Cova, Maria Assunta; Stacul, Fulvio; Quaranta, Roberto; Guastalla, Pierpaolo; Salvatori, Guglielmo; Banderali, Giuseppe; Fonda, Claudio; David, Vincenzo; Gregori, Massimo; Zuppa, Antonio Alberto; Davanzo, Riccardo
2014-08-01
Breastfeeding is a well-recognised investment in the health of the mother-infant dyad. Nevertheless, many professionals still advise breastfeeding mothers to temporarily discontinue breastfeeding after contrast media imaging. Therefore, we performed this review to provide health professionals with basic knowledge and skills for appropriate use of contrast media. A joint working group of the Italian Society of Radiology (SIRM), Italian Society of Paediatrics (SIP), Italian Society of Neonatology (SIN) and Task Force on Breastfeeding, Ministry of Health, Italy prepared a review of the relevant medical literature on the safety profile of contrast media for the nursing infant/child. Breastfeeding is safe for the nursing infant of any post-conceptional age after administration of the majority of radiological contrast media to the mother; only gadolinium-based agents considered at high risk of nephrogenic systemic fibrosis (gadopentetate dimeglumine, gadodiamide, gadoversetamide) should be avoided in the breastfeeding woman as a precaution; there is no need to temporarily discontinue breastfeeding or to express and discard breast milk following the administration of contrast media assessed as compatible with breastfeeding. Breastfeeding women should receive unambiguous professional advice and clear encouragement to continue breastfeeding after imaging with the compatible contrast media. • Breastfeeding is a well-known investment in the health of the mother-infant dyad. • Breastfeeding is safe after administration of contrast media to the mother. • There is no need to temporarily discontinue breastfeeding following administration of contrast media.
Callahan, Michael J; Servaes, Sabah; Lee, Edward Y; Towbin, Alexander J; Westra, Sjirk J; Frush, Donald P
2014-04-01
There are limited data available on the use of i.v. contrast media for CT studies in the pediatric population. The purpose of this study is to determine the practice patterns of i.v. contrast media usage for pediatric CT by members of the Society for Pediatric Radiology (SPR). SPR members were surveyed regarding the use of i.v. contrast media for pediatric CT studies. Questions pertained to information required before administering i.v. contrast media, types of central catheters for injecting i.v. contrast media, injection rates based on angiocatheter size and study type, and management of i.v. contrast media extravasation. The response rate of 6% (88/1545) represented practice patterns of 26% (401/1545) of the SPR membership. Most respondents thought the following clinical information was mandatory before i.v. contrast media administration: allergy to i.v. contrast media (97%), renal insufficiency (97%), current metformin use (72%), significant allergies (61%), diabetes (54%), and asthma (52%). Most administered i.v. contrast media through nonimplanted central venous catheters (78%), implanted venous ports (78%), and peripherally inserted central catheters (72%). The most common maximum i.v. contrast media injection rates were 5.0 mL/s or greater for a 16-gauge angiocatheter, 4.0 mL/s for an 18-gauge angiocatheter, 3.0 mL/s for a 20-gauge angiocatheter, and 2.0 mL/s for a 22-gauge angiocatheter. For soft-tissue extravasation of i.v. contrast media, 95% elevate the affected extremity, 76% use ice, and 45% use heat. The results of this survey illustrate the collective opinion of a subset of SPR members relating to the use of i.v. contrast media in pediatric CT, providing guidelines for clinical histories needed before i.v. contrast media, maximum i.v. contrast injection rates for standard angiocatheters, contrast media injection rates for specific CT studies, and management of i.v. contrast media soft-tissue extravasation.
Adverse Effects of Iodine-derived Intravenous Radiopaque Contrast Media.
Matthews, Eric P
2015-01-01
Although the advent of nonionic low-osmolar contrast agents has reduced the probability of a reaction to radiopaque contrast media derived from tri-iodinated benzoic acid, reactions still occur. Radiologic technologists must understand and know how to manage adverse effects of contrast media. Prompt attention to patients who exhibit the early signs of an adverse reaction can help to ensure the reaction does not progress to become severe or life-threatening.
76 FR 25357 - Advisory Committee; Medical Imaging Drugs Advisory Committee; Reestablishment
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-04
... and contrast media used in diagnostic radiology and makes appropriate recommendations to the... authorities knowledgeable in the fields of nuclear medicine, radiology, epidemiology or statistics, and...
Contrast medium extravasation injury: guidelines for prevention and management.
Bellin, Marie-France; Jakobsen, Jarl A; Tomassin, Isabelle; Thomsen, Henrik S; Morcos, Sameh K; Thomsen, H S; Morcos, S K; Almén, T; Aspelin, P; Bellin, M F; Clauss, W; Flaten, H; Grenier, N; Ideé, J-M; Jakobsen, J A; Krestin, G P; Stacul, F; Webb, J A W
2002-11-01
Extravasation of contrast material is a well-recognized complication of contrast-enhanced imaging studies. The management of this complication is contentious; therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and issue guidelines. A comprehensive literature search was carried out. The resulting report was discussed at the 8th European Symposium on Urogenital Radiology in Genoa, Italy. Automated power injection may result in extravasation of large volumes and may or can lead to severe tissue damage. Infants, young children and unconscious and debilitated patients are particularly at risk of extravasation during contrast media injection. Fortunately, most extravasations result in minimal swelling or erythema, with no long-term sequelae; however, severe skin necrosis and ulceration may occur. Large volumes of high osmolar contrast media are known to induce significant tissue damage. Compartment syndrome may be seen associated with extravasation of large volumes. Conservative management is often adequate, but in serious cases the advice of a plastic surgeon is recommended. Based on the review simple guidelines for prophylaxis and management of contrast medium extravasation injuries are proposed.
Frenzel, Thomas; Lawaczeck, Rüdiger; Taupitz, Matthias; Jost, Gregor; Lohrke, Jessica; Sieber, Martin A; Pietsch, Hubertus
2015-09-01
Over the last 120 years, the extensive advances in medical imaging allowed enhanced diagnosis and therapy of many diseases and thereby improved the quality of life of many patient generations. From the beginning, all technical solutions and imaging procedures were combined with dedicated pharmaceutical developments of contrast media, to further enhance the visualization of morphology and physiology. This symbiosis of imaging hardware and contrast media development was of high importance for the development of modern clinical radiology. Today, all available clinically approved contrast media fulfill the highest requirements for clinical safety and efficacy. All new concepts to increase the efficacy of contrast media have also to consider the high clinical safety standards and cost of goods of current marketed contrast media. Nevertheless, diagnostic imaging will contribute significantly to the progresses in medicine, and new contrast media developments are mandatory to address the medical needs of the future.
MRI and CT contrast media extravasation: A systematic review.
Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H; Prince, Martin R
2018-03-01
This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT.
Della-Torre, E; Berti, A; Yacoub, M R; Guglielmi, B; Tombetti, E; Sabbadini, M G; Voltolini, S; Colombo, G
2015-05-01
The purpose of the present work is to evaluate the efficacy of an approach that combines clinical history, skin tests results, and premedication, in preventing recurrent hypersensitivity reactions to iodinated contrast media (ICM). Skin Prick tests, Intradermal tests, and Patch tests were performed in 36 patients with a previous reaction to ICM. All patients underwent a second contrast enhanced radiological procedure with an alternative ICM selected on the basis of the proposed approach. After alternative ICM re-injection, only one patient presented a mild NIR. The proposed algorithm, validated in clinical settings where repeated radiological exams are needed, offers a safe and practical approach for protecting patients from recurrent hypersensitivity reactions to ICM.
Renal-related adverse effects of intravenous contrast media in computed tomography
Leow, Kheng Song; Wu, Yi Wei; Tan, Cher Heng
2015-01-01
Renal-related adverse effects of intravascular contrast media (CM) include contrast-induced nephropathy in computed tomography and angiography. While large retrospective studies have been published, the exact pathogenesis of this condition is still unknown. We review the main international guidelines, including the American College of Radiology white paper and the guidelines of European Society of Urogenital Radiology, Royal College of Radiologists and Canadian Association of Radiologists, as well as their references, regarding this subject. We present a simplified, concise approach to renal-related adverse effects of CM, taking into consideration the basis for each recommendation in these published guidelines. This will allow the reader to better understand the rationale behind appropriate patient preparation for cross-sectional imaging. PMID:25917468
MRI and CT contrast media extravasation
Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H.; Prince, Martin R.
2018-01-01
Abstract Background: This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Methods: Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Results: Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Conclusion: Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT. PMID:29489663
Nicola, Refky; Shaqdan, Khalid Wael; Aran, Shima; Prabhakar, Anand M; Singh, Ajay Kumar; Abujudeh, Hani H
2016-01-01
Intravenous contrast administration has been of great importance in diagnostic radiology, but it is not without risks either due to the local, systemic allergic reactions or due to subcutaneous extravasation of contrast media. Subcutaneous contrast medium extravasationis an infrequent, yet a well-recognized complication. However, most incidents are minor and can be managed conservatively, but there are a few cases that require immediate surgical intervention. This article discusses the risks factors, clinical manifestations, and conservative and surgical approaches of subcutaneous contrast media extravasation for both computed tomography and magnetic resonance imaging. Copyright © 2015 Mosby, Inc. All rights reserved.
Application of contrast media in post-mortem imaging (CT and MRI).
Grabherr, Silke; Grimm, Jochen; Baumann, Pia; Mangin, Patrice
2015-09-01
The application of contrast media in post-mortem radiology differs from clinical approaches in living patients. Post-mortem changes in the vascular system and the absence of blood flow lead to specific problems that have to be considered for the performance of post-mortem angiography. In addition, interpreting the images is challenging due to technique-related and post-mortem artefacts that have to be known and that are specific for each applied technique. Although the idea of injecting contrast media is old, classic methods are not simply transferable to modern radiological techniques in forensic medicine, as they are mostly dedicated to single-organ studies or applicable only shortly after death. With the introduction of modern imaging techniques, such as post-mortem computed tomography (PMCT) and post-mortem magnetic resonance (PMMR), to forensic death investigations, intensive research started to explore their advantages and limitations compared to conventional autopsy. PMCT has already become a routine investigation in several centres, and different techniques have been developed to better visualise the vascular system and organ parenchyma in PMCT. In contrast, the use of PMMR is still limited due to practical issues, and research is now starting in the field of PMMR angiography. This article gives an overview of the problems in post-mortem contrast media application, the various classic and modern techniques, and the issues to consider by using different media.
Endothelial safety of radiological contrast media: why being concerned.
Scoditti, Egeria; Massaro, Marika; Montinari, Maria Rosa
2013-01-01
Iodinated radiocontrast media have been the most widely used pharmaceuticals for intravascular administration in diagnostic and interventional angiographic procedures. Although they are regarded as relatively safe drugs and vascular biocompatibility of contrast media has been progressively improved, severe adverse reactions may occur, among which acute nephropathy is one of the most clinically significant complications after intravascular administration of contrast media and a powerful predictor of poor early and long-term outcomes. Since radiocontrast media are given through the arterial or the venous circulation in vascular procedures, morphological and functional changes of the microvascular and macrovascular endothelial cells substantially contribute to the pathogenesis of organ-specific and systemic adverse reactions of contrast media. Endothelial toxicity of contrast media seems to be the result of both direct proapoptotic effects and morphological derangements, as well as endothelial dysfunction and induction of inflammation, oxidative stress, thrombosis, and altered vasomotor balance, with predominant vasoconstrictive response in atherosclerotic coronary arteries and kidney microcirculation. Further understanding of pathogenetic mechanisms underlying contrast media-induced adverse reactions in cellular targets, including endothelial cells, will hopefully lead to the development of novel preventive strategies appropriately curbing the pathogenesis of contrast media vasotoxicity. Copyright © 2012 Elsevier Inc. All rights reserved.
Extravasation of radiographic contrast media: prevention, diagnosis, and treatment.
Tonolini, Massimo; Campari, Alessandro; Bianco, Roberto
2012-01-01
Contrast media extravasation represents a not unusual problem in radiological practice. Incidence, patient-, and procedure-related risk factors, pathogenesis, and clinical manifestations of extravasation injuries are discussed with a review of recent literature, and a practical preventive approach is proposed. A diagnostic and therapeutic protocol, to be applied whenever contrast extravasation is detected, includes radiographic assessment of compartmentalization, antidote application, local care, and clinical follow-up; indications for surgical consultation and adverse event reporting are provided. Copyright © 2012 Mosby, Inc. All rights reserved.
Sessa, Maurizio; Rossi, Claudia; Rafaniello, Concetta; Mascolo, Annamaria; Cimmaruta, Daniela; Scavone, Cristina; Fiorentino, Sonia; Grassi, Enrico; Reginelli, Alfonso; Rotondo, Antonio; Sportiello, Liberata
2016-12-01
The current study aims to assess the preventability of the contrast media adverse drug reactions reported through the Campania spontaneous reporting system, identifying the possible limitations emerged in this type of evaluation. All the individual case safety reports validated by the Campania Pharmacovigilance Regional Centre from July 2012 to September 2015 were screened to select those that reported contrast media as suspected drug. Campania Preventability Assessment Committee, in collaboration with clinicians specialized in Radiology, assessed the preventability according to the P-Method, through a case-by-case approach. From July 2012 to September 2015, 13798 cases were inserted by pharmacovigilance managers in the Italian Pharmacovigilance Network database (in the geographical contest of the Campania Region), of which 67 reported contrast media as suspected drug. Five preventable cases were found. The most reported causes for preventability were the inappropriate drug use for the case clinical conditions and the absence of the preventive measure administrated prior to the contrast media administration. Several limitations were found in the evaluation of the critical criteria for the preventability assessment. Educational initiatives will be organized directly to the healthcare professionals involved in the contrast media administration, to promote an appropriate use of the contrast media.
Contrast induced nephropathy: updated ESUR Contrast Media Safety Committee guidelines.
Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter; Webb, Judith A W; Thomsen, Henrik S; Morcos, Sameh K; Almén, Torsten; Aspelin, Peter; Bellin, Marie-France; Clement, Olivier; Heinz-Peer, Gertraud
2011-12-01
The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic measures used to reduce the incidence of CIN, and the management of patients receiving metformin. Key Points • Definition, risk factors and prevention of contrast medium induced nephropathy are reviewed. • CIN risk is lower with intravenous than intra-arterial iodinated contrast medium. • eGFR of 45 ml/min/1.73 m (2) is CIN risk threshold for intravenous contrast medium. • Hydration with either saline or sodium bicarbonate reduces CIN incidence. • Patients with eGFR ≥ 60 ml/min/1.73 m (2) receiving contrast medium can continue metformin normally.
Bid purchasing of radiopharmaceuticals and radiopaque contrast media
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swanson, D.P.; Jakubowski, D.L.; Shoup, L.K.
Use of product standardization and competitive-bid purchasing for radiopharmaceuticals and radiopaque contrast media in a 1000-bed teaching hospital is described. The hospital's use of radiopharmaceuticals was reviewed, and all agents were listed with their product specifications and order quantity or frequency. Manufacturers and wholesalers were asked to submit unit prices for each of their products. Similar procedures were followed for radiopaque contrast media; wholesalers and manufacturers were asked to submit unit prices that would be guaranteed for a 12-month contract period. A nuclear pharmacist and radiologists reviewed the submitted bids and awarded contracts, basing their decisions primarily on product acceptabilitymore » and selection criteria and then on relative costs of the agents. Annual costs were reduced 16% ($16,500) for radiopharmaceuticals and 21.3% ($66,500) for radiopaque contrast media. The program also resulted in decreased inventory of radiopaque contrast media and in faster and less expensive acquisition of emergency orders. Working with the radiology department to compile a standard list of radiopharmaceuticals and radiopaque contrast media and soliciting competitive bids by vendors of these products resulted in annual savings of more than $83,000.« less
Sakellariou, Sophia; Li, Wenguang; Paul, Manosh C; Roditi, Giles
2016-12-01
Iodinated contrast media (CM) are the most commonly used injectables in radiology today. A range of different media are commercially available, combining various physical and chemical characteristics (ionic state, osmolality, viscosity) and thus exhibiting distinct in vivo behaviour and safety profiles. In this paper, numerical simulations of blood flow with contrast media were conducted to investigate the effects of contrast viscosity on generated vessel wall shear stress and vessel wall pressure to elucidate any possible relation to extravasations. Five different types of contrast for Iodine fluxes ranging at 1.5-2.2gI/s were modelled through 18G and 20G cannulae placed in an ideal vein at two different orientation angles. Results demonstrate that the least viscous contrast media generate the least maximum wall shear stress as well as the lowest total pressure for the same flow rate. This supports the empirical clinical observations and hypothesis that more viscous contrast media are responsible for a higher percentage of contrast extravasations. In addition, results support the clinical hypothesis that a catheter tip directed obliquely to the vein wall always produces the highest maximum wall shear stress and total pressure due to impingement of the contrast jet on the vessel wall. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Böhm, Ingrid; Nairz, Knud; Morelli, John N; Keller, Patricia Silva Hasembank; Heverhagen, Johannes T
2017-04-01
Purpose To test the hypothesis that the incomplete diagnosis "iodine allergy" is a possibly dangerous concept for patients under routine radiologic conditions. Materials and Methods 300 patients with a history of an "iodine allergy" were retrospectively screened and compared with two age-, sex-, and procedure-matched groups of patients either diagnosed with a nonspecific "iodine contrast medium (ICM) allergy" or an allergy to a specific ICM agent. For all groups, the clinical symptoms of the most recent past adverse drug reaction (ADR), prophylactic actions taken for subsequent imaging, and ultimate outcome were recorded and analyzed. Results The diagnosis "iodine allergy" was not otherwise specified in 84.3 % patients. For this group, in most cases, the symptoms of the previous ADRs were not documented. In contrast, the type of ADR was undocumented in only a minority of patients in the comparison groups. In the group of patients with an "iodine allergy" the percentage of unenhanced CT scans was greater than within the other two groups (36.7 % vs. 28.7 %/18.6 %). ADRs following prophylactic measures were only observed in the "iodine allergy" group (OR of 9.24 95 % CI 1.16 - 73.45; p < 0.04). Conclusion This data confirms the hypothesis that the diagnosis "iodine allergy" is potentially dangerous and results in uncertainty in clinical management and sometimes even ineffective prophylactic measures. Key points · The term "iodine allergy" is imprecise, because it designates allergies against different substance classes, such as disinfectants with complexed iodine and contrast media containing covalently bound iodine.. · There is a clear correlation between the exactness of the diagnosis - from the alleged "iodine allergy" to "contrast media allergy" to naming the exact culprit CM - and the quality of documentation of the symptoms.. · Management of patients diagnosed with "iodine allergy" was associated with uncertainty leading to unenhanced scans and sometimes unnecessary prophylactic actions.. · The term "iodine allergy" should be omitted, because it is potentially dangerous and can decrease the quality of radiology exams.. Citation Format · Böhm Ingrid, Nairz Knud, Morelli John N et al. Iodinated Contrast Media and the Alleged "Iodine Allergy": An Inexact Diagnosis Leading to Inferior Radiologic Management and Adverse Drug Reactions. Fortschr Röntgenstr 2017; 189: 326 - 332. © Georg Thieme Verlag KG Stuttgart · New York.
Risk Predictors for Postcontrast Acute Kidney Injury.
Krause, Trudy Millard; Ukhanova, Maria; Lee Revere, Frances; Finkel, Kevin W
2018-05-22
To evaluate risk predictors of acute kidney injury (AKI) after contrast-media procedures in a broader cohort of patients than previously reported. Comprehensive medical and pharmacy commercial claims data from 2012 to 2014. Claims associated with contrast-media procedures for 2,737,020 persons between January 1, 2012 and November 30, 2014, were reviewed. The overall incidence of AKI after a contrast-media procedure was 0.85%. AKI occurred in 26% of cases that had two or more contrast procedures within 30 days, compared with 9% of non-AKI cases. Although the incidence of postcontrast AKI was low, 10% of patients who developed AKI had a recent previous episode of AKI. In cases when AKI had occurred within 180 days of contrast administration, the odds of subsequent kidney injury was 9.39. Overall, there is a low risk (0.85%) of developing an AKI after a procedure with contrast-media consistent with several recent studies. However, in adults with a recent history of AKI, physicians must consider this history as a risk factor for subsequent AKI. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Contrast Media Extravasation in CT and MRI - A Literature Review and Strategies for Therapy.
Mandlik, Veronika; Prantl, Lukas; Schreyer, Andreas G
2018-06-18
Contrast extravasation events in daily radiological routine may lead to serious complications, especially during CT examinations. The resulting symptoms may vary from local pain up to skin ulcers, necrosis or even acute compartment syndrome.There are no uniformly accepted radiological guidelines or recommendations regarding detection and treatment of extravasation events and immanent complications in a timely manner. Systematic literature research considering the last 35 years via PubMed using search terms "contrast medium extravasation/paravasation". In the literature, there are conservative management approaches of contrast media extravasation without major evidence base, such as unguent dressings, cooling or splinting. This therapy is mostly symptomatic. Additionally, various invasive techniques are described. We discuss these techniques in the context of contemporary literature, such as the hyaluronidase Injection into the site of extravasation, suction/aspiration technique including flushing of the affected tissue areas and the squeezing technique. However, most citations lack scientific evidence: many articles include anecdotal enumerations, case studies or cite publications from the era, when ionic high osmolar contrast media was state-of-the-art. Besides, many authors derive their extravasation management from studies, where agents other than contrast media were investigated. After detailed literature review, we suggest early (plastic) surgical consultation when non-ionic, low-osmolar contrast medium extravasation is about 150 cc or more. In case of extravasation less than 150 cc but in presence of additional symptoms such as impaired perfusion or altered sensibility, the (plastic) surgeon should also be consulted instantly. We do not recommend any invasive first line therapy when contrast media extravasation is less than 150 cc and the patient presents no additional symptoms, besides swelling and local pain. Nevertheless continuous monitoring and accurate conservative management such as active cooling and elevation, splinting of the affected extremity are mandatory as early detection of critical symptoms helps to initiate prompt surgical intervention and avoid sequelae. · Morbidity after contrast media extravasation is extremely rare.. · Predicting sequelae after contrast extravasation is difficult at first sight.. · Treatments such as hyaluronidase injection, suction/aspiration, squeeze technique have been described.. · Surgical consultation is recommended for extravasation > 150 cc or when additional symptoms occur.. · Mandlik V, Prantl L, Schreyer AG. Contrast Media Extravasation in CT and MRI - A Literature Review and Strategies for Therapy. Fortschr Röntgenstr 2018; DOI: 10.1055/a-0628-7095. © Georg Thieme Verlag KG Stuttgart · New York.
Golder, W
2012-02-01
The synchronous use of chemically different contrast media in the same body compartment is a challenge for the radiologist, whether it is scheduled or unexpected. However, to inject contrast media containing iodine and gadolinium at the same time can be a prerequisite for the examination of several organs or organ systems. Unlike other topics of contrast-enhanced imaging procedures, the difficulties encountered with double contrast injections have been widely ignored in the literature. In the absence of reliable data from experimental and clinical studies the radiologist is dependent on case reports, information provided by the contrast media manufacturers, personal communications, mostly scanty personal experiences and a skilful time management, in order to overcome the situation. Only the combination of X-ray, computed tomography and magnetic resonance arthrography can be performed without another thought. However, the more or less synchronous vascular application of contrast media containing iodine and gadolinium requires vigilance. The more seriously ill the patient is, the more caution is advised even if the decision on the combined administration has to be reached urgently. The following overview gives a description of the properties of contrast media containing iodine and gadolinium as far as interactions following simultaneous administration are concerned. Subsequently, the clinically relevant situations and constellations are outlined and analyzed.
A Review: Radiographic Iodinated Contrast Media-Induced Thyroid Dysfunction
Leung, Angela M.; Braverman, Lewis E.; Brent, Gregory A.; Pearce, Elizabeth N.
2015-01-01
Context: Thyroid hormone production is dependent on adequate iodine intake. Excess iodine is generally well-tolerated, but thyroid dysfunction can occur in susceptible individuals after excess iodine exposure. Radiological iodinated contrast media represent an increasingly common source of excess iodine. Objective: This review will discuss the thyroidal response after acute exposure to excess iodine; contrast iodine-induced thyroid dysfunction; risks of iodine-induced thyroid dysfunction in vulnerable populations, such as the fetus, neonate, and patients with impaired renal function; and recommendations for the assessment and treatment of contrast iodine-induced thyroid dysfunction. Methods: Data for this review were identified by searching PubMed, Google Scholar, and references from relevant articles from 1948 to 2014. Conclusions: With the increase in the use of computed tomography scans in the United States, there is increasing risk of contrast-induced thyroid dysfunction. Patients at risk of developing iodine-induced thyroid dysfunction should be closely monitored after receiving iodinated contrast media and should be treated as needed. PMID:25375985
Jingu, Akiko; Fukuda, Junya; Taketomi-Takahashi, Ayako; Tsushima, Yoshito
2014-10-06
Adverse reactions to iodinated and gadolinium contrast media are an important clinical issue. Although some guidelines have proposed oral steroid premedication protocols to prevent adverse reactions, some patients may have reactions to contrast media in spite of premedication (breakthrough reaction; BTR).The purpose of this study was to assess the frequency, type and severity of BTR when following an oral steroid premedication protocol. All iodinated and gadolinium contrast-enhanced radiologic examinations between August 2011 and February 2013 for which the premedication protocol was applied in our institution were assessed for BTRs. The protocol was applied to a total of 252 examinations (153 patients, ages 15-87 years; 63 males, 90 females). Of these, 152 were for prior acute adverse reactions to contrast media, 85 were for a history of bronchial asthma, and 15 were for other reasons. There were 198 contrast enhanced CTs and 54 contrast enhanced MRIs. There were nine BTR (4.5%) for iodinated contrast media, and only one BTR (1.9%) for gadolinium contrast media: eight were mild and one was moderate. No patient who had a mild index reaction (IR) had a severe BTR. Incidence of BTRs when following the premedication protocol was low. This study by no means proves the efficacy of premedication, but provides some support for following a premedication protocol to improve safety of contrast-enhanced examinations when prior adverse reactions are mild, or when there is a history of asthma.
2014-01-01
Background Adverse reactions to iodinated and gadolinium contrast media are an important clinical issue. Although some guidelines have proposed oral steroid premedication protocols to prevent adverse reactions, some patients may have reactions to contrast media in spite of premedication (breakthrough reaction; BTR). The purpose of this study was to assess the frequency, type and severity of BTR when following an oral steroid premedication protocol. Methods All iodinated and gadolinium contrast-enhanced radiologic examinations between August 2011 and February 2013 for which the premedication protocol was applied in our institution were assessed for BTRs. Results The protocol was applied to a total of 252 examinations (153 patients, ages 15–87 years; 63 males, 90 females). Of these, 152 were for prior acute adverse reactions to contrast media, 85 were for a history of bronchial asthma, and 15 were for other reasons. There were 198 contrast enhanced CTs and 54 contrast enhanced MRIs. There were nine BTR (4.5%) for iodinated contrast media, and only one BTR (1.9%) for gadolinium contrast media: eight were mild and one was moderate. No patient who had a mild index reaction (IR) had a severe BTR. Conclusion Incidence of BTRs when following the premedication protocol was low. This study by no means proves the efficacy of premedication, but provides some support for following a premedication protocol to improve safety of contrast-enhanced examinations when prior adverse reactions are mild, or when there is a history of asthma. PMID:25287952
Safe Use of Contrast Media: What the Radiologist Needs to Know.
Beckett, Katrina R; Moriarity, Andrew K; Langer, Jessica M
2015-10-01
Iodinated and gadolinium-based contrast media are used on a daily basis in most radiology practices. These agents often are essential to providing accurate diagnoses, and are nearly always safe and effective when administered correctly. However, reactions to contrast media do occur and can be life threatening. Therefore, it is critical for faculty and staff to know how reactions to contrast agents manifest and how to treat them promptly. The decline in renal function seen occasionally after intravenous administration of iodinated contrast agents is poorly understood and likely multifactorial, and its association with the contrast medium may be overemphasized. However, it is important that radiologists be aware of current understanding and strategies to decrease the incidence of renal dysfunction. Nephrogenic systemic fibrosis, a skin disease, is an adverse reaction related to use of some gadolinium-based contrast agents in patients with chronic renal failure. The types of gadolinium most often associated with this condition and the indications for withholding gadolinium are important and are discussed in this article. The use of enteric contrast agents and contrast agents during pregnancy and nursing are reviewed briefly. Current knowledge for safe use of contrast media and key concepts that all radiologists should know are summarized in this review. © RSNA, 2015.
Iodinated contrast media can induce long-lasting oxidative stress in hemodialysis patients.
Hwang, Seun Deuk; Kim, Yoon Ji; Lee, Sang Heun; Cho, Deok Kyu; Cho, Yun Hyeong; Moon, Sung Jin; Lee, Sang Choel; Yoon, Soo Young
2013-11-01
Due to their comorbidities, dialysis patients have many chances to undergo radiologic procedures using iodinated contrast media. We aimed to assess time-sequenced blood oxidative stress level after contrast exposure in hemodialysis (HD) patients compared to those in the non-dialysis population. We included 21 anuric HD patients [HD-coronary angiography (CAG) group] and 23 persons with normal renal function (nonHD-CAG group) scheduled for CAG, and assessed 4 oxidative stress markers [advanced oxidation protein products (AOPP); catalase; 8-hydroxydeoxyguanosine; and malondialdehyde] before and after CAG, and subsequently up to 28 days. In the nonHD-CAG group, only AOPP increased immediately after CAG and returned to baseline within one day. However, in the HD-CAG group, all four oxidative stress markers were significantly increased starting one day after CAG, and remained elevated longer than those in the nonHD-CAG group. Especially, AOPP level remained elevated for a month after contrast exposure. Our study showed that iodinated contrast media induces severe and prolonged oxidative stress in HD patients.
Myths and misconceptions concerning contrast media-induced anaphylaxis: a narrative review.
Böhm, Ingrid; Morelli, John; Nairz, Knud; Silva Hasembank Keller, Patricia; Heverhagen, Johannes T
2017-03-01
Contrast-enhanced radiological examinations are an increasingly important diagnostic tool in modern medicine. All approved and available contrast media (iodinated and gadolinium-based) are safe compounds that are well-tolerated by most patients. However, a small percentage of patients exhibit contrast medium-induced adverse drug reactions that are dose-dependent and predictable (type A) or an even smaller cohort experience so-called type B (dose-independent, non-predictable). To increase patients' safety, recommendations/guidelines have been put forth in the literature and advice passed down informally by radiologists in practice to ensure contrast media safety. Through these, both reasonable suggestions as well as misinterpretations and myths (such as the misleading terms "allergy-like" reactions, and "iodine-allergy", the wrong assumption that the initial contact to a contrast medium could not induce an allergy, the estimation that an anti-allergy premedication could suppress all possible adverse reactions, and interleukin-2 as a risk/trigger for contrast medium adverse events) have arisen. Since the latter are not only unhelpful but also potentially reduce patients' safety, such myths and misconceptions are the focus of this review.
Tsushima, Yoshito; Ishiguchi, Tsuneo; Murakami, Takamichi; Hayashi, Hiromitsu; Hayakawa, Katsumi; Fukuda, Kunihiko; Korogi, Yukunori; Sugimoto, Hideharu; Takehara, Yasuo; Narumi, Yoshifumi; Arai, Yasuaki; Kuwatsuru, Ryohei; Yoshimitsu, Kengo; Awai, Kazuo; Kanematsu, Masayuki; Takagi, Ryo
2016-02-01
To help establish consensus on the safe use of contrast media in Japan. Questionnaires were sent to accredited teaching hospitals with radiology residency programs. The reply rate was 45.4% (329/724). For contrast-induced nephropathy (CIN), chronic and acute kidney diseases were considered a risk factor in 96.7 and 93.6%, respectively, and dehydration in 73.9%. As preventive actions, intravenous hydration (89.1%) and reduction of iodinated contrast media dose (86.9%) were commonly performed. For nephrogenic systemic fibrosis (NSF), chronic and acute kidney diseases were considered risk factors in 98.5 and 90.6%, respectively, but use of unstable gadolinium-based contrast media was considered a risk factor in only 55.6%. A renal function test was always (63.5% in iodinated; 65.7% in gadolinium) or almost always (23.1; 19.8%) performed, and estimated glomerular filtration rate (eGFR) was the parameter most frequently used (80.8; 82.6%). For the patients with risk factors for acute adverse reaction (AAR), steroid premedication or/and change of contrast medium were frequent preventive actions, but intravenous steroid administration immediately before contrast media use was still performed. Our questionnaire survey revealed that preventive actions against CIN were properly performed based on patients' eGFR. Preventive actions against NSF and AAR still lacked consensus.
Li, X; Chen, J; Zhang, L; Liu, H; Wang, S; Chen, X; Fang, J; Wang, S; Zhang, W
2015-03-01
To analyse the pattern and factors that influence the incidence of adverse drug reactions (ADRs) induced by non-ionic iodinated contrast media and to evaluate their safety profiles. Data from 109,255 cases who underwent enhanced CT examination from 1 January 2008 to 31 August 2013 were analysed. ADRs were classified according to the criteria issued by the American College of Radiology and the Chinese Society of Radiology. A total of 375 (0.34%) patients had ADRs, including 281 mild (0.26%); 80 moderate (0.07%); and 14 severe (0.01%) ADRs; no death was found. 302 (80.53%) of the ADRs occurred within 15 min after examination. Patients aged 40-49 years (204 cases, 0.43%; p < 0.01) or who underwent coronary CT angiography (93 cases, 0.61%; p < 0.01) were at a higher risk of ADRs. Female patients (180 cases, 0.40%; p < 0.01) or outpatients had significantly higher incidence rates of ADRs. The symptoms and signs of most of the ADRs were resolved spontaneously within 24 h after appropriate treatment without sequelae. The occurrence of ADRs is caused by the combined effects of multiple factors. The ADRs induced by non-ionic iodinated contrast media are mainly mild ones, while moderate or severe ADRs are relatively rare, suggesting that enhanced CT examination with non-ionic iodinated contrast media is highly safe, and severe adverse events will seldom occur under appropriate care. The study included 109,255 patients enrolled in various types of enhanced CT examinations, which could reflect ADR conditions and regulations in Chinese population accurately and reliably.
Li, X; Chen, J; Zhang, L; Liu, H; Wang, S; Chen, X; Fang, J; Wang, S
2015-01-01
Objective: To analyse the pattern and factors that influence the incidence of adverse drug reactions (ADRs) induced by non-ionic iodinated contrast media and to evaluate their safety profiles. Methods: Data from 109,255 cases who underwent enhanced CT examination from 1 January 2008 to 31 August 2013 were analysed. ADRs were classified according to the criteria issued by the American College of Radiology and the Chinese Society of Radiology. Results: A total of 375 (0.34%) patients had ADRs, including 281 mild (0.26%); 80 moderate (0.07%); and 14 severe (0.01%) ADRs; no death was found. 302 (80.53%) of the ADRs occurred within 15 min after examination. Patients aged 40–49 years (204 cases, 0.43%; p < 0.01) or who underwent coronary CT angiography (93 cases, 0.61%; p < 0.01) were at a higher risk of ADRs. Female patients (180 cases, 0.40%; p < 0.01) or outpatients had significantly higher incidence rates of ADRs. The symptoms and signs of most of the ADRs were resolved spontaneously within 24 h after appropriate treatment without sequelae. Conclusion: The occurrence of ADRs is caused by the combined effects of multiple factors. The ADRs induced by non-ionic iodinated contrast media are mainly mild ones, while moderate or severe ADRs are relatively rare, suggesting that enhanced CT examination with non-ionic iodinated contrast media is highly safe, and severe adverse events will seldom occur under appropriate care. Advances in knowledge: The study included 109,255 patients enrolled in various types of enhanced CT examinations, which could reflect ADR conditions and regulations in Chinese population accurately and reliably. PMID:25582519
Fujiwara, Naoto; Tateishi, Ryosuke; Akahane, Masaaki; Taguri, Masataka; Minami, Tatsuya; Mikami, Shintaro; Sato, Masaya; Uchino, Koji; Uchino, Kouji; Enooku, Kenichiro; Kondo, Yuji; Asaoka, Yoshinari; Yamashiki, Noriyo; Goto, Tadashi; Shiina, Shuichiro; Yoshida, Haruhiko; Ohtomo, Kuni; Koike, Kazuhiko
2013-01-01
To elucidate whether repeated exposures to iodinated contrast media increase the risk of adverse reaction. We retrospectively reviewed 1,861 patients with hepatocellular carcinoma who visited authors' institution, a tertiary referral center, between 2004 and 2008. We analyzed cumulative probability of adverse reactions and risk factors. We categorized all symptoms into hypersensitivity reactions, physiologic reactions, and other reactions, according to the American College of Radiology guidelines, and evaluated each category as an event. We estimated the association between hazard for adverse reactions and the number of cumulative exposures to contrast media. We also evaluated subsequent contrast media injections and adverse reactions. There were 23,684 contrast media injections in 1,729 patients. One hundred and thirty-two patients were excluded because they were given no contrast media during the study period. Adverse reactions occurred in 196 (0.83%) patients. The cumulative incidence at 10(th), 20(th), and 30(th) examination was 7.9%, 15.2%, and 24.1%, respectively. Presence of renal impairment was found to be one of risk factors for adverse reactions. The estimated hazard of overall adverse reaction gradually decreased until around 10(th) exposure and rose with subsequent exposures. The estimated hazard of hypersensitivity showed V-shaped change with cumulative number of exposures. The estimated hazard of physiologic reaction had a tendency toward decreasing and that of other reaction had a tendency toward increasing. Second adverse reaction was more severe than the initial in only one among 130 patients receiving subsequent injections. Repeated exposures to iodinated contrast media increase the risk of adverse reaction.
Iodinated Contrast Media Can Induce Long-Lasting Oxidative Stress in Hemodialysis Patients
Hwang, Seun Deuk; Kim, Yoon Ji; Lee, Sang Heun; Cho, Deok Kyu; Cho, Yun Hyeong; Moon, Sung Jin; Lee, Sang Choel
2013-01-01
Purpose Due to their comorbidities, dialysis patients have many chances to undergo radiologic procedures using iodinated contrast media. We aimed to assess time-sequenced blood oxidative stress level after contrast exposure in hemodialysis (HD) patients compared to those in the non-dialysis population. Materials and Methods We included 21 anuric HD patients [HD-coronary angiography (CAG) group] and 23 persons with normal renal function (nonHD-CAG group) scheduled for CAG, and assessed 4 oxidative stress markers [advanced oxidation protein products (AOPP); catalase; 8-hydroxydeoxyguanosine; and malondialdehyde] before and after CAG, and subsequently up to 28 days. Results In the nonHD-CAG group, only AOPP increased immediately after CAG and returned to baseline within one day. However, in the HD-CAG group, all four oxidative stress markers were significantly increased starting one day after CAG, and remained elevated longer than those in the nonHD-CAG group. Especially, AOPP level remained elevated for a month after contrast exposure. Conclusion Our study showed that iodinated contrast media induces severe and prolonged oxidative stress in HD patients. PMID:24142649
Economic evaluation of intravenous iodinated contrast media in Italy.
Iannazzo, Sergio; Vandekerckhove, Stijn; De Francesco, Maria; Nayak, Akash; Ronco, Claudio; Morana, Giovanni; Valentino, Massimo
2014-01-01
Contrast-induced acute kidney injury (CI-AKI) is defined as a deterioration in renal function after administration of radiologic iodinated contrast media (CM). Iodixanol, showed a lower CI-AKI incidence than low-osmolar contrast media (LOCM). A cost-effectiveness analysis was performed comparing iodixanol and LOCM in intravenous (IV) setting in Italy. A Markov model was developed. Patients moved across four health states: CI-AKI free, CI-AKI, myocardial infarction, and death. The simulation horizon was lifetime with 1-month cycles. Costs and outcomes were discounted at 3.5 percent rate. CI-AKI incidence was considered from published literature across different definitions. Cost-effectiveness of iodixanol was assessed in terms of incremental cost per life-year gained. Net monetary benefit (NMB) was also calculated. Both deterministic and probabilistic sensitivity analyses were performed. Base-case results showed an average survival increase of 0.51 life-years and a savings of €7.25 for iodixanol versus LOCM. The cost-effectiveness of iodixanol was confirmed when other scenarios were explored, such as varying CI-AKI definition, sub-populations with specified risk factors, CM hospital bids prices, and inclusion of adverse drug reactions of allergic nature. An NMB ranging between €6,007.25 and €30,007.25 was calculated. Base-case results show that IV iodixanol is cost-effective compared with LOCM in the Italian clinical setting of a hospital computed tomography radiology practice. However, some caution is due, mainly linked to inherent limitations of the modeling technique and to the lack of agreement on CI-AKI incidence data in the clinical literature.
Fujiwara, Naoto; Tateishi, Ryosuke; Akahane, Masaaki; Taguri, Masataka; Minami, Tatsuya; Mikami, Shintaro; Sato, Masaya; Uchino, Kouji; Enooku, Kenichiro; Kondo, Yuji; Asaoka, Yoshinari; Yamashiki, Noriyo; Goto, Tadashi; Shiina, Shuichiro; Yoshida, Haruhiko; Ohtomo, Kuni; Koike, Kazuhiko
2013-01-01
Background To elucidate whether repeated exposures to iodinated contrast media increase the risk of adverse reaction. Materials and Methods We retrospectively reviewed 1,861 patients with hepatocellular carcinoma who visited authors’ institution, a tertiary referral center, between 2004 and 2008. We analyzed cumulative probability of adverse reactions and risk factors. We categorized all symptoms into hypersensitivity reactions, physiologic reactions, and other reactions, according to the American College of Radiology guidelines, and evaluated each category as an event. We estimated the association between hazard for adverse reactions and the number of cumulative exposures to contrast media. We also evaluated subsequent contrast media injections and adverse reactions. Results There were 23,684 contrast media injections in 1,729 patients. One hundred and thirty-two patients were excluded because they were given no contrast media during the study period. Adverse reactions occurred in 196 (0.83%) patients. The cumulative incidence at 10th, 20th, and 30th examination was 7.9%, 15.2%, and 24.1%, respectively. Presence of renal impairment was found to be one of risk factors for adverse reactions. The estimated hazard of overall adverse reaction gradually decreased until around 10th exposure and rose with subsequent exposures. The estimated hazard of hypersensitivity showed V-shaped change with cumulative number of exposures. The estimated hazard of physiologic reaction had a tendency toward decreasing and that of other reaction had a tendency toward increasing. Second adverse reaction was more severe than the initial in only one among 130 patients receiving subsequent injections. Conclusion Repeated exposures to iodinated contrast media increase the risk of adverse reaction. PMID:24098420
Keyes, Samuel D; Gostling, Neil J; Cheung, Jessica H; Roose, Tiina; Sinclair, Ian; Marchant, Alan
2017-06-01
The use of in vivo X-ray microcomputed tomography (μCT) to study plant root systems has become routine, but is often hampered by poor contrast between roots, soil, soil water, and soil organic matter. In clinical radiology, imaging of poorly contrasting regions is frequently aided by the use of radio-opaque contrast media. In this study, we present evidence for the utility of iodinated contrast media (ICM) in the study of plant root systems using μCT. Different dilutions of an ionic and nonionic ICM (Gastrografin 370 and Niopam 300) were perfused into the aerial vasculature of juvenile pea plants via a leaf flap (Pisum sativum). The root systems were imaged via μCT, and a variety of image-processing approaches used to quantify and compare the magnitude of the contrast enhancement between different regions. Though the treatment did not appear to significantly aid extraction of full root system architectures from the surrounding soil, it did allow the xylem and phloem units of seminal roots and the vascular morphology within rhizobial nodules to be clearly visualized. The nonionic, low-osmolality contrast agent Niopam appeared to be well tolerated by the plant, whereas Gastrografin showed evidence of toxicity. In summary, the use of iodine-based contrast media allows usually poorly contrasting root structures to be visualized nondestructively using X-ray μCT. In particular, the vascular structures of roots and rhizobial nodules can be clearly visualized in situ.
Dubose, Cheryl
2011-01-01
The growing popularity and use of social media tools such as Facebook, YouTube, Twitter, blogging, and wikis have led to a social media revolution. Given this widespread influence, it is important for educators, administrators, and technologists to understand the risks of using social media in the classroom and workplace. To investigate popular social media sites and their effect on radiologic technology education and business practices. A comprehensive search of literature was performed to examine social media and its applications in education, health care, and business. Social media use is on the rise, affecting all aspects of mainstream society. Leaders in the radiologic sciences should be familiar with social media and cognizant of its risks. Future studies regarding social media use in the radiologic sciences are necessary to determine its effect on the radiologic science community. ©2011 by the American Society of Radiologic Technologists.
Yamaguchi, Naoto; Fukushima, Yasuhiro; Yamaguchi, Aiko; Nagasawa, Naoki; Taketomi-Takahashi, Ayako; Suto, Takayuki; Tsushima, Yoshito
2017-01-01
To assess the incidence and types of sensation of smell and taste during i.v. injection of five kinds of contrast media (CM) in CT examinations. 735 patients who underwent contrast-enhanced CT (CE-CT) between 14 March 2016 and 5 April 2016 were enrolled. Medical staff asked patients whether they felt heat sensation and sensation of smell and taste during i.v. injection of CM (one of the following: iopromide, iomeprol, iopamidol, iohexol and ioversol) after their CE-CT. If the patients stated having felt the sensation of smell or taste, they were also asked what kind of smell or taste they sensed. Next, 30 ml of each CM was poured into high-purity pet cups for radiological technologists to smell directly. Radiological technologists were asked whether or not each CM had any smell. The sensations of smell and taste incidence for iopromide were 24.3% and 18.9%, respectively, which were significantly higher than those for other CM (p < 0.05). The highest incidence of the sensation of smell was medicine-ish, and the most frequently noted taste was bitterness. All radiological technologists could directly smell only iopromide, which has an ether group on a side chain and fewer hydroxyl groups. Iopromide showed a higher incidence of sensation of smell and taste than other CM. Advances in knowledge: This was the first investigation of sensation of smell and taste during i.v. injection of CM, and a specific CM showed a higher incidence, which is suspected to be due to its chemical structure.
Yamaguchi, Naoto; Yamaguchi, Aiko; Nagasawa, Naoki; Taketomi-Takahashi, Ayako; Suto, Takayuki; Tsushima, Yoshito
2017-01-01
Objective: To assess the incidence and types of sensation of smell and taste during i.v. injection of five kinds of contrast media (CM) in CT examinations. Methods: 735 patients who underwent contrast-enhanced CT (CE-CT) between 14 March 2016 and 5 April 2016 were enrolled. Medical staff asked patients whether they felt heat sensation and sensation of smell and taste during i.v. injection of CM (one of the following: iopromide, iomeprol, iopamidol, iohexol and ioversol) after their CE-CT. If the patients stated having felt the sensation of smell or taste, they were also asked what kind of smell or taste they sensed. Next, 30 ml of each CM was poured into high-purity pet cups for radiological technologists to smell directly. Radiological technologists were asked whether or not each CM had any smell. Results: The sensations of smell and taste incidence for iopromide were 24.3% and 18.9%, respectively, which were significantly higher than those for other CM (p < 0.05). The highest incidence of the sensation of smell was medicine-ish, and the most frequently noted taste was bitterness. All radiological technologists could directly smell only iopromide, which has an ether group on a side chain and fewer hydroxyl groups. Conclusion: Iopromide showed a higher incidence of sensation of smell and taste than other CM. Advances in knowledge: This was the first investigation of sensation of smell and taste during i.v. injection of CM, and a specific CM showed a higher incidence, which is suspected to be due to its chemical structure. PMID:27805431
Hosogoe, Shogo; Hatakeyama, Shingo; Kusaka, Ayumu; Hamano, Itsuto; Tanaka, Yoshimi; Hagiwara, Kazuhisa; Hirai, Hideaki; Morohashi, Satoko; Kijima, Hiroshi; Yamamoto, Hayato; Tobisawa, Yuki; Yoneyama, Tohru; Yoneyama, Takahiro; Hashimoto, Yasuhiro; Koie, Takuya; Ohyama, Chikara
2017-07-25
A quantitative tumor response evaluation to molecular-targeting agents in advanced renal cell carcinoma (RCC) is debatable. We aimed to evaluate the relationship between radiologic tumor response and pathological response in patients with advanced RCC who underwent presurgical therapy. Of 34 patients, 31 underwent scheduled radical nephrectomy. Presurgical therapy agents included axitinib (n = 26), everolimus (n = 3), sunitinib (n = 1), and axitinib followed by temsirolimus (n = 1). The major presurgical treatment-related adverse event was grade 2 or 3 hypertension (44%). The median radiologic tumor response by RECIST, Choi, and CMER were -19%, -24%, and -49%, respectively. Among the radiologic tumor response tests, CMER showed a higher association with tumor necrosis in surgical specimens than others. Ki67/MIB1 status was significantly decreased in surgical specimens than in biopsy specimens. The magnitude of the slope of the regression line associated with the tumor necrosis percentage was greater in CMER than in Choi and RECIST. Between March 2012 and December 2016, we prospectively enrolled 34 locally advanced and/or metastatic RCC who underwent presurgical molecular-targeting therapy followed by radical nephrectomy. Primary endpoint was comparison of radiologic tumor response among Response Evaluation Criteria in Solid Tumors (RECIST), Choi, and contrast media enhancement reduction (CMER). Secondary endpoint included pathological downstaging, treatment related adverse events, postoperative complications, Ki67/MIB1 status, and tumor necrosis. CMER may predict tumor response after presurgical molecular-targeting therapy. Larger prospective studies are needed to develop an optimal tumor response evaluation for molecular-targeting therapy.
Lukasiewicz, A; Lebkowska, U; Galar, M
2012-01-01
Some of the adverse clinical effects of intravascular radiological contrast agents include the interference of these contrast media with normal hemostatic processes. The aim of this report was to investigate in vivo whether a non-ionic iodinated contrast agent possess prothrombotic or anticoagulant properties. Hemostatic parameters: vWF (von Willebrand factor), F1+2 (prothrombin fragments 1+2), TAT (thrombin-antithrombin complexes), D-Dimer, β-TG (beta-thromboglobulin) were measured in a group of 35 patients. Blood samples for laboratory investigations were collected before and 30 min after the administration of a iodine contrast agent. There was observed statistically highly significant contrast-induced increase in TAT and F1+2 (p = 0.005 and p = 0.008, respectively). D-Dimer increase and decrease of β-TG and vWF after contrast medium administration were non significant. The volume of contrast medium has no influence on the assessed hemostatic parameters, while the type of contrast medium and/or the route of the contrast administration may significantly affect hemostatic parameters. We found significant effects of non-ionic agents on hemostatic activation. These effects may be important for adverse reactions and for thromboembolic complications.
Iodinated contrast media and their adverse reactions.
Singh, Jagdish; Daftary, Aditya
2008-06-01
Cross-use of technology between nuclear medicine and radiology technologists is expanding. The growth of PET/CT and the increasing use of intravenous contrast agents during these procedures bring the nuclear medicine technologist into direct contact with these agents and their associated complications. A basic understanding of the occurrence, risk factors, clinical features, and management of these procedures is of increasing importance to the nuclear medicine technologist. After reading this article, the technologist will be able to list the factors that increase the risk of contrast reactions; understand ways to minimize the occurrence of contrast reactions; and develop a plan to identify, treat, and manage the reactions effectively.
Wangsuphachart, S
1991-12-01
The cost-effectiveness of three alternative policies for the use of intravenous contrast media for urography and enhanced computerized tomography (CT) are analyzed. Alternative #1 is to use high osmolar contrast media (HOCM) in all patients, the historical policy. Alternative #2 is to replace it with low osmolar contrast media (LOCM) in all patients. Alternative #3 is to use LOCM only in the high risk patients. Data on the 6,242 patients who underwent intravenous urography and enhanced CT at the Department of Radiology, Chulalongkorn Hospital in 1989 were used. Both societal and hospital viewpoints were analyzed. The incremental cost-effectiveness (ICE) between #2 and #1 was 26,739 Baht (US$1,070) per healthy day saved (HDS), while the ICE between #3 and #1 was 12,057 Baht (US$482) per HDS. For fatal cases only, ICE between #2 and #1 was 35,111 Baht (US$1,404) per HDS, while the ICE between #3 and #1 was 18,266 Baht (US$731) per HDS. The incremental cost (IC) per patient was 2,341 Baht (US$94) and 681 Baht (US$27) respectively. For the hospital viewpoint the ICE between #2 and #1 was 13,744 (US$550) and between #3 and #1 was 6,127 Baht (US$245) per HDS. The IC per patient was 1,203 Baht (US$48) and 346 Baht (US$14), respectively. From the sensitivity analysis, #3 should be used if the LOCM price is reduced more than 75% (equal to 626 Baht or less) and more than 80% of the patients are able to pay for the contrast media.
Off-label use of intravascular iodinated organic and MR contrast media.
Tamburrini, O; Aprile, I; Falcone, C; Console, D; Rotundo, A; Rotondo, A
2011-02-01
This paper analyses off-label prescribing of the iodinated organic and magnetic resonance (MR) contrast media used in diagnostic imaging and evaluates the liability profiles and medicolegal issues associated with such use. The term off-label generally indicates the use of known drugs for which new scientific evidence suggests use in a manner and in clinical scenarios not explicitly addressed by the drug data sheet and is outside the indications for which the medication was approved. In addition, the term also indicates the use of drugs with a different route of administration and dosage from those indicated in the information leaflet. Intravascular contrast media used in diagnostic imaging are drugs in the complete sense of the term, even though they have unique characteristics which in many ways distinguish them from other pharmacological agents. The off-label use of contrast media in diagnostic imaging is a little-investigated field and most commonly, but not exclusively, applies to gadolinium-based contrast media used in MR angiography as well as cardiac and paediatric applications. In particular, the off-label use of contrast media mostly concerns deviations from the recommended dose. As contrast media are to all effects pharmaceutical agents, their off-label use can be considered admissible within the limitations laid down by the Italian law in force (Article 3 of Law 94/98) and its interpretation, i.e. the following criteria must be present: the lack of a valid diagnostic alternative; written informed consent by the patient; the presence of scientific publications validated at the international level; assumption of responsibility by the radiologist. The use of contrast media in modern image-guided medicine is essential. In cases in which the information contained in the information leaflet is modified and updated in any way whatsoever (indications, dosage, at others), specifically if restrictions are introduced in accordance with the law in force, the pharmaceutical industry must provide formal and timely notification to radiologists. On their part as prescribers and users of contrast media, radiologists must remain up to date regarding any changes in indications, dosage and route of administration. Lastly, we propose that the radiology report includes not only the type but also the dose of contrast medium used.
Implications of iodinated contrast media extravasation in the emergency department.
Sonis, Jonathan D; Gottumukkala, Ravi V; Glover, McKinley; Yun, Brian J; White, Benjamin A; Kalra, Mannudeep K; Otrakji, Alexi; Raja, Ali S; Prabhakar, Anand M
2018-02-01
To characterize the management, outcomes, and emergency department (ED) length of stay (LOS) following iodinated contrast media extravasation events in the ED. All ED patients who developed iodinated contrast media extravasation following contrast-enhanced CT (CECT) from October 2007-December 2016 were retrospectively identified. Medical records were reviewed and management, complications, frequency of surgical consultation, and ED LOS were quantified using descriptive statistics. The Wilcoxon rank sum test was used to compare ED LOS in patients who did and did not receive surgical consultation. A total of 199 contrast extravasation episodes occurred in ED patients during the 9-year study period. Of these, 42 patients underwent surgical consultation to evaluate the contrast extravasation event. No patient developed progressive symptoms, compartment syndrome, or tissue necrosis, and none received treatment beyond supportive care (warm/cold packs, elevation, compression). Median ED LOS for patients who did and did not receive surgical consultation was 11.3h versus 9.0h, respectively (p<0.01). Close observation and supportive care are sufficient for contrast extravasation events in the ED without concerning symptoms (progressive pain/swelling, altered tissue perfusion, sensory changes, or blistering/ulceration). Routine surgical consultation is likely unnecessary in the absence of these symptoms - concordant with the current American College of Radiology guidelines - and may be associated with longer ED LOS without impacting management. Copyright © 2017 Elsevier Inc. All rights reserved.
Sesé, L; Gaouar, H; Autegarden, J-E; Alari, A; Amsler, E; Vial-Dupuy, A; Pecquet, C; Francès, C; Soria, A
2016-03-01
The diagnosis of HSR to iodinated contrast media (ICM) is challenging based on clinical history and skin tests. This study evaluates the negative predictive value (NPV) of skin tests and intravenous provocation test (IPT) with low-dose ICM in patients with suspected immediate hypersensitivity reaction (HSR) to ICM. Thirty-seven patients with suspected immediate hypersensitivity reaction to ICM were included retrospectively. Skin tests and a single-blind placebo-controlled intravenous provocation test (IPT) with low-dose iodinated contrast media (ICM) were performed. Skin tests with ICM were positive in five cases (one skin prick test and five intradermal test). Thirty-six patients were challenged successfully by IPT, and only one patient had a positive challenge result, with a grade I reaction by the Ring and Messmer classification. Ten of 23 patients followed up by telephone were re-exposed to a negative tested ICM during radiologic examination; two experienced a grade I immediate reaction. For immediate hypersensitivity reaction to ICM, the NPV for skin tests and IPT with low dose was 80% (95% CI 44-97%). © 2016 John Wiley & Sons Ltd.
Glover, McKinley; Choy, Garry; Boland, Giles W; Saini, Sanjay; Prabhakar, Anand M
2015-05-01
This study assesses the prevalence of use of the most commonly used social media sites among private radiology groups (PRGs) and academic radiology departments (ARDs). The 50 largest PRGs and the 50 ARDs with the highest level of funding from the National Institutes of Health were assessed for presence of a radiology-specific social media account on Facebook, Twitter, Instagram, Pinterest, YouTube, and LinkedIn. Measures of organizational activity and end-user activity were collected, including the number of posts and followers, as appropriate; between-group comparisons were performed. PRGs adopted Facebook 12 months earlier (P = .02) and Twitter 18 months earlier (P = .02) than did ARDs. A total of 76% of PRGs maintained ≥1 account on the social media sites included in the study, compared with 28% of ARDs (P < .0001). The prevalence of having an account on the social media sites for PRGs was: Facebook, 66%; LinkedIn, 56%; Twitter, 42%; YouTube, 20%; Pinterest, 4%; and Instagram, 2%. The prevalence of radiology-specific social media accounts for ARDs was: Facebook, 18%; LinkedIn, 0%; Twitter, 24%; YouTube, 6%; Pinterest, 0%; and Instagram, 0%. There was no significant difference between ARDs and PRGs in measures of end-user or organizational activity on Facebook or Twitter. Use of social media in health care is emerging as mainstream, with PRGs being early adopters of Facebook and Twitter in comparison with ARDs. Competitive environments and institutional policies may be strong factors that influence how social media is used by radiologists at the group and department levels. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
History and Evolution of the Barium Swallow for Evaluation of the Pharynx and Esophagus.
Levine, Marc S; Rubesin, Stephen E
2017-02-01
This article reviews the history of the barium swallow from its early role in radiology to its current status as an important diagnostic test in modern radiology practice. Though a variety of diagnostic procedures can be performed to evaluate patients with dysphagia or other pharyngeal or esophageal symptoms, the barium study has evolved into a readily available, non-invasive, and cost-effective technique that can facilitate the selection of additional diagnostic tests and guide decisions about medical, endoscopic, or surgical management. This article focuses on the evolution of fluoroscopic equipment, radiography, and contrast media for evaluating the pharynx and esophagus, the importance of understanding pharyngoesophageal relationships, and major advances that have occurred in the radiologic diagnosis of select esophageal diseases, including gastroesophageal reflux disease, infectious esophagitis, eosinophilic esophagitis, esophageal carcinoma, and esophageal motility disorders.
The sharing of radiological images by professional mixed martial arts fighters on social media.
Rahmani, George; Joyce, Cormac W; McCarthy, Peter
2017-06-01
Mixed martial arts is a sport that has recently enjoyed a significant increase in popularity. This rise in popularity has catapulted many of these "cage fighters" into stardom and many regularly use social media to reach out to their fans. An interesting result of this interaction on social media is that athletes are sharing images of their radiological examinations when they sustain an injury. To review instances where mixed martial arts fighters shared images of their radiological examinations on social media and in what context they were shared. An Internet search was performed using the Google search engine. Search terms included "MMA," "mixed martial arts," "injury," "scan," "X-ray," "fracture," and "break." Articles which discussed injuries to MMA fighters were examined and those in which the fighter themselves shared a radiological image of their injury on social media were identified. During our search, we identified 20 MMA fighters that had shared radiological images of their injuries on social media. There were 15 different types of injury, with a fracture of the mid-shaft of the ulna being the most common. The most popular social media platform was Twitter. The most common imaging modality X-ray (71%). The majority of injuries were sustained during competition (81%) and 35% of these fights resulted in a win for the fighter. Professional mixed martial artists are sharing radiological images of their injuries on social media. This may be in an attempt to connect with fans and raise their profile among other fighters.
Howlett, David; Vincent, Tim; Watson, Gillian; Owens, Emma; Webb, Richard; Gainsborough, Nicola; Fairclough, Jil; Taylor, Nick; Miles, Ken; Cohen, Jon; Vincent, Richard
2011-06-01
To review the initial experience of blending a variety of online educational techniques with traditional face to face or contact-based teaching methods to deliver final year undergraduate radiology content at a UK Medical School. The Brighton and Sussex Medical School opened in 2003 and offers a 5-year undergraduate programme, with the final 5 spent in several regional centres. Year 5 involves several core clinical specialities with onsite radiology teaching provided at regional centres in the form of small-group tutorials, imaging seminars and also a one-day course. An online educational module was introduced in 2007 to facilitate equitable delivery of the year 5 curriculum between the regional centres and to support students on placement. This module had a strong radiological emphasis, with a combination of imaging integrated into clinical cases to reflect everyday practice and also dedicated radiology cases. For the second cohort of year 5 students in 2008 two additional online media-rich initiatives were introduced, to complement the online module, comprising imaging tutorials and an online case discussion room. In the first year for the 2007/2008 cohort, 490 cases were written, edited and delivered via the Medical School managed learning environment as part of the online module. 253 cases contained a form of image media, of which 195 cases had a radiological component with a total of 325 radiology images. Important aspects of radiology practice (e.g. consent, patient safety, contrast toxicity, ionising radiation) were also covered. There were 274,000 student hits on cases the first year, with students completing a mean of 169 cases each. High levels of student satisfaction were recorded in relation to the online module and also additional online radiology teaching initiatives. Online educational techniques can be effectively blended with other forms of teaching to allow successful undergraduate delivery of radiology. Efficient IT links and good image quality are essential ingredients for successful student/clinician engagement. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Beyer, Lukas Philipp; Wassermann, Florian; Pregler, Benedikt; Michalik, Katharina; Rennert, Janine; Wiesinger, Isabel; Stroszczynski, Christian; Wiggermann, Philipp; Jung, Ernst Michael
2017-12-01
The purpose of this study was to compare contrast-enhanced ultrasound (CEUS), magnetic resonance imaging (MRI) using liver-specific contrast agent and a combination of both for the characterization of focal liver lesions (FLL). 83 patients with both benign and malignant liver lesions were examined using CEUS and MRI after the intravenous administration of liver-specific contrast media. All patients had inconclusive results from prior imaging examinations. Histopathological specimens could be obtained in 53 patients. Ultrasound was performed using a multi-frequency curved probe (1 - 6 MHz) after the injection of 1 - 2.4 ml ultrasound contrast media. The sensitivity, specificity, positive predictive value and negative predictive value of CEUS, MRI and a combination of both (CEUS + MRI) were compared. The sensitivity, specificity, positive and negative predictive values regarding lesion classification were 90.9 %, 70.6 %, 92.3 % and 66.6 %, respectively, for CEUS; 90.9 %, 82.4 %, 95.2 % and 70.0 %, respectively, for MRI; and 96.9 %, 70.6 %, 92.7 % and 85.7 % respectively, for CEUS + MRI. There were no statistically significant differences. 6 malignant lesions were missed using CEUS or MRI alone (false negatives). The use of both modalities combined reduced the false-negative results to 2. CEUS and MRI with liver-specific contrast media are very reliable and of equal informative value in the characterization of focal liver lesions. The number of false-negative results can be decreased using a combination of the two methods. © Georg Thieme Verlag KG Stuttgart · New York.
The sharing of radiological images by professional mixed martial arts fighters on social media
Joyce, Cormac W; McCarthy, Peter
2017-01-01
Background Mixed martial arts is a sport that has recently enjoyed a significant increase in popularity. This rise in popularity has catapulted many of these “cage fighters” into stardom and many regularly use social media to reach out to their fans. An interesting result of this interaction on social media is that athletes are sharing images of their radiological examinations when they sustain an injury. Purpose To review instances where mixed martial arts fighters shared images of their radiological examinations on social media and in what context they were shared. Material and Methods An Internet search was performed using the Google search engine. Search terms included “MMA,” “mixed martial arts,” “injury,” “scan,” “X-ray,” “fracture,” and “break.” Articles which discussed injuries to MMA fighters were examined and those in which the fighter themselves shared a radiological image of their injury on social media were identified. Results During our search, we identified 20 MMA fighters that had shared radiological images of their injuries on social media. There were 15 different types of injury, with a fracture of the mid-shaft of the ulna being the most common. The most popular social media platform was Twitter. The most common imaging modality X-ray (71%). The majority of injuries were sustained during competition (81%) and 35% of these fights resulted in a win for the fighter. Conclusion Professional mixed martial artists are sharing radiological images of their injuries on social media. This may be in an attempt to connect with fans and raise their profile among other fighters. PMID:28717518
van Kaick, G; Delorme, S
2016-12-01
Detection of gadolinium deposits in patients who have repeatedly been administered intravenous gadolinium chelates have given rise to concern regarding the long-term safety of magnetic resonance imaging (MRI) contrast media. Nevertheless, negative long-term clinical effects have not yet been observed. In some publications parallels have been drawn to the sequelae of thorotrast that was formerly used for arterial angiography. In this article the history of thorotrast use is briefly described and in particular why, despite warnings, this substance was used frequently and worldwide. A brief summary of the results of the German Thorotrast Study revealed that high excess rates were only observed for primary malignant liver tumors after a 15-year or longer latency period and to a lesser degree of leukemias, as well as for severe local complications due to paravascular injections, particularly in the neck region. Based on this historical review, we will venture to take stock of the outcome from the "success story" of this contrast agent.
Prevention of Contrast-Induced Nephropathy (CIN) in Interventional Radiology Practice
Gupta, Rajan K.; Bang, Tami J.
2010-01-01
Contrast-induced nephropathy (CIN) is a widely recognized and clinically significant problem in patients undergoing an increasing number of minimally invasive procedures that require contrast administration. Contrast-induced nephropathy is the third most common cause of hospital-acquired renal failure and has significant prognostic implications on patient outcomes. Interventional practitioners are faced with challenging decisions regarding prophylaxis and patient management. The major risk factor for developing CIN is preexisting renal dysfunction, particularly in association with diabetes. Patients are considered to be at risk when estimated glomerular filtration rate (eGFR) or estimated creatinine clearance (eCCr) is less than 60. The cornerstone of prevention of CIN is appropriate risk stratification, intravenous hydration with normal saline or sodium bicarbonate, appropriate withholding of nephrotoxic medications, use of low or iso-osmolar contrast media, and various intraprocedural methods for iodinated contrast dose reduction. Although N-acetylcysteine administration is popular, it remains unproven. Practitioners must be familiar with prevention strategies and diagnosis of CIN to minimize its clinical impact. PMID:22550376
Using Social Media to Share Your Radiology Research: How Effective Is a Blog Post?
Hoang, Jenny K; McCall, Jonathan; Dixon, Andrew F; Fitzgerald, Ryan T; Gaillard, Frank
2015-07-01
The aim of this study was to compare the volume of individuals who viewed online versions of research articles in 2 peer-reviewed radiology journals and a radiology blog promoted by social media. The authors performed a retrospective study comparing online analytic logs of research articles in the American Journal of Neuroradiology (AJNR) and the American Journal of Roentgenology (AJR) and a blog posting on Radiopaedia.org from April 2013 to September 2014. All 3 articles addressed the topic of reporting incidental thyroid nodules detected on CT and MRI. The total page views for the research articles and the blog article were compared, and trends in page views were observed. Factors potentially affecting trends were an AJNR podcast and promotion of the blog article on the social media platforms Facebook, Tumblr, and Twitter to followers of Radiopaedia.org in February 2014 and August 2014. The total numbers of page views during the study period were 2,421 for the AJNR article and 3,064 for the AJR article. The Radiopaedia.org blog received 32,675 page views, which was 13.6 and 10.7 times greater than AJNR and AJR page views, respectively, and 6.0 times greater than both journal articles combined. Months with activity above average for the blog and the AJNR article coincided with promotion by Radiopaedia.org on social media. Dissemination of scientific material on a radiology blog promoted on social media can substantially augment the reach of more traditional publication venues. Although peer-reviewed publication remains the most widely accepted measure of academic productivity, researchers in radiology should not ignore opportunities for increasing the impact of research findings via social media. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Ozutemiz, Can; Dicle, Oguz; Koremezli, Nevin
2015-01-01
To evaluate the frequency of mobile technology and social media usage among radiology residents and their access to professional information. A questionnaire consisting of 24 questions prepared using Google Drive was sent via e-mail to 550 radiology residents throughout the country. Of the 176 participating residents, 74 completed the survey via the internet, and 102 completed it at three different national radiology meetings. Response rates and its relationship with responses given to different questions were assessed. Hundred two male and 74 female residents participated in the survey. 141 (81.3%) residents thought that they had appropriate internet access in their department. The number of residents using a smartphone was 153 (86.9%). The android operating system (70, 45.8%) was the preferred operating system of respondants. Only 24 (15.7%) of the smartphone users thought that there were enough radiology related applications. "Radiology assistant" (18.9%), "Radiopedia" (7.8%) and "Radiographics" (7.8%) were the most utilized applications. Of the smartphone users, 87(56.9%) stated that they used cell phones in order to find radiological information, and the most used web pages were Google (165, 93.8%), Radiopaedia.org (129, 73.3%), Radiologyassistant.nl (135, 76.7%), and Pubmed (114, 64.8%). Social media usages were as follows: None (10, 5.7%), Facebook (139, 79%), Twitter (55, 31.3%), Google + (51, 29%) and YouTube (44, 25%). While smartphone usage rates among the residents were high, the use of radiology specific applications was not common. Social media usage was very common among residents.
Improving education for the management of contrast reactions: an online didactic model.
Niell, Bethany L; Vartanians, Vartan M; Halpern, Elkan P
2014-02-01
Radiologists could improve their knowledge of contrast reaction management. The aim of this study was to evaluate to what degree the implementation of a didactic module resulted in improved technologist, nurse, and physician knowledge and comfort levels regarding the appropriate management of adverse reactions to contrast media. After institutional review board approval was obtained, nurses, technologists, and physicians involved in contrast administration were required to complete the educational module. Premodule and postmodule assessments were designed online. Each assessment included knowledge-based questions regarding the appropriate management of different types of contrast reactions, as well as questions regarding each respondent's comfort level with the treatment of various types of adverse contrast reactions. Comfort level was measured using a 6-point, Likert-type scale. Premodule and postmodule assessment scores were compared using McNemar's test. After module completion, physicians demonstrated a statistically significant improvement in knowledge regarding the proper administration route, concentration, and dose of intramuscular epinephrine. Physicians demonstrated significantly increased comfort with the administration of intramuscular epinephrine to adult and pediatric patients after module completion (P < .05). Module completion resulted in statistically significant improvements in respondents' comfort levels with the treatment of an adverse reaction to contrast media, although 19% of personnel still reported feeling uncomfortable after completing the module. Didactic instruction in contrast reaction management results in improved knowledge and comfort levels for physicians, nurses, and technologists. However, a significant percentage of personnel still reported feeling uncomfortable treating an adverse contrast reaction after module completion, suggesting that didactic instruction alone may be inadequate. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.
White Paper: Radiological Curriculum for Undergraduate Medical Education in Germany.
Ertl-Wagner, B; Barkhausen, J; Mahnken, A H; Mentzel, H J; Uder, M; Weidemann, J; Stumpp, P
2016-11-01
Purpose: Radiology represents a highly relevant part of undergraduate medical education from preclinical studies to subinternship training. It is therefore important to establish a content base for teaching radiology in German Medical Faculties. Materials and Methods: The German Society of Radiology (DRG) developed a model curriculum for radiological teaching at German medical universities, which is presented in this article. There is also a European model curriculum for undergraduate teaching (U-level curriculum of the European Society of Radiology). In a modular concept, the students shall learn important radiological core principles in the realms of knowledge, skills and competences as well as core scientific competences in the imaging sciences. Results: The curriculum is divided into two modules. Module 1 includes principles of radiation biology, radiation protection and imaging technology, imaging anatomy as well as the risks and side effects of radiological methods, procedures and contrast media. This module is modality-oriented. Module 2 comprises radiological diagnostic decision-making and imaging-based interventional techniques for various disease entities. This module is organ system-oriented. Conclusion: The curriculum is meant as a living document to be amended and revised at regular intervals. The curriculum can be used as a basis for individual curricular development at German Medical Faculties. It can be integrated into traditional or reformed medical teaching curricula. Key Points: • Radiology is an integral and important part of medical education.• The German Society of Radiology (DRG) developed a model curriculum for teaching radiology at German Medical Faculties to help students develop the ability to make medical decisions based on scientific knowledge and act accordingly.• This curriculum can be used for individual curricular development at medical departments. It is divided into two modules with several chapters. Citation Format: • Ertl-Wagner B, Barkhausen J, Mahnken AH et al. White Paper: Radiological Curriculum for Undergraduate Medical Education in Germany. Fortschr Röntgenstr 2016; 188: 1017 - 1023. © Georg Thieme Verlag KG Stuttgart · New York.
Chang, D-H; Kabbasch, C; Bovenschulte, H; Libicher, M; Maintz, D; Bangard, C
2013-05-01
Evaluation of complications, patient satisfaction and clinical benefit of port systems with authorization for high pressure injection of contrast agent during CT/MR examinations. Ultrasound-guided insertions of central venous port catheters were performed through the lateral subclavian vein at a university teaching hospital. The radiological information system (HIS/RIS) was used to evaluate technical success and complication rates. Assessment of patient satisfaction and clinical benefit was carried out by a questionnaire during a telephone call 6 months after implantation of the port system. A total of 195 port systems in 193 patients were implanted. The catheter remained in place for a mean duration of 169 days (overall 29,210 catheter days). The technical success rate was 99.5 % and the overall complication rate was 17.4 % (24/138; 0.82 per 1000 catheter days). Follow-up revealed 13 early port explantations (9 %). Most of the patients reported high satisfaction in general (satisfied/very satisfied: 94 %). 34/209 contrast-enhanced CT/MRT scans (16 %) were performed using the port for contrast media injection. There were no complications during or after administration of contrast agent via the port system. The Powerport system is a safe alternative for peripheral i. v. contrast media injection during CT/MR scans, but has been infrequently used. Most patients reported high overall satisfaction with the port system. © Georg Thieme Verlag KG Stuttgart · New York.
Kalia, Vivek; Carrino, John A.; Macura, Katarzyna J.
2015-01-01
Purpose The purpose of this study was to survey current practices for portable media (CDs and DVDs) use for medical imaging in both academic and nonacademic radiology departments in the United States. Methods This survey was a stratified, nonrandom sample, 22-question electronic survey, using SurveyMonkey, of members of the Association of Administrators in Academic Radiology, the Association for Medical Imaging Management, and the University HealthSystem Consortium, conducted in November 2009. Questions were grouped by media production and media viewing practices. Results One hundred and two individual responses to the survey were received. Ninety-eight percent of respondents said that their institutions produced Digital Imaging and Communications in Medicine (DICOM)-compliant media, with only 2.0% uncertain. Only 22.2% of respondents claimed that their institutions produced Integrating the Healthcare Enterprise (IHE) Portable Data for Imaging (PDI)-compliant media, while 71.6% were uncertain. Rates of DICOM and IHE PDI compliance did not differ between academic and nonacademic centers. As for testing digital media produced at the institutions for DICOM and IHE PDI compliance, only 16.0% of respondents’ institutions routinely did so. Conclusions Three main problem areas regarding portable media became evident from this study: (1) access, (2) importability, and (3) viewing issues, and problems with any of the 3 can delay patient care. Noncompliance and a lack of knowledge about compliance were found to be major issues in the present study, more so for IHE PDI than for DICOM, and there is much room for improvement. Recommendations include that radiology practices should routinely generate only media compliant with DICOM and IHE PDI and should test for compliance. PMID:21211763
Contrast reaction training in US radiology residencies: a COARDRI study.
LeBedis, Christina A; Rosenkrantz, Andrew B; Otero, Hansel J; Decker, Summer J; Ward, Robert J
To perform a survey-based assessment of current contrast reaction training in US diagnostic radiology residency programs. An electronic survey was distributed to radiology residency program directors from 9/2015-11/2015. 25.7% of programs responded. 95.7% of those who responded provide contrast reaction management training. 89.4% provide didactic lectures (occurring yearly in 71.4%). 37.8% provide hands-on simulation training (occurring yearly in 82.3%; attended by both faculty and trainees in 52.9%). Wide variability in contrast reaction education in US diagnostic radiology residency programs reveals an opportunity to develop and implement a national curriculum. Copyright © 2017 Elsevier Inc. All rights reserved.
Belle, Mônica B B; Leffa, Daniela D; Mazzorana, Daliane; De Andrade, Vanessa M
2013-01-01
Contrast media (CM) are frequently used in diagnostic radiology and in radiotherapy as a diagnostic tool and in treatment planning. Previous studies have demonstrated that these compounds induce chromosomal aberrations. This study evaluates the mutagenic effects induced by the contrast medium Urografina® 292 (meglumine amidotrizoate and sodium-ionic dimmer) in bone marrow cells (BMC) of mice in vivo. Micronuclei assay was performed in BMC of CF-1 mice injected with CM 1.5 and 3.0 mL/kg intravenous doses and 1.0, 2.0, 3.0 mL/kg intraperitoneal doses. The animals were beheaded 24 h after treatment by cervical dislocation, and femur BMC from each animal were used in the micronucleus test. The group treated with the highest intravenous injection of Urografina® 292 (3.0 mL/kg) presented an increase in the frequency of micronucleated polychromatic erythrocytes (MNPCEs) in relation at the control group (P<0.05). The results obtained after intraperitoneal administration of CM showed that all doses (1.0 mL/kg, 2.0 mL/kg and 3.0 mL/kg) increased the frequency of MNPCEs, being significantly different from the negative control (P< 0.01). The present results suggest that iodinated contrast media Urografina® 292 may cause a significant increase of cytogenetic damage in bone marrow cells of mice.
van der Molen, Aart J; Reimer, Peter; Dekkers, Ilona A; Bongartz, Georg; Bellin, Marie-France; Bertolotto, Michele; Clement, Olivier; Heinz-Peer, Gertraud; Stacul, Fulvio; Webb, Judith A W; Thomsen, Henrik S
2018-07-01
The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 2011 guidelines on the prevention of post-contrast acute kidney injury (PC-AKI). The results of the literature review and the recommendations based on it, which were used to prepare the new guidelines, are presented in two papers. AREAS COVERED IN PART 2: Topics reviewed include stratification of PC-AKI risk, the need to withdraw nephrotoxic medication, PC-AKI prophylaxis with hydration or drugs, the use of metformin in diabetic patients receiving contrast medium and the need to alter dialysis schedules in patients receiving contrast medium. • In CKD, hydration reduces the PC-AKI risk • Intravenous normal saline and intravenous sodium bicarbonate provide equally effective prophylaxis • No drugs have been consistently shown to reduce the risk of PC-AKI • Stop metformin from the time of contrast medium administration if eGFR < 30 ml/min/1.73 m 2 • Dialysis schedules need not change when intravascular contrast medium is given.
Terminology for contrast-enhanced sonography: a practical glossary.
Catalano, Orlando; Migaleddu, Vincenzo; Quaia, Emilio; Caruso, Giuseppe
2007-06-01
The purpose of this glossary is to offer an updated guide to the correct terminology for contrast-enhanced sonography. This report was prepared by a panel of radiologists from the Sonography Section of the Italian Association of Medical Radiology. A leading author prepared a list of terms based on a comprehensive literature survey. The draft was analyzed by 3 experts on the topic of contrast-enhanced sonography. These reviewers reached a consensus and prepared the final version. A list of 137 terms is included. These terms are briefly defined. Their proper application is discussed, with special reference to potential misleading uses. Contrast-enhanced sonography is a relatively new diagnostic tool, now entering clinical practice in several countries. Use of appropriate, universal terminology is mandatory in the scientific setting to allow comparison between different published experiences. Additionally, use of clear, standardized terminology is necessary in the clinical setting to facilitate report understanding by the referring physician. Standardized, nonequivocal nomenclature may also help future diffusion of sonographic contrast media in countries where their application is still not approved.
Use of Social Media in Radiology Education.
Ranginwala, Saad; Towbin, Alexander J
2018-01-01
Social media has become the dominant method of mass digital communication over the past decade. Public figures and corporations have learned how to use this new approach to deliver their messages directly to their followers. Recently, medical educators have begun to use social media as a means to deliver educational content directly to learners. The purpose of this article is to describe the benefits of using social media for medical education. Because each social media platform has different platform-specific constraints, several different popular social media networks are discussed. For each network, the authors discuss the basics of the platform and its benefits and disadvantages for users and provide examples of how they have used each platform to target a unique audience. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Chemical, Biological, Radiological, and Nuclear Consequence Management
The Chemical, Biological, Radiological, and Nuclear CMAD provides scientific support and technical expertise for decontamination of buildings, building contents, public infrastructure, agriculture, and associated environmental media.
Leveraging Facebook to Brand Radiology.
Tso, Hilda H; Parikh, Jay R
2018-03-30
In the current health care climate, radiologists should consider developing their brand. Facebook is the market leader for social media networking in the United States. The authors describe how radiologists can leverage Facebook to develop and market organizational, group, and individual brands. The authors then address concerns related to the use of social media by radiologists. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Rosado Ingelmo, A; Doña Diaz, I; Cabañas Moreno, R; Moya Quesada, M C; García-Avilés, C; García Nuñez, I; Martínez Tadeo, J I; Mielgo Ballesteros, R; Ortega-Rodríguez, N; Padial Vilchez, M A; Sánchez-Morillas, L; Vila Albelda, C; Moreno Rodilla, E; Torres Jaén, M J
2016-01-01
The objective of these guidelines is to ensure efficient and effective clinical practice. The panel of experts who produced this consensus document developed a research protocol based on a review of the literature. The prevalence of allergic reactions to iodinated contrast media (ICM) is estimated to be 1:170 000, that is, 0.05%-0.1% of patients undergoing radiologic studies with ICM (more than 75 million examinations per year worldwide). Hypersensitivity reactions can appear within the first hour after administration (immediate reactions) or from more than 1 hour to several days after administration (nonimmediate or delayed reactions). The risk factors for immediate reactions include poorly controlled bronchial asthma, concomitant medication (eg, angiotensin-converting enzyme inhibitors, ß-blockers, and proton-pump inhibitors), rapid administration of the ICM, mastocytosis, autoimmune diseases, and viral infections. The most common symptoms of immediate reactions are erythema and urticaria with or without angioedema, which appear in more than 70% of patients. Maculopapular rash is the most common skin feature of nonimmediate reactions (30%-90%). Skin and in vitro tests should be performed for diagnosis of both immediate and nonimmediate reactions. The ICM to be administered will therefore be chosen depending on the results of these tests, the ICM that induced the reaction (when known), the severity of the reaction, the availability of alternative ICM, and the information available on potential ICM cross-reactivity. Another type of contrast media, gadolinium derivatives, is used used for magnetic resonance imaging. Although rare, IgE-mediated reactions to gadolinium derivatives have been reported.
Marshall, Nina L; Spooner, Muirne; Galvin, P Leo; Ti, Joanna P; McElvaney, N Gerald; Lee, Michael J
2011-01-01
A preliminary audit of orders for computed tomography was performed to evaluate the typical performance of interns ordering radiologic examinations. According to the audit, the interns showed only minimal improvement after 8 months of work experience. The online radiology ordering module (ROM) program included baseline assessment of student performance (part I), online learning with the ROM (part II), and follow-up assessment of performance with simulated ordering with the ROM (part III). A curriculum blueprint determined the content of the ROM program, with an emphasis on practical issues, including provision of logistic information, clinical details, and safety-related information. Appropriate standards were developed by a committee of experts, and detailed scoring systems were devised for assessment. The ROM program was successful in addressing practical issues in a simulated setting. In the part I assessment, the mean score for noting contraindications for contrast media was 24%; this score increased to 59% in the part III assessment (P = .004). Similarly, notification of methicillin-resistant Staphylococcus aureus status and pregnancy status and provision of referring physician contact information improved significantly. The quality of the clinical notes was stable, with good initial scores. Part III testing showed overall improvement, with the mean score increasing from 61% to 76% (P < .0001). In general, medical students lack the core knowledge that is needed for good-quality ordering of radiology services, and the experience typically afforded to interns does not address this lack of knowledge. The ROM program was a successful intervention that resulted in statistically significant improvements in the quality of radiologic examination orders, particularly with regard to logistic and radiation safety issues.
Storage media for computers in radiology.
Dandu, Ravi Varma
2008-11-01
The introduction and wide acceptance of digital technology in medical imaging has resulted in an exponential increase in the amount of data produced by the radiology department. There is an insatiable need for storage space to archive this ever-growing volume of image data. Healthcare facilities should plan the type and size of the storage media that they needed, based not just on the volume of data but also on considerations such as the speed and ease of access, redundancy, security, costs, as well as the longevity of the archival technology. This article reviews the various digital storage media and compares their merits and demerits.
Storage media for computers in radiology
Dandu, Ravi Varma
2008-01-01
The introduction and wide acceptance of digital technology in medical imaging has resulted in an exponential increase in the amount of data produced by the radiology department. There is an insatiable need for storage space to archive this ever-growing volume of image data. Healthcare facilities should plan the type and size of the storage media that they needed, based not just on the volume of data but also on considerations such as the speed and ease of access, redundancy, security, costs, as well as the longevity of the archival technology. This article reviews the various digital storage media and compares their merits and demerits. PMID:19774182
Liccardi, Gennaro; Salzillo, Antonello; De Blasio, Francesco; D'Amato, Gennaro
2009-07-01
It is well known that patients suffering from bronchial asthma undergoing surgical procedures requiring general anesthesia (GA) or the administration of water soluble radiographic contrast media (RCM) have an increased risk of potentially severe bronchospasm. Nevertheless, little attention has been devoted to the possible preventive measures to reduce the occurrence of this potentially life-threatening event. It has been shown that the most important risk factor for bronchospasm during GA induction and/or the use of RCM is represented by a high degree of bronchial hyperreactivity with airway instability not adequately controlled by long-term anti-inflammatory treatment. The aim of this commentary is to underline the need for an accurate clinical and functional evaluation of asthmatics undergoing surgical procedures requiring GA or radiological procedures requiring the administration of RCM, as well as to suggest a stepwise preventive pharmacological approach for reducing the risk of bronchospasm. The authors' suggestions represent clinical experience of the respiratory section of an internal hospital-based working group whose aim is the prevention of asthmatic/anaphylactic/anaphylactoid reactions during the administration of anesthetics and/or RCM. The MEDLINE database was searched with a combination of keywords: general anesthesia, radio contrast media [and] bronchial asthma. The main limitation of this commentary is the scarcity of available literature on this topic. The authors suggest a therapeutic approach before surgical procedures requiring GA and/or RCM administration based on the degree of asthma control as assessed by clinical/functional criteria. In this setting, in addition to the necessity of obtaining the best control of airway reactivity, the authors suggest that an optimal control of asthma symptoms in 'real life' conditions might likely constitute a safety issue in asthmatic patients in the case of emergency procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fahey, F.
Fundamental knowledge of radiologic anatomy and physiology is critical for medical physicists. Many physicists are exposed to this topic only in graduate school, and knowledge is seldom formally evaluated or assessed after Part I of the ABR exam. Successful interactions with clinicians, including surgeons, radiologists, and oncologists requires that the medical physicist possess this knowledge. This course presents a review of radiologic anatomy and physiology as it applies to projection radiography, fluoroscopy, CT, MRI, U/S, and nuclear medicine. We will review structural anatomy, manipulation of tissue contrast, the marriage between anatomy and physiology, and explore how medical imaging exploits normalmore » and pathological processes in the body to generate contrast. Learning Objectives: Review radiologic anatomy. Examine techniques to manipulate tissue contrast in radiology. Integrate anatomy and physiology in molecular imaging.« less
Sendur, M A N; Aksoy, S; Yaman, S; Arik, Z; Tugba Kos, F; Akinci, M B; Civelek, B; Yildirim Ozdemir, N; Uncu, D; Zengin, N
2013-01-01
There is a clinical need to predict the probability of cisplatin-induced nephrotoxicity (CIN) in order to make decisions about patient management and relevant preventive measures. The purpose of this study was to develop a risk prediction methodology of CIN. 197 consecutive cancer patients, whose serum creatinine was measured at least 48 h before every cycle of cisplatin-based chemotherapy, were included in the study. Demographic and clinical data were collected from the patient medical records. Renal function was evaluated at least 48 h before treatment (day 0) of each cycle, based on the Modification of Diet in Renal Disease (MDRD) formula. CIN was defined as a decrease of ≥ 25% in glomerular filtration rate (GFR) compared to baseline GFR values. The mean age of the study population was 54.5±9.6 years. Fifty-eight patients (29.4%) whose GFR had decreased by at least 25% compared to baseline values formed the CIN group, and the remaining 139 patients formed the non-CIN group. No significant differences were noted between the CIN and non-CIN groups in terms of age, gender, body mass index and smoking history. Metastatic disease was similar in both groups (p=0.86). History of hypertension (p=0.81), diabetes mellitus (p=0.72), and cardiovascular disease (p=0.58) were similar in the two groups. Chemotherapeutic agents used concurrently with cisplatin were similar in both groups. Significantly more radiologic examinations using contrast media were performed in the CIN group compared with the non-CIN group (p=0.01). In patients exposed to contrast media within a week before cisplatin administration, the risk of CIN was 2.56-fold higher (957 percent; CI 1.28-5.11) than in patients without such exposure (p=0.009). In patients with exposure to contrast media within a week before cisplatin administration, the risk of CIN was significantly higher than in patients without such an exposure. No additional risk factors for CIN were found in this retrospective observational study.
Zhang, Bin; Dong, Yuhao; Liang, Long; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Chen, Wenbo; Li, Xinyu; Liang, Changhong; Zhang, Shuixing
2016-03-01
Some epidemiologic surveillance studies have recorded adverse drug reactions to radiocontrast agents. We aimed to investigate the incidence and management of acute adverse reactions (AARs) to Ultravist-370 and Isovue-370 in patients who underwent contrast-enhanced computed tomography (CT) scanning.Data from 137,473 patients were analyzed. They had undergone enhanced CT scanning with intravenous injection of Ultravist-370 or Isovue-370 during the period of January 1, 2006 to December 31, 2012 in our hospital. We investigated and classified AARs according to the American College of Radiology and the Chinese Society of Radiology (CSR) guidelines for iodinated contrast media. We analyzed risk factors for AARs and compared the AARs induced by Ultravist-370 and Isovue-370.Four hundred and twenty-eight (0.31%) patients experienced AARs, which included 330 (0.24%) patients with mild AARs, 82 (0.06%) patients with moderate AARs, and 16 (0.01%) patients with severe AARs (including 3 cases of cardiac arrest and one case of death). The incidence of AARs was higher with Ultravist-370 than with Isovue-370 (0.38% vs 0.24%, P < 0.001), but only for mild AARs (0.32% vs 0.16%, P < 0.001). Analyses on risk factors indicated that female patients (n = 221, 0.43%, P < 0.001), emergency patients (n = 11, 0.51%, P < 0.001), elderly patients aged 50 to 60 years (n = 135, 0.43%, P < 0.001), and patients who underwent coronary computed tomography angiography (CTA) (n = 55, 0.51%, P < 0.001) had a higher risk of AARs. Cutaneous manifestations (50.52%)-especially rash (59.74%)-were the most frequent mild AARs. Cardiovascular manifestations accounted for most moderate and severe AARs (62.91% and 48.28%, respectively). After proper management, the symptoms and signs of 96.5% of the AARs resolved within 24 hours without sequelae.Ultravist-370 and Isovue-370 are safe for patients undergoing enhanced CT scanning. The incidence of AARs is higher with Ultravist-370 than with Isovue-370, but this difference is limited only to the mild AARs. The incidence of AARs could be affected by multiple factors.
Zhang, Bin; Dong, Yuhao; Liang, Long; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Chen, Wenbo; Li, Xinyu; Liang, Changhong; Zhang, Shuixing
2016-01-01
Abstract Some epidemiologic surveillance studies have recorded adverse drug reactions to radiocontrast agents. We aimed to investigate the incidence and management of acute adverse reactions (AARs) to Ultravist-370 and Isovue-370 in patients who underwent contrast-enhanced computed tomography (CT) scanning. Data from 137,473 patients were analyzed. They had undergone enhanced CT scanning with intravenous injection of Ultravist-370 or Isovue-370 during the period of January 1, 2006 to December 31, 2012 in our hospital. We investigated and classified AARs according to the American College of Radiology and the Chinese Society of Radiology (CSR) guidelines for iodinated contrast media. We analyzed risk factors for AARs and compared the AARs induced by Ultravist-370 and Isovue-370. Four hundred and twenty-eight (0.31%) patients experienced AARs, which included 330 (0.24%) patients with mild AARs, 82 (0.06%) patients with moderate AARs, and 16 (0.01%) patients with severe AARs (including 3 cases of cardiac arrest and one case of death). The incidence of AARs was higher with Ultravist-370 than with Isovue-370 (0.38% vs 0.24%, P < 0.001), but only for mild AARs (0.32% vs 0.16%, P < 0.001). Analyses on risk factors indicated that female patients (n = 221, 0.43%, P < 0.001), emergency patients (n = 11, 0.51%, P < 0.001), elderly patients aged 50 to 60 years (n = 135, 0.43%, P < 0.001), and patients who underwent coronary computed tomography angiography (CTA) (n = 55, 0.51%, P < 0.001) had a higher risk of AARs. Cutaneous manifestations (50.52%)—especially rash (59.74%)—were the most frequent mild AARs. Cardiovascular manifestations accounted for most moderate and severe AARs (62.91% and 48.28%, respectively). After proper management, the symptoms and signs of 96.5% of the AARs resolved within 24 hours without sequelae. Ultravist-370 and Isovue-370 are safe for patients undergoing enhanced CT scanning. The incidence of AARs is higher with Ultravist-370 than with Isovue-370, but this difference is limited only to the mild AARs. The incidence of AARs could be affected by multiple factors. PMID:27015204
Tofil, Nancy M; White, Marjorie Lee; Grant, Matthew; Zinkan, J Lynn; Patel, Bhavik; Jenkins, Lynsey; Youngblood, Amber Q; Royal, Stuart A
2010-07-01
Severe reactions to radiographic contrast agents can be life threatening, and although they are rare, effective recognition and management are essential to improving outcomes. A high-fidelity radiology simulation course for radiology residents and technologists focusing on severe contrast reactions and immediate treatments was designed to test the hypothesis that knowledge would improve with this educational intervention. A prospective pretest and posttest study design was used. Residents and technologists worked in teams of three to five members. Learning objectives focused on demonstrating when and how to use basic life support skills and epinephrine auto-injectors. Each resident and technologist was administered a pretest prior to the start of the case scenarios and a posttest following the debriefing session. Scores from the pretest and posttest for the residents and technologists were compared using a paired-samples t test. Nineteen radiology residents and 11 radiology technologists participated. The average test scores were higher and improved significantly following the simulation experience for both the radiology residents (57% vs 82%, P < .001) and technologists (47% vs 72%, P = .006). Anonymous evaluations demonstrated that the experience was well received by residents and technologists, with 97% of learners (29 of 30) rating the experience as extremely or very helpful. Important learning themes included the knowledge of epinephrine auto-injector use and basic life support skills. High-fidelity simulation for radiology residents and technologists focusing on epinephrine auto-injector use and basic life support skills during the first 5 minutes of a severe contrast reaction can significantly improve recognition and knowledge in treating patients having severe contrast reactions. 2010 AUR. Published by Elsevier Inc. All rights reserved.
Diagnosis of pediatric gastric, small-bowel and colonic volvulus.
Garel, Charles; Blouet, Marie; Belloy, Frederique; Petit, Thierry; Pelage, Jean-Pierre
2016-01-01
Digestive volvulus affects the stomach, small bowel and mobile segments of the colon and often has a developmental cause. Reference radiologic examinations include upper gastrointestinal contrast series for gastric volvulus, possibly with ultrasonography for small-bowel volvulus, and contrast enema for colonic volvulus. Treatment is usually surgical. This pictorial essay describes the embryological development and discusses the clinical and radiologic presentation of volvulus, depending on location, and details the appropriate radiologic examinations.
Rubin, Geoffrey D; Krishnaraj, Arun; Mahesh, Mahadevappa; Rajendran, Ramji R; Fishman, Elliot K
2017-05-01
RadiologyInfo.org is a public information portal designed to support patient care and broaden public awareness of the essential role radiology plays in overall patient health care. Over the past 14 years, RadiologyInfo.org has evolved considerably to provide access to more than 220 mixed-media descriptions of tests, treatments, and diseases through a spectrum of mobile and desktop platforms, social media, and downloadable documents in both English and Spanish. In 2014, the RSNA-ACR Public Information Website Committee, which stewards RadiologyInfo.org, developed 3- to 5-year strategic and implementation plans for the website. The process was informed by RadiologyInfo.org user surveys, formal stakeholder interviews, focus groups, and usability testing. Metrics were established as key performance indicators to assess progress toward the stated goals of (1) optimizing content to enhance patient-centeredness, (2) enhancing reach and engagement, and (3) maintaining sustainability. Major changes resulting from this process include a complete redesign of the website, the replacement of text-rich PowerPoint presentations with conversational videos, and the development of an affiliate network. Over the past year, visits to RadiologyInfo.org have increased by 60.27% to 1,424,523 in August 2016 from 235 countries and territories. Twenty-two organizations have affiliated with RadiologyInfo.org with new organizations being added on a monthly basis. RadiologyInfo provides a tangible demonstration of how radiologists can engage directly with the global public to educate them on the value of radiology in their health care and to allay concerns and dispel misconceptions. Regular self-assessment and responsive planning will ensure its continued growth and relevance. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Sessa, Maurizio; Rossi, Claudia; Mascolo, Annamaria; Grassi, Enrico; Fiorentino, Sonia; Scavone, Cristina; Reginelli, Alfonso; Rotondo, Antonio; Sportiello, Liberata
2015-01-01
During the last years in Italy, contrast media (CM) use increased. An increase of monitoring activities on CM-induced adverse drug reaction (ADR) is necessary, also in our regional territory. The main aim of this study was to give a preliminary evaluation of all Spontaneous Reports of ADRs (SRA) attributed to CM sent to Campania Pharmacovigilance Regional Center (CRFVC) from 01 January 2001 to 31 October 2014. For each SRA we evaluated: frequency and source, ADRs onset (time to event, seriousness and outcome), socio-demographic characteristics and risk factors of cases, the most reported CM (checking for pharmacodynamic and pharmacokinetic interactions). A total of 111 SRA were sent to CRFVC; specialist in radiology was the main source of reports. Ninety-seven SRA (87.3%) were referable to hypersensitivity reactions. Thirty-four SRA (30.6%) reported serious ADRs. The most reported CM were iopamidol, gadobenic acid and gadoteric acid. We identified two SRA induced by pharmacokinetic and/or pharmacodynamic interactions. During 14 years of post-marketing surveillance, only few SRA concerning CM-induced ADRs were sent to CRFVC probably due to underreporting. We aim to improve monitoring activity on CM-induced ADRs especially in hospitals. Most reported ADR and CM were in line with current body of literature.
Bonciarelli, Giorgio; Batacchi, Stefano; Biffi, Roberto; Buononato, Massimo; Damascelli, Bruno; Ghibaudo, Flavio; Orsi, Franco; Pittiruti, Mauro; Scoppettuolo, Giancarlo; Verzè, Alessia; Borasi, Guido; De Cicco, Marcello; Dosio, Roberto; Gazzo, Paolo; Maso, Renzo; Roman, Alessandro; Ticha, Vladimira; Venier, Giacomo; Blackburn, Paul; Goossens, Godelieve A; Bowen Santolucito, Jamie; Stas, Marguerite; Van Boxtel, Ton; Vesely, Thomas M; de Lutio, Enrico
2011-01-01
The use of totally implantable venous access devices in radiology may be associated with complications such as occlusion of the system (because of the high density of some contrast), infection (if the port is not handled in aseptic conditions, using proper barrier protections), and mechanical complications due to the high-pressure administration of contrast by automatic injectors (so-called power injector), including extravasation of contrast media into the soft tissues, subintimal venous or myocardial injection, or serious damage to the device itself (breakage of the external connections, dislocation of the non-coring needle, or breakage of the catheter). The last problem - i.e., the damage of the device from a power injection - is not an unjustified fear, but a reality. A warning by the US Food and Drug Administration of July 2004 reports around 250 complications of this kind, referring to both port and central venous catheters and peripherally inserted central catheter systems, which occurred over a period of several years; in all cases, the damage occurred during the injection of contrast material by means of power injectors for computed tomography or magnetic resonance imaging procedures. Though the risk associated with the use of ports in radiodiagnostics is thus clear, it has been suggested that administration of the contrast material via the port may have some advantage in terms of image quality, increased comfort for the patient, and maybe more accurate reproducibility of the patient's own follow-up exams. This contention needs to be supported by evidence. Also, since many cancer patients who need frequent computed tomography studies already have totally implantable systems, it would seem reasonable to try to define how and when such systems may safely be used. The purpose of this consensus statement is to define recommendations based on the best available evidence, for the safe use of implantable ports in radiodiagnostics.
[Hypersensitivity reaction to radio contrast media: diagnosis, prevention and treatment].
Mahlab-Guri, Keren; Herskovitz, Pearl; Sthoeger, Zev
2012-07-01
More than 70 million radiographic examinations with radio contrast media are performed worldwide each year. The incidence of adverse reactions to radio contrast media is 5-13%. Adverse reactions include hypersensitivity reactions, chemotoxic reactions and renal toxicity. Hypersensitivity reactions to radio contrast media range from mild pruritus to life-threatening emergency. The differential diagnosis between hypersensitivity reaction to radio contrast media and chemotoxic reaction is challenging. The incidence of chemotoxic reactions is mainly affected by the chemical structure of the radio contrast media and the rate of infusion. The incidence of hypersensitivity radio contrast media reaction is affected by age and by the presence of asthma and other atopic diseases. The diagnosis of hypersensitivity reaction to radio contrast media is based on clinical manifestations. The additional value of laboratory tests is limited and questionable. In case of hypersensitivity radio contrast reaction, the infusion should be stopped immediately, airways should be protected and fluids, oxygen and drugs should be given. Prophylactic treatment before its administration may prevent hypersensitivity reactions to radio contrast media.
Swanson, Jonathan O; Levine, Marc S; Redfern, Regina O; Rubesin, Stephen E
2003-08-01
The purpose of this study was to determine the usefulness of a high-density (250% weight/volume) barium compared with a water-soluble contrast agent for the detection of esophageal leaks in patients who had undergone esophagogastrectomy, total gastrectomy, or total laryngectomy. A search of our radiology database from 1998 to 2001 revealed 46 eligible radiographic studies performed using a water-soluble contrast agent alone or a water-soluble contrast agent followed by barium that showed leaks in patients who had undergone esophagogastrectomy, total gastrectomy, or total laryngectomy. The images were reviewed to determine the morphology of the leaks (i.e., blind-ending tracks, sealed-off collections, or free extravasation of contrast material). Medical records were also reviewed to determine whether detection of the leaks seen on the radiographic studies affected patient management. Of the 46 leaks seen on radiographic studies, 23 (50%) were detected with a water-soluble contrast agent and 23 (50%) were detected only with high-density barium. Of the 23 leaks visualized with water-soluble contrast media, six (26%) were characterized by blind-ending tracks, 14 (61%) by sealed-off collections, and three (13%) by free extravasation of contrast material into the mediastinum or neck. Of the 23 leaks visualized only with high-density barium, 19 (83%) were characterized by blind-ending tracks and four (17%) by sealed-off collections. Thus, leaks detected only on images obtained with high-density barium were significantly more likely to be characterized by blind-ending tracks than those detected on images obtained with a water-soluble contrast agent (p = 0.0007). Of the 33 patients with clinical follow-up, the findings seen on these imaging studies affected management in 12 (86%) of 14 patients with leaks depicted by water-soluble contrast media and in 10 (53%) of 19 with leaks depicted only by high-density barium. Our findings support the use of high-density barium as part of the routine postoperative radiographic examination when no leaks are detected on images obtained with a water-soluble contrast agent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Semple, Scott; Harry, Vanessa N. MRCOG.; Parkin, David E.
2009-10-01
Purpose: To investigate the combination of pharmacokinetic and radiologic assessment of dynamic contrast-enhanced magnetic resonance imaging (MRI) as an early response indicator in women receiving chemoradiation for advanced cervical cancer. Methods and Materials: Twenty women with locally advanced cervical cancer were included in a prospective cohort study. Dynamic contrast-enhanced MRI was carried out before chemoradiation, after 2 weeks of therapy, and at the conclusion of therapy using a 1.5-T MRI scanner. Radiologic assessment of uptake parameters was obtained from resultant intensity curves. Pharmacokinetic analysis using a multicompartment model was also performed. General linear modeling was used to combine radiologic andmore » pharmacokinetic parameters and correlated with eventual response as determined by change in MRI tumor size and conventional clinical response. A subgroup of 11 women underwent repeat pretherapy MRI to test pharmacokinetic reproducibility. Results: Pretherapy radiologic parameters and pharmacokinetic K{sup trans} correlated with response (p < 0.01). General linear modeling demonstrated that a combination of radiologic and pharmacokinetic assessments before therapy was able to predict more than 88% of variance of response. Reproducibility of pharmacokinetic modeling was confirmed. Conclusions: A combination of radiologic assessment with pharmacokinetic modeling applied to dynamic MRI before the start of chemoradiation improves the predictive power of either by more than 20%. The potential improvements in therapy response prediction using this type of combined analysis of dynamic contrast-enhanced MRI may aid in the development of more individualized, effective therapy regimens for this patient group.« less
Renal excretion of water-soluble contrast media after enema in the neonatal period.
Kim, Hee Sun; Je, Bo-Kyung; Cha, Sang Hoon; Choi, Byung Min; Lee, Ki Yeol; Lee, Seung Hwa
2014-08-01
When abdominal distention occurs or bowel obstruction is suspected in the neonatal period, a water-soluble contrast enema is helpful for diagnostic and therapeutic purposes. The water-soluble contrast medium is evacuated through the anus as well as excreted via the kidneys in some babies. This study was designed to evaluate the incidence of renal excretion after enemas using water-soluble contrast media and presume the causes. Contrast enemas using diluted water-soluble contrast media were performed in 23 patients under 2 months of age. After the enema, patients were followed with simple abdominal radiographs to assess the improvement in bowel distention, and we could also detect the presence of renal excretion of contrast media on the radiographs. Reviewing the medical records and imaging studies, including enemas and consecutive abdominal radiographs, we evaluated the incidence of renal excretion of water-soluble contrast media and counted the stay duration of contrast media in urinary tract, bladder, and colon. Among 23 patients, 12 patients (52%) experienced the renal excretion of water-soluble contrast media. In these patients, stay-in-bladder durations of contrast media were 1-3 days and stay-in-colon durations of contrast media were 1-10 days, while stay-in-colon durations of contrast media were 1-3 days in the patients not showing renal excretion of contrast media. The Mann-Whitney test for stay-in-colon durations demonstrated the later evacuation of contrast media in the patients with renal excretion of contrast media (p = 0.07). The review of the medical records showed that 19 patients were finally diagnosed as intestinal diseases, including Hirschsprung's disease, meconium ileum, meconium plug syndrome, and small bowel atresia or stenosis. Fisher's exact test between the presence of urinary excretion and intestinal diseases indicated a statistically significant difference (p = 0.04). The intestinal diseases causing bowel obstruction may increase the water-soluble contrast media's dwell time in the bowel and also increase urinary excretion. Copyright © 2013. Published by Elsevier B.V.
The Use of Twitter by Radiology Journals: An Analysis of Twitter Activity and Impact Factor.
Kelly, Brendan S; Redmond, Ciaran E; Nason, Gregory J; Healy, Gerard M; Horgan, Niall A; Heffernan, Eric J
2016-11-01
Medical journals use social media as a means to disseminate new research and interact with readers. The microblogging site Twitter is one such platform. The aim of this study was to analyze the recent use of Twitter by the leading radiology journals. The top 50 journals by Impact Factor were included. Twitter profiles associated with these journals, or their corresponding societies, were identified. Whether each journal used other social media platforms was also recorded. Each Twitter profile was analyzed over a one-year period, with data collected via Twitonomy software. Klout scores of social media influence were calculated. Results were analyzed in SPSS using Student's t test, Fisher contingency tables, and Pearson correlations to identify any association between social media interaction and Impact Factors of journals. Fourteen journals (28%) had dedicated Twitter profiles. Of the 36 journals without dedicated Twitter profiles, 25 (50%) were associated with societies that had profiles, leaving 11 (22%) journals without a presence on Twitter. The mean Impact Factor of all journals was 3.1 ± 1.41 (range, 1.7-6.9). Journals with Twitter profiles had higher Impact Factors than those without (mean, 3.37 vs 2.14; P < .001). There was no statistically significant difference between the Impact Factors of the journals with dedicated Twitter profiles and those associated with affiliated societies (P = .47). Since joining Twitter, 7 of the 11 journals (64%) experienced increases in Impact Factor. A greater number of Twitter followers was correlated with higher journal Impact Factor (R 2 = 0.581, P = .029). The investigators assessed the prevalence and activity of the leading radiology journals on Twitter. Radiology journals with Twitter profiles have higher Impact Factors than those without profiles, and the number of followers of a journal's Twitter profile is positively associated with Impact Factor. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Macis, Giuseppe; Di Giovanni, Silvia; Di Franco, Davide; Bonomo, Lorenzo
2013-01-01
The future approach of diagnostic imaging in urology follows the technological progress, which made the visualization of in vivo molecular processes possible. From anatomo-morphological diagnostic imaging and through functional imaging molecular radiology is reached. Based on molecular probes, imaging is aimed at assessing the in vivo molecular processes, their physiology and function at cellular level. The future imaging will investigate the complex tumor functioning as metabolism, aerobic glycolysis in particular, angiogenesis, cell proliferation, metastatic potential, hypoxia, apoptosis and receptors expressed by neoplastic cells. Methods for performing molecular radiology are CT, MRI, PET-CT, PET-MRI, SPECT and optical imaging. Molecular ultrasound combines technological advancement with targeted contrast media based on microbubbles, this allowing the selective registration of microbubble signal while that of stationary tissues is suppressed. An experimental study was carried out where the ultrasound molecular probe BR55 strictly bound to prostate tumor results in strong enhancement in the early phase after contrast, this contrast being maintained in the late phase. This late enhancement is markedly significant for the detection of prostatic cancer foci and to guide the biopsy sampling. The 124I-cG250 molecular antibody which is strictly linked to cellular carbonic anhydrase IX of clear cell renal carcinoma, allows the acquisition of diagnostic PET images of clear cell renal carcinoma without biopsy. This WG-250 (RENCAREX) antibody was used as a therapy in metastatic clear cell renal carcinoma. Future advancements and applications will result in early cancer diagnosis, personalized therapy that will be specific according to the molecular features of cancer and leading to the development of catheter-based multichannel molecular imaging devices for cystoscopy-based molecular imaging diagnosis and intervention.
Leveraging Twitter to Maximize the Radiology Meeting Experience.
Kalia, Vivek; Ortiz, Daniel A; Patel, Amy K; Moriarity, Andrew K; Canon, Cheri L; Duszak, Richard
2018-01-01
Over recent years, social media engagement has proliferated among physicians, health care systems, scientific journals, professional societies, and patients. In radiology, Twitter (Twitter Inc, San Francisco, California) has rapidly become the preferred social media engagement tool and is now an essential activity at many large radiology society meetings. Twitter offers a versatile, albeit simple, platform for anyone interested in engaging with others, regardless of title, stature, or geography. In radiology and other medical specialties, year-after-year increases in Twitter engagement before, during, and after professional society meetings continue with widespread positive feedback. This short-form messaging tool also allows users to connect and interact with high-impact individuals and organizations on an ongoing basis (rather than once a year during large meetings). Through live-polling, Twitter also has the power to gather global opinions on issues highly relevant to radiology's future, such as the Medicare Access and CHIP Reauthorization Act of 2015 (MACRA) or breast cancer screening. Also increasingly popular is "live-tweeting" of curated meeting content, which makes information from the meeting accessible to a global audience. Despite the promise of growing professional networks and enabling discussions that cross geographic boundaries, the risks of Twitter use during radiology meetings must be recognized and mitigated. These include posting of unpublished data without consent (eg, slide content captured on camera phones), propagation of misinformation, and copyright infringement. Despite these issues and with an eye towards professionalism, Twitter can nonetheless be used effectively to increase engagement among radiologists, radiology societies, and patients. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Anderson, Stephan W; Soto, Jorge A; Lucey, Brian C; Ozonoff, Al; Jordan, Jacqueline D; Ratevosian, Jirair; Ulrich, Andrew S; Rathlev, Niels K; Mitchell, Patricia M; Rebholz, Casey; Feldman, James A; Rhea, James T
2009-11-01
The objective of our study was to compare the diagnostic accuracy of IV contrast-enhanced 64-MDCT with and without the use of oral contrast material in diagnosing appendicitis in patients with abdominal pain. We conducted a randomized trial of a convenience sample of adult patients presenting to an urban academic emergency department with acute nontraumatic abdominal pain and clinical suspicion of appendicitis, diverticulitis, or small-bowel obstruction. Patients were enrolled between 8 am and 11 pm when research assistants were present. Consenting subjects were randomized into one of two groups: Group 1 subjects underwent 64-MDCT performed with oral and IV contrast media and group 2 subjects underwent 64-MDCT performed solely with IV contrast material. Three expert radiologists independently reviewed the CT examinations, evaluating for the presence of appendicitis. Each radiologist interpreted 202 examinations, ensuring that each examination was interpreted by two radiologists. Individual reader performance and a combined interpretation performance of the two readers assigned to each case were calculated. In cases of disagreement, the third reader was asked to deliver a tiebreaker interpretation to be used to calculate the combined reader performance. Final outcome was based on operative, clinical, and follow-up data. We compared radiologic diagnoses with clinical outcomes to calculate the diagnostic accuracy of CT in both groups. Of the 303 patients enrolled, 151 patients (50%) were randomized to group 1 and the remaining 152 (50%) were randomized to group 2. The combined reader performance for the diagnosis of appendicitis in group 1 was a sensitivity of 100% (95% CI, 76.8-100%) and specificity of 97.1% (95% CI, 92.7-99.2%). The performance in group 2 was a sensitivity of 100% (73.5-100%) and specificity of 97.1% (92.9-99.2%). Patients presenting with nontraumatic abdominal pain imaged using 64-MDCT with isotropic reformations had similar characteristics for the diagnosis of appendicitis when IV contrast material alone was used and when oral and IV contrast media were used.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Royon, Laurent; Marcy, Pierre Yves; Merckx, Jacques
2013-01-01
The use of totally implantable venous access devices (TIVADs) certified as "high pressure resistant" or "power port" has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter? The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on. We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Royon, Laurent; Marcy, Pierre Yves; Merckx, Jacques
2013-01-01
Purpose The use of totally implantable venous access devices (TIVADs) certified as “high pressure resistant” or “power port” has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter? Results The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on. Conclusion We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice. PMID:24043959
NASA Astrophysics Data System (ADS)
Lo, Ching-Jung; Yang, Pei-Ying; Chao, Tsi-Chian; Tu, Shu-Ju
2015-06-01
In the treatment planning of radiation therapy, patients may be administrated with contrast media in CT scanning to assist physicians for accurate delineation of the target or organs. However, contrast media are not used in patients during the treatment delivery. In particular, contrast media contain materials with high atomic numbers and dosimetric variations may occur between scenarios where contrast media are present in treatment planning and absent in treatment delivery. In this study we evaluate the effect of contrast media on the dosimetry and biological consequence. An analytical phantom based on AAPM TG 119 and five sets of CT images from clinical patients are included. Different techniques of treatment planning are considered, including 1-field AP, 2-field AP+PA, 4-field box, 7-field IMRT, and RapidArc. RapidArc is a recent technique of volumetric modulated arc therapy and is used in our study of contrast media in clinical scenarios. The effect of RapidArc on dosimetry and biological consequence for administration of contrast media in radiotherapy is not discussed previously in literature. It is shown that dose difference is reduced as the number of external beams is increased, suggesting RapidArc may be favored to be used in the treatment planning enhanced by contrast media. Linear trend lines are fitted for assessment of percent dose differences in the planning target volume versus concentrations of contrast media between plans where contrast media are present and absent, respectively.
Tsuji, Shintaro; Fukuda, Akihisa; Yagahara, Ayako; Nishimoto, Naoki; Homma, Katsumi; Ogasawara, Katsuhiko
2015-03-01
In 1994, Japanese Society of Radiological Technology (JSRT) constructed the lexicon in the field of radiologic technology. However, recently, latest lexicon is not updated yet. The purpose of this article is to compare the terminologies in clinical medicine with the others and to consider reconstructing the lexicon in the radiological technology. Our study selected three categories from the database of the academic society. These three groups were Clinical medicine (hereafter CM, 167 societies, includes JSRT), Psychology / Education (hereafter P/E, 104 societies), and Comprehensive synthetic engineering (hereafter CSE, 40 societies). First, all societies were surveyed to know whether there were any lexicon in their official website. Second, these terminologies were surveyed on the following criteria: (a) Media of lexicon, (b) Number of terms, (c) File type of lexicon, (d) Terms translated into English, (e) Way of searching terms, and (f) Number of committees of the terminology. Lexicon in CM, P/E, and CSE had 20, 4, and 7. Compared with P/E and CSE, CM showed the following trends: (a) used electronic media frequently, (b) stored large number of terms (about 5,000 to 11,000), (c) enabled to download frequently, and (d) used the alphabet and Japanese syllabary order frequently. Compared with the lexicon of P/E and CSE, terminology in CM tended to adopt the electronic media of lexicon and to have large number of terms. Additionally, many lexicons were expressed in English terms along with Japanese terms. Following massive lexicon of SNOMED-CT and RadLex, it is necessary to consider applying the web-based term searching and an ontological technique to the lexicon of radiological technology.
Indications and radiological findings of acute otitis media and its complications.
Pont, Elena; Mazón, Miguel
Most cases of acute otitis media resolve with antibiotics and imaging is not required. When treatment fails or a complication is suspected, imaging plays a crucial role. Since the introduction of antibiotic treatment, the complication rate has decreased dramatically. Nevertheless, given the critical clinical relevance of complications, the importance of early diagnosis is vital. Our objective was to review the clinical and radiological features of acute otitis media and its complications. They were classified based on their location, as intratemporal or intracranial. Imaging makes it possible to diagnose the complications of acute otitis media and to institute appropriate treatment. Computed tomography is the initial technique of choice and, in most cases, the ultimate. Magnetic resonance is useful for evaluating the inner ear and when accurate evaluation of disease extent or better characterization of intracranial complications is required. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.
Hemodynamic and tubular changes induced by contrast media.
Caiazza, Antonella; Russo, Luigi; Sabbatini, Massimo; Russo, Domenico
2014-01-01
The incidence of acute kidney injury induced by contrast media (CI-AKI) is the third cause of AKI in hospitalized patients. Contrast media cause relevant alterations both in renal hemodynamics and in renal tubular cell function that lead to CI-AKI. The vasoconstriction of intrarenal vasculature is the main hemodynamic change induced by contrast media; the vasoconstriction is accompanied by a cascade of events leading to ischemia and reduction of glomerular filtration rate. Cytotoxicity of contrast media causes apoptosis of tubular cells with consequent formation of casts and worsening of ischemia. There is an interplay between the negative effects of contrast media on renal hemodynamics and on tubular cell function that leads to activation of renin-angiotensin system and increased production of reactive oxygen species (ROS) within the kidney. Production of ROS intensifies cellular hypoxia through endothelial dysfunction and alteration of mechanisms regulating tubular cells transport. The physiochemical characteristics of contrast media play a critical role in the incidence of CI-AKI. Guidelines suggest the use of either isoosmolar or low-osmolar contrast media rather than high-osmolar contrast media particularly in patients at increased risk of CI-AKI. Older age, presence of atherosclerosis, congestive heart failure, chronic renal disease, nephrotoxic drugs, and diuretics may multiply the risk of CI-AKI.
Hemodynamic and Tubular Changes Induced by Contrast Media
Caiazza, Antonella; Russo, Luigi; Russo, Domenico
2014-01-01
The incidence of acute kidney injury induced by contrast media (CI-AKI) is the third cause of AKI in hospitalized patients. Contrast media cause relevant alterations both in renal hemodynamics and in renal tubular cell function that lead to CI-AKI. The vasoconstriction of intrarenal vasculature is the main hemodynamic change induced by contrast media; the vasoconstriction is accompanied by a cascade of events leading to ischemia and reduction of glomerular filtration rate. Cytotoxicity of contrast media causes apoptosis of tubular cells with consequent formation of casts and worsening of ischemia. There is an interplay between the negative effects of contrast media on renal hemodynamics and on tubular cell function that leads to activation of renin-angiotensin system and increased production of reactive oxygen species (ROS) within the kidney. Production of ROS intensifies cellular hypoxia through endothelial dysfunction and alteration of mechanisms regulating tubular cells transport. The physiochemical characteristics of contrast media play a critical role in the incidence of CI-AKI. Guidelines suggest the use of either isoosmolar or low-osmolar contrast media rather than high-osmolar contrast media particularly in patients at increased risk of CI-AKI. Older age, presence of atherosclerosis, congestive heart failure, chronic renal disease, nephrotoxic drugs, and diuretics may multiply the risk of CI-AKI. PMID:24678510
Fröhlich, J M; Kubik-Huch, R A
2013-01-01
The use and the safety of radiographic, MR- or ultrasound contrast media in the diagnostic work-up of pregnant or lactating patients is a frequently discussed question. As only sparse clinical data is available, a careful benefit-risk assessment must contain physico-chemical properties, preclinical data including teratogeneity and embryotoxicity, as well as maternal and foetal exposure. With consideration to the individual risks, iodinated contrast media, macrocyclic MR contrast media with increased stability or sulphur hexafluoride ultrasound contrast media may, if clinically justified, be administered in the smallest possible doses throughout pregnancy. After parental administration of an iodinated contrast medium after the 12th week of pregnancy, the neonate's thyroidal function should be checked during the first week after birth. After parental administration of iodinated, stable macrocyclic, gadolinium or ultrasound contrast media, lactation can be continued normally. In any case, contrast media should be used with caution and only if the benefits outweigh the risk. © Georg Thieme Verlag KG Stuttgart · New York.
Jinzaki, Masahiro; Kitagawa, Kakuya; Tsai, I-Chen; Chan, Carmen; Yu, Wei; Yong, Hwan Seok; Choi, Byoung Wook
2010-12-01
The use of contrast media for cardiac imaging becomes increasing as the widespread of cardiac CT and cardiac MR. A radiologist needs to carefully consider the indication and the injection protocol of contrast media to be used as well as the possibility of adverse effect. There are several guidelines for contrast media in western countries. However, these are focusing the adverse effect of contrast media. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and created a guideline, which summarizes the integrated knowledge of contrast media for cardiac imaging. In cardiac imaging, coronary artery evaluation is feasible by non-contrast MR angiography, which can be an alternative examination in high risk patients for the use of iodine contrast media. Furthermore, the body habitus of Asian patients is usually smaller than that of their western counterparts. This necessitates modifications in the injection protocol and in the formula for calculation of estimated glomerular filtration rate. This guideline provided fundamental information for the use of contrast media for Asian patients in cardiac imaging.
Kitagawa, Kakuya; Tsai, I-Chen; Chan, Carmen; Yu, Wei; Yong, Hwan Seok; Choi, Byoung Wook
2010-01-01
The use of contrast media for cardiac imaging becomes increasing as the widespread of cardiac CT and cardiac MR. A radiologist needs to carefully consider the indication and the injection protocol of contrast media to be used as well as the possibility of adverse effect. There are several guidelines for contrast media in western countries. However, these are focusing the adverse effect of contrast media. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and created a guideline, which summarizes the integrated knowledge of contrast media for cardiac imaging. In cardiac imaging, coronary artery evaluation is feasible by non-contrast MR angiography, which can be an alternative examination in high risk patients for the use of iodine contrast media. Furthermore, the body habitus of Asian patients is usually smaller than that of their western counterparts. This necessitates modifications in the injection protocol and in the formula for calculation of estimated glomerular filtration rate. This guideline provided fundamental information for the use of contrast media for Asian patients in cardiac imaging. PMID:20931289
Nelson, B B; Goodrich, L R; Barrett, M F; Grinstaff, M W; Kawcak, C E
2017-07-01
The use of contrast media in computed tomography (CT) and magnetic resonance imaging (MRI) is increasing in horses. These contrast-enhanced imaging techniques provide improved tissue delineation and evaluation, thereby expanding diagnostic capabilities. While generally considered safe, not all contrast media exhibit the same safety profiles. The safety of contrast media use and descriptions of adverse events occurring in horses are sparsely reported. This review summarises the reported evidence of contrast media use and adverse events that occur in horses, with added contribution from other veterinary species and studies in man for comparison. This comprehensive data set empowers equine clinicians to develop use and monitoring strategies when working with contrast media. Finally, it summarises the current state-of-the-art and highlights the potential applications of contrast-enhanced CT and MRI for assessment of diseased or injured equine tissues, as well as (patho)physiological processes. © 2017 EVJ Ltd.
2014-01-01
Background Contrast-induced acute kidney injury is a common cause of iatrogenic acute kidney injury (AKI). Most of the published estimates of AKI after contrast use originate from the cardiac catheterization literature despite contrast-enhanced computed tomography (CT) scans being the more common setting for contrast use. This systematic review aims to summarize the current evidence about (1)the risk of AKI following intravenous (IV) contrast-enhanced CT scans and(2) the risk of clinical outcomes (i.e. death, hospitalization and need for renal replacement therapy) due to IV contrast-enhanced CT scans. Methods/Design A systematic literature search for published studies will be performed using MEDLINE, EMBASE and The COCHRANE Library databases. Unpublished studies will be identified by searching through grey literature. No language restriction will be applied. The review will consider all studies that have examined the association between IV contrast media and AKI. To be selected, the study should include two arms: one group of exposed patients who received IV contrast material before CT scans and one group of unexposed group who did not receive contrast material before CT scans. Two authors will independently screen titles and abstracts obtained from electronic databases, extract data and will assess the quality of the studies selected using the Cochrane's ‘Risk of Bias’ assessment tool for randomized trials and the Newcastle-Ottawa Scale for observational studies. A random-effects meta-analysis will be performed if there is no remarkable heterogeneity between studies. Discussion This systematic review will provide synthesis of current evidence around the effect of IV contrast material on AKI and other clinical outcomes. Results will be helpful for making evidence-based recommendations and guidelines for clinical and radiologic settings. Systematic review registration PROSPERO CRD42013003799. PMID:25148933
The Strategic Imperative for the Use of Social Media in Health Care.
Kotsenas, Amy L; Arce, Makala; Aase, Lee; Timimi, Farris K; Young, Colleen; Wald, John T
2018-01-01
Although health care lags behind many other industries in adopting social media as part of a business strategy, the Mayo Clinic recognized the importance of these applications more than a decade ago. In addition to typical media relations and marketing tactics, the Mayo Clinic has successfully used social media as part of an overall program to support the strategic imperatives of the institution. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Instagram as a Vehicle for Education: What Radiology Educators Need to Know.
Shafer, Serena; Johnson, Michael B; Thomas, Rachel B; Johnson, Pamela T; Fishman, Elliot K
2018-06-01
Since its inception in 2010, Instagram has rapidly grown into one of the world's largest social media forums, with over 700 million registered users. In the field of medicine, Instagram has been used for professional development and is also being added to the armamentarium of social media vehicles for education. Utilization of Instagram for medical education lags behind Facebook and Twitter, as many educators may not recognize the potential role. The purpose of this manuscript is to describe unique features of Instagram that are not found on Facebook and Twitter, with the aim of facilitating use of Instagram for radiology education. Copyright © 2018. Published by Elsevier Inc.
Hawkins, C Matthew; Duszak, Richard; Rawson, James V
2014-04-01
Twitter is a social media microblogging platform that allows rapid exchange of information between individuals. Despite its widespread acceptance and use at various other medical specialty meetings, there are no published data evaluating its use at radiology meetings. The purpose of this study is to quantitatively and qualitatively evaluate the use of Twitter as a microblogging platform at recent RSNA annual meetings. Twitter activity meta-data tagged with official meeting hashtags #RSNA11 and #RSNA12 were collected and analyzed. Multiple metrics were evaluated, including daily and hourly Twitter activity, frequency of microblogging activity over time, characteristics of the 100 most active Twitter users at each meeting, characteristics of meeting-related tweets, and the geographic origin of meeting microbloggers. The use of Twitter microblogging increased by at least 30% by all identifiable meaningful metrics between the 2011 and 2012 RSNA annual meetings, including total tweets, tweets per day, activity of the most active microbloggers, and total number of microbloggers. Similar increases were observed in numbers of North American and international microbloggers. Markedly increased use of the Twitter microblogging platform at recent RSNA annual meetings demonstrates the potential to leverage this technology to engage meeting attendees, improve scientific sessions, and promote improved collaboration at national radiology meetings. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Computed tomographic contrast tenography of the digital flexor tendon sheath of the equine hindlimb.
Agass, Rachel; Dixon, Jonathon; Fraser, Barny
2018-05-01
Pre-surgical investigation of digital flexor tendon sheath pathology remains challenging with current standard imaging techniques. The aim of this prospective, anatomical, pilot study was to describe the anatomy of the equine hind limb digital flexor tendon sheath using a combination of computed tomography (CT) and computed tomographic contrast tenography in clinically normal cadaver limbs. Ten pairs of hind limbs with no external abnormalities were examined from the level of the tarsometatarsal joint distally. Limbs initially underwent non-contrast CT examination using 120 kVp, 300 mAs, and 1.5 mm slice thickness. Sixty millilitres of ioversol iodinated contrast media and saline (final concentration 100 mg/ml) were injected using a basilar sesamoidean approach. The computed tomographic contrast tenography examination was then repeated, before dissection of the specimens to compare gross and imaging findings. The combined CT and computed tomographic contrast tenography examinations provided excellent anatomical detail of intra-thecal structures. The borders of the superficial and deep digital flexor tendons, and the manica flexoria were consistently identifiable in all limbs. Detailed anatomy including that of the mesotenons, two of which are previously undescribed, and the plantar annular ligament were also consistently identifiable. Dissection of all 10 pairs of limbs revealed there to be no pathology, in accordance with the imaging findings. In conclusion, the combination of CT and computed tomographic contrast tenography may be useful adjunctive diagnostic techniques to define digital flexor tendon sheath pathology prior to surgical exploration in horses. © 2017 American College of Veterinary Radiology.
İmamoğlu, Hakan; Doğan, Serap; Erdoğan, Nuri
2018-02-01
The aim of this study was to investigate the tendency of referring physicians to collaborate with radiologists in managing contrast media (CM)-related risk factors. The study was conducted at a single academic hospital. Among 150 referring physicians from various specialties, 51 referring physicians (34%) responded to the invitation letter asking for an interview with a radiologist. During the interview, a modified form of the Control Preferences Scale was administered, in which there were five preferences (each displayed on a separate card) that ranged from the fully active to fully passive involvement of referring physicians in managing CM-related risk factors. A descriptive analysis was performed through categorization of the results depending on the respondents' two most preferred roles. Thirty-six referring physicians (70.5%) preferred a collaborative role, and 15 (29.4%) preferred a noncollaborative role (i.e., remained on either the fully active or fully passive side). Among the referring physicians who preferred a collaborative role, the most common response (n = 15 [29.4%]) was collaborative-active. Referring physicians at the authors' institution have basic cognitive and motivational-affective tone toward collaboration in future teamwork aimed at the management of CM-related risk factors. A modified form of the Control Preferences Scale, as in this study, can be used to investigate the tendency of referring physicians to collaborate with radiologists. The results are discussed from ethical and legal perspectives. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Ahn, Young-Hwan; Koh, Young-Il; Kim, Joo-Hee; Ban, Ga-Young; Lee, Yeon-Kyung; Hong, Ga-Na; Jin, U-Ram; Choi, Byung-Joo; Shin, Yoo-Seob; Park, Hae-Sim; Ye, Young-Min
2015-03-01
Both immediate and delayed hypersensitivity reactions to iodinated contrast media (ICM) are relatively common. However, there are few data to determine the clinical utility of immunologic evaluation of ICM. To evaluate the utility of ICM skin testing in patients with ICM hypersensitivity, 23 patients (17 immediate and 6 delayed reactions) were enrolled from 3 university hospitals in Korea. With 6 commonly used ICM including iopromide, iohexol, ioversol, iomeprol, iopamidol and iodixanol, skin prick (SPT), intradermal (IDT) and patch tests were performed. Of 10 patients with anaphylaxis, 3 (30.0%) and 6 (60.0%) were positive respectively on SPTs and IDTs with the culprit ICM. Three of 6 patients with urticaria showed positive IDTs. In total, 11 (64.7%) had positive on either SPT or IDT. Three of 6 patients with delayed rashes had positive response to patch test and/or delayed IDT. Among 5 patients (3 anaphylaxis, 1 urticaria and 1 delayed rash) taken subsequent radiological examinations, 3 patients administered safe alternatives according to the results of skin testing had no adverse reaction. However, anaphylaxis developed in the other 2 patients administered the culprit ICM again. With 64.7% (11/17) and 50% (3/6) of the sensitivities of corresponding allergic skin tests with culprit ICM for immediate and delayed hypersensitivity reactions, the present study suggests that skin tests is useful for the diagnosis of ICM hypersensitivity and for selecting safe ICM and preventing a recurrence of anaphylaxis caused by the same ICM.
Reilly, Frank; Burke, John P; Appelmans, Eline; Manzoor, Talha; Deasy, Joseph; McNamara, Deborah A
2014-04-01
Anastomotic leak (AL) is a major complication following anterior resection for colorectal cancer. Early contrast enema may diagnose subclinical anastomotic leakage. Knowledge of factors concerning AL is vital to its detection. The aim of this study was to define the incidence, risks and outcome of radiological leak following routine early contrast enema after anterior resection. A cohort of 129 patients who underwent anterior resection for colorectal cancer and had an early Gastrografin enema between July 2008 and December 2012 in a tertiary referral centre was identified from a prospective database. The severity of AL was defined using the International Study Group of Rectal Cancer (ISREC) grading system. Of the 129 patients, 65.1 % were male, and the mean age at surgery was 64.6 ± 1.1 years. Gastrografin enema was performed on average on post-operative day 4.8 ± 0.2. Eighteen patients (14.0 %) had a radiological leak on Gastrografin enema, and nine patients (7.0 %) had a clinical AL. On multivariate analysis, only being of male sex and having a loop ileostomy increased the risk of radiological AL. Gastrografin enema had a sensitivity of 100 % (95 % CI 66-100 %) and specificity of 93 % (95 % CI 86-97 %) for predicting clinical AL. Of the 18 patients with radiological leaks, 11 were ISREC grade A, 3 were grade B and 4 were grade C. In the current series, early Gastrografin enema following anterior resection identifies a 14 % radiological leak rate and has a high sensitivity and specificity for predicting clinical AL. The majority of radiological leaks may be managed conservatively.
Niv, Galia; Costa, Matthew; Kicak, Patricia; Richman, Katherine
2014-06-01
Extravasation is a well-recognized complication estimated to be between 0.1% and 0.9% of contrast medium administrations. According to the UC San Diego (UCSD) health system policy, all contrast medium extravasation (CME) reports are reviewed by the department of Risk Management, and the appropriate action is taken. Despite this strategy, a decrease in the incidence of CME could not be demonstrated. The aims of this study were to determine the frequency, management, and outcome of CME in UC San Diego patients and to assess the knowledge regarding CME among radiology technologists based on policy and guidelines. The secondary aim was to assess the manual ability of the radiology technologists in the performance of the procedure. The study has 2 parts; the first was retrospective, including data collection and interpretation of all radiology procedures using intravenous contrast medium injection between January 1, 2010, and September 30, 2011, and the second was prospective, including proactive observations and knowledge questionnaire. There were 83 (0.48%) cases of CME of 17,200 patients, 54 women (0.64%) and 29 men (0.33%), P = 0.005. The patients with CME were older, and their cannula was inserted in other departments than Radiology Department, P < 0.000. There was a gap between the high theoretical knowledge that was found in the knowledge questionnaire and its implementation that was demonstrated in the proactive observation. Our data demonstrate that sex, age, and where the cannula was inserted are predictive factors for CME. We believe that CME could be prevented by proper educational program and establishment of efficient strategy.
Correlation Between Bile Reflux Gastritis and Biliary Excreted Contrast Media in the Stomach.
Hyun, Jong Jin; Yeom, Suk Keu; Shim, Euddeum; Cha, Jaehyung; Choi, Inyoung; Lee, Seung Hwa; Chung, Hwan Hoon; Cha, Sang Hoon; Lee, Chang Hee
This study aimed to evaluate the relationship between biliary excreted contrast media in the stomach and the presence of bile reflux gastritis. Consecutive 111 patients who underwent both gadoxetic acid-enhanced magnetic resonance cholangiography (gadoxetic MRC) and gastric endoscopy were included in this study. We performed a review of the gadoxetic-MRC image sets acquired 60 minutes after intravenous injection of contrast media and endoscopic images. We recorded amount of contrast media in the stomach. The sensitivity, specificity, and accuracy of duodenogastric bile reflux diagnosis were evaluated for the gadoxetic MRC. Statistical analysis was performed using the Fisher exact test and the linear-by-linear association test. Among the 111 patients, 39 had 60-minute delayed images showing the presence of contrast media in the stomach. Of these 39 patients, 13 had bile reflux gastritis and 5 showed bile in the stomach without evidence of erythematous gastritis. Of the 72 patients who did not show contrast media in the stomach, none had bile reflux gastritis and 2 patients showed bile staining in the stomach without evidence of erythematous gastritis. Bile reflux gastritis was significantly more frequent in patients with contrast media in the stomach on gadoxetic MRC than in those without. Patients with high-grade extension of contrast media in the stomach had significantly frequent bile reflux gastritis than did those with low-grade extension. Biliary excreted contrast media in the stomach on 60-minute delayed gadoxetic MRC has a correlation with the presence of bile reflux gastritis on endoscopic examination.
Diagnosis of cystocele--the correlation between clinical and radiological evaluation.
Altman, Daniel; Mellgren, Anders; Kierkegaard, Jonas; Zetterström, Jan; Falconer, Christian; López, Annika
2004-01-01
In patients with genital prolapse involving several compartments simultaneously, radiologic investigation can be used to complement the clinical assessment. Contrast medium in the urinary bladder enables visualization of the bladder base at cystodefecoperitoneography (CDP). The aim of the present study was to evaluate the correlation between clinical examination using the Pelvic Organ Prolapse Quantification system (POP-Q) and CDP. Thirty-three women underwent clinical assessment and CDP. Statistical analysis using Pearson's correlation coefficient ( r) demonstrated a wide variability between the current definition of cystocele at CDP and POP-Q ( r=0.67). An attempt to provide an alternative definition of cystocele at CDP had a similar outcome ( r=0.63). The present study demonstrates a moderate correlation between clinical and radiologic findings in patients with anterior vaginal wall prolapse. It does not support the use of bladder contrast at radiologic investigation in the routine preoperative assessment of patients with genital prolapse.
Perrin, E; Jackson, M; Grant, R; Lloyd, C; Chinaka, F; Goh, V
2018-02-01
In many centres, a fixed method of contrast-media administration is used for CT regardless of patient body habitus. The aim of this trial was to assess contrast enhancement of the aorta, portal vein, liver and spleen during abdomino-pelvic CT imaging using a weight-adapted contrast media protocol compared to the current fixed dose method. Thirty-nine oncology patients, who had previously undergone CT abdomino-pelvic imaging at the institution using a fixed contrast media dose, were prospectively imaged using a weight-adapted contrast media dose (1.4 ml/kg). The two sets of images were assessed for contrast enhancement levels (HU) at locations in the liver, aorta, portal vein and spleen during portal-venous enhancement phase. The t-test was used to compare the difference in results using a non-inferiority margin of 10 HU. When the contrast dose was tailored to patient weight, contrast enhancement levels were shown to be non-inferior to the fixed dose method (liver p < 0.001; portal vein p = 0.003; aorta p = 0.001; spleen p = 0.001). As a group, patients received a total contrast dose reduction of 165 ml using the weight-adapted method compared to the fixed dose method, with a mean cost per patient of £6.81 and £7.19 respectively. Using a weight-adapted method of contrast media administration was shown to be non-inferior to a fixed dose method of contrast media administration. Patients weighing 76 kg, or less, received a lower contrast dose which may have associated cost savings. A weight-adapted contrast media protocol should be implemented for portal-venous phase abdomino-pelvic CT for oncology patients with adequate renal function (>70 ml/min/1.73 m 2 ). Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Callahan, Michael J; Talmadge, Jennifer M; MacDougall, Robert D; Kleinman, Patricia L; Taylor, George A; Buonomo, Carlo
2017-04-01
In our experience, questions about the appropriate use of enteric contrast media for pediatric fluoroscopic studies are common. The purpose of this article is to provide a comprehensive review of enteric contrast media used for pediatric fluoroscopy, highlighting the routine use of these media at a large tertiary care pediatric teaching hospital.
Ding, Sandrine; Meystre, Nicole Richli; Campeanu, Cosmin; Gullo, Giuseppe
2018-01-01
To identify risk factors and interventions preventing or reducing contrast medium extravasation. Computed tomography (CT) is a radiological examination essential for the diagnosis and monitoring of many diseases. It is often performed with the intravenous (IV) injection of contrast agents. Use of these products can result in a significant complication, extravasation, which is the accidental leakage of IV material into the surrounding tissue. Patients may feel a sharp pain and skin ulceration or necrosis may develop. This review considered studies that included patients (adults and children) undergoing a CT with IV administration of contrast media. The risk factors considered were patient demographics, comorbidities and medication history. This review also investigated any strategies related to: contrast agent, injection per se, material used for injection, apparatus used, healthcare professionals involved, and patient risk assessment performed by the radiology personnel. The comparators were other interventions or usual care. This review investigated randomized controlled trials and non-randomized controlled trials. When neither of these were available, other study designs, such as prospective and retrospective cohort studies, case-control studies and case series, were considered for inclusion. Primary outcomes considered were: extravasation frequency, volume, severity and complications. The databases PubMed, CINAHL, Embase, the Cochrane Register of Controlled Trials, Web of Science PsycINFO, ProQuest Dissertations and Theses A&I, TRIP Database and ClinicalTrials.gov were searched to find both published and unpublished studies from 1980 to September 2016. Papers were assessed by two independent reviewers for methodological validity using the Joanna Briggs Institute System for the Unified Management, Assessment and Review of Information (JBI SUMARI). Data were extracted using the standardized data extraction tool from JBI SUMARI. In one case, quantitative data from two cohort studies were pooled in a statistical meta-analysis. However, generally, statistical pooling was not possible due to heterogeneity of the interventions, populations of interest or outcomes. Accordingly, the findings have been presented in narrative form. Fifteen articles were selected from a total of 2151 unique studies identified. Two were randomized controlled trials and 13 were quasi-experimental and observational studies. The quality of these studies was judged to be low to moderate. Some patient characteristics, such as female sex and inpatient status, appeared to be risk factors for extravasation. Additionally, injection rate, venous access site and catheter dwelling time could affect the volume extravasated. Preliminary studies seemed to indicate the potential of extravasation detection accessories to identify extravasation and reduce the volume extravasated. The other interventions either did not result in significant reduction in the frequency/volume of extravasation, or the results were mixed across the studies. The majority of the studies included in this review evaluated the outcomes of extravasation frequency and volume. Given the quality of the primary studies, this systematic review identified only potential risk factors and interventions. It further highlighted the research gap in this area and the importance of conducting trials with solid methodological designs.
Nonpharmacological Strategies to Prevent Contrast-Induced Acute Kidney Injury
Eiam-Ong, Somchai
2014-01-01
Contrast-induced AKI (CI-AKI) has been one of the leading causes for hospital-acquired AKI and is associated with independent risk for adverse clinical outcomes including morbidity and mortality. The aim of this review is to provide a brief summary of the studies that focus on nonpharmacological strategies to prevent CI-AKI, including routine identification of at-risk patients, use of appropriate hydration regimens, withdrawal of nephrotoxic drugs, selection of low-osmolar contrast media or isoosmolar contrast media, and using the minimum volume of contrast media as possible. There is no need to schedule dialysis in relation to injection of contrast media or injection of contrast agent in relation to dialysis program. Hemodialysis cannot protect the poorly functioning kidney against CI-AKI. PMID:24795882
Kalaiselvan, Vivekanandan; Sharma, Surbhi; Singh, Gyanendra Nath
2014-09-01
Contrast media are used widely to improve medical imaging. Like all other pharmaceuticals, these agents are not completely devoid of risk, and continuous monitoring of adverse reactions with these agents is important. Spontaneous reporting is the simplest method for understanding the safety profile of pharmaceutical products after their approval. Our objective was to identify the pattern and characteristics of adverse reactions attributed to contrast media in the Indian population reported to the National Coordination Centre for the Pharmacovigilance Programme of India (NCC-PvPI). Individual case safety reports (ICSRs) attributed to contrast media submitted spontaneously to the NCC-PvPI were extracted from the database for July 2010 to September 2013. We analysed these reports for information related to reporter's professional category, patient's age and sex, reporter's diagnosis of the reaction, seriousness of the reaction, type of contrast media exposure, system organ class (SOC) affected (as described in World Health Organization Adverse Reaction Terminology [WHO-ART]) and outcome. Of the total 59,915 ICSRs in the database, 415 (0.7%) were suspected adverse reactions to contrast media; 44 reports were serious, including three fatal cases. The most affected SOCs were skin and appendage disorders, body as a whole-general disorders, gastrointestinal system disorders and respiratory system disorders. Hypersensitivity reactions were reported in the majority of ICSRs. The contrast media with the highest number of reports were iohexol (40.7%), iomeprol (17.8%), iopamidol (12%) and diatrizoate (12%). Most of the reactions to contrast media were allergic-like, and no previously unrecognised adverse reactions were observed in the Indian population. Further data and increased awareness among healthcare professionals is required to signal and prevent the consequences of adverse reactions attributed to contrast media.
In vivo differentiation of complementary contrast media at dual-energy CT.
Mongan, John; Rathnayake, Samira; Fu, Yanjun; Wang, Runtang; Jones, Ella F; Gao, Dong-Wei; Yeh, Benjamin M
2012-10-01
To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios. Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium. Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase-enhanced CT scan simultaneously in a single examination. Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo. © RSNA, 2012.
In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT
Mongan, John; Rathnayake, Samira; Fu, Yanjun; Wang, Runtang; Jones, Ella F.; Gao, Dong-Wei
2012-01-01
Purpose: To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios. Materials and Methods: Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium. Results: Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase–enhanced CT scan simultaneously in a single examination. Conclusion: Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo. © RSNA, 2012 PMID:22778447
Reflective practice as a tool to teach digital professionalism.
Kung, Justin W; Eisenberg, Ronald L; Slanetz, Priscilla J
2012-11-01
Digital professionalism is increasingly being integrated into postgraduate medical education. We developed a small-group, reflective practice-based session incorporating radiology-specific cases to heighten residents' awareness about digital professionalism. Case-based, radiology-specific scenarios were created for a small-group, reflective practice-based session on digital professionalism. Anonymous pre- and postsession surveys evaluating residents' use of social media and their thoughts about the session were administered to the radiology residents. Twenty-five of 38 (66%) residents responded to the presession survey with 40% (10/25) reporting daily social media use; 50% (12/24) witnessing an unprofessional posting on Facebook; and 8% (2/25) posting something unprofessional themselves. Of the 21 residents who attended the session, 13 (62%) responded to the postsession survey. Residents reported that the session added to their understanding of professionalism 3.92, 95% CI (3.57-4.27). As a result of the session, residents stated that they were more aware of protecting patient privacy and confidentiality on social media sites 3.92, 95% CI (3.47-4.37), and would take a more active role in ensuring professional use of social media as it relates to patient care 4.00, 95% CI (3.66-4.34). Residents favorably viewed the reflective case-based session on digital professionalism as a means to be more aware of ways to avoid unprofessional interactions on the internet. Our results suggest that such reflective sessions are an effective method to educate residents on key concepts regarding digital professionalism. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
Shen, Yaqi; Hu, Xuemei; Zou, Xianlun; Zhu, Di; Li, Zhen; Hu, Daoyu
2016-09-01
Imaging communities have already reached a consensus that the radiation dose of computed tomography (CT) should be reduced as much as reasonably achievable to lower population risks. Increasing attention is being paid to iodinated contrast media (CM) induced nephrotoxicity (CIN); a decrease in the intake of iodinated CM is required by increasingly more radiologists. Theoretically, the radiation dose varies with the tube current time and square of the tube voltage, with higher iodine contrast at low photon energies (Huda et al. [2000] Radiology, 21 7, 430-435).The use of low tube voltage is a promising strategy to reduce both the radiation dose and CM burden. The term 'double low' has been coined to describe scanning protocols that reduce radiation dose and iodine intake synchronously. These protocols are becoming increasingly popular in the clinical setting. The aim of this review was to describe all original studies using the 'double low' strategy in the last 5 years. We searched an online electronic database (PubMed) from January 2011 to December 2015 for original studies published on the relationship of low tube voltage with low radiation dose and low iodine contrast media burden in patients undergoing CT scans. Studies that failed to reduce radiation dose or iodine CM burden were excluded in this study. Thirty-seven studies aimed at reducing radiation dose using low tube voltage combined with iodine CM reduced protocols were included in this study. Most studies evaluated conditions associated with arteries. Four were cerebral and neck computed tomography angiography (CTA) studies, 15 were pulmonary CTA (pCTA) and coronary CTA (cCTA) studies, one concerned myocardial perfusion, five studies focused on the thoracic and abdominal aorta, and one investigated renal arteries. Three studies consisted of CT venography (CTV) of the pelvis and lower extremities. Six publications examined the liver, and two focused on the kidney. Overall, this review demonstrates that the low tube voltage CT protocol is a powerful tool to reduce the radiation dose in CTA, especially with pCTA and cCTA. © 2016 John Wiley & Sons Ltd.
Quality evaluation of radiographic contrast media in large-volume prefilled syringes and vials.
Sendo, T; Hirakawa, M; Yaginuma, M; Aoyama, T; Oishi, R
1998-06-01
The authors compared the particle contaminations of radiographic contrast media packaged in large-volume prefilled syringes and vials. Particle counting was performed for four contrast media packaged in large-volume prefilled syringes (iohexol, ioversol, ioversol for angiography, and ioxaglate) and three contrast media packaged in vials (iohexol, ioversol, and ioxaglate). X-ray emission spectrometry was performed to characterize the individual particles. The amount of silicone oil in the syringe was quantified with infrared spectrophotometry. The particle contamination in syringes containing ioversol was higher than that in syringes containing iohexol or ioxaglate. Particle contamination in the vials was relatively low, except with ioxaglate. X-ray emission spectrometry of the components of the syringe and vial showed that the source of particles was internal material released from the rubber stopper or inner surface. The particle counts for contrast media packaged in syringes and vials varied considerably among the different contrast media and were related to the amount of silicone oil on the inner surface and rubber piston of the syringe.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pagani, J.J.; Hayman, L.A.; Bigelow, R.H.
1983-04-01
The effect of 5 mg of intravenous diazepam (Valium) on contrast media-associated seizer incidence was studied in a randomized controlled trial involving 284 patients with known or suspected brain metastases undergoing cerebral computed tomography. Of these patients, 188 were found to have brain metastases, and it is estimated that for this subgroup prophylactic diazepam reduces the risk of contrast-assocated seizure by a factor of 0.26. Seizures occurred in three of 96 patients with metastases on diazepam and in 14 of 92 patients with metastases but without diazepam. Factors related to increased risk of contrast media-associated seizures are: (1) prior seizuremore » history due to brain metatases and/or prior contrast, (2) progressive cerebral metastases, and (3) prior or concurrent brain antineoplastic therapy. Factors not related to an increased risk of these seizures are: (1) contrast media dosage, chemical composition, or osmolarity, (2) computed tomographic appearance of metastases, and (3) type of primary malignancy. Concomitant therapeutic levels of diphenylhydantoin (Dilantin) do not protect completely against contrast media-associated seizures. Pathophysiology of contrast media-associated seizures is discussed in view of the risk factors determined by this study.« less
Ozaki, Yuichi; Kitabata, Hironori; Tsujioka, Hiroto; Hosokawa, Seiki; Kashiwagi, Manabu; Ishibashi, Kohei; Komukai, Kenichi; Tanimoto, Takashi; Ino, Yasushi; Takarada, Shigeho; Kubo, Takashi; Kimura, Keizo; Tanaka, Atsushi; Hirata, Kumiko; Mizukoshi, Masato; Imanishi, Toshio; Akasaka, Takashi
2012-01-01
Although an intracoronary frequency-domain optical coherence tomography (FD-OCT) system overcomes several limitations of the time-domain OCT (TD-OCT) system, the former requires injection of contrast media for image acquisition. The increased total amount of contrast media for FD-OCT image acquisition may lead to the impairment of renal function. The safety and usefulness of the non-occlusion method with low-molecular-weight dextran L (LMD-L) via a guiding catheter for TD-OCT image acquisition have been reported previously. The aim of the present study was to compare the image quality and quantitative measurements between contrast media and LMD-L for FD-OCT image acquisition in coronary stented lesions. Twenty-two patients with 25 coronary stented lesions were enrolled in this study. FD-OCT was performed with the continuous-flushing method via a guiding catheter. Both contrast media and LMD-L were infused at a rate of 4 ml/s by an autoinjector. With regard to image quality, the prevalence of clear image segments was comparable between contrast media and LMD-L (97.9% vs. 96.5%, P=0.90). Furthermore, excellent correlations were observed between both flushing solutions in terms of minimum lumen area, mean lumen area, and mean stent area. The total volumes of contrast media and of LMD-L needed for OCT image acquisition were similar. FD-OCT image acquisition with LMD-L has the potential to reduce the total amount of contrast media without loss of image quality.
Effect of X-ray Contrast Media, Chlorination, and Chloramination on Zebrafish Development
Effect of X-ray Contrast Media, Chlorination, and Chloramination on Zebrafish Development Little is known about the vertebrate developmental toxicity of chlorinated or chloraminated drinking water (DW), iodinated X-ray contrast media (ICM, a common contaminate of DW) or how the c...
Social Media and the 21st-Century Scholar: How You Can Harness Social Media to Amplify Your Career.
Chan, Teresa M; Stukus, David; Leppink, Jimmie; Duque, Lina; Bigham, Blair L; Mehta, Neil; Thoma, Brent
2018-01-01
To many physicians and professionals, social media seems to be a risky business. However, recent literature has shown that there is potential to enhance your scholarly brand by engaging your stakeholders online. In this article, we discuss the opportunities presented to modern scholars by social media. Using case studies, we highlight two success stories around how scientists and scholars might use social media to enhance their careers. We also outline five key steps you can follow to build and manage your scholarly presence online. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Saade, Charbel; Deeb, Ibrahim Alsheikh; Mohamad, Maha; Al-Mohiy, Hussain; El-Merhi, Fadi
2016-01-01
Over the last decade, exponential advances in computed tomography (CT) technology have resulted in improved spatial and temporal resolution. Faster image acquisition enabled renal CT angiography to become a viable and effective noninvasive alternative in diagnosing renal vascular pathologies. However, with these advances, new challenges in contrast media administration have emerged. Poor synchronization between scanner and contrast media administration have reduced the consistency in image quality with poor spatial and contrast resolution. Comprehensive understanding of contrast media dynamics is essential in the design and implementation of contrast administration and image acquisition protocols. This review includes an overview of the parameters affecting renal artery opacification and current protocol strategies to achieve optimal image quality during renal CT angiography with iodinated contrast media, with current safety issues highlighted.
Ryu, JiHyeon; Lee, HeeYoung; Suh, JinUk; Yang, MyungSuk; Kang, WonKu; Kim, EunYoung
2015-01-01
We analyzed differences between spontaneously reported drug-induced (not including contrast media) and contrast media-induced adverse reactions. Adverse drug reactions reported by an in-hospital pharmacovigilance center (St. Mary's teaching hospital, Daejeon, Korea) from 2010-2012 were classified as drug-induced or contrast media-induced. Clinical patterns, frequency, causality, severity, Schumock and Thornton's preventability, and type A/B reactions were recorded. The trends among causality tools measuring drug and contrast-induced adverse reactions were analyzed. Of 1,335 reports, 636 drug-induced and contrast media-induced adverse reactions were identified. The prevalence of spontaneously reported adverse drug reaction-related admissions revealed a suspected adverse drug reaction-reporting rate of 20.9/100,000 (inpatient, 0.021%) and 3.9/100,000 (outpatients, 0.004%). The most common adverse drug reaction-associated drug classes included nervous system agents and anti-infectives. Dermatological and gastrointestinal adverse drug reactions were most frequently and similarly reported between drug and contrast media-induced adverse reactions. Compared to contrast media-induced adverse reactions, drug-induced adverse reactions were milder, more likely to be preventable (9.8% vs. 1.1%, p < 0.001), and more likely to be type A reactions (73.5% vs. 18.8%, p < 0.001). Females were over-represented among drug-induced adverse reactions (68.1%, p < 0.001) but not among contrast media-induced adverse reactions (56.6%, p = 0.066). Causality patterns differed between the two adverse reaction classes. The World Health Organization-Uppsala Monitoring Centre causality evaluation and Naranjo algorithm results significantly differed from those of the Korean algorithm version II (p < 0.001). We found differences in sex, preventability, severity, and type A/B reactions between spontaneously reported drug and contrast media-induced adverse reactions. The World Health Organization-Uppsala Monitoring Centre and Naranjo algorithm causality evaluation afforded similar results.
Suh, JinUk; Yang, MyungSuk; Kang, WonKu; Kim, EunYoung
2015-01-01
Objective We analyzed differences between spontaneously reported drug-induced (not including contrast media) and contrast media-induced adverse reactions. Methods Adverse drug reactions reported by an in-hospital pharmacovigilance center (St. Mary’s teaching hospital, Daejeon, Korea) from 2010–2012 were classified as drug-induced or contrast media-induced. Clinical patterns, frequency, causality, severity, Schumock and Thornton’s preventability, and type A/B reactions were recorded. The trends among causality tools measuring drug and contrast-induced adverse reactions were analyzed. Results Of 1,335 reports, 636 drug-induced and contrast media-induced adverse reactions were identified. The prevalence of spontaneously reported adverse drug reaction-related admissions revealed a suspected adverse drug reaction-reporting rate of 20.9/100,000 (inpatient, 0.021%) and 3.9/100,000 (outpatients, 0.004%). The most common adverse drug reaction-associated drug classes included nervous system agents and anti-infectives. Dermatological and gastrointestinal adverse drug reactions were most frequently and similarly reported between drug and contrast media-induced adverse reactions. Compared to contrast media-induced adverse reactions, drug-induced adverse reactions were milder, more likely to be preventable (9.8% vs. 1.1%, p < 0.001), and more likely to be type A reactions (73.5% vs. 18.8%, p < 0.001). Females were over-represented among drug-induced adverse reactions (68.1%, p < 0.001) but not among contrast media-induced adverse reactions (56.6%, p = 0.066). Causality patterns differed between the two adverse reaction classes. The World Health Organization–Uppsala Monitoring Centre causality evaluation and Naranjo algorithm results significantly differed from those of the Korean algorithm version II (p < 0.001). Conclusions We found differences in sex, preventability, severity, and type A/B reactions between spontaneously reported drug and contrast media-induced adverse reactions. The World Health Organization–Uppsala Monitoring Centre and Naranjo algorithm causality evaluation afforded similar results. PMID:26544039
Radioactive Waste Management Complex low-level waste radiological performance assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maheras, S.J.; Rood, A.S.; Magnuson, S.O.
This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsitemore » receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected.« less
Tuberculous otitis media: a clinical and radiologic analysis of 52 patients.
Cho, Yang-Sun; Lee, Hyun-Seok; Kim, Sang-Woo; Chung, Kyu-Hwan; Lee, Dong-Kyung; Koh, Won-Jung; Kim, Myung-Gu
2006-06-01
This retrospective study reports on the clinical and radiologic features and the treatment outcomes of patients with tuberculous otitis media (TOM). We reviewed the medical records of 52 patients (53 ears) with TOM between 1993 and 2005 and analyzed temporal bone computed tomography scans of 23 patients. The diagnosis of TOM was made if a specimen of the middle ear revealed the presence of acid fast bacilli (AFB), grew Mycobacterium tuberculosis (M. Tb) on a culture, revealed characteristic histology, and/or was positive for polymerase chain reaction (PCR) for M. Tb. The highest incidence of the disease was observed among patients in their 30s. The main symptom was otorrhea, and the duration of symptoms was shorter than with nonspecific chronic otitis media. Most patients demonstrated a moderate to severe hearing loss. Five patients (9.6%) demonstrated a peripheral-type facial palsy. Temporal bone CT scans demonstrated relatively well-pneumatized mastoids and occupation by soft tissue of the entire tympanum and mastoid air cells. Six patients demonstrated bone destruction that involved the cortex of the mastoid bone. In most patients, antituberculous medication was effective treatment. The patients who underwent chemotherapy after surgery achieved more rapid healing of the ear and more frequent closure of the tympanic membrane than those who did not receive surgery. Clinicians should have a high index of suspicion and be aware of the clinical and radiologic characteristics of TOM.
Tuberculous otitis media developing as a complication of tympanostomy tube insertion.
Kim, Chang Woo; Jin, Jae Won; Rho, Young-Soo
2007-03-01
Primary tuberculous otitis media of which infection focus cannot be found elsewhere in the body is a rare disease. Route of the infection has been hypothesized as Eustachian tube or external auditory canal with tympanic membrane perforation but it is hard to ascertain in the patient. We present a case of an 8-year-old child who suffered chronic otorrhea after tympanostomy tube insertion. The radiological and histopathological findings revealed tuberculous otitis media, which occurred as a complication of tympanostomy tube insertion.
Wang, Carolyn L; Chinnugounder, Sankar; Hippe, Daniel S; Zaidi, Sadaf; O'Malley, Ryan B; Bhargava, Puneet; Bush, William H
2017-01-01
To assess the performance of interprofessional teams of radiologists, technologists, and nurses trained with high-fidelity hands-on (HO) simulation and computer-based (CB) simulation training for contrast reaction management (CR) and teamwork skills (TS). Nurses, technologists, and radiology residents were randomized into 11 teams of three (one of each). Six teams underwent HO training and five underwent CB training for CR and TS. Participants took written tests before and after training and were further tested using a high-fidelity simulation scenario. HO and CB groups scored similarly on all written tests and each showed improvement after training (P = .002 and P = .018, respectively). During the final scenario test, HO teams tended to receive higher grades than CB teams on CR (95% versus 81%, P = .17) and made fewer errors in epinephrine administration (0/6 versus 2/5, P = .18). HO and CB teams scored similarly on TS (51% versus 52%, P = .66), but overall scores were lower for TS than for CR skills in both the HO (P = .03) and CB teams (P = .06). HO training was more highly rated than CB as an effective educational tool (P = .01) and for effectiveness at teaching CR and team communication skills (P = .02). High-fidelity simulation can be used to both train and test interprofessional teams of radiologists, technologists, and nurses for both CR and TS and is more highly rated as an effective educational tool by participants than similar CB training. However, a single session of either type of training may be inadequate for mastering TS. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Iodinated contrast media and the role of renal replacement therapy.
Weisbord, Steven D; Palevsky, Paul M
2011-05-01
Iodinated contrast media are among the most commonly used pharmacologic agents in medicine. Although generally highly safe, iodinated contrast media are associated with several adverse effects, most significantly the risk of acute kidney injury, particularly in patients with underlying renal dysfunction. By virtue of their pharmacokinetic characteristics, these contrast agents are efficiently cleared by hemodialysis and to a lesser extent, hemofiltration. This has led to research into the capacity for renal replacement therapies to prevent certain adverse effects of iodinated contrast. This review examines the molecular and pharmacokinetic characteristics of iodinated contrast media and critically analyzes data from past studies on the role of renal replacement therapy to prevent adverse effects of these diagnostic agents. Published by Elsevier Inc.
Influence of MRI contrast media on histamine release from mast cells.
Kun, Tomasz; Jakubowski, Lucjusz
2012-07-01
Mast cells, owing to diversity of secreted mediators, play a crucial role in the regulation of inflammatory response. Together with basophils, mast cells constitute a central pathogenetic element of anaphylactic (IgE-dependent) and anaphylactoid (IgE-independent) reactions. In severe cases, generalized degranulation of mast cells may cause symptoms of anaphylactic shock. The influence of the classical, iodine-based contrast media on mastocyte degranulation has been fully described. Our objective was to determine the influence of the gadolinium-based MRI contrast media on histamine release from mast cells and to compare the activity of ionic and non-ionic preparations of contrast media. To determine the intensity of mast cell degranulation, we used an experimental model based on mastocytes isolated from rat peritoneal fluid. Purified suspensions of mast cells were incubated with various concentrations of Gd-DTPA and Gd-DTPA-BMA, and solutions of PEG 600 which served as a non-toxic osmotic stimulus. The intensity of mast cell activation was presented as mean percentage of histamine released from cells after incubation. The obtained results demonstrate that both ionic and non-ionic preparations of the MRI contrast media are able to induce mast cell degranulation in vitro. It was also proved that the non-ionic MRI contrast media stimulate mast cells markedly more weakly than ionic contrast media at identical concentration. The aforementioned results may suggest a more profitable safety profile of the non-ionic contrast preparations. We may also conclude that triggering of mast cell degranulation after incubation with the solutions of MRI contrast media results from non-specific osmotic stimulation and direct toxicity of free ionic residues.
Thongprayoon, Charat; Cheungpasitporn, Wisit; Podboy, Alexander J; Gillaspie, Erin A; Greason, Kevin L; Kashani, Kianoush B
2016-11-01
The goal of this systematic review was to assess the effects of contrast media volume on transcatheter aortic valve replacement-related acute kidney injury. A literature search was performed using Medline, EMbase, the Cochrane Database of Systematic Reviews, and clinicaltrials.gov from the inception of these databases through December 2015. Studies that reported relative risk, odds ratio, or hazard ratio comparing the risks of acute kidney injury following transcatheter aortic valve replacement in patients who received high contrast media volume were included. Pooled risk ratio (RR) and 95% confidence intervals (95% CI) were calculated using a random-effect, generic inverse variance method. Four cohort studies composed of 891 patients were included in the analyses to assess the risk of acute kidney injury after transcatheter aortic valve replacement in patients who received high contrast media volume. The pooled RR of acute kidney injury after transcatheter aortic valve replacement in patients who received a large volume of contrast media was 1.41 (95% CI, 0.87 to 2.28) compared with low contrast media volume. The meta-analysis was limited to studies using standard acute kidney injury definitions, and the pooled RR of acute kidney injury in patients who received high contrast media volume is 1.12 (95% CI, 0.78 to 1.62). Our meta-analysis shows no significant association between contrast media volume and risk of acute kidney injury after transcatheter aortic valve replacement. © 2016 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.
[Diagnostic Significance of BAT in Anaphylaxis to Non-ionic Contrast Media].
Zhang, Hao-yue; Xu, Su-jun; Tang, Xiao-xian; Niu, Ji-jun; Guo, Xiang-jie; Gao, Cai-rong
2015-06-01
To investigate the diagnostic significance of basophil activation test (BAT) in anaphylaxis to non-ionic contrast media through testing the content of CD63, mast cell-carboxypeptidase A3 (MC-CPA3), and terminal complement complex SC5b-9 of the individuals by testing their levels in the normal immune group and the anaphylaxis groups to β-lactam drugs and non -ionic contrast media. The CD63 expression of basophilic granulocyte in blood was detected by flow cytometry. The levels of MC-CPA3 in blood serum and SC5b-9 in blood plasma were detected by ELISA. The CD63 expression of basophilic granulocyte in blood, the levels of MC-CPA3 and SC5b-9 of anaphylaxis to non-ionic contrast media and β-lactam drugs were significantly higher than that in normal immune group (P < 0.05). There is activation of basophilic granulocytes, mast cells and complement system in anaphylaxis to non-ionic contrast media. BAT can be used to diagnose the anaphylaxis to non-ionic contrast media.
Saade, Charbel; Deeb, Ibrahim Alsheikh; Mohamad, Maha; Al-Mohiy, Hussain; El-Merhi, Fadi
2016-01-01
Over the last decade, exponential advances in computed tomography (CT) technology have resulted in improved spatial and temporal resolution. Faster image acquisition enabled renal CT angiography to become a viable and effective noninvasive alternative in diagnosing renal vascular pathologies. However, with these advances, new challenges in contrast media administration have emerged. Poor synchronization between scanner and contrast media administration have reduced the consistency in image quality with poor spatial and contrast resolution. Comprehensive understanding of contrast media dynamics is essential in the design and implementation of contrast administration and image acquisition protocols. This review includes an overview of the parameters affecting renal artery opacification and current protocol strategies to achieve optimal image quality during renal CT angiography with iodinated contrast media, with current safety issues highlighted. PMID:26728701
Preventing tuberculosis in healthcare workers of the radiology department: a Malaysian perspective.
Tan, Lh; Kamarulzaman, A
2006-01-01
Tuberculosis (TB) is a well recognised occupational hazard for healthcare workers (HCWs). Concerns on the safety of healthcare settings in Malaysia was raised following a report of 25 HCWs working in 11 general hospitals in Malaysia who were infected with TB in 2004 being publicised in the media recently. As the disease burden in general is high in Malaysia, due attention should be given to this disease in our healthcare facilities including the radiology department, an often neglected area in TB infection control programmes. This article focuses on the key control measures that can be implemented in radiology departments in a developing country with limited resources.
Allergic reactions to iodinated contrast media: premedication considerations for patients at risk.
Schopp, Jennifer G; Iyer, Ramesh S; Wang, Carolyn L; Petscavage, Jonelle M; Paladin, Angelisa M; Bush, William H; Dighe, Manjiri K
2013-08-01
The objectives of this article are to review allergy-type reactions to iodinated contrast media and the protocols utilized to prevent or reduce the occurrence of these adverse reactions in high-risk patients. We will begin by discussing the types or classifications of the adverse reactions to iodinated contrast media. We will then discuss reaction mechanisms, identify the patients at highest risk for adverse reactions, and clarify common misperceptions about the risk. Finally, we will discuss the actions of the medications used to help reduce or prevent allergy-type reactions to iodinated contrast media, the protocols used to help reduce or prevent contrast reactions in high-risk patients, and the potential side effects of these medications. We will also discuss the high-risk patient who has received premedication due to a prior index reaction and discuss the risk of having a subsequent reaction, termed "breakthrough reaction." Identifying patient at high risk for an "allergy-type" reaction to contrast media is an essential task of the radiologist. Prevention of or reduction of the risk of an adverse reaction is critical to patient safety. If an examination can be performed without contrast in a patient at high risk for an allergy-type reaction, it may be appropriate to avoid contrast. However, there are situations where contrast media is necessary, and the radiologist plays a vital role in preventing or mitigating an allergy-type reaction.
Hawkins, C Matthew; Hunter, Makeba; Kolenic, Giselle E; Carlos, Ruth C
2017-05-01
To prospectively evaluate the impact of increasing levels of social media engagement on page visits and web-link clicks for content published in the Journal of the American College of Radiology. A three-arm prospective trial was designed using a control group, a basic Twitter intervention group (using only the Journal's @JACRJournal Twitter account), and an enhanced Twitter intervention group (using the personal Twitter accounts of editorial board members and trainees). Overall, 428 articles published between June 2013 and July 2015 were randomly assigned to the three groups. Article-specific tweets for both intervention arms were sent between September 14, 2015, and October 28, 2015. Primary end points included article-specific weekly and monthly page visits on the journal's Elsevier website (Amsterdam, Netherlands). For the two intervention groups, additional end points included 7-day and 30-day Twitter link clicks. Weekly page visits for the enhanced Twitter arm (mean 18.2; 95% confidence interval [CI] 15.6-20.7) were significantly higher when compared with the weekly page visits for the control arm (mean 7.6; 95% CI 1.7-13.6). However, there was no demonstrable increase in weekly page visits (mean 9.4; 95% CI 7.4-11.5) for the basic Twitter arm compared with the control arm. No intervention effects over control, regardless of Twitter arm assignment, were demonstrated for monthly page visits. The enhanced Twitter intervention resulted in a statistically significant increase in both 7-day and 30-day Twitter link clicks compared with the basic Twitter intervention group. An organized social media strategy, with focused social media activity from editorial board members, increased engagement with content published in a peer-reviewed radiology journal. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Performance evaluation of a digital mammography unit using a contrast-detail phantom
NASA Astrophysics Data System (ADS)
Elizalde-Cabrera, J.; Brandan, M.-E.
2015-01-01
The relation between image quality and mean glandular dose (MGD) has been studied for a Senographe 2000D mammographic unit used for research in our laboratory. The magnitudes were evaluated for a clinically relevant range of acrylic thicknesses and radiological techniques. The CDMAM phantom was used to determine the contrast-detail curve. Also, an alternative method based on the analysis of signal-to-noise (SNR) and contrast-to-noise (CNR) ratios from the CDMAM image was proposed and applied. A simple numerical model was utilized to successfully interpret the results. Optimum radiological techniques were determined using the figures-of-merit FOMSNR=SNR2/MGD and FOMCNR=CNR2/MGD. Main results were: the evaluation of the detector response flattening process (it reduces by about one half the spatial non-homogeneities due to the X- ray field), MGD measurements (the values comply with standards), and verification of the automatic exposure control performance (it is sensitive to fluence attenuation, not to contrast). For 4-5 cm phantom thicknesses, the optimum radiological techniques were Rh/Rh 34 kV to optimize SNR, and Rh/Rh 28 kV to optimize CNR.
Rebière, Marilou; Verburg, Frederik A; Palmowski, Moritz; Krohn, Thomas; Pietsch, Hubertus; Kuhl, Christiane K; Mottaghy, Felix M; Behrendt, Florian F
2012-08-01
To evaluate the influence of multiphase CT scanning and different intravenous contrast media on contrast enhancement, attenuation correction and image quality in combined PET/CT. 140 patients were prospectively enrolled for F-18-FDG-PET/CT including a low-dose unenhanced, arterial and venous contrast enhanced CT. The first (second) 70 patients, received contrast medium with 370 (300) mg iodine/ml. The iodine delivery rate (1.3mg/s) and total iodine load (44.4g) were identical for both groups. Contrast enhancement and maximum and mean standardized FDG uptake values (SUVmax and SUVmean) were determined for the un-enhanced, arterial and venous PET/CT at multiple anatomic sites and PET reconstructions were visually evaluated. Arterial contrast enhancement was significantly higher for the 300mg/ml contrast medium compared to 370mgI/ml at all anatomic sites. Venous enhancement was not different between the two contrast media. SUVmean and SUVmax were significantly higher for the contrast enhanced compared to the non-enhanced PET/CT at all anatomic sites (all P<0.001). Tracer uptake was significantly higher in the arterial than in the venous PET/CT in the arteries using both contrast media (all P<0.001). No differences in tracer uptake were found between the contrast media (all P>0.05). Visual assessment revealed no relevant differences between the different PET reconstructions. There is no relevant qualitative influence on the PET scan from the use of different intravenous contrast media in its various phases in combined multiphase PET/CT. For quantitative analysis of tracer uptake it is required to use an identical PET/CT protocol. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Delayed adverse reactions to the parenteral administration of iodinated contrast media.
Egbert, Robert E; De Cecco, Carlo N; Schoepf, U Joseph; McQuiston, Andrew D; Meinel, Felix G; Katzberg, Richard W
2014-12-01
This article presents an overview of delayed adverse reactions (DARs) to parenteral iodinated contrast media and discusses the clinical nature, risk factors, mechanisms, and potential economic implications of these DARs. DARs to contrast media are not rare but are often not recognized as being linked to contrast administration and may be falsely ascribed to other drugs. These side effects are problematic because the patient is usually without medical supervision.
Wang, Carolyn L; Schopp, Jennifer G; Petscavage, Jonelle M; Paladin, Angelisa M; Richardson, Michael L; Bush, William H
2011-06-01
The objective of our study was to assess whether high-fidelity simulation-based training is more effective than traditional didactic lecture to train radiology residents in the management of contrast reactions. This was a prospective study of 44 radiology residents randomized into a simulation group versus a lecture group. All residents attended a contrast reaction didactic lecture. Four months later, baseline knowledge was assessed with a written test, which we refer to as the "pretest." After the pretest, the 21 residents in the lecture group attended a repeat didactic lecture and the 23 residents in the simulation group underwent high-fidelity simulation-based training with five contrast reaction scenarios. Next, all residents took a second written test, which we refer to as the "posttest." Two months after the posttest, both groups took a third written test, which we refer to as the "delayed posttest," and underwent performance testing with a high-fidelity severe contrast reaction scenario graded on predefined critical actions. There was no statistically significant difference between the simulation and lecture group pretest, immediate posttest, or delayed posttest scores. The simulation group performed better than the lecture group on the severe contrast reaction simulation scenario (p = 0.001). The simulation group reported improved comfort in identifying and managing contrast reactions and administering medications after the simulation training (p ≤ 0.04) and was more comfortable than the control group (p = 0.03), which reported no change in comfort level after the repeat didactic lecture. When compared with didactic lecture, high-fidelity simulation-based training of contrast reaction management shows equal results on written test scores but improved performance during a high-fidelity severe contrast reaction simulation scenario.
Federle, Michael P; Jaffe, Tracy A; Davis, Peter L; Al-Hawary, Mahmoud M; Levine, Marc S
2017-01-01
One of the significant challenges facing radiologists who perform and interpret studies of the gastrointestinal and genitourinary systems have been periodic interruptions in the availability of barium and iodinated contrast media specially formulated for gastrointestinal (GI) and genitourinary (GU) studies. These interruptions are due to the US Food and Drug Administration's recent requirement for more stringent documentation of the safety and efficacy of contrast media and the consolidation among contrast manufacturers. Therefore, radiologists may be required to recommend an alternative means of evaluation, such as computed tomography, magnetic resonance, or endoscopy, or they may need to substitute a different formulation of a contrast agent not specifically developed for GI or GU use, for example the utilization of an agent designed and marketed for vascular use. This article reviews the current status of fluoroscopic contrast media, and provides suggestions and recommendations for the optimal and alternative use of contrast media formulations.
Callahan, Michael J; Talmadge, Jennifer M; MacDougall, Robert; Buonomo, Carlo; Taylor, George A
2016-05-01
Enteric contrast media are commonly administered for diagnostic cross-sectional imaging studies in the pediatric population. The purpose of this manuscript is to review the use of enteric contrast media for CT, MRI, and ultrasound in infants, children, and adolescents and to share our experiences at a large tertiary care pediatric teaching hospital. The use of enteric contrast material for diagnostic imaging in infants and children continues to evolve with advances in imaging technology and available enteric contrast media. Many principles of enteric contrast use in pediatric imaging are similar to those in adult imaging, but important differences must be kept in mind when imaging the gastrointestinal tract in infants and children, and practical ways to optimize the imaging examination and the patient experience should be employed where possible.
Nonimmediate hypersensitivity reactions to iodinated contrast media.
Gómez, Enrique; Ariza, Adriana; Blanca-López, Natalia; Torres, Maria J
2013-08-01
To provide a detailed analysis of the latest findings on the mechanisms underlying the nonimmediate reactions to iodinated contrast media and comment on the recent advances in diagnosis, focusing on the roles of the skin test, drug provocation test (DPT), and lymphocyte transformation test (LTT). Several studies have reported new findings supporting an important role for T-lymphocytes in the nonimmediate reactions to iodinated contrast media. The LTT has been used as an in-vitro tool for diagnosis, but with variable results. However, the inclusion of autologous monocyte-derived dendritic cells as professional antigen-presenting cells has improved the sensitivity of this test. Regarding in-vivo diagnosis, although skin testing has been routine, it has now been shown that its sensitivity and negative predictive value are low. Recent studies have demonstrated that the DPT is a well tolerated and useful procedure that is necessary to confirm the diagnosis of nonimmediate hypersensitivity reactions to iodinated contrast media. Nonimmediate reactions to contrast media are usually T-cell mediated. Diagnosis is based on skin testing, although its sensitivity and negative predictive value are not optimal. Consequently, drug provocation testing is often needed to confirm the diagnosis and also to seek alternative contrast media that can be tolerated.
Radioactive Waste Management Complex performance assessment: Draft
DOE Office of Scientific and Technical Information (OSTI.GOV)
Case, M.J.; Maheras, S.J.; McKenzie-Carter, M.A.
1990-06-01
A radiological performance assessment of the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory was conducted to demonstrate compliance with appropriate radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the general public. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the general public via air, ground water, and food chain pathways. Projections of doses were made for both offsite receptors and individuals intruding onto the site after closure. In addition, uncertainty analyses were performed. Resultsmore » of calculations made using nominal data indicate that the radiological doses will be below appropriate radiological criteria throughout operations and after closure of the facility. Recommendations were made for future performance assessment calculations.« less
Goske, Marilyn J; Applegate, Kimberly E; Boylan, Jennifer; Butler, Priscilla F; Callahan, Michael J; Coley, Brian D; Farley, Shawn; Frush, Donald P; Hernanz-Schulman, Marta; Jaramillo, Diego; Johnson, Neil D; Kaste, Sue C; Morrison, Gregory; Strauss, Keith J
2008-12-01
Communication campaigns are an accepted method for altering societal attitudes, increasing knowledge, and achieving social and behavioral change particularly within public health and the social sciences. The Image Gently(SM) campaign is a national education and awareness campaign in radiology designed to promote the need for and opportunities to decrease radiation to children when CT scans are indicated. In this article, the relatively new science of social marketing is reviewed and the theoretical basis for an effective communication campaign in radiology is discussed. Communication strategies are considered and the type of outcomes that should be measured are reviewed. This methodology has demonstrated that simple, straightforward safety messages on radiation protection targeted to medical professionals throughout the radiology community, utilizing multiple media, can affect awareness potentially leading to change in practice.
Tirnaksiz, M B; Deschamps, C; Allen, M S; Johnson, D C; Pairolero, P C
2005-01-01
Aqueous contrast swallow study is recommended as a screening procedure for the evaluation of esophageal anastomotic integrity following esophagectomy. The aim of this study was to assess the accuracy of water-soluble contrast swallow screening as a predictor of clinically significant anastomotic leak in patients with esophagectomy. The records of 505 consecutive patients undergoing esophagectomy in Mayo Clinic from January 1991 through December 1995 were retrospectively reviewed. 464 (92%) patients had water-soluble contrast swallows performed in the early postoperative period (median postoperative day 7, range 4-11 days). A total of 39 radiological leaks were obtained but only 17 of these had clinical signs of anastomotic leakage. Furthermore, 25 patients who had normal swallow study developed a clinical anastomotic leak. There were therefore 22 (4.7%) false positive and 25 (5.4%) false negative results giving values for the specificity, sensitivity and false negative error rate of the radiological examination of 94.7, 40.4, and 59.5% respectively. Aspiration of the contrast agent was noted on fluoroscopy in 30 (6.5%) patients. Only 2 (0.4%) patients developed aqueous contrast agent-caused aspiration pneumonia. There was no procedure-related mortality. While radiological assessment of esophageal anastomoses in the early postoperative period using aqueous contrast agents appears to be a relatively safe procedure, the poor sensitivity and high false negative error rate of this technique, when performed on postoperative day 7 and in a series with clinical anastomotic leak rate of 9%, is insufficient for it to be worthwhile as a screening procedure. Copyright (c) 2005 S. Karger AG, Basel.
Iodinated Contrast Media-Induced Thyroid Dysfunction in Euthyroid Nodular Goiter Patients.
Kornelius, Edy; Chiou, Jeng-Yuan; Yang, Yi-Sun; Lo, Shih-Chang; Peng, Chiung-Huei; Lai, Yung-Rung; Huang, Chien-Ning
2016-08-01
The risks of thyroid dysfunction after iodinated contrast media exposure in patients with euthyroid nodular goiter are largely unknown. This observational, retrospective cohort study included a random selection of one million people in Taiwan. All patients with iodinated contrast media exposure during this study period were selected. Patients with euthyroid nodular goiter were identified as cases, while patients without thyroid nodule were selected as controls. We followed these patients until the first event of thyroid dysfunction including hyperthyroidism or hypothyroidism after iodinated contrast media exposure. A total of 334 cases and 2672 matched controls were selected in this study. The mean age of cases and controls were 58.6 and 58.4 years old, and mean follow-up durations were 2.1 and 2 years respectively. After adjustment, patients with euthyroid nodular goiter had a higher risk of thyroid dysfunction (hazard ratio 5.43, [confidence interval (CI) 3.01-9.80]) compared with controls after iodinated contrast media exposure. In the subgroup analysis, the risks of hyperthyroidism and hypothyroidism in cases compared with controls were 5.77 [CI 2.64-12.62] and 4.95 [CI 2.15-11.40] respectively. Half of the euthyroid nodular goiter cases developed thyroid dysfunction within one year after iodinated contrast media exposure. Interestingly, all thyroid-related comorbidities and drug prescriptions did not increase the risk of thyroid dysfunction. Presence of euthyroid nodular goiter was associated with higher risk of thyroid dysfunction including hyperthyroidism and hypothyroidism after iodinated contrast media exposure.
Tomsick, T A; Foster, L D; Liebeskind, D S; Hill, M D; Carrozella, J; Goyal, M; von Kummer, R; Demchuk, A M; Dzialowski, I; Puetz, V; Jovin, T; Morales, H; Palesch, Y Y; Broderick, J; Khatri, P; Yeatts, S D
2015-11-01
Intracarotid arterial infusion of nonionic, low-osmolal iohexol contrast medium has been associated with increased intracranial hemorrhage in a rat middle cerebral artery occlusion model compared with saline infusion. Iso-osmolal iodixanol (290 mOsm/kg H2O) infusion demonstrated smaller infarcts and less intracranial hemorrhage compared with low-osmolal iopamidol and saline. No studies comparing iodinated radiographic contrast media in human stroke have been performed, to our knowledge. We hypothesized that low-osmolal contrast media may be associated with worse outcomes compared with iodixanol in the Interventional Management of Stroke III Trial (IMS III). We reviewed prospective iodinated radiographic contrast media data for 133 M1 occlusions treated with endovascular therapy. We compared 5 prespecified efficacy and safety end points (mRS 0-2 outcome, modified TICI 2b-3 reperfusion, asymptomatic and symptomatic intracranial hemorrhage, and mortality) between those receiving iodixanol (n = 31) or low-osmolal contrast media (n = 102). Variables imbalanced between iodinated radiographic contrast media types or associated with outcome were considered potential covariates for the adjusted models. In addition to the iodinated radiographic contrast media type, final covariates were those selected by using the stepwise method in a logistic regression model. Adjusted relative risks were then estimated by using a log-link regression model. Of baseline or endovascular therapy variables potentially linked to outcome, prior antiplatelet agent use was more common and microcatheter iodinated radiographic contrast media injections were fewer with iodixanol. Relative risk point estimates are in favor of iodixanol for the 5 prespecified end points with M1 occlusion. The percentage of risk differences are numerically greater for microcatheter injections with iodixanol. While data favoring the use of iso-osmolal iodixanol for reperfusion of M1 occlusion following IV rtPA are inconclusive, potential pathophysiologic mechanisms suggesting clinical benefit warrant further investigation. © 2015 by American Journal of Neuroradiology.
Stacul, Fulvio; Bertolotto, Michele; Thomsen, Henrik S; Pozzato, Gabriele; Ugolini, Donatella; Bellin, Marie-France; Bongartz, Georg; Clement, Olivier; Heinz-Peer, Gertraud; van der Molen, Aart; Reimer, Peter; Webb, Judith A W
2018-02-01
Many radiologists and clinicians still consider multiple myeloma (MM) and monoclonal gammopathies (MG) a contraindication for using iodine-based contrast media. The ESUR Contrast Media Safety Committee performed a systematic review of the incidence of post-contrast acute kidney injury (PC-AKI) in these patients. A systematic search in Medline and Scopus databases was performed for renal function deterioration studies in patients with MM or MG following administration of iodine-based contrast media. Data collection and analysis were performed according to the PRISMA statement 2009. Eligibility criteria and methods of analysis were specified in advance. Cohort and case-control studies reporting changes in renal function were included. Thirteen studies were selected that reported 824 iodine-based contrast medium administrations in 642 patients with MM or MG, in which 12 unconfounded cases of PC-AKI were found (1.6 %). The majority of patients had intravenous urography with high osmolality ionic contrast media after preparatory dehydration and purgation. MM and MG alone are not risk factors for PC-AKI. However, the risk of PC-AKI may become significant in dehydrated patients with impaired renal function. Hypercalcaemia may increase the risk of kidney damage, and should be corrected before contrast medium administration. Assessment for Bence-Jones proteinuria is not necessary. • Monoclonal gammopathies including multiple myeloma are a large spectrum of disorders. • In monoclonal gammopathy with normal renal function, PC-AKI risk is not increased. • Renal function is often reduced in myeloma, increasing the risk of PC-AKI. • Correction of hypercalcaemia is necessary in myeloma before iodine-based contrast medium administration. • Bence-Jones proteinuria assessment in myeloma is unnecessary before iodine-based contrast medium administration.
Ding, Sandrine; Meystre, Nicole Richli; Campeanu, Cosmin; Gullo, Giuseppe
2018-01-01
ABSTRACT Objective: To identify risk factors and interventions preventing or reducing contrast medium extravasation. Introduction: Computed tomography (CT) is a radiological examination essential for the diagnosis and monitoring of many diseases. It is often performed with the intravenous (IV) injection of contrast agents. Use of these products can result in a significant complication, extravasation, which is the accidental leakage of IV material into the surrounding tissue. Patients may feel a sharp pain and skin ulceration or necrosis may develop. Inclusion criteria: This review considered studies that included patients (adults and children) undergoing a CT with IV administration of contrast media. The risk factors considered were patient demographics, comorbidities and medication history. This review also investigated any strategies related to: contrast agent, injection per se, material used for injection, apparatus used, healthcare professionals involved, and patient risk assessment performed by the radiology personnel. The comparators were other interventions or usual care. This review investigated randomized controlled trials and non-randomized controlled trials. When neither of these were available, other study designs, such as prospective and retrospective cohort studies, case-control studies and case series, were considered for inclusion. Primary outcomes considered were: extravasation frequency, volume, severity and complications. Methods: The databases PubMed, CINAHL, Embase, the Cochrane Register of Controlled Trials, Web of Science PsycINFO, ProQuest Dissertations and Theses A&I, TRIP Database and ClinicalTrials.gov were searched to find both published and unpublished studies from 1980 to September 2016. Papers were assessed by two independent reviewers for methodological validity using the Joanna Briggs Institute System for the Unified Management, Assessment and Review of Information (JBI SUMARI). Data were extracted using the standardized data extraction tool from JBI SUMARI. In one case, quantitative data from two cohort studies were pooled in a statistical meta-analysis. However, generally, statistical pooling was not possible due to heterogeneity of the interventions, populations of interest or outcomes. Accordingly, the findings have been presented in narrative form. Results: Fifteen articles were selected from a total of 2151 unique studies identified. Two were randomized controlled trials and 13 were quasi-experimental and observational studies. The quality of these studies was judged to be low to moderate. Some patient characteristics, such as female sex and inpatient status, appeared to be risk factors for extravasation. Additionally, injection rate, venous access site and catheter dwelling time could affect the volume extravasated. Preliminary studies seemed to indicate the potential of extravasation detection accessories to identify extravasation and reduce the volume extravasated. The other interventions either did not result in significant reduction in the frequency/volume of extravasation, or the results were mixed across the studies. Conclusions: The majority of the studies included in this review evaluated the outcomes of extravasation frequency and volume. Given the quality of the primary studies, this systematic review identified only potential risk factors and interventions. It further highlighted the research gap in this area and the importance of conducting trials with solid methodological designs. PMID:29324560
Fixed drug eruption associated with intravenous contrast media: report in a woman receiving iohexol.
Wright, Natalie A; Cohen, Philip R
2011-07-01
Fixed drug eruption, a medication-associated mucocutaneous reaction, rarely presents as a delayed adverse reaction to intravenous non-ionic contrast media. We describe a 57-year-old woman with a history of metastatic renal cell carcinoma who repeatedly developed a sharply demarcated, erythematous patch on her left breast after receiving the iodinated non-ionic contrast media iohexol for staging computed tomography scans. Recurrent fixed drug eruption may be avoided by using another contrast medium. Prophylactic treatment with systemic corticosteroids may prevent repeated fixed drug eruption if an alternative contrast agent cannot be used.
Abes, Generoso T; Abes, Franco Louie L B; Jamir, Joselito C
2011-06-01
Tuberculosis (TB) is a rare cause of otitis media. This study aims to increase awareness on the clinical presentation of TB otitis media and illustrate how early detection affects treatment outcome. Chart review of 12 patients (13 ears) from a tertiary hospital in Manila, Philippines, seen from 2004 to 2009. Clinical predictors of the disease were summarized. Clinical, radiologic, and audiometric outcomes after treatment were compared between treatment groups. The 5 otoscopic presentations were multiple perforations, single perforation with refractory otorrhea and exuberant granulation tissue formation, single perforation with minimal otorrhea and no granulation tissue formation, intact tympanic membrane with middle ear effusion, and intact tympanic membrane with tumorlike tissue in the middle ear. Clinical predictors of the disease were history of pulmonary TB, work-related contamination of the infection, positive purified protein derivative test, positive chest radiographic finding and intraoperative granulation tissue with cheesy material, and temporal bone computed tomographic scan findings. Patients who had no middle ear surgery showed significantly better clinical, radiologic, and audiometric outcomes than those who were diagnosed late and had more complicated surgical procedure. The clinical presentation of TB otitis media is variable. Early detection of the early forms entail less surgical intervention and favors better treatment results.
The evolution of radiology from paraclinical to clinical.
Boey, Hong Khim
2009-07-01
The perception of Radiology in the early 60s as paraclinical stems from the poor image the clinicians had for our limited resources in providing only plain fi lm studies, VIPs and the single contrast barium studies which exclude only gross lesions. The evolution to clinical status started as early as the mid 60s. My personal recollection and reflection of the histological events that took place covered here highlights the reasons for the transformation from paraclinical to clinical and these form the main theme for this paper. Radiologists' professionalism plays an infinite part in the evolution to clinical Radiology. Rapid technological advances in imaging help to propel Radiology to the forefront. But credit must go to the individual Radiologist for their personal efforts and contributions. Reflection on past events of Radiology in Singapore leading to the establishment of Clinical Radiology was presented. The future of Radiology is brought up for discussion on the role of Radiologists with reference to subspecialisation necessitated by the ever increasing advances in Medical Imaging and demand for Interventional Radiology.
Chicaíza-Becerra, Liliana Alejandra; García-Molina, Mario; Gamboa, Óscar
2012-06-01
Contrast media can cause acute renal failure by direct toxic effects on the tubular cells and kidney ischemia. Diabetics and hospitalized patients have a greater risk of developing contrast-induced nephropathy than the general population. The cost effectiveness of iso and low-osmolality contrast media was assessed in high risk outpatients. The analysis was based on a systematic literature review comparing the nephrotoxic effects of iso- to low-osmolality contrast media. Only direct costs were considered; these were obtained from the official tariff manual. Incremental cost-effectiveness ratios, efficiency curves and acceptability curves were calculated. Univariate sensitivity analyses were performed for costs and effects, as well as probabilistic analyses. Zero and 3% discounts were applied to results. The cost-effectiveness threshold was equal to the per capita GDP per life-year gained. Alternatives with Iopamidol and Iodixanol are preferable to the others, because both reduce risk of contrast-induced nephropathy and are less costly. The incremental cost-effectiveness of the Iodixanol alternative compared to the Iopamidol alternative is US$ 14,660 per additional life year gained; this is more than twice the threshold. The low-osmolality contrast medium, Iopamidol, appears to be cost-effective when compared with Iohexol or other low-osmolality contrast media (Iopromide, Iobitridol, Iomeprol, Iopentol and Ioxilan) in contrast-induced nephropathy, high-risk outpatients. The choice of the iso-osmolality contrast medium, Iodixanol, depends on its cost per vial and on the willingness to pay.
Acute kidney injury by radiographic contrast media: pathogenesis and prevention.
Andreucci, Michele; Faga, Teresa; Pisani, Antonio; Sabbatini, Massimo; Michael, Ashour
2014-01-01
It is well known that iodinated radiographic contrast media may cause kidney dysfunction, particularly in patients with preexisting renal impairment associated with diabetes. This dysfunction, when severe, will cause acute renal failure (ARF). We may define contrast-induced Acute Kidney Injury (AKI) as ARF occurring within 24-72 hrs after the intravascular injection of iodinated radiographic contrast media that cannot be attributed to other causes. The mechanisms underlying contrast media nephrotoxicity have not been fully elucidated and may be due to several factors, including renal ischaemia, particularly in the renal medulla, the formation of reactive oxygen species (ROS), reduction of nitric oxide (NO) production, and tubular epithelial and vascular endothelial injury. However, contrast-induced AKI can be prevented, but in order to do so, we need to know the risk factors. We have reviewed the risk factors for contrast-induced AKI and measures for its prevention, providing a long list of references enabling readers to deeply evaluate them both.
Acute Kidney Injury by Radiographic Contrast Media: Pathogenesis and Prevention
Faga, Teresa; Pisani, Antonio; Michael, Ashour
2014-01-01
It is well known that iodinated radiographic contrast media may cause kidney dysfunction, particularly in patients with preexisting renal impairment associated with diabetes. This dysfunction, when severe, will cause acute renal failure (ARF). We may define contrast-induced Acute Kidney Injury (AKI) as ARF occurring within 24–72 hrs after the intravascular injection of iodinated radiographic contrast media that cannot be attributed to other causes. The mechanisms underlying contrast media nephrotoxicity have not been fully elucidated and may be due to several factors, including renal ischaemia, particularly in the renal medulla, the formation of reactive oxygen species (ROS), reduction of nitric oxide (NO) production, and tubular epithelial and vascular endothelial injury. However, contrast-induced AKI can be prevented, but in order to do so, we need to know the risk factors. We have reviewed the risk factors for contrast-induced AKI and measures for its prevention, providing a long list of references enabling readers to deeply evaluate them both. PMID:25197639
Lasnon, Charline; Quak, Elske; Briand, Mélanie; Gu, Zheng; Louis, Marie-Hélène; Aide, Nicolas
2013-01-17
The use of iodinated contrast media in small-animal positron emission tomography (PET)/computed tomography (CT) could improve anatomic referencing and tumor delineation but may introduce inaccuracies in the attenuation correction of the PET images. This study evaluated the diagnostic performance and accuracy of quantitative values in contrast-enhanced small-animal PET/CT (CEPET/CT) as compared to unenhanced small animal PET/CT (UEPET/CT). Firstly, a NEMA NU 4-2008 phantom (filled with 18F-FDG or 18F-FDG plus contrast media) and a homemade phantom, mimicking an abdominal tumor surrounded by water or contrast media, were used to evaluate the impact of iodinated contrast media on the image quality parameters and accuracy of quantitative values for a pertinent-sized target. Secondly, two studies in 22 abdominal tumor-bearing mice and rats were performed. The first animal experiment studied the impact of a dual-contrast media protocol, comprising the intravenous injection of a long-lasting contrast agent mixed with 18F-FDG and the intraperitoneal injection of contrast media, on tumor delineation and the accuracy of quantitative values. The second animal experiment compared the diagnostic performance and quantitative values of CEPET/CT versus UEPET/CT by sacrificing the animals after the tracer uptake period and imaging them before and after intraperitoneal injection of contrast media. There was minimal impact on IQ parameters (%SDunif and spillover ratios in air and water) when the NEMA NU 4-2008 phantom was filled with 18F-FDG plus contrast media. In the homemade phantom, measured activity was similar to true activity (-0.02%) and overestimated by 10.30% when vials were surrounded by water or by an iodine solution, respectively. The first animal experiment showed excellent tumor delineation and a good correlation between small-animal (SA)-PET and ex vivo quantification (r2 = 0.87, P < 0.0001). The second animal experiment showed a good correlation between CEPET/CT and UEPET/CT quantitative values (r2 = 0.99, P < 0.0001). Receiver operating characteristic analysis demonstrated better diagnostic accuracy of CEPET/CT versus UEPET/CT (senior researcher, area under the curve (AUC) 0.96 versus 0.77, P = 0.004; junior researcher, AUC 0.78 versus 0.58, P = 0.004). The use of iodinated contrast media for small-animal PET imaging significantly improves tumor delineation and diagnostic performance, without significant alteration of SA-PET quantitative accuracy and NEMA NU 4-2008 IQ parameters.
Are gadolinium-based contrast media nephrotoxic? A renal biopsy study.
Akgun, Hulya; Gonlusen, Gulfiliz; Cartwright, Joiner; Suki, Wadi N; Truong, Luan D
2006-09-01
Gadolinium-based contrast media were originally introduced as alternatives to iodinated media for magnetic resonance imaging. Although originally thought to be nonnephrotoxic, gadolinium-based contrast media have recently been reported to be associated with acute renal failure; the mechanism and the underlying renal injury are not completely understood. We report what is, to our knowledge, the first renal biopsy in this context. A 56-year-old patient underwent 2 consecutive vascular imaging procedures in conjunction with gadolinium-based contrast medium administration. A few days later, the patient developed acute renal failure. A renal biopsy showed acute tubular cell injury including patchy tubular cell necrosis, tubular cell degeneration, and marked proliferation of tubular cells, together with mild interstitial edema and interstitial inflammation, but without significant glomerular or vascular changes. During supportive therapy, renal function was partially regained. This case emphasizes the potential nephrotoxicity of gadolinium-based contrast media and suggests that the nephrotoxicity is related to potentially reversible acute tubular cell injury.
[Relevance of contrast ultrasound with microbubbles in vascular medecine].
Erdmann, Andreas; Ney, Barbara; Alatri, Adriano; Calanca, Luca; Mazzolai, Lucia
2016-12-07
Application of ultrasound contrast media has become a standard in diagnostic imaging in cardiology and in the characterization of focal lesions in multiple organs, especially of the liver. In the past years there was a growing body of evidence for their usefulness in vascular medicine. The development of contrast media, microbubbles with a stabilizing envelope and filled with gaz, small enough to pass through pulmonary capillaries made real-time imaging of organ perfusion possible. Ultrasound contrast media are rapidly eliminated by exhalation and can safely be administered to patients with renal failure. The objective of this review is to describe the basic principles of ultrasound contrast imaging and to inform about vascular applications of contrast ultrasound.
Hwang, Eui Jin; Shin, Cheong-Il; Choi, Young Hun; Park, Chang Min
2018-06-06
To evaluate the frequency, outcome, and risk factors of intravenous contrast media (CM) extravasation during contrast-enhanced CT scans in a large population. After institutional review board approval, 142,651 patients (72,976 males and 69,675 females; mean age, 59.9 ± 13.0 years) who underwent contrast-enhanced CT scans with intravenous CM between January 2015 and April 2017 were retrospectively included. The frequency of CM extravasations and their clinical outcomes were investigated. Risk factors of CM extravasation were evaluated using logistic regression with generalized estimating equation analyses. In addition, the frequency and risk factors of large-volume (≥100 ml) CM extravasation were also investigated. CM extravasation occurred in 0.23% (321/142,651) of patients, all of which were of mild degree and resolved without any sequelae through conservative management. Multivariate analysis revealed that female gender [odds ratio (OR) = 1.61; p < 0.001], 60 < age ≤ 70 years (OR = 1.71; p = 0.004) or age > 70 years (OR = 2.49; p < 0.001), patients in general wards (OR = 2.71; p < 0.001) or ICUs (OR = 4.76; p < 0.001), 9.4 < CM viscosity ≤ 10.0 (OR = 1.65; p = 0.015), 10.0 < CM viscosity ≤ 10.6 (OR = 1.60; p = 0.002), and CM viscosity > 16.0 (OR = 2.55, p < 0.001) were independent risk factors for CM extravasation. CM extravasation during contrast-enhanced CT scans was uncommon with no substantial clinical consequences. Several risk factors that may have the potential to reduce the occurrence of CM extravasation were identified. • The observed frequency of contrast media extravasation during contrast-enhanced CT scans was 0.23% (321/142,651). • Significant risk factors for contrast media extravasation were female gender, age older than 60 years, patients in general wards or ICUs, and the viscosity of contrast media greater than 9.4 mPa∙s. • The main preventive action for contrast media extravasation would be to lower the viscosity of contrast media.
Kotter, Elmar; Bley, Thorsten A; Saueressig, Ulrich; Fisch, Dagmar; Springer, Oliver; Winterer, Jan Torsten; Schaefer, Oliver; Langer, Mathias
2003-11-01
To evaluate the detection rate of fine details of a new thin-film transistor (TFT) grayscale monitor designed for radiologic diagnosis, compared with a type of cathode ray tube (CRT) screen used routinely for diagnostic radiology. Fifteen radiographs of a statistical phantom presenting low- and high-contrast details were obtained and read out with an Agfa ADC compact storage phosphor system. Each radiograph presented 60 high-density (high-contrast) and 60 low-density (low-contrast) test bodies. Approximately half the test bodies contained holes with different diameters. Observers were asked to detect the presence or absence of a hole in the test body on a 5-point confidence range. The total of 1800 test bodies was reviewed by 5 radiologists on the TFT monitor (20.8 inches; 1536 x 2048 pixels; maximum luminance, 650 cd/m2; contrast, 600:1) and the CRT monitor (21 inches; P45 Phosphor; 2048 x 2560 pixels operated at 1728 x 2304 pixels; maximum luminance, 600 cd/m2; contrast, 300:1). The data were analyzed by receiver-operator characteristic analysis. For high-contrast details, the mean area under the curve rated 0.9336 for the TFT monitor and 0.9312 for the CRT monitor. For low-contrast details, the mean area under the curve rated 0.9189 for the TFT monitor and 0.9224 for the CRT monitor. At P
Immediate and delayed reactions to radiocontrast media: is there an allergic mechanism?
Brockow, Knut
2009-08-01
Radiocontrast media can cause immediate (1 hour) and nonimmediate (>1 hour) hypersensitivity reactions that remain unpredictable and a cause of concern for radiologists and cardiologists. Immediate hypersensitivity reactions resemble anaphylaxis, whereas nonimmediate ones clinically are predominated by exanthemas. Increasing evidence indicates that immediate reactions and nonimmediate skin exanthemas may be allergic reactions involving either contrast media-reactive IgE or T cells, respectively. Skin testing is a useful tool for the diagnosis of contrast media allergy. It may have an important role in the selection of a safe product in previous reactors, although validation data are still lacking. In vitro tests to search for contrast media-specific cell activation are currently under investigation.
Using Twitter for Teaching and Learning in an Oral and Maxillofacial Radiology Course.
Gonzalez, Shawneen M; Gadbury-Amyot, Cynthia C
2016-02-01
The aim of this study was to describe the implementation of one form of social media (Twitter) in an oral radiology course and evaluate dental students' use and perceptions of this technology for teaching and learning. An author-developed questionnaire was used to solicit second-year students' knowledge, use, and perceptions of Twitter for teaching and learning in an oral radiology course at one U.S. dental school. A combination of Likert scales, multiple allowable answers, and an open-ended comment question was employed. The questionnaire was piloted in spring 2010 followed by data collection in spring 2011. Out of 45 students, 40 (88.9%) completed the questionnaire. Of the respondents, 95% reported having not used Twitter prior to their second year of dental school; 55% of them created an account for the course. The top two reasons they gave for creating an account were viewing radiographic examples and staying informed about questions and answers that were posted. The top two reasons they gave for not creating an account were that the content was viewable online without an account and not wanting another online account. The students perceived the Twitter sessions as helpful and reported it improved accessibility to the instructor. The results of this study challenged the assumption that dental students are well versed in all forms of social media, but overall, these students agreed that the use of Twitter had enhanced the learning environment in the radiology course.
Endoscopy versus radiology in post-procedural monitoring after peroral endoscopic myotomy (POEM).
Nast, Jan Friso; Berliner, Christoph; Rösch, Thomas; von Renteln, Daniel; Noder, Tania; Schachschal, Guido; Groth, Stefan; Ittrich, Harald; Kersten, Jan F; Adam, Gerhard; Werner, Yuki B
2018-03-15
The newly developed technique of peroral endoscopic myotomy (POEM) has been shown to be effective in several short- and mid-term studies. Limited information is available about the adequacy of immediate post-POEM monitoring tests. POEM was performed under general anesthesia in 228 patients (59.6% male, mean age 45.6 ± 15.5 years). Post-procedural checks comprised clinical and laboratory examination, and, during post-procedure days 1-5, endoscopy and-in the first 114 cases-radiologic examination using water-soluble contrast (1st group); the remaining patients underwent post-procedure controls without radiology (2nd group). Main outcome was value of endoscopic compared to radiologic control for recognition of early adverse events. In the first group, routine fluoroscopic contrast swallow suggested minor leakages at the mucosal entry site in two cases which was confirmed endoscopically in only one. Endoscopy revealed two minor entry site leakages and, in six additional cases, dislocated clips without leakage (overall 5.3%). All eight patients underwent reclipping and healed without clinical sequelae. In the 2nd group, endoscopy showed 5 clip dislocations (all reclipped) and one ischemic cardiac perforation in a patient with clinical deterioration on post-POEM day 1 who had to undergo surgery after confirmation of leakage by CT. Radiologic monitoring (contrast swallow) after POEM is not useful and can be omitted. Even routine endoscopic monitoring for detection and closure of minor defects of the mucosal entry site yields limited information with regards to final outcome; major complications are very rare and probably associated with clinical deterioration. Clinical Trials Gov Registration number of the main study: NCT01405417.
Value of MR contrast media in image-guided body interventions.
Saeed, Maythem; Wilson, Mark
2012-01-28
In the past few years, there have been multiple advances in magnetic resonance (MR) instrumentation, in vivo devices, real-time imaging sequences and interventional procedures with new therapies. More recently, interventionists have started to use minimally invasive image-guided procedures and local therapies, which reduce the pain from conventional surgery and increase drug effectiveness, respectively. Local therapy also reduces the systemic dose and eliminates the toxic side effects of some drugs to other organs. The success of MR-guided procedures depends on visualization of the targets in 3D and precise deployment of ablation catheters, local therapies and devices. MR contrast media provide a wealth of tissue contrast and allows 3D and 4D image acquisitions. After the development of fast imaging sequences, the clinical applications of MR contrast media have been substantially expanded to include pre- during- and post-interventions. Prior to intervention, MR contrast media have the potential to localize and delineate pathologic tissues of vital organs, such as the brain, heart, breast, kidney, prostate, liver and uterus. They also offer other options such as labeling therapeutic agents or cells. During intervention, these agents have the capability to map blood vessels and enhance the contrast between the endovascular guidewire/catheters/devices, blood and tissues as well as direct therapies to the target. Furthermore, labeling therapeutic agents or cells aids in visualizing their delivery sites and tracking their tissue distribution. After intervention, MR contrast media have been used for assessing the efficacy of ablation and therapies. It should be noted that most image-guided procedures are under preclinical research and development. It can be concluded that MR contrast media have great value in preclinical and some clinical interventional procedures. Future applications of MR contrast media in image-guided procedures depend on their safety, tolerability, tissue specificity and effectiveness in demonstrating success of the interventions and therapies.
Torsten Almén (1931-2016): the father of non-ionic iodine contrast media.
Nyman, Ulf; Ekberg, Olle; Aspelin, Peter
2016-09-01
The Swedish radiologist Torsten Almén is the first clinical radiologist ever to have made a fundamental contribution to intravascular contrast medium design, the development of non-ionic contrast media. He became emotionally triggered by the patients' severe pain each time he injected the ionic "high-osmolar" contrast media when performing peripheral arteriographies in the early 1960s. One day he got a flash of genius that combined the observation of pain, a pathophysiological theory and how to eliminate it with suitable contrast media chemistry. After self-studies in chemistry he developed the concept of iodine contrast media not dissociating into ions in solution to reduce their osmolality and even reach plasma isotonicity. He offered several pharmaceutical companies his concept of mono- and polymeric non-ionic agents but without response, since it was considered against the chemical laws of that time. Contrast media constructed as salts and dissociating into ions in solution was regarded an absolute necessity to achieve high enough water solubility and concentration for diagnostic purposes. Finally a small Norwegian company, Nyegaard & Co., took up his idea 1968 and together they developed the essentially painless "low-osmolar" monomeric non-ionic metrizamide (Amipaque) released in 1974 and iohexol (Omipaque) in 1982 followed by the "iso-osmolar" dimeric non-ionic iodixanol (Visipaque) released in 1993. This has implied a profound paradigm shift with regard to reduction of both hypertonic and chemotoxic side effects, which have been a prerequisite for the today's widespread use of contrast medium-enhanced CT and advanced endovascular interventional techniques even in fragile patients. © The Foundation Acta Radiologica 2016.
Eng, John; Wilson, Renee F; Subramaniam, Rathan M; Zhang, Allen; Suarez-Cuervo, Catalina; Turban, Sharon; Choi, Michael J; Sherrod, Cheryl; Hutfless, Susan; Iyoha, Emmanuel E; Bass, Eric B
2016-03-15
Iodine contrast media are essential components of many imaging procedures. An important potential side effect is contrast-induced nephropathy (CIN). To compare CIN risk for contrast media within and between osmolality classes in patients receiving diagnostic or therapeutic imaging procedures. PubMed, EMBASE, Cochrane Library, Clinical Trials.gov, and Scopus through June 2015. Randomized, controlled trials that reported CIN-related outcomes in patients receiving low-osmolar contrast media (LOCM) or iso-osmolar contrast media for imaging. Independent study selection and quality assessment by 2 reviewers and dual extraction of study characteristics and results. None of the 5 studies that compared types of LOCM reported a statistically significant or clinically important difference among study groups, but the strength of evidence was low. Twenty-five randomized, controlled trials found a slight reduction in CIN risk with the iso-osmolar contrast media agent iodixanol compared with a diverse group of LOCM that just reached statistical significance in a meta-analysis (pooled relative risk, 0.80 [95% CI, 0.65 to 0.99]; P = 0.045). This comparison's strength of evidence was moderate. In a meta regression of randomized, controlled trials of iodixanol, no relationship was found between route of administration and comparative CIN risk. Few studies compared LOCM. Procedural details about contrast administration were not uniformly reported. Few studies specified clinical indications or severity of baseline renal impairment. No differences were found in CIN risk among types of LOCM. Iodixanol had a slightly lower risk for CIN than LOCM, but the lower risk did not exceed a criterion for clinical importance. Agency for Healthcare Research and Quality.
Clinical and subclinical leaks after low colorectal anastomosis: a clinical and radiologic study.
Lim, Michael; Akhtar, Saleem; Sasapu, Kishore; Harris, Keith; Burke, Dermot; Sagar, Peter; Finan, Paul
2006-10-01
This study was designed to examine the natural history of subclinical leaks and their effect on bowel function and quality of life and to evaluate water-soluble contrast enema features that predict anastomotic healing after leaks. Consecutive patients who underwent low rectal anastomosis were followed up postoperatively for leaks. All leaks were confirmed radiologically with CT scanning and water-soluble contrast enema imaging. Water-soluble contrast enemas were serially repeated to identify healing. Characteristics on initial water-soluble contrast enema were correlated with observed healing. Postoperatively, patients were required to fill in a quality of life and a bowel function questionnaire. A total of 138 patients underwent low rectal anastomosis procedures with a median follow-up period of 26 (interquartile range, 19-37) months. There were 23 documented leaks of which 13 (9 percent) presented clinically and 10 (8 percent) presented subclinically. Ileostomy closure was possible in 4 of 13 (30 percent) patients with a clinical leak and all 10 (100 percent) patients with a subclinical leak. Median quality of life scores were lower for patients with clinical leaks and no ileostomy closure (P = 0.03). Bowel function for subclinical leak patients and clinical leak patients with ileostomy closure were similarly impaired. The presence of a cavity (P = 0.01) and a stricture (P = 0.01) at the anastomotic site were unfavorable radiologic features associated with nonhealing. Subclinical leaks are more benign in their natural history compared with clinical leaks. Quality of life and bowel function is no better in patients with a subclinical leak compared with patients with a clinical leak who have ileostomy closure. Anastomotic leaks may resolve if favorable radiologic features are present.
Varela, O; Melone, A; López-Menchaca, R; Sevilla, R; Callejo, D; López-Álvarez, S; Román Fernández, A; García, S; Mantilla, I; Zaballos, M
2018-06-07
Interfascial blocks of the thoracic wall are being developed as an alternative to central blocks in breast surgery. However, there are few studies that have evaluated the anatomical extension of the local anaesthetic. The objective of this study was to analyse, using fluoroscopy, the spreading of two volumes (10 vs. 20ml) of radiological contrast in the serratus-intercostal plane block in an experimental pig model. Ten Large-White breed pigs were selected to have a bilateral ultrasound serratus-intercostal plane block performed, with the administering of 10ml and 20ml of iopamidol in the right and left hemithorax, respectively. The spreading of contrast was analysed by fluoroscopy. The Spearman test correlation was used to evaluate the relationship between the administered volume and radiological spreading. A value of P<.05 was considered significant. Twenty anaesthetic blocks were performed, being able to analyse 18 of them. The administration of 10ml of contrast was associated with a mean spreading of 2.28±0.31 (95% CI; 2.01-2.54) intercostal spaces, while the administration of 20ml showed a spreading of 3±0.25 (95% CI; 2.81-3.18) intercostal spaces. There was a significant correlation between the injected volume and the spreading of the contrast (Spearman correlation coefficient of 0.81; P=.0001). The results showed a spreading of volume subject to the serratus-intercostal plane block, although not maintaining a 1:1 ratio. Doubling the volume increased the blocked segments by 31%. These findings, if corroborated in the clinical practice, would allow a more precise adjustment in the anaesthetic volume administered. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Gould, Richard; McFadden, Sonyia L; Horn, Simon; Prise, Kevin M; Doyle, Philip; Hughes, Ciara M
2016-01-01
Paediatric cardiac catheterizations may result in the administration of substantial amounts of iodinated contrast media and ionizing radiation. The aim of this work was to investigate the effect of iodinated contrast media in combination with in vitro and in vivo X-ray radiation on lymphocyte DNA. Six concentrations of iodine (15, 17.5, 30, 35, 45, and 52.5 mg of iodine per mL blood) represented volumes of iodinated contrast media used in the clinical setting. Blood obtained from healthy volunteers was mixed with iodinated contrast media and exposed to radiation doses commonly used in paediatric cardiac catheterizations (0 mGy, 70 mGy, 140 mGy, 250 mGy and 450 mGy). Control samples contained no iodine. For in vivo experimentation, pre and post blood samples were collected from children undergoing cardiac catheterization, receiving iodine concentrations of up to 51 mg of iodine per mL blood and radiation doses of up to 400 mGy. Fluorescence microscopy was performed to assess γH2AX-foci induction, which corresponded to the number of DNA double-strand breaks. The presence of iodine in vitro resulted in significant increases of DNA double-strand breaks beyond that induced by radiation for ≥ 17.5 mg/mL iodine to blood. The in vivo effects of contrast media on children undergoing cardiac catheterization resulted in a 19% increase in DNA double-strand breaks in children receiving an average concentration of 19 mg/mL iodine to blood. A larger investigation is required to provide further information of the potential benefit of lowering the amount of iodinated contrast media received during X-ray radiation investigations. Copyright © 2015 John Wiley & Sons, Ltd.
Advances in equine computed tomography and use of contrast media.
Puchalski, Sarah M
2012-12-01
Advances in equine computed tomography have been made as a result of improvements in software and hardware and an increasing body of knowledge. Contrast media can be administered intravascularly or intrathecally. Contrast media is useful to differentiate between tissues of similar density. Equine computed tomography can be used for many different clinical conditions, including lameness diagnosis, fracture identification and characterization, preoperative planning, and characterization of skull diseases. Copyright © 2012 Elsevier Inc. All rights reserved.
Contrast Media: Are There Differences in Nephrotoxicity among Contrast Media?
2014-01-01
Iodinated contrast agents are usually classified based upon their osmolality—high, low, and isosmolar. Iodinated contrast agents are also nephrotoxic in some but not all patients resulting in loss of glomerular filtration rate. Over the past 30 years, nephrotoxicity has been linked to osmolality although the precise mechanism underlying such a link has been elusive. Improvements in our understanding of the pathogenesis of nephrotoxicity and prospective randomized clinical trials have attempted to further explore the relationship between osmolality and nephrotoxicity. In this review, the basis for our current understanding that there are little if any differences in nephrotoxic potential between low and isosmolar contrast media will be detailed using data from clinical studies. PMID:24587997
Professional Social Networking in Radiology: Who Is There and What Are They Doing?
Patel, Sumir S; Hawkins, C Matthew; Rawson, James V; Hoang, Jenny K
2017-05-01
Although it is perceived that the use of social media professionally is increasing among radiologists, little is known about the habits and demographics of this subspecialty. This study aims to compare radiologists who use social networking for professional purposes to those who do not with regard to their characteristics, habits, and attitudes. Radiologists were invited by e-mail and through posts on social networks to participate in a survey on the use of social media platforms. Questions included type of user, pattern of use, and benefits and barriers. Professional users and professional nonusers were compared. One hundred eighty-six radiologists responded. One hundred ten (59.1%) used social networking for professional purposes, 34 (18.2%) for personal-use only, and 42 (22.6%) denied using social media. LinkedIn was the most common platform among all professional users, and Twitter was the most commonly used platform among highly active professional users. Trainees comprised 52 out of 110 (47.3%) professional social networking users compared to 18 out of 76 (23.7%) nonusers (P < 0.01). A subgroup analysis on Twitter use for professional purposes revealed a significant gender difference: 15 out of 66 (22.7%) professional Twitter users were female compared to 48 out of 120 (40.0%) non-Twitter users (P < 0.05). The greatest barrier to professional social media use for nonusers was confidentiality. Nearly 60% of radiologist respondents use social networking for professional purposes. Radiology is likely to see growth in the role of social networking in the coming years as nearly half of professional users are radiology trainees. Twitter use for professional purposes among radiologists was disproportionately male. It is important to be cognizant of gender imbalance and to improve visibility of female leaders on social networking. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Canga, Ana; Kislikova, Maria; Martínez-Gálvez, María; Arias, Mercedes; Fraga-Rivas, Patricia; Poyatos, Cecilio; de Francisco, Angel L M
2014-01-01
Nephrogenic systemic fibrosis is a fibrosing disorder that affects patients with impaired renal function and is associated with the administration of gadolinium-based contrast media used in MRI. Despite being in a group of drugs that were considered safe, report about this potentially serious adverse reaction was a turning point in the administration guidelines of these contrast media. There has been an attempt to establish safety parameters to identify patients with risk factors of renal failure. The close pharmacovigilance and strict observation of current regulations, with special attention being paid to the value of glomerular filtration, have reduced the published cases involving the use of gadolinium-based contrast media. In a meeting between radiologists and nephrologists we reviewed the most relevant aspects currently and recommendations for its prevention.
Mabry, Christian; Yandle, Gretchen; Erbil, Jen; Happel, Kyle; Neitzschman, Harold R
2014-01-01
A 61-year-old male with a past medical history of chronic, uncontrolled hypertension received a non-contrasted computed tomogram (CT) of the chest and abdomen to investigate for possible Conn syndrome. This noncontrast study showed some areas of nodularity around the vertebral bodies bilaterally and extending into the posterior mediastinal region. A CT of the chest with intravenous contrast, and 3D reconstruction were then obtained.
Basic MR relaxation mechanisms and contrast agent design.
De León-Rodríguez, Luis M; Martins, André F; Pinho, Marco C; Rofsky, Neil M; Sherry, A Dean
2015-09-01
The diagnostic capabilities of magnetic resonance imaging (MRI) have undergone continuous and substantial evolution by virtue of hardware and software innovations and the development and implementation of exogenous contrast media. Thirty years since the first MRI contrast agent was approved for clinical use, a reliance on MR contrast media persists, largely to improve image quality with higher contrast resolution and to provide additional functional characterization of normal and abnormal tissues. Further development of MR contrast media is an important component in the quest for continued augmentation of diagnostic capabilities. In this review we detail the many important considerations when pursuing the design and use of MR contrast media. We offer a perspective on the importance of chemical stability, particularly kinetic stability, and how this influences one's thinking about the safety of metal-ligand-based contrast agents. We discuss the mechanisms involved in MR relaxation in the context of probe design strategies. A brief description of currently available contrast agents is accompanied by an in-depth discussion that highlights promising MRI contrast agents in the development of future clinical and research applications. Our intention is to give a diverse audience an improved understanding of the factors involved in developing new types of safe and highly efficient MR contrast agents and, at the same time, provide an appreciation of the insights into physiology and disease that newer types of responsive agents can provide. © 2015 Wiley Periodicals, Inc.
"Basic MR Relaxation Mechanisms & Contrast Agent Design"
De León-Rodríguez, Luis M.; Martins, André F.; Pinho, Marco; Rofsky, Neil; Sherry, A. Dean
2015-01-01
The diagnostic capabilities of magnetic resonance imaging (MRI) have undergone continuous and substantial evolution by virtue of hardware and software innovations and the development and implementation of exogenous contrast media. Thirty years since the first MRI contrast agent was approved for clinical use, a reliance on MR contrast media persists largely to improve image quality with higher contrast resolution and to provide additional functional characterization of normal and abnormal tissues. Further development of MR contrast media is an important component in the quest for continued augmentation of diagnostic capabilities. In this review we will detail the many important considerations when pursuing the design and use of MR contrast media. We will offer a perspective on the importance of chemical stability, particularly kinetic stability, and how this influences one's thinking about the safety of metal-ligand based contrast agents. We will discuss the mechanisms involved in magnetic resonance relaxation in the context of probe design strategies. A brief description of currently available contrast agents will be accompanied by an in-depth discussion that highlights promising MRI contrast agents in development for future clinical and research applications. Our intention is to give a diverse audience an improved understanding of the factors involved in developing new types of safe and highly efficient MR contrast agents and, at the same time, provide an appreciation of the insights into physiology and disease that newer types of responsive agents can provide. PMID:25975847
Life-Threatening Thrombocytopenia Following Intravenous Contrast Media Infusion
Kim, Minjeong; Park, Jisun
2018-01-01
Radiocontrast media-induced acute severe thrombocytopenia is a very rare complication and potentially life-threatening. Here, we report the case of a 63-year-old male patient with severe acute thrombocytopenia following first exposure to intravenous non-ionic contrast media without immediate allergic reactions. His platelet count dropped from 107000/µL to 2000/µL after six hours of radiocontrast infusion. After administration of corticosteroid and transfusion of platelet concentrates, the platelet count returned gradually to normal within 5 days. To the best of our knowledge, non-ionic contrast media-induced isolated acute severe thrombocytopenia following no signs or symptoms of immediate allergic reaction has never been described. PMID:29214792
Vontobel, Jan; Possner, Mathias; Schütz, Philipp; Müller, Beat; Taramasso, Maurizio; Binder, Roland K; Haueis, Sabine; Attinger-Toller, Adrian; Maisano, Francesco; Nietlispach, Fabian
2015-01-01
The study objective was to evaluate the impact of the amount of contrast medium used for transcatheter aortic valve implantation (TAVI) on short-term outcome. Patients undergoing TAVI are exposed to repeat contrast medium application both for preprocedural screening and during the TAVI procedure itself. Whether the amount of contrast media is associated with worse outcome is unclear. A total of 257 patients were included (median age 82.7 years) and divided into two groups with preserved and reduced kidney function (glomerular filtration rate <60 ml/min/1.73 m2), respectively. Total volume of contrast media administered during and within 5 days prior to TAVI was analysed. A combined early safety endpoint at 30 days was evaluated. The early safety endpoint was reached by 31 patients and acute kidney injury occurred in 22 patients. The median total volume of contrast media administered was 144 ml (interquartile range 81-225 ml). The amount of contrast did not independently predict the early safety endpoint in the overall population (odds ratio [OR] 0.93, 95% confidence interval [CI] 0.56 to 1.53, p = 0.774) and in subgroups with preserved and reduced kidney function. Change in creatinine was an independent strong predictor of the early safety endpoint in the overall population (OR 18.13, 95% CI 4.70 to 69.99, p <0.001), as well as in subgroups with preserved and reduced kidney function. The amount of contrast did not predict a change in creatinine within 72 hours following TAVI (r = 0.02, 95% CI -0.02 to 0.07, p = 0.368). Decreased kidney function after TAVI influences outcome. When rather small amounts of contrast media are used for screening and the TAVI procedure itself, the amount of contrast media seems not to be an independent predictor of outcome, further suggesting that decreased kidney function after TAVI is multifactorial.
Lääperi, A L
1996-01-01
The purpose of this study was to analyse the cost structure of radiological procedures in the intermediary referral hospitals and general practice and to develop a cost accounting system for radiological examinations that takes into consideration all relevant cost factors and is suitable for management of radiology departments and regional planning of radiological resources. The material comprised 174,560 basic radiological examinations performed in 1991 at 5 intermediate referral hospitals and 13 public health centres in the Pirkanmaa Hospital District in Finland. All radiological departments in the hospitals were managed by a specialist in radiology. The radiology departments at the public health care centres operated on a self-referral basis by general practitioners. The data were extracted from examination lists, inventories and balance sheets; parts of the data were estimated or calculated. The radiological examinations were compiled according to the type of examination and equipment used: conventional, contrast medium, ultrasound, mammography and roentgen examinations with mobile equipment. The majority of the examinations (87%) comprised conventional radiography. For cost analysis the cost items were grouped into 5 cost factors: personnel, equipment, material, real estate and administration costs. The depreciation time used was 10 years for roentgen equipment, 5 years for ultrasound equipment and 5 to 10 years for other capital goods. An annual interest rate of 10% was applied. Standard average values based on a sample at 2 hospitals were used for the examination-specific radiologist time, radiographer time and material costs. Four cost accounting versions with varying allocation of the major cost items were designed. Two-way analysis of variance of the effect of different allocation methods on the costs and cost structure of the examination groups was performed. On the basis of the cost analysis a cost accounting program containing both monetary and nonmonetary variables was developed. In it the radiologist, radiographer and examination-specific equipment costs were allocated to the examinations applying estimated cost equivalents. Some minor cost items were replaced by a general cost factor (GCF). The program is suitable for internal cost accounting of radiological departments as well as regional planning. If more accurate cost information is required, cost assignment employing the actual consumption of the resources and applying the principles of activity-based cost accounting is recommended. As an application of the cost accounting formula the average costs of the radiological examinations were calculated. In conventional radiography the average proportion of the cost factors in the total material was: personnel costs 43%, equipment costs 26%, material costs 7%, real estate costs 11%, administration and overheads 14%. The average total costs including radiologist costs in the hospitals were (FIM): conventional roentgen examinations 188, contrast medium examinations 695, ultrasound 296, mammography 315, roentgen examinations with mobile equipment 1578. The average total costs without radiologist costs in the public health centres were (FIM): conventional roentgen examinations 107, contrast medium examinations 988, ultrasound 203, mammography 557. The average currency rate of exchange in 1991 was USD 1 = FIM 4.046. The following formula is proposed for calculating the cost of a radiological examination (or a group of examinations) performed with a certain piece of equipment during a period of time (e.g. 1 year): a2/ sigma ax*ax+ b2/ sigma bx*bx+ d1/d5*dx+ e1 + [(c1+ c2) + d4 + (e2 - e3) + f5 + g1+ g2+ i]/n.
Compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media.
Sarakbi, Iman; Krämer, Irene
2016-12-01
The aim of this study was to determine the compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media over a period of seven days when stored light protected under refrigerated conditions. DC bead™ (2 ml) (Biocompatibles UK Ltd) of the bead size 70-150 µm ( = DC bead M1) or bead size 100-300 µm were loaded with 75 mg epirubicin powder formulation (Farmorubicin® dissolved in 3 ml water for injection to a concentration of 25 mg/ml) or 76 mg epirubicin injection solution (Epimedac® 2 mg/ml) within 2 h or 6 h, respectively. After removal of the excess solution, the epirubicin-loaded beads were mixed in polypropylene syringes with an equal volume (∼1.5 ml) of contrast media, i.e. Accupaque™ 300 (Nycomed Inc.), Imeron® 300 (Bracco S.p.A), Ultravist® 300 (Bayer Pharma AG), Visipaque™ 320 (GE Healthcare) and agitated in a controlled manner to get a homogenous suspension. Syringes with loaded beads in contrast media were stored protected from light under refrigeration (2-8℃). Compatibility was determined by measuring epirubicin concentrations in the suspensions in triplicate on day 0, 1, and 7. A reversed phase high-performance liquid chromatography assay with ultraviolet detection was utilized to analyze the concentration and purity of epirubicin. Mixing of epirubicin-loaded beads with different non-ionic contrast media released 0.1-0.5% of epirubicin over a period of 24 h, irrespectively, of the DC bead™ size or type of contrast media. No further elution or degradation was observed after seven days when the admixtures were stored protected from light under refrigeration. Compatibility of epirubicin-loaded DC bead™ with an equal volume of different contrast media in polypropylene syringes is given over a period of seven days. Due to a maximum elution of 0.1-0.5% of epirubicin from loaded DC bead™, admixtures with contrast media can be prepared in advance in centralized cytotoxic preparation units. Microbiological aspects have to be considered when determining the expiration date of the product. © The Author(s) 2015.
[Quantitative evaluation of Gd-EOB-DTPA uptake in phantom study for liver MRI].
Hayashi, Norio; Miyati, Tosiaki; Koda, Wataru; Suzuki, Masayuki; Sanada, Shigeru; Ohno, Naoki; Hamaguchi, Takashi; Matsuura, Yukihiro; Kawahara, Kazuhiro; Yamamoto, Tomoyuki; Matsui, Osamu
2010-05-20
Gd-EOB-DTPA is a new liver specific MRI contrast media. In the hepatobiliary phase, contrast media is trapped in normal liver tissue, a normal liver shows high intensity, tumor/liver contrast becomes high, and diagnostic ability improves. In order to indicate the degree of uptake of the contrast media, the enhancement ratio (ER) is calculated. The ER is obtained by calculating (signal intensity (SI) after injection-SI before injection) / SI before injection. However, because there is no linearity between contrast media concentration and SI, ER is not correctly estimated by this method. We discuss a method of measuring ER based on SI and T(1) values using the phantom. We used a column phantom, with an internal diameter of 3 cm, that was filled with Gd-EOB-DTPA diluted solution. Moreover, measurement of the T(1) value by the IR method was also performed. The ER measuring method of this technique consists of the following three components: 1) Measurement of ER based on differences in 1/T(1) values using the variable flip angle (FA) method, 2) Measurement of differences in SI, and 3) Measurement of differences in 1/T(1) values using the IR method. ER values calculated by these three methods were compared. In measurement made using the variable FA method and the IR method, linearity was found between contrast media concentration and ER. On the other hand, linearity was not found between contrast media concentration and SI. For calculation of ER using Gd-EOB-DTPA, a more correct ER is obtained by measuring the T(1) value using the variable FA method.
Optimization of propagation-based x-ray phase-contrast tomography for breast cancer imaging
NASA Astrophysics Data System (ADS)
Baran, P.; Pacile, S.; Nesterets, Y. I.; Mayo, S. C.; Dullin, C.; Dreossi, D.; Arfelli, F.; Thompson, D.; Lockie, D.; McCormack, M.; Taba, S. T.; Brun, F.; Pinamonti, M.; Nickson, C.; Hall, C.; Dimmock, M.; Zanconati, F.; Cholewa, M.; Quiney, H.; Brennan, P. C.; Tromba, G.; Gureyev, T. E.
2017-03-01
The aim of this study was to optimise the experimental protocol and data analysis for in-vivo breast cancer x-ray imaging. Results are presented of the experiment at the SYRMEP beamline of Elettra Synchrotron using the propagation-based phase-contrast mammographic tomography method, which incorporates not only absorption, but also x-ray phase information. In this study the images of breast tissue samples, of a size corresponding to a full human breast, with radiologically acceptable x-ray doses were obtained, and the degree of improvement of the image quality (from the diagnostic point of view) achievable using propagation-based phase-contrast image acquisition protocols with proper incorporation of x-ray phase retrieval into the reconstruction pipeline was investigated. Parameters such as the x-ray energy, sample-to-detector distance and data processing methods were tested, evaluated and optimized with respect to the estimated diagnostic value using a mastectomy sample with a malignant lesion. The results of quantitative evaluation of images were obtained by means of radiological assessment carried out by 13 experienced specialists. A comparative analysis was performed between the x-ray and the histological images of the specimen. The results of the analysis indicate that, within the investigated range of parameters, both the objective image quality characteristics and the subjective radiological scores of propagation-based phase-contrast images of breast tissues monotonically increase with the strength of phase contrast which in turn is directly proportional to the product of the radiation wavelength and the sample-to-detector distance. The outcomes of this study serve to define the practical imaging conditions and the CT reconstruction procedures appropriate for low-dose phase-contrast mammographic imaging of live patients at specially designed synchrotron beamlines.
The Social Media DNA of Mayo Clinic-and Health Care.
Kotsenas, Amy L; Aase, Lee; Arce, Makala; Timimi, Farris K; Dacy, Matthew; Young, Colleen; Wald, John T
2018-01-01
Hippocrates' admonition and the medical community's aversion to risk have caused many physicians and institutions to resist participation in modern social media sites such as Facebook (Facebook, Inc, Menlo Park, California, USA), Twitter (Twitter Inc, San Francisco, California, USA), and YouTube (San Mateo, California, USA). However, because Mayo Clinic's founders were champions of analog social networking, it was among the earliest hospitals worldwide to create official accounts on these digital platforms. A proper understanding of the traditional mechanisms of knowledge diffusion in medicine and of the nature of social media sites should help professionals see and embrace the opportunities for positive engagement in social media. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Becker, Joshua; Babb, James; Serrano, Manuel
2013-04-01
The purpose of this study was to use measured glomerular filtration rate (GFR), the reference standard of renal function, to assess the deleterious effect of iodinated contrast media on renal function. Such an effect has been traditionally defined as a greater than 0.5-mg/dL increase in serum creatinine concentration or a 25% or greater increase 24-72 hours after the injection of iodinated contrast medium. This pilot investigation was focused on the consequences of clinically indicated IV injection of iodinated contrast media; intraarterial injection was excluded. One hundred thirteen patients with normal serum creatinine concentrations were enrolled in an approved protocol. At random, as chosen by one of the investigators, patients underwent imaging with one of three monomeric agents (iopamidol 300, iopromide 300, iohexol 300) and one dimeric agent (iodixanol 320). Measured GFR was determined immediately before CT and approximately 3 and 72 hours after the contrast injection for the CT examination. Iodinated contrast medium, a glomerular filtrate with no tubular excretion or reabsorption, was the GFR marker. Measured GFR was determined by x-ray fluorescence analysis with nonisotopic iodinated contrast media. Monomeric and dimeric contrast agents in diagnostic CT volumes (based on bodyweight and imaging protocol) did not induce a significant change in measured GFR (95% confidence by Wilcoxon test), suggesting that use of the evaluated contrast media will not lead to more than a 12% variation. The three monomeric agents studied and the one dimeric agent were equivalent in terms of lack of a significant effect on measured GFR when administered to patients with a normal GFR.
Avoidable errors in dealing with anaphylactoid reactions to iodinated contrast media.
Segal, Arthur J; Bush, William H
2011-03-01
Contrast reactions are much less common today than in the past. This is principally because of the current and predominant use of low and iso-osmolar contrast media compared with the prior use of high osmolality contrast media. As a result of the significantly diminished frequency, there are now fewer opportunities for physicians to recognize and appropriately treat such adverse reactions. In review of the literature combined with our own clinical and legal experience, 12 potential errors were identified and these are reviewed in detail so that they can be avoided by the physician-in-charge. Basic treatment considerations are presented along with a plan to systematize an approach to contrast reactions, simplify treatment options and plans, and schedule periodic drills.
Spindler, Nick; Kaatz, Florian; Feja, Christine; Etz, Christian; Mohr, Friedrich-Wilhelm; Bechmann, Ingo; Josten, Christoph; Langer, Stefan; Loeffler, Sabine
2017-01-01
Introduction: Deep sternal wound infections (DSWI) are a rare but devastating complication after median sternotomy. Minor perfusion in bone and soft tissue, especially after recruiting the internal mammary artery for bypass supports the development of wound infection and nonunion of the sternal bone. The aim of the study was the macroscopic and radiological presentation of the vascular system supplying the sternum, in particular the compensating blood supply routes in the event that the internal mammary artery is no longer available after use as a bypass vessel. Method: This anatomic study was carried out on the anterior chest wall of 7 specimens. The thorax plates of 7 specimens were analyzed macroscopically after microsurgical preparation. Different anatomic preparations were produced using different contrast or form-giving substances. Radiological analysis and three-dimensional reconstructions were performed to show alternative, collateral sternal vessel perfusion under estimation of the loss of the internal thoracic artery due to a bypass. Results: The length of the ITA (internal thoracic artery), measured from the beginning of the first rib to the division into the superior epigastric artery and musculophrenic artery, was an average of 16.3 cm. On average, 18.5 branches were delivered from each artery, 10 medially to the sternum supply, and 8 to the intercostal muscle. Conclusion: Our analysis gives an overview of the macroanatomic vessel system supplying the sternal bone, describing especially a common trunk deriving from the ITA and supplying multiple branches and playing an important role in building a collateral circulation of the sternum. For better evaluation, in vivo CT analysis with contrast media should be performed in patients prior to the operation and directly after the use of the double ITA to demonstrate the change in perfusion of the sternum. In the future, preconditioning of the sternum by coiling the deriving branches could become an option, although patient selection has to be improved and further analysis of the topic performed.
Personal Branding: A Primer for Radiology Trainees and Radiologists.
Kalia, Vivek; Patel, Amy K; Moriarity, Andrew K; Canon, Cheri L
2017-07-01
A radiologist's personal brand is a composite of many parts in one's professional life. In an age where work quality and digital footprints are tracked and measured more than ever before, it behooves radiologists to develop and curate their own individual brands in effective ways. Personal branding consists of the decisions we make, both consciously and unconsciously, which affect our reputation and the likelihood of seeking our services in the future for both patients and referring providers. As hospital systems are increasingly adjusting their systems to cater to better patient experiences, it is imperative that radiologists similarly adjust our practice patterns to accommodate the needs of the new paradigm of value-based care. It is no longer sufficient to only practice excellent clinical radiology; one's service experience to clinical providers, report quality, and digital presence must all be robust and compelling. Defining your brand and promoting your vision and quality standards have become as important to radiologists' future as keeping up with advancements in radiologic technology. One must select the proper platforms and types of interactions in which to engage from available social media options. Developing a consistent brand and presence in the work setting, on social media accounts, and in professional organizations at the local, national, and international levels is the ultimate goal. At present, very little, if any, formal training is provided on personal branding skills such as these in current residency curricula, and it is critical for radiologists to fill their gaps in knowledge through additional means. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
The sensitivity of radiography of the postoperative stomach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ott, D.J.; Munitz, H.A.; Gelfand, D.W.
1982-09-01
The results of radiology and endoscopy were compared in 140 patients who had undergone gastric surgery for ulcer disease. Of 74 patients who were examined with single-contrast radiography, 37 had abnormalities that were demonstrated endoscopically. The radiographic sensitivities in these patients were: gastritis 2/22 (9%); ulcer 3/5 (60%); obstruction 8/8 (100%); and miscellaneous abnormalities 2/2 (100%). The predictive accuracy of a diagnois of ulcer was 38%. Of the 66 patients who were examined with double-contrast radiography, 33 abnormalities were found with endoscopy. The radiographic sensitivities were: gastritis 3/13 (23%); ulcer 7/10 (70%); obstruction 4/4 (100%); and miscellaneous abnormalities 6/6 (100%).more » The predictive accuracy of a diagnosis of ulcer was 44%. Radiology appears to be unreliable in diagnosing gastritis and recurrent ulceration in the post-operation stomach. The double-contrast technique does not offer significant improvement over the single-contrast method in evaluating these postoperative problems.« less
NASA Astrophysics Data System (ADS)
Tu, Shu-Ju; Yang, Pei-Ying; Hong, Ji-Hong; Lo, Ching-Jung
2013-07-01
In CT planning for radiation therapy, patients may be asked to have a medical procedure of contrast agent (CA) administration as required by their physicians. CA media improve quality of CT images and assist radiation oncologists in delineation of the target or organs with accuracy. However, dosimetric discrepancy may occur between scenarios in which CA media are present in CT planning and absent in treatment delivery. In recent preclinical experiments of small animals, gold nanoparticles (AuNPs) have been identified as an excellent contrast material of x-ray imaging. In this work, we quantitatively evaluate the effect of AuNPs to be used as a potential material of contrast enhancement in radiotherapy planning with an analytical phantom and clinical case. Conray 60, an iodine-based product for contrast enhancement in clinical uses, is included as a comparison. Other additional variables such as different concentrations of CA media, radiation delivery techniques and dose calculation algorithms are included. We consider 1-field AP, 4-field box, 7-field intensity modulated radiation therapy (IMRT) and a recent technique of volumetric modulated arc therapy (VMAT). CA media of AuNPs (Conray 60) with concentrations of 10%, 20%, 30%, 40% and 50% containing 28.2, 56.4, 84.6, 112.8 and 141.0 mg of gold (iodine) per mL were prepared prior to CT scanning. A virtual phantom with a target where nanoparticle media are loaded and clinical case of gastric lymphoma in which the Conray 60 media were given to the patient prior to the CT planning are included for the study. Compared to Conray 60 media with concentration of 10%/50%, Hounsfield units for AuNP media of 10%/50% are 322/1608 higher due to the fact that atomic number of Au (Z=79) is larger than I (Z=53). In consequence, dosimetric discrepancy of AuNPs is magnified between presence and absence of contrast media. It was found in the phantom study that percent dose differences between presence and absence of CA media may be reduced by delivery techniques of 7-field IMRT or VMAT. To manage less than 3% of percent dose difference, it was suggested an upper limit of 15% (or 42.3 mg Au/mL) of AuNP media in the phantom study; 8% (or 22.5 mg Au/mL) in the specific clinical case.
Contrast media use in the operating room.
Bickham, Peggy; Golembiewski, Julie
2010-04-01
Iodinated contrast media is frequently used in the OR, but often is not well understood by health care providers who are administering it. Although used for diagnosis rather than treatment, contrast media is classified as a drug by the FDA, and has indications, contraindications, adverse effects, drug interactions, disease interactions, and laboratory interference issues related to its use. Iodinated contrast media is classified according to osmolarity and ionicity, and these characteristics contribute to potential for adverse effects and choice of agent. Financial and safety concerns are factors to be considered when selecting an appropriate agent. Adverse effects can range from mild and self-limited to severe and life threatening; potentially the most serious of these are anaphylactoid reactions and contrast-induced acute renal failure. Knowledge of risk factors and preventive strategies is vital, as are issues related to substitution of gadolinium-based contrast, an off-label use. It is important for the perianesthesia nurse to become familiar with these commonly used imaging medications. Copyright 2010 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.
Kuefner, M A; Feurle, J; Petersen, J; Uder, M; Schwelberger, H G
2014-01-01
Iodinated contrast media can cause pseudoallergic reactions associated with histamine release in significant numbers of patients. To clarify whether these adverse reactions may be aggravated by a compromised histamine catabolism we asked if radiographic contrast agents in vitro inhibit the histamine inactivating enzymes diamine oxidase (DAO) and histamine N-methyltransferase (HMT). Nine iodinated contrast agents were tested in vitro. Following pre-incubation of purified porcine kidney DAO and recombinant human HMT with 0.1-10mM of the respective contrast medium (H2O and specific inhibitors of DAO and HMT as controls) enzyme activities were determined by using radiometric micro assays. None of the contrast media irrespective of their structure showed significant inhibition of the activities of DAO and HMT. Pre-incubation of the enzymes with specific inhibitors led to complete inhibition of the respective enzymatic activity. The iodinated contrast media tested in vitro did not exhibit inhibition of histamine converting enzymes at physiologically relevant concentrations. However due to the in vitro character of this study these results do not directly reflect the in vivo situation. Copyright © 2012 SEICAP. Published by Elsevier Espana. All rights reserved.
Life-Threatening Thrombocytopenia Following Intravenous Contrast Media Infusion.
Park, Mihwa; Kim, Minjeong; Park, Jisun; Cho, Jinhyun
2018-01-01
Radiocontrast media-induced acute severe thrombocytopenia is a very rare complication and potentially life-threatening. Here, we report the case of a 63-year-old male patient with severe acute thrombocytopenia following first exposure to intravenous non-ionic contrast media without immediate allergic reactions. His platelet count dropped from 107000/μL to 2000/μL after six hours of radiocontrast infusion. After administration of corticosteroid and transfusion of platelet concentrates, the platelet count returned gradually to normal within 5 days. To the best of our knowledge, non-ionic contrast media-induced isolated acute severe thrombocytopenia following no signs or symptoms of immediate allergic reaction has never been described. © Copyright: Yonsei University College of Medicine 2018.
Durfee, Sara M; Jain, Sidney; Shaffer, Kitt
2003-02-01
The purpose of this study was to define the current use of information technology in radiology tutorials for medical students. The authors conducted a Web-based survey of directors of medical school courses in radiology. The survey dealt with the details of the courses and the use of computers and the Web during the courses. There were 48 responses. Most radiology courses were elective (73%) and were offered monthly. Most institutions (79%) had picture archiving and communication systems (PACS) available or were completely filmless. The teaching case presentations, however, often included film images displayed on a view box or by an overhead projector. Computers dedicated to student use were uncommon (28%). The Web was used infrequently as a teaching resource, and a Web site was not available in most courses. Computer technical support was variable and usually provided by the course director. Course directors at institutions with PACS were more likely to use digital technology for case presentations and more likely to use the Web for teaching purposes. Despite the widespread use of digital technology and PACS in the field of radiology, digital technology is underused in radiology courses. However, departments with PACS tend to use digital technology more frequently in education than do departments without PACS.
Radiologic Professionalism in Modern Health Care.
Hryhorczuk, Anastasia L; Hanneman, Kate; Eisenberg, Ronald L; Meyer, Elaine C; Brown, Stephen D
2015-10-01
Modern radiology is at the forefront of technological progress in medicine, a position that often places unique challenges on its professional character. This article uses "Medical Professionalism in the New Millennium: A Physician Charter," a document published in 2002 and endorsed by several major radiology organizations, as a lens for exploring professional challenges in modern radiology. The three main tenets of the Charter emphasize patient welfare, patient autonomy, and the reduction of disparities in health care distribution. This article reviews the ways in which modern technology and financial structures potentially create stressors on professionalism in radiology, while highlighting the opportunities they provide for radiologists seeking to fulfill the professional goals articulated in the Charter. Picture archiving and communication systems (PACS) and voice recognition systems have transformed the speed of radiology and enhanced the ability of radiologists to improve patient care but also have brought new tensions to the workplace. Although teleradiology may improve global access to radiologists, it may also promote the commoditization of radiology, which diminishes the professional stature of radiologists. Social media and patient portals provide radiologists with new forums for interacting with the public and patients, potentially promoting patient welfare. However, patient privacy and autonomy are important considerations. Finally, modern financial structures provide radiologists with both entrepreneurial opportunities as well as the temptation for unprofessional conduct. Each of these advances carries the potential for professional growth while testing the professional stature of radiology. By considering the risks and benefits of emerging technologies in the modern radiology world, radiologists can chart an ethical and professional future path. © RSNA, 2015.
Meaningful Peer Review in Radiology: A Review of Current Practices and Potential Future Directions.
Moriarity, Andrew K; Hawkins, C Matthew; Geis, J Raymond; Dreyer, Keith J; Kamer, Aaron P; Khandheria, Paras; Morey, Jose; Whitfill, James; Wiggins, Richard H; Itri, Jason N
2016-12-01
The current practice of peer review within radiology is well developed and widely implemented compared with other medical specialties. However, there are many factors that limit current peer review practices from reducing diagnostic errors and improving patient care. The development of "meaningful peer review" requires a transition away from compliance toward quality improvement, whereby the information and insights gained facilitate education and drive systematic improvements that reduce the frequency and impact of diagnostic error. The next generation of peer review requires significant improvements in IT functionality and integration, enabling features such as anonymization, adjudication by multiple specialists, categorization and analysis of errors, tracking, feedback, and easy export into teaching files and other media that require strong partnerships with vendors. In this article, the authors assess various peer review practices, with focused discussion on current limitations and future needs for meaningful peer review in radiology. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Picture archiving and communication system--Part one: Filmless radiology and distance radiology.
De Backer, A I; Mortelé, K J; De Keulenaer, B L
2004-01-01
Picture archiving and communication system (PACS) is a collection of technologies used to carry out digital medical imaging. PACS is used to digitally acquire medical images from the various modalities, such as computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, and digital projection radiography. The image data and pertinent information are transmitted to other and possibly remote locations over networks, where they may be displayed on computer workstations for soft copy viewing in multiple locations, thus permitting simultaneous consultations and almost instant reporting from radiologists at a distance. Data are secured and archived on digital media such as optical disks or tape, and may be automatically retrieved as necessary. Close integration with the hospital information system (HIS)--radiology information system (RIS) is critical for system functionality. Medical image management systems are maturing, providing access outside of the radiology department to images throughout the hospital via the Ethernet, at different hospitals, or from a home workstation if teleradiology has been implemented.
Hand-held digital books in radiology: convenient access to information.
D'Alessandro, M P; Galvin, J R; Santer, D M; Erkonen, W E
1995-02-01
Radiologists need constant, convenient access to current information throughout the course of their daily work. Today most learning in radiology is obtained from the printed word in books, journals, and teaching files, supplemented by the spoken word in lectures and conferences. Although learning from printed material and lectures has been proved efficacious over time, these media share the disadvantage of not being conveniently available for reference during the course of daily work at the alternator or in the examination room when accurate and up-to-date information is needed the most. As a result, many important questions about patient care go unanswered. We have developed a technique--hand-held digital books--to lower this barrier to searching and retrieval. When radiologists have a digital library that can be carried with them, they will be able to incorporate current radiology information into their daily decision making. We describe a technique for creating hand-held digital books and their future use in radiology.
A national UK survey of radiology trainees special interest choices: what and why?
Parvizi, Nassim; Bhuva, Shaheel
2017-11-01
A national survey was designed to better understand factors influencing special interest choices, future aspirations of UK radiology trainees and perceptions of breast radiology. A SurveyMonkey questionnaire was developed and distributed to all radiology trainees in the UK through the British Institute of Radiology, RCR Junior Radiologists Forum and by directly contacting UK training schemes as well as by social media between December 2015 and January 2016. From 21 training schemes across the UK, 232 responses were received. Over half entered radiology after foundation training and 62% were ST1-3; one-fifth of trainees intended to leave the NHS. The most popular special interests were musculoskeletal (18%), abdominal imaging (16%) and neuroradiology (13%). Gynaecological and oncological imaging proved to be the least popular. Strong personal interest, a successful rotation during training, a mix of imaging modalities, direct impact on patient care and job prospects were the most popular factors influencing career choice. Research and potential for private income were the least influential factors. Respondents detailed their perceptions of breast radiology, selecting an awareness of career prospects (41%) and a better trainee experience (36%) as factors that would increase their interest in pursuing it as a career. Understanding the factors that influence special interest choice is essential to addressing the alarming staffing shortfalls that will befall certain radiology special interests. Addressing trainee's preconceptions and improving the trainee experience are key to attracting trainees to breast radiology. Advances in knowledge: This is the first survey of its kind in the UK literature designed to evaluate special interest career choices and the factors that influence those among radiology trainees.
Kurihara, Osamu; Takano, Masamichi; Uchiyama, Saori; Fukuizumi, Isamu; Shimura, Tetsuro; Matsushita, Masato; Komiyama, Hidenori; Inami, Toru; Murakami, Daisuke; Munakata, Ryo; Ohba, Takayoshi; Hata, Noritake; Seino, Yoshihiko; Shimizu, Wataru
2015-12-01
Contrast-induced nephropathy (CIN) is considered to result from intrarenal vasoconstriction, and occurs more frequently in impaired than in normal kidneys. It was hypothesized that iodinated contrast media would markedly change renal blood flow and vascular resistance in functionally impaired kidneys. Thirty-six patients were enrolled (32 men; mean age, 75.3 ± 7.6 years) undergoing diagnostic coronary angiography and were divided into two groups based on the presence of chronic kidney disease (CKD), defined as an estimated glomerular filtration rate (eGFR) of < 60 mL/min per 1.73 m(2) (CKD and non-CKD groups, n = 18 in both). Average peak velocity (APV) and renal artery resistance index (RI) were measured by Doppler flow wire before and after administration of the iodinated contrast media. The APV and the RI were positively and inversely correlated with the eGFR at baseline, respectively (APV, R = 0.545, P = 0.001; RI, R = -0.627, P < 0.001). Mean RI was significantly higher (P = 0.015) and APV was significantly lower (P = 0.026) in the CKD than in the non-CKD group. Both APV (P < 0.001) and RI (P = 0.002) were significantly changed following contrast media administration in the non-CKD group, but not in the CKD group (APV, P = 0.258; RI, P = 0.707). Although renal arterial resistance was higher in patients with CKD, it was not affected by contrast media administration, suggesting that patients with CKD could have an attenuated response to contrast media. © 2015 The Authors. Clinical and Experimental Pharmacology and Physiology Published by Wiley Publishing Asia Pty Ltd.
Deek, Hiba; Newton, Phillip; Sheerin, Noella; Noureddine, Samar; Davidson, Patricia M
2014-11-01
Contrast media induced nephropathy (CIN) is a sudden compromise of renal function 24-48 h after administering contrast medium during a CT scan or angiography. CIN accounts for 10% of hospital acquired renal failure and is ranked the third cause of acquiring this condition. Identifying patients at risk through proper screening can reduce the occurrence of this condition. This review paper aims to critique current evidence, provide a better understanding of CIN, inform nursing practice and make recommendations for bedside nurses and future research. An integrative review of the literature was made using the key terms: "contrast media", "nephritis", "nephropathy", "contrast media induced nephropathy scores", "acute kidney failure", "acute renal failure" and "acute kidney injury". MeSH key terms used in some databases were: "prevention and control", "acute kidney failure" and "treatment". Databases searched included Medline, CINAHL and Academic Search Complete, and references of relevant articles were also assessed. The search included all articles between the years 2000 and 2013. Sixty-seven articles were obtained as a result of the search, including RCTs, systematic reviews, and retrospective studies. Contrast media induced nephropathy is an iatrogenic complication occurring secondary to diagnostic or therapeutic procedures. At times it is unavoidable but a systematic method of risk assessment should be adopted to identify high risk patients for tailored and targeted approaches to management interventions. As the use of contrast media is increasing for diagnostic purposes, it is important that nurses be aware of the risk factors for CIN, identify and monitor high risk patients to prevent deterioration in renal function when possible. Copyright © 2014 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
Trends in radiology and experimental research.
Sardanelli, Francesco
2017-01-01
European Radiology Experimental , the new journal launched by the European Society of Radiology, is placed in the context of three general and seven radiology-specific trends. After describing the impact of population aging, personalized/precision medicine, and information technology development, the article considers the following trends: the tension between subspecialties and the unity of the discipline; attention to patient safety; the challenge of reproducibility for quantitative imaging; standardized and structured reporting; search for higher levels of evidence in radiology (from diagnostic performance to patient outcome); the increasing relevance of interventional radiology; and continuous technological evolution. The new journal will publish not only studies on phantoms, cells, or animal models but also those describing development steps of imaging biomarkers or those exploring secondary end-points of large clinical trials. Moreover, consideration will be given to studies regarding: computer modelling and computer aided detection and diagnosis; contrast materials, tracers, and theranostics; advanced image analysis; optical, molecular, hybrid and fusion imaging; radiomics and radiogenomics; three-dimensional printing, information technology, image reconstruction and post-processing, big data analysis, teleradiology, clinical decision support systems; radiobiology; radioprotection; and physics in radiology. The journal aims to establish a forum for basic science, computer and information technology, radiology, and other medical subspecialties.
Nursing role model for computed tomography contrast injection decreases extravasation rates.
Kadom, Nadja; Hashim, Hayder D; Olsen, Cara; Cefaratti, Marjean; Bulas, Dorothy; Shalaby-Rana, Eglal
2012-04-01
Extravasation of intravenous contrast administered for computed tomography remains of concern in pediatric patients. It is of great interest to any pediatric radiology department to decrease extravasation events in an effort to reduce even small adverse outcomes and improve the overall patient experience in the radiology department. Here, a total of 17 extravasation events, as reported and documented in departmental quality assurance at our institution over 4 years, were retrospectively reviewed for factors contributing to the number of adverse extravasation events. We found that pediatric nursing plays a central role in both achieving and maintaining a low extravasation rate at our institution. Copyright © 2012 Elsevier Inc. All rights reserved.
Ghalandarlaki, N; Mohammadi, T D; Agha Babaei, R; Tabasi, M A; Keyhanvar, P; Mehravi, B; Yaghmaei, P; Cohan, R A; Ardestani, M S
2014-02-01
By advancing of molecular imaging techniques, magnetic resonance imaging (MRI) is becoming an increasingly important tool in early diagnosis. Researchers have found new ways to increase contrast of MRI images.Therefore some types of drug known as contrast media are produced. Contrast media improve the visibility of internal body structures in MRI images. Gadodiamide (Omniscan®) is one of these contrast media which is produced commercially and used clinically. In this study Gadodiamide was first synthesized and then qualitative and quantitative methods were carried out to ensure the proper synthesis of this drug then to increase the efficiency of this contrast medium use dendrimer that is one kind of nano particle. This dendrimer has a polyethylene glycol (PEG) core and citric acid branches. After dendrimer attached to Gadodiamide to ensure the proper efficient connection between them the stability studies were carried out and cytotoxicity of the drug was evaluated. Finally, after ensuring the non-toxicity of the drug, in vivo studies (injected into mice) MR imaging was performed to examine the impact of synthesis drug on the resolution of image.The result obtained from this study demonstrated that the attachment of Gadodiamide to dendrimer reduces its cytotoxicity and also improved resolution of image. Also the new contrast media (Gd3+-DTPA- bis [N-methylamine] - Dendrimer) - unlike Omniscan® - is biodegradable and able to enter the HEPG2 cell line. The results confirm the hypothesis that using dendrimer to synthesize this new nano contrast medium increases its effectiveness. © Georg Thieme Verlag KG Stuttgart · New York.
Sessa, Maurizio; Rossi, Claudia; Mascolo, Annamaria; Scavone, Cristina; di Mauro, Gabriella; Grassi, Roberto; Sportiello, Liberata; Cappabianca, Salvatore; Rafaniello, Concetta
2017-01-01
The use of contrast media in Italy has exponentially increased in the past 3 decades. However, it is unknown whether there has been an increase in clinical research evaluating the risks associated with contrast media usage, especially regarding contrast-induced nephropathy. To fill this gap in knowledge, we performed a systematic review. Meta-analyses, observational studies, and clinical trials assessing contrast media-induced nephropathy as the safety outcome, in which at least one author was affiliated with an Italian university/health care structure, were eligble. Ovid MEDLINE, Ovid Embase, Cochrane Methodology Register, and Web of Science were screened. Men and women exposed to contrast media. In total, 60 original articles were retrieved with an incremental trend between 1990 and 2017. Cohort studies were the most common study design represented. In total, 45 of 60 (75.0%) studies were monocenter studies and 41 of 60 (68.3%) received no funding. In all, 91.7% of studies disclosed no conflicts of interest and 81.7% had no external collaboration. Most of the studies provided a level of evidence of III-2 (32/60; 53.3%) and II (23/60; 38.3%). In total, 50 of 60 studies (83.3%) were published in a scientific journal ranked in the first quartile of their subject area. There was an increased number of studies evaluating contrast-induced nephropathy in Italy during the last three decades. These studies covered procedures to prevent contrast-induced nephropathy or aimed to identify risk factors, biomarkers, and scores, and their related prognosis.
Yoshikawa, Hiroto; Roback, Donald M; Larue, Susan M; Nolan, Michael W
2015-01-01
Potential benefits of planning radiation therapy on a contrast-enhanced computed tomography scan (ceCT) should be weighed against the possibility that this practice may be associated with an inadvertent risk of overdosing nearby normal tissues. This study investigated the influence of ceCT on intensity-modulated stereotactic body radiotherapy (IM-SBRT) planning. Dogs with head and neck, pelvic, or appendicular tumors were included in this retrospective cross-sectional study. All IM-SBRT plans were constructed on a pre- or ceCT. Contours for tumor and organs at risk (OAR) were manually constructed and copied onto both CT's; IM-SBRT plans were calculated on each CT in a manner that resulted in equal radiation fluence. The maximum and mean doses for OAR, and minimum, maximum, and mean doses for targets were compared. Data were collected from 40 dogs per anatomic site (head and neck, pelvis, and limbs). The average dose difference between minimum, maximum, and mean doses as calculated on pre- and ceCT plans for the gross tumor volume was less than 1% for all anatomic sites. Similarly, the differences between mean and maximum doses for OAR were less than 1%. The difference in dose distribution between plans made on CTs with and without contrast enhancement was tolerable at all treatment sites. Therefore, although caution would be recommended when planning IM-SBRT for tumors near "reservoirs" for contrast media (such as the heart and urinary bladder), findings supported the use of ceCT with this dose calculation algorithm for both target delineation and IM-SBRT treatment planning. © 2015 American College of Veterinary Radiology.
Wang, Jian; Xiang, Bo; Lin, Hung Yu; Liu, Hongyu; Freed, Darren; Arora, Rakesh C.; Tian, Ganghong
2015-01-01
Objectives Because the distribution volume and mechanism of extracellular and intravascular MR contrast media differ considerably, the enhancement pattern of chronic myocardial infarction with extracellular or intravascular media might also be different. This study aims to investigate the differences in MR enhancement patterns of chronic myocardial infarction between extracellular and intravascular contrast media. Materials and Methods Twenty pigs with myocardial infarction underwent cine MRI, first pass perfusion MRI and delayed enhancement MRI with extracellular or intravascular media at four weeks after coronary occlusion. Myocardial blood flow (MBF) was determined with microsphere measurement. The infarction histopathological changes were evaluated by hematoxylin and eosin staining and Masson's trichrome method. Results Cine MRI revealed the reduced wall thickening in chronic infarction compared with normal myocardium. Moreover, significant wall thinning in chronic infarction was observed in cine MRI. Peak first-pass signal intensity didn’t significantly differ between chronic infarction and normal myocardium no matter what kinds of contrast media. At the following delayed enhancement phase, extracellular media-enhanced signal intensity was significantly higher in chronic infarction than in normal myocardium. Conversely, intravascular media-enhanced signal intensity was almost equivalent among chronic infarction and normal myocardium. At four weeks after infarction, MBF in chronic infarction approached to that in normal myocardium. Large thick-walled vessels were detected at peri-infarction zones. The cardiomyocytes were replaced by scar tissue consisting of dilated blood vessels and discrete fibers of collagen. Conclusions Chronic infarction was characterized by the significantly reduced wall thickening and the definite wall thinning. First-pass myocardial perfusion defect was not detected in chronic infarction with two media due to the significantly recovered MBF and well-developed collateral vessels. Infarction remodeling enlarged the extracellular compartment, which was available for extracellular media but not accessible to intravascular media. Extracellular media identified chronic infarction as the hyper-enhancement; nonetheless, intravascular media didn’t provide delayed enhancement. PMID:25816056
Prezelj, Iztok; Perko, Tanja; Cantone, Marie C; Gallego, Eduardo; Tomkiv, Yevgeniya; Oughton, Deborah H
2016-06-01
Coordination of public communication has become a key issue in management of complex emergencies, and is a matter of debate between nuclear emergency management professionals. A particular problem is when inconsistent information is sent to the media and public by official sources from different levels, which has led to calls for a more coordinated approach. The IAEA created guidelines recommending a one-voice communication approach that provides clear, consistent and coordinated information by relevant stakeholders. The reviewed theory on the emergency communication coordination and the empirical results in this paper demonstrate some challenges regarding the feasibility of the above stated goal. This paper explores the communication process in the two-month period of the Fukushima nuclear emergency by using a quantitative comparative content and discourse analysis of 1340 printed media articles on the Fukushima nuclear disaster from two major newspapers in Spain ('El País' and 'El Mundo'), Italy ('Corriere della Sera' and 'La Repubblica'), Norway ('Aftenposten' and 'Dagsavisen'), Slovenia ('Delo' and 'Večer'), Belgium ('Le Soir' and 'De Standaard') and Russia ('Komsomolskaya Pravda' and 'Izvestiya'). The results show that it will be difficult to achieve a truly coordinated approach and one-voice communication in severe nuclear and radiological emergency due to the communication difficulties created by the dispersion of information sources, a broad and dispersed focus of the reported information, partially subjective and conflicting media reporting. The paper suggests ways to improve public communication coordination in nuclear and radiological disasters.
Young, Kenneth J.; Siordia, Lawrence
2012-01-01
Objective The purpose of this study was to track the graduates of the Los Angeles College of Chiropractic (LACC) radiology residency program, review their scholarly productivity, and report those involved in teaching and leadership positions. Methods Former LACC residents’ career information was identified through publicly available electronic documents including Web sites and social media. PubMed and the Index to Chiropractic Literature databases were searched for chiropractic graduate job surveys, and proportional comparisons were made between the career paths of LACC radiology residency graduates and those of non–residency-trained chiropractors. Results Of 47 former LACC residents, 28 (60%) have or previously had careers in tertiary (chiropractic) education; and 12 (26%) have attained a department chair position or higher at tertiary teaching institutions. Twenty-two (47%) have or previously had private radiology practices, whereas 11 (23%) have or previously had clinical chiropractic practices. Often, residency graduates hold or have held 2 of these positions at once; and one, all 3. Chapters or books were authored by 13 (28%). Conclusion Radiology residency LACC graduates are professionally active, particularly in education, and demonstrate scholarly productivity. PMID:23966885
Radiology medical student education: an outcome-based survey of PGY-1 residents.
Saha, Arnold; Roland, R Andrew; Hartman, Matthew S; Daffner, Richard H
2013-03-01
Postgraduate year (PGY)-1 residents are frequently required to order imaging studies and make preliminary interpretations on them. This study determines whether PGY-1 residents feel their radiology education in medical school sufficiently trained them for the clinical responsibilities of internship. This multicenter, institutional review board-approved survey asked PGY-1 trainees three categories of questions: 1) extent of medical school training for ordering and interpreting imaging studies, 2) confidence levels in ordering appropriate imaging studies and making common/emergent diagnoses, and 3) rating the importance of radiologic interpretation by interns. Respondents also submitted ideas for medical school teaching topics deemed most useful for interns. A total of 175 questionnaires were returned with good representation across specialties. Although 63.7% of interns were frequently asked to independently preview radiology studies, 12.6% received no formal radiology training in medical school. Participants rated chest radiographs as the most important study for interns to competently interpret (93.4% reporting very or extremely important). However, only 60.2% of interns reported high confidence in recognizing common/emergent pulmonary findings, and 56.3% for evaluating line and tube position. With regard to ordering imaging studies, 81.0% had never used or never heard of the American College of Radiology Appropriateness Criteria®. Only 33.1% had high confidence in knowing when to order oral/intravenous contrast. Similar low percentages had high confidence identifying and premedicating contrast allergies (36.4%) and knowing risk factors of nephrogenic systemic fibrosis (13.2%). PGY-1 residents feel that medical school curriculum emphasizing interpretation of chest radiographs and ordering appropriate imaging studies would better prepare students for the responsibilities of internship. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
Application of oral contrast media in coregistered positron emission tomography-CT.
Dizendorf, Elena V; Treyer, Valerie; Von Schulthess, Gustav K; Hany, Thomas F
2002-08-01
Coregistration of positron emission tomography (PET) and CT images results in significantly improved localization of abnormal FDG uptake compared with PET images alone. For delineation of intestinal structures, application of oral contrast media is a standard procedure in CT. The influence of oral contrast agents in PET imaging using CT data for attenuation correction was evaluated in a comparative study on an in-line PET-CT system. Sixty patients referred for PET-CT were evaluated in two groups. One group of 30 patients received oral Gastrografin 45 min before data acquisition. The second group received no contrast medium. PET images were reconstructed, using CT data for attenuation correction. Image analysis was performed by two reviewers in consensus, using a 4-point scale comparing FDG-uptake in the gastrointestinal tract in PET images of both groups. Furthermore, correlation of FDG uptake and localization of contrast media in the intestinal tract in CT images were determined. No significant difference in FDG uptake in PET images in all regions of the gastrointestinal tract except the ascending colon was seen in both groups. No correlation was found in the location of increased FDG uptake and contrast media in the CT images. An oral contrast agent can be used for coregistered PET-CT without the introduction of artifacts in PET.
Basic nonlinear acoustics: an introduction for radiological physicists.
Harpen, Michael D
2006-09-01
Presented is a brief introduction to nonlinear acoustics, a topic of increasing importance in modern diagnostic ultrasound. Specifically treated is shock wave and harmonic production in lossless media. We also present a description of linear attenuation mechanisms in soft tissue and finally nonlinear propagation in soft tissue.
Piccotti, K; Guida, D; Carbonetti, F; Stefanetti, L; Macioce, A; Cremona, A; David, V
Comparison of diagnostic quality in hysterosalpingography between low and high-osmolality contrast media. We performed a retrospective evaluation of two cohorts of patients who underwent HSG using contrast media with different osmolarity: the first group ,47 patients, underwent hysterosalpingography in the period September 2011-December 2012 using Iopromide 370 mg/ml; the second group, 50 patients, underwent HSG from January 2013 to October 2013 using Iomeprol 400 mg/ml. Three radiologists, in consensus reading,, reviewed the radiographs by assessing the following four parameters: opacification of the uterine cavity, uterine profiles definition, Fallopian tubes visualization, contrast media spillage into peritoneum. A score-scale from 0 to 3 was assigned for each of the mentioned parameter (0 = minimum non-diagnostic exam, 1 = sufficient examination; 2 = good quality examination; maximum 3 = high quality images). We documented a statistically significant higher quality in displaying Fallopian tubes among patients studied through high osmolarity contrast medium (Iopromide 370 mg/ml) than what obtained through lower osmolarity contrast medium (Iomeprol 400 mg/ml). The use of high osmolarity contrast medium enabled better visualization of the tubes and a greater number of diagnoses of chronic aspecific salpigintis due to the increased osmolality and viscosity of Iomeprol 400 mg/ml. There were no significant differences between the two contrast agents in the evaluation of intra-uterine pathology and in the evaluation of the tubal patency.
Vörös, Eszter; Deres, László; Halmosi, Róbert; Várady, Edit; Tóth, Kálmán; Battyáni, István
2017-01-01
Iodinated contrast media (Xenetix®, Ultravist®, Omnipaque®, Visipaque® and Iomeron®) used for computed tomography (CT) may decrease fibrinolysis by recombinant tissue plasminogen activator (rt-PA). We hypothesized that receiving iodinated contrast media before rt-PA may impair thrombolysis as measured by a new model system. Whole blood from Wistar Kyoto rats (n = 10) was obtained and allowed to form blood clots. Thrombolysis was performed by placing individually the prepared clots into 15 mL tubes and adding 5 mL saline buffer, 100μg rt-PA and a different contrast media; adjusting the quantity of iodine to either 30 mg or 60 mg. The thrombolytic efficacy was quantified by measuring the optical density (OD415) of the supernatant at different time points, namely at 0, 30, 60, and 90 min. There was a significant decrease in clot lysis efficiency observed in presence of iodine containing contrast media comparing to positive control group. Moreover, when the quantity of iodine was increased from 30 mg to 60 mg; the dissolution rate downturned with additional ∼50%. In conclusion, our study suggests that high dose of iodine potentially could negatively affect the efficiency of the thrombolytic therapy performed by rt-PA.
Dykes, Thomas M; Bhargavan-Chatfield, Mythreyi; Dyer, Raymond B
2015-02-01
Establish 3 performance benchmarks for intravenous contrast extravasation during CT examinations: extravasation frequency, distribution of extravasation volumes, and severity of injury. Evaluate the effectiveness of implementing practice quality improvement (PQI) methodology in improving performance for these 3 benchmarks. The Society of Abdominal Radiology and ACR developed a registry collecting data for contrast extravasation events. The project includes a PQI initiative allowing for process improvement. As of December 2013, a total of 58 radiology practices have participated in this project, and 32 practices have completed the 2-cycle PQI. There were a total of 454,497 contrast-enhanced CT exams and 1,085 extravasation events. The average extravasation rate is 0.24%. The median extravasation rate is 0.21%. Most extravasations (82.9%) were between 10 mL and 99 mL. The majority of injuries, 94.6%, are mild in severity, with 4.7% having moderate and 0.8% having severe injuries. Data from practices that completed the PQI process showed a change in the average extravasation rate from 0.28% in the first 6 months to 0.23% in the second 6 months, and the median extravasation rate dropped from 0.25% to 0.16%, neither statistically significant. The distribution of extravasation volumes and the severity of injury did not change between the first and second measurement periods. National performance benchmarks for contrast extravasation rate, distribution of volumes of extravasate, and distribution of severity of injury are established through this multi-institutional practice registry. The application of PQI failed to have a statistically significant positive impact on any of the 3 benchmarks. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Various clinical application of phase contrast X-ray
NASA Astrophysics Data System (ADS)
Oh, Chilhwan; Park, Sangyong; Ha, Seunghan; Park, Gyuman; Lee, Gunwoo; Lee, Onseok; Je, Jungho
2008-02-01
In biomedical application study using phase contrast X-ray, both sample thickness or density and absorption difference are very important factors in aspects of contrast enhancement. We present experimental evidence that synchrotron hard X-ray are suitable for radiological imaging of biological samples down to the cellular level. We investigated the potential of refractive index radiology using un-monochromatized synchrotron hard X-rays for the imaging of cell and tissue in various diseases. Material had been adopted various medical field, such as apoE knockout mouse in cardiologic field, specimen from renal and prostatic carcinoma patient in urology, basal cell epithelioma in dermatology, brain tissue from autosy sample of pakinson's disease, artificially induced artilrtis tissue from rabbits and extracted tooth from patients of crack tooth syndrome. Formalin and paraffin fixed tissue blocks were cut in 3 mm thickness for the X-ray radiographic imaging. From adjacent areas, 4 μm thickness sections were also prepared for hematoxylin-eosin staining. Radiographic images of dissected tissues were obtained using the hard X-rays from the 7B2 beamline of the Pohang Light Source (PLS). The technique used for the study was the phase contrast images were compared with the optical microscopic images of corresponding histological slides. Radiographic images of various diseased tissues showed clear histological details of organelles in normal tissues. Most of cancerous lesions were well differentiated from adjacent normal tissues and detailed histological features of each tumor were clearly identified. Also normal microstructures were identifiable by the phase contrast imaging. Tissue in cancer or other disease showed clearly different findings from those of surrounding normal tissue. For the first time we successfully demonstrated that synchrotron hard X-rays can be used for radiological imaging of relatively thick tissue samples with great histological details.
Prevention and Management of Adverse Reactions Induced by Iodinated Contrast Media.
Wu, Yi Wei; Leow, Kheng Song; Zhu, Yujin; Tan, Cher Heng
2016-04-01
Iodinated radiocontrast media (IRCM) is widely used in current clinical practice. Although IRCM is generally safe, serious adverse drug reactions (ADRs) may still occur. IRCM-induced ADRs may be subdivided into chemotoxic and hypersensitivity reactions. Several factors have been shown to be associated with an increased risk of ADRs, including previous contrast media reactions, history of asthma and allergic disease, etc. Contrast media with lower osmolality is generally recommended for at-risk patients to prevent ADRs. Current premedication prophylaxis in at-risk patients may reduce the risk of ADRs. However, there is still a lack of consensus on the prophylactic role of premedication. Contrast-induced nephropathy (CIN) is another component of IRCM-related ADRs. Hydration remains the mainstay of CIN prophylaxis in at-risk patients. Despite several preventive measures, ADRs may still occur. Treatment strategies for potential contrast reactions are also summarised in this article. This article summarises the pathophysiology, epidemiology and risk factors of ADRs with emphasis on prevention and treatment strategies. This will allow readers to understand the rationale behind appropriate patient preparation for diagnostic imaging involving IRCM.
Acute Respiratory Distress Syndrome after the Use of Gadolinium Contrast Media.
Park, Jihye; Byun, Il Hwan; Park, Kyung Hee; Lee, Jae-Hyun; Nam, Eun Ji; Park, Jung-Won
2015-07-01
Acute respiratory distress syndrome (ARDS) is a medical emergency that threatens life. To this day, ARDS is very rarely reported by iodine contrast media, and there is no reported case of ARDS induced by gadolinium contrast media. Here, we present a case with ARDS after the use of gadobutrol (Gadovist) as a magnetic resonance imaging (MRI) contrast medium. A 26 years old female without any medical history, including allergic diseases and without current use of drugs, visited the emergency room for abdominal pain. Her abdominopelvic computed tomography with iodine contrast media showed a right ovarian cyst and possible infective colitis. Eighty-three hours later, she underwent pelvis MRI after injection of 7.5 mL (0.1 mL/kg body weight) of gadobutrol (Gadovist) to evaluate the ovarian cyst. She soon presented respiratory difficulty, edema of the lips, nausea, and vomiting, and we could hear wheezing upon auscultation. She was treated with dexamethasone, epinephrine, and norepinephrine. Her chest X-ray showed bilateral central bat-wing consolidative appearance. Managed with mechanical ventilation, she was extubated 3 days later and discharged without complications.
Mascolo, Annamaria; Scavone, Cristina; di Mauro, Gabriella; Grassi, Roberto; Sportiello, Liberata; Cappabianca, Salvatore; Rafaniello, Concetta
2017-01-01
Background and objective The use of contrast media in Italy has exponentially increased in the past 3 decades. However, it is unknown whether there has been an increase in clinical research evaluating the risks associated with contrast media usage, especially regarding contrast-induced nephropathy. To fill this gap in knowledge, we performed a systematic review. Study eligibility criteria Meta-analyses, observational studies, and clinical trials assessing contrast media-induced nephropathy as the safety outcome, in which at least one author was affiliated with an Italian university/health care structure, were eligble. Data sources Ovid MEDLINE, Ovid Embase, Cochrane Methodology Register, and Web of Science were screened. Participants Men and women exposed to contrast media. Results In total, 60 original articles were retrieved with an incremental trend between 1990 and 2017. Cohort studies were the most common study design represented. In total, 45 of 60 (75.0%) studies were monocenter studies and 41 of 60 (68.3%) received no funding. In all, 91.7% of studies disclosed no conflicts of interest and 81.7% had no external collaboration. Most of the studies provided a level of evidence of III-2 (32/60; 53.3%) and II (23/60; 38.3%). In total, 50 of 60 studies (83.3%) were published in a scientific journal ranked in the first quartile of their subject area. Conclusion There was an increased number of studies evaluating contrast-induced nephropathy in Italy during the last three decades. These studies covered procedures to prevent contrast-induced nephropathy or aimed to identify risk factors, biomarkers, and scores, and their related prognosis. PMID:29123405
Liu, Zhimin; Song, Lei; Yu, Tong; Gao, Jun; Zhang, Qifeng; Jiang, Ling; Liu, Yong; Peng, Yun
2016-09-01
The aim of this study was to explore the feasibility of using low dose radiation and low concentration contrast media in enhanced CT examinations in children with congenital heart disease. Ninety patients with congenital heart disease were randomly divided into three groups of 30 patients each who underwent contrast-enhanced cardiac scans on a Discovery CT750 HD scanner. Group A received 270 mg I/mL iodixanol, and group B received 320 mg I/mL iodixanol contrast media and was scanned with prospective ECG triggering mode. Group C received 320 mg I/mL iodixanol and was scanned with conventional retrospective ECG gating mode. The same weight-based contrast injection protocol was used for all three groups. Images were reconstructed using a 30% adaptive statistical iterative reconstruction (ASIR) algorithm and a 50% ASIR in groups A and B and a 30% ASIR in group C. The subjective and objective image quality evaluations, diagnostic accuracies, radiation doses and amounts of contrast media in the three groups were measured and compared. All images in the three groups met the diagnostic requirements, with the same diagnostic accuracy and image quality scores greater than 3 in a 4-point scoring system. However, ventricular enhancement and the objective noise, signal-to-noise ratio, contrast-to-noise ratio and subjective image quality scores in group C were better than those in groups A and B (all P<.001). The effective radiation dose in groups A and B was 84% lower than that in group C (P<.001); group A received the lowest contrast dose (14% lower than that of groups B and C). Enhanced CT scan images with low dose radiation and low concentration contrast media can meet the diagnostic requirements for examining children with congenital heart disease while reducing the potential risk of radiation damage and contrast-induced nephropathy. © 2016 John Wiley & Sons Ltd.
Artifice, Interpretation and Nature: Key Categories in Radiology Work
NASA Astrophysics Data System (ADS)
Nyce, James M.
This paper extends on some prior work on nature, culture and computation. This paper will look at “image work” in a radiology department, i.e, how radiologists use images and other kinds of knowledge in daily clinical work. In particular, the paper will look at the role tacit knowledge and categories have in the work radiologists carry out. How radiologists make use of and contrast analog and digital representations of nature will be explored here because this is key to how radiologists work and think. In other words, the role that computer derived artifacts, correspondence theory and mimesis play in the clinical work of radiology will be discussed.
Teaching physics to radiology residents.
Hendee, William R
2009-04-01
The complexity of diagnostic imaging has expanded dramatically over the past two decades. Over the same period, the time and effort devoted to teaching physics (the science and technology of the discipline) have diminished. This paradox compromises the ability of future radiologists to master imaging technologies so that they are used in an efficient, safe, and cost-effective manner. This article addresses these issues. Efforts involving many professional organizations are under way to resolve the paradox of the expanding complexity of medical imaging contrasted with the declining emphasis on physics in radiology residency programs. These efforts should help to reestablish physics education as a core value in radiology residency programs.
Bilateral tuberculous otitis media: An unique presentation.
Bhatkar, Dhiraj; Utpat, Ketaki; Desai, Unnati; Joshi, Jyotsna M
2017-10-01
Tuberculous otitis media (TOM) is an uncustomary variety of tuberculosis (TB) usually seen secondary to pulmonary tuberculosis or associated with it. It is characterized by indolent and heterogeneous presentations. Diagnosis warrants clinical, radiological, and microbiological amalgamation. It is hence challenging and frequently delayed leading to disabling complications. Opportunate suspicion, timely diagnosis and appropriate antituberculosis therapy are the key to successful management. We report a unique case of bilateral TOM occurring in an immunocompetent adult. Copyright © 2016 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.
The principal activity at the NTS is testing of nuclear devices, though other related projects are also conducted. The principal activities of the Off-Site Radiological Safety Program are routine environmental monitoring for radioactive materials in various media and for radiatio...
A principal activity of the Offsite Radiological Safety Program is routine environmental monitoring for radioactive materials in various media and for radiation in areas which may be affected by nuclear tests. It is conducted to document compliance with standards, to identify tre...
Lee, Suh-Young; Yang, Min Suk; Choi, Young-Hoon; Park, Chang Min; Park, Heung-Woo; Cho, Sang Heon; Kang, Hye-Ryun
2017-03-01
Although the severity of hypersensitivity reactions to iodinated contrast media varies, it is well correlated with the severity of recurrent reactions; however, prophylaxis protocols are not severity-stratified. To assess the outcomes of tailored prophylaxis according to the severity of hypersensitivity reactions to iodinated contrast media. Our premedication protocols were stratified based on the severity of previous reactions: (1) 4 mg of chlorpheniramine for mild reactions, (2) adding 40 mg of methylprednisolone for moderate reactions, and (3) adding multiple doses of 40 mg of methylprednisolone for severe index reactions. Cases of reexposure in patients with a history of hypersensitivity reactions were routinely monitored and mandatorily recorded. Among a total of 850 patients who underwent enhanced computed tomography after severity-tailored prophylaxis, breakthrough reactions occurred in 17.1%, but most breakthrough reactions (89.0%) were mild and did not require medical treatment. Additional corticosteroid use did not reduce the breakthrough reaction rate in cases with a mild index reaction (16.8% vs 17.2%, P = .70). However, underpremedication with a single dose of corticosteroid revealed significantly higher rates of breakthrough reaction than did double doses of corticosteroid in cases with a severe index reaction (55.6% vs 17.4%, P = .02). Changing the iodinated contrast media resulted in an additional reduction of the breakthrough reaction rate overall (14.9% vs 32.1%, P = .001). In a total severity-based stratified prophylaxis regimens and changing iodinated contrast media can be considered in patients with a history of previous hypersensitivity reaction to iodinated contrast media to reduce the risk of breakthrough reactions. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Niederalt, Christoph; Wendl, Thomas; Kuepfer, Lars; Claassen, Karina; Loosen, Roland; Willmann, Stefan; Lippert, Joerg; Schultze-Mosgau, Marcus; Winkler, Julia; Burghaus, Rolf; Bräutigam, Matthias; Pietsch, Hubertus; Lengsfeld, Philipp
2013-01-01
A physiologically based kidney model was developed to analyze the renal excretion and kidney exposure of hydrophilic agents, in particular contrast media, in rats. In order to study the influence of osmolality and viscosity changes, the model mechanistically represents urine concentration by water reabsorption in different segments of kidney tubules and viscosity dependent tubular fluid flow. The model was established using experimental data on the physiological steady state without administration of any contrast media or drugs. These data included the sodium and urea concentration gradient along the cortico-medullary axis, water reabsorption, urine flow, and sodium as well as urea urine concentrations for a normal hydration state. The model was evaluated by predicting the effects of mannitol and contrast media administration and comparing to experimental data on cortico-medullary concentration gradients, urine flow, urine viscosity, hydrostatic tubular pressures and single nephron glomerular filtration rate. Finally the model was used to analyze and compare typical examples of ionic and non-ionic monomeric as well as non-ionic dimeric contrast media with respect to their osmolality and viscosity. With the computational kidney model, urine flow depended mainly on osmolality, while osmolality and viscosity were important determinants for tubular hydrostatic pressure and kidney exposure. The low diuretic effect of dimeric contrast media in combination with their high intrinsic viscosity resulted in a high viscosity within the tubular fluid. In comparison to monomeric contrast media, this led to a higher increase in tubular pressure, to a reduction in glomerular filtration rate and tubular flow and to an increase in kidney exposure. The presented kidney model can be implemented into whole body physiologically based pharmacokinetic models and extended in order to simulate the renal excretion of lipophilic drugs which may also undergo active secretion and reabsorption. PMID:23355822
Radiologically occult medulloblastoma with hydrocephalus: case report.
Honma, Hirokuni; Ogiwara, Hideki
2017-09-01
There have been no reports of occult medulloblastoma nor noncommunicating hydrocephalus due to radiologically occult brain tumors. Herein, we report radiologically occult medulloblastoma with noncommunicating hydrocephalus. A 3-year-old boy presented with macrocephaly, visual field constriction, and papilledema. Neuroimagings showed enlargement of the ventricles without any mass lesions. The CT cisternography did not show influx of the contrast into the ventricles, which suggested local cerebrospinal fluid (CSF) circulatory disturbance at the outlet of the fourth ventricle. Due to possible obstructive nature of hydrocephalus, endoscopic third ventriculostomy (ETV) was performed. Three months after the ETV, he presented with repeated vomiting. Neuroimagings showed a 3-cm fourth ventricular mass with progressive hydrocephalus. Surgical resection was performed, which revealed the pathology was medulloblastoma. We report the case of radiologically occult medulloblastoma which was demonstrated radiologically in the follow-up period of ETV for noncommunicating hydrocephalus of uncertain etiology. This is the first description of a radiologically occult medulloblastoma and also the first description of an occult brain tumor with noncommunicating hydrocephalus. The occult brain tumor may be included in the etiology of hydrocephalus.
Sadat, Umar; Usman, Ammara; Gillard, Jonathan H; Boyle, Jonathan R
2013-12-10
This study sought to perform a systematic review with meta-analysis of randomized controlled trials comparing the use of ascorbic acid with placebo or other treatment options for the treatment of contrast induced-acute kidney injury (CI-AKI) in patients undergoing coronary angiography. CI-AKI remains the most widely discussed and debated topic in cardiovascular medicine, with its incidence increasing due to an increasing number of contrast media-enhanced radiological procedures being performed. MEDLINE, Embase, and Cochrane central databases were searched from inception to May 2013, without language restrictions. For a study to be selected, it had to report the incidence of CI-AKI as an outcome measure. Studies were excluded if at least 1 study arm did not have ascorbic acid administered alone or with saline solution hydration. Data were extracted by 1 author, and random checks were made by another author. Nine randomized, controlled trials reported data on the incidence of CI-AKI in 1,536 patients who had completed the trial and were included in the final analysis. Patients receiving ascorbic acid had 33% less risk of CI-AKI compared with patients receiving placebo or an alternate pharmacological treatment (risk ratio by random-effects model: 0.672; 95% confidence interval, 0.466 to 0.969; p = 0.034). Ascorbic acid provides effective nephroprotection against CI-AKI and may form a part of effective prophylactic pharmacological regimens. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Dimitriou, Nikoletta; Panteleimonitis, Sofoklis; Dhillon, Ajit; Boyle, Kirsten; Norwood, Mike; Hemingway, David; Yeung, Justin; Miller, Andrew
2015-12-04
The aims of the study were to determine the radiological leak rate in those patients who had undergone a resection for left-sided colorectal cancer and to see if the presence of a leak can be related with the postoperative clinical period. We also aimed to identify any common factors between patients with leak. A retrospective analysis of prospectively collected data of all patients who underwent a left-sided colorectal cancer resection with formation of a defunctioning ileostomy was undertaken. Between 2005 and 2010, 418 such patients were identified. A water-soluble contrast enema was performed in 339 patients (81.1 %). Of these, 24 (7.1 %) were reported to show an anastomotic leak. Data for these 24 patients is presented in this study. Twenty-three (95.8 %) of the leaks occurred in patients who had undergone an anterior resection; 95.8 % of the patients with a leak were male. Fifteen (62.5 %) patients underwent neo-adjuvant radiation. The mean length of stay in those patients shown to have a subsequent radiological leak was 18.8 days (median), compared with the overall unit figures of 12 days. Only 29.2 % of the patients who had a leak identified had an uncomplicated postoperative period. Overall 87.5 % of the patients had a reversal of the ileostomy. Radiological leakage is not uncommon. The majority of patients, who were shown to have a radiological leak in this study, were male, had undergone an anterior resection, had received neo-adjuvant radiation, had a longer initial length of stay and had postoperative complications. Water-soluble contrast enemas could be selectively used in patients with these characteristics.
Park, Yu Jin; Rim, John Hoon; Yim, Jisook; Lee, Sang-Guk; Kim, Jeong-Ho
2017-08-01
The use of iodinated contrast media has grown in popularity in the past two decades, but relatively little attention has been paid to the possible interferential effects of contrast media on laboratory test results. Herein, we investigate medical contrast media interference with routine chemistry results obtained by three automated chemistry analyzers. Ten levels of pooled serum were used in the study. Two types of medical contrast media [Iopamiro (iopamidol) and Omnipaque (iohexol)] were evaluated. To evaluate the dose-dependent effects of the contrast media, iopamidol and iohexol were spiked separately into aliquots of serum for final concentrations of 1.8%, 3.6%, 5.5%, 7.3%, and 9.1%. The 28 analytes included in the routine chemistry panel were measured by using Hitachi 7600, AU5800, and Cobas c702 analyzers. We calculated the delta percentage difference (DPD) between the samples and the control, and examined dose-dependent trends. When the mean DPD values were compared with the reference cut-off criteria, the only uniformly interferential effect observed for all analyzers was in total protein with iopamidol. Two additional analytes that showed trends toward interferential effects only in few analyzers and exceeded the limits of the allowable error were the serum iron and the total CO 2 . The other combinations of analyzer and contrast showed no consistent dose-dependent propensity for change in any analyte level. Our study suggests that many of the analytes included in routine chemistry results, except total protein and serum iron, are not significantly affected by iopamidol and iohexol. These results suggest that it would be beneficial to apply a flexible medical evaluation process for patients requiring both laboratory tests and imaging studies, minimizing the need for strict regulations for sequential tests. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Mansoori, Bahar; Vidal, Lorenna L; Applegate, Kimberly; Rawson, James V; Novak, Ronald D; Ros, Pablo R
2013-10-01
The Patient Protection and Affordable Care Act (ACA) generated significant media attention since its inception. When the law was approved in 2010, the U.S. health care system began facing multiple changes to adapt and to incorporate measures to meet the new requirements. These mandatory changes will be challenging for academic radiology departments (ARDs) since they will need to promote a shift from a volume-focused to a value-focused practice. This will affect all components of the mission of ARDs, including clinical practice, education, and research. A unique key element to success in this transition is to focus on both quality and safety, thus improving the value of radiology in the post-ACA era. Given the changes ARDs will face during the implementation of ACA, suggestions are provided on how to adapt ARDs to this new environment. Copyright © 2013. Published by Elsevier Inc.
Modes of information delivery in radiologic anatomy education: Impact on student performance.
Ketelsen, Dominik; Schrödl, Falk; Knickenberg, Inés; Heckemann, Rolf A; Hothorn, Torsten; Neuhuber, Winfried; Bautz, Werner A L; Grunewald, Markus
2007-01-01
This study provides a systematic assessment of different methods of delivering radiologic teaching content (lecture, printed text, and digital content delivery) under standard conditions, enabling comparison of the effectiveness of these methods. A printed atlas of sectional anatomy was used as a standard. Digital content was developed on the basis of the printed atlas. Lecturers used both the printed and the digital content to prepare lectures. Standardized teaching material thus created was presented to second-term undergraduate students who had attended the school's anatomy course, but had not received any radiology teaching. Multiple choice examinations were used to assess the students' ability to recognize anatomical structures in known as well as unknown images. In a survey, the students' subjective experience of the learning process was assessed. No difference was seen between the groups regarding examination results. Students preferred a combination of digital media and lectures by enthusiastic teachers. The shortage of teachers requires a compromise concerning the delivery of radiologic anatomy content in a medical school setting. Based on our results, we recommend a combined approach of lecture and digital content delivery.
MR contrast media for myocardial viability, microvascular integrity and perfusion.
Saeed, M; Wendland, M F; Watzinger, N; Akbari, H; Higgins, C B
2000-06-01
Cardiovascular imaging requires an appreciation of rapidly evolving MR imaging sequences as well as careful utilization of intravascular, extracellular and intracellular MR contrast media. At the present time, clinical studies are restricted to the use of extracellular MR contrast media. MR imaging has the potential to noninvasively measure multiple parameters of the cardiovascular system in a single imaging session. Recent advances in fast and ultrafast MR imaging have considerably enhanced the capability of this technique, beyond the assessment of left ventricular wall motion and morphology into visualization of the coronary arteries and measurement of blood flow. During the course of the last several years, multiple strategies for imaging viable myocardium have been developed and validated using MR contrast media. Contrast enhanced dynamic MR imaging provides information regarding microvascular integrity and perfusion. Because these information can be provided noninvasively by MR imaging, repeated measurements can be performed in longitudinal studies to monitor the progression or regression of myocardial injury. Similar studies are needed to examine the effects of newly developed cardioprotective therapeutics. Development of suitable intravascular MR contrast medium may be essential for visualization of the coronary arteries and interventional therapies. MR imaging may emerge as one-stop-shop for evaluating the heart and coronary system. This capability will make MR imaging cost-effective in the first decade of this millennium.
Rubin, Zachary; Blackham, Kristine
2015-04-01
This study describes the state of preclinical radiology curricula in North American allopathic, osteopathic, and podiatric medical schools. An online survey of teaching methods, radiology topics, and future plans was developed. The Associations of American Medical Colleges, Colleges of Osteopathic Medicine, and Colleges of Podiatric Medicine listing for all US, Canadian, and Puerto Rican schools was used for contact information for directors of anatomy and/or radiology courses. Letters were sent via e-mail to 198 schools, with a link to the anonymous survey. Of 198 schools, 98 completed the survey (48%). Radiology curricula were integrated with other topics (91%), and taught by anatomists (42%) and radiologists (43%). The majority of time was spent on the topic of anatomy correlation (35%). Time spent teaching general radiology topics in the curriculum, such as physics (3%), modality differences (6%), radiation safety (2%), and contrast use (2%) was limited. Most schools had plans to implement an innovative teaching method in the near future (62%). The major challenges included limits on: time in the curriculum (73%); resources (32%); and radiology faculty participation (30%). A total of 82% reported that their curriculum did not model the suggestions made by the Alliance of Medical Student Educators in Radiology. This survey describes the current state of preclinical radiology teaching: curricula were nonstandard, integrated into other courses, and predominantly used for anatomy correlation. Other important contextual principles of the practice of radiology were seldom taught. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Cope, L H; Drinkwater, K J; Howlett, D C
2017-12-01
To determine radiology departmental compliance with current UK guidance on contrast-induced acute kidney injury (CI-AKI) and to provide data on the incidence of clinically significant post-contrast AKI (PC-AKI) in computed tomography (CT) practice. A questionnaire was sent to all UK acute National Health Service (NHS) providers (NHS boards in Scotland, local health boards in Wales, NHS trusts in England and health and social care trusts in Northern Ireland) to assess compliance of provider protocols with current UK guidelines for the prevention, recognition, and management of CI-AKI. Audit data were collected for 40 consecutive fit outpatients and 40 consecutive acutely unwell patients/inpatients from hospitals within each participating provider to assess clinical compliance. Eighty-nine of 172 (52%) health service providers responded, and data on 7,159 contrast-enhanced CT examinations were provided. Compliance with guidelines was poor with wide variation in clinical practice. The observed incidence of clinically significant (requiring treatment or resulting in death) PC-AKI was zero in 3,590 outpatients, although two patients developed AKI due to other causes (sepsis and progressive malignancy). Fourteen out of 3,569 (0.4%) patients in the inpatient group developed clinically significant PC-AKI, and a further 17 patients were identified who met the Kidney Disease Improving Global Outcomes (KDIGO) definition of AKI (Electronic Supplementary Material Appendix S1), but did not require active treatment, giving an overall incidence of AKI of 0.9%. In patients at high risk due to impaired renal function prior to the scan, there was no difference in the median serum creatinine (SCr) before and after contrast medium administration in either group. Health service provider protocols and clinical practice demonstrate poor compliance with current UK guidance on CI-AKI. A very low incidence of PC- AKI was demonstrated. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Deftereos, Spyridon; Giannopoulos, Georgios; Kossyvakis, Charalampos; Raisakis, Konstantinos; Kaoukis, Andreas; Driva, Metaxia; Ntzouvara, Olga; Panagopoulou, Vasiliki; Rentoukas, Ilias; Nikas, Dimitrios J; Pyrgakis, Vlasios; Alpert, Martin A
2009-09-01
The effects of radiographic contrast media on markers of complement activation and apoptosis in patients with chronic coronary artery disease (CAD) are unknown. The purpose of this study was to assess the comparative effects of ionic high-osmolar and non-ionic iso-osmolar radiographic contrast media on plasma markers of complement activation and apoptosis in patients with chronic CAD undergoing coronary angiography. Forty-four patients undergoing coronary angiography for chronic CAD were randomly assigned to receive the ionic high-osmolar radiographic contrast agent diatrizoate (Group A), or the non-ionic iso-osmolar contrast agent iodixanol (Group B) during angiography. Complement component 5 (C5a) and apoptotic markers sFas and sFasL were measured just prior to angiography and 1 hour after completion of angiography. Comparison of mean pre- and post-angiography plasma marker levels showed significantly greater increases in plasma levels in Group A than in Group B of C5a (29.30 +/- 5.45 ng/ml for Group A and 0.47 +/- 0.70 ng/ml for Group B (p < 0.00001), sFas (2.36 +/- 1.63 ng/ml for Group A and 0.23 +/- 0.90 ng/ml for Group B (p < 0.00001) and sFasL (14.00 +/- 5.41 pg/ml for Group A and 0.01 +/- 1.00 pg/ml for Group B (p < 0.00001). The results suggest that in patients with chronic CAD, the use of ionic high-osmolar radiographic contrast media during coronary angiography is associated with a more robust inflammatory and apoptotic milieu than that associated with the use of non-ionic iso-osmolar radiographic contrast media.
NASA Astrophysics Data System (ADS)
Mesbahi, Asghar; Famouri, Fatemeh; Ahar, Mohammad Johari; Ghaffari, Maryam Olade; Ghavami, Seyed Mostafa
2017-03-01
Aim: In the current study, some imaging characteristics of AuNPs were quantitatively analyzed and compared with two conventional contrast media (CM) including Iodine and Gadolinium by using of a cylindrical phantom. Methods: AuNPs were synthesized with the mean diameter of 16 nm and were equalized to the concentration of 0.5, 1, 2 and 4 mg/mL in the same volumes. A cylindrical phantom resembling the head and neck was fabricated and drilled to contain small tubes filled with Iodine, Gadolinium, and AuNPs as contrast media. The phantom was scanned in different exposure techniques and CT numbers of three studied contrast media inside test tubes were measured in terms of Hounsfield Unit (HU). The imaging parameters of the noise and contrast to noise ratios (CNR) were calculated for all studied CMs. Results: AuNPs showed 128% and 166% higher CT number in comparison with Iodine and Gadolinium respectively. Also, Iodine had a greater CT number than Gadolinium for the same exposure techniques and concentration. The maximum CT number for AuNPs and studied contrast materials was obtained at the highest mAs and the lowest tube potential. The maximum CT number were 1033±11 (HU) for AuNP, 565±10 (HU) for Iodine, 458±11 for Gadolinium. Moreover, the maximum CNRs of 433±117, 203±53, 145±37 were found for AuNPs, Iodine and Gadolinium respectively. Conclusion: The contrast agent based on AuNPs showed higher imaging quality in terms of contrast and noise relative to other iodine and gadolinium based contrast media in X-ray computed tomography. Application of the AuNPs as a contrast medium in x-ray CT is recommended.
Grimm, Lars J; Lowell, Dorothy A; Cater, Sarah W; Yoon, Sora C
2017-10-01
The purpose of this study is to determine how the motivations to pursue a career in radiology differ by gender. In addition, the influence of medical school radiology education will be assessed. Radiology applicants to our institution from the 2015-2016 interview season were offered an online survey in February 2016. Respondents scored the influence of 24 aspects of radiology on their decision to pursue radiology. Comparisons were made between male and female respondents. Respondents were also asked the type of medical school radiology education they received and to score the influence this experience had on their decision to pursue radiology. There were 202 total respondents (202/657) including 47 women and 155 men. Compared to men, the following factors had a more negative impact on women: flexible work hours (P = 0.04), work environment (P = 0.04), lifestyle (P = 0.04), impact on patient care (P = 0.05), high current debt load (P = 0.02), gender distribution of the field (P = 0.04), and use of emerging/advanced technology (P = 0.02). In contrast, women felt more favorably about the opportunities for leadership (P = 0.04) and research (P < 0.01). Dedicated radiology exposure was as follows: 20% (n = 20) none, 48% (n = 96) preclinical exposure, 55% (n = 111) elective rotation, and 18% (n = 37) core rotation. More intensive radiology exposure via a core rotation had a significantly positive impact on the decision to pursue radiology (P < 0.01). Male and female radiology applicants are motivated by different aspects of radiology, which may influence residency recruitment practices. In addition, more intensive radiology exposure has a net positive impact on the decision to pursue radiology. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Defense Threat Reduction Agency > About > Media > News
event Apr 4 - Pacific Soldiers build relationships through radiological training taught by DTRA, 10th fighting method for DTRA Feb 10 - USAF commissions Boeing to build more MOPs - 30,000 lb. extreme bunker Malaysia may build bombs with radioactive materials Stay Connected About DoD Top Issues News Photos &
Non-destructive in-situ method and apparatus for determining radionuclide depth in media
Xu, X. George; Naessens, Edward P.
2003-01-01
A non-destructive method and apparatus which is based on in-situ gamma spectroscopy is used to determine the depth of radiological contamination in media such as concrete. An algorithm, Gamma Penetration Depth Unfolding Algorithm (GPDUA), uses point kernel techniques to predict the depth of contamination based on the results of uncollided peak information from the in-situ gamma spectroscopy. The invention is better, faster, safer, and/cheaper than the current practice in decontamination and decommissioning of facilities that are slow, rough and unsafe. The invention uses a priori knowledge of the contaminant source distribution. The applicable radiological contaminants of interest are any isotopes that emit two or more gamma rays per disintegration or isotopes that emit a single gamma ray but have gamma-emitting progeny in secular equilibrium with its parent (e.g., .sup.60 Co, .sup.235 U, and .sup.137 Cs to name a few). The predicted depths from the GPDUA algorithm using Monte Carlo N-Particle Transport Code (MCNP) simulations and laboratory experiments using .sup.60 Co have consistently produced predicted depths within 20% of the actual or known depth.
Compression for radiological images
NASA Astrophysics Data System (ADS)
Wilson, Dennis L.
1992-07-01
The viewing of radiological images has peculiarities that must be taken into account in the design of a compression technique. The images may be manipulated on a workstation to change the contrast, to change the center of the brightness levels that are viewed, and even to invert the images. Because of the possible consequences of losing information in a medical application, bit preserving compression is used for the images used for diagnosis. However, for archiving the images may be compressed to 10 of their original size. A compression technique based on the Discrete Cosine Transform (DCT) takes the viewing factors into account by compressing the changes in the local brightness levels. The compression technique is a variation of the CCITT JPEG compression that suppresses the blocking of the DCT except in areas of very high contrast.
Saade, Charbel; Al-Hamra, Salam; Al-Mohiy, Hussain; El-Merhi, Fadi
2016-05-01
A patient with a history of mitral valve prolapse and regurgitation that was corrected with a mitral ring repair 15 years earlier received a diagnosis of anomalous left coronary artery arising from the pulmonary artery and underwent repair. Coronary computed tomography angiography (CTA) was employed to image the patient before surgical intervention. Synchronizing contrast media administration to opacify the right coronary artery in the arterial phase and the left coronary artery in the venous phase required a test-bolus approach. Matching compromised cardiovascular dynamics with patient-specific contrast media administration protocols was improved considerably with the use of a test-bolus technique during electrocardiography-gated coronary CTA.
Pseudo-hemothorax at computed tomography due to residual contrast media.
Romero, Matías; Bächler, Pablo
2014-01-01
Pleural effusion is a clinical problem that has many causes, with hemothorax being one of them. Computed tomography readily characterizes pleural fluid with determination of the attenuation value, helping to distinguish hemothorax from other types of effusion. Herein, we report the case of a 67-year-old man with end-stage renal disease in which a high-density pleural effusion due to residual contrast media was misinterpreted as hemothorax. Radiologists should consider the possibility of contrast media retention when interpreting a high-density pleural effusion in patients with end-stage renal disease. Recognition of this entity is crucial to avoid misdiagnosis, which might lead to unnecessary testing or procedures. Copyright © 2014 Elsevier Inc. All rights reserved.
Spasojević-Dimitrijeva, Brankica; Kotur-Stevuljević, Jelena; Đukić, Milan; Paripović, Dušan; Miloševski-Lomić, Gordana; Spasojević-Kalimanovska, Vesna; Pavićević, Polina; Mitrović, Jadranka; Kostić, Mirjana
2017-01-01
Background New renal biomarkers such as neutrophil gelatinase-associated lipocalin (NGAL) and kidney injury molecule-1 (KIM-1) show promise in early diagnosis of contrast media induced acute kidney injury (CI-AKI). The purpose of our study was to compare the subclinical nephrotoxicity (a condition without changes in standard renal biomarkers) of gadolinium-based contrast media (Gd-DTPA, gadopentetate dimeglumine) and iodinated-based contrast media (iopromide) in pediatric patients with normal kidney function. Material/Methods The first group (n=58) of patients included in the study were undergoing angiography with iopromide, and the second group (n=65) were undergoing magnetic resonance (MR) angiography/urography with Gd-DTPA administration. The concentrations of NGAL and KIM-1 were measured four times in the urine (pre-contrast, then at four hours, 24 hours, and 48 hours after contrast administration), and serum NGAL was measured at 0 (baseline), 24 hours, and 48 hours after contrast exposure. Results After 24 hours, serum NGAL increase of ≥25% was noticed in 32.6% of the patients in the iopromide group and in 25.45% of the patients in the gadolinium group, with significantly higher average percent of this increase in first group (62.23% vs. 36.44%, p=0.002). In the Gd-DTPA group, we observed a statistically significant increase in urinary KIM-1 24 hours after the procedure. Normalized urinary KIM-1, 24 hours after contrast exposure, was a better predictive factor for CI-AKI than other biomarkers (AUC 0.757, cut off 214 pg/mg, sensitivity 83.3%, specificity 54.2%, p=0.035). Conclusions In children with normal renal function, exposure to iodinated-based and gadolinium-based media might lead to subclinical nephrotoxicity, which could be detected using serum NGAL and urinary KIM-1. PMID:28874655
Rossi, C; Reginelli, A; D'Amora, M; Di Grezia, G; Mandato, Y; D'Andrea, A; Brunese, L; Grassi, R; Rotondi, A
2014-01-01
The purpose of the study is to examine the incidence of adverse reactions caused by non-ionic contrast media in selected patients after desensitization treatment and to evaluate the safety profile of organ iodine contrast media (i.c.m.) in a multistep prevention protocol. In a population of 2000 patients that had received a CT scan, 100 patients with moderate/high risk for adverse reactions against iodinated contrast agents followed a premedication protocol and all adverse reactions are reported and classified as mild, moderate or severe. 1.7 percent of the pre-treated patients reported a mild, immediate type reaction to iodine contrast; of these five patients with allergy 0.71 percent had received iomeprol, 0.35 percent received ioversol and 0.71 percent received iopromide. The incidence of adverse reactions was reported to be higher (4 out of 5 patients) among those that referred a history of hypersensitivity against iodinated i.c.m. Although intravenous contrast materials have greatly improved, especially in terms of their safety profile, they should not be administered if there isn't a clear or justified indication. In conclusion, even if we know that the majority of these reactions are idiosyncratic and unpredictable we propose, with the aim of improving our knowledge on this subject, a multicenter study, based on skin allergy tests (prick test, patch test, intradermal reaction) in selected patients that have had previous experiences of hypersensitivity against parenteral organ iodine contrast media.
Transcatheter aortic-valve implantation with one single minimal contrast media injection.
Arrigo, Mattia; Maisano, Francesco; Haueis, Sabine; Binder, Ronald K; Taramasso, Maurizio; Nietlispach, Fabian
2015-06-01
Performing transcatheter aortic valve implantation (TAVI) with the use of minimal contrast in patients at high-risk for acute kidney injury (AKI). Contrast-induced nephropathy (CIN) is a major cause of AKI following TAVI and is associated with increased morbidity and mortality. The amount of contrast media used increases the risk for CIN. Computed tomography was omitted during the screening process. For the procedure transfemoral access was default. The self-expanding CoreValve prosthesis was chosen in all patients to minimize the risk of annular rupture in case of oversizing. Valve sizing was based on echocardiography, aortography, calcification on fluoroscopy, as well as weight and height of the patient. A single contrast injection was performed to confirm correct position of the pigtail catheter at the level of the annulus. The pigtail then served as the marker for the device landing zone. Intraprocedural assessment of the implantation result relied on echocardiography and hemodynamics. Five patients with severe aortic stenosis and at high risk for developing CIN were included. Device success was achieved in all patients and no major complications occurred. The median dose of injected contrast media was 8 ml (4-9). All but one patient had improved renal function after the intervention compared to baseline. Our study shows feasibility of performing TAVI with a single minimal contrast media injection, using a self-expandable valve. This technique has the potential to reduce the incidence of CIN. © 2015 Wiley Periodicals, Inc.
High resolution 3D MRI of mouse mammary glands with intra-ductal injection of contrast media
Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Roman, Brian B.; Jansen, Sanaz A.; Macleod, Kay; Conzen, Suzanne D.; Karczmar, Gregory S.
2014-01-01
The purpose of this study was to use high resolution 3D MRI to study mouse mammary gland ductal architecture based on intra-ductal injection of contrast agents. Female FVB/N mice age 12–20 weeks (n = 12), were used in this study. A 34G, 45° tip Hamilton needle with a 25uL Hamilton syringe was inserted into the tip of the nipple. Approximately 20–25uL of a Gadodiamide/Trypan blue/saline solution was injected slowly over one minute into the nipple and duct. To prevent washout of contrast media from ducts due to perfusion, and maximize the conspicuity of ducts on MRI, mice were sacrificed one minute after injection. High resolution 3D T1-weighted images were acquired on a 9.4T Bruker scanner after sacrifice to eliminate motion artifacts and reduce contrast media leakage from ducts. Trypan blue staining was well distributed throughout the ductal tree. MRI showed the mammary gland ductal structure clearly. In spoiled gradient echo T1-weighted images, the signal-to-noise ratio of regions identified as enhancing mammary ducts following contrast injection was significantly higher than that of muscle (p < 0.02) and significantly higher than that of contralateral mammary ducts that were not injected with contrast media (p < 0.0001). The methods described here could be adapted for injection of specialized contrast agents to measure metabolism or target receptors in normal ducts and ducts with in situ cancers. PMID:25179139
From, Aaron M; Al Badarin, Firas J; McDonald, Furman S; Bartholmai, Brian J; Cha, Stephen S; Rihal, Charanjit S
2010-08-01
Contrast-induced nephropathy (CIN) is associated with significant morbidity and mortality. The objective of our meta-analysis was to assess the efficacy of iodixanol compared with low-osmolar contrast media (LOCM) for prevention of CIN. We searched MEDLINE, the Cochrane Central Register of Controlled Trials, and internet sources of cardiology trial results for individual and relevant reviews of randomized, controlled trials, for the terms contrast media, contrast nephropathy, renal failure, iodixanol, Visipaque, and low-osmolar contrast media. All studies reported an incidence rate of CIN for each study group; there was no restriction on the definition of CIN. There were no restrictions on journal type or patient population. Overall, 36 trials were identified for analysis of aggregated summary data on 7166 patients; 3672 patients received iodixanol and 3494 patients received LOCM. Overall, iodixanol showed no statistically significant reduction in CIN incidence below that observed with heterogeneous comparator agents (P=0.11). Analysis of patient subgroups revealed that there was a significant benefit of iodixanol when compared with iohexol alone (odds ratio, 0.25; 95% confidence interval, 0.11 to 0.55; P<0.001) but not when compared with LOCM other than iohexol or with other ionic dimers or among patients receiving intra-arterial contrast injections or among patients undergoing coronary angiography with or without percutaneous intervention. Analysis of aggregated summary data from multiple randomized, controlled trials of iodixanol against diverse LOCMs for heterogeneous procedures and definitions of CIN show an iodixanol-associated reduction that is suggestive but statistically nonsignificant.
Bluth, Edward I; Muroff, Lawrence R; Cernigliaro, Joseph G; Moore, Arl V; Smith, Geoffrey G; Flug, Jonathan; DeStigter, Kristen K; Allen, Bibb; Thorwarth, William T; Roberts, Anne C
2015-05-01
The results of a survey sent to practice leaders in the ACR Practice of Radiology Environment Database show that the majority of responding groups will continue to hire recently trained residents and fellows even though they have been unable to take the final ABR diagnostic radiology certifying examination. However, a significant minority of private practice groups will not hire these individuals. The majority of private practices expect the timing change for the ABR certifying examinations to affect their groups' function. In contrast, the majority of academic medical school practices expect little or no impact. Residents and fellows should not expect work time off or protected time to study for the certifying examination or for their maintenance of certification examinations in the future. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Iodinated X-ray contrast media (ICMs), used in medical imaging, are poorly metabolized by humans and enter wastewater. As they are incompletely removed during wastewater treatment, ICMs are released to the aquatic environment and have been detected in drinking water sources. ICMs...
Nasrollah, Jabbari; Mikaeil, Molazadeh; Omid, Esnaashari; Mojtaba, Seyed Siahi; Ahad, Zeinali
2014-01-01
The impact of intravenous (IV) contrast media (CM) on radiation dose calculations must be taken into account in treatment planning. The aim of this study is to evaluate the effect of an intravenous contrast media on dose calculations in three-dimensional conformal radiation therapy (3D-CRT) for lower esophageal and rectal cancers. Seventeen patients with lower esophageal tumors and 12 patients with rectal cancers were analyzed. At the outset, all patients were planned for 3D-CRT based on the computed tomography (CT) scans with IV contrast media. Subsequently, all the plans were copied and replaced on the scans without intravenous CM. The radiation doses calculated from the two sets of CTs were compared. The dose differences between the planning image set using intravenous contrast and the image set without contrast showed an average increase in Monitor Units (MUs) in the lower esophageal region that was 1.28 and 0.75% for 6 and 15 MV photon beams, respectively. There was no statistical significant difference in the rectal region between the two sets of scans in the 3D-CRT plans. The results showed that the dose differences between the plans for the CT scans with and without CM were small and clinically tolerable. However, the differences in the lower esophageal region were significant in the statistical analysis.
Leroux, Lionel; Dijos, Marina; Dos Santos, Pierre
2013-12-01
Severe anaphylactoid reaction after the use of iodinated contrast media are rare but can contraindicate the use of contrast agent. It was the case of a 53-year-old woman suffering from symptomatic severe aortic stenosis, recused for cardiac surgery because of deleterious effects of chest-wall irradiation, with porcelain aorta. We decided to implant a 23-mm Edwards(®) SAPIEN(®) transcatheter aortic valve via a femoral route without using any contrast media. The implantation was successful after surgical approach of the femoral artery, transesophageal echocardiography guiding, and localization of native leaflets and coronary trunk with catheters. Immediate and one month post-interventional follow-up was favorable and echocardiography showed a good functioning of the aortic bioprosthesis. Although conventional angiography is the best way to visualize the good positioning of the valve before deployment, our case suggests that, in special situations, transfemoral implantation of an Edwards(®) SAPIEN(®) aortic bioprosthesis is feasible without any contrast injection. Copyright © 2012 Wiley Periodicals, Inc.
Simulation and source identification of X-ray contrast media in the water cycle of Berlin.
Knodel, J; Geissen, S-U; Broll, J; Dünnbier, U
2011-11-01
This article describes the development of a model to simulate the fate of iodinated X-ray contrast media (XRC) in the water cycle of the German capital, Berlin. It also handles data uncertainties concerning the different amounts and sources of input for XRC via source densities in single districts for the XRC usage by inhabitants, hospitals, and radiologists. As well, different degradation rates for the behavior of the adsorbable organic iodine (AOI) were investigated in single water compartments. The introduced model consists of mass balances and includes, in addition to naturally branched bodies of water, the water distribution network between waterways and wastewater treatment plants, which are coupled to natural surface waters at numerous points. Scenarios were calculated according to the data uncertainties that were statistically evaluated to identify the scenario with the highest agreement among the provided measurement data. The simulation of X-ray contrast media in the water cycle of Berlin showed that medical institutions have to be considered as point sources for congested urban areas due to their high levels of X-ray contrast media emission. The calculations identified hospitals, represented by their capacity (number of hospital beds), as the most relevant point sources, while the inhabitants served as important diffusive sources. Deployed for almost inert substances like contrast media, the model can be used for qualitative statements and, therefore, as a decision-support tool. Copyright © 2011 Elsevier Ltd. All rights reserved.
The health care value transparency movement and its implications for radiology.
Durand, Daniel J; Narayan, Anand K; Rybicki, Frank J; Burleson, Judy; Nagy, Paul; McGinty, Geraldine; Duszak, Richard
2015-01-01
The US health care system is in the midst of disruptive changes intended to expand access, improve outcomes, and lower costs. As part of this movement, a growing number of stakeholders have advocated dramatically increasing consumer transparency into the quality and price of health care services. The authors review the general movement toward American health care value transparency within the public, private, and nonprofit sectors, with an emphasis on those initiatives most relevant to radiology. They conclude that radiology, along with other "ancillary services," has been a major focus of early efforts to enhance consumer price transparency. By contrast, radiology as a field remains in the "middle of the pack" with regard to quality transparency. There is thus the danger that radiology value transparency in its current form will stimulate primarily price-based competition, erode provider profit margins, and disincentivize quality. The authors conclude with suggested actions radiologists can take to ensure that a more optimal balance is struck between quality transparency and price transparency, one that will enable true value-based competition among radiologists rather than commoditization. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Pediatric Voiding Cystourethrogram
... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... Disclaimer This information is copied from the RadiologyInfo Web site (http://www.radiologyinfo.org) which is dedicated ...
Keuffel, Eric; McCullough, Peter A; Todoran, Thomas M; Brilakis, Emmanouil S; Palli, Swetha R; Ryan, Michael P; Gunnarsson, Candace
2018-04-01
To determine the net economic impact of switching from low-osmolar contrast media (LOCM) to iso-osmolar contrast media (IOCM; iodixanol) in patients undergoing inpatient coronary or peripheral angioplasty in the United States (US). A budget impact model (BIM) was developed from a hospital perspective. Nationally representative procedural and contrast media prevalence rates, along with MARCE (major adverse renal cardiovascular event) incidence and episode-related cost data were derived from Premier Hospital Data (October 2014 to September 2015). A previously estimated relative risk reduction in MARCE associated with IOCM usage (9.3%) was applied. The higher cost of IOCM was included when calculating the net impact estimates at the aggregate, hospital type, and per hospital levels. One-way (±25%) and probabilistic sensitivity analyses identified the model's most important inputs. Based on weighted analysis, 513,882 US inpatient angioplasties and 35,610 MARCE cases were estimated annually. Switching to an "IOCM only" strategy from a "LOCM only" strategy increases contrast media cost, but prevents 2,900 MARCE events. The annual budget impact was an estimated saving of $30.71 million, aggregated across all US hospitals, $6,316 per hospital, or $60 per procedure. Net savings were maintained across all univariate sensitivity analyses. While MARCE/event-free cost differential was the most important factor driving total net savings for hospitals in the Northeast and West, procedural volume was important in the Midwest and rural locations. Switching to an "IOCM only" strategy from a "LOCM only" approach yields substantial net global savings to hospitals, both at the national level and within hospital sub-groups. Hospital administrators should maintain awareness of the factors that are likely to be more influential for their hospital and recognize that purchasing on the basis of lower contrast media cost may result in higher overall costs for patients undergoing inpatient angioplasty.
Shortcomings of low-cost imaging systems for viewing computed radiographs.
Ricke, J; Hänninen, E L; Zielinski, C; Amthauer, H; Stroszczynski, C; Liebig, T; Wolf, M; Hosten, N
2000-01-01
To assess potential advantages of a new PC-based viewing tool featuring image post-processing for viewing computed radiographs on low-cost hardware (PC) with a common display card and color monitor, and to evaluate the effect of using color versus monochrome monitors. Computed radiographs of a statistical phantom were viewed on a PC, with and without post-processing (spatial frequency and contrast processing), employing a monochrome or a color monitor. Findings were compared with the viewing on a radiological Workstation and evaluated with ROC analysis. Image post-processing improved the perception of low-contrast details significantly irrespective of the monitor used. No significant difference in perception was observed between monochrome and color monitors. The review at the radiological Workstation was superior to the review done using the PC with image processing. Lower quality hardware (graphic card and monitor) used in low cost PCs negatively affects perception of low-contrast details in computed radiographs. In this situation, it is highly recommended to use spatial frequency and contrast processing. No significant quality gain has been observed for the high-end monochrome monitor compared to the color display. However, the color monitor was affected stronger by high ambient illumination.
Chinnugounder, Sankar; Hippe, Daniel S; Maximin, Suresh; O'Malley, Ryan B; Wang, Carolyn L
2015-01-01
Although subjective and objective benefits of high-fidelity simulation have been reported in medicine, there has been slow adoption in radiology. The purpose of our study was to identify the perceived barriers in the use of high-fidelity hands-on simulation for contrast reaction management training. An IRB exempt 32 questions online web survey was sent to 179 non-military radiology residency program directors listed in the Fellowship and Residency Electronic Interactive Database Access system (FREIDA). Survey questions included the type of contrast reaction management training, cost, time commitment of residents and faculty, and the reasons for not using simulation training. Responses from the survey were summarized as count (percentage), mean ± standard deviation (SD), or median (range). 84 (47%) of 179 programs responded, of which 88% offered CRM training. Most (72%) conducted the CRM training annually while only 4% conducted it more frequently. Didactic lecture was the most frequently used training modality (97%), followed by HFS (30%) and computer-based simulation (CBS) (19%); 5.5% used both HFS and CBS. Of the 51 programs that offer CRM training but do not use HFS, the most common reason reported was insufficient availability (41%). Other reported reasons included cost (33%), no access to simulation centers (33%), lack of trained faculty (27%) and time constraints (27%). Although high-fidelity hands-on simulation training is the best way to reproduce real-life contrast reaction scenarios, many institutions do not provide this training due to constraints such as cost, lack of access or insufficient availability of simulation labs, and lack of trained faculty. As a specialty, radiology needs to better address these barriers at both an institutional and national level. Copyright © 2015 Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Crum, Ryan; Pagan, Darren; Lind, Jon; Homel, Michael; Hurley, Ryan; Herbold, Eric; Akin, Minta
Granular systems are ubiquitous in our everyday world and play a central role in many dynamic scientific problems including mine blasting, projectile penetration, astrophysical collisions, explosions, and dynamic compaction. An understanding of granular media's behavior under various loading conditions is an ongoing scientific grand challenge. This is partly due to the intricate interplay between material properties, loading conditions, grain geometry, and grain connectivity. Previous dynamic studies in granular media predominantly utilize the macro-scale analyses VISAR or PDV, diagnostics that are not sensitive to the many degrees of freedom and their interactions, focusing instead on their aggregate effect. Results of a macro-scale analysis leave the principal interactions of these degrees of freedom too entangled to elucidate. To isolate the significance of grain geometry, this study probes various geometries of granular media subjected to gas gun generated waves via in-situ X-ray analysis. Analyses include evaluating displacement fields, grain fracture, inter- and intra-granular densification, and wave front motion. Phase Contrast Imaging (PCI) and PDV analyses feed directly into our concurrent meso-scale granular media modeling efforts to enhance our predictive capabilities.
Garrett, Kevin M; Levitt, Marc A; Peña, Alberto; Kraus, Steven J
2012-09-01
The radiologic evaluation of Hirschsprung disease is well described in the literature. However, there is a paucity of literature describing the appearance of the neo-rectum and colon after repair, specifically describing findings in patients with poor functional outcome, which would suggest the need for reoperation. We describe findings on contrast enema and correlate them with surgical findings at reoperation in children with poor functional outcome after primary repair for Hirschsprung disease who suffer from bowel dysfunction that can manifest with either soiling or obstructive symptoms such as enterocolitis. Children were identified from our colorectal surgery database. At the time of abstract submission, 35 children had contrast enemas prior to reoperation. Additional children continue to present for evaluation. The majority of children included in the study had their primary repair performed elsewhere. The initial procedures included: Duhamel (n = 11), Soave (n = 20) or Swenson (n = 3). One child had undergone a primary Soave repair and subsequently had a Swenson-type reoperation but continued to have a poor outcome. One child's initial surgical repair could not be determined. Images were reviewed by a staff pediatric radiologist and a pediatric radiology fellow. Findings encountered on contrast enema in these children include a distal narrowed segment due to stricture or aganglionic/transitional zone segment (8), dilated/hypomotile distal segment (7), thickened presacral space due to compressing Soave cuff (11), dilated Duhamel pouch (8), active enterocolitis (3) and partially obstructing twist of the pull-through segment (1). Multiple anatomical and pathological complications exist that can lead to bowel dysfunction in children after repair of Hirschsprung disease. Little recent literature exists regarding the radiographic findings in children. We had the opportunity to review a substantial series of these children, describe the contrast enema findings in these difficult cases and correlate them with operative findings. Radiologic evaluation is key to assessing such patients; it defines the potential anatomical problem with the pull-through and facilitates surgical planning.
Fukushima Daiichi Accident and Its Radiological Impact on the Environment
ERIC Educational Resources Information Center
Bevelacqua, J. J.
2012-01-01
The Fukushima Daiichi nuclear accident is a topic of current media and public interest. It provides a means to motivate students to understand the fission process and the barriers that have been designed to prevent the release of fission products to the environment following a major nuclear power reactor accident. The Fukushima Daiichi accident…
[Progress in the early diagnosis of cancer of the colon and rectum].
Canessa, N; Roset, J; Boffi, A; Ferrara, J B; Galano, A; Albertengo, J C
1978-09-01
Our experience with the air contrast examination in the cancer of colon and rectum diagnoses is showed. The colaboration among radiologist, endoscopist, pathologist and surgeon is important. In the large bowel tumors diagnosis, the radiologic and endoscopic prodedures should be evaluated together. The double colonic contrast has showed in our experience, better results than with the barium enema. Over 31 patients with both studies, we obtained 13 false negatives (with barium enema, doing then the double colonic contrast became positive 12 (92.4%).
Self-expandable CoreValve implantation without contrast media.
Bruschi, Giuseppe; Colombo, Paola; De Marco, Federico; Barosi, Alberto; Mauri, Silvia; Klugmann, Silvio
2016-09-01
Transcatheter aortic valve implantation has been designed to treat high-risk surgical patients affected by severe aortic stenosis, many of whom are affected by chronic kidney disease. To perform transcatheter self-expandable valve implantation, multiple contrast injections are required to monitor the procedure, so these patients are at increased risk of acute kidney injury. We described self-expandable transcatheter aortic valve implantation without contrast media in an 80-year-old man affected by severe aortic stenosis and endstage chronic kidney disease. © The Author(s) 2015.
Physicochemical properties of radiographic contrast media, potential nephrotoxicity and prophylaxis.
Hogstrom, Barry; Ikei, Nobuhiro
2015-12-01
Contrast induced nephropathy (CIN) remains a controversial topic. The clinical relevance of changes in laboratory parameters has been challenged; some authors have even suggested that CIN simply reflects natural fluctuations. Other areas of controversy include the pathophysiology of CIN, effectiveness of prophylactic approaches and differences in nephrotoxicity between individual contrast media (CM). The aim of this review is to summarize the current understanding of laboratory findings and explore its relationship to CM toxicity. © 2015 Wiley Publishing Asia Pty Ltd.
[Iodinated contrast media and iodine allergy: myth or reality?].
Meunier, B; Joskin, J; Damas, F; Meunier, P
2013-09-01
The term "iodine allergy" is an old phrase that refers to a reaction to iodinated contrast media. After a brief review of definitions, pathophysiological mechanisms and risk factors of this clinical entity, management is urged immediate and delayed according to the most recent recommendations from the literature. We underline that iodine allergy, as such, does not really exist.
Phase contrast: the frontier of x-ray and electron imaging
NASA Astrophysics Data System (ADS)
Hwu, Y.; Margaritondo, G.
2013-12-01
Phase contrast has been a fundamental component of microscopy since the early 1940s. In broad terms, it refers to the formation of images using not the combination of wave intensities but their amplitudes with the corresponding phase factors. The impact on visible microscopy of biological specimens has been major. This contrast mechanism is now playing an increasingly important role in other kinds of microscopy, notably those based on electrons or x-rays. It notably solves the background problem of weak absorption contrast. New breakthroughs and new techniques are continuously produced, unfortunately unknown to most of the scientists that could exploit them. The present special cluster issue of reviews was inspired by this situation. The case of x-rays is very interesting. Phase contrast requires a high degree of longitudinal and lateral coherence. But conventional x-ray sources are not coherent. The progress of synchrotron sources yielded high coherence as a key byproduct—and started a rapid expansion of phase contrast radiology. No review—or cluster of reviews—can possibly cover all the facets of the recent progress. Without trying to be absolutely comprehensive, the present special cluster issue touches a variety of issues, giving a very broad picture. Liu et al review in general terms the different phase-based hard-x-ray techniques, with an interesting variety of examples. Then, Suortti et al and Wang et al present more specialized overviews of crystal and grating based x-ray imaging techniques, very powerful in the analysis of biological specimens. Mokso et al discuss the many facets of tomography using phase effects, expanding the picture of tomographic reconstruction of the three previous reviews. Wu et al treat the rapid progress in hard-x-ray focusing and its impact on radiology and tomography for materials science and biomedical research. The next two reviews deal with special and very interesting classes of applications. Specifically, Lee et al discuss the use of the new radiology techniques in the study of liquids, and Coan et al present the progress in phase-contrast radiology analysis of real patients. Although x-ray imaging is the main focus of the special cluster issue, the picture would not be complete without a view on the parallel and very exciting developments in electron microscopy. The last review, by Wu et al , is dedicated indeed to this broader picture, presenting recent progress in Zernike-related electron phase contrast. We trust that the special cluster issue will not only update readers on the evolution of a very important class of experimental techniques, but also prepare them for the forthcoming developments. We are indeed at the threshold of another revolution. The recently inaugurated first x-ray free electron lasers bring, together with many other record performances, full lateral coherence and excellent longitudinal coherence. The first imaging experiments show in practice their impact, and indicate that this field, far from saturating its progress, is ready for new major breakthroughs.
High resolution 3D MRI of mouse mammary glands with intra-ductal injection of contrast media.
Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Roman, Brian B; Jansen, Sanaz A; Macleod, Kay; Conzen, Suzanne D; Karczmar, Gregory S
2015-01-01
The purpose of this study was to use high resolution three-dimensional (3D) magnetic resonance imaging (MRI) to study mouse mammary gland ductal architecture based on intra-ductal injection of contrast agents. Female FVB/N mice age 12-20 weeks (n=12), were used in this study. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple. Approximately 20-25μL of a Gadodiamide/Trypan blue/saline solution was injected slowly over one minute into the nipple and duct. To prevent washout of contrast media from ducts due to perfusion, and maximize the conspicuity of ducts on MRI, mice were sacrificed one minute after injection. High resolution 3D T1-weighted images were acquired on a 9.4T Bruker scanner after sacrifice to eliminate motion artifacts and reduce contrast media leakage from ducts. Trypan blue staining was well distributed throughout the ductal tree. MRI showed the mammary gland ductal structure clearly. In spoiled gradient echo T1-weighted images, the signal-to-noise ratio of regions identified as enhancing mammary ducts following contrast injection was significantly higher than that of muscle (p<0.02) and significantly higher than that of contralateral mammary ducts that were not injected with contrast media (p<0.0001). The methods described here could be adapted for injection of specialized contrast agents to measure metabolism or target receptors in normal ducts and ducts with in situ cancers. Copyright © 2014 Elsevier Inc. All rights reserved.
Extranasopharyngeal angiofibroma: clinical and radiological presentation.
Szymańska, Anna; Szymański, Marcin; Morshed, Kamal; Czekajska-Chehab, Elżbieta; Szczerbo-Trojanowska, Małgorzata
2013-02-01
Nasopharyngeal angiofibroma (NA) is a rare, vascular tumor affecting adolescent males. Due to aggressive local growth, skull base location and risk of profound hemorrhage, NA is a challenge for surgeons. Angiofibromas have been sporadically described in extanasopharyngeal locations. We review ten cases of extranasopharyngeal angiofibroma (ENA) and discuss the incidence, clinical presentation and management of this pathology. The group consisted of 4 males and 5 females aged 8-49. There were 7 patients with nasal angiofibroma, 1 patient with laryngeal angiofibroma, 1 patient with oral angiofibroma and another patient with infratemporal fossa tumor. In patients with nasal angiofibroma most common presenting symptoms were nasal obstruction and epistaxis. Patients with laryngeal angiofibroma suffered from mild dysphagia and patients with the infratemporal fossa tumor had painless cheek swelling. In four patients with nasal tumor computed tomography (CT) demonstrated mass with strong to intermediate contrast enhancement. In one patient with nasal tumor carotid angiography demonstrated pathological vessels without intensive tumor blush. Infratemporal fossa tumor showed intensive contrast enhancement on CT and magnetic resonance imaging (MRI) scans, and abundant vascularity on angiography. Laryngeal and oral angiofibroma required no radiological imaging. Three nasal tumors were evaluated before introduction of CT to clinical practice. All patients underwent surgery. No recurrences developed. ENAs differ significantly from NAs regarding clinical and radiological presentations. They lack typical clinical and radiological features as they develop in all age groups and in females, may be less vascularised, arise from various sites and produce a variety of symptoms.
Biondi-Zoccai, Giuseppe; Lotrionte, Marzia; Thomsen, Henrik S; Romagnoli, Enrico; D'Ascenzo, Fabrizio; Giordano, Arturo; Frati, Giacomo
2014-03-15
Contrast-induced nephropathy (CIN) may be a severe complication to the administration of iodine-based contrast media for diagnostic or interventional procedure using radiation exposure. Whether there is a difference in nephrotoxic potential between the various agents is uncertain. We aimed to perform a systematic review and network meta-analysis of randomized trials on iodine-based contrast agents. Randomized trials of low-osmolar or iso-osmolar contrast media were searched in CENTRAL, Google Scholar, MEDLINE/PubMed, and Scopus. Risk of CIN was appraised within a hierarchical Bayesian model computing absolute rates (AR) and odds ratios (OR) with 95% credibility intervals, and probability of being best (Pbest) for each agent. A total of 42 trials (10048 patients) were included focusing on 7 different iodine-based contrast media. Risk of CIN was similarly low with iodixanol (AR=5.7% [2.2%-13.9%], Pbest=18.8%), iomeprol (AR=6.0% [2.2%-15.4%], Pbest=24.8%), iopamidol (AR=6.1% [2.2%-15.5%], Pbest=21.5%), and ioversol (AR=6.0% [2.1%-16.4%], Pbest=31.3%). Conversely, CIN was twice as common with iohexol (AR=11.2% [4.1%-29.5%], Pbest=0.1%) and ioxaglate (AR=11.0% [4.0%-26.9%], Pbest<0.1%), with both proving less safe than iodixanol (respectively OR=2.18 [1.22-3.92] and 2.05 [1.26-3.29]), iomeprol (OR=2.08 [1.04-4.17] and 1.96 [1.06-3.48]) and iopamidol (OR=2.04 [1.15-3.85] and 1.92 [1.06-3.45]). Data on iopromide were less conclusive (AR=6.9% [2.6%-17.1%], Pbest=3.6%). Iodixanol, iomeprol, iopamidol and ioversol are iodine-based contrast media with a similar renal safety profile. Iohexol and ioxaglate have a poorer renal safety profile, whereas further data may be required on iopromide. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Erb-Eigner, Katharina; Taupitz, Matthias; Asbach, Patrick
2016-01-01
The purpose of this study was to compare contrast and image quality of whole-body equilibrium-phase high-spatial-resolution MR angiography using a non-protein-binding unspecific extracellular gadolinium-based contrast medium with that of two contrast media with different protein-binding properties. 45 patients were examined using either 15 mL of gadobutrol (non-protein-binding, n = 15), 32 mL of gadobenate dimeglumine (weakly protein binding, n = 15) or 11 mL gadofosveset trisodium (protein binding, n = 15) followed by equilibrium-phase high-spatial-resolution MR-angiography of four consecutive anatomic regions. The time elapsed between the contrast injection and the beginning of the equilibrium-phase image acquisition in the respective region was measured and was up to 21 min. Signal intensity was measured in two vessels per region and in muscle tissue. Relative contrast (RC) values were calculated. Vessel contrast, artifacts and image quality were rated by two radiologists in consensus on a five-point scale. Compared with gadobutrol, gadofosveset trisodium revealed significantly higher RC values only when acquired later than 15 min after bolus injection. Otherwise, no significant differences between the three contrast media were found regarding vascular contrast and image quality. Equilibrium-phase high-spatial-resolution MR-angiography using a weakly protein-binding or even non-protein-binding contrast medium is equivalent to using a stronger protein-binding contrast medium when image acquisition is within the first 15 min after contrast injection, and allows depiction of the vasculature with high contrast and image quality. The protein-binding contrast medium was superior for imaging only later than 15 min after contrast medium injection. Copyright © 2015 John Wiley & Sons, Ltd.
Radiological Dispersion Devices and Basic Radiation Science
NASA Astrophysics Data System (ADS)
Bevelacqua, Joseph John
2010-05-01
Introductory physics courses present the basic concepts of radioactivity and an overview of nuclear physics that emphasizes the basic decay relationship and the various types of emitted radiation. Although this presentation provides insight into radiological science, it often fails to interest students to explore these concepts in a more rigorous manner. One reason for limited student interest is the failure to link the discussion to topics of current interest. The author has found that presenting this material with a link to radiological dispersion devices (RDDs), or dirty bombs, and their associated health effects provides added motivation for students. The events of Sept. 11, 2001, and periodic media focus on RDDs heighten student interest from both a scientific curiosity as well as a personal protection perspective. This article presents a framework for a more interesting discussion of the basics of radiation science and their associated health effects. The presentation can be integrated with existing radioactivity lectures or added as a supplementary or enrichment activity.
Interference of medical contrast media on laboratory testing.
Lippi, Giuseppe; Daves, Massimo; Mattiuzzi, Camilla
2014-01-01
The use of contrast media such as organic iodine molecules and gadolinium contrast agents is commonplace in diagnostic imaging. Although there is widespread perception that side effects and drug interactions may be the leading problems caused by these compounds, various degrees of interference with some laboratory tests have been clearly demonstrated. Overall, the described interference for iodinate contrast media include inappropriate gel barrier formation in blood tubes, the appearance of abnormal peaks in capillary zone electrophoresis of serum proteins, and a positive bias in assessment of cardiac troponin I with one immunoassay. The interference for gadolinium contrast agents include negative bias in calcium assessment with ortho-cresolphthalein colorimetric assays and occasional positive bias using some Arsenazo reagents, negative bias in measurement of angiotensin converting enzyme (ACE) and zinc (colorimetric assay), as well as positive bias in creatinine (Jaffe reaction), total iron binding capacity (TIBC, ferrozine method), magnesium (calmagite reagent) and selenium (mass spectrometry) measurement. Interference has also been reported in assessment of serum indices, pulse oximetry and methaemoglobin in samples of patients receiving Patent Blue V. Under several circumstances the interference was absent from manufacturer-supplied information and limited to certain type of reagents and/or analytes, so that local verification may be advisable to establish whether or not the test in use may be biased. Since the elimination half-life of these compounds is typically lower than 2 h, blood collection after this period may be a safer alternative in patients who have received contrast media for diagnostic purposes.
Interference of medical contrast media on laboratory testing
Lippi, Giuseppe; Daves, Massimo; Mattiuzzi, Camilla
2014-01-01
The use of contrast media such as organic iodine molecules and gadolinium contrast agents is commonplace in diagnostic imaging. Although there is widespread perception that side effects and drug interactions may be the leading problems caused by these compounds, various degrees of interference with some laboratory tests have been clearly demonstrated. Overall, the described interference for iodinate contrast media include inappropriate gel barrier formation in blood tubes, the appearance of abnormal peaks in capillary zone electrophoresis of serum proteins, and a positive bias in assessment of cardiac troponin I with one immunoassay. The interference for gadolinium contrast agents include negative bias in calcium assessment with ortho-cresolphthalein colorimetric assays and occasional positive bias using some Arsenazo reagents, negative bias in measurement of angiotensin converting enzyme (ACE) and zinc (colorimetric assay), as well as positive bias in creatinine (Jaffe reaction), total iron binding capacity (TIBC, ferrozine method), magnesium (calmagite reagent) and selenium (mass spectrometry) measurement. Interference has also been reported in assessment of serum indices, pulse oximetry and methaemoglobin in samples of patients receiving Patent Blue V. Under several circumstances the interference was absent from manufacturer-supplied information and limited to certain type of reagents and/or analytes, so that local verification may be advisable to establish whether or not the test in use may be biased. Since the elimination half-life of these compounds is typically lower than 2 h, blood collection after this period may be a safer alternative in patients who have received contrast media for diagnostic purposes. PMID:24627717
Imaging professionals' views of social media and its implications.
Bagley, Jennifer E; DiGiacinto, Dora D; Hargraves, Kensi
2014-01-01
To help radiation sciences students and professionals understand the implications of and best practices for personal postings on social media Web sites. The authors conducted a survey to capture radiologic science professionals' opinions regarding trends related to using social media for employment, as well as for their personal use. The majority of imaging professionals are mindful of their privacy settings and believe their activity on social media sites reflects on them professionally. Participants in this study noted they maintain high privacy settings. In spite of this, both supervisors and nonsupervisors in this study held opinions about the use of social media in employment decisions that are inconsistent with what can occur in the workplace. Survey respondents did not believe there should be employment sanctions for behaviors that routinely are sanctioned in the workplace. An important message that has emerged from this research is that employees should not only adhere to the strictest privacy settings on their personal social media sites, but they also should be judicious in what they choose to share, with the understanding that nothing posted online is truly private. Supervisors and nonsupervisors should become familiar with their institutional policies regarding the use of social media in the workplace, and supervisors specifically should ensure that they follow institutional policy regarding the use of social media in employment decisions.
Prospects of molybdenum and rhenium octahedral cluster complexes as X-ray contrast agents.
Krasilnikova, Anna A; Shestopalov, Michael A; Brylev, Konstantin A; Kirilova, Irina A; Khripko, Olga P; Zubareva, Kristina E; Khripko, Yuri I; Podorognaya, Valentina T; Shestopalova, Lidiya V; Fedorov, Vladimir E; Mironov, Yuri V
2015-03-01
Investigation of new X-ray contrast media for radiography is an important field of science since discovering of X-rays in 1895. Despite the wide diversity of available X-ray contrast media the toxicity, especially nephrotoxicity, is still a big problem to be solved. The octahedral metal-cluster complexes of the general formula [{M6Q8}L6] can be considered as quite promising candidates for the role of new radiocontrast media due to the high local concentration of heavy elements, high tuning ability of ligand environment and low toxicity. To exemplify this, the X-ray computed tomography experiments for the first time were carried out on some octahedral cluster complexes of molybdenum and rhenium. Based on the obtained data it was proposed to investigate the toxicological proprieties of cluster complex Na2H8[{Re6Se8}(P(CH2CH2CONH2)(CH2CH2COO)2)6]. Observed low cytotoxic and acute toxic effects along with rapid renal excretion of the cluster complex evidence its perspective as an X-ray contrast media for radiography. Copyright © 2014 Elsevier Inc. All rights reserved.
Active imaging with the aids of polarization retrieve in turbid media system
NASA Astrophysics Data System (ADS)
Tao, Qiangqiang; Sun, Yongxuan; Shen, Fei; Xu, Qiang; Gao, Jun; Guo, Zhongyi
2016-01-01
We propose a novel active imaging based on the polarization retrieve (PR) method in turbid media system. In our simulations, the Monte Carlo (MC) algorithm has been used to investigate the scattering process between the incident photons and the scattering particles, and the visually concordant object but with different polarization characteristics in different regions, has been selected as the original target that is placed in the turbid media. Under linearly and circularly polarized illuminations, the simulation results demonstrate that the corresponding polarization properties can provide additional information for the imaging, and the contrast of the polarization image can also be enhanced greatly compared to the simplex intensity image in the turbid media. Besides, the polarization image adjusted by the PR method can further enhance the visibility and contrast. In addition, by PR imaging method, with the increasing particles' size in Mie's scale, the visibility can be enhanced, because of the increased forward scattering effect. In general, in the same circumstance, the circular polarization images can offer a better contrast and visibility than that of linear ones. The results indicate that the PR imaging method is more applicable to the scattering media system with relatively larger particles such as aerosols, heavy fog, cumulus, and seawater, as well as to biological tissues and blood media.
Lee, Young Han
2018-04-04
The purposes of this study are to evaluate the feasibility of protocol determination with a convolutional neural networks (CNN) classifier based on short-text classification and to evaluate the agreements by comparing protocols determined by CNN with those determined by musculoskeletal radiologists. Following institutional review board approval, the database of a hospital information system (HIS) was queried for lists of MRI examinations, referring department, patient age, and patient gender. These were exported to a local workstation for analyses: 5258 and 1018 consecutive musculoskeletal MRI examinations were used for the training and test datasets, respectively. The subjects for pre-processing were routine or tumor protocols and the contents were word combinations of the referring department, region, contrast media (or not), gender, and age. The CNN Embedded vector classifier was used with Word2Vec Google news vectors. The test set was tested with each classification model and results were output as routine or tumor protocols. The CNN determinations were evaluated using the receiver operating characteristic (ROC) curves. The accuracies were evaluated by a radiologist-confirmed protocol as the reference protocols. The optimal cut-off values for protocol determination between routine protocols and tumor protocols was 0.5067 with a sensitivity of 92.10%, a specificity of 95.76%, and an area under curve (AUC) of 0.977. The overall accuracy was 94.2% for the ConvNet model. All MRI protocols were correct in the pelvic bone, upper arm, wrist, and lower leg MRIs. Deep-learning-based convolutional neural networks were clinically utilized to determine musculoskeletal MRI protocols. CNN-based text learning and applications could be extended to other radiologic tasks besides image interpretations, improving the work performance of the radiologist.
Prevention of Contrast-Induced Nephropathy through a Knowledge of Its Pathogenesis and Risk Factors
Faga, Teresa; Pisani, Antonio; Russo, Domenico; Michael, Ashour
2014-01-01
Contrast-induced nephropathy (CIN) is an iatrogenic acute renal failure (ARF) occurring after the intravascular injection of iodinated radiographic contrast media. During the past several years, in many patients undergoing computed tomography, iodinated contrast media have not been used for the fear of ARF, thereby compromising the diagnostic procedure. But recent studies have demonstrated that CIN is rarely occurring in patients with normal renal function and that preexisting chronic renal failure and/or diabetes mellitus represent(s) predisposing condition(s) for its occurrence. After the description of CIN and its epidemiology and pathophysiology, underlying the important role played by dehydration and salt depletion, precautions for prevention of CIN are listed, suggested, and discussed. Maximum priority has to be given to adequate hydration and volume expansion prior to radiographic procedures. Other important precautions include the need for monitoring renal function before, during, and after contrast media injection, discontinuation of potentially nephrotoxic drugs, use of either iodixanol or iopamidol at the lowest dosage possible, and administration of antioxidants. A long list of references is provided that will enable readers a deep evaluation of the topic. PMID:25525625
Camera, Luigi; Romano, Federica; Liccardo, Immacolata; Liuzzi, Raffaele; Imbriaco, Massimo; Mainenti, Pier Paolo; Pizzuti, Laura Micol; Segreto, Sabrina; Maurea, Simone; Brunetti, Arturo
2015-11-01
As both contrast and radiation dose affect the quality of CT images, a constant image quality in abdominal contrast-enhanced multidetector computed tomography (CE-MDCT) could be obtained balancing radiation and contrast media dose according to the age of the patients. Seventy-two (38 Men; 34 women; aged 20-83 years) patients underwent a single-pass abdominal CE-MDCT. Patients were divided into three different age groups: A (20-44 years); B (45-65 years); and C (>65 years). For each group, a different noise index (NI) and contrast media dose (370 mgI/mL) was selected as follows: A (NI, 15; 2.5 mL/kg), B (NI, 12.5; 2 mL/kg), and C (NI, 10; 1.5 mL/kg). Radiation exposure was reported as dose-length product (DLP) in mGy × cm. For quantitative analysis, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both the liver (L) and the abdominal aorta (A). Statistical analysis was performed with a one-way analysis of variance. Standard imaging criteria were used for qualitative analysis. Although peak hepatic enhancement was 152 ± 16, 128 ± 12, and 101 ± 14 Hounsfield units (P < .001) for groups A, B, and C, respectively, no significant differences were observed in the corresponding SNRL with 9.2 ± 1.4, 9.1 ± 1.2, and 9.2 ± 3. Radiation (mGy × cm) and contrast media dose (mL) administered were 476 ± 147 and 155 ± 27 for group A, 926 ± 291 and 130 ± 16 for group B, and 1981 ± 451 and 106 ± 15 for group C, respectively (P < .001). None of the studies was graded as poor or inadequate by both readers, and the prevalence-adjusted bias-adjusted kappa ranged between 0.48 and 0.93 for all but one criteria. A constant image quality in CE-MDCT can be obtained balancing radiation and contrast media dose administered to patients of different age. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yusob, Diana; Zukhi, Jihan; Aziz Tajuddin, Abd; Zainon, Rafidah
2017-05-01
The aim of this study was to evaluate the efficacy of metal artefact reduction using contrasts media in Computed Tomography (CT) imaging. A water-based abdomen phantom of diameter 32 cm (adult body size) was fabricated using polymethyl methacrylate (PMMA) material. Three different contrast agents (iodine, barium and gadolinium) were filled in small PMMA tubes and placed inside a water-based PMMA adult abdomen phantom. The orthopedic metal screw was placed in each small PMMA tube separately. These two types of orthopedic metal screw (stainless steel and titanium alloy) were scanned separately. The orthopedic metal crews were scanned with single-energy CT at 120 kV and dual-energy CT at fast kV-switching between 80 kV and 140 kV. The scan modes were set automatically using the current modulation care4Dose setting and the scans were set at different pitch and slice thickness. The use of the contrast media technique on orthopedic metal screws were optimised by using pitch = 0.60 mm, and slice thickness = 5.0 mm. The use contrast media can reduce the metal streaking artefacts on CT image, enhance the CT images surrounding the implants, and it has potential use in improving diagnostic performance in patients with severe metallic artefacts. These results are valuable for imaging protocol optimisation in clinical applications.
[Imaging anatomy of cranial nerves].
Hermier, M; Leal, P R L; Salaris, S F; Froment, J-C; Sindou, M
2009-04-01
Knowledge of the anatomy of the cranial nerves is mandatory for optimal radiological exploration and interpretation of the images in normal and pathological conditions. CT is the method of choice for the study of the skull base and its foramina. MRI explores the cranial nerves and their vascular relationships precisely. Because of their small size, it is essential to obtain images with high spatial resolution. The MRI sequences optimize contrast between nerves and surrounding structures (cerebrospinal fluid, fat, bone structures and vessels). This chapter discusses the radiological anatomy of the cranial nerves.
NASA Technical Reports Server (NTRS)
1986-01-01
Mallinckrodt Institute of Radiology (MIR) is using a digital image processing system which employs NASA-developed technology. MIR's computer system is the largest radiology system in the world. It is used in diagnostic imaging. Blood vessels are injected with x-ray dye, and the images which are produced indicate whether arteries are hardened or blocked. A computer program developed by Jet Propulsion Laboratory known as Mini-VICAR/IBIS was supplied to MIR by COSMIC. The program provides the basis for developing the computer imaging routines for data processing, contrast enhancement and picture display.
Socher, M; Kuntz, J; Sawall, S; Bartling, S; Kachelrieß, M
2014-04-01
Cardiac perfusion studies using computed tomography are a common tool in clinical practice. Recent technical advances and the availability of dedicated small animal scanners allow the transfer of these techniques to the preclinical sector in general and to mouse models of cardiac diseases in particular. This necessitates new requirements for contrast injection techniques as a rapid transport of contrast media from the intravenous access to the animal heart. Clinical contrast agents containing high iodine concentrations are used within small animal studies although they exhibit a high viscosity which might limit their transport within the vasculature. The authors provide a comparison of the transport of contrast media following an injection into the lateral tail vein and an injection into the retrobulbar sinus and discuss the anatomy involved. The temporal evolution of a contrast bolus and its in vivo distribution is visualized. It is demonstrated that injecting contrast agents into the lateral tail vein of mice results in a retrograde blood flow to the liver veins and therefore does not deliver a detectable contrast bolus to the heart, and thus it cannot be used for cardiac perfusion studies. By contrast, boli injected into the retrobulbar sinus are rapidly transported to the heart and provide ventricular contrast enabling perfusion studies similar to those in human patients. The results demonstrate that an injection into the retrobulbar sinus is superior to an injection into the lateral tail vein for the delivery of contrast boli to the animal heart, while all drawbacks of an injection into the lateral tail vein are overcome.
Ng, Kwan-Hoong; Lean, Mei-Li
2012-09-01
The potential of social media has expanded far beyond the initial function of social communication among a network of friends. It has become an increasingly important tool in risk communication to allow the dissemination of timely and accurate information to global citizens to make more informed choices regarding a particular crisis. The Fukushima nuclear crisis is an example where the potential of social media was not fully tapped. This caused undue stress and distrust of authorities. While the use of social media in this crisis could have altered significantly the level of trust in authorities and others, two additional points should be considered. One point is the use of plain language versus scientific language in order to reach a wider audience. The other is an urgent need to improve public information especially in the event of a nuclear emergency and to enhance educational efforts and action by improving radiological protection communication from regulatory bodies and international agencies. These are points that also play a large role in the use of social media.
Realism and Romance: The Study of Media Effects.
ERIC Educational Resources Information Center
Tuchman, Gaye
1993-01-01
Compares and contrasts two studies representing diametrical approaches (Romanticism versus Realism) toward the issue of agency and media effects: P. Willis's "Common Culture" and W. A. Gamson's "Talking Politics." Argues that both studies find that people make their own uses of media. (SR)
Acceptability of oral iodinated contrast media: a head-to-head comparison of four media.
Pollentine, A; Ngan-Soo, E; McCoubrie, P
2013-05-01
To assess the palatability of iodinated oral contrast media commonly used in abdominopelvic CT and CT colonography (CTC). 80 volunteers assessed the palatability of a 20-ml sample of a standard 30 mg ml(-1) dilution of Omnipaque® (iohexol; GE Healthcare, Cork, Ireland), Telebrix® (meglumine ioxithalamate; Guerbet, Aulnay-sous-Bois, France), Gastromiro® (iopamidol; Bracco, High Wycombe, UK) and Gastrografin® (sodium diatrizoate and meglumine diatrizoate; Bayer, Newbury, UK) in a computer-generated random order. Gastrografin is rated significantly less palatable than the remaining media (p<0.005). Omnipaque and Telebrix are significantly more palatable than Gastromiro. No difference existed between Omnipaque and Telebrix. 39% of participants would refuse to consume the quantities of Gastrografin required for a CTC examination compared with Telebrix (7%) and Omnipaque (9%) (p<0.05). Omnipaque and Telebrix are significantly more palatable than both Gastromiro and Gastrografin, with participants more willing to ingest them in larger quantities as well as being less expensive. Omnipaque and Telebrix are significantly more palatable iodinated oral contrast media than both Gastromiro and Gastrografin, which has potential implications in compliance with both abdominopelvic CT and CTC.
Acceptability of oral iodinated contrast media: a head-to-head comparison of four media
Ngan-Soo, E; McCoubrie, P
2013-01-01
Objective: To assess the palatability of iodinated oral contrast media commonly used in abdominopelvic CT and CT colonography (CTC). Methods: 80 volunteers assessed the palatability of a 20-ml sample of a standard 30 mg ml−1 dilution of Omnipaque® (iohexol; GE Healthcare, Cork, Ireland), Telebrix® (meglumine ioxithalamate; Guerbet, Aulnay-sous-Bois, France), Gastromiro® (iopamidol; Bracco, High Wycombe, UK) and Gastrografin® (sodium diatrizoate and meglumine diatrizoate; Bayer, Newbury, UK) in a computer-generated random order. Results: Gastrografin is rated significantly less palatable than the remaining media (p<0.005). Omnipaque and Telebrix are significantly more palatable than Gastromiro. No difference existed between Omnipaque and Telebrix. 39% of participants would refuse to consume the quantities of Gastrografin required for a CTC examination compared with Telebrix (7%) and Omnipaque (9%) (p<0.05). Conclusion: Omnipaque and Telebrix are significantly more palatable than both Gastromiro and Gastrografin, with participants more willing to ingest them in larger quantities as well as being less expensive. Advances in knowledge: Omnipaque and Telebrix are significantly more palatable iodinated oral contrast media than both Gastromiro and Gastrografin, which has potential implications in compliance with both abdominopelvic CT and CTC. PMID:23564884
Musolino, Stephen V; Harper, Frederick T
2006-04-01
Strategies and decisions to protect emergency responders, the public, and critical infrastructure against the effects of a radiological dispersal device detonated outdoors must be made in the planning stage, not in the early period just after an attack. This contrasts with planning for small-scale types of radiological or nuclear emergencies, or for a large-scale nuclear-power-type accident that evolves over many hours or days before radioactivity is released to the environment, such that its effects can be prospectively modeled and analyzed. By the time it is known an attack has occurred, most likely there will have been casualties, all the radioactive material will have been released, plume growth will be progressing, and there will be no time left for evaluating possible countermeasures. This paper offers guidance to planners, first responders, and senior decision makers to assist them in developing strategies for protective actions and operational procedures for the first 48 hours after an explosive radiological dispersal device has been detonated.
Abdulkadir, Kocer; Buket, Sanlisoy; Dilek, Agircan; Munevver, Okay; Ayse, Aralasmak
2015-04-01
Otitis media is a well-known condition and its infra-temporal and intracranial complications are extremely rare because of the widespread usage of antibiotic treatment. We report a case of 63-year-old female with complaints of right-sided facial pain and diplopia. She had a history of acute otitis media before 4 months of admission to our neurology unit. Neurological examination showed that total ophthalmoplegia with ptosis, mydriasis, decreased vision and loss of pupil reflex on the right side. In addition, there was involvement of 5th and 7th cranial nerves. Neurological and radiological follow-up examinations demonstrated Jacod's Syndrome with unusual facial nerve damage and infection in aetiology. Sinusitis is the most common aetiology, but there are a few cases reported Jacod's Syndrome originating from otitis media.
CT contrast extravasation in the upper extremity: strategies for management.
Sbitany, Hani; Koltz, Peter F; Mays, Chester; Girotto, John A; Langstein, Howard N
2010-01-01
Extravasation of CT scan contrast media into upper extremity subcutaneous tissue is a relatively frequent complication of injection. Potential sequelae of extravasation include compartment syndrome, skin sloughing, and necrosis. Many institutions institute protocols requiring inpatient plastic surgery consultations immediately following extravasation injury to the upper extremity. We hypothesize that conversion to non-ionic contrast media for contrast CT studies has greatly reduced the incidence of severe extravasation injuries, and may alleviate the need for routine hand surgery consultations. Records from 102 consecutive CT contrast media extravasation injuries were identified. Data acquired from a single institution included type and amount of contrast extravasated, anatomic location, post-procedural clinical symptoms, whether consult was obtained, and final recommendations and outcome. In 102 consecutive cases, immediate surgical therapy was necessary in 0. Non-ionic medium was used in 94% of these cases, and ionic dye was used in 6%. Extravasation of less than 100 cc occurred in 90%, and only 10% were greater. Plastic surgery consultation was immediately obtained in 42% of cases. Factors prompting consultation included extravasation >30 cc, and the presence of erythema or induration. Trends for consultation remained without discernable pattern when patients were stratified by age, amount of extravasate, or anatomic location. Conservative management was recommended in all cases. This included elevation of the extremity, frequent pulse and sensation exams, local message, and temporary splinting. There were no secondary complications requiring surgical intervention. Extravasation of non-ionic CT contrast media appears to be innocuous and can be treated with conservative therapy. Plastic surgery consultation should be obtained when there are obvious signs of skin and soft tissue compromise or symptoms of compartment syndrome. Copyright 2010 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Activist Media in Native AIDS Organizing: Theorizing the Colonial Conditions of AIDS
ERIC Educational Resources Information Center
Morgensen, Scott
2008-01-01
In this article, the author examines how activist media by Native AIDS organizers promoted anticolonial analyses of AIDS, gender, and sexuality as a contribution to scholarship on Native responses to AIDS. His discussion centers on the organizers who created media as authorities on and in their media. In contrast to recent accounts that popularize…
Gadolinium-based magnetic resonance imaging contrast agents in interventional radiology.
Atar, Eli
2004-07-01
Gadolinium-based agents are widely used in magnetic resonance imaging as contrast agents. These agents are radio-opaque enough for diagnostic imaging of the vascular tree by using digitally subtracted images as well as for imaging of the biliary system and the urinary tract. The recommended doses for gadolinium do not impair renal function or cause adverse reactions in patients with iodine sensitivity; thus patients with such conditions can safely undergo diagnostic angiography, either by MRI angiography or by catheterization using gadolinium as contrast agent, for diagnostic and therapeutic purposes.
Sarwani, Nabeel; Tappouni, Rafel; Flemming, Donald
2012-08-01
Simulation laboratories use realistic clinical scenarios to train physicians in a controlled environment, especially in potentially life-threatening complications that require prompt management. The objective of our study was to develop a comprehensive program using the simulation laboratory to train radiology residents in the management of acute radiologic emergencies. All radiology residents attended a dedicated simulation laboratory course lasting 3 hours, divided over two sessions. Training included basic patient management skills, management of a tension pneumothorax, massive hemorrhage, and contrast agent reactions. Participants were presented with 20 multiple-choice questions before and after the course. Pre- and posttest results were analyzed, and the McNemar test was used to compare correct responses by individual question. Twenty-six radiology residents attended the class. The average pre- and posttest scores and the average difference between the scores for all residents were 13.8, 17.1, and 3.3, respectively (p < 0.0001). Incorrect answers on the pretest examination that were subsequently answered correctly concerned administration of epinephrine for severe reactions, management of a tension pneumothorax, oxygen therapy, ECG placement, cardiopulmonary resuscitation technique, and where to stand during a code situation. Persistent incorrect answers concerned vasovagal reactions and emergency telephone numbers at an off-site imaging center. Simulation laboratories can be used to teach crisis management and crisis resource management for radiology residents and should be part of the education toolbox. Defined objectives lead to a comprehensive course dealing with the management of acute radiologic emergencies. Such programs can improve the role of radiologists as members of the health care team.
Wobser, Hella; Gunesch, Agnetha; Klebl, Frank
2017-01-13
Patients with biliary obstruction are at high risk to develop septic complications after endoscopic retrograde cholangiography (ERC). We evaluated the benefits of local application of antimicrobial agents into ERC contrast media in preventing post-ERC infectious complications in a high-risk study population. Patients undergoing ERC at our tertiary referral center were retrospectively included. Addition of vancomycin, gentamicin and fluconazol into ERC contrast media was evaluated in a case-control design. Outcomes comprised infectious complications within 3 days after ERC. In total, 84 ERC cases were analyzed. Primarily indications for ERC were sclerosing cholangitis (75%) and malignant stenosis (9.5%). Microbial testing of collected bile fluid in the treatment group was positive in 91.4%. Detected organisms were sensitive to the administered antimicrobials in 93%. The use of antimicrobials in contrast media was associated with a significant decrease in post-ERC infectious complications compared to non-use (14.3% vs. 33.3%; odds ratio [OR]: 0.33, 95% confidence interval [CI]: 0.114-0.978). After adjusting for the variables acute cholangitis prior to ERC and incomplete biliary drainage, the beneficial effect of intraductal antibiotic prophylaxis was even more evident (OR = 0.153; 95% CI: 0.039-0.598, p = 0.007). Patients profiting most obviously from intraductal antimicrobials were those with secondary sclerosing cholangitis. Local application of a combination of antibiotic and antimycotic agents to ERC contrast media efficiently reduced post-ERC infectious events in patients with biliary obstruction. This is the first study that evaluates ERC-related infectious complications in patients with secondary sclerosing cholangitis. Our first clinical results should now be prospectively evaluated in a larger patient cohort to improve the safety of ERC, especially in patients with secondary sclerosing cholangitis.
Jung, Seung Chai; Cho, Jeong Yeon
2011-01-01
Objective To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. Materials and Methods A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. Results The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). Conclusion The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan. PMID:22043154
Arterial spin labeling blood flow magnetic resonance imaging for evaluation of renal injury.
Liu, Yupin P; Song, Rui; Liang, Chang hong; Chen, Xin; Liu, Bo
2012-08-15
A multitude of evidence suggests that iodinated contrast material causes nephrotoxicity; however, there have been no previous studies that use arterial spin labeling (ASL) blood flow functional magnetic resonance imaging (fMRI) to investigate the alterations in effective renal plasma flow between normointensive and hypertensive rats following injection of contrast media. We hypothesized that FAIR-SSFSE arterial spin labeling MRI may enable noninvasive and quantitative assessment of regional renal blood flow abnormalities and correlate with disease severity as assessed by histological methods. Renal blood flow (RBF) values of the cortex and medulla of rat kidneys were obtained from ASL images postprocessed at ADW4.3 workstation 0.3, 24, 48, and 72 h before and after injection of iodinated contrast media (6 ml/kg). The H&E method for morphometric measurements was used to confirm the MRI findings. The RBF values of the outer medulla were lower than those of the cortex and the inner medulla as reported previously. Iodinated contrast media treatment resulted in decreases in RBF in the outer medulla and cortex in spontaneously hypertensive rats (SHR), but only in the outer medulla in normotensive rats. The iodinated contrast agent significantly decreased the RBF value in the outer medulla and the cortex in SHR compared with normotensive rats after injection of the iodinated contrast media. Histological observations of kidney morphology were also consistent with ASL perfusion changes. These results demonstrate that the RBF value can reflect changes of renal perfusion in the cortex and medulla. ASL-MRI is a feasible and accurate method for evaluating nephrotoxic drugs-induced kidney damage.
Kim, Young-sun; Rhim, Hyunchul; Lim, Hyo Keun; Choi, Dongil; Lee, Min Woo; Park, Min Jung
2011-01-01
As the clinical role of radiofrequency ablation (RFA) of the liver grows, the importance of radiologic imaging after liver RFA to depict the diversity of post-RFA manifestations is also increasing. Because RFA induces coagulation necrosis of the hepatic parenchyma, cross-sectional imaging studies, in principle, demonstrate an area with a defect in contrast enhancement. However, for various reasons, such as the occurrence of a complication, the RFA zone may demonstrate different patterns or be accompanied by other abnormalities. In this investigation, a large number of imaging studies performed after more than 4000 procedures of liver RFA during the past 10-year period were reviewed, and various radiologic manifestations of the RFA zone were compiled. Herein, the basic principles of RFA, as well as the histopathologic features of coagulation necrosis of the liver, are catalogued to provide a more complete understanding of such changes. Through this review, the reader will become more familiar with the usual and unusual radiologic findings of coagulation necrosis induced by RFA in the liver. This increased familiarity will not only facilitate the daily practice of radiology but also deepen understanding of the therapeutic modality of RFA. © RSNA, 2011.
Ambient lighting: setting international standards for the viewing of softcopy chest images
NASA Astrophysics Data System (ADS)
McEntee, Mark F.; Ryan, John; Evanoff, Micheal G.; Keeling, Aoife; Chakraborty, Dev; Manning, David; Brennan, Patrick C.
2007-03-01
Clinical radiological judgments are increasingly being made on softcopy LCD monitors. These monitors are found throughout the hospital environment in radiological reading rooms, outpatient clinics and wards. This means that ambient lighting where clinical judgments from images are made can vary widely. Inappropriate ambient lighting has several deleterious effects: monitor reflections reduce contrast; veiling glare adds brightness; dynamic range and detectability of low contrast objects is limited. Radiological images displayed on LCDs are more sensitive to the impact of inappropriate ambient lighting and with these devices problems described above are often more evident. The current work aims to provide data on optimum ambient lighting, based on lesions within chest images. The data provided may be used for the establishment of workable ambient lighting standards. Ambient lighting at 30cms from the monitor was set at 480 Lux (office lighting) 100 Lux (WHO recommendations), 40 Lux and <10 Lux. All monitors were calibrated to DICOM part 14 GSDF. Sixty radiologists were presented with 30 chest images, 15 images having simulated nodular lesions of varying subtlety and size. Lesions were positioned in accordance with typical clinical presentation and were validated radiologically. Each image was presented for 30 seconds and viewers were asked to identify and score any visualized lesion from 1-4 to indicate confidence level of detection. At the end of the session, sensitivity and specificity were calculated. Analysis of the data suggests that visualization of chest lesions is affected by inappropriate lighting with chest radiologists demonstrating greater ambient lighting dependency. JAFROC analyses are currently being performed.
[Gastrocolocutaneous fistula: an uncommon complication of percutaneous endoscopic gastrostomy].
Ruiz Ruiz, J M; Rando Muñoz, J F; Salvá Villar, P; Lamarca Hurtado, J C; Sánchez Molinero, Ma D; Sanjurgo Molezun, E; Vázquez Pedreño, L; Manteca González, R
2012-01-01
Endoscopic percutaneous gastrostomy is a safe technique although with potential complications before which the clinician has to be on alert in order to early detect them even after a long period of normal functioning. Most of them represent minor problems. Gastrocolocutaneous fistula is a rare but severe complication favored by some risk factors such as previous post-surgical adherences, deformities of the spine, or excessive gastric inflation at the time of performing the technique. We present the case of a patient with PEG with this complication that occurred after the first tube replacement. Our goal was in two senses: on the one hand, to analyze the preventive aspects and basic guidelines for a safe PEG placement to minimize the risks; on the other hand, to alert on the possible presence of this entity to prevent a progressive nutritional impairment. This complication ought to be included in the differential diagnosis of the diarrhea syndrome in the patient carrying a PEG. The diagnostic techniques of choice are radiologic tests such as CT scan and contrast media administration through the tube. Surgical therapy should be reserved to patients with acute peritonitis in order to perform a new gastrostomy.
Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET)/MRI for Lung Cancer Staging.
Ohno, Yoshiharu; Koyama, Hisanobu; Lee, Ho Yun; Yoshikawa, Takeshi; Sugimura, Kazuro
2016-07-01
Tumor, lymph node, and metastasis (TNM) classification of lung cancer is typically performed with the TNM staging system, as recommended by the Union Internationale Contre le Cancer (UICC), the American Joint Committee on Cancer (AJCC), and the International Association for the Study of Lung Cancer (IASLC). Radiologic examinations for TNM staging of lung cancer patients include computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography with 2-[fluorine-18] fluoro-2-deoxy-D-glucose (FDG-PET), and FDG-PET combined with CT (FDG-PET/CT) and are used for pretherapeutic assessments. Recent technical advances in MR systems, application of fast and parallel imaging and/or introduction of new MR techniques, and utilization of contrast media have markedly improved the diagnostic utility of MRI in this setting. In addition, FDG-PET can be combined or fused with MRI (PET/MRI) for clinical practice. This review article will focus on these recent advances in MRI as well as on PET/MRI for lung cancer staging, in addition to a discussion of their potential and limitations for routine clinical practice in comparison with other modalities such as CT, FDG-PET, and PET/CT.
Management of delayed major visceral arterial bleeding after pancreatic surgery
Schäfer, Markus; Heinrich, Stefan; Pfammatter, Thomas; Clavien, Pierre-Alain
2011-01-01
Objectives Postoperative bleeding represents a life-threatening complication after pancreatic surgery. Recent developments in interventional radiology have challenged the role of surgery in bleeding control. This study aimed to assess the management of major haemorrhagic complications after pancreatic surgery at a tertiary referral centre. Methods Between August 1998 and June 2009, 18 patients with major bleeding after pancreatic surgery were admitted to the University Hospital of Zurich, Zurich, Switzerland. We retrospectively analysed their medical charts, focusing on diagnosis, therapy and outcome. Results Major arterial bleeding occurred after a median postoperative interval of 21.5 days (range: 9–259 days). Seventeen patients demonstrated various symptoms, such as repeated upper gastrointestinal bleeding or haemorrhagic shock. Diagnosis was usually made by contrast-enhanced computed tomography (CT). Leakage of the pancreaticojejunostomy caused the formation of a pseudoaneurysm in 78% of patients. Haemostasis was achieved in 10 patients by interventional radiology. Two patients died of massive re-bleeding. Six patients underwent primary emergency surgery, which five did not survive. Conclusions Delayed bleeding after pancreatic surgery is suspicious for a pseudoaneurysm. Contrast-enhanced CT followed by early angiography provides accurate diagnosis and treatment. Interventional radiological treatment should be preferred over primary surgery because it is currently the most life-saving approach. PMID:21241431
Anaphylactoid reactions to the nonvascular administration of water-soluble iodinated contrast media.
Davis, Peter L
2015-06-01
Anaphylactoidlike reactions occur during the nonvascular administration of iodinated contrast media. Many of these reactions have been severe. These reactions have occurred with many procedures, including gastrointestinal imaging, cystography, sialography, and hysterosalpingography. This article reviews reports of these reactions. It also reviews what the literature recommends concerning how to deal with individuals undergoing these procedures who are at a higher risk for anaphylactoidlike reactions.
Kim, Sue Min; Cook, Kyung Hoon; Lee, Il Jae; Park, Dong Ha; Park, Myong Chul
2017-04-01
In our hospital, an adverse event reporting system was initiated that alerts the plastic surgery department immediately after suspecting contrast media extravasation injury. This system is particularly important for a large volume of extravasation during power injector use. Between March 2011 and May 2015, a retrospective chart review was performed on all patients experiencing contrast media extravasation while being treated at our hospital. Immediate treatment by squeezing with multiple slit incisions was conducted for a portion of these patients. Eighty cases of extravasation were reported from approximately 218 000 computed tomography scans. The expected extravasation volume was larger than 50 ml, or severe pressure was felt on the affected limb in 23 patients. They were treated with multiple slit incisions followed by squeezing. Oedema of the affected limb disappeared after 1-2 hours after treatment, and the skin incisions healed within a week. We propose a set of guidelines for the initial management of contrast media extravasation injuries for a timely intervention. For large-volume extravasation cases, immediate management with multiple slit incisions is safe and effective in reducing the swelling quickly, preventing patient discomfort and decreasing skin and soft tissue problems. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Patterson, Mark S; Dirksen, Maurits T; Ijsselmuiden, Alexander J; Amoroso, Giovanni; Slagboom, Ton; Laarman, Gerrit-Jan; Schultz, Carl; van Domburg, Ron T; Serruys, Patrick W; Kiemeneij, Ferdinand
2011-06-01
Aims Comparison of magnetic guidewire navigation in percutaneous coronary intervention (MPCI) vs. conventional percutaneous coronary intervention (CPCI) for the treatment of acute myocardial infarction. Methods and results We compared 65 sequential patients (mean age 61 ± 15 years) undergoing primary MPCI with those of 405 patients undergoing CPCI (mean age 61 ± 13 years). The major endpoint was contrast media use. Technical success and procedural outcomes were evaluated. Clinical demographics and angiographic characteristics of the two groups were similar, except for fewer patients with previous coronary artery bypass grafting (CABG) and hypertension in the CPCI group and fewer patients with diabetes in the MPCI group. The technical success rate was high in both the MPCI and CPCI groups (95.4 vs. 98%). There was significantly less contrast media usage in the MPCI compared with the CPCI group, median reduction of contrast media of 30 mL with an OR = 0.41 (0.21-0.81). Fluoroscopy times were significantly reduced for MPCI compared with CPCI, median reduction of 7.2 min with an OR = 0.42 (0.20-0.79). Conclusion This comparison indicates the feasibility and non-inferiority of magnetic navigation in performing primary PCI and suggests the possibility of reductions in contrast media use and fluoroscopy time compared with CPCI.
Demi, L; van Dongen, K W A; Verweij, M D
2011-03-01
Experimental data reveals that attenuation is an important phenomenon in medical ultrasound. Attenuation is particularly important for medical applications based on nonlinear acoustics, since higher harmonics experience higher attenuation than the fundamental. Here, a method is presented to accurately solve the wave equation for nonlinear acoustic media with spatially inhomogeneous attenuation. Losses are modeled by a spatially dependent compliance relaxation function, which is included in the Westervelt equation. Introduction of absorption in the form of a causal relaxation function automatically results in the appearance of dispersion. The appearance of inhomogeneities implies the presence of a spatially inhomogeneous contrast source in the presented full-wave method leading to inclusion of forward and backward scattering. The contrast source problem is solved iteratively using a Neumann scheme, similar to the iterative nonlinear contrast source (INCS) method. The presented method is directionally independent and capable of dealing with weakly to moderately nonlinear, large scale, three-dimensional wave fields occurring in diagnostic ultrasound. Convergence of the method has been investigated and results for homogeneous, lossy, linear media show full agreement with the exact results. Moreover, the performance of the method is demonstrated through simulations involving steered and unsteered beams in nonlinear media with spatially homogeneous and inhomogeneous attenuation. © 2011 Acoustical Society of America
Early renal dysfunction after contrast media administration despite prophylactic hydration.
Burchardt, Pawel; Guzik, Przemyslaw; Tabaczewski, Piotr; Synowiec, Tomasz; Bogdan, Monika; Faner, Paula; Chmielarz-Sobocińska, Anna; Palasz, Anna
2013-06-01
The actual incidence of renal dysfunction after contrast media administration seems to be underestimated, especially in the context of epidemiological data. There are only few data concerning the monitoring of impaired kidney function within a few hours after iodine contrast medium application. Hence, the purpose of this study is to observe the incidence of early renal function deterioration within 12-18 h after administration of iodine contrast media in patients scheduled for elective coronary angiography, who were intravenously and orally hydrated. In addition, the project aims to reclassify the contrast induced nephropathy phenomenon, by identification of early markers of renal dysfunction. Morphology, electrolytes, blood urea nitrogen (BUN), creatinine, low-density lipoprotein cholesterol, triglycerides, high-density lipoprotein, and total cholesterol levels were assessed with the use of typical laboratory techniques in 319 patients referred for coronary angiography. We demonstrated that early deterioration of renal function in patients 12-18 h after administration of contrast during imaging tests (even when appropriate prophylactic hydration was used), may occurred just as an increase (or no change) of serum creatinine level and BUN level and a decrease of creatinine clearance and glomerular filtration rate. Depending on the parameter, the phenomenon can be found in 13-28 % of all respondents. Early renal function impairment defined as above was almost 2 and 2.22 × 10(3) times (respectively) more frequently observed in our study than contrast induced nephropathy defined by current definitions.
Radiological Dispersal Device Primer: From A Terrorists Perspective
2008-02-15
third order ecnomic effects resulting from the lack of RDD insurance.69 This section discussed radiation impacts from a RDD attack. Based on...Command (NORTHCOM), to conduct warfighting within the homeland defense area of responsibility ( essentially the United States, Canada, and Mexico) and to...RDD attack.130 A prepared media will be essential to calm the public and facilitate first responder actions. Lastly, a robust and frequent
Image processing of angiograms: A pilot study
NASA Technical Reports Server (NTRS)
Larsen, L. E.; Evans, R. A.; Roehm, J. O., Jr.
1974-01-01
The technology transfer application this report describes is the result of a pilot study of image-processing methods applied to the image enhancement, coding, and analysis of arteriograms. Angiography is a subspecialty of radiology that employs the introduction of media with high X-ray absorption into arteries in order to study vessel pathology as well as to infer disease of the organs supplied by the vessel in question.
Bolognese, Leonardo; Falsini, Giovanni; Grotti, Simone; Limbruno, Ugo; Liistro, Francesco; Carrera, Arcangelo; Angioli, Paolo; Picchi, Andrea; Ducci, Kenneth; Pierli, Carlo
2010-03-01
Contrast-induced acute kidney injury (CI-AKI) is a complex syndrome of acute renal failure occurring after the administration of contrast media and contributing to prolonged hospital stay and mortality. The risk of CI-AKI is higher among patients undergoing primary percutaneous coronary interventions for acute myocardial infarction (AMI), but its clinical relevance in such setting has only been evaluated by small sample size single-center studies and retrospective or observational analyses. Furthermore, whereas high-osmolar contrast media was shown to have direct nephrotoxicity, the role of low-osmolar and iso-osmolar agents is still debated. The CONTRAST-AMI study is a prospective, multicenter, controlled, randomized, single-blind, parallel-group trial, designed to show the noninferiority of the effects of iopromide (low-osmolar) compared with iodixanol (iso-osmolar) contrast media on the incidence of CI-AKI and tissue-level perfusion in patients with AMI. All consecutive patients admitted to participating centers for ST-segment elevation AMI undergoing primary percutaneous coronary intervention will be enrolled. All patients will be treated with high-dose N-acetylcysteine (1200 mg intravenously during the procedure and 1200 mg orally two times daily for the next 48 h after percutaneous coronary intervention) and hydration according to a standardized protocol. The primary endpoint is the proportion of patients with a relative increase in serum creatinine (sCr) of at least 25% from baseline to 72 h after agent administration. The secondary endpoints are absolute and relative increases in sCr of at least 50%, thrombolysis in myocardial infarction (TIMI) perfusion grade, and major adverse cardiac events at 1, 6, and 12 months. The CONTRAST-AMI study will provide information on the effects of iodixanol and iopromide on the incidence of CI-AKI and tissue-level perfusion in patients with AMI.
Cleary, N; McNulty, J P; Foley, S J; Kelly, E
2017-11-01
Iodinated contrast extravasation is a serious complication associated with intravenous administration in radiology. Departmental protocols and the radiographer's approach on both prevention techniques and treatment will affect the prevalence of extravasation, and the eventual outcome for the patient when it does occur. To examine contrast extravasation protocols in place in Irish CT departments for alignment with European Society of Urogenital Radiology (ESUR) Guidelines (2014); to establish radiographer's opinions on contrast extravasation; and to examine radiographer adherence to protocols. Contrast extravasation protocols from a purposively selected sample of CT departments across Ireland (n = 6) were compared to ESUR guidelines, followed by an online survey of CT radiographers practicing in the participating centres. All participating CT departments (n = 5) had written protocols in place. High risk patients, such as elderly or unconscious, were identified in most protocols, however, children were mentioned in just one protocol and obese patients were not specified in any. The response rate of CT radiographers was 23% (n = 24). 58% (n = 14) of respondents indicated that contrast extravasation was more likely during CTA examinations. While high levels of confidence in managing extravasation were reported, suggested treatment approaches, and confidence in same, was more variable. Clinical workload in CT departments was also identified as a factor impacting on patient care and management. While contrast extravasation protocols were generally in line with ESUR Guidelines, high risk patients may not be getting sufficient attention. More radiographer awareness of patient monitoring needs, particularly in busy departments with a heavy workload may also reduce extravasation risk, and improve management of same. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Balasubramanian, Vijay Anand; Douraiswami, Balaji; Subramani, Suresh
2018-06-01
Lumbar spondylolisthesis is a common cause of morbidity in middle aged individuals. Spinal fusion with instrumentation has become the gold standard for lumbar segmental instability. Studies which correlate the improvement in radiology postoperatively with functional outcome show contrasting reports. This study is aimed at finding the correlation between clinical and radiological outcomes after surgery with transforaminal lumbar interbody fusion. A retrospective study in 35 patients who underwent transforaminal lumbar interbody fusion in a period of 1 year was done. Preoperative pain (VAS Score), functional ability (ODI), radiological parameters (slip angle, slip grade, disc height, foraminal height, lumbar lordosis) were compared with postoperative recordings at the last followup. Functional improvement (Macnab's criteria) and fusion (Lee's fusion criteria) were assessed. Statistical analysis was done with student's paired t -test and Pearson's correlation coefficient. VAS score, ODI improved from 8 to 2 and 70 to 15 respectively. Slip angle improved from 23°to 5° on an average. 80% patients showed fusion and 85% showed good clinical outcome at 1 year followup. Analyzing with Pearson correlation coefficient showed no significant relation between pain scores and radiological parameters. But there was statistically significant relation between radiological fusion and the final clinical outcome. TLIF produces spinal fusion in most individuals. Strong spinal fusion is essential for good clinical outcome in spondylolisthesis patients who undergo TLIF. Reduction in slip is not necessary for all patients with listhesis.
Social Media Utilization at an Academic Radiology Practice.
Koontz, Nicholas A; Kamer, Aaron P; Dodson, Sean C; Capps, Alisha E; Tomblinson, Courtney M; Brown, Brandon P; Frank, Mark S; Heitkamp, Darel E
2018-01-01
We report social media (SoMe) utilization trends at an academic radiology department, highlighting differences between trainees and faculty and between Baby Boomers versus Generation X and Millennials. An anonymous online survey regarding SoMe utilization and SoMe-based educational curriculum was distributed to all radiologists (trainees and faculty) in our department. Regular chi-square, ordered (Mantel-Haenszel) chi-square, and Fischer exact tests were performed. The survey instrument was sent to 172 radiologists with a 65% completion rate (N = 112). Eighty-three percent (n = 92) of the respondents use SoMe, with Facebook (67%, n = 75), YouTube (57%, n = 64), Instagram (26%, n = 29), and Twitter (21%, n = 23) as the most commonly used platforms. Eighty-one percent (n = 91) use SoMe for 30 minutes or less per day. Thirty-five percent (n = 39) reported previously using SoMe for educational purposes, although 66% (n = 73) would be willing to join SoMe for educational activities. The faculty are more likely than trainees to avoid using SoMe (30% vs 9%, P < 0.03). Trainees are more likely than faculty to find an electronic case-based curriculum valuable (95% vs 83%, P < 0.05) and are willing to spend more time on cases (P < 0.01). Baby Boomers are less interested in joining SoMe for educational activities than Generation X and Millennials (24% vs 73%, P = 0.0001). Generation gaps between trainees and faculty, as well as between Generation X and Millennials versus Baby Boomers, exist with regard to the use of SoMe, which may be underutilized in radiology education. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Koontz, Nicholas A; Hill, Danielle V; Dodson, Sean C; Capps, Alisha E; Kamer, Aaron P; Frank, Mark S; Heitkamp, Darel E
2018-06-01
We report the development of a new "Case of the Day" (COTD) educational initiative using email, social media (SoMe), and a website to disseminate content, as well as its trends in viewership and assessment of utility for the first year of implementation. Using an image-rich format, a new unknown case was disseminated to radiology trainees and attendings at our institution by email twice per week, including history, salient images, and follow-up questions. Simultaneously, content was externally disseminated on Twitter and a publicly viewable departmental website. On subsequent days, the answer was posted via email, Twitter, and website in the form of a brief YouTube video lecture. Viewership data were collected over the first 12 months (July 1, 2016 to June 30, 2017), and an anonymous survey of participants was performed. Sixty-five COTDs had complete viewership data and were included in our analysis, yielding 4911 "case" email views (mean = 76), 3798 "answer" email views (mean = 58), 68,034 "case" Twitter impressions (mean = 1047), 75,724 "answer" Twitter impressions (mean = 1164), 5465 "case" Twitter engagements (mean = 84), and 5307 "answer" Twitter engagements (mean = 82). COTD YouTube video lectures garnered 3657 views (mean = 61) amounting to 10,358 minutes of total viewing time. Viewers were very satisfied with COTD quality, with 97% (n = 63) reporting the quality as "good" or "excellent." Email and SoMe can serve as effective tools for disseminating radiology educational content. SoMe offers substantial external visibility and branding potential for programs. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
The imaging spectrum of posterior reversible encephalopathy syndrome: A pictorial review.
Brady, Emily; Parikh, Neal S; Navi, Babak B; Gupta, Ajay; Schweitzer, Andrew D
Posterior reversible encephalopathy syndrome (PRES) is characterized by the acute onset of neurologic symptoms (headache, altered mental status, visual changes, seizures) with accompanying vasogenic edema on brain imaging. Risk factors for PRES include infection, uremia, malignancy, autoimmune disorders, the peripartum state and hypertension. PRES is classically described as being posterior (i.e. parieto-occipital) but radiologic variants are increasingly recognized. This pictorial review demonstrates the heterogeneity of the different radiologic presentations of PRES in reference to lesion distribution, hemorrhage, diffusion restriction, contrast enhancement, and other associated findings. Copyright © 2017 Elsevier Inc. All rights reserved.
Social Media in the Curriculum and Co-Curriculum: Pre-Service Teachers and Their Collegiate Peers
ERIC Educational Resources Information Center
Heiberger, Greg A.
2013-01-01
Although use of social media by students has been shown to be nearly ubiquitous, many K-12 school systems have banned its use on their campuses or use between their teachers and students. In contrast, many collegiate faculty have utilized social media in their teaching. Social media has been shown to assist faculty in engaging with students,…
2016-06-01
media sources on the public discourse. This research compares and contrasts the roles and importance of traditional and social media in the public...alternative media , social media 15. NUMBER OF PAGES 73 16. PRICE CODE 17. SECURITY CLASSIFICATION OF REPORT Unclassified 18. SECURITY...importance of traditional and social media in the public sphere today, as evidenced by the coverage of concealed-carry laws and related stories. The
Al Fagih, Ahmed; Al Ghamdi, Saleh; El Tayeb, Areeg; Dagriri, Khaled
2010-09-01
Rotational angiography is one of the latest angiographic modalities to map the coronary venous tree anatomy. It provides a significant reduction in both contrast agent usage and radiation dose (up to 30%), without compromising the clinical utility of images. Hence, the present study was conducted to describe a new technique to minimize the amount of contrast media used during cardiac resynchronization therapy (CRT) implantation. The SL3 sheath was inserted into the right atrium via the femoral vein followed by withdrawal of the dilator. The tip of the sheath was manipulated to the vicinity of the coronary sinus (CS) ostium (OS). The CS was entered using a deflated balloon catheter. The sheath was then advanced gently beyond the CS OS. Occlusive venography was performed using 5-8 ml of contrast media in a rotational view starting from 45 degrees LAO to 0 degrees AP while holding the inflated balloon for a few seconds. Data from 30 consecutive patients who underwent CRT implantation were analyzed. The feasibility of rotational angiography, while occluding the CS with a specialized long, preshaped sheath and using an ordinary cath-lab imaging machine, was supported by the correctly delineated CS anatomy of all patients without any complications and death related to the placement of the CS catheters or sheaths. The mean contrast dose used for the entire procedure in all patients undergoing CRT was 14.76 +/- 6.8 ml. Use of rotational CS occlusive venography utilizing an ordinary cath-lab X-ray machine minimizes the use of contrast media during CRT implantation without compromising the visualized anatomy.
Strengths and Deficiencies in the Content of US Radiology Private Practices' Websites.
Johnson, Evan J; Doshi, Ankur M; Rosenkrantz, Andrew B
2017-03-01
The Internet provides a potentially valuable mechanism for radiology practices to communicate with patients and enhance the patient experience. The aim of this study was to assess the websites of US radiology private practices, with attention to the frequency of content of potential patient interest. The 50 largest private practice radiology facilities in the United States were identified from RadiologyBusiness.com. Websites were reviewed for information content and functionality. Content regarding radiologists' names, medical schools, residencies, fellowships, photographs, and board certification status; contact for billing questions; and ability to make online payments was present on 80% to 98% of sites. Content regarding examination preparation, contrast use, examination duration, description of examination experience, scheduling information, directions, privacy policy, radiologists' role in interpretation, and ACR accreditation was present on 60% to 78%. Content regarding accepted insurers, delivery of results to referrers, report turnaround times, radiologists' years of experience, radiation safety, and facility hours was present on 40% to 58%. Content regarding technologist certification, registration forms, instructions for requesting a study on disc, educational videos, and patient testimonials was present on 20% to 38%. Content regarding examination prices, patient satisfaction scores, peer review, online scheduling, online report and image access, and parking was present on <20%. Radiology practices' websites most frequently provided information regarding their radiologists' credentials, as well as billing and payment options. Information regarding quality, safety, and the examination experience, as well as non-payment-related online functionality, was less common. These findings regarding the most common deficiencies may be useful for radiology practices in expanding their websites' content, thereby improving communication and potentially the patient experience. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Pfeifer, Kyle; Staib, Lawrence; Arango, Jennifer; Kirsch, John; Arici, Mel; Kappus, Liana; Pahade, Jay
2016-01-01
Reactions to contrast material are uncommon in diagnostic radiology, and vary in clinical presentation from urticaria to life-threatening anaphylaxis. Prior studies have demonstrated a high error rate in contrast reaction management, with smaller studies using simulation demonstrating variable data on effectiveness. We sought to assess the effectiveness of high-fidelity simulation in teaching contrast reaction management for residents, fellows, and attendings. A 20-question multiple-choice test assessing contrast reaction knowledge, with Likert-scale questions assessing subjective comfort levels of management of contrast reactions, was created. Three simulation scenarios that represented a moderate reaction, a severe reaction, and a contrast reaction mimic were completed in a one-hour period in a simulation laboratory. All participants completed a pretest and a posttest at one month. A six-month delayed posttest was given, but was optional for all participants. A total of 150 radiologists participated (residents = 52; fellows = 24; faculty = 74) in the pretest and posttest; and 105 participants completed the delayed posttest (residents = 31; fellows = 17; faculty = 57). A statistically significant increase was found in the one-month posttest (P < .00001) and the six-month posttest scores (P < .00001) and Likert scores (P < .001) assessing comfort level in managing all contrast reactions, compared with the pretest. Test scores and comfort level for moderate and severe reactions significantly decreased at six months, compared with the one-month posttest (P < .05). High-fidelity simulation is an effective learning tool, allowing practice of "high-acuity" situation management in a nonthreatening environment; the simulation training resulted in significant improvement in test scores, as well as an increase in subjective comfort in management of reactions, across all levels of training. A six-month refresher course is suggested, to maintain knowledge and comfort level in contrast reaction management. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Rosenkrantz, Andrew B; Ayoola, Abimbola; Singh, Kush; Duszak, Richard
2017-07-01
Emerging alternative metrics leverage social media and other online platforms to provide immediate measures of biomedical articles' reach among diverse public audiences. We aimed to compare traditional citation and alternative impact metrics for articles in popular general radiology journals. All 892 original investigations published in 2013 issues of Academic Radiology, American Journal of Roentgenology, Journal of the American College of Radiology, and Radiology were included. Each article's content was classified as imaging vs nonimaging. Traditional journal citations to articles were obtained from Web of Science. Each article's Altmetric Attention Score (Altmetric), representing weighted mentions across a variety of online platforms, was obtained from Altmetric.com. Statistical assessment included the McNemar test, the Mann-Whitney test, and the Pearson correlation. Mean and median traditional citation counts were 10.7 ± 15.4 and 5 vs 3.3 ± 13.3 and 0 for Altmetric. Among all articles, 96.4% had ≥1 traditional citation vs 41.8% for Altmetric (P < 0.001). Online platforms for which at least 5% of the articles were represented included Mendeley (42.8%), Twitter (34.2%), Facebook (10.7%), and news outlets (8.4%). Citations and Altmetric were weakly correlated (r = 0.20), with only a 25.0% overlap in terms of articles within their top 10th percentiles. Traditional citations were higher for articles with imaging vs nonimaging content (11.5 ± 16.2 vs 6.9 ± 9.8, P < 0.001), but Altmetric scores were higher in articles with nonimaging content (5.1 ± 11.1 vs 2.8 ± 13.7, P = 0.006). Although overall online attention to radiology journal content was low, alternative metrics exhibited unique trends, particularly for nonclinical articles, and may provide a complementary measure of radiology research impact compared to traditional citation counts. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Computers, Mass Media, and Schooling: Functional Equivalence in Uses of New Media.
ERIC Educational Resources Information Center
Lieberman, Debra A.; And Others
1988-01-01
Presents a study of 156 California eighth grade students which contrasted their recreational and intellectual computer use in terms of academic performance and use of other media. Among the conclusions were that recreational users watched television heavily and performed poorly in school, whereas intellectual users watched less television,…
Mc Laughlin, Patrick; Neill, Siobhan O; Fanning, Noel; Mc Garrigle, Anne Marie; Connor, Owen J O; Wyse, Gerry; Maher, Michael M
2012-04-01
Tablet devices have recently been used in radiological image interpretation because they have a display resolution comparable to desktop LCD monitors. We identified a need to examine tablet display performance prior to their use in preliminary interpretation of radiological images. We compared the spatial and contrast resolution of a commercially available tablet display with a diagnostic grade 2 megapixel monochrome LCD using a contrast detail phantom. We also recorded reporting discrepancies, using the ACR RADPEER system, between preliminary interpretation of 100 emergency CT brain examinations on the tablet display and formal review on a diagnostic LCD. The iPad display performed inferiorly to the diagnostic monochrome display without the ability to zoom. When the software zoom function was enabled on the tablet device, comparable contrast detail phantom scores of 163 vs 165 points were achieved. No reporting discrepancies were encountered during the interpretation of 43 normal examinations and five cases of acute intracranial hemorrhage. There were seven RADPEER2 (understandable) misses when using the iPad display and 12 with the diagnostic LCD. Use of software zoom in the tablet device improved its contrast detail phantom score. The tablet allowed satisfactory identification of acute CT brain findings, but additional research will be required to examine the cause of "understandable" reporting discrepancies that occur when using tablet devices.
Picard, Melissa; Curry, Nancy; Collins, Heather; Soma, LaShonda; Hill, Jeanne
2015-10-01
Simulation-based training has been shown to be a useful adjunct to standard didactic lecture in teaching residents appropriate management of adverse contrast reactions. In addition, it has been suggested that a biannual refresher is needed; however, the type of refresher education has not been assessed. This was a prospective study involving 31 radiology residents across all years in a university program. All residents underwent standard didactic lecture followed by high-fidelity simulation-based training. At approximately 6 months, residents were randomized into a didactic versus simulation group for a refresher. At approximately 9 months, all residents returned to the simulation center for performance testing. Knowledge and confidence assessments were obtained from all participants before and after each phase. Performance testing was obtained at each simulation session and scored based on predefined critical actions. There was significant improvement in knowledge (P < .002) and confidence (P < .001) after baseline education of combined didactic and simulation-based training. There was no statistical difference between the simulation and didactic groups in knowledge or confidence at any phase of the study. There was no significant difference in tested performance between the groups in either performance testing session. This study suggests that a curriculum consisting of an annual didactic lecture combined with simulation-based training followed by a didactic refresher at 6 months is an effective and efficient (both cost-effective and time-effective) method of educating radiology residents in the management of adverse contrast reactions. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Milk of calcium stones: radiological signs and management outcome.
El-Shazly, M
2015-06-01
Milk of calcium (MOC) is a rare type of stone that was first described in 1940 by Ludin and Howald who reported MOC in renal cysts. Milk of calcium is a viscous colloidal suspension of calcium salts. Stasis, obstruction and infection are important predisposing factors. Due to a layering effect, characteristic radiological signs especially in CT can help in diagnosis to avoid unsuccessful shock wave lithotripsy. This is the largest reported case series, in which radiological signs by CT scan to predict renal MOC stones, clinical picture and management outcome are described in detail. Cases with suspected renal milk of calcium stones were studied over 7 years (2008-2015). All cases were diagnosed preoperatively by non-contrast CT. Urine cultures were performed in all patients preoperatively. Intra-operative and postoperative findings were reported. Stones retrieved were sent for chemical analysis using an infrared method. Seven cases of milk of calcium renal stones were included in this study. These stones were faint radio-opaque in two cases and radiolucent in five cases. All cases were diagnosed preoperatively with non-contrast CT. Their Hounsfield units (HU) ranged from 114 to 612. All stones were located in a dependent position (gravitational effect) in the posterior aspect of dilated calyces. Five cases exhibited the typical fluid level and two cases demonstrated semilunar (half moon) pattern in the anterior surface of the stones. All cases underwent PCNL with suction and retrieval of soft stones without the need for disintegration. When stones demonstrate a low Hounsfield unit, are arranged in dependent positions within dilated calyces and exhibit fluid level or semilunar pattern on non-contrast CT, milk of calcium stones should be considered. PCNL is an effective modality for management of renal milk of calcium stones.
Blumfield, Einat; Moore, Michael M; Drake, Mary K; Goodman, Thomas R; Lewis, Kristopher N; Meyer, Laura T; Ngo, Thang D; Sammet, Christina; Stanescu, Arta Luana; Swenson, David W; Slovis, Thomas L; Iyer, Ramesh S
2017-05-01
Gadolinium-based contrast agents (GBCAs) have been used for magnetic resonance (MR) imaging over the last three decades. Recent reports demonstrated gadolinium retention in patients' brains following intravenous administration. Since gadolinium is a highly toxic heavy metal, there is a potential for adverse effects from prolonged retention or deposition, particularly in children. For this reason, the Society (SPR) for Pediatric Radiology Quality and Safety committee conducted a survey to evaluate the current status of GBCAs usage among pediatric radiologists. To assess the usage of GBCAs among SPR members. An online 15-question survey was distributed to SPR members. Survey questions pertained to the type of GBCAs used, protocoling workflow, requirement of renal function or pregnancy tests, and various clinical indications for contrast-enhanced MRI examinations. A total of 163 survey responses were compiled (11.1% of survey invitations), the majority of these from academic institutions in the United States. Ninety-four percent reported that MR studies are always or usually protocoled by pediatric radiologists. The most common GBCA utilized by survey respondents were Eovist (60.7%), Ablavar (45.4%), Gadovist (38.7%), Magnevist (34.4%) and Dotarem (32.5%). For several clinical indications, survey responses regarding GBCA administration were concordant with American College of Radiology (ACR) Appropriateness Criteria, including seizures, headache and osteomyelitis. For other indications, including growth hormone deficiency and suspected vascular ring, survey responses revealed potential overutilization of GBCAs when compared to ACR recommendations. Survey results demonstrate that GBCAs are administered judiciously in children, yet there is an opportunity to improve their utilization with the goal of reducing potential future adverse effects.
Altman, Daniel; López, Annika; Kierkegaard, Jonas; Zetterström, Jan; Falconer, Christian; Pollack, Johan; Mellgren, Anders
2005-01-01
The aim of the present study was to compare clinical and radiological findings when assessing posterior vaginal wall prolapse. Defecography can be used to complement the clinical evaluation in patients with posterior vaginal wall prolapse. Further development of the defecography technique, using contrast medium in the urinary bladder and intraperitoneally, have resulted in cystodefecoperitoneography (CDP). Thirty-eight women underwent clinical examination using the pelvic organ prolapse quantification system (POP-Q) followed by CDP. All patients answered a standardized bowel function questionnaire. Statistical analysis measuring correlation between POP-Q and CDP using Pearson's correlation coefficient (r) and Spearman's rank order correlation coefficient (rs) demonstrated a poor to moderate correlation, r=0.49 and rs=0.55. Although there was a strong association between large rectoceles (>3 cm) at CDP and symptoms of rectal emptying difficulties (p<0.001), severity and prevalence of bowel dysfunction showed poor coherence with clinical prolapse staging and findings at radiological imaging. Vaginal topography and POP-Q staging predict neither radiological size nor visceral involvement in posterior vaginal wall prolapse. Radiological evaluation may therefore be a useful complement in selected patients.
Villanueva Campos, A M; Tardáguila de la Fuente, G; Utrera Pérez, E; Jurado Basildo, C; Mera Fernández, D; Martínez Rodríguez, C
To analyze whether there are significant differences in the objective quantitative parameters obtained in the postprocessing of dual-energy CT enterography studies between bowel segments with radiologic signs of Crohn's disease and radiologically normal segments. This retrospective study analyzed 33 patients (16 men and 17 women; mean age 54 years) with known Crohn's disease who underwent CT enterography on a dual-energy scanner with oral sorbitol and intravenous contrast material in the portal phase. Images obtained with dual energy were postprocessed to obtain color maps (iodine maps). For each patient, regions of interest were traced on these color maps and the density of iodine (mg/ml) and the fat fraction (%) were calculated for the wall of a pathologic bowel segment with radiologic signs of Crohn's disease and for the wall of a healthy bowel segment; the differences in these parameters between the two segments were analyzed. The density of iodine was lower in the radiologically normal segments than in the pathologic segments [1.8 ± 0.4mg/ml vs. 3.7 ± 0.9mg/ml; p<0.05]. The fat fraction was higher in the radiologically normal segments than in the pathologic segments [32.42% ± 6.5 vs. 22.23% ± 9.4; p<0.05]. There are significant differences in the iodine density and fat fraction between bowel segments with radiologic signs of Crohn's disease and radiologically normal segments. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Mihl, Casper; Wildberger, Joachim E; Jurencak, Tomas; Yanniello, Michael J; Nijssen, Estelle C; Kalafut, John F; Nalbantov, Georgi; Mühlenbruch, Georg; Behrendt, Florian F; Das, Marco
2013-11-01
Both iodine delivery rate (IDR) and iodine concentration are decisive factors for vascular enhancement in computed tomographic angiography. It is unclear, however, whether the use of high-iodine concentration contrast media is beneficial to lower iodine concentrations when IDR is kept identical. This study evaluates the effect of using different iodine concentrations on intravascular attenuation in a circulation phantom while maintaining a constant IDR. A circulation phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used (heart rate, 60 beats per minute; stroke volume, 60 mL; blood pressure, 120/80 mm Hg). Maintaining a constant IDR (2.0 g/s) and a constant total iodine load (20 g), prewarmed (37°C) contrast media with differing iodine concentrations (240-400 mg/mL) were injected into the phantom using a double-headed power injector. Serial computed tomographic scans at the level of the ascending aorta (AA), the descending aorta (DA), and the left main coronary artery (LM) were obtained. Total amount of contrast volume (milliliters), iodine delivery (grams of iodine), peak flow rate (milliliter per second), and intravascular pressure (pounds per square inch) were monitored using a dedicated data acquisition program. Attenuation values in the AA, the DA, and the LM were constantly measured (Hounsfield unit [HU]). In addition, time-enhancement curves, aortic peak enhancement, and time to peak were determined. All contrast injection protocols resulted in similar attenuation values: the AA (516 [11] to 531 [37] HU), the DA (514 [17] to 531 [32] HU), and the LM (490 [10] to 507 [17] HU). No significant differences were found between the AA, the DA, and the LM for either peak enhancement (all P > 0.05) or mean time to peak (AA, 19.4 [0.58] to 20.1 [1.05] seconds; DA, 21.1 [1.0] to 21.4 [1.15] seconds; LM, 19.8 [0.58] to 20.1 [1.05] seconds). This phantom study demonstrates that constant injection parameters (IDR, overall iodine load) lead to robust enhancement patterns, regardless of the contrast material used. Higher iodine concentration itself does not lead to higher attenuation levels. These results may stimulate a shift in paradigm toward clinical usage of contrast media with lower iodine concentrations (eg, 240 mg iodine/mL) in individual tailored contrast protocols. The use of low-iodine concentration contrast media is desirable because of the lower viscosity and the resulting lower injection pressure.
Bolognese, Leonardo; Falsini, Giovanni; Schwenke, Carsten; Grotti, Simone; Limbruno, Ugo; Liistro, Francesco; Carrera, Arcangelo; Angioli, Paolo; Picchi, Andrea; Ducci, Kenneth; Pierli, Carlo
2012-01-01
Conflicting data have been reported on the effects of low-osmolar and iso-osmolar contrast media on contrast-induced acute kidney injury (CI-AKI). In particular, no clinical trial has yet focused on the effect of contemporary contrast media on CI-AKI, epicardial flow, and microcirculatory function in patients with ST-segment elevation acute myocardial infarction who undergo primary percutaneous coronary intervention. The Contrast Media and Nephrotoxicity Following Coronary Revascularization by Angioplasty for Acute Myocardial Infarction (CONTRAST-AMI) trial is a prospective, randomized, single-blind, parallel-group, noninferiority study aiming to evaluate the effects of the low-osmolar contrast medium iopromide compared to the iso-osmolar agent iodixanol on CI-AKI and tissue-level perfusion in patients with ST-segment elevation acute myocardial infarction. Four hundred seventy-five consecutive, unselected patients who underwent primary percutaneous coronary intervention were randomized to iopromide (n = 239) or iodixanol (n = 236). All patients received high-dose N-acetylcysteine and hydration. The primary end point was the proportion of patients with serum creatinine (sCr) increases ≥25% from baseline to 72 hours. Secondary end points were Thrombolysis In Myocardial Infarction (TIMI) myocardial perfusion grade, increase in sCr ≥50%, increase in sCr ≥0.5 or ≥1 mg/dl, and 1-month major adverse cardiac events. The primary end point occurred in 10% of the iopromide group and in 13% of the iodixanol group (95% confidence interval -9% to 3%, p for noninferiority = 0.0002). A TIMI myocardial perfusion grade of 0 or 1 was present in 14% of patients in the 2 groups. No differences between the 2 groups were found in any of the secondary analyses of sCr increase. No significant difference in 1-month major adverse cardiac events was found (8% vs 6%, p = 0.37). In conclusion, in a population of unselected patients with ST-segment elevation acute myocardial infarction who underwent primary percutaneous coronary intervention, iopromide was not inferior to iodixanol in the occurrence of CI-AKI; no significant differences were found in terms of tissue-level reperfusion and major adverse cardiac events between the 2 contrast agents. Copyright © 2012 Elsevier Inc. All rights reserved.
Hypersensitivity to contrast media and dyes.
Brockow, Knut; Sánchez-Borges, Mario
2014-08-01
This article updates current knowledge on hypersensitivity reactions to diagnostic contrast media and dyes. After application of a single iodinated radiocontrast medium (RCM), gadolinium-based contrast medium, fluorescein, or a blue dye, a hypersensitivity reaction is not a common finding; however, because of the high and still increasing frequency of those procedures, patients who have experienced severe reactions are nevertheless frequently encountered in allergy departments. Evidence on allergologic testing and management is best for iodinated RCM, limited for blue dyes, and insufficient for fluorescein. Skin tests can be helpful in the diagnosis of patients with hypersensitivity reactions to these compounds. Copyright © 2014 Elsevier Inc. All rights reserved.
Tissue specific MR contrast media role in the differential diagnosis of cirrhotic liver nodules.
Lupescu, Ioana Gabriela; Capsa, Razvan A; Gheorghe, Liana; Herlea, Vlad; Georgescu, Serban A
2008-09-01
State-of-the-art magnetic resonance (MR) imaging using tissue specific contrast media facilitates detection and characterization in most cases of hepatic nodules. According to the currently used nomenclature, in liver cirrhosis there are only two major types of hepatocellular nodular lesions: regenerative lesions and dysplastic or neoplastic lesions. The purpose of this clinical imaging review is to provide information on the properties of tissue-specific MR contrast agents and on their usefulness in the demonstration of the pathologic changes that take place at the level of the hepatobiliary and reticuloendothelial systems during the carcinogenesis in liver cirrhosis.
Burton, Kirsteen R; Perlis, Nathan; Aviv, Richard I; Moody, Alan R; Kapral, Moira K; Krahn, Murray D; Laupacis, Andreas
2014-03-01
This study reviews the quality of economic evaluations of imaging after acute stroke and identifies areas for improvement. We performed full-text searches of electronic databases that included Medline, Econlit, the National Health Service Economic Evaluation Database, and the Tufts Cost Effectiveness Analysis Registry through July 2012. Search strategy terms included the following: stroke*; cost*; or cost-benefit analysis*; and imag*. Inclusion criteria were empirical studies published in any language that reported the results of economic evaluations of imaging interventions for patients with stroke symptoms. Study quality was assessed by a commonly used checklist (with a score range of 0% to 100%). Of 568 unique potential articles identified, 5 were included in the review. Four of 5 articles were explicit in their analysis perspectives, which included healthcare system payers, hospitals, and stroke services. Two studies reported results during a 5-year time horizon, and 3 studies reported lifetime results. All included the modified Rankin Scale score as an outcome measure. The median quality score was 84.4% (range=71.9%-93.5%). Most studies did not consider the possibility that patients could not tolerate contrast media or could incur contrast-induced nephropathy. Three studies compared perfusion computed tomography with unenhanced computed tomography but assumed that outcomes guided by the results of perfusion computed tomography were equivalent to outcomes guided by the results of magnetic resonance imaging or noncontrast computed tomography. Economic evaluations of imaging modalities after acute ischemic stroke were generally of high methodological quality. However, important radiology-specific clinical components were missing from all of these analyses.
Wild, C; Puig, S
2004-11-01
In the context of increasing economic pressure upon on hospital budgets, it is inevitable that central and standardized purchasing of pharmaceuticals must be considered. It was the aim of this assessment to analyse the many different non-ionic contrast media/CM products on the actual "clinical relevance of the differences" in order to give advice for a more concerted purchasing of CM. The assessment was commissioned by a large scale Austrian hospital cooperation; it can be regarded as the beginning of a broad strategy against the many new, only rarely innovative, but nevertheless patent-protected pharmaceuticals. Eight different non-ionic contrast media - used in routine care - were compared for their physico-chemical characteristics: osmolality, nephrotoxicity, viscosity, hydrophilicity and electric charge. In a systematic review 193 publications were analysed. The examined CM show similar pharmacokinetic and -dynamic attributes, and no differences of clinical relevance. An optimisation of purchasing pharmaceuticals by standardisation of the range of products takes place in the context of common strategies of producers and buying agents in marketing-economies. The strategies of the pharmaceutical industry (patent protection of me-too drugs, high-price-policy, extensive marketing of up to 40 % of revenue) and the counter-strategies of the central hospital purchasers (market concentration, drug commissions, institutional measures to disentangle interests) are presented - exemplified by contrast media - in this article.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arendt, Dustin L.; Volkova, Svitlana
Analyzing and visualizing large amounts of social media communications and contrasting short-term conversation changes over time and geo-locations is extremely important for commercial and government applications. Earlier approaches for large-scale text stream summarization used dynamic topic models and trending words. Instead, we rely on text embeddings – low-dimensional word representations in a continuous vector space where similar words are embedded nearby each other. This paper presents ESTEEM,1 a novel tool for visualizing and evaluating spatiotemporal embeddings learned from streaming social media texts. Our tool allows users to monitor and analyze query words and their closest neighbors with an interactive interface.more » We used state-of- the-art techniques to learn embeddings and developed a visualization to represent dynamically changing relations between words in social media over time and other dimensions. This is the first interactive visualization of streaming text representations learned from social media texts that also allows users to contrast differences across multiple dimensions of the data.« less
Saade, Charbel; Mohamad, May; Kerek, Racha; Hamieh, Nadine; Alsheikh Deeb, Ibrahim; El-Achkar, Bassam; Tamim, Hani; Abdul Razzak, Farah; Haddad, Maurice; Abi-Ghanem, Alain S; El-Merhi, Fadi
The aim of this article was to investigate the opacification of the renal vasculature and the urogenital system during computed tomography urography by using a quadruple-phase contrast media in a triphasic scan protocol. A total of 200 patients with possible urinary tract abnormalities were equally divided between 2 protocols. Protocol A used the conventional single bolus and quadruple-phase scan protocol (pre, arterial, venous, and delayed), retrospectively. Protocol B included a quadruple-phase contrast media injection with a triphasic scan protocol (pre, arterial and combined venous, and delayed), prospectively. Each protocol used 100 mL contrast and saline at a flow rate of 4.5 mL. Attenuation profiles and contrast-to-noise ratio of the renal arteries, veins, and urogenital tract were measured. Effective radiation dose calculation, data analysis by independent sample t test, receiver operating characteristic, and visual grading characteristic analyses were performed. In arterial circulation, only the inferior interlobular arteries in both protocols showed a statistical significance (P < 0.05). Venously, the inferior vena cava, proximal and distal renal veins demonstrated a significant opacification reduction in protocol B than in protocol A (P < 0.001). Protocol B showed a significantly higher mean contrast-to-noise ratio than protocol A (protocol B: 22.68 ± 13.72; protocol A: 14.75 ± 5.76; P < 0.001). Radiation dose was significantly reduced in protocol B (7.38 ± 2.22 mSv) than in protocol A (12.28 ± 2.72 mSv) (P < 0.001). Visual grading characteristic (P < 0.027) and receiver operating characteristic (P < 0.0001) analyses demonstrated a significant preference for protocol B. In computed tomography urography, augmented quadruple-phase contrast media and triphasic scan protocol usage increases the image quality at a reduced radiation dose.
Sadeghi, Mohsen Mirmohammad; Gharipour, Mojgan; Nilforoush, Peiman; Shamsolkotabi, Hamid; Sadeghi, Hamid Mirmohammad; Kiani, Amjad; Sadeghi, Pouya Mirmohammad; Farahmand, Niloufar
2011-04-01
There is limited data about the influence of timing of cardiac surgery in relation to diagnostic angiography and/or the impact of the amount of contrast media used during angiography on the occurance of acute renal failure (ARF). Therefore, in the present study the effect of the time interval between diagnostic angiography and cardiac surgery and also the amount of contrast media used during the diagnostic procedure on the incidence of ARF after cardiac surgery was investigated. Data of 1177 patients who underwent different types of cardiac surgeries after cardiac catheterization were prospectively examined. The influence of time interval between cardiac catheterization and surgery as well as the amount of contrast agent on postoperative ARF were assessed using multivariable logistic regression. The patients who progressed to ARF were more likely to have received a higher dose of contrast agent compared to the mean dose. However, the time interval between cardiac surgery and last catheterization was not significantly different between the patients with and without ARF (p = 0.05). Overall, postoperative peak creatinine was highest on day 0, then decreased and remained significantly unchanged after this period. Overall prevalence of acute renal failure during follow-up period had a changeable trend and had the highest rates in days 1 (53.57%) and 6 (52.17%) after surgery. Combined coronary bypass and valve surgery were the strongest predictor of postoperative ARF (OR: 4.976, CI = 1.613-15.355 and p = 0.002), followed by intra-aortic balloon pump insertion (OR: 6.890, CI = 1.482-32.032 and p = 0.009) and usage of higher doses of contrast media agent (OR: 1.446, CI = 1.033-2.025 and p = 0.031). Minimizing the amount of contrast agent has a potential role in reducing the incidence of postoperative ARF in patients undergoing cardiac surgery, but delaying cardiac surgery after exposure to these agents might not have this protective effect.
Usage of CO2 microbubbles as flow-tracing contrast media in X-ray dynamic imaging of blood flows.
Lee, Sang Joon; Park, Han Wook; Jung, Sung Yong
2014-09-01
X-ray imaging techniques have been employed to visualize various biofluid flow phenomena in a non-destructive manner. X-ray particle image velocimetry (PIV) was developed to measure velocity fields of blood flows to obtain hemodynamic information. A time-resolved X-ray PIV technique that is capable of measuring the velocity fields of blood flows under real physiological conditions was recently developed. However, technical limitations still remained in the measurement of blood flows with high image contrast and sufficient biocapability. In this study, CO2 microbubbles as flow-tracing contrast media for X-ray PIV measurements of biofluid flows was developed. Human serum albumin and CO2 gas were mechanically agitated to fabricate CO2 microbubbles. The optimal fabricating conditions of CO2 microbubbles were found by comparing the size and amount of microbubbles fabricated under various operating conditions. The average size and quantity of CO2 microbubbles were measured by using a synchrotron X-ray imaging technique with a high spatial resolution. The quantity and size of the fabricated microbubbles decrease with increasing speed and operation time of the mechanical agitation. The feasibility of CO2 microbubbles as a flow-tracing contrast media was checked for a 40% hematocrit blood flow. Particle images of the blood flow were consecutively captured by the time-resolved X-ray PIV system to obtain velocity field information of the flow. The experimental results were compared with a theoretically amassed velocity profile. Results show that the CO2 microbubbles can be used as effective flow-tracing contrast media in X-ray PIV experiments.
Abnormal gel flotation caused by contrast media during adrenal vein sampling.
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Gelati, Matteo; Bassi, Antonella; Contro, Alberto; Pizzolo, Francesca; Guidi, Gian Cesare
2016-10-15
During adrenal venous sampling (AVS) procedure, radiologists administer a contrast agent via the catheter to visualize the proper catheter position. A patient with primary aldosteronism diagnostic-hypothesis was admitted for AVS. A venogram was performed to confirm the catheter's position with 2mL of Iopamidol 300 mg/mL. Samples were collected with syringe connected to a hydrophilic coated catheter by low-pressure aspiration from each of the four collection sites: inferior vena cava in the suprarenal portion, inferior vena cava in the infrarenal portion, left adrenal vein, and right adrenal vein; then immediately transferred from syringe to tubes with gel separator. All tubes were centrifuged at 1200 x g for 10 minutes. At the end of centrifugation process, primary blood tubes containing blood from inferior vena cava and left adrenal vein exhibited the standard gel separator barrier, while tubes from right adrenal vein showed abnormal flotation of gel separator. The radiologist confirmed the usage of 2.6 mL instead of 2.0 mL of Iopamidol 300 mg/mL. This iodinated contrast media, with 1.33 g/cm 3 of density, was used close to the right adrenal vein due to some difficulty to access it. The abnormal flotation of gel separator in samples taken from right adrenal vein can be explained by the usage of the iodinated contrast media. We suggest using plain-tubes (without gel separator) for AVS in order to avoid preanalytical nonconformities. Moreover, a blood volume equivalent to twice the catheter extension should be discarded to eliminate residual contrast media before collection of samples for laboratory assays.
The value of radiology in predicting gallstone type when selecting patients for medical treatment.
Bell, G D; Dowling, R H; Whitney, B; Sutor, D J
1975-01-01
Since medical treatment of gallstones is confined to cholesterol-rich stones, the ability of clinical radiographs to predict gallstone type was tested prospectively by comparing the preoperative radiological appearance of gallstones from 57 unselected patients with cholelithiasis coming to cholecystectomy with the subsequent analysis of the stones both by X-ray diffraction and by chemical techniques. Fifty-two per cent of the patients had 'non-functioning' gallbladders which failed to opacify after at least two contrast examinations and 25 out of 50 had radioopaque stones. Of the 25 patients with radiolucent stones, the stones in 20 ((80%) were predominantly cholesterol in type but radiology was misleading in five; three contained 40-55% calcium salts but were still radiolucent while two were amorphous and contained less than 10% cholesterol by weight on chemical analysis. While radiology was sometimes misleading when the stones were small and irregular, large radiolucent stones with a smooth profile were invariably cholesterol-rich stones. The results also show that in men calcified stones were commoner than in women and that in older women the gallstones contained more calcium salts and less cholesterol than in younger women less than 50 yr). This paper analyses critically the value and limitations of clinical radiology in predicting gallstone type. PMID:1140634
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunnick, N.R.; McCallum, R.W.; Sandler, C.M.
1991-01-01
This book provides the practicing radiologist and the radiology resident with a comprehensive text of manageable size that integrates all aspects of adult uroradiology. Topics covered include: anatomy, embryology, and cogenital anomalies of the urinary tract; techniques for imaging of the urinary tract; contrast material; pathologies; and interventional uroradiology.
Image degradation by glare in radiologic display devices
NASA Astrophysics Data System (ADS)
Badano, Aldo; Flynn, Michael J.
1997-05-01
No electronic devices are currently available that can display digital radiographs without loss of visual information compared to traditional transilluminated film. Light scattering within the glass faceplate of cathode-ray tube (CRT) devices causes excessive glare that reduces image contrast. This glare, along with ambient light reflection, has been recognized as a significant limitation for radiologic applications. Efforts to control the effect of glare and ambient light reflection in CRTs include the use of absorptive glass and thin film coatings. In the near future, flat panel displays (FPD) with thin emissive structures should provide very low glare, high performance devices. We have used an optical Monte Carlo simulation to evaluate the effect of glare on image quality for typical CRT and flat panel display devices. The trade-off between display brightness and image contrast is described. For CRT systems, achieving good glare ratio requires a reduction of brightness to 30-40 percent of the maximum potential brightness. For FPD systems, similar glare performance can be achieved while maintaining 80 percent of the maximum potential brightness.
Imaging and interventions in hilar cholangiocarcinoma: A review
Madhusudhan, Kumble Seetharama; Gamanagatti, Shivanand; Gupta, Arun Kumar
2015-01-01
Hilar cholangiocarcinoma is a common malignant tumor of the biliary tree. It has poor prognosis with very low 5-year survival rates. Various imaging modalities are available for detection and staging of the hilar cholangiocarcinoma. Although ultrasonography is the initial investigation of choice, imaging with contrast enhanced computed tomography scan or magnetic resonance imaging is needed prior to management. Surgery is curative wherever possible. Radiological interventions play a role in operable patients in the form of biliary drainage and/or portal vein embolization. In inoperable cases, palliative interventions include biliary drainage, biliary stenting and intra-biliary palliative treatment techniques. Complete knowledge of application of various imaging modalities available and about the possible radiological interventions is important for a radiologist to play a critical role in appropriate management of such patients.We review the various imaging techniques and appearances of hilar cholangiocarcinoma and the possible radiological interventions. PMID:25729485
[Teleradiology - update 2014].
Pinto dos Santos, D; Hempel, J-M; Kloeckner, R; Düber, C; Mildenberger, P
2014-05-01
Due to economic considerations and thanks to technological advances there is a growing interest in the integration of teleradiological applications into the regular radiological workflow. The legal and technical hurdles which are still to be overcome are being discussed in politics as well as by national and international radiological societies. The European Commission as well as the German Federal Ministry of Health placed a focus on telemedicine with their recent eHealth initiatives. The European Society of Radiology (ESR) recently published a white paper on teleradiology. In Germany §3 section 4 of the Röntgenverordnung (RöV, X-ray regulations) and DIN 6868-159 set a framework in which teleradiology can also be used for primary reads. These possibilities are already being used by various networks and some commercial providers across Germany. With regards to cross-border teleradiology, which currently stands in contrast to the RöV, many issues remain unsolved.
Immediate reactions following iodinated contrast media injection: a study of 38 cases.
Dewachter, Pascale; Laroche, Dominique; Mouton-Faivre, Claudie; Bloch-Morot, Evelyne; Cercueil, Jean-Pierre; Metge, Liliane; Carette, Marie-France; Vergnaud, Marie-Claude; Clément, Olivier
2011-03-01
To investigate the pathomechanisms involved in cases of immediate hypersensitivity reactions occurring after the administration of iodinated contrast media. Patients having presented clinical signs of immediate hypersensitivity suggesting allergy after iodinated contrast medium were investigated. Histamine and tryptase concentrations were measured, and/or skin tests were performed. Patients with positive skin tests to the culprit contrast agent were classified as IgE-mediated allergic hypersensitivity (Group I) and patients with negative skin tests as non-allergic hypersensitivity (Group II). 38 patients were included. Most reactions appeared after non-ionic (n = 32). Reactions were more frequently severe following ionic than non-ionic (p = 0.014). Skin testing was not performed in 11 patients. Skin tests with the culprit contrast agent were negative in 26% of the patients (Group II, n = 7) whereas they were found positive with the contrast agent in 73% of the patients (Group I, n = 19). Latex-induced reaction was diagnosed in one patient, and was consequently excluded from the cohort. In Group I, the frequency of cross-reactivity with the other commercialized iodinated contrast media was low (7%). Cardiovascular signs were present in Group I (52.6%, n = 10), and absent in Group II (p = 0.023). Histamine and tryptase concentrations were higher in patients who had cardiovascular signs (p < 0.02). Immediate reactions with clinical signs suggesting allergy along with positive skin tests with the administered contrast agent confirm immediate allergic hypersensitivity (anaphylaxis) to this agent. Consequently, the culprit contrast agent should be definitely avoided as well as cross-reactive ICM in order to prevent further recurrences. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Effects of diatrizoate and iopamidol on spermatogenesis.
Yaghmai, V; Harapanhalli, R S; Patel, Y D; Baker, S R; Rao, D V
1993-12-01
The biological effects of iodinated contrast media were examined by using spermatogenesis in mouse testis as the experimental model. Spermhead survival and abnormality assays were used as the biological end points. Diatrizoate meglumine/diatrizoate sodium and iopamidol were administered intravenously at equal rates and concentrations. Testicular uptake and clearance of these contrast agents were examined by high-performance liquid chromatography techniques. Appropriate mannitol solutions were employed as osmolality controls. Intravenous administration of the contrast agent or its respective mannitol control resulted in approximately a 30% decrease in spermhead count. A dose-related experiment with mannitol demonstrated that the spermhead count decreased rapidly until 600 mOsm/kg was reached, beyond which this decrease was minimal. Clearance of both contrast media was complete in approximately 4 hours. No significant increase in the induction of spermhead abnormalities was observed. Osmotic substances, such as iodinated contrast agents, affect the process of spermatogenesis.
Cardoso-Leite, Pedro; Kludt, Rachel; Vignola, Gianluca; Ma, Wei Ji; Green, C Shawn; Bavelier, Daphne
2016-01-01
Technology has the potential to impact cognition in many ways. Here we contrast two forms of technology usage: (1) media multitasking (i.e., the simultaneous consumption of multiple streams of media, such a texting while watching TV) and (2) playing action video games (a particular subtype of video games). Previous work has outlined an association between high levels of media multitasking and specific deficits in handling distracting information, whereas playing action video games has been associated with enhanced attentional control. Because these two factors are linked with reasonably opposing effects, failing to take them jointly into account may result in inappropriate conclusions as to the impacts of technology use on attention. Across four tasks (AX-continuous performance, N-back, task-switching, and filter tasks), testing different aspects of attention and cognition, we showed that heavy media multitaskers perform worse than light media multitaskers. Contrary to previous reports, though, the performance deficit was not specifically tied to distractors, but was instead more global in nature. Interestingly, participants with intermediate levels of media multitasking sometimes performed better than both light and heavy media multitaskers, suggesting that the effects of increasing media multitasking are not monotonic. Action video game players, as expected, outperformed non-video-game players on all tasks. However, surprisingly, this was true only for participants with intermediate levels of media multitasking, suggesting that playing action video games does not protect against the deleterious effect of heavy media multitasking. Taken together, these findings show that media consumption can have complex and counterintuitive effects on attentional control.
Cardoso-Leite, Pedro; Kludt, Rachel; Vignola, Gianluca; Ma, Wei Ji; Green, C. Shawn; Bavelier, Daphne
2015-01-01
Technology has the potential to impact cognition in many ways. Here we contrast two forms of technology usage: 1) media multitasking (i.e., the simultaneous consumption of multiple streams of media, such a texting while watching TV) and 2) playing action video games (a particular sub-type of video game). Previous work has outlined an association between high levels of media multitasking and specific deficits in handling distracting information, while playing action video games has been associated with enhanced attentional control. As these two factors are linked with reasonably opposing effects, failing to take them jointly into account may result in inappropriate conclusions as to the impact of technology use on attention. Across four experiments (AX-CPT, N-back, Task-switching and Filter task), testing different aspects of attention and cognition, we show that heavy media multitaskers perform worse than light media multitaskers. Contrary to previous reports though, the performance deficit was not specifically tied to distractors, but was instead more global in nature. Interestingly, participants with intermediate levels of media multitasking occasionally performed better than both light and heavy media multitaskers suggesting that the effects of increasing media multitasking are not monotonic. Action video game players, as expected, outperformed non-video game players on all tasks. However, surprisingly this was true only for participants with intermediate levels of media multitasking, suggesting that playing action video games does not protect against the deleterious effect of heavy media multitasking. Taken together this study shows that media consumption can have complex and counter-intuitive effects on attentional control. PMID:26474982
Gender Trends in Academic Radiology Publication in the United States Revisited.
O'Connor, Erin E; Chen, Pauline; Weston, Brian; Anderson, Redmond; Zeffiro, Timothy; Ahmed, Awad; Zeffiro, Thomas A
2018-02-12
Although substantial increases in publications by female academic radiologists have appeared over the last several decades, it is possible that the rate of increase is decreasing. We examined temporal trends in gender composition for full-time radiology faculty, radiology residents, and medical students over a 46-year period. We examined authorship gender trends to determine if the increases in female authorship seen since 1970 have been sustained in recent years and whether female radiologists continue to publish in proportion to their numbers in academic departments. Original articles for selected years in Radiology and in the American Journal of Roentgenology between 1970 and 2016 were examined to determine the gender of first, corresponding, and last authors. Generalized linear models evaluated (1) changes in proportions of female authorship over time and (2) associations between proportions of female authorship and female radiology faculty representation. While linear increases in first, corresponding, and senior authorships were observed for female radiologists from 1970 to 2000, the rate of increase in female first and corresponding authorships then changed, with the slope of the first author relationship decreasing from 0.81 to 0.34, corresponding to 47% fewer female first authors added per year. In contrast, the proportion of female last authorship continued to increase at the same rate. The proportion of female first authorship was linearly related to the proportion of female radiology faculty from 1970 to 2016. Annual increases in first author academic productivity of female radiologists have lessened in the past 16 years, possibly related to reductions in the growth of female radiology faculty and trainees. As mixed, compared to homogeneous gender, authorship teams are associated with more citations, efforts to encourage more women to pursue careers in academic radiology could benefit the radiology research community. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Celik, Omer; Ozturk, Derya; Akin, Fatih; Ayca, Burak; Yalcın, Ahmet Arif; Erturk, Mehmet; Bıyık, Ismail; Ayaz, Ahmet; Akturk, Ibrahim Faruk; Enhos, Asım; Aslan, Serkan
2015-07-01
We hypothesized that contrast media volume-estimated glomerular filtration rate (CV-e-GFR) ratio may be a predictor of contrast media-induced acute kidney injury (CI-AKI). We investigated the associations between CV-e-GFR ratio and CI-AKI in 597 patients undergoing primary percutaneous coronary intervention (pPCI). An absolute ≥0.3 mg/dL increase in serum creatinine compared with baseline levels within 48 hours after the procedure was considered as CI-AKI; 78 (13.1%) of the 597 patients experienced CI-AKI. The amount of contrast during procedure was higher in the CI-AKI group than in those without CI-AKI (153 vs 135 mL, P = .003). The CV-e-GFR ratio was significantly higher in patients with CI-AKI than without (2.3 vs 1.5, P < .001). In multivariate analysis, independent predictors of CI-AKI were low left ventricular ejection fraction (P = .018, odds ratio [OR] = 0.966), e-GFR <60 mL/min (P = .012, OR = 2.558), and CV-e-GFR >2 (P < .001, OR = 5.917). In conclusion, CV-e-GFR ratio is significantly associated with CI-AKI after pPCI. © The Author(s) 2014.
Non-ionic iodinated contrast media related immediate reactions: A mechanism study of 27 patients.
Zhai, Liqin; Guo, Xiangjie; Zhang, Haoyue; Jin, Qianqian; Zeng, Qiang; Tang, Xiaoxian; Gao, Cairong
2017-01-01
The underlying mechanism of non-ionic iodinated contrast media-related immediate reactions was evaluated in this study. Patients presenting at least grade II immediate reactions after non-ionic iodinated contrast media injection were enrolled. Basophil activation was evaluated by flow cytometry. The plasma concentration of human terminal complement complex SC5b-9, as well as concentrations of serum chymase, tryptase, human mast cell carboxypeptidase A3, human prostaglandin D2, and total IgE were measured by enzyme-linked immunosorbent assay. The basophil activation percentage was significantly higher in the study group than in the control group (17.94±21.06% vs 3.45±1.49%). The plasma concentration of human terminal complement complex SC5b-9 and concentrations of serum chymase, human mast cell carboxypeptidase A3, prostaglandin D2, tryptase, and total IgE were also significantly increased (236.99±318.21 vs 49.70±30.41ng/mL, 0.41±0.49 vs 0.09±0.06ng/mL, 1.17±0.67 vs 0.30±0.17ng/mL, 203.52±137.27 vs 102.28±48.72pg/mL, 3.81±0.22 vs 2.70±0.16ng/mL, 102.00±51.84 vs 19.97±2.75ng/mL, respectively). Both mast cells and basophils were activated in non-ionic iodinated contrast media to mediate immediate hypersensitivity, and mast cells may be involved. Different mechanisms, including IgE-dependent, complement-dependent, and direct membrane effects, contributed to mast cell and basophil activation. Individual patients may use a single or combined mechanism involving single or combined mast cells and basophils. Immediate reactions following non-ionic iodinated contrast media injection may be a mechanically heterogenous disease. Copyright © 2016. Published by Elsevier B.V.
Priming International Affairs: How the Media Influence Attitudes toward Foreign Countries.
ERIC Educational Resources Information Center
Willnat, Lars; Graf, Joseph; Brewer, Paul R.
This study broadens the scope of priming research by testing whether media coverage of international affairs shapes the criteria which people use to judge foreign countries. In contrast to previous priming experiments that focused on the effects of television news stories, this study experimentally tests the power of print media to produce priming…
A reference standard-based quality assurance program for radiology.
Liu, Patrick T; Johnson, C Daniel; Miranda, Rafael; Patel, Maitray D; Phillips, Carrie J
2010-01-01
The authors have developed a comprehensive radiology quality assurance (QA) program that evaluates radiology interpretations and procedures by comparing them with reference standards. Performance metrics are calculated and then compared with benchmarks or goals on the basis of published multicenter data and meta-analyses. Additional workload for physicians is kept to a minimum by having trained allied health staff members perform the comparisons of radiology reports with the reference standards. The performance metrics tracked by the QA program include the accuracy of CT colonography for detecting polyps, the false-negative rate for mammographic detection of breast cancer, the accuracy of CT angiography detection of coronary artery stenosis, the accuracy of meniscal tear detection on MRI, the accuracy of carotid artery stenosis detection on MR angiography, the accuracy of parathyroid adenoma detection by parathyroid scintigraphy, the success rate for obtaining cortical tissue on ultrasound-guided core biopsies of pelvic renal transplants, and the technical success rate for peripheral arterial angioplasty procedures. In contrast with peer-review programs, this reference standard-based QA program minimizes the possibilities of reviewer bias and erroneous second reviewer interpretations. The more objective assessment of performance afforded by the QA program will provide data that can easily be used for education and management conferences, research projects, and multicenter evaluations. Additionally, such performance data could be used by radiology departments to demonstrate their value over nonradiology competitors to referring clinicians, hospitals, patients, and third-party payers. Copyright 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Liver imaging with ferumoxides (Feridex): fundamentals, controversies, and practical aspects.
Clément, O; Siauve, N; Cuénod, C A; Frija, G
1998-06-01
Superparamagnetic nanoparticles (Feridex) have been recently made available to the radiological community as a contrast agent for MR imaging of the liver. This article reviews the principal physicochemical characteristics of this new compound, with an emphasis on the explanation of the contrast obtained (either positive or negative enhancement) that depends on the local concentration and the sequence used. The clinical use of Feridex is detailed, both for lesion detection and characterization. Finally, some guidelines for image optimization are given.
NASA Astrophysics Data System (ADS)
Mulyadin; Dewang, Syamsir; Abdullah, Bualkar; Tahir, Dahlang
2018-03-01
In this study, the image quality of CT scan using phantom American College of Radiology (ACR) was determined. Scanning multidetector CT is used to know the image quality parameters by using a solid phantom containing four modules and primarily from materials that are equivalent to water. Each module is 4 cm in diameter and 20 cm in diameter. There is white alignment marks painted white to reflect the alignment laser and there are also “HEAD”, “FOOT”, and “TOP” marks on the phantom to help align. This test obtains CT images of each module according to the routine inspection protocol of the head. Acceptance of image quality obtained for determination: CT Number Accuracy (CTN), CT Number Uniformity and Noise, Linearity CT Number, Slice Technique, Low Contrast Resolution and High Contrast Resolution represent image quality parameters. In testing CT Number Accuracy (CTN), CT Uniform number and Noise are in the range of tolerable values allowed. In the test, Linearity CT Number obtained correlation value above 0.99 is the relationship between electron density and CT Number. In a low contrast resolution test, the smallest contrast groups are visible. In contrast, the high resolution is seen up to 7 lp/cm. The quality of GE CT Scan is very high, as all the image quality tests obtained are within the tolerance brackets of values permitted by the Nuclear Power Control Agency (BAPETEN). Image quality test is a way to get very important information about the accuracy of snoring result by using phantom ACR.
Denardo, Scott J; Vock, David M; Schmalfuss, Carsten M; Young, Gregory D; Tcheng, James E; O'Connor, Christopher M
2016-07-01
Contrast media administered during cardiac catheterization can affect hemodynamic variables. However, little is documented about the effects of contrast on hemodynamics in heart failure patients or the prognostic value of baseline and changes in hemodynamics for predicting subsequent adverse events. In this prospective study of 150 heart failure patients, we measured hemodynamics at baseline and after administration of iodixanol or iopamidol contrast. One-year Kaplan-Meier estimates of adverse event-free survival (death, heart failure hospitalization, and rehospitalization) were generated, grouping patients by baseline measures of pulmonary capillary wedge pressure (PCWP) and cardiac index (CI), and by changes in those measures after contrast administration. We used Cox proportional hazards modeling to assess sequentially adding baseline PCWP and change in CI to 5 validated risk models (Seattle Heart Failure Score, ESCAPE [Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness], CHARM [Candesartan in Heart Failure: Assessment of Reduction in Mortality and Morbidity], CORONA [Controlled Rosuvastatin Multinational Trial in Heart Failure], and MAGGIC [Meta-Analysis Global Group in Chronic Heart Failure]). Median contrast volume was 109 mL. Both contrast media caused similarly small but statistically significant changes in most hemodynamic variables. There were 39 adverse events (26.0%). Adverse event rates increased using the composite metric of baseline PCWP and change in CI (P<0.01); elevated baseline PCWP and decreased CI after contrast correlated with the poorest prognosis. Adding both baseline PCWP and change in CI to the 5 risk models universally improved their predictive value (P≤0.02). In heart failure patients, the administration of contrast causes small but significant changes in hemodynamics. Calculating baseline PCWP with change in CI after contrast predicts adverse events and increases the predictive value of existing models. Patients with elevated baseline PCWP and decreased CI after contrast merit greatest concern. © 2016 American Heart Association, Inc.
Dimonte, Mariano
2008-03-01
Aim of this paper is to offer some cue of reflection about some sociological aspects on the emergent phenomenon of the abuse of Imaging tests, interpreting this issue in the light of general dynamics crossing the actual post-modern society, so well characterized from the consumerism and the dominion of information and communication technologies, as vectors of messages mainly transmitted in a graphic format.
NASA Astrophysics Data System (ADS)
Taravati, Sajjad
2018-06-01
This article presents a class of space-time-varying media with giant linear nonreciprocity, zero space-time local reflections, and zero photonic band gap. This is achieved via equilibrium in the electric and magnetic properties of unidirectionally space-time-modulated media. The enhanced nonreciprocity is accompanied by a larger sonic regime interval which provides extra design freedom for achieving strong nonreciprocity by a weak pumping strength. We show that the width of photonic band gaps in general periodic space-time permittivity- and permeability-modulated media is proportional to the absolute difference between the electric and magnetic pumping strengths. We derive a rigorous analytical solution for investigation of wave propagation and scattering from general periodic space-time permittivity- and permeability-modulated media. In contrast with weak photonic transitions, from the excited mode to its two adjacent modes, in conventional space-time permittivity-modulated media, in an equilibrated space-time-varying medium, strong photonic transitions occur from the excited mode to its four adjacent modes. We study the enhanced nonreciprocity and zero band gap in equilibrated space-time-modulated media by analysis of their dispersion diagrams. In contrast to conventional space-time permittivity-modulated media, equilibrated space-time media exhibit different phase and group velocities for forward and backward harmonics. Furthermore, the numerical simulation scheme of general space-time permittivity- and permeability-modulated media is presented, which is based on the finite-difference time-domain technique. Our analytical and numerical results provide insights into general space-time refractive-index-modulated media, paving the way toward optimal isolators, nonreciprocal integrated systems, and subharmonic frequency generators.
Three-Dimensional Imaging and Quantification of Biomass and Biofilms in Porous Media
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dorthe Wildenschild
2012-10-10
A new method to resolve biofilms in three dimensions in porous media using high-resolution synchrotron-based x-ray computed microtomography (CMT) has been developed. Imaging biofilms in porous media without disturbing the natural spatial arrangement of the porous media and associated biofilm has been a challenging task, primarily because porous media generally precludes conventional imaging via optical microscopy; x-ray tomography offers a potential alternative. One challenge for using this method is that most conventional x-ray contrast agents are water-soluble and easily diffuse into biofilms. To overcome this problem, silver-coated microspheres were added to the fluid phase to create an x-ray contrast thatmore » does not diffuse into the biofilm mass. Using this approach, biofilm imaging in porous media was accomplished with sufficient contrast to differentiate between the biomass- and fluid-filled pore spaces. The method was validated by using a two-dimensional micro-model flow cell where both light microscopy and CMT imaging were used to im age the biofilm. The results of this work has been published in Water Resources Research (Iltis et al., 2010). Additional work needs to be done to optimize this imaging approach, specifically, we find that the quality of the images are highly dependent on the coverage of the biofilm with Ag particles, - which means that we may have issues in dead-end pore space and for very low density (fluffy) biofilms. What we can image for certain with this technique is the biofilm surface that is well-connected to flow paths and thus well-supplied with nutrients etc.« less
The Media Response to the ACGME's 2017 Relaxed Resident Duty-Hour Restrictions.
Zhang, Zi; Krauthamer, Alan V; Rosenkrantz, Andrew B
2018-03-01
In March 2017, the ACGME relaxed resident duty-hour restrictions to allow first-year residents to work 24-hour shifts, affecting the internship experience of incoming radiology residents. The aim of this study was to assess the media response to this duty-hour change, comparing news articles with favorable and unfavorable views. Google News was used to identify 36 relevant unique news articles published over a 4-week period after the announcement. Articles' stance was categorized as favorable, unfavorable, or neutral. Additional article characteristics were explored. Article sources were 58% national, 22% local, and 20% medical news. Article stance was most commonly unfavorable for national news sources (48%), compared with neutral for local (62%) and medical (72%) news sources. Most common reasons for unfavorable stance were sleep deprivation (n = 11), medical errors (n = 11), residents' health (n = 9), risk for car accidents (n = 9), a patriarchal hazing system (n = 6), and work-life balance (n = 5). Most common reasons for favorable stance were impact on resident education (n = 7) and continuity of care (n = 7). Supporting data were cited by 38% of unfavorable and 100% of favorable articles. Unfavorable articles most commonly quoted physicians affiliated with resident advocacy groups; favorable articles most commonly quoted physicians affiliated with the ACGME. The relaxed duty-hour restrictions received an overall unfavorable media response, particularly in nonmedical news sources, driven by concerns regarding sleep-deprived doctors. Favorable articles ubiquitously cited data supporting the safety of relaxed duty hour restrictions. Further research is warranted to better understand the impact of relaxed resident duty-hour limits on sleep deprivation, residents' health and education, and the quality of patient care. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Contrast Medium-Induced Acute Kidney Injury
Sadat, Umar; Usman, Ammara; Boyle, Jonathan R.; Hayes, Paul D.; Solomon, Richard J.
2015-01-01
Contrast medium-induced acute kidney injury (CI-AKI) is a predominant cause of hospital-acquired renal insufficiency. With an increasing number of contrast medium-enhanced radiological procedures being performed in a rapidly increasing ageing population in the Western world, it is imperative that more attention is given to understand the aetiology of CI-AKI to devise novel diagnostic methods and to formulate effective prophylactic and therapeutic regimens to reduce its incidence and its associated morbidity and mortality. This article presents high-yield information on the above-mentioned aspects of CI-AKI, primarily based on results of randomised controlled trials, meta-analyses, systematic reviews and international consensus guidelines. PMID:26195974
Fahrbach, Florian O; Rohrbach, Alexander
2012-01-17
Laser beams that can self-reconstruct their initial beam profile even in the presence of massive phase perturbations are able to propagate deeper into inhomogeneous media. This ability has crucial advantages for light sheet-based microscopy in thick media, such as cell clusters, embryos, skin or brain tissue or plants, as well as scattering synthetic materials. A ring system around the central intensity maximum of a Bessel beam enables its self-reconstruction, but at the same time illuminates out-of-focus regions and deteriorates image contrast. Here we present a detection method that minimizes the negative effect of the ring system. The beam's propagation stability along one straight line enables the use of a confocal line principle, resulting in a significant increase in image contrast. The axial resolution could be improved by nearly 100% relative to the standard light-sheet techniques using scanned Gaussian beams, while demonstrating self-reconstruction also for high propagation depths.
Ultrasound-guided shoulder MR arthrography: comparison of rotator interval and posterior approach.
Ogul, Hayri; Bayraktutan, Ummugulsum; Ozgokce, Mesut; Tuncer, Kutsi; Yuce, Ihsan; Yalcin, Ahmet; Pirimoglu, Berhan; Sagsoz, Erdem; Kantarci, Mecit
2014-01-01
The purpose of this study was to prospectively evaluate the two different ultrasound-guided injection techniques for magnetic resonance (MR) arthrography of the shoulder. This study included 100 patients [50 rotator interval group (n=50) vs. 50 posterior approach group (n=50)]. All procedures were performed by the same radiologist. The two injection techniques were compared. The discomfort during and after arthrography was evaluated. Extraarticular contrast media extravasation was graded according to the MRI findings. The number of injection attempts, effect of contrast media extravasation rate on diagnostic quality and procedure times were recorded. There were no significant difference between the posterior and rotator interval puncture groups with regard to pain (P=.915), procedure times (P=.401) or attempt scores (P=.182). There were significantly more contrast media extravasations with rotator interval approach than posterior approach (P<.05). Both techniques were successful and well tolerated by patients. Posterior injection technique provided a more effective route with decreased extravasation rate and easier approach compared to the rotator interval approach. © 2014.
[Preoperative imaging/operation planning for liver surgery].
Schoening, W N; Denecke, T; Neumann, U P
2015-12-01
The currently established standard for planning liver surgery is multistage contrast media-enhanced multidetector computed tomography (CM-CT), which as a rule enables an appropriate resection planning, e.g. a precise identification and localization of primary and secondary liver tumors as well as the anatomical relation to extrahepatic and/or intrahepatic vascular and biliary structures. Furthermore, CM-CT enables the measurement of tumor volume, total liver volume and residual liver volume after resection. Under the condition of normal liver function a residual liver volume of 25 % is nowadays considered sufficient and safe. Recent studies in patients with liver metastases of colorectal cancer showed a clear staging advantage of contrast media-enhanced magnetic resonance imaging (CM-MRI) versus CM-CT. In addition, most recent data showed that the use of liver-specific MRI contrast media further increases the sensitivity and specificity of detection of liver metastases. This imaging technology seems to lead closer to the ideal "one stop shopping" diagnostic tool in preoperative planning of liver resection.
Radiographic contrast media conservation systems.
1996-11-01
During procedures (such as cardiac catheterizations) that use contrast media, or dyes, large amounts of unused dye can become contaminated with the patient's blood and must be thrown out. Radiographic contrast media conservation systems (RCMCSs) are administration sets designed to reduce the waste of these expensive dyes by (1) isolating the bags or bottles supplying the dyes from contamination, allowing the remaining contents to be used again on another patient, and (2) minimizing the amount of dye left in the administration set (and therefore discarded) at the end of the procedure. In this Evaluation, we examined five burette RCMCSs from three suppliers. We tested the systems for their ability to protect the source containers from contamination, for their performance and design features, and for their ease of use. We also provide information on transfer line assembly RCMCSs, which perform some of the same functions but without using a burette, in a supplementary article within this Evaluation. In addition, a brief Purchasing Guide provides recommendations on deciding whether to purchase RCMCSs and how to choose among systems.
The Fairy-Folk Tale in Media Art: Reflections of Disney and Duvall.
ERIC Educational Resources Information Center
Molloy, Toni
1988-01-01
Focuses on Walt Disney and Shelley Duvall, mass media producers who furnish children with fairy-folklore. Compares and contrasts what Disney and Duvall do and do not convey through their fairy-folk tales. (MS)
Suntharalingam, Saravanabavaan; Mikat, Christian; Stenzel, Elena; Erfanian, Youssef; Wetter, Axel; Schlosser, Thomas; Forsting, Michael; Nassenstein, Kai
2017-01-01
To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different protocols (n = 50 each, group A: 80 kVp, ref. mAs 115, 25 ml of contrast medium; group B: 100 kVp, ref. mAs 150, 60 ml of contrast medium) using a dual-source CT equipped with automated exposure control. Objective and subjective image qualities, radiation exposure as well as the frequency of pulmonary embolism were evaluated. There was no significant difference in subjective image quality scores between two groups regarding pulmonary arteries (p = 0.776), whereby the interobserver agreement was excellent (group A: k = 0.9; group B k = 1.0). Objective image analysis revealed that signal intensities (SI), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the pulmonary arteries were equal or significantly higher in group B. There was no significant difference in the frequency of pulmonary embolism (p = 0.65). Using the low dose and low contrast media protocol resulted in a radiation dose reduction by 71.8% (2.4 vs. 0.7 mSv; p<0.001). This 80 kVp standard pitch CTPA protocol with 25 ml contrast agent volume can obtain sufficient image quality to exclude or diagnose pulmonary emboli while reducing radiation dose by approximately 71%.
Kovindha, A; Sivasomboon, C; Ovatakanont, P
2005-07-01
To present complications and pitfalls in voiding cystourethrography (VCUG) and introduce a guideline for performing VCUG in a long-term spinal cord injury (SCI) patient with neurogenic bladder dysfunction (NBD) and contracted bladder. A case report. Maharaj Nakorn Chiang Mai Hospital, Chiang Mai, Thailand. We describe a chronic C(5) tetraplegic man with NBD and contracted bladder, who developed autonomic dysreflexia (AD), gross hematuria and extravasation of contrast median during VCUG. A foley catheter was retained after VCUG. AD was resolved and urine cleared after a week of continuous bladder irrigation. VCUG should be performed with caution in a long-term SCI patient with NBD and contracted bladder. Forceful pushing of the contrast media by the hand-injection method caused abrupt distention of the contracted bladder, damaged bladder mucosa and aggrevated AD. We suggest a guideline as follows: report bladder capacity and AD, if present, in an X-ray requisition form; use the gravity-drip method, stop the drip and drain the contrast media if a sudden headache and rising of blood pressure (BP) develop; observe urine colour, and report if bleeding or AD occurs.
Wang, Chunrui; Ma, Shuai; Deng, Bo; Lu, Jianxin; Shen, Wei; Jin, Bo; Shi, Haiming; Ding, Feng
2017-11-01
Preexisting renal impairment and the amount of contrast media are the most important risk factors for contrast-induced acute kidney injury (CI-AKI). We aimed to investigate whether the product of contrast medium volume and urinary albumin/creatinine ratio (CMV × UACR) would be a better predictor of CI-AKI in patients undergoing nonemergency coronary interventions. This was a prospective single-center observational study, and 912 consecutive patients who were exposed to contrast media during coronary interventions were investigated prospectively. CI-AKI is defined as a 44.2 μmol/L rise in serum creatinine or a 25% increase, assessed within 48 h after administration of contrast media in the absence of other causes. Fifty patients (5.48%) developed CI-AKI. The urinary albumin/creatinine ratio (UACR) (OR = 1.002, 95% CI = 1.000-1.003, p = .012) and contrast medium volume (CMV) (OR = 1.008, 95% CI = 1.001-1.014, p = .017) were independent risk factors for the development of CI-AKI. The area under the ROC curve of CMV, UACR and CMV × UACR were 0.662 (95% CI = 0.584-0.741, p < .001), 0.761 (95% CI = 0.674-0.847, p < .001) and 0.808 (95% CI = 0.747-0.896, p < .001), respectively. The cutoff value of CMV × UACR to predict CI-AKI was 1186.2, with 80.0% sensitivity and 62.2% specificity. The product of CMV and UACR (CMV × UACR) might be a predictor of CI-AKI in patients undergoing nonemergency coronary interventions, which was superior to CMV or UACR alone.
ERIC Educational Resources Information Center
Daniels, Elizabeth A.
2009-01-01
In contrast to the large body of research examining the negative effects of idealized media images on girls' and women's body image, little research has investigated whether media images can positively impact body concept among females. Using a between-participants experimental design, this study examined how images of performance athletes,…
Valls-Cantenys, Carme; Scheurer, Marco; Iglesias, Mònica; Sacher, Frank; Brauch, Heinz-Jürgen; Salvadó, Victoria
2016-09-01
A sensitive, multi-residue method using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed to determine a representative group of 35 analytes, including corrosion inhibitors, pesticides and pharmaceuticals such as analgesic and anti-inflammatory drugs, five iodinated contrast media, β-blockers and some of their metabolites and transformation products in water samples. Few other methods are capable of determining such a broad range of contrast media together with other analytes. We studied the parameters affecting the extraction of the target analytes, including sorbent selection and extraction conditions, their chromatographic separation (mobile phase composition and column) and detection conditions using two ionisation sources: electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI). In order to correct matrix effects, a total of 20 surrogate/internal standards were used. ESI was found to have better sensitivity than APCI. Recoveries ranging from 79 to 134 % for tap water and 66 to 144 % for surface water were obtained. Intra-day precision, calculated as relative standard deviation, was below 34 % for tap water and below 21 % for surface water, groundwater and effluent wastewater. Method quantification limits (MQL) were in the low ng L(-1) range, except for the contrast agents iomeprol, amidotrizoic acid and iohexol (22, 25.5 and 17.9 ng L(-1), respectively). Finally, the method was applied to the analysis of 56 real water samples as part of the validation procedure. All of the compounds were detected in at least some of the water samples analysed. Graphical Abstract Multi-residue method for the determination of micropollutants including pharmaceuticals, iodinated contrast media and pesticides in waters by LC-MS/MS.
Abnormal gel flotation caused by contrast media during adrenal vein sampling
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Gelati, Matteo; Bassi, Antonella; Contro, Alberto; Pizzolo, Francesca; Guidi, Gian Cesare
2016-01-01
Introduction During adrenal venous sampling (AVS) procedure, radiologists administer a contrast agent via the catheter to visualize the proper catheter position. Materials and methods A patient with primary aldosteronism diagnostic-hypothesis was admitted for AVS. A venogram was performed to confirm the catheter’s position with 2mL of Iopamidol 300 mg/mL. Samples were collected with syringe connected to a hydrophilic coated catheter by low-pressure aspiration from each of the four collection sites: inferior vena cava in the suprarenal portion, inferior vena cava in the infrarenal portion, left adrenal vein, and right adrenal vein; then immediately transferred from syringe to tubes with gel separator. All tubes were centrifuged at 1200 x g for 10 minutes. Results At the end of centrifugation process, primary blood tubes containing blood from inferior vena cava and left adrenal vein exhibited the standard gel separator barrier, while tubes from right adrenal vein showed abnormal flotation of gel separator. The radiologist confirmed the usage of 2.6 mL instead of 2.0 mL of Iopamidol 300 mg/mL. This iodinated contrast media, with 1.33 g/cm3 of density, was used close to the right adrenal vein due to some difficulty to access it. Conclusion The abnormal flotation of gel separator in samples taken from right adrenal vein can be explained by the usage of the iodinated contrast media. We suggest using plain-tubes (without gel separator) for AVS in order to avoid preanalytical nonconformities. Moreover, a blood volume equivalent to twice the catheter extension should be discarded to eliminate residual contrast media before collection of samples for laboratory assays. PMID:27812311
Detectability of radiological images: the influence of anatomical noise
NASA Astrophysics Data System (ADS)
Bochud, Francois O.; Verdun, Francis R.; Hessler, Christian; Valley, Jean-Francois
1995-04-01
Radiological image quality can be objectively quantified by the statistical decision theory. This theory is commonly applied with the noise of the imaging system alone (quantum, screen and film noises) whereas the actual noise present on the image is the 'anatomical noise' (sum of the system noise and the anatomical texture). This anatomical texture should play a role in the detection task. This paper compares these two kinds of noises by performing 2AFC experiments and computing the area under the ROC-curve. It is shown that the 'anatomical noise' cannot be considered as a noise in the sense of Wiener spectrum approach and that the detectability performance is the same as the one obtained with the system noise alone in the case of a small object to be detected. Furthermore, the statistical decision theory and the non- prewhitening observer does not match the experimental results. This is especially the case in the low contrast values for which the theory predicts an increase of the detectability as soon as the contrast is different from zero whereas the experimental result demonstrates an offset of the contrast value below which the detectability is purely random. The theory therefore needs to be improved in order to take this result into account.
Rimawi, Bassam H; Green, Victoria; Lindsay, Michael
2016-06-01
The purpose of this article is to review the fetal and long-term implications of diagnostic radiation exposure during pregnancy. Evidence-based recommendations for radiologic imaging modalities utilizing exposure of diagnostic radiation during pregnancy, including conventional screen-film mammography, digital mammography, tomosynthesis, and contrast-enhanced mammography are described.
Effect of Contrast Media on Single Shot EPI: Implications for Abdominal Diffusion Imaging
Gulani, Vikas; Willatt, Jonathan M.; Blaimer, Martin; Hussain, Hero K.; Duerk, Jeffrey L.; Griswold, Mark A.
2010-01-01
Purpose The goal of this study was to determine the effect of contrast media on the signal behavior of single shot echo planar imaging (ssEPI) used for abdominal diffusion imaging. Materials and Methods The signal of a ssEPI spin echo sequence in a water phantom with varying concentrations of gadolinium was modeled with Bloch equations and the predicted behavior validated on a phantom at 1.5 T. Six volunteers were given gadolinium contrast, and signal intensity (SI) time courses for regions of interest (ROIs) in the liver, pancreas, spleen, renal cortex and medulla were analyzed. The Student's t-test was used to compare pre-contrast SI to 0, 1, 4, 5, 10, and 13 minutes following contrast. Results The results show that following contrast, ssEPI SI goes through a nadir, recovering differently for each organ. Maximal contrast related signal losses relative to pre-contrast signal are 20%, 20%, 53%, and 67%, for the liver, pancreas, renal cortex and medulla respectively. The SIs remain statistically below the pre-contrast values for 5, 4, and 1 minutes for the pancreas, liver, and spleen, and for all times measured for the renal cortex and medulla. Conclusion Abdominal diffusion imaging should be performed prior to contrast due to adverse effects on the signal in ssEPI. PMID:19856456
Hwang, Inpyeong; Cho, Jeong Yeon; Kim, Sang Youn; Oh, Seung-June; Ku, Ja Hyeon; Lee, Joongyup; Kim, Seung Hyup
2015-12-01
The aim of the present study was to investigate the feasibility and image quality of excretory CT urography performed using low iodine-concentration contrast media and low tube voltage. This prospective study enrolled 63 patients who undergoing CT urography. The subjects were randomized into two groups of an excretory phase CT urography protocol and received either 240 mg I/mL of contrast media and 80 kVp of tube voltage (low-concentration protocol, n=32) or 350 mg I/mL and 120 kVp (conventional protocol, n=31). Two readers qualitatively evaluated images for sharpness of the urinary tract, image noise, streak artifact and overall diagnostic acceptability. The mean attenuation, signal-to-noise ratio, contrast-to-noise ratio and figure of merit were measured in the urinary tract. The non-inferiority test assessed the diagnostic acceptability between the two protocol groups. The low-concentration protocol showed a significantly lower effective radiation dose (3.44 vs. 5.70 mSv, P<.001). The diagnostic acceptability was significantly lower in the low-concentration protocol with iterative reconstruction algorithm than in the conventional protocol (4.06±0.45 vs. 4.50±0.37, P<.001), however, all subjects showed at least more than standard diagnostic acceptability and the difference resided in the predefined non-inferiority margin. The signal-to-noise ratio, contrast-to-noise ratio and figure of merit were significantly higher in the low-concentration protocol along the entire urinary tract (P<.001). CT urography using 240 mg I/mL iodine contrast media, 80 kVp tube voltage and an iterative reconstruction algorithm is beneficial to reduce radiation dose and iodine load, and its objective image quality and subjective diagnostic acceptability is not inferior to that of conventional CT urography. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Low contrast media volume in pre-TAVI CT examinations.
Kok, Madeleine; Turek, Jakub; Mihl, Casper; Reinartz, Sebastian D; Gohmann, Robin F; Nijssen, Estelle C; Kats, Suzanne; van Ommen, Vincent G; Kietselaer, Bas L J H; Wildberger, Joachim E; Das, Marco
2016-08-01
To evaluate image quality using reduced contrast media (CM) volume in pre-TAVI assessment. Forty-seven consecutive patients referred for pre-TAVI examination were evaluated. Patients were divided into two groups: group 1 BMI < 28 kg/m(2) (n = 29); and group 2 BMI > 28 kg/m(2) (n = 18). Patients received a combined scan protocol: retrospective ECG-gated helical CTA of the aortic root (80kVp) followed by a high-pitch spiral CTA (group 1: 70 kV; group 2: 80 kVp) from aortic arch to femoral arteries. All patients received one bolus of CM (300 mgI/ml): group 1: volume = 40 ml; flow rate = 3 ml/s, group 2: volume = 53 ml; flow rate = 4 ml/s. Attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the levels of the aortic root (helical) and peripheral arteries (high-pitch). Diagnostic image quality was considered sufficient at attenuation values > 250HU and CNR > 10. Diagnostic image quality for TAVI measurements was obtained in 46 patients. Mean attenuation values and CNR (HU ± SD) at the aortic root (helical) were: group 1: 381 ± 65HU and 13 ± 8; group 2: 442 ± 68HU and 10 ± 5. At the peripheral arteries (high-pitch), mean values were: group 1: 430 ± 117HU and 11 ± 6; group 2: 389 ± 102HU and 13 ± 6. CM volume can be substantially reduced using low kVp protocols, while maintaining sufficient image quality for the evaluation of aortic root and peripheral access sites. • Image quality could be maintained using low kVp scan protocols. • Low kVp protocols reduce contrast media volume by 34-67 %. • Less contrast media volume lowers the risk of contrast-induced nephropathy.
Assessing potential radiological harm to fukushima recovery workers.
Scott, Bobby R
2011-01-01
A radiological emergency exists at the Fukushima Daiichi (Fukushima I) nuclear power plant in Japan as a result of the March 11, 2011 magnitude 9.0 earthquake and the massive tsunami that arrived later. News media misinformation related to the emergency triggered enormous social fear worldwide of the radioactivity that is being released from damaged fuel rods. The heroic recovery workers are a major concern because they are being exposed to mostly gamma radiation during their work shifts and life-threatening damage to the radiosensitive bone marrow could occur over time. This paper presents a way in which the bone marrow equivalent dose (in millisieverts), as estimated per work shift, could be used along with the hazard function model previously developed for radiological risk assessment to repeatedly check for potential life-threatening harm (hematopoietic system damage) to workers. Three categories of radiation hazard indication are proposed: 1, life-threatening damage unlikely; 2, life-threatening damage possible; 3, life-threatening damage likely. Categories 2 and 3 would be avoided if the whole body effective dose did not exceed the annual effective dose limit of 250 mSv. For down-wind populations, hormetic effects (activated natural protective processes) are much more likely than are deleterious effects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coffey, D. E.
2002-02-28
High Efficiency Particulate Air filtration is an essential component of the containment and ventilation systems supporting the research and development activities at the Oak Ridge National Laboratory. High Efficiency Particulate Air filters range in size from 7.6cm (3 inch) by 10.2 cm (4 inch) cylindrical shape filters to filter array assemblies up to 2.1 m (7 feet) high by 1.5 m (5 feet) wide. Spent filters are grouped by contaminates trapped in the filter media and become one of the components in the respective waste stream. Waste minimization and pollution prevention efforts are applied for both radiological and non-radiological applications.more » Radiological applications include laboratory hoods, glove boxes, and hot cells. High Efficiency Particulate Air filters also are generated from intake or pre-filtering applications, decontamination activities, and asbestos abatement applications. The disposal avenues include sanitary/industrial waste, Resource Conservation and Recovery Act and Toxic Substance Control Act, regulated waste, solid low-level waste, contact handled transuranic, and remote handled transuranic waste. This paper discusses characterization and operational experiences associated with the disposal of the spent filters across multiple applications.« less
Diversity Matters in Academic Radiology: Acknowledging and Addressing Unconscious Bias.
Allen, Brenda J; Garg, Kavita
2016-12-01
To meet challenges related to changing demographics, and to optimize the promise of diversity, radiologists must bridge the gap between numbers of women and historically underrepresented minorities in radiology and radiation oncology as contrasted with other medical specialties. Research reveals multiple ways that women and underrepresented minorities can benefit radiology education, research, and practice. To achieve those benefits, promising practices promote developing and implementing strategies that support diversity as an institutional priority and cultivate shared responsibility among all members to create inclusive learning and workplace environments. Strategies also include providing professional development to empower and equip members to accomplish diversity-related goals. Among topics for professional development about diversity, unconscious bias has shown positive results. Unconscious bias refers to ways humans unknowingly draw upon assumptions about individuals and groups to make decisions about them. Researchers have documented unconscious bias in a variety of contexts and professions, including health care, in which they have studied differential treatment, diagnosis, prescribed care, patient well-being and compliance, physician-patient interactions, clinical decision making, and medical school education. These studies demonstrate unfavorable impacts on members of underrepresented groups and women. Learning about and striving to counteract unconscious bias points to promising practices for increasing the numbers of women and underrepresented minorities in the radiology and radiation oncology workforce. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Gamma-Ray imaging for nuclear security and safety: Towards 3-D gamma-ray vision
NASA Astrophysics Data System (ADS)
Vetter, Kai; Barnowksi, Ross; Haefner, Andrew; Joshi, Tenzing H. Y.; Pavlovsky, Ryan; Quiter, Brian J.
2018-01-01
The development of portable gamma-ray imaging instruments in combination with the recent advances in sensor and related computer vision technologies enable unprecedented capabilities in the detection, localization, and mapping of radiological and nuclear materials in complex environments relevant for nuclear security and safety. Though multi-modal imaging has been established in medicine and biomedical imaging for some time, the potential of multi-modal data fusion for radiological localization and mapping problems in complex indoor and outdoor environments remains to be explored in detail. In contrast to the well-defined settings in medical or biological imaging associated with small field-of-view and well-constrained extension of the radiation field, in many radiological search and mapping scenarios, the radiation fields are not constrained and objects and sources are not necessarily known prior to the measurement. The ability to fuse radiological with contextual or scene data in three dimensions, in analog to radiological and functional imaging with anatomical fusion in medicine, provides new capabilities enhancing image clarity, context, quantitative estimates, and visualization of the data products. We have developed new means to register and fuse gamma-ray imaging with contextual data from portable or moving platforms. These developments enhance detection and mapping capabilities as well as provide unprecedented visualization of complex radiation fields, moving us one step closer to the realization of gamma-ray vision in three dimensions.
An evaluation of the use of oral contrast media in abdominopelvic CT.
Buttigieg, Erica Lauren; Grima, Karen Borg; Cortis, Kelvin; Soler, Sandro Galea; Zarb, Francis
2014-11-01
To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. • Positive oral contrast media are routinely used for abdominopelvic multidetector computed tomography • Experimental study comparing image quality using three different oral contrast materials • Three different oral contrast materials result in comparable CT image quality • Benefits for patients and medical imaging department.
Giuliano, Vincenzo; Giuliano, Concetta; Pinto, Fabio; Scaglione, Mariano
2005-07-01
The purpose of this study is to determine if focused CT examinations of the pelvis, utilizing fixed oral dosage of diatrizoate contrast media, improve overall reader confidence in visualization of the appendix. Five hundred and twenty-five patients referred for, rule out appendicitis, evaluations underwent focused CT examinations of the pelvis following fixed oral dosage of diatrizoate contrast media. A five-point scale was used to assess the effect of contrast enhancement of the distal small bowel, cecum, and appendix on overall reader confidence, and subsequent visualization of the appendix. Bowel preparation was ideal in 504 of 525 (96%) patients. Enhanced supine CT images following oral administration of fixed dosage of diatrizoate had consistently good scores for reader confidence for bowel opacification (4.8+/-0.1, P<0.005) and visualization of the appendix (3.7+/-0.1, P<0.005), at 50 min following oral contrast administration. This method improved visualization of the normal appendix in 446 of 504 (88%) patients, with a specificity of 99%. In a patients meeting CT criteria for appendicitis, 21 of 21 (100%) patients were proven at surgery. The use of fixed oral dosage of diatrizoate contrast media resulted in good overall reader confidence to visualize the appendix and peri-appendiceal area, in addition to high specificity and rapid transit time.
Prabhu, Vinay; Rosenkrantz, Andrew B
2015-07-01
The aim of this study was to evaluate use of the microblogging social network Twitter by academic radiology departments (ARDs) in the United States. Twitter was searched to identify all accounts corresponding with United States ARDs. All original tweets from identified accounts over a recent 3-month period (August to October 2014) were archived. Measures of account activity, as well as tweet and link content, were summarized. Fifteen ARDs (8.2%) had Twitter accounts. Ten (5.5%) had "active" accounts, with ≥1 tweet over the 3-month period. Active accounts averaged 711 ± 925 followers (maximum, 2,885) and 61 ± 93 tweets (maximum, 260) during the period. Among 612 tweets from active accounts, content most commonly related to radiology-related education (138), dissemination of departmental research (102), general departmental or hospital promotional material (62), departmental awards or accomplishments (60), upcoming departmental lectures (59), other hospital-related news (55), medical advice or information for patients (38), local community events or news (29), social media and medicine (27), and new departmental or hospital hires or expansion (19). Eighty percent of tweets (490 of 612) included 315 unique external links. Most frequent categories of link sources were picture-, video-, and music-sharing websites (89); the ARD's website or blog (83); peer-reviewed journal articles (40); the hospital's or university's website (34), the lay press (28), and Facebook (14). Twitter provides ARDs the opportunity to engage their own staff members, the radiology community, the department's hospital, and patients, through a broad array of content. ARDs frequently used Twitter for promotional and educational purposes. Because only a small fraction of ARDs actively use Twitter, more departments are encouraged to take advantage of this emerging communication tool. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Blagoveshchenskaya, N. S.; Puchkov, V. L.
1980-01-01
The vestibulo oculomotor reflex (nystagmus) was recorded by means of electronystagmography in 33 neurosurgical patients in dynamics prior to and after ventriculography. For contrasting the ventricular system a water soluble medium (Conrey, dimer X or Amipak) was used in 18 patients and contrast mixtures of water soluble agents in combination with Myodil emulsion in 15. It was established that after ventriculography with water soluble media the trunk vestibular reactions in all types of nystagmus grew frequently and sharply and the vestibulovegetative reactions increased markedly.
Mielke, Dorothee; Kallenberg, Kai; Hartmann, Marius; Rohde, Veit
2016-05-01
The authors report the case of a 76-year-old man with a spinal dural arteriovenous fistula. The patient suffered from sudden repeated reversible paraplegia after spinal digital subtraction angiography as well as CT angiography. Neurotoxicity of contrast media (CM) is the most probable cause for this repeated short-lasting paraplegia. Intolerance to toxicity of CM to the vulnerable spinal cord is rare, and probably depends on the individual patient. This phenomenon is transient and can occur after both intraarterial and intravenous CM application.
X-ray system simulation software tools for radiology and radiography education.
Kengyelics, Stephen M; Treadgold, Laura A; Davies, Andrew G
2018-02-01
To develop x-ray simulation software tools to support delivery of radiological science education for a range of learning environments and audiences including individual study, lectures, and tutorials. Two software tools were developed; one simulated x-ray production for a simple two dimensional radiographic system geometry comprising an x-ray source, beam filter, test object and detector. The other simulated the acquisition and display of two dimensional radiographic images of complex three dimensional objects using a ray casting algorithm through three dimensional mesh objects. Both tools were intended to be simple to use, produce results accurate enough to be useful for educational purposes, and have an acceptable simulation time on modest computer hardware. The radiographic factors and acquisition geometry could be altered in both tools via their graphical user interfaces. A comparison of radiographic contrast measurements of the simulators to a real system was performed. The contrast output of the simulators had excellent agreement with measured results. The software simulators were deployed to 120 computers on campus. The software tools developed are easy-to-use, clearly demonstrate important x-ray physics and imaging principles, are accessible within a standard University setting and could be used to enhance the teaching of x-ray physics to undergraduate students. Current approaches to teaching x-ray physics in radiological science lack immediacy when linking theory with practice. This method of delivery allows students to engage with the subject in an experiential learning environment. Copyright © 2017. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Falkensammer, Peter; Soegner, Peter I.; zur Nedden, Dieter
2002-05-01
The integration of RIS-PACS systems in radiology units are intended to reduce time consumption in radiology workflow and thus to increase radiologist productivity. Along with the RIS-PACS integration at the University Hospital Innsbruck we analyzed workflow from patient admission to release of final reports before implementation. The follow up study after six months of the implementation is currently in work. In this study we compared chest to skeletal x-ray examinations in 969 patients before the implementation. Drawing the admission-to-release-of-final-report period showed a two-peak diagram with the first peak corresponding to a release of final results on the same day and the second peak to a release on the following day. In the chest x-ray group, 57% were released the same day (mean value 4:02 hours) and 43% the next day (mean value 21:47 hours). Looking at the skeletal x-rays 40% were released the same day (mean value 3:58 hours) and 60% were released the next day (mean value 21:05 hours). Summarizing the results we should say, that the average chest x-ray requires less time than an skeletal x-ray, due to the fact that a greater percentage of reports is released the same day. The most important result is, that the most time consuming workstep is the exchange of data media between radiologist and secretary with at least 5 hours.
Mikat, Christian; Stenzel, Elena; Erfanian, Youssef; Wetter, Axel; Schlosser, Thomas; Forsting, Michael
2017-01-01
Objectives To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. Materials and methods Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different protocols (n = 50 each, group A: 80 kVp, ref. mAs 115, 25 ml of contrast medium; group B: 100 kVp, ref. mAs 150, 60 ml of contrast medium) using a dual-source CT equipped with automated exposure control. Objective and subjective image qualities, radiation exposure as well as the frequency of pulmonary embolism were evaluated. Results There was no significant difference in subjective image quality scores between two groups regarding pulmonary arteries (p = 0.776), whereby the interobserver agreement was excellent (group A: k = 0.9; group B k = 1.0). Objective image analysis revealed that signal intensities (SI), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the pulmonary arteries were equal or significantly higher in group B. There was no significant difference in the frequency of pulmonary embolism (p = 0.65). Using the low dose and low contrast media protocol resulted in a radiation dose reduction by 71.8% (2.4 vs. 0.7 mSv; p<0.001). Conclusions This 80 kVp standard pitch CTPA protocol with 25 ml contrast agent volume can obtain sufficient image quality to exclude or diagnose pulmonary emboli while reducing radiation dose by approximately 71%. PMID:29045463
About Face: From Alliance to Alienation. Blacks and the News Media.
ERIC Educational Resources Information Center
Drummond, William J.
1990-01-01
Contrasts media representation of Blacks in the stirring days of the civil rights movement with the present day focus on drug use, homelessness, and crime. Concludes that this superficial and distorted view is harmful in general, not only to Blacks. (DM)
[Aneurysm in the aorta. Diagnostic confirmation by means of a helicoidal CAT scan].
Lema Garrido, Fernando; Moya Merino, Mariano; Jordán López, Cristóbal
2004-09-01
A helicoidal radiological CAT Scan, which produces reconstructions in varying planes and makes use of an injected contrasting liquid, confirms a diagnosis of an abdominal aorta aneurysm in the shortest time possible, whether this aneurysm is broken or dried, in order to facilitate a patient's treatment to the highest degree.
Radiologic imaging of the renal parenchyma structure and function.
Grenier, Nicolas; Merville, Pierre; Combe, Christian
2016-06-01
Radiologic imaging has the potential to identify several functional and/or structural biomarkers of acute and chronic kidney diseases that are useful diagnostics to guide patient management. A renal ultrasound examination can provide information regarding the gross anatomy and macrostructure of the renal parenchyma, and ultrasound imaging modalities based on Doppler or elastography techniques can provide haemodynamic and structural information, respectively. CT is also able to combine morphological and functional information, but the use of CT is limited due to the required exposure to X-ray irradiation and a risk of contrast-induced nephropathy following intravenous injection of a radio-contrast agent. MRI can be used to identify a wide range of anatomical and physiological parameters at the tissue and even cellular level, such as tissue perfusion, oxygenation, water diffusion, cellular phagocytic activity, tissue stiffness, and level of renal filtration. The ability of MRI to provide valuable information for most of these parameters within a renal context is still in development and requires more clinical experience, harmonization of technical procedures, and an evaluation of reliability and validity on a large scale.
Cardiac radiology: centenary review.
de Roos, Albert; Higgins, Charles B
2014-11-01
During the past century, cardiac imaging technologies have revolutionized the diagnosis and treatment of acquired and congenital heart disease. Many important contributions to the field of cardiac imaging were initially reported in Radiology. The field developed from the early stages of cardiac imaging, including the use of coronary x-ray angiography and roentgen kymography, to nowadays the widely used echocardiographic, nuclear medicine, cardiac computed tomographic (CT), and magnetic resonance (MR) applications. It is surprising how many of these techniques were not recognized for their potential during their early inception. Some techniques were described in the literature but required many years to enter the clinical arena and presently continue to expand in terms of clinical application. The application of various CT and MR contrast agents for the diagnosis of myocardial ischemia is a case in point, as the utility of contrast agents continues to expand the noninvasive characterization of myocardium. The history of cardiac imaging has included a continuous process of advances in our understanding of the anatomy and physiology of the cardiovascular system, along with advances in imaging technology that continue to the present day.
Scheller, Bruno; Speck, Ulrich; Romeike, Bernd; Schmitt, Alexander; Sovak, Milos; Böhm, Michael; Stoll, Hans Peter
2003-08-01
Lipophilic taxanes can be dissolved in contrast media at significantly higher concentration than in saline. As contrast media have occasionally been observed to delineate the contour of coronary arteries for some seconds they may serve as a matrix for an antiproliferative drug aimed at preventing restenosis. The aim of this study was to test a novel taxane-contrast agent formulation for this new approach in the setting of coronary stenting. In cell culture experiments (bovine vascular smooth muscle cells), 60-min incubation with contrast agent-taxane formulations (iopromide-paclitaxel, iopromide-protaxel) induced a significant, concentration-dependent inhibition of vascular smooth muscle cell (VSMC) proliferation over 12 days. Shorter incubation times of 10 and 3 min showed the same efficacy. For in vivo investigation, 16 stents were implanted into the coronary arteries of eight pigs using a 1.3 to 1 overstretch ratio. A control group received iopromide 370 alone while the treatment group was injected with a iopromide-protaxel formulation at a dose of 74 micromol/l, which is far below protaxel levels inducing systemic toxicity. Quantitative angiography and histomorphometry of the stented arteries asserted statistic equality of the baseline parameters between the control and treatment groups. After 28 days, the treatment group showed a marked reduction of the parameters characterizing in-stent restenosis, especially a 34% reduction of the neointimal area. First evidence is provided that using a contrast agent as solvent for a taxane constitutes a new drug delivery mechanism able to inhibit in-stent restenosis in the porcine restenosis model.
A new contrast media for functional MR urography: Gd-MAG3.
Algin, Oktay
2011-07-01
Tc-99m-MAG3 (tubular agent) provides high imaging quality and extraction efficiency; and has become one of the most widely used agent for scintigraphic examinations of urinary system pathologies and renal transplants. Recently, it was reported that functional magnetic resonance urography (FMRU) can be sufficient in detection of urinary tract obstruction, renal artery stenosis, calculation of kidney functions and evaluation of renal transplants. However the pharmacokinetics of magnetic resonance (MR) contrast-media used in FMRU and Tc-99m-MAG3 differs from each other. This may cause discordant results between the FMRU and most of the scintigraphic studies. To our knowledge, there is no contrast-media which is specific for FMRU. A kidney specific contrast material can be developed for FMRU studies as well. MAG3 is a good candidate for this chelation. In conclusion, MR imaging (MRI) will be the most useful and important technique for morphologic-functional evaluation of urinary system. FMRU examinations performed with MAG3 chelated gadolinium can be sufficient for the complete evaluation of urinary tract even in patients with impaired renal functions ("all in one MRI"). MRI has some important advantages including no risk for radiation exposure, high temporal and spatial resolution, no need for nephrotoxic contrast agent; besides being a fast and feasible technique. Gadolinium-containing contrast agents may cause a life-threatening adverse reaction known as nephrogenic systemic fibrosis in patients with severe renal impairment, but Gd-MAG3 may reduce the risk of nephrogenic systemic fibrosis due to its higher extraction capacity and other features. Copyright © 2011 Elsevier Ltd. All rights reserved.
Spatially resolved D-T(2) correlation NMR of porous media.
Zhang, Yan; Blümich, Bernhard
2014-05-01
Within the past decade, 2D Laplace nuclear magnetic resonance (NMR) has been developed to analyze pore geometry and diffusion of fluids in porous media on the micrometer scale. Many objects like rocks and concrete are heterogeneous on the macroscopic scale, and an integral analysis of microscopic properties provides volume-averaged information. Magnetic resonance imaging (MRI) resolves this spatial average on the contrast scale set by the particular MRI technique. Desirable contrast parameters for studies of fluid transport in porous media derive from the pore-size distribution and the pore connectivity. These microscopic parameters are accessed by 1D and 2D Laplace NMR techniques. It is therefore desirable to combine MRI and 2D Laplace NMR to image functional information on fluid transport in porous media. Because 2D Laplace resolved MRI demands excessive measuring time, this study investigates the possibility to restrict the 2D Laplace analysis to the sum signals from low-resolution pixels, which correspond to pixels of similar amplitude in high-resolution images. In this exploratory study spatially resolved D-T2 correlation maps from glass beads and mortar are analyzed. Regions of similar contrast are first identified in high-resolution images to locate corresponding pixels in low-resolution images generated with D-T2 resolved MRI for subsequent pixel summation to improve the signal-to-noise ratio of contrast-specific D-T2 maps. This method is expected to contribute valuable information on correlated sample heterogeneity from the macroscopic and the microscopic scales in various types of porous materials including building materials and rock. Copyright © 2014 Elsevier Inc. All rights reserved.
Pathogenesis of renal failure in multiple myeloma: any role of contrast media?
Mussap, Michele; Merlini, Giampaolo
2014-01-01
The spectrum of kidney disease-associated monoclonal immunoglobulin and plasma cell malignancies is remarkably broad and encompasses nearly all nephropathologic entities. Multiple myeloma with kidney impairment at presentation is a medical emergency since the recovery of kidney function is associated with survival benefits. In most cases, kidney impairment may be the first clinical manifestation of malignant plasma cell dyscrasias like multiple myeloma and light chain amyloidosis. Multiple myeloma per se cannot be considered a main risk factor for developing acute kidney injury following intravascular administration of iodinated contrast media. The risk is increased by comorbidities such as chronic kidney disease, diabetes, hypercalcemia, dehydration, and use of nephrotoxic drugs. Before the administration of contrast media, the current recommended laboratory tests for assessing kidney function are serum creatinine measurement and the estimation of glomerular filtration rate by using the CKD-EPI equation. The assessment of Bence Jones proteinuria is unnecessary for evaluating the risk of kidney failure in patients with multiple myeloma, since this test cannot be considered a surrogate biomarker of kidney function.
Adverse effects of meglumine diatrizoate on renal function in the early post-transplant period.
Light, J A; Perloff, L J; Etheredge, E E; Hill, G; Spees, E K
1975-11-01
Thirty-four renal transplant recipients received drip infusion urograms from 2-24 days post-transplantation. Twenty-two patients exhibited changes in renal function within 1-4 days of the urogram that were indistinguishable from allograft rejection: a tender, swollen kidney, elevation of serum creatinine, oliguria, decreased urine sodium concentration, weight gain, and hypertension. Two patients developed acute tubular necrosis and required hemodialysis, but renal function in the remaining 20 patients improved after therapy for "graft rejection" with i.v. methyprednisolone sodium succinnate. Kidneys from older-age donors that were functioning suboptimally and kidneys which exhibited subsequent clinical allograft rejection were more at risk for contrast media toxicity. This suggests that occult vascular lesions may have been present in the allograft which were exacerbated when exposed to the irritant vascular effects of contrast media, producing a mild, reversible toxic nephritis. However, several kidneys with normal function and several kidneys which never exhibited rejection activity were also adversely affected by exposure to contrast media. It appears these agents should be used cautiously, if at all, in the early post-transplant period.
Pathogenesis of Renal Failure in Multiple Myeloma: Any Role of Contrast Media?
Mussap, Michele; Merlini, Giampaolo
2014-01-01
The spectrum of kidney disease-associated monoclonal immunoglobulin and plasma cell malignancies is remarkably broad and encompasses nearly all nephropathologic entities. Multiple myeloma with kidney impairment at presentation is a medical emergency since the recovery of kidney function is associated with survival benefits. In most cases, kidney impairment may be the first clinical manifestation of malignant plasma cell dyscrasias like multiple myeloma and light chain amyloidosis. Multiple myeloma per se cannot be considered a main risk factor for developing acute kidney injury following intravascular administration of iodinated contrast media. The risk is increased by comorbidities such as chronic kidney disease, diabetes, hypercalcemia, dehydration, and use of nephrotoxic drugs. Before the administration of contrast media, the current recommended laboratory tests for assessing kidney function are serum creatinine measurement and the estimation of glomerular filtration rate by using the CKD-EPI equation. The assessment of Bence Jones proteinuria is unnecessary for evaluating the risk of kidney failure in patients with multiple myeloma, since this test cannot be considered a surrogate biomarker of kidney function. PMID:24877060
Non-squamous cell neoplasms of the larynx: radiologic-pathologic correlation.
Becker, M; Moulin, G; Kurt, A M; Dulgerov, P; Vukanovic, S; Zbären, P; Marchal, F; Rüfenacht, D A; Terrier, F
1998-01-01
A variety of benign and malignant non-squamous cell neoplasms may affect the larynx. Most of these uncommon laryngeal neoplasms are located beneath an intact mucosa, making diagnosis difficult with endoscopy alone, and sampling errors may occur if only traditional superficial biopsies are performed. In some laryngeal neoplasms, radiologic evaluation allows the correct diagnosis. Hemangiomas have very high signal intensity at T2-weighted magnetic resonance (MR) imaging and strong enhancement at both computed tomography (CT) and MR imaging after administration of contrast material. Phleboliths, which are pathognomonic for hemangiomas, are easily identified at CT. Chondrogenic tumors typically manifest with coarse or stippled calcifications at CT. Because of their high water content, chondrogenic tumors have very high signal intensity on T2-weighted MR images, whereas only moderate enhancement is observed after administration of contrast material. Lipomas typically manifest at both CT and MR imaging as homogeneous nonenhancing lesions. They are isoattenuating to subcutaneous fat at CT and isointense relative to subcutaneous fat with all MR pulse sequences. Metastases from renal adenocarcinoma typically demonstrate strong contrast enhancement and flow voids at MR imaging, and metastases from melanotic melanoma usually have high signal intensity on T1-weighted MR images and low signal intensity on T2-weighted images owing to the paramagnetic properties of melanin. Although radiologic findings are nonspecific in most other non-squamous cell neoplasms of the larynx (eg, Kaposi sarcoma, hematopoietic tumors, tumors of the minor salivary glands, metastases from amelanotic melanoma), cross-sectional imaging can play an important role in the diagnostic work-up of these unusual tumors by delineating the extent of submucosal tumor spread and directing the endoscopist to the appropriate site for the deep, transmucosal biopsies needed to establish the diagnosis. In addition, CT and MR imaging are crucial for posttherapeutic monitoring and early detection of local recurrence.
Kulkarni, Sakil; Gomara, Roberto; Reeves-Garcia, Jesse; Hernandez, Erick; Restrepo, Ricardo
2014-02-01
The radiologic healing of perianal fistulizing Crohn disease (PfCD) lags behind the clinical healing. Contrast-enhanced pelvic magnetic resonance imaging (MRI) is the radiologic study of choice used to diagnose PfCD in children. The aim was to study whether the various MRI-based radiologic parameters and score can help in staging and follow-up of patients with PfCD. We performed a retrospective chart review of children with PfCD who underwent contrast-enhanced MRI of the pelvis. The demographic profile, clinical status, and laboratory data of the patients at the time of each MRI examination were noted. Based on the clinical status of the patient at the time of MRI examinations, the MRIs were classified into 3 groups: severe disease, mild-to-moderate disease, and asymptomatic. Each MRI examination was reviewed by a radiologist, who was blinded to the clinical status of the patient. Of the radiologic parameters, the number of fistulas, the complexity of fistulas, and the number of abscesses were significantly lower in the asymptomatic group compared with the mild-to-moderate and severe disease groups. The Van Assche MRI-based score was significantly lower in the asymptomatic group compared with the mild-to-moderate disease (P = 0.01) and the severe disease group (P = 0.002). The percentage increase in fistula activity after gadolinium administration was significantly lower in the asymptomatic group compared with the mild-to-moderate disease (P = 0.026) and severe disease (P = 0.019) groups. The MRI-based scores were significantly higher in the MRI examinations performed at diagnosis compared with those that were performed while the patients were receiving the treatment (P = 0.017). The Van Assche MRI score and the percentage increase in fistula activity after gadolinium administration help in assessing the severity perianal Crohn disease. The Van Assche MRI score may be helpful in documenting healing during therapy of perianal Crohn disease.
Annoni, Andrea Daniele; Mancini, Maria E; Andreini, Daniele; Formenti, Alberto; Mushtaq, Saima; Nobili, Enrica; Guglielmo, Marco; Baggiano, Andrea; Conte, Edoardo; Pepi, Mauro
2017-10-01
Multidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. Two-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100 Kvp tube voltage), Group C (Iomeprol 400 and 80 Kvp tube voltage) and Group D (Iomeprol 400 and 100 Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. No significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80 kV versus groups using 100 kV but without differences in terms of image quality. ED was significantly lower in groups with 80 kV. Multidetector Computed Tomography Angiography protocols using 80 kV and low concentration contrast media are feasible without need of tailored injection protocols. © 2017 The Royal Australian and New Zealand College of Radiologists.
Cheungpasitporn, Wisit; Thongprayoon, Charat; Brabec, Brady A; Edmonds, Peter J; O'Corragain, Oisin A; Erickson, Stephen B
2014-12-01
The reports on efficacy of oral hydration treatment for the prevention of contrast-induced acute kidney injury (CIAKI) in elective radiological procedures and cardiac catheterization remain controversial. The objective of this meta-analysis was to assess the use of oral hydration regimen for prevention of CIAKI. Comprehensive literature searches for randomized controlled trials (RCTs) of outpatient oral hydration treatment was performed using MEDLINE, EMBASE, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials Systematic Reviews, and clinicaltrials.gov from inception until July 4(th), 2014. Primary outcome was the incidence of CIAKI. Six prospective RCTs were included in our analysis. Of 513patients undergoing elective procedures with contrast exposures,45 patients (8.8%) had CIAKI. Of 241 patients with oral hydration regimen, 23 (9.5%) developed CIAKI. Of 272 patients with intravenous (IV) fluid regimen, 22 (8.1%) had CIAKI. Study populations in all included studies had relatively normal kidney function to chronic kidney disease (CKD) stage 3. There was no significant increased risk of CIAKI in oral fluid regimen group compared toIV fluid regimen group (RR = 0.94, 95% confidence interval, CI = 0.38-2.31). According to our analysis,there is no evidence that oral fluid regimen is associated with more risk of CIAKI in patients undergoing elective procedures with contrast exposures compared to IV fluid regimen. This finding suggests that the oral fluid regimen might be considered as a possible outpatient treatment option for CIAKI prevention in patients with normal to moderately reduced kidney function.
Patterns of contrast enhancement in the brain and meninges.
Smirniotopoulos, James G; Murphy, Frances M; Rushing, Elizabeth J; Rees, John H; Schroeder, Jason W
2007-01-01
Contrast material enhancement for cross-sectional imaging has been used since the mid 1970s for computed tomography and the mid 1980s for magnetic resonance imaging. Knowledge of the patterns and mechanisms of contrast enhancement facilitate radiologic differential diagnosis. Brain and spinal cord enhancement is related to both intravascular and extravascular contrast material. Extraaxial enhancing lesions include primary neoplasms (meningioma), granulomatous disease (sarcoid), and metastases (which often manifest as mass lesions). Linear pachymeningeal (dura-arachnoid) enhancement occurs after surgery and with spontaneous intracranial hypotension. Leptomeningeal (pia-arachnoid) enhancement is present in meningitis and meningoencephalitis. Superficial gyral enhancement is seen after reperfusion in cerebral ischemia, during the healing phase of cerebral infarction, and with encephalitis. Nodular subcortical lesions are typical for hematogenous dissemination and may be neoplastic (metastases) or infectious (septic emboli). Deeper lesions may form rings or affect the ventricular margins. Ring enhancement that is smooth and thin is typical of an organizing abscess, whereas thick irregular rings suggest a necrotic neoplasm. Some low-grade neoplasms are "fluid-secreting," and they may form heterogeneously enhancing lesions with an incomplete ring sign as well as the classic "cyst-with-nodule" morphology. Demyelinating lesions, including both classic multiple sclerosis and tumefactive demyelination, may also create an open ring or incomplete ring sign. Thick and irregular periventricular enhancement is typical for primary central nervous system lymphoma. Thin enhancement of the ventricular margin occurs with infectious ependymitis. Understanding the classic patterns of lesion enhancement--and the radiologic-pathologic mechanisms that produce them--can improve image assessment and differential diagnosis.
Women in media in the Philippines: from stereotype to liberation.
Fernandez, D G
1987-01-01
The success of women in the Philippine print and electronic media is contrasted with the negative image in which they are presented in mass media such as television, radio, comics, tabloids and magazines. Philippine women began entering journalism early in the century, becoming established in the female oriented press by the 1960s. As the repression of the Marcos regime intensified, women journalists excelled in writing vanguard pieces, using allusion, allegory, indirection or metaphor, interviewing prisoners, founding alternative newspapers and even initiating the successful boycott of the 3 major crony papers when Aquino was killed. The participation of women in television journalism is parallel, but more limited due to the nature of the medium. Women's cultural role as multi-track organizers of family, finance and work is credited for this success. Dozens of names with titles and paper names are cited, as well as tabulated in an appendix. In contrast, women's image in the popular publications and electronic media is that of sex object, victim, ideal submissive wife-mother, or gracious lady shows little evidence of improving. This deleterious, backward and inaccurate image is likely due to all-male ownership, management and profit motive of these popular, vernacular mass media.
1993-11-01
Despite the emergence of several alternative angiographic imaging techniques (i.e., magnetic resonance imaging, computed tomography, and ultrasound angiography), x-ray angiography remains the predominant vascular imaging modality, generating over $4 billion in revenue a year in U.S. hospitals. In this issue, we provide a brief overview of the various angiographic imaging techniques, comparing them with x-ray angiography, and discuss the clinical aspects of x-ray vascular imaging, including catheterization and clinical applications. Clinical, cost, usage, and legal issues related to contrast media are discussed in "Contrast Media: Ionic versus Nonionic and Low-osmolality Agents." We also provide a technical overview and selection guidance for a basic x-ray angiography imaging system, including the gantry and table system, x-ray generator, x-ray tube, image intensifier, video camera and display monitors, image-recording devices, and digital acquisition and processing systems. This issue also contains our Evaluation of the GE Advantx L/C cardiac angiography system and the GE Advantx AFM general-purpose angiography system; the AFM can be used for peripheral, pulmonary, and cerebral vascular studied, among others, and can also be configured for cardiac angiography. Many features of the Advantx L/C system, including generator characteristics and ease of use, also apply to the Advantx AFM as configured for cardiac angiography. Our ratings are based on the systems' ability to provide the best possible image quality for diagnosis and therapy while minimizing patient and personnel exposure to radiation, as well as its ability to minimize operator effort and inconvenience. Both units are rated Acceptable. In the Guidance Section, "Radiation Safety and Protection," we discuss the importance of keeping patient and personnel exposures to radiation as low as reasonably possible, especially in procedures such as cardiac catheterization, angiographic imaging for special procedures, and interventional radiology, which produce among the highest radiation exposure of all x-ray imaging techniques. We also provide recommendations for minimizing personnel and patient exposures to radiation. For more information about x-ray angiography systems and similar devices, as well as for additional perspectives on which we based this study, see the following Health Devices Evaluations: "Mobile C-arm Units" (19[8], August 1990) and "Noninvasive Electronic Quality Control Devices for X-ray Generator Testing" (21[6-7], June-July 1992).(ABSTRACT TRUNCATED AT 400 WORDS)
Roessler, Ann-Christin; Hupfer, Martin; Kolditz, Daniel; Jost, Gregor; Pietsch, Hubertus; Kalender, Willi A
2016-04-01
Spectral optimization of x-ray computed tomography (CT) has led to substantial radiation dose reduction in contrast-enhanced CT studies using standard iodinated contrast media. The purpose of this study was to analyze the potential for further dose reduction using high-atomic-number elements such as hafnium and tungsten. As in previous studies, spectra were determined for which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) is minimized. We used 2 different quasi-anthropomorphic phantoms representing the liver cross-section of a normal adult and an obese adult patient with the lateral widths of 360 and 460 mm and anterior-posterior heights of 200 and 300 mm, respectively. We simulated and measured on 2 different scanners with x-ray spectra from 80 to 140 kV and from 70 to 150 kV, respectively. We determined the contrast for iodine-, hafnium-, and tungsten-based contrast media, the noise, and 3-dimensional dose distributions at all available tube voltages by measurements and by simulations. The dose-weighted CNR was determined as optimization parameter. Simulations and measurements were in good agreement regarding their dependence on energy for all parameters investigated. Hafnium provided the best performance for normal and for obese patient phantoms, indicating a dose reduction potential of 30% for normal and 50% for obese patients at 120 kV compared with iodine; this advantage increased further with higher kV values. Dose-weighted CNR values for tungsten were always slightly below the hafnium results. Iodine proved to be the superior choice at voltage values of 80 kV and below. Hafnium and tungsten both seem to be candidates for contrast-medium-enhanced CT of normal and obese adult patients with strongly reduced radiation dose at unimpaired image quality. Computed tomography examinations of obese patients will decrease in dose for higher kV values.
Phase-contrast Hounsfield units of fixated and non-fixated soft-tissue samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willner, Marian; Fior, Gabriel; Marschner, Mathias
X-ray phase-contrast imaging is a novel technology that achieves high soft-tissue contrast. Although its clinical impact is still under investigation, the technique may potentially improve clinical diagnostics. In conventional attenuation-based X-ray computed tomography, radiological diagnostics are quantified by Hounsfield units. Corresponding Hounsfield units for phase-contrast imaging have been recently introduced, enabling a setup-independent comparison and standardized interpretation of imaging results. Thus far, the experimental values of few tissue types have been reported; these values have been determined from fixated tissue samples. This study presents phase-contrast Hounsfield units for various types of non-fixated human soft tissues. A large variety of tissuemore » specimens ranging from adipose, muscle and connective tissues to liver, kidney and pancreas tissues were imaged by a grating interferometer with a rotating-anode X-ray tube and a photon-counting detector. In addition, we investigated the effects of formalin fixation on the quantitative phase-contrast imaging results.« less
Phase-Contrast Hounsfield Units of Fixated and Non-Fixated Soft-Tissue Samples
Willner, Marian; Fior, Gabriel; Marschner, Mathias; Birnbacher, Lorenz; Schock, Jonathan; Braun, Christian; Fingerle, Alexander A.; Noël, Peter B.; Rummeny, Ernst J.; Pfeiffer, Franz; Herzen, Julia
2015-01-01
X-ray phase-contrast imaging is a novel technology that achieves high soft-tissue contrast. Although its clinical impact is still under investigation, the technique may potentially improve clinical diagnostics. In conventional attenuation-based X-ray computed tomography, radiological diagnostics are quantified by Hounsfield units. Corresponding Hounsfield units for phase-contrast imaging have been recently introduced, enabling a setup-independent comparison and standardized interpretation of imaging results. Thus far, the experimental values of few tissue types have been reported; these values have been determined from fixated tissue samples. This study presents phase-contrast Hounsfield units for various types of non-fixated human soft tissues. A large variety of tissue specimens ranging from adipose, muscle and connective tissues to liver, kidney and pancreas tissues were imaged by a grating interferometer with a rotating-anode X-ray tube and a photon-counting detector. Furthermore, we investigated the effects of formalin fixation on the quantitative phase-contrast imaging results. PMID:26322638
Phase-contrast Hounsfield units of fixated and non-fixated soft-tissue samples
Willner, Marian; Fior, Gabriel; Marschner, Mathias; ...
2015-08-31
X-ray phase-contrast imaging is a novel technology that achieves high soft-tissue contrast. Although its clinical impact is still under investigation, the technique may potentially improve clinical diagnostics. In conventional attenuation-based X-ray computed tomography, radiological diagnostics are quantified by Hounsfield units. Corresponding Hounsfield units for phase-contrast imaging have been recently introduced, enabling a setup-independent comparison and standardized interpretation of imaging results. Thus far, the experimental values of few tissue types have been reported; these values have been determined from fixated tissue samples. This study presents phase-contrast Hounsfield units for various types of non-fixated human soft tissues. A large variety of tissuemore » specimens ranging from adipose, muscle and connective tissues to liver, kidney and pancreas tissues were imaged by a grating interferometer with a rotating-anode X-ray tube and a photon-counting detector. In addition, we investigated the effects of formalin fixation on the quantitative phase-contrast imaging results.« less
Kretzschmar, Franziska; Pleimling, Dominique; Hosemann, Jana; Füssel, Stephan; Bornkessel-Schlesewsky, Ina; Schlesewsky, Matthias
2013-01-01
In the rapidly changing circumstances of our increasingly digital world, reading is also becoming an increasingly digital experience: electronic books (e-books) are now outselling print books in the United States and the United Kingdom. Nevertheless, many readers still view e-books as less readable than print books. The present study thus used combined EEG and eyetracking measures in order to test whether reading from digital media requires higher cognitive effort than reading conventional books. Young and elderly adults read short texts on three different reading devices: a paper page, an e-reader and a tablet computer and answered comprehension questions about them while their eye movements and EEG were recorded. The results of a debriefing questionnaire replicated previous findings in that participants overwhelmingly chose the paper page over the two electronic devices as their preferred reading medium. Online measures, by contrast, showed shorter mean fixation durations and lower EEG theta band voltage density--known to covary with memory encoding and retrieval--for the older adults when reading from a tablet computer in comparison to the other two devices. Young adults showed comparable fixation durations and theta activity for all three devices. Comprehension accuracy did not differ across the three media for either group. We argue that these results can be explained in terms of the better text discriminability (higher contrast) produced by the backlit display of the tablet computer. Contrast sensitivity decreases with age and degraded contrast conditions lead to longer reading times, thus supporting the conclusion that older readers may benefit particularly from the enhanced contrast of the tablet. Our findings thus indicate that people's subjective evaluation of digital reading media must be dissociated from the cognitive and neural effort expended in online information processing while reading from such devices.
Kretzschmar, Franziska; Pleimling, Dominique; Hosemann, Jana; Füssel, Stephan; Bornkessel-Schlesewsky, Ina; Schlesewsky, Matthias
2013-01-01
In the rapidly changing circumstances of our increasingly digital world, reading is also becoming an increasingly digital experience: electronic books (e-books) are now outselling print books in the United States and the United Kingdom. Nevertheless, many readers still view e-books as less readable than print books. The present study thus used combined EEG and eyetracking measures in order to test whether reading from digital media requires higher cognitive effort than reading conventional books. Young and elderly adults read short texts on three different reading devices: a paper page, an e-reader and a tablet computer and answered comprehension questions about them while their eye movements and EEG were recorded. The results of a debriefing questionnaire replicated previous findings in that participants overwhelmingly chose the paper page over the two electronic devices as their preferred reading medium. Online measures, by contrast, showed shorter mean fixation durations and lower EEG theta band voltage density – known to covary with memory encoding and retrieval – for the older adults when reading from a tablet computer in comparison to the other two devices. Young adults showed comparable fixation durations and theta activity for all three devices. Comprehension accuracy did not differ across the three media for either group. We argue that these results can be explained in terms of the better text discriminability (higher contrast) produced by the backlit display of the tablet computer. Contrast sensitivity decreases with age and degraded contrast conditions lead to longer reading times, thus supporting the conclusion that older readers may benefit particularly from the enhanced contrast of the tablet. Our findings thus indicate that people's subjective evaluation of digital reading media must be dissociated from the cognitive and neural effort expended in online information processing while reading from such devices. PMID:23405265
Image management within a PACS
NASA Astrophysics Data System (ADS)
Glicksman, Robert A.; Prior, Fred W.; Wilson, Dennis L.
1993-09-01
The full benefits of a PACS system cannot be achieved by a departmental system, as films must still be made to service referring physicians and clinics. Therefore, a full hospital PACS must provide workstations throughout the hospital which are connected to the central file server and database, but which present `clinical' views of radiological data. In contrast to the radiologist, the clinician needs to select examinations from a `patient list' which presents the results of his/her radiology referrals. The most important data for the clinician is the radiology report, which must be immediately available upon selection of the examination. The images themselves, perhaps with annotations provided by the reading radiologist, must also be available in a few seconds from selection. Furthermore, the ability to display radiologist selected relevant historical images along with the new examination is necessary in those instances where the radiologist felt that certain historical images were important in the interpretation and diagnosis of the patient. Therefore, views of the new and historical data along clinical lines, conference preparation features, and modality and body part specific selections are also required to successfully implement a full hospital PACS. This paper describes the concepts for image selection and presentation at PACS workstations, both `diagnostic' workstations within the radiology department and `clinical' workstations which support the rest of the hospital and outpatient clinics.
The effects of water and lipids on NIR optical breast measurements
NASA Astrophysics Data System (ADS)
Cerussi, Albert E.; Bevilacqua, Frederic; Shah, Natasha; Jakubowski, Dorota B.; Berger, Andrew J.; Lanning, Ryan M.; Tromberg, Bruce J.
2001-06-01
Near infrared diffuse optical spectroscopy and imaging may enhance existing technologies for breast cancer screening, diagnosis, and treatment. NIR spectroscopy yields quantitative functional information that cannot be obtained with other non-invasive radiological techniques. In this study we focused upon the origins of this contrast in healthy breast, especially from water and lipids.
Investigation of disorders of the anorectum and colon.
Henry, M. M.; Snooks, S. J.; Barnes, P. R.; Swash, M.
1985-01-01
Previously, investigation of disorders of the anorectum and colon have been limited to manometric, external anal sphincter muscle electromyographic and contrast radiological techniques. In this paper we describe other investigative techniques recently developed at St. Mark's Hospital, London and their application in the investigation of certain disorders of the anorectum and colon. Images Fig. 3 PMID:3878123
Dacryocystography using cone beam CT in patients with lacrimal drainage system obstruction.
Tschopp, Markus; Bornstein, Michael M; Sendi, Pedram; Jacobs, Reinhilde; Goldblum, David
2014-01-01
To assess the usefulness of cone beam CT (CBCT) for dacryocystography (DCG) using either direct syringing or passive application of contrast medium. Ten consecutive patients with epiphora who had CBCT-DCG in a sitting position were retrospectively analyzed. CBCT-DCGs were performed using 2 techniques: direct syringing with contrast medium or using the passive technique, where patients received 3 drops of contrast medium into the conjunctival sac before CBCT-DCG. Clinical and radiologic diagnoses were compared for both groups. The 10 patients (men = 3) had a mean age of 63.2 years. Both techniques proved to be simple procedures with good delineation of the bone, soft tissue, and the contrast medium in the lacrimal system. No side effects were noted. CBCT-DCG is a useful alternative to determine the localization of stenosis in patients with chronic epiphora.
Volumetric CT-images improve testing of radiological image interpretation skills.
Ravesloot, Cécile J; van der Schaaf, Marieke F; van Schaik, Jan P J; ten Cate, Olle Th J; van der Gijp, Anouk; Mol, Christian P; Vincken, Koen L
2015-05-01
Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Two groups of medical students (n=139; n=143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students' test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p<.001). The volumetric CT-image testing program was considered user-friendly. This study shows that volumetric image questions can be successfully integrated in students' radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Wilson, W B; Haus, A G; Nierman, C; Lillie, R; Batz, T; Moore, R
1993-01-01
In medical imaging, the temperature of the developer solution in the film processor affects film speed (radiation dose), film contrast, and film base plus fog. The National Council on Radiation Protection and Measurement (NCRP) Report 99 on Quality Assurance, and the American College of Radiology (ACR) Mammography Quality Control Manual for Radiologic Technologists, indicate that the developer temperature should be within +/- 0.5 degree F (+/- 0.3 degree C) of that recommended by the manufacturer for the specific film/developer combination being used. The accuracy and repeatability of the thermometer is most important. This paper describes the requirements of a thermometer for measuring the temperature of the developer solution and suggests an inexpensive but accurate device for doing so.
External ophthalmoplegia with orbital myositis in an adult patient after chickenpox infection.
Kim, Jung-Hoon; Lee, Seung-Jun; Kim, Moosang
2014-05-16
Herpes zoster and chickenpox are caused by a single virus, varicella-zoster virus. Herpes zoster ophthalmicus-associated ophthalmoplegia is well documented. Very rarely, herpes zoster and chickenpox cause external ophthalmoplegia. A 48-year-old man was diagnosed with chickenpox and treated with intravenous acyclovir. He suddenly reported diplopia and restricted left eye movement. MRI of the orbit revealed thickening and abnormal contrast enhancement of the preseptal space and lateral rectus muscle of the left eye. In this case, external ophthalmoplegia occurred following chickenpox with radiological evidence of orbital myositis. To the best of our knowledge, this is the first case report of external ophthalmoplegia of radiologically confirmed orbital myositis after chickenpox infection. 2014 BMJ Publishing Group Ltd.
Isolated Cortical Vein Thrombosis - The Cord Sign
Sharma, Vijay K.; Teoh, Hock L
2009-01-01
Isolated cortical vein thrombosis is an uncommon condition and often difficult to diagnose, both clinically and radiologically. We report a case of a 38 years old man who presented with headache of new onset and clinical examination was unremarkable. The unenhanced brain CT did not reveal any abnormality. In view of unrelenting headache and partial seizures, we performed magnetic resonance imaging (with axial T1, T2 and gradient echo sequences, coronal FLAIR, diffusion weighted imaging as well as Gadolinium contrast-enhanced images) and magnetic resonance venography of the brain that revealed an isolated parietal cortical vein thrombosis with the rarely reported 'cord sign'. We report the clinical and radiological findings in our patient with isolated parietal cortical vein thrombosis. PMID:22470649
Hou, Dailun; Qu, Huifang; Zhang, Xu; Li, Ning; Liu, Cheng; Ma, Xiangxing
2014-09-02
The aim of this study was to determine whether the diagnosis of intracranial tuberculosis (TB) can be improved when multi-slice computed tomography (MSCT) scans are taken with a 5-min delay after contrast media application. Pre- and post-contrast CT scans of the head were obtained from 30 patients using a 16-slice spiral CT. Dual-phase acquisition was performed immediately and 5 min after contrast agent injection. Diagnostic values of different images were compared using a scoring system applied by 2 experienced radiologists. We found 526 lesions in 30 patients, including 22 meningeal thickenings, 235 meningeal tuberculomas/tubercles, and 269 parenchymal tuberculomas/tubercles. Images obtained with 5-min delayed scan time were superior in terms of lesion size and meningeal thickening outlining in all disease types (P<0.01). The ability to distinguish between vascular sections from the cerebral sulcus and tubercle was also improved (P<0.01). Image acquisition with 5-min delay after contrast agent injection should be performed as a standard scanning protocol to diagnose intracranial TB.
Emergency Response Health Physics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mena, RaJah; Pemberton, Wendy; Beal, William
2012-05-01
Health physics is an important discipline with regard to understanding the effects of radiation on human health; however, there are major differences between health physics for research or occupational safety and health physics during a large-scale radiological emergency. The deployment of a U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA) monitoring and assessment team to Japan in the wake of the March 2011 accident at Fukushima Daiichi Nuclear Power Plant yielded a wealth of lessons on these difference. Critical teams (CMOC (Consequence Management Outside the Continental U.S.) and CMHT (Consequence Management Home Team) ) worked together to collect, compile, review,more » and analyze radiological data from Japan to support the response needs of and answer questions from the Government of Japan, the U.S. military in Japan, the U.S. Embassy and U.S. citizens in Japan, and U.S. citizens in America. This paper addresses the unique challenges presented to the health physicist or analyst of radiological data in a large-scale emergency. A key lesson learned was that public perception and the availability of technology with social media requires a diligent effort to keep the public informed of the science behind the decisions in a manner that is meaningful to them.« less
Iodinated contrast media electro-degradation: process performance and degradation pathways.
Del Moro, Guido; Pastore, Carlo; Di Iaconi, Claudio; Mascolo, Giuseppe
2015-02-15
The electrochemical degradation of six of the most widely used iodinated contrast media was investigated. Batch experiments were performed under constant current conditions using two DSA® electrodes (titanium coated with a proprietary and patented mixed metal oxide solution of precious metals such as iridium, ruthenium, platinum, rhodium and tantalum). The degradation removal never fell below 85% (at a current density of 64 mA/cm(2) with a reaction time of 150 min) when perchlorate was used as the supporting electrolyte; however, when sulphate was used, the degradation performance was above 80% (at a current density of 64 mA/cm(2) with a reaction time of 150 min) for all of the compounds studied. Three main degradation pathways were identified, namely, the reductive de-iodination of the aromatic ring, the reduction of alkyl aromatic amides to simple amides and the de-acylation of N-aromatic amides to produce aromatic amines. However, as amidotrizoate is an aromatic carboxylate, this is added via the decarboxylation reaction. The investigation did not reveal toxicity except for the lower current density used, which has shown a modest toxicity, most likely for some reaction intermediates that are not further degraded. In order to obtain total removal of the contrast media, it was necessary to employ a current intensity between 118 and 182 mA/cm(2) with energy consumption higher than 370 kWh/m(3). Overall, the electrochemical degradation was revealed to be a reliable process for the treatment of iodinated contrast media that can be found in contaminated waters such as hospital wastewater or pharmaceutical waste-contaminated streams. Copyright © 2014 Elsevier B.V. All rights reserved.
Seitz, Cornelia S; Pfeuffer, Petra; Raith, Petra; Bröcker, Eva-B; Trautmann, Axel
2009-10-01
All iodinated radiocontrast media (RCM) may cause hypersensitivity reactions, either immediate-type within 5-10 min of RCM injection or delayed-type, which become apparent more than 1h after RCM exposure. Delayed-type hypersensitivity to RCM may pose a problem for future radiologic investigations because due to possible immunological cross-reactivity all iodinated RCM are usually avoided. The aim of this study was not only to identify the causal RCM for the exanthema but also to demonstrate that patients may receive alternative iodinated RCM despite a history of RCM-induced allergic exanthema. We evaluated 32 patients with a history of exanthema after RCM application using standardized patch, prick and intradermal skin testing. In case of positive skin tests intravenous challenges with skin-test-negative RCM were performed to identify non-ionic monomer RCM which are tolerated. In 6 out of 32 patients skin tests strongly suggested a delayed-type non-IgE-mediated allergic hypersensitivity to the RCM iomeprol (3x), iopromide (2x), and iopamidol. In 4 patients alternative non-ionic monomer RCM (2x iosarcol, iopromide, and iomeprol) were identified by controlled challenge tests. The evaluation of patients with RCM-associated exanthema should always include appropriate skin tests ensuring that patients with a delayed-type allergic RCM-induced exanthema are not missed. Moreover, allergologic testing may identify alternative RCM of the group of non-ionic monomers, which are tolerated in future radiologic investigations.
Do we need gadolinium-based contrast medium for brain magnetic resonance imaging in children?
Dünger, Dennis; Krause, Matthias; Gräfe, Daniel; Merkenschlager, Andreas; Roth, Christian; Sorge, Ina
2018-06-01
Brain imaging is the most common examination in pediatric magnetic resonance imaging (MRI), often combined with the use of a gadolinium-based contrast medium. The application of gadolinium-based contrast medium poses some risk. There is limited evidence of the benefits of contrast medium in pediatric brain imaging. To assess the diagnostic gain of contrast-enhanced sequences in brain MRI when the unenhanced sequences are normal. We retrospectively assessed 6,683 brain MR examinations using contrast medium in children younger than 16 years in the pediatric radiology department of the University Hospital Leipzig to determine whether contrast-enhanced sequences delivered additional, clinically relevant information to pre-contrast sequences. All examinations were executed using a 1.5-T or a 3-T system. In 8 of 3,003 (95% confidence interval 0.12-0.52%) unenhanced normal brain examinations, a relevant additional finding was detected when contrast medium was administered. Contrast enhancement led to a change in diagnosis in only one of these cases. Children with a normal pre-contrast brain MRI rarely benefit from contrast medium application. Comparing these results to the risks and disadvantages of a routine gadolinium application, there is substantiated numerical evidence for avoiding routine administration of gadolinium in a pre-contrast normal MRI examination.
Andrade, Cristiane Ps; Souza, Cláudio J; Camerini, Eduardo Sn; Alves, Isabela S; Vital, Hélio C; Healy, Matthew Jf; Ramos De Andrade, Edson
2018-06-01
A radiological dispersive device (RDD) spreads radioactive material, complicates the treatment of physical injuries, raises cancer risk, and induces disproportionate fear. Simulating such an event enables more effective and efficient utilization of the triage and treatment resources of staff, facilities, and space. Fast simulation can give detail on events in progress or future events. The resources for triage and treatment of contaminated trauma victims can differ for pure exposure individuals, while discouraging the "worried well" from presenting in the crisis phase by media announcement would relieve pressure on hospital facilities. The proposed methodology integrates capabilities from different platforms in a convergent way composed of three phases: (a) scenario simulation, (b) data generation, and (c) risk assessment for triage focused on follow-up epidemiological assessment. Simulations typically indicate that most of the affected population does not require immediate medical assistance. Medical triage for the few severely injured and the radiological triage to diminish the contamination with radioactivity will always be the priority. For this study, however, higher priorities should be given to individuals from radiological "warm" and "hot" zones as required by risk criteria. The proposed methodology could thus help to (a) filter and reduce the number of individuals to be attended, (b) optimize the prioritization of medical care, (c) reduce or prepare for future costs, (d) effectively locate the operational triage site to avoid possible contamination on the main facility, and (e) provide the scientific data needed to develop an adequate approach to risk and its proper communication.
TU-CD-BRA-01: A Novel 3D Registration Method for Multiparametric Radiological Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akhbardeh, A; Parekth, VS; Jacobs, MA
2015-06-15
Purpose: Multiparametric and multimodality radiological imaging methods, such as, magnetic resonance imaging(MRI), computed tomography(CT), and positron emission tomography(PET), provide multiple types of tissue contrast and anatomical information for clinical diagnosis. However, these radiological modalities are acquired using very different technical parameters, e.g.,field of view(FOV), matrix size, and scan planes, which, can lead to challenges in registering the different data sets. Therefore, we developed a hybrid registration method based on 3D wavelet transformation and 3D interpolations that performs 3D resampling and rotation of the target radiological images without loss of information Methods: T1-weighted, T2-weighted, diffusion-weighted-imaging(DWI), dynamic-contrast-enhanced(DCE) MRI and PET/CT were usedmore » in the registration algorithm from breast and prostate data at 3T MRI and multimodality(PET/CT) cases. The hybrid registration scheme consists of several steps to reslice and match each modality using a combination of 3D wavelets, interpolations, and affine registration steps. First, orthogonal reslicing is performed to equalize FOV, matrix sizes and the number of slices using wavelet transformation. Second, angular resampling of the target data is performed to match the reference data. Finally, using optimized angles from resampling, 3D registration is performed using similarity transformation(scaling and translation) between the reference and resliced target volume is performed. After registration, the mean-square-error(MSE) and Dice Similarity(DS) between the reference and registered target volumes were calculated. Results: The 3D registration method registered synthetic and clinical data with significant improvement(p<0.05) of overlap between anatomical structures. After transforming and deforming the synthetic data, the MSE and Dice similarity were 0.12 and 0.99. The average improvement of the MSE in breast was 62%(0.27 to 0.10) and prostate was 63%(0.13 to 0.04;p<0.05). The Dice similarity was in breast 8%(0.91 to 0.99) and for prostate was 89%(0.01 to 0.90;p<0.05) Conclusion: Our 3D wavelet hybrid registration approach registered diverse breast and prostate data of different radiological images(MR/PET/CT) with a high accuracy.« less
Understanding and preventing contrast-induced acute kidney injury.
Fähling, Michael; Seeliger, Erdmann; Patzak, Andreas; Persson, Pontus B
2017-03-01
Contrast-induced acute kidney injury (CIAKI) occurs in up to 30% of patients who receive iodinated contrast media and is generally considered to be the third most common cause of hospital-acquired AKI. Accurate assessment of the incidence of CIAKI is obscured, however, by the use of various definitions for diagnosis, the different populations studied and the prophylactic measures put in place. A deeper understanding of the mechanisms that underlie CIAKI is required to enable reliable risk assessment for individual patients, as their medical histories will determine the specific pathways by which contrast media administration might lead to kidney damage. Here, we highlight common triggers that prompt the development of CIAKI and the subsequent mechanisms that ultimately cause kidney damage. We also discuss effective protective measures, such as rapidly acting oral hydration schemes and loop diuretics, in the context of CIAKI pathophysiology. Understanding of how CIAKI arises in different patient groups could enable a marked reduction in incidence and improved outcomes. The ultimate goal is to shape CIAKI prevention strategies for individual patients.
Human pharmacokinetics of iohexol. A new nonionic contrast medium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olsson, B.; Aulie, A.; Sveen, K.
1983-03-01
The pharmacokinetics of iohexol, a new nonionic, water-soluble contrast medium, have been determined after intravenous injection in 20 healthy volunteers, at four different dose levels (125-500 mg I/kg). The apparent volume of distribution was 0.27 1/kg, indicating distribution in the extracellular water. The biologic half-life was 121 minutes, comparable with that of other intravascular contrast media. Iohexol was excreted completely unmetabolized in the urine, with a 100% recovery 24 hours after injection. A comparison of iohexol and chromium-51 (/sup 51/Cr)-EDTA clearances indicates that iohexol is mainly excreted by glomerular filtration. The /sup 51/Cr-EDTA clearance was the same when injected separatelymore » and concomitantly with iohexol, indicating that glomerular filtration rate is not affected by iohexol. No dose dependency was observed in the investigated parameters t1/2 alpha, t1/2 beta, Vd, ClT or ClR. Iohexol pharmacokinetics are in correspondence with previously reported data on intravascular contrast media.« less
Sense about Sex: Media, Sex Advice, Education and Learning
ERIC Educational Resources Information Center
Attwood, Feona; Barker, Meg John; Boynton, Petra; Hancock, Justin
2015-01-01
The media are widely acknowledged as important in sex and relationship education, but they are usually associated with "bad" effects on young people in contrast to the "good" knowledge represented by more informational and educational formats. In this paper we look at sex advice giving in newspapers, magazines and television in…
Chapter 8: Youth, Technology, and Media Cultures
ERIC Educational Resources Information Center
Sefton-Green, Julian
2006-01-01
This chapter begins with a scenario contrasting two seemingly different images of child and media from before and after the "digital revolution." The author argues that there is much greater continuity in how this relationship has been conceptualized over the period than is commonly imagined. While not offering a comprehensive study of recent…
NASA Astrophysics Data System (ADS)
Liu, Hong; Nodine, Calvin F.
1996-07-01
This paper presents a generalized image contrast enhancement technique, which equalizes the perceived brightness distribution based on the Heinemann contrast discrimination model. It is based on the mathematically proven existence of a unique solution to a nonlinear equation, and is formulated with easily tunable parameters. The model uses a two-step log-log representation of luminance contrast between targets and surround in a luminous background setting. The algorithm consists of two nonlinear gray scale mapping functions that have seven parameters, two of which are adjustable Heinemann constants. Another parameter is the background gray level. The remaining four parameters are nonlinear functions of the gray-level distribution of the given image, and can be uniquely determined once the previous three are set. Tests have been carried out to demonstrate the effectiveness of the algorithm for increasing the overall contrast of radiology images. The traditional histogram equalization can be reinterpreted as an image enhancement technique based on the knowledge of human contrast perception. In fact, it is a special case of the proposed algorithm.
Chu, Shichun; Hu, Liuhua; Wang, Xiaolei; Sun, Shiqun; Zhang, Tuo; Sun, Zhe; Shen, Linghong; Jin, Shuxuan; He, Ben
2016-11-01
The aim of this study was to assess the preventive effect of xuezhikang (XZK) to replace atorvastatin on the contrast media-induced acute kidney injury (CI-AKI). The male Sprague-Dawley rats were divided into five groups: group 1 (sham), injected with normal saline; group 2 (XZK), treated with XZK; group 3 contrast media (CM), injected with CM; group 4 (CM + ATO), injected with CM + pretreatment with atorvastatin; group 5 (CM + XZK), injected with CM + pretreatment with XZK. Twenty-four hours after injection with normal saline or CM, the blood sample and the kidneys were collected for the measurement of biochemical parameters, oxidative stress markers, nitric oxide production, inflammatory parameters, as well as renal histopathology and apoptosis detection. Our results indicated that XZK restored the renal function by reducing serum blood urea nitrogen (BUN) and serum creatinine (Scr), depressing renal malondialdehyde (MDA), increasing renal NO production, decreasing TNF-ɑ and IL-6 expression, attenuating renal pathological changes and inhibiting the apoptosis of renal tubular cells. XZK's therapeutic effect is similar, or even better than atorvastatin at the same effectual dose in some parts.
Heunisch, Fabian; von Einem, Gina; Alter, Markus; Weist, Andreas; Dschietzig, Thomas; Kretschmer, Axel; Hocher, Berthold
2014-11-24
Contrast media-induced nephropathy (CIN) is associated with increased morbidity and mortality. The renal endothelin system has been associated with disease progression of various acute and chronic renal diseases. However, robust data coming from adequately powered prospective clinical studies analyzing the short and long-term impacts of the renal ET system in patients with CIN are missing so far. We thus performed a prospective study addressing this topic. We included 327 patients with diabetes or renal impairment undergoing coronary angiography. Blood and spot urine were collected before and 24 h after contrast media (CM) application. Patients were followed for 90 days for major clinical events like need for dialysis, unplanned rehospitalization or death. The concentration of ET-1 and the urinary ET-1/creatinine ratio decreased in spot urine after CM application (ET-1 concentration: 0.91±1.23 pg/ml versus 0.63±1.03 pg/ml, p<0.001; ET-1/creatinine ratio: 0.14±0.23 versus 0.09±0.19, p<0.001). The urinary ET-1 concentrations in patients with CIN decreased significantly more than in patients without CIN (-0.26±1.42 pg/ml vs. -0.79±1.69 pg/ml, p=0.041), whereas the decrease of the urinary ET-1/creatinine ratio was not significantly different (non-CIN patients: -0.05±0.30; CIN patients: -0.11±0.21, p=0.223). Urinary ET-1 concentrations as well as the urinary ET-1/creatinine ratio were not associated with clinical events (need for dialysis, rehospitalization or death) during the 90 day follow-up after contrast media exposure. However, the urinary ET-1 concentration and the urinary ET-1/creatinine ratio after CM application were higher in those patients who had a decrease of GFR of at least 25% after 90 days of follow-up. In general the ET-1 system in the kidney seems to be down-regulated after contrast media application in patients with moderate CIN risk. Major long-term complications of CIN (need for dialysis, rehospitalization or death) are not associated with the renal ET system. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Briguori, Carlo; Visconti, Gabriella; Ricciardelli, Bruno; Condorelli, Gerolama
2011-04-01
The combined prophylactic strategy of sodium bicarbonate plus N-acetylsyteine (NAC) seems to be effective in preventing contrast induced acute kidney injury (CI-AKI) in patients at low-to-medium risk. However, in patients at high and very high risk the rate of CI-AKI is still high. In this subset of patients the anticipated advantages of the RenalGuard(tm) System should be investigated. The RenalGuard(tm) System (PLC Medical Systems, Inc., Franklin, MA, USA) is a real-time measurement and real time matched fluid replacement device designed to accommodate the RenalGuard therapy, which is based on the theory that creating and maintaining a high urine output is beneficial by allowing a quick elimination of contrast media, and, therefore, reducing its toxic effects. The REMEDIAL II trial is a randomised, multicentre, investigator-sponsored trial addressing the hypothesis that the RenalGuard System is superior to the prophylaxis with sodium bicarbonate infusion plus NAC in preventing CI-AKI in high and very high risk patients. Consecutive patients with chronic kidney disease (CKD) and at high to very high risk for CI-AKI, referred to our institutions for coronary and/or peripheral procedures, will be randomly assigned to 1) prophylactic administration of sodium bicarbonate plus NAC (control group) and 2) RenalGuard System treatment (RenalGuard group). All enrolled patients must have an estimated glomerular filtration rate ≤ 30 ml/min/1.73 m2 and/or a contrast nephropathy risk score ≥ 11. In all cases iodixanol (an iso-osmolar, non-ionic contrast agent) will be administered. The primary endpoint is an increase of ≥ 0.3 mg/dL in the serum creatinine concentration 48 hours after the procedure. The REMEDIAL II trial will give important answers on how to prevent CI-AKI in high and very high risk patients undergoing contrast media exposure.
Lakhal, Karim; Ehrmann, Stephan; Chaari, Anis; Laissy, Jean-Pierre; Régnier, Bernard; Wolff, Michel; Pajot, Olivier
2011-12-01
Contrast-induced nephropathy (CIN) has been extensively studied in the ward but only scarcely in intensive care unit (ICU) patients, even if they may be particularly prone to develop or to worsen acute kidney insufficiency. We aimed to measure the incidence of CIN in a large ICU population using the Acute Kidney Injury Network (AKIN) definition and to investigate its impact on patients' outcome. In this 3-year retrospective study, we included all patients undergoing, during their stay in our medical ICU, a contrast media-enhanced computed tomographic scan. Change in serum creatinine between baseline (24 hours before to 12 hours after contrast media injection) and its maximum value over the 96 hours after contrast media injection was recorded. Contrast-induced nephropathy was defined as a 44.2-μmol/L absolute or a 25% relative minimal increase in serum creatinine over 48, 72, or 96 hours and according to the stage 1 of the AKIN classification (at least 26.4 μmol/L or 50% increase over 48 hours). A total of 398 contrast-enhanced computed tomographic scans performed among 299 patients were analyzed. Incidence of CIN was 14% according to the AKIN definition and ranged from 8% (48-hour absolute definition) to 23% (96-hour relative definition). The need for renal replacement therapy and ICU mortality were significantly higher in case of CIN. After adjusting for other variables associated with ICU mortality, the occurrence of at least 1 CIN episode during the ICU stay (AKIN criteria) was independently associated with ICU mortality (odds ratio, 3.85; 95% confidence interval, 1.85-8.00). Even if incidence varied greatly depending on the definition, CIN appeared frequent in our critically ill patients. The AKIN definition, independently associated with ICU mortality, may allow unifying diagnostic criteria to further evaluate this condition that impacts morbidity and mortality. Copyright © 2011 Elsevier Inc. All rights reserved.
Image splitting and remapping method for radiological image compression
NASA Astrophysics Data System (ADS)
Lo, Shih-Chung B.; Shen, Ellen L.; Mun, Seong K.
1990-07-01
A new decomposition method using image splitting and gray-level remapping has been proposed for image compression, particularly for images with high contrast resolution. The effects of this method are especially evident in our radiological image compression study. In our experiments, we tested the impact of this decomposition method on image compression by employing it with two coding techniques on a set of clinically used CT images and several laser film digitized chest radiographs. One of the compression techniques used was full-frame bit-allocation in the discrete cosine transform domain, which has been proven to be an effective technique for radiological image compression. The other compression technique used was vector quantization with pruned tree-structured encoding, which through recent research has also been found to produce a low mean-square-error and a high compression ratio. The parameters we used in this study were mean-square-error and the bit rate required for the compressed file. In addition to these parameters, the difference between the original and reconstructed images will be presented so that the specific artifacts generated by both techniques can be discerned by visual perception.
Medulloblastoma with Atypical Dynamic Imaging Changes: Case Report with Literature Review.
Song, Shuang-Shuang; Wang, Jian-Hong; Fu, Wei-Wei; Li, Ying; Sui, Qing-Lan; Liu, Xue-Jun
2017-09-01
We analyzed a case of medulloblastoma with atypical dynamic imaging changes retrospectively to summarize the atypical magnetic resonance imaging (MRI) features of medulloblastoma by reviewing the literature. An atypical case of medulloblastoma in the cerebellar hemisphere confirmed by pathology was analyzed retrospectively, and the literature about it was reviewed. The radiologic findings of the patient were based on 3 examinations. The first examination showed that the cortex of the bilateral cerebellar hemisphere had diffuse nodular thickening, with a high signal on diffusion-weighted imaging and significant enhancement. Contrast enhancement MRI 1 year later showed the signal of cerebellar hemisphere returned to normal but revealed an enhanced nodule. A reexamination 6 months later showed an irregular mass with a high-density shadow in the cerebellar vermis on CT scan. The T2-weighted image revealed multiple degenerative cysts, and the mass had significant enhancement. The radiologic characteristics of atypical medulloblastomas vary in adults and children. Understanding the radiologic characteristics of medulloblastomas, such as MRI features, age of onset, and location of atypical medulloblastomas, can help improve the diagnosis of medulloblastomas. Copyright © 2017. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Tsai, W. L.; Hwu, Y.; Chen, C. H.; Chang, L. W.; Je, J. H.; Lin, H. M.; Margaritondo, G.
2003-01-01
Phase contrast radiology using unmonochromatic synchrotron X-ray successfully imaged the grain boundaries of Al and AlZn alloy without contrast agent. Combining the high penetration of X-ray and the possibility of 3D reconstruction by tomorgraphy or stereography method, this approach can be very used for nondestructive characterization of polycrystalline materials. By examine the images with 3D perspective, we were able locate the observed void-like defects which lies exclusively on the grain boundary and identify their origin from last stage of the rolling process. We studied the Ga Liquid metal diffusion in the AlZn alloy, under different temperature and stress conditions. High resolution images, ˜2 μm, of Ga liquid metal diffusion in AlZn were obtained in real time and diffusion paths alone grain boundaries and surfaces were clearly identified. Embrittled AlZn responses to the tensile stress and fractures in a drastic different manner than the pure AlZn. These results, although very much expected from the known weakening effect of the liquid metal embrittlement demonstrated, however, that this particular radiology method is fully capable of dynamic study in the micrometer scale.
NASA Astrophysics Data System (ADS)
Lee, Hyoung-In; Mok, Jinsik
2018-05-01
We investigate electromagnetic waves propagating through non-magnetic and loss-free dielectric media, but with spatially inhomogeneous refractive indices. We derive hence a set of analytic formulae for conservation laws and energy-current (Poynting) vector. As a result, we deduce that the energy-current vector cannot be neatly separated into its orbital and spin parts in contrast to the cases with spatially homogeneous media. In addition, we present physical interpretations of the two additional terms due to spatial material inhomogeneity.
Radwan, Ahmed Bassiuony; El-Debeiky, Mohammed Soliman; Abdel-Hay, Sameh
2015-08-01
Overflow retentive stool incontinence (ORSI) is secondary to constipation and fecal loading. In our study, the dose and duration of senna-based laxatives (SBL) treatment to achieve full defecatory control will be examined for possible correlation with new parameters measured from the initial contrast enema. Initially, an observational study was conducted prospectively on a group of patient with ORSI to define the optimum dose of SBL to achieve full defecatory control with measurement of six parameters in the initial contrast enema (level of colonic dilatation, recto-anal angle, ratio of maximal diameter of dilated colon to last lumbar spine, ratio of maximum diameter of dilated colon to normal descending colon, immediate and after 24-h post-evacuation residual contrast). The result was analyzed statistically to reach a correlation between the radiological data and prescribed dose. Over 2 and half years, 72 patients were included in the study; their mean age was 6.3 ± 3.33 years. The mean effective starting dose of SBL was 57 ± 18.13 mg/day and the mean effective ending dose was 75 ± 31.68 mg/day. Time lapsed till full defecatory control ranged from 1 to 16 weeks. Statistical correlation revealed that mean effective ending dose of SBL treatment significantly increased with higher levels of colonic dilatation. A weak positive correlation was found for both the mean effective starting and ending doses with the ratio of maximum colonic diameter to last lumbar spine and descending colonic diameters ratio. Senna-based laxatives are effective treatment for overflow retentive stool incontinence and their doses can be adjusted initially depending on the analysis of the radiological data.
Cheungpasitporn, Wisit; Thongprayoon, Charat; Brabec, Brady A.; Edmonds, Peter J.; O'Corragain, Oisin A.; Erickson, Stephen B.
2014-01-01
Background: The reports on efficacy of oral hydration treatment for the prevention of contrast-induced acute kidney injury (CIAKI) in elective radiological procedures and cardiac catheterization remain controversial. Aims: The objective of this meta-analysis was to assess the use of oral hydration regimen for prevention of CIAKI. Materials and Methods: Comprehensive literature searches for randomized controlled trials (RCTs) of outpatient oral hydration treatment was performed using MEDLINE, EMBASE, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials Systematic Reviews, and clinicaltrials.gov from inception until July 4th, 2014. Primary outcome was the incidence of CIAKI. Results: Six prospective RCTs were included in our analysis. Of 513patients undergoing elective procedures with contrast exposures,45 patients (8.8%) had CIAKI. Of 241 patients with oral hydration regimen, 23 (9.5%) developed CIAKI. Of 272 patients with intravenous (IV) fluid regimen, 22 (8.1%) had CIAKI. Study populations in all included studies had relatively normal kidney function to chronic kidney disease (CKD) stage 3. There was no significant increased risk of CIAKI in oral fluid regimen group compared toIV fluid regimen group (RR = 0.94, 95% confidence interval, CI = 0.38-2.31). Conclusions: According to our analysis,there is no evidence that oral fluid regimen is associated with more risk of CIAKI in patients undergoing elective procedures with contrast exposures compared to IV fluid regimen. This finding suggests that the oral fluid regimen might be considered as a possible outpatient treatment option for CIAKI prevention in patients with normal to moderately reduced kidney function. PMID:25599049
Assessing the Content of YouTube Videos in Educating Patients Regarding Common Imaging Examinations.
Rosenkrantz, Andrew B; Won, Eugene; Doshi, Ankur M
2016-12-01
To assess the content of currently available YouTube videos seeking to educate patients regarding commonly performed imaging examinations. After initial testing of possible search terms, the first two pages of YouTube search results for "CT scan," "MRI," "ultrasound patient," "PET scan," and "mammogram" were reviewed to identify educational patient videos created by health organizations. Sixty-three included videos were viewed and assessed for a range of features. Average views per video were highest for MRI (293,362) and mammography (151,664). Twenty-seven percent of videos used a nontraditional format (eg, animation, song, humor). All videos (100.0%) depicted a patient undergoing the examination, 84.1% a technologist, and 20.6% a radiologist; 69.8% mentioned examination lengths, 65.1% potential pain/discomfort, 41.3% potential radiation, 36.5% a radiology report/results, 27.0% the radiologist's role in interpretation, and 13.3% laboratory work. For CT, 68.8% mentioned intravenous contrast and 37.5% mentioned contrast safety. For MRI, 93.8% mentioned claustrophobia, 87.5% noise, 75.0% need to sit still, 68.8% metal safety, 50.0% intravenous contrast, and 0.0% contrast safety. For ultrasound, 85.7% mentioned use of gel. For PET, 92.3% mentioned radiotracer injection, 61.5% fasting, and 46.2% diabetic precautions. For mammography, unrobing, avoiding deodorant, and possible additional images were all mentioned by 63.6%; dense breasts were mentioned by 0.0%. Educational patient videos on YouTube regarding common imaging examinations received high public interest and may provide a valuable patient resource. Videos most consistently provided information detailing the examination experience and less consistently provided safety information or described the presence and role of the radiologist. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Picture archiving and computing systems: the key to enterprise digital imaging.
Krohn, Richard
2002-09-01
The utopian view of the electronic medical record includes the digital transformation of all aspects of patient information. Historically, imagery from the radiology, cardiology, ophthalmology, and pathology departments, as well as the emergency room, has been a morass of paper, film, and other media, isolated within each department's system architecture. In answer to this dilemma, picture archiving and computing systems have become the focal point of efforts to create a single platform for the collection, storage, and distribution of clinical imagery throughout the health care enterprise.
Marchal, F
2006-03-22
Role of Helicobacter Pylori and nasopharyngeal bacteries in the pathogenesis of otitis media. Interest of Tonsillectomy in MRSA positive patients. Sleep apnea syndrome increases sudden death during night. Prevalence of Acoustic Neuroma, and surgical difficulties in case of conservative treatment failures. Role of CRP in the sinus treatment's decision. Is sinusitis influenced by anatomical factors? Do we have to treat with antibiotics? Role of mycosis? Are the sprays for snorers efficient? Is the facial nerve now radiologically visible? Are systematic punctures of thyroid nodules mandatory and with what frequency? Cetuximab is a promessing treatment in ENT.
NASA Astrophysics Data System (ADS)
Wiebe, S.; Rhoades, G.; Wei, Z.; Rosenberg, A.; Belev, G.; Chapman, D.
2013-05-01
Refraction x-ray contrast is an imaging modality used primarily in a research setting at synchrotron facilities, which have a biomedical imaging research program. The most common method for exploiting refraction contrast is by using a technique called Diffraction Enhanced Imaging (DEI). The DEI apparatus allows the detection of refraction between two materials and produces a unique ''edge enhanced'' contrast appearance, very different from the traditional absorption x-ray imaging used in clinical radiology. In this paper we aim to explain the features of x-ray refraction contrast as a typical clinical radiologist would understand. Then a discussion regarding what needs to be considered in the interpretation of the refraction image takes place. Finally we present a discussion about the limitations of planar refraction imaging and the potential of DEI Computed Tomography. This is an original work that has not been submitted to any other source for publication. The authors have no commercial interests or conflicts of interest to disclose.
Quality assurance in mammography: College of Radiology Survey in Malaysia.
Ho, E L M; Ng, K H; Wong, J H D; Wang, H B
2006-06-01
Malaysia's mammography QA practice was surveyed based on the Malaysian Ministry of Health and the American College of Radiology (ACR) requirements. Data on mammography unit, processor, image receptor, exposure factors, mean glandular dose (MGD), sensitometry, image quality and viewbox luminance were obtained. Mean developer temperature and cycle time were 34.1 +/- 1.8degreesC and 107.7 +/- 33.2 seconds. Mean base+fog level, speed index and contrast index were 0.20+/-0.01, 1.20+/-0.01 and 1.33+/-0.26 respectively. Eighty-six percent of the fifty centres passed the image quality test while 12.5% complied with ACR recommended viewbox luminance. Average MGD was 1.0+/-0.4 mGy. Malaysia is on the right track for QA but with room for total quality improvement.
The use of clinical contrast media for lymphangiography in cadaveric studies.
Pan, Wei-Ren; Le Roux, Cara Michelle; Rozen, Warren M
2009-01-01
Radiographic contrast media have not been previously used in human lymphatic cadaver studies. As these will have further clinical applications, we sought to investigate their use in this role. Both lower legs from an unembalmed human cadaver were studied. We used hydrogen peroxide to identify the lymphatics of the dorsum of the foot, and a single lymphatic was microsurgically injected with 1 ml of 76% 'Urografin.' A series of radiographs were taken 1 min after injection and for 2.5 h until the Urografin vanished. Images were digitalized for analysis. The series of lymphangiograms generated showed the size, location, and course of the lymphatics in the leg. Over time, the density of the iodinated contrast in the lymphatic vessels reduced and disappeared completely after 2.5 hours postinjection. A 'digitally subtracted' image provided a clear and high-contrast lymphangiogram. The lymphatic network identified was shown to diverge and converge twice as it coursed proximally up the limb. Urografin, a clinical radiographic contrast medium, was shown to lose contrast density 2.5 h following cadaveric intralymphatic injection. The use of a new technique, that of 'digital subtraction lymphangiography,' was able to demonstrate the lymphatic vessel pathways clearly, and is a useful technique for cadaveric lymphatic studies.
Mono-Energy Coronary Angiography with a Compact Synchrotron Source
NASA Astrophysics Data System (ADS)
Eggl, Elena; Mechlem, Korbinian; Braig, Eva; Kulpe, Stephanie; Dierolf, Martin; Günther, Benedikt; Achterhold, Klaus; Herzen, Julia; Gleich, Bernhard; Rummeny, Ernst; Noёl, Peter B.; Pfeiffer, Franz; Muenzel, Daniela
2017-02-01
X-ray coronary angiography is an invaluable tool for the diagnosis of coronary artery disease. However, the use of iodine-based contrast media can be contraindicated for patients who present with chronic renal insufficiency or with severe iodine allergy. These patients could benefit from a reduced contrast agent concentration, possibly achieved through application of a mono-energetic x-ray beam. While large-scale synchrotrons are impractical for daily clinical use, the technology of compact synchrotron sources strongly advanced during the last decade. Here we present a quantitative analysis of the benefits a compact synchrotron source can offer in coronary angiography. Simulated projection data from quasi-mono-energetic and conventional x-ray tube spectra is used for a CNR comparison. Results show that compact synchrotron spectra would allow for a significant reduction of contrast media. Experimentally, we demonstrate the feasibility of coronary angiography at the Munich Compact Light Source, the first commercial installation of a compact synchrotron source.
Pérez-Guzmán, Carlos; Vargas, Mario H; Torre-Bouscoulet, Luis
2008-01-01
To describe clinical and radiological features of patients with pleural mesothelioma, according to main histological types. Clinical records of inpatients admitted with diagnosis of pleural mesothelioma to the Instituto Nacional de Enfermedades Respiratorias in the last 11 years, were reviewed. We analyzed 85 cases confirmed by immunohistochemistry. The most frequent histological type was epithelial (84.7 %), followed by sarcomatous (12.9 %) and mixed (2.4 %) types. Comparison between epithelial and sarcomatous types showed no differences in age (53.7 +/- 13.1 vs. 55.9 +/- 11.0 years, respectively), male : female ratio (2.3 : 1 vs. 1.8 : 1), history of asbestos exposure (34.7 vs. 27.2 %), tobacco habit (54.2 vs 45.4 %), occupation, evolution time (4.8 +/- 3.3 vs. 4.4 +/- 3.7 months), pain, dyspnea and cough, right-side predominance (55.6 vs. 81.8 %), radiological image with pleural effusion (59.7 vs. 36.4 %) or pleural thickening (38.9 vs. 63.6 %), and diagnostic efficiency of closed pleural biopsy (58.3 vs. 27.2 %). Our results suggest that clinical and radiological features of epithelial and sarcomatous histological types are very similar. Additionally, we found a high frequency of epithelial mesothelioma, which contrasts with findings from other countries, suggesting that the type of asbestos or other factors involved in the development of pleural mesothelioma differ from those existing in other regions of the world.
Improving Quality and Efficiency for Intussusception Management After Successful Enema Reduction.
Raval, Mehul V; Minneci, Peter C; Deans, Katherine J; Kurtovic, Kelli J; Dietrich, Ann; Bates, D Gregory; Rangel, Shawn J; Moss, R Lawrence; Kenney, Brian D
2015-11-01
The purpose of this project was to implement a protocol facilitating discharge from the emergency department (ED) after successful radiologic ileocolic intussusception reduction in a pediatric referral center. A multidisciplinary team identified drivers for successful quality improvement including educational brochures, a standardized radiologic report, an observation period in the ER with oral hydration challenges, and follow-up phone calls the day after discharge. Patient outcomes were tracked, and quarterly feedback was provided. Of 80 patients identified over a 24-month period, 34 (42.5%) did not qualify for discharge home due to need for surgical intervention (n = 9), specific radiologic findings (n = 11), need for additional intravenous hydration (n = 4), or other reasons (n = 7). Of 46 patients who qualified for discharge, 30 (65.2%) were successfully sent home from the ED. One patient returned with recurrent symptoms that required repeat enema reduction. Sixteen patients were observed and discharged within 23 hours. Adherence with discharge from the ED improved over time. Discharge from the ED was associated with cost savings and improved net margins at the hospital level for each encounter. A sustainable multidisciplinary quality improvement project to discharge intussusception patients from the ED after air-contrast enema reduction was successfully integrated in a high-volume referral center through education, standardized radiologic reporting, and protocoled follow-up. Copyright © 2015 by the American Academy of Pediatrics.
Natural history of incidental World Health Organization grade II gliomas.
Pallud, Johan; Fontaine, Denys; Duffau, Hugues; Mandonnet, Emmanuel; Sanai, Nader; Taillandier, Luc; Peruzzi, Philippe; Guillevin, Rémy; Bauchet, Luc; Bernier, Valérie; Baron, Marie-Hélène; Guyotat, Jacques; Capelle, Laurent
2010-11-01
Seizure is the presenting symptom in most of World Health Organization grade II gliomas (GIIGs). Rarely, a GIIG is discovered incidentally on imaging. Little is known about the natural course and prognosis of incidental GIIGs. The aim of the present study is to characterize their natural history and to investigate whether their clinical and radiological behaviors differ from those of symptomatic GIIGs. The clinical and radiological findings, treatments, and outcomes of 47 histologically-proven incidental GIIGs were compared with those of 1249 symptomatic GIIGs. Incidental GIIGs differ significantly from symptomatic GIIGs: they have a female predominance (p = 0.05), smaller initial tumor volumes (p < 0.001), lower incidence of contrast enhancement (p = 0.009), and are more likely to undergo gross total surgical removal (p < 0.001). Proliferation rates were similar to that observed among symptomatic GIIGs. Younger age at the time of discovery, frontal lobes, and noneloquent brain regions were associated with incidental GIIGs, as compared to their symptomatic counterparts. When not treated, incidental GIIGs demonstrated radiological growth (median velocity of diametric expansion at 3.5 mm/year), and became symptomatic at a median interval of 48 months after radiological discovery. Overall, incidental discovery was associated with a significant survival benefit (p = 0.04). Incidental GIIGs are progressive tumors leading to clinical transformation toward symptomatic GIIGs. They may represent an earlier step in the natural history of a glioma than the symptomatic GIIGs.
Gohn-Kreuz, Cristian; Rohrbach, Alexander
2016-03-21
Self-reconstruction of Bessel beams in inhomogeneous media is beneficial in light-sheet based microscopy. Although the beam's ring system enables propagation stability, the resulting image contrast is reduced. Here, we show that by a combination of two self-reconstructing beams with different orbital angular momenta it is possible to inhibit fluorescence from the ring system by using stimulated emission depletion (STED) even in strongly scattering media. Our theoretical study shows that the remaining fluorescence γ depends non-linearly on the beams' relative radial and orbital angular momenta. For various scattering media we demonstrate that γ remains remarkably stable over long beam propagation distances.
Perko, T; Tomkiv, Y; Oughton, D H; Cantone, M C; Gallego, E; Prezelj, I; Byrkina, E
2015-04-01
Using an analysis of the way European newspapers covered the Fukushima nuclear accident, this article explores how the mass media transmit information about radiation risks from experts to the general public. The study applied a media content analysis method on a total of 1340 articles from 12 leading newspapers in 6 countries: Belgium (N = 260), Italy (N = 270), Norway (N = 133), Russia (N = 172), Slovenia (N = 190) and Spain (N = 315). All articles analysed were selected as being directly or indirectly related to the Fukushima accident by containing the word 'nuclear' and/or 'Fukushima' and were published between the 11th March and the 11th May 2011. The data presented here focus specifically on a cross-cultural comparison of the way the media use quantitative units. Results suggest that although experts are accustomed to communicating about radiological risks in technical language, often using quantitative units to describe the risks, mass media do not tend to use these units in their reporting. Although the study found a large variation in the measurement units used in different countries, it appeared that journalists in all the analysed countries preferred to describe radioactivity by comparing different radiation exposures, rather than reporting the actual measured units. The paper concludes with some practical guidelines for sound public communication about radiation risks. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Routine Use of Contrast Swallow After Total Gastrectomy and Esophagectomy: Is it Justified?
El-Sourani, Nader; Bruns, Helge; Troja, Achim; Raab, Hans-Rudolf; Antolovic, Dalibor
2017-01-01
After gastrectomy or esophagectomy, esophagogastrostomy and esophagojejunostomy are commonly used for reconstruction. Water-soluble contrast swallow is often used as a routine screening to exclude anastomotic leakage during the first postoperative week. In this retrospective study, the sensitivity and specificity of oral water-soluble contrast swallow for the detection of anastomotic leakage and its clinical symptoms were analysed. Records of 104 consecutive total gastrectomies and distal esophagectomies were analysed. In all cases, upper gastrointestinal contrast swallow with the use of a water-soluble contrast agent was performed on the 5 th postoperative day. Extravasation of the contrast agent was defined as anastomotic leakage. When anastomotic insufficiency was suspected but no extravasation was present, a computed tomography (CT) scan and upper endoscopy were performed. Oral contrast swallow detected 7 anastomotic leaks. Based on CT-scans and upper endoscopy, the true number of anastomotic leakage was 15. The findings of the oral contrast swallow were falsely positive in 4 and falsely negative in 12 patients, respectively. The sensitivity and specificity of the oral contrast swallow was 20% and 96%, respectively. Routine radiological contrast swallow following total gastrectomy or distal esophagectomy cannot be recommended. When symptoms of anastomotic leakage are present, a CT-scan and endoscopy are currently the methods of choice.
Tawn, D J; Squire, C J; Mohammed, M A; Adam, E J
2005-05-01
To audit the sensitivity of double-contrast barium enema (DCBE) for colorectal carcinoma, as currently practised in UK departments of radiology. As part of its programme of national audits, the Royal College of Radiologists Clinical Radiology Audit Sub-Committee undertook a retrospective audit of the sensitivity of DCBE for colorectal carcinoma during 2002. The following targets were set: demonstration of a lesion > or =95%; correct identification as a carcinoma > or =90%. Across the UK, 131 departments took part in the audit, involving 5454 examinations. The mean demonstration rate was 92.9% and the diagnosis rate was 85.9%, slightly below the targets set. The equivocal rate (lesion demonstrated, but not defined as malignant) was 6.9%, the perception failure rate was 2.8% and the technical failure rate was 4.4%. Control-chart methodology was used to analyze the data and to identify any departments whose performance was consistent with special-cause variation. When compared with the diagnosis rate (84.6%) and demonstration rate (92.7%) reported in the Wessex Audit 1995, [Thomas RD, Fairhurst JJ, Frost RA. Wessex regional audit: barium enema in colo-rectal carcinoma. Clin Radiol 1995;50:647-50.] a similar level of performance was observed in the NHS today, implying that the basic process for undertaking and reporting DCBE has remained relatively unchanged over the last few years. Improvement in the future will require fundamental changes to the process of reporting DCBE, in order to minimize the perception failure rate and accurately to describe lesions, so reducing the equivocal rate. Control-chart methodology has a useful role in identifying strategies to deliver continual improvement.
Lodixanol inhibits exogenous surfactant therapy in rats with acute respiratory distress syndrome.
Kesecioglu, J; Schultz, M J; Haitsma, J J; den Heeten, G J; Lachmann, B
2002-05-01
Optimal alveolar distribution of exogenous surfactant is an important determinant of its beneficial effect. This distribution can be determined by suspending surfactant in a radiological contrast medium before intratracheal instillation, followed by radiological imaging. Iodixanol is reported to be a safe contrast medium that causes no lung injury when instilled intratracheally. In this study, the effects of surfactant suspended in saline were compared with surfactant suspended either in 4:1 saline-iodixanol (64 mg iodine x mL(-1)) or in 1:1 saline-iodixanol (160 mg iodine x mL(-1)), on oxygenation and lung mechanics in a rat model of adult respiratory distress syndrome (ARDS) induced by lung lavage. After the induction of ARDS, surfactant instillation improved oxygenation, total lung volume at inflation with a distending pressure of 35 cmH2O, lung volume at transpulmonary pressure of 5 cmH2O and Gruenwald index. The effects of surfactant suspended in 4:1 saline-iodixanol were similar to those of surfactant alone. However, instillation of surfactant suspended in 1:1 saline-iodixanol resulted in significantly lower values in all measured parameters. Surface tension was the lowest in surfactant suspended in saline alone and addition of iodixanol led to an increase in surface tension in a dose-dependent manner. In conclusion, iodixanol at the higher dose caused an inhibition of the exogenous surfactant effect, characterized as a lack of improvement in oxygen tension in arterial blood, low total lung compliance, volume at 5 cmH2O end-expiration and Gruenwald index. This effect of iodixanol was probably due to its high surface tension, especially if a high concentration was used. Surfactant suspended in a lower concentration of iodixanol seems a better alternative, allowing for radiological imaging of the distribution of surfactant when intratracheally instilled.
Colombo, Giorgio L; Andreis, Ivo A Bergamo; Di Matteo, Sergio; Bruno, Giacomo M; Mondellini, Claudio
2013-01-01
The utilization of diagnostic imaging has substantially increased over the past decade in Europe and North America and continues to grow worldwide. The purpose of this study was to develop an economic evaluation of a syringeless power injector (PI) versus a dual-syringe PI for contrast enhanced computed tomography (CECT) in a hospital setting. Patients (n=2379) were enrolled at the Legnano Hospital between November 2012 and January 2013. They had been referred to the hospital for a CECT analysis and were randomized into two groups. The first group was examined with a 256-MDCT (MultiDetector Computed Tomography) scanner using a syringeless power injector, while the other group was examined with a 64-MDCT scanner using a dual-syringe. Data on the operators' time required in the patient analysis steps as well as on the quantity of consumable materials used were collected. The radiologic technologists' satisfaction with the use of the PIs was rated on a 10-point scale. A budget impact analysis and sensitivity analysis were performed under the base-case scenario. A total of 1,040 patients were examined using the syringeless system, and 1,339 with the dual-syringe system; the CECT examination quality was comparable for both PI systems. Equipment preparation time and releasing time per examination for syringeless PIs versus dual-syringe PIs were 100±30 versus 180±30 seconds and 90±30 and 140±20 seconds, respectively. On average, 10±3 mL of contrast media (CM) wastage per examination was observed with the dual-syringe PI and 0±1 mL with the syringeless PI. Technologists had higher satisfaction with the syringeless PI than with the dual-syringe system (8.8 versus 8.0). The syringeless PI allows a saving of about €6.18 per patient, both due to the lower cost of the devices and to the better performance of the syringeless system. The univariate sensitivity analysis carried out on the base-case results within the standard deviation range confirmed the saving generated by using the syringeless device, with saving values between €5.40 and €6.20 per patient. The syringeless PI was found to be more user-friendly and efficient, minimizing contrast wastage and providing similar contrast enhancement quality compared to the dual-syringe injector, with comparable CECT examination quality.
Sterner, Gunnar; Frid, Anders
2018-04-03
Metformin is eliminated through glomerular filtration and tubular secretion in the kidneys. New guidelines recommend use of metformin down to a GFR of 30 mL/min under the condition that the dose is adjusted. As the risk of inducing lactic acidosis is very low in connection with administration of iodine contrast media, new recommendations in Sweden say that metformin must be stopped only when GFR is below 45 mL/min. Determination of metformin levels in serum is useful to guide therapeutic dose when GFR is low but also to confirm that lactic acidosis is caused by metformin.
Use of ultrasmall superparamagnetic iron oxide particles for imaging carotid atherosclerosis.
Usman, Ammara; Sadat, Umar; Patterson, Andrew J; Tang, Tjun Y; Varty, Kevin; Boyle, Jonathan R; Armon, Mathew P; Hayes, Paul D; Graves, Martin J; Gillard, Jonathan H
2015-10-01
Based on the results of histopathological studies, inflammation within atherosclerotic tissue is now widely accepted as a key determinant of the disease process. Conventional imaging methods can highlight the location and degree of luminal stenosis but not the inflammatory activity of the plaque. Iron oxide-based MRI contrast media particularly ultrasmall supermagnetic particles of iron oxide have shown potential in assessing atheromatous plaque inflammation and in determining efficacy of antiatherosclerosis pharmacological treatments. In this paper, we review current data on the use of ultrasmall superparamagnetic iron oxides in atherosclerosis imaging with focus on ferumoxtran-10 and ferumoxytol. The basic chemistry, pharmacokinetics and dynamics, potential applications, limitations and future perspectives of these contrast media nanoparticles are discussed.
Autofluorescence imaging of macular pigment: influence and correction of ocular media opacities
NASA Astrophysics Data System (ADS)
Sharifzadeh, Mohsen; Obana, Akira; Gohto, Yuko; Seto, Takahiko; Gellermann, Werner
2014-09-01
The healthy adult human retina contains in its macular region a high concentration of blue-light absorbing carotenoid compounds, known as macular pigment (MP). Consisting of the carotenoids lutein, zeaxanthin, and meso-zeaxanthin, the MP is thought to shield the vulnerable tissue layers in the retina from light-induced damage through its function as an optical attenuator and to protect the tissue cells within its immediate vicinity through its function as a potent antioxidant. Autofluorescence imaging (AFI) is emerging as a viable optical method for MP screening of large subject populations, for tracking of MP changes over time, and for monitoring MP uptake in response to dietary supplementation. To investigate the influence of ocular media opacities on AFI-based MP measurements, in particular, the influence of lens cataracts, we conducted a clinical trial with a large subject population (93 subjects) measured before and after cataract surgery. General AFI image contrast, retinal blood vessel contrast, and presurgery lens opacity scores [Lens Opacities Classification System III (LOCS III)] were investigated as potential predictors for image degradation. These clinical results show that lens cataracts can severely degrade the achievable pixel contrasts in the AFI images, which results in nominal MP optical density levels that are artifactually reduced. While LOCS III scores and blood vessel contrast are found to be only a weak predictor for this effect, a strong correlation exists between the reduction factor and the image contrast, which can be quantified via pixel intensity histogram parameters. Choosing the base width of the histogram, the presence or absence of ocular media opacities can be determined and, if needed, the nominal MP levels can be corrected with factors depending on the strength of the opacity.
Learned, R.E.; Chao, T.T.; Sanzolone, R.F.
1981-01-01
In experiments designed to determine the manner in which copper is partitioned among selected phases that constitute geologic media, we have applied the five-step sequential extraction procedure of Chao and Theobald to the analysis of drill core, soils, and stream sediments of the Rio Vivi and Rio Tanama porphyry copper districts of Puerto Rico. The extraction procedure affords a convenient means of determining the trace-metal content of the following fractions: (1) Mn oxides and "reactive" Fe oxides; (2) "amorphous" Fe oxides; (3) "crystalline" Fe oxides; (4) sulfides and magnetite; and (5) silicates. An additional extraction between steps (1) and (2) was performed to determine organic-related copper in stream sediments. The experimental results indicate that apportionment of copper among phases constituting geologic media is a function of geochemical environment. Distinctive partitioning patterns were derived from the analysis of drill core from each of three geochemical zones: (a) the supergene zone of oxidation; (b) the supergene zone of enrichment; and (c) the hypogene zone; and similarly, from the analysis of; (d) soils on a weakly leached capping; (e) soils on a strongly leached capping; and (f) active stream sediment. The experimental results also show that geochemical contrasts (anomaly-to-background ratios) vary widely among the five fractions of each sampling medium investigated, and that at least one fraction of each medium provides substantially stronger contrast than does the bulk medium. Fraction (1) provides optimal contrast for stream sediments of the district; fraction (2) provides optimal contrast for soils on a weakly leached capping; fraction (3) provides optimal contrast for soils on a strongly leached capping. Selective extraction procedures appear to have important applications to the orientation and interpretive stages of geochemical exploration. Further investigation and testing of a similar nature are recommended. ?? 1981.
Deloney, Linda A; Perrot, L J; Lensing, Shelly Y; Jambhekar, Kedar
2014-07-01
Residency recruitment is a critical and expensive process. A program's Web site may improve recruitment, but little is known about how applicants use program sites or what constitutes optimal content. The importance of an interview day and interactions with a program's residents has been described, but candidate preferences for various activities and schedules have not been widely reported. We investigated contemporary use and perceived utility of information provided on radiology program Web sites, as well as preferences for the interview day experience. Using an anonymous cross-sectional survey, we studied 111 candidates who were interviewed between November 1, 2012 and January 19, 2013 for a diagnostic radiology residency position at our institution. Participation in this institutional review board-approved study was entirely voluntary, and no identifying information was collected. Responses were sealed and not analyzed until after the match. A total of 70 candidates returned a completed survey (63% response rate). Optimal content considered necessary for a "complete" Web site was identified. The most important factor in deciding where to apply was geographical connection to a program. "AuntMinnie" was the most popular source of program information on social media. Candidates overwhelmingly preferred one-on-one faculty interviews but had no preference between a Saturday and weekday schedule. The ideal interview experience should include a "meet and greet" with residents off campus and a personal interview with the program director. The overall "feel" or "personality" of the program was critical to a candidate's rank order decision. Our findings offer insight into what factors make programs appealing to radiology applicants. This information will be useful to medical educators engaged in career counseling and recruitment. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
The work programme of NERIS in post-accident recovery.
Schneider, T; Andronopoulos, S; Camps, J; Duranova, T; Gallego, E; Gering, F; Isnard, O; Maître, M; Murith, C; Oughton, D; Raskob, W
2018-01-01
NERIS is the European platform on preparedness for nuclear and radiological emergency response and recovery. Created in 2010 with 57 organisations from 28 different countries, the objectives of the platform are to: improve the effectiveness and coherency of current approaches to preparedness; identify further development needs; improve 'know how' and technical expertise; and establish a forum for dialogue and methodological development. The NERIS Strategic Research Agenda is now structured with three main challenges: (i) radiological impact assessments during all phases of nuclear and radiological events; (ii) countermeasures and countermeasure strategies in emergency and recovery, decision support, and disaster informatics; and (iii) setting up a multi-faceted framework for preparedness for emergency response and recovery. The Fukushima accident has highlighted some key issues for further consideration in NERIS research activities, including: the importance of transparency of decision-making processes at local, regional, and national levels; the key role of access to environmental monitoring; the importance of dealing with uncertainties in assessment and management of the different phases of the accident; the use of modern social media in the exchange of information; the role of stakeholder involvement processes in both emergency and recovery situations; considerations of societal, ethical, and economic aspects; and the reinforcement of education and training for various actors. This paper emphasises the main issues at stake for NERIS for post-accident management.
Méndez-Probst, Carlos E; Fernadez, Alfonso; Erdeljan, Petar; Vanjecek, Maaike; Cadieux, Peter A; Razvi, Hassan
2011-03-01
Studies have suggested that shockwave lithotripsy (SWL) stone fragmentation rates can be affected by characteristics of the fluid media surrounding the stone, although evidence to implicate the impact of urine specific gravity (SG) is limited and inconclusive. Our aim is to further explore the impact fluid media and SGs have on stone fragmentation using a variable focus lithotripter. Artificial stones were presoaked for 24 hours in urine and then shocked in various fluid media including artificial urine (SG 1.010 control, 1.020, and 1.07), human pooled urine (HPU), degassed HPU, Pentastarch, 100% and 30% contrast, degassed 30% contrast, 100% ethanol, deionized water (dH(2)O), degassed dH(2)O, 5% glucose, Ringer lactate, 0.9% saline, glycerol, whole blood, and lubricating gel. After soaking, SWL using the Modulith SLX-F2 electromagnetic lithotripter was performed. Fragments were dried and sieved using a 4-mm diameter opening grid. Fragments >4 mm were weighed and fragmentation coefficients (FCs) calculated (pre-SWL weight - post-SWL weight)/(pre-SWL weight) × 100. Fifteen stones were shocked for each fluid group. Fluid type, viscosity, and degassing all significantly impacted stone fragmentation. While the solutions' SG, per se, did not appear to affect stone fragmentation, the use of degassed 30% contrast significantly improved stone destruction over the SG 1.010 artificial urine control (95.3% vs 71.4, P < 0.01). Furthermore, degassing improved comminution rates by increasing the number of completely fragmented stones (FC = 100%). Using degassed 30% contrast, 12/15 stones were completely fragmented, compared with only 2/15 in the control group (P = 0.007). Among the whole blood, glycerol, and lubricating gel groups, only 1/15, 0/15, and 1/15 stones reached 100% FC respectively in the narrow focus, possibly because of the detrimental impact of increased viscosity. Different fluid media can significantly affect FC in vitro. Among the various fluids tested, degassed 30% contrast significantly increased the FC and total number of completely fragmented stones.
Visual Discrimination of Color Normals and Color Deficients. Final Report.
ERIC Educational Resources Information Center
Chen, Yih-Wen
Since visual discrimination is one of the factors involved in learning from instructional media, the present study was designed (1) to investigate the effects of hue contrast, illuminant intensity, brightness contrast, and viewing distance on the discrimination accuracy of those who see color normally and those who do not, and (2) to investigate…
Hughes, Caitlin Elizabeth; Lancaster, Kari; Spicer, Bridget
2011-07-01
Media reporting on illicit issues has been frequently criticised for being sensationalised, biased and narrow. Yet, there have been few broad and systematic analyses of the nature of reporting. Using a large sample and methods commonly adopted in media communications analysis this paper sought to identify the dominant media portrayals used to denote illicit drugs in Australian newspapers and to compare and contrast portrayals across drug types. A retrospective content analysis of Australian print media was carried out over the period 2003-2008 from a sample comprised of 11 newspapers. Articles that contained one or more mention of five different drugs (or derivatives) were identified: cannabis, amphetamines, ecstasy, cocaine and heroin. A sub-sample of 4397 articles was selected for media content analysis (with 2045 selected for full content analysis) and a large number of text elements coded for each. Key elements included topic, explicit or implicit messages about the consequences of drugs/use and three value dimensions: overall tone, whether drugs were portrayed as a crisis issue and moral evaluations of drugs/use. The dominant media portrayals depicted law enforcement or criminal justice action (55%), but most articles were reported in a neutral manner, in the absence of crisis framings. Portrayals differed between drugs, with some containing more narrow frames and more explicit moral evaluations than others. For example, heroin was disproportionately framed as a drug that will lead to legal problems. In contrast, ecstasy and cocaine were much more likely to emphasise health and social problems. Media reporting on illicit drugs is heavily distorted towards crime and deviance framings, but may be less overtly sensationalised, biased and narrowly framed than previously suggested. This is not to suggest there is no sensationalism or imbalance, but this appears more associated with particular drug types and episodes of heightened public concern. Copyright © 2011 Elsevier B.V. All rights reserved.
Contrast-induced acute kidney injury: potential new strategies.
Briguori, Carlo; Donnarumma, Elvira; Quintavalle, Cristina; Fiore, Danilo; Condorelli, Gerolama
2015-03-01
Contrast-induced acute kidney injury (CI-AKI) is an impairment of renal function following contrast media administration in the absence of an alternative cause. It represents a powerful predictor of poor early and late outcomes. Here, we review the major strategies to prevent CI-AKI. Hydration represents the gold standard as a prophylactic measure to prevent CI-AKI, acting by increasing urine flow rate and, thereby, by limiting the time of contact between the contrast media and the tubular epithelial cells. An optimal hydration regimen should be defined according to predefined clinical markers, such as urine flow rate, or left ventricular end-diastolic pressure. Recently, high-dose statins pretreatment has been included in the guidelines of CI-AKI prevention. However, uncertainty still exists on the efficacy of several compounds tested in both observational trials and randomized studies to prevent CI-AKI. Compounds evaluated include diuretics (furosemide), antioxidants (i.e. N-acetylcysteine and statins) and vasodilators (i.e. calcium antagonists, dopamine and fenoldopam). Hydration still represents the most reliable strategy to prevent CI-AKI. New prophylactic strategies for acute kidney injury are still under investigation.
X-ray fluorescence camera for imaging of iodine media in vivo.
Matsukiyo, Hiroshi; Watanabe, Manabu; Sato, Eiichi; Osawa, Akihiro; Enomoto, Toshiyuki; Nagao, Jiro; Abderyim, Purkhet; Aizawa, Katsuo; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Ehara, Shigeru; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2009-01-01
X-ray fluorescence (XRF) analysis is useful for measuring density distributions of contrast media in vivo. An XRF camera was developed for carrying out mapping for iodine-based contrast media used in medical angiography. Objects are exposed by an X-ray beam from a cerium target. Cerium K-series X-rays are absorbed effectively by iodine media in objects, and iodine fluorescence is produced from the objects. Next, iodine Kalpha fluorescence is selected out by use of a 58-microm-thick stannum filter and is detected by a cadmium telluride (CdTe) detector. The Kalpha rays are discriminated out by a multichannel analyzer, and the number of photons is counted by a counter card. The objects are moved and scanned by an x-y stage in conjunction with a two-stage controller, and X-ray images obtained by iodine mapping are shown on a personal computer monitor. The scan pitch of the x and y axes was 2.5 mm, and the photon counting time per mapping point was 2.0 s. We carried out iodine mapping of non-living animals (phantoms), and iodine Kalpha fluorescence was produced from weakly remaining iodine elements in a rabbit skin cancer.
Improvements in Diagnostic Accuracy with Quantitative Dynamic Contrast-Enhanced MRI
2011-12-01
Magnetic Resonance Imaging during the Menstrual Cylce: Perfusion Imaging Signal Enhanceent, and Influence of...acquisition of quantitative images displaying the concentration of contrast media as well as MRI -detectable proton density. To date 21 patients have...truly quantitative images of a dynamic contrast-‐enhanced (DCE) MRI of the
Cross-phase modulation spectral shifting: nonlinear phase contrast in a pump-probe microscope
Wilson, Jesse W.; Samineni, Prathyush; Warren, Warren S.; Fischer, Martin C.
2012-01-01
Microscopy with nonlinear phase contrast is achieved by a simple modification to a nonlinear pump-probe microscope. The technique measures cross-phase modulation by detecting a pump-induced spectral shift in the probe pulse. Images with nonlinear phase contrast are acquired both in transparent and absorptive media. In paraffin-embedded biopsy sections, cross-phase modulation complements the chemically-specific pump-probe images with structural context. PMID:22567580
Rosado-Méndez, I; Palma, B A; Brandan, M E
2008-12-01
Contrast-medium-enhanced digital mammography (CEDM) is an image subtraction technique which might help unmasking lesions embedded in very dense breasts. Previous works have stated the feasibility of CEDM and the imperative need of radiological optimization. This work presents an extension of a former analytical formalism to predict contrast-to-noise ratio (CNR) in subtracted mammograms. The goal is to optimize radiological parameters available in a clinical mammographic unit (x-ray tube anode/filter combination, voltage, and loading) by maximizing CNR and minimizing total mean glandular dose (D(gT)), simulating the experimental application of an iodine-based contrast medium and the image subtraction under dual-energy nontemporal, and single- or dual-energy temporal modalities. Total breast-entrance air kerma is limited to a fixed 8.76 mGy (1 R, similar to screening studies). Mathematical expressions obtained from the formalism are evaluated using computed mammographic x-ray spectra attenuated by an adipose/glandular breast containing an elongated structure filled with an iodinated solution in various concentrations. A systematic study of contrast, its associated variance, and CNR for different spectral combinations is performed, concluding in the proposal of optimum x-ray spectra. The linearity between contrast in subtracted images and iodine mass thickness is proven, including the determination of iodine visualization limits based on Rose's detection criterion. Finally, total breast-entrance air kerma is distributed between both images in various proportions in order to maximize the figure of merit CNR2/D(gT). Predicted results indicate the advantage of temporal subtraction (either single- or dual-energy modalities) with optimum parameters corresponding to high-voltage, strongly hardened Rh/Rh spectra. For temporal techniques, CNR was found to depend mostly on the energy of the iodinated image, and thus reduction in D(gT) could be achieved if the spectral energy of the noniodinated image is decreased and the breast-entrance air kerma is evenly distributed between both acquisitions. Predicted limits, in terms of iodine concentration, are found to guarantee the visualization of common clinical angiogenic concentrations in the breast.
Lee, Yuan-Hao; Chen, Clayton Chi-Chang; Lee, San-Kan; Chen, Cheng-Yu; Wan, Yung-Liang; Guo, Wan-Yuo; Cheng, Amy; Chan, Wing P
2016-09-20
Variations in radiological examination procedures and patient load lead to variations in standards of care related to patient safety and healthcare quality. To understand the status of safety measures to protect patients undergoing radiological examinations at residency training hospitals in Taiwan, a follow-up survey evaluating the full spectrum of diagnostic radiology procedures was conducted. Questionnaires covering 12 patient safety-related themes throughout the examination procedures were mailed to the departments of diagnostic radiology with residency training programmes in 19 medical centres (with >500 beds) and 17 smaller local institutions in Taiwan. After receiving the responses, all themes in 2014 were compared between medical centres and local institutions by using χ(2) or 2-sample t-tests. Radiology Directors or Technology Chiefs of medical centres and local institutions in Taiwan participated in this survey by completing and returning the questionnaires. The response rates of medical centres and local institutions were 95% and 100%, respectively. As indicated, large medical centres carried out more frequent clinically ordered, radiologist-guided patient education to prepare patients for specific examinations (CT, 28% vs 6%; special procedures, 78% vs 44%) and incident review and analysis (89% vs 47%); however, they required significantly longer access time for MRI examinations (7.00±29.50 vs 3.50±3.50 days), had more yearly incidents of large-volume contrast-medium extravasation (2.75±1.00 vs 1.00±0.75 cases) and blank radiographs (41% vs 8%), lower monthly rates of suboptimal (but interpretable) radiographs (0.00±0.01% vs 0.64±1.84%) and high-risk reminder reporting (0.01±0.16% vs 1.00±1.75%) than local institutions. Our study elucidates the status of patient safety in diagnostic radiology in Taiwan, thereby providing helpful information to improve patient safety guidelines needed for medical imaging in the future. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Vijayasarathi, Arvind; Loehfelm, Thomas; Duszak, Richard; Hawkins, C Matthew
2016-11-01
Patients are increasingly seeking online information regarding their health and their health care providers. Concurrently, more patients are accessing their electronic medical records, including their radiology reports, via online portals. Thus, this study aims to characterize what patients find when they search for radiologists online. All Medicare-participating U.S. radiologists were identified using the Physician Compare National Downloadable File dataset obtained from the Centers for Medicare & Medicaid Services (CMS). Using a custom application, the top 10 Google search results for each radiologist in the national dataset were retrieved, and 90.5% of website domains with more than one occurrence were categorized as follows: physician or institution controlled, third party-controlled physician information systems, social media, or other. Aggregate and subgroup analyses were performed. Of all U.S. health care providers recognized by CMS, 30,601 self-identified as radiologists. There was at least one search result for 30,600 radiologists (99.997%), for a total of 305,795 websites. Of all the domains, 69.8% were third party-controlled physician information systems, 17.7% were physician or institution controlled, 1.0% were social media platforms, 2.1% were other, and 9.5% were not classified. Nine of the top 10 most commonly encountered domains were commercially controlled third-party physician information systems. Most U.S. radiologists lack self-controlled online content within the first page of Google search results. Opportunities exist for individual radiologists, radiology groups, academic departments, and professional societies to amend their online presence, control the content patients discover, and improve the visibility of the field at large.
Tuberculous temporal brain abscess mimicking otogenic pyogenic abscess.
Muzumdar, D; Balasubramaniam, S; Melkundi, S
2009-01-01
Tuberculous brain abscess is a rare manifestation of central nervous system tuberculosis. We report the case of a tuberculous temporal lobe abscess in a 14-year-old female child that mimicked an otogenic pyogenic brain abscess. The patient had no prior history of tuberculosis. She had chronic otitis media and presented with signs of raised intracranial tension. Radiological imaging was suggestive of an acute pyogenic left temporal lobe abscess. A left temporal craniotomy was performed and the abscess was completely excised. Histological examination was consistent with a chronic abscess, and bacterial cultures were negative. A left radical mastoidectomy was also carried out. However, she presented with repeated abscess formation at the same site over the next 8 weeks, which was refractory to surgical therapy and broad-spectrum antibiotic administration. Furthermore, the purulent exudate showed strong positivity in the PCR test for tubercular bacilli. After administration of antituberculous treatment, she showed gradual clinical and radiological improvement. At follow-up after 2 years, she is asymptomatic. CT imaging at 2 years showed total resolution of abscess. Tuberculous abscess in the temporal lobe following otogenic infection has not been reported in the pediatric population. Although rare, the possibility of tuberculous etiology should be borne in mind as a differential diagnosis of acute abscess of otogenic origin, especially in endemic areas where the incidence of chronic otitis media as well as tuberculosis is high. The pathogenesis and treatment of tuberculous brain abscess in children is reviewed in light of the current literature on the subject. Copyright 2009 S. Karger AG, Basel.
Optical memory effect from polarized Laguerre-Gaussian light beam in light-scattering turbid media
NASA Astrophysics Data System (ADS)
Shumyatsky, Pavel; Milione, Giovanni; Alfano, Robert R.
2014-06-01
Propagation effects of polarized Laguerre-Gaussian light with different orbital angular momentum (L) in turbid media are described. The optical memory effect in scattering media consisting of small and large size (compared to the wavelength) scatterers is investigated for scattered polarized light. Imaging using polarized laser modes with a varying orbital strength L-parameter was performed. The backscattered image quality (contrast) was enhanced by more than an order of magnitude using circularly polarized light when the concentration of scatterers was close to invisibility of the object.
TDAAPS 2: Acoustic Wave Propagation in Attenuative Moving Media
DOE Office of Scientific and Technical Information (OSTI.GOV)
Preston, Leiph A.
This report outlines recent enhancements to the TDAAPS algorithm first described by Symons et al., 2005. One of the primary additions to the code is the ability to specify an attenuative media using standard linear fluid mechanisms to match reasonably general frequency versus loss curves, including common frequency versus loss curves for the atmosphere and seawater. Other improvements that will be described are the addition of improved numerical boundary conditions via various forms of Perfectly Matched Layers, enhanced accuracy near high contrast media interfaces, and improved physics options.
Experimental verification of ‘waveguide’ plasmonics
NASA Astrophysics Data System (ADS)
Prudêncio, Filipa R.; Costa, Jorge R.; Fernandes, Carlos A.; Engheta, Nader; Silveirinha, Mário G.
2017-12-01
Surface plasmons polaritons are collective excitations of an electron gas that occur at an interface between negative-ɛ and positive-ɛ media. Here, we report the experimental observation of such surface waves using simple waveguide metamaterials filled only with available positive-ɛ media at microwave frequencies. In contrast to optical designs, in our setup the propagation length of the surface plasmons can be rather long as low loss conventional dielectrics are chosen to avoid typical losses from negative-ɛ media. Plasmonic phenomena have potential applications in enhancing light-matter interactions, implementing nanoscale photonic circuits and integrated photonics.
The influence of contrast media on kidney function in patients with stable coronary artery disease.
Reuter, Simon Bertram; Harutyunyan, Marina; Mygind, Naja Dam; Jørgensen, Erik; Kastrup, Jens
2014-08-01
To investigate the incidence of contrast media-induced nephropathy (CIN) in patients with stable coronary artery disease (CAD) referred for elective coronary intervention following hydration routines. The reversibility of CIN was followed in a 6 month-period. A total of 447 patients referred for elective coronary intervention due to suspected CAD were included. Blood samples were collected before and 24 h after intervention and medical records were obtained. Patients had no drinking fluid restrictions and were routinely treated with a 1000 ml saline infusion. All patients were invited to a 6-month examination and collection of blood samples. A total of 19 patients (4.3%) developed CIN. CIN patients had a pre-investigation higher estimated glomerular filtration rate (eGRF), lower level of kidney failure and lower creatinine level than non-CIN patients. Kidney function was not normalized in CIN patients 6 months after the intervention. Two patients still met the definition of CIN. With no restriction in fluid intake and supplementary infusion of saline, only a few patients with stable CAD developed early indications of CIN during elective coronary interventions. Kidney function and the amount of contrast media used was not a predictor of CIN development. The induced CIN was not completely normalized in a 6-month follow-up period.
Ogawa, Masami; Kawaguchi, Yoshiaki; Kawashima, Yohei; Mizukami, Hajime; Maruno, Atsuko; Ito, Hiroyuki; Mine, Tetsuya
2013-09-20
Pancreatitis is the most common and serious complication of endoscopic retrograde cholangiopancreatography (ERCP). Several studies have compared contrast media (CM) with different osmolalities, but the results are conflicting. We conducted this study to clarify the difference between 2 CM used in ERCP. Five hundred and seventy-six patients were examined by using ERCP in our hospital during 2010. Out of these, 56 patients were enrolled in this study. We investigated the incidence of post ERCP pancreatitis (PEP) and hyperamylasemia. Serum amylase levels were compared in the 2 groups. Twenty-seven patients were treated with iodixanol and 29 with diatrizoate meglumine Na. The rate of PEP in the diatrizoate meglumine Na group and iodixanol group was 0% (0/29) and 7.4% (2/27), respectively (P = 0.228). The rate of hyperamylasemia was 10.3% (3/29) and 14.8% (4/27), respectively (P = 0.70). There were no significant differences between two groups for amylase levels pre-procedure (P = 0.082), 3 h post procedure (P = 0.744), or next morning (P = 0.265). There were no significant differences in the rates of PEP or hyperamylasemia between CMs in ERCP. We believe it is unnecessary to use the more expensive low osmolality CM in ERCP to prevent PEP.
[Contribution of X-ray computed tomography in the evaluation of kidney performance].
Lemoine, Sandrine; Rognant, Nicolas; Collet-Benzaquen, Diane; Juillard, Laurent
2012-07-01
X-ray computer assisted tomography scanner is an imaging method based on the use of X-ray attenuation in tissue. This attenuation is proportional to the density of the tissue (without or after contrast media injection) in each pixel image of the image. Spiral scanner, the electron beam computed tomography (EBCT) scanner and multidetector computed tomography scanner allow renal anatomical measurements, such as cortical and medullary volume, but also the measurement of renal functional parameters, such as regional renal perfusion, renal blood flow and glomerular filtration rate. These functional parameters are extracted from the modeling of the kinetics of the contrast media concentration in the vascular space and the renal tissue, using two main mathematical models (the gamma variate model and the Patlak model). Renal functional imaging allows measuring quantitative parameters on each kidney separately, in a non-invasive manner, providing significant opportunities in nephrology, both for experimental and clinical studies. However, this method uses contrast media that may alter renal function, thus limiting its use in patients with chronic renal failure. Moreover, the increase irradiation delivered to the patient with multi detector computed tomography (MDCT) should be considered. Copyright © 2011 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.
Netherland, Julie; Hansen, Helena B.
2016-01-01
The past decade in the U.S. has been marked by a media fascination with the white prescription opioid cum heroin user. In this paper, we contrast media coverage of white non-medical opioid users with that of black and brown heroin users to show how divergent representations lead to different public and policy responses. A content analysis of 100 popular press articles from 2001 and 2011 in which half describe heroin users and half describe prescription opioid users revealed a consistent contrast between criminalized urban black and Latino heroin injectors with sympathetic portrayals of suburban white prescription opioid users. Media coverage of the suburban and rural opioid “epidemic” of the 2000s helped draw a symbolic, and then legal, distinction between (urban) heroin addiction and (suburban and rural) prescription opioid addiction that is reminiscent of the legal distinction between crack cocaine and powder cocaine of the 1980s and 90s. This distinction reinforces the racialized deployment of the War on Drugs and is sustained by the lack of explicit discussion of race in the service of “color blind ideology.” We suggest potential correctives to these racially divergent patterns, in the form of socially responsible media practices and of clinical engagement with public policy. PMID:27272904
Martí-Bonmatí, L; Martí-Bonmatí, E
The Spanish Agency for Drugs and Healthcare Products (AEMPS), based on the recommendations of the European Committee for Risk Assessment in Pharmacovigilance, established on 13 March 2017 that linear gadolinium-based MR contrast media, such as MultiHance, Omniscan, Magnevist (currently not marketed) and Optimark (no longer marketed in Spain), the clinical benefits do not outweigh the potential risks derived from their use. AEMPS recommends to suspend its marketing for general use based on the retention of these compounds in the brain. On the other hand, the AEMPS justifies the maintenance of Primovist and MultiHance for liver studies, and Magnevist of intra-articular administration (not commercialized in Spain), and justified the almost exclusive use of macrocyclic structure contrasts (Gadovist, ProHance and Dotarem). However, this retention is known to be different for each of the contrast media. All existing gadolinium contrasts agents have a distribution phase with tissue retention, due to a very slow exchange, in the interstitium of bone, skin, kidney, brain and other organs. The existence of histological effects or clinical symptoms associated with the accumulation of these trace amounts of gadolinium has not been demonstrated. The major toxicological concern with these contrast agents is related to nephrogenic systemic fibrosis (NSF). Since the safety profiles are mainly related to the interstitial retention space in the tissues, it does not seem justified to actually exclude contrast media that do not have cases related to the NSF. Based on all of this, we disagree with the latest AEMPS recommendation suggesting the marketing stoppage of linear agents without considering the individual retention profiles. This recommendation is not based neither on the data nor existing knowledge about the retention, relaxivity and clinical efficiency of the Gd compounds. It is therefore necessary to carry out prospective studies on the histological and clinical relevance of these organic Gd deposits. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Kendrick, Daniel E; Allemang, Matthew T; Gosling, Andre F; Nagavalli, Anil; Kim, Ann H; Nishino, Setsu; Parikh, Sahil A; Bezerra, Hiram G; Kashyap, Vikram S
2016-10-01
To examine the hypothesis that alternative flush media could be used for lower extremity optical coherence tomography (OCT) imaging in long lesions that would normally require excessive use of contrast. The OPTical Imaging Measurement of Intravascular Solution Efficacy (OPTIMISE) trial was a single-center, prospective study (ClinicalTrials.gov identifier NCT01743872) that enrolled 23 patients (mean age 68±11 years; 14 men) undergoing endovascular intervention involving the superficial femoral artery. Four flush media (heparinized saline, dextran, carbon dioxide, and contrast) were used in succession in random order for each image pullback. Quality was defined as ≥270° visualization of vessel wall layers from each axial image. Mean proportions (± standard deviation) of image quality for each flush medium were assessed using 1-way analysis of variance and are reported with the 95% confidence intervals (CI). Four OCT catheters failed, leaving 19 patients who completed the OCT imaging protocol; from this cohort, 51 highest quality runs were selected for analysis. Average vessel diameter was 3.99±1.01 mm. OCT imaging allowed 10- to 15-μm resolution of the lumen border, with diminishing quality as vessel diameter increased. Plaque characterization revealed fibrotic lesions. Mean proportions of image quality were dextran 87.2%±12% (95% CI 0.81 to 0.94), heparinized saline 74.3%±24.8% (95% CI 0.66 to 0.93), contrast 70.1%±30.5% (95% CI 0.52 to 0.88), and carbon dioxide 10.0%±10.4% (95% CI 0.00 to 0.26). Dextran, saline, and contrast provided better quality than carbon dioxide (p<0.001). OCT is feasible in peripheral vessels <5 mm in diameter. Dextran or saline flush media can allow lesion characterization, avoiding iodinated contrast. Carbon dioxide is inadequate for peripheral OCT imaging. Axial imaging may aid in enhancing durability of peripheral endovascular interventions. © The Author(s) 2016.
Minghetti, Matteo; Schirmer, Kristin
2016-12-01
To understand conditions affecting bioavailability and toxicity of citrate-coated silver nanoparticles (cit-AgNP) and dissolved silver at the luminal enterocyte interface, we exposed rainbow trout (Oncorhynchus mykiss) gut cells (RTgutGC) in media of contrasting composition: two amino acid-containing media, one of which was supplemented with proteins, as can be expected during digestion; and two protein and amino acid-free media contrasting low and high chloride content, as can be expected in the lumen of fish adapting to freshwater or seawater, respectively. Dose-response curves were generated measuring cell metabolic activity, membrane and lysosome integrity over a period of 72 hours. Then, nontoxic doses were applied and total silver accumulation, metallothionein and glutathione reductase mRNA levels were determined. The presence of proteins stabilized cit-AgNP keeping them in suspension. Conversely, in protein-free media, cit-AgNP agglomerated and settled, resulting in higher cellular accumulation of silver and toxicity. Chloride concentrations in exposure media modulated the toxicity of AgNO 3 but not of cit-AgNP. Moreover, while amino acid-containing media are protective against AgNO 3 , likely due to the formation of thiolate complexes, they are only partially protective against cit-AgNP. Viability assays indicated that lysosomes are targets of cit-AgNP, supporting the hypothesis that cit-AgNP exert toxicity intracellularly. Metallothionein, a sensor of metal bioavailability, was induced by cit-AgNP in high chloride medium but not in low chloride medium, indicating that chloride might have a role in mobilizing silver from intercellular vesicles. Overall, this study shows that AgNP bioavailability and toxicity in the intestine is linked to its luminal content.
X-ray phase-contrast imaging of the breast—advances towards clinical implementation
Herzen, J; Willner, M; Grandl, S; Scherer, K; Bamberg, F; Reiser, M F; Pfeiffer, F; Hellerhoff, K
2014-01-01
Breast cancer constitutes about one-quarter of all cancers and is the leading cause of cancer death in women. To reduce breast cancer mortality, mammographic screening programmes have been implemented in many Western countries. However, these programmes remain controversial because of the associated radiation exposure and the need for improvement in terms of diagnostic accuracy. Phase-contrast imaging is a new X-ray-based technology that has been shown to provide enhanced soft-tissue contrast and improved visualization of cancerous structures. Furthermore, there is some indication that these improvements of image quality can be maintained at reduced radiation doses. Thus, X-ray phase-contrast mammography may significantly contribute to advancements in early breast cancer diagnosis. Feasibility studies of X-ray phase-contrast breast CT have provided images that allow resolution of the fine structure of tissue that can otherwise only be obtained by histology. This implies that X-ray phase-contrast imaging may also lead to the development of entirely new (micro-) radiological applications. This review provides a brief overview of the physical characteristics of this new technology and describes recent developments towards clinical implementation of X-ray phase-contrast imaging of the breast. PMID:24452106
Incidence of acute otitis media in infants in a general practice
Ross, Alistair K.; Croft, Peter R.; Collins, Mike
1988-01-01
A 12-month study of the incidence of acute otitis media in children under three years of age in an urban practice of 10 000 patients showed that acute otitis media accounted for one in 10 of all episodes of illness presented. In contrast to findings in Scandinavia and the USA the incidence of acute otitis media in the first year of life (11.5%) was lower than in the second year (28.6%). The study included a number of children in their third year and the incidence in this group was higher still (30.8%). The problems of defining acceptable diagnostic criteria for acute otitis media, and the relation of these diagnostic criteria to the differences in our results compared with previous studies are discussed. PMID:3204570
Spontaneous soft tissue hematomas.
Dohan, A; Darnige, L; Sapoval, M; Pellerin, O
2015-01-01
Spontaneous muscle hematomas are a common and serious complication of anticoagulant treatment. The incidence of this event has increased along with the rise in the number of patients receiving anticoagulants. Radiological management is both diagnostic and interventional. Computed tomography angiography (CTA) is the main tool for the detection of hemorrhage to obtain a positive, topographic diagnosis and determine the severity. Detection of an active leak of contrast material during the arterial or venous phase is an indication for the use of arterial embolization. In addition, the interventional radiological procedure can be planned with CTA. Arterial embolization of the pedicles that are the source of the bleeding is an effective technique. The rate of technical and clinical success is 90% and 86%, respectively. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
A comparison of the palatability of flavored oral contrasts.
Arya, Rajiv; Hansen, Allison; Taira, Breena R; Packy, Theodore; Singer, Adam J
2009-09-01
The aim of this study was to compare the taste of computed tomography (CT) oral contrast diluted with various flavored drinks. We performed a prospective, blinded, controlled trial in healthy adult volunteers. Subjects were assigned to ingest four 250-mL aliquots of oral contrast media diluted in water, Crystal Light Lemonade (Kraft Food, Northfield, Ill), Tropical Punch Kool-Aid (Kraft Food), and Tropicana orange juice (Pepsi Bottling Company, Sommers, NY) in random order; and the taste of the solution was measured with a 100-mm visual analogue scale and 5-point Likert scale from very worst to best. Between-group comparison of the taste scores was performed with repeated-measures analysis of variance and pairwise t tests. The study had 80% power to detect an effect size 0.75 SDs. There were 23 subjects; mean (SD) age was 33 (7.7) and 30% were female. The mean (SD) taste scores were water 12 (5), lemonade 37 (21), Kool-Aid 44 (20), and orange juice 40 (20) (P < .05). The proportion of subjects completely ingesting the contrast in water (65%) was significantly less than that with other 3 study solutions (100% each, P < .001). Dilution of oral contrast media with lemonade, fruit punch, or orange juice is tastier than with water. The choice of the specific juice used to dilute the oral contrast should be individualized based on patient preferences and availability.
Effect of contrast media on megavoltage photon beam dosimetry.
Rankine, Ashley W; Lanzon, Peter J; Spry, Nigel A
2008-01-01
The purpose of this study was to quantify changes in photon beam dosimetry caused by using contrast media during computed tomography (CT) simulation and determine if the resulting changes are clinically significant. The effect of contrast on dosimetry was first examined for a single 6-MV photon beam incident on a plane phantom with a structure of varying electron densities (rho(e)) and thickness. Patient studies were then undertaken in which CT data sets were collected with and without contrast for 6 typical patients. Three patients received IV contrast (Optiray-240) only and 3 received IV plus oral (Gastrograffin) contrast. Each patient was planned using conformal multifield techniques in accordance with the department standards. Two methods were used to compare the effect of contrast on dosimetry for each patient. The phantom analysis showed that the change in dose at the isocenter for a single 10 x 10 cm2 6-MV photon beam traversing 10 cm of a contrast-enhanced structure with rho(e) 1.22 was 7.0% (1.22 was the highest average rho(e) observed in the patient data). As a result of using contrast, increases in rho(e) were observed in structures for the 6 patients studied. Consequently, when using contrast-enhanced CT data for multifield planning, increases in dose at the isocenter and in critical structures were observed up to 2.1% and 2.5%, respectively. Planning on contrast-enhanced CT images may result in an increase in dose of up to 2.1% at the isocenter, which would generally be regarded as clinically insignificant. If, however, a critical organ is in close proximity to the planning target volume (PTV) and is planned to receive its maximum allowable dose, planning on contrast-enhanced CT images may result in that organ receiving dose beyond the recommended tolerance. In these instances, pre-contrast CT data should be used for dosimetry.
Srinivasan, Velusamy; Gertz, Robert E; Shewmaker, Patricia L; Patrick, Sarah; Chitnis, Amit S; O'Connell, Heather; Benowitz, Isaac; Patel, Priti; Guh, Alice Y; Noble-Wang, Judith; Turabelidze, George; Beall, Bernard
2012-01-01
We recently investigated three cases of bacterial meningitis that were reported from a midwestern radiology clinic where facemasks were not worn during spinal injection of contrast agent during myelography procedures. Using pulsed field gel electrophoresis we linked a case strain of S. salivarius to an oral specimen of a radiology physician assistant (RPA). We also used a real-time PCR assay to detect S. salivarius DNA within a culture-negative cerebrospinal fluid (CSF) specimen. Here we extend this investigation through using a nested PCR/sequencing strategy to link the culture-negative CSF specimen to the case strain. We also provide validation of the real-time PCR assay used, demonstrating that it is not solely specific for Streptococcus salivarius, but is also highly sensitive for detection of the closely related oral species Streptococcus vestibularis. Through using multilocus sequence typing and 16S rDNA sequencing we further strengthen the link between the CSF case isolate and the RPA carriage isolate. We also demonstrate that the newly characterized strains from this study are distinct from previously characterized S. salivarius strains associated with carriage and meningitis.
Sharma, Samin K
2008-05-01
Over 20 years have passed since the introduction of the tri-iodinated low-osmolar nonionic contrast agents such as iopamidol, iohexol, ioversol and iopromide. During this time, most cardiology practices have switched to these nonionic agents to avoid the nuisance side effects and cardiac adverse events associated with the older ionic contrast agents. Although the improved tolerability of the nonionic agents is generally attributed to their decreased osmolality (approximately half that of the older ionic contrast agents), in fact, these contrast agents also differ from the older agents in their ionicity, viscosity and direct chemotoxicity. The impact of these properties on safety, together with cost differences, should be considered when selecting a contrast agent.
Desoubeaux, Guillaume; Chaussade, Hélène; Thellier, Marc; Poussing, Sophie; Bastides, Frédéric; Bailly, Eric; Lanotte, Philippe; Alison, Daniel; Brunereau, Laurent; Bernard, Louis; Chandenier, Jacques
2014-01-01
We report a rare case of amebiasis generating 19 large liver abscesses. Such a quantity of abscesses is rare, especially when occurring in a young casual traveler without any immunodeficiency disorders. A possible co-infection was excluded. By contrast, the amebic etiology was confirmed by means of serology and real-time PCR.
Model-Free Stochastic Localization of CBRN Releases
2013-01-01
Ioannis Ch. Paschalidis,‡ Senior Member, IEEE Abstract—We present a novel two-stage methodology for locating a Chemical, Biological, Radiological, or...Nuclear (CBRN) source in an urban area using a network of sensors. In contrast to earlier work, our approach does not solve an inverse dispersion problem...but relies on data obtained from a simulation of the CBRN dispersion to obtain probabilistic descriptors of sensor measurements under a variety of CBRN
An atlas of radiological interpretation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calder, J.F.; Chessell, G.
1988-01-01
This book is concerned with pathologic entities and their impact on the skeleton. The book is divided into nine chapters. After a discussion of normal anatomic features, the authors discuss trauma, avascular necrosis and osteochondritis, bone infections, diseases of the joints, bone tumors, reticuloses and hemopoietic disorders, endocrine and metabolic bone diseases, and congenital abnormalities. A line drawing accompanies every radiograph to contrast the pathologic findings with the normal anatomic features.
Scarabelli, Stefania; Cripps, Peter; Rioja, Eva; Alderson, Briony
2016-09-01
To evaluate incidences of adverse reaction after the administration of contrast media. Retrospective observational study. Animals included 356 dogs and 58 cats receiving non-ionic iodinated contrast agents, and 425 dogs and 49 cats receiving gadolinium-based contrast agents. Anaesthesia records of dogs and cats receiving intravenous (IV) gadobutrol for magnetic resonance imaging (MRI) or IV iohexol for computed tomography (CT) were reviewed. Changes in pulse rate, respiratory rate and mean arterial pressure at 5 minutes after administration of the contrast medium were evaluated. Changes of 10-20% were considered mild, those of >20% moderate, and reactions that required immediate treatment were considered severe. Associations of sex, age and weight with contrast reaction were investigated using logistic regression. Differences in the incidences of reactions to CT and MRI contrast media were examined with chi-squared tests. A p-value of <0.05 was considered to indicate statistical significance. Of cats receiving iohexol, eight (13.8%) had mild and 10 (17.2%) had moderate reactions. Of cats receiving gadobutrol, six (12.2%) had mild and six (12.2%) had moderate reactions. No cats had severe reactions and the risk for reaction was not associated with type of medium, age, weight or sex (p > 0.2). Of dogs receiving iohexol, 64 (18.0%) had mild, 65 (18.3%) had moderate and three (0.8%) had severe reactions. Of dogs receiving gadobutrol, 42 (9.9%) had mild, 87 (20.5%) had moderate and one (0.2%) had a severe reaction. When dogs receiving iohexol were compared with those receiving gadobutrol, the odds ratio of a moderate reaction was 2.0 (95% confidence interval 1.34-3.10; p = 0.001). These estimates did not change substantially after adjustment for age, weight and sex. Severe reactions to iohexol and gadobutrol are rare in dogs and cats; moderate reactions are more likely with iohexol than with gadobutrol. © 2015 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.