Lee, Ming-Che; Chuang, Kei-Shih; Hsu, Tien-Cheng; Lee, Chien-Ding
2016-11-01
Collection of radiation dose derived from radiological examination is necessary not only for radiation protection, but also for fulfillment of structured reports. However, the material regarding of radiation dose cannot be directly utilized by the Radiological Information System (RIS) since it is generated and only stored in the Picture Archiving and Communication System (PACS). In this paper, an integration reporting module is proposed to facilitate handling of dose information and structured reporting by providing two functionalities. First, a gateway is established to automatically collect the related information from PACS for further analyzing and monitoring the accumulated radiation. Second, the designated structured reporting patterns with corresponding radiation dose measurements can be acquired by radiologists as necessary. In the design, the radiation dose collection gateway and the well-established pattern are collocated to achieve that there is no need to do manual entry for structured reporting, thus increasing productivity and medical quality.
ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology.
Khong, P-L; Ringertz, H; Donoghue, V; Frush, D; Rehani, M; Appelgate, K; Sanchez, R
2013-04-01
Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities - radiography and fluoroscopy, interventional radiology, and computed tomography - are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation, use of protective shielding, optimisation of exposure factors, use of pulsed fluoroscopy, limiting fluoroscopy time, etc. Major paediatric interventional procedures should be performed by experienced paediatric interventional operators, and a second, specific level of training in radiological protection is desirable (in some countries, this is mandatory). For computed tomography, dose reduction should be optimised by the adjustment of scan parameters (such as mA, kVp, and pitch) according to patient weight or age, region scanned, and study indication (e.g. images with greater noise should be accepted if they are of sufficient diagnostic quality). Other strategies include restricting multiphase examination protocols, avoiding overlapping of scan regions, and only scanning the area in question. Up-to-date dose reduction technology such as tube current modulation, organ-based dose modulation, auto kV technology, and iterative reconstruction should be utilised when appropriate. It is anticipated that this publication will assist institutions in encouraging the standardisation of procedures, and that it may help increase awareness and ultimately improve practices for the benefit of patients. Copyright © 2012. Published by Elsevier Ltd.
Gopalakrishnan, V; Baskaran, R; Venkatraman, B
2016-08-01
A decision support system (DSS) is implemented in Radiological Safety Division, Indira Gandhi Centre for Atomic Research for providing guidance for emergency decision making in case of an inadvertent nuclear accident. Real time gamma dose rate measurement around the stack is used for estimating the radioactive release rate (source term) by using inverse calculation. Wireless gamma dose logging network is designed, implemented, and installed around the Madras Atomic Power Station reactor stack to continuously acquire the environmental gamma dose rate and the details are presented in the paper. The network uses XBee-Pro wireless modules and PSoC controller for wireless interfacing, and the data are logged at the base station. A LabView based program is developed to receive the data, display it on the Google Map, plot the data over the time scale, and register the data in a file to share with DSS software. The DSS at the base station evaluates the real time source term to assess radiation impact.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gopalakrishnan, V.; Baskaran, R.; Venkatraman, B.
A decision support system (DSS) is implemented in Radiological Safety Division, Indira Gandhi Centre for Atomic Research for providing guidance for emergency decision making in case of an inadvertent nuclear accident. Real time gamma dose rate measurement around the stack is used for estimating the radioactive release rate (source term) by using inverse calculation. Wireless gamma dose logging network is designed, implemented, and installed around the Madras Atomic Power Station reactor stack to continuously acquire the environmental gamma dose rate and the details are presented in the paper. The network uses XBee–Pro wireless modules and PSoC controller for wireless interfacing,more » and the data are logged at the base station. A LabView based program is developed to receive the data, display it on the Google Map, plot the data over the time scale, and register the data in a file to share with DSS software. The DSS at the base station evaluates the real time source term to assess radiation impact.« less
A New Therapeutic Paradigm for Breast Cancer Exploiting Low Dose Estrogen-Induced Apoptosis
2009-09-01
binds to the Hsp90, Hsp27 , and c-Fos promoters constitutively and modulates their expression. Cell Stress Chaperones, 12: 283-290...C. Yang, Radiological health risks for exploratory class missions in space. Acta Astronaut . 23, 227–231 (1991). 10. V. M. Petrov, Solar cosmic rays
Rancilio, Nicholas J; Custead, Michelle R; Poulson, Jean M
2016-09-01
A 5-year-old spayed female Shih Tzu was referred for evaluation of a nasal transitional carcinoma. A total lifetime dose of 117 Gy was delivered to the intranasal mass in three courses over nearly 2 years using fractionated intensity modulated radiation therapy (IMRT) to spare normal tissues. Clinically significant late normal tissue side effects were limited to bilaterally diminished tear production. The patient died of metastatic disease progression 694 days after completion of radiation therapy course 1. This case demonstrates that retreatment with radiation therapy to high lifetime doses for recurrent local disease may be well tolerated with IMRT. © 2016 American College of Veterinary Radiology.
Occupational dose in interventional radiology procedures.
Chida, Koichi; Kaga, Yuji; Haga, Yoshihiro; Kataoka, Nozomi; Kumasaka, Eriko; Meguro, Taiichiro; Zuguchi, Masayuki
2013-01-01
Interventional radiology tends to involve long procedures (i.e., long fluoroscopic times). Therefore, radiation protection for interventional radiology staff is an important issue. This study describes the occupational radiation dose for interventional radiology staff, especially nurses, to clarify the present annual dose level for interventional radiology nurses. We compared the annual occupational dose (effective dose and dose equivalent) among interventional radiology staff in a hospital where 6606 catheterization procedures are performed annually. The annual occupational doses of 18 physicians, seven nurses, and eight radiologic technologists were recorded using two monitoring badges, one worn over and one under their lead aprons. The annual mean ± SD effective dose (range) to the physicians, nurses, and radiologic technologists using two badges was 3.00 ± 1.50 (0.84-6.17), 1.34 ± 0.55 (0.70-2.20), and 0.60 ± 0.48 (0.02-1.43) mSv/y, respectively. Similarly, the annual mean ± SD dose equivalent range was 19.84 ± 12.45 (7.0-48.5), 4.73 ± 0.72 (3.9-6.2), and 1.30 ± 1.00 (0.2-2.7) mSv/y, respectively. The mean ± SD effective dose for the physicians was 1.02 ± 0.74 and 3.00 ± 1.50 mSv/y for the one- and two-badge methods, respectively (p < 0.001). Similarly, the mean ± SD effective dose for the nurses (p = 0.186) and radiologic technologists (p = 0.726) tended to be lower using the one-badge method. The annual occupational dose for interventional radiology staff was in the order physicians > nurses > radiologic technologists. The occupational dose determined using one badge under the apron was far lower than the dose obtained with two badges in both physicians and nonphysicians. To evaluate the occupational dose correctly, we recommend use of two monitoring badges to evaluate interventional radiology nurses as well as physicians.
Hansmann, Jan; Henzler, Thomas; Gaba, Ron C; Morelli, John N
2017-01-01
We aimed to quantify and compare awareness regarding radiation dose reduction within the interventional radiology and diagnostic radiology communities. Abstracts accepted to the annual meetings of the Society of Interventional Radiology (SIR), the Cardiovascular and Interventional Radiological Society of Europe (CIRSE), the Radiological Society of North America (RSNA), and the European Congress of Radiology (ECR) between 2005 and 2015 were analyzed using the search terms "interventional/computed tomography" and "radiation dose/radiation dose reduction." A PubMed query using the above-mentioned search terms for the years of 2005-2015 was performed. Between 2005 and 2015, a total of 14 520 abstracts (mean, 660±297 abstracts) and 80 614 abstracts (mean, 3664±1025 abstracts) were presented at interventional and diagnostic radiology meetings, respectively. Significantly fewer abstracts related to radiation dose were presented at the interventional radiology meetings compared with the diagnostic radiology meetings (162 abstracts [1% of total] vs. 2706 [3% of total]; P < 0.001). On average 15±7 interventional radiology abstracts (range, 6-27) and 246±105 diagnostic radiology abstracts (range, 112-389) pertaining to radiation dose were presented at each meeting. The PubMed query revealed an average of 124±39 publications (range, 79-187) and 1205±307 publications (range, 829-1672) related to interventional and diagnostic radiology dose reduction per year, respectively (P < 0.001). The observed increase in the number of abstracts regarding radiation dose reduction in the interventional radiology community over the past 10 years has not mirrored the increased volume seen within diagnostic radiology, suggesting that increased education and discussion about this topic may be warranted.
Hansmann, Jan; Henzler, Thomas; Gaba, Ron C.; Morelli, John N.
