treatment options in patients with hemoptysis. In acute cases interventions must be performed within 12-24 hours. For background, an everyday 24 hours service should be provided with well-trained personnel, high quality equipment and devices, and a reasonable financial reimbursement should be included, too. Multidisciplinary teamwork, consultations, consensus in indications and structured education should make these centers function most effectively.

  11. A model to determine payments associated with radiology procedures.

    PubMed

    Mabotuwana, Thusitha; Hall, Christopher S; Thomas, Shiby; Wald, Christoph

    2017-12-01

    Across the United States, there is a growing number of patients in Accountable Care Organizations and under risk contracts with commercial insurance. This is due to proliferation of new value-based payment models and care delivery reform efforts. In this context, the business model of radiology within a hospital or health system context is shifting from a primary profit-center to a cost-center with a goal of cost savings. Radiology departments need to increasingly understand how the transactional nature of the business relates to financial rewards. The main challenge with current reporting systems is that the information is presented only at an aggregated level, and often not broken down further, for instance, by type of exam. As such, the primary objective of this research is to provide better visibility into payments associated with individual radiology procedures in order to better calibrate expense/capital structure of the imaging enterprise to the actual revenue or value-add to the organization it belongs to. We propose a methodology that can be used to determine technical payments at a procedure level. We use a proportion based model to allocate payments to individual radiology procedures based on total charges (which also includes non-radiology related charges). Using a production dataset containing 424,250 radiology exams we calculated the overall average technical charge for Radiology to be $873.08 per procedure and the corresponding average payment to be $326.43 (range: $48.27 for XR and $2750.11 for PET/CT) resulting in an average payment percentage of 37.39% across all exams. We describe how charges associated with a procedure can be used to approximate technical payments at a more granular level with a focus on Radiology. The methodology is generalizable to approximate payment for other services as well. Understanding payments associated with each procedure can be useful during strategic practice planning. Charge-to-total charge ratio can be used to approximate radiology payments at a procedure level. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Radioactivity, radiological risk and metal pollution assessment in marine sediments from Calabrian selected areas, southern Italy

    NASA Astrophysics Data System (ADS)

    Caridi, F.; Messina, M.; Faggio, G.; Santangelo, S.; Messina, G.; Belmusto, G.

    2018-02-01

    The two most significant categories of physical and chemical pollutants in sediments (radionuclides and metals) were investigated in this article, in order to evaluate pollution levels in marine sediments from eight different selected sites of the Calabria region, south of Italy. In particular samples were analyzed to determine natural and anthropic radioactivity and metal concentrations, in order to assess any possible radiological hazard, the level of contamination and the possible anthropogenic impact in the investigated area. Activity concentrations of 226Ra, 232Th, 40K and 137Cs were measured by High Purity Germanium (HPGe) gamma spectrometry. The obtained results show that, for radium (in secular equilibrium with uranium), the specific activity ranges from ( 14 ± 1) Bq/kg dry weight (d.w.) to ( 54 ± 9) Bq/kg d.w.; for thorium, from ( 12 ± 1) Bq/kg d.w. to ( 83 ± 8) Bq/kg d.w.; for potassium, from ( 470 ± 20) Bq/kg d.w. to ( 1000 ± 70) Bq/kg d.w. and for cesium it is lower than the minimum detectable activity value. The absorbed gamma dose rate in air (D), the annual effective dose equivalent (AEDE) outdoor and the external hazard index ( H_ex) were calculated to evaluate any possible radiological risk, mainly due to the use of marine sediments for the beach nourishment. The results show low levels of radioactivity, thus discarding any significant radiological risk. Some metals (As, Cd, Cr tot, Hg, Ni, Pb, Cu, Zn, Mn and Fe), that could be released into the environment by both natural and anthropogenic sources, were investigated through inductively coupled plasma mass spectrometry (ICP-MS) measurements and compared with the limits set by the Italian Legislation, to assess any possible contamination. Experimental results show that they are much lower than the contamination threshold value, thus excluding their presence as pollutants. The degree of sediment contaminations were quantified using enrichment factor ( EF) and geoaccumulation index ( I geo) for some potential hazardous elements. Results show that EF and I geo values of As, Pb and Mn were the greatest among the studied metals. Data of this preliminary study could be helpful in the future to obtain background levels in marine sediments of the investigated region and to develop environmental regulatory frameworks.

  13. Emotional Wellness of Current Musculoskeletal Radiology Fellows.

    PubMed

    Porrino, Jack; Mulcahy, Michael J; Mulcahy, Hyojeong; Relyea-Chew, Annemarie; Chew, Felix S

    2017-06-01

    Burnout is a psychological syndrome composed of emotional exhaustion, depersonalization, and sense of lack of personal accomplishment, as a result of prolonged occupational stress. The purpose of our study was to determine the prevalence of burnout among current musculoskeletal radiology fellows and to explore causes of emotional stress. A 24-item survey was constructed on SurveyMonkey using the Maslach Burnout Inventory. We identified 82 musculoskeletal radiology fellowship programs. We recruited subjects indirectly through the program director or equivalent. Fifty-eight respondents (48 male, 10 female) identified themselves as current musculoskeletal radiology fellows and completed the survey. Comparison of the weighted subscale means in our data to the Maslach normative subscale thresholds for medical occupations indicates that musculoskeletal radiology fellows report relatively high levels of burnout with regard to lack of personal accomplishment and depersonalization, whereas emotional exhaustion levels in our sample are within the average range reported by Maslach. Although male musculoskeletal radiology fellows experience relatively high levels in two of the three dimensions of burnout (depersonalization and personal accomplishment), female musculoskeletal radiology fellows experience relatively high burnout across all three dimensions. Job market-related stress and the effort required providing care for dependents significantly affect personal accomplishment. Conversely, imbalances in the work-life relationship and feelings of powerlessness are significantly associated with depersonalization and emotional exhaustion. Musculoskeletal radiology fellows report relatively high levels of burnout. Because the consequences of burnout can be severe, early identification and appropriate intervention should be a priority. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  14. Quadrant III RFI draft report: Appendix B-I, Volume 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-12-01

    In order to determine the nature and extent of contamination at a RCRA site it is often necessary to investigate and characterize the chemical composition of the medium in question that represents background conditions. Background is defined as current conditions present at a site which are unaffected by past treatment, storage, or disposal of hazardous waste (OEPA, 1991). The background composition of soils at the Portsmouth Gaseous Diffusion Plant (PORTS) site was characterized for the purpose of comparing investigative soil data to a background standard for each metal on the Target Compound List/Target Analyte List and each radiological parameter ofmore » concern in this RFI. Characterization of background compositions with respect to organic parameters was not performed because the organic parameters in the TCL/TAL are not naturally occurring at the site and because the site is not located in a highly industrialized area nor downgradient from another unrelated hazardous waste site. Characterization of the background soil composition with respect to metals and radiological parameters was performed by collecting and analyzing soil boring and hand-auger samples in areas deemed unaffected by past treatment, storage, or disposal of hazardous waste. Criteria used in determining whether a soil sample location would be representative of the true background condition included: environmental history of the location, relation to Solid Waste Management Units (SWMU`s), prevailing wind direction, surface runoff direction, and ground-water flow direction.« less

  15. Quadrant III RFI draft report: Appendix B-I, Volume 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-12-01

    In order to determine the nature and extent of contamination at a RCRA site it is often necessary to investigate and characterize the chemical composition of the medium in question that represents background conditions. Background is defined as current conditions present at a site which are unaffected by past treatment, storage, or disposal of hazardous waste (OEPA, 1991). The background composition of soils at the Portsmouth Gaseous Diffusion Plant (PORTS) site was characterized for the purpose of comparing investigative soil data to a background standard for each metal on the Target Compound List/Target Analyte List and each radiological parameter ofmore » concern in this RFI. Characterization of background compositions with respect to organic parameters was not performed because the organic parameters in the TCL/TAL are not naturally occurring at the site and because the site is not located in a highly industrialized area nor downgradient from another unrelated hazardous waste site. Characterization of the background soil composition with respect to metals and radiological parameters was performed by collecting and analyzing soil boring and hand-auger samples in areas deemed unaffected by past treatment, storage, or disposal of hazardous waste. Criteria used in determining whether a soil sample location would be representative of the true background condition included: environmental history of the location, relation to Solid Waste Management Units (SWMU's), prevailing wind direction, surface runoff direction, and ground-water flow direction.« less

  16. A critical review of the readability of online patient education resources from RadiologyInfo.Org.

    PubMed

    Hansberry, David R; John, Ann; John, Elizabeth; Agarwal, Nitin; Gonzales, Sharon F; Baker, Stephen R

    2014-03-01

    Health consumers and their families rely on the Internet as a source of authoritative information regarding the procedures used to reach a diagnosis, effect treatment, and influence prognosis. In radiology, online materials can be a means by which to offer patients comprehensible explanations of the capabilities, the risks and rewards, and the techniques under our purview. Consequently, estimations of health literacy should take into account the reading level of the average American when composing and transmitting such information to the lay public without the mediation of a referring physician. In December 2012, patient education reports from the files of RadiologyInfo.org, a jointly sponsored website of the American College of Radiology and the Radiological Society of North America, were downloaded to assess their textual sophistication. All 138 patient education articles including the glossary were analyzed for their respective level of "readability" using the following 10 evaluative scales: Flesch Reading Ease, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook Grading, Coleman-Liau Index, Gunning Fog Index, New Dale-Chall scale, FORCAST, Fry graph, Raygor Readability Estimate, and New Fog Count. The 138 online patient education articles were written, on average, between the 10th and 14th grade levels, which exceeds both the American Medical Association and the National Institutes of Health recommendations that patient education resources be comprehensible to those who read no higher than the seventh grade level. Patients may accrue a greater benefit from written articles available on RadiologyInfo.org if the texts were revised to be in compliance with the National Institutes of Health and American Medical Association grade level recommendations. This could lead to a broadened appreciation of the capabilities of radiology's role in general and enhanced understanding of imaging techniques and their application to clinical practice.

  17. Ethnic and Gender Diversity in Radiology Fellowships.

    PubMed

    West, Derek L; Nguyen, HaiThuy

    2017-06-01

    The purpose of the study is to assess ethnic and gender diversity in US radiology fellowship programs from 2006 to 2013. Data for this study was obtained from Journal of the American Medical Association supplements publications from 2005 to 2006 to 2012-2013 (Gonzalez-Moreno, Innov Manag Policy Pract. 15(2):149, 2013; Nivet, Acad Med. 86(12):1487-9, 2011; Reede, Health Aff. 22(4):91-3, 2003; Chapman et al., Radiology 270(1):232-40, 2014; Getto, 2005; Rivo and Satcher, JAMA 270(9):1074-8, 1993; Schwartz et al., Otolaryngol Head Neck Surg. 149(1):71-6, 2013; Simon, Clin Orthop Relat Res. 360:253-9, 1999) and the US census 2010. For each year, Fisher's exact test was used to compare the percentage of women and under-represented minorities in each Accreditation Council for Graduate Medical Education (ACGME)-certified radiology fellowship to the percentage of women and under-represented minorities in (1) all ACGME-certified radiology fellowships combined, (2) radiology residents, (3) ACGME-certified fellows in all of medicine combined, (4) ACGME-certified residents in all of medicine combined, and (5) graduating medical students. Chi-Squared test was used to compare the percentage of women and under-represented minorities and the 2010 US census. p < 0.05 was used as indicator of significance. Interventional radiology and neuroradiology demonstrated the highest levels of disparities, compared to every level of medical education. Abdominal and musculoskeletal radiology fellowships demonstrated disparity patterns consistent with lack of female and URM medical graduates entering into radiology residency. All radiology fellowships demonstrated variable levels of gender and ethnic disparities. Outreach efforts, pipeline programs, and mentoring may be helpful in addressing this issue.

  18. Awareness of radiation protection and dose levels of imaging procedures among medical students, radiography students, and radiology residents at an academic hospital: Results of a comprehensive survey.

    PubMed

    Faggioni, Lorenzo; Paolicchi, Fabio; Bastiani, Luca; Guido, Davide; Caramella, Davide

    2017-01-01

    To evaluate the awareness of radiation protection issues and the knowledge of dose levels of imaging procedures among medical students, radiology residents, and radiography students at an academic hospital. A total of 159 young doctors and students (including 60 radiology residents, 56 medical students, and 43 radiography students) were issued a questionnaire consisting of 16 multiple choice questions divided into three separated sections (i.e., demographic data, awareness about radiation protection issues, and knowledge about radiation dose levels of common radiological examinations). Medical students claimed to have at least a good knowledge of radiation protection issues more frequently than radiology residents and radiography students (94.4% vs 55% and 35.7%, respectively; P<0.05), with no cases of perceived excellent knowledge among radiography students. However, the actual knowledge of essential radiation protection topics such as regulations, patient and tissue susceptibility to radiation damage, professional radiation risk and dose optimisation, as well as of radiation doses delivered by common radiological procedures was significantly worse among medical students than radiology residents and radiography students (P<0.05). Those latter significantly outperformed radiology residents as to knowledge of radiation protection issues (P<0.01). Overall, less than 50% of survey respondents correctly answered all questions of the survey. Radiology residents, radiography students and medical students have a limited awareness about radiation protection, with a specific gap of knowledge concerning real radiation doses of daily radiological examinations. Both undergraduate and postgraduate teaching needs to be effectively implemented with radiation safety courses. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Radiologic science students' perceptions of parental involvement.

    PubMed

    DuBose, Cheryl; Barymon, Deanna; Vanderford, Virginia; Hensley, Chad; Shaver, Gary

    2014-01-01

    A new generation of students is in the classroom, and they are not always alone. Helicopter parents, those who hover around the student and attempt to ease life's challenges, are accompanying the students to radiologic science programs across the nation. To determine radiologic science students' perception regarding their parents' level of involvement in their lives. A survey focused on student perceptions of parental involvement inside and outside of the academic setting was completed by 121 radiologic science students at 4 institutional settings. The analysis demonstrates statistically significant relationships between student sex, age, marital status, and perceived level of parental involvement. In addition, as financial support increases, students' perception of the level of parental involvement also increases. Radiologic science students want their parents to be involved in their higher education decisions. Research indicates that students with involved parents are more successful, and faculty should be prepared for increased parental involvement in the future. Radiologic science students perceive their parents to be involved in their academic careers. Ninety-five percent of respondents believe that the financial support of their parent or parents contributes to their academic success. Sixty-five percent of participants are content with their parents' current level of involvement, while 11% wish their parents were more involved in their academic careers.

  20. Radiological protection in North American naturally occurring radioactive material industries.

    PubMed

    Chambers, D B

    2015-06-01

    All soils and rocks contain naturally occurring radioactive material (NORM). Many ores and raw materials contain relatively high levels of natural radionuclides, and processing such materials can further increase the concentrations of natural radionuclides, sometimes referred to as 'technologically enhanced naturally occurring radioactive material' (TENORM). Examples of NORM minerals include uranium ores, monazite (a source of rare earth minerals), and phosphate rock used to produce phosphate fertiliser. Such activities have the potential to result in above background radiation exposure to workers and the public. The objective of this paper is to review the sources and exposure from NORM in North American industries, and provide a perspective on the potential radiological hazards to workers and the environment. Proper consideration of NORM issues is important and needs to be integrated in the assessment of these projects. Concerns over radioactivity and radiation amongst non-governmental organisations and the local public have resulted in the cancellation of NORM mining and mineral extraction projects, as well as inhibition of the safe use of by-product materials from various NORM industries. This paper also briefly comments on the current regulatory framework for NORM (TENORM) in Canada and the USA, as well as the potential implications of the recent activities of the International Commission on Radiological Protection for NORM industries. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  1. Increasing diversity in radiologic technology.

    PubMed

    Carwile, Laura

    2003-01-01

    Diversity is increasingly important in the radiologic technology workplace. For significant changes to occur in work force diversity, educators must first recruit and retain students from a wide variety of backgrounds. This article examines personality, race and gender as factors affecting career choice and how educators can use these factors to increase diversity in their programs. An overview of the ASRT's efforts to improve diversity within the profession is presented, along with suggestions for developing effective recruitment and retention plans to increase diversity.

  2. FORENSIC RADIOLOGY AND IMAGING FOR VETERINARY RADIOLOGISTS.

    PubMed

    Watson, Elizabeth; Heng, Hock Gan

    2017-05-01

    Imaging studies are often of evidentiary value in medicolegal investigations involving animals and the role of the veterinary radiologist is to interpret those images for courts as an expert or opinion witness. With progressing interest in prosecuting animal crimes and strengthening of penalties for crimes against animals, the participation of veterinary radiologists in medicolegal investigations is expected to increase. Veterinary radiologists who are aware of radiographic and imaging signs that result in animal suffering, abuse, or neglect; knowledgeable in ways radiology and imaging may support cause of death determinations; conversant in postmortem imaging; comfortable discussing mechanisms and timing of blunt or sharp force and projectile trauma in imaging; and prepared to identify mimics of abuse can assist court participants in understanding imaging evidence. The goal of this commentary review is to familiarize veterinary radiologists with the forensic radiology and imaging literature and with the advantages and disadvantages of various imaging modalities utilized in forensic investigations. Another goal is to provide background information for future research studies in veterinary forensic radiology and imaging. © 2017 American College of Veterinary Radiology.

  3. Attitudes of Radiologic Science Students, Technologists, and Clinical Instructors Regarding Their Experiential Learning and Career Capacity

    ERIC Educational Resources Information Center

    Burns, Caroline

    2012-01-01

    Radiologic science is an essential part of the healthcare continuum and preparing radiologic science students with experiential learning is essential. It is from this experience working with the patient that students begin to prepare for entry-level practice. The purpose of the study was to examine the attitudes of current radiologic science…

  4. Towards case-based medical learning in radiological decision making using content-based image retrieval

    PubMed Central

    2011-01-01

    Background Radiologists' training is based on intensive practice and can be improved with the use of diagnostic training systems. However, existing systems typically require laboriously prepared training cases and lack integration into the clinical environment with a proper learning scenario. Consequently, diagnostic training systems advancing decision-making skills are not well established in radiological education. Methods We investigated didactic concepts and appraised methods appropriate to the radiology domain, as follows: (i) Adult learning theories stress the importance of work-related practice gained in a team of problem-solvers; (ii) Case-based reasoning (CBR) parallels the human problem-solving process; (iii) Content-based image retrieval (CBIR) can be useful for computer-aided diagnosis (CAD). To overcome the known drawbacks of existing learning systems, we developed the concept of image-based case retrieval for radiological education (IBCR-RE). The IBCR-RE diagnostic training is embedded into a didactic framework based on the Seven Jump approach, which is well established in problem-based learning (PBL). In order to provide a learning environment that is as similar as possible to radiological practice, we have analysed the radiological workflow and environment. Results We mapped the IBCR-RE diagnostic training approach into the Image Retrieval in Medical Applications (IRMA) framework, resulting in the proposed concept of the IRMAdiag training application. IRMAdiag makes use of the modular structure of IRMA and comprises (i) the IRMA core, i.e., the IRMA CBIR engine; and (ii) the IRMAcon viewer. We propose embedding IRMAdiag into hospital information technology (IT) infrastructure using the standard protocols Digital Imaging and Communications in Medicine (DICOM) and Health Level Seven (HL7). Furthermore, we present a case description and a scheme of planned evaluations to comprehensively assess the system. Conclusions The IBCR-RE paradigm incorporates a novel combination of essential aspects of diagnostic learning in radiology: (i) Provision of work-relevant experiences in a training environment integrated into the radiologist's working context; (ii) Up-to-date training cases that do not require cumbersome preparation because they are provided by routinely generated electronic medical records; (iii) Support of the way adults learn while remaining suitable for the patient- and problem-oriented nature of medicine. Future work will address unanswered questions to complete the implementation of the IRMAdiag trainer. PMID:22032775

  5. Corporate social responsibility of future radiology professionals.

    PubMed

    Collins, Sandra K; Collins, Kevin S

    2011-01-01

    Plagued by difficult economic times, many radiology managers may find themselves faced with ethical dilemmas surrounding ongoing organizational pressures to maintain high levels of productivity with restricted resources. This often times tests the level of moral resilience and corporate social consciousness of even the most experienced radiology professionals. A study was conducted to determine what Corporate Social Responsibility (CSR) orientation and viewpoint future radiology professionals may have. The results of the study indicate that these study participants may initially consider patient care more important than profit maximization. Study results indicate that these specific future radiology professionals will not need laws, legal sanctions, and intensified rules to force them to act ethically. However,they may need ongoing training as to the necessity of profit maximization if they seek the highest quality of care possible for their patients.

  6. Evaluation of Stress and a Stress-Reduction Program Among Radiologic Technologists.

    PubMed

    Reingold, Lynn

    2015-01-01

    To investigate stress levels and causes of stress among radiologic technologists and determine whether an intervention could reduce stress in a selected radiologic technologist population. Demographic characteristics and data on preintervention stress sources and levels were collected through Internet-based questionnaires. A 6-week, self-administered, mindfulness-based stress-reduction program was conducted as a pilot intervention with 42 radiologic technologists from the Veterans Administration Medical Center. Data also were collected postintervention. Identified sources of stress were compared with findings from previous studies. Some radiologic technologists experienced improvement in their perceptions of stress after the intervention. Sources of stress for radiologic technologists were similar to those shown in earlier research, including inconsistent management, poor management communication, conflicting demands, long work hours, excessive workloads, lack of work breaks, and time pressures. The mindfulness-based stress-reduction program is an example of an inexpensive method that could improve personal well-being, reduce work errors, improve relationships in the workplace, and increase job satisfaction. More research is needed to determine the best type of intervention for stress reduction in a larger radiologic technologist population.

  7. Neurofilament light chain and oligoclonal bands are prognostic biomarkers in radiologically isolated syndrome.

    PubMed

    Matute-Blanch, Clara; Villar, Luisa M; Álvarez-Cermeño, José C; Rejdak, Konrad; Evdoshenko, Evgeniy; Makshakov, Gleb; Nazarov, Vladimir; Lapin, Sergey; Midaglia, Luciana; Vidal-Jordana, Angela; Drulovic, Jelena; García-Merino, Antonio; Sánchez-López, Antonio J; Havrdova, Eva; Saiz, Albert; Llufriu, Sara; Alvarez-Lafuente, Roberto; Schroeder, Ina; Zettl, Uwe K; Galimberti, Daniela; Ramió-Torrentà, Lluís; Robles, René; Quintana, Ester; Hegen, Harald; Deisenhammer, Florian; Río, Jordi; Tintoré, Mar; Sánchez, Alex; Montalban, Xavier; Comabella, Manuel

    2018-04-01

    The prognostic role of cerebrospinal fluid molecular biomarkers determined in early pathogenic stages of multiple sclerosis has yet to be defined. In the present study, we aimed to investigate the prognostic value of chitinase 3 like 1 (CHI3L1), neurofilament light chain, and oligoclonal bands for conversion to clinically isolated syndrome and to multiple sclerosis in 75 patients with radiologically isolated syndrome. Cerebrospinal fluid levels of CHI3L1 and neurofilament light chain were measured by enzyme-linked immunosorbent assay. Uni- and multivariable Cox regression models including as covariates age at diagnosis of radiologically isolated syndrome, number of brain lesions, sex and treatment were used to investigate associations between cerebrospinal fluid CHI3L1 and neurofilament light chain levels and time to conversion to clinically isolated syndrome and multiple sclerosis. Neurofilament light chain levels and oligoclonal bands were independent risk factors for the development of clinically isolated syndrome (hazard ratio = 1.02, P = 0.019, and hazard ratio = 14.7, P = 0.012, respectively) and multiple sclerosis (hazard ratio = 1.03, P = 0.003, and hazard ratio = 8.9, P = 0.046, respectively). The best cut-off to classify cerebrospinal fluid neurofilament light chain levels into high and low was 619 ng/l, and high neurofilament light chain levels were associated with a trend to shorter time to clinically isolated syndrome (P = 0.079) and significant shorter time to multiple sclerosis (P = 0.017). Similarly, patients with radiologically isolated syndrome presenting positive oligoclonal bands converted faster to clinically isolated syndrome and multiple sclerosis (P = 0.005 and P = 0.008, respectively). The effects of high neurofilament light chain levels shortening time to clinically isolated syndrome and multiple sclerosis were more pronounced in radiologically isolated syndrome patients with ≥37 years compared to younger patients. Cerebrospinal fluid CHI3L1 levels did not influence conversion to clinically isolated syndrome and multiple sclerosis in radiologically isolated syndrome patients. Overall, these findings suggest that cerebrospinal neurofilament light chain levels and oligoclonal bands are independent predictors of clinical conversion in patients with radiologically isolated syndrome. The association with a faster development of multiple sclerosis reinforces the importance of cerebrospinal fluid analysis in patients with radiologically isolated syndrome.

  8. Radiological air quality in a depleted uranium storage vault

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, T.; Cucchiara, A.L.

    1999-03-01

    The radiological air quality of two storage vaults, one with depleted uranium (DU) and one without, was evaluated and compared. The intent of the study was to determine if the presence of stored DU would significantly contribute to the gaseous/airborne radiation level compared to natural background. Both vaults are constructed out of concrete and are dimensionally similar. The vaults are located on the first floor of the same building. Neither vault has air supply or air exhaust. The doors to both vaults remained closed during the evaluation period, except for brief and infrequent access by the operational group. One vaultmore » contained 700 KG of depleted uranium, and the other vault contained documents inside of file cabinets. Radon detectors and giraffe air samplers were used to gather data on the quantity of gaseous/airborne radionuclides in both vaults. The results of this study indicated that there was no significant difference in the quantity of gaseous/airborne radionuclides in the two vaults. This paper gives a discussion of the effects of the stored DU on the air quality, and poses several theories supporting the results.« less

  9. Generalized image contrast enhancement technique based on the Heinemann contrast discrimination model

    NASA Astrophysics Data System (ADS)

    Liu, Hong; Nodine, Calvin F.

    1996-07-01

    This paper presents a generalized image contrast enhancement technique, which equalizes the perceived brightness distribution based on the Heinemann contrast discrimination model. It is based on the mathematically proven existence of a unique solution to a nonlinear equation, and is formulated with easily tunable parameters. The model uses a two-step log-log representation of luminance contrast between targets and surround in a luminous background setting. The algorithm consists of two nonlinear gray scale mapping functions that have seven parameters, two of which are adjustable Heinemann constants. Another parameter is the background gray level. The remaining four parameters are nonlinear functions of the gray-level distribution of the given image, and can be uniquely determined once the previous three are set. Tests have been carried out to demonstrate the effectiveness of the algorithm for increasing the overall contrast of radiology images. The traditional histogram equalization can be reinterpreted as an image enhancement technique based on the knowledge of human contrast perception. In fact, it is a special case of the proposed algorithm.

  10. Determining a pre-mining radiological baseline from historic airborne gamma surveys: a case study.

    PubMed

    Bollhöfer, Andreas; Beraldo, Annamarie; Pfitzner, Kirrilly; Esparon, Andrew; Doering, Che

    2014-01-15

    Knowing the baseline level of radioactivity in areas naturally enriched in radionuclides is important in the uranium mining context to assess radiation doses to humans and the environment both during and after mining. This information is particularly useful in rehabilitation planning and developing closure criteria for uranium mines as only radiation doses additional to the natural background are usually considered 'controllable' for radiation protection purposes. In this case study we have tested whether the method of contemporary groundtruthing of a historic airborne gamma survey could be used to determine the pre-mining radiological conditions at the Ranger mine in northern Australia. The airborne gamma survey was flown in 1976 before mining started and groundtruthed using ground gamma dose rate measurements made between 2007 and 2009 at an undisturbed area naturally enriched in uranium (Anomaly 2) located nearby the Ranger mine. Measurements of (226)Ra soil activity concentration and (222)Rn exhalation flux density at Anomaly 2 were made concurrent with the ground gamma dose rate measurements. Algorithms were developed to upscale the ground gamma data to the same spatial resolution as the historic airborne gamma survey data using a geographic information system, allowing comparison of the datasets. Linear correlation models were developed to estimate the pre-mining gamma dose rates, (226)Ra soil activity concentrations, and (222)Rn exhalation flux densities at selected areas in the greater Ranger region. The modelled levels agreed with measurements made at the Ranger Orebodies 1 and 3 before mining started, and at environmental sites in the region. The conclusion is that our approach can be used to determine baseline radiation levels, and provide a benchmark for rehabilitation of uranium mines or industrial sites where historical airborne gamma survey data are available and an undisturbed radiological analogue exists to groundtruth the data. © 2013.

  11. Radiological Technology. Secondary Curriculum Guide.

    ERIC Educational Resources Information Center

    Simpson, Bruce; And Others

    This curriculum guide was designed for use in postsecondary radiological technology education programs in Georgia. Its purpose is to provide for the development of entry level skills in radiological technology in the areas of knowledge, theoretical structure, tool usage, diagnostic ability, related supportive skills, and occupational survival…

  12. Should radiology residents be taught evidence-based radiology? An experiment with "the EBR Journal Club".

    PubMed

    Heilbrun, Marta E

    2009-12-01

    Introduce radiology residents to evidence-based radiology (EBR) using a journal club format based on the Radiology Alliance for Health Services Research/American Alliance of Academic Chief Residents in Radiology (RAHSR/A3CR2) Critical Thinking Skills sessions and EBR series of articles published in Radiology in 2007. The club began with a presentation outlining the process that would occur in an alternating format, with topics and articles chosen by residents. In session A, questions were rephrased in a Patient/Population, Intervention, Comparison, Outcome format, and a literature search was performed. Articles were discussed in session B, with residents assigned by year to the tasks of article summary, technology assessment, and comparison to checklists (Standards for Reporting of Diagnostic Accuracy, Consolidated Standards of Reporting Trials, or Quality of Reporting of Meta-analysis). The residents collectively assigned a level of evidence to each article, and a scribe provided a summary. Twenty-two residents participated, with 12/22 (55%) of residents submitting any question, 6/22 (27.3%) submitting more than one question, and 4 residents submitting questions in more than one session. Topics included radiation risk, emergency radiology, screening examinations, modality comparisons, and technology assessment. Of the 31 articles submitted for review, 15 were in radiology journals and 5 were published before 2000. For 2/9 topics searched, no single article that the residents selected was available through our library's subscription service. The maximum level of evidence assigned by residents was level III, "limited evidence." In each session, the residents concluded that they became less confident in the "right answer." They proposed that future reading recommendations come from attendings rather than literature searches. A journal club format is an effective tool to teach radiology residents EBR principles. Resistance comes from the difficulty in accessing good literature for review and in constructing good review questions.

  13. Socioeconomic status and the utilization of diagnostic imaging in an urban setting

    PubMed Central

    Demeter, Sandor; Reed, Martin; Lix, Lisa; MacWilliam, Leonard; Leslie, William D.

    2005-01-01

    Background In publicly funded health care systems, the utilization of health care services should be equitable, irrespective of socioeconomic status (SES). Although the association between SES and health care utilization has been examined in Canada relative to surgical, cardiac and preventive health care services, no published studies have specifically explored the association between SES and diagnostic imaging. Methods We examined over 300 000 diagnostic imaging claims made in the Winnipeg Regional Health Authority between Apr. 1, 2001, and Mar. 31, 2002. Using patient postal codes, we assigned SES on the basis of average household incomes in Canada's 1996 census. Using multiple regression, we examined the association between income quintile, patient age group (≤16, 17–64, ≥ 65 years), patient morbidity level according to the Johns Hopkins University Adjusted Clinical Group method (high, moderate, low), and imaging modality (general radiology, vascular, computed tomography, magnetic resonance, and general and obstetric ultrasound). Results Relative rates (RR) of diagnostic imaging utilization (highest v. lowest income quintile) were significantly increased in pediatric and adult patient groups at all morbidity levels receiving general radiology (highest RR 2.47, 95% confidence interval [CI] 2.07–2.93); pediatric and adult patient groups at high and low morbidity levels and elderly patient groups at low morbidity levels receiving general ultrasound (highest RR 2.26, 95% CI 1.20–4.26); pediatric and adult patient groups at all morbidity levels and elderly patients at high and moderate morbidity levels receiving magnetic resonance imaging (highest RR 2.51, 95% CI 1.78– 3.52); and adult patient groups at all morbidity levels receiving computed tomography (highest RR 1.46, 95% CI 1.35– 1.59). A lower RR of diagnostic imaging utilization in the highest income quintile was found only among patients receiving obstetric ultrasound (RR 0.80, 95% CI 0.73–0.87). No significant associations were found among elderly patients receiving general radiology or computed tomography or adult patients receiving vascular imaging. Interpretation We found a pattern of increased diagnostic imaging utilization in patient groups with a higher SES. Further research is needed to better understand the nature of this finding and how it contributes to health outcomes. PMID:16275968

  14. Waste Characterization Process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lambert, Patrick E.

    2014-11-01

    The purpose is to provide guidance to the Radiological Characterization Reviewer to complete the radiological characterization of waste items. This information is used for Department of Transportation (DOT) shipping and disposal, typically at the Nevada National Security Site (NNSS). Complete characterization ensures compliance with DOT shipping laws and NNSS Waste Acceptance Criteria (WAC). The fines for noncompliance can be extreme. This does not include possible bad press, and endangerment to the public, employees and the environment. A Radiological Characterization Reviewer has an important role in the organization. The scope is to outline the characterization process, but does not to includemore » every possible situation. The Radiological Characterization Reviewer position requires a strong background in Health Physics; therefore, these concepts are minimally addressed. The characterization process includes many Excel spreadsheets that were developed by Michael Enghauser known as the WCT software suite. New Excel spreadsheets developed as part of this project include the Ra- 226 Decider and the Density Calculator by Jesse Bland, MicroShield Density Calculator and Molecular Weight Calculator by Pat Lambert.« less

  15. IRQN award paper: Operational rounds: a practical administrative process to improve safety and clinical services in radiology.

    PubMed

    Donnelly, Lane F; Dickerson, Julie M; Lehkamp, Todd W; Gessner, Kevin E; Moskovitz, Jay; Hutchinson, Sally

    2008-11-01

    As part of a patient safety program in the authors' department of radiology, operational rounds have been instituted. This process consists of radiology leaders' visiting imaging divisions at the site of imaging and discussing frontline employees' concerns about patient safety, the quality of care, and patient and family satisfaction. Operational rounds are executed at a time to optimize the number of attendees. Minutes that describe the issues identified, persons responsible for improvement, and updated improvement plan status are available to employees online. Via this process, multiple patient safety and other issues have been identified and remedied. The authors believe that the process has improved patient safety, the quality of care, and the efficiency of operations. Since the inception of the safety program, the mean number of days between serious safety events involving radiology has doubled. The authors review the background around such walk rounds, describe their particular program, and give multiple illustrative examples of issues identified and improvement plans put in place.

  16. A new approach to the treatment of nasal bone fracture: radiologic classification of nasal bone fractures and its clinical application.

    PubMed

    Han, Daniel Seung Youl; Han, Yea Sik; Park, Jin Hyung

    2011-11-01

    A radiologic examination is required in the treatment of nasal bone fracture to determine the fracture condition. Thus, there is an increasing need for radiologic classification of nasal bone fractures that can be applied to clinical practice. Computed tomography was performed in 125 patients with nasal bone fractures to determine which axial view best showed the entire nasal view. The obtained axial view was then used as a reference for classification. The length from the top to the base of the nasal bone was divided into upper, middle, and lower levels, after which the fracture location was determined. If the fracture spanned the boundaries of these levels, it was classified as the total level. Subsequently, the fracture was subclassified based on the fracture direction and pattern and the concurrent fracture. Radiologic examination of patients with nasal bone fracture showed that nasal bone fracture was frequently found at the total, middle, upper, and lower levels, in that order. Nasal bone fractures at the upper level showed lower frequencies of complication and reoperation than the fractures at the other levels, whereas nasal bone fractures at the total level showed the highest frequencies of complication and reoperation. Radiologic classification can be useful for preoperative and postoperative evaluations of nasal bone fractures and can be helpful in understanding such fractures because it can efficiently predict the prognosis of a fracture. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. ACR-SNM Task Force on Nuclear Medicine Training: report of the task force.

    PubMed

    Guiberteau, Milton J; Graham, Michael M

    2011-06-01

    The expansion of knowledge and technological advances in nuclear medicine and radiology require physicians to have more expertise in functional and anatomic imaging. The convergence of these two specialties into the new discipline of molecular imaging has also begun to place demands on residency training programs for additional instruction in physiology and molecular biology. These changes have unmasked weaknesses in current nuclear medicine and radiology training programs. Adding to the impetus for change are the attendant realities of the job market and uncertain employment prospects for physicians trained in nuclear medicine but not also trained in diagnostic radiology. With this background, the ACR and the Society of Nuclear Medicine convened the Task Force on Nuclear Medicine Training to define the issues and develop recommendations for resident training.

  18. Bulgarian experience in the establishment of reference dose levels and implementation of a quality control system in diagnostic radiology.

    PubMed

    Vassileva, J; Dimov, A; Slavchev, A; Karadjov, A

    2005-01-01

    Results from a Bulgarian patient dose survey in diagnostic radiology are presented. Reference levels for entrance surface dose (ESD) were 0.9 mGy for chest radiography (PA), 30 mGy for lumbar spine (Lat), 10 mGy for pelvis, 5 mGy for skull (AP), 3 mGy for skull (Lat) and 13 mGy for mammography. Quality control (QC) programmes were proposed for various areas of diagnostic radiology. Film processing QC warranted special attention. Proposed QC programmes included parameters to be tested, level of expertise needed and two action levels: remedial and suspension. Programmes were tested under clinical conditions to assess initial results and draw conclusions for further QC system development. On the basis of international experience, measurement protocols were developed for all parameters tested. QC equipment was provided as part of the PHARE project. A future problem for QC programme implementation may be the small number of medical physics experts in diagnostic radiology.

  19. ICRP Publication 132: Radiological Protection from Cosmic Radiation in Aviation.

    PubMed

    Lochard, J; Bartlett, D T; Rühm, W; Yasuda, H; Bottollier-Depois, J-F

    2016-06-01

    In this publication, the International Commission on Radiological Protection (ICRP) provides updated guidance on radiological protection from cosmic radiation in aviation, taking into account the current ICRP system of radiological protection, the latest available data on exposures in aviation, and experience gained worldwide in the management of exposures in aviation. The publication describes the origins of cosmic radiation, how it exposes passengers and aircraft crew, the basic radiological protection principles that apply to this existing exposure situation, and the available protective actions. For implementation of the optimisation principle, the Commission recommends a graded approach proportionate to the level of exposure that may be received by individuals. The objective is to keep the exposure of the most exposed individuals to a reasonable level. The Commission also recommends that information be disseminated to raise awareness about cosmic radiation, and to support informed decisions among concerned stakeholders.

  20. Radioactive Waste Management Complex low-level waste radiological performance assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maheras, S.J.; Rood, A.S.; Magnuson, S.O.

    This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsitemore » receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected.« less

  1. Assessment of radiological protection systems among diagnostic radiology facilities in North East India.

    PubMed

    Singh, Thokchom Dewan; Jayaraman, T; Arunkumar Sharma, B

    2017-03-01

    This study aims to assess the adequacy level of radiological protection systems available in the diagnostic radiology facilities located in three capital cities of North East (NE) India. It further attempts to understand, using a multi-disciplinary approach, how the safety codes/standards in diagnostic radiology framed by the Atomic Energy Regulatory Board (AERB) and the International Atomic Energy Agency (IAEA) to achieve adequate radiological protection in facilities, have been perceived, conceptualized, and applied accordingly in these facilities. About 30 diagnostic radiology facilities were randomly selected from three capitals of states in NE India; namely Imphal (Manipur), Shillong (Meghalaya) and Guwahati (Assam). A semi-structured questionnaire developed based on a multi-disciplinary approach was used for this study. It was observed that radiological practices undertaken in these facilities were not exactly in line with safety codes/standards in diagnostic radiology of the AERB and the IAEA. About 50% of the facilities had registered/licensed x-ray equipment with the AERB. More than 80% of the workers did not use radiation protective devices, although these devices were available in the facilities. About 85% of facilities had no institutional risk management system. About 70% of the facilities did not carry out periodic quality assurance testing of their x-ray equipment or surveys of radiation leakage around the x-ray room, and did not display radiation safety indicators in the x-ray rooms. Workers in these facilities exhibited low risk perception about the risks associated with these practices. The majority of diagnostic radiology facilities in NE India did not comply with the radiological safety codes/standards framed by the AERB and IAEA. The study found inadequate levels of radiological protection systems in the majority of facilities. This study suggests a need to establish firm measures that comply with the radiological safety codes/standards of the AERB and IAEA to protect patients, workers and the public of this region.

  2. What causes increasing and unnecessary use of radiological investigations? a survey of radiologists' perceptions

    PubMed Central

    Lysdahl, Kristin B; Hofmann, Bjørn M

    2009-01-01

    Background Growth in use and overuse of diagnostic imaging significantly impacts the quality and costs of health care services. What are the modifiable factors for increasing and unnecessary use of radiological services? Various factors have been indentified, but little is known about their relative impact. Radiologists hold key positions for providing such knowledge. Therefore the purpose of this study was to obtain radiologists' perspective on the causes of increasing and unnecessary use of radiological investigations. Methods In a mailed questionnaire radiologist members of the Norwegian Medical Association were asked to rate potential causes of increased investigation volume (fifteen items) and unnecessary investigations (six items), using five-point-scales. Responses were analysed by using summary statistics and Factor Analysis. Associations between variables were determined using Students' t-test, Spearman rank correlation and Chi-Square tests. Results The response rate was 70% (374/537). The highest rated causes of increasing use of radiological investigations were: a) new radiological technology, b) peoples' demands, c) clinicians' intolerance for uncertainty, d) expanded clinical indications, and e) availability. 'Over-investigation' and 'insufficient referral information' were reported the most frequent causes of unnecessary investigations. Correlations between causes of increasing and unnecessary radiology use were identified. Conclusion In order to manage the growth in radiological imaging and curtail inappropriate investigations, the study findings point to measures that influence the supply and demand of services, specifically to support the decision-making process of physicians. PMID:19723302

  3. Characteristics and quality of published animal research in the field of radiology.

    PubMed

    Yoon, Soo Jeong; Yoon, Dae Young; Cho, Young Kwon; Baek, Sora; Lim, Kyoung Ja; Seo, Young Lan; Yun, Eun Joo

    2017-06-01

    Background Animal research has played an important role in the field of radiology. Purpose To evaluate the characteristics and quality of published radiological animal research. Material and Methods A PubMed search was performed for radiological animal research articles (defined as studies using animal models with a radiologist as the first author) published in 1994, 2004, and 2014. The following information was extracted from each article: journal name, radiological subspecialty, imaging technique, animal species, number of animals used, number of authors, declared funding, country of origin, methodological quality, and ethical quality. Methodological and ethical quality of studies were assessed with seven-item (sample size calculation, animal age, animal sex, animal weight, inclusion and exclusion criteria, randomization, and blinded outcome assessment) and four-item (ethical review committee approval, anesthesia, pain control, and euthanasia) scales, respectively. Results The numbers of radiological animal studies markedly increased, from 91 in 1994 to 163 in 2004 and to 305 in 2014. One hundred and sixty-two (29.0%) articles focused on the neuroradiology/head and neck subspecialty, 233 (41.7%) used magnetic resonance imaging (MRI), 190 (34.0%) used mice, 254 (45.4%) used 10-30 animals, 297 (53.1%) had 4-7 authors, 392 (70.1%) were funded, and 222 (39.7%) were from the USA. Six of 7 methodological and 3/4 ethical quality items significantly improved over time. Conclusion The quantity and quality of radiological animal research has increased over the last two decades; however, methodological and ethical quality remains suboptimal.

  4. Radiological examinations of the anatomy of the inferior turbinate using digital volume tomography (DVT).

    PubMed

    Balbach, L; Trinkel, V; Guldner, C; Bien, S; Teymoortash, A; Werner, J A; Bremke, M

    2011-06-01

    Since the last 120 years there were only few descriptions of the anatomical sizes of the inferior turbinate in the literature. On this background the current study should evaluate the radiological dimensions of the inferior turbinate and the septum using DVT. The latest generation of the Accu-I-tomo was used. The data of 100 adult patients have been evaluated. The bony length was found to be 38.9 mm, the mucosal length 51.0 mm. The findings of the total mucosal thickness at different measuring points were between 8.1 mm and 10.9 mm, those of the bony thickness were between 0.9 mm and 2.3 mm and those of the bony height were between 3.9 mm and 20.8 mm. The results of this radiological study are able to point out the importance of preoperative anatomical evaluation of radiological images. The preoperative focus on the individual anatomy is very important because of the choice of an adequate surgical treatment. Today new radiological techniques can help to find out whether the reason for hypertrophied turbinates is caused by bone, mucosa or both. This knowledge enables a concerted treatment concept.

  5. Health literacy in vascular and interventional radiology: a comparative analysis of online patient education resources.

    PubMed

    Hansberry, David R; Kraus, Carl; Agarwal, Nitin; Baker, Stephen R; Gonzales, Sharon F

    2014-08-01

    The Internet is frequently accessed by patients as a resource for medical knowledge. However, the provided material is typically written at a level well above the recommended 7th grade level. A clear understanding of the capabilities, limitations, risks, and benefits of interventional radiology by patients, both current and prospective, is hindered when the textual information offered to the public is pitched at a level of sophistication too high for general comprehension. In January 2013, all 25 patient education resources from the Cardiovascular and Interventional Radiology Society of Europe (CIRSE) Web site ( http://www.cirse.org ) and all 31 resources from the Society of Interventional Radiology (SIR) Web site ( http://www.sirweb.org ) were analyzed for their specific level of readability using ten quantitative scales: Flesch Reading Ease, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook, Gunning fog index, New Fog Count, Coleman-Liau index, FORCAST formula, Fry graph, Raygor Readability Estimate, and New Dale-Chall. Collectively, the patient education resources on the CIRSE Web site are written at the 12.3 grade level, while the resources on the SIR Web site are written at the 14.5 grade level. Educational health care materials available on both the CIRSE and the SIR Web sites are presented in language in the aggregate that could be too difficult for many lay people to fully understand. Given the complex nature of vascular and interventional radiology, it may be advantageous to rewrite these educational resources at a lower reading level to increase comprehension.

  6. The mandate and work of ICRP Committee 3 on radiological protection in medicine.

    PubMed

    Miller, D L; Martin, C J; Rehani, M M

    2018-01-01

    The mandate of Committee 3 of the International Commission on Radiological Protection (ICRP) is concerned with the protection of persons and unborn children when ionising radiation is used in medical diagnosis, therapy, and biomedical research. Protection in veterinary medicine has been newly added to the mandate. Committee 3 develops recommendations and guidance in these areas. The most recent documents published by ICRP that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (ICRP Publication 129) and 'Radiological protection in ion beam radiotherapy' (ICRP Publication 127). A report in cooperation with ICRP Committee 2 entitled 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (ICRP Publication 128) has also been published. 'Diagnostic reference levels in medical imaging' (ICRP Publication 135), published in 2017, provides specific advice on the setting and use of diagnostic reference levels for diagnostic and interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and multi-modality procedures. 'Occupational radiological protection in interventional procedures' was published in March 2018 as ICRP Publication 139. A document on radiological protection in therapy with radiopharmaceuticals is likely to be published in 2018. Work is in progress on several other topics, including appropriate use of effective dose in collaboration with the other ICRP committees, guidance for occupational radiological protection in brachytherapy, justification in medical imaging, and radiation doses to patients from radiopharmaceuticals (an update to ICRP Publication 128). Committee 3 is also considering the development of guidance on radiological protection in medicine related to individual radiosusceptibility, in collaboration with ICRP Committee 1.

  7. Magnetic Resonance Imaging Interpretation in Patients With Symptomatic Lumbar Spine Disc Herniations

    PubMed Central

    Lurie, Jon D.; Doman, David M.; Spratt, Kevin F.; Tosteson, Anna N. A.; Weinstein, James N.

    2009-01-01

    Study Design Retrospective review of imaging data from a clinical trial. Objective To compare the interpretation of lumbar spine magnetic resonance imaging (MRIs) by clinical spine specialists and radiologists in patients with lumbar disc herniation. Summary of Background Data MRI is the imaging modality of choice for evaluation of the lumbar spine in patients with suspected lumbar disc herniation. Guidelines provide standardization of terms to more consistently describe disc herniation. The extent to which these guidelines are being followed in clinical practice is unknown. Methods We abstracted data from radiology reports from patients with lumbar intervertebral disc herniation enrolled in the Spine Patient Outcomes Research Trial. We evaluated the frequency with which morphology (e.g., protrusions, extrusions, or sequestrations) was reported as per guidelines and when present we compared the morphology ratings to those of clinicians who completed a structured data form as part of the trial. We assessed agreement using percent agreement and the κ statistic. Results There were 396 patients with sufficient data to analyze. Excellent agreement was observed between clinician and radiologist on the presence and level of herniation (93.4%), with 3.3% showing disagreement regarding level, of which a third could be explained by the presence of a transitional vertebra. In 3.3% of the cases in which the clinician reported a herniation (protrusion, extrusion, or sequestration), the radiologist reported no herniation on the MRI. The radiology reports did not clearly describe morphology in 42.2% of cases. In the 214 cases with clear morphologic descriptions, agreement was fair (κ = 0.24) and the disagreement was asymmetric (Bowker’s test of symmetry P < 0.0001) with clinicians more often rating more abnormal morphologic categories. Agreement on axial location of the herniation was excellent (κ = 0.81). There was disagreement between left or right side in only 3.3% of cases (κ = 0.93). Conclusion Radiology reports frequently fail to provide sufficient detail to describe disc herniation morphology. Agreement between MRI readings by clinical spine specialists and radiologists was excellent when comparing herniation vertebral level and location within level, but only fair comparing herniation morphology. PMID:19333103

  8. GRDC. A Collaborative Framework for Radiological Background and Contextual Data Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brian J. Quiter; Ramakrishnan, Lavanya; Mark S. Bandstra

    The Radiation Mobile Analysis Platform (RadMAP) is unique in its capability to collect both high quality radiological data from both gamma-ray detectors and fast neutron detectors and a broad array of contextual data that includes positioning and stance data, high-resolution 3D radiological data from weather sensors, LiDAR, and visual and hyperspectral cameras. The datasets obtained from RadMAP are both voluminous and complex and require analyses from highly diverse communities within both the national laboratory and academic communities. Maintaining a high level of transparency will enable analysis products to further enrich the RadMAP dataset. It is in this spirit of openmore » and collaborative data that the RadMAP team proposed to collect, calibrate, and make available online data from the RadMAP system. The Berkeley Data Cloud (BDC) is a cloud-based data management framework that enables web-based data browsing visualization, and connects curated datasets to custom workflows such that analysis products can be managed and disseminated while maintaining user access rights. BDC enables cloud-based analyses of large datasets in a manner that simulates real-time data collection, such that BDC can be used to test algorithm performance on real and source-injected datasets. Using the BDC framework, a subset of the RadMAP datasets have been disseminated via the Gamma Ray Data Cloud (GRDC) that is hosted through the National Energy Research Science Computing (NERSC) Center, enabling data access to over 40 users at 10 institutions.« less

  9. Analysis of the criteria used by the International Commission on Radiological Protection to justify the setting of numerical protection level values.

    PubMed

    2006-01-01

    This report compiles the various numerical protection level values published by the International Commission on Radiological Protection (ICRP) since its 1990 Recommendations (Publication 60). Several terms are used to denominate the protection levels: individual dose limit, 'maximum' individual dose, dose constraint, exemption level, exclusion level, action level, or intervention level. The reasons provided by the Commission for selecting the associated numerical values is quoted as far as available. In some cases the rationale is not totally explicit in the original ICRP report concerned; in such cases the Task Group that prepared the present report have proposed their own interpretation. Originally, this report was prepared by a Task Group at CEPN, a French research and development center, in behalf of IRSN, a French public expert body engaged in radiological protection and nuclear safety. It is published here with kind permission by CEPN and IRSN.

  10. Reference Levels for Patient Radiation Doses in Interventional Radiology: Proposed Initial Values for U.S. Practice1

    PubMed Central

    Miller, Donald L.; Kwon, Deukwoo; Bonavia, Grant H.

    2009-01-01

    Purpose: To propose initial values for patient reference levels for fluoroscopically guided procedures in the United States. Materials and Methods: This secondary analysis of data from the Radiation Doses in Interventional Radiology Procedures (RAD-IR) study was conducted under a protocol approved by the institutional review board and was HIPAA compliant. Dose distributions (percentiles) were calculated for each type of procedure in the RAD-IR study where there were data from at least 30 cases. Confidence intervals for the dose distributions were determined by using bootstrap resampling. Weight banding and size correction methods for normalizing dose to patient body habitus were tested. Results: The different methods for normalizing patient radiation dose according to patient weight gave results that were not significantly different (P > .05). The 75th percentile patient radiation doses normalized with weight banding were not significantly different from those that were uncorrected for body habitus. Proposed initial reference levels for various interventional procedures are provided for reference air kerma, kerma-area product, fluoroscopy time, and number of images. Conclusion: Sufficient data exist to permit an initial proposal of values for reference levels for interventional radiologic procedures in the United States. For ease of use, reference levels without correction for body habitus are recommended. A national registry of radiation-dose data for interventional radiologic procedures is a necessary next step to refine these reference levels. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533090354/-/DC1 PMID:19789226

  11. Combination of radiological and gray level co-occurrence matrix textural features used to distinguish solitary pulmonary nodules by computed tomography.

    PubMed

    Wu, Haifeng; Sun, Tao; Wang, Jingjing; Li, Xia; Wang, Wei; Huo, Da; Lv, Pingxin; He, Wen; Wang, Keyang; Guo, Xiuhua

    2013-08-01

    The objective of this study was to investigate the method of the combination of radiological and textural features for the differentiation of malignant from benign solitary pulmonary nodules by computed tomography. Features including 13 gray level co-occurrence matrix textural features and 12 radiological features were extracted from 2,117 CT slices, which came from 202 (116 malignant and 86 benign) patients. Lasso-type regularization to a nonlinear regression model was applied to select predictive features and a BP artificial neural network was used to build the diagnostic model. Eight radiological and two textural features were obtained after the Lasso-type regularization procedure. Twelve radiological features alone could reach an area under the ROC curve (AUC) of 0.84 in differentiating between malignant and benign lesions. The 10 selected characters improved the AUC to 0.91. The evaluation results showed that the method of selecting radiological and textural features appears to yield more effective in the distinction of malignant from benign solitary pulmonary nodules by computed tomography.

  12. Environmental radiology assessment in Lahad Datu, Sabah

    NASA Astrophysics Data System (ADS)

    Siti Fharhana, Yusof; Wan Muhamad Saridan, Wan Hassan; Ahmad Termizi, Ramli; Mohd Hilmi, Sahini; Mohammad Syazwan, Mohd Sanusi; Nor Afifah, Basri; Nor Zati Hani, Abu Hanifah

    2017-10-01

    Monitoring terrestial gamma radiation is crucial to prepare a baseline data for environmental radiological protection. Radiological research was carried out in Lahad Datu, Sabah to obtain the radioactivity status and terrestrial gamma radiation level in the area. We measure the terrestrial gamma radiation dose rates and analyse the radioactivity concentration of primordial radionuclides for radiological risk assessment. We identified that the annual estimation of dose effective for public is below the public dose limit, 1 mSv per year. Public and environment safety and health are remain secure. The obtained data and results can be used as reference for environmental radiology protection.

  13. 78 FR 56775 - Waste Confidence-Continued Storage of Spent Nuclear Fuel

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-13

    ... radiological impacts of spent nuclear fuel and high-level waste disposal. DATES: Submit comments on the... determination. The ``Offsite radiological impacts of spent nuclear fuel and high-level waste disposal'' issue.... Geologic Repository--Technical Feasibility and Availability C3. Storage of Spent Nuclear Fuel C3.a...

  14. Fast neutron background characterization with the Radiological Multi-sensor Analysis Platform (RadMAP)

    DOE PAGES

    Davis, John R.; Brubaker, Erik; Vetter, Kai

    2017-03-29

    In an effort to characterize the fast neutron radiation background, 16 EJ-309 liquid scintillator cells were installed in the Radiological Multi-sensor Analysis Platform (RadMAP) to collect data in the San Francisco Bay Area. Each fast neutron event was associated with specific weather metrics (pressure, temperature, absolute humidity) and GPS coordinates. Furthermore, the expected exponential dependence of the fast neutron count rate on atmospheric pressure was demonstrated and event rates were subsequently adjusted given the measured pressure at the time of detection. Pressure adjusted data was also used to investigate the influence of other environmental conditions on the neutron background rate.more » Using National Oceanic and Atmospheric Administration (NOAA) coastal area lidar data, an algorithm was implemented to approximate sky-view factors (the total fraction of visible sky) for points along RadMAPs route. In the three areas we analyzed, San Francisco, Downtown Oakland, and Berkeley, all demonstrated a suppression in the background rate of over 50% for the range of sky-view factors measured. This effect, which is due to the shielding of cosmic-ray produced neutrons by surrounding buildings, was comparable to the pressure influence which yielded a 32% suppression in the count rate over the range of pressures measured.« less

  15. Ion Mobility Spectrometer Field Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Nicholas; McLain, Derek; Steeb, Jennifer

    The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levelsmore » of the radioanalytical instrumentation and determined to be radiologically clean.« less

  16. Academic Radiology in the New Healthcare Delivery Environment

    PubMed Central

    Qayyum, Aliya; Yu, John-Paul J.; Kansagra, Akash P.; von Fischer, Nathaniel; Costa, Daniel; Heller, Matthew; Kantartzis, Stamatis; Plowman, R. Scooter; Itri, Jason

    2014-01-01

    Ongoing concerns over the rising cost of health care are driving large-scale changes in the way that health care is practiced and reimbursed in the United States. To effectively implement and thrive within this new health care delivery environment, academic medical institutions will need to modify financial and business models and adapt institutional cultures. In this paper, we review the expected features of the new health care environment from the perspective of academic radiology departments. Our review will include background on Accountable Care Organizations, identify challenges associated with the new managed care model, and outline key strategies—including expanding the use of existing information technology infrastructure, promoting continued medical innovation, balancing academic research with clinical care, and exploring new roles for radiologists in efficient patient management—that will ensure continued success for academic radiology. PMID:24200477

  17. [Ergonomics of the workplace in radiology].

    PubMed

    García-Lallana, A; Viteri-Ramírez, G; Saiz-Mendiguren, R; Broncano, J; Dámaso Aquerreta, J

    2011-01-01

    The replacement of conventional films and view boxes with digital images and computer monitors managed by PACS has clearly improved the diagnostic imaging workplace. The new setup has many advantages, including increased productivity brought about by decreased overall time required for image interpretation. On the other hand, the implementation of the digital workplace has increased the importance of factors like background lighting and the position of the chair, work table, mouse, keyboard, and monitor to prevent lesions that can disable the radiologist. The influence of these factors is often undervalued in the design and implementation of the radiological workplace. This article provides recommendations for the design of the radiological workplace based on ergonomics, which is the science that studies interactions among humans and other elements of a system. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  18. Does gender impact upon application rejection rate among Canadian radiology residency applicants?

    PubMed

    Baerlocher, Mark O; Walker, Michelle

    2005-10-01

    To determine if and how gender ratios have changed within Canadian radiology, and to determine if gender discrimination occurs at the level of the radiology resident selection committee. The Canadian Medical Association, Canadian Association of Radiologists, Canadian Institute for Health Information, Royal College of Physicians and Surgeons of Canada, and Canadian Residency Matching Service provided gender-specific data. We compared the proportion of female applicants who ranked a radiology program as their top choice and were rejected from any radiology program with the corresponding proportion for male applicants. The numbers of women and men being awarded an MD from a Canadian university equalized nearly a decade ago. Women continue to be numerically underrepresented among practicing radiologists; however, the proportion of women continues to increase so that there is 1 female radiologist in practice to every 3 male radiologists in practice in 2005. More male medical students ranked a radiology residency training program as their top choice in the residency match; however, of those who did, they were as likely as women to be rejected from a radiology residency training program. Grouping all female and male graduating medical students participating in the residency match and ranking a radiology residency as their top choice between 1993 and 2004, the odds of men being rejected were 1.4 times (95% CI 0.99-1.9, p = 0.07) greater than for women. There continues to be more men than women radiologists in practice; however, the female-to-male ratio continues to increase. Our data suggest that discrimination against female applicants at the level of radiology residency selection does not occur.

  19. Source detection at 100 meter standoff with a time-encoded imaging system

    NASA Astrophysics Data System (ADS)

    Brennan, J.; Brubaker, E.; Gerling, M.; Marleau, P.; Monterial, M.; Nowack, A.; Schuster, P.; Sturm, B.; Sweany, M.

    2018-01-01

    We present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ∼ 1mCi252Cf radiological source at 100m standoff with 90% detection efficiency and 10% false positives against background in 12min. This same detection efficiency is met at 15s for a 40m standoff, and 1 . 2s for a 20m standoff.

  20. Annual radiological environmental operating report, Browns Ferry Nuclear Plant, 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-04-01

    This report describes the environmental radiological monitoring programs conducted by TVA in the vicinity of Browns Ferry Nuclear Plant in 1987. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels.more » Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstreams from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public. 3 refs., 2 figs., 34 tabs.« less

  1. Browns Ferry Nuclear Plant annual radiological environmental operating report, 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-04-01

    This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant in 1990. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels.more » Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstream from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public. 4 refs., 2 figs., 2 tabs.« less

  2. Annual radiological environmental operating report, Browns Ferry Nuclear Plant, 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-04-01

    This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant (BFN) in 1989. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiationmore » levels. Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts if plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstream from the plant. This activity in river sediment would result in no measurable increase over background in the dose to the general public. 4 refs., 2 figs., 2 tabs.« less

  3. Annual radiological environmental operating report, Browns Ferry Nuclear Plant, 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1989-04-01

    This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant in 1988. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels.more » Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstream from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public. 3 refs., 2 figs., 2 tabs.« less

  4. Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the PNNL Richland Campus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snyder, Sandra F.; Moleta, Donna Grace L.; Meier, Kirsten M.

    This is the second revision of the DQO Supporting Radiological Air Emissions Monitoring for the Pacific Northwest National Laboratory Richland Campus. In January 2017, the PNNL Richland Campus expanded to the north by 0.35 km 2 (85.6 acres). Under the requirements of Washington State Department of Health Radioactive Air Emissions License (RAEL)-005, the PNNL Campus operates and maintains a radiological air monitoring program. This revision documents and evaluates the newly acquired acreage while also removing recreational land at the southwest, and also re-examines all active radioactive emission units on the PNNL Campus. No buildings are located on this new Campusmore » land, which was transferred from the U.S. DOE Hanford Site. Additionally, this revision includes information regarding the background monitoring station PNL-5 in Benton City, Washington, which became active in October 2016. The key purpose of this revision is to determine the adequacy of the existing environmental surveillance stations to monitor radiological air emissions in light of this northern boundary change.« less

  5. Evaluation of awareness on radiation protection and knowledge about radiological examinations in healthcare professionals who use ionized radiation at work.

    PubMed

    Yurt, Ayşegül; Cavuşoğlu, Berrin; Günay, Türkan

    2014-06-01

    In this study, we evaluated the knowledge and perception and mitigation of hazards involved in radiological examinations, focusing on healthcare personnel who are not in radiation-related occupations, but who use ionising radiation as a part of their work. A questionnaire was applied to physicians, nurses, technicians and other staff working in different clinics that use radiation in their work, in order to evaluate their knowledge levels about ionizing radiation and their awareness about radiation doses resulting from radiological examinations. The statistical comparisons between the groups were analyzed with the Kruskal Wallis test using the SPSS program. Ninety two participants took part in the study. Their level of knowledge about ionizing radiation and doses in radiological examinations were found to be very weak. The number of correct answers of physicians, nurses, medical technicians and other personnel groups were 15.7±3.7, 13.0±4.0, 10.1±2.9 and 11.8±4.0, respectively. In the statistical comparison between the groups, the level of knowledge of physicians was found to be significantly higher than the level of the other groups (p=0.005). The present study demonstrated that general knowledge in relation to radiation, radiation protection, health risks and doses used for radiological applications are insufficient among health professions using with ionizing radiation in their work.

  6. Adult learning principles for effective teaching in radiology programmes: a review of the literature.

    PubMed

    Arogundade, R A

    2011-01-01

    Adult learning processes of acquisition of new knowledge, behaviours, skills, values or preferences generally occur as part of personal professional development. There is need for radiology residency trainers to understand the basic adult learning principles for effective teaching processes. To review the different adult learning styles, learning theories and educational practice as a guide for radiology residency trainers. Literature materials from journals, web articles and reputable textbooks in the last 20 years on adult learning principles in general and radiology in particular were reviewed. Most medical educators, including radiologists, lack appropriate formal training background in educational practice. The adult residency trainee brings to the learning environment high quantity and quality of experiences and some amount of control. Connection of this rich adult experience base to the learning process requires facilitation and motivation by the radiology educator, who must be familiar with the use of appropriate learning theories and educational practices. there is a general agreement about the content of good practice in adult education but a definite comprehensive list does not seem to exist in the literature. Nonetheless, understanding of the basic adult learning principles would aid the concept of guided training, where the adult residency trainee shoulders the bulk of the training responsibilities of acquisition of knowledge.

  7. Radiology Online Patient Education Materials Provided by Major University Hospitals: Do They Conform to NIH and AMA Guidelines?

    PubMed

    Prabhu, Arpan V; Donovan, Ashley L; Crihalmeanu, Tudor; Hansberry, David R; Agarwal, Nitin; Beriwal, Sushil; Kale, Hrishikesh; Heller, Matthew

    The internet creates opportunities for Americans to access medical information about imaging tests and modalities to guide them in their medical decision-making. Owing to health literacy variations in the general population, the American Medical Association and National Institutes of Health recommend patient education resources to be written between the third and seventh grade levels. Our purpose is to quantitatively assess the readability levels of online radiology educational materials, written for the public, in 20 major university hospitals. In September and October 2016, we identified 20 major university hospitals with radiology residency-affiliated hospital systems. On each hospital׳s website, we downloaded all radiology-related articles written for patient use. A total of 375 articles were analyzed for readability level using 9 quantitative readability scales that are well validated in the medical literature. The 375 articles from 20 hospital systems were collectively written at an 11.4 ± 3.0 grade level (range: 8.4-17.1). Only 11 (2.9%) articles were written at the recommended third to seventh grade levels. Overall, 126 (33.6%) were written above a full high-school reading level. University of Washington Medical Center׳s articles were the most readable with a reading level corresponding to 7.9 ± 0.9. The vast majority of websites at major academic hospitals with radiology residencies designed to provide patients with information about imaging were written above the nationally recommended health literacy guidelines to meet the needs of the average American. This may limit the benefit that patients can derive from these educational materials. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Inter-observer variability in diagnosing radiological features of aneurysmal subarachnoid hemorrhage; a preliminary single centre study comparing observers from different specialties and levels of training.

    PubMed

    Siddiqui, Usman T; Khan, Anjum F; Shamim, Muhammad Shahzad; Hamid, Rana Shoaib; Alam, Muhammad Mehboob; Emaduddin, Muhammad

    2014-01-01

    A noncontrast computed tomography (CT) scan remains the initial radiological investigation of choice for a patient with suspected aneurysmal subarachnoid hemorrhage (aSAH). This initial scan may be used to derive key information about the underlying aneurysm which may aid in further management. The interpretation, however, is subject to the skill and experience of the interpreting individual. The authors here evaluate the interpretation of such CT scans by different individuals at different levels of training, and in two different specialties (Radiology and Neurosurgery). Initial nonontrast CT scan of 35 patients with aSAH was evaluated independently by four different observers. The observers selected for the study included two from Radiology and two from Neurosurgery at different levels of training; a resident currently in mid training and a resident who had recently graduated from training of each specialty. Measured variables included interpreter's suspicion of presence of subarachnoid blood, side of the subarachnoid hemorrhage, location of the aneurysm, the aneurysm's proximity to vessel bifurcation, number of aneurysm(s), contour of aneurysm(s), presence of intraventricular hemorrhage (IVH), intracerebral hemorrhage (ICH), infarction, hydrocephalus and midline shift. To determine the inter-observer variability (IOV), weighted kappa values were calculated. There was moderate agreement on most of the CT scan findings among all observers. Substantial agreement was found amongst all observers for hydrocephalus, IVH, and ICH. Lowest agreement rates were seen in the location of aneurysm being supra or infra tentorial. There were, however, some noteworthy exceptions. There was substantial to almost perfect agreement between the radiology graduate and radiology resident on most CT findings. The lowest agreement was found between the neurosurgery graduate and the radiology graduate. Our study suggests that although agreements were seen in the interpretation of some of the radiological features of aSAH, there is still considerable IOV in the interpretation of most features among physicians belonging to different levels of training and different specialties. Whether these might affect management or outcome is unclear.

  9. Integrated Fellowship in Vascular Surgery and Intervention Radiology

    PubMed Central

    Messina, Louis M.; Schneider, Darren B.; Chuter, Timothy A. M.; Reilly, Linda M.; Kerlan, Robert K.; LaBerge, Jeane M.; Wilson, Mark W.; Ring, Ernest J.; Gordon, Roy L.

    2002-01-01

    Objective To evaluate an integrated fellowship in vascular surgery and interventional radiology initiated to train vascular surgeons in endovascular techniques and to train radiology fellows in clinical aspects of vascular diseases. Summary Background Data The rapid evolution of endovascular techniques for the treatment of vascular diseases requires that vascular surgeons develop proficiency in these techniques and that interventional radiologists develop proficiency in the clinical evaluation and management of patients who are best treated with endovascular techniques. In response to this need the authors initiated an integrated fellowship in vascular surgery and interventional radiology and now report their interim results. Methods Since 1999 vascular fellows and radiology fellows performed an identical year-long fellowship in interventional radiology. During the fellowship, vascular surgery and radiology fellows perform both vascular and nonvascular interventional procedures. Both vascular surgery and radiology-based fellows spend one quarter of the year on the vascular service performing endovascular aortic aneurysm repairs and acquiring clinical experience in the vascular surgery inpatient and outpatient services. Vascular surgery fellows then complete an additional year-long fellowship in vascular surgery. To evaluate the type and number of interventional radiology procedures, the authors analyzed records of cases performed by all interventional radiology and vascular surgery fellows from a prospectively maintained database. The attitudes of vascular surgery and interventional radiology faculty and fellows toward the integrated fellowship were surveyed using a formal questionnaire. Results During the fellowship each fellow performed an average of 1,201 procedures, including 808 vascular procedures (236 diagnostic angiograms, 70 arterial interventions, 59 diagnostic venograms, 475 venous interventions, and 43 hemodialysis graft interventions) and 393 nonvascular procedures. On average fellows performed 20 endovascular aortic aneurysm repairs per year. There was no significant difference between the vascular surgery and radiology fellows in either the spectrum or number of cases performed. Eighty-eight percent (23/26) of the questionnaires were completed and returned. Both interventional radiologists and vascular surgeons strongly supported the integrated fellowship model and favored continuation of the integrated program. Vascular surgery and interventional radiology faculty members wanted additional training in clinical vascular surgery for the radiology-based fellows. With the exception of the radiology fellows there was uniform agreement that vascular surgery fellows benefit from training in nonvascular aspects of interventional radiology. Conclusions Integration of vascular surgery and interventional radiology fellowships is feasible and is mutually beneficial to both disciplines. Furthermore, the integrated fellowship provides exceptional training for vascular surgery and interventional radiology fellows in all catheter-based techniques that far exceeds the minimum requirements for credentialing suggested by various professional societies. There is a clear need for cooperation and active involvement on the parts of the American Board of Radiology and the American Board of Surgery and its Vascular Board to create hybrid training programs that meet mutually agreed-on criteria that document sufficient acquisition of both the cognitive and technical skills required to manage patients undergoing endovascular procedures safely and effectively. PMID:12368668

  10. Results of a National Radiology Attending Physician Survey: The Effects of In-House Late and Overnight Attending Coverage on Radiology Resident Training.

    PubMed

    Hoffmann, Jason C; Singh, Ayushi; Mittal, Sameer; Peterkin, Yuri; Flug, Jonathan

    2016-01-01

    Over the past 10 years, there has been increased attending-level image interpretation during what has typically been considered the on-call period. The purpose of this study is to survey radiology attending physicians and assess their perceptions about how the presence of radiology attending physicians during the on-call period affects patient care and resident education. Two hundred eighty-eight radiology attendings completed the online survey. 70% believe that after hours final reads by radiology attendings improves patient care. 56% believe that this additional attending presence has a negative impact on the ability of graduating residents to efficiently interpret studies independently. A majority of radiology attending physicians in this study believe that increased in-house radiology attending coverage is harming resident training across the United States, yet also believe this attending presence is important for patient care. Additional studies are needed to quantify and further evaluate this effect, and develop strategies to address potential negative impacts on radiology resident education. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Estimating Radiological Doses to Predators Foraging in a Low-Level Radioactive Waste Management Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    L.Soholt; G.Gonzales; P.Fresquez

    2003-03-01

    Since 1957, Los Alamos National Laboratory has operated Area G as its low-level, solid radioactive waste management and disposal area. Although the waste management area is developed, plants, small mammals, and avian and mammalian predators still occupy the less disturbed and revegetated portions of the land. For almost a decade, we have monitored the concentrations of selected radionuclides in soils, plants, and small mammals at Area G. The radionuclides tritium, plutonium-238, and plutonium-239 are regularly found at levels above regional background in all three media. Based on radionuclide concentrations in mice collected from 1994 to 1999, we calculated doses tomore » higher trophic levels (owl, hawk, kestrel, and coyote) that forage on the waste management area. These predators play important functions in the regional ecosystems and are an important part of local Native American traditional tales that identify the uniqueness of their culture. The estimated doses are compared to Department of Energy's interim limit of 0.1 rad/day for the protection of terrestrial wildlife. We used exposure parameters that were derived from the literature for each receptor, including Environmental Protection Agency's exposure factors handbook. Estimated doses to predators ranged from 9E-06 to 2E-04 rad/day, assuming that they forage entirely on the waste management area. These doses are greater than those calculated for predators foraging exclusively in reference areas, but are still well below the interim dose limit. We believe that these calculated doses represent upper-bound estimates of exposure for local predators because the larger predators forage over areas that are much greater than the 63-acre waste management area. Based on these results, we concluded that predators foraging on this area do not face a hazard from radiological exposure under current site conditions.« less

  12. Anomalies in Proposed Regulations for the Release of Redundant Material from Nuclear and Non-nuclear Industries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menon, S.

    Now that increasing numbers of nuclear power stations are reaching the end of their commercially useful lives, the management of the large quantities of very low level radioactive material that arises during their decommissioning has become a major subject of discussion, with very significant economic implications. Much of this material can, in an environmentally advantageous manner, be recycled for reuse without radiological restrictions. Much larger quantities--2-3 orders of magnitude larger--of material, radiologically similar to the candidate material for recycling from the nuclear industry, arise in non-nuclear industries like coal, fertilizer, oil and gas, mining, etc. In such industries, naturally occurringmore » radioactivity is artificially concentrated in products, by-products or waste to form TENORM (Technologically Enhanced Naturally Occurring Radioactive Material). It is only in the last decade that the international community has become aware of the prevalence of T ENORM, specially the activity levels and quantities arising in so many nonnuclear industries. The first reaction of international organizations seems to have been to propose ''double'' standards for the nuclear and non-nuclear industries, with very stringent release criteria for radioactive material from the regulated nuclear industry and up to a hundred times more liberal criteria for the release/exemption of TENORM from the as yet unregulated non-nuclear industries. There are, however, many significant strategic issues that need to be discussed and resolved. An interesting development, for both the nuclear and non-nuclear industries, is the increased scientific scrutiny that the populations of naturally high background dose level areas of the world are being subject to. Preliminary biological studies have indicated that the inhabitants of such areas, exposed to many times the permitted occupational doses for nuclear workers, have not shown any differences in cancer mortality, life expectancy, chromosome aberrations or immune function, in comparison with those living in normal background areas. The paper discusses these and other strategic issues regarding the management of nuclear and non-nuclear radioactive material, underlining the need for consistency in regulatory treatment.« less

  13. The Northern Marshall Islands Radiological Survey: data and dose assessments.

    PubMed

    Robison, W L; Noshkin, V E; Conrado, C L; Eagle, R J; Brunk, J L; Jokela, T A; Mount, M E; Phillips, W A; Stoker, A C; Stuart, M L; Wong, K M

    1997-07-01

    Fallout from atmospheric nuclear tests, especially from those conducted at the Pacific Proving Grounds between 1946 and 1958, contaminated areas of the Northern Marshall Islands. A radiological survey at some Northern Marshall Islands was conducted from September through November 1978 to evaluate the extent of residual radioactive contamination. The atolls included in the Northern Marshall Islands Radiological Survey (NMIRS) were Likiep, Ailuk, Utirik, Wotho, Ujelang, Taka, Rongelap, Rongerik, Bikar, Ailinginae, and Mejit and Jemo Islands. The original test sites, Bikini and Enewetak Atolls, were also visited on the survey. An aerial survey was conducted to determine the external gamma exposure rate. Terrestrial (soil, food crops, animals, and native vegetation), cistern and well water samples, and marine (sediment, seawater, fish and clams) samples were collected to evaluate radionuclide concentrations in the atoll environment. Samples were processed and analyzed for 137Cs, 90Sr, 239+240Pu and 241Am. The dose from the ingestion pathway was calculated using the radionuclide concentration data and a diet model for local food, marine, and water consumption. The ingestion pathway contributes 70% to 90% of the estimated dose. Approximately 95% of the dose is from 137Cs. 90Sr is the second most significant radionuclide via ingestion. External gamma exposure from 137Cs accounts for about 10% to 30% of the dose. 239+240Pu and 241Am are the major contributors to dose via the inhalation pathway; however, inhalation accounts for only about 1% of the total estimated dose, based on surface soil levels and resuspension studies. All doses are computed for concentrations decay corrected to 1996. The maximum annual effective dose from manmade radionuclides at these atolls ranges from .02 mSv y(-1) to 2.1 mSv y(-1). The background dose in the Marshall Islands is estimated to be 2.4 mSv y(-1). The combined dose from both background and bomb related radionuclides ranges from slightly over 2.4 mSv y(-1) to 4.5 mSv y(-1). The 50-y integral dose ranges from 0.5 to 65 mSv.

  14. Cemento-osseous dysplasia in Jamaica: review of six cases.

    PubMed

    Ogunsalu, C; Miles, D

    2005-09-01

    Six cases of cemento-osseous dysplasia (COD) of the jaw bone in Jamaicans are reviewed. Five were documented over a 15-year period (1980-1995). These include a case of florid cemento-osseous dysplasia (previously called gigantiform cementoma). Three of the initial cases were histologically diagnosed as gigantiform cementoma. There was no indication in the patient's case file whether these were familial or non-familial. The other two cases were diagnosed histologically as periapical cemento-osseous dysplasia and cementoblastoma respectively. Based on the current understanding of the nature of florid-cemento-osseous dysplasia (FLCOD), a new case was diagnosed as such solely on radiological findings. This single case of FLCOD is reported and discussed against the background of other cemento-osseous lesions. Special emphasis is placed on the radiology of COD in this paper. The confirmative role of radiology without the need for histophathology and treatment for asymptomatic FLCOD is emphasized.

  15. Classification of radiological errors in chest radiographs, using support vector machine on the spatial frequency features of false- negative and false-positive regions

    NASA Astrophysics Data System (ADS)

    Pietrzyk, Mariusz W.; Donovan, Tim; Brennan, Patrick C.; Dix, Alan; Manning, David J.

    2011-03-01

    Aim: To optimize automated classification of radiological errors during lung nodule detection from chest radiographs (CxR) using a support vector machine (SVM) run on the spatial frequency features extracted from the local background of selected regions. Background: The majority of the unreported pulmonary nodules are visually detected but not recognized; shown by the prolonged dwell time values at false-negative regions. Similarly, overestimated nodule locations are capturing substantial amounts of foveal attention. Spatial frequency properties of selected local backgrounds are correlated with human observer responses either in terms of accuracy in indicating abnormality position or in the precision of visual sampling the medical images. Methods: Seven radiologists participated in the eye tracking experiments conducted under conditions of pulmonary nodule detection from a set of 20 postero-anterior CxR. The most dwelled locations have been identified and subjected to spatial frequency (SF) analysis. The image-based features of selected ROI were extracted with un-decimated Wavelet Packet Transform. An analysis of variance was run to select SF features and a SVM schema was implemented to classify False-Negative and False-Positive from all ROI. Results: A relative high overall accuracy was obtained for each individually developed Wavelet-SVM algorithm, with over 90% average correct ratio for errors recognition from all prolonged dwell locations. Conclusion: The preliminary results show that combined eye-tracking and image-based features can be used for automated detection of radiological error with SVM. The work is still in progress and not all analytical procedures have been completed, which might have an effect on the specificity of the algorithm.

  16. Analysis of operation UPSHOT-KNOTHOLE nuclear test BADGER radiological and meteorological data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quinn, V.E.

    1986-04-01

    This report describes the Weather Service Nuclear Support Office (WSNSO) analyses of the radiological and meteorological data collected for the BADGER nuclear test of Operation UPSHOT-KNOTHOLE. Inconsistencies in the radiological data and their resolution are discussed. The methods of normalizing the radiological data to a standard time, of converting the aerial data to equivalent ground-level values, and of estimating fallout-arrival times are presented. The meteorological situations on event day and the following day are described. A comparison of the WSNSO fallout analysis with an analysis performed during the 1950's is presented. The radiological data used to derive the WSNSO falloutmore » pattern are tabulated in an appendix.« less

  17. Use of alpha spectroscopy for conducting rapid surveys of transuranic activity on air sample filters and smears.

    PubMed

    Hayes, Robert B; Peña, Adan M; Goff, Thomas E

    2005-08-01

    This paper demonstrates the utility of a portable alpha Continuous Air Monitor (CAM) as a bench top scalar counter for multiple sample types. These include using the CAM to count fixed air sample filters and radiological smears. In counting radiological smears, the CAM is used very much like a gas flow proportional counter (GFPC), albeit with a lower efficiency. Due to the typically low background in this configuration, the minimum detectable activity for a 5-min count should be in the range of about 10 dpm which is acceptably below the 20 dpm limit for transuranic isotopes. When counting fixed air sample filters, the CAM algorithm along with other measurable characteristics can be used to identify and quantify the presence of transuranic isotopes in the samples. When the radiological control technician wants to take some credit from naturally occurring radioactive material contributions due to radon progeny producing higher energy peaks (as in the case with a fixed air sample filter), then more elaborate techniques are required. The techniques presented here will generate a decision level of about 43 dpm for such applications. The calibration for this application should alternatively be done using the default values of channels 92-126 for region of interest 1. This can be done within 10 to 15 min resulting in a method to rapidly evaluate air filters for transuranic activity. When compared to the 1-h count technique described by , the technique presented in the present work demonstrates a technique whereby more than two thirds of samples can be rapidly shown (within 10 to 15 min) to be within regulatory compliant limits. In both cases, however, spectral quality checks are required to insure sample self attenuation is not a significant bias in the activity estimates. This will allow the same level of confidence when using these techniques for activity quantification as is presently available for air monitoring activity quantification using CAMs.

  18. International Arctic Seas Assessment Project.

    PubMed

    Sjöblom, K L; Salo, A; Bewers, J M; Cooper, J; Dyer, R S; Lynn, N M; Mount, M E; Povinec, P P; Sazykina, T G; Schwarz, J; Scott, E M; Sivintsev, Y V; Tanner, J E; Warden, J M; Woodhead, D

    1999-09-30

    The International Atomic Energy Agency responded to the news that the former Soviet Union had dumped radioactive wastes in the shallow waters of the Arctic Seas, by launching the International Arctic Seas Assessment Project in 1993. The project had two objectives: to assess the risks to human health and to the environment associated with the radioactive wastes dumped in the Kara and Barents Seas; and to examine possible remedial actions related to the dumped wastes and to advise on whether they are necessary and justified. The current radiological situation in the Arctic waters was examined to assess whether there is any evidence for releases from the dumped waste. Potential future releases from the dumped wastes were predicted, concentrating on the high-level waste objects containing the major part of the radionuclide inventory of the wastes. Environmental transport of released radionuclides was modelled and the associated radiological impact on humans and the biota was assessed. The feasibility, costs and benefits of possible remedial measures applied to a selected high-level waste object were examined. Releases from identified dumped objects were found to be small and localised to the immediate vicinity of the dumping sites. Projected future annual doses to members of the public in typical local population groups were very small, less than 1 microSv--corresponding to a trivial risk. Projected future doses to a hypothetical group of military personnel patrolling the foreshore of the fjords in which wastes have been dumped were higher, up to 4 mSv/year, which still is of the same order as the average annual natural background dose. Moreover, since any of the proposed remedial actions were estimated to cost several million US$ to implement, remediation was not considered justified on the basis of potentially removing a collective dose of 10 man Sv. Doses calculated to marine fauna were insignificant, orders of magnitude below those at which detrimental effects on fauna populations might be expected to occur. Remediation was thus concluded not to be warranted on radiological grounds.

  19. 2008 Joint Chemical Biological, Radiological and Nuclear (CBRN) Conference and Exhibition

    DTIC Science & Technology

    2008-06-26

    Untitled Document 2008cbrn.html[5/16/ 2016 10:15:46 AM] 2008 Joint Chemical Biological, Radiological and Nuclear (CBRN) Conference & Exhibition... 2016 10:15:46 AM] Mr. Fred Crowson, Chief, Physical Science and Technology Division, Joint Science & Technology Office for Chemical and Biological... analysis Detect and measure alpha, beta, gamma, neutron, and x-ray emissions Levels A, B, and C capable Level A Level B 2-Jul-08 10 Extract Capabilities

  20. Evolution of the Preliminary Clinical Year and the Case for a Categorical Diagnostic Radiology Residency.

    PubMed

    Pfeifer, Cory M

    2016-07-01

    While other specialties traditionally utilizing a segregated clinical internship year have slowly progressed toward integrated training curricula, diagnostic radiology has been slow to adopt this path. The aim of this study was to analyze the trends in stand-alone preliminary clinical years as well as the shift toward categorical residencies currently being undertaken in other specialties. Advantages of mimicking the trends of other specialties and current integrated radiology programs are discussed. The perception of diagnostic radiology as a competitive specialty is explored, and the prospect of change as a recruiting tool is examined. Data assimilated by the NRMP from 1994 through 2016 were processed and analyzed. The total number of postgraduate year (PGY) 1 preliminary year programs has remained relatively constant over the past 10 years despite a gradual increase in overall NRMP applicants. The proportion of these programs offered as a transitional year declined from 31% in 1994 to 20% in 2016. The proportion of categorical anesthesiology positions gradually rose from 43% in 2007 to 70% in 2016. The fraction of categorical neurology positions increased from 30% in 2007 to 59% in 2016. The percentage of diagnostic radiology programs beginning at the PGY 1 level has been relatively constant at 12% to 14% since 2007. Dermatology has increased advanced (PGY 2) positions while decreasing categorical (PGY 1) positions. Those matching in diagnostic radiology have performed at a high level compared with the composite NRMP average since 2007. In the 2015 match, there were 65 diagnostic radiology programs that did not fill all of their offered positions. Of the institutions housing these programs, only 22% of them had preliminary internal medicine or transitional year positions available after the match. In response to the evolving nature of health care and graduate medical education, other specialties are gradually shifting toward curricular structures that begin at the PGY 1 level. By considering such a transition, diagnostic radiology would be well served to position itself as a valuable clinical specialty while maintaining a lesser dependence on other specialties to train its physicians. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. Quantitative analysis of the level of readability of online emergency radiology-based patient education resources.

    PubMed

    Hansberry, David R; D'Angelo, Michael; White, Michael D; Prabhu, Arpan V; Cox, Mougnyan; Agarwal, Nitin; Deshmukh, Sandeep

    2018-04-01

    The vast amount of information found on the internet, combined with its accessibility, makes it a widely utilized resource for Americans to find information pertaining to medical information. The field of radiology is no exception. In this paper, we assess the readability level of websites pertaining specifically to emergency radiology. Using Google, 23 terms were searched, and the top 10 results were recorded. Each link was evaluated for its readability level using a set of ten reputable readability scales. The search terms included the following: abdominal ultrasound, abdominal aortic aneurysm, aortic dissection, appendicitis, cord compression, CT abdomen, cholecystitis, CT chest, diverticulitis, ectopic pregnancy, epidural hematoma, dural venous thrombosis, head CT, MRI brain, MR angiography, MRI spine, ovarian torsion, pancreatitis, pelvic ultrasound, pneumoperitoneum, pulmonary embolism, subarachnoid hemorrhage, and subdural hematoma. Any content that was not written for patients was excluded. The 230 articles that were assessed were written, on average, at a 12.1 grade level. Only 2 of the 230 articles (1%) were written at the third to seventh grade recommended reading level set forth by the National Institutes of Health (NIH) and American Medical Association (AMA). Fifty-two percent of the 230 articles were written so as to require a minimum of a high school education (at least a 12th grade level). Additionally, 17 of the 230 articles (7.3%) were written at a level that exceeded an undergraduate education (at least a 16th grade level). The majority of websites with emergency radiology-related patient education materials are not adhering to the NIH and AMA's recommended reading levels, and it is likely that the average reader is not benefiting fully from these information outlets. With the link between health literacy and poor health outcomes, it is important to address the online content in this area of radiology, allowing for patient to more fully benefit from their online searches.

  2. Anesthesia Practice and Clinical Trends in Interventional Radiology: A European Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haslam, Philip J.; Yap, Bernard; Mueller, Peter R.

    Purpose: To determine current European practice in interventional radiology regarding nursing care, anesthesia, and clinical care trends.Methods: A survey was sent to 977 European interventional radiologists to assess the use of sedoanalgesia, nursing care, monitoring equipment, pre- and postprocedural care, and clinical trends in interventional radiology. Patterns of sedoanalgesia were recorded for both vascular and visceral interventional procedures. Responders rated their preferred level of sedoanalgesia for each procedure as follows: (a) awake/alert, (b) drowsy/arousable, (c) asleep/arousable, (d) deep sedation, and (e) general anesthesia. Sedoanalgesic drugs and patient care trends were also recorded. A comparison was performed with data derived frommore » a similar survey of interventional practice in the United States.Results: Two hundred and forty-three of 977 radiologists responded (25%). The total number of procedures analyzed was 210,194. The majority (56%) of diagnostic and therapeutic vascular procedures were performed at the awake/alert level of sedation, 32% were performed at the drowsy/arousable level, and 12% at deeper levels of sedation. The majority of visceral interventional procedures were performed at the drowsy/arousable level of sedation (41%), 29% were performed at deeper levels of sedation, and 30% at the awake/alert level. In general, more sedoanalgesia is used in the United States. Eighty-three percent of respondents reported the use of a full-time radiology nurse, 67% used routine blood pressure/pulse oximetry monitoring, and 46% reported the presence of a dedicated recovery area. Forty-nine percent reported daily patient rounds, 30% had inpatient hospital beds, and 51% had day case beds.Conclusion: This survey shows clear differences in the use of sedation for vascular and visceral interventional procedures. Many, often complex, procedures are performed at the awake/alert level of sedation in Europe, whereas deeper levels of sedation are used in the United States. Trends toward making interventional radiology a clinical specialty are evident, with 51% of respondents having day case beds, and 30% having inpatient beds.« less

  3. 2016 Annual Site Environmental Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finley, Virginia

    This report provides the U.S. Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory’s (PPPL) operations. The results of the 2016 environmental surveillance and monitoring program for PPPL’s are presented and discussed. The report also summarizes environmental initiatives, assessments, and community involvement programs that were undertaken in 2016. PPPL has engaged in fusion energy research since 1951. The vision of the Laboratory is to create innovations to make fusion power a practical reality – a clean,more » alternative energy source. 2016 marked the eighteenth year of National Spherical Torus Experiment and the first year of NSTX-U (Upgrade) operations. The NSTX-U Project is a collaboration among national laboratories, universities, and national and international research institutions and is a major element in the US Fusion Energy Sciences Program. Its design tests the physics principles of spherical torus (ST) plasmas, playing an important role in the development of smaller, more economical fusion reactors. NSTX-U began operations after its first upgrade that installed the new center stack magnets and second neutral beam, which would allow for hotter plasmas and greater field strength to maintain the fusion reaction longer. Due to operational issues with a poloidal coil, NSTX-U operated briefly in 2016. In 2016, PPPL’s radiological environmental monitoring program measured tritium in the air at the NSTX-U Stack and at on -site sampling stations. Using highly sensitive monitors, PPPL is capable of detecting small changes in the ambient levels of tritium. The operation of an in- stack monitor located on D-site is used to demonstrate compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations. Also included in PPPL’s radiological environmental monitoring program, are water monitoring – ground and surface, and waste waters. PPPL’s radiological monitoring program characterized the background levels of tritium in the environment; the data are presented in this report. Ground water monitoring continued under the New Jersey Department of Environmental Protection’s Site Remediation Program. PPPL monitored for non-radiological contaminants, mainly volatile organic compounds (components of chlorinated degreasing solvents). In 2016, PPPL was in compliance with its permit limits for surface and sanitary discharges, excepting two elevated chlorine-produced oxidant concentration. PPPL was honored with awards for its waste reduction and recycling program, and its “EPEAT” electronics purchasing for the third consecutive year.« less

  4. Readability of Online Patient Education Materials Related to IR.

    PubMed

    McEnteggart, Gregory E; Naeem, Muhammad; Skierkowski, Dorothy; Baird, Grayson L; Ahn, Sun H; Soares, Gregory

    2015-08-01

    To assess the readability of online patient education materials (OPEM) related to common diseases treated by and procedures performed by interventional radiology (IR). The following websites were chosen based on their average Google search return for each IR OPEM content area examined in this study: Society of Interventional Radiology (SIR), Cardiovascular and Interventional Radiological Society of Europe (CIRSE), National Library of Medicine, RadiologyInfo, Mayo Clinic, WebMD, and Wikipedia. IR OPEM content area was assessed for the following: peripheral arterial disease, central venous catheter, varicocele, uterine artery embolization, vertebroplasty, transjugular intrahepatic portosystemic shunt, and deep vein thrombosis. The following algorithms were used to estimate and compare readability levels: Flesch-Kincaid Grade Formula, Flesch Reading Ease Score, Gunning Frequency of Gobbledygook, Simple Measure of Gobbledygook, and Coleman-Liau Index. Data were analyzed using general mixed modeling. On average, online sources that required beyond high school grade-level readability were Wikipedia (15.0), SIR (14.2), and RadiologyInfo (12.4); sources that required high school grade-level readability were CIRSE (11.3), Mayo Clinic (11.0), WebMD (10.6), and National Library of Medicine (9.0). On average, OPEM on uterine artery embolization, vertebroplasty, varicocele, and peripheral arterial disease required the highest level of readability (12.5, 12.3, 12.3, and 12.2, respectively). The IR OPEM assessed in this study were written above the recommended sixth-grade reading level and the health literacy level of the average American adult. Many patients in the general public may not have the ability to read and understand health information in IR OPEM. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  5. Clinical and radiological analysis of a series of periapical cysts and periapical granulomas diagnosed in a Brazilian population

    PubMed Central

    Tavares, Daniel-Petitet; Rodrigues, Janderson-Teixeira; dos Santos, Teresa-Cristina-Ribeiro-Bartholomeu; Armada, Luciana

    2017-01-01

    Background Periapical cysts (PC) and periapical granulomas (PG) are the two most common chronic inflammatory periapical diseases, but their clinicoradiological characteristics can vary depending on the methods employed in each study. The aim of the present work was to analyze the clinical and radiological profile of a series of PC and PG diagnosed in a Brazilian population. Material and Methods The files of two Oral Pathology laboratories were reviewed and all cases diagnosed as PG and PC were selected for the study. Clinical and radiological information were retrieved and data were tabulated and descriptively and comparatively analyzed. Results Final sample was composed by 647 inflammatory periapical lesions, including 244 PG (38%) and 403 PC (62%). The number of women affected by PG was significantly higher than the number of women affected by PC (p=0.037). Anterior region of the maxilla was the most common affected area for both entities (39% of the cases), but the most common anatomical location of PG (anterior maxilla and posterior maxilla) was different from PC (anterior maxilla and posterior mandible) (p<0.0001). Upper lateral incisor was the most affected tooth. The mean radiological size of the PC was larger than the mean radiological size of the PG (p<0.0001) and PC showed well-defined radiological images more frequently than PG (p<0.0001). Conclusions PC were more common than PG, both showed predilection for adult females, most lesions affected predominantly the anterior maxilla and PC presented larger mean radiological diameter and well-defined images when compared with PG. Key words:Periapical granuloma, periapical cyst, radicular cyst, diagnosis, Oral Pathology. PMID:28149477

  6. Edith (1869-1938) and Florence (1870-1932) Stoney, two Irish sisters and their contribution to radiology during the World War I.

    PubMed

    Guy, Jean M

    2013-05-01

    Edith and Florence Stoney, two sisters born in Dublin and working in London, responded to the summons of suffragists and offered themselves for medical service in World War I. Each had a strong scientific background and experience that they were able to use in setting up and running radiological services in Belgium, France, Serbia and Macedonia. The British War Office was reluctant to employ women doctors but the work Florence and her colleagues achieved persuaded Sir Alfred Keogh that Florence should be the first woman doctor to be employed in a military hospital in England.

  7. Source detection at 100 meter standoff with a time-encoded imaging system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brennan, J.; Brubaker, E.; Gerling, M.

    Here, we present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ~1 mCi 252 Cf radiological source at 100 m standoff with 90% detection efficiency and 10% false positives against background in 12 min. As a result, this same detection efficiency is met at 15 s for a 40 m standoff, and 1.2 s for a 20 m standoff.

  8. Source detection at 100 meter standoff with a time-encoded imaging system

    DOE PAGES

    Brennan, J.; Brubaker, E.; Gerling, M.; ...

    2017-09-28

    Here, we present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ~1 mCi 252 Cf radiological source at 100 m standoff with 90% detection efficiency and 10% false positives against background in 12 min. As a result, this same detection efficiency is met at 15 s for a 40 m standoff, and 1.2 s for a 20 m standoff.

  9. An Aerial Radiological Survey of Selected Areas of the City of North Las Vegas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piotr Wasiolek

    2008-06-01

    As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey of selected areas of the city of North Las Vegas for the purpose of mapping natural radiation background and locating any man-made radioactive sources. Survey areas were selected in collaboration with the City Manager's office and included four separate areas: (1) Las Vegas Motor Speedway (10.6 square miles); (2) North Las Vegas Downtown Area (9.2 square miles); (3) I-15 Industrial Corridor (7.4 square miles); and (4) Future site ofmore » University of Nevada Las Vegas campus (17.4 square miles). The survey was conducted in three phases: Phase 1 on December 11-12, 2007 (Areas 1 and 2), Phase 2 on February 28, 2008 (Area 3), and Phase 3 on March 19, 2008 (Area 4). The total completed survey covered a total of 44.6 square miles. The flight lines (without the turns) over the surveyed areas are presented in Figures 1, 2, 3, and 4. A total of eight 2.5-hour-long flights were performed at an altitude of 150 ft above ground level (AGL) with 300 feet of flight-line spacing. Water line and test line flights were conducted over the Lake Mead and Government Wash areas to ensure quality control of the data. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data, in the form of gamma energy spectra, were collected continually (every second) over the course of the survey and were geo-referenced using a differential Global Positioning System. Collection of spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man-made radioisotopes. Spectral data can also be used to identify specific radioactive isotopes. As a courtesy service, with the approval of the U.S. Department of Energy, National Nuclear Security Administration, Nevada Site Office, RSL-Nellis is providing this summary to the office of the Mayor of the City of North Las Vegas along with the gross-count-based exposure rate and man-made count contour maps and GIS shape files in electronic format on a compact disk.« less

  10. Discrepancy in clinical versus radiological parameters describing deformity due to brace treatment for moderate idiopathic scoliosis

    PubMed Central

    Kotwicki, Tomasz; Kinel, Edyta; Stryla, Wanda; Szulc, Andrzej

    2007-01-01

    Background The shape of the torso in patients with idiopathic scoliosis is considered to reflect the shape of the vertebral column, however the direct correlation between parameters describing clinical deformity and those characterizing radiological curvature was reported to be weak. It is not clear if the management proposed for scoliosis (physiotherapy, brace, surgery) affects equally the shape of the axial skeleton and the surface of the body. The aim of the study was to compare clinical deformity of (1) idiopathic scoliosis girls being under brace treatment for radiological curves of 25 to 40 degrees and (2) non treated scoliotic girls matched for age and Cobb angle. Methods Cross-sectional study of 24 girls wearing the brace versus 26 girls without brace treatment, matched for age and Cobb angle. Hypothesis: Patients wearing the brace for more than 6 months, when comparing to patients without brace, may present different external morphology of the trunk, in spite of having similar Cobb angle. Material. Inclusion criteria: girls, idiopathic scoliosis, growing age (10–16 years), Cobb angle minimum 25°, maximum 40°. The braced group consisted of girls wearing a TLSO brace (Cheneau) for more than 6 months with minimum of 16 hours per day. The non-braced group consisted of girls first seen for their spinal deformity, previously not treated. The groups presented similar curve pattern. Methods. Scoliometer exam: angle of trunk rotation at three levels of the spine: upper thoracic, main thoracic, lumbar or thoracolumbar. The maximal angle was noted at each level and the sum of three levels was calculated. Posterior trunk symmetry index (POTSI) and Hump Sum were measured using surface topography. Results Cobb angle was 34.9° ± 4.8° in braced and 32.7° ± 4.9° in un-braced patients (difference not significant). The age was 14.1 ± 1.6 years in braced patients and 13.1 ± 1.9 years in un-braced group (p = 0.046). The value of angle of trunk rotation in the main curvature was 8.4° ± 2.7°in braced and 11.4° ± 2.7° in un-braced patients (difference extremely significant, p = 0.0003). The value of the sum of angles of trunk rotation at three levels of the trunk was 12.8° ± 4.6° in braced and 16.5° ± 3.8° in un-braced patients (difference very significant, p = 0.0038). The POTSI did not differ significantly between the groups (p = 0.78), the Hump Sum values were not quite different (p = 0.07). Conclusion (1) Adolescent girls wearing the brace for idiopathic scoliosis of 25 to 40 degrees of Cobb angle, reveal smaller clinical rotational deformity of their back than non-treated girls having similar radiological deformity. (2) Evaluation of the results of treatment for idiopathic scoliosis should consider parameters describing both clinical and radiological deformity. PMID:18053172

  11. A Novel Method for Quick Assessment of Internal And External Radiation Exposure in the Aftermath of a Large Radiological Incident.

    PubMed

    Korir, Geoffrey; Karam, P Andrew

    2018-06-11

    In the event of a significant radiological release in a major urban area where a large number of people reside, it is inevitable that radiological screening and dose assessment must be conducted. Lives may be saved if an emergency response plan and radiological screening method are established for use in such cases. Thousands to tens of thousands of people might present themselves with some levels of external contamination and/or the potential for internal contamination. Each of these individuals will require varying degrees of radiological screening, and those with a high likelihood of internal and/or external contamination will require radiological assessment to determine the need for medical attention and decontamination. This sort of radiological assessment typically requires skilled health physicists, but there are insufficient numbers of health physicists in any city to perform this function for large populations, especially since many (e.g., those at medical facilities) are likely to be engaged at their designated institutions. The aim of this paper is therefore to develop and describe the technical basis for a novel, scoring-based methodology that can be used by non-health physicists for performing radiological assessment during such radiological events.

  12. 35 Years of Experience From the American Association for Women Radiologists: Increasing the Visibility of Women in Radiology.

    PubMed

    Spalluto, Lucy B; Arleo, Elizabeth K; Macura, Katarzyna J; Rumack, Carol M

    2017-03-01

    Women radiologists remain in minority, unchanged for the past several decades. In 1981, the American Association for Women Radiologists (AAWR) was founded to address the problems that women radiologists were experiencing in being subordinate to male radiologists in the workplace and at the national level in organizations with respect to political power and financial compensation, as well as additional issues unique to women in radiology. The AAWR defined goals to meet the needs of women in radiology: improve the visibility of women radiologists, advance the professional and academic standing of women in radiology, and identify and address issues faced by women in radiology. AAWR efforts have included providing opportunities for career development and award recognition, hosting educational programs at national meetings, and publishing numerous manuscripts on issues faced by women in radiology. The AAWR recognizes that although there has been significant progress in the standing of women in radiology over the past 35 years, there is much room for improvement. The AAWR will continue to advocate for the needs of women in radiology. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Results of the survey activities and mobile gamma scanning in Monticello, Utah

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Little, C.A.; Berven, B.A.

    The town of Monticello, Utah, was once the site of an active mill which processed vanadium ore (1942 to 1948), and uranium ore (1948 to 1960). Properties in the vicinity of that mill have become contaminated with radioactive material from ore processing. The Radiological Survey Activities (RASA) group at Oak Ridge National Laboratory (ORNL) was requested by the Division of Remedial Action Projects (DRAP) in the Department of Energy (DOE) to: (1) identify potentially contaminated properties; (2) assess natural background radiation levels; and (3) rapidly assess the magnitude, extent, and type (i.e. ore, tailings, etc.) of contamination present on thesemore » properties (if any). This survey was conducted by RASA during April 1983. In addition to the 114 properties previously identified from historical information, the ORNL mobile gamma scanning van located 36 new properties exhibiting anomalous gamma radiation levels. Onsite surveys were conducted on 145 of the 150 total properties identified either historically or with the gamma scanning van. Of these 145 properties, 122 of them appeared to have some type of contaminated material present on them; however, only 48 appeared to be contaminated to the extent where they were in excess of Environmental Protection Agency (EPA) criteria (40 CFR 192). Twenty-one other properties were recommended for additional investigation (indoor gamma scanning and radon daughter measurements); of these, only ten required further analysis. This report provides the detailed data and analyses related to the radiological survey efforts performed by ORNL in Monticello, Utah.« less

  14. Development, Implementation, and Evaluation of a Structured Reporting Web Tool for Abdominal Aortic Aneurysms

    PubMed Central

    Karim, Sulafa; Fegeler, Christian; Boeckler, Dittmar; H Schwartz, Lawrence; Kauczor, Hans-Ulrich

    2013-01-01

    Background The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. Objective Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. Methods Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. Results A Web-based application for radiological “structured reporting” (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. Conclusions The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems. PMID:23956062

  15. Teleradiology in Singapore--taking stock and looking ahead.

    PubMed

    Cheng, Lionel T E; Ng, Samuel E S

    2006-08-01

    Teleradiology will have a significant impact on the delivery of healthcare and the practice of medicine. In order to ensure a positive outcome, the expected benefits, limitations and potential pitfalls of teleradiology must be carefully considered. For Singapore, teleradiology can be used to facilitate a quantum leap in the standards of radiological services. This can be achieved through the development of an integrated, nationwide, high-speed radiology network which will allow patients to have access to high-quality and responsive subspecialty radiology expertise located throughout the country. If judiciously implemented, teleradiology has the potential to propel Singapore radiology to an unprecedented level of professional quality and service delivery, and will provide the framework for sustainable radiological insourcing from other countries.

  16. The Importance of Proximal Fusion Level Selection for Outcomes of Multi-Level Lumbar Posterolateral Fusion

    PubMed Central

    Nam, Woo Dong

    2015-01-01

    Background There are few studies about risk factors for poor outcomes from multi-level lumbar posterolateral fusion limited to three or four level lumbar posterolateral fusions. The purpose of this study was to analyze the outcomes of multi-level lumbar posterolateral fusion and to search for possible risk factors for poor surgical outcomes. Methods We retrospectively analyzed 37 consecutive patients who underwent multi-level lumbar or lumbosacral posterolateral fusion with posterior instrumentation. The outcomes were deemed either 'good' or 'bad' based on clinical and radiological results. Many demographic and radiological factors were analyzed to examine potential risk factors for poor outcomes. Student t-test, Fisher exact test, and the chi-square test were used based on the nature of the variables. Multiple logistic regression analysis was used to exclude confounding factors. Results Twenty cases showed a good outcome (group A, 54.1%) and 17 cases showed a bad outcome (group B, 45.9%). The overall fusion rate was 70.3%. The revision procedures (group A: 1/20, 5.0%; group B: 4/17, 23.5%), proximal fusion to L2 (group A: 5/20, 25.0%; group B: 10/17, 58.8%), and severity of stenosis (group A: 12/19, 63.3%; group B: 3/11, 27.3%) were adopted as possible related factors to the outcome in univariate analysis. Multiple logistic regression analysis revealed that only the proximal fusion level (superior instrumented vertebra, SIV) was a significant risk factor. The cases in which SIV was L2 showed inferior outcomes than those in which SIV was L3. The odds ratio was 6.562 (95% confidence interval, 1.259 to 34.203). Conclusions The overall outcome of multi-level lumbar or lumbosacral posterolateral fusion was not as high as we had hoped it would be. Whether the SIV was L2 or L3 was the only significant risk factor identified for poor outcomes in multi-level lumbar or lumbosacral posterolateral fusion in the current study. Thus, the authors recommend that proximal fusion levels be carefully determined when multi-level lumbar fusions are considered. PMID:25729522

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Virginia L. Finley

    The purpose of this report is to provide the U.S. Department of Energy (DOE) and the public with information on the level of radioactive and nonradioactive pollutants (if any) that are added to the environment as a result of the Princeton Plasma Physics Laboratory's (PPPL) operations. The results of the 2001 environmental surveillance and monitoring program for PPPL are presented and discussed. The report also summarizes environmental initiatives, assessments, and programs that were undertaken in 2001. PPPL has engaged in fusion energy research since 1951. The vision of the Laboratory is to create innovations to make fusion power a practicalmore » reality--a clean, alternative energy source. The Year 2001 marked the third year of National Spherical Torus Experiment (NSTX) operations and Tokamak Fusion Test Reactor (TFTR) dismantlement and deconstruction activities. A collaboration among fourteen national laboratories, universities, and research institutions, the NSTX is a major element in the U.S. Fusion Energy Sciences Program. It has been designed to test the physics principles of spherical torus (ST) plasmas. The ST concept could play an important role in the development of smaller, more economical fusion reactors. In 2001, PPPL's radiological environmental monitoring program measured tritium in the air at on- and off-site sampling stations. PPPL is capable of detecting small changes in the ambient levels of tritium by using highly sensitive monitors. The operation of an in-stack monitor located on D-site is a requirement of the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations; also included in PPPL's radiological environmental monitoring program, are water monitoring--precipitation, ground-, surface-, and waste-waters. PPPL's radiological monitoring program characterized the ambient, background levels of tritium in the environment and from the D-site stack; the data are presented in this report. Groundwater monitoring continue d under a voluntary agreement with the New Jersey Department of Environmental Protection. PPPL monitored for the presence of nonradiological contaminants, mainly volatile organic compounds (components of degreasing solvents). Monitoring revealed the low levels of volatile organic compounds in an area adjacent to PPPL. In 2001, PPPL was in compliance with its permit limits for surface and sanitary discharges and had no reportable releases. Additionally, as part of DOE's program for the purchase of recycled content and other environmentally preferred products, PPPL has ranked in the excellent category of 80 to 90% of the goal.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Virginia L. Finley

    The results of the 2000 environmental surveillance and monitoring program for the Princeton Plasma Physics Laboratory (PPPL) are presented and discussed. The purpose of this report is to provide the U.S. Department of Energy and the public with information on the level of radioactive and nonradioactive pollutants (if any) that are added to the environment as a result of PPPL's operations. The report also summarizes environmental initiatives, assessments, and programs that were undertaken in 2000. The Princeton Plasma Physics Laboratory has engaged in fusion energy research since 1951. The long-range goal of the U.S. Magnetic Fusion Energy Research Program ismore » to create innovations to make fusion power a practical reality -- an alternative energy source. The year 2000 marked the second year of National Spherical Torus Experiment (NSTX) operations and Tokamak Fusion Test Reactor (TFTR) dismantlement and deconstruction activities. A collaboration among fourteen national laboratories, universities, and research institutions, the NSTX is a major element in the U.S. Fusion Energy Sciences Program. It has been designed to test the physics principles of spherical torus (ST) plasmas. The ST concept could play an important role in the development of smaller, more economical fusion power plants. With its completion within budget and ahead of its target schedule, NSTX first plasma occurred on February 12, 1999. In 2000, PPPL's radiological environmental monitoring program measured tritium in the air at on-site and off-site sampling stations. PPPL is capable of detecting small changes in the ambient levels of tritium by using highly sensitive monitors. The operation of an in-stack monitor located on D-site is a requirement of the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations with limits set by the Environmental Protection Agency (EPA). Also included in PPPL's radiological environmental monitoring program, are precipitation, surface, ground, a nd waste water monitoring. Groundwater investigations continued under a voluntary agreement with the New Jersey Department of Environmental Protection. PPPL monitored for the presence of nonradiological contaminants, mainly volatile organic compounds (components of degreasing solvents). Monitoring revealed the presence of low levels of volatile organic compounds in an area adjacent to PPPL. Also, PPPL's radiological monitoring program characterized the ambient, background levels of tritium in the environment and from the D-site stack; the data are presented in this report.« less

  19. Mobile technology in radiology resident education.

    PubMed

    Korbage, Aiham C; Bedi, Harprit S

    2012-06-01

    The authors hypothesized that ownership of a mobile electronic device would result in more time spent learning radiology. Current trends in radiology residents' studying habits, their use of electronic and printed radiology learning resources, and how much of the funds allotted to them are being used toward printed vs electronic education tools were assessed in this study. A survey study was conducted among radiology residents across the United States from June 13 to July 5, 2011. Program directors listed in the Association of Program Directors in Radiology e-mail list server received an e-mail asking for residents to participate in an online survey. The questionnaire consisted of 12 questions and assessed the type of institution, the levels of training of the respondents, and book funds allocated to residents. It also assessed the residents' study habits, access to portable devices, and use of printed and electronic radiology resources. Radiology residents are adopters of new technologies, with 74% owning smart phones and 37% owning tablet devices. Respondents spend nearly an equal amount of time learning radiology from printed textbooks as they do from electronic resources. Eighty-one percent of respondents believe that they would spend more time learning radiology if provided with tablet devices. There is considerable use of online and electronic resources and mobile devices among the current generation of radiology residents. Benefits, such as more study time, may be obtained by radiology programs that incorporate tablet devices into the education of their residents. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  20. Formerly utilized MED/AEC sites remedial action program. Radiological survey of The George Herbert Jones Chemical Laboratory, The University of Chicago, Chicago, Illinois, June 13-17, 1977

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wynveen, R.A.; Smith, W.H.; Mayes, C.B.

    A comprehensive radiological survey was conducted at George Herbert Jones Chemical Laboratory at the University of Chicago, Chicago, Illinois. Radiochemistry for the MED/AEC project was performed in this building in the 1940s. The building is now used as laboratories, offices, and classrooms. The survey was undertaken to determine the location and quantities of any radioactive materials remaining from the MED/AEC operations. Forty-three spots of contamination possibly resulting from MED/AEC occupancy in 17 rooms exceeded the allowable limits as given in the ANSI Standard N13.12. Under current use conditions, the potential for radiation exposure to occupants of this building from thesemore » sources of contamination is remote. Concentrations of radon daughters in the air of the building, as measured with grab-sampling techniques, were below the limit of 0.01 WL above background as given in the Surgeon General's Guidelines. No long-lived radionuclides were detected in any air sample. Concentrations of radionuclides in soil samples from near the laboratory generally indicated background levels. In order to reduce the potential for radiation exposure, remedial measures such as stabilization of the contamination in place would be applicable as a short-term measure. In order to reduce the risk in the event that building modifications take place in the future, health physics procedures and coverage are recommended. The long-term solution would involve decontamination by removal of the radioactive residues from the 17 rooms or areas where contamination possibly resulting from MED/AEC activities was detected.« less

  1. Overview of ICRP Committee 3: protection in medicine.

    PubMed

    Vañó, E; Miller, D L; Rehani, M M

    2016-06-01

    Committee 3 of the International Commission on Radiological Protection (ICRP) develops recommendations and guidance for protection of patients, staff, and the public against radiation exposure when ionising radiation is used for medical diagnosis, therapy, or biomedical research. This paper presents a summary of the work that Committee 3 has accomplished over the past few years, and also describes its current work. The most recent reports published by the Commission that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (Publication 129), 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (Publication 128, in cooperation with Committee 2), 'Radiological protection in ion beam radiotherapy' (Publication 127), 'Radiological protection in paediatric diagnostic and interventional radiology' (Publication 121), 'Radiological protection in cardiology' (Publication 120), and 'Radiological protection in fluoroscopically guided procedures outside the imaging department' (Publication 117). A new report on diagnostic reference levels in medical imaging will provide specific advice for interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and hybrid (multi-modality) imaging procedures, and is expected to be published in 2016. Committee 3 is also working on guidance for occupational radiological protection in brachytherapy, and on guidance on occupational protection issues in interventional procedures, paying particular attention to the 2011 Commission's recommendations on the occupational dose limit for the lens of the eye (Publication 118). Other reports in preparation deal with justification, radiological protection in therapy with radiopharmaceuticals, radiological protection in medicine as related to individual radiosusceptibility, appropriate use of effective dose (in cooperation with other Committees), and guidance for healthcare practitioners on radiological and patient protection. Committee 3 has also suggested specific priorities for research on radiological protection in medicine to the Commission. © The International Society for Prosthetics and Orthotics.

  2. Radiology and social media: are private practice radiology groups more social than academic radiology departments?

    PubMed

    Glover, McKinley; Choy, Garry; Boland, Giles W; Saini, Sanjay; Prabhakar, Anand M

    2015-05-01

    This study assesses the prevalence of use of the most commonly used social media sites among private radiology groups (PRGs) and academic radiology departments (ARDs). The 50 largest PRGs and the 50 ARDs with the highest level of funding from the National Institutes of Health were assessed for presence of a radiology-specific social media account on Facebook, Twitter, Instagram, Pinterest, YouTube, and LinkedIn. Measures of organizational activity and end-user activity were collected, including the number of posts and followers, as appropriate; between-group comparisons were performed. PRGs adopted Facebook 12 months earlier (P = .02) and Twitter 18 months earlier (P = .02) than did ARDs. A total of 76% of PRGs maintained ≥1 account on the social media sites included in the study, compared with 28% of ARDs (P < .0001). The prevalence of having an account on the social media sites for PRGs was: Facebook, 66%; LinkedIn, 56%; Twitter, 42%; YouTube, 20%; Pinterest, 4%; and Instagram, 2%. The prevalence of radiology-specific social media accounts for ARDs was: Facebook, 18%; LinkedIn, 0%; Twitter, 24%; YouTube, 6%; Pinterest, 0%; and Instagram, 0%. There was no significant difference between ARDs and PRGs in measures of end-user or organizational activity on Facebook or Twitter. Use of social media in health care is emerging as mainstream, with PRGs being early adopters of Facebook and Twitter in comparison with ARDs. Competitive environments and institutional policies may be strong factors that influence how social media is used by radiologists at the group and department levels. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. 10 CFR 835.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Reasonably Achievable,” which is the approach to radiation protection to manage and control exposures (both... (Sv)) (1 rem = 0.01 Sv) or a committed equivalent dose of 50 rems (0.5 Sv) to any individual organ or... radiological control. Background means radiation from: (1) Naturally occurring radioactive materials which have...

  4. 10 CFR 835.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Reasonably Achievable,” which is the approach to radiation protection to manage and control exposures (both... (Sv)) (1 rem = 0.01 Sv) or a committed equivalent dose of 50 rems (0.5 Sv) to any individual organ or... radiological control. Background means radiation from: (1) Naturally occurring radioactive materials which have...

  5. 10 CFR 835.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Reasonably Achievable,” which is the approach to radiation protection to manage and control exposures (both... (Sv)) (1 rem = 0.01 Sv) or a committed equivalent dose of 50 rems (0.5 Sv) to any individual organ or... radiological control. Background means radiation from: (1) Naturally occurring radioactive materials which have...

  6. 10 CFR 835.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Reasonably Achievable,” which is the approach to radiation protection to manage and control exposures (both... (Sv)) (1 rem = 0.01 Sv) or a committed equivalent dose of 50 rems (0.5 Sv) to any individual organ or... radiological control. Background means radiation from: (1) Naturally occurring radioactive materials which have...

  7. 10 CFR 835.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Reasonably Achievable,” which is the approach to radiation protection to manage and control exposures (both... (Sv)) (1 rem = 0.01 Sv) or a committed equivalent dose of 50 rems (0.5 Sv) to any individual organ or... radiological control. Background means radiation from: (1) Naturally occurring radioactive materials which have...

  8. 78 FR 40479 - Declaration That Circumstances Exist Justifying Authorization of Emergency Use of All Oral...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-05

    .... ACTION: Notice. SUMMARY: The Secretary of Homeland Security determined on September 23, 2008, that there... specified biological, chemical, radiological, or nuclear agent or agents--in this case, Bacillus anthracis...). SUPPLEMENTARY INFORMATION: I. Background On September 23, 2008, former Secretary of Homeland Security, [[Page...

  9. 162 E. Ontario St., January 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. Readings for the trench were from 3,000 cpm to 6,300 cpm. No detections were above the field screening limit, equivalent to the USEPA action level for the Streeterville.

  10. Most Common Publication Types in Radiology Journals:: What is the Level of Evidence?

    PubMed

    Rosenkrantz, Andrew B; Pinnamaneni, Niveditha; Babb, James S; Doshi, Ankur M

    2016-05-01

    This study aimed to assess the most common publication types in radiology journals, as well as temporal trends and association with citation frequency. PubMed was searched to extract all published articles having the following "Publication Type" indices: "validation studies," "meta-analysis," "clinical trial," "comparative study," "evaluation study," "guideline," "multicenter study," "randomized study," "review," "editorial," "case report," and "technical report." The percentage of articles within each category published within clinical radiology journals was computed. Normalized percentages for each category were also computed on an annual basis. Citation counts within a 2-year window following publication were obtained using Web of Science. Overall trends were assessed. Publication types with the highest fraction in radiology journals were technical reports, evaluation studies, and case reports (4.8% to 5.8%). Publication types with the lowest fraction in radiology journals were randomized trials, multicenter studies, and meta-analyses (0.8% to 1.5%). Case reports showed a significant decrease since 1999, with accelerating decline since 2007 (P = 0.002). Publication types with highest citation counts were meta-analyses, guidelines, and multicenter studies (8.1 ± 10.7 to 12.9 ± 5.1). Publication types with lowest citation counts were case reports, editorials, and technical reports (1.4 ± 2.4 to 2.9 ± 4.3). The representation in radiology journals and citation frequency of the publication types showed weak inverse correlation (r = -0.372). Radiology journals have historically had relatively greater representation of less frequently cited publication types. Various strategies, including methodological training, multidisciplinary collaboration, national support networks, as well as encouragement of higher level of evidence by funding agencies and radiology journals themselves, are warranted to improve the impact of radiological research. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  11. Comparison of the radiological and chemical toxicity of lead

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beitel, G.A.; Mott, S.

    1995-03-01

    This report estimates the worst-case radiological dose to an individual from ingested lead containing picocurie levels of radionuclides and then compares the calculated radiological health effects to the chemical toxic effects from that same lead. This comparison provides an estimate of the consequences of inadvertently recycling, in the commercial market, lead containing nominally undetectable concentrations of radionuclides. Quantitative expressions for the radiological and chemical toxicities of lead are based on concentrations of lead in the blood stream. The result shows that the chemical toxicity of lead is a greater health hazard, by orders of magnitude, than any probable companion radiationmore » dose.« less

  12. A national survey exploring UK trainees' perceptions, core training experience, and decisions to pursue advanced training in breast radiology.

    PubMed

    Lowes, S; Bydder, M; Sinnatamby, R

    2017-11-01

    To investigate UK radiology trainees' perceptions of breast radiology and the factors that influenced their decision whether or not to choose breast radiology as an area of special interest. An online survey was compiled and distributed to all UK specialty trainees in clinical radiology via the Royal College of Radiologists Junior Radiologists' Forum (JRF) regional representatives. There were 275 respondents, representing 22% of all UK radiology trainees. Responses were received from all regions. A significant factor identified in influencing whether or not trainees decide to pursue advanced training in breast radiology is the timing and quality of their initial core training experience. Specific positive aspects of breast radiology that were repeatedly identified included the high level of patient contact and frequent use of interventional procedures. Recurring negative aspects of breast radiology included isolation from general radiology and finding the subject matter boring. Breast radiology faces a significant workforce shortfall that is predicted to worsen in the coming years. There has never been a greater need to recruit specialty trainees into this field, and action is urgently needed to help ensure the sustainability of breast services and drive further improvements to patient care. The findings from this survey should be regarded as a challenge to all breast radiologists to engage with trainees from an early stage in their training and to enthuse them with the many positive aspects of a career in breast radiology. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Does outsourcing paramedical departments of teaching hospitals affect educational status of the students?

    PubMed Central

    Moslehi, Shandiz; Atefimanesh, Pezhman; Sarabi Asiabar, Ali; Ahmadzadeh, Nahal; Kafaeimehr, Mohamadhosein; Emamgholizadeh, Saeid

    2016-01-01

    Background: There is an increasing trend of outsourcing public departments. Teaching hospitals also outsourced some of their departments to private sectors. The aim of this study was to investigate and compare the educational status of students in public and outsourced departments of teaching hospitals affiliated to Iran University of Medical Sciences. Methods: This study was conducted in six teaching hospitals of Iran University of Medical Sciences, which had public and outsourced teaching departments in 2015. One hundred fifty students from the departments of radiology, physiotherapy and laboratory participated in this study and their perceptions about their educational status were assessed. A valid and reliable questionnaire was used; participation in the study was voluntary. Descriptive statistics such as mean (SD), t-test and Kolmogorov-Smirnov were used. Results: No difference was detected between the educational status of students in public and outsourced departments of radiology, physiotherapy and laboratory (p>0.05). Conclusion: Based on the students’ perception, the private sectors could maintain the educational level of the teaching departments similar to the public departments. It is recommended to involve all the stakeholders such as hospital administrators, academic staff and students in the decision- making process when changes in teaching environments are being considered. PMID:27683645

  14. Trends in radiology and experimental research.

    PubMed

    Sardanelli, Francesco

    2017-01-01

    European Radiology Experimental , the new journal launched by the European Society of Radiology, is placed in the context of three general and seven radiology-specific trends. After describing the impact of population aging, personalized/precision medicine, and information technology development, the article considers the following trends: the tension between subspecialties and the unity of the discipline; attention to patient safety; the challenge of reproducibility for quantitative imaging; standardized and structured reporting; search for higher levels of evidence in radiology (from diagnostic performance to patient outcome); the increasing relevance of interventional radiology; and continuous technological evolution. The new journal will publish not only studies on phantoms, cells, or animal models but also those describing development steps of imaging biomarkers or those exploring secondary end-points of large clinical trials. Moreover, consideration will be given to studies regarding: computer modelling and computer aided detection and diagnosis; contrast materials, tracers, and theranostics; advanced image analysis; optical, molecular, hybrid and fusion imaging; radiomics and radiogenomics; three-dimensional printing, information technology, image reconstruction and post-processing, big data analysis, teleradiology, clinical decision support systems; radiobiology; radioprotection; and physics in radiology. The journal aims to establish a forum for basic science, computer and information technology, radiology, and other medical subspecialties.

  15. Uranium in groundwater--Fertilizers versus geogenic sources.

    PubMed

    Liesch, Tanja; Hinrichsen, Sören; Goldscheider, Nico

    2015-12-01

    Due to its radiological and toxicological properties even at low concentration levels, uranium is increasingly recognized as relevant contaminant in drinking water from aquifers. Uranium originates from different sources, including natural or geogenic, mining and industrial activities, and fertilizers in agriculture. The goal of this study was to obtain insights into the origin of uranium in groundwater while differentiating between geogenic sources and fertilizers. A literature review concerning the sources and geochemical processes affecting the occurrence and distribution of uranium in the lithosphere, pedosphere and hydrosphere provided the background for the evaluation of data on uranium in groundwater at regional scale. The state of Baden-Württemberg, Germany, was selected for this study, because of its hydrogeological and land-use diversity, and for reasons of data availability. Uranium and other parameters from N=1935 groundwater monitoring sites were analyzed statistically and geospatially. Results show that (i) 1.6% of all water samples exceed the German legal limit for drinking water (10 μg/L); (ii) The range and spatial distribution of uranium and occasional peak values seem to be related to geogenic sources; (iii) There is a clear relation between agricultural land-use and low-level uranium concentrations, indicating that fertilizers generate a measurable but low background of uranium in groundwater. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. System-Level Process Change Improves Communication and Follow-Up for Emergency Department Patients With Incidental Radiology Findings.

    PubMed

    Baccei, Steven J; Chinai, Sneha A; Reznek, Martin; Henderson, Scott; Reynolds, Kevin; Brush, D Eric

    2018-04-01

    The appropriate communication and management of incidental findings on emergency department (ED) radiology studies is an important component of patient safety. Guidelines have been issued by the ACR and other medical associations that best define incidental findings across various modalities and imaging studies. However, there are few examples of health care facilities designing ways to manage incidental findings. Our institution aimed to improve communication and follow-up of incidental radiology findings in ED patients through the collaborative development and implementation of system-level process changes including a standardized loop-closure method. We assembled a multidisciplinary team to address the nature of these incidental findings and designed new workflows and operational pathways for both radiology and ED staff to properly communicate incidental findings. Our results are based on all incidental findings received and acknowledged between November 1, 2016, and May 30, 2017. The total number of incidental findings discovered was 1,409. Our systematic compliance fluctuated between 45% and 95% initially after implementation. However, after overcoming various challenges through optimization, our system reached a compliance rate of 93% to 95%. Through the implementation of our new, standardized communication system, a high degree of compliance with loop closure for ED incidental radiology findings was achieved at our institution. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. Natural radioactivity in soils of the state of Rio de Janeiro (Brazil): Radiological characterization and relationships to geological formation, soil types and soil properties.

    PubMed

    Ribeiro, F C A; Silva, J I R; Lima, E S A; do Amaral Sobrinho, N M B; Perez, D V; Lauria, D C

    2018-02-01

    Located in the south-western part of Brazil, the state of Rio de Janeiro is geotectonically contained within a complex structural province that resulted in the amalgamation of the Western Gondwana Paleocontinent. To undertake an extensive radiological characterization of this complex geological province and investigate the influence of bedrock, soil type and soil chemical-physical characteristics on natural radionuclide levels in soils, 259 surface soil samples were collected that encompassed the main soil types and geological formations throughout the state. Gamma spectrometry analysis of the samples resulted in median values of 114 Bq.kg -1 for 40 K, 32 Bq.kg -1 for 226 Ra and 74 Bq.kg -1 for 228 Ra. The median value for 226 Ra was similar to the world median value for soils, the 40 K value was well below the worldwide value, and that for 228 Ra exceeded the world median value. The intense weathering caused by the high rainfall rates and high temperatures may be responsible for the low levels of 40 K in the soils, of which the strongly acidic and clayey soils are markedly K-depleted. A soil from a high-grade metamorphic rock (granulite) presented the lowest 226 Ra (18 Bq.kg -1 ) content, whereas the highest levels for 226 Ra (92 Bq.kg -1 ) and 228 Ra (139 Bq.kg - 1) were observed in a young soil enriched in primary minerals (Leptsol). A lowland soil (Gleysol) showed the highest median of 40 K (301 Bq.kg -1 ). Strongly acidic soils tended to present high amounts of 226 Ra, and sandy soils tended to contain low levels of 228 Ra. The external radiation dose indicates that the state has a background radiation level within the natural range. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. The predictable swarm: staying on top of radiology's cyclical staffing "bug".

    PubMed

    Ryan, Mary Jane

    2005-01-01

    Partners HealthCare System in Boston, MA, took some progressive and bold steps to address the recent staffing shortages in radiology. By addressing the shortage at the system level versus the individual hospital level, Partners was able to successfully recruit and support more than 80 new radiologic technologists from initial interest through graduation in 2 years. The recruitment effort helped reduce the utilization of temporary/agency personnel that cost the system more than dollar 6 million in 2001. The system utilized a multi-disciplinary team of professionals at many levels in the organization to achieve significant results in a relatively short period of time. Further, the organization channeled all available resources, including a grant from the US Department of Labor (DOL). The Boston Private Industry Council (BPIC), a local organization well known to the Partners HealthCare community benefits and human resources departments, managed the DOL grant. At least 64 of the first 80 graduates have accepted positions within Partners HealthCare radiology departments. The organization has further populated a database of more than 1,000 interested candidates, some of whom are currently in school and preparing for a future career in radiology, hopefully within the Partners HealthCare System. Partners HealthCare has managed to maintain a diversity rate at over 25% people of color by utilizing targeted recruiting efforts. Partners plans to continue to offer scholarships and other methods of support and career laddering for radiologic technologists in order to continue to meet staffing needs well in to the future. Partners HealthCare developed and implemented a "grow your own" strategy, and the system's leaders hold the philosophy that workforce development is a long-term investment requiring a flexible, permanent plan to stay ahead of the clinical staffing curve.

  19. Update on the diagnostic radiology employment market: findings through 2005.

    PubMed

    Licurse, Adam; Saket, Daniel D; Sunshine, Jonathan H; Maynard, C Douglas; Forman, Howard P

    2006-09-01

    The purpose of this study is to analyze and summarize the latest data describing the diagnostic radiologist employment market. Three sources of data--vacancies in academic radiology departments as of July 1, 2005; the ratio of job listings to job seekers at a major placement service; and the number of positions advertised in the American Journal of Roentgenology and Radiology-are presented and compared with previous data. Vacancies in academic departments averaged 4.5 in 2005, an increase of 16% from 2004 but a decrease of 16% from the 2001 peak. Vacancies increased from 2004 in all specialties except nuclear medicine and "other," and vacancies decreased from 2001 in all specialties except pediatric radiology and purely research positions. Job listings per job seeker increased 8% from 2004 but remain far below peak levels. The total number of positions advertised decreased by 6% from 2004, reaching the lowest level since 1998. In 2005, 42% of the total advertised jobs were academic, as compared with 45% in 2004. Proportional decreases were seen between 2004 and 2005 in total advertisements per region except the Northwest and California. The largest proportional increases in subspecialties occurred in general radiology, abdominal imaging, and "other." Data from the American College of Radiology Professional Bureau and a survey of academic radiology departments show an increased demand for diagnostic radiologists in 2005, whereas data from the help wanted index show a decrease. In addition, the regional distribution of advertisements and the proportion of advertisements for certain specialties have shown some shifting in 2005. We believe the job market remains strong, with regional and specialty shifting.

  20. Update on the diagnostic radiologist employment market: findings through 2004.

    PubMed

    Saket, Daniel D; Nwanze, Chukwuemeka C; Maynard, C Douglas; Sunshine, Jonathan H; Forman, Howard P

    2005-12-01

    The objective of this article is to summarize the latest information concerning the diagnostic radiologist employment market. Three sources of data are presented and compared with previous data: vacancies in academic radiology departments as of July; the ratio of job listings to job seekers at a major placement service; and the number of positions advertised in Radiology and the American Journal of Roentgenology. Vacancies in academic radiology departments averaged 3.9 in 2004, down 29%, and decreased for all subspecialties as compared with 2001, but the number of vacancies remained very similar to that for 2003. Job listings per job seeker were 1.1 in 2004, stable over the past 2 years but at the lowest level since 1997. The overall number of positions advertised declined by 14% in 2003 compared with 2002 and by an additional 17% in 2004, reaching the lowest level since 1998. In 2004, 45.3% of positions advertised were academic. Comparing 2003-2004 with 2001-2002, all geographic regions exhibited absolute declines in advertisements except the Northeast, which showed a 1.5% increase. Absolute increases occurred for musculoskeletal and emergency radiology positions. Statistically significant proportional decreases occurred for general radiology, vascular/interventional radiology, and pediatric radiology. Three separate data sources confirm a substantial and broad-based multiyear decline in the strength of the demand for diagnostic radiologists, with some shifting in relative demand for subspecialties. It is not clear if the decrease continued in 2004 or if 2004 demand was similar to that of 2003. Data are relative and do not indicate the employment market is weak in absolute terms.

  1. An aerial radiological survey of the Nevada Test Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendricks, T J; Riedhauser, S R

    1999-12-01

    A team from the Remote Sensing Laboratory conducted an aerial radiological survey of the US Department of Energy's Nevada Test Site including three neighboring areas during August and September 1994. The survey team measured the terrestrial gamma radiation at the Nevada Test Site to determine the levels of natural and man-made radiation. This survey included the areas covered by previous surveys conducted from 1962 through 1993. The results of the aerial survey showed a terrestrial background exposure rate that varied from less than 6 microroentgens per hour (mR/h) to 50 mR/h plus a cosmic-ray contribution that varied from 4.5 mR/hmore » at an elevation of 900 meters (3,000 feet) to 8.5 mR/h at 2,400 meters (8,000 feet). In addition to the principal gamma-emitting, naturally occurring isotopes (potassium-40, thallium-208, bismuth-214, and actinium-228), the man-made radioactive isotopes found in this survey were cobalt-60, cesium-137, europium-152, protactinium-234m an indicator of depleted uranium, and americium-241, which are due to human actions in the survey area. Individual, site-wide plots of gross terrestrial exposure rate, man-made exposure rate, and americium-241 activity (approximating the distribution of all transuranic material) are presented. In addition, expanded plots of individual areas exhibiting these man-made contaminations are given. A comparison is made between the data from this survey and previous aerial radiological surveys of the Nevada Test Site. Some previous ground-based measurements are discussed and related to the aerial data. In regions away from man-made activity, the exposure rates inferred from the gamma-ray measurements collected during this survey agreed very well with the exposure rates inferred from previous aerial surveys.« less

  2. Corporatized Radiology: From Down Under to Over Here?

    PubMed

    McGrath, Anika; Maximin, Suresh; Green, Douglas

    2016-01-01

    In this article, we reflect on the current state of corporatized radiology, forces driving consolidation, and alternatives to corporatization that allow radiologists to maintain their autonomy while providing the highest level of care to their medical communities. Copyright © 2015 Mosby, Inc. All rights reserved.

  3. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.

  4. Definition of Local Diagnostic Reference Levels in a Radiology Department Using a Dose Tracking Software.

    PubMed

    Ghetti, C; Ortenzia, O; Palleri, F; Sireus, M

    2017-06-01

    Dose optimization in radiological examinations is a mandatory issue: in this study local Diagnostic Reference Levels (lDRLs) for Clinical Mammography (MG), Computed Tomography (CT) and Interventional Cardiac Procedures (ICP) performed in our Radiology Department were established. Using a dose tracking software, we have collected Average Glandular Dose (AGD) for two clinical mammographic units; CTDIvol, Size-Specific Dose Estimate (SSDE), Dose Length Product (DLP) and total DLP (DLPtot) for five CT scanners; Fluoro Time, Fluoro Dose Area Product (DAP) and total DAP (DAPtot) for two angiographic systems. Data have been compared with Italian Regulation and with the recent literature. The 75th percentiles of the different dosimetric indices have been calculated. Automated methods of radiation dose data collection allow a fast and detailed analysis of a great amount of data and an easy determination of lDRLs for different radiological procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Professional profile of radiologic technology educators.

    PubMed

    Legg, Jeffrey S; Pollard, Debra K; Fauber, Terri L

    2005-01-01

    Full-time radiologic technology educators (n = 565) were surveyed to determine their demographic characteristics and professional profile. Overall, the majority of radiologic technology educators surveyed were women between the ages of 40 and 59, had a bachelor's or master's degree, were certified in radiography and reported annual incomes from 40,001 dollars to 60,000 dollars. Most educators spent between 1 hour and 8 hours per week on classroom instruction/laboratory and in the clinical setting. Additionally, hospital or community college programs employed the majority of educators. Demographic characteristics of radiologic technology educators varied according to the type of institution in which they were employed and by education level. Study findings show a potential loss of qualified educators in the near future and the need for increased efforts to prepare and recruit radiologic technologists into the education career path.

  6. Benign Papillomas Without Atypia Diagnosed on Core Needle Biopsy: Experience From a Single Institution and Proposed Criteria for Excision

    PubMed Central

    Nayak, Anupma; Carkaci, Selin; Gilcrease, Michael Z.; Liu, Ping; Middleton, Lavinia P.; Bassett, Roland L.; Zhang, Jinxia; Zhang, Hong; Coyne, Robin L.; Bevers, Therese B.; Sneige, Nour; Huo, Lei

    2015-01-01

    The management of benign papilloma (BP) without atypia identified on breast core needle biopsy (CNB) is controversial. We describe the clinicopathologic features of 80 patients with such lesions in our institution, with an upgrade rate to malignancy of 3.8%. A multidisciplinary approach to select patients for surgical excision is recommended. Background The management of benign papilloma (BP) without atypia identified on breast core needle biopsy (CNB) is controversial. In this study, we determined the upgrade rate to malignancy for BPs without atypia diagnosed on CNB and whether there are factors associated with upgrade. Methods Through our pathology database search, we studied 80 BPs without atypia identified on CNB from 80 patients from 1997 to 2010, including 30 lesions that had undergone excision and 50 lesions that had undergone ≥ 2 years of radiologic follow-up. Associations between surgery or upgrade to malignancy and clinical, radiologic, and pathologic features were analyzed. Results Mass lesions, lesions sampled by ultrasound-guided CNB, and palpable lesions were associated with surgical excision. All 3 upgraded cases were mass lesions sampled by ultrasound-guided CNB. None of the lesions with radiologic follow-up only were upgraded to malignancy. The overall upgrade rate was 3.8%. None of the clinical, radiologic, or histologic features were predictive of upgrade. Conclusion Because the majority of patients can be safely managed with radiologic surveillance, a selective approach for surgical excision is recommended. Our proposed criteria for excision include pathologic/radiologic discordance or sampling by ultrasound-guided CNB without vacuum assistance when the patient is symptomatic or lesion size is ≥ 1.5 cm. PMID:24119786

  7. The sharing of radiological images by professional mixed martial arts fighters on social media

    PubMed Central

    Joyce, Cormac W; McCarthy, Peter

    2017-01-01

    Background Mixed martial arts is a sport that has recently enjoyed a significant increase in popularity. This rise in popularity has catapulted many of these “cage fighters” into stardom and many regularly use social media to reach out to their fans. An interesting result of this interaction on social media is that athletes are sharing images of their radiological examinations when they sustain an injury. Purpose To review instances where mixed martial arts fighters shared images of their radiological examinations on social media and in what context they were shared. Material and Methods An Internet search was performed using the Google search engine. Search terms included “MMA,” “mixed martial arts,” “injury,” “scan,” “X-ray,” “fracture,” and “break.” Articles which discussed injuries to MMA fighters were examined and those in which the fighter themselves shared a radiological image of their injury on social media were identified. Results During our search, we identified 20 MMA fighters that had shared radiological images of their injuries on social media. There were 15 different types of injury, with a fracture of the mid-shaft of the ulna being the most common. The most popular social media platform was Twitter. The most common imaging modality X-ray (71%). The majority of injuries were sustained during competition (81%) and 35% of these fights resulted in a win for the fighter. Conclusion Professional mixed martial artists are sharing radiological images of their injuries on social media. This may be in an attempt to connect with fans and raise their profile among other fighters. PMID:28717518

  8. Strategies in Interventional Radiology: Formation of an Interdisciplinary Center of Vascular Anomalies - Chances and Challenges for Effective and Efficient Patient Management.

    PubMed

    Sadick, Maliha; Dally, Franz Josef; Schönberg, Stefan O; Stroszczynski, Christian; Wohlgemuth, Walter A

    2017-10-01

    Background  Radiology is an interdisciplinary field dedicated to the diagnosis and treatment of numerous diseases and is involved in the development of multimodal treatment concepts. Method  Interdisciplinary case management, a broad spectrum of diagnostic imaging facilities and dedicated endovascular radiological treatment options are valuable tools that allow radiology to set up an interdisciplinary center for vascular anomalies. Results  Image-based diagnosis combined with endovascular treatment options is an essential tool for the treatment of patients with highly complex vascular diseases. These vascular anomalies can affect numerous parts of the body so that a multidisciplinary treatment approach is required for optimal patient care. Conclusion  This paper discusses the possibilities and challenges regarding effective and efficient patient management in connection with the formation of an interdisciplinary center for vascular anomalies with strengthening of the clinical role of radiologists. Key points   · Vascular anomalies, which include vascular tumors and malformations, are complex to diagnose and treat.. · There are far more patients with vascular anomalies requiring therapy than interdisciplinary centers for vascular anomalies - there is currently a shortage of dedicated interdisciplinary centers for vascular anomalies in Germany that can provide dedicated care for affected patients.. · Radiology includes a broad spectrum of diagnostic and minimally invasive therapeutic tools which allow the formation of an interdisciplinary center for vascular anomalies for effective, efficient and comprehensive patient management.. Citation Format · Sadick M, Dally FJ, Schönberg SO et al. Strategies in Interventional Radiology: Formation of an Interdisciplinary Center of Vascular Anomalies - Chances and Challenges for Effective and Efficient Patient Management. Fortschr Röntgenstr 2017; 189: 957 - 966. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Electricity restructuring and nuclear power renewal in Ontario: A glossary and list of acronyms. Backgrounder Number 13

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yeager, L.; Mills, C.

    1997-12-31

    This glossary is arranged in alphabetical order in three sections: Electrical planning and generation terms; electrical power and nuclear generation acronyms and abbreviations; and radiological quantities and units. The glossary provides a handy reference for those interested in policy issues involving the electricity sector.

  10. 76 FR 30204 - Exelon Nuclear, Dresden Nuclear Power Station, Unit 1; Exemption From Certain Security Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-24

    ... Power Station, Unit 1; Exemption From Certain Security Requirements 1.0 Background Exelon Nuclear is the licensee and holder of Facility Operating License No. DPR-2 issued for Dresden Nuclear Power Station (DNPS... protection of licensed activities in nuclear power reactors against radiological sabotage,'' paragraph (b)(1...

  11. 75 FR 55803 - Neurological Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001... Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, MD 20993, or FDA... the treatment of depression. FDA intends to make background material available to the public no later...

  12. 78 FR 68459 - Medical Device Development Tools; Draft Guidance for Industry, Tool Developers, and Food and Drug...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-14

    ... Radiological Health (CDRH) for qualification of medical device development tools (MDDT) for use in device.... Background The draft guidance describes the framework and process for the voluntary CDRH qualification of... science; and (4) more quickly and more clearly communicate with CDRH stakeholders about important advances...

  13. Spending an Evening in the Dark: The Radiology Medical Student Call Experience.

    PubMed

    Monks, Dennis; Pagano, Brian; Hartman, Matthew

    The level of independent decision-making required of a radiology resident, as well as the acuity of studies populating the worklist, differ between the normal workday and a call shift. However, unlike clerkships where call is standard, medical students in radiology typically only have half of the true resident experience. To expose our rotating medical students to what a future career in radiology might actually look like, we implemented a required call shift as part of our medical student curriculum. All rotating third- and fourth-year medical students were assigned a single 3-hour short call shift alongside a radiology resident during the final week of their rotation. Following this shift, students answered questions via anonymous online survey regarding their perceptions of radiology (primary end point) as well as workload and role of radiology in the clinical care of patients (secondary end points). Following medical student call, 63% of students reported a more positive view of radiology as a career. Additionally, 57% felt that radiology residents work as much or more than other specialties while one call, and several students identified communication issues regarding indications or appropriateness of studies. While we hope that this overwhelmingly positive experience will draw more students into radiology as a career, we also believe that many participating medical students will benefit from a greater understanding of what a radiologist׳s job entails, as well as how this may be affected by communication issues or increased utilization of imaging. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. The Importance of Human-Computer Interaction in Radiology E-learning.

    PubMed

    den Harder, Annemarie M; Frijlingh, Marissa; Ravesloot, Cécile J; Oosterbaan, Anne E; van der Gijp, Anouk

    2016-04-01

    With the development of cross-sectional imaging techniques and transformation to digital reading of radiological imaging, e-learning might be a promising tool in undergraduate radiology education. In this systematic review of the literature, we evaluate the emergence of image interaction possibilities in radiology e-learning programs and evidence for effects of radiology e-learning on learning outcomes and perspectives of medical students and teachers. A systematic search in PubMed, EMBASE, Cochrane, ERIC, and PsycInfo was performed. Articles were screened by two authors and included when they concerned the evaluation of radiological e-learning tools for undergraduate medical students. Nineteen articles were included. Seven studies evaluated e-learning programs with image interaction possibilities. Students perceived e-learning with image interaction possibilities to be a useful addition to learning with hard copy images and to be effective for learning 3D anatomy. Both e-learning programs with and without image interaction possibilities were found to improve radiological knowledge and skills. In general, students found e-learning programs easy to use, rated image quality high, and found the difficulty level of the courses appropriate. Furthermore, they felt that their knowledge and understanding of radiology improved by using e-learning. In conclusion, the addition of radiology e-learning in undergraduate medical education can improve radiological knowledge and image interpretation skills. Differences between the effect of e-learning with and without image interpretation possibilities on learning outcomes are unknown and should be subject to future research.

  15. Single-centre experience of radiation exposure in acute surgical patients: assessment of therapeutic impact and future recommendations.

    PubMed

    Fitzmaurice, Gerard J; Brown, Robin; Cranley, Brian; Conlon, Enda F; Todd, R Alan J; O'Donnell, Mark E

    2010-09-01

    Radiological investigations have become a key adjunct in patient management and consequently radiation exposure to patients is increasing. The study objectives were to examine the use of radiological investigations in the management of acute surgical patients and to assess whether a guideline-based radiation exposure risk/benefit analysis can aid in the choice of radiological investigation used. A prospective observational study was completed over a 12-week period from April to July 2008 for all acute surgical admissions. Data recorded included demographics, clinical presentation, differential diagnosis, investigations, surgical interventions, and final clinical outcome. The use of radiological investigative modalities as an adjunct to clinical assessment was then evaluated against The Royal College of Radiologists (RCR) guidelines. A total of 380 acute surgical admissions (M = 174, F = 185, children = 21) were assessed during the study period. Seven hundred thirty-four radiological investigations were performed with a mean of 1.93 investigations per patient. Based on the RCR guidelines, 680 (92.6%) radiological investigations were warranted and included 142 CT scans (19.3%), 129 chest X-rays (17.6%), and 85 abdominal X-rays (11.6%). Clinically, radiological imaging complemented surgical management in 326 patients (85.8%) and the management plan remained unchanged for the remaining 54 patients (14.2%). This accounted for an average radiation dose of 4.18 millisievert (mSv) per patient or 626 days of background radiation exposure. CT imaging was responsible for the majority of the radiation exposure, with a total of 1310 mSv (82.6%) of the total radiation exposure being attributed to CT imaging in 20.8% of acute admissions. Subgroup analysis demonstrated that 92.8% of the CT scans performed were appropriate. Radiation exposure was generally low for the majority of acute surgical admissions. However, it is recommended that CT imaging requests be evaluated carefully, particularly for patients with clinically confirmed pathologies and in younger women.

  16. Academic tenure in radiologic technology--revisited.

    PubMed

    Legg, Jeffrey S

    2007-01-01

    Academic tenure is important to most educators, including those in the radiologic sciences; however, many factors can influence an educator's ability to attain tenure. This article empirically examines the concept of tenure among radiologic science educators using data from a national survey of registered radiologic technology educators. Greater proportions of tenured and tenure-eligible faculty held higher academic rank, had higher levels of education and were employed by 2- and 4-year colleges or universities compared with nontenure-track faculty. Also, tenured R.T. educators tended to be older than tenure-eligible and nontenure-track faculty. R.T. educators are a diverse group, and attention should focus on the individual needs of educators in a variety of professional settings.

  17. Computer aided system for segmentation and visualization of microcalcifications in digital mammograms.

    PubMed

    Reljin, Branimir; Milosević, Zorica; Stojić, Tomislav; Reljin, Irini

    2009-01-01

    Two methods for segmentation and visualization of microcalcifications in digital or digitized mammograms are described. First method is based on modern mathematical morphology, while the second one uses the multifractal approach. In the first method, by using an appropriate combination of some morphological operations, high local contrast enhancement, followed by significant suppression of background tissue, irrespective of its radiology density, is obtained. By iterative procedure, this method highly emphasizes only small bright details, possible microcalcifications. In a multifractal approach, from initial mammogram image, a corresponding multifractal "images" are created, from which a radiologist has a freedom to change the level of segmentation. An appropriate user friendly computer aided visualization (CAV) system with embedded two methods is realized. The interactive approach enables the physician to control the level and the quality of segmentation. Suggested methods were tested through mammograms from MIAS database as a gold standard, and from clinical praxis, using digitized films and digital images from full field digital mammograph.

  18. Radiochemical Analyses of the Filter Cake, Granular Activated Carbon, and Treated Ground Water from the DTSC Stringfellow Superfund Site Pretreatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Esser, B K; McConachie, W; Fischer, R

    2005-09-16

    The Department of Toxic Substance Control (DTSC) requested that Lawrence Livermore National Laboratory (LLNL) evaluate the treatment process currently employed at the Department's Stringfellow Superfund Site Pretreatment Plant (PTP) site to determine if wastes originating from the site were properly managed with regards to their radioactivity. In order to evaluate the current management strategy, LLNL suggested that DTSC characterize the effluents from the waste treatment system for radionuclide content. A sampling plan was developed; samples were collected and analyzed for radioactive constituents. Following is brief summary of those results and what implications for waste characterization may be made. (1) Themore » sampling and analysis provides strong evidence that the radionuclides present are Naturally Occurring Radioactive Material (NORM). (2) The greatest source of radioactivity in the samples was naturally occurring uranium. The sample results indicate that the uranium concentration in the filter cake is higher than the Granular Activated Carbon (GAC) samples. (11 -14 and 2-6 ppm respectively). (3) No radiologic background for geologic materials has been established for the Stringfellow site, and comprehensive testing of the process stream has not been conducted. Without site-specific testing of geologic materials and waste process streams, it is not possible to conclude if filter cake and spent GAC samples contain radioactivity concentrated above natural background levels, or if radionuclides are being concentrated by the waste treatment process. Recommendation: The regulation of Technologically Enhanced, Naturally Occurring Radioactive Materials (T-NORM) is complex. Since the results of this study do not conclusively demonstrate that natural radioactive materials have not been concentrated by the treatment process it is recommended that the DTSC consult with the Department of Health Services (DHS) Radiological Health Branch to determine if any further action is warranted. If it were deemed desirable to establish a background for the Stringfellow setting LLNL would recommend that additional samples be taken and analyzed by LLNL using the same methods presented in this report.« less

  19. National low-level waste management program radionuclide report series, Volume 15: Uranium-238

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, J.P.

    1995-09-01

    This report, Volume 15 of the National Low-Level Waste Management Program Radionuclide Report Series, discusses the radiological and chemical characteristics of uranium-238 ({sup 238}U). The purpose of the National Low-Level Waste Management Program Radionuclide Report Series is to provide information to state representatives and developers of low-level radioactive waste disposal facilities about the radiological, chemical, and physical characteristics of selected radionuclides and their behavior in the waste disposal facility environment. This report also includes discussions about waste types and forms in which {sup 238}U can be found, and {sup 238}U behavior in the environment and in the human body.

  20. The effect of radiology services outsourcing on patients’ satisfaction in Tehran city hospitals

    PubMed Central

    Mousavi, H; Khodamoradi, F; Rostami Zarinabadi, CH; Mozafar Saadati, H; Mohammadi, M; Mahboubi, M; Mousavi, N

    2015-01-01

    Background: To have a developed society we should have healthy, active, and happy individuals and present that extended healthcare services perform an essential function in increasing the society’s health level. Health in a society includes the society’s, and people comfort with the condition and an assuring the situation that they can live healthily. Also, considering the self-governing plan of hospitals from 1995, the hospital authorities should choose a method of presenting services, and, the hospital is ready to present those activities during its own activities from an economic viewpoint. The current study was done while trying to discover the effect of the Outsourcing of the Radiology Unit on the patients’ satisfaction in hospitals of Tehran. Method: The present research was done in a case-evidence and sectional study. Considering the weight of a month’s references to the Radiology Unit, which included around 1200 individuals, the volume of samples for measuring the frequency of the patients’ satisfaction with the means of Morgan table was similar to 291 individuals. To decrease the error percentage in each hospital we questioned 300 individuals. (n+10) were questioned and the gathered information were examined by what means SPSS application variant 21 and were then studied by climagraph – Smirnoph, Du Whitman – Vitney K tests. Findings: the mean of the patients’ satisfaction of turned over and non-turned over Radiology Unit services were 41.46 and 45, respectively (from the maximum score of 60). A meaningful variation was seen among the patients' Satisfaction in the two hospitals from the analytical viewpoint (p-value<0.001) and there was also a significant difference between the patients’ waiting time (p-value<0.001). The research’s findings showed that the outsourcing has a negative influence on the patients’ satisfaction and the duration of their waiting time. Conclusion: Many times, managers do the outsourcing without considering individual and organizational dimensions and characteristics by just justifying it based on decreasing the expenses. Therefore, it is essential for authorities to consider not only the economic characters but also the individual and human aspects while setting the outsourcing contracts and arrangements. PMID:28316662

  1. Work plan for the radiological survey for the David Witherspoon, Incorporated, Landfill-1630 site, Knoxville, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-07-01

    This work plan establishes the methods and requirements for performing a radiological survey at the David Witherspoon, Incorporated, Landfill-1630 Site, Knoxville, Tennessee (DWI 1630 Site) in accordance with requirements under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The radiological survey will identify the radiological contamination level of the equipment and debris stored at the DWI 1630 Site. The data generated from the survey activities will support the decisions for characterization of the equipment/debris and aid in subsequent disposition and waste handling. The survey activities to be performed under this work plan include an equipment radiological survey,more » a walkover survey, and an immunoassay testing for polychlorinated biphenyls (PCBs). This work plan includes a quality assurance (QA)/quality control (QC) project plan, a health and safety (H&S) plan, and a waste management plan.« less

  2. CT Lung Cancer Screening Program Development: Part 2.

    PubMed

    Yates, Teri

    2015-01-01

    Radiology administrators must use innovative strategies around clinical collaboration and marketing to ensure that patients access the service in sufficient numbers. Radiology Associates of South Florida in collaboration with Baptist Health South Florida have developed a successful lung cancer screening program. The biggest factors in their success have been the affordability of their service and the quality of the program. Like mammography, lung cancer screening programs serve as an entry point to other services that generate revenue for the hospital. Patients may require further evaluation in the form of more imaging or surgical services for biopsy. Part 1 provided background and laid out fundamentals for starting a program. Part 2 focuses on building patient volume, marketing, and issues related to patient management after the screen is performed.

  3. [A radiological case collection with interactive character as a new element in the education of medical students].

    PubMed

    Heye, T; Kurz, P; Eiers, M; Kauffmann, G W; Schipp, A

    2008-04-01

    Evaluation of an interactive, multimedia case-based learning platform for the radiological education of medical students. An interactive electronic learning platform for the education of medical students was built in HTML format independent of the operating system in the context of the Heidelberg Curriculum Medicinale (HeiCuMed). A case collection of 30 common and authentic clinical cases is used as the central theme and clinical background. The user has to work on each case by making decisions regarding a selection of diagnostic modalities and by analyzing the chosen studies. After a reasonable selection and sequence of diagnostic radiological modalities and their interpretation, a diagnosis has to be made. An extensive collection of normal findings for any modality is available for the user as a reference in correlation with the pathology at anytime within each case. The case collection consists of 2053 files with 1109 Internet pages (HTML) and 869 image files (.jpeg) with approximately 10 000 crosslinks (links). The case collection was evaluated by a questionnaire (scale 1 - 5) at the end of the radiological student course. The development of the results of the radiological course exam was analyzed to investigate any effect on the learning performance after the case collection was introduced. 97.6 % of the course participants would use the case collection beyond the radiological student course to learn radiology in their medical studies. The handling of the case collection was rated excellent in 36.9 %, good in 54.6 %, satisfactory in 8 % and unsatisfactory in 0.4 %. 41 % felt that the case collection was overall excellent, 49.2 % good, 7.8 % satisfactory, 1.6 % unsatisfactory and 0.4 % poor. A positive trend in the development of the results in the radiological course exam with less variance after the introduction of the case collection was found but failed statistical significance. A platform-independent, interactive, multimedia learning platform with authentic clinical cases and multiple choice elements for the user is the ideal method for supporting and expanding medical education in radiology. The usefulness and the reasonable exertion of diagnostic modalities are conveyed in a practical context as teaching goals. The high acceptance among students is based on the interactivity and use of multimedia.

  4. White Paper: Radiological Curriculum for Undergraduate Medical Education in Germany.

    PubMed

    Ertl-Wagner, B; Barkhausen, J; Mahnken, A H; Mentzel, H J; Uder, M; Weidemann, J; Stumpp, P

    2016-11-01

    Purpose: Radiology represents a highly relevant part of undergraduate medical education from preclinical studies to subinternship training. It is therefore important to establish a content base for teaching radiology in German Medical Faculties. Materials and Methods: The German Society of Radiology (DRG) developed a model curriculum for radiological teaching at German medical universities, which is presented in this article. There is also a European model curriculum for undergraduate teaching (U-level curriculum of the European Society of Radiology). In a modular concept, the students shall learn important radiological core principles in the realms of knowledge, skills and competences as well as core scientific competences in the imaging sciences. Results: The curriculum is divided into two modules. Module 1 includes principles of radiation biology, radiation protection and imaging technology, imaging anatomy as well as the risks and side effects of radiological methods, procedures and contrast media. This module is modality-oriented. Module 2 comprises radiological diagnostic decision-making and imaging-based interventional techniques for various disease entities. This module is organ system-oriented. Conclusion: The curriculum is meant as a living document to be amended and revised at regular intervals. The curriculum can be used as a basis for individual curricular development at German Medical Faculties. It can be integrated into traditional or reformed medical teaching curricula. Key Points: • Radiology is an integral and important part of medical education.• The German Society of Radiology (DRG) developed a model curriculum for teaching radiology at German Medical Faculties to help students develop the ability to make medical decisions based on scientific knowledge and act accordingly.• This curriculum can be used for individual curricular development at medical departments. It is divided into two modules with several chapters. Citation Format: • Ertl-Wagner B, Barkhausen J, Mahnken AH et al. White Paper: Radiological Curriculum for Undergraduate Medical Education in Germany. Fortschr Röntgenstr 2016; 188: 1017 - 1023. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Surface Cleaning Techniques: Ultra-Trace ICP-MS Sample Preparation and Assay of HDPE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Overman, Nicole R.; Hoppe, Eric W.; Addleman, Raymond S.

    2013-06-01

    The world’s most sensitive radiation detection and assay systems depend upon ultra-low background (ULB) materials to reduce unwanted radiological backgrounds. Herein, we evaluate methods to clean HDPE, a material of interest to ULB systems and the means to provide rapid assay of surface and bulk contamination. ULB level material and ultra-trace level detection of actinide elements is difficult to attain, due to the introduction of contamination from sample preparation equipment such as pipette tips, sample vials, forceps, etc. and airborne particulate. To date, literature available on the cleaning of such polymeric materials and equipment for ULB applications and ultra-trace analysesmore » is limited. For these reasons, a study has been performed to identify an effective way to remove surface contamination from polymers in an effort to provide improved instrumental detection limits. Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) was utilized to assess the effectiveness of a variety of leachate solutions for removal of inorganic uranium and thorium surface contamination from polymers, specifically high density polyethylene (HDPE). HDPE leaching procedures were tested to optimize contaminant removal of thorium and uranium. Calibration curves for thorium and uranium ranged from 15 ppq (fg/mL) to 1 ppt (pg/mL). Detection limits were calculated at 6 ppq for uranium and 7 ppq for thorium. Results showed the most effective leaching reagent to be clean 6 M nitric acid for 72 hour exposures. Contamination levels for uranium and thorium found in the leachate solutions were significant for ultralow level radiation detection applications.« less

  6. Radiological factors affecting post-operative global coronal balance in Lenke 5 C scoliosis

    PubMed Central

    Suresh, Subramani; Aiyer, Siddharth N.; Kanna, Rishi; Rajasekaran, Shanmuganathan

    2017-01-01

    Background Lenke 5 C curves are frequently associated with clinically and radiological coronal imbalance. Appropriate selection of proximal and distal levels of fusion is essential to ensure good coronal balance (CB). We aimed to evaluate radiological factors associated with (I) global CB in the early post-operative period; (II) late decompensation of CB; and (III) favourable spontaneous correction of CB on long term follow up. Methods Twenty-three Lenke type 5C scoliosis cases treated with selective posterior lumbar instrumentation were retrospectively evaluated. Pre-operative, early post-operative and late post-operative (>2 years) whole length radiographs were analysed. Cobb’s angle, lumbar lordosis, coronal imbalance, lower instrumented vertebra (LIV) tilt and translation and upper instrumented vertebra (UIV) tilt and translation were measured. The proximal and distal fusion levels were noted and correlated with post-operative CB. Results There were 21 females and 2 males with a mean follow up of 36 months. The mean pre-operative cobb angle was 55°±13.26°, which corrected to 14.7°±8.84° and was maintained on follow up. Eight patients had early post-operative coronal imbalance with spontaneous resolution seen in six cases on long term follow-up. At final follow-up, four cases had coronal imbalance (persistent imbalance since early post-operative period =2; late decompensation =2). In cases with early imbalance 5/8 cases had a pre-operative LIV tilt of ≥25°. All four patients with coronal imbalance at final follow-up had pre-operative LIV tilt ≥25°. Radiographic parameters which correlated with post-operative coronal imbalance were pre-operative LIV tilt (r=0.64, P=0.001), pre-operative LIV translation (r=0.696, P<0.001), pre-operative UIV translation (r=0.44, P=0.030), post-operative LIV tilt (r=0.804, P<0.001), and post-operative UIV tilt (r=0.62, P=0.001). Conclusions In Lenke 5C scoliosis, a pre-operative LIV tilt ≥25° significantly correlates with post-operative global coronal imbalance. Increasing UIV tilt may be a factor that accounts for improvement of CB in late follow-up period. PMID:29354729

  7. Inpatient Complexity in Radiology-a Practical Application of the Case Mix Index Metric.

    PubMed

    Mabotuwana, Thusitha; Hall, Christopher S; Flacke, Sebastian; Thomas, Shiby; Wald, Christoph

    2017-06-01

    With ongoing healthcare payment reforms in the USA, radiology is moving from its current state of a revenue generating department to a new reality of a cost-center. Under bundled payment methods, radiology does not get reimbursed for each and every inpatient procedure, but rather, the hospital gets reimbursed for the entire hospital stay under an applicable diagnosis-related group code. The hospital case mix index (CMI) metric, as defined by the Centers for Medicare and Medicaid Services, has a significant impact on how much hospitals get reimbursed for an inpatient stay. Oftentimes, patients with the highest disease acuity are treated in tertiary care radiology departments. Therefore, the average hospital CMI based on the entire inpatient population may not be adequate to determine department-level resource utilization, such as the number of technologists and nurses, as case length and staffing intensity gets quite high for sicker patients. In this study, we determine CMI for the overall radiology department in a tertiary care setting based on inpatients undergoing radiology procedures. Between April and September 2015, CMI for radiology was 1.93. With an average of 2.81, interventional neuroradiology had the highest CMI out of the ten radiology sections. CMI was consistently higher across seven of the radiology sections than the average hospital CMI of 1.81. Our results suggest that inpatients undergoing radiology procedures were on average more complex in this hospital setting during the time period considered. This finding is relevant for accurate calculation of labor analytics and other predictive resource utilization tools.

  8. Educational treasures in radiology: a free online program for Radiology Boards preparation.

    PubMed

    Talanow, Roland

    2011-01-01

    An objective tool is desired, which optimally prepares for Radiology boards examination. Such program should prepare examinees with pertinent radiological contents and simulations as expected in the real examination. Many countries require written boards examinations for Radiology certification eligibility. No objective measure exists to tell if the examinee is ready to pass the exam or not. Time pressure and computer environment might be unfamiliar to examinees. Traditional preparation lectures don't simulate the "real" Radiology exam because they don't provide the special environment with multiple choice questions and timing. This online program consists of 4 parts. The entry section allows to create questions with additional fields for comprehensive information. Sections include Pediatrics/Mammography/GI/IR/Nucs/Thoracic/Musculoskeletal/GU/Neuro/Ultrasound/Cardiac/OB/GYN and Miscellaneous. Experienced radiologists and educators evaluate and release/delete these entries in the administrator section. In the exam section users can create (un)timed customized exams for individual needs and learning pace. Exams can either include all sections or only specific sections to gear learning towards areas with weaker performance. Comprehensive statistics unveil the user's strengths and weaknesses to help focussing on "weak" areas. In the search section a comprehensive search and review can be performed by searching the entire database for keywords/topics or only searching within specific sections. www.RadiologyBoards.org is a new working concept of Radiology boards preparation to detect and improve the examinee's weaknesses and finally to increase the examinee's confidence level for the final exam. It is beneficial for Radiology residents and also board certified radiologists to refresh/maintain radiological knowledge.

  9. Nuclear Warfare Water Contamination.

    DTIC Science & Technology

    1982-05-01

    obscured the important relationship between radionuclide ground concentrations and fallout dose rate contours by focusing too much attention on the...19 ) Radiological water contamination by nonpoint sources has received little, if any, attention in the current literature on the environmental... attention . Nevertheless, the environmental contamination of water supplies by fallout has been noted as a source of background radiation (20 ) and a possible

  10. 76 FR 72007 - ZionSolutions, LLC; Zion Nuclear Power Station, Units 1 and 2; Exemption From Certain Security...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-21

    ...; Zion Nuclear Power Station, Units 1 and 2; Exemption From Certain Security Requirements 1.0 Background Zion Nuclear Power Station (ZNPS or Zion), Unit 1, is a Westinghouse 3250 MWt Pressurized Water Reactor... activities in nuclear power reactors against radiological sabotage,'' paragraph (b)(1) states, ``The licensee...

  11. Strategy development for anticipating and handling a disruptive technology.

    PubMed

    Chan, Stephen

    2006-10-01

    The profession of radiology has greatly benefited from the introduction of new imaging technologies throughout its history. Therefore, it would seem reasonable for radiologists to believe that the emergence of a new imaging technology can generally be foreseen with sufficient advance notice to allow the appropriate levels of time, effort, and money to be devoted toward incorporating it into radiology practice. However, in his seminal work, Christiansen characterized a new form of technologic innovation, known as "disruptive technology," whose emergence often heralds the replacement of market leaders in an industry by competitors who are quicker in adopting and deploying the new technology. This article briefly describes the phenomenon of disruptive technology and addresses the challenges that organizations face in dealing with disruptive technology. The article raises 4 questions about the future of radiology: (1) Are health care and radiology vulnerable to disruptive technology? (2) What kinds of change may be in store for the radiology profession? (3) Can the radiology profession prepare itself to recognize and respond to a disruptive innovation among a group of new imaging technologies? and (4) How should a radiology organization decide whether to invest significant resources in a potentially disruptive technology? This article addresses these questions by reviewing key insights from leading "gurus" in the fields of competitive strategy and technology management and applying them to radiology. This illustrates how and why (despite past successes) the radiology profession may still have a blind spot in recognizing and handling disruptive technologies.

  12. Radiation Protection Knowledge, Attitude, and Practice (KAP) in Interventional Radiology

    PubMed Central

    Shabani, Fatemeh; Hasanzadeh, Hadi; Emadi, Alireza; Mirmohammadkhani, Majid; Bitarafan-Rajabi, Ahmad; Abedelahi, Ali; Bokharaeian, Mitra; Masoumi, Hamed; Seifi, Danial; Khani, Tahereh; Sanchooli, Mohamad; Moshfegh, Shima; Ziari, Abbas

    2018-01-01

    Objectives Due to increasing cardiac disease and its mortality rate, the frequency of cardiac imaging has grown and, as a result, interventional cardiologists potentially receive high radiation doses in cardiac examinations. This study aimed to assess the knowledge, attitude, and practice (KAP) level of radiation protection (RP) among interventional radiology staff in Iranian health care centers across the country. Methods We used a validated questionnaire survey consisting of 30 multiple-choice questions to perform a cross-sectional study. Participants were healthcare personnel working professionally with radiation at different levels (i.e., secretary, radiology technologists, nurse, and physician). The questionnaire was divided into three sections to assess KAP regarding RP. Results Significant differences exist in RP KAP mean scores based on educational age (p < 0.050). There was no significant difference in RP KAP mean scores when looking at sex, practice age, and hospital type (p > 0.050). We found a significant difference between RP KAP mean scores and different regions (p < 0.050). Conclusions Educational and practice age, sex, type of hospital, and geographical region affect he KAP of interventional radiology staff regarding RP. Since many of the subjective radiation harms for both medical team and patients, this can be easily controlled and prevented; a checkup for personnel of interventional radiology departments, considering samples from different parts of the country with different levels of education, continuous training, and practical courses may help map the status of KAP. The results of this study may also help authorized health physics officers design strategic plans to enhance the quality of such services in radiation departments. PMID:29657683

  13. Radiation Protection Knowledge, Attitude, and Practice (KAP) in Interventional Radiology.

    PubMed

    Shabani, Fatemeh; Hasanzadeh, Hadi; Emadi, Alireza; Mirmohammadkhani, Majid; Bitarafan-Rajabi, Ahmad; Abedelahi, Ali; Bokharaeian, Mitra; Masoumi, Hamed; Seifi, Danial; Khani, Tahereh; Sanchooli, Mohamad; Moshfegh, Shima; Ziari, Abbas

    2018-03-01

    Due to increasing cardiac disease and its mortality rate, the frequency of cardiac imaging has grown and, as a result, interventional cardiologists potentially receive high radiation doses in cardiac examinations. This study aimed to assess the knowledge, attitude, and practice (KAP) level of radiation protection (RP) among interventional radiology staff in Iranian health care centers across the country. We used a validated questionnaire survey consisting of 30 multiple-choice questions to perform a cross-sectional study. Participants were healthcare personnel working professionally with radiation at different levels (i.e., secretary, radiology technologists, nurse, and physician). The questionnaire was divided into three sections to assess KAP regarding RP. Significant differences exist in RP KAP mean scores based on educational age (p < 0.050). There was no significant difference in RP KAP mean scores when looking at sex, practice age, and hospital type (p > 0.050). We found a significant difference between RP KAP mean scores and different regions (p < 0.050). Educational and practice age, sex, type of hospital, and geographical region affect he KAP of interventional radiology staff regarding RP. Since many of the subjective radiation harms for both medical team and patients, this can be easily controlled and prevented; a checkup for personnel of interventional radiology departments, considering samples from different parts of the country with different levels of education, continuous training, and practical courses may help map the status of KAP. The results of this study may also help authorized health physics officers design strategic plans to enhance the quality of such services in radiation departments.

  14. Shades of Grey: An Exploration of the Student Learning Experience in Diagnostic Imaging Education

    ERIC Educational Resources Information Center

    Linaker, Kathleen Linda

    2012-01-01

    Diagnostic radiology education is a specialty within healthcare education and encompasses education at both the undergraduate and resident level. There is little research regarding what constitutes effective radiology education. The broad purpose of this study was to investigate through the student perspective how chiropractic students learned…

  15. Radiological Sciences Discipline Advisory Group Final Report. Kentucky Allied Health Project.

    ERIC Educational Resources Information Center

    Kentucky Council on Public Higher Education, Frankfort.

    Radiological sciences education in Kentucky and articulation within this field are examined, based on the Kentucky Allied Health Project (KAHP), which designed an articulated statewide system to promote entry and exit of personnel at a variety of educational levels. The KAHP model promotes articulation in learning, planning, and resource…

  16. Radiology Technician, 10-5. Military Curriculum Materials for Vocational and Technical Education.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    These five volumes of student materials for a secondary/postsecondary level course in radiology technology comprise one of a number of military-developed curriculum packages selected for adaptation to vocational instruction and curriculum development in a civilian setting. The purpose stated for the course is to provide the theory portion of…

  17. 78 FR 54655 - Center for Devices and Radiological Health: Draft Standard Operating Procedure for Level 1...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-05

    ... Devices and Radiological Health's (CDRH's or the Center's) draft process to clarify and more quickly inform stakeholders when CDRH has changed its expectations relating to, or otherwise has new scientific... scientific information changes CDRH's regulatory thinking, it has been challenging for the Center to...

  18. POOL WATER TREATMENT AND COOLING SYSTEM DESCRIPTION DOCUMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    V. King

    2000-06-19

    The Pool Water Treatment and Cooling System is located in the Waste Handling Building (WHB), and is comprised of various process subsystems designed to support waste handling operations. This system maintains the pool water temperature within an acceptable range, maintains water quality standards that support remote underwater operations and prevent corrosion, detects leakage from the pool liner, provides the capability to remove debris from the pool, controls the pool water level, and helps limit radiological exposure to personnel. The pool structure and liner, pool lighting, and the fuel staging racks in the pool are not within the scope of themore » Pool Water Treatment and Cooling System. Pool water temperature control is accomplished by circulating the pool water through heat exchangers. Adequate circulation and mixing of the pool water is provided to prevent localized thermal hotspots in the pool. Treatment of the pool water is accomplished by a water treatment system that circulates the pool water through filters, and ion exchange units. These water treatment units remove radioactive and non-radioactive particulate and dissolved solids from the water, thereby providing the water clarity needed to conduct waste handling operations. The system also controls pool water chemistry to prevent advanced corrosion of the pool liner, pool components, and fuel assemblies. Removal of radioactivity from the pool water contributes to the project ALARA (as low as is reasonably achievable) goals. A leak detection system is provided to detect and alarm leaks through the pool liner. The pool level control system monitors the water level to ensure that the minimum water level required for adequate radiological shielding is maintained. Through interface with a demineralized water system, adequate makeup is provided to compensate for loss of water inventory through evaporation and waste handling operations. Interface with the Site Radiological Monitoring System provides continuous radiological monitoring of the pool water. The Pool Water Treatment and Cooling System interfaces with the Waste Handling Building System, Site-Generated Radiological Waste Handling System, Site Radiological Monitoring System, Waste Handling Building Electrical System, Site Water System, and the Monitored Geologic Repository Operations Monitoring and Control System.« less

  19. Resources planning for radiological incidents management

    NASA Astrophysics Data System (ADS)

    Hamid, Amy Hamijah binti Ab.; Rozan, Mohd Zaidi Abd; Ibrahim, Roliana; Deris, Safaai; Yunus, Muhd. Noor Muhd.

    2017-01-01

    Disastrous radiation and nuclear meltdown require an intricate scale of emergency health and social care capacity planning framework. In Malaysia, multiple agencies are responsible for implementing radiological and nuclear safety and security. This research project focused on the Radiological Trauma Triage (RTT) System. This system applies patient's classification based on their injury and level of radiation sickness. This classification prioritizes on the diagnostic and treatment of the casualties which include resources estimation of the medical delivery system supply and demand. Also, this system consists of the leading rescue agency organization and disaster coordinator, as well as the technical support and radiological medical response teams. This research implemented and developed the resources planning simulator for radiological incidents management. The objective of the simulator is to assist the authorities in planning their resources while managing the radiological incidents within the Internal Treatment Area (ITA), Reception Area Treatment (RAT) and Hospital Care Treatment (HCT) phases. The majority (75%) of the stakeholders and experts, who had been interviewed, witnessed and accepted that the simulator would be effective to resolve various types of disaster and resources management issues.

  20. Early resident-to-resident physics education in diagnostic radiology.

    PubMed

    Kansagra, Akash P

    2014-01-01

    The revised ABR board certification process has updated the method by which diagnostic radiology residents are evaluated for competency in clinical radiologic physics. In this work, the author reports the successful design and implementation of a resident-taught physics course consisting of 5 weekly, hour-long lectures intended for incoming first-year radiology residents in their first month of training. To the author's knowledge, this is the first description of a course designed to provide a very early framework for ongoing physics education throughout residency without increasing the didactic burden on faculty members. Twenty-six first-year residents spanning 2 academic years took the course and reported subjective improvement in their knowledge (90%) and interest (75%) in imaging physics and a high level of satisfaction with the use of senior residents as physics educators. Based on the success of this course and the minimal resources required for implementation, this work may serve as a blueprint for other radiology residency programs seeking to develop revised physics curricula. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. Bilateral Multifocal Hamartoma of the Chest Wall in an Infant

    PubMed Central

    Yilmaz, Erdem; Erol, Oguz Bulent; Pekcan, Melih; Gundogdu, Gokcen; Bilgic, Bilge; Gun, Feryal; Yekeler, Ensar

    2015-01-01

    Summary Background Hamartoma of the thoracic wall is a rare benign tumor that occurs in infancy and can be mistaken for a malignancy due to its clinical and imaging features. Hamartomas are extrapleural soft tissue lesions that cause rib expansion and destruction and appear on imaging as cystic areas with fluid levels and calcification. They can cause scoliosis, pressure on the neighboring lung parenchyma and mediastinal displacement. While conservative treatment is recommended in asymptomatic cases, growing lesions require surgical excision. Case Report In this report, we present the imaging findings in a 3-month-old infant that presented with a firm swelling in the chest wall and was histopathologically confirmed to have a bilateral multifocal hamartoma. Conclusions Radiological imaging methods are important for accurate diagnosis of this very rare condition that can be confused with a malignancy. PMID:26082822

  2. Patients’ experience of outsourcing and care related to magnetic resonance examinations

    PubMed Central

    Aspelin, Peter; Bergstrand, Lott; Blomqvist, Lennart

    2014-01-01

    Background Outsourcing radiological examinations from public university hospitals affects the patient, who has to attend a different clinic or hospital for the radiological examination. We currently have a limited understanding of how patients view outsourcing and their care related to MR examinations. Aim Aim. To examine the experiences of patients who are sent to private radiology units when their referrals for MR examinations are outsourced from a university hospital, as well as to explore factors which influence patient satisfaction regarding the quality of care related to the MR examination. Methods A group of patients (n = 160) referred for MR examinations and either examined at a university hospital or at an external private unit were interviewed. The interview was designed as a verbal questionnaire. Data were analyzed using Student’s t test, analysis of variance (ANOVA), and Pearson’s correlation. Results Sixty-nine percent of the patients could neither choose nor influence the location at which they were examined. For those who could, aspects that influenced the patient’s choice of radiology department were: short waiting time 79% (127/160), ease of traveling to the radiology department 68% (110/160), and short distance to their home or work 58% (93/160). For 40% (60/160) of the patients, a short time in the waiting room was related to a positive experience of the MR examination. Conclusion Conclusion. If patients were informed about outsourcing and could also choose where to have their examination, key factors contributing to patient satisfaction could be met even when MR examinations are outsourced. PMID:25142133

  3. Interpretation of Brain CT Scans in the Field by Critical Care Physicians in a Mobile Stroke Unit

    PubMed Central

    Zakariassen, Erik; Lindner, Thomas; Nome, Terje; Bache, Kristi G.; Røislien, Jo; Gleditsch, Jostein; Solyga, Volker; Russell, David; Lund, Christian G.

    2017-01-01

    ABSTRACT BACKGROUND AND PURPOSE In acute stroke, thromboembolism or spontaneous hemorrhage abruptly reduces blood flow to a part of the brain. To limit necrosis, rapid radiological identification of the pathological mechanism must be conducted to allow the initiation of targeted treatment. The aim of the Norwegian Acute Stroke Prehospital Project is to determine if anesthesiologists, trained in prehospital critical care, may accurately assess cerebral computed tomography (CT) scans in a mobile stroke unit (MSU). METHODS In this pilot study, 13 anesthesiologists assessed unselected acute stroke patients with a cerebral CT scan in an MSU. The scans were simultaneously available by teleradiology at the receiving hospital and the on‐call radiologist. CT scan interpretation was focused on the radiological diagnosis of acute stroke and contraindications for thrombolysis. The aim of this study was to find inter‐rater agreement between the pre‐ and in‐hospital radiological assessments. A neuroradiologist evaluated all CT scans retrospectively. Statistical analysis of inter‐rater agreement was analyzed with Cohen's kappa. RESULTS Fifty‐one cerebral CT scans from the MSU were included. Inter‐rater agreement between prehospital anesthesiologists and the in‐hospital on‐call radiologists was excellent in finding radiological selection for thrombolysis (kappa .87). Prehospital CT scans were conducted in median 10 minutes (7 and 14 minutes) in the MSU, and median 39 minutes (31 and 48 minutes) before arrival at the receiving hospital. CONCLUSION This pilot study shows that anesthesiologists trained in prehospital critical care may effectively assess cerebral CT scans in an MSU, and determine if there are radiological contraindications for thrombolysis. PMID:28766306

  4. Clinical, Endoscopic, and Radiologic Features of Three Subtypes of Achalasia, Classified Using High-Resolution Manometry

    PubMed Central

    Khan, Mohammed Q.; AlQaraawi, Abdullah; Al-Sohaibani, Fahad; Al-Kahtani, Khalid; Al-Ashgar, Hamad I.

    2015-01-01

    Background/Aims: High-resolution manometry (HRM) has improved the accuracy of manometry in detecting achalasia and determining its subtypes. However, the correlation of achalasia subtypes with clinical, endoscopic, and radiologic findings has not been assessed. We aimed to evaluate and compare the clinical, endoscopic, and fluoroscopy findings associated with three subtypes of achalasia using HRM. Patients and Methods: The retrospective clinical data, HRM, endoscopy, and radiologic findings were obtained from the medical records of untreated achalasia patients. Results: From 2011 to 2013, 374 patients underwent HRM. Fifty-two patients (14%) were diagnosed with achalasia, but only 32 (8.5%) of these patients had not received treatment and were therefore included in this study. The endoscopy results were normal in 28% of the patients, and a barium swallow was inconclusive in 31% of the achalasia patients. Ten patients (31%) were classified as having type I achalasia, 17 (53%) were classified as type II, and 5 (16%) were classified as type III. Among the three subtypes, type I patients were on average the youngest and had the longest history of dysphagia, mildest chest pain, most significant weight loss, and most dilated esophagus with residual food. Chest pain was most common in type III patients, and frequently had normal fluoroscopic and endoscopic results. Conclusion: The clinical, radiologic, and endoscopic findings were not significantly different between patients with type I and type II untreated achalasia. Type III patients had the most severe symptoms and were the most difficult to diagnose based on varied clinical, radiologic, and endoscopic findings. PMID:26021774

  5. A novel tool for user-friendly estimation of natural, diagnostic and professional radiation risk: Radio-Risk software.

    PubMed

    Carpeggiani, Clara; Paterni, Marco; Caramella, Davide; Vano, Eliseo; Semelka, Richard C; Picano, Eugenio

    2012-11-01

    Awareness of radiological risk is low among doctors and patients. An educational/decision tool that considers each patient' s cumulative lifetime radiation exposure would facilitate provider-patient communication. The purpose of this work was to develop user-friendly software for simple estimation and communication of radiological risk to patients and doctors as a part of the SUIT-Heart (Stop Useless Imaging Testing in Heart disease) Project of the Tuscany Region. We developed a novel software program (PC-platform, Windows OS fully downloadable at http://suit-heart.ifc.cnr.it) considering reference dose estimates from American Heart Association Radiological Imaging 2009 guidelines and UK Royal College of Radiology 2007 guidelines. Cancer age and gender-weighted risk were derived from Biological Effects of Ionising Radiation VII Committee, 2006. With simple input functions (demographics, age, gender) the user selects from a predetermined menu variables relating to natural (e.g., airplane flights and geo-tracked background exposure), professional (e.g., cath lab workers) and medical (e.g., CT, cardiac scintigraphy, coronary stenting) sources. The program provides a simple numeric (cumulative effective dose in milliSievert, mSv, and equivalent number of chest X-rays) and graphic (cumulative temporal trends of exposure, cancer cases out of 100 exposed persons) display. A simple software program allows straightforward estimation of cumulative dose (in multiples of chest X-rays) and risk (in extra % lifetime cancer risk), with simple numbers quantifying lifetime extra cancer risk. Pictorial display of radiation risk may be valuable for increasing radiological awareness in cardiologists. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Financial ratios in diagnostic radiology practices: variability and trends.

    PubMed

    Hogan, Christopher; Sunshine, Jonathan H

    2004-03-01

    To evaluate variation in financial ratios for radiology practices nationwide and trends in these ratios and in payments. In 1999, the American College of Radiology surveyed radiology practices by mail. The final response rate was 66%. Weighting was used to make responses representative of all radiology practices in the United States. Self-reported financial ratios (payments, charges, accounts receivable turnover) were analyzed; 449 responses had usable data on these ratios. Comparison with results of a similar 1992 survey and combined analysis with Medicare data on billed charges provided information on trends. All measures of payment collections declined sharply from 1992 to 1999, with the gross collections rate (revenues as percentage of billed charges) decreasing from 71% to 55%. Average payment for a typical radiology service decreased approximately 4% in dollar terms or approximately 19% in inflation-adjusted terms. In 1999, nonmetropolitan practices appeared to fare better than others. Among insurers, Medicaid stood out as a low and slow payer, but neither managed care nor Medicare had a consistent effect on financial ratios. The gross collections rate varied substantially across geographic areas, as did, in an inverse pattern, the level of billed charges. One-quarter of practices had accounts receivable equal to 90 or more days of billings. The opposing geographic pattern of billed charges and gross collection rate suggests that geographic variation in the latter is driven more by variation in billed charges than by variation in payment levels. Radiologists saw a substantial decrease in the real (inflation-adjusted) value of payment per service during the 1990s. The large fraction of practices with accounts receivable of 90 or more days of billings-a level considered potentially imprudent by financial management advisors-suggests that many practices should improve financial management and that state prompt-payment laws have not had a substantial positive effect. Copyright RSNA, 2004

  7. Effects of Hospital Workers' Friendship Networks on Job Stress.

    PubMed

    Shin, Sung Yae; Lee, Sang Gyu

    2016-01-01

    This study attempted to identify the sources of job stress according to job position and investigate how friendship networks affect job stress. Questionnaires based on The Health Professions Stress Inventory (HPSI) developed by Wolfgang experienced by healthcare providers were collected from 420 nurses, doctors and radiological technologists in two general hospitals in Korea by a multistage cluster sampling method. Multiple regression analysis was used to examine the effects of friendship networks on job stress after controlling for other factors. The severity of job stress differed according to level of job demands (p = .006); radiologic technologists experienced the least stress (45.4), nurses experienced moderate stress (52.4), and doctors experienced the most stress (53.6). Those with long-term friendships characterized by strong connections reported lower levels of stress than did those with weak ties to friends among nurses (1.3, p < .05) and radiological technologists (11.4, p < .01). The degree of cohesion among friends had a positive impact on the level of job stress experienced by nurses (8.2, p < .001) and radiological technologists (14.6, p < .1). Doctors who participated in workplace alumni meetings scored higher than those who did not. However, those who participated in alumni meetings outside the workplace showed the opposite tendency, scoring 9.4 (p < .05) lower than those who did not. The resources from their friendship network include both information and instrumental support. As most radiological technologists were male, their instrumental support positively affected their job stress (9.2, p < .05). Life information support was the primary positive contributor to control of nurses' (4.1, p < .05), radiological technologists' (8.0, p < .05) job stress. The strength and density of such friendship networks were related to job stress. Life information support from their friendship network was the primary positive contributor to control of job stress.

  8. Diagnostic reference levels and complexity indices in interventional radiology: a national programme.

    PubMed

    Ruiz-Cruces, R; Vano, E; Carrera-Magariño, F; Moreno-Rodriguez, F; Soler-Cantos, M M; Canis-Lopez, M; Hernández-Armas, J; Diaz-Romero, F J; Rosales-Espizua, F; Fernandez-Soto, J M; Sanchez-Casanueva, R; Martin-Palanca, A; Perez-Martinez, M; Gil-Agudo, A; Zarca-Diaz, M A; Parra-Osorio, V; Muñoz Ruiz-Canela, J J; Moreno-Sanchez, T; Lopez-Medina, A; Moreno-Saiz, C; Galan-Montenegro, P; Gallego-Beuter, J J; Gonzalez-de-Garay, M; Zapata-Jimenez, J C; Pastor-Vega, J M; Cañete, S

    2016-12-01

    To propose national diagnostic reference levels (DRLs) for interventional radiology and to evaluate the impact of the procedural complexity on patient doses. Eight interventional radiology units from Spanish hospitals were involved in this project. The participants agreed to undergo common quality control procedures for X-ray systems. Kerma area product (KAP) was collected from a sample of 1,649 procedures. A consensus document established the criteria to evaluate the complexity of seven types of procedures. DRLs were set as the 3rd quartile of KAP values. The KAP (3rd quartile) in Gy cm 2 for the procedures included in the survey were: lower extremity arteriography (n = 784) 78; renal arteriography (n = 37) 107; transjugular hepatic biopsies (THB) (n = 30) 45; biliary drainage (BD) (n = 314) 30; uterine fibroid embolization (UFE) (n = 56) 214; colon endoprostheses (CE) (n = 31) 169; hepatic chemoembolization (HC) (n = 269) 303; femoropopliteal revascularization (FR) (n = 62) 119; and iliac stent (n = 66) 170. The complexity involved the increases in the following KAP factors from simple to complex procedures: THB x4; BD x13; UFE x3; CE x3; HC x5; FR x5 and IS x4. The evaluation of the procedure complexity in patient doses will allow the proper use of DRLs for the optimization of interventional radiology. • National DRLs for interventional procedures have been proposed given level of complexity • For clinical audits, the level of complexity should be taken into account. • An evaluation of the complexity levels of the procedure should be made.

  9. Mapping intended spinal site of care from the upright to prone position: an interexaminer reliability study

    PubMed Central

    2014-01-01

    Background Upright examination procedures like radiology, thermography, manual muscle testing, and spinal motion palpation may lead to spinal interventions with the patient prone. The reliability and accuracy of mapping upright examination findings to the prone position is unknown. This study had 2 primary goals: (1) investigate how erroneous spine-scapular landmark associations may lead to errors in treating and charting spine levels; and (2) study the interexaminer reliability of a novel method for mapping upright spinal sites to the prone position. Methods Experiment 1 was a thought experiment exploring the consequences of depending on the erroneous landmark association of the inferior scapular tip with the T7 spinous process upright and T6 spinous process prone (relatively recent studies suggest these levels are T8 and T9, respectively). This allowed deduction of targeting and charting errors. In experiment 2, 10 examiners (2 experienced, 8 novice) used an index finger to maintain contact with a mid-thoracic spinous process as each of 2 participants slowly moved from the upright to the prone position. Interexaminer reliability was assessed by computing Intraclass Correlation Coefficient, standard error of the mean, root mean squared error, and the absolute value of the mean difference for each examiner from the 10 examiner mean for each of the 2 participants. Results The thought experiment suggesting that using the (inaccurate) scapular tip landmark rule would result in a 3 level targeting and charting error when radiological findings are mapped to the prone position. Physical upright exam procedures like motion palpation would result in a 2 level targeting error for intervention, and a 3 level error for charting. The reliability experiment showed examiners accurately maintained contact with the same thoracic spinous process as the participant went from upright to prone, ICC (2,1) = 0.83. Conclusions As manual therapists, the authors have emphasized how targeting errors may impact upon manual care of the spine. Practitioners in other fields that need to accurately locate spinal levels, such as acupuncture and anesthesiology, would also be expected to draw important conclusions from these findings. PMID:24904747

  10. Use of Provocative Angiography to Localize Site in Recurrent Gastrointestinal Bleeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, Ciaran, E-mail: ciaranjohnston@yahoo.co.uk; Tuite, David; Pritchard, Ruth

    2007-09-15

    Background. While the source of most cases of lower gastrointestinal bleeding may be diagnosed with modern radiological and endoscopic techniques, approximately 5% of patients remain who have negative endoscopic and radiological investigations.Clinical Problem. These patients require repeated hospital admissions and blood transfusions, and may proceed to exploratory laparotomy and intraoperative endoscopy. The personal and financial costs are significant. Method of Diagnosis and Decision Making. The technique of adding pharmacologic agents (anticoagulants, vasodilators, fibrinolytics) during standard angiographic protocols to induce a prohemorrhagic state is termed provocative angiography. It is best employed when significant bleeding would otherwise necessitate emergency surgery. Treatment. Thismore » practice frequently identifies a bleeding source (reported success rates range from 29 to 80%), which may then be treated at the same session. We report the case of a patient with chronic lower gastrointestinal hemorrhage with consistently negative endoscopic and radiological workup, who had an occult source of bleeding identified only after a provocative angiographic protocol was instituted, and who underwent succeeding therapeutic coil embolization of the bleeding vessel.« less

  11. Report of ICRP Task Group 80: 'radiological protection in geological disposal of long-lived solid radioactive waste'.

    PubMed

    Weiss, W

    2012-01-01

    The report of International Commission on Radiological Protection (ICRP) Task Group 80 entitled 'Radiological protection in geological disposal of long-lived solid radioactive waste' updates and consolidates previous ICRP recommendations related to solid waste disposal (ICRP Publications 46, 77, and 81). The recommendations given in this report apply specifically to geological disposal of long-lived solid radioactive waste. The report explains how the 2007 system of radiological protection, described in ICRP Publication 103, can be applied in the context of the geological disposal of long-lived solid radioactive waste. The report is written as a self-standing document. It describes the different stages in the lifetime of a geological disposal facility, and addresses the application of relevant radiological protection principles for each stage depending on the various exposure situations that can be encountered. In particular, the crucial factor that influences application of the protection system over the different phases in the lifetime of a disposal facility is the level of oversight that is present. The level of oversight affects the capability to reduce or avoid exposures. Three main time frames have to be considered for the purpose of radiological protection: time of direct oversight when the disposal facility is being implemented and active oversight is taking place; time of indirect oversight when the disposal facility is sealed and indirect oversight is being exercised to provide additional assurance on behalf of the population; and time of no oversight when oversight is no longer exercised because memory is lost. Copyright © 2012. Published by Elsevier Ltd.

  12. Findings in 2002 from a help wanted index of job advertisements: is the job-market shortage of diagnostic radiologists easing?

    PubMed

    Saketkhoo, Daniel D; Sunshine, Jonathan H; Covey, Anne M; Forman, Howard P

    2003-08-01

    The goal of this study is to present the most recent data on the diagnostic radiology job market in the United States using a help wanted index of job advertisements. All diagnostic radiology positions advertised in the American Journal of Roentgenology and Radiology from January through December 2002 were coded by practice type, geographic location, and subspecialty. Data were compared with the previously published results from 1991 through 2001. From January through December 2002, 5117 positions were advertised for diagnostic radiologists, representing a 10.4% decrease from 2001. The 12-month rolling average of job advertisements peaked at 488 in February 2002 and dropped to 432 by December 2002, a level not seen since August 2000. In 2002, 42.7% of positions advertised were academic, representing a steady increase from 34.0% in 1999. When comparing the 4-year periods 1999-2002 and 1995-1998, a statistically significant proportional increase was found for positions advertised in the Midwest. Statistically significant relative increases were also observed for the subspecialties of abdominal radiology, mammography, neuroradiology, pediatric radiology, chest radiology, and nuclear medicine. Statistically significant relative decreases were seen in general and vascular and interventional positions. The absolute demand for diagnostic radiologists nationwide appears to have stabilized during 2002, albeit at a level much higher than in previous years, and may be decreasing. A split seems to have appeared in the market between academia and private practice. Current policy should be directed toward increasing the supply of diagnostic radiologists, especially academicians.

  13. Occupational dose in interventional radiology procedures.

    PubMed

    Chida, Koichi; Kaga, Yuji; Haga, Yoshihiro; Kataoka, Nozomi; Kumasaka, Eriko; Meguro, Taiichiro; Zuguchi, Masayuki

    2013-01-01

    Interventional radiology tends to involve long procedures (i.e., long fluoroscopic times). Therefore, radiation protection for interventional radiology staff is an important issue. This study describes the occupational radiation dose for interventional radiology staff, especially nurses, to clarify the present annual dose level for interventional radiology nurses. We compared the annual occupational dose (effective dose and dose equivalent) among interventional radiology staff in a hospital where 6606 catheterization procedures are performed annually. The annual occupational doses of 18 physicians, seven nurses, and eight radiologic technologists were recorded using two monitoring badges, one worn over and one under their lead aprons. The annual mean ± SD effective dose (range) to the physicians, nurses, and radiologic technologists using two badges was 3.00 ± 1.50 (0.84-6.17), 1.34 ± 0.55 (0.70-2.20), and 0.60 ± 0.48 (0.02-1.43) mSv/y, respectively. Similarly, the annual mean ± SD dose equivalent range was 19.84 ± 12.45 (7.0-48.5), 4.73 ± 0.72 (3.9-6.2), and 1.30 ± 1.00 (0.2-2.7) mSv/y, respectively. The mean ± SD effective dose for the physicians was 1.02 ± 0.74 and 3.00 ± 1.50 mSv/y for the one- and two-badge methods, respectively (p < 0.001). Similarly, the mean ± SD effective dose for the nurses (p = 0.186) and radiologic technologists (p = 0.726) tended to be lower using the one-badge method. The annual occupational dose for interventional radiology staff was in the order physicians > nurses > radiologic technologists. The occupational dose determined using one badge under the apron was far lower than the dose obtained with two badges in both physicians and nonphysicians. To evaluate the occupational dose correctly, we recommend use of two monitoring badges to evaluate interventional radiology nurses as well as physicians.

  14. Uranium Mining and Norm in North America-Some Perspectives on Occupational Radiation Exposure.

    PubMed

    Brown, Steven H; Chambers, Douglas B

    2017-07-01

    All soils and rocks contain naturally occurring radioactive materials (NORM). Many ores and raw materials contain relatively elevated levels of natural radionuclides, and processing such materials can further increase the concentrations of naturally occurring radionuclides. In the U.S., these materials are sometimes referred to as technologically-enhanced naturally occurring radioactive materials (TENORM). Examples of NORM minerals include uranium ores, monazite (a source of rare earth minerals), and phosphate rock used to produce phosphate fertilizer. The processing of these materials has the potential to result in above-background radiation exposure to workers. Following a brief review of the sources and potential for worker exposure from NORM in these varied industries, this paper will then present an overview of uranium mining and recovery in North America, including discussion on the mining methods currently being used for both conventional (underground, open pit) and in situ leach (ISL), also referred to as In Situ Recovery (ISR), and the production of NORM materials and wastes associated with these uranium recovery methods. The radiological composition of the NORM products and wastes produced and recent data on radiological exposures received by workers in the North American uranium recovery industry are then described. The paper also identifies the responsible government agencies in the U.S. and Canada assigned the authority to regulate and control occupational exposure from these NORM materials.

  15. Dose estimates for the local inhabitants from 210Po ingestion via dietary sources at a proposed uranium mining site in India.

    PubMed

    Giri, Soma; Jha, V N; Singh, Gurdeep; Tripathi, R M

    2012-07-01

    To study the distribution of (210)Po activity in food in Bagjata in East Singhbhum, India. (210)Po were analyzed in the food samples of plant origin such as cereals, pulses, fruits, vegetables and food of animal origin such fish, chicken, egg, etc., in and around Bagjata uranium mining area as a part of baseline study after acid digestion. The intake and ingestion dose of the radionuclide was estimated. The general range of (210)Po activity in all the dietary components ranged widely from <0.2-36 Bqkg(-1)(fresh). In the food of plant origin, the minimum activity of (210)Po was estimated in vegetables while maximum in pulses. In food of animal origin, the observed minimum activity of (210)Po was in eggs and the maximum observed was in chicken samples. The intake of (210)Po considering all dietary components was found to be 464 Bq.Y(-1) while the ingestion dose was calculated to be 557 μSv.Y(-1), respectively. The estimated doses are reflecting the natural background dose via the route of ingestion, which is much below the 1 mSv limit set in the International Commission on Radiological Protection (ICRP) recommendations. The study confirms that current levels of (210)Po do not pose a significant radiological risk to the local inhabitants.

  16. Telemedicine-based system for quality management and peer review in radiology.

    PubMed

    Morozov, Sergey; Guseva, Ekaterina; Ledikhova, Natalya; Vladzymyrskyy, Anton; Safronov, Dmitry

    2018-06-01

    Quality assurance is the key component of modern radiology. A telemedicine-based quality assurance system helps to overcome the "scoring" approach and makes the quality control more accessible and objective. A concept for quality assurance in radiology is developed. Its realization is a set of strategies, actions, and tools. The latter is based on telemedicine-based peer review of 23,199 computed tomography (CT) and magnetic resonance imaging (MRI) images. The conception of the system for quality management in radiology represents a chain of actions: "discrepancies evaluation - routine support - quality improvement activity - discrepancies evaluation". It is realized by an audit methodology, telemedicine, elearning, and other technologies. After a year of systemic telemedicine-based peer reviews, the authors have estimated that clinically significant discrepancies were detected in 6% of all cases, while clinically insignificant ones were found in 19% of cases. Most often, problems appear in musculoskeletal records; 80% of the examinations have diagnostic or technical imperfections. The presence of routine telemedicine support and personalized elearning allowed improving the diagnostics quality. The level of discrepancies has decreased significantly (p < 0.05). The telemedicine-based peer review system allows improving radiology departments' network effectiveness. • "Scoring" approach to radiologists' performance assessment must be changed. • Telemedicine peer review and personalized elearning significantly decrease the number of discrepancies. • Teleradiology allows linking all primary-level hospitals to a common peer review network.

  17. PearlTrees web-based interface for teaching informatics in the radiology residency

    NASA Astrophysics Data System (ADS)

    Licurse, Mindy Y.; Cook, Tessa S.

    2014-03-01

    Radiology and imaging informatics education have rapidly evolved over the past few decades. With the increasing recognition that future growth and maintenance of radiology practices will rely heavily on radiologists with fundamentally sound informatics skills, the onus falls on radiology residency programs to properly implement and execute an informatics curriculum. In addition, the American Board of Radiology may choose to include even more informatics on the new board examinations. However, the resources available for didactic teaching and guidance most especially at the introductory level are widespread and varied. Given the breadth of informatics, a centralized web-based interface designed to serve as an adjunct to standardized informatics curriculums as well as a stand-alone for other interested audiences is desirable. We present the development of a curriculum using PearlTrees, an existing web-interface based on the concept of a visual interest graph that allows users to collect, organize, and share any URL they find online as well as to upload photos and other documents. For our purpose, the group of "pearls" includes informatics concepts linked by appropriate hierarchal relationships. The curriculum was developed using a combination of our institution's current informatics fellowship curriculum, the Practical Imaging Informatics textbook1 and other useful online resources. After development of the initial interface and curriculum has been publicized, we anticipate that involvement by the informatics community will help promote collaborations and foster mentorships at all career levels.

  18. Occupational Analysis: Hospital Radiologic Technologist. The UCLA Allied Health Professions Project.

    ERIC Educational Resources Information Center

    Reeder, Glenn D.; And Others

    In an effort to meet the growing demand for skilled radiologic technologists and other supportive personnel educated through the associate degree level, a national survey was conducted as part of the UCLA Allied Health Professions Project to determine the tasks performed by personnel in the field and lay the groundwork for development of…

  19. Comparative study of clinical and radiological outcomes of a zero-profile device concerning reduced postoperative Dysphagia after single level anterior cervical discectomy and fusion.

    PubMed

    Son, Doo Kyung; Son, Dong Wuk; Kim, Ho Sang; Sung, Soon Ki; Lee, Sang Weon; Song, Geun Sung

    2014-08-01

    This study analyzed clinical and radiological outcomes of a zero-profile anchored spacer (Zero-P) and conventional cage-plate (CCP) for single level anterior cervical discectomy and fusion (ACDF) to compare the incidence and difference of postoperative dysphagia with both devices. We retrospectively reviewed our experiences of single level ACDF with the CCP and Zero-P. From January 2011 to December 2013, 48 patients who had single level herniated intervertebral disc were operated on using ACDF, with CCP in 27 patients and Zero-P in 21 patients. Patients who received more than double-level ACDF or combined circumferential fusion were excluded. Age, operation time, estimated blood loss (EBL), pre-operative modified Japanese Orthopaedic Association (mJOA) scores, post-operative mJOA scores, achieved mJOA scores and recovery rate of mJOA scores were assessed. Prevertebral soft tissue thickness and postoperative dysphagia were analyzed on the day of surgery, and 2 weeks and 6 months postoperatively. The Zero-P group showed same or favorable clinical and radiological outcomes compared with the CCP group. Postoperative dysphagia was significantly low in the Zero-P group. Application of Zero-P may achieve favorable outcomes and reduce postoperative dysphagia in single level ACDF.

  20. Auditor recommendations resulting from three clinical audit rounds in Finnish radiology units.

    PubMed

    Miettunen, Kirsi; Metsälä, Eija

    2017-06-01

    Background The purpose of clinical audits performed in radiology units is to reduce the radiation dose of patients and staff and to implement evidence-based best practices. Purpose To describe auditor recommendations in three Finnish clinical audit rounds performed in 2002-2014, and to determine if auditor recommendations have had any impact on improving medical imaging practice. Material and Methods The retrospective observational study was performed in radiology units holding a radiation safety license issued by the Finnish Radiation and Nuclear Safety Authority. The data comprised a systematic sample (n = 120) of auditor reports produced in three auditing rounds in these units during the years 2002-2014. The data were analyzed by descriptive methods and by using the Friedman two-way ANOVA test. Results The number of auditor recommendations given varied between clinical audit rounds and according to the type of imaging unit, as well as according to calculation method. Proportionally, the most recommendations in all three clinical audit rounds were given about defining and using quality assurance functions and about guidelines and practices for carrying out procedures involving radiation exposure. Demanding radiology units improved their practices more than basic imaging units towards the third round. Conclusion Auditor recommendations help to address the deficiencies in imaging practices. There is a need to develop uniform guidelines and to provide tutoring for clinical auditors in order to produce comparable clinical audit results.

  1. Improving diversity, inclusion, and representation in radiology and radiation oncology part 2: challenges and recommendations.

    PubMed

    Lightfoote, Johnson B; Fielding, Julia R; Deville, Curtiland; Gunderman, Richard B; Morgan, Gail N; Pandharipande, Pari V; Duerinckx, Andre J; Wynn, Raymond B; Macura, Katarzyna J

    2014-08-01

    The ACR Commission for Women and General Diversity is committed to identifying barriers to a diverse physician workforce in radiology and radiation oncology (RRO), and to offering policy recommendations to overcome these barriers. Part 2 of a 2-part position article from the commission addresses issues regarding diversity and inclusion in the context of career choices and professional advancement. Barriers to improving diversity and representation in RRO are reviewed. Discussion focuses on the development and implementation of concrete strategies designed to eliminate the current subspecialty disparity and highlights the need for the ACR to introduce programs and incentives with targeted and achievable goals with measurable outcomes. Recommendations are made aimed at fostering an environment of inclusion and diversity, so as to secure a successful future for all members of the RRO workforce. The future of radiology will be enhanced by increasing diversity and representation in the professional workforce, which will allow us to better address the varied needs of increasingly diverse patient populations, and to mitigate disparities in healthcare access, delivery, and outcomes. By leveraging diverse backgrounds, experiences, and skills of those in RRO, we will create new, effective ways to not only educate our trainees, medical colleagues, and patients but also improve delivery of health care and our service to society. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Cost accounting in radiology: new directions and importance for policy.

    PubMed

    Muchantef, Karl; Forman, Howard P

    2005-12-01

    The purpose of this article is to promote insight into radiology costs through improvements in assessing patient-level cost data. Accurate patient costing is a prerequisite for establishing a proper payment system-one where the price paid for a service approximates the cost of delivering that service. In the absence of an accurate payment scheme, margins can vary significantly from one patient to the next. The resulting financial incentives skew the radiology marketplace away from the provision of efficient and appropriate care toward the selection of patients whose costs are low relative to reimbursements.

  3. Natural radionuclide and radiological assessment of building materials in high background radiation areas of Ramsar, Iran.

    PubMed

    Bavarnegin, Elham; Moghaddam, Masoud Vahabi; Fathabadi, Nasrin

    2013-04-01

    Building materials, collected from different sites in Ramsar, a northern coastal city in Iran, were analyzed for their natural radionuclide contents. The measurements were carried out using a high resolution high purity Germanium (HPGe) gamma-ray spectrometer system. The activity concentration of (226)Ra, (232)Th, and (40)K content varied from below the minimum detection limit up to 86,400 Bqkg(-1), 187 Bqkg(-1), and 1350 Bqkg(-1), respectively. The radiological hazards incurred from the use of these building materials were estimated through various radiation hazard indices. The result of this survey shows that values obtained for some samples are more than the internationally accepted maximum limits and as such, the use of them as a building material pose significant radiation hazard to individuals.

  4. A rapid method for the simultaneous determination of gross alpha and beta activities in water samples using a low background liquid scintillation counter.

    PubMed

    Sanchez-Cabeza, J A; Pujol, L

    1995-05-01

    The radiological examination of water requires a rapid screening technique that permits the determination of the gross alpha and beta activities of each sample in order to decide if further radiological analyses are necessary. In this work, the use of a low background liquid scintillation system (Quantulus 1220) is proposed to simultaneously determine the gross activities in water samples. Liquid scintillation is compared to more conventional techniques used in most monitoring laboratories. In order to determine the best counting configuration of the system, pulse shape discrimination was optimized for 6 scintillant/vial combinations. It was concluded that the best counting configuration was obtained with the scintillation cocktail Optiphase Hisafe 3 in Zinsser low diffusion vials. The detection limits achieved were 0.012 Bq L-1 and 0.14 Bq L-1 for gross alpha and beta activity respectively, after a 1:10 concentration process by simple evaporation and for a counting time of only 360 min. The proposed technique is rapid, gives spectral information, and is adequate to determine gross activities according to the World Health Organization (WHO) guideline values.

  5. Radioactivity backgrounds in ZEPLIN-III

    NASA Astrophysics Data System (ADS)

    Araújo, H. M.; Akimov, D. Yu.; Barnes, E. J.; Belov, V. A.; Bewick, A.; Burenkov, A. A.; Chepel, V.; Currie, A.; Deviveiros, L.; Edwards, B.; Ghag, C.; Hollingsworth, A.; Horn, M.; Kalmus, G. E.; Kobyakin, A. S.; Kovalenko, A. G.; Lebedenko, V. N.; Lindote, A.; Lopes, M. I.; Lüscher, R.; Majewski, P.; Murphy, A. St. J.; Neves, F.; Paling, S. M.; Pinto da Cunha, J.; Preece, R.; Quenby, J. J.; Reichhart, L.; Scovell, P. R.; Silva, C.; Solovov, V. N.; Smith, N. J. T.; Smith, P. F.; Stekhanov, V. N.; Sumner, T. J.; Thorne, C.; Walker, R. J.

    2012-03-01

    We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75 ± 0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level Monte Carlo simulations propagating the effects of the radiological contamination measured for materials employed in the experiment. Neutron elastic scattering is predicted to yield 3.05 ± 0.5 nuclear recoils with energy 5-50 keV per year, which translates to an expectation of 0.4 events in a 1 yr dataset in anti-coincidence with the veto detector for realistic signal acceptance. Less obvious background sources are discussed, especially in the context of future experiments. These include contamination of scintillation pulses with Cherenkov light from Compton electrons and from β activity internal to photomultipliers, which can increase the size and lower the apparent time constant of the scintillation response. Another challenge is posed by multiple-scatter γ-rays with one or more vertices in regions that yield no ionisation. If the discrimination power achieved in the first run can be replicated, ZEPLIN-III should reach a sensitivity of ˜1 × 10-8pb · yr to the scalar WIMP-nucleon elastic cross-section, as originally conceived.

  6. Restriction of ACGME fellowships to candidates completing US and Canadian accredited residencies: level of support and expected consequences.

    PubMed

    Orru', Emanuele; Arenson, Ronald A; Schaefer, Pamela W; Mukherji, Suresh K; Yousem, David M

    2014-08-01

    The aim of this study was to determine the level of support for the proposal to restrict ACGME-accredited fellowships to candidates who completed residencies accredited by the ACGME or the Royal College of Physicians and Surgeons of Canada. Perceptions of foreign-trained international medical graduates during and after fellowships were also assessed. An e-mail survey was sent to the members of the organizations that represent academic chairpersons (the Society of Chairs of Academic Radiology Departments) and radiology residency and fellowship program directors (the Association of Program Directors in Radiology) and to the program directors of the largest American radiology subspecialty society (the American Society of Neuroradiology). Results were analyzed separately for each of the 3 societies interviewed and then as a composite report for all 3 societies. Approximately 60% of the respondents said that they have offered at least one fellowship or faculty position to foreign-trained applicants in the past 5 years. More than 70% of the respondents said that these doctors performed equally to or better than American-trained ones both clinically and academically. The majority of members of all 3 societies responding opposed enactment of the rule, with the American Society of Neuroradiology being the most disapproving. The main concerns of those supporting the new rule were the inhomogeneous and sometimes unknown levels of training of the foreign-trained doctors and the need to favor American graduates. Those opposed were mostly worried about diminishing the quality of fellowship candidates, programs being unable to fill their positions, and a decrease in academic-oriented people. Most respondents opposed the proposed rule. The majority were supportive of foreign-trained physicians continuing their training in the United States. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Radiological Instrumentation Assessment for King County Wastewater Treatment Division

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strom, Daniel J.; McConn, Ronald J.; Brodzinski, Ronald L.

    2005-05-19

    The King County Wastewater Treatment Division (WTD) have concern about the aftermath of a radiological dispersion event (RDE) leading to the introduction of significant quantities of radioactive material into its combined sanitary and storm sewer system. Radioactive material could come from the use of a radiological dispersion device (RDD). RDDs include "dirty bombs" that are not nuclear detonations but are explosives designed to spread radioactive material. Radioactive material also could come from deliberate introduction or dispersion of radioactive material into the environment, including waterways and water supply systems. Volume 2 of PNNL-15163 assesses the radiological instrumentation needs for detection ofmore » radiological or nuclear terrorism, in support of decisions to treat contaminated wastewater or to bypass the West Point Treatment Plant (WPTP), and in support of radiation protection of the workforce, the public, and the infrastructure of the WPTP. Fixed radiation detection instrumentation should be deployed in a defense-in-depth system that provides 1) early warning of significant radioactive material on the way to the WPTP, including identification of the radionuclide(s) and estimates of the soluble concentrations, with a floating detector located in the wet well at the Interbay Pump Station and telemetered via the internet to all authorized locations; 2) monitoring at strategic locations within the plant, including 2a) the pipe beyond the hydraulic ram in the bar screen room; 2b) above the collection funnels in the fine grit facility; 2c) in the sampling tank in the raw sewage pump room; and 2d) downstream of the concentration facilities that produce 6% blended and concentrated biosolids. Engineering challenges exist for these applications. It is necessary to deploy both ultra-sensitive detectors to provide early warning and identification and detectors capable of functioning in high-dose rate environments that are likely under some scenarios, capable of functioning from 10 microrems per hour (background) up to 1000 rems per hour. Software supporting fixed spectroscopic detectors is needed to provide prompt, reliable, and simple interpretations of spectroscopic outputs that are of use to operators and decision-makers. Software to provide scientists and homeland security personnel with sufficient technical detail for identification, quantification, waste management decisions, and for the inevitable forensic and attribution needs must be developed. Computational modeling using MCNP software has demonstrated that useful detection capabilities can be deployed. In particular, any of the isotopes examined can be detected at levels between 0.01 and 0.1 μCi per gallon. General purpose instruments that can be used to determine the nature and extent of radioactive contamination and measure radiation levels for purposes of protecting personnel and members of the public should be available. One or more portable radioisotope identifiers (RIIDs) should be available to WTD personnel. Small, portable battery-powered personal radiation monitors should be widely available WTD personnel. The personal monitors can be used for personal and group radiation protection decisions, and to alert management to the need to get expert backup. All considerations of radiological instrumentation require considerations of training and periodic retraining of personnel, as well as periodic calibration and maintenance of instruments. Routine “innocent” alarms will occur due to medical radionuclides that are legally discharged into sanitary sewers on a daily basis.« less

  8. ICRP PUBLICATION 122: radiological protection in geological disposal of long-lived solid radioactive waste.

    PubMed

    Weiss, W; Larsson, C-M; McKenney, C; Minon, J-P; Mobbs, S; Schneider, T; Umeki, H; Hilden, W; Pescatore, C; Vesterlind, M

    2013-06-01

    This report updates and consolidates previous recommendations of the International Commission on Radiological Protection (ICRP) related to solid waste disposal (ICRP, 1985, 1997b, 1998). The recommendations given apply specifically to geological disposal of long-lived solid radioactive waste. The report explains how the ICRP system of radiological protection described in Publication 103 (ICRP, 2007) can be applied in the context of the geological disposal of long-lived solid radioactive waste. Although the report is written as a standalone document, previous ICRP recommendations not dealt with in depth in the report are still valid. The 2007 ICRP system of radiological protection evolves from the previous process-based protection approach relying on the distinction between practices and interventions by moving to an approach based on the distinction between three types of exposure situation: planned, emergency and existing. The Recommendations maintains the Commission's three fundamental principles of radiological protection namely: justification, optimisation of protection and the application of dose limits. They also maintain the current individual dose limits for effective dose and equivalent dose from all regulated sources in planned exposure situations. They re-enforce the principle of optimisation of radiological protection, which applies in a similar way to all exposure situations, subject to restrictions on individual doses: constraints for planned exposure situations, and reference levels for emergency and existing exposure situations. The Recommendations also include an approach for developing a framework to demonstrate radiological protection of the environment. This report describes the different stages in the life time of a geological disposal facility, and addresses the application of relevant radiological protection principles for each stage depending on the various exposure situations that can be encountered. In particular, the crucial factor that influences the application of the protection system over the different phases in the life time of a disposal facility is the level of oversight or 'watchful care' that is present. The level of oversight affects the capability to control the source, i.e. the waste and the repository, and to avoid or reduce potential exposures. Three main time frames are considered: time of direct oversight, when the disposal facility is being implemented and is under active supervision; time of indirect oversight, when the disposal facility is sealed and oversight is being exercised by regulators or special administrative bodies or society at large to provide additional assurance on behalf of society; and time of no oversight, when oversight is no longer exercised in case memory of the disposal facility is lost. Copyright © 2013. Published by Elsevier Ltd.

  9. Identification of Long Bone Fractures in Radiology Reports Using Natural Language Processing to Support Healthcare Quality Improvement

    PubMed Central

    Masino, Aaron J.; Casper, T. Charles; Dean, Jonathan M.; Bell, Jamie; Enriquez, Rene; Deakyne, Sara; Chamberlain, James M.; Alpern, Elizabeth R.

    2016-01-01

    Summary Background Important information to support healthcare quality improvement is often recorded in free text documents such as radiology reports. Natural language processing (NLP) methods may help extract this information, but these methods have rarely been applied outside the research laboratories where they were developed. Objective To implement and validate NLP tools to identify long bone fractures for pediatric emergency medicine quality improvement. Methods Using freely available statistical software packages, we implemented NLP methods to identify long bone fractures from radiology reports. A sample of 1,000 radiology reports was used to construct three candidate classification models. A test set of 500 reports was used to validate the model performance. Blinded manual review of radiology reports by two independent physicians provided the reference standard. Each radiology report was segmented and word stem and bigram features were constructed. Common English “stop words” and rare features were excluded. We used 10-fold cross-validation to select optimal configuration parameters for each model. Accuracy, recall, precision and the F1 score were calculated. The final model was compared to the use of diagnosis codes for the identification of patients with long bone fractures. Results There were 329 unique word stems and 344 bigrams in the training documents. A support vector machine classifier with Gaussian kernel performed best on the test set with accuracy=0.958, recall=0.969, precision=0.940, and F1 score=0.954. Optimal parameters for this model were cost=4 and gamma=0.005. The three classification models that we tested all performed better than diagnosis codes in terms of accuracy, precision, and F1 score (diagnosis code accuracy=0.932, recall=0.960, precision=0.896, and F1 score=0.927). Conclusions NLP methods using a corpus of 1,000 training documents accurately identified acute long bone fractures from radiology reports. Strategic use of straightforward NLP methods, implemented with freely available software, offers quality improvement teams new opportunities to extract information from narrative documents. PMID:27826610

  10. Development of RAD-Score: A Tool to Assess the Procedural Competence of Diagnostic Radiology Residents.

    PubMed

    Isupov, Inga; McInnes, Matthew D F; Hamstra, Stan J; Doherty, Geoffrey; Gupta, Ashish; Peddle, Susan; Jibri, Zaid; Rakhra, Kawan; Hibbert, Rebecca M

    2017-04-01

    The purpose of this study is to develop a tool to assess the procedural competence of radiology trainees, with sources of evidence gathered from five categories to support the construct validity of tool: content, response process, internal structure, relations to other variables, and consequences. A pilot form for assessing procedural competence among radiology residents, known as the RAD-Score tool, was developed by evaluating published literature and using a modified Delphi procedure involving a group of local content experts. The pilot version of the tool was tested by seven radiology department faculty members who evaluated procedures performed by 25 residents at one institution between October 2014 and June 2015. Residents were evaluated while performing multiple procedures in both clinical and simulation settings. The main outcome measure was the percentage of residents who were considered ready to perform procedures independently, with testing conducted to determine differences between levels of training. A total of 105 forms (for 52 procedures performed in a clinical setting and 53 procedures performed in a simulation setting) were collected for a variety of procedures (eight vascular or interventional, 42 body, 12 musculoskeletal, 23 chest, and 20 breast procedures). A statistically significant difference was noted in the percentage of trainees who were rated as being ready to perform a procedure independently (in postgraduate year [PGY] 2, 12% of residents; in PGY3, 61%; in PGY4, 85%; and in PGY5, 88%; p < 0.05); this difference persisted in the clinical and simulation settings. User feedback and psychometric analysis were used to create a final version of the form. This prospective study describes the successful development of a tool for assessing the procedural competence of radiology trainees with high levels of construct validity in multiple domains. Implementation of the tool in the radiology residency curriculum is planned and can play an instrumental role in the transition to competency-based radiology training.

  11. Application of Analytical Hierarchy Process Approach for Service Quality Evaluation in Radiology Departments: A Cross-Sectional Study

    PubMed Central

    Alimohammadzadeh, Khalil; Bahadori, Mohammadkarim; Hassani, Fariba

    2016-01-01

    Background: Radiology department as a service provider organization requires realization of quality concept concerning service provisioning knowledge, satisfaction and all issues relating to the customer as well as quality assurance and improvement issues. At present, radiology departments in hospitals are regarded as income generating units and they should continuously seek performance improvement so that they can survive in the changing and competitive environment of the health care sector. Objectives: The aim of this study was to propose a method for ranking of radiology departments in selected hospitals of Tehran city using analytical hierarchical process (AHP) and quality evaluation of their service in 2015. Materials and Methods: This study was an applied and cross-sectional study, carried out in radiology departments of 6 Tehran educational hospitals in 2015. The hospitals were selected using non-probability and purposeful method. Data gathering was performed using customized joint commission international (JCI) standards. Expert Choice 10.0 software was used for data analysis. AHP method was used for prioritization. Results: “Management and empowerment of human resources’’ (weight = 0.465) and “requirements and facilities” (weight = 0.139) were of highest and lowest significance respectively in the overall ranking of the hospitals. MS (weight = 0.316), MD (weight = 0.259), AT (weight = 0.14), TS (weight = 0.108), MO (weight = 0.095), and LH (0.082) achieved the first to sixth rankings respectively. Conclusion: The use of AHP method can be promising for fostering the evaluation method and subsequently promotion of the efficiency and effectiveness of the radiology departments. The present model can fill in the gap in the accreditation system of the country’s hospitals in respect with ranking and comparing them considering the significance and value of each individual criteria and standard. Accordingly, it can predict an integration of qualitative and quantitative criteria involved and thereby take a decisive step towards further efficiency and effectiveness of the health care evaluation systems. PMID:27127577

  12. Educational Impact of Trainee-Facilitated Head and Neck Radiology-Pathology Correlation Conferences.

    PubMed

    Ginat, Daniel Thomas; Cipriani, Nicole A; Christoforidis, Gregory

    2018-05-17

    The goal of this study was to evaluate the benefits of resident and fellow-facilitated radiology-pathology head and neck conferences. A total of seven resident-facilitated and six fellow-facilitated head and neck radiology-pathology cases were presented as part of the radiology department conference series. The radiology residents were surveyed regarding the perceived quality and effectiveness of the fellow-facilitated sessions. The number of publications yielded from all the cases presented was tracked. Overall, the residents assessed the quality of the fellow-facilitated conferences with an average score of 3.9 out of 5 and the overall helpfulness with an average of 3.5 out of 5. The overall average level of resident understanding among the residents for the topics presented to them by the fellows at baseline was 2.5 out of 5 and 3.4 out of 5 after the presentations, which was a significant increase (p-value < 0.01). There were three peer-reviewed publications generated from the resident presentations and four peer-reviewed publications generated from the fellow presentations, which represents a 54% publication rate collectively. Therefore, trainee-facilitated head and neck radiology-pathology conferences at our institution provide added learning and scholarly activity opportunities.

  13. Validation of Case Finding Algorithms for Hepatocellular Cancer from Administrative Data and Electronic Health Records using Natural Language Processing

    PubMed Central

    Sada, Yvonne; Hou, Jason; Richardson, Peter; El-Serag, Hashem; Davila, Jessica

    2013-01-01

    Background Accurate identification of hepatocellular cancer (HCC) cases from automated data is needed for efficient and valid quality improvement initiatives and research. We validated HCC ICD-9 codes, and evaluated whether natural language processing (NLP) by the Automated Retrieval Console (ARC) for document classification improves HCC identification. Methods We identified a cohort of patients with ICD-9 codes for HCC during 2005–2010 from Veterans Affairs administrative data. Pathology and radiology reports were reviewed to confirm HCC. The positive predictive value (PPV), sensitivity, and specificity of ICD-9 codes were calculated. A split validation study of pathology and radiology reports was performed to develop and validate ARC algorithms. Reports were manually classified as diagnostic of HCC or not. ARC generated document classification algorithms using the Clinical Text Analysis and Knowledge Extraction System. ARC performance was compared to manual classification. PPV, sensitivity, and specificity of ARC were calculated. Results 1138 patients with HCC were identified by ICD-9 codes. Based on manual review, 773 had HCC. The HCC ICD-9 code algorithm had a PPV of 0.67, sensitivity of 0.95, and specificity of 0.93. For a random subset of 619 patients, we identified 471 pathology reports for 323 patients and 943 radiology reports for 557 patients. The pathology ARC algorithm had PPV of 0.96, sensitivity of 0.96, and specificity of 0.97. The radiology ARC algorithm had PPV of 0.75, sensitivity of 0.94, and specificity of 0.68. Conclusion A combined approach of ICD-9 codes and NLP of pathology and radiology reports improves HCC case identification in automated data. PMID:23929403

  14. Meta-Generalis: A Novel Method for Structuring Information from Radiology Reports

    PubMed Central

    Barbosa, Flavio; Traina, Agma Jucci

    2016-01-01

    Summary Background A structured report for imaging exams aims at increasing the precision in information retrieval and communication between physicians. However, it is more concise than free text and may limit specialists’ descriptions of important findings not covered by pre-defined structures. A computational ontological structure derived from free texts designed by specialists may be a solution for this problem. Therefore, the goal of our study was to develop a methodology for structuring information in radiology reports covering specifications required for the Brazilian Portuguese language, including the terminology to be used. Methods We gathered 1,701 radiological reports of magnetic resonance imaging (MRI) studies of the lumbosacral spine from three different institutions. Techniques of text mining and ontological conceptualization of lexical units extracted were used to structure information. Ten radiologists, specialists in lumbosacral MRI, evaluated the textual superstructure and terminology extracted using an electronic questionnaire. Results The established methodology consists of six steps: 1) collection of radiology reports of a specific MRI examination; 2) textual decomposition; 3) normalization of lexical units; 4) identification of textual superstructures; 5) conceptualization of candidate-terms; and 6) evaluation of superstructures and extracted terminology by experts using an electronic questionnaire. Three different textual superstructures were identified, with terminological variations in the names of their textual categories. The number of candidate-terms conceptualized was 4,183, yielding 727 concepts. There were a total of 13,963 relationships between candidate-terms and concepts and 789 relationships among concepts. Conclusions The proposed methodology allowed structuring information in a more intuitive and practical way. Indications of three textual superstructures, extraction of lexicon units and the normalization and ontologically conceptualization were achieved while maintaining references to their respective categories and free text radiology reports. PMID:27580980

  15. Career advancement of men and women in academic radiology: is the playing field level?

    PubMed

    Vydareny, K H; Waldrop, S M; Jackson, V P; Manaster, B J; Nazarian, G K; Reich, C A; Ruzal-Shapiro, C B

    2000-07-01

    The authors' purposes were to determine if there are gender differences in the speed of promotion and/or academic productivity in academic radiology and if this situation had changed since a previous study was performed in 1987. Surveys were distributed to faculty members of academic radiology departments in May 1997. A total of 707 surveys were analyzed according to gender for time at rank for assistant and associate professor levels, in relation to publication rate, grant funding rate, and distribution of professional time. There was no difference between genders in the time at assistant professor rank. Among all current professors, women had been associate professors longer than men, but there was no difference between genders for those who had been in academic radiology for less than 15 years. There was no gender difference at any rank in the rate of publishing original articles. There was no difference in funding rates, although men had more total grant support. Male associate professors reported spending more time in administration and slightly more time in total hours at work than did their female colleagues, and male professors spent slightly more time teaching residents. Otherwise, there is no difference in how men and women at any rank spend their professional time. There are, however, lower percentages of women in tenured positions and in the uppermost levels of departmental administration. The time at rank for men and women and their rate of publication appear to have equalized. Women still are underrepresented at the uppermost levels of departmental administration, however, and are less likely than men to hold tenured positions.

  16. Contributions of Various Radiological Sources to Background in a Suburban Environment

    DOE PAGES

    Milvenan, Richard D.; Hayes, Robert B.

    2016-11-01

    This work is a brief overview and comparison of dose rates stemming from both indoor and outdoor natural background radiation and household objects within a suburban environment in North Carolina. Combined gamma and beta dose rates were taken from indoor objects that ranged from the potassium in fruit to the americium in smoke detectors. For outdoor measurements, various height and time data samples were collected to show fluctuations in dose rate due to temperature inversion and geometric attenuation. Although each sample tested proved to have a statistically significant increase over background using Students t-test, no sample proved to be moremore » than a minor increase in natural radiation dose. Furthermore, the relative contributions from natural radioactivity such as potassium in foods and common household items are shown to be easily distinguished from background using standard handheld instrumentation when applied in a systematic, methodological manner.« less

  17. Contributions of Various Radiological Sources to Background in a Suburban Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milvenan, Richard D.; Hayes, Robert B.

    This work is a brief overview and comparison of dose rates stemming from both indoor and outdoor natural background radiation and household objects within a suburban environment in North Carolina. Combined gamma and beta dose rates were taken from indoor objects that ranged from the potassium in fruit to the americium in smoke detectors. For outdoor measurements, various height and time data samples were collected to show fluctuations in dose rate due to temperature inversion and geometric attenuation. Although each sample tested proved to have a statistically significant increase over background using Students t-test, no sample proved to be moremore » than a minor increase in natural radiation dose. Furthermore, the relative contributions from natural radioactivity such as potassium in foods and common household items are shown to be easily distinguished from background using standard handheld instrumentation when applied in a systematic, methodological manner.« less

  18. Early results of one-stage correction for hip instability in cerebral palsy.

    PubMed

    Kim, Hui Taek; Jang, Jae Hoon; Ahn, Jae Min; Lee, Jong Seo; Kang, Dong Joon

    2012-06-01

    We evaluated the clinical and radiological results of one-stage correction for cerebral palsy patients. We reviewed clinical outcomes and radiologic indices of 32 dysplastic hips in 23 children with cerebral palsy (13 males, 10 females; mean age, 8.6 years). Ten hips had dislocation, while 22 had subluxation. Preoperative Gross Motor Function Classification System (GMFCS) scores of the patients were as follows; level V (13 patients), level IV (9), and level III (1). Acetabular deficiency was anterior in 5 hips, superolateral in 7, posterior in 11 and mixed in 9, according to 3 dimensional computed tomography. The combined surgery included open reduction of the femoral head, release of contracted muscles, femoral shortening varus derotation osteotomy and the modified Dega osteotomy. Hip range of motion, GMFCS level, acetabular index, center-edge angle and migration percentage were measured before and after surgery. The mean follow-up period was 28.1 months. Hip abduction (median, 40°), sitting comfort and GMFCS level were improved after surgery, and pain was decreased. There were two cases of femoral head avascular necrosis, but no infection, nonunion, resubluxation or redislocation. All radiologic indices showed improvement after surgery. A single event multilevel surgery including soft tissue, pelvic and femoral side correction is effective in treating spastic dislocation of the hip in cerebral palsy.

  19. Mitigating Backgrounds with a Novel Thin-Film Cathode in the DRIFT-IId Dark Matter Detector

    NASA Astrophysics Data System (ADS)

    Miller, Eric H.

    The nature of dark matter, which comprises 85% of the matter density in the universe, is a major outstanding question in physics today. The standard hypothesis is that the dark matter is a new weakly interacting massive particle, which is present throughout the galaxy. These particles could interact within detectors on Earth, producing low-energy nuclear recoils. Two distinctive signatures arise from the solar motion through the galaxy. The DRIFT experiment aims to measure one of these, the directional signature that is based on the sidereal modulation of the nuclear recoil directions. Although DRIFT has demonstrated its capability for detecting this signature, it has been plagued by a large number of backgrounds that have limited its reach. The focus of this thesis is on characterizing these backgrounds and describing techniques that have essentially eliminated them. The background events in the DRIFT-IId detector are predominantly caused by alpha decays on the central cathode in which the alpha particles completely or partially absorbed by the cathode material. This thesis describes the installation a 0.9 mum thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of cathode (wire, thin-film, and radiologically clean thin-film) with a focus on identifying and quantifying the sources of alpha decay backgrounds, as well as their contributions to the background rate in the detector. This in-situ study is based on alpha range spectroscopy and the determination of the absolute alpha detection efficiency. The results for the final radiologically clean version of the cathode give a contamination of 3.3 +/- 0.1 ppt 234U and 73 +/- 2 ppb 238U, and an efficiency for rejecting an RPR from an alpha decay that is a factor 70 +/- 20 higher than for the original wire cathode. Along with other background reduction measures, the thin-film cathode has reduced the observed background rate from 130/day to 1.7/day in the DRIFT experiment. The complete elimination of the remaining RPR backgrounds requires fiducialization of the detector along the drift direction. We describe two methods for doing this: one involving the detection of positive ions at the cathode, and the other using multiple species of charge carriers with variable drift speeds. With the recent successful implementation of the latter technique, the DRIFT experiment has run background-free for 46 days.

  20. Implementation of Certified EHR, Patient Portal, and "Direct" Messaging Technology in a Radiology Environment Enhances Communication of Radiology Results to Both Referring Physicians and Patients.

    PubMed

    Reicher, Joshua Jay; Reicher, Murray Aaron

    2016-06-01

    Since 2009, the Federal government distributed over $29 billion to providers who were adopting compliant electronic health record (EHR) technology. With a focus on radiology, we explore how EHR technology impacts interoperability with referring clinicians' EHRs and patient engagement. We also discuss the high-level details of contributing supporting frameworks, specifically Direct messaging and health information service provider (HISP) technology. We characterized Direct messaging, a secure e-mail-like protocol built to allow exchange of encrypted health information online, and the new supporting HISP infrastructure. Statistics related to both the testing and active use of this framework were obtained from DirectTrust.org, an organization whose framework supports Direct messaging use by healthcare organizations. To evaluate patient engagement, we obtained usage data from a radiology-centric patient portal between 2014 and 2015, which in some cases included access to radiology reports. Statistics from 2013 to 2015 showed a rise in issued secure Direct addresses from 8724 to 752,496; a rise in the number of participating healthcare organizations from 667 to 39,751; and a rise in the secure messages sent from 122,842 to 27,316,438. Regarding patient engagement, an average of 234,679 patients per month were provided portal access, with 86,400 patients per month given access to radiology reports. Availability of radiology reports online was strongly associated with increased system usage, with a likelihood ratio of 2.63. The use of certified EHR technology and Direct messaging in the practice of radiology allows for the communication of patient information and radiology results with referring clinicians and increases patient use of patient portal technology, supporting bidirectional radiologist-patient communication.

  1. Radiation protection aspects of the cosmic radiation exposure of aircraft crew.

    PubMed

    Bartlett, D T

    2004-01-01

    Aircraft crew and frequent flyers are exposed to elevated levels of cosmic radiation of galactic and solar origin and secondary radiation produced in the atmosphere, the aircraft structure and its contents. Following recommendations of the International Commission on Radiological Protection in Publication 60, the European Union introduced a revised Basic Safety Standards Directive, which included exposure to natural sources of ionising radiation, including cosmic radiation, as occupational exposure. The revised Directive has been incorporated into laws and regulations in the European Union Member States. Where the assessment of the occupational exposure of aircraft crew is necessary, the preferred approach to monitoring is by the recording of staff flying times and calculated route doses. Route doses are to be validated by measurements. This paper gives the general background, and considers the radiation protection aspects of the cosmic radiation exposure of aircraft crew, with the focus on the situation in Europe.

  2. Data-driven approach for creating synthetic electronic medical records.

    PubMed

    Buczak, Anna L; Babin, Steven; Moniz, Linda

    2010-10-14

    New algorithms for disease outbreak detection are being developed to take advantage of full electronic medical records (EMRs) that contain a wealth of patient information. However, due to privacy concerns, even anonymized EMRs cannot be shared among researchers, resulting in great difficulty in comparing the effectiveness of these algorithms. To bridge the gap between novel bio-surveillance algorithms operating on full EMRs and the lack of non-identifiable EMR data, a method for generating complete and synthetic EMRs was developed. This paper describes a novel methodology for generating complete synthetic EMRs both for an outbreak illness of interest (tularemia) and for background records. The method developed has three major steps: 1) synthetic patient identity and basic information generation; 2) identification of care patterns that the synthetic patients would receive based on the information present in real EMR data for similar health problems; 3) adaptation of these care patterns to the synthetic patient population. We generated EMRs, including visit records, clinical activity, laboratory orders/results and radiology orders/results for 203 synthetic tularemia outbreak patients. Validation of the records by a medical expert revealed problems in 19% of the records; these were subsequently corrected. We also generated background EMRs for over 3000 patients in the 4-11 yr age group. Validation of those records by a medical expert revealed problems in fewer than 3% of these background patient EMRs and the errors were subsequently rectified. A data-driven method was developed for generating fully synthetic EMRs. The method is general and can be applied to any data set that has similar data elements (such as laboratory and radiology orders and results, clinical activity, prescription orders). The pilot synthetic outbreak records were for tularemia but our approach may be adapted to other infectious diseases. The pilot synthetic background records were in the 4-11 year old age group. The adaptations that must be made to the algorithms to produce synthetic background EMRs for other age groups are indicated.

  3. Predictive Modeling of Terrestrial Radiation Exposure from Geologic Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malchow, Russell L.; Haber, Daniel University of Nevada, Las Vegas; Burnley, Pamela

    2015-01-01

    Aerial gamma ray surveys are important for those working in nuclear security and industry for determining locations of both anthropogenic radiological sources and natural occurrences of radionuclides. During an aerial gamma ray survey, a low flying aircraft, such as a helicopter, flies in a linear pattern across the survey area while measuring the gamma emissions with a sodium iodide (NaI) detector. Currently, if a gamma ray survey is being flown in an area, the only way to correct for geologic sources of gamma rays is to have flown the area previously. This is prohibitively expensive and would require complete nationalmore » coverage. This project’s goal is to model the geologic contribution to radiological backgrounds using published geochemical data, GIS software, remote sensing, calculations, and modeling software. K, U and Th are the three major gamma emitters in geologic material. U and Th are assumed to be in secular equilibrium with their daughter isotopes. If K, U, and Th abundance values are known for a given geologic unit the expected gamma ray exposure rate can be calculated using the Grasty equation or by modeling software. Monte Carlo N-Particle Transport software (MCNP), developed by Los Alamos National Laboratory, is modeling software designed to simulate particles and their interactions with matter. Using this software, models have been created that represent various lithologies. These simulations randomly generate gamma ray photons at energy levels expected from natural radiologic sources. The photons take a random path through the simulated geologic media and deposit their energy at the end of their track. A series of nested spheres have been created and filled with simulated atmosphere to record energy deposition. Energies deposited are binned in the same manner as the NaI detectors used during an aerial survey. These models are used in place of the simplistic Grasty equation as they take into account absorption properties of the lithology which the simplistic equation ignores.« less

  4. The adult spinal cord injury without radiographic abnormalities syndrome: magnetic resonance imaging and clinical findings in adults with spinal cord injuries having normal radiographs and computed tomography studies.

    PubMed

    Kasimatis, Georgios B; Panagiotopoulos, Elias; Megas, Panagiotis; Matzaroglou, Charalambos; Gliatis, John; Tyllianakis, Minos; Lambiris, Elias

    2008-07-01

    Spinal cord injury without radiographic abnormalities (SCIWORA) is thought to represent mostly a pediatric entity and its incidence in adults is rather underreported. Some authors have also proposed the term spinal cord injury without radiologic evidence of trauma, as more precisely describing the condition of adult SCIWORA in the setting of cervical spondylosis. The purpose of the present study was to evaluate adult patients with cervical spine injuries and radiological-clinical examination discrepancy, and to discuss their characteristics and current management. During a 16-year period, 166 patients with a cervical spine injury were admitted in our institution (Level I trauma center). Upper cervical spine injuries (occiput to C2, 54 patients) were treated mainly by a Halo vest, whereas lower cervical spine injuries (C3-T1, 112 patients) were treated surgically either with an anterior, or posterior procedure, or both. Seven of these 166 patients (4.2%) had a radiologic-clinical mismatch, i.e., they presented with frank spinal cord injury with no signs of trauma, and were included in the study. Magnetic resonance imaging was available for 6 of 7 patients, showing intramedullary signal changes in 5 of 6 patients with varying degrees of compression from the disc and/or the ligamentum flavum, whereas the remaining patient had only traumatic herniation of the intervertebral disc and ligamentum flavum bulging. Follow-up period was 6.4 years on average (1-10 years). This retrospective chart review provides information on adult patients with cervical spinal cord injuries whose radiographs and computed tomography studies were normal. It furthers reinforces the pathologic background of SCIWORA in an adult population, when evaluated by magnetic resonance imaging. Particularly for patients with cervical spondylosis, special attention should be paid with regard to vascular compromise by predisposing factors such as smoking or vascular disease, since they probably contribute in the development of SCIWORA.

  5. How visual search relates to visual diagnostic performance: a narrative systematic review of eye-tracking research in radiology.

    PubMed

    van der Gijp, A; Ravesloot, C J; Jarodzka, H; van der Schaaf, M F; van der Schaaf, I C; van Schaik, J P J; Ten Cate, Th J

    2017-08-01

    Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review of eye-tracking literature in the radiology domain aims to identify visual search patterns associated with high perceptual performance. Databases PubMed, EMBASE, ERIC, PsycINFO, Scopus and Web of Science were searched using 'visual perception' OR 'eye tracking' AND 'radiology' and synonyms. Two authors independently screened search results and included eye tracking studies concerning visual skills in radiology published between January 1, 1994 and July 31, 2015. Two authors independently assessed study quality with the Medical Education Research Study Quality Instrument, and extracted study data with respect to design, participant and task characteristics, and variables. A thematic analysis was conducted to extract and arrange study results, and a textual narrative synthesis was applied for data integration and interpretation. The search resulted in 22 relevant full-text articles. Thematic analysis resulted in six themes that informed the relation between visual search and level of expertise: (1) time on task, (2) eye movement characteristics of experts, (3) differences in visual attention, (4) visual search patterns, (5) search patterns in cross sectional stack imaging, and (6) teaching visual search strategies. Expert search was found to be characterized by a global-focal search pattern, which represents an initial global impression, followed by a detailed, focal search-to-find mode. Specific task-related search patterns, like drilling through CT scans and systematic search in chest X-rays, were found to be related to high expert levels. One study investigated teaching of visual search strategies, and did not find a significant effect on perceptual performance. Eye tracking literature in radiology indicates several search patterns are related to high levels of expertise, but teaching novices to search as an expert may not be effective. Experimental research is needed to find out which search strategies can improve image perception in learners.

  6. CT and MRI imaging of the brain in MELAS syndrome

    PubMed Central

    Pauli, Wojciech; Zarzycki, Artur; Krzyształowski, Adam; Walecka, Anna

    2013-01-01

    Summary Background: MELAS syndrome (mitochondrial myopathy, encephalopathy, lactic acidosis, stroke-like episodes) is a rare, multisystem disorder which belongs to a group of mitochondrial metabolic diseases. As other diseases in this group, it is inherited in the maternal line. Case Report: In this report, we discussed a case of a 10-year-old girl with clinical and radiological picture of MELAS syndrome. We would like to describe characteristic radiological features of MELAS syndrome in CT, MRI and MR spectroscopy of the brain and differential diagnosis. Conclusions: The rarity of this disorder and the complexity of its clinical presentation make MELAS patients among the most difficult to diagnose. Brain imaging studies require a wide differential diagnosis, primarily to distinguish between MELAS and ischemic stroke. Particularly helpful are the MRI and MR spectroscopy techniques. PMID:24115962

  7. Ionizing radiation-induced acoustics for radiotherapy and diagnostic radiology applications.

    PubMed

    Hickling, Susannah; Xiang, Liangzhong; Jones, Kevin C; Parodi, Katia; Assmann, Walter; Avery, Stephen; Hobson, Maritza; El Naqa, Issam

    2018-04-21

    Acoustic waves are induced via the thermoacoustic effect in objects exposed to a pulsed beam of ionizing radiation. This phenomenon has interesting potential applications in both radiotherapy dosimetry and treatment guidance as well as low dose radiological imaging. After initial work in the field in the 1980s and early 1990s, little research was done until 2013 when interest was rejuvenated, spurred on by technological advances in ultrasound transducers and the increasing complexity of radiotherapy delivery systems. Since then, many studies have been conducted and published applying ionizing radiation-induced acoustic principles into three primary research areas: Linear accelerator photon beam dosimetry, proton therapy range verification, and radiological imaging. This review article introduces the theoretical background behind ionizing radiation-induced acoustic waves, summarizes recent advances in the field, and provides an outlook on how the detection of ionizing radiation-induced acoustic waves can be used for relative and in vivo dosimetry in photon therapy, localization of the Bragg peak in proton therapy, and as a low-dose medical imaging modality. Future prospects and challenges for clinical implementation of these techniques are discussed. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Reversible splenial lesion syndrome associated with lobar pneumonia

    PubMed Central

    Li, Chunrong; Wu, Xiujuan; Qi, Hehe; Cheng, Yanwei; Zhang, Bing; Zhou, Hongwei; Lv, Xiaohong; Liu, Kangding; Zhang, Hong-Liang

    2016-01-01

    Abstract Background: Reversible splenial lesion syndrome (RESLES) is a rare clinico-radiological disorder with unclear pathophysiology. Clinically, RESLES is defined as reversible isolated splenial lesions in the corpus callosum, which can be readily identified by magnetic resonance imaging (MRI) and usually resolve completely over a period of time. RESLES could be typically triggered by infection, antiepileptic drugs (AEDs), poisoning, etc. More factors are increasingly recognized. Methods and results: We reported herein an 18-year-old female patient with lobar pneumonia who developed mental abnormalities during hospitalization. An isolated splenial lesion in the corpus callosum was found by head MRI and the lesion disappeared 15 days later. Based on her clinical manifestations and radiological findings, she was diagnosed with lobar pneumonia associated RESLES. We further summarize the up-to-date knowledge about the etiology, possible pathogenesis, clinical manifestations, radiological features, treatment, and prognosis of RESLES. Conclusion: This report contributes to the clinical understanding of RESLES which may present with mental abnormalities after infection. The characteristic imaging of reversible isolated splenial lesions in the corpus callosum was confirmed in this report. The clinical manifestations and lesions on MRI could disappear naturally after 1 month without special treatment. PMID:27684805

  9. Intradiscal injection of simvastatin results in radiologic, histologic, and genetic evidence of disc regeneration in a rat model of degenerative disc disease

    PubMed Central

    Than, Khoi D.; Rahman, Shayan U.; Wang, Lin; Khan, Adam; Kyere, Kwaku A.; Than, Tracey T.; Miyata, Yoshinari; Park, Yoon-Shin; La Marca, Frank; Kim, Hyungjin M.; Zhang, Huina; Park, Paul; Lin, Chia-Ying

    2014-01-01

    BACKGROUND CONTEXT A large percentage of back pain can be attributed to degeneration of the intervertebral disc (IVD). Bone morphogenetic protein-2 (BMP-2) is known to play an important role in chondrogenesis of the IVD. Simvastatin is known to up-regulate expression of BMP-2. Thus, we hypothesized that intradiscal injection of simvastatin in a rat model of degenerative disc disease (DDD) would result in retardation of DDD. PURPOSE To develop a novel conservative treatment for DDD and related discogenic back pain. STUDY DESIGN/SETTING Laboratory investigation. METHODS Disc injury was induced in 272 rats via 21-gauge needle puncture. After 6 weeks, injured discs were treated with simvastatin in a saline or hydrogel carrier. Rats were sacrificed at predetermined time points. Outcome measures assessed were radiologic, histologic, and genetic. Radiologically, the MRI index (number of pixels multiplied by corresponding image densities) was determined. Histologically, disc spaces were read by 3 blinded scorers employing a previously described histological grading scale. Genetically, nuclei pulposi were harvested and polymerase chain reaction was run to determine relative levels of aggrecan, collagen type II, and BMP-2 gene expression. This project was supported by Grant No. R01 AR056649 from NIAMS/NIH. There are no other financial conflicts of interest to report. RESULTS Radiologically, discs treated with 5 mg/mL simvastatin in hydrogel or saline demonstrated MRI indices that were normal through 8 weeks post-treatment, although this was more sustained when delivered in hydrogel. Histologically, discs treated with 5 mg/mL simvastatin in hydrogel demonstrated improved grades in comparison to discs treated at higher doses. Genetically, discs treated with 5 mg/mL of simvastatin in hydrogel demonstrated higher gene expression of aggrecan and collagen type II than control. CONCLUSIONS Degenerate discs treated with 5 mg/mL simvastatin in a hydrogel carrier demonstrated radiographic and histologic features resembling normal, non-injured IVDs. In addition, gene expression of aggrecan and collagen type II (important constituents of the IVD extracellular matrix) was up-regulated in treated discs. Injection of simvastatin into degenerate IVDs may result in retardation of disc degeneration and represents a promising investigational therapy for conservative treatment of DDD. PMID:24291703

  10. Tumor response evaluation after neoadjuvant chemotherapy in locally advanced gastric adenocarcinoma: a prospective, multi-center cohort study

    PubMed Central

    De Martini, Paolo; Ceresoli, Marco; Mari, Giulio M.; Costanzi, Andrea; Maggioni, Dario; Pugliese, Raffaele; Ferrari, Giovanni

    2017-01-01

    Background To verify the prognostic value of the pathologic and radiological tumor response after neoadjuvant chemotherapy in the treatment of locally advanced gastric adenocarcinoma. Methods A total of 67 patients with locally advanced gastric cancer (clinical ≥ T2 or nodal disease and without evidence of distant metastases) underwent perioperative chemotherapy (ECF or ECX regimen) from December 2009 through June 2015 in two surgical units. Histopathological and radiological response to chemotherapy were evaluated by using tumor regression grade (TRG) (Becker’s criteria) and volume change assessed by CT. Results Fifty-one (86%) patients completed all chemotherapy scheduled cycles successfully and surgery was curative (R0) in 64 (97%) subjects. The histopathological analysis showed 19 (29%) specimens with TRG1 (less than 10% of vital tumor left) and 25 (37%) patients had partial or complete response (CR) assessed by CT scan. Median disease free survival (DFS) and overall survival (OS) were 25.70 months (range, 14.52–36.80 months) and 36.60 months (range, 24.3–52.9 months), respectively. The median follow up was 27 months (range, 5.00–68.00 months). Radiological response and TRG were found to be a prognostic factor for OS and DFS, while tumor histology was not significantly related to survival. Conclusions Both radiological response and TRG have been shown as promising survival markers in patients treated with perioperative chemotherapy for locally advanced gastric cancer. Other predictive markers of response to chemotherapy are strongly required. PMID:29299362

  11. Effects of problem-based learning in Chinese radiology education

    PubMed Central

    Zhang, Song; Xu, Jiancheng; Wang, Hongwei; Zhang, Dong; Zhang, Qichuan; Zou, Liguang

    2018-01-01

    Abstract Background: In recent years, the problem-based learning (PBL) teaching method has been extensively applied as an experimental educational method in Chinese radiology education. However, the results of individual studies were inconsistent and inconclusive. A meta-analysis was performed to evaluate the effects of PBL on radiology education in China. Methods: Databases of Chinese and English languages were searched from inception up to November 2017. The standard mean difference (SMD) with its 95% confidence interval (95% CI) was used to determine the over effects of PBL compared with the traditional teaching method. Results: Seventeen studies involving 1487 participants were included in this meta-analysis. Of them, 16 studies provided sufficient data for the pooled analysis and showed that PBL teaching method had a positive effect on achieving higher theoretical scores compared with the traditional teaching method (SMD = 1.20, 95% CI [0.68, 1.71]). Thirteen studies provided sufficient data on skill scores, and a significant difference in favor of PBL was also observed (SMD = 2.10, 95% CI [1.38, 2.83]). Questionnaire surveys were applied in most of the included studies and indicated positive effects of PBL on students’ learning interest, scope of knowledge, team spirit, and oral expression. Conclusion: The result shows that PBL appears to be more effective on radiology education than traditional teaching method in China. However, the heterogeneity of the included studies cannot be neglected. Further well-designed studies about this topic are needed to confirm the above findings. PMID:29489669

  12. Focal role of tolerability and reasonableness in the radiological protection system.

    PubMed

    Schneider, T; Lochard, J; Vaillant, L

    2016-06-01

    The concepts of tolerability and reasonableness are at the core of the International Commission on Radiological Protection (ICRP) system of radiological protection. Tolerability allows the definition of boundaries for implementing ICRP principles, while reasonableness contributes to decisions regarding adequate levels of protection, taking into account the prevailing circumstances. In the 1970s and 1980s, attempts to find theoretical foundations in risk comparisons for tolerability and cost-benefit analysis for reasonableness failed. In practice, the search for a rational basis for these concepts will never end. Making a wise decision will always remain a matter of judgement and will depend on the circumstances as well as the current knowledge and past experience. This paper discusses the constituents of tolerability and reasonableness at the heart of the radiological protection system. It also emphasises the increasing role of stakeholder engagement in the quest for tolerability and reasonableness since Publication 103. © The International Society for Prosthetics and Orthotics.

  13. Coping in a calamity: Radiology during the cloudburst at Leh

    PubMed Central

    Sen, Debraj

    2013-01-01

    The service hospital at Leh is a multispeciality hospital situated at an altitude of 11000 feet above mean sea level. On the nights of 4 and 5 Aug 2010, Leh was struck by a cloudburst leading to mudslides and consequently extensive damage to life and property. Being the only functional hospital, over a period of about 48 hours, 331 casualties were received. 549 casualties were received over the week with 108 admissions, 16 major surgeries and 138 minor surgeries. 178 radiographs, 17 CT scans and 09 ultrasound-colour Doppler examinations were performed on an urgent basis over 48 hours apart from the routine radiological investigations. Apart from chronicling the event, we hope that sharing the unique experience of the Radiology Department in dealing with the large influx of patients would provide an insight into the role of Radiology during the disaster and help in planning and developing management protocols during other calamities. PMID:23986626

  14. Shoulder injuries in adolescent rugby players

    PubMed Central

    Hodhody, Ghazal; Mackenzie, Tanya A

    2016-01-01

    Background Rugby is a high-intensity contact sport, frequently causing shoulder injuries. Between the ages of 12 years to 18 years, academy and county level players are being selected for professional contracts, making this is a critical stage of their career. The present study aimed to describe the patterns of injury in adolescent rugby players with shoulder injuries. Methods Academy and county level rugby players in the target age group, over a 7-year period, were included in the present study. Data collected included the mechanism of injury, position and level of play, radiology and surgical findings, and recurrence rate at a minimum of 2 years post-surgery. Results One hundred and sixty-nine cases adhered to the inclusion criteria, with most cases involving two or more pathologies in the shoulder (54%). Forwards sustained more shoulder injuries than backs, incurring more labral injuries. By contrast, backs had a higher incidence of bony pathology. The mechanism of injury frequently correlated with player positions. There was a 21% injury recurrence rate, with forwards (7%) and higher level academy players (11%) most likely to suffer a recurrence. Conclusions Shoulder injury patterns in this important group of adolescent contact athletes are complex, with recurrence rates being higher than those in older rugby players. PMID:27583014

  15. Environmental analysis burial of offsite low-level waste at SRP

    NASA Astrophysics Data System (ADS)

    Poe, W. L.; Moyer, R. A.

    1980-12-01

    The environmental effects of receipt and burial of low level naval waste are assessed. This low level waste was sent to the NRC-licensed burial ground operated by Chem-Nuclear Systems, Inc., at Barnwell, South Carolina. The DOE announced that DOE-generated low level waste would no longer be buried at commercial waste burial sites. The SRP was selected to receive the Naval waste described in this analysis. Receipt and burial of these wastes will have a negligible effect on SRP's environment and increase only sightly the environmental effects of the SRP operations discussed in the EIS on SRP waste management operations. The environmental effects of burial of this waste at Chem-Nuclear Burial Ground or at the SRP Burial Ground are described in this environmental analysis to permit assessment of incremental effects caused by the decision to bury this Naval waste in the SRP Burial Ground rather than in the Barnwell Burial Ground. The radiological effects from burial of this waste in either the SRP or Chem-Nuclear Burial Ground are very small when compared to those from natural background radiation or to the annual population dose commitment from operation of SRP. The environmental effects of burial at SRP to dose commitments normally received by the population surrounding SRP are compared.

  16. Imaging Predictors of Improvement From a Motor Learning-Based Intervention for Children With Unilateral Cerebral Palsy.

    PubMed

    Schertz, Mitchell; Shiran, Shelly I; Myers, Vicki; Weinstein, Maya; Fattal-Valevski, Aviva; Artzi, Moran; Ben Bashat, Dafna; Gordon, Andrew M; Green, Dido

    2016-08-01

    Background Motor-learning interventions may improve hand function in children with unilateral cerebral palsy (UCP) but with inconsistent outcomes across participants. Objective To examine if pre-intervention brain imaging predicts benefit from bimanual intervention. Method Twenty children with UCP with Manual Ability Classification System levels I to III, aged 7-16 years, participated in an intensive bimanual intervention. Assessments included the Assisting Hand Assessment (AHA), Jebsen Taylor Test of Hand Function (JTTHF) and Children's Hand Experience Questionnaire (CHEQ) at baseline (T1), completion (T2) and 8-10 weeks post-intervention (T3). Imaging at baseline included conventional structural (radiological score), functional (fMRI) and diffusion tensor imaging (DTI). Results Improvements were seen across assessments; AHA (P = 0.04), JTTHF (P < .001) and CHEQ (P < 0.001). Radiological score significantly correlated with improvement at T2; AHA (r = .475) and CHEQ (r = .632), but negatively with improvement on unimanual measures at T3 (JTTFH r = -.514). fMRI showed negative correlations between contralesional brain activation when moving the affected hand and AHA improvements (T2: r = -.562, T3: r = -0.479). Fractional Anisotropy in the affected posterior limb of the internal capsule correlated negatively with increased bimanual use on CHEQ at T2 (r = -547) and AHA at T3 (r = -.656). Conclusions Children with greater structural, functional and connective brain damage showed enhanced responses to bimanual intervention. Baseline imaging may identify parameters predicting response to intervention in children with UCP. © The Author(s) 2015.

  17. Emergency radiology today between philosophy of science and the reality of "emergency care".

    PubMed

    Romano, L; Scaglione, M; Rotondo, A

    2006-03-01

    In the past 20 years, emergency care concept has substantially changed on a cultural point of view, going well beyond the boundaries of medical science. It is now a general understanding that the real enemy of the critical patient is time; thus, functional organisation and collocation of human and technological resources in the emergency department (ED) can help avoid the loss of human lives. This "cultural revolution" led to the creation and development of structural and organisational models (layouts) of EDs. Now, emergency radiology has a central role in ED organisation, and the radiologist, providing 24-h coverage in the emergency room, is crucial for the correct diagnostic approach and rapid management of trauma. If this is the cultural background to the "emergency care" concept, an overview of such care in our country shows great differences from a structural, technological and organisational point of view. The presence of the radiologist providing 24-h coverage in the emergency room is still uncommon in many EDs The qualification of emergency care must be sought by studying the needs of the population and by seeking qualified personnel with high professional skill levels. All this must be understood and pursued by politicians and health care managers whose aim should be to coordinate and check the measures and human resources applied to the system. This process necessarily involves rewarding those health care professionals who prove to be up to the job.

  18. Estimation of annual effective dose due to ingestion of natural radionuclides in foodstuffs and water at a proposed uranium mining site in India.

    PubMed

    Giri, Soma; Jha, V N; Singh, Gurdeep; Tripathi, R M

    2013-12-01

    To study the distribution of (210)Po, (226)Ra, (230)Th and U(nat) (naturally occurring radioisotopes of uranium [(234)U, (235)U and (238)U]) in food and water around the Bagjata uranium mining area in India. Radionuclides were analyzed in food samples of plant and animal origin after acid digestion. Intake and ingestion dose of the radionuclides were estimated. (210)Po, (226)Ra, (230)Th and U(nat) in all the dietary components ranged widely from < 0.2-36, < 0.02-1.58, < 0.01-2.8 and < 0.017-0.39 Bqkg(-1), respectively. The range of (226)Ra and U(nat) in water was < 3.5-206 and < 12.6-693 mBql(-1), respectively. The intake of radionuclides considering food and water was calculated to be 760 BqY(-1) while the ingestion dose was 601 μSvY(-1). The estimated doses reflect the natural background dose via route of ingestion, which is below the 1 mSvY(-1) limit set by the International Commission on Radiological Protection (ICRP). However, the doses are more than the dose constraint of 300 μSvY(-1) as suggested by the ICRP for members of the public for planned disposal of long-lived radioactive waste. The study confirms that current levels of radionuclides do not pose significant radiological risk to the local inhabitants, but they need close investigation in the near future.

  19. Serial serum alkaline phosphatase as an early biomarker for osteopenia of prematurity.

    PubMed

    Abdallah, Enas A A; Said, Reem N; Mosallam, Dalia S; Moawad, Eman M I; Kamal, Naglaa M; Fathallah, Mohammed G E-D

    2016-09-01

    Metabolic bone disease of prematurity is a condition characterized by reduction in bone mineral content (osteopenia). It is a problem faced by very low birth weight (VLBW) infants because of lack of fetal mineralization during the last trimester. Our aim was to assess serum alkaline phosphatase (ALP) level as an early biomarker for osteopenia in premature infants and to estimate an optimal cutoff value of serum ALP at which osteopenia is detected radiologically in premature newborns.This prospective study was conducted on a cohort of 120 newborn infants of both sex of ≤34 weeks' gestational age and <1500 g birth weight. Two blood samples, from each infant on at least 2 consecutive weeks, were reported for calcium, phosphorus, and ALP. Evidence of osteopenia was evaluated radiologically by performing wrist/knee x-ray.Sixteen infants (13.3%) had evidence of osteopenia in x-ray, whereas 104 infants (86.7%) were nonosteopenic and all the osteopenic infants were <1000-g birth weight. Birth weight and gestational age were significantly inversely related to serum ALP levels. Both samples showed statistically significantly higher mean ALP level in osteopenic than nonosteopenics (P < 0.001, and P < 0.001 respectively). There was no constant value of serum ALP related to radiologic evidence of osteopenia. However, the optimal cutoff value of serum ALP at which osteopenia is detected is 500 IU/L with 100% sensitivity and 80.77% specificity.High levels of ALP can be considered a reliable biomarker to predict the status of bone mineralization and the need for radiological evaluation in premature infants particularly those <1000-g birth weight and <32 weeks' gestation.

  20. Music during interventional radiological procedures, effect on sedation, pain and anxiety: a randomised controlled trial

    PubMed Central

    Kulkarni, S; Johnson, P C D; Kettles, S; Kasthuri, R S

    2012-01-01

    Objective : To assess the effects of playing patient-selected music during interventional procedures on (1) the doses of sedation and analgesia and (2) anxiety levels. Methods : Patients undergoing interventional radiological procedures were randomised to either the intervention (music) or the control (no music) group. Patients in the intervention group had music of their choice played via headphones during the procedure. The primary outcomes were reductions in the doses of drugs for sedation (midazolam) and analgesia (fentanyl). Anxiety levels were assessed both before and after the procedure using the validated State Anxiety Inventory. Mean pulse rate and average of mean blood pressures were also recorded before and during the procedures as surrogate indicators of anxiety levels. Results : 100 patients were randomised in a 1:1 ratio. There were 58 males and 42 females, with a mean age of 58 years. Sedation was required in 21 (42%) patients in the music group compared with 30 (60%) patients in the control group (p=0.046). The mean [standard deviation (SD)] midazolam dose was 2.1 mg (2.3 mg) in the control group and 1.3 mg (2.2 mg) in the music group (p=0.027). The mean (SD) fentanyl dose was 29 mg (40 mg) in the control group and 18 mg (34 mg) in the music group (p=0.055). There was no significant effect of music on the change from baseline in anxiety levels (p=0.74), pulse rate (p=0.56) or blood pressure (p=0.34). Conclusion : Sedation requirements are significantly reduced by playing self-selected music to the patient during interventional radiology procedures. By lowering sedation during interventional radiology, music makes the procedure safer. It also contributes favourably to the overall patient experience. PMID:22422386

  1. A dramatic, objective antiandrogen withdrawal response: case report and review of the literature.

    PubMed

    Lau, Yiu-Keung; Chadha, Manpreet K; Litwin, Alan; Trump, Donald L

    2008-11-05

    Antiandrogen withdrawal response is an increasingly recognized entity in patients with metastatic prostate cancer. To our knowledge, there have been no reports describing a durable radiologic improvement along with prostate-specific antigen (PSA) with discontinuation of the antiandrogen agent bicalutamide. We report a case in which a dramatic decline of serum PSA levels associated with a dramatic improvement in radiologic disease was achieved with bicalutamide discontinuation.

  2. Importance of establishing radiation protection culture in Radiology Department.

    PubMed

    Ploussi, Agapi; Efstathopoulos, Efstathios P

    2016-02-28

    The increased use of ionization radiation for diagnostic and therapeutic purposes, the rapid advances in computed tomography as well as the high radiation doses delivered by interventional procedures have raised serious safety and health concerns for both patients and medical staff and have necessitated the establishment of a radiation protection culture (RPC) in every Radiology Department. RPC is a newly introduced concept. The term culture describes the combination of attitudes, beliefs, practices and rules among the professionals, staff and patients regarding to radiation protection. Most of the time, the challenge is to improve rather than to build a RPC. The establishment of a RPC requires continuing education of the staff and professional, effective communication among stakeholders of all levels and implementation of quality assurance programs. The RPC creation is being driven from the highest level. Leadership, professionals and associate societies are recognized to play a vital role in the embedding and promotion of RPC in a Medical Unit. The establishment of a RPC enables the reduction of the radiation dose, enhances radiation risk awareness, minimizes unsafe practices, and improves the quality of a radiation protection program. The purpose of this review paper is to describe the role and highlight the importance of establishing a strong RPC in Radiology Departments with an emphasis on promoting RPC in the Interventional Radiology environment.

  3. [Severe lower gastrointestinal bleeding due to GIST tumor. Radiological embolization and surgery].

    PubMed

    Navas, Diana; Ríos, Antonio; Febrero, Beatriz; Rodríguez, José Manuel; Lloret, Francisco; Parrilla, Pascual

    2014-01-01

    Gastrointestinal stromal tumors (GIST) were identified only recently. These tumors usually have no symptoms, although they are localized, operable and curable. Although rare, if they are not diagnosed and treated early, they become very aggressive. The most common manifestation is gastrointestinal bleeding from mucosal erosion. Their presentation as severe lower gastrointestinal bleeding is exceptional. We report a patient with severe lower gastrointestinal bleeding stabilized by interventional radiology that subsequently required surgery for definitive care. Therapeutic use of radiological embolization is increasingly widespread in bleeding at various levels, achieving hemodynamic stabilization of patients. However, it must be kept in mind that, in cases of unknown etiology of lower gastrointestinal bleeding, possible causes must be investigated.

  4. Individual Radiological Protection Monitoring of Utrok Atoll Residents Based on Whole Body Counting of Cesium-137 (137Cs) and Plutonium Bioassay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamilton, T; Kehl, S; Brown, T

    2007-06-08

    This report contains individual radiological protection surveillance data developed during 2006 for adult members of a select group of families living on Utrok Atoll. These Group I volunteers all underwent a whole-body count to determine levels of internally deposited cesium-137 ({sup 137}Cs) and supplied a bioassay sample for analysis of plutonium isotopes. Measurement data were obtained and the results compared with an equivalent set of measurement data for {sup 137}Cs and plutonium isotopes from a second group of adult volunteers (Group II) who were long-term residents of Utrok Atoll. For the purposes of this comparison, Group II volunteers were consideredmore » representative of the general population on Utrok Atoll. The general aim of the study was to determine residual systemic burdens of fallout radionuclides in each volunteer group, develop data in response to addressing some specific concerns about the preferential uptake and potential health consequences of residual fallout radionuclides in Group I volunteers, and generally provide some perspective on the significance of radiation doses delivered to volunteers (and the general Utrok Atoll resident population) in terms of radiological protection standards and health risks. Based on dose estimates from measurements of internally deposited {sup 137}Cs and plutonium isotopes, the data and information developed in this report clearly show that neither volunteer group has acquired levels of internally deposited fallout radionuclides specific to nuclear weapons testing in the Marshall Islands that are likely to have any consequence on human health. Moreover, the dose estimates are well below radiological protection standards as prescribed by U.S. regulators and international agencies, and are very small when compared to doses from natural sources of radiation in the Marshall Islands and the threshold where radiation health effects could be either medically diagnosed in an individual or epidemiologically discerned in a group of people. In general, the results from the whole-body counting measurements of 137Cs are consistent with our knowledge that a key pathway for exposure to residual fallout contamination on Utrok Atoll is low-level chronic uptake of {sup 137}Cs from the consumption of locally grown produce (Robison et al., 1999). The error-weighted, average body burden of {sup 137}Cs measured in Group I and Group II volunteers was 0.31 kBq and 0.62 kBq, respectively. The associated average, annual committed effective dose equivalent (CEDE) delivered to Group I and Group II volunteers from {sup 137}Cs during the year of measurement was 2.1 and 4.0 mrem. For comparative purposes, the annual dose limit for members of the public as recommended by the National Council on Radiation Protection and Measurements (NCRP) and the International Commission on Radiological Protection (ICRP) is 100 mrem. Consequently, specific concerns about elevated levels of {sup 137}Cs uptake and higher risks from radiation exposure to Group I volunteers would be considered unfounded. Moreover, the urinary excretion of plutonium-239 ({sup 239}Pu) from Group I and Group II volunteers is statistically indistinguishable. In this case, the error-weighted, average urinary excretion of {sup 239}Pu from Group I volunteers of 0.10 {mu}Bq per 24-h void with a range between -0.01 and 0.23 {mu}Bq per 24-h void compares with an error-weighted average from Group II volunteers of 0.11 {mu}Bq per 24-h void with a range between -0.20 and 0.47 {mu}Bq per 24-h void. The range in urinary excretion of {sup 239}Pu from Utrok Atoll residents is very similar to that observed for other population groups in the Marshall Islands (Bogen et al., 2006; Hamilton et al., 2006a; 2006b; 2006c, 2007a; 2007b; 2007c) and is generally considered representative of worldwide background.« less

  5. Variation of annual effective dose due to radon level in indoor air in Marwar region of Rajasthan, India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rani, Asha, E-mail: ashasachdeva78@gmail.com; Mittal, Sudhir, E-mail: sudhirmittal03@gmail.com; Mehra, Rohit

    In the present work, indoor radon and thoron measurements have been carried out from different locations of Jodhpur and Nagaur districts of Northern Rajasthan, India using RAD7, a solid state alpha detector. The radon and thoron concentration in indoor air varies from 8.75 to 61.25 Bq m{sup −3} and 32.7 to 147.2 Bq m{sup −3} with the mean value of 32 and 73 Bq m{sup −3} respectively. The observed indoor radon concentration values are well below the action level recommended by International Commission on Radiological Protection (200-300 Bq m{sup −3}) and Environmental Protection Agency (148 Bq m{sup −3}). The surveymore » reveals that the thoron concentration values in the indoor air are well within the International Commission on Radiological Protection (2005). The calculated total annual effective dose due to radon level in indoor air varies from 0.22 to 1.54 mSv y{sup −1} with the mean value of 0.81 mSv y{sup −1} which is less than even the lower limit of action level 3-10 mSv y{sup −1} recommended by International Commission on Radiological Protection (2005)« less

  6. Cost analysis of equipment failure of a radiology department and possible choices about maintenance.

    PubMed

    Grisi, Guido; Dalla Palma, Ludovico; Rimondini, Allesandra; Palmolungo, Chiara; Cuttin Zernich, Roberto; Pozzi Mucelli, Roberto

    2002-01-01

    Our aim was to evaluate the economic impact of equipment failures in a radiology department with a view to guiding maintenance policy decisions. We assessed the negative economic impact caused by the interruption of activity of a radiodiagnostics section due to equipment failure, taking into account: the effects occurring during the first day of equipment down-time (assuming that the equipment failure occurs in the middle of the shift) and the effects during the following days until the repair of the failure; the effects occurring in the short- and long-term. To exemplify the negative impact of inactivity due to equipment failure, we chose three radiology sections with different levels of technological and operational complexity (chest radiology, gastrointestinal radiology and remote-controlled diagnostics). For each, we evaluated the loss of contribution margin and the idle capacity costs (short- and long-term impact). The negative economic effects were: for thoracic radiology, 496,77 Euro in the first day, and 30,99 Euro from the second day onwards; for gastrointestinal radiology, 526,40 Euro for the first day, and 730,39 Euro from the second day onwards; for remote-controlled diagnostics, 786,25 Euro for the first day, and 927,67 Euro from the second days onwards. Our results indicate that the level of idle capacity costs (mainly equipment and staff) increases with the complexity of the equipment, whereas the contribution margin appears to fluctuate, because the charges are state-imposed and do not vary with the complexity of equipment. Moreover, our analysis shows that if the workload of a broken machine can easily be assigned to an additional shift using another machine, losses are considerably reduced from the second day onwards. Once the negative economic impact of equipment failures has been evaluated, the second step is to choose the best kind of maintenance. A sound calculation of the economic impact of equipment failures is very useful for guiding the head of department and the hospital manager in deciding whether to purchase maintenance services (or a long-term guarantee) from the equipment manufacturer, to set up an auxiliary centre for maintenance and repair, or to purchase a third-party maintenance contract.

  7. Degenerative lumbar spinal stenosis: correlation with Oswestry Disability Index and MR imaging.

    PubMed

    Sirvanci, Mustafa; Bhatia, Mona; Ganiyusufoglu, Kursat Ali; Duran, Cihan; Tezer, Mehmet; Ozturk, Cagatay; Aydogan, Mehmet; Hamzaoglu, Azmi

    2008-05-01

    Because neither the degree of constriction of the spinal canal considered to be symptomatic for lumbar spinal stenosis nor the relationship between the clinical appearance and the degree of a radiologically verified constriction is clear, a correlation of patient's disability level and radiographic constriction of the lumbar spinal canal is of interest. The aim of this study was to establish a relationship between the degree of radiologically established anatomical stenosis and the severity of self-assessed Oswestry Disability Index in patients undergoing surgery for degenerative lumbar spinal stenosis. Sixty-three consecutive patients with degenerative lumbar spinal stenosis who were scheduled for elective surgery were enrolled in the study. All patients underwent preoperative magnetic resonance imaging and completed a self-assessment Oswestry Disability Index questionnaire. Quantitative image evaluation for lumbar spinal stenosis included the dural sac cross-sectional area, and qualitative evaluation of the lateral recess and foraminal stenosis were also performed. Every patient subsequently answered the national translation of the Oswestry Disability Index questionnaire and the percentage disability was calculated. Statistical analysis of the data was performed to seek a relationship between radiological stenosis and percentage disability recorded by the Oswestry Disability Index. Upon radiological assessment, 27 of the 63 patients evaluated had severe and 33 patients had moderate central dural sac stenosis; 11 had grade 3 and 27 had grade 2 nerve root compromise in the lateral recess; 22 had grade 3 and 37 had grade 2 foraminal stenosis. On the basis of the percentage disability score, of the 63 patients, 10 patients demonstrated mild disability, 13 patients moderate disability, 25 patients severe disability, 12 patients were crippled and three patients were bedridden. Radiologically, eight patients with severe central stenosis and nine patients with moderate lateral stenosis demonstrated only minimal disability on percentage Oswestry Disability Index scores. Statistical evaluation of central and lateral radiological stenosis versus Oswestry Disability Index percentage scores showed no significant correlation. In conclusion, lumbar spinal stenosis remains a clinico-radiological syndrome, and both the clinical picture and the magnetic resonance imaging findings are important when evaluating and discussing surgery with patients having this diagnosis. MR imaging has to be used to determine the levels to be decompressed.

  8. Relationship between anxiety level and radiological investigation. Comparison among different diagnostic imaging exams in a prospective single-center study.

    PubMed

    Lo Re, Giuseppe; De Luca, Rossella; Muscarneri, Filippa; Dorangricchia, Patrizia; Picone, Dario; Vernuccio, Federica; Salerno, Sergio; La Tona, Giuseppe; Pinto, Antonio; Midiri, Massimo; Russo, Antonio; Lagalla, Roberto; Cicero, Giuseppe

    2016-10-01

    Every patient could feel anxious when he waits in a radiological department to undergo diagnostic exams. The aim of our study is to evaluate the impact of the radiological exams on patient anxiety. We evaluated 343 patients (mean age 54.83 years) who underwent different types of diagnostic exams in the Department of Diagnostic Imaging at our Hospital from April 2013 to August 2014. We administered to patients the State and Trait Anxiety Inventory Test, which detected with high sensitivity both state anxiety and trait anxiety. A team of clinical psychologists and radiologists evaluated the scores obtained. 83 out of 343 patients were excluded because refused to file the questionnaire. 31 % of the patients were submitted to MR, 18 % to breast imaging, 10 % to X-ray, 22 % Computer Tomography and 19 % to ultrasound, as previously described. 41 % of patients were submitted to the examination because of an oncologic disease, while 59 % because of non-oncological disease. Therefore, it was found that high levels of anxiety were present in most (about 91 %) of the patients and the scores varied according to the imaging examination and to the examination's reason: anxiety level was higher in non-oncological patients (54 %) and in patients waiting to undergo to MRI exams (29 %). Our data suggest that the diagnostic exams are stressful events for the patient, also in non-oncological patients. So, it is important to adequate the radiological staff to receive the patient, to inform him and perform exams with emotive involvement with a targeted education. Also, further studies are needed to evaluate the anxiety level and the quality of the images, because the anxiety can result in a somatic disorder with hyperactivity of the autonomic nervous system which may affect the patient's physical examination, causing problems in the evaluation of radiological images making to non-cooperative patient. MRI imaging is the examination that more of all led to an anxious state of patients but the main stressor is not related to the type of diagnostic examination, but to the uncertainty of the diagnosis, therapy and prognosis.

  9. A Planning Tool for Estimating Waste Generated by a Radiological Incident and Subsequent Decontamination Efforts - 13569

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boe, Timothy; Lemieux, Paul; Schultheisz, Daniel

    2013-07-01

    Management of debris and waste from a wide-area radiological incident would probably constitute a significant percentage of the total remediation cost and effort. The U.S. Environmental Protection Agency's (EPA's) Waste Estimation Support Tool (WEST) is a unique planning tool for estimating the potential volume and radioactivity levels of waste generated by a radiological incident and subsequent decontamination efforts. The WEST was developed to support planners and decision makers by generating a first-order estimate of the quantity and characteristics of waste resulting from a radiological incident. The tool then allows the user to evaluate the impact of various decontamination/demolition strategies onmore » the waste types and volumes generated. WEST consists of a suite of standalone applications and Esri{sup R} ArcGIS{sup R} scripts for rapidly estimating waste inventories and levels of radioactivity generated from a radiological contamination incident as a function of user-defined decontamination and demolition approaches. WEST accepts Geographic Information System (GIS) shape-files defining contaminated areas and extent of contamination. Building stock information, including square footage, building counts, and building composition estimates are then generated using the Federal Emergency Management Agency's (FEMA's) Hazus{sup R}-MH software. WEST then identifies outdoor surfaces based on the application of pattern recognition to overhead aerial imagery. The results from the GIS calculations are then fed into a Microsoft Excel{sup R} 2007 spreadsheet with a custom graphical user interface where the user can examine the impact of various decontamination/demolition scenarios on the quantity, characteristics, and residual radioactivity of the resulting waste streams. (authors)« less

  10. 2016 Annual Inspection and Radiological Survey Results for the Piqua, Ohio, Decommissioned Reactor Site, July 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zimmerman, Brian; Miller, Michele

    This report presents the findings of the annual inspection and radiological survey of the Piqua, Ohio, Decommissioned Reactor Site (site). The decommissioned nuclear power demonstration facility was inspected and surveyed on April 15, 2016. The site, located on the east bank of the Great Miami River in Piqua, Ohio, was in fair physical condition. There is no requirement for a follow-up inspection, partly because City of Piqua (City) personnel participated in a March 2016 meeting to address reoccurring safety concerns. Radiological survey results from 104 locations revealed no removable contamination. One direct beta activity reading in a floor drain onmore » the 56-foot level (1674 disintegrations per minute [dpm]/100 square centimeters [cm2]) exceeded the minimum detectable activity (MDA). Beta activity has been detected in the past at this floor drain. The reading was well below the action level of 5000 dpm/100 cm2.« less

  11. The optimisation of occupational potential exposures - preliminary considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crouail, P.; Guimaraes, L.

    1995-03-01

    One of the major innovation brought about the ICRP 60 recommendations and emphasized by the ICRP 64 publication, is the introduction of the concept of potential exposures into the system of radiological protection. Potential exposures are characterized by {open_quotes}probability of occurrence lesser than unity{close_quotes} and {open_quotes}radiological risks exceeding normal levels{close_quotes} where normal must be interpreted as not exceeding the planned routine exposures. It is then necessary to develop consensual methods to look for and choose the optimum scenarios (i.e. those for which probability of events and possible consequences have been reduced as low as reasonably achievable). Moreover, the boundaries formore » the unacceptable levels of risks for workers should be defined, as well as reasonable risk indicators. The aim of this paper is to discuss the actual changes in the field of occupational radiological protection, induced by the potential exposure concept with particular emphasize on the optimization of protection.« less

  12. Online Radiology Reporting with Peer Review as a Learning and Feedback Tool in Radiology; Implementation, Validity, and Student Impressions.

    PubMed

    McEvoy, Fintan J; Shen, Nicholas W; Nielsen, Dorte H; Buelund, Lene E; Holm, Peter

    2017-02-01

    Communicating radiological reports to peers has pedagogical value. Students may be uneasy with the process due to a lack of communication and peer review skills or to their failure to see value in the process. We describe a communication exercise with peer review in an undergraduate veterinary radiology course. The computer code used to manage the course and deliver images online is reported, and we provide links to the executable files. We tested to see if undergraduate peer review of radiological reports has validity and describe student impressions of the learning process. Peer review scores for student-generated radiological reports were compared to scores obtained in the summative multiple choice (MCQ) examination for the course. Student satisfaction was measured using a bespoke questionnaire. There was a weak positive correlation (Pearson correlation coefficient = 0.32, p < 0.01) between peer review scores students received and the student scores obtained in the MCQ examination. The difference in peer review scores received by students grouped according to their level of course performance (high vs. low) was statistically significant (p < 0.05). No correlation was found between peer review scores awarded by the students and the scores they obtained in the MCQ examination (Pearson correlation coefficient = 0.17, p = 0.14). In conclusion, we have created a realistic radiology imaging exercise with readily available software. The peer review scores are valid in that to a limited degree they reflect student future performance in an examination. Students valued the process of learning to communicate radiological findings but do not fully appreciated the value of peer review.

  13. Tritium concentrations in bees and honey at Los Alamos National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fresquez, P.R.; Armstrong, D.R.; Salazar, J.G.

    Los Alamos National Laboratory (LANL) has maintained a network of honey bee colonies at LANL, perimeter (Los Alamos townsite and White Rock/Pajarito Acres) and regional (background) areas for over 15 years; the main objective of this honey bee network was to help determine the bioavailability of certain radionuclides in the environment. Of all the radionuclides studied ({sup 3}H, {sup 57}Co, {sup 7}Be, {sup 22}Na, {sup 54}Mn, {sup 83}Rb, {sup 137}Cs, {sup 238}Pu, {sup 239}Pu, {sup 90}Sr and total U), tritium was consistently detected in bees and was most readily transferred to the honey. In fact, honey collected from hives locatedmore » at TA-21, TA-33, TA-50, TA-53, and TA-54 and from White Rock/Pajarito Acres contained significantly higher concentrations of {sup 3}H than regional background hives. Based on the average concentration of all radionuclides measured over the years, the effective dose equivalent (EDE) from consuming 5 kg (11 lb) of honey collected from Los Alamos (townsite) and White Rock/Pajarito Acres, after regional background has been subtracted, was 0.0186 ({+-}0.0507) and 0.0016 ({+-}0.0010) mrem/yr, respectively. The highest EDE, based on the mean + 2SD (95% confidence level), was 0.1200 mrem/y; this was <0.2% of the International Commission on Radiological Protection permissible dose limit of 100 mrem/yr from all pathways.« less

  14. [Radiologic Presentation in Subspine Impingement and Correlation with Intraarticular Impingement in the Hip].

    PubMed

    Krüger, David R; Schütz, Michael; Perka, Carsten; Schröder, Jörg

    2017-08-01

    Background Besides the known intraarticular femoroacetabular impingement (FAI), recently forms of extra-articular impingement of the hip have been increasingly recognized. Recent studies have described an extra-articular impingement between a distal extension of the anterior inferior iliac spine (AIIS) and the femoral neck (AIIS or subspine impingement). Evidently, an association between this subspine impingement and an intraarticular FAI seems to exist. Little is known about the incidence of this impingement type and the value of its radiological diagnostics. The aim of this study was therefore to evaluate the correlation of a subspine impingement with intraarticular femoroacetabular impingement and radiological criteria of subspine impingement. Material and Methods In 2013 arthroscopic correction of intra-articular femoroacetabular impingement was performed in 80 cases. This collective was evaluated for simultaneous intraoperative findings of subspine impingement. In addition, the patients were evaluated for radiological signs of subspine impingement in conventional X-ray. A projection of the AIIS either below the acetabular sourcil or the anterior acetabular rim in an AP pelvis X-ray was considered as a radiological sign of low AIIS formation. These radiological findings were compared with the presence of intraoperative signs for subspine impingement, which are defined as a combination of focal capsule synovitis, labral ecchymosis close to the AIIS and a decreased offset between the acetabular rim and the AIIS. The specificity and sensitivity of the pre-operative radiological signs were calculated. Results A subspine impingement was found in 17 cases (21 %, 3 female, 14 male, mean age 28 years). A projection of the AIIS caudal to the acetabular sourcil in the AP pelvis X-ray was represented in 15 of the 17 cases detected (sensitivity 0.90, specificity 0.88). A projection below the anterior glenoid rim was detectable in 2 cases with symptomatic AIIS impingement (sensitivity 0.12, specificity 1). Conclusion A relevant proportion of patients with intraarticular FAI showed intraoperative signs for an additive extraarticular AIIS impingement. Preoperative pelvic X-rays are helpful with a sensitivity of 90 % in detecting the presence of a distal extension of the AIIS in FAI patients. Evaluation of the preoperative AP pelvis x-ray should include the projection of the AIIS. We recommend evaluation for subspine impingement during routine arthroscopy. Georg Thieme Verlag KG Stuttgart · New York.

  15. Emergency radiology and mass casualty incidents-report of a mass casualty incident at a level 1 trauma center.

    PubMed

    Bolster, Ferdia; Linnau, Ken; Mitchell, Steve; Roberge, Eric; Nguyen, Quynh; Robinson, Jeffrey; Lehnert, Bruce; Gross, Joel

    2017-02-01

    The aims of this article are to describe the events of a recent mass casualty incident (MCI) at our level 1 trauma center and to describe the radiology response to the event. We also describe the findings and recommendations of our radiology department after-action review. An MCI activation was triggered after an amphibious military vehicle, repurposed for tourist activities, carrying 37 passengers, collided with a charter bus carrying 45 passengers on a busy highway bridge in Seattle, WA, USA. There were 4 deaths at the scene, and 51 patients were transferred to local hospitals following prehospital scene triage. Nineteen patients were transferred to our level 1 trauma center. Eighteen casualties arrived within 72 min. Sixteen arrived within 1 h of the first patient arrival, and 1 casualty was transferred 3 h later having initially been assessed at another hospital. Eighteen casualties (94.7 %) underwent diagnostic imaging in the emergency department. Of these 18 casualties, 15 had a trauma series (portable chest x-ray and x-ray of pelvis). Whole-body trauma computed tomography scans (WBCT) were performed on 15 casualties (78.9 %), 12 were immediate and performed during the initial active phase of the MCI, and 3 WBCTs were delayed. The initial 12 WBCTs were completed in 101 min. The mean number of radiographic studies performed per patient was 3 (range 1-8), and the total number of injuries detected was 88. The surge in imaging requirements during an MCI can be significant and exceed normal operating capacity. This report of our radiology experience during a recent MCI and subsequent after-action review serves to provide an example of how radiology capacity and workflow functioned during an MCI, in order to provide emergency radiologists and response planners with practical recommendations for implementation in the event of a future MCI.

  16. User acceptance of a picture archiving and communication system (PACS) in a Saudi Arabian hospital radiology department

    PubMed Central

    2012-01-01

    Background Compared with the increasingly widespread use of picture archiving and communication systems (PACSs), knowledge concerning users’ acceptance of such systems is limited. Knowledge of acceptance is needed given the large (and growing) financial investment associated with the implementation of PACSs, and because the level of user acceptance influences the degree to which the benefits of the systems for healthcare can be realized. Methods A Technology Acceptance Model (TAM) was used to assess the level of acceptance of the host PACS by staff in the radiology department at King Abdulaziz Medical City (KAMC), Riyadh, Saudi Arabia. A questionnaire survey of 89 PACS users was employed to obtain data regarding user characteristics, perceived usefulness (PU) (6 items), perceived ease of use (PEU) (4 items), a change construct (4 items), and a behavior (acceptance) construct (9 items). Respondents graded each item in each construct using five-point likert scales. Results Surveyed users reported high levels of PU (4.33/5), PEU (4.15/5), change (4.26/5), and acceptance (3.86/5). The three constructs of PU, PEU, and change explained 41 % of the variation in PACS user acceptance. PU was the most important predictor, explaining 38 % of the variation on its own. The most important single item in the explanatory constructs was that users found PACS to have improved the quality of their work in providing better patient care. Technologists had lower acceptance ratings than did clinicians/radiologists, but no influence on acceptance level was found due to gender, age, or length of experience using the PACS. Although not directly measured, there appeared to be no cultural influence on either the level of acceptance or its determinants. Conclusions User acceptance must be considered when an organization implements a PACS, in order to enhance its successful adoption. Health organizations should adopt a PACS that offers all required functions and which is likely to generate high PU on the part of its users, rather than a system that is easy to use. Training/familiarization programs should aim at establishing high levels of PU in all users, particularly technologists. Health organizations are advised to measure all the factors that influence the acceptance of a PACS by their staff, in order to optimize the productivity of the system and realize the potential benefits to the greatest extent possible. PMID:22640490

  17. Are we failing to communicate? Internet-based patient education materials and radiation safety.

    PubMed

    Hansberry, David R; Ramchand, Tekchand; Patel, Shyam; Kraus, Carl; Jung, Jin; Agarwal, Nitin; Gonzales, Sharon F; Baker, Stephen R

    2014-09-01

    Patients frequently turn to the Internet when seeking answers to healthcare related inquiries including questions about the effects of radiation when undergoing radiologic studies. We investigate the readability of online patient education materials concerning radiation safety from multiple Internet resources. Patient education material regarding radiation safety was downloaded from 8 different websites encompassing: (1) the Centers for Disease Control and Prevention, (2) the Environmental Protection Agency, (3) the European Society of Radiology, (4) the Food and Drug Administration, (5) the Mayo Clinic, (6) MedlinePlus, (7) the Nuclear Regulatory Commission, and (8) the Society of Pediatric Radiology. From these 8 resources, a total of 45 articles were analyzed for their level of readability using 10 different readability scales. The 45 articles had a level of readability ranging from 9.4 to the 17.2 grade level. Only 3/45 (6.7%) were written below the 10th grade level. No statistical difference was seen between the readability level of the 8 different websites. All 45 articles from all 8 websites failed to meet the recommendations set forth by the National Institutes of Health and American Medical Association that patient education resources be written between the 3rd and 7th grade level. Rewriting the patient education resources on radiation safety from each of these 8 websites would help many consumers of healthcare information adequately comprehend such material. Copyright © 2014. Published by Elsevier Ireland Ltd.

  18. Early radiological and functional outcomes for a cementless press-fit design modular femoral stem revision system.

    PubMed

    Hancock, Douglas S; Sharplin, Paul K; Larsen, Peter D; Phillips, Fredrick Ts

    2018-05-01

    To assess early radiological and functional outcomes of revision hip surgery with a cementless press-fit design femoral stem. A retrospective review of 48 consecutive revision total hip replacements using the RECLAIM revision hip system, between October 2012 and August 2015. Radiographic assessment was undertaken with serial anteroposterior (AP) X-rays of the pelvis. Risk factors for subsidence were evaluated. Prospective clinical follow up was performed on 21 patients to assess functional outcomes. Mean stem subsidence was 1.1 mm (95% confidence interval[CI]: 0.63-1.57). Median follow up of 12 months. An inverse relationship was observed between level of subsidence and femoral stem diameter r = -0.45, p = 0.001. Subsidence at the time of follow-up assessment was correlated with initial subsidence (correlation coefficient rho 0.69, p = 0.001). The mean Merle d'Aubigne score at the latest follow up was 14.2 (range 8-17). The mean OHS was 34.1 (range 15-48). Early radiological and functional outcomes for the RECLAIM revision system showed very low levels of subsidence and good functional outcomes. There was an association with smaller diameter femoral stems and greater levels of subsidence.

  19. 226Ra, 232Th and 40K contents in water samples in part of central deserts in Iran and their potential radiological risk to human population

    PubMed Central

    2014-01-01

    Background The radiological quality of 226Ra, 232Th and 40K in some samples of water resources collected in Anarak-Khour a desertic area, Iran has been measured by direct gamma ray spectroscopy using high purity germanium detector in this paper. Result The concentration ranged from ≤0.5 to 9701 mBq/L for 226Ra; ≤0.2 to 28215 mBq/L for 232Th and < MDA to 10332 mBq/L for 40K. The radium equivalent activity was well below the defined limit of 370Bq/L. The calculated external hazard indices were found to be less than 1 which shows a low dose. Conclusion These results can be contributed to the database of this area because it may be used as disposal sites of nuclear waste in future. PMID:24883192

  20. Infection by Streptococcus pneumoniae in children with or without radiologically confirmed pneumonia.

    PubMed

    Andrade, Dafne C; Borges, Igor C; Vilas-Boas, Ana Luísa; Fontoura, Maria S H; Araújo-Neto, César A; Andrade, Sandra C; Brim, Rosa V; Meinke, Andreas; Barral, Aldina; Ruuskanen, Olli; Käyhty, Helena; Nascimento-Carvalho, Cristiana M

    Community-acquired pneumonia is an important cause of morbidity in childhood, but the detection of its causative agent remains a diagnostic challenge. The authors aimed to evaluate the role of the chest radiograph to identify cases of community-aquired pneumonia caused by typical bacteria. The frequency of infection by Streptococcus pneumoniae, Haemophilus influenzae, and Moraxella catarrhalis was compared in non-hospitalized children with clinical diagnosis of community acquired pneumonia aged 2-59 months with or without radiological confirmation (n=249 and 366, respectively). Infection by S. pneumoniae was diagnosed by the detection of a serological response against at least one of eight pneumococcal proteins (defined as an increase ≥2-fold in the IgG levels against Ply, CbpA, PspA1 and PspA2, PhtD, StkP-C, and PcsB-N, or an increase ≥1.5-fold against PcpA). Infection by H. influenzae and M. catarrhalis was defined as an increase ≥2-fold on the levels of microbe-specific IgG. Children with radiologically confirmed pneumonia had higher rates of infection by S. pneumoniae. The presence of pneumococcal infection increased the odds of having radiologically confirmed pneumonia by 2.8 times (95% CI: 1.8-4.3). The negative predictive value of the normal chest radiograph for infection by S. pneumoniae was 86.3% (95% CI: 82.4-89.7%). There was no difference on the rates of infection by H. influenzae and M. catarrhalis between children with community-acquired pneumonia with and without radiological confirmation. Among children with clinical diagnosis of community-acquired pneumonia submitted to chest radiograph, those with radiologically confirmed pneumonia present a higher rate of infection by S. pneumoniae when compared with those with a normal chest radiograph. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  1. Tritium in well waters, streams and atomic lakes in the East Kazakhstan Oblast of the Semipalatinsk Nuclear Test Site.

    PubMed

    Mitchell, Peter I; Vintró, Luis León; Omarova, Aigul; Burkitbayev, Mukhambetkali; Nápoles, Humberto Jiménez; Priest, Nicholas D

    2005-06-01

    The concentration of tritium has been determined in well waters, streams and atomic lakes in the Sarzhal, Tel'kem, Balapan and Degelen Mountains areas of the Semipalatinsk Test Site. The data show that levels of tritium in domestic well waters within the settlement of Sarzhal are extremely low at the present time with a median value of 4.4 Bq dm(-3) (95% confidence interval:4.1-4.7 Bq dm(-3)). These levels are only marginally above the background tritium content in surface waters globally. Levels in the atomic craters at Tel'kem 1 and Tel'kem 2 are between one and two orders of magnitude higher, while the level in Lake Balapan is approximately 12,600 Bq dm(-3). Significantly, levels in streams and test-tunnel waters sourced in the Degelen Mountains, the site of approximately 215 underground nuclear tests, are a further order of magnitude higher, being in the range 133,000--235,500 Bq dm(-3). No evidence was adduced which indicates that domestic wells in Sarzhal are contaminated by tritium-rich waters sourced in the Degelen massif, suggesting that the latter are not connected hydrologically to the near-surface groundwater recharging the Sarzhal wells. Annual doses to humans arising from the ingestion of tritium in these well waters are very low at the present time and are of no radiological significance.

  2. Evaluating the Impact of a Canadian National Anatomy and Radiology Contouring Boot Camp for Radiation Oncology Residents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaswal, Jasbir; D'Souza, Leah; Johnson, Marjorie

    Background: Radiation therapy treatment planning has advanced over the past 2 decades, with increased emphasis on 3-dimensional imaging for target and organ-at-risk (OAR) delineation. Recent studies suggest a need for improved resident instruction in this area. We developed and evaluated an intensive national educational course (“boot camp”) designed to provide dedicated instruction in site-specific anatomy, radiology, and contouring using a multidisciplinary (MDT) approach. Methods: The anatomy and radiology contouring (ARC) boot camp was modeled after prior single-institution pilot studies and a needs-assessment survey. The boot camp incorporated joint lectures from radiation oncologists, anatomists, radiologists, and surgeons, with hands-on contouring instructionmore » and small group interactive seminars using cadaveric prosections and correlative axial radiographs. Outcomes were evaluated using pretesting and posttesting, including anatomy/radiology multiple-choice questions (MCQ), timed contouring sessions (evaluated relative to a gold standard using Dice similarity metrics), and qualitative questions on satisfaction and perceived effectiveness. Analyses of pretest versus posttest scores were performed using nonparametric paired testing. Results: Twenty-nine radiation oncology residents from 10 Canadian universities participated. As part of their current training, 29%, 75%, and 21% receive anatomy, radiology, and contouring instruction, respectively. On posttest scores, the MCQ knowledge scores improved significantly (pretest mean 60% vs posttest mean 80%, P<.001). Across all contoured structures, there was a 0.20 median improvement in students' average Dice score (P<.001). For individual structures, significant Dice improvements occurred in 10 structures. Residents self-reported an improved ability to contour OARs and interpret radiographs in all anatomic sites, 92% of students found the MDT format effective for their learning, and 93% found the boot camp more effective than educational sessions at their own institutions. All of the residents (100%) would recommend this course to others. Conclusions: The ARC boot camp is an effective intervention for improving radiation oncology residents' knowledge and understanding of anatomy and radiology in addition to enhancing their confidence and accuracy in contouring.« less

  3. Bikini scientific resurvey. Volume II. Report of the technical director. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1947-12-01

    Contents: Island and Reef Geology; Submarine Geology; Drilling Operations; Radiobiology Studies; Reef and Lagoon Fishes; Pelagic Fishes; Taxonomy and Teratology of Fishes; Invertebrate Embryology; Vertebrate Embryology; Reef and Lagoon Algae; Chemical Effects of Organisms Upon Sea Water; The Insect Population; Marine Invertebrates; Land Animals; Plankton Studies; Counter-Room Activities; Radiochemical Analyses; Soils Chemistry; Low-Level Radiation Studies; Army Engineering Studies; Aerological Data; Bacteriological Investigations; Radiological Safety; Radiological Health; Technical Director's Summary.

  4. A dramatic, objective antiandrogen withdrawal response: case report and review of the literature

    PubMed Central

    Lau, Yiu-Keung; Chadha, Manpreet K; Litwin, Alan; Trump, Donald L

    2008-01-01

    Antiandrogen withdrawal response is an increasingly recognized entity in patients with metastatic prostate cancer. To our knowledge, there have been no reports describing a durable radiologic improvement along with prostate-specific antigen (PSA) with discontinuation of the antiandrogen agent bicalutamide. We report a case in which a dramatic decline of serum PSA levels associated with a dramatic improvement in radiologic disease was achieved with bicalutamide discontinuation. PMID:18986533

  5. Patients' satisfaction towards radiological service and associated factors in Hawassa University Teaching and referral hospital, Southern Ethiopia.

    PubMed

    Mulisa, Teshome; Tessema, Fasil; Merga, Hailu

    2017-06-26

    Patient satisfaction, one of the main components of quality of care, is a crucial phenomenon for the overall health care delivery system. Even though a number of studies have been conducted about patient satisfaction in different health services, studies in radiology services are flimsy in Ethiopia. This study aimed at assessing patient satisfaction towards radiological service and associated factors in Hawassa University Teaching and Referral hospital. An institution based cross-sectional study was conducted among 321 adult patients presented for radiological service in the study area using stratified sampling technique. Patient satisfaction was measured using SERVQUAL (Service Quality) tool that consisted of seven items: accessibility, quality of radiological service, courtesy of radiology staff, existence of good communication with service provider and desk worker, physical environment and privacy technique. Exit interviews of patients were conducted using a structured and pretested questionnaire. Data was collected by three grade ten completed trained data collectors from May 12 to May 28, 2016. Multiple logistic regressions were used to identify independent factors associated with patient satisfaction on radiological services using SPSS version 21. The overall patient satisfaction towards radiological service was 71.6%. Satisfaction to accessibility of the service was 84.5% while it was 80.6% to courtesy of the staff. Similarly, 81.6% reported satisfied with quality of the service and 59.4% and 71% of reported satisfied with physical environment and radiological service provider respectively. On the other hand, 99.7% of the respondents were dissatisfied with privacy of the service. The study revealed that patients who attended primary school (AOR = 0.317, 95% CI: 0.11-0.88), unemployed patients (AOR = 0.067, 95% CI: 0.007-0.622) and patients who had short waiting time to enter into examination room less than one hour (AOR = 4.12, 95% CI: 1.4-11.62) were factors associated with patients satisfaction. This study found that majority of respondents was satisfied with the radiological services. Respondent's education level, occupation as well as duration of time taken to enter into examination room were important factors influencing the satisfaction condition. Hence, concerted effort is needed to constantly improve on patient satisfaction to better radiology returns arising from improved patient patronage. It is recommended to give great care and attention to clients during radiological examination procedure and also suggested that the department should decrease time taken to enter into examination room. On the other hand, the reasons behind more educated clients were less satisfied with radiologic service than more educated respondents need further investigation.

  6. Evaluation of odontological assistance to soldiers going on a mission, and prognostication of their odontological problems.

    PubMed

    Kelbauskiene, Nijole; Kelbauskas, Eduardas; Nedzelskiene, Irena

    2006-01-01

    The aim of the study was to evaluate the condition of the oral cavity in soldiers going on a military mission, the level of odontological assistance to them, and to prognosticate possible odontological problems during the mission period. We studied 50 soldiers going on a military mission in Iraq. During the study we applied odontological examination and panoramic imaging. We found that soldiers' teeth were treated, and they received comprehensive odontological assistance: 18% of soldiers had their teeth restored with single crowns and bridges, and 56% of soldiers had underwent endodontic treatment of their teeth. During the radiological examination we diagnosed individual cases of dental caries on the contact surfaces of teeth, and determined the level of the filling of root canals of endodontically treated teeth and the relationship of this level with radiological changes in apical periodontium. 67.3% of teeth had incompletely filled root canals, and radiological changes in their apical periodontium were reliably more frequent (80.6%) than in the apical periodontium of teeth with completely filled root canals (19.4%) (p<0.001). Of significant concern is the fact that frequently teeth with incompletely filled root canals and apical periodontal damage are restored using radical post-core and crowns. Radiological examination showed that in teeth with signs of chronic apical periodontitis and insufficient quality of filling, the condition may become more acute and cause odontological problems. A part of odontological problems in soldiers may be caused by incorrect position of the third molars in the jaw and possible aggravated eruption of these teeth.

  7. Radiological assessment. A textbook on environmental dose analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Till, J.E.; Meyer, H.R.

    1983-09-01

    Radiological assessment is the quantitative process of estimating the consequences to humans resulting from the release of radionuclides to the biosphere. It is a multidisciplinary subject requiring the expertise of a number of individuals in order to predict source terms, describe environmental transport, calculate internal and external dose, and extrapolate dose to health effects. Up to this time there has been available no comprehensive book describing, on a uniform and comprehensive level, the techniques and models used in radiological assessment. Radiological Assessment is based on material presented at the 1980 Health Physics Society Summer School held in Seattle, Washington. Themore » material has been expanded and edited to make it comprehensive in scope and useful as a text. Topics covered include (1) source terms for nuclear facilities and Medical and Industrial sites; (2) transport of radionuclides in the atmosphere; (3) transport of radionuclides in surface waters; (4) transport of radionuclides in groundwater; (5) terrestrial and aquatic food chain pathways; (6) reference man; a system for internal dose calculations; (7) internal dosimetry; (8) external dosimetry; (9) models for special-case radionuclides; (10) calculation of health effects in irradiated populations; (11) evaluation of uncertainties in environmental radiological assessment models; (12) regulatory standards for environmental releases of radionuclides; (13) development of computer codes for radiological assessment; and (14) assessment of accidental releases of radionuclides.« less

  8. Teaching, leadership, scholarly productivity, and level of activity in the chiropractic profession: a study of graduates of the Los Angeles College of Chiropractic radiology residency program

    PubMed Central

    Young, Kenneth J.; Siordia, Lawrence

    2012-01-01

    Objective The purpose of this study was to track the graduates of the Los Angeles College of Chiropractic (LACC) radiology residency program, review their scholarly productivity, and report those involved in teaching and leadership positions. Methods Former LACC residents’ career information was identified through publicly available electronic documents including Web sites and social media. PubMed and the Index to Chiropractic Literature databases were searched for chiropractic graduate job surveys, and proportional comparisons were made between the career paths of LACC radiology residency graduates and those of non–residency-trained chiropractors. Results Of 47 former LACC residents, 28 (60%) have or previously had careers in tertiary (chiropractic) education; and 12 (26%) have attained a department chair position or higher at tertiary teaching institutions. Twenty-two (47%) have or previously had private radiology practices, whereas 11 (23%) have or previously had clinical chiropractic practices. Often, residency graduates hold or have held 2 of these positions at once; and one, all 3. Chapters or books were authored by 13 (28%). Conclusion Radiology residency LACC graduates are professionally active, particularly in education, and demonstrate scholarly productivity. PMID:23966885

  9. Blending online techniques with traditional face to face teaching methods to deliver final year undergraduate radiology learning content.

    PubMed

    Howlett, David; Vincent, Tim; Watson, Gillian; Owens, Emma; Webb, Richard; Gainsborough, Nicola; Fairclough, Jil; Taylor, Nick; Miles, Ken; Cohen, Jon; Vincent, Richard

    2011-06-01

    To review the initial experience of blending a variety of online educational techniques with traditional face to face or contact-based teaching methods to deliver final year undergraduate radiology content at a UK Medical School. The Brighton and Sussex Medical School opened in 2003 and offers a 5-year undergraduate programme, with the final 5 spent in several regional centres. Year 5 involves several core clinical specialities with onsite radiology teaching provided at regional centres in the form of small-group tutorials, imaging seminars and also a one-day course. An online educational module was introduced in 2007 to facilitate equitable delivery of the year 5 curriculum between the regional centres and to support students on placement. This module had a strong radiological emphasis, with a combination of imaging integrated into clinical cases to reflect everyday practice and also dedicated radiology cases. For the second cohort of year 5 students in 2008 two additional online media-rich initiatives were introduced, to complement the online module, comprising imaging tutorials and an online case discussion room. In the first year for the 2007/2008 cohort, 490 cases were written, edited and delivered via the Medical School managed learning environment as part of the online module. 253 cases contained a form of image media, of which 195 cases had a radiological component with a total of 325 radiology images. Important aspects of radiology practice (e.g. consent, patient safety, contrast toxicity, ionising radiation) were also covered. There were 274,000 student hits on cases the first year, with students completing a mean of 169 cases each. High levels of student satisfaction were recorded in relation to the online module and also additional online radiology teaching initiatives. Online educational techniques can be effectively blended with other forms of teaching to allow successful undergraduate delivery of radiology. Efficient IT links and good image quality are essential ingredients for successful student/clinician engagement. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  10. Desmoplastic fibroma. A case report.

    PubMed

    van Straelen, P M; Pool, R; Mennen, U

    1988-11-19

    A desmoplastic fibroma occurring in the distal forearm of a 14-year-old black boy is described and the historical background of the tumour together with an outline of the disease emphasizes the differential diagnosis between this condition and other fibrous lesions of soft tissue and bone. The clinical and radiological features as well as the treatment of desmoplastic fibroma are discussed. It is believed that this is the first such patient reported in Africa.

  11. [Personal dose monitoring of radiation workers in medical institutions at the municipal level and below in a city from 2011 to 2014].

    PubMed

    Wang, C; Mo, S F; Zhang, J B; Li, J R; Huang, R L; Tan, H Y

    2017-08-20

    Objective: To determine the personal dose level of radiation workers in medical institutions at the municipal level and below in a city, and to provide a scientific support for strengthening the radiation protection in the city's medical institutions. Methods: Information of the successful applicants for the "Radiation Worker Permit" from 174 medical institutions at the municipal level and below was collected from October 1, 2011 to December 31, 2014. The annual effective dose was calculated based on the personal dose monitoring report, and indicators including sex, permit application time, hospital level, type of occupational radiation, length of radiation work, blood test, and micronucleated lymphocyte rate were analyzed. Results: Of the 1 143 radiation worker permit applications submitted by medical institutions the municipal level and below in this city from 2011 to 2014, 1 123 provided at least one personal dose monitoring report. The annual effective dose of the radiation workers was 0-4.76 mSv (mean 0.31±0.40 mSv) , and the collective annual effective dose was 351.96 mSv. The annual effective dose was significantly different between radiation workers with different times of permit application, hospital levels, and types of occupational radiation ( P <0.05) . Interventional radiology workers had the highest annual effective dose (0.63 mSv) , and annual effective dose was significantly different between interventional radiology workers with different lengths of radiation work ( H =10.812, P <0.05) . Conclusion: The personal radiation dose of radiation workers in medical institutions at the municipal level and below in this city is maintained at a relatively low level, suggesting that the occupational environment is relatively safe for these workers. However, more focus should be placed on clinical interventional radiology workers.

  12. Metal levels in corrosion of spinal implants

    PubMed Central

    Beguiristain, Jose; Duart, Julio

    2007-01-01

    Corrosion affects spinal instrumentations and may cause local and systemic complications. Diagnosis of corrosion is difficult, and nowadays it is performed almost exclusively by the examination of retrieved instrumentations. We conducted this study to determine whether it is possible to detect corrosion by measuring metal levels on patients with posterior instrumented spinal fusion. Eleven asymptomatic patients, with radiological signs of corrosion of their stainless steel spinal instrumentations, were studied by performing determinations of nickel and chromium in serum and urine. Those levels were compared with the levels of 22 patients with the same kind of instrumentation but without evidence of corrosion and to a control group of 22 volunteers without any metallic implants. Statistical analysis of our results revealed that the patients with spinal implants without radiological signs of corrosion have increased levels of chromium in serum and urine (P < 0.001) compared to volunteers without implants. Corrosion significantly raised metal levels, including nickel and chromium in serum and urine when compared to patients with no radiological signs of corrosion and to volunteers without metallic implants (P < 0.001). Metal levels measured in serum have high sensibility and specificity (area under the ROC curve of 0.981). By combining the levels of nickel and chromium in serum we were able to identify all the cases of corrosion in our series of patients. The results of our study confirm that metal levels in serum and urine are useful in the diagnosis of corrosion of spinal implants and may be helpful in defining the role of corrosion in recently described clinical entities such as late operative site pain or late infection of spinal implants. PMID:17256156

  13. Barriers and facilitators to adoption of soft copy interpretation from the user perspective: Lessons learned from filmless radiology for slideless pathology

    PubMed Central

    Patterson, Emily S.; Rayo, Mike; Gill, Carolina; Gurcan, Metin N.

    2011-01-01

    Background: Adoption of digital images for pathological specimens has been slower than adoption of digital images in radiology, despite a number of anticipated advantages for digital images in pathology. In this paper, we explore the factors that might explain this slower rate of adoption. Materials and Method: Semi-structured interviews on barriers and facilitators to the adoption of digital images were conducted with two radiologists, three pathologists, and one pathologist's assistant. Results: Barriers and facilitators to adoption of digital images were reported in the areas of performance, workflow-efficiency, infrastructure, integration with other software, and exposure to digital images. The primary difference between the settings was that performance with the use of digital images as compared to the traditional method was perceived to be higher in radiology and lower in pathology. Additionally, exposure to digital images was higher in radiology than pathology, with some radiologists exclusively having been trained and/or practicing with digital images. The integration of digital images both improved and reduced efficiency in routine and non-routine workflow patterns in both settings, and was variable across the different organizations. A comparison of these findings with prior research on adoption of other health information technologies suggests that the barriers to adoption of digital images in pathology are relatively tractable. Conclusions: Improving performance using digital images in pathology would likely accelerate adoption of innovative technologies that are facilitated by the use of digital images, such as electronic imaging databases, electronic health records, double reading for challenging cases, and computer-aided diagnostic systems. PMID:21383925

  14. Doctor-patient communication in radiology: a great opportunity for future radiology.

    PubMed

    Bazzocchi, M

    2012-04-01

    This text discusses several aspects of doctor-patient communication in radiology, including the origins, advantages, and ethical and legal aspects. Over the last 10 years, radiologists have assumed increasing responsibilities towards patients and society. Patients, who are becoming better informed and more aware about medical issues, have a right to be given a timely diagnosis and want to receive as much information as possible from the radiologist. This has implications for several levels of everyday radiological practice, including the organisation of work, legal and ethical aspects and radiologist training. Better interaction with the patient helps to build a closer, more trusting, relationship with the result that the radiologist will be more motivated in his or her work. Until now, radiologists were not adequately trained to communicate the diagnosis directly and verbally to patients, especially when the diagnosis was unfavourable. It is important to emphasise the need for more specific and practical training in this respect, which is indispensable for future developments of the discipline.

  15. A novel quality assurance method in a university teaching paediatric radiology department.

    PubMed

    Gallet, J M; Reed, M H; Hlady, J

    2000-08-01

    Primary diagnostic equipment in a paediatric radiology department must perform at optimal levels at all times. The Children's Hospital Radiology Department in Winnipeg, Canada, has developed an impartial means of reporting radiographic image quality. The main objectives of this study programme were two-fold. First, to monitor diagnostic X-ray equipment performance, and second, to improve the resultant image quality as a means of implementing the fundamental concepts of continuous quality improvement. Reading radiologists completed a quality assurance (QA) card when they identified a radiographic image quality problem. The cards were subsequently collected by the clinical instructor who then informed, in confidence, the radiographers of the written comments or concerns. QA cards have been conspicuously installed in the paediatric radiology reading room since the middle of 1993. Since its inception, equipment malfunction has been monitored and indicators for improving image quality developed. This component of the QA programme has shown itself to be a successful means of communicating with radiographers in maintaining superior image quality.

  16. Bridging the gap: linking a legacy hospital information system with a filmless radiology picture archiving and communications system within a nonhomogeneous environment.

    PubMed

    Rubin, R K; Henri, C J; Cox, R D

    1999-05-01

    A health level 7 (HL7)-conformant data link to exchange information between the mainframe hospital information system (HIS) of our hospital and our home-grown picture archiving and communications system (PACS) is a result of a collaborative effort between the HIS department and the PACS development team. Based of the ability to link examination requisitions and image studies, applications have been generated to optimise workflow and to improve the reliability and distribution of radiology information. Now, images can be routed to individual radiologists and clinicians; worklists facilitate radiology reporting; applications exist to create, edit, and view reports and images via the internet; and automated quality control now limits the incidence of "lost" cases and errors in image routing. By following the HL7 standard to develop the gateway to the legacy system, the development of a radiology information system for booking, reading, reporting, and billing remains universal and does not preclude the option to integrate off-the-shelf commercial products.

  17. White Paper Report of the 2011 RAD-AID Conference on International Radiology for Developing Countries: Integrating Multidisciplinary Strategies for Imaging Services in the Developing World

    PubMed Central

    Mazal, Jonathan; Lexa, Frank; Starikovsky, Anna; Jimenez, Pablo; Jain, Sanjay; DeStigter, Kristen K.; Nathan, Robert; Krebs, Elizabeth; Noble, Vicki; Marks, William; Hirsh, Richard N.; Short, Brad; Sydnor, Ryan; Timmreck-Jackson, Emily; Lungren, Matthew P.; Maxfield, Charles; Azene, Ezana M.; Garra, Brian S.; Choi, Brian G.; Lewin, Jonathan S.; Mollura, Daniel J.

    2016-01-01

    The 2011 RAD-AID Conference on International Radiology for Developing Countries discussed data, experiences and models pertaining to radiology in the developing world, where widespread shortages of imaging services significantly reduce health care quality and increase health care disparity. This white paper from the 2011 RAD-AID Conference represents consensus advocacy of multidisciplinary strategies to improve planning, accessibility and quality of imaging services in the developing world. Conference presenters and participants discussed numerous solutions to imaging and healthcare disparities including: (1) economic development for radiology service planning, (2) public health mechanisms to address disease and prevention at the population and community levels, (3) comparative clinical models to implement various clinical and workflow strategies adapted to unique developing world community contexts, (4) education to improve training and optimize service quality, and (5) technology innovation to bring new technical capabilities to limited-resource regions. PMID:22748790

  18. White paper report of the 2011 RAD-AID Conference on International Radiology for Developing Countries: integrating multidisciplinary strategies for imaging services in the developing world.

    PubMed

    Everton, Kathryn L; Mazal, Jonathan; Mollura, Daniel J

    2012-07-01

    The 2011 RAD-AID Conference on International Radiology for Developing Countries discussed data, experiences, and models pertaining to radiology in the developing world, where widespread shortages of imaging services significantly reduce health care quality and increase health care disparities. This white paper from the 2011 RAD-AID conference represents consensus advocacy of multidisciplinary strategies to improve the planning, accessibility, and quality of imaging services in the developing world. Conference presenters and participants discussed numerous solutions to imaging and health care disparities, including (1) economic development for radiologic service planning, (2) public health mechanisms to address disease and prevention at the population and community levels, (3) comparative clinical models to implement various clinical and workflow strategies adapted to unique developing world community contexts, (4) education to improve training and optimize service quality, and (5) technology innovation to bring new technical capabilities to limited-resource regions. Published by Elsevier Inc.

  19. A four-alternative forced choice (4AFC) software for observer performance evaluation in radiology

    NASA Astrophysics Data System (ADS)

    Zhang, Guozhi; Cockmartin, Lesley; Bosmans, Hilde

    2016-03-01

    Four-alternative forced choice (4AFC) test is a psychophysical method that can be adopted for observer performance evaluation in radiological studies. While the concept of this method is well established, difficulties to handle large image data, perform unbiased sampling, and keep track of the choice made by the observer have restricted its application in practice. In this work, we propose an easy-to-use software that can help perform 4AFC tests with DICOM images. The software suits for any experimental design that follows the 4AFC approach. It has a powerful image viewing system that favorably simulates the clinical reading environment. The graphical interface allows the observer to adjust various viewing parameters and perform the selection with very simple operations. The sampling process involved in 4AFC as well as the speed and accuracy of the choice made by the observer is precisely monitored in the background and can be easily exported for test analysis. The software has also a defensive mechanism for data management and operation control that minimizes the possibility of mistakes from user during the test. This software can largely facilitate the use of 4AFC approach in radiological observer studies and is expected to have widespread applicability.

  20. Visualisation of the Bonebridge by means of CT and CBCT

    PubMed Central

    2013-01-01

    Background With the Bonebridge, a new bone-anchored hearing aid has been available since March 2012. The objective of the study was to analyse the visualisation of the implant itself as well as its impact on the representation of the bony structures of the petrosal bone in CT, MRI and cone beam CT (CBCT). Methods The Bonebridge was implanted unilaterally in two completely prepared human heads. The radiological imaging by means of CBCT, 64-slice CT, 1.5-T and 3.0-T MRI was conducted both preoperatively and postoperatively. The images were subsequently evaluated from both the ENT medical and nd radiological perspectives. Results As anticipated, no visualisation of the implant or of the petrosal bones could be realised on MRI because of the interactive technology and the magnet artefact. In contrast, an excellent evaluability of the implant itself as well as of the surrounding neurovascular structures (sinus sigmoideus, skull base, middle ear, inner ear, inner auditory canal) was exhibited in both the CT and in the CBCT. Conclusion The Bonebridge can be excellently imaged with the radiological imaging technologies of CT and CBCT. In the process, CBCT shows discrete advantages in comparison with CT. No relevant restrictions in image quality in the evaluation of the bony structures of the petrosal bones could be seen. PMID:24004903

  1. Radiological Environmental Protection for LCLS-II High Power Operation

    NASA Astrophysics Data System (ADS)

    Liu, James; Blaha, Jan; Cimeno, Maranda; Mao, Stan; Nicolas, Ludovic; Rokni, Sayed; Santana, Mario; Tran, Henry

    2017-09-01

    The LCLS-II superconducting electron accelerator at SLAC plans to operate at up to 4 GeV and 240 kW average power, which would create higher radiological impacts particularly near the beam loss points such as beam dumps and halo collimators. The main hazards to the public and environment include direct or skyshine radiation, effluent of radioactive air such as 13N, 15O and 41Ar, and activation of groundwater creating tritium. These hazards were evaluated using analytic methods and FLUKA Monte Carlo code. The controls (mainly extensive bulk shielding and local shielding around high loss points) and monitoring (neutron/photon detectors with detection capabilities below natural background at site boundary, site-wide radioactive air monitors, and groundwater wells) were designed to meet the U.S. DOE and EPA, as well as SLAC requirements. The radiological design and controls for the LCW systems [including concrete housing shielding for 15O and 11C circulating in LCW, 7Be and erosion/corrosion products (22Na, 54Mn, 60Co, 65Zn, etc.) captured in resin and filters, leak detection and containment of LCW with 3H and its waste water discharge; explosion from H2 build-up in surge tank and release of radionuclides] associated with the high power beam dumps are also presented.

  2. Cervical spine anomalies in Menkes disease: a radiologic finding potentially confused with child abuse

    PubMed Central

    Hill, Suvimol C.; Dwyer, Andrew J.

    2012-01-01

    Background Menkes disease is an X-linked recessive disorder of copper transport caused by mutations in ATP7A, a copper-transporting ATPase. Certain radiologic findings reported in this condition overlap with those caused by child abuse. However, cervical spine defects simulating cervical spine fracture, a known result of nonaccidental pediatric trauma, have not been reported previously in this illness. Objective To assess the frequency of cervical spine anomalies in Menkes disease after discovery of an apparent C2 posterior arch defect in a child participating in a clinical trial. Materials and methods We examined cervical spine radiographs obtained in 35 children with Menkes disease enrolled in a clinical trial at the National Institutes of Health Clinical Center. Results Four of the 35 children with Menkes disease had apparent C2 posterior arch defects consistent with spondylolysis or incomplete/delayed ossification. Conclusion Defects in C2 were found in 11% of infants and young children with Menkes disease. Discovery of cervical spine defects expands the spectrum of radiologic findings associated with this condition. As with other skeletal abnormalities, this feature simulates nonaccidental trauma. In the context of Menkes disease, suspicions of child abuse should be considered cautiously and tempered by these findings to avoid unwarranted accusations. PMID:22825777

  3. Quantitative evaluation of expression difference in report assignments between nursing and radiologic technology departments.

    PubMed

    Nishimoto, Naoki; Yokooka, Yuki; Yagahara, Ayako; Uesugi, Masahito; Ogasawara, Katsuhiko

    2011-01-01

    Our purpose in this study was to investigate the expression differences in report assignments between students in nursing and radiologic technology departments. We have known that faculties could identify differences, such as word usage, through grading their students' assignments. However, there are no reports in the literature dealing with expression differences in vocabulary usage in medical informatics education based on statistical techniques or other quantitative measures. The report assignment asked for students' opinions in the event that they found a rare case of a disease in a hospital after they graduated from professional school. We processed student report data automatically, and we applied the space vector model and TF/IDF (term frequency/inverse document frequency) scoring to 129 report assignments. The similarity-score distributions among the assignments for these two departments were close to normal. We focused on the sets of terms that occurred exclusively in either department. For terms such as "radiation therapy" or "communication skills" that occurred in the radiologic technology department, the TF/IDF score was 8.01. The same score was obtained for terms such as "privacy guidelines" or "consent of patients" that occurred in the nursing department. These results will help faculties to provide a better education based on identified expression differences from students' background knowledge.

  4. Evaluation of clinicians' knowledge and practices regarding medical radiological exposure: findings from a mixed-methods investigation (survey and qualitative study)

    PubMed Central

    Lumbreras, B; Vilar, J; González-Álvarez, I; Guilabert, M; Parker, L A; Pastor-Valero, M; Domingo, M L; Fernández-Lorente, M F; Hernández-Aguado, I

    2016-01-01

    Objectives To assess the impact of initiatives aiming to increase clinician awareness of radiation exposure; to explore the challenges they face when communicating with patients; to study what they think is the most appropriate way of communicating the long-term potential risks of medical radiological exposure to patients. Design A quantitative and qualitative evaluation through a survey and focal groups. Setting San Juan Hospital and Dr Peset Hospital (Southeast Spain) and clinicians from Spanish scientific societies. Participants The surveys were answered (a) in person (216: all the radiologists (30), urologists (14) and surgeons (44) working at both participant hospitals; a sample of general practitioners from the catchment area of one hospital (45), and a consecutive sample of radiologists attending a scientific meeting (60)) or (b) electronically through Spanish scientific societies (299: radiologists (45), pneumologists (123), haematologists (75) and surgeons (40)). Clinicians were not randomly selected and thus the results are limited by the diligence of the individuals filling out the survey. Primary and secondary outcome measures Clinicians' knowledge and practices regarding medical radiological exposure, and what they considered most appropriate for communicating information to patients. Results Nearly 80% of the clinicians surveyed had never heard of the European recommendations. Fewer than 20% of the clinicians surveyed identified correctly the radiation equivalence dose of intravenous urography or barium enema. It was reported by 31.7% that they inform patients about the long-term potential risks of ionising radiation. All participants agreed that the most appropriate way to present information is a table with a list of imaging tests and their corresponding radiation equivalence dose in terms of chest X-rays and background radiation exposure. Conclusions Medical radiological exposure is frequently underestimated and rarely explained to patients. With a clear understanding of medical radiological exposure and proper communication tools, clinicians will be able to accurately inform patients. PMID:27799242

  5. Using SAFRAN Software to Assess Radiological Hazards from Dismantling of Tammuz-2 Reactor Core at Al-tuwaitha Nuclear Site

    NASA Astrophysics Data System (ADS)

    Abed Gatea, Mezher; Ahmed, Anwar A.; jundee kadhum, Saad; Ali, Hasan Mohammed; Hussein Muheisn, Abbas

    2018-05-01

    The Safety Assessment Framework (SAFRAN) software has implemented here for radiological safety analysis; to verify that the dose acceptance criteria and safety goals are met with a high degree of confidence for dismantling of Tammuz-2 reactor core at Al-tuwaitha nuclear site. The activities characterizing, dismantling and packaging were practiced to manage the generated radioactive waste. Dose to the worker was considered an endpoint-scenario while dose to the public has neglected due to that Tammuz-2 facility is located in a restricted zone and 30m berm surrounded Al-tuwaitha site. Safety assessment for dismantling worker endpoint-scenario based on maximum external dose at component position level in the reactor pool and internal dose via airborne activity while, for characterizing and packaging worker endpoints scenarios have been done via external dose only because no evidence for airborne radioactivity hazards outside the reactor pool. The in-situ measurements approved that reactor core components are radiologically activated by Co-60 radioisotope. SAFRAN results showed that the maximum received dose for workers are (1.85, 0.64 and 1.3mSv/y) for activities dismantling, characterizing and packaging of reactor core components respectively. Hence, the radiological hazards remain below the low level hazard and within the acceptable annual dose for workers in radiation field

  6. Improved identification of noun phrases in clinical radiology reports using a high-performance statistical natural language parser augmented with the UMLS specialist lexicon.

    PubMed

    Huang, Yang; Lowe, Henry J; Klein, Dan; Cucina, Russell J

    2005-01-01

    The aim of this study was to develop and evaluate a method of extracting noun phrases with full phrase structures from a set of clinical radiology reports using natural language processing (NLP) and to investigate the effects of using the UMLS(R) Specialist Lexicon to improve noun phrase identification within clinical radiology documents. The noun phrase identification (NPI) module is composed of a sentence boundary detector, a statistical natural language parser trained on a nonmedical domain, and a noun phrase (NP) tagger. The NPI module processed a set of 100 XML-represented clinical radiology reports in Health Level 7 (HL7)(R) Clinical Document Architecture (CDA)-compatible format. Computed output was compared with manual markups made by four physicians and one author for maximal (longest) NP and those made by one author for base (simple) NP, respectively. An extended lexicon of biomedical terms was created from the UMLS Specialist Lexicon and used to improve NPI performance. The test set was 50 randomly selected reports. The sentence boundary detector achieved 99.0% precision and 98.6% recall. The overall maximal NPI precision and recall were 78.9% and 81.5% before using the UMLS Specialist Lexicon and 82.1% and 84.6% after. The overall base NPI precision and recall were 88.2% and 86.8% before using the UMLS Specialist Lexicon and 93.1% and 92.6% after, reducing false-positives by 31.1% and false-negatives by 34.3%. The sentence boundary detector performs excellently. After the adaptation using the UMLS Specialist Lexicon, the statistical parser's NPI performance on radiology reports increased to levels comparable to the parser's native performance in its newswire training domain and to that reported by other researchers in the general nonmedical domain.

  7. Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France.

    PubMed

    Etard, Cécile; Bigand, Emeline; Salvat, Cécile; Vidal, Vincent; Beregi, Jean Paul; Hornbeck, Amaury; Greffier, Joël

    2017-10-01

    A national retrospective survey on patient doses was performed by the French Society of Medical physicists to assess reference levels (RLs) in interventional radiology as required by the European Directive 2013/59/Euratom. Fifteen interventional procedures in neuroradiology, vascular radiology and osteoarticular procedures were analysed. Kerma area product (KAP), fluoroscopy time (FT), reference air kerma and number of images were recorded for 10 to 30 patients per procedure. RLs were calculated as the 3rd quartiles of the distributions. Results on 4600 procedures from 36 departments confirmed the large variability in patient dose for the same procedure. RLs were proposed for the four dosimetric estimators and the 15 procedures. RLs in terms of KAP and FT were 90 Gm.cm 2 and 11 mins for cerebral angiography, 35 Gy.cm 2 and 16 mins for biliary drainage, 75 Gy.cm 2 and 6 mins for lower limbs arteriography and 70 Gy.cm 2 and 11 mins for vertebroplasty. For these four procedures, RLs were defined according to the complexity of the procedure. For all the procedures, the results were lower than most of those already published. This study reports RLs in interventional radiology based on a national survey. Continual evolution of practices and technologies requires regular updates of RLs. • Delivered dose in interventional radiology depends on procedure, practice and patient. • National RLs are proposed for 15 interventional procedures. • Reference levels (RLs) are useful to benchmark practices and optimize protocols. • RLs are proposed for kerma area product, air kerma, fluoroscopy time and number of images. • RLs should be adapted to the procedure complexity and updated regularly.

  8. Proposed method to calculate FRMAC intervention levels for the assessment of radiologically contaminated food and comparison of the proposed method to the U.S. FDA's method to calculate derived intervention levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kraus, Terrence D.; Hunt, Brian D.

    This report reviews the method recommended by the U.S. Food and Drug Administration for calculating Derived Intervention Levels (DILs) and identifies potential improvements to the DIL calculation method to support more accurate ingestion pathway analyses and protective action decisions. Further, this report proposes an alternate method for use by the Federal Emergency Radiological Assessment Center (FRMAC) to calculate FRMAC Intervention Levels (FILs). The default approach of the FRMAC during an emergency response is to use the FDA recommended methods. However, FRMAC recommends implementing the FIL method because we believe it to be more technically accurate. FRMAC will only implement themore » FIL method when approved by the FDA representative on the Federal Advisory Team for Environment, Food, and Health.« less

  9. A national patient dose survey and setting of reference levels for interventional radiology in Bulgaria.

    PubMed

    Zotova, R; Vassileva, J; Hristova, J; Pirinen, M; Järvinen, H

    2012-06-01

    A national study on patient dose values in interventional radiology and cardiology was performed in order to assess current practice in Bulgaria, to estimate the typical patient doses and to propose reference levels for the most common procedures. Fifteen units and more than 1,000 cases were included. Average values of the measured parameters for three procedures-coronary angiography (CA), combined procedure (CA + PCI) and lower limb arteriography (LLA)--were compared with data published in the literature. Substantial variations were observed in equipment and procedure protocols used. This resulted in variations in patient dose: air-kerma area product ranges were 4-339, 6-1,003 and 0.2-288 Gy cm(2) for CA, CA + PCI and LLA respectively. Reference levels for air kerma-area product were proposed: 40 Gy cm(2) for CA, 140 Gy cm(2) for CA + PCI and 45 Gy cm(2) for LLA. Auxiliary reference intervals were proposed for other dose-related parameters: fluoroscopy time, number of images and entrance surface air kerma rate in fluoroscopy and cine mode. There is an apparent necessity for improvement in the classification of peripheral procedures and for standardisation of the protocols applied. It is important that patient doses are routinely recorded and compared with reference levels. • Patient doses in interventional radiology are high and vary greatly • Better standardisation of procedures and techniques is needed to improve practice • Dose reference levels for most common procedures are proposed.

  10. Modeling Urban Scenarios & Experiments: Fort Indiantown Gap Data Collections Summary and Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Archer, Daniel E.; Bandstra, Mark S.; Davidson, Gregory G.

    This report summarizes experimental radiation detector, contextual sensor, weather, and global positioning system (GPS) data collected to inform and validate a comprehensive, operational radiation transport modeling framework to evaluate radiation detector system and algorithm performance. This framework will be used to study the influence of systematic effects (such as geometry, background activity, background variability, environmental shielding, etc.) on detector responses and algorithm performance using synthetic time series data. This work consists of performing data collection campaigns at a canonical, controlled environment for complete radiological characterization to help construct and benchmark a high-fidelity model with quantified system geometries, detector response functions,more » and source terms for background and threat objects. This data also provides an archival, benchmark dataset that can be used by the radiation detection community. The data reported here spans four data collection campaigns conducted between May 2015 and September 2016.« less

  11. Recent Transport History of Fukushima Radioactivity in the Northeast Pacific Ocean.

    PubMed

    Smith, John N; Rossi, Vincent; Buesseler, Ken O; Cullen, Jay T; Cornett, Jack; Nelson, Richard; Macdonald, Alison M; Robert, Marie; Kellogg, Jonathan

    2017-09-19

    The large inventory of radioactivity released during the March, 2011 Fukushima Dai-ichi nuclear reactor accident in Japan spread rapidly across the North Pacific Ocean and was first observed at the westernmost station on Line P, an oceanographic sampling line extending 1500 km westward of British Columbia (BC), Canada in June 2012. Here, time series measurements of 134 Cs and 137 Cs in seawater on Line P and on the CLIVAR-P16N 152°W line reveal the recent transport history of the Fukushima radioactivity tracer plume through the northeast Pacific Ocean. During 2013 and 2014 the Fukushima plume spread onto the Canadian continental shelf and by 2015 and early 2016 it reached 137 Cs values of 6-8 Bq/m 3 in surface water along Line P. Ocean circulation model simulations that are consistent with the time series measurements of Fukushima 137 Cs indicate that the 2015-2016 results represent maximum tracer levels on Line P and that they will begin to decline in 2017-2018. The current elevated Fukushima 137 Cs levels in seawater in the eastern North Pacific are equivalent to fallout background levels of 137 Cs that prevailed during the 1970s and do not represent a radiological threat to human health or the environment.

  12. Radiographer perceptions of managerial transformational leadership levels.

    PubMed

    Legg, Jeffrey S; Akroyd, Duane; Jackowski, Melissa B

    2010-01-01

    Transformational leadership focuses on the ability of a leader to impact employees by inspiring employees to broaden interests in work as well as to be innovative and creative. It is positively associated with employee satisfaction and commitment to the organization. Characteristics of transformational leaders include confidence, ability to mange and deal with complexity, and belief in their employees and organizations. Considering the importance of leadership skills in radiology departments, this paper addresses directly the empirical evidence concerning radiographer's perception of their radiology managers and supervisors transformational leadership levels in the United States. Leadership can be taught, and we as a profession must begin to implement leadership training programs for our current and future leaders.

  13. Federal Radiological Monitoring and Assessment Center Health and Safety Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    FRMAC Health and Safety Working Group

    2012-03-20

    This manual is a tool to provide information to all responders and emergency planners and is suggested as a starting point for all organizations that provide personnel/assets for radiological emergency response. It defines the safety requirements for the protection of all emergency responders. The intent is to comply with appropriate regulations or provide an equal level of protection when the situation makes it necessary to deviate. In the event a situation arises which is not addressed in the manual, an appropriate management-level expert will define alternate requirements based on the specifics of the emergency situation. This manual is not intendedmore » to pertain to the general public.« less

  14. Can D-Dimer Measurement Reduce the Frequency of Radiological Assessment in Patients Receiving Palliative Imatinib for Gastrointestinal Stromal Tumor (GIST)?

    PubMed

    Afshar, Mehran; Hamilton, Patrick; Seligmann, Jenny; Lord, Simon; Baxter, Paul; Marples, Maria; Stark, Dan; Hall, Peter S

    2015-01-01

    Imatinib therapy has improved outcomes in advanced GISTs. Current guidelines suggest monitoring with CT scanning every 12 weeks. There are no validated biomarkers to assist disease evaluation. We identified 50 patients treated with imatinib for GIST in a single tertiary center. We assessed the prognostic value of D-dimers by Cox regression, and the utility as a biomarker for radiological progression (rPD) using receiver-operator curve (ROC) analysis. In asymptomatic patients with D-dimer levels <1,000 and falling levels, the negative predictive value for rPD was 92%. D-dimers may reduce the burden of CT scanning in a proportion of patients in this setting.

  15. An Overview of the Regulation of Low Dose Radiation in the Nuclear and Non-nuclear Industries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menon, Shankar; Valencia, Luis; Teunckens, Lucien

    Now that increasing numbers of nuclear power stations are reaching the end of their commercially useful lives, the management of the large quantities of very low level radioactive material that arises during their decommissioning has become a major subject of discussion, with very significant economic implications. Much of this material can, in an environmentally advantageous manner, be recycled for reuse without radiological restrictions. Much larger quantities--2-3 orders of magnitude larger--of material, radiologically similar to the candidate material for recycling from the nuclear industry, arise in non-nuclear industries like coal, fertilizer, oil and gas, mining, etc. In such industries, naturally occurringmore » radioactivity is artificially concentrated in products, by-products or waste to form TENORM (Technologically Enhanced Naturally Occurring Radioactive Material). It is only in the last decade that the international community has become aware of the prevalence of TENORM, specially the activity levels and quantities arising in so many non-nuclear industries. The first reaction of international organizations seems to have been to propose different standards for the nuclear and non-nuclear industries, with very stringent release criteria for radioactive material from the regulated nuclear industry and up to thirty to a hundred times more liberal criteria for the release/exemption of TENORM from the as yet unregulated non-nuclear industries. There are significant strategic issues that need to be discussed and resolved. Some examples of these are: - Disposal aspects of long-lived nuclides, - The use of radioactive residues in building materials, - Commercial aspects of differing and discriminating criteria in competing power industries in a world of deregulated electric power production. Of even greater importance is the need for the discussion of certain basic issues, such as - The quantitative risk levels of exposure to ionizing radiation, - The need for in-depth studies on populations of the naturally high background dose level areas of the world, - The validity of the various calculation codes currently used to arrive at mass specific clearance levels for redundant material. The paper discusses these and other strategic issues regarding the management of redundant low radiation material from both the nuclear and non-nuclear industries, underlining the need for consistency in regulatory treatment.« less

  16. Potential presence of metals in patients treated with metal-metal coupling prostheses for hip arthroplasty at 7 and 10 years of follow-up.

    PubMed

    Sessa, Giuseppe; Testa, Gianluca; Gioitta Iachino, Salvatore; Costarella, Luciano; Puma Pagliarello, Calogero; Ferrante, Margherita; Grasso, Alfina; Pavone, Vito

    2018-05-01

    Beginning in 2008, metal-on-metal prostheses have been in the spotlight owing to much higher revision rates than expected. Adverse local tissue reactions have been well described in the literature as potential complications. Between 2012 and 2013, 13 patients with metal-on-metal total hip replacements were evaluated clinically and radiologically and with laboratory samples. The same tests were repeated between 2015 and 2016 on eight patients to assess any changes. In the laboratory assessment, we searched for chromium, cobalt, molybdenum, and nickel in blood and urine samples over 24 h. Clinical assessment has shown good score in all patients except one. On a second examination, between 2015 and 2016, all patients obtained results similar to those obtained in the first assessment, except a patient, who reported a recent fall. In the radiological assessment between 2012 and 2013, results were optimal, apart from a case of aseptic mobilization. The patients reassessed 3 years after the first examination showed radiological results similar to those previously obtained, apart from a patient, who showed signals of mobilization. Metal levels found in their blood decreased in most cases after 3 years. Urine levels of nickel increased in five subjects, and chromium levels increased in four, but levels of cobalt and molybdenum decreased in four patients. It could be hypothesized that the decreasing trend of metal ion levels is associated with a stable wear status. On the contrary, a progressive increase in metal ion levels must be considered as early proof of implant loosening.

  17. A content-boosted collaborative filtering algorithm for personalized training in interpretation of radiological imaging.

    PubMed

    Lin, Hongli; Yang, Xuedong; Wang, Weisheng

    2014-08-01

    Devising a method that can select cases based on the performance levels of trainees and the characteristics of cases is essential for developing a personalized training program in radiology education. In this paper, we propose a novel hybrid prediction algorithm called content-boosted collaborative filtering (CBCF) to predict the difficulty level of each case for each trainee. The CBCF utilizes a content-based filtering (CBF) method to enhance existing trainee-case ratings data and then provides final predictions through a collaborative filtering (CF) algorithm. The CBCF algorithm incorporates the advantages of both CBF and CF, while not inheriting the disadvantages of either. The CBCF method is compared with the pure CBF and pure CF approaches using three datasets. The experimental data are then evaluated in terms of the MAE metric. Our experimental results show that the CBCF outperforms the pure CBF and CF methods by 13.33 and 12.17 %, respectively, in terms of prediction precision. This also suggests that the CBCF can be used in the development of personalized training systems in radiology education.

  18. Comparable clinical and radiological outcomes between skipped-level and all-level plating for open-door laminoplasty.

    PubMed

    Cheung, Jason Pui Yin; Cheung, Prudence Wing Hang; Cheung, Amy Yim Ling; Lui, Darren; Cheung, Kenneth M C

    2018-06-01

    To compare the clinical and radiological outcomes between skipped-level and all-level plating for cervical laminoplasty. Patients with cervical spondylotic myelopathy (CSM) treated by open-door laminoplasty with minimum 2-year postoperative follow-up were included. All patients had opening from C3-6 or C3-7 and were divided into skipped-level or all-level plating groups. Japanese Orthopaedic Association (JOA) scores and canal measurements were obtained preoperatively, immediate (within 1 week) postoperatively, and at 2, 6 weeks, 3, 6 and 12 months postoperatively. Paired t test was used for comparative analysis. Receiver operating characteristic analysis was used to determine the canal expansion cutoff for spring-back closure. A total of 74 subjects were included with mean age of 66.1 ± 11.3 years at surgery. Of these, 32 underwent skipped-level plating and 42 underwent all-level plating. No significant differences were noted between the two groups at baseline and follow-up. Spring-back closure was observed in up to 50% of the non-plated levels within 3 months postoperatively. The cutoff for developing spring-back closure was 7 mm canal expansion for C3-6. No differences were observed in JOA scores and recovery rates between the two groups. None of the patients with spring-back required reoperation. There were no significant differences between skipped-level and all-level plating in terms of JOA or recovery rate, and canal diameter differences. This has tremendous impact on saving costs in CSM management as up to two plates per patient undergoing a standard C3-6 laminoplasty may be omitted instead of four plates to every level to achieve similar clinical and radiological outcomes. III. These slides can be retrieved under Electronic Supplementary Material.

  19. Reducing Unnecessary Portable Pelvic Radiographs in Trauma Patients: A Resident-Driven Quality Improvement Initiative.

    PubMed

    Langer, Jessica M; Tsai, Emily B; Luhar, Aarti; McWilliams, Justin; Motamedi, Kambiz

    2015-09-01

    Quality improvement is increasingly important in the changing health care climate. We aim to establish a methodology and identify critical factors leading to successful implementation of a resident-led radiology quality improvement intervention at the institutional level. Under guidance of faculty mentors, the first-year radiology residents developed a quality improvement initiative to decrease unnecessary STAT pelvic radiographs (PXRs) in hemodynamically stable trauma patients who would additionally receive STAT pelvic CT scans. Development and implementation of this initiative required multiple steps, including: establishing resident and faculty leadership, gathering evidence from published literature, cultivating multidisciplinary support, and developing and implementing an institution-wide ordering algorithm. A visual aid and brief questionnaire were distributed to clinicians for use during treatment of trauma cases to ensure sustainability of the initiative. At multiple time points, pre- and post-intervention, residents performed a retrospective chart review to evaluate changes in imaging-ordering trends for trauma patients. Chart review showed a decline in the number of PXRs for hemodynamically stable trauma patients, as recommended in the ordering algorithm: 78% of trauma patients received both a PXR and a pelvic CT scan in the first 24 hours of the initiative, compared with 26% at 1 month; 24% at 6 months; and 18% at 10 to 12 months postintervention. The resident-led radiology quality improvement initiative created a shift in ordering culture at an institutional level. Development and implementation of this algorithm exemplified the impact of a multidisciplinary collaborative effort involving multiple departments and multiple levels of the medical hierarchy. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  20. Cumulative radiation dose caused by radiologic studies in critically ill trauma patients.

    PubMed

    Kim, Patrick K; Gracias, Vicente H; Maidment, Andrew D A; O'Shea, Michael; Reilly, Patrick M; Schwab, C William

    2004-09-01

    Critically ill trauma patients undergo many radiologic studies, but the cumulative radiation dose is unknown. The purpose of this study was to estimate the cumulative effective dose (CED) of radiation resulting from radiologic studies in critically ill trauma patients. The study group was composed of trauma patients at an urban Level I trauma center with surgical intensive care unit length of stay (LOS) greater than 30 days. The radiology records were reviewed. A typical effective dose per study for each type of plain film radiograph, computed tomographic scan, fluoroscopic study, and nuclear medicine study was used to calculate CED. Forty-six patients met criteria. The mean surgical intensive care unit and hospital LOS were 42.7 +/- 14.0 and 59.5 +/- 28.5 days, respectively. The mean Injury Severity Score was 32.2 +/- 15.0. The mean number of studies per patient was 70.1 +/- 29.0 plain film radiographs, 7.8 +/- 4.1 computed tomographic scans, 2.5 +/- 2.6 fluoroscopic studies, and 0.065 +/- 0.33 nuclear medicine study. The mean CED was 106 +/- 59 mSv per patient (range, 11-289 mSv; median, 104 mSv). Among age, mechanism, Injury Severity Score, and LOS, there was no statistically significant predictor of high CED. The mean CED in the study group was 30 times higher than the average yearly radiation dose from all sources for individuals in the United States. The theoretical additional morbidity attributable to radiologic studies was 0.78%. From a radiobiologic perspective, risk-to-benefit ratios of radiologic studies are favorable, given the importance of medical information obtained. Current practice patterns regarding use of radiologic studies appear to be acceptable.

  1. Clinical compliance of viewing conditions in radiology reporting environments against current guidelines and standards

    NASA Astrophysics Data System (ADS)

    Daly, S.; Rainford, L.; Butler, M. L.

    2014-03-01

    Several studies have demonstrated the importance of environmental conditions in the radiology reporting environment, with many indicating that incorrect parameters could lead to error and misinterpretation. Literature is available with recommendations as to the levels that should be achieved in clinical practice, but evidence of adherence to these guidelines in radiology reporting environments is absent. This study audited the reporting environments of four teleradiologist and eight hospital based radiology reporting areas. This audit aimed to quantify adherence to guidelines and identify differences in the locations with respect to layout and design, monitor distance and angle as well as the ambient factors of the reporting environments. In line with international recommendations, an audit tool was designed to enquire in relation to the layout and design of reporting environments, monitor angle and distances used by radiologists when reporting, as well as the ambient factors such as noise, light and temperature. The review of conditions were carried out by the same independent auditor for consistency. The results obtained were compared against international standards and current research. Each radiology environment was given an overall compliance score to establish whether or not their environments were in line with recommended guidelines. Poor compliance to international recommendations and standards among radiology reporting environments was identified. Teleradiology reporting environments demonstrated greater compliance than hospital environments. The findings of this study identified a need for greater awareness of environmental and perceptual issues in the clinical setting. Further work involving a larger number of clinical centres is recommended.

  2. A web based Foundations of Radiological Physics for diagnostic radiology residents.

    PubMed

    Blackmon, Kevin N; Huda, Walter; Lewis, Madelene C; Tipnis, Sameer; Mah, Eugene; Frey, Donald G

    2013-03-01

    RATIONALE AND OBJECTS: We describe a new web-based physics course for radiology residents preparing for the Exam of the Future (EOF). A course was developed with a total of 12 web-based modules. Six modules were focused on "imaging" and six on "radiation." A module was subdivided into nine short "nuggets." Traditional lectures were replaced by modules using prerecorded lectures (Tegrity) to a secure website (WebCT). Each module was accompanied by three quizzes, each consisting of ten questions designed to reinforce covered materials. All online modules were accompanied by a noon conference that employed an Audience Response System (Turning Point). Seventeen first-year residents over 2 consecutive years beginning in July 2010 took this new course, and participated in an anonymous online follow-up survey (Survey Monkey). The recorded 12 modules had an overall average duration of 72 ± 19 minutes. Ten of 17 residents expressed a preference of 15 minutes for nugget duration. Highest personal assessment scores of each resident's understanding were obtained in human radiation risks and radiation protection. Residents considered supplemental noon conferences to be important for learning radiological physics. Satisfaction level was largely positive, with five residents highly satisfied, nine residents somewhat satisfied, two residents neutral, and only one resident somewhat dissatisfied. Our Foundations of Radiological Physics course was well received and served as the springboard for mastering x-ray-based imaging modalities of radiography, mammography, fluoroscopy, interventional radiology, and computed tomography. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  3. Decision theory applied to image quality control in radiology.

    PubMed

    Lessa, Patrícia S; Caous, Cristofer A; Arantes, Paula R; Amaro, Edson; de Souza, Fernando M Campello

    2008-11-13

    The present work aims at the application of the decision theory to radiological image quality control (QC) in diagnostic routine. The main problem addressed in the framework of decision theory is to accept or reject a film lot of a radiology service. The probability of each decision of a determined set of variables was obtained from the selected films. Based on a radiology service routine a decision probability function was determined for each considered group of combination characteristics. These characteristics were related to the film quality control. These parameters were also framed in a set of 8 possibilities, resulting in 256 possible decision rules. In order to determine a general utility application function to access the decision risk, we have used a simple unique parameter called r. The payoffs chosen were: diagnostic's result (correct/incorrect), cost (high/low), and patient satisfaction (yes/no) resulting in eight possible combinations. Depending on the value of r, more or less risk will occur related to the decision-making. The utility function was evaluated in order to determine the probability of a decision. The decision was made with patients or administrators' opinions from a radiology service center. The model is a formal quantitative approach to make a decision related to the medical imaging quality, providing an instrument to discriminate what is really necessary to accept or reject a film or a film lot. The method presented herein can help to access the risk level of an incorrect radiological diagnosis decision.

  4. Developing a Job Description for a Vice Chair of Education in Radiology: The ADVICER Template.

    PubMed

    Lewis, Petra J; Probyn, Linda; McGuinness, Georgeann; Nguyen, Jeremy; Mullins, Mark E; Resnik, Charles; Oldham, Sandra

    2015-07-01

    The newly formed Alliance of Directors and Vice Chairs of Education in Radiology (ADVICER), a group within the Alliance for Clinician Educators in Radiology, identified an acute need for a generic job description template for Vice Chairs of Education in Radiology, a role that is being developed in many academic Departments of Radiology. Eighty-three percent of current members who responded to a survey had no detailed job description, and over half had no job description at all. Having a comprehensive and detailed job description is vital to developing this key position. Using the results of a survey sent to ADVICER members and seven Education Vice Chair job descriptions provided by members, the authors developed a detailed job description encompassing all potential elements of this position. Only 17% of survey respondents had a detailed job description. The role of an Education Vice Chair varies significantly between institutions in its scope and level of responsibilities. The resultant generic job description that was devised is intended to provide a template that would be modified by the candidate or the Department Chair. It is unlikely that any one individual would perform all the described activities. ADVICER has developed a comprehensive, flexible job description for Vice Chair of Education in Radiology that can be adapted by institutions as appropriate. It can be downloaded from http://aur.org/ADVICER/. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  5. Core curriculum for medical physicists in radiology. Recommendations from an EFOMP/ESR working group.

    PubMed

    Geleijns, Jacob; Breatnach, Eamann; Cantera, Alfonso Calzado; Damilakis, John; Dendy, Philip; Evans, Anthony; Faulkner, Keith; Padovani, Renato; Van Der Putten, Wil; Schad, Lothar; Wirestam, Ronnie; Eudaldo, Teresa

    2012-06-01

    Some years ago it was decided that a European curriculum should be developed for medical physicists professionally engaged in the support of clinical diagnostic imaging departments. With this in mind, EFOMP (European Federation of Organisations for Medical Physics) in association with ESR (European Society of Radiology) nominated an expert working group. This curriculum is now to hand. The curriculum is intended to promote best patient care in radiology departments through the harmonization of education and training of medical physicists to a high standard in diagnostic radiology. It is recommended that a medical physicist working in a radiology department should have an advanced level of professional expertise in X-ray imaging, and additionally, depending on local availability, should acquire knowledge and competencies in overseeing ultrasound imaging, nuclear medicine, and MRI technology. By demonstrating training to a standardized curriculum, medical physicists throughout Europe will enhance their mobility, while maintaining local high standards of medical physics expertise. This document also provides the basis for improved implementation of articles in the European medical exposure directives related to the medical physics expert. The curriculum is divided into three main sections: The first deals with general competencies in the principles of medical physics. The second section describes specific knowledge and skills required for a medical physicist (medical physics expert) to operate clinically in a department of diagnostic radiology. The final section outlines research skills that are also considered to be necessary and appropriate competencies in a career as medical physicist.

  6. Radiological impact assessment to the environment due to waste from disposal of porcelain.

    PubMed

    Morsi, Tarek; Hegazy, Rehab; Badawy, Wael

    2017-06-01

    The present study aimed to assess the radiological parameters from gamma rays due to the uncontrolled disposal of porcelain waste to the environment. Qualitative and quantitative identification of radionuclides in the investigated samples was carried out by means of a high-purity germanium (HPGe) detector. The average activity concentrations of the local porcelain samples were measured as 208.28 Bq/kg for 226 Ra, 125.73 Bq/kg for 238 U, 84.94 Bq/kg for 232 Th and 1033.61 Bq/kg for 40 K, respectively. The imported samples had an average activity of 240.57 Bq/kg for 226 Ra, 135.56 Bq/kg for 238 U, 115.74 Bq/kg for 232 Th and 1312.49 Bq/kg for 40 K, respectively. Radiological parameters and the radium equivalent Ra eq for the investigated samples were calculated. The external and internal hazard indices, representative level index (I γ ), alpha index (I α ), and the exemption level (I x ), were estimated to be higher than the recommended value (unity), while the average activity concentrations for the studied samples were higher than recommended levels. In conclusion, we are concerned that disposal of porcelain in the environment might be a significant hazard.

  7. Radiological medical data preservation in the Southern Urals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melamed, E.

    2000-07-01

    Information is being microfilmed and scanned in the Southern Urals to ensure the archival preservation of the unique, important and irreplaceable records documenting chromic low-level radiation exposure to workers and neighboring populations of the Mayak Production Association (MAYAK), as well as health effects. The records include dosimetric and epidemiologic information maintained on workers and neighboring populations located at facilities in Ozyorsk and Chelyabinsk. Microfilming is being done in Ozyorsk, and on a more limited basis in Chelyabinsk, where a scanning project has also recently been initiated. Over 1,800 rolls of film have been produced as of the fall of 1999.more » This article describes the background and results of this data preservation effort and includes brief summary tables describing the types of records being preserved. Researchers interested in access to these records should contact Paul Seligman, Deputy Assistant Secretary for the Office of Health Studies at the Department of Energy (DOE) for more information.« less

  8. Predictors of Relapse in Patients with Organizing Pneumonia

    PubMed Central

    Kim, Minjung; Seo, Hyewon; Shin, Kyung-Min; Lim, Jae-Kwang; Kim, Hyera; Yoo, Seung-Soo; Lee, Jaehee; Lee, Shin-Yup; Kim, Chang-Ho; Park, Jae-Yong

    2015-01-01

    Background Although organizing pneumonia (OP) responds well to corticosteroid therapy, relapse is common during dose reduction or follow-up. Predictors of relapse in OP patients remain to be established. The aim of the present study was to identify factors related to relapse in OP patients. Methods This study was retrospectively performed in a tertiary referral center. Of 66 OP patients who were improved with or without treatment, 20 (30%) experienced relapse. The clinical and radiologic parameters in the relapse patient group (n=20) were compared to that in the non-relapse group (n=46). Results Multivariate analysis demonstrated that percent predicted forced vital capacity (FVC), PaO2/FiO2, and serum protein level were significant predictors of relapse in OP patients (odds ratio [OR], 0.82; 95% confidence interval [CI], 0.70-0.97; p=0.018; OR, 1.02; 95% CI, 1.00-1.04; p=0.042; and OR, 0.06; 95% CI, 0.01-0.87; p=0.039, respectively). Conclusion This study shows that FVC, PaO2/FiO2 and serum protein level at presentation can significantly predict relapse in OP patients. PMID:26175771

  9. Ward nurses' knowledge of computed tomography scanning.

    PubMed

    Majeed, M A; Nayeemuddin, M; Christie, M

    Patients benefit from and are reassured by advance information on procedures that they are to undergo. Ward nurses should have adequate knowledge of radiological investigations to ensure proper patient preparation and good interdepartmental communication to avoid delays and cancellations. This study was conducted to assess the ward nurses' knowledge of the process of computed tomography (CT) scanning. One hundred and twenty qualified nurses were asked to complete a questionnaire regarding CT scanning. The findings revealed a suboptimal level of awareness about the process. This is probably due to lack of formal teaching for nurses on the wards in regards the different radiological procedures and patient preparation. There is a strong case for better educational talks on rapidly changing radiological techniques for ward staff to ensure high-quality patient care.

  10. Trends in Publications in Radiology Journals Designated as Relating to Patient-Centered Care.

    PubMed

    Rosenkrantz, Andrew B; Rawson, James V

    2017-05-01

    To assess trends in publications in radiology journals designated as dealing with patient-centered care. PubMed was searched for articles in radiology journals for which the article's record referenced patient-centered/patient-centric care. Among these, original research articles were identified and assigned major themes. Trends were assessed descriptively. A total of 115 articles in radiology journals designated as dealing with patient-centered care were identified, including 40 original research articles. The number of articles annually ranged from 0 to 4 in 2000-2008, 5 to 9 in 2010-2012, 14 to 15 in 2013-2014, and 25 in 2015. Only four radiology journals had published more than one of the original research articles. Original research articles' most common themes were: optimization of patients' access to reports and images (n=7); patients' examination experience (5); image evaluation (n=4); radiologists meeting with patients (n=4); improving patients' knowledge of imaging (n=3); examination wait times/efficiency (n=3); examination utilization/appropriateness (n=3); and IT enhancements (n=3). A total of 13 of 40 original research articles solicited opinions from patients. One study involved patients in educating trainees regarding patient-centered care. No study involved patients in system-level decisions regarding health care design and delivery. Articles dealing with patient-centered care in radiology are increasing, though they remain concentrated in a limited number of journals. Though major themes included image/report access, patient experiences, and radiologists meeting with patients, many studies dealt with less clearly patient-centric topics such as examination interpretation, while inclusion of patients in systems design was lacking. Further research in radiology is encouraged to target a broader range of ideals of patient-centered care, such as diversity, autonomy, and compassion, and to incorporate greater patient engagement. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. Verification survey report of the south waste tank farm training/test tower and hazardous waste storage lockers at the West Valley demonstration project, West Valley, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weaver, Phyllis C.

    A team from ORAU's Independent Environmental Assessment and Verification Program performed verification survey activities on the South Test Tower and four Hazardous Waste Storage Lockers. Scan data collected by ORAU determined that both the alpha and alpha-plus-beta activity was representative of radiological background conditions. The count rate distribution showed no outliers that would be indicative of alpha or alpha-plus-beta count rates in excess of background. It is the opinion of ORAU that independent verification data collected support the site?s conclusions that the South Tower and Lockers sufficiently meet the site criteria for release to recycle and reuse.

  12. Anniversary Paper: Image processing and manipulation through the pages of Medical Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Armato, Samuel G. III; Ginneken, Bram van; Image Sciences Institute, University Medical Center Utrecht, Heidelberglaan 100, Room Q0S.459, 3584 CX Utrecht

    The language of radiology has gradually evolved from ''the film'' (the foundation of radiology since Wilhelm Roentgen's 1895 discovery of x-rays) to ''the image,'' an electronic manifestation of a radiologic examination that exists within the bits and bytes of a computer. Rather than simply storing and displaying radiologic images in a static manner, the computational power of the computer may be used to enhance a radiologist's ability to visually extract information from the image through image processing and image manipulation algorithms. Image processing tools provide a broad spectrum of opportunities for image enhancement. Gray-level manipulations such as histogram equalization, spatialmore » alterations such as geometric distortion correction, preprocessing operations such as edge enhancement, and enhanced radiography techniques such as temporal subtraction provide powerful methods to improve the diagnostic quality of an image or to enhance structures of interest within an image. Furthermore, these image processing algorithms provide the building blocks of more advanced computer vision methods. The prominent role of medical physicists and the AAPM in the advancement of medical image processing methods, and in the establishment of the ''image'' as the fundamental entity in radiology and radiation oncology, has been captured in 35 volumes of Medical Physics.« less

  13. Assessment of four midcarpal radiologic determinations.

    PubMed

    Cho, Mickey S; Battista, Vincent; Dubin, Norman H; Pirela-Cruz, Miguel

    2006-03-01

    Several radiologic measurement methods have been described for determining static carpal alignment of the wrist. These include the scapholunate, radiolunate, and capitolunate angles. The triangulation method is an alternative radiologic measurement which we believe is easier to use and more reproducible and reliable than the above mentioned methods. The purpose of this study is to assess the intraobserver reproducibility and interobserver reliability of the triangulation method, scapholunate, radiolunate, and capitolunate angles. Twenty orthopaedic residents and staff at varying levels of training made four radiologic measurements including the scapholunate, radiolunate and capitolunate angles as well as the triangulation method on five different lateral, digitized radiographs of the wrist and forearm in neutral radioulnar deviation. Thirty days after the initial measurements, the participants repeated the four radiologic measurements using the same radiographs. The triangulation method had the best intra-and-interobserver agreement of the four methods tested. This agreement was significantly better than the capitolunate and radiolunate angles. The scapholunate angle had the next best intraobserver reproducibility and interobserver reliability. The triangulation method has the best overall observer agreement when compared to the scapholunate, radiolunate, and capitolunate angles in determining static midcarpal alignment. No comment can be made on the validity of the measurements since there is no radiographic gold standard in determining static carpal alignment.

  14. Radioactivity and radiological risk associated with effluent sediment containing technologically enhanced naturally occurring radioactive materials in amang (tin tailings) processing industry.

    PubMed

    Bahari, Ismail; Mohsen, Nasirian; Abdullah, Pauzi

    2007-01-01

    The processing of amang, or tin tailings, for valuable minerals has been shown to technologically enhance NORM and this has stirred significant radiological safety and health concerns among Malaysia's regulatory authority. A growing radiological concern is now focused on the amang effluent containing NORM in recycling ponds, since these ponds may be reclaimed for future residential developments. A study was carried out to assess the radiological risk associated with amang processing and the accumulated effluent in the recycling ponds. Twenty-six sediment samples from the recycling ponds of two amang plants in the states of Selangor and Perak, Malaysia, were collected and analyzed. The maximum activity concentrations of (238)U, (226)Ra, (232)Th and (40)K recorded in sediments from these ponds were higher than Malaysia's and the world's natural highest. Correspondingly, the mean radium equivalent activity concentration indices, Ra(eq), and gamma radiation representative level index, I(gammar), were higher than the world's average. The enhancement of NORM in effluent sediments as a consequence of amang processing, and the use of a closed water management recycling system created Effective Dose Rates, E (nSv h(-1)), that signal potential environmental radiological risks in these ponds, should they be reclaimed for future land use.

  15. E-learning tools for education: regulatory aspects, current applications in radiology and future prospects.

    PubMed

    Pinto, A; Selvaggi, S; Sicignano, G; Vollono, E; Iervolino, L; Amato, F; Molinari, A; Grassi, R

    2008-02-01

    E-learning, an abbreviation of electronic learning, indicates the provision of education and training on the Internet or the World Wide Web. The impact of networks and the Internet on radiology is undoubtedly important, as it is for medicine as a whole. The Internet offers numerous advantages compared with other mass media: it provides access to a large amount of information previously known only to individual specialists; it is flexible, permitting the use of images or video; and it allows linking to Web sites on a specific subject, thus contributing to further expand knowledge. Our purpose is to illustrate the regulatory aspects (including Internet copyright laws), current radiological applications and future prospects of e-learning. Our experience with the installation of an e-learning platform is also presented. We performed a PubMed search on the published literature (without time limits) dealing with e-learning tools and applications in the health sector with specific reference to radiology. The search included all study types in the English language with the following key words: e-learning, education, teaching, online exam, radiology and radiologists. The Fiaso study was referred to for the regulatory aspects of e-learning. The application of e-learning to radiology requires the development of a model that involves selecting and creating e-learning platforms, creating and technologically adapting multimedia teaching modules, creating and managing a unified catalogue of teaching modules, planning training actions, defining training pathways and Continuing Education in Medicine (CME) credits, identifying levels of teaching and technological complexity of support tools, sharing an organisational and methodological model, training the trainers, operators' participation and relational devices, providing training, monitoring progress of the activities, and measuring the effectiveness of training. Since 2004, a platform--LiveLearning--has been used at our university: this is a Web-oriented application, that is, an Internet software solution that users can access through a Web browser. The pages displayed by the browser are dynamically generated through interaction with a database that collects both data required for the application to work and data related to the courses provided. There are different approaches to developing applications that use databases to store information. The selected approach is based on a modular three-level architecture divided into presentation level, intermediate level, and data level. The LiveLearning platform includes modules to manage multimedia contents and to interface with the streaming server so that the student can access the training contents directly from the platform interfaces. Furthermore, the platform offers its users different modules: Teaching Units, Documents, Forums, and Chats. By appropriately combining these modules, customised training can be devised based on specific requirements. The increasing diffusion of continuous education will reduce the costs of e-learning and make this training method, which helps keep pace with technological progress, more attractive, with significant professional gains for radiologists.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noshkin, V. E.; Robison, W. L.

    Between June 1946 and October 1958, Enewetak and Bikini Atolls were used by the United States as testing grounds for 66 nuclear devices. The combined explosive yield from these tests was 107 Mt (Mt TNT equivalents). This testing produced close-in fallout debris that was contaminated with quantities of radioactive fission and particle activated products, and unspent radioactive nuclear fuel that entered the aquatic environment of the atolls. Today, the sediments in the lagoons are reservoirs for 10's of TBq of the transuranics and some long-lived fission and activation products. The larger amounts of contamination are associated with fine and coarsemore » sediment material adjacent to the locations of the high yield explosions. Radionuclides are also distributed vertically in the sediment column to various depths in all regions of the lagoons. Concentrations greater than fallout background levels are found in filtered water sampled over several decades from all locations and depths in the lagoons. This is a direct indication that the radionuclides are continuously mobilized to solution from the solid phases. Of particular importance is the fact that the long-lived radionuclides are accumulated to different levels by indigenous aquatic plants and organisms that are used as food by resident people. One might anticipate finding continuous high contamination levels in many of the edible marine organisms from the lagoons, since the radionuclides associated with the sediments are not contained and are available to the different organisms in a relatively shallow water environment. This is not the case. We estimate that the radiological dose from consumption of the edible parts of marine foods at Enewetak and Bikini is presently about 0.05% of the total 50-year integral effective dose from all other exposure pathways that include ingestion of terrestrial foods and drinking water, external exposure and inhalation. The total radiological dose from the marine pathway is dominated by the natural radionuclides, {sup 210}Po and {sup 210}Pb. Man-made radionuclides presently contribute less than 0.3% of the dose from these natural radionuclides in the marine food chain.« less

  17. Natural radioactivity in surface soil samples from dwelling areas in Tehran city, Iran.

    PubMed

    Asgharizadeh, F; Ghannadi, M; Samani, A B; Meftahi, M; Shalibayk, M; Sahafipour, S A; Gooya, E S

    2013-09-01

    The study was carried out to determine radioactivity concentrations in surface soil samples of the city of Tehran and associated potential radiological hazards. The natural radionuclide ((226)Ra, (232)Th and (40)K) contents were determined for 50 locations throughout the geological surface formations in a representative area in the city of Tehran, Iran, using high-resolution gamma-spectrometric analysis. The range of activity concentrations of (226)Ra, (232)Th and (40)K in the soil from the studied areas varies from 30.5±0.6 to 45.4±0.9, 27.3±0.5 to 57.1±1.1 and 328.0±4.6 to 768.5±13.4 Bq kg(-1) with overall mean values of 38.8±0.7, 43.4±0.8 and 555.1±8.9 Bq kg(-1), respectively. The mean radium equivalent activity, external hazard index, internal hazard index to quantify the internal exposure to radon and its daughter products, as well as the gamma activity concentration index for each sample are 143.6±4.6 Bq kg(-1), 0.39, 0.49 and 0.53, respectively. The average estimated radium equivalent is comparable with reported values for many countries in the world. Therefore, these areas may not pose radiological risks to the inhabitants due to harmful effects of the ionising radiation from the natural radioactivity in soil. The calculated average external and internal hazard indexes were found to be less than unity, as a recommended safe level. Estimates of the measured radionuclide content have been made for calculating the absorbed dose rate in the outdoor air at 1 m above the ground level. The absorbed dose rates resulting from those concentrations ranged from 48.1 to 88.7 nGy h(-1). Assuming a 20 % occupancy factor proposed by UNSCEAR, 2000, the corresponding effective dose rates in outdoor air equivalent to the population were calculated to be between 0.06 and 0.11 mSv y(-1). The measurement results and calculated values obtained from this study indicate that the dwelling areas in Tehran city, Iran, have background radioactivity levels within natural limits.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Virginia Finley

    The results of the 1999 environmental surveillance and monitoring program for the Princeton Plasma Physics Laboratory (PPPL) are presented and discussed. The purpose of this report is to provide the U.S. Department of Energy and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of PPPL's operations. The report also summarizes environmental initiatives, assessments, and programs that were undertaken in 1999. The Princeton Plasma Physics Laboratory has engaged in fusion energy research since 1951. The long-range goal of the U.S. Magnetic Fusion Energy Research Program ismore » to create innovations to make fusion power a practical reality--an alternative energy source. 1999 marked the first year of National Spherical Torus Experiment (NSTX) operations and Tokamak Fusion Test Reactor (TFTR) dismantlement and deconstruction activities. A collaboration among fourteen national laboratories, universities, and research institutions, the NSTX is a major element in the U.S. Fusion Energy Sciences Program. It has been designed to test the physics principles of spherical torus (ST) plasmas. The ST concept could play an important role in the development of smaller, more economical fusion reactors. With its completion within budget and ahead of its target schedule, NSTX first plasma occurred on February 12, 1999. The 1999 performance of the Princeton Plasma Physics Laboratory was rated ''outstanding'' by the U.S. Department of Energy in the Laboratory Appraisal report issued early in 2000. The report cited the Laboratory's consistently excellent scientific and technological achievements, its successful management practices, and included high marks in a host of other areas including environmental management, employee health and safety, human resources administration, science education, and communications. Groundwater investigations continued under a voluntary agreement with the New Jersey Department of Environmental Protection. PPPL monitored for the presence of non-radiological contaminants, mainly volatile organic compounds (components of degreasing solvents). Monitoring revealed the presence of low levels of volatile organic compounds in an area adjacent to PPPL. Also, PPPL's radiological monitoring program characterized the ambient, background levels of tritium in the environment and from the TFTR stack; the data are presented in this report.« less

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finley, V.L. and Levine, J.D.

    The results of the 1997 environmental surveillance and monitoring program for the Princeton Plasma Physics Laboratory (PPPL) are presented and discussed. The purpose of this report is to provide the U.S. Department of Energy and the public with information on the level of radioactive and non-radioactive pollutants, if any, that are added to the environment as a result of PPPL's operations. During Calendar Year 1997, PPPL's Tokamak Fusion Test Reactor (TFTR) completed fifteen years of fusion experiments begun in 1982. Over the course of three and half years of deuterium-tritium (D-T) plasma experiments, PPPL set a world record of 10.7more » million watts of controlled fusion power, more than 700 tritium shots pulsed into the reactor vessel generating more than 5.6 x 10 20 neutron and 1.6 gigajoules of fusion energy and researchers studied plasma science experimental data, which included "enhanced reverse shear techniques." As TFTR was completing its historic operations, PPPL participated with the Oak Ridge National Laboratory, Columbia University, and the University of Washington (Seattle) in a collaboration effort to design the National Spherical Torus Experiment (NSTX). This next device, NSTX, is located in the former TFTR Hot Cell on D site, and it is designed to be a smaller and more economical torus fusion reactor. Construction of this device began in late 1997, and first plasma in scheduled for early 1999. For 1997, the U.S. Department of Energy in its Laboratory Appraisal report rated the overall performance of Princeton Plasma Physics Laboratory as "excellent." The report cited the Laboratory's consistently excellent scientific and technological achievements and its successful management practices, which included high marks for environmental management, employee health and safety, human resources administration, science education, and communications. Groundwater investigations continued under a voluntary agreement with the New Jersey Department of Environmental Protection. PPPL monitored the presence of non-radiological contaminants, mainly volatile organic compounds (components of degreasing solvents). Monitoring revealed the presence of low levels of volatile organic compounds in an adjacent area to PPPL. Also, PPPL's radiological monitoring program characterized the ambient, background levels of tritium in the environment and from the TFTR stack; the data are presented in this report.« less

  20. Role of light and heavy minerals on natural radioactivity level of high background radiation area, Kerala, India.

    PubMed

    Ramasamy, V; Sundarrajan, M; Suresh, G; Paramasivam, K; Meenakshisundaram, V

    2014-02-01

    Natural radionuclides ((238)U, (232)Th and (40)K) concentrations and eight different radiological parameters have been analyzed for the beach sediments of Kerala with an aim of evaluating the radiation hazards. Activity concentrations ((238)U and (232)Th) and all the radiological parameters in most of the sites have higher values than recommended values. The Kerala beach sediments pose significant radiological threat to the people living in the area and tourists going to the beaches for recreation or to the sailors and fishermen involved in their activities in the study area. In order to know the light mineral characterization of the present sediments, mineralogical analysis has been carried out using Fourier transform infrared (FTIR) spectroscopic technique. The eight different minerals are identified and they are characterized. Among the various observed minerals, the minerals such as quartz, microcline feldspar, kaolinite and calcite are major minerals. The relative distribution of major minerals is determined by calculating extinction co-efficient and the values show that the amount of quartz is higher than calcite and much higher than microcline feldspar. Crystallinity index is calculated to know the crystalline nature of quartz present in the sediments. Heavy mineral separation analysis has been carried out to know the total heavy mineral (THM) percentage. This analysis revealed the presence of nine heavy minerals. The minerals such as monazite, zircon, magnetite and illmenite are predominant. Due to the rapid and extreme changes occur in highly dynamic environments of sandy beaches, quantities of major light and heavy minerals are widely varied from site to site. Granulometric analysis shows that the sand is major content. Multivariate statistical (Pearson correlation, cluster and factor) analysis has been carried out to know the effect of mineralogy on radionuclide concentrations. The present study concluded that heavy minerals induce the (238)U and (232)Th concentrations. Whereas, light mineral (calcite) controls the (40)K concentration. In addition to the heavy minerals, clay content also induces the important radioactive variables. © 2013 Published by Elsevier Ltd.

  1. Varying performance in mammographic interpretation across two countries: Do results indicate reader or population variances?

    NASA Astrophysics Data System (ADS)

    Soh, BaoLin P.; Lee, Warwick B.; Wong, Jill; Sim, Llewellyn; Hillis, Stephen L.; Tapia, Kriscia A.; Brennan, Patrick C.

    2016-03-01

    Aim: To compare the performance of Australian and Singapore breast readers interpreting a single test-set that consisted of mammographic examinations collected from the Australian population. Background: In the teleradiology era, breast readers are interpreting mammographic examinations from different populations. The question arises whether two groups of readers with similar training backgrounds, demonstrate the same level of performance when presented with a population familiar only to one of the groups. Methods: Fifty-three Australian and 15 Singaporean breast radiologists participated in this study. All radiologists were trained in mammogram interpretation and had a median of 9 and 15 years of experience in reading mammograms respectively. Each reader interpreted the same BREAST test-set consisting of sixty de-identified mammographic examinations arising from an Australian population. Performance parameters including JAFROC, ROC, case sensitivity as well as specificity were compared between Australian and Singaporean readers using a Mann Whitney U test. Results: A significant difference (P=0.036) was demonstrated between the JAFROC scores of the Australian and Singaporean breast radiologists. No other significant differences were observed. Conclusion: JAFROC scores for Australian radiologists were higher than those obtained by the Singaporean counterparts. Whilst it is tempting to suggest this is down to reader expertise, this may be a simplistic explanation considering the very similar training and audit backgrounds of the two populations of radiologists. The influence of reading images that are different from those that radiologists normally encounter cannot be ruled out and requires further investigation, particularly in the light of increasing international outsourcing of radiologic reporting.

  2. Placement of central venous port catheters and peripherally inserted central catheters in the routine clinical setting of a radiology department: analysis of costs and intervention duration learning curve.

    PubMed

    Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H

    2017-12-01

    Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.

  3. Does improved access to diagnostic imaging results reduce hospital length of stay? A retrospective study

    PubMed Central

    2010-01-01

    Background One year after the introduction of Information and Communication Technology (ICT) to support diagnostic imaging at our hospital, clinicians had faster and better access to radiology reports and images; direct access to Computed Tomography (CT) reports in the Electronic Medical Record (EMR) was particularly popular. The objective of this study was to determine whether improvements in radiology reporting and clinical access to diagnostic imaging information one year after the ICT introduction were associated with a reduction in the length of patients' hospital stays (LOS). Methods Data describing hospital stays and diagnostic imaging were collected retrospectively from the EMR during periods of equal duration before and one year after the introduction of ICT. The post-ICT period was chosen because of the documented improvement in clinical access to radiology results during that period. The data set was randomly split into an exploratory part used to establish the hypotheses, and a confirmatory part. The data was used to compare the pre-ICT and post-ICT status, but also to compare differences between groups. Results There was no general reduction in LOS one year after ICT introduction. However, there was a 25% reduction for one group - patients with CT scans. This group was heterogeneous, covering 445 different primary discharge diagnoses. Analyses of subgroups were performed to reduce the impact of this divergence. Conclusion Our results did not indicate that improved access to radiology results reduced the patients' LOS. There was, however, a significant reduction in LOS for patients undergoing CT scans. Given the clinicians' interest in CT reports and the results of the subgroup analyses, it is likely that improved access to CT reports contributed to this reduction. PMID:20819224

  4. Tuberculosis of the hip in children: A retrospective analysis of 27 patients

    PubMed Central

    Agarwal, Anil; Suri, Tarun; Verma, Indereshwar; Kumar, Shashi Kant; Gupta, Neeraj; Shaharyar, Abbas

    2014-01-01

    Background: We retrospectively evaluated the pretreatment radiological presentation and the clinicoradiological outcome at the completion of 1 year chemotherapy in osteoarticular tuberculosis of hip in children to prognosticate correlation between them. Materials and Methods: We retrospectively analyzed the clinical and plain radiographic findings in 27 patients with an age of 12 years or younger in whom hip tuberculosis was diagnosed and treated between 2006 and 2010. The diagnosis was based on histopathology in 14 and clinicoradiological basis in 13 patients. The pre and post treatment plain radiographs were evaluated according to Shanmugasundaram radiological classification and our observations regarding unclassified cases which were not fit in this classification were suggested. The functional outcome at the completion of chemotherapy was assessed using modified Moon's criteria. Results: The male female ratio was 11:16. The left hip was involved more frequently than the right (17:10). The average age was 7.37 years (range, 2-12 years). In the pretreatment radiographs, 9 hips were normal, 6 traveling, 4 dislocating, 1 protrusio acetabuli, 3 atrophic and 4 unclassified types (3 triradiate; 1 pseudarthrosis coxae). There were no Perthes and mortar pestle at the initial presentation. Posttreatment, the types changed to 9 normal, 3 Perthes, 1 protrusio acetabuli, 1 atrophic, 4 mortar pestle and 9 unclassified types (3 triradiate, 3 pseudarthrosis coxae and 3 ankylosed). There were 37% excellent, 18.5% good, 26% fair and 18.5% poor results. The prognosis was best with initial “triradiate” and normal types and worst with posttreatment atrophic and “ankylosed” types. Conclusions: The Shanmugasundaram radiological types accurately predict prognosis only in normal types and “triradiate” pattern. The functional outcome is independent of radiological morphology of the hip in smaller children. PMID:25298552

  5. Radiological progression and its predictive risk factors in silicosis

    PubMed Central

    Lee, H; Phoon, W; Ng, T

    2001-01-01

    OBJECTIVES—To investigate the risk factors predicting radiological progression in silicosis in a prospective cohort study of patients with silicosis who were previously exposed to silica from granite dust.
METHODS—From among a total of 260 patients with silicosis contracted from granite work, 141 with available serial chest x ray films of acceptable quality taken over a period of 2 to 17 (mean 7.5) years, were selected for study. Ninety four (66.7%) had ended exposure 5 or more years perviously (mean 10.1 years, maximum 28 years). Radiological progression was assessed by paired comparison of the initial and most recent radiographs, with two or more steps of increase in profusion of small opacities according to the 12 point scale of the International Labour Organisation (ILO) classification of radiographs of pneumoconiosis, taken from the majority reading by a panel of three independent readers.
RESULTS—Overall, 37% of patients with silicosis had radiological evidence of progression. From the initial radiographs, 24 (31.6%) of those with radiological profusion category 1, 15 (37.5%) of those with radiological profusion category 2, and 13 (52%) of those with complicated silicosis (including all seven with category 3 profusion of small opacities) showed radiological progression. As expected, progression was more likely to be found after longer periods of follow up (the interval between the two chest x ray films) with a 20% increased odds of progression for every additional year of follow up. After adjustment for varying intervals of follow up, the probability of radiological progression was found to be significant if large opacities were present in the initial chest x ray film. Progression was also less likely to be found among those who had ended exposure to silica longer ago, although the result was of borderline significance (p=0.07). Tuberculosis was also associated with increased likelihood of progression (borderline significance).
CONCLUSIONS—There is a high probability of radiological progression in silicosis after high levels of exposure to granite dust among workers who were followed up for up to 17 years. A significant risk factor is the extent of radiological opacities in the initial chest x ray film. The probability of progression is also likely to be reduced with longer periods after the end of exposure.


Keywords: silicosis; radiological progression; granite quarry PMID:11404452

  6. Methods for Probabilistic Radiological Dose Assessment at a High-Level Radioactive Waste Repository.

    NASA Astrophysics Data System (ADS)

    Maheras, Steven James

    Methods were developed to assess and evaluate the uncertainty in offsite and onsite radiological dose at a high-level radioactive waste repository to show reasonable assurance that compliance with applicable regulatory requirements will be achieved. Uncertainty in offsite dose was assessed by employing a stochastic precode in conjunction with Monte Carlo simulation using an offsite radiological dose assessment code. Uncertainty in onsite dose was assessed by employing a discrete-event simulation model of repository operations in conjunction with an occupational radiological dose assessment model. Complementary cumulative distribution functions of offsite and onsite dose were used to illustrate reasonable assurance. Offsite dose analyses were performed for iodine -129, cesium-137, strontium-90, and plutonium-239. Complementary cumulative distribution functions of offsite dose were constructed; offsite dose was lognormally distributed with a two order of magnitude range. However, plutonium-239 results were not lognormally distributed and exhibited less than one order of magnitude range. Onsite dose analyses were performed for the preliminary inspection, receiving and handling, and the underground areas of the repository. Complementary cumulative distribution functions of onsite dose were constructed and exhibited less than one order of magnitude range. A preliminary sensitivity analysis of the receiving and handling areas was conducted using a regression metamodel. Sensitivity coefficients and partial correlation coefficients were used as measures of sensitivity. Model output was most sensitive to parameters related to cask handling operations. Model output showed little sensitivity to parameters related to cask inspections.

  7. Feasibility of a semiconductor dosimeter to monitor skin dose in interventional radiology.

    PubMed

    Meyer, P; Regal, R; Jung, M; Siffert, P; Mertz, L; Constantinesco, A

    2001-10-01

    The design and preliminary test results of a semiconductor silicon dosimeter are presented in this article. Use of this dosimeter is foreseen for real-time skin dose control in interventional radiology. The strong energy dependence of this kind of radiation detector is well overcome by filtering the silicon diode. Here, the optimal filter features have been calculated by numerical Monte Carlo simulations. A prototype has been built and tested in a radiological facility. The first experimental results show a good match between the filtered semiconductor diode response and an ionization chamber response, within 2% fluctuation in a 2.2 to 4.1 mm Al half-value layer (HVL) energy range. Moreover, the semiconductor sensor response is linear from 0.02 Gy/min to at least 6.5 Gy/min, covering the whole dose rate range found in interventional radiology. The results show that a semiconductor dosimeter could be used to monitor skin dose during the majority of procedures using x-rays below 150 keV. The use of this device may assist in avoiding radiation-induced skin injuries and lower radiation levels during interventional procedures.

  8. Radiological reporting that combine continuous speech recognition with error correction by transcriptionists.

    PubMed

    Ichikawa, Tamaki; Kitanosono, Takashi; Koizumi, Jun; Ogushi, Yoichi; Tanaka, Osamu; Endo, Jun; Hashimoto, Takeshi; Kawada, Shuichi; Saito, Midori; Kobayashi, Makiko; Imai, Yutaka

    2007-12-20

    We evaluated the usefulness of radiological reporting that combines continuous speech recognition (CSR) and error correction by transcriptionists. Four transcriptionists (two with more than 10 years' and two with less than 3 months' transcription experience) listened to the same 100 dictation files and created radiological reports using conventional transcription and a method that combined CSR with manual error correction by the transcriptionists. We compared the 2 groups using the 2 methods for accuracy and report creation time and evaluated the transcriptionists' inter-personal dependence on accuracy rate and report creation time. We used a CSR system that did not require the training of the system to recognize the user's voice. We observed no significant difference in accuracy between the 2 groups and 2 methods that we tested, though transcriptionists with greater experience transcribed faster than those with less experience using conventional transcription. Using the combined method, error correction speed was not significantly different between two groups of transcriptionists with different levels of experience. Combining CSR and manual error correction by transcriptionists enabled convenient and accurate radiological reporting.

  9. Assessing the radiological load on the environment in the middle Danube river basin on the basis of a study of the Kopački Rit Nature Park, Croatia.

    PubMed

    Petrinec, Branko; Sovilj, Marina Poje; Babić, Dinko; Meštrović, Tomislav; Miklavčić, Igor; Radolić, Vanja; Stanić, Denis; Vuković, Branko; Šoštarić, Marko

    2018-06-05

    A study of the environmental radioactivity in the Kopački Rit Nature Park, Croatia, is presented. This wildlife reserve is part of the Middle Danube River Basin, and it is exposed to various pollutants due to a number of human activities in the surroundings, where there is a nuclear power plant and also urban centres and areas of intense agricultural production. Results for the activity concentrations of soil and surface water samples do not indicate any elevated radioactivity level, which is confirmed by on-site measurements of ambient dose rate equivalent. An assessment of the radiological load on the local biota, carried out using the ERICA tool, implies an overall low radiological risk even if conservative values of the risk quotient are used. Therefore, human activities do not have a significant effect on the radiological load on the Kopački Rit area. A similar conclusion might be made with regard to numerous similar environments in the Middle Danube River Basin.

  10. Strategic planning in diagnostic imaging: meeting the challenge.

    PubMed

    Lexa, Frank J

    2008-02-01

    The 21st century has raised new and significant challenges to the practice of diagnostic imaging. Radiologists will have to navigate a difficult path as they face threats from disruptive technologies, adverse demographic changes, pressures to limit reimbursement both from the public and from the private sectors, increased domestic and crossborder competition, and many others. Success in these trying times will require greater attention to strategic planning if we are to thrive and survive in radiology. Strategic planning and tactical implementation methodologies were reviewed, from Sun Tzu to the present day, for applicability to the needs of modern radiology groups. A framework for developing and implementing strategic plans was constructed to assist radiology leaders and groups in considering the spectrum of tasks, from gathering intelligence, to developing scenarios, to implementing and evaluating tactical plans. Strategy and tactics are too important to be ignored or left to others. They need to be core activities for all radiology leaders. Frameworks can be used to help in providing structure and rigour to strategic planning efforts at the department and group level.

  11. Radiation exposure levels within timber industries in Calabar, Nigeria

    PubMed Central

    Inyang, S. O.; Inyang, I. S.; Egbe, N. O.

    2009-01-01

    The UNSCEAR (2000) observed that there could be some exposure at work which would require regulatory control but is not really considered. This study was, therefore, set up to evaluate the effective dose in timber industries in Calabar, Nigeria to determine if the evaluated dose levels could lead to any radiological health effect in the workers, and also determine if the industries require regulatory control. The gamma ray exposure at four timber industries measured using an exposure meter were converted to effective dose and compared with the public and occupational values. The evaluated effective dose values in the timber industries were below public and occupational exposure limits and may not necessarily result in any radiological health hazard. Therefore, they may not require regulatory control. PMID:20098544

  12. Radiological image presentation requires consideration of human adaptation characteristics

    NASA Astrophysics Data System (ADS)

    O'Connell, N. M.; Toomey, R. J.; McEntee, M.; Ryan, J.; Stowe, J.; Adams, A.; Brennan, P. C.

    2008-03-01

    Visualisation of anatomical or pathological image data is highly dependent on the eye's ability to discriminate between image brightnesses and this is best achieved when these data are presented to the viewer at luminance levels to which the eye is adapted. Current ambient light recommendations are often linked to overall monitor luminance but this relies on specific regions of interest matching overall monitor brightness. The current work investigates the luminances of specific regions of interest within three image-types: postero-anterior (PA) chest; PA wrist; computerised tomography (CT) of the head. Luminance levels were measured within the hilar region and peripheral lung distal radius and supra-ventricular grey matter. For each image type average monitor luminances were calculated with a calibrated photometer at ambient light levels of 0, 100 and 400 lux. Thirty samples of each image-type were employed, resulting in a total of over 6,000 measurements. Results demonstrate that average monitor luminances varied from clinically-significant values by up to a factor of 4, 2 and 6 for chest, wrist and CT head images respectively. Values for the thoracic hilum and wrist were higher and for the peripheral lung and CT brain lower than overall monitor levels. The ambient light level had no impact on the results. The results demonstrate that clinically important radiological information for common radiological examinations is not being presented to the viewer in a way that facilitates optimised visual adaptation and subsequent interpretation. The importance of image-processing algorithms focussing on clinically-significant anatomical regions instead of radiographic projections is highlighted.

  13. Polyurethane on titanium unconstrained disc arthroplasty versus anterior discectomy and fusion for the treatment of cervical disc disease: a review of level I-II randomized clinical trials including clinical outcomes.

    PubMed

    Aragonés, María; Hevia, Eduardo; Barrios, Carlos

    2015-12-01

    To contrast the clinical and radiologic outcomes and adverse events of anterior cervical discectomy and fusion (ACDF) with a single cervical disc arthroplasty design, the polyurethane on titanium unconstrained cervical disc (PTUCD). This is a systematic review of randomized clinical trials (RCT) with evidence level I-II reporting clinical outcomes. After a search on different databases including PubMed, Cochrane Central Register of Controlled Trials, and Ovid MEDLINE, a total of 10 RCTs out of 51 studies found were entered in the study. RTCs were searched from the earliest available records in 2005 to November 2014. Out of a total of 1101 patients, 562 were randomly assigned into the PTUCD arthroplasty group and 539 into the ACDF group. The mean follow-up was 30.9 months. Patients undergoing arthroplasty had lower Neck Disability Index, and better SF-36 Physical component scores than ACDF patients. Patients with PTUCD arthroplasty had also less radiological degenerative changes at the upper adjacent level. Overall adverse events were twice more frequent in patients with ACDF. The rate of revision surgery including both adjacent and index level was slightly higher in patients with ACDF, showing no statistically significant difference. According to this review, PTUCD arthroplasty showed a global superiority to ACDF in clinical outcomes. The impact of both surgical techniques on the cervical spine (radiological spine deterioration and/or complications) was more severe in patients undergoing ACDF. However, the rate of revision surgeries at any cervical level was equivalent for ACDF and PTUCD arthroplasty.

  14. Congenital radioulnar synostosis – case report

    PubMed Central

    Siemianowicz, Anna; Wawrzynek, Wojciech; Besler, Krzysztof

    2010-01-01

    Summary Background: Congenital radioulnar synostosis is a rare malformation of the upper limb, with functional limitations of the limb. Case Report: A 10-year-old child with pain and restricted mobility of the elbow joint was admitted to the hospital. Plain film radiography and CT examination was performed. Radiological examinations showed a congenital radioulnar synostosis. The child underwent surgical treatment – derotational osteotomy. Conclusions: Diagnostic imaging including computed tomography with three-dimentional (3D) reconstructions, preceding surgery enables planning of the surgical treatment. PMID:22802806

  15. A CONCEPTUAL FRAMEWORK FOR MANAGING RADIATION DOSE TO PATIENTS IN DIAGNOSTIC RADIOLOGY USING REFERENCE DOSE LEVELS.

    PubMed

    Almén, Anja; Båth, Magnus

    2016-06-01

    The overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined. The outset of the optimisation process is four stages: providing equipment, establishing methodology, performing examinations and ensuring quality. The optimisation process comprises a series of activities and actions at these stages. The current system of diagnostic reference levels is an activity in the last stage, ensuring quality. The system becomes a reactive activity only to a certain extent engaging the core activity in the radiology department, performing examinations. Three reference dose levels-possible, expected and established-were assigned to the three stages in the optimisation process, excluding ensuring quality. A reasonably achievable dose range is also derived, indicating an acceptable deviation from the established dose level. A reasonable radiation dose for a single patient is within this range. The suggested framework for managing radiation dose should be regarded as one part of the optimisation process. The optimisation process constitutes a variety of complementary activities, where managing radiation dose is only one part. This emphasises the need to take a holistic approach integrating the optimisation process in different clinical activities. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. A comparison of independently conducted dose assessments to determine compliance and resettlement options for the people of Rongelap Atoll.

    PubMed

    Simon, S L; Robison, W L; Thorne, M C; Toburen, L H; Franke, B; Baverstock, K F; Pettingill, H J

    1997-07-01

    Rongelap Island was the home of Marshallese people numbering less than 120 in 1954; 67 were on the island and severely exposed to radioactive fallout from an atomic weapons test in March of that year. Those resident on Rongelap were evacuated 50 h after the test, returned 3 y later, then voluntarily left their home island in 1985 due to their ongoing fear of radiation exposure from residual radioactive contamination. Following international negotiations in 1991, a Memorandum of Understanding (MOU) was signed in early 1992 between the Republic of the Marshall Islands Government, the Rongelap Atoll Local Government, the U.S. Department of Energy, and the U.S. Department of the Interior. In this MOU it was agreed that the Republic of the Marshall Islands, with the aid of the U.S. Department of Energy, would carry out independent dose assessments for the purpose of assisting and advising the Rongelap community on radiological issues related to a safe resettlement of Rongelap. The MOU enacted two action levels which were agreed to be used to establish whether mitigation should be considered as a condition for resettlement of Rongelap Island: (1) no individual should receive an annual dose in the future of 1 mSv or more, above that from natural background radiation, assuming that his/her diet consists of only locally produced foods, and (2) the total surface soil concentration of plutonium and other transuranic elements must be less than 629 Bq kg(-1) (averaged over the top 5 cm). Environmental radiological data and dietary information were collected over two years (1992-1993) for the purpose of predicting future potential doses to Rongelapese who might resettle. In 1994, four independent assessments were reported, including one from each of the following entities: Marshall Islands Nationwide Radiological Study; Lawrence Livermore National Laboratory; an independent advisor from the United Kingdom (MCT); and a committee of the National Research Council. All four assessments concluded that possibly more than 25% of the adult population could exceed the 1 mSv y(-1) dose level based on strict utilization of a local food diet. The purpose of this report is to summarize the methodology, assumptions, and findings from each of four assessments; to summarize the recommendations related to mitigation and resettlement options; to discuss unique programmatic aspects of the study; and to consider the implications of the findings to the future of the Rongelap people.

  17. Radiology system evolution in the new millennium.

    PubMed

    Nauert, R C

    2001-01-01

    For many decades the practice of radiology grew slowly in America and was largely a secondary function under the control of hospitals. In more recent times it has vastly expanded its array of diagnostic, interventional, and therapeutic abilities. There is increasing consumer logic for direct access. Motivations have grown to create large independent entities with broadly diverse capabilities in order to succeed in the new millennium. Most regional markets are evolving rapidly in terms of managed care penetration, health system formation, physician practice consolidation and aggressive purchaser behavior by employers and consumers. To understand the enormity of healthcare evolution, it is useful to look at the industry's paradigm shifts in recent decades. Virtually every aspect of organizational infrastructure, delivery approaches, and the business environment has evolved markedly during the past fifty years. These changes will accelerate. To succeed financially, radiology groups must strengthen their market positions, technical capabilities, continuums of care and geographic dominance. Equally important is the wisdom of diversifying incomes into related services and businesses that provide additional related revenues. Key factors for successful development include facility market growth, full coverage of managed care contracts, high efficiency and aggressive diversification. A fully evolved system generates significant revenues and profitability by protecting and strengthening its financial position in this environment. That is accomplished through the development of strategically located radiology groups, aggressive alliances with medical practices in allied disciplines, and managed radiology departments and facilities for partner health systems. Organizational success ultimately depends on the ability to accept capitated payments under risk-bearing arrangements. The strategic business plan should be organized with the appropriate levels of detail needed to establish executive focus and priorities. These should be woven into operational and capital budgets to reflect expectations of the revenues, expenses and investments tied to the plan. While formidable, all of these objectives are realistic and can be accomplished if the right decisions are made. Initially, the entity's principle business objective is to formulate and begin implementation of methodical yet aggressive strategies for growth that are sensitive to sustaining high levels of quality patient care. The next phase features mergers with large, independent radiology practices in key geographic areas and successful acquisition of smaller practices. The objective of the final phase is to aggressively expand into select metropolitan areas with regional coverage and full teleradiology capabilities. High levels of market strength and financial performance are necessary to succeed. Passive limitations to small geographic areas and narrow practices will undermine their market position and dissolve financial strength with no hope of recovery. Only the dominant systems will survive and prosper.

  18. Skin decontamination cream for radiological contaminants: Formulation development and evaluation

    PubMed Central

    Khan, Abdul Wadood; Kotta, Sabna; Rana, Sudha; Ansari, Shahid Husain; Sharma, Rakesh Kumar; Ali, Javed

    2013-01-01

    Background: Increased use of the radioactive materials in the field of research, medical, nuclear power plant, and industry has increased the risk of accidental exposure. Intentional use of the radioisotopes by terrorist organizations could cause exposure/contamination of a number of the population. In view of the accidental contamination, there is a need to develop self-usable decontamination formulations that could be used immediately after contamination is suspected. Materials and Methods: Present work was planned to optimize and develop self-usable radiation decontamination cream formulation. Various pharmaceutical parameters were characterized. 99mTc-sodium pertechnetate was used as radiocontaminant. Static counts were recorded before and after decontamination using single photon emission computed tomography. Results: Decontamination efficacy of the cream was found to be 42% ± 3% at 0-0.5 h after the exposure. Primary skin irritancy test was satisfactory as no erythema or edema was observed visually after 2 weeks of the formulation application. Conclusion: The decontamination studies proved the potential of EDTA to remove the radiological contaminants effectively. PMID:23799206

  19. Radiology workstation for mammography: preliminary observations, eyetracker studies, and design

    NASA Astrophysics Data System (ADS)

    Beard, David V.; Johnston, Richard E.; Pisano, Etta D.; Hemminger, Bradley M.; Pizer, Stephen M.

    1991-07-01

    For the last four years, the UNC FilmPlane project has focused on constructing a radiology workstation facilitating CT interpretations equivalent to those with film and viewbox. Interpretation of multiple CT studies was originally chosen because handling such large numbers of images was considered to be one of the most difficult tasks that could be performed with a workstation. The authors extend the FilmPlane design to address mammography. The high resolution and contrast demands coupled with the number of images often cross- compared make mammography a difficult challenge for the workstation designer. This paper presents the results of preliminary work with workstation interpretation of mammography. Background material is presented to justify why the authors believe electronic mammographic workstations could improve health care delivery. The results of several observation sessions and a preliminary eyetracker study of multiple-study mammography interpretations are described. Finally, tentative conclusions of what a mammographic workstation might look like and how it would meet clinical demand to be effective are presented.

  20. Neurodegeneration and Mirror Image Agnosia

    PubMed Central

    Chandra, Sadanandavalli Retnaswami; Issac, Thomas Gregor

    2014-01-01

    Background: Normal Percept with abnormal meaning (Agnosias) has been described from nineteenth century onwards. Later literature became abundant with information on the spectrum of Prosopagnosias. However, selective difficulty in identifying reflected self images with relatively better cognitive functions leads to problems in differentiating it from non-organic psychosis. Aim: In the present study, we investigated patients with dementia who showed difficulty in identifying reflected self images while they were being tested for problems in gnosis with reference to identification of reflected objects, animals, relatives, and themselves and correlate with neuropsychological and radiological parameters. Patients and Methods: Five such patients were identified and tested with a 45 cm × 45 cm mirror kept at 30-cm distance straight ahead of them. Results: Mirror image agnosia is seen in patients with moderate stage posterior dementias who showed neuropsychological and radiological evidence of right parietal dysfunction. Conclusion: Interpretation of reflected self images perception in real time probably involves distinct data-linking circuits in the right parietal lobe, which may get disrupted early in the course of the disease. PMID:25317393

  1. The role of the biomedical physicist in the education of the healthcare professions: an EFOMP project.

    PubMed

    Caruana, C J; Wasilewska-Radwanska, M; Aurengo, A; Dendy, P P; Karenauskaite, V; Malisan, M R; Meijer, J H; Mornstein, V; Rokita, E; Vano, E; Wucherer, M

    2009-09-01

    The role of the biomedical physicist in the education of the healthcare professions has not yet been studied in a systematic manner. This article presents the first results of an EFOMP project aimed at researching and developing this important component of the role of the biomedical physicist. A background to the study expands on the reasons that led to the need for the project. This is followed by an extensive review of the published literature regarding the role. This focuses mainly on the teaching contributions within programmes for physicians, diagnostic radiographers, radiation therapists, and the postgraduate medical specializations of radiology, radiotherapy, interventional radiology and cardiology. Finally a summary list of the specific research objectives that need to be immediately addressed is presented. These are the carrying out of a Europe-wide position audit for the role, the construction of a strategic role development model and the design of a curriculum development model suitable for modern healthcare professional education.

  2. Hydroxyapatite crystals as a bone graft substitute in benign lytic lesions of bone

    PubMed Central

    Gupta, Anil Kumar; Kumar, Praganesh; Keshav, Kumar; Singh, Anant

    2015-01-01

    Background: Bone grafts are required to fill a cavity created after curettage of benign lytic lesions of the bone. To avoid the problems associated at donor site with autologous bone graft, we require allograft or bone graft substitutes. We evaluated the healing of lytic lesions after hydroxyapatite (HA) grafting by serial radiographs. Materials and Methods: Forty cases of benign lytic lesions of bone were managed by simple curettage and grafting using HA blocks. Commercially available HA of bovine origin (Surgiwear Ltd., Shahjahanpur, India) was used for this purpose. Mean duration of followup was 34.8 months (range 12–84 months). Mean patient age was 19.05 years (range 3–55 years). Radiological staging of graft incorporation was done as per criteria of Irwin et al. 2001. Results: In our series, two cases were in stage I. A total of 11 cases were in stage II and 27 were in stage III. Graft incorporation was radiologically complete by 15 months. Clinical recovery was observed before radiological healing. The average time taken to return to preoperative function was 3 months. Recurrence was observed in giant cell tumor (n = 3) and chondromyxoid fibroma (n = 1). There was no incidence of graft rejection, collapse, growth plate disturbances or antigenic response. Conclusions: We conclude that calcium HA is biologically acceptable bone graft substitute in the management of benign lytic lesions of bone. PMID:26806973

  3. Emergency communication and information issues in terrorist events involving radioactive materials.

    PubMed

    Becker, Steven M

    2004-01-01

    With the threat posed by terrorism involving radioactive materials now high on the nation's agenda, local, state, and federal agencies are moving to enhance preparedness and response capabilities. Crucial to these efforts is the development of effective risk communication strategies. This article reports findings from an ongoing study of risk communication issues in nuclear/radiological terrorism situations. It is part of a larger CDC-funded effort that aims to better understand communication challenges associated with weapons of mass destruction terrorism incidents. Presented here are formative research findings from 16 focus groups (n = 163) in which a multi-part, hypothetical radioactive materials terrorism situation was discussed. Twelve of the focus groups were carried out with members of the general public (drawn from a variety of ethnic backgrounds and geographic locations), and four groups were composed of first responders, hospital emergency department personnel, and public health professionals. One aim of the focus groups was to elicit detailed information on people's knowledge, views, perceptions, reactions, and concerns related to a nuclear/radiological terrorism event, and to better understand people's specific information needs and preferred information sources. A second aim was to pretest draft informational materials prepared by CDC and NIOSH. Key findings for the public and professional groups are presented, and the implications of the research for developing messages in radiological/nuclear terrorism situations are explored.

  4. Viewing boxes: a survey in diagnostic radiology departments of Moroccan hospitals.

    PubMed

    Bentayeb, F; Nfaoiu, K; Basraoui, O; Azevedo, A C P

    2010-10-01

    This work consists on a survey of the performance of viewing boxes installed in diagnostic radiology departments and included several aspects: checking the illuminance of the diagnostic rooms where the viewing boxes are located as well as the viewing boxes luminance levels and homogeneity. Seven hospitals took part in the survey, being three in the city of Casablanca and four in Rabat. A total of 136 viewing boxes and 18 diagnostic rooms have been checked. It was found that one diagnostic room works under normal conditions and that 80% of the viewing boxes present luminance levels below the international recommendations and the homogeneity is inadequate in 85%. Some simple and cheap initiatives can be performed in these departments to increase luminance and improve homogeneity levels such as cleaning and bulbs replacement. Copyright © 2009 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Prevalence of Paget's disease of bone in Italy.

    PubMed

    Gennari, Luigi; Di Stefano, Marco; Merlotti, Daniela; Giordano, Nicola; Martini, Giuseppe; Tamone, Cristina; Zatteri, Roberto; De Lucchi, Roberto; Baldi, Carlo; Vattimo, Angelo; Capoccia, Silvia; Burroni, Luca; Geraci, Simone; De Paola, Vincenzo; Calabrò, Anna; Avanzati, Annalisa; Isaia, Giancarlo; Nuti, Ranuccio

    2005-10-01

    We examined the prevalence of PDB in Italy from radiological, scintigraphic, and biochemical surveys in two Italian towns. Prevalence rates varied from 0.7% to 2.4%, were higher in males than in females, and slightly differed between the two towns. Unlike previous studies in populations of British descent, no secular trend for a decreasing prevalence emerged. Clinical, radiological, and necropsy data from different countries suggested pronounced geographical variations in the prevalence of Paget's disease of bone (PDB). Despite the impact of the disease on the population, there are limited data on the prevalence of PDB in Italy. The objective of this study was to estimate the prevalence of PDB in the district of Siena (Central Italy) and Turin (Northern Italy) from radiological, biochemical, and scintigraphic surveys. We examined a sample of 1778 consecutive pelvic radiographs performed between 1999 and 2000 at the Hospital Radiology Unit in Siena and 6609 pelvic radiographs performed in 1986-1987, 1992-1993, and 1999-2002 from the Radiology Department of Molinette Hospital in Turin. In Siena, 7906 consecutive (99m)TC-MDP bone scans performed over a 4-year period (January 2000 to May 2004) were also screened for the presence of PDB, and the prevalence of elevated alkaline phosphatase (ALP) levels (>300 UI/liter) was estimated from 7449 computerized medical records over a 3-year period (January 2000 to February 2003). The finding of PDB on the pelvic radiograph and bone scan was based on standardized radiological criteria. At the end of the radiological surveys, 16/1778 pelvic PDB cases (8 males and 8 females) were observed in Siena and 41/6609 (27 males and 14 females) in Turin. The crude prevalence of the disease was 0.89% in Siena and 0.62% in Turin. Given that pelvic involvement is commonly described in 60-90% of PDB patients, the estimated overall prevalence of PDB ranged from 1.0% to 1.5% in Siena and from 0.7% to 1.0% in Turin. No decrease in the prevalence of PDB was evident after comparison of prevalence rates from different periods. Biochemical analyses showed 296/7449 subjects with elevated ALP levels and normal liver enzymes, 87 of whom had confirmed diagnosis of PDB. The estimated prevalence of biochemical PDB was 1.5%. The scintigraphic survey showed a PDB prevalence of 194/7906 (2.4%), which was significantly higher than the radiological and biochemical estimates. Our surveys suggest that PDB in Italy has an estimated prevalence of at least 1%, comparable with that observed in United States and other European countries, but lower than that described in Britain and New Zealand. No secular trend for a decreasing prevalence of PDB was observed.

  6. Pre-surgical road map for thyroid cancer and large goiters: Practical benefits of detailed radiological evaluation by surgeon.

    PubMed

    Panchangam, Ramakanth Bhargav; Guntupalli, Satyam; Seetharamaiah, Thotakura; Kumbhar, Uday Shamrao

    2015-01-01

    Pre-surgical radiological evaluation of neck is often mandatory for surgical planning in high risk thyroid cancer and large goiters. Frequently, surgeons are overdependent on radiologist's report. In this context, we analysed the practical benefits of surgeon's independent radiological evaluation in our institutional experience. This prospective study was conducted in Endocrine Surgery department of a teaching hospital in South India. Cases operated between January 2011 and June 2012 (18 months) were included. Films of cross-sectional imaging were read in detail by primary and assistant surgeons in correlation with stepwise operative planning and documented. Cases with additional radiological signs on surgeon's evaluation, which were missing in radiologist's report are discussed in detail. F: M ratio is 67:24. Mean age was 45.3 ± 9.8 years (37 - 76). Forty-seven cases of thyroid cancer and 44 cases of large goiters were analysed. Surgeon read additional signs such as obliterated fat plane between goiter and subcutaneous plane; level I lymph nodes; bilateral cervical lymphadenopathy, internal jugular vein thrombus, and pharyngeal invasion helped in pre-operatively planned modification of operative steps for optimal R0 resection and total thyroidectomy. A mean of 1.42 ± 0.83 (1 - 6), additional signs were detected on surgeon's radiological evaluation compared to radiologist's report in 41.7% of cases. These findings modified the pre-operative plan, facilitating better surgical outcome in 28.6% of cases. In high-risk thyroid cancer and large goiters, detailed radiological evaluation by surgeon facilitates optimal surgical resection and superior outcome compared to radiologist report-guided surgery.

  7. The consequences of the economic crisis in radiology.

    PubMed

    2015-12-01

    The effects of the economic crisis have led to complex problems in radiology. The crisis has led to a reduction in the turnover of imaging equipment. This reflects on the quantity and quality of output, an aspect which is worsened by the contraction of the radiology market, late payments on supplies, and competitive procurement of medical goods centralized on a regional or national level. Many local and national institutions have operated with significant reductions of reimbursement for procedures, forcing a reorganization of facilities, manpower, and equipment. The reduction in operating margins of the industry has resulted in a reduction of invested capital for projects of industrial R&D and direct or indirect sponsorship. The quality of care will be affected with less comfortable conditions, reduction of local availability of radiologists, and failure to invest in lower dose equipment to control population medical radiation exposure. The crisis resulted in a reduction in the number of graduates in medicine and scholarships for specialization induced by linear cuts will result in a drastic reduction of radiological specialists. This will favour the development of teleradiology services, with the risk of accelerating the demedicalisation of radiology departments, and isolation of the professionals. • The economic crisis has led to reduction in the turnover of imaging equipment. • The economic crisis has led to reductions of reimbursement for procedures. • The economic crisis has led to reductions in operating margins of the industry. • The economic crisis has led to contraction of quantity and quality of output. • The economic crisis resulted in demedicalisation of radiology departments and isolation of professionals.

  8. Practical Implications for an Effective Radiology Residency Quality Improvement Program for Milestone Assessment.

    PubMed

    Leddy, Rebecca; Lewis, Madelene; Ackerman, Susan; Hill, Jeanne; Thacker, Paul; Matheus, Maria; Tipnis, Sameer; Gordon, Leonie

    2017-01-01

    Utilization of a radiology resident-specific quality improvement (QI) program and curriculum based on the Accreditation Council for Graduate Medical Education (ACGME) milestones can enable a program's assessment of the systems-based practice component and prepare residents for QI implementation post graduation. This article outlines the development process, curriculum, QI committee formation, and resident QI project requirements of one institution's designated radiology resident QI program. A method of mapping the curriculum to the ACGME milestones and assessment of resident competence by postgraduate year level is provided. Sample projects, challenges to success, and lessons learned are also described. Survey data of current trainees and alumni about the program reveal that the majority of residents and alumni responders valued the QI curriculum and felt comfortable with principles and understanding of QI. The most highly valued aspect of the program was the utilization of a resident education committee. The majority of alumni responders felt the residency quality curriculum improved understanding of QI, assisted with preparation for the American Board of Radiology examination, and prepared them for QI in their careers. In addition to the survey results, outcomes of resident project completion and resident scholarly activity in QI are evidence of the success of this program. It is hoped that this description of our experiences with a radiology resident QI program, in accordance with the ACGME milestones, may facilitate the development of successful QI programs in other diagnostic radiology residencies. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  9. Molecular aspects of magnetic resonance imaging and spectroscopy.

    PubMed

    Boesch, C

    1999-01-01

    Magnetic resonance imaging (MRI) is a well known diagnostic tool in radiology that produces unsurpassed images of the human body, in particular of soft tissue. However, the medical community is often not aware that MRI is an important yet limited segment of magnetic resonance (MR) or nuclear magnetic resonance (NMR) as this method is called in basic science. The tremendous morphological information of MR images sometimes conceal the fact that MR signals in general contain much more information, especially on processes on the molecular level. NMR is successfully used in physics, chemistry, and biology to explore and characterize chemical reactions, molecular conformations, biochemical pathways, solid state material, and many other applications that elucidate invisible characteristics of matter and tissue. In medical applications, knowledge of the molecular background of MRI and in particular MR spectroscopy (MRS) is an inevitable basis to understand molecular phenomenon leading to macroscopic effects visible in diagnostic images or spectra. This review shall provide the necessary background to comprehend molecular aspects of magnetic resonance applications in medicine. An introduction into the physical basics aims at an understanding of some of the molecular mechanisms without extended mathematical treatment. The MR typical terminology is explained such that reading of original MR publications could be facilitated for non-MR experts. Applications in MRI and MRS are intended to illustrate the consequences of molecular effects on images and spectra.

  10. Physical and cognitive task analysis in interventional radiology.

    PubMed

    Johnson, S; Healey, A; Evans, J; Murphy, M; Crawshaw, M; Gould, D

    2006-01-01

    To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model.

  11. Handheld technology acceptance in radiologic science education and training programs

    NASA Astrophysics Data System (ADS)

    Powers, Kevin Jay

    The purpose of this study was to explore the behavioral intention of directors of educational programs in the radiologic sciences to adopt handheld devices to aid in managing student clinical data. Handheld devices were described to participants as a technology representing a class of mobile electronic devices including, but not limited to, personal digital assistants such as a Palm TX, Apple iPod Touch, Apple iPad or Hewlett Packard iPaq, and cellular or smartphones with third generation mobile capabilities such as an Apple iPhone, Blackberry or Android device. The study employed a non-experimental, cross-sectional survey design to determine the potential of adopting handheld technologies based on the constructs of Davis's (1989) Technology Acceptance Model. An online self-report questionnaire survey instrument was used to gather study data from 551 entry level radiologic science programs specializing in radiography, radiation therapy, nuclear medicine and medical sonography. The study design resulted in a single point in time assessment of the relationship between the primary constructs of the Technology Acceptance Model: perceived usefulness and perceived ease of use, and the behavioral intention of radiography program directors to adopt the information technology represented by hand held devices. Study results provide justification for investing resources to promote the adoption of mobile handheld devices in radiologic science programs and study findings serve as a foundation for further research involving technology adoption in the radiologic sciences.

  12. Changes in the market for diagnostic radiologists as measured through a help wanted index.

    PubMed

    Forman, H P; Kamin, D S; Covey, A M; Sunshine, J H

    2000-04-01

    We sought to create and validate a help wanted index for tracking changes in the radiology job market. All jobs advertised in Radiology and the American Journal of Roentgenology from January 1991 through December 1998 were tracked according to three separate parameters: academic versus private practice, subspecialty, and region. Statistical comparison was made between the first and second 48-month subperiods to identify changes. Thirteen thousand seven hundred one advertised positions were coded. A dramatic decrease in job advertisements was noted after December 1991, with advertisements falling to one eighth of their late 1991 peak. A recovery has occurred, with advertising now approaching peak levels. Shifts were seen toward more private practice, midwestern location, vascular and interventional, and mammography positions. Declines occurred in the share of positions in California, the Southwest, and several radiology subspecialties. Other trends were noted but were statistically less significant. A strong correlation (R = 0.98) was found between the annual number of positions advertised and radiologists' median incomes relative to those of all physicians. The job market in radiology, much as in other fields, can be tracked in a coincident manner with the use of a help wanted index. Changes in the makeup of radiology practice are important and are identified in a well-constructed index. These findings have validity and can be useful as an adjunct to other information for policy and planning purposes.

  13. Selected radionuclides important to low-level radioactive waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-11-01

    The purpose of this document is to provide information to state representatives and developers of low level radioactive waste (LLW) management facilities about the radiological, chemical, and physical characteristics of selected radionuclides and their behavior in the environment. Extensive surveys of available literature provided information for this report. Certain radionuclides may contribute significantly to the dose estimated during a radiological performance assessment analysis of an LLW disposal facility. Among these are the radionuclides listed in Title 10 of the Code of Federal Regulations Part 61.55, Tables 1 and 2 (including alpha emitting transuranics with half-lives greater than 5 years). Thismore » report discusses these radionuclides and other radionuclides that may be significant during a radiological performance assessment analysis of an LLW disposal facility. This report not only includes essential information on each radionuclide, but also incorporates waste and disposal information on the radionuclide, and behavior of the radionuclide in the environment and in the human body. Radionuclides addressed in this document include technetium-99, carbon-14, iodine-129, tritium, cesium-137, strontium-90, nickel-59, plutonium-241, nickel-63, niobium-94, cobalt-60, curium -42, americium-241, uranium-238, and neptunium-237.« less

  14. Nevada National Security Site Radiological Control Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radiological Control Managers’ Council

    2012-03-26

    This document supersedes DOE/NV/25946--801, 'Nevada Test Site Radiological Control Manual,' Revision 1 issued in February 2010. Brief Description of Revision: A complete revision to reflect a recent change in name for the NTS; changes in name for some tenant organizations; and to update references to current DOE policies, orders, and guidance documents. Article 237.2 was deleted. Appendix 3B was updated. Article 411.2 was modified. Article 422 was re-written to reflect the wording of DOE O 458.1. Article 431.6.d was modified. The glossary was updated. This manual contains the radiological control requirements to be used for all radiological activities conducted bymore » programs under the purview of the U.S. Department of Energy (DOE) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection.' Programs covered by this manual are located at the Nevada National Security Site (NNSS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Livermore, California; and Andrews Air Force Base, Maryland. In addition, fieldwork by NNSA/NSO at other locations is covered by this manual. Current activities at NNSS include operating low-level radioactive and mixed waste disposal facilities for United States defense-generated waste, assembly and execution of subcritical experiments, assembly/disassembly of special experiments, the storage and use of special nuclear materials, performing criticality experiments, emergency responder training, surface cleanup and site characterization of contaminated land areas, environmental activity by the University system, and nonnuclear test operations, such as controlled spills of hazardous materials at the Hazardous Materials Spill Center. Currently, the major potential for occupational radiation exposure is associated with the burial of low-level radioactive waste and the handling of radioactive sources. Remediation of contaminated land areas may also result in radiological exposures.« less

  15. Costing in Radiology and Health Care: Rationale, Relativity, Rudiments, and Realities.

    PubMed

    Rubin, Geoffrey D

    2017-02-01

    Costs direct decisions that influence the effectiveness of radiology in the care of patients on a daily basis. Yet many radiologists struggle to harness the power of cost measurement and cost management as a critical path toward establishing their value in patient care. When radiologists cannot articulate their value, they risk losing control over how imaging is delivered and supported. In the United States, recent payment trends directing value-based payments for bundles of care advance the imperative for radiology providers to articulate their value. This begins with the development of an understanding of the providers' own costs, as well as the complex interrelationships and imaging-associated costs of other participants across the imaging value chain. Controlling the costs of imaging necessitates understanding them at a procedural level and quantifying the costs of delivering specific imaging services. Effective product-level costing is dependent on a bottom-up approach, which is supported through recent innovations in time-dependent activity-based costing. Once the costs are understood, they can be managed. Within the high fixed cost and high overhead cost environment of health care provider organizations, stakeholders must understand the implications of misaligned top-down cost management approaches that can both paradoxically shift effort from low-cost workers to much costlier professionals and allocate overhead costs counterproductively. Radiology's engagement across a broad spectrum of care provides an excellent opportunity for radiology providers to take a leading role within the health care organizations to enhance value and margin through principled and effective cost management. Following a discussion of the rationale for measuring costs, this review contextualizes costs from the perspectives of a variety of stakeholders (relativity), discusses core concepts in how costs are classified (rudiments), presents common and improved methods for measuring costs in health care, and discusses how cost management strategies can either improve or hinder high-value health care (realities). © RSNA, 2017 Online supplemental material is available for this article.

  16. Improved Identification of Noun Phrases in Clinical Radiology Reports Using a High-Performance Statistical Natural Language Parser Augmented with the UMLS Specialist Lexicon

    PubMed Central

    Huang, Yang; Lowe, Henry J.; Klein, Dan; Cucina, Russell J.

    2005-01-01

    Objective: The aim of this study was to develop and evaluate a method of extracting noun phrases with full phrase structures from a set of clinical radiology reports using natural language processing (NLP) and to investigate the effects of using the UMLS® Specialist Lexicon to improve noun phrase identification within clinical radiology documents. Design: The noun phrase identification (NPI) module is composed of a sentence boundary detector, a statistical natural language parser trained on a nonmedical domain, and a noun phrase (NP) tagger. The NPI module processed a set of 100 XML-represented clinical radiology reports in Health Level 7 (HL7)® Clinical Document Architecture (CDA)–compatible format. Computed output was compared with manual markups made by four physicians and one author for maximal (longest) NP and those made by one author for base (simple) NP, respectively. An extended lexicon of biomedical terms was created from the UMLS Specialist Lexicon and used to improve NPI performance. Results: The test set was 50 randomly selected reports. The sentence boundary detector achieved 99.0% precision and 98.6% recall. The overall maximal NPI precision and recall were 78.9% and 81.5% before using the UMLS Specialist Lexicon and 82.1% and 84.6% after. The overall base NPI precision and recall were 88.2% and 86.8% before using the UMLS Specialist Lexicon and 93.1% and 92.6% after, reducing false-positives by 31.1% and false-negatives by 34.3%. Conclusion: The sentence boundary detector performs excellently. After the adaptation using the UMLS Specialist Lexicon, the statistical parser's NPI performance on radiology reports increased to levels comparable to the parser's native performance in its newswire training domain and to that reported by other researchers in the general nonmedical domain. PMID:15684131

  17. Intermediate clinical and radiological results of cervical TDR (Mobi-C®) with up to 2 years of follow-up

    PubMed Central

    Beaurain, J.; Bernard, P.; Dufour, T.; Fuentes, J. M.; Hovorka, I.; Huppert, J.; Steib, J. P.; Vital, J. M.; Aubourg, L.

    2009-01-01

    The interest in cervical total disc replacement (TDR) as an alternative to the so-far gold standard in the surgical treatment of degenerative disc disease (DDD), e.g anterior cervical discectomy and fusion (ACDF), is growing very rapidly. Many authors have established the fact that ACDF may result in progressive degeneration in adjacent segments. On the contrary, but still theoretically, preservation of motion with TDR at the surgically treated level may potentially reduce the occurrence of adjacent-level degeneration (ALD). The authors report the intermediate results of an undergoing multicentre prospective study of TDR with Mobi-C® prosthesis. The aim of the study was to assess the safety and efficacy of the device in the treatment of DDD and secondary to evaluate the radiological status of adjacent levels and the occurrence of ossifications, at 2-year follow-up (FU). 76 patients have performed their 2-year FU visit and have been analyzed clinically and radiologically. Clinical outcomes (NDI, VAS, SF-36) and ROM measurements were analyzed pre-operatively and at the different post-operative time-points. Complications and re-operations were also assessed. Occurrences of heterotopic ossifications (HOs) and of adjacent disc degeneration radiographic changes have been analyzed from 2-year FU X-rays. The mean NDI and VAS scores for arm and neck are reduced significantly at each post-operative time-point compared to pre-operative condition. Motion is preserved over the time at index levels (mean ROM = 9° at 2 years) and 85.5% of the segments are mobile at 2 years. HOs are responsible for the fusion of 6/76 levels at 2 years. However, presence of HO does not alter the clinical outcomes. The occurrence rate of radiological signs of ALD is very low at 2 years (9.1%). There has been no subsidence, no expulsion and no sub-luxation of the implant. Finally, after 2 years, 91% of the patients assume that they would undergo the procedure again. These intermediate results of TDR with Mobi-C® are very encouraging and seem to confirm the efficacy and the safety of the device. Regarding the preservation of the status of the adjacent levels, the results of this unconstrained device are encouraging, but longer FU studies are needed to prove it. PMID:19434431

  18. Effect of Osteoprotegerin and Dickkopf-Related Protein 1 on Radiological Progression in Tightly Controlled Rheumatoid Arthritis

    PubMed Central

    Martín, Irene; Loza, Estibaliz; Carmona, Loreto; Ivorra, José; Narváez, José Antonio; Hernández-Gañán, Javier; Alía, Pedro

    2016-01-01

    Objective To analyze the association between circulating osteoprotegerin (OPG) and Dickkopf-related protein 1 (DKK-1) and radiological progression in patients with tightly controlled rheumatoid arthritis (RA). Methods Serum levels of OPG and DKK-1 were measured in 97 RA patients who were treated according to a treat-to-target strategy (T2T) aimed at remission (DAS28<2.6). Radiologic joint damage progression was assessed by changes in the total Sharp-van der Heijde score (SHS) on serial radiographs of the hands and feet. The independent association between these biomarker levels and the structural damage endpoint was examined using regression analysis Results The mean age of the 97 RA patients (68 women) at the time of the study was 54 ± 14 years, and the median disease duration was 1.6 ± 1.5 years. Most patients were seropositive for either RF or ACPA, and the large majority (76%) were in remission or had low disease activity. After a median follow-up time of 3.3 ± 1.5 years (range, 1–7.5 yrs.), the mean total SHS annual progression was 0.88 ± 2.20 units. Fifty-two percent of the patients had no progression (defined as a total SHS of zero). The mean serum OPG level did not change significantly over the study period (from 3.9 ± 1.8 to 4.07 ± 2.23 pmol/L), whereas the mean serum DKK-1 level decreased, although not significantly (from 29.9 ± 10.9 to 23.6 ± 18.8 pmol/L). In the multivariate analysis, the predictive factors increasing the likelihood of total SHS progression were age (OR per year = 1.10; p = 0.003) and a high mean C-reactive protein level over the study period (OR = 1.29; p = 0.005). Circulating OPG showed a protective effect reducing the likelihood of joint space narrowing by 60% (95% CI: 0.38–0.94) and the total SHS progression by 48% (95% CI: 0.28–0.83). The DKK-1 levels were not associated with radiological progression. Conclusion In patients with tightly controlled RA, serum OPG was inversely associated with progression of joint destruction. This biomarker may be useful in combination with other risk factors to improve prediction in patients in clinical remission or low disease activity state. PMID:27911913

  19. Radiological protection issues arising during and after the Fukushima nuclear reactor accident.

    PubMed

    González, Abel J; Akashi, Makoto; Boice, John D; Chino, Masamichi; Homma, Toshimitsu; Ishigure, Nobuhito; Kai, Michiaki; Kusumi, Shizuyo; Lee, Jai-Ki; Menzel, Hans-Georg; Niwa, Ohtsura; Sakai, Kazuo; Weiss, Wolfgang; Yamashita, Shunichi; Yonekura, Yoshiharu

    2013-09-01

    Following the Fukushima accident, the International Commission on Radiological Protection (ICRP) convened a task group to compile lessons learned from the nuclear reactor accident at the Fukushima Daiichi nuclear power plant in Japan, with respect to the ICRP system of radiological protection. In this memorandum the members of the task group express their personal views on issues arising during and after the accident, without explicit endorsement of or approval by the ICRP. While the affected people were largely protected against radiation exposure and no one incurred a lethal dose of radiation (or a dose sufficiently large to cause radiation sickness), many radiological protection questions were raised. The following issues were identified: inferring radiation risks (and the misunderstanding of nominal risk coefficients); attributing radiation effects from low dose exposures; quantifying radiation exposure; assessing the importance of internal exposures; managing emergency crises; protecting rescuers and volunteers; responding with medical aid; justifying necessary but disruptive protective actions; transiting from an emergency to an existing situation; rehabilitating evacuated areas; restricting individual doses of members of the public; caring for infants and children; categorising public exposures due to an accident; considering pregnant women and their foetuses and embryos; monitoring public protection; dealing with 'contamination' of territories, rubble and residues and consumer products; recognising the importance of psychological consequences; and fostering the sharing of information. Relevant ICRP Recommendations were scrutinised, lessons were collected and suggestions were compiled. It was concluded that the radiological protection community has an ethical duty to learn from the lessons of Fukushima and resolve any identified challenges. Before another large accident occurs, it should be ensured that inter alia: radiation risk coefficients of potential health effects are properly interpreted; the limitations of epidemiological studies for attributing radiation effects following low exposures are understood; any confusion on protection quantities and units is resolved; the potential hazard from the intake of radionuclides into the body is elucidated; rescuers and volunteers are protected with an ad hoc system; clear recommendations on crisis management and medical care and on recovery and rehabilitation are available; recommendations on public protection levels (including infant, children and pregnant women and their expected offspring) and associated issues are consistent and understandable; updated recommendations on public monitoring policy are available; acceptable (or tolerable) 'contamination' levels are clearly stated and defined; strategies for mitigating the serious psychological consequences arising from radiological accidents are sought; and, last but not least, failures in fostering information sharing on radiological protection policy after an accident need to be addressed with recommendations to minimise such lapses in communication.

  20. Radiologic Monitoring of Faculty and Staff in an Electrophysiology Lab Using a Real-Time Dose Monitoring System

    ERIC Educational Resources Information Center

    Chardenet, Kathleen A.

    2016-01-01

    Purpose: A real-time dose management system was used to determine if radiation exposure levels would decrease when providers were privy to their real-time radiation exposure levels. Six aggregate categories of providers were first blinded (phase 1) and subsequently made aware of their radiation exposure levels during electrophysiology procedures…

  1. Clinical Predictors and Outcome of Metabolic Acidosis in Under-Five Children Admitted to an Urban Hospital in Bangladesh with Diarrhea and Pneumonia

    PubMed Central

    Chisti, Mohammod J.; Ahmed, Tahmeed; Ashraf, Hasan; Faruque, A. S. G.; Bardhan, Pradip K.; Dey, Sanjoy Kumer; Huq, Sayeeda; Das, Sumon Kumar; Salam, Mohammed A.

    2012-01-01

    Background Clinical features of metabolic acidosis and pneumonia frequently overlap in young diarrheal children, resulting in differentiation from each other very difficult. However, there is no published data on the predictors of metabolic acidosis in diarrheal children also having pneumonia. Our objective was to evaluate clinical predictors of metabolic acidosis in under-five diarrheal children with radiological pneumonia, and their outcome. Methods We prospectively enrolled all under-five children (n = 164) admitted to the Special Care Ward (SCW) of the Dhaka Hospital of icddr, b between September and December 2007 with diarrhea and radiological pneumonia who also had their total serum carbon-dioxide estimated. We compared the clinical features and outcome of children with radiological pneumonia and diarrhea with (n = 98) and without metabolic acidosis (n = 66). Results Children with metabolic acidosis more often had higher case-fatality (16% vs. 5%, p = 0.039) compared to those without metabolic acidosis on admission. In logistic regression analysis, after adjusting for potential confounders such as age of the patient, fever on admission, and severe wasting, the independent predictors of metabolic acidosis in under-five diarrheal children having pneumonia were clinical dehydration (OR 3.57, 95% CI 1.62–7.89, p = 0.002), and low systolic blood pressure even after full rehydration (OR 1.02, 95% CI 1.01–1.04, p = 0.005). Proportions of children with cough, respiratory rate/minute, lower chest wall indrawing, nasal flaring, head nodding, grunting respiration, and cyanosis were comparable (p>0.05) among the groups. Conclusion and Significance Under-five diarrheal children with radiological pneumonia having metabolic acidosis had frequent fatal outcome than those without acidosis. Clinical dehydration and persistent systolic hypotension even after adequate rehydration were independent clinical predictors of metabolic acidosis among the children. However, metabolic acidosis in young diarrheal children had no impact on the diagnostic clinical features of radiological pneumonia which underscores the importance of early initiation of appropriate antibiotics to combat morbidity and deaths in such population. PMID:22720060

  2. Compression for radiological images

    NASA Astrophysics Data System (ADS)

    Wilson, Dennis L.

    1992-07-01

    The viewing of radiological images has peculiarities that must be taken into account in the design of a compression technique. The images may be manipulated on a workstation to change the contrast, to change the center of the brightness levels that are viewed, and even to invert the images. Because of the possible consequences of losing information in a medical application, bit preserving compression is used for the images used for diagnosis. However, for archiving the images may be compressed to 10 of their original size. A compression technique based on the Discrete Cosine Transform (DCT) takes the viewing factors into account by compressing the changes in the local brightness levels. The compression technique is a variation of the CCITT JPEG compression that suppresses the blocking of the DCT except in areas of very high contrast.

  3. Final Status Survey Report for Corrective Action Unit 117 - Pluto Disassembly Facility, Building 2201, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeremy Gwin and Douglas Frenette

    This document contains the process knowledge, radiological data and subsequent statistical methodology and analysis to support approval for the radiological release of Corrective Action Unit (CAU) 117 – Pluto Disassembly Facility, Building 2201 located in Area 26 of the Nevada National Security Site (NNSS). Preparations for release of the building began in 2009 and followed the methodology described in the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). MARSSIM is the DOE approved process for release of Real Property (buildings and landmasses) to a set of established criteria or authorized limits. The pre-approved authorized limits for surface contamination values andmore » corresponding assumptions were established by DOE O 5400.5. The release criteria coincide with the acceptance criteria of the U10C landfill permit. The U10C landfill is the proposed location to dispose of the radiologically non-impacted, or “clean,” building rubble following demolition. However, other disposition options that include the building and/or waste remaining at the NNSS may be considered providing that the same release limits apply. The Final Status Survey was designed following MARSSIM guidance by reviewing historical documentation and radiological survey data. Following this review a formal radiological characterization survey was performed in two phases. The characterization revealed multiple areas of residual radioactivity above the release criteria. These locations were remediated (decontaminated) and then the surface activity was verified to be less than the release criteria. Once remediation efforts had been successfully completed, a Final Status Survey Plan (10-015, “Final Status Survey Plan for Corrective Action Unit 117 – Pluto Disassembly Facility, Building 2201”) was developed and implemented to complete the final step in the MARSSIM process, the Final Status Survey. The Final Status Survey Plan consisted of categorizing each individual room into one of three categories: Class 1, Class 2 or Class 3 (a fourth category is a “Non-Impacted Class” which in the case of Building 2201 only pertained to exterior surfaces of the building.) The majority of the rooms were determined to fall in the less restrictive Class 3 category, however, Rooms 102, 104, 106, and 107 were identified as containing Class 1 and 2 areas. Building 2201 was divided into “survey units” and surveyed following the requirements of the Final Status Survey Plan for each particular class. As each survey unit was completed and documented, the survey results were evaluated. Each sample (static measurement) with units of counts per minute (cpm) was corrected for the appropriate background and converted to a value with units of dpm/100 cm2. With a surface contamination value in the appropriate units, it was compared to the surface contamination limits, or in this case the derived concentration guideline level (DCGLw). The appropriate statistical test (sign test) was then performed. If the survey unit was statistically determined to be below the DCGLw, then the survey unit passed and the null hypothesis (that the survey unit is above limits) was rejected. If the survey unit was equal to or below the critical value in the sign test, the null hypothesis was not rejected. This process was performed for all survey units within Building 2201. A total of thirty-three “Class 1,” four “Class 2,” and one “Class 3” survey units were developed, surveyed, and evaluated. All survey units successfully passed the statistical test. Building 2201 meets the release criteria commensurate with the Waste Acceptance Criteria (for radiological purposes) of the U10C landfill permit residing within NNSS boundaries. Based on the thorough statistical sampling and scanning of the building’s interior, Building 2201 may be considered radiologically “clean,” or free of contamination.« less

  4. Variability in the Use of Simulation for Procedural Training in Radiology Residency: Opportunities for Improvement.

    PubMed

    Matalon, Shanna A; Chikarmane, Sona A; Yeh, Eren D; Smith, Stacy E; Mayo-Smith, William W; Giess, Catherine S

    2018-03-19

    Increased attention to quality and safety has led to a re-evaluation of the classic apprenticeship model for procedural training. Many have proposed simulation as a supplementary teaching tool. The purpose of this study was to assess radiology resident exposure to procedural training and procedural simulation. An IRB-exempt online survey was distributed to current radiology residents in the United States by e-mail. Survey results were summarized using frequency and percentages. Chi-square tests were used for statistical analysis where appropriate. A total of 353 current residents completed the survey. 37% (n = 129/353) of respondents had never used procedure simulation. Of the residents who had used simulation, most did not do so until after having already performed procedures on patients (59%, n = 132/223). The presence of a dedicated simulation center was reported by over half of residents (56%, n = 196/353) and was associated with prior simulation experience (P = 0.007). Residents who had not had procedural simulation were somewhat likely or highly likely (3 and 4 on a 4-point Likert-scale) to participate if it were available (81%, n = 104/129). Simulation training was associated with higher comfort levels in performing procedures (P < 0.001). Although procedural simulation training is associated with higher comfort levels when performing procedures, there is variable use in radiology resident training and its use is not currently optimized. Given the increased emphasis on patient safety, these results suggest the need to increase procedural simulation use during residency, including an earlier introduction to simulation before patient exposure. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Adjacent Segment Disease After Cervical Spine Fusion: Evaluation of a 70 Patient Long-Term Follow-Up.

    PubMed

    Alhashash, Mohamed; Shousha, Mootaz; Boehm, Heinrich

    2018-05-01

    A retrospective study of 70 patients undergoing surgical treatment for adjacent segment disease (ASD) after anterior cervical decompression and fusion (ACDF). To analyze the risk factors for the development of ASD in patients who underwent ACDF. ACDF has provided a high rate of clinical success for the cervical degenerative disc disease; nevertheless, adjacent segment degeneration has been reported as a complication at the adjacent level secondary to the rigid fixation. Between January 2005 and December 2012, 70 consecutive patients underwent surgery for ASD after ACDF in our institution. In all patients thorough clinical and radiological examination was performed preoperatively, postoperatively, and at the final follow-up. The clinical data included the Neck Disability Index (NDI) and the Visual Analogue Scale (VAS). The radiological evaluation included x-rays and magnetic resonance imaging (MRI) for all patients. The duration of follow up after the adjacent segment operation ranged from 3 to 10 years. Surgery for ASD was performed after a mean period of 32 months from the primary ACDF. ASD occurred after single level ACDF in 54% of cases, most commonly after C5/6 fusion (28%). Risk factors for ASD were found to be preexisting radiological signs of degeneration at the primary surgery (74%) and bad sagittal profile after the primary ACDF (90%). ASD occurred predominantly in the middle cervical region (C4-6); especially in patients with preexisting evidence of radiological degeneration in the adjacent segment at the time of primary cervical fusion, notably when this surgery failed to restore or maintain the cervical lordosis. 4.

  6. 76 FR 64960 - Federal Radiological Preparedness Coordinating Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-19

    ... Atomic Energy Agency Notification Following a Domestic Nuclear Power Plant Incident, and (5) Senior Official Exercise/ Principal Level Exercise SOE/PLE 3-10 Nuclear Power Plant Communications Update. The...

  7. Elevation of water table and various stratigraphic surfaces beneath e area low level waste disposal facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bagwell, Laura; Bennett, Patti

    2017-11-02

    This memorandum describes work that supports revision of the Radiological Performance Assessment (PA) for the E Area Low Level Radioactive Waste Disposal Facility (LLRWDF). The work summarized here addresses portions of the PA Strategic Planning Team's recommendation #148b (Butcher and Phifer, 2016).

  8. Clinical and Radiological Outcomes Comparing Percutaneous Chevron-Akin Osteotomies vs Open Scarf-Akin Osteotomies for Hallux Valgus.

    PubMed

    Lai, Mun Chun; Rikhraj, Inderjeet Singh; Woo, Yew Lok; Yeo, William; Ng, Yung Chuan Sean; Koo, Kevin

    2018-03-01

    Minimally invasive surgeries have gained popularity due to less soft tissue trauma and better wound healing. To date, limited studies have compared the outcomes of percutaneous and open osteotomies. This study aims to investigate the clinical and radiological outcomes of percutaneous chevron-Akin osteotomies vs open scarf-Akin osteotomies at 24-month follow-up. We reviewed a prospectively collected database in a tertiary hospital hallux valgus registry. Twenty-nine feet that underwent a percutaneous technique were matched to 58 feet that underwent open scarf and Akin osteotomies. Clinical outcome measures assessed included visual analog scale (VAS) scores, American Orthopaedic Foot & Ankle Society Hallux Metatarsophalangeal-Interphalangeal score (AOFAS Hallux MTP-IP), and Short Form 36 (SF-36) Health Survey. Radiological outcomes included hallux valgus angle (HVA) and intermetatarsal angle (IMA). All patients were prospectively followed up at 6 and 24 months. Both groups showed comparable clinical and radiological outcomes at the 24-month follow-up. However, the percutaneous group demonstrated less pain in the perioperative period ( P < .001). There were significant differences in the change in HVA between the groups but comparable radiological outcomes in IMA at the 24-month follow-up. The percutaneous group demonstrated shorter length of operation ( P < .001). There were no complications in the percutaneous group but 3 wound complications in the open group. We conclude that clinical and radiological outcomes of third-generation percutaneous chevron-Akin osteotomies were comparable with open scarf and Akin osteotomies at 24 months but with significantly less perioperative pain, shorter length of operation, and less risk of wound complications. Level III, retrospective comparative series.

  9. Trainees May Add Value to Patient Care by Decreasing Addendum Utilization in Radiology Reports.

    PubMed

    Balthazar, Patricia; Konstantopoulos, Christina; Wick, Carson A; DeSimone, Ariadne K; Tridandapani, Srini; Simoneaux, Stephen; Applegate, Kimberly E

    2017-11-01

    The purpose of this study was to evaluate the impact of trainee involvement and other factors on addendum rates in radiology reports. This retrospective study was performed in a tertiary care pediatric hospital. From the institutional radiology data repository, we extracted all radiology reports from January 1 to June 30, 2016, as well as trainee (resident or fellow) involvement, imaging modality, patient setting (emergency, inpatient, or outpatient), order status (routine vs immediate), time of interpretation (regular work hours vs off-hours), radiologist's years of experience, and sex. We grouped imaging modalities as advanced (CT, MRI, and PET) or nonadvanced (any modality that was not CT, MRI, or PET) and radiologist experience level as ≤ 20 years or > 20 years. Our outcome measure was the rate of addenda in radiology reports. Statistical analysis was performed using multivariate logistic regression. From 129,033 reports finalized during the study period, 418 (0.3%) had addenda. Reports generated without trainees were 12 times more likely than reports with trainee involvement to have addenda (odds ratio [OR] = 12.2, p < 0.001). Advanced imaging studies were more likely than nonadvanced studies to be associated with addendum use (OR = 4.7, p < 0.001). Reports generated for patients in emergency or outpatient settings had a slightly higher likelihood of addendum use than those in an inpatient setting (OR = 1.5, p = 0.04; and OR = 1.3, p = 0.04, respectively). Routine orders had a slightly higher likelihood of addendum use compared with immediate orders (OR = 1.3, p = 0.01). We found no difference in addendum use by radiologist's sex, radiologist's years of experience, emergency versus outpatient setting, or time of interpretation. Trainees may add value to patient care by decreasing addendum rates in radiology reports.

  10. Radiology medical student education: an outcome-based survey of PGY-1 residents.

    PubMed

    Saha, Arnold; Roland, R Andrew; Hartman, Matthew S; Daffner, Richard H

    2013-03-01

    Postgraduate year (PGY)-1 residents are frequently required to order imaging studies and make preliminary interpretations on them. This study determines whether PGY-1 residents feel their radiology education in medical school sufficiently trained them for the clinical responsibilities of internship. This multicenter, institutional review board-approved survey asked PGY-1 trainees three categories of questions: 1) extent of medical school training for ordering and interpreting imaging studies, 2) confidence levels in ordering appropriate imaging studies and making common/emergent diagnoses, and 3) rating the importance of radiologic interpretation by interns. Respondents also submitted ideas for medical school teaching topics deemed most useful for interns. A total of 175 questionnaires were returned with good representation across specialties. Although 63.7% of interns were frequently asked to independently preview radiology studies, 12.6% received no formal radiology training in medical school. Participants rated chest radiographs as the most important study for interns to competently interpret (93.4% reporting very or extremely important). However, only 60.2% of interns reported high confidence in recognizing common/emergent pulmonary findings, and 56.3% for evaluating line and tube position. With regard to ordering imaging studies, 81.0% had never used or never heard of the American College of Radiology Appropriateness Criteria®. Only 33.1% had high confidence in knowing when to order oral/intravenous contrast. Similar low percentages had high confidence identifying and premedicating contrast allergies (36.4%) and knowing risk factors of nephrogenic systemic fibrosis (13.2%). PGY-1 residents feel that medical school curriculum emphasizing interpretation of chest radiographs and ordering appropriate imaging studies would better prepare students for the responsibilities of internship. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  11. SU-E-E-01: ABR Diagnostic Radiology Core Exam: Was Our Redesigned Physics Course Successful in Teaching Physics to Radiology Residents?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanal, K; Hoff, M; Dickinson, R

    Purpose: Our purpose is to evaluate the effectiveness of our two year physics course in preparing radiology residents for the American Board of Radiology (ABR) diagnostic radiology exam. Methods: We designed a new two-year physics course that integrates radiology clinical content and practice and is primarily based on the AAPM curriculum and RSNA/AAPM physics modules. Biweekly classes focus on relevant concepts from assigned reading and use audience response systems to encourage participation. Teaching efficiency is optimized through lecturer rotations of physicists, radiologists, and guest speakers. An emphasis is placed on clinical relevance by requiring lab work and providing equipment demonstrations.more » Periodic quiz were given during the course. The course website was also redesigned for usability, and physics review lectures were conducted two weeks before the board exam to refresh key concepts. At the completion of our first two-year course, we conducted a confidential evaluation of the faculty and course. The evaluation assessed metrics such as overall organization, clinical relevance of content, and level of difficulty, with a rating scale from poor to excellent. Results: Our evaluation indicated that the redesigned course provided effective board exam preparation, with most responses between good and excellent. There was some criticism on the course length and on chronological discontinuity, but the review lectures were appreciated by the residents. All of our residents passed the physics component of the ABR exam with scores exceeding the minimum passing score by a significant margin. Conclusion: The course evaluation and board exam results indicate that our new two-year course format provides valuable board exam preparation. This is possible thanks to the time and effort taken by the physics faculty on ensuring the residents get quality physics education.« less

  12. The Role of Artificial Intelligence in Diagnostic Radiology: A Survey at a Single Radiology Residency Training Program.

    PubMed

    Collado-Mesa, Fernando; Alvarez, Edilberto; Arheart, Kris

    2018-02-21

    Advances in artificial intelligence applied to diagnostic radiology are predicted to have a major impact on this medical specialty. With the goal of establishing a baseline upon which to build educational activities on this topic, a survey was conducted among trainees and attending radiologists at a single residency program. An anonymous questionnaire was distributed. Comparisons of categorical data between groups (trainees and attending radiologists) were made using Pearson χ 2 analysis or an exact analysis when required. Comparisons were made using the Wilcoxon rank sum test when the data were not normally distributed. An α level of 0.05 was used. The overall response rate was 66% (69 of 104). Thirty-six percent of participants (n = 25) reported not having read a scientific medical article on the topic of artificial intelligence during the past 12 months. Twenty-nine percent of respondents (n = 12) reported using artificial intelligence tools during their daily work. Trainees were more likely to express doubts on whether they would have pursued diagnostic radiology as a career had they known of the potential impact artificial intelligence is predicted to have on the specialty (P = .0254) and were also more likely to plan to learn about the topic (P = .0401). Radiologists lack exposure to current scientific medical articles on artificial intelligence. Trainees are concerned by the implications artificial intelligence may have on their jobs and desire to learn about the topic. There is a need to develop educational resources to help radiologists assume an active role in guiding and facilitating the development and implementation of artificial intelligence tools in diagnostic radiology. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. UWGSP6: a diagnostic radiology workstation of the future

    NASA Astrophysics Data System (ADS)

    Milton, Stuart W.; Han, Sang; Choi, Hyung-Sik; Kim, Yongmin

    1993-06-01

    The Univ. of Washington's Image Computing Systems Lab. (ICSL) has been involved in research into the development of a series of PACS workstations since the middle 1980's. The most recent research, a joint UW-IBM project, attempted to create a diagnostic radiology workstation using an IBM RISC System 6000 (RS6000) computer workstation and the X-Window system. While the results are encouraging, there are inherent limitations in the workstation hardware which prevent it from providing an acceptable level of functionality for diagnostic radiology. Realizing the RS6000 workstation's limitations, a parallel effort was initiated to design a workstation, UWGSP6 (Univ. of Washington Graphics System Processor #6), that provides the required functionality. This paper documents the design of UWGSP6, which not only addresses the requirements for a diagnostic radiology workstation in terms of display resolution, response time, etc., but also includes the processing performance necessary to support key functions needed in the implementation of algorithms for computer-aided diagnosis. The paper includes a description of the workstation architecture, and specifically its image processing subsystem. Verification of the design through hardware simulation is then discussed, and finally, performance of selected algorithms based on detailed simulation is provided.

  14. Pulmonary atelectasis in newborns with clinically treatable diseases who are on mechanical ventilation: clinical and radiological aspects.

    PubMed

    Dominguez, Mariana Chiaradia; Alvares, Beatriz Regina

    2018-01-01

    To analyze the radiological aspects of pulmonary atelectasis in newborns on mechanical ventilation and treated in an intensive care unit, associating the characteristics of atelectasis with the positioning of the head and endotracheal tube seen on the chest X-ray, as well as with the clinical variables. This was a retrospective cross-sectional study of 60 newborns treated between 1985 and 2015. Data were collected from medical records and radiology reports. To identify associations between variables, we used Fisher's exact test. The level of significance was set at p < 0.05. The clinical characteristics associated with improper positioning of the endotracheal tube were prematurity and a birth weight of less than 1000 g. Among the newborns evaluated, the most common comorbidity was hyaline membrane disease. Atelectasis was seen most frequently in the right upper lobe, although cases of total atelectasis were more common in the left lung. Malpositioning of the head showed a trend toward an association with atelectasis in the left upper lobe. Pulmonary atelectasis is a common complication in newborns on mechanical ventilation. Radiological evaluation of the endotracheal tube placement provides relevant information for the early correction of this condition.

  15. Informatics in radiology: automated Web-based graphical dashboard for radiology operational business intelligence.

    PubMed

    Nagy, Paul G; Warnock, Max J; Daly, Mark; Toland, Christopher; Meenan, Christopher D; Mezrich, Reuben S

    2009-11-01

    Radiology departments today are faced with many challenges to improve operational efficiency, performance, and quality. Many organizations rely on antiquated, paper-based methods to review their historical performance and understand their operations. With increased workloads, geographically dispersed image acquisition and reading sites, and rapidly changing technologies, this approach is increasingly untenable. A Web-based dashboard was constructed to automate the extraction, processing, and display of indicators and thereby provide useful and current data for twice-monthly departmental operational meetings. The feasibility of extracting specific metrics from clinical information systems was evaluated as part of a longer-term effort to build a radiology business intelligence architecture. Operational data were extracted from clinical information systems and stored in a centralized data warehouse. Higher-level analytics were performed on the centralized data, a process that generated indicators in a dynamic Web-based graphical environment that proved valuable in discussion and root cause analysis. Results aggregated over a 24-month period since implementation suggest that this operational business intelligence reporting system has provided significant data for driving more effective management decisions to improve productivity, performance, and quality of service in the department.

  16. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology.

    PubMed

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Schoepf, U Joseph; Xu, Jiaqian; Lu, Guang Ming; Li, Enzhong

    2017-10-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. • Radiology research in Mainland China saw a substantial increase. • Neuroradiology, vascular/interventional Radiology, and abdominal Radiology are the most productive fields. • MRI is the most used modality in Mainland China's Radiology research. • Guangdong, Shanghai, and Beijing are the most productive provinces.

  17. The Semipalatinsk nuclear test site: a first assessment of the radiological situation and the test-related radiation doses in the surrounding territories.

    PubMed

    Gusev, B I; Abylkassimova, Z N; Apsalikov, K N

    1997-09-01

    As a result of atmospheric nuclear tests at the Semipalatinsk test site 'Polygon', adjacent territories were contaminated by radionuclide fallout. The population of some districts in the Semipalatinsk oblast were exposed to elevated levels of radiation. Contamination and exposure mostly resulted from early atmospheric tests. The radiological situation of the Semipalatinsk oblast is described. Effective dose estimates due to external and internal exposure attributable to the 1949 and 1953 tests in villages near the Polygon range from 70 mSv to 4470 mSv.

  18. USING THE HERMITE POLYNOMIALS IN RADIOLOGICAL MONITORING NETWORKS.

    PubMed

    Benito, G; Sáez, J C; Blázquez, J B; Quiñones, J

    2018-03-15

    The most interesting events in Radiological Monitoring Network correspond to higher values of H*(10). The higher doses cause skewness in the probability density function (PDF) of the records, which there are not Gaussian anymore. Within this work the probability of having a dose >2 standard deviations is proposed as surveillance of higher doses. Such probability is estimated by using the Hermite polynomials for reconstructing the PDF. The result is that the probability is ~6 ± 1%, much >2.5% corresponding to Gaussian PDFs, which may be of interest in the design of alarm level for higher doses.

  19. [Evaluation of the radiological, biochemical and serological parameters of patients prediagnosed as cystic echinococcosis in Çorum, Turkey].

    PubMed

    Güreser, A Semra; Özcan, Oğuzhan; Özünel, Leyla; Boyacıoğlu, Zehra İlkay; Taylan Özkan, Ayşegül

    2015-04-01

    Cystic echinococcosis (CE) is a zoonosis caused by Echinococcus granulosus. It is difficult to diagnose CE by clinical symptoms alone, therefore, radiological and serological examinations should be conducted as well. The aims of this retrospective study were to evaluate the biochemical, hemogram, serological and radiological findings of patients prediagnosed as CE, and to survey epidemiological data to detect the status of the disease in our region. A total of 253 patients (148 female, 105 male) who were admitted to Hitit University Training and Research Hospital in Corum province (located in the central Black Sea Region of Turkey), between October 2009 to July 2013, were included in the study. Serum samples collected from the patients were analyzed by indirect hemagglutination (IHA) test, in the Microbiology Reference Laboratories of the Turkish Public Health Institute, and 1/160 and higher titers were considered positive. Twenty-three (15.5%) of female patients and nine (8.6%) of male patients, with a total of 32 (12.7%) were found to be seropositive. The difference between the gender was not statistically significant (X2= 2.72). The age range of the 32 seropositive patients was between 16-90 years (mean: 51), and of them 24 (75%) being over 40 years old was found as statistically significant (X2= 22.45). All of the seropositive patients presented radiological findings diagnosed with ultrasonography and computed tomography. Additionally, it was noticed that two patients (one male, one female) who were seronegative by IHA test, have passed a CE operation and the diagnosis was confirmed with pathological findings. Of the patients 43.8% were admitted to general surgery, followed by infectious diseases (21.9%), gastroenterology (21.9%) and other (12.5%) clinics. Radiological diagnosis showed that 31 (96.9%) of seropositive patients had CE in the liver, of them two (6.3%) also had lung involvement, while one patient (3.1%) had intraperitoneal involvement alone, without liver infection. Although 50% (16/32) of patients resided in Çorum urban area, most of them were dealing with agriculture and animal breeding. Among the biochemical parameters, GGT were detected with highest level (28%), followed by ALT (16%), AST (16%) and ALP (13%), while the other parameters were normal. Elevated RDW level was the most frequently observed result (29%) among hemogram parameters, while decreased levels of hematocrit, hemoglobin and MCV were detected in 23%, 19% and 19% of the patients, respectively. Eosinophilia was detected in 19% of the patients. In conclusion, for the diagnosis of CE, which is still an important public health problem in our region, a comprehensive evaluation of clinical, radiological, serological and biochemical findings is needed, to avoid a confusion of other diseases with similar clinical symptoms.

  20. Site environmental report for Calendar Year 1994 on radiological and nonradiological parameters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-06-30

    Battelle Memorial Institute`s nuclear research facilities are currently being maintained in a surveillance and maintenance (S&M) mode with continual decontamination and decommissioning (D&D) activities being conducted under Department of Energy (DOE) Contract W-7405-ENG-92. These activities are referred to under the Contract as the Battelle Columbus Laboratories Decommissioning Project (BCLDP). Operations referenced in this report are performed in support of S&M and D&D activities. Battelle`s King Avenue facility is not considered in this report to the extent that the West Jefferson facility is. The source term at the King Avenue site is a small fraction of the source term at themore » West Jefferson site. Off site levels of radionuclides that could be attributed to the west Jefferson and King Avenue nuclear operations wereindistinguishable from background levels at specific locations where air, water, and direct radiation measurements were performed. Environmental monitoring continued to demonstrate compliance by Battelle with federal, state and local regulations. Routine, nonradiological activities performed include monitoring liquid effluents and monitoring the ground water system for the West Jefferson North site. Samples of various environmental media including air, water, grass, fish, field and garden crops, sediment and soil were collected from the region surrounding the two sites and analyzed.« less

  1. Status Update on the NCRP Scientific Committee SC 5-1 Report: Decision Making for Late-Phase Recovery from Nuclear or Radiological Incidents - 13450

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, S.Y.

    2013-07-01

    In August 2008, the U.S. Department of Homeland Security (DHS) issued its final Protective Action Guide (PAG) for radiological dispersal device (RDD) and improvised nuclear device (IND) incidents. This document specifies protective actions for public health during the early and intermediate phases and cleanup guidance for the late phase of RDD or IND incidents, and it discusses approaches to implementing the necessary actions. However, while the PAG provides specific guidance for the early and intermediate phases, it prescribes no equivalent guidance for the late-phase cleanup actions. Instead, the PAG offers a general description of a complex process using a site-specificmore » optimization approach. This approach does not predetermine cleanup levels but approaches the problem from the factors that would bear on the final agreed-on cleanup levels. Based on this approach, the decision-making process involves multifaceted considerations including public health, the environment, and the economy, as well as socio-political factors. In an effort to fully define the process and approach to be used in optimizing late-phase recovery and site restoration following an RDD or IND incident, DHS has tasked the NCRP with preparing a comprehensive report addressing all aspects of the optimization process. Preparation of the NCRP report is a three-year (2010-2013) project assigned to a scientific committee, the Scientific Committee (SC) 5-1; the report was initially titled, Approach to Optimizing Decision Making for Late- Phase Recovery from Nuclear or Radiological Terrorism Incidents. Members of SC 5-1 represent a broad range of expertise, including homeland security, health physics, risk and decision analysis, economics, environmental remediation and radioactive waste management, and communication. In the wake of the Fukushima nuclear accident of 2011, and guided by a recent process led by the White House through a Principal Level Exercise (PLE), the optimization approach has since been expanded to include off-site contamination from major nuclear power plant accidents as well as other nuclear or radiological incidents. The expanded application under the current guidance has thus led to a broadened scope of the report, which is reflected in its new title, Decision Making for Late-Phase Recovery from Nuclear or Radiological Incidents. The NCRP report, which is due for publication in 2013, will substantiate the current DHS guidance by clarifying and elaborating on the processes required for the development and implementation of procedures for optimizing decision making for late-phase recovery, enabling the establishment of cleanup goals on a site-specific basis. The report will contain a series of topics addressing important issues related to the long-term recovery from nuclear or radiological incidents. Special topics relevant to supporting the optimization of the decision-making process will include cost-benefit analysis, radioactive waste management, risk communication, stakeholder interaction, risk assessment, and decontamination approaches and techniques. The committee also evaluated past nuclear and radiological incidents for their relevance to the report, including the emerging issues associated with the Fukushima nuclear accident. Thus, due to the commonality of the late-phase issues (such as the potential widespread contamination following an event), the majority of the information pertaining to the response in the late-phase decision-making period, including site-specific optimization framework and approach, could be used or adapted for use in case of similar situations that are not due to terrorism, such as those that would be caused by major nuclear facility accidents or radiological incidents. To ensure that the report and the NCRP recommendations are current and relevant to the effective implementation of federal guidance, SC 5-1 has actively coordinated with the agencies of interest and other relevant stakeholders throughout the duration of the project. The resulting report will be an important resource to guide those involved in late-phase recovery efforts following a nuclear or radiological incident. (authors)« less

  2. Cryptococcal Meningoencephalitis Relapse after an 8 Year Delay: An Interplay of Infection and Immune Reconstitution?

    PubMed Central

    Katchanov, Juri; Blechschmidt, Cristiane; Nielsen, Kirsten; Branding, Gordian; Arastéh, Keikawus; Tintelnot, Kathrin; Meintjes, Graeme; Boulware, David R.; Stocker, Hartmut

    2016-01-01

    We report a case of a symptomatic relapse of HIV-related cryptococcal meningoencephalitis 8 years after the first diagnosis on the background of immune reconstitution. The findings as well as the clinical course suggests a combination of smouldering localized infection and enhanced inflammatory reaction related to immune restoration due to antiretroviral therapy. A combination of antifungal and anti-inflammatory therapy resulted in clinical and radiological improvement. Our case challenges the concept that immune reconstitution inflammatory syndrome and microbiological relapse are dichotomous entities. PMID:25505049

  3. [Statistical analysis of German radiologic periodicals: developmental trends in the last 10 years].

    PubMed

    Golder, W

    1999-09-01

    To identify which statistical tests are applied in German radiological publications, to what extent their use has changed during the last decade, and which factors might be responsible for this development. The major articles published in "ROFO" and "DER RADIOLOGE" during 1988, 1993 and 1998 were reviewed for statistical content. The contributions were classified by principal focus and radiological subspecialty. The methods used were assigned to descriptive, basal and advanced statistics. Sample size, significance level and power were established. The use of experts' assistance was monitored. Finally, we calculated the so-called cumulative accessibility of the publications. 525 contributions were found to be eligible. In 1988, 87% used descriptive statistics only, 12.5% basal, and 0.5% advanced statistics. The corresponding figures in 1993 and 1998 are 62 and 49%, 32 and 41%, and 6 and 10%, respectively. Statistical techniques were most likely to be used in research on musculoskeletal imaging and articles dedicated to MRI. Six basic categories of statistical methods account for the complete statistical analysis appearing in 90% of the articles. ROC analysis is the single most common advanced technique. Authors make increasingly use of statistical experts' opinion and programs. During the last decade, the use of statistical methods in German radiological journals has fundamentally improved, both quantitatively and qualitatively. Presently, advanced techniques account for 20% of the pertinent statistical tests. This development seems to be promoted by the increasing availability of statistical analysis software.

  4. Preoperative radiological factors correlated to long-term recurrence of hallux valgus following distal chevron osteotomy.

    PubMed

    Pentikainen, Ilkka; Ojala, Risto; Ohtonen, Pasi; Piippo, Jouni; Leppilahti, Juhana

    2014-12-01

    The purpose of this article was to analyze the long-term radiologic results after distal chevron osteotomy for hallux valgus treatment and to determine the preoperative radiographic factors correlating with radiological recurrence of the deformity. The study included 100 consecutive patients who received distal chevron osteotomy for hallux valgus. The osteotomy included fixation with an absorbable pin in 50 cases, and no fixation in the other 50. For 6 weeks postoperatively, half of each group used a soft cast and half had a traditional elastic bandage. Weight-bearing radiographs were evaluated at 6 weeks, 6 months, 1 year, and a mean of 7.9 (range, 5.8-9.4) years postoperatively. At the final follow-up, radiological recurrence of hallux valgus deformity (HVA > 15 degrees) was observed in 56 feet (73%). Eleven feet (14%) had mild recurrence (HVA < 20 degrees), 44 (57%) moderate (20 degrees ≥ HVA < 40 degrees), and 1 (1%) severe (HVA ≥ 40 degrees). All recurrences were painless, and thus no revision surgery was required. Long-term hallux valgus recurrence was significantly affected by preoperative congruence, DMAA, sesamoid position, HVA, and I/II IMA. Radiological recurrence of hallux valgus deformity of 15 degrees or more was very common at long-term follow-up after distal chevron osteotomy. Preoperative congruence, DMAA, sesamoid position (LaPorta), HVA, and I/II IMA significantly affected recurrence. Level III, comparative case series. © The Author(s) 2014.

  5. TRENCADIS--a WSRF grid MiddleWare for managing DICOM structured reporting objects.

    PubMed

    Blanquer, Ignacio; Hernandez, Vicente; Segrelles, Damià

    2006-01-01

    The adoption of the digital processing of medical data, especially on radiology, has leaded to the availability of millions of records (images and reports). However, this information is mainly used at patient level, being the extraction of information, organised according to administrative criteria, which make the extraction of knowledge difficult. Moreover, legal constraints make the direct integration of information systems complex or even impossible. On the other side, the widespread of the DICOM format has leaded to the inclusion of other information different from just radiological images. The possibility of coding radiology reports in a structured form, adding semantic information about the data contained in the DICOM objects, eases the process of structuring images according to content. DICOM Structured Reporting (DICOM-SR) is a specification of tags and sections to code and integrate radiology reports, with seamless references to findings and regions of interests of the associated images, movies, waveforms, signals, etc. The work presented in this paper aims at developing of a framework to efficiently and securely share medical images and radiology reports, as well as to provide high throughput processing services. This system is based on a previously developed architecture in the framework of the TRENCADIS project, and uses other components such as the security system and the Grid processing service developed in previous activities. The work presented here introduces a semantic structuring and an ontology framework, to organise medical images considering standard terminology and disease coding formats (SNOMED, ICD9, LOINC..).

  6. Coordinating patient care within radiology and across the enterprise.

    PubMed

    McEnery, Kevin W

    2014-12-01

    For the practice of radiology, the transition to filmless imaging operations has resulted in a fundamental transition to more efficient clinical operations. In addition, the electronic delivery of diagnostic studies to the bedside has had a great impact on the care process throughout the health care enterprise. The radiology information system (RIS) has been at the core of the transition to filmless patient care. In a similar manner, the electronic medical record (EMR) is fundamentally and rapidly transforming the clinical enterprise into paperless/digital coordination of care. The widespread availability of EMR systems can be predicted to continue to increase the level of coordination of clinical care within the EMR framework. For the radiologist, readily available clinical information at the point of interpretation will continue to drive the evolution of the interpretation process, leading to improved patient outcomes. Regardless of practice size, efficient workflow processes are required to best leverage the functionality of IT systems. The radiologist should be aware of the scope of the RIS capabilities that allow for maximizing clinical benefit, and of the EMR system capabilities for improving = clinical imaging practice and care coordination across the enterprise. Radiology departments should be actively involved in forming practice patterns that allow efficient EMR-based clinical practice. This summary article is intended to assist radiologists in becoming active participants in the evolving role of both the RIS and EMR systems in coordinating efficient and effective delivery across the clinical enterprise. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Low reproducibility between oral radiologists and general dentists with regards to radiographic diagnosis of caries.

    PubMed

    Pakbaznejad Esmaeili, Elmira; Pakkala, Tuomas; Haukka, Jari; Siukosaari, Päivi

    2018-04-12

    Early clinical and radiological diagnosis of dental caries is one of the fundamental objectives of clinical dentistry because of the high frequency of the disease and severe complications if caries remains untreated, especially among the elderly and patients with immunodeficiency. Dental panoramic tomography (DPT) is a common radiographic method for evaluating dentition when indicated, especially in an adult population. The aim of this study was to assess the reproducibility of diagnosis between specialists in oral radiology and general dentists with regards to caries lesions based on DPTs of adults. One-hundred DPTs taken from adult patients (average age 35) and then analyzed and reported on by 42 general dentists were then analyzed independently by two specialists in oral radiology with respect to caries lesions in the premolar and molar areas using radiographic criteria established for caries diagnosis. The general dentists versus oral radiologists were not calibrated before. Level of agreement between specialists and general dentists was measured using Cohen's kappa. Comparison between observations of general dentists and specialists in oral radiology showed that 61% of the caries lesions on proximal surfaces of premolars and molars observed by specialists went unobserved by general dentists. Cohen's kappa value for specialists was 0.85 (p < .001) and for each specialist and general dentists 0.48 (p < .001) and 0.44 (p < .001). The reproducibility between specialists in oral radiology and general dentists for detecting caries in DPTs was low.

  8. Principles on Radiological Characterization of the Unit 1 at Ignalina NPP for Decommissioning Purposes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poskas, P.; Zujus, R.; Drumstas, G.

    There is only one nuclear power plant in Lithuania - Ignalina NPP (INPP). The INPP operated two similar units with installed capacity of 1500 MW(each). They were commissioned in 12/1983 and 08/1987, and the original design lifetime was projected out to 2010 and 2015 respectively. But the first Unit of Ignalina NPP was shutdown December 31, 2004, and second Unit will be closed down before 2010 taking into consideration substantial long-term financial assistance from the EU, G7 and other states as well as international institutions. Implementation of dismantling activities requires detailed knowledge of the radiological situation at the Unit 1.more » General Programme of Radiological Survey for Ignalina NPP Unit 1 based on NUREG-1575 was prepared in 2005- 2006 by Consortium led by Lithuanian Energy Institute and approved by Regulatory Bodies. It includes such main steps as historical site assessment, scoping, characterization, remedial actions/decontamination support surveys and final status surveys. General Programme of Radiological Survey defines content and principles of the surveys, and preliminary survey considerations, including identification of the contaminants, establishment of the free release levels, principles on areas classification depending on contamination potential, identification of the final survey units, criteria for selection survey instrumentation, techniques and methods etc. So, in the paper information on these principles and the content of the different stages in General Programme of Radiological Survey is presented. (authors)« less

  9. Assessment of radiation protection awareness and knowledge about radiological examination doses among Italian radiographers.

    PubMed

    Paolicchi, F; Miniati, F; Bastiani, L; Faggioni, L; Ciaramella, A; Creonti, I; Sottocornola, C; Dionisi, C; Caramella, D

    2016-04-01

    To evaluate radiation protection basic knowledge and dose assessment for radiological procedures among Italian radiographers A validated questionnaire was distributed to 780 participants with balanced demographic characteristics and geographic distribution. Only 12.1 % of participants attended radiation protection courses on a regular basis. Despite 90 % of radiographers stating to have sufficient awareness of radiation protection issues, most of them underestimated the radiation dose of almost all radiological procedures. About 5 % and 4 % of the participants, respectively, claimed that pelvis magnetic resonance imaging and abdominal ultrasound exposed patients to radiation. On the contrary, 7.0 % of the radiographers stated that mammography does not use ionising radiation. About half of participants believed that radiation-induced cancer is not dependent on age or gender and were not able to differentiate between deterministic and stochastic effects. Young radiographers (with less than 3 years of experience) showed a higher level of knowledge compared with the more experienced radiographers. There is a substantial need for radiographers to improve their awareness of radiation protection issues and their knowledge of radiological procedures. Specific actions such as regular training courses for both undergraduate and postgraduate students as well as for working radiographers must be considered in order to assure patient safety during radiological examinations. • Radiographers should improve their knowledge on radiation protection issues. • Only 12.1 % of participants attended radiation protection courses on a regular basis. • Specific actions must be considered in order to increase knowledge and awareness.

  10. Correlation of matrix metalloproteinase (MMP)-1, -2, -3, and -9 expressions with demographic and radiological features in primary lumbar intervertebral disc disease.

    PubMed

    Basaran, Recep; Senol, Mehmet; Ozkanli, Seyma; Efendioglu, Mustafa; Kaner, Tuncay

    2017-07-01

    Degeneration of IVD is a progressive and irreversible process and can be evaluated with immunohistochemical examination or radiological grading. MMPs are a family of proteolytic enzymes and involved in the degradation of the matrix components of the IVD. We aimed to compare MMP-1, -2, -3, and -9 expressions with demographic features, visual analogue scale (VAS), Oswestry Disability Index (ODI) and radiological (MRI) grades. The study involved 60 participants. We recorded data about age, complaint, radiological imaging, expression levels of MMP-1, -2, -3, and -9, ODI and VAS for back pain retrospectively. Intervertebral disc degeneration was graded on a 0-5 scale according to the Pfirrmann classification. As a result of the study, the median age was 52.09±12.74years. There were statistical significances between age and MMP-1, and MMP-2. There was a close correlation between grade and MMP-9. We found correlation between the VAS and the MMP-9 expression. In addition, there was relationship between expression of MMP-2 and MMP-1, MMP-3, MMP-9. In conclusion, the expressions of MMP-1 and -2 are increased with aging. There was no relationship between radiological evaluation of IVDD and aging. Increased expression of MMPs affected IVDD positively. The relationship with MMPs is not explained. This study adds to our understanding of the interaction between MMPs and IVDD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. The Role of Radiology in Influenza: Novel H1N1 and Lessons Learned From the 1918 Pandemic

    PubMed Central

    Mollura, Daniel J.; Morens, David M.; Taubenberger, Jeffery K.; Bray, Mike

    2012-01-01

    The pandemic of swine-origin H1N1 influenza that began in early 2009 has provided evidence that radiology can assist in the early diagnosis of severe cases, raising new opportunities for the further development of infectious disease imaging. To help define radiology’s role in present and future influenza outbreaks, it is important to understand how radiologists have responded to past epidemics and how these outbreaks influenced the development of imaging science. The authors review the role of radiology in the most severe influenza outbreak in history, the “great pandemic” of 1918, which arrived only 23 years after the discovery of x-rays. In large part because of the coincidental increase in the radiologic capacity of military hospitals for World War I, the 1918 pandemic firmly reinforced the role of radiologists as collaborators with clinicians and pathologists at an early stage in radiology’s development, in addition to producing a radical expansion of radiologic research on pulmonary infections. Radiology’s solid foundation from the 1918 experience in medical practice and research now affords significant opportunities to respond to the current H1N1 pandemic and future epidemics through similar interdisciplinary strategies that integrate imaging science with pathology, virology, and clinical studies. The broad range of current imaging capabilities will make it possible to study influenza at the cellular level, in animal models, and in human clinical trials to elucidate the pathogenesis of severe illness and improve clinical outcomes. PMID:20816630

  12. White Paper: Curriculum in Interventional Radiology.

    PubMed

    Mahnken, Andreas H; Bücker, Arno; Hohl, Christian; Berlis, Ansgar

    2017-04-01

    Purpose  Scope and clinical importance of interventional radiology markedly evolved over the last decades. Consequently it was acknowledged as independent subspecialty by the "European Union of Medical Specialists" (UEMS). Based on radiological imaging techniques Interventional Radiology is an integral part of Radiology. Materials und Methods  In 2009 the German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a structured training in Interventional Radiology. In cooperation with the German Society of Neuroradiology (DGNR) this training was extended to also cover Interventional Neuroradiology in 2012. Tailored for this training in Interventional Radiology a structured curriculum was developed, covering the scope of this modular training. Results  The curriculum is based on the DeGIR/DGNR modular training concept in Interventional Radiology. There is also an European Curriculum and Syllabus for Interventional Radiology developed by the "Cardiovascular and Interventional Radiological Society of Europe" (CIRSE). The presented curriculum in Interventional Radiology is designed to provide a uniform base for the training in Interventional Radiology in Germany, based on the competencies obtained during residency. Conclusion  This curriculum can be used as a basis for training in Interventional Radiology by all training sites. Key Points: · Interventional Radiology is an integral part of clinical radiology. · The German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a curriculum in Interventional Radiology. · This curriculum is an integrative basis for the training in interventional. Citation Format · Mahnken AH, Bücker A, Hohl C et al. White Paper: Curriculum in Interventional Radiology. Fortschr Röntgenstr 2017; 189: 309 - 311. © Georg Thieme Verlag KG Stuttgart · New York.

  13. An evaluation of clinical, radiological and three-dimensional dental tomography findings in ectodermal dysplasia cases

    PubMed Central

    Doğan, Mehmet-Sinan; Callea, Michele; Aksoy, Orhan; Clarich, Gabriella; Günay, Ayşe; Günay, Ahmet; Güven, Sedat; Maglione, Michele; Akkuş, Zeki

    2015-01-01

    Background This study aimed to review the results related to head and jaw disorders in cases of ectodermal dysplasia. The evaluation of ectodermal dysplasia cases was made by clincal examination and examination of the jaw and facial areas radiologically and on cone-beam 3-dimensional dental tomography (CBCT) images. Material and Methods In the 36 cases evaluated in the study, typical clinical findings of pure hypohidrotic ectodermal displasia (HED) were seen, such as missing teeth, dry skin, hair and nail disorders. CBCT images were obtained from 12 of the 36 cases, aged 1.5- 45 years, and orthodontic analyses were made on these images. Results The clinical and radiological evaluations determined, hypodontia or oligodontia, breathing problems, sweating problems, a history of fever, sparse hair, saddle nose, skin peeling, hypopigmentation, hyperpigmentation, finger and nail deformities, conical teeth anomalies, abnormal tooth root formation, tooth resorption in the root, gingivitis, history of epilepsy, absent lachrymal canals and vision problems in the cases which included to the study. Conclusions Ectodermal dysplasia cases have a particular place in dentistry and require a professional, multi-disciplinary approach in respect of the chewing function, orthognathic problems, growth, oral and dental health. It has been understood that with data obtained from modern technologies such as three-dimensional dental tomography and the treatments applied, the quality of life of these cases can be improved. Key words: Ectodermal dysplasia, three-dimensional dental tomography. PMID:25662550

  14. Integrated interdisciplinary training in the radiological sciences.

    PubMed

    Brenner, D J; Vazquez, M; Buonanno, M; Amundson, S A; Bigelow, A W; Garty, G; Harken, A D; Hei, T K; Marino, S A; Ponnaiya, B; Randers-Pehrson, G; Xu, Y

    2014-02-01

    The radiation sciences are increasingly interdisciplinary, both from the research and the clinical perspectives. Beyond clinical and research issues, there are very real issues of communication between scientists from different disciplines. It follows that there is an increasing need for interdisciplinary training courses in the radiological sciences. Training courses are common in biomedical academic and clinical environments, but are typically targeted to scientists in specific technical fields. In the era of multidisciplinary biomedical science, there is a need for highly integrated multidisciplinary training courses that are designed for, and are useful to, scientists who are from a mix of very different academic fields and backgrounds. We briefly describe our experiences running such an integrated training course for researchers in the field of biomedical radiation microbeams, and draw some conclusions about how such interdisciplinary training courses can best function. These conclusions should be applicable to many other areas of the radiological sciences. In summary, we found that it is highly beneficial to keep the scientists from the different disciplines together. In practice, this means not segregating the training course into sections specifically for biologists and sections specifically for physicists and engineers, but rather keeping the students together to attend the same lectures and hands-on studies throughout the course. This structure added value to the learning experience not only in terms of the cross fertilization of information and ideas between scientists from the different disciplines, but also in terms of reinforcing some basic concepts for scientists in their own discipline.

  15. Silica exposure to excavation workers during the excavation of a low level radiological waste pit and tritium disposal shafts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, K.M.

    1995-01-01

    This study evaluated the task-length average (TLA) respirable dust and respirable silica airborne concentrations to which construction workers excavating volcanic tuff at Los Alamos National Laboratory (LANL) were exposed. These workers were excavating a low level radiological waste disposal pit of final dimensions 720 feet long, 132 feet wide and 60 feet deep. The objectives of this study were as follows: (1) evaluate exposures; (2) determine if the type of machinery used affects the respirable dust concentration in the breathing zone of the worker; (3) evaluate the efficacy of wetting the pit to reduce the respirable dust exposure; and (4)more » determine if exposure increases with increasing depth of pit due to the walls of the pit blocking the cross wind ventilation.« less

  16. High frequencies of elevated alkaline phosphatase activity and rickets exist in extremely low birth weight infants despite current nutritional support

    PubMed Central

    Mitchell, Shannon M; Rogers, Stefanie P; Hicks, Penni D; Hawthorne, Keli M; Parker, Bruce R; Abrams, Steven A

    2009-01-01

    Background Osteopenia and rickets are common among extremely low birth weight infants (ELBW, <1000 g birth weight) despite current practices of vitamin and mineral supplementation. Few data are available evaluating the usual course of markers of mineral status in this population. Our objectives in this study were to determine the relationship between birth weight (BW) and peak serum alkaline phosphatase activity (P-APA) in ELBW infants and evaluate our experience with the diagnosis of rickets in these infants. Methods We evaluated all ELBW infants admitted to Texas Children's Hospital NICU in 2006 and 2007. Of 211 admissions, we excluded 98 patients who were admitted at >30 days of age or did not survive/stay for >6 weeks. Bone radiographs obtained in 32 infants were reviewed by a radiologist masked to laboratory values. Results In this cohort of 113 infants, P-APA was found to have a significant inverse relationship with BW, gestational age and serum phosphorus. In paired comparisons, P-APA of infants <600 g (957 ± 346 IU/L, n = 20) and infants 600–800 g (808 ± 323 IU/L, n = 43) were both significantly higher than P-APA of infants 800–1000 g (615 ± 252 IU/L, n = 50), p < 0.01. Thirty-two patients had radiographic evaluation for evidence of rickets, based on P-APA greater than 800 IU/L, parenteral nutrition greater than 3 to 4 weeks, or clinical suspicion. Of these, 18 showed radiologic rickets and 14 showed osteopenia without rickets. Infants with BW <600 g were more likely to have radiologic rickets (10/20 infants) compared to those with BW 600–800 g (6/43 infants) and BW 800–1000 g (2/50 infants), p < 0.01 for each. P-APA was not significantly higher in infants with radiologic rickets (1078 ± 356 IU/L) compared to those without radiologic evidence of rickets (943 ± 346, p = 0.18). Conclusion Elevation of P-APA >600 IU/L was very common in ELBW infants. BW was significantly inversely related to both P-APA and radiologic rickets. No single value of P-APA was related to radiological findings of rickets. Given the very high risk of osteopenia and rickets among ELBW infants, we recommend consideration of early screening and early mineral supplementation, especially among infants <600 g BW. PMID:19640269

  17. Function of minerals in the natural radioactivity level of Vaigai River sediments, Tamilnadu, India--spectroscopical approach.

    PubMed

    Ramasamy, V; Paramasivam, K; Suresh, G; Jose, M T

    2014-01-03

    Using Gamma ray and Fourier Transform Infrared (FTIR) spectroscopic techniques, level of natural radioactivity ((238)U, (232)Th and (40)K) and mineralogical characterization of Vaigai River sediments have been analyzed with the view of evaluating the radiation risk and its relation to available minerals. Different radiological parameters are calculated to know the entire radiological characterization. The average of activity concentrations and all radiological parameters are lower than the recommended safety limit. However, some sites are having higher radioactivity values than the safety limit. From the FTIR spectroscopic technique, the minerals such as quartz, microcline feldspar, orthoclase feldspar, kaolinite, gibbsite, calcite, montmorillonite and organic carbon are identified and they are characterized. The extinction co-efficient values are calculated to know the relative distribution of major minerals such as quartz, microcline feldspar, orthoclase feldspar and kaolinite. The calculated values indicate that the amount of quartz is higher than orthoclase feldspar, microcline feldspar and much higher than kaolinite. Crystallinity index is calculated to know the crystalline nature of quartz and the result indicates that the presence of ordered crystalline quartz in the present sediment. The role of minerals in the level of radioactivity is assessed by multivariate statistical analysis (Pearson's correlation and Cluster analysis). The statistical analysis confirms that the clay mineral kaolinite is the major factor than other major minerals to induce the important radioactivity variables such as absorbed dose rate and concentrations of (232)Th and (238)U. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. The impact of communication materials on public responses to a radiological dispersal device (RDD) attack.

    PubMed

    Rogers, M Brooke; Amlôt, Richard; Rubin, G James

    2013-03-01

    It is a common assumption that, in the event of a chemical, biological, radiological, or nuclear (CBRN) attack, a well-prepared and informed public is more likely to follow official recommendations regarding the appropriate safety measures to take. We present findings from a UK study investigating the ability of crisis communication to influence perceptions of risk and behavioral intentions in the general public in response to CBRN terrorism. We conducted a focus group study involving a scenario presented in mock news broadcasts to explore levels of public knowledge, information needs, and intended behavioral reactions to an attack involving an overt radiological dispersal device (RDD), or dirty bomb. We used the findings from these focus groups to design messages for the public that could be presented in a short leaflet. We then tested the effects of the leaflet on reactions to the same scenario in 8 further focus groups. The impact of the new messages on levels of knowledge, information needs, and intended compliance with official recommendations was assessed. The provision of information increased the perceived credibility of official messages and increased reported levels of intended compliance with advice to return to normal/stop sheltering, attend a facility for assessment and treatment, and return to a previously contaminated area after decontamination of the environment has taken place. Should a real attack with an RDD occur, having pretested messages available to address common concerns and information needs should facilitate the public health response to the attack.

  19. Design of early warning system for nuclear preparedness case study at Serpong

    NASA Astrophysics Data System (ADS)

    Farid, M. M.; Prawito, Susila, I. P.; Yuniarto, A.

    2017-07-01

    One effort to protect the environment from the increasing of potentially environmental radiation hazards as an impact of radiation discharge around nuclear facilities is by a continuous monitoring of the environmental radiation in real time It is important to disclose the dose rate information to public or authorities for radiological protection. In this research, we have designed a nuclear preparedness early warning system around the Serpong nuclear facility. The design is based on Arduino program, general packet radio service (GPRS) shield, and radio frequencies technology to transmit environmental radiation result of the measurement and meteorological data. Data was collected at a certain location at The Center for Informatics and Nuclear Strategic Zone Utilization BATAN Serpong. The system consistency models are defined by the quality of data and the level of radiation exposure in the deployed environment. Online users can access the website which displays the radiation dose on the environment marked on Google Map. This system is capable to issue an early warning emergency when the dose reaches three times of the background radiation exposure value, 250 nSv/hour.

  20. Hip Resurfacing Arthroplasty in Treatment of Avascular Necrosis of the Femoral Head

    PubMed Central

    Pyda, Michał; Koczy, Bogdan; Widuchowski, Wojciech; Widuchowska, Małgorzata; Stołtny, Tomasz; Mielnik, Michał; Hermanson, Jacek

    2015-01-01

    Background Hip resurfacing is a conservative type of total hip arthroplasty but its use is controversial, especially in patients with osteonecrosis. The aim of this study was analysis of the clinical and radiographic outcomes of hip resurfacing in patients with osteonecrosis. Material/Methods Between 2007 and 2008, 30 hip resurfacing arthroplasties were performed due to osteoarthritis secondary to avascular necrosis of femoral head staged as Ficat III and IV. Patients were qualified to resurfacing arthroplasty when the extent of avascular necrosis using Kerboul’s method was <200° and the angle between avascular necrosis and head-neck junction was >20°. All patients were evaluated clinically and radiologically before and 60 months after the operation. Results The mean Harris Hip Score (HHS) score increased from 47.8 to 94.25 (p<0.05). Physical activity level (University of California, Los Angeles activity score – UCLA activity score) improved from 3.7 to 7.55 (p<0.05). No implant migration was observed. Conclusions Management of osteonecrosis of the hip with resurfacing arthroplasty seems to be effective in strictly-selected patients. PMID:25618763

  1. The cost of doing business in academic radiology departments.

    PubMed

    Novak, Ronald D; Mansoori, Bahar; Sivit, Carlos J; Ros, Pablo R

    2013-01-01

    This study identifies the major sources of overhead fees/costs and subsidies in academic radiology departments (ARDs) in the US and determines the differences between them based on geographic location or the size of their affiliated hospital. ARDs in the Northeast had the highest level of financial support from their affiliated hospitals when compared to those in the South/Southwest; however, a greater number of Midwest ARDs receive high levels of funding for teaching from their medical schools when compared to the northeast. Significantly fewer ARDs affiliated with hospitals of less than 200 beds receive subsidies for their activities when compared to those affiliated with larger hospitals. Differences in levels of overhead costs/ subsidies available to ARDs are associated with either geographic location or the size of the affiliated hospital. The reasons for these differences may be related to a variety of legal, contractual, or fiscal factors. Investigation of existing geographic and affiliate size fiscal differences and their causes by ARDs may be of benefit.

  2. Factors affecting radiographers' organizational commitment.

    PubMed

    Akroyd, Duane; Jackowski, Melissa B; Legg, Jeffrey S

    2007-01-01

    A variety of factors influence employees' attitudes toward their workplace and commitment to the organization that employs them. However, these factors have not been well documented among radiologic technologists. To determine the predictive ability of selected organizational, leadership, work-role and demographic variables on organizational commitment for a national sample of radiographers. Three thousand radiographers registered by the American Registry of Radiologic Technologists working full time in clinical settings were surveyed by mail regarding their commitment to their employers, leadership within the organization that employs them, employer support and demographic information. Overall, radiographers were found to have only a moderate level of commitment to their employers. Among the factors that significantly affected commitment were the radiographer's educational level, perceived level of organizational support, role clarity and organizational leadership. The results of this study could provide managers and supervisors with insights on how to empower and challenge radiographers and offer opportunities that will enhance radiographers' commitment to the organization, thus reducing costly turnover and improving employee performance.

  3. Influence of Cytokines and Soluble Receptors in the Quality of Life and Functional Capacity of Workers Exposed to Silica.

    PubMed

    Braz, Nayara Felicidade Tomaz; Carneiro, Ana Paula Scalia; Avelar, Núbia Carelli Pereira de; Miranda, Aline Silva de; Lacerda, Ana Cristina Rodrigues; Teixeira, Mauro Martins; Teixeira, Antônio Lúcio; Mendonça, Vanessa Amaral

    2016-03-01

    The aim of the study was to evaluate the plasma levels of inflammatory mediators in subjects exposed to silica, with and without silicosis compared with unexposed control group; and to check the association between inflammatory mediators with pulmonary function, quality of life, functional capacity, and dyspnea grade. Inflammatory mediators were measured by enzyme-linked immunosorbent assay. There were 30 subjects exposed to silica and 24 control group. Interleukin-6 plasma levels were higher in subjects exposed to silica with and without silicosis than in the control group. There was a positive correlation between radiological severity and the quality of life, whereas there was a negative correlation between radiological severity and pulmonary function. A negative correlation between sTNFR1 plasma level and functional capacity was found. Interleukin-10 was negatively correlated with the quality of life total score and was positively correlated with the functional capacity and pulmonary function.

  4. Radiological environment within an NPP after a severe nuclear accident

    NASA Astrophysics Data System (ADS)

    Andgren, Karin; Fritioff, Karin; Buhr, Anna Maria Blixt; Huutoniemi, Tommi

    2017-09-01

    The radiological environment following a severe nuclear accident can be visualised on building layouts. The direct radiation in an area (or room) can be visualized on the layout by a colouring scheme depending on the dose rate level (for example orange for high gamma dose rate level and purple for an intermediate gamma dose rate level). Following the Fukushima accident, a need for update of these layouts has been identified at the Swedish nuclear power plant of Forsmark. Shielding calculations for areas where access is desired for severe accident management have been performed. Many different sources of radiation together with different types of shielding material contribute to the dose that would be received by a person entering the area. External radiation from radioactivity within e.g. pipes and components is considered and also external radiation from radioactivity in the air (originating from diffuse leakage of the containment atmosphere). Results are presented as dose rates for relevant dose points together with a method for estimating the dose rate levels for each of the rooms of the reactor building.

  5. Dose audit for patients undergoing two common radiography examinations with digital radiology systems.

    PubMed

    İnal, Tolga; Ataç, Gökçe

    2014-01-01

    We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.

  6. Radiological characterization survey of the former Diamond Magnesium Company Company site, 720 Fairport-Nursery Road, Painesville, Ohio (DMP001, DMP002)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foley, R.D.; Carrier, R.F.

    1991-12-01

    At the request of the US Department of Energy (DOE), a group from Oak Ridge National Laboratory performed an investigative radiological survey at the former Diamond Magnesium Company (DMC) site at 720 Fairport-Nursery Road, Painesville, Ohio, in September 1990. The purpose of the survey was to determine if the site is contaminated with radioactive residues as a result of federal government operation in the development of nuclear energy for defense-related projects. The survey of the site, separate parcels of which are currently owned by the Uniroyal Chemical Company (DMP001) and the Lonza Chemical Company (DMP002), included a gamma scan overmore » the ground surface, determination of gamma exposure rates at the surface and at 1 m above the surface at grid points, collection and radionuclide analysis of soil samples, and directly measured radiation levels inside three buildings used during original DMC processing. Results of the survey revealed widespread radiological contamination outdoors on the Uniroyal property and several isolated spots of elevated radiation levels on the Lonza property. The contaminants consisted of radium, uranium, and thorium in surface and subsurface soil in concentrations exceeding DOE guidelines for the release of property for unrestricted use.« less

  7. Radiological characterization survey of the former Diamond Magnesium Company Company site, 720 Fairport-Nursery Road, Painesville, Ohio (DMP001, DMP002)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foley, R.D.; Carrier, R.F.

    At the request of the US Department of Energy (DOE), a group from Oak Ridge National Laboratory performed an investigative radiological survey at the former Diamond Magnesium Company (DMC) site at 720 Fairport-Nursery Road, Painesville, Ohio, in September 1990. The purpose of the survey was to determine if the site is contaminated with radioactive residues as a result of federal government operation in the development of nuclear energy for defense-related projects. The survey of the site, separate parcels of which are currently owned by the Uniroyal Chemical Company (DMP001) and the Lonza Chemical Company (DMP002), included a gamma scan overmore » the ground surface, determination of gamma exposure rates at the surface and at 1 m above the surface at grid points, collection and radionuclide analysis of soil samples, and directly measured radiation levels inside three buildings used during original DMC processing. Results of the survey revealed widespread radiological contamination outdoors on the Uniroyal property and several isolated spots of elevated radiation levels on the Lonza property. The contaminants consisted of radium, uranium, and thorium in surface and subsurface soil in concentrations exceeding DOE guidelines for the release of property for unrestricted use.« less

  8. ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology.

    PubMed

    Khong, P-L; Ringertz, H; Donoghue, V; Frush, D; Rehani, M; Appelgate, K; Sanchez, R

    2013-04-01

    Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities - radiography and fluoroscopy, interventional radiology, and computed tomography - are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation, use of protective shielding, optimisation of exposure factors, use of pulsed fluoroscopy, limiting fluoroscopy time, etc. Major paediatric interventional procedures should be performed by experienced paediatric interventional operators, and a second, specific level of training in radiological protection is desirable (in some countries, this is mandatory). For computed tomography, dose reduction should be optimised by the adjustment of scan parameters (such as mA, kVp, and pitch) according to patient weight or age, region scanned, and study indication (e.g. images with greater noise should be accepted if they are of sufficient diagnostic quality). Other strategies include restricting multiphase examination protocols, avoiding overlapping of scan regions, and only scanning the area in question. Up-to-date dose reduction technology such as tube current modulation, organ-based dose modulation, auto kV technology, and iterative reconstruction should be utilised when appropriate. It is anticipated that this publication will assist institutions in encouraging the standardisation of procedures, and that it may help increase awareness and ultimately improve practices for the benefit of patients. Copyright © 2012. Published by Elsevier Ltd.

  9. Imaging and radiology

    MedlinePlus

    Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...

  10. [Diagnostic radiology in the technological era. Comparison between two models].

    PubMed

    Andrade-Barreto, O A; Villa-Caballero, Leonel

    2005-01-01

    Diagnostic Radiology is a medical specialty that has played a dynamic role in the medical arena during the last three decades of the XX century. As a part of the evolution of this specialty, medicine and society at large have received diverse benefits in areas of diagnosis and for the decision making process in the clinical practice. Modern radiology has provided numerous advances and refined tools that give more convenience speed and precise diagnosis in the current medical practice. At the present time, these technologies are part of the standard of care in the US and other industrialized countries, representing the ultimate desire or goal to reach for other healthcare systems in developing countries as well. Unfortunately, many of the clinical skills in the health care personal have not evolved at the same pace of those modern technologies, conditioning a reduction in the performance of sensitive areas to the patient's interest, such as the caring, compassion and quality of health care. It is unquestionable the value and benefits that technologies such as CAT and MRI scans have brought to the standard practice in the recent time. Nonetheless, it is desirable to maintain the highest possible level of clinical skills despite the extended use of modern technologies by the health personnel, without compromising the quality of care. Yet is pending the future role and rational use for those technologies in radiology, especially in times when delivering good, reliable health care have become a priority for many health institutions worldwide. This approach would be the ultimate goal to reach in times and circumstances where health for all is the highest precious value to obtain at global level.

  11. International Perspectives on Radiology in Preventive Screening.

    PubMed

    Brus-Ramer, Marcel; Lexa, Frank J; Kassing, Pamela; McGinty, Geraldine

    2016-11-01

    Several years ago, the International Economics Committee of the ACR began a study of comparisons among nations regarding the practice of radiology. This article is the second in a series. The purpose here is to compare the use across countries of imaging modalities in the screening algorithms of a variety of common diseases. In conjunction with the initial study, this will allow radiologists to understand in greater detail how health system practices differ among a selected set of nations. In this study, a standardized survey was administered to committee members from 10 countries in the developed and developing world. As with the prior study, there were both striking differences and similarities, even among a small cohort of nations that are all (except India) members of the Organisation for Economic Co-operation and Development. For example, breast cancer screening with mammography involves similar radiographic techniques for screening evaluations and has similarly high levels of insurance coverage, but the recommended ages at initial screening and end of screening differ. Other diseases, such as lung cancer and abdominal aortic aneurysm, have variable, but overall lower, levels of estimated participation among surveyed countries and significantly lower insurance coverage. Although this data set relies on survey data from individual practitioners, it provides an important perspective of the role of radiology in screening programs. Given the increasing pressure from domestic and foreign governments to reign in health care costs, the comparative differences in screening programs, and especially their use of (often costly) imaging techniques, may be a harbinger for future health policy decisions in the United States and abroad. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  12. Inflammatory biomarkers and radiologic measurements in never-smokers with COPD: A cross-sectional study from the CODA cohort

    PubMed Central

    Lee, Hyun; Hong, Yoonki; Lim, Myoung Nam; Bak, So Hyeon; Kim, Min-Ji; Kim, Kyunga; Kim, Woo Jin; Park, Hye Yun

    2017-01-01

    Various biomarkers have emerged as potential surrogates to represent various subgroups of chronic obstructive pulmonary disease (COPD), which manifest with different phenotypes. However, the biomarkers representing never-smokers with COPD have not yet been well elucidated. The aim of this study was to evaluate the associations of certain serum and radiological biomarkers with the presence of COPD in never-smokers. To explore the associations of serum and radiological biomarkers with the presence of COPD in never-smokers, we conducted a cross-sectional patient cohort study composed of never-smokers from the COPD in Dusty Areas (CODA) cohort, consisting of subjects living in dusty areas near cement plants in South Korea. Of the 131 never-smokers in the cohort, 77 (58.8%) had COPD. There were no significant differences in the number of subjects with high levels of inflammatory biomarkers (>90th percentile of never-smokers without COPD), including white blood cell count, total bilirubin, interleukin (IL)-6, IL-8, and C-reactive protein, or radiologic measurements (including emphysema index and mean wall area percentage) between never-smokers with COPD and those without COPD. However, the number of subjects with high uric acid was significantly higher in never-smokers with COPD than never-smokers without COPD (31.2% (24/77) vs. 11.1% (6/54); p = 0.013). In addition, multivariate analysis revealed that high uric acid was significantly associated with the presence of COPD in never-smokers (adjusted relative risk: 1.63; 95% confidence interval: 1.21, 2.18; p = 0.001). Our study suggests that high serum levels of uric acid might be a potential biomarker for assessing the presence of COPD in never-smokers. PMID:29117798

  13. Contamination of X-ray Cassettes with Methicillin-resistant Staphylococcus aureus and Methicillin-resistant Staphylococcus haemolyticus in a Radiology Department

    PubMed Central

    Kim, Han-Sung; Park, Ji-Young; Koo, Hyun-Sook; Choi, Chul-Sun; Song, Wonkeun; Cho, Hyoun Chan; Lee, Kyu Man

    2012-01-01

    Background We performed surveillance cultures of the surfaces of X-ray cassettes to assess contamination with methicillin-resistant Staphylococcus aureus (MRSA). Methods The surfaces of 37 X-ray cassettes stored in a radiology department were cultured using mannitol salt agar containing 6 µg/mL oxacillin. Suspected methicillin-resistant staphylococcal colonies were isolated and identified by biochemical testing. Pulsed-field gel electrophoresis (PFGE) analysis was performed to determine the clonal relationships of the contaminants. Results Six X-ray cassettes (16.2%) were contaminated with MRSA. During the isolation procedure, we also detected 19 X-ray cassettes (51.4%) contaminated with methicillin-resistant Staphylococcus haemolyticus (MRSH), identified as yellow colonies resembling MRSA on mannitol salt agar. PFGE analysis of the MRSA and MRSH isolates revealed that most isolates of each organism were identical or closely related to each other, suggesting a common source of contamination. Conclusions X-ray cassettes, which are commonly in direct contact with patients, were contaminated with MRSA and MRSH. In hospital environments, contaminated X-ray cassettes may serve as fomites for methicillin-resistant staphylococci. PMID:22563556

  14. Cystic mass of the floor of the mouth

    PubMed Central

    Lucena-Rivero, Elizabeth-Daniela; Brunet-Garcia, Laia; Faubel-Serra, Marta

    2018-01-01

    Background Epidermoid and dermoid cysts in the oral cavity are relatively uncommon lesions of developmental origin. They often remain asymptomatic for years until they grow enough to interfere with speech, deglutition and less often with breathing which can pose a critical risk to the airway and require immediate surgery. Case description A case of an epidermoid cyst of the floor of the mouth affecting a 37-year-old man is presented; this lesion was surgically enucleated with an intraoral approach. Patient did well postoperatively and there was no evidence of recurrence up to 2 years of follow up. Clinical implications Floor of the mouth is a challenging site for the diagnosis of a broad variety of lesions which the surgeon should be aware. Depending on the anatomical relation to the muscles of the floor of the mouth dermoid cysts are classified as supramylohyoid or inframylohyoid, and they will both have different clinical and radiological features. This article also includes literature review about the etiopathological, clinical, radiological and histological features, the differential diagnosis and its treatment. Key words:Epidermoid cyst, dermoid cyst, floor of mouth. PMID:29721231

  15. Exogenous lipoid pneumonia – a case report of a fire-eater

    PubMed Central

    Pielaszkiewicz-Wydra, Magdalena; Homola-Piekarska, Bożena; Szcześniak, Ewa; Ciołek-Zdun, Monika; Fall, Andrzej

    2012-01-01

    Summary Background: Exogenous lipoid pneumonia is an uncommon condition caused by inhalation or aspiration of a fatty substance. It usually presents as chronic respiratory illness mimicking interstitial lung diseases. Acute exogenous lipoid pneumonia is uncommon and typically is caused by an episode of aspiration of a large quantity of a petroleum-based product. Radiological findings vary and may imitate many other diseases. Case Report: We present a rare case of acute exogenous lipoid pneumonia in a fire-eater who aspirated liquid paraffin during his flame-blowing show (fire-eater’s lung). He was admitted to the hospital with productive cough, fever, hemoptysis, chest pain and dyspnea. Diagnosis was made on the basis of history of exposure to fatty substance, characteristic findings in CT examination and presence of lipid-laden macrophages in bronchoalveolar lavage fluid. Conclusions: Acute exogenous lipoid pneumonia is a very rare disease that typically occurs in fire-eaters and is called a fire-eater’s lung. The diagnosis is made on the basis of typical history and radiological, as well as histopathological findings. PMID:23269939

  16. Evaluation of discrepancies between thermoluminescent dosimeter and direct-reading dosimeter results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaw, K.R.

    1993-07-01

    Currently at Oak Ridge National Laboratory (ORNL), the responses of thermoluminescent dosimeters (TLDs) and direct-reading dosimeters (DRDs) are not officially compared or the discrepancies investigated. However, both may soon be required due to the new US Department of Energy (DOE) Radiological Control Manual. In the past, unofficial comparisons of the two dosimeters have led to discrepancies of up to 200%. This work was conducted to determine the reasons behind such discrepancies. For tests conducted with the TLDs, the reported dose was most often lower than the delivered dose, while DRDs most often responded higher than the delivered dose. Trends weremore » identified in personnel DRD readings, and ft was concluded that more training and more control of the DRDs could improve their response. TLD responses have already begun to be improved; a new background subtraction method was implemented in April 1993, and a new dose algorithm is being considered. It was concluded that the DOE Radiological Control Manual requirements are reasonable for identifying discrepancies between dosimeter types, and more stringent administrative limits might even be considered.« less

  17. Radiological and practical aspects of body packing

    PubMed Central

    Reginelli, A; Pinto, F; Sica, G; Scaglione, M; Berger, F H; Romano, L; Brunese, L

    2014-01-01

    Body packing represents the concealment of illegal substances in a person's body with the aim of smuggling. “Body packers” either swallow drug-filled packets or introduce drug-filled packets into their bodies rectally or vaginally with the purpose of concealing them. The three main smuggled drugs are cocaine, heroin and cannabis products. Body packing represents a serious risk of acute narcotic toxicity from drug exposure, intestinal obstruction owing to pellet impaction and bowel perforation with consequent abdominal sepsis. A suspected body packer is generally admitted to hospital to perform imaging investigations and confirm the presence of drugs in his/her body. Radiological imaging methods are essential to diagnose body packing and to detect potential complications. Increasing sophistication of traffickers and improvements in packaging add to the detection difficulty. Radiologists should be aware of the appearance of drug packets in a range of imaging modalities. This article informs physicians about the challenging aspects of body packing, its background and medicolegal issues, what imaging methods can be used and what criteria are necessary to perform a correct diagnosis. PMID:24472727

  18. Radiological monitoring plan for the Oak Ridge Y-12 Plant: Surface Water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-10-01

    The Y-12 Plant conducts a surface water monitoring program in response to DOE Orders and state of Tennessee requirements under the National Pollutant Discharge Elimination System (NPDES). The anticipated codification of DOE Order 5400.5 for radiation protection of the public and the environment (10 CFR Part 834) will require an environmental radiation protection plan (ERPP). The NPDES permit issued by the state of Tennessee requires a radiological monitoring plan (RMP) for Y-12 Plant surface waters. In a May 4, 1995 memo, the state of Tennessee, Division of Water Pollution Control, stated their desired needs and goals regarding the content ofmore » RMPs, associated documentation, and data resulting from the RMPs required under the NPDES permitting system (L. Bunting, General Discussion, Radiological Monitoring Plans, Tennessee Division of Water Pollution Control, May 4,1995). Appendix A provides an overview of how the Y-12 Plant will begin to address these needs and goals. It provides a more complete, documented basis for the current Y-12 Plant surface water monitoring program and is intended to supplement documentation provided in the Annual Site Environmental Reports (ASERs), NPDES reports, Groundwater Quality Assessment Reports, and studies conducted under the Y-12 Plant Environmental Restoration (ER) Program. The purpose of this update to the Y-12 Plant RMP is to satisfy the requirements of the current NPDES permit, DOE Order 5400.5, and 10 CFR Part 834, as current proposed, by defining the radiological monitoring plan for surface water for the Y-12 Plant. This plan includes initial storm water monitoring and data analysis. Related activities such as sanitary sewer and sediment monitoring are also summarized. The plan discusses monitoring goals necessary to determine background concentrations of radionuclides, to quantify releases, determine trends, satisfy regulatory requirements, support consequence assessments, and meet requirements that releases be ``as low as reasonably achievable`` (ALARA).« less

  19. Improving Radiation Awareness and Feeling of Personal Security of Non-Radiological Medical Staff by Implementing a Traffic Light System in Computed Tomography.

    PubMed

    Heilmaier, C; Mayor, A; Zuber, N; Fodor, P; Weishaupt, D

    2016-03-01

    Non-radiological medical professionals often need to remain in the scanning room during computed tomography (CT) examinations to supervise patients in critical condition. Independent of protective devices, their position significantly influences the radiation dose they receive. The purpose of this study was to assess if a traffic light system indicating areas of different radiation exposure improves non-radiological medical staff's radiation awareness and feeling of personal security. Phantom measurements were performed to define areas of different dose rates and colored stickers were applied on the floor according to a traffic light system: green = lowest, orange = intermediate, and red = highest possible radiation exposure. Non-radiological medical professionals with different years of working experience evaluated the system using a structured questionnaire. Kruskal-Wallis and Spearman's correlation test were applied for statistical analysis. Fifty-six subjects (30 physicians, 26 nursing staff) took part in this prospective study. Overall rating of the system was very good, and almost all professionals tried to stand in the green stickers during the scan. The system significantly increased radiation awareness and feeling of personal protection particularly in staff with ≤ 5 years of working experience (p < 0.05). The majority of non-radiological medical professionals stated that staying in the green stickers and patient care would be compatible. Knowledge of radiation protection was poor in all groups, especially among entry-level employees (p < 0.05). A traffic light system in the CT scanning room indicating areas with lowest, intermediate, and highest possible radiation exposure is much appreciated. It increases radiation awareness, improves the sense of personal radiation protection, and may support endeavors to lower occupational radiation exposure, although the best radiation protection always is to re-main outside the CT room during the scan. • A traffic light system indicating areas with different radiation exposure within the computed tomography scanner room is much appreciated by non-radiological medical staff. • The traffic light system increases non-radiological medical staff's radiation awareness and feeling of personal protection. • Knowledge on radiation protection was poor in non-radiological medical staff, especially in those with few working experience. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Environmental 238U and 232Th concentration measurements in an area of high level natural background radiation at Palong, Johor, Malaysia.

    PubMed

    Ramli, A Termizi; Hussein, A Wahab M A; Wood, A Khalik

    2005-01-01

    Concentrations of uranium-238 and thorium-232 in soil, water, grass, moss and oil-palm fruit samples collected from an area of high background radiation were determined using neutron activation analysis (NAA). U-238 concentration in soil ranged from 4.9 mg kg(-1) (58.8 Bq kg(-1)) to 40.4 mg kg(-1) (484.8 Bq kg(-1)), Th-232 concentration ranged from 14.9 mg kg(-1) (59.6 Bq kg(-1)) to 301.0 mg kg(-1) (1204 Bq kg(-1)). The concentration of U-238 in grass samples ranged from below the detection limit to 0.076 mg kg(-1) (912 mBq kg(-1)), and Th-232 ranged from 0.008 mg kg(-1) (32 mBq kg(-1)) to 0.343 mg kg(-1) (1.372 Bq kg(-1)). U-238 content in water samples ranged from 0.33 mg kg(-1) (4.0 Bq L(-1)) to 1.40 mg kg(-1) (16.8 Bq L(-1)), and Th-232 ranged from 0.19 mg kg(-1) (0.76 Bq L(-1)) to 0.66 mg kg(-1) (2.64 Bq L(-1)). It can be said that the concentrations of environmental U-238 and Th-232 in grass and water samples in the study area are insignificant. Mosses were found to be possible bio-radiological indicators due to their high absorption of the heavy radioelements from the environment.

  1. [Variations of solar activity and radiation situation on board MIR station during the period 1986-1994].

    PubMed

    Bondarenko, V A; Mitrikas, V G; Tsetlin , V V

    1995-01-01

    This paper is dedicated to the analysis of the radiation situation onboard Mir station over a period of 1986-1994, there examined the main cosmophysics parameters and indices of the solar activity as well as the variations of the parameters of the earth's magnetic field and their association with the changes in the power of absorbed dose onboard the station. There noted the high levels of radiation exposure to the cosmonauts under terrestrial conditions when carrying out the roentgeno-radiologic examinations and procedures comparable or exceeding the absorbed doses during the flights. For revealing the regular associations of the radiation situation onboard the station with the parameters of solar activity there has been analyzed the time changes of average monthly values of dose power since the beginning of station functioning in 1986 until returning the fifteenth expedition to Earth. From the analyses of the results it might be assumed that the best statistical associations of average monthly power of the absorbed dose are found with the streams of protons of GCR. Wolff numbers and background stream of the radio emission of the Sun which reflects the existence of the radiation situation upon the phase of solar activity cycle. From this paper it transpires that calculating the dose loads during the period of the extreme phases of solar activity, it is possible to make between them the interpolations of time dependence by analogy with the dynamics in time of the background streams of GCR or Wolff numbers.

  2. Are Platelet-Rich Products Necessary during the Arthroscopic Repair of Full-Thickness Rotator Cuff Tears: A Meta-Analysis

    PubMed Central

    Zhang, Qiang; Ge, Heng’an; Zhou, Jiaojiao; Cheng, Biao

    2013-01-01

    Background Platelet-rich products (PRP) are widely used for rotator cuff tears. However, whether platelet-rich products produce superior clinical or radiological outcomes is controversial. This study aims to use meta-analysis to compare clinical and radiological outcomes between groups with or without platelet-rich products. Methods The Pubmed, Embase, and Cochrane library databases were searched for relevant studies published before April 20, 2013. Studies were selected that clearly reported a comparison between the use or not of platelet-rich products. The Constant, ASES, UCLA, and SST scale systems and the rotator cuff retear rate were evaluated. The weighted mean differences and relative risks were calculated using a fixed-effects model. Results Seven studies were enrolled in this meta-analysis. No significant differences were found for the Constant scale (0.73, 95% CI, −1.82 to 3.27, P = 0.58), ASES scale (−2.89, 95% CI, −6.31 to 0.53, P = 0.1), UCLA scale (−0.79, 95% CI, −2.20 to 0.63, P = 0.28), SST scale (0.34, 95% CI, −0.01 to 0.69, P = 0.05), and the overall rotator cuff retear rate (0.71, 95% CI, 0.48 to 1.05, P = 0.08). Subgroup analysis according to the initial tear size showed a lower retear rate in small- and medium-sized tears (0.33, 95% CI, 0.12 to 0.91, P = 0.03) after platelet-rich product application but no difference for large- and massive-sized tears (0.86, 95% CI, 0.60 to 1.23, P = 0.42). Conclusion In conclusion, the meta-analysis suggests that the platelet-rich products have no benefits on the overall clinical outcomes and retear rate for the arthroscopic repair of full-thickness rotator cuff tears. However, a decrease occurred in the rate of retears among patients treated with PRP for small- and medium-sized rotator cuff tears but not for large- and massive-sized tears. Level of Evidence Level II PMID:23874991

  3. Creation of a simple natural language processing tool to support an imaging utilization quality dashboard.

    PubMed

    Swartz, Jordan; Koziatek, Christian; Theobald, Jason; Smith, Silas; Iturrate, Eduardo

    2017-05-01

    Testing for venous thromboembolism (VTE) is associated with cost and risk to patients (e.g. radiation). To assess the appropriateness of imaging utilization at the provider level, it is important to know that provider's diagnostic yield (percentage of tests positive for the diagnostic entity of interest). However, determining diagnostic yield typically requires either time-consuming, manual review of radiology reports or the use of complex and/or proprietary natural language processing software. The objectives of this study were twofold: 1) to develop and implement a simple, user-configurable, and open-source natural language processing tool to classify radiology reports with high accuracy and 2) to use the results of the tool to design a provider-specific VTE imaging dashboard, consisting of both utilization rate and diagnostic yield. Two physicians reviewed a training set of 400 lower extremity ultrasound (UTZ) and computed tomography pulmonary angiogram (CTPA) reports to understand the language used in VTE-positive and VTE-negative reports. The insights from this review informed the arguments to the five modifiable parameters of the NLP tool. A validation set of 2,000 studies was then independently classified by the reviewers and by the tool; the classifications were compared and the performance of the tool was calculated. The tool was highly accurate in classifying the presence and absence of VTE for both the UTZ (sensitivity 95.7%; 95% CI 91.5-99.8, specificity 100%; 95% CI 100-100) and CTPA reports (sensitivity 97.1%; 95% CI 94.3-99.9, specificity 98.6%; 95% CI 97.8-99.4). The diagnostic yield was then calculated at the individual provider level and the imaging dashboard was created. We have created a novel NLP tool designed for users without a background in computer programming, which has been used to classify venous thromboembolism reports with a high degree of accuracy. The tool is open-source and available for download at http://iturrate.com/simpleNLP. Results obtained using this tool can be applied to enhance quality by presenting information about utilization and yield to providers via an imaging dashboard. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Federated ontology-based queries over cancer data

    PubMed Central

    2012-01-01

    Background Personalised medicine provides patients with treatments that are specific to their genetic profiles. It requires efficient data sharing of disparate data types across a variety of scientific disciplines, such as molecular biology, pathology, radiology and clinical practice. Personalised medicine aims to offer the safest and most effective therapeutic strategy based on the gene variations of each subject. In particular, this is valid in oncology, where knowledge about genetic mutations has already led to new therapies. Current molecular biology techniques (microarrays, proteomics, epigenetic technology and improved DNA sequencing technology) enable better characterisation of cancer tumours. The vast amounts of data, however, coupled with the use of different terms - or semantic heterogeneity - in each discipline makes the retrieval and integration of information difficult. Results Existing software infrastructures for data-sharing in the cancer domain, such as caGrid, support access to distributed information. caGrid follows a service-oriented model-driven architecture. Each data source in caGrid is associated with metadata at increasing levels of abstraction, including syntactic, structural, reference and domain metadata. The domain metadata consists of ontology-based annotations associated with the structural information of each data source. However, caGrid's current querying functionality is given at the structural metadata level, without capitalising on the ontology-based annotations. This paper presents the design of and theoretical foundations for distributed ontology-based queries over cancer research data. Concept-based queries are reformulated to the target query language, where join conditions between multiple data sources are found by exploiting the semantic annotations. The system has been implemented, as a proof of concept, over the caGrid infrastructure. The approach is applicable to other model-driven architectures. A graphical user interface has been developed, supporting ontology-based queries over caGrid data sources. An extensive evaluation of the query reformulation technique is included. Conclusions To support personalised medicine in oncology, it is crucial to retrieve and integrate molecular, pathology, radiology and clinical data in an efficient manner. The semantic heterogeneity of the data makes this a challenging task. Ontologies provide a formal framework to support querying and integration. This paper provides an ontology-based solution for querying distributed databases over service-oriented, model-driven infrastructures. PMID:22373043

  5. Risk of symptomatic heterotopic ossification following plate osteosynthesis in multiple trauma patients: an analysis in a level-1 trauma centre

    PubMed Central

    Zeckey, Christian; Hildebrand, Frank; Mommsen, Philipp; Schumann, Julia; Frink, Michael; Pape, Hans-Christoph; Krettek, Christian; Probst, Christian

    2009-01-01

    Background Symptomatic heterotopic ossification (HO) in multiple trauma patients may lead to follow up surgery, furthermore the long-term outcome can be restricted. Knowledge of the effect of surgical treatment on formation of symptomatic heterotopic ossification in polytrauma is sparse. Therefore, we test the effects of surgical treatment (plate osteosynthesis or intramedullary nailing) on the formation of heterotopic ossification in the multiple trauma patient. Methods We retrospectively analysed prospectively documented data of blunt multiple trauma patients with long bone fractures which were treated at our level-1 trauma centre between 1997 and 2005. Patients were distributed to 2 groups: Patients treated by intramedullary nails (group IMN) or plate osteosynthesis (group PLATE) were compared. The expression and extension of symptomatic heterotopic ossifications on 3-6 months follow-up x-rays in antero-posterior (ap) and lateral views were classified radiologically and the maximum expansion was measured in millimeter (mm). Additionally, ventilation time, prophylactic medication like indomethacine and incidence and correlation of head injuries were analysed. Results 101 patients were included in our study, 79 men and 22 women. The fractures were treated by intramedullary nails (group IMN n = 50) or plate osteosynthesis (group PLATE n = 51). Significantly higher radiologic ossification classes were detected in group PLATE (2.9 ± 1.3) as compared to IMN (2.2 ± 1.1; p = 0.013). HO size in mm ap and lateral showed a tendency towards larger HOs in the PLATE group. Additionally PLATE group showed a higher rate of articular fractures (63% vs. 28% in IMN) while IMN demonstrated a higher rate of diaphyseal fractures (72% vs. 37% in PLATE; p = 0.003). Ventilation time, indomethacine and incidence of head injuries showed no significant difference between groups. Conclusion Fracture care with plate osteosynthesis in polytrauma patients is associated with larger formations of symptomatic heterotopic ossifications (HO) while intramedullary nailing was associated with a higher rate of remote HO. For future fracture care of multiply injured patients these facts may be considered by the responsible surgeon. PMID:19825174

  6. Lumbar Disc Replacement for Junctional Decompensation After Fusion Surgery: Clinical and Radiological Outcome at an Average Follow-Up of 33 Months

    PubMed Central

    Sliwa, Karen; Weinberg, Ian R.; Sweet, Barry MBE; de Villiers, Malan; Candy, Geoffrey P.

    2007-01-01

    Background Failed fusion surgery remains difficult to treat. Few published data on disc replacement surgery after failed fusion procedures exist. Our objective was to evaluate outcomes of junctional lumbar disc replacement after previous fusion surgery and to correlate outcome with radiological changes to parameters of sagittal balance. Methods Out of a single-center prospective registry of 290 patients with 404 lumbar disc replacements, 27 patients had had a previous lumbar fusion operation on 1 to 4 lumbar segments and had completed a mean follow- up of 33 months (range: 18–56). We correlated the clinical outcome measures (patient satisfaction, 10-point pain score, and Oswestry Disability Index [ODI] score) to parameters of spinal sagittal alignment (sacral tilt, pelvic tilt, pelvic incidence, and lumbar lordosis). Results Postoperative hospital stay averaged 3.3 days (range: 2–8). Previously-employed patients went back to their jobs with a mean of 32 days (range: 21–42) after the procedure. At the latest follow-up, 1 of the patients considered the outcome to be poor, 3 fair, 8 good, and 15 excellent. Twenty-four patients “would undergo the operation again.” Average pain score decreased from 9.1 ± 1.0 (SD) to 3.2 ± 2.1 (P < .01). Average ODI decreased from 50.2 ± 9.9 preoperatively to 21.7 ± 14.2 (P ≤ .01). We found the change in pelvic tilt to be an independent predictor of better clinical outcome by multivariate analysis (P < .05). Conclusions In patients with junctional failure adjacent to a previous posterolateral fusion, disc replacement at the junctional level(s), compared with osteotomy and fusion surgery, offers the advantage of maintaining segmental mobility and correcting the flat-back deformity through a single approach with less operative time and blood loss. Early- to intermediate-term results are promising. The influence of changes in spinal sagittal alignment on clinical outcome needs to be addressed in future research. Clinical Relevance This is the first study on “junctional disc replacement patients” correlating clinical outcome to changes in spinal/pelvic alignment. PMID:25802584

  7. An Aerial Radiological Survey of Selected Areas of Area 18 - Nevada Test Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craig Lyons

    As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey of selected areas of Area 18 of the Nevada Test Site (NTS) for the purpose of mapping man-made radiation deposited as a result of the Johnnie Boy and Little Feller I tests. The survey area centered over the Johnnie Boy ground zero but also included the ground zero and deposition area of the Little Feller I test, approximately 7,000 feet (2133 meters) southeast of the Johnnie Boy site. Themore » survey was conducted in one flight. The completed survey covered a total of 4.0 square miles. The flight lines (with the turns) over the surveyed areas are presented in Figure 1. One 2.5-hour-long flight was performed at an altitude of 100 ft above ground level (AGL) with 200 foot flight-line spacing. A test-line flight was conducted near the Desert Rock Airstrip to ensure quality control of the data. The test line is not shown in Figure 1. However, Figure 1 does include the flight lines for a ''perimeter'' flight. The path traced by the helicopter flying over distinct roads within the survey area can be used to overlay the survey data on a base map or image. The flight survey lines were flown in an east-west orientation perpendicular to the deposition patterns for both sites. This technique provides better spatial resolution when contouring the data. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data, in the form of gamma energy spectra, were collected every second over the course of the survey and were geo-referenced using a differential Global Positioning System. Spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man-made radioisotopes. Spectral data can also identify specific radioactive isotopes. Based on the results of the RSL NTS 1994 surveys, this area was chosen for a resurvey to improve the spatial resolution of the reported depositions for the Johnnie Boy and Little Feller I events. In addition, the survey was expected to confirm the absence of detectable concentrations of Americium-241 (Am-241) at the Johnnie Boy site and attempt to confirm the presence of Uranium-235 (U-235).« less

  8. Peer Review in Radiology: A Resident and Fellow Perspective.

    PubMed

    Grenville, Jeffrey; Doucette-Preville, David; Vlachou, Paraskevi A; Mnatzakanian, Gevork N; Raikhlin, Antony; Colak, Errol

    2016-02-01

    The purpose of this study was to explore Canadian radiology residents' and fellows' understanding, attitudes, opinions, and preferences toward peer review. An Internet-based anonymous questionnaire designed to understand one's familiarity, attitudes, opinions, and preferences toward peer review was distributed to radiology residents and fellows across Canada. Data were analyzed using descriptive statistics, and answers were stratified by level of training. A total of 136 trainees responded to the survey with 92 completed survey responses available for descriptive statistics. Approximately half of respondents are familiar with peer review (49%), and 39% of trainees are involved in peer review. Most respondents (92%) expressed an interest in learning more about peer review; believe that it should be incorporated into the residency training curriculum (86%), be mandatory (72%), and that current participation will increase odds of future participation (91%). Most trainees (80%) are comfortable advising one another about errors, but less comfortable advising staff (21%). Residents and fellows welcome the opportunity to learn more about peer review and believe it should be incorporated into the residency training curriculum. Understanding the attitudes and perceptions held by trainees regarding peer review is important, as a means to optimize education and maximize current and future participation in peer review. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  9. A filmless radiology department in a full digital regional hospital: quantitative evaluation of the increased quality and efficiency.

    PubMed

    Nitrosi, Andrea; Borasi, Giovanni; Nicoli, Franco; Modigliani, Gino; Botti, Andrea; Bertolini, Marco; Notari, Pietro

    2007-06-01

    Reggio Emilia hospital installed Picture Archiving and Communications Systems (PACS) as the final step towards a completely digital clinical environment completing the HIS/EMR and 1,400 web/terminals for patient information access. Financial benefits throughout the hospital were assessed upfront and measured periodically. Key indicators (radiology exam turnaround time, number of radiology procedures performed, inpatients length of stay before and after the PACS implementation, etc.) were analyzed and values were statistically tested to assess workflow and productivity improvements. The hospital went "filmless" in 28 weeks. Between the half of 2004 and the respective period in 2003, overall Radiology Department productivity increased by 12%, TAT improved by more than 60%. Timelier patient care resulted in decreased lengths of stay. Neurology alone experienced a 12% improvement in average patient stay. To quantify the impact of PACS on the average hospital stays and the expected productivity benefits to inpatient productivity were used a "high level" and a "detailed" business model. Annual financial upsides have exceeded $1.9 millions/year. A well-planned PACS deployment simplifies imaging workflow and improves patient care throughout the hospital while delivering substantial financial benefits. Staff buy-in was the key in this process and on-going training and process monitoring are a must.

  10. Pulmonary atelectasis in newborns with clinically treatable diseases who are on mechanical ventilation: clinical and radiological aspects

    PubMed Central

    Dominguez, Mariana Chiaradia; Alvares, Beatriz Regina

    2018-01-01

    Objective To analyze the radiological aspects of pulmonary atelectasis in newborns on mechanical ventilation and treated in an intensive care unit, associating the characteristics of atelectasis with the positioning of the head and endotracheal tube seen on the chest X-ray, as well as with the clinical variables. Materials and Methods This was a retrospective cross-sectional study of 60 newborns treated between 1985 and 2015. Data were collected from medical records and radiology reports. To identify associations between variables, we used Fisher's exact test. The level of significance was set at p < 0.05. Results The clinical characteristics associated with improper positioning of the endotracheal tube were prematurity and a birth weight of less than 1000 g. Among the newborns evaluated, the most common comorbidity was hyaline membrane disease. Atelectasis was seen most frequently in the right upper lobe, although cases of total atelectasis were more common in the left lung. Malpositioning of the head showed a trend toward an association with atelectasis in the left upper lobe. Conclusion Pulmonary atelectasis is a common complication in newborns on mechanical ventilation. Radiological evaluation of the endotracheal tube placement provides relevant information for the early correction of this condition. PMID:29559762

  11. Manual therapy in osteoarthritis of the hip: outcome in subgroups of patients.

    PubMed

    Hoeksma, H L; Dekker, J; Ronday, H K; Breedveld, F C; Van den Ende, C H M

    2005-04-01

    To investigate whether manual therapy has particular benefit in subgroups of patients defined on the basis of hip function, range of joint motion, pain and radiological deterioration. The study was performed in the out-patient clinic of physical therapy of a large hospital. Data on 109 patients with OA of the hip (clinical ACR criteria) participating in a randomized clinical trial on the effects of manual therapy were used. The outcomes for hip function (Harris hip score), range of joint motion (ROM) and pain (VAS) were compared for specific subgroups. Subgroups were assigned by the median split method. The interaction effect between subgroup and treatment was tested using multiple regression analysis. No differences were observed in the effect of manual therapy in specific subgroups of patients defined on the basis of baseline levels of hip function, pain and ROM. On the basis of radiological grading of osteoarthritis (OA), we found that patients with severe radiological grading of OA had significantly worse outcome on ROM as a result of manual therapy than patients with mild or moderate radiological grading of OA. A significant interaction effect was found for only 1 out of 12 hypotheses investigated. Therefore, we conclude that there is no evidence for the particular benefit of manual therapy in subgroups of patients.

  12. On-line data collection platform for national dose surveys in diagnostic and interventional radiology.

    PubMed

    Vassileva, J; Simeonov, F; Avramova-Cholakova, S

    2015-07-01

    According to the Bulgarian regulation for radiation protection at medical exposure, the National Centre of Radiobiology and Radiation Protection (NCRRP) is responsible for performing national dose surveys in diagnostic and interventional radiology and nuclear medicine and for establishing of national diagnostic reference levels (DRLs). The next national dose survey is under preparation to be performed in the period of 2015-16, with the aim to cover conventional radiography, mammography, conventional fluoroscopy, interventional and fluoroscopy guided procedures and CT. It will be performed electronically using centralised on-line data collection platform established by the NCRRP. The aim is to increase the response rate and to improve the accuracy by reducing human errors. The concept of the on-line dose data collection platform is presented. Radiological facilities are provided with a tool to determine local typical patient doses, and the NCRRP to establish national DRLs. Future work will include automatic retrieval of dose data from hospital picture archival and communicating system. The on-line data collection platform is expected to facilitate the process of dose audit and optimisation of radiological procedures in Bulgarian hospitals. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Anesthesia Practices for Interventional Radiology in Europe.

    PubMed

    Vari, Alessandra; Gangi, Afshin

    2017-06-01

    The Cardiovascular and Interventional Radiological Society of Europe (CIRSE) prompted an initiative to frame the current European status of anesthetic practices for interventional radiology, in consideration of the current variability of IR suite settings, staffing and anesthetic practices reported in the literature and of the growing debate on sedation administered by non-anesthesiologists, in Europe. Anonymous online survey available to all European CIRSE members to assess IR setting, demographics, peri-procedural care, anesthetic management, resources and staffing, pain management, data collection, safety, management of emergencies and personal opinions on the role CIRSE should have in promoting anesthetic care for interventional radiology. Predictable differences between countries and national regulations were confirmed, showing how significantly many "local" factors (type and size of centers, the availability of dedicated inpatient bed, availability of anesthesia staff) can affect the routine practice and the expansion of IR as a subspecialty. In addition, the perception of the need for IR to acquire more sedation-related skills is definitely stronger for those who practice with the lowest availability of anesthesia care. Significant country variations and regulations along with a controversial position of the anesthesia community on the issue of sedation administered by non-anesthesiologists substantially represent the biggest drawbacks for the expansion of peri-procedural anesthetic care for IR and for potential initiatives at an European level.

  14. Anterior cruciate ligament reconstruction with 4-strand hamstring autograft and accelerated rehabilitation: a 10-year prospective study on clinical results, knee osteoarthritis and its predictors.

    PubMed

    Janssen, Rob P A; du Mée, Arthur W F; van Valkenburg, Juliette; Sala, Harm A G M; Tseng, Carroll M

    2013-09-01

    Analysis of long-term clinical and radiological outcomes after anterior cruciate ligament (ACL) reconstruction with special attention to knee osteoarthritis and its predictors. A prospective, consecutive case series of 100 patients. Arthroscopic transtibial ACL reconstruction was performed using 4-strand hamstring tendon autografts with a standardized accelerated rehabilitation protocol. Analysis was performed preoperatively and 10 years postoperatively. Clinical examination included Lysholm and Tegner scores, IKDC, KT-1000 testing (MEDmetric Co., San Diego, CA, USA) and leg circumference measurements. Radiological evaluation included AP weight bearing, lateral knee, Rosenberg and sky view X-rays. Radiological classifications were according to Ahlbäck and Kellgren & Lawrence. Statistical analysis included univariate and multivariate logistic regressions. RESULTS CLINICAL OUTCOME: A significant improvement (p < 0.001) between preoperative and postoperative measurements could be demonstrated for the Lysholm and Tegner scores, IKDC patient subjective assessment, KT-1000 measurements, pivot shift test, IKDC score and one-leg hop test. A pivot shift phenomenon (glide) was still present in 43 (50%) patients and correlated with lower levels of activity (p < 0.022). Radiological outcome: At follow-up, 46 (53.5%) patients had signs of osteoarthritis (OA). In this group, 33 patients (72%) had chondral lesions (≥grade 2) at the time of ACL reconstruction. A history of medial meniscectomy before or at the time of ACL reconstruction increased the risk of knee OA 4 times (95% CI 1.41-11.5). An ICRS grade 3 at the time of ACL reconstruction increased the risk of knee OA by 5.2 times (95% CI 1.09-24.8). There was no correlation between OA and activity level (Tegner score ≥6) nor between OA and a positive pivot shift test. Transtibial ACL reconstruction with 4-strand hamstring autograft and accelerated rehabilitation restored anteroposterior knee stability. Clinical parameters and patient satisfaction improved significantly. At 10-year follow-up, radiological signs of OA were present in 53.5 % of the subjects. Risk factors for OA were meniscectomy prior to or at the time of ACL reconstruction and chondral lesions at the time of ACL reconstruction. II.

  15. Radiology Undergraduate and Resident Curricula: A Narrative Review of the Literature

    PubMed Central

    Linaker, Kathleen L.

    2015-01-01

    Objective The purpose of this study was to examine the literature regarding radiology curricula for both undergraduates and residents. Methods A review of the literature was performed using relevant key words. Articles were retrieved through December 2012 using PubMed, ScienceDirect, ERIC, Proquest, and ICL databases along with a manual review of references. Results Of the 4716 unique abstracts reviewed by the author, 142 were found to be relevant to the purpose of this study. Undergraduate radiology education, radiology curriculum, and radiology pedagogy vary widely between disciplines and between colleges within disciplines. Formal radiology education is not taught at all medical programs and little radiology training is incorporated into non-radiology residencies. This results in some medical graduates not being taught how to interpret basic radiology images and not learning contraindications and indications for ordering diagnostic imaging tests. There are no definitive studies examining how to incorporate radiology into the curriculum, how to teach radiology to either undergraduates or residents, or how to assess this clinical competency. Conclusions This review shows that radiology education is perceived to be important in undergraduate and residency programs. However, some programs do not include radiology training, thus graduates from those programs do not learn radiology essentials. PMID:26770172

  16. An Integrated Interactive-Spaced Education Radiology Curriculum for Preclinical Students.

    PubMed

    Tshibwabwa, Eli; Mallin, Robert; Fraser, Madeleine; Tshibwabwa, Martin; Sanii, Reza; Rice, James; Cannon, Jenifer

    2017-01-01

    The objective of this study is to determine whether a radiology module, together with online spaced education, helps students of an integrated problem-based learning (PBL) curriculum increase their radiology knowledge and long-term retention. Second-year students at the American University of Antigua College of Medicine participated in small groups of ten students each into two 2 h of radiology laboratories. The study comprised two cohorts: winter and fall 2013 students (control group) and 2014 students (experimental group). Both groups used face-to-face PBL. The students of the experimental group received additional online-spaced education. The skills were assessed for both groups before the beginning of laboratories and 4 weeks and 7 months after laboratories. There was no significant difference on pretest between the control and experimental groups. On completion of the radiology laboratories, comparison of test results before and after training showed net improvement for both groups. The corresponding difference for the experimental group was higher compared to the one for the control group (7.83 vs. 6.21, P < 0.001). The difference between the scores on delayed test and pretest showed that the students of both groups demonstrated average knowledge improvement even though their level of performance was slightly below the posttest. The corresponding difference for the experimental group did not differ much from the posttest ( P > 0.05), and no significant difference of scores was observed 7 months later for either group. Further, a higher percentage of the students in the experimental group strongly agreed that their learning objectives were met (92% vs. 71%, P > 0.001), and this trend persisted throughout the study. Online spaced education combined to a face-to-face PBL enhances not only the student's knowledge of basic radiology along with his/her self-assessment skills but also the long-term retention of radiology material and satisfaction with the integrated interactive system-based module. Future research is needed to see if medical students in need of additional education support may benefit from spaced education in the field of remediation.

  17. The Impact Factor of Radiological Journals: Associations with Journal Content and Other Characteristics Over a Recent 12-Year Period.

    PubMed

    Rosenkrantz, Andrew B; Ayoola, Abimbola

    2016-06-01

    The aim of this study was to evaluate the trends in the impact factor (IF) of radiological journals over a recent 12-year period, including associations between IF and journal topic. Journal Citation Reports (JCR) was used to identify all biomedical journals and all radiological journals (assigned a JCR category of "Radiology, Nuclear Medicine, & Medical Imaging"), along with journal IF, in 2003 and 2014. Radiological journals were manually classified by topic. Trends in median IF (mIF) were assessed. The number of radiological journals increased from 83 (2003) to 125 (2014) (all biomedical journals: 5907 to 8718, respectively). mIF of radiological journals increased from 1.42 (2003) to 1.75 (2014) (all biomedical journals: 0.93 to 1.46, respectively). The most common topic among new radiological journals was general (nonspecialized) radiology (8). Five new radiological journals in 2014 were in topics (cancer imaging and molecular imaging) having no journals in 2003. mIF of general radiological journals was 1.49. Topics having highest mIF were cardiac imaging (2.94), optics (2.86), molecular imaging (2.77), radiation oncology (2.60), and neuroradiology (2.25). Topics with lowest mIF were ultrasound (1.19) and interventional radiology (1.44). Topics with the largest increase in mIF were cardiac imaging (from 1.17 to 2.94) and neuroradiology (from 1.07 to 2.25). Radiological journals exhibited higher mIF than biomedical journals overall. Among radiological journals, subspecialty journals had highest mIF. While a considerable number of new radiological journals since 2003 were general radiology journals having relatively low IF, there were also new journal topics representing emerging areas of subspecialized radiological research. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  18. The private-practice perspective of the manpower crisis in radiology: greener pastures?

    PubMed

    Swayne, Lawrence C

    2004-11-01

    Rising consumer expectations and a rapidly aging population point to a long-term shortage of all physicians, including radiologists. While attention has been drawn to the escalating manpower crisis in academic radiology departments, the private-practice perspective has been generally overlooked. Although clinical workloads and income are higher in private practice, studies have shown higher satisfaction levels (likely because of a greater variety of work) among academic radiologists. As the distinction between community and teaching hospitals has become increasingly blurred, there is now considerable overlap in the skill sets, sources of job satisfaction, and stresses that are encountered in both practice settings. Perhaps more than at any time in the recent past, diagnostic radiologists in academic and private practice share more in common than any perceived differences. Both groups must work together in concert with the ACR to address the growing manpower shortage, as well as the other challenges that confront diagnostic radiology at the beginning of the 21st century.

  19. Patient communication in radiology: current status of breaking bad news among radiologists and radiology trainees in Pakistan.

    PubMed

    Ali Khawaja, Ranish Deedar; Akhtar, Waseem; Khawaja, Ali; Irfan, Hira; Naeem, Mohammad; Memon, Mukhtiar

    2013-10-01

    Breaking bad news can be an intimidating task for any physician. The aim of this study was to record the practices of breaking bad news to the patients by Pakistani radiologists and trainees. The radiologists and trainees attending the 26th National Radiological Conference in October 2010 in Karachi, Pakistan, were surveyed. The response rate was 76%. The respondents included residents (51%), private practicing radiologists (28%), academic radiologists (13%), and other trainees (8%). Most of the academic radiologists communicated with their patients. The daily frequency of breaking bad news by residents was noted, which was highest in the public teaching hospitals (71%). For severe abnormalities such as malignancy, 50% residents, 55% of the academic radiologists and 74% of the private practicing radiologists were very uncomfortable in disclosure of results. Differences in frequency of communication with patients were noticed with both different training levels, and different settings of practice in a developing country.

  20. Asian Radiology Forum 2016 for Promoting Radiology Together in the Asian-Oceanian Region: Roles of the Asian-Oceanian Society of Radiology and Its Member Societies

    PubMed Central

    Kim, Ho Sung; Choi, Jung-Ah

    2018-01-01

    According to the reports presented at the second Asian Radiology Forum (ARF) 2016, organized by the Korean Society of Radiology (KSR) during the Korean Congress of Radiology (KCR) in September 2016 in Seoul, there is an increasing need for the Asian-Oceanian Society of Radiology (AOSR) and its member societies to promote radiology together in the Asian-Oceanian region. In ARF 2016, the national delegates of the Asian-Oceanian radiological partner societies primarily discussed their societies' activities and contributions in international and regional societies including AOSR, expectations for AOSR, recommendations and suggestions for AOSR, and their societies' support of AOSR. PMID:29520175

  1. A Pilot Study of Contextual UMLS Indexing to Improve the Precision of Concept-based Representation in XML-structured Clinical Radiology Reports

    PubMed Central

    Huang, Yang; Lowe, Henry J.; Hersh, William R.

    2003-01-01

    Objective: Despite the advantages of structured data entry, much of the patient record is still stored as unstructured or semistructured narrative text. The issue of representing clinical document content remains problematic. The authors' prior work using an automated UMLS document indexing system has been encouraging but has been affected by the generally low indexing precision of such systems. In an effort to improve precision, the authors have developed a context-sensitive document indexing model to calculate the optimal subset of UMLS source vocabularies used to index each document section. This pilot study was performed to evaluate the utility of this indexing approach on a set of clinical radiology reports. Design: A set of clinical radiology reports that had been indexed manually using UMLS concept descriptors was indexed automatically by the SAPHIRE indexing engine. Using the data generated by this process the authors developed a system that simulated indexing, at the document section level, of the same document set using many permutations of a subset of the UMLS constituent vocabularies. Measurements: The precision and recall scores generated by simulated indexing for each permutation of two or three UMLS constituent vocabularies were determined. Results: While there was considerable variation in precision and recall values across the different subtypes of radiology reports, the overall effect of this indexing strategy using the best combination of two or three UMLS constituent vocabularies was an improvement in precision without significant impact of recall. Conclusion: In this pilot study a contextual indexing strategy improved overall precision in a set of clinical radiology reports. PMID:12925544

  2. A pilot study of contextual UMLS indexing to improve the precision of concept-based representation in XML-structured clinical radiology reports.

    PubMed

    Huang, Yang; Lowe, Henry J; Hersh, William R

    2003-01-01

    Despite the advantages of structured data entry, much of the patient record is still stored as unstructured or semistructured narrative text. The issue of representing clinical document content remains problematic. The authors' prior work using an automated UMLS document indexing system has been encouraging but has been affected by the generally low indexing precision of such systems. In an effort to improve precision, the authors have developed a context-sensitive document indexing model to calculate the optimal subset of UMLS source vocabularies used to index each document section. This pilot study was performed to evaluate the utility of this indexing approach on a set of clinical radiology reports. A set of clinical radiology reports that had been indexed manually using UMLS concept descriptors was indexed automatically by the SAPHIRE indexing engine. Using the data generated by this process the authors developed a system that simulated indexing, at the document section level, of the same document set using many permutations of a subset of the UMLS constituent vocabularies. The precision and recall scores generated by simulated indexing for each permutation of two or three UMLS constituent vocabularies were determined. While there was considerable variation in precision and recall values across the different subtypes of radiology reports, the overall effect of this indexing strategy using the best combination of two or three UMLS constituent vocabularies was an improvement in precision without significant impact of recall. In this pilot study a contextual indexing strategy improved overall precision in a set of clinical radiology reports.

  3. PACS: implementation in the U.S. Department of Defense

    NASA Astrophysics Data System (ADS)

    Chacko, Anna K.; Wider, Ronald; Romlein, John R.; Cawthon, Michael A.; Richardson, Ronald R., Jr.; Lollar, H. William; Cook, Jay F.; Timboe, Harold L.; Johnson, Thomas G.; Fellows, Douglas W.

    2000-05-01

    The Department of Defense has been a leader in Radiology re- engineering for the past decade. Efforts have included the development of two landmark PACS specifications (MDIS and DIN- PACS), respective vendor selection and implementation programs. A Tri-Service (Army, Navy and Air Force) Radiology re-engineering program was initiated which identified transitioning to digital imaging, PACS and teleradiology as key enabling technologies in a changing business scenario. Subsequently, the systematic adjustment of procurement process for radiological imaging equipment included a focus on specifying PACS-capable-digital imaging modalities and mini- PACS as stepping stones to make the hospitals and health clinics PACS-ready. The success of the PACS and teleradiology program in the DOD is evidenced by the near filmless operation of most Army and Air Force Medical Centers, several community hospitals and several operational teleradiology constellations. Additionally, the MDIS PACSystem has become the commercial PACS product for General Electric Medical Systems. The DOD continues to forge ahead in the PACS arena by implementing advanced configurations and operational concepts such as the VRE (Virtual Radiology Environment), the negotiation of Regional Archiving and Regional PACS Maintenance Programs. Newer regulations (HIPAA, the FDA approval of digital mammography) have been promulgated impacting the culture and conduct of our business. Incorporating their requirements at the very outset will enable us to streamline the delivery of radiology. The DOD community has embraced the information age at multiple levels. The Healthcare portion of this community with these initiatives is integrating itself into DOD's future. The future holds great possibilities, promises and challenges for the DOD PACS programs.

  4. Bismuth Infusion of ABS Enables Additive Manufacturing of Complex Radiological Phantoms and Shielding Equipment.

    PubMed

    Ceh, Justin; Youd, Tom; Mastrovich, Zach; Peterson, Cody; Khan, Sarah; Sasser, Todd A; Sander, Ian M; Doney, Justin; Turner, Clark; Leevy, W Matthew

    2017-02-24

    Radiopacity is a critical property of materials that are used for a range of radiological applications, including the development of phantom devices that emulate the radiodensity of native tissues and the production of protective equipment for personnel handling radioactive materials. Three-dimensional (3D) printing is a fabrication platform that is well suited to creating complex anatomical replicas or custom labware to accomplish these radiological purposes. We created and tested multiple ABS (Acrylonitrile butadiene styrene) filaments infused with varied concentrations of bismuth (1.2-2.7 g/cm³), a radiopaque metal that is compatible with plastic infusion, to address the poor gamma radiation attenuation of many mainstream 3D printing materials. X-ray computed tomography (CT) experiments of these filaments indicated that a density of 1.2 g/cm³ of bismuth-infused ABS emulates bone radiopacity during X-ray CT imaging on preclinical and clinical scanners. ABS-bismuth filaments along with ABS were 3D printed to create an embedded human nasocranial anatomical phantom that mimicked radiological properties of native bone and soft tissue. Increasing the bismuth content in the filaments to 2.7 g/cm³ created a stable material that could attenuate 50% of 99m Technetium gamma emission when printed with a 2.0 mm wall thickness. A shielded test tube rack was printed to attenuate source radiation as a protective measure for lab personnel. We demonstrated the utility of novel filaments to serve multiple radiological purposes, including the creation of anthropomorphic phantoms and safety labware, by tuning the level of radiation attenuation through material customization.

  5. Chronic histiocytic intervillositis - Clinical, biochemical and radiological findings: An observational study.

    PubMed

    Koby, Lawrence; Keating, Sarah; Malinowski, Ann Kinga; D'Souza, Rohan

    2018-04-01

    Chronic histiocytic intervillositis (CHI) of the placenta although rare, has a high recurrence rate, is associated with serious adverse pregnancy outcomes and has no available treatment. This study aims to determine clinical, biochemical and radiological factors associated with CHI, to guide management of subsequent pregnancies. This retrospective observational study included consecutive cases with a histopathologic diagnosis of CHI after 18 weeks of gestation, between 2001 and 2014, and no controls. Clinical (maternal, fetal and delivery outcomes), biochemical (first- and second-trimester biomarkers for fetal aneuploidy and serum alkaline phosphatase) and radiological (second- and third-trimester fetal, placental and Doppler ultrasound) factors associated with a histopathological diagnosis of CHI were identified and results presented as percentages. Outcomes of subsequent pregnancies were described. Of 231 identified cases of 'intervillositis', 33 were confirmed to have CHI, of which only 4/33 (12.1%) had prior uncomplicated term deliveries. During pregnancy, 10/18 (55.5%) had abnormal first-trimester screening, 4/16 (25%) had abnormal second-trimester screening, 6/19 (31.6%) had at least one elevated alkaline phosphatase level, and 15/20 (75%) had at least one abnormal feature on mid-trimester placental ultrasound. In subsequent pregnancies that were closely followed with a combination of biochemical and radiologic tests, there were no cases of fetal loss, and lower incidence of fetal growth restriction and preterm birth. No clinical, biochemical or radiological finding is consistently associated with CHI and adverse outcomes thereof. Whether the incorporation of these tests in individualized care-plans could improve outcomes in subsequent pregnancies needs to be studied further. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Critique of the transitional year internship and its relationship to radiology residency.

    PubMed

    Baker, Stephen R; Tilak, Gauri S; Thakur, Uma

    2008-05-01

    The purpose of the study is to determine if transitional year program (TYP) requirements foster realization of standards of excellence and clinical relevance for future radiologists and to explore demographic and economic factors pertinent to TYPs. A list of accredited TYPs were obtained from the American Medical Association's Graduate Medical Education (ACGME) Directory 2006-2007. Specialty distribution of TYP graduates was examined from statistics provided by the ACGME, and data from the 2007 Main Residency Match was analyzed. Data derived from a concurrent survey of the perception of the value of internship sent to all current radiology residents and fellows was assessed. The institutional costs of employing TYP interns versus physician assistants were also calculated. Forty-one of the 125 TYPs lack residencies in internal medicine (IM), general surgery (GS), or both, and approximately two-third of these lack full medical school affiliation. The interns who will graduate from these 41 programs account for 103 of the 1,128 radiology residents in their post-graduate year 2. Despite the longest elective time offered in TYPs compared to conventional preliminary programs, current radiology trainees who had participated in preliminary IM or GS internships were more satisfied compared to trainees completing TYPs. The requirements of the transitional internship and compliance with them need to be carefully assessed to determine their efficacy. Despite the strong economic impetus for hiring TYP interns, the availability of open slots in existing preliminary programs in IM and GS, coupled with radiology residents' greater level of satisfaction with traditional over transitional internships, makes the existence of TYPs less compelling.

  7. Use of the ICRP system for the protection of marine ecosystems.

    PubMed

    Telleria, D; Cabianca, T; Proehl, G; Kliaus, V; Brown, J; Bossio, C; Van der Wolf, J; Bonchuk, I; Nilsen, M

    2015-06-01

    The International Commission on Radiological Protection (ICRP) recently reinforced the international system of radiological protection, initially focused on humans, by identifying principles of environmental protection and proposing a framework for assessing impacts of ionising radiation on non-human species, based on a reference flora and fauna approach. For this purpose, ICRP developed dosimetric models for a set of Reference Animals and Plants, which are representative of flora and fauna in different environments (terrestrial, freshwater, marine), and produced criteria based on information on radiation effects, with the aim of evaluating the level of potential or actual radiological impacts, and as an input for decision making. The approach developed by ICRP for flora and fauna is consistent with the approach used to protect humans. The International Atomic Energy Agency (IAEA) includes considerations on the protection of the environment in its safety standards, and is currently developing guidelines to assess radiological impacts based on the aforementioned ICRP approach. This paper presents the method developed by IAEA, in a series of meetings with international experts, to enable assessment of the radiological impact to the marine environment in connection with the Convention on the Prevention of Marine Pollution by Dumping of Wastes and Other Matter 1972 (London Convention 1972). This method is based on IAEA's safety standards and ICRP's recommendations, and was presented in 2013 for consideration by representatives of the contracting parties of the London Convention 1972; it was approved for inclusion in its procedures, and is in the process of being incorporated into guidelines. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  8. Moving beyond quality control in diagnostic radiology and the role of the clinically qualified medical physicist.

    PubMed

    Delis, H; Christaki, K; Healy, B; Loreti, G; Poli, G L; Toroi, P; Meghzifene, A

    2017-09-01

    Quality control (QC), according to ISO definitions, represents the most basic level of quality. It is considered to be the snapshot of the performance or the characteristics of a product or service, in order to verify that it complies with the requirements. Although it is usually believed that "the role of medical physicists in Diagnostic Radiology is QC", this, not only limits the contribution of medical physicists, but is also no longer adequate to meet the needs of Diagnostic Radiology in terms of Quality. In order to assure quality practices more organized activities and efforts are required in the modern era of diagnostic radiology. The complete system of QC is just one element of a comprehensive quality assurance (QA) program that aims at ensuring that the requirements of quality of a product or service will consistently be fulfilled. A comprehensive Quality system, starts even before the procurement of any equipment, as the need analysis and the development of specifications are important components under the QA framework. Further expanding this framework of QA, a comprehensive Quality Management System can provide additional benefits to a Diagnostic Radiology service. Harmonized policies and procedures and elements such as mission statement or job descriptions can provide clarity and consistency in the services provided, enhancing the outcome and representing a solid platform for quality improvement. The International Atomic Energy Agency (IAEA) promotes this comprehensive quality approach in diagnostic imaging and especially supports the field of comprehensive clinical audits as a tool for quality improvement. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Comprehensive Health Care Economics Curriculum and Training in Radiology Residency.

    PubMed

    Keiper, Mark; Donovan, Timothy; DeVries, Matthew

    2018-06-01

    To investigate the ability to successfully develop and institute a comprehensive health care economics skills curriculum in radiology residency training utilizing didactic lectures, case scenario exercises, and residency miniretreats. A comprehensive health care economics skills curriculum was developed to significantly expand upon the basic ACGME radiology residency milestone System-Based Practice, SBP2: Health Care Economics requirements and include additional education in business and contract negotiation, radiology sales and marketing, and governmental and private payers' influence in the practice of radiology. A health care economics curriculum for radiology residents incorporating three phases of education was developed and implemented. Phase 1 of the curriculum constituted basic education through didactic lectures covering System-Based Practice, SBP2: Health Care Economics requirements. Phase 2 constituted further, more advanced didactic lectures on radiology sales and marketing techniques as well as government and private insurers' role in the business of radiology. Phase 3 applied knowledge attained from the initial two phases to real-life case scenario exercises and radiology department business miniretreats with the remainder of the radiology department. A health care economics skills curriculum in radiology residency is attainable and essential in the education of future radiology residents in the ever-changing climate of health care economics. Institution of more comprehensive programs will likely maximize the long-term success of radiology as a specialty by identifying and educating future leaders in the field of radiology. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. A practical description and student perspective of the integration of radiology into lower limb musculoskeletal anatomy.

    PubMed

    Davy, S; O'Keeffe, G W; Mahony, N; Phelan, N; Barry, D S

    2017-05-01

    Anatomy educators are increasing their utilisation of radiology in anatomy education in line with growing requirements for undergraduate radiology competency and clinical need. We aimed to evaluate student perceptions of radiology and to outline the technical and academic considerations underlying the integration of radiology into musculoskeletal practical anatomy sessions. The formal integration of radiology into anatomy practical sessions took place over a 5-week period during the lower limb musculoskeletal component of the anatomy course taught to first-year medical students. During practical sessions, students were required to rotate between aligned audio-visual radiology presentations, osteology/anatomical models, and prosection/dissection learning stations. After completing the course, students were invited to complete a survey to establish their opinions on radiology as a mode of learning and their satisfaction with radiological integration in anatomical practical sessions. Most students were not familiar with radiology prior to attending our university. All our students agreed or strongly agreed that learning to read radiographs in anatomy is important and most agreed that radiology is a valid assessment tool. Sixty percent stated that radiology facilitated their understanding of anatomy. The majority believed that radiology was best suited to clinically relevant anatomy and X-rays were their preferred learning tool. The practical approach to integrating radiology into undergraduate musculoskeletal anatomy described here did not place strain on existing academic resources. Most students agreed that radiology should be increased in anatomy education and that learning to understand radiographs in anatomy was important for clinical practice.

  11. An autopsy study of combined pulmonary fibrosis and emphysema: correlations among clinical, radiological, and pathological features

    PubMed Central

    2014-01-01

    Background Clinical evaluation to differentiate the characteristic features of pulmonary fibrosis and emphysema is often difficult in patients with combined pulmonary fibrosis and emphysema (CPFE), but diagnosis of pulmonary fibrosis is important for evaluating treatment options and the risk of acute exacerbation of interstitial pneumonia of such patients. As far as we know, it is the first report describing a correlation among clinical, radiological, and whole-lung pathological features in an autopsy cases of CPFE patients. Methods Experts retrospectively reviewed the clinical charts and examined chest computed tomography (CT) images and pathological findings of an autopsy series of 22 CPFE patients, and compared these with findings from 8 idiopathic pulmonary fibrosis (IPF) patients and 17 emphysema-alone patients. Results All patients had a history of heavy smoking. Forced expiratory volume in 1 s/forced vital capacity (FEV1/FVC%) was significantly lower in the emphysema-alone group than the CPFE and IPF-alone groups. The percent predicted diffusing capacity of the lung for carbon monoxide (DLCO%) was significantly lower in the CPFE group than the IPF- and emphysema-alone groups. Usual interstitial pneumonia (UIP) pattern was observed radiologically in 15 (68.2%) CPFE and 8 (100%) IPF-alone patients and was pathologically observed in all patients from both groups. Pathologically thick-cystic lesions involving one or more acini with dense wall fibrosis and occasional fibroblastic foci surrounded by honeycombing and normal alveoli were confirmed by post-mortem observation as thick-walled cystic lesions (TWCLs). Emphysematous destruction and enlargement of membranous and respiratory bronchioles with fibrosis were observed in the TWCLs. The cystic lesions were always larger than the cysts of honeycombing. The prevalence of both radiological and pathological TWCLs was 72.7% among CPFE patients, but no such lesions were observed in patients with IPF or emphysema alone (p = 0.001). The extent of emphysema in CPFE patients with TWCLs was greater than that in patients without such lesions. Honeycombing with emphysema was also observed in 11 CPFE patients. Conclusions TWCLs were only observed in the CPFE patients. They were classified as lesions with coexistent fibrosing interstitial pneumonia and emphysema, and should be considered an important pathological and radiological feature of CPFE. PMID:24972672

  12. Serum albumin predicts survival in patients with hilar cholangiocarcinoma

    PubMed Central

    Waghray, Abhijeet; Sobotka, Anastasia; Marrero, Carlos Romero; Estfan, Bassam; Aucejo, Federico

    2017-01-01

    Background and aims: Hilar cholangiocarcinoma is a devastating malignancy with incidence varying by geography and other risk factors. Rapid progression of disease and delays in diagnosis restrict the number of patients eligible for curative therapy. The objective of this study was to determine prognostic factors of overall survival in all patients presenting with hilar cholangiocarcinoma. Methods: All adult patients with histologically confirmed hilar cholangiocarcinoma from 2003 to 2013 were evaluated for predictors of survival using demographic factors, laboratory data, symptoms and radiological characteristics at presentation. Results: A total of 116 patients were identified to have pathological diagnosis of hilar cholangiocarcinoma and were included in the analysis. Patients with a serum albumin level >3.0 g/dL (P < 0.01), cancer antigen 19‐9 ≤200 U/mL (P = 0.03), carcinoembryonic antigen ≤10 ìg/L (P < 0.01) or patients without a history of cirrhosis (P < 0.01) or diabetes (P = 0.02) were associated with a greater length of overall survival. A serum albumin level >3.0 g/dL was identified as an independent predictor of overall survival (hazard ratio 0.31; 95% confidence interval 0.14–0.70) with a survival benefit of 44 weeks. Conclusion: This study was the largest analysis to date of prognostic factors in patients with hilar cholangiocarcinoma. A serum albumin level >3.0 g/dL conferred an independent survival advantage with a significantly greater length of survival. PMID:27389416

  13. Radiological controls integrated into design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kindred, G.W.

    1995-03-01

    Radiological controls are required by law in the design of commercial nuclear power reactor facilities. These controls can be relatively minor or significant, relative to cost. To ensure that radiological controls are designed into a project, the health physicist (radiological engineer) must be involved from the beginning. This is especially true regarding keeping costs down. For every radiological engineer at a nuclear power plant there must be fifty engineers of other disciplines. The radiological engineer cannot be an expert on every discipline of engineering. However, he must be knowledgeable to the degree of how a design will impact the facilitymore » from a radiological perspective. This paper will address how to effectively perform radiological analyses with the goal of radiological controls integrated into the design package.« less

  14. Optically stimulated luminescence dosimetry with gypsum wallboard (drywall).

    PubMed

    Thompson, Jeroen W; Burdette, Kevin E; Inrig, Elizabeth L; Dewitt, Regina; Mistry, Rajesh; Rink, W Jack; Boreham, Douglas R

    2010-09-01

    Gypsum wallboard (drywall) represents an attractive target for retrospective dosimetry by optically stimulated luminescence (OSL) in the event of a radiological accident or malicious use of nuclear material. In this study, wallboard is shown to display a radiation-induced luminescence signal (RIS) as well as a natural background signal (NS), which is comparable in intensity to the RIS. Excitation and emission spectra show that maximum luminescence intensity is obtained for stimulation with blue light-emitting diodes (470 nm) and for detection in the ultraviolet region (290-370 nm). It is necessary to decrease the optical stimulation power dramatically in order to adequately separate the RIS from the interfering background signal. The necessary protocols are developed for accurately measuring the absorbed dose as low as 500 mGy and demonstrate that the RIS decays logarithmically with storage time, with complete erasure expected within 1-4 d.

  15. The error analysis of Lobular and segmental division of right liver by volume measurement.

    PubMed

    Zhang, Jianfei; Lin, Weigang; Chi, Yanyan; Zheng, Nan; Xu, Qiang; Zhang, Guowei; Yu, Shengbo; Li, Chan; Wang, Bin; Sui, Hongjin

    2017-07-01

    The aim of this study is to explore the inconsistencies between right liver volume as measured by imaging and the actual anatomical appearance of the right lobe. Five healthy donated livers were studied. The liver slices were obtained with hepatic segments multicolor-infused through the portal vein. In the slices, the lobes were divided by two methods: radiological landmarks and real anatomical boundaries. The areas of the right anterior lobe (RAL) and right posterior lobe (RPL) on each slice were measured using Photoshop CS5 and AutoCAD, and the volumes of the two lobes were calculated. There was no statistically significant difference between the volumes of the RAL or RPL as measured by the radiological landmarks (RL) and anatomical boundaries (AB) methods. However, the curves of the square error value of the RAL and RPL measured using CT showed that the three lowest points were at the cranial, intermediate, and caudal levels. The U- or V-shaped curves of the square error rate of the RAL and RPL revealed that the lowest value is at the intermediate level and the highest at the cranial and caudal levels. On CT images, less accurate landmarks were used to divide the RAL and RPL at the cranial and caudal layers. The measured volumes of hepatic segments VIII and VI would be less than their true values, and the measured volumes of hepatic segments VII and V would be greater than their true values, according to radiological landmarks. Clin. Anat. 30:585-590, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. Soil radioactivity levels, radiological maps and risk assessment for the state of Kuwait.

    PubMed

    Alazemi, N; Bajoga, A D; Bradley, D A; Regan, P H; Shams, H

    2016-07-01

    An evaluation of the radioactivity levels associated with naturally occurring radioactive materials has been undertaken as part of a systematic study to provide a surface radiological map of the State of Kuwait. Soil samples from across Kuwait were collected, measured and analysed in the current work. These evaluations provided soil activity concentration levels for primordial radionuclides, specifically members of the (238)U and (232)Th decay chains and (40)K which. The (238)U and (232)Th chain radionuclides and (40)K activity concentration values ranged between 5.9 ↔ 32.3, 3.5 ↔ 27.3, and 74 ↔ 698 Bq/kg respectively. The evaluated average specific activity concentrations of (238)U, (232)Th and (40)K across all of the soil samples have mean values of 18, 15 and 385 Bq/kg respectively, all falling below the worldwide mean values of 35, 40 and 400 Bq/kg respectively. The radiological risk factors are associated with a mean of 33.16 ± 2.46 nG/h and 68.5 ± 5.09 Bq/kg for the external dose rate and Radium equivalent respectively. The measured annual dose rates for all samples gives rise to a mean value of 40.8 ± 3.0 μSv/y while the internal and internal hazard indices have been found to be 0.23 ± 0.02 and 0.19 ± 0.01 respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. DICOM image integration into an electronic medical record using thin viewing clients

    NASA Astrophysics Data System (ADS)

    Stewart, Brent K.; Langer, Steven G.; Taira, Ricky K.

    1998-07-01

    Purpose -- To integrate radiological DICOM images into our currently existing web-browsable Electronic Medical Record (MINDscape). Over the last five years the University of Washington has created a clinical data repository combining in a distributed relational database information from multiple departmental databases (MIND). A text-based view of this data called the Mini Medical Record (MMR) has been available for three years. MINDscape, unlike the text based MMR, provides a platform independent, web browser view of the MIND dataset that can easily be linked to other information resources on the network. We have now added the integration of radiological images into MINDscape through a DICOM webserver. Methods/New Work -- we have integrated a commercial webserver that acts as a DICOM Storage Class Provider to our, computed radiography (CR), computed tomography (CT), digital fluoroscopy (DF), magnetic resonance (MR) and ultrasound (US) scanning devices. These images can be accessed through CGI queries or by linking the image server database using ODBC or SQL gateways. This allows the use of dynamic HTML links to the images on the DICOM webserver from MINDscape, so that the radiology reports already resident in the MIND repository can be married with the associated images through the unique examination accession number generated by our Radiology Information System (RIS). The web browser plug-in used provides a wavelet decompression engine (up to 16-bits per pixel) and performs the following image manipulation functions: window/level, flip, invert, sort, rotate, zoom, cine-loop and save as JPEG. Results -- Radiological DICOM image sets (CR, CT, MR and US) are displayed with associated exam reports for referring physician and clinicians anywhere within the widespread academic medical center on PCs, Macs, X-terminals and Unix computers. This system is also being used for home teleradiology application. Conclusion -- Radiological DICOM images can be made available medical center wide to physicians quickly using low-cost and ubiquitous, thin client browsing technology and wavelet compression.

  18. Integrating Radiology and Anatomy Teaching in Medical Education in the UK--The Evidence, Current Trends, and Future Scope.

    PubMed

    Heptonstall, N B; Ali, T; Mankad, K

    2016-04-01

    This review article presents the current evidence of the importance of integrating radiology and anatomy in medical education in the UK, a recommendation by a number of key anatomy, education, and radiology organizations. Current evidence highlights that on average only 5% of total teaching time in medical education is dedicated to radiology. Often, radiology teaching does not adequately fulfill students' learning needs and potentially leaves them underprepared for medical practice. Benefits of integrating radiology and anatomy include improved clinical application of anatomy, an increase in student's interest in anatomy, and ultimately improved radiological interpretation. Various modalities exist for the integration of radiology and anatomy, facilitated by the vast portability of radiological images. It appears that combining radiological resources with traditional anatomy teaching methodology in a blended approach is most beneficial. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  19. Annual environmental monitoring report of the Lawrence Berkeley Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schleimer, G.E.

    1989-06-01

    The Environmental Monitoring Program of the Lawrence Berkeley Laboratory (LBL) is described. Data for 1988 are presented and general trends are discussed. In order to establish whether LBL research activities produced any impact on the population surrounding the laboratory, a program of environmental air and water sampling and continuous radiation monitoring was carried on throughout the year. For 1988, as in the previous several years, dose equivalents attributable to LBL radiological operations were a small fraction of both the relevant radiation protection guidelines (RPG) and of the natural radiation background. 16 refs., 7 figs., 21 tabs.

  20. Multimodality cardiac imaging at IRCCS Policlinico San Donato: a new interdisciplinary vision.

    PubMed

    Lombardi, Massimo; Secchi, Francesco; Pluchinotta, Francesca R; Castelvecchio, Serenella; Montericcio, Vincenzo; Camporeale, Antonia; Bandera, Francesco

    2016-04-28

    Multimodality imaging is the efficient integration of various methods of cardiovascular imaging to improve the ability to diagnose, guide therapy, or predict outcome. This approach implies both the availability of different technologies in a single unit and the presence of dedicated staff with cardiologic and radiologic background and certified competence in more than one imaging technique. Interaction with clinical practice and existence of research programmes and educational activities are pivotal for the success of this model. The aim of this paper is to describe the multimodality cardiac imaging programme recently started at San Donato Hospital.

Top