2017-01-01
PURPOSE We aimed to quantify and compare awareness regarding radiation dose reduction within the interventional radiology and diagnostic radiology communities. METHODS Abstracts accepted to the annual meetings of the Society of Interventional Radiology (SIR), the Cardiovascular and Interventional Radiological Society of Europe (CIRSE), the Radiological Society of North America (RSNA), and the European Congress of Radiology (ECR) between 2005 and 2015 were analyzed using the search terms “interventional/computed tomography” and “radiation dose/radiation dose reduction.” A PubMed query using the above-mentioned search terms for the years of 2005–2015 was performed. RESULTS Between 2005 and 2015, a total of 14 520 abstracts (mean, 660±297 abstracts) and 80 614 abstracts (mean, 3664±1025 abstracts) were presented at interventional and diagnostic radiology meetings, respectively. Significantly fewer abstracts related to radiation dose were presented at the interventional radiology meetings compared with the diagnostic radiology meetings (162 abstracts [1% of total] vs. 2706 [3% of total]; P < 0.001). On average 15±7 interventional radiology abstracts (range, 6–27) and 246±105 diagnostic radiology abstracts (range, 112–389) pertaining to radiation dose were presented at each meeting. The PubMed query revealed an average of 124±39 publications (range, 79–187) and 1205±307 publications (range, 829–1672) related to interventional and diagnostic radiology dose reduction per year, respectively (P < 0.001). CONCLUSION The observed increase in the number of abstracts regarding radiation dose reduction in the interventional radiology community over the past 10 years has not mirrored the increased volume seen within diagnostic radiology, suggesting that increased education and discussion about this topic may be warranted. PMID:28287072
Dolera, Mario; Malfassi, Luca; Marcarini, Silvia; Mazza, Giovanni; Carrara, Nancy; Pavesi, Simone; Sala, Massimo; Finesso, Sara; Urso, Gaetano
2018-06-08
The aim of this prospective pilot study was to evaluate the feasibility and effectiveness of curative intent high dose hypofractionated frameless volumetric modulated arc radiotherapy for treatment of canine trigeminal peripheral nerve sheath tumors. Client-owned dogs with a presumptive imaging-based diagnosis of trigeminal peripheral nerve sheath tumor were recruited for the study during the period of February 2010 to December 2013. Seven dogs were enrolled and treated with high dose hypofractionated volumetric modulated arc radiotherapy delivered by a 6 MV linear accelerator equipped with a micro-multileaf beam collimator. The plans were computed using a Monte Carlo algorithm with a prescription dose of 37 Gy delivered in five fractions on alternate days. Overall survival was estimated using a Kaplan-Meier curve analysis. Magnetic resonance imaging (MRI) follow-up examinations revealed complete response in one dog, partial response in four dogs, and stable disease in two dogs. Median overall survival was 952 days with a 95% confidence interval of 543-1361 days. Volumetric modulated arc radiotherapy was demonstrated to be feasible and effective for trigeminal peripheral nerve sheath tumor treatment in this sample of dogs. The technique required few sedations and spared organs at risk. Even though larger studies are required, these preliminary results supported the use of high dose hypofractionated volumetric modulated arc radiotherapy as an alternative to other treatment modalities. © 2018 American College of Veterinary Radiology.
Murphy, Kevin P; Crush, Lee; O'Malley, Eoin; Daly, Fergus E; O'Tuathaigh, Colm M P; O'Connor, Owen J; Cryan, John F; Maher, Michael M
2014-10-01
To examine the impact that anatomy-focused radiology teaching has on non-examined knowledge regarding radiation safety and radiology as a specialty. First-year undergraduate medical students completed surveys prior to and after undertaking the first-year anatomy programme that incorporates radiological anatomy. Students were asked opinions on preferred learning methodology and tested on understanding of radiology as a specialty and radiation safety. Pre-module and post-module response rates were 93 % (157/168) and 85 % (136/160), respectively. Pre-module and post-module, self-directed learning (SDL) ranked eighth (of 11) for preferred gross-anatomy teaching formats. Correct responses regarding radiologist/radiographer roles varied from 28-94 % on 16 questions with 4/16 significantly improving post-module. Identification of modalities that utilise radiation significantly improved for five of eight modalities post-module but knowledge regarding relative amount of modality-specific radiation use was variable pre-module and post-module. SDL is not favoured as an anatomy teaching method. Exposure of students to a radiological anatomy module delivered by senior clinical radiologists improved basic knowledge regarding ionising radiation use, but there was no improvement in knowledge regarding radiation exposure relative per modality. A possible explanation is that students recall knowledge imparted in didactic lectures but do little reading around the subject when the content is not examined. • Self-directed learning is not favoured as a gross anatomy teaching format amongst medical students. • An imaging anatomy-focused module improved basic knowledge regarding ionising radiation use. • Detailed knowledge of modality-specific radiation exposure remained suboptimal post-module. • Knowledge of roles within a clinical radiology department showed little change post-module.
Lepoire, D; Richmond, P; Cheng, J-J; Kamboj, S; Arnish, J; Chen, S Y; Barr, C; McKenney, C
2008-08-01
As part of the requirement for terminating the licenses of nuclear power plants or other nuclear facilities, license termination plans or decommissioning plans are submitted by the licensee to the U.S. Nuclear Regulatory Commission (NRC) for review and approval. Decommissioning plans generally refer to the decommissioning of nonreactor facilities, while license termination plans specifically refer to the decommissioning of nuclear reactor facilities. To provide a uniform and consistent review of dose modeling aspects of these plans and to address NRC-wide knowledge management issues, the NRC, in 2006, commissioned Argonne National Laboratory to develop a Web-based training course on reviewing radiological dose assessments for license termination. The course, which had first been developed in 2005 to target specific aspects of the review processes for license termination plans and decommissioning plans, evolved from a live classroom course into a Web-based training course in 2006. The objective of the Web-based training course is to train NRC staff members (who have various relevant job functions and are located at headquarters, regional offices, and site locations) to conduct an effective review of dose modeling in accordance with the latest NRC guidance, including NUREG-1757, Volumes 1 and 2. The exact size of the staff population who will receive the training has not yet been accurately determined but will depend on various factors such as the decommissioning activities at the NRC. This Web-based training course is designed to give NRC staff members modern, flexible access to training. To this end, the course is divided into 16 modules: 9 core modules that deal with basic topics, and 7 advanced modules that deal with complex issues or job-specific topics. The core and advanced modules are tailored to various NRC staff members with different job functions. The Web-based system uses the commercially available software Articulate, which incorporates audio, video, and animation in slide presentations and has glossary, document search, and Internet connectivity features. The training course has been implemented on an NRC system that allows staff members to register, select courses, track records, and self-administer quizzes.
Analytical probabilistic proton dose calculation and range uncertainties
NASA Astrophysics Data System (ADS)
Bangert, M.; Hennig, P.; Oelfke, U.
2014-03-01
We introduce the concept of analytical probabilistic modeling (APM) to calculate the mean and the standard deviation of intensity-modulated proton dose distributions under the influence of range uncertainties in closed form. For APM, range uncertainties are modeled with a multivariate Normal distribution p(z) over the radiological depths z. A pencil beam algorithm that parameterizes the proton depth dose d(z) with a weighted superposition of ten Gaussians is used. Hence, the integrals ∫ dz p(z) d(z) and ∫ dz p(z) d(z)2 required for the calculation of the expected value and standard deviation of the dose remain analytically tractable and can be efficiently evaluated. The means μk, widths δk, and weights ωk of the Gaussian components parameterizing the depth dose curves are found with least squares fits for all available proton ranges. We observe less than 0.3% average deviation of the Gaussian parameterizations from the original proton depth dose curves. Consequently, APM yields high accuracy estimates for the expected value and standard deviation of intensity-modulated proton dose distributions for two dimensional test cases. APM can accommodate arbitrary correlation models and account for the different nature of random and systematic errors in fractionated radiation therapy. Beneficial applications of APM in robust planning are feasible.
The Dose Response Relationship for Radiation Carcinogenesis
NASA Astrophysics Data System (ADS)
Hall, Eric
2008-03-01
Recent surveys show that the collective population radiation dose from medical procedures in the U.S. has increased by 750% in the past two decades. It would be impossible to imagine the practice of medicine today without diagnostic and therapeutic radiology, but nevertheless the widespread and rapidly increasing use of a modality which is a known human carcinogen is a cause for concern. To assess the magnitude of the problem it is necessary to establish the shape of the dose response relationship for radiation carcinogenesis. Information on radiation carcinogenesis comes from the A-bomb survivors, from occupationally exposed individuals and from radiotherapy patients. The A-bomb survivor data indicates a linear relationship between dose and the risk of solid cancers up to a dose of about 2.5 Sv. The lowest dose at which there is a significant excess cancer risk is debatable, but it would appear to be between 40 and 100 mSv. Data from the occupation exposure of nuclear workers shows an excess cancer risk at an average dose of 19.4 mSv. At the other end of the dose scale, data on second cancers in radiotherapy patients indicates that cancer risk does not continue to rise as a linear function of dose, but tends towards a plateau of 40 to 60 Gy, delivered in a fractionated regime. These data can be used to estimate the impact of diagnostic radiology at the low dose end of the dose response relationship, and the impact of new radiotherapy modalities at the high end of the dose response relationship. In the case of diagnostic radiology about 90% of the collective population dose comes from procedures (principally CT scans) which involve doses at which there is credible evidence of an excess cancer incidence. While the risk to the individual is small and justified in a symptomatic patient, the same is not true of some screening procedures is asymptomatic individuals, and in any case the huge number of procedures must add up to a potential public health problem. In the case of radiation oncology, modern innovations such as Intensity Modulated Radiation Oncology or Proton Therapy both result in a substantial total-body dose to the patient, which must result in an increased incidence of second cancers. The technology exists to reduce these total body doses and the problem needs to be addressed.
White Paper: Radiological Curriculum for Undergraduate Medical Education in Germany.
Ertl-Wagner, B; Barkhausen, J; Mahnken, A H; Mentzel, H J; Uder, M; Weidemann, J; Stumpp, P
2016-11-01
Purpose: Radiology represents a highly relevant part of undergraduate medical education from preclinical studies to subinternship training. It is therefore important to establish a content base for teaching radiology in German Medical Faculties. Materials and Methods: The German Society of Radiology (DRG) developed a model curriculum for radiological teaching at German medical universities, which is presented in this article. There is also a European model curriculum for undergraduate teaching (U-level curriculum of the European Society of Radiology). In a modular concept, the students shall learn important radiological core principles in the realms of knowledge, skills and competences as well as core scientific competences in the imaging sciences. Results: The curriculum is divided into two modules. Module 1 includes principles of radiation biology, radiation protection and imaging technology, imaging anatomy as well as the risks and side effects of radiological methods, procedures and contrast media. This module is modality-oriented. Module 2 comprises radiological diagnostic decision-making and imaging-based interventional techniques for various disease entities. This module is organ system-oriented. Conclusion: The curriculum is meant as a living document to be amended and revised at regular intervals. The curriculum can be used as a basis for individual curricular development at German Medical Faculties. It can be integrated into traditional or reformed medical teaching curricula. Key Points: • Radiology is an integral and important part of medical education.• The German Society of Radiology (DRG) developed a model curriculum for teaching radiology at German Medical Faculties to help students develop the ability to make medical decisions based on scientific knowledge and act accordingly.• This curriculum can be used for individual curricular development at medical departments. It is divided into two modules with several chapters. Citation Format: • Ertl-Wagner B, Barkhausen J, Mahnken AH et al. White Paper: Radiological Curriculum for Undergraduate Medical Education in Germany. Fortschr Röntgenstr 2016; 188: 1017 - 1023. © Georg Thieme Verlag KG Stuttgart · New York.
Nicolas, Fadia; Wu, Changgong; Bukhari, Salwa; de Toledo, Sonia M.; Li, Hong; Shibata, Masayuki; Azzam, Edouard I.
2015-01-01
The covalent addition of nitric oxide (NO•) onto cysteine thiols, or S-nitrosylation, modulates the activity of key signaling proteins. The dysregulation of normal S-nitrosylation contributes to degenerative conditions and to cancer. To gain insight into the biochemical changes induced by low-dose ionizing radiation, we determined global S-nitrosylation by the “biotin switch” assay coupled with mass spectrometry analyses in organs of C57BL/6J mice exposed to acute 0.1 Gy of 137Cs γ-rays. The dose of radiation was delivered to the whole body in the presence or absence of iopamidol, an iodinated contrast agent used during radiological examinations. To investigate whether similar or distinct nitrosylation patterns are induced following high-dose irradiation, mice were exposed in parallel to acute 4 Gy of 137Cs γ rays. Analysis of modulated S-nitrosothiols (SNO-proteins) in freshly-harvested organs of animals sacrificed 13 days after irradiation revealed radiation dose- and contrast agent-dependent changes. The major results were as follows: (i) iopamidol alone had significant effects on S-nitrosylation in brain, lung and liver; (ii) relative to the control, exposure to 0.1 Gy without iopamidol resulted in statistically-significant SNO changes in proteins that differ in molecular weight in liver, lung, brain and blood plasma; (iii) iopamidol enhanced the decrease in S-nitrosylation induced by 0.1 Gy in brain; (iv) whereas a decrease in S-nitrosylation occurred at 0.1 Gy for proteins of ~50 kDa in brain and for proteins of ~37 kDa in liver, an increase was detected at 4 Gy in both organs; (v) mass spectrometry analyses of nitrosylated proteins in brain revealed differential modulation of SNO proteins (e.g., sodium/potassium-transporting ATPase subunit beta-1; beta tubulins; ADP-ribosylation factor 5) by low- and high-dose irradiation; and (vi) ingenuity pathway analysis identified major signaling networks to be modulated, in particular the neuronal nitric oxide synthase signaling pathway was differentially modulated by low- and high-dose γ-irradiation. PMID:26317069
Nicolas, Fadia; Wu, Changgong; Bukhari, Salwa; de Toledo, Sonia M; Li, Hong; Shibata, Masayuki; Azzam, Edouard I
2015-04-28
The covalent addition of nitric oxide (NO • ) onto cysteine thiols, or S -nitrosylation, modulates the activity of key signaling proteins. The dysregulation of normal S -nitrosylation contributes to degenerative conditions and to cancer. To gain insight into the biochemical changes induced by low-dose ionizing radiation, we determined global S -nitrosylation by the "biotin switch" assay coupled with mass spectrometry analyses in organs of C57BL/6J mice exposed to acute 0.1 Gy of 137 Cs γ-rays. The dose of radiation was delivered to the whole body in the presence or absence of iopamidol, an iodinated contrast agent used during radiological examinations. To investigate whether similar or distinct nitrosylation patterns are induced following high-dose irradiation, mice were exposed in parallel to acute 4 Gy of 137 Cs γ rays. Analysis of modulated S -nitrosothiols (SNO-proteins) in freshly-harvested organs of animals sacrificed 13 days after irradiation revealed radiation dose- and contrast agent-dependent changes. The major results were as follows: (i) iopamidol alone had significant effects on S -nitrosylation in brain, lung and liver; (ii) relative to the control, exposure to 0.1 Gy without iopamidol resulted in statistically-significant SNO changes in proteins that differ in molecular weight in liver, lung, brain and blood plasma; (iii) iopamidol enhanced the decrease in S -nitrosylation induced by 0.1 Gy in brain; (iv) whereas a decrease in S -nitrosylation occurred at 0.1 Gy for proteins of ~50 kDa in brain and for proteins of ~37 kDa in liver, an increase was detected at 4 Gy in both organs; (v) mass spectrometry analyses of nitrosylated proteins in brain revealed differential modulation of SNO proteins (e.g., sodium/potassium-transporting ATPase subunit beta-1; beta tubulins; ADP-ribosylation factor 5) by low- and high-dose irradiation; and (vi) ingenuity pathway analysis identified major signaling networks to be modulated, in particular the neuronal nitric oxide synthase signaling pathway was differentially modulated by low- and high-dose γ-irradiation.
NASA Technical Reports Server (NTRS)
Shavers, M. R.; Zapp, N.; Barber, R. E.; Wilson, J. W.; Qualls, G.; Toupes, L.; Ramsey, S.; Vinci, V.; Smith, G.; Cucinotta, F. A.
2004-01-01
With 5-7 month long duration missions at 51.6 degrees inclination in Low Earth Orbit, the ionizing radiation levels to which International Space Station (ISS) crewmembers are exposed will be the highest planned occupational exposures in the world. Even with the expectation that regulatory dose limits will not be exceeded during a single tour of duty aboard the ISS, the "as low as reasonably achievable" (ALARA) precept requires that radiological risks be minimized when possible through a dose optimization process. Judicious placement of efficient shielding materials in locations where crewmembers sleep, rest, or work is an important means for implementing ALARA for spaceflight. Polyethylene (CnHn) is a relatively inexpensive, stable, and, with a low atomic number, an effective shielding material that has been certified for use aboard the ISS. Several designs for placement of slabs or walls of polyethylene have been evaluated for radiation exposure reduction in the Crew Quarters (CQ) of the Zvezda (Star) Service Module. Optimization of shield designs relies on accurate characterization of the expected primary and secondary particle environment and modeling of the predicted radiobiological responses of critical organs and tissues. Results of the studies shown herein indicate that 20% or more reduction in equivalent dose to the CQ occupant is achievable. These results suggest that shielding design and risk analysis are necessary measures for reducing long-term radiological risks to ISS inhabitants and for meeting legal ALARA requirements. Verification of shield concepts requires results from specific designs to be compared with onboard dosimetry. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Shavers, M.; Zapp, N.; Barber, R.; Wilson, J.; Qualls, G.; Toupes, L.; Ramsey, S.; Vinci, V.; Smith, G.; Cucinotta, F.
With 5 to 7-month long duration missions at 51.6° inclination in Low Earth Orbit, the ionizing radiation levels to which International Space Station (ISS) crewmembers are exposed will be the highest planned occupational exposures in the world. Even with the expectation that regulatory dose limits will not be exceeded during a single tour of duty aboard the ISS, the "as low as reasonably achievable" (ALARA) precept requires that radiological risks be minimized when possible through an dose optimization process. Judicious placement of efficient shielding materials in locations where crewmembers sleep, rest, or work is an important means for implementing ALARA for spaceflight. Polyethylene (Cn Hn ), is a relatively inexpensive, stable, and, with a low atomic number, an effective shielding material that has been certified for use aboard the ISS. Several designs for placement of slabs or walls of polyethylene have been evaluated for radiation exposure reduction in the Crew Quarters (CQ) of the Zvezda (Star) Service Module. Optimization of shield designs relies on accurate characterization of the expected primary and secondary particle environment and modeling of the predicted radiobiological responses of critical organs and tissues. Results of the studies shown herein indicate that 20% or more reduction in dose equivalent to the CQ occupant is achievable. These results suggest that shielding design and risk analysis are necessary measures for reducing long-term radiological risks to ISS inhabitants and for meeting legal ALARA requirements. Verification of shield concepts requires results from specific designs to be compared with onboard dosimetry.
NASA Astrophysics Data System (ADS)
Shavers, M. R.; Zapp, N.; Barber, R. E.; Wilson, J. W.; Qualls, G.; Toupes, L.; Ramsey, S.; Vinci, V.; Smith, G.; Cucinotta, F. A.
2004-01-01
With 5-7 month long duration missions at 51.6° inclination in Low Earth Orbit, the ionizing radiation levels to which International Space Station (ISS) crewmembers are exposed will be the highest planned occupational exposures in the world. Even with the expectation that regulatory dose limits will not be exceeded during a single tour of duty aboard the ISS, the "as low as reasonably achievable" (ALARA) precept requires that radiological risks be minimized when possible through a dose optimization process. Judicious placement of efficient shielding materials in locations where crewmembers sleep, rest, or work is an important means for implementing ALARA for spaceflight. Polyethylene (C nH n) is a relatively inexpensive, stable, and, with a low atomic number, an effective shielding material that has been certified for use aboard the ISS. Several designs for placement of slabs or walls of polyethylene have been evaluated for radiation exposure reduction in the Crew Quarters (CQ) of the Zvezda (Star) Service Module. Optimization of shield designs relies on accurate characterization of the expected primary and secondary particle environment and modeling of the predicted radiobiological responses of critical organs and tissues. Results of the studies shown herein indicate that 20% or more reduction in equivalent dose to the CQ occupant is achievable. These results suggest that shielding design and risk analysis are necessary measures for reducing long-term radiological risks to ISS inhabitants and for meeting legal ALARA requirements. Verification of shield concepts requires results from specific designs to be compared with onboard dosimetry.
Environmental radiology assessment in Lahad Datu, Sabah
NASA Astrophysics Data System (ADS)
Siti Fharhana, Yusof; Wan Muhamad Saridan, Wan Hassan; Ahmad Termizi, Ramli; Mohd Hilmi, Sahini; Mohammad Syazwan, Mohd Sanusi; Nor Afifah, Basri; Nor Zati Hani, Abu Hanifah
2017-10-01
Monitoring terrestial gamma radiation is crucial to prepare a baseline data for environmental radiological protection. Radiological research was carried out in Lahad Datu, Sabah to obtain the radioactivity status and terrestrial gamma radiation level in the area. We measure the terrestrial gamma radiation dose rates and analyse the radioactivity concentration of primordial radionuclides for radiological risk assessment. We identified that the annual estimation of dose effective for public is below the public dose limit, 1 mSv per year. Public and environment safety and health are remain secure. The obtained data and results can be used as reference for environmental radiology protection.
Patient Dose In Diagnostic Radiology: When & How?
NASA Astrophysics Data System (ADS)
Lassen, Margit; Gorson, Robert O.
1980-08-01
Different situations are discussed in which it is of value to know radiation dose to the patient in diagnostic radiology. Radiation dose to specific organs is determined using the Handbook on Organ Doses published by the Bureau of Radiological Health of the Food and Drug Administration; the method is applied to a specific case. In this example dose to an embryo is calculated in examinations involving both fluoroscopy and radiography. In another example dose is determined to a fetus in late pregnancy using tissue air ratios. Patient inquiries about radiation dose are discussed, and some answers are suggested. The reliability of dose calculations is examined.
Faggioni, Lorenzo; Paolicchi, Fabio; Bastiani, Luca; Guido, Davide; Caramella, Davide
2017-01-01
To evaluate the awareness of radiation protection issues and the knowledge of dose levels of imaging procedures among medical students, radiology residents, and radiography students at an academic hospital. A total of 159 young doctors and students (including 60 radiology residents, 56 medical students, and 43 radiography students) were issued a questionnaire consisting of 16 multiple choice questions divided into three separated sections (i.e., demographic data, awareness about radiation protection issues, and knowledge about radiation dose levels of common radiological examinations). Medical students claimed to have at least a good knowledge of radiation protection issues more frequently than radiology residents and radiography students (94.4% vs 55% and 35.7%, respectively; P<0.05), with no cases of perceived excellent knowledge among radiography students. However, the actual knowledge of essential radiation protection topics such as regulations, patient and tissue susceptibility to radiation damage, professional radiation risk and dose optimisation, as well as of radiation doses delivered by common radiological procedures was significantly worse among medical students than radiology residents and radiography students (P<0.05). Those latter significantly outperformed radiology residents as to knowledge of radiation protection issues (P<0.01). Overall, less than 50% of survey respondents correctly answered all questions of the survey. Radiology residents, radiography students and medical students have a limited awareness about radiation protection, with a specific gap of knowledge concerning real radiation doses of daily radiological examinations. Both undergraduate and postgraduate teaching needs to be effectively implemented with radiation safety courses. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Abrisham, Seyed Mohammad J.; Bouzarjomehri, Fathollah; Nafisi-Moghadam, Reza; Sobhan, Mohammad R.; Gadimi, Mahdie; Omidvar, Fereshte
2017-01-01
Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and precision of the system was confirmed according to the acceptance testing. The same procedure was used for 18 patients referred for lumbar spine digital radiology (overall 36 images). Results: Although radiation fields in the EOS were almost twice of that in digital radiology, and the average peak tube voltage (kVp), current supply to the tube (mA), and the average size and age of the patients referred for EOS imaging were greater than digital radiology, however, the average DAP in EOS was 1/5 of that in digital radiology system. Also, the average dose in the EOS was about 1/20 of that in digital radiology. Conclusion: The patient dose in EOS imaging system was lower in comparison with digital radiology (1/20). PMID:28656161
Abrisham, Seyed Mohammad J; Bouzarjomehri, Fathollah; Nafisi-Moghadam, Reza; Sobhan, Mohammad R; Gadimi, Mahdie; Omidvar, Fereshte
2017-05-01
This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and precision of the system was confirmed according to the acceptance testing. The same procedure was used for 18 patients referred for lumbar spine digital radiology (overall 36 images). Although radiation fields in the EOS were almost twice of that in digital radiology, and the average peak tube voltage (kV p ), current supply to the tube (mA), and the average size and age of the patients referred for EOS imaging were greater than digital radiology, however, the average DAP in EOS was 1/5 of that in digital radiology system. Also, the average dose in the EOS was about 1/20 of that in digital radiology. The patient dose in EOS imaging system was lower in comparison with digital radiology (1/20).
NASA Astrophysics Data System (ADS)
Sato, Tatsuhiko; Satoh, Daiki; Endo, Akira; Shigyo, Nobuhiro; Watanabe, Fusao; Sakurai, Hiroki; Arai, Yoichi
2011-05-01
A dose and spectrum monitoring system applicable to neutrons, photons and muons over wide ranges of energy, designated as DARWIN, has been developed for radiological protection in high-energy accelerator facilities. DARWIN consists of a phoswitch-type scintillation detector, a data-acquisition (DAQ) module for digital waveform analysis, and a personal computer equipped with a graphical-user-interface (GUI) program for controlling the system. The system was recently upgraded by introducing an original DAQ module based on a field programmable gate array, FPGA, and also by adding a function for estimating neutron and photon spectra based on an unfolding technique without requiring any specific scientific background of the user. The performance of the upgraded DARWIN was examined in various radiation fields, including an operational field in J-PARC. The experiments revealed that the dose rates and spectra measured by the upgraded DARWIN are quite reasonable, even in radiation fields with peak structures in terms of both spectrum and time variation. These results clearly demonstrate the usefulness of DARWIN for improving radiation safety in high-energy accelerator facilities.
Yamamoto, Hideo; Yoneda, Tarou; Satou, Shuji; Ishikawa, Toru; Hara, Misako
2009-12-20
By input of the actual dose of a drug given into a radiology information system, the system converting with an accounting system into a cost of the drug from the actual dose in the electronic medical record was built. In the drug master, the first unit was set as the cost of the drug, and we set the second unit as the actual dose. The second unit in the radiology information system was received by the accounting system through electronic medical record. In the accounting system, the actual dose was changed into the cost of the drug using the dose of conversion to the first unit. The actual dose was recorded on a radiology information system and electronic medical record. The actual dose was indicated on the accounting system, and the cost for the drug was calculated. About the actual dose of drug, cooperation of the information in a radiology information system and electronic medical record were completed. It was possible to decide the volume of drug from the correct dose of drug at the previous inspection. If it is necessary for the patient to have another treatment of medicine, it is important to know the actual dose of drug given. Moreover, authenticity of electronic medical record based on a statute has also improved.
Radon Exposure and the Definition of Low Doses-The Problem of Spatial Dose Distribution.
Madas, Balázs G
2016-07-01
Investigating the health effects of low doses of ionizing radiation is considered to be one of the most important fields in radiological protection research. Although the definition of low dose given by a dose range seems to be clear, it leaves some open questions. For example, the time frame and the target volume in which absorbed dose is measured have to be defined. While dose rate is considered in the current system of radiological protection, the same cancer risk is associated with all exposures, resulting in a given amount of energy absorbed by a single target cell or distributed among all the target cells of a given organ. However, the biological effects and so the health consequences of these extreme exposure scenarios are unlikely to be the same. Due to the heterogeneous deposition of radon progeny within the lungs, heterogeneous radiation exposure becomes a practical issue in radiological protection. While the macroscopic dose is still within the low dose range, local tissue doses on the order of Grays can be reached in the most exposed parts of the bronchial airways. It can be concluded that progress in low dose research needs not only low dose but also high dose experiments where small parts of a biological sample receive doses on the order of Grays, while the average dose over the whole sample remains low. A narrow interpretation of low dose research might exclude investigations with high relevance to radiological protection. Therefore, studies important to radiological protection should be performed in the frame of low dose research even if the applied doses do not fit in the dose range used for the definition of low doses.
Ghetti, C; Ortenzia, O; Palleri, F; Sireus, M
2017-06-01
Dose optimization in radiological examinations is a mandatory issue: in this study local Diagnostic Reference Levels (lDRLs) for Clinical Mammography (MG), Computed Tomography (CT) and Interventional Cardiac Procedures (ICP) performed in our Radiology Department were established. Using a dose tracking software, we have collected Average Glandular Dose (AGD) for two clinical mammographic units; CTDIvol, Size-Specific Dose Estimate (SSDE), Dose Length Product (DLP) and total DLP (DLPtot) for five CT scanners; Fluoro Time, Fluoro Dose Area Product (DAP) and total DAP (DAPtot) for two angiographic systems. Data have been compared with Italian Regulation and with the recent literature. The 75th percentiles of the different dosimetric indices have been calculated. Automated methods of radiation dose data collection allow a fast and detailed analysis of a great amount of data and an easy determination of lDRLs for different radiological procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Dose Monitoring in Radiology Departments: Status Quo and Future Perspectives.
Boos, J; Meineke, A; Bethge, O T; Antoch, G; Kröpil, P
2016-05-01
The number of computed tomography examinations has continuously increased over the last decades and accounts for a major part of the collective radiation dose from medical investigations. For purposes of quality assurance in modern radiology a systematic monitoring and analysis of dose related data from radiological examinations is mandatory. Various ways of collecting dose data are available today, for example the Digital Imaging and Communication in Medicine - Structured Report (DICOM-SR), optical character recognition and DICOM-modality performed procedure steps (MPPS). The DICOM-SR is part of the DICOM-standard and provides the DICOM-Radiation Dose Structured Report, which is an easily applicable and comprehensive solution to collect radiation dose parameters. This standard simplifies the process of data collection and enables comprehensive dose monitoring. Various commercial dose monitoring software devices with varying characteristics are available today. In this article, we discuss legal obligations, various ways to monitor dose data, current dose monitoring software solutions and future perspectives in regard to the EU Council Directive 2013/59/EURATOM. • Automated, systematic dose monitoring is an important element in quality assurance of radiology departments. • DICOM-RDSR-capable CT scanners facilitate the monitoring of dose data. • A variety of commercial and non-commercial dose monitoring software tools are available today. • Successful dose monitoring requires comprehensive infrastructure for monitoring, analysing and optimizing radiation exposure. Citation Format: • Boos J, Meineke A, Bethge OT et al. Dose Monitoring in Radiology Departments: Status Quo and Future Perspectives. Fortschr Röntgenstr 2016; 188: 443 - 450. © Georg Thieme Verlag KG Stuttgart · New York.
Mori, Hiroshige
2015-06-01
The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses' annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units' pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses.
Kraus, Terry; Foster, Kevin
2014-08-01
The radiological assessment of the nuclear fallout (i.e., fission and neutron-activation radionuclides) from a nuclear detonation is complicated by the large number of fallout radionuclides. This paper provides the initial isotopic source term inventory of the fallout from a uranium-fueled nuclear detonation and identifies the significant and insignificant radiological dose producing radionuclides over 11 dose integration time periods (time phases) of interest. A primary goal of this work is to produce a set of consistent, time phase-dependent lists of the top dose-producing radionuclides that can be used to prepare radiological assessment calculations and data products (e.g., maps of areas that exceed protective action guidelines) in support of public and worker protection decisions. The ranked lists of top dose-producing radionuclides enable assessors to perform atmospheric dispersion modeling and radiological dose assessment modeling more quickly by using relatively short lists of radionuclides without significantly compromising the accuracy of the modeling and the dose projections. This paper also provides a superset-list of the top dose-producing fallout radionuclides from a uranium-fueled nuclear detonation that can be used to perform radiological assessments over any desired time phase. Furthermore, this paper provides information that may be useful to monitoring and sampling and laboratory analysis personnel to help understand which radionuclides are of primary concern. Finally, this paper may be useful to public protection decision makers because it shows the importance of quickly initiating public protection actions to minimize the radiological dose from fallout.
A web based Foundations of Radiological Physics for diagnostic radiology residents.
Blackmon, Kevin N; Huda, Walter; Lewis, Madelene C; Tipnis, Sameer; Mah, Eugene; Frey, Donald G
2013-03-01
RATIONALE AND OBJECTS: We describe a new web-based physics course for radiology residents preparing for the Exam of the Future (EOF). A course was developed with a total of 12 web-based modules. Six modules were focused on "imaging" and six on "radiation." A module was subdivided into nine short "nuggets." Traditional lectures were replaced by modules using prerecorded lectures (Tegrity) to a secure website (WebCT). Each module was accompanied by three quizzes, each consisting of ten questions designed to reinforce covered materials. All online modules were accompanied by a noon conference that employed an Audience Response System (Turning Point). Seventeen first-year residents over 2 consecutive years beginning in July 2010 took this new course, and participated in an anonymous online follow-up survey (Survey Monkey). The recorded 12 modules had an overall average duration of 72 ± 19 minutes. Ten of 17 residents expressed a preference of 15 minutes for nugget duration. Highest personal assessment scores of each resident's understanding were obtained in human radiation risks and radiation protection. Residents considered supplemental noon conferences to be important for learning radiological physics. Satisfaction level was largely positive, with five residents highly satisfied, nine residents somewhat satisfied, two residents neutral, and only one resident somewhat dissatisfied. Our Foundations of Radiological Physics course was well received and served as the springboard for mastering x-ray-based imaging modalities of radiography, mammography, fluoroscopy, interventional radiology, and computed tomography. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
Development and Impact Evaluation of an E-Learning Radiation Oncology Module
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alfieri, Joanne, E-mail: Joanne.alfieri@mail.mcgill.ca; Portelance, Lorraine; Souhami, Luis
Purpose: Radiation oncologists are faced with the challenge of irradiating tumors to a curative dose while limiting toxicity to healthy surrounding tissues. This can be achieved only with superior knowledge of radiologic anatomy and treatment planning. Educational resources designed to meet these specific needs are lacking. A web-based interactive module designed to improve residents' knowledge and application of key anatomy concepts pertinent to radiotherapy treatment planning was developed, and its effectiveness was assessed. Methods and Materials: The module, based on gynecologic malignancies, was developed in collaboration with a multidisciplinary team of subject matter experts. Subsequently, a multi-centre randomized controlled studymore » was conducted to test the module's effectiveness. Thirty-six radiation oncology residents participated in the study; 1920 were granted access to the module (intervention group), and 17 in the control group relied on traditional methods to acquire their knowledge. Pretests and posttests were administered to all participants. Statistical analysis was carried out using paired t test, analysis of variance, and post hoc tests. Results: The randomized control study revealed that the intervention group's pretest and posttest mean scores were 35% and 52%, respectively, and those of the control group were 37% and 42%, respectively. The mean improvement in test scores was 17% (p < 0.05) for the intervention group and 5% (p = not significant) for the control group. Retrospective pretest and posttest surveys showed a statistically significant change on all measured module objectives. Conclusions: The use of an interactive e-learning teaching module for radiation oncology is an effective method to improve the radiologic anatomy knowledge and treatment planning skills of radiation oncology residents.« less
Endo, A; Katoh, T; Kobayashi, I; Joshi, R; Sur, J; Okano, T
2012-01-01
Objective The aim of this study was to assess the characteristics of an optically stimulated luminescence dosemeter (OSLD) for use in diagnostic radiology and to apply the OSLD in measuring the organ doses by panoramic radiography. Methods The dose linearity, energy dependency and angular dependency of aluminium oxide-based OSLDs were examined using an X-ray generator to simulate various exposure settings in diagnostic radiology. The organ doses were then measured by inserting the dosemeters into an anthropomorphic phantom while using three panoramic machines. Results The dosemeters demonstrated consistent dose linearity (coefficient of variation<1.5%) and no significant energy dependency (coefficient of variation<1.5%) under the applied exposure conditions. They also exhibited negligible angular dependency (≤10%). The organ doses of the X-ray as a result of panoramic imaging by three machines were calculated using the dosemeters. Conclusion OSLDs can be utilized to measure the organ doses in diagnostic radiology. The availability of these dosemeters in strip form proves to be reliably advantageous. PMID:22116136
NASA Astrophysics Data System (ADS)
Sayre, George Anthony
The purpose of this dissertation was to develop the C ++ program Emergency Dose to calculate transport of radionuclides through indoor spaces using intermediate fidelity physics that provides improved spatial heterogeneity over well-mixed models such as MELCORRTM and much lower computation times than CFD codes such as FLUENTRTM . Modified potential flow theory, which is an original formulation of potential flow theory with additions of turbulent jet and natural convection approximations, calculates spatially heterogeneous velocity fields that well-mixed models cannot predict. Other original contributions of MPFT are: (1) generation of high fidelity boundary conditions relative to well-mixed-CFD coupling methods (conflation), (2) broadening of potential flow applications to arbitrary indoor spaces previously restricted to specific applications such as exhaust hood studies, and (3) great reduction of computation time relative to CFD codes without total loss of heterogeneity. Additionally, the Lagrangian transport module, which is discussed in Sections 1.3 and 2.4, showcases an ensemble-based formulation thought to be original to interior studies. Velocity and concentration transport benchmarks against analogous formulations in COMSOLRTM produced favorable results with discrepancies resulting from the tetrahedral meshing used in COMSOLRTM outperforming the Cartesian method used by Emergency Dose. A performance comparison of the concentration transport modules against MELCORRTM showed that Emergency Dose held advantages over the well-mixed model especially in scenarios with many interior partitions and varied source positions. A performance comparison of velocity module against FLUENTRTM showed that viscous drag provided the largest error between Emergency Dose and CFD velocity calculations, but that Emergency Dose's turbulent jets well approximated the corresponding CFD jets. Overall, Emergency Dose was found to provide a viable intermediate solution method for concentration transport with relatively low computation times.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-30
... Radiological Protection; Recommendations on the Annual Dose Limit to the Lens of the Eye AGENCY: Nuclear... Protection (ICRP) recommendations for the limitation of annual dose to the lens of the eye. This significant... might be lower than previously considered. For the lens of the eye, the threshold in absorbed dose for...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meghzifene, A; Berris, T
Purpose: To provide the professional medical physicists with adequate competencies and skills in order to help them get prepared to support Nuclear or Radiological Emergency (NRE) situations. Methods: Although clinical medical physicists working have in-depth knowledge in radiation dosimetry, including dose reconstruction and dose measurements, they are usually not involved in NRE situations. However, in a few instances where medical physicists were involved in NREs, it appeared that many lacked specific knowledge and skills that are required in such situations. This lack of specific knowledge and skills is probably due to the fact that most current medical physics curricula domore » not include a specific module on this topic. As a response to this finding, the IAEA decided to initiate a project to develop a specific training package to help prepare medical physicists to support NRE situations. The training package was developed with the kind support of the Government of Japan and in collaboration with Fukushima Medical University (FMU) and the National Institute of Radiological Sciences (NIRS). Results: The first International Workshop to test the training package was held in Fukushima, Japan in June 2015. It consisted of lectures, demonstrations, simulation, role play, and practical sessions followed by discussions. The training was delivered through 14 modules which were prepared with the support of 12 lecturers. A knowledge assessment test was done before the workshop, followed by the same test done at the end of the Workshop, to assess the knowledge acquired during the training. Conclusion: The Workshop was successfully implemented. The overall rating of the workshop by the participants was excellent and all participants reported that they acquired a good understanding of the main issues that are relevant to medical physics support in case of NRE situations. They are expected to disseminate the knowledge to other medical physicists in their countries.« less
Mehta, Shaesta; Kalyani, Nikhil; Chaudhari, Suresh; Dharia, Tejas; Shetty, Nitin; Chopra, Supriya; Goel, Mahesh; Kulkarni, Suyash; Shrivastava, Shyam Kishore
2017-01-01
Background We present results of patients diagnosed with unresectable hilar cholangiocarcinomas treated with high dose radiotherapy and concurrent chemotherapy. Methods From Aug 2005 to Dec 2012, 68 consecutive patients were treated. Fifty patients (group 1) presenting to us with obstructive jaundice were planned for endobiliary brachytherapy (EBBT 14 Gy) followed external beam radiotherapy (EBRT 45 Gy). Twenty-two patients (group 2) who had previously undergone biliary drainage underwent EBRT (57 Gy). All patients received injection Gemcitabine 300 mg/m2/weekly along with EBRT. Results Twenty-nine patients in group 1 and 22 patients in group 2 completed the treatment. Twenty-six (55%) patients achieved complete radiological response, 16 (64%) belonging to group 1 and 8 (44%) of group 2 (P=0.05). The median overall survival (MOS) was 17.5 and 16 months for group 1 and 2 respectively (P=0.07). The 1- and 2-year survival was 63%, and 18% for group I and 61% and 22% for group II respectively. The MOS was 5 months and 1 year survival was 14% for patients receiving EBBT only. MOS was significantly better after complete response (P=0.001). Conclusions Intensity modulated radiotherapy (IMRT) modulated high dose radiotherapy used either alone or with brachytherapy demonstrates potential to prolonged overall survival in unresectable hilar cholangiocarcinomas. PMID:28280622
NASA Astrophysics Data System (ADS)
McCurdy, B. M. C.
2013-06-01
An overview is provided of the use of amorphous silicon electronic portal imaging devices (EPIDs) for dosimetric purposes in radiation therapy, focusing on 3D patient dose estimation. EPIDs were originally developed to provide on-treatment radiological imaging to assist with patient setup, but there has also been a natural interest in using them as dosimeters since they use the megavoltage therapy beam to form images. The current generation of clinically available EPID technology, amorphous-silicon (a-Si) flat panel imagers, possess many characteristics that make them much better suited to dosimetric applications than earlier EPID technologies. Features such as linearity with dose/dose rate, high spatial resolution, realtime capability, minimal optical glare, and digital operation combine with the convenience of a compact, retractable detector system directly mounted on the linear accelerator to provide a system that is well-suited to dosimetric applications. This review will discuss clinically available a-Si EPID systems, highlighting dosimetric characteristics and remaining limitations. Methods for using EPIDs in dosimetry applications will be discussed. Dosimetric applications using a-Si EPIDs to estimate three-dimensional dose in the patient during treatment will be overviewed. Clinics throughout the world are implementing increasingly complex treatments such as dynamic intensity modulated radiation therapy and volumetric modulated arc therapy, as well as specialized treatment techniques using large doses per fraction and short treatment courses (ie. hypofractionation and stereotactic radiosurgery). These factors drive the continued strong interest in using EPIDs as dosimeters for patient treatment verification.
Miller, Donald L.; Kwon, Deukwoo; Bonavia, Grant H.
2009-01-01
Purpose: To propose initial values for patient reference levels for fluoroscopically guided procedures in the United States. Materials and Methods: This secondary analysis of data from the Radiation Doses in Interventional Radiology Procedures (RAD-IR) study was conducted under a protocol approved by the institutional review board and was HIPAA compliant. Dose distributions (percentiles) were calculated for each type of procedure in the RAD-IR study where there were data from at least 30 cases. Confidence intervals for the dose distributions were determined by using bootstrap resampling. Weight banding and size correction methods for normalizing dose to patient body habitus were tested. Results: The different methods for normalizing patient radiation dose according to patient weight gave results that were not significantly different (P > .05). The 75th percentile patient radiation doses normalized with weight banding were not significantly different from those that were uncorrected for body habitus. Proposed initial reference levels for various interventional procedures are provided for reference air kerma, kerma-area product, fluoroscopy time, and number of images. Conclusion: Sufficient data exist to permit an initial proposal of values for reference levels for interventional radiologic procedures in the United States. For ease of use, reference levels without correction for body habitus are recommended. A national registry of radiation-dose data for interventional radiologic procedures is a necessary next step to refine these reference levels. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533090354/-/DC1 PMID:19789226
THE RABIT: A RAPID AUTOMATED BIODOSIMETRY TOOL FOR RADIOLOGICAL TRIAGE
Garty, Guy; Chen, Youhua; Salerno, Alessio; Turner, Helen; Zhang, Jian; Lyulko, Oleksandra; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Yao, Y. Lawrence; Amundson, Sally A.; Brenner, David J.
2010-01-01
In response to the recognized need for high throughput biodosimetry methods for use after large scale radiological events, a logical approach is complete automation of standard biodosimetric assays that are currently performed manually. We describe progress to date on the RABIT (Rapid Automated BIodosimetry Tool), designed to score micronuclei or γ-H2AX fluorescence in lymphocytes derived from a single drop of blood from a fingerstick. The RABIT system is designed to be completely automated, from the input of the capillary blood sample into the machine, to the output of a dose estimate. Improvements in throughput are achieved through use of a single drop of blood, optimization of the biological protocols for in-situ analysis in multi-well plates, implementation of robotic plate and liquid handling, and new developments in high-speed imaging. Automating well-established bioassays represents a promising approach to high-throughput radiation biodosimetry, both because high throughputs can be achieved, but also because the time to deployment is potentially much shorter than for a new biological assay. Here we describe the development of each of the individual modules of the RABIT system, and show preliminary data from key modules. Ongoing is system integration, followed by calibration and validation. PMID:20065685
A presentation system for just-in-time learning in radiology.
Kahn, Charles E; Santos, Amadeu; Thao, Cheng; Rock, Jayson J; Nagy, Paul G; Ehlers, Kevin C
2007-03-01
There is growing interest in bringing medical educational materials to the point of care. We sought to develop a system for just-in-time learning in radiology. A database of 34 learning modules was derived from previously published journal articles. Learning objectives were specified for each module, and multiple-choice test items were created. A web-based system-called TEMPO-was developed to allow radiologists to select and view the learning modules. Web services were used to exchange clinical context information between TEMPO and the simulated radiology work station. Preliminary evaluation was conducted using the System Usability Scale (SUS) questionnaire. TEMPO identified learning modules that were relevant to the age, sex, imaging modality, and body part or organ system of the patient being viewed by the radiologist on the simulated clinical work station. Users expressed a high degree of satisfaction with the system's design and user interface. TEMPO enables just-in-time learning in radiology, and can be extended to create a fully functional learning management system for point-of-care learning in radiology.
Radiological Source Terms for Tank Farms Safety Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
COWLEY, W.L.
2000-06-27
This document provides Unit Liter Dose factors, atmospheric dispersion coefficients, breathing rates and instructions for using and customizing these factors for use in calculating radiological doses for accident analyses in the Hanford Tank Farms.
Radiological protection in computed tomography and cone beam computed tomography.
Rehani, M M
2015-06-01
The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nazififard, Mohammad, E-mail: nazifi@kashanu.ac.ir; Mahmoudieh, Afshin; Suh, Kune Y.
Silicon PIN photodiode has recently found broad and exciting applications in the ionizing radiation dosimetry. In this study a compact and novel dosimetry system using a commercially available PIN photodiode (BPW34) has been experimentally tested for diagnostic radiology. The system was evaluated with clinical beams routinely used for diagnostic radiology and calibrated using a secondary reference standard. Measured dose with PIN photodiode (Air Kerma) varied from 10 to 430 μGy for tube voltages from 40 to 100 kVp and tube current from 0.4 to 40 mAs. The minimum detectable organ dose was estimated to be 10 μGy with 20% uncertainty.more » Results showed a linear correlation between the PIN photodiode readout and dose measured with standard dosimeters spanning doses received. The present dosimetry system having advantages of suitable sensitivity with immediate readout of dose values, low cost, and portability could be used as an alternative to passive dosimetry system such as thermoluminescent dosimeter for dose measurements in diagnostic radiology.« less
Howlett, David; Vincent, Tim; Watson, Gillian; Owens, Emma; Webb, Richard; Gainsborough, Nicola; Fairclough, Jil; Taylor, Nick; Miles, Ken; Cohen, Jon; Vincent, Richard
2011-06-01
To review the initial experience of blending a variety of online educational techniques with traditional face to face or contact-based teaching methods to deliver final year undergraduate radiology content at a UK Medical School. The Brighton and Sussex Medical School opened in 2003 and offers a 5-year undergraduate programme, with the final 5 spent in several regional centres. Year 5 involves several core clinical specialities with onsite radiology teaching provided at regional centres in the form of small-group tutorials, imaging seminars and also a one-day course. An online educational module was introduced in 2007 to facilitate equitable delivery of the year 5 curriculum between the regional centres and to support students on placement. This module had a strong radiological emphasis, with a combination of imaging integrated into clinical cases to reflect everyday practice and also dedicated radiology cases. For the second cohort of year 5 students in 2008 two additional online media-rich initiatives were introduced, to complement the online module, comprising imaging tutorials and an online case discussion room. In the first year for the 2007/2008 cohort, 490 cases were written, edited and delivered via the Medical School managed learning environment as part of the online module. 253 cases contained a form of image media, of which 195 cases had a radiological component with a total of 325 radiology images. Important aspects of radiology practice (e.g. consent, patient safety, contrast toxicity, ionising radiation) were also covered. There were 274,000 student hits on cases the first year, with students completing a mean of 169 cases each. High levels of student satisfaction were recorded in relation to the online module and also additional online radiology teaching initiatives. Online educational techniques can be effectively blended with other forms of teaching to allow successful undergraduate delivery of radiology. Efficient IT links and good image quality are essential ingredients for successful student/clinician engagement. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Overview of ICRP Committee 3: protection in medicine.
Vañó, E; Miller, D L; Rehani, M M
2016-06-01
Committee 3 of the International Commission on Radiological Protection (ICRP) develops recommendations and guidance for protection of patients, staff, and the public against radiation exposure when ionising radiation is used for medical diagnosis, therapy, or biomedical research. This paper presents a summary of the work that Committee 3 has accomplished over the past few years, and also describes its current work. The most recent reports published by the Commission that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (Publication 129), 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (Publication 128, in cooperation with Committee 2), 'Radiological protection in ion beam radiotherapy' (Publication 127), 'Radiological protection in paediatric diagnostic and interventional radiology' (Publication 121), 'Radiological protection in cardiology' (Publication 120), and 'Radiological protection in fluoroscopically guided procedures outside the imaging department' (Publication 117). A new report on diagnostic reference levels in medical imaging will provide specific advice for interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and hybrid (multi-modality) imaging procedures, and is expected to be published in 2016. Committee 3 is also working on guidance for occupational radiological protection in brachytherapy, and on guidance on occupational protection issues in interventional procedures, paying particular attention to the 2011 Commission's recommendations on the occupational dose limit for the lens of the eye (Publication 118). Other reports in preparation deal with justification, radiological protection in therapy with radiopharmaceuticals, radiological protection in medicine as related to individual radiosusceptibility, appropriate use of effective dose (in cooperation with other Committees), and guidance for healthcare practitioners on radiological and patient protection. Committee 3 has also suggested specific priorities for research on radiological protection in medicine to the Commission. © The International Society for Prosthetics and Orthotics.
Methods for Probabilistic Radiological Dose Assessment at a High-Level Radioactive Waste Repository.
NASA Astrophysics Data System (ADS)
Maheras, Steven James
Methods were developed to assess and evaluate the uncertainty in offsite and onsite radiological dose at a high-level radioactive waste repository to show reasonable assurance that compliance with applicable regulatory requirements will be achieved. Uncertainty in offsite dose was assessed by employing a stochastic precode in conjunction with Monte Carlo simulation using an offsite radiological dose assessment code. Uncertainty in onsite dose was assessed by employing a discrete-event simulation model of repository operations in conjunction with an occupational radiological dose assessment model. Complementary cumulative distribution functions of offsite and onsite dose were used to illustrate reasonable assurance. Offsite dose analyses were performed for iodine -129, cesium-137, strontium-90, and plutonium-239. Complementary cumulative distribution functions of offsite dose were constructed; offsite dose was lognormally distributed with a two order of magnitude range. However, plutonium-239 results were not lognormally distributed and exhibited less than one order of magnitude range. Onsite dose analyses were performed for the preliminary inspection, receiving and handling, and the underground areas of the repository. Complementary cumulative distribution functions of onsite dose were constructed and exhibited less than one order of magnitude range. A preliminary sensitivity analysis of the receiving and handling areas was conducted using a regression metamodel. Sensitivity coefficients and partial correlation coefficients were used as measures of sensitivity. Model output was most sensitive to parameters related to cask handling operations. Model output showed little sensitivity to parameters related to cask inspections.
Mathematics for the Workplace. Applications from Radiological Technology. A Teacher's Guide.
ERIC Educational Resources Information Center
Wallace, Johnny M.; Nichols, Gay
This module presents a real-world context in which mathematics skills are used as part of a daily routine. The context is the radiological technology field, and the module aims to help students use ratios and exponents as part of real-life problem solving. Materials in the module, most of which are designed for the teacher to duplicate and…
Walsh, C; Gallagher, A; Dowling, A; Guiney, M; Ryan, J M; McEniff, N; O'Reilly, G
2015-01-01
Objective: In 2011, the International Commission on Radiological Protection (ICRP) recommended a substantial reduction in the equivalent dose limit for the lens of the eye, in line with a reduced threshold of absorbed dose for radiation-induced cataracts. This is of particular relevance in interventional radiology (IR) where it is well established that staff doses can be significant, however, there is a lack of data on IR eye doses in terms of Hp(3). Hp(3) is the personal dose equivalent at a depth of 3 mm in soft tissue and is used for measuring lens dose. We aimed to obtain a reliable estimate of eye dose to IR operators. Methods: Lens doses were measured for four interventional radiologists over a 3-month period using dosemeters specifically designed to measure Hp(3). Results: Based on their typical workloads, two of the four interventional radiologists would exceed the new ICRP dose limit with annual estimated doses of 31 and 45 mSv to their left eye. These results are for an “unprotected” eye, and for IR staff who routinely wear lead glasses, the dose beneath the glasses is likely to be significantly lower. Staff eye dose normalized to patient kerma–area product and eye dose per procedure have been included in the analysis. Conclusion: Eye doses to IR operators have been established using a dedicated Hp(3) dosemeter. Estimated annual doses have the potential to exceed the new ICRP limit. Advances in knowledge: We have estimated lens dose to interventional radiologists in terms of Hp(3) for the first time in an Irish hospital setting. PMID:25761211
Lee, Choonsik; Kim, Kwang Pyo; Bolch, Wesley E; Moroz, Brian E; Folio, Les
2015-12-01
We developed computational methods and tools to assess organ doses for pediatric and adult patients undergoing computed tomography (CT) examinations. We used the International Commission on Radiological Protection (ICRP) reference pediatric and adult phantoms combined with the Monte Carlo simulation of a reference CT scanner to establish comprehensive organ dose coefficients (DC), organ absorbed dose per unit volumetric CT Dose Index (CTDIvol) (mGy/mGy). We also developed methods to estimate organ doses with tube current modulation techniques and size specific dose estimates. A graphical user interface was designed to obtain user input of patient- and scan-specific parameters, and to calculate and display organ doses. A batch calculation routine was also integrated into the program to automatically calculate organ doses for a large number of patients. We entitled the computer program, National Cancer Institute dosimetry system for CT(NCICT). We compared our dose coefficients with those from CT-Expo, and evaluated the performance of our program using CT patient data. Our pediatric DCs show good agreements of organ dose estimation with those from CT-Expo except for thyroid. Our results support that the adult phantom in CT-Expo seems to represent a pediatric individual between 10 and 15 years rather than an adult. The comparison of CTDIvol values between NCICT and dose pages from 10 selected CT scans shows good agreements less than 12% except for two cases (up to 20%). The organ dose comparison between mean and modulated mAs shows that mean mAs-based calculation significantly overestimates dose (up to 2.4-fold) to the organs in close proximity to lungs in chest and chest-abdomen-pelvis scans. Our program provides more realistic anatomy based on the ICRP reference phantoms, higher age resolution, the most up-to-date bone marrow dosimetry, and several convenient features compared to previous tools. The NCICT will be available for research purpose in the near future.
ESR dosimetry for atomic bomb survivors and radiologic technologists
NASA Astrophysics Data System (ADS)
Tatsumi-Miyajima, Junko
1987-06-01
An individual absorbed dose for atomic bomb (A-bomb) survivors and radiologic technologists has been estimated using a new personal dosimetry. This dosimetry is based on the electron spin resonance (ESR) spectroscopy of the CO 33- radicals, which are produced in their teeth by radiation. Measurements were carried out to study the characteristics of the dosimetry; the ESR signals of the CO 33- radicals were stable and increased linearly with the radiation dose. In the evaluation of the absorbed dose, the ESR signals were considered to be a function of photon energy. The absorbed doses in ten cases of A-bomb victims and eight cases of radiologic technologists were determined. For A-bomb survivors, the adsorbed doses, which were estimated using the ESR dosimetry, were consistent with the ones obtained using the calculations of the tissue dose in air of A-bomb, and also with the ones obtained using the chromosome measurements. For radiologic technologists, the absorbed doses, which were estimated using the ESR dosimetry, agreed with the ones calculated using the information on the occupational history and conditions. The advantages of this method are that the absorbed dose can be directly estimated by measuring the ESR signals obtained from the teeth of persons, who are exposed to radiation. Therefore, the ESR dosimetry is useful to estimate the accidental exposure and the long term cumulative dose.
Cumulative radiation dose caused by radiologic studies in critically ill trauma patients.
Kim, Patrick K; Gracias, Vicente H; Maidment, Andrew D A; O'Shea, Michael; Reilly, Patrick M; Schwab, C William
2004-09-01
Critically ill trauma patients undergo many radiologic studies, but the cumulative radiation dose is unknown. The purpose of this study was to estimate the cumulative effective dose (CED) of radiation resulting from radiologic studies in critically ill trauma patients. The study group was composed of trauma patients at an urban Level I trauma center with surgical intensive care unit length of stay (LOS) greater than 30 days. The radiology records were reviewed. A typical effective dose per study for each type of plain film radiograph, computed tomographic scan, fluoroscopic study, and nuclear medicine study was used to calculate CED. Forty-six patients met criteria. The mean surgical intensive care unit and hospital LOS were 42.7 +/- 14.0 and 59.5 +/- 28.5 days, respectively. The mean Injury Severity Score was 32.2 +/- 15.0. The mean number of studies per patient was 70.1 +/- 29.0 plain film radiographs, 7.8 +/- 4.1 computed tomographic scans, 2.5 +/- 2.6 fluoroscopic studies, and 0.065 +/- 0.33 nuclear medicine study. The mean CED was 106 +/- 59 mSv per patient (range, 11-289 mSv; median, 104 mSv). Among age, mechanism, Injury Severity Score, and LOS, there was no statistically significant predictor of high CED. The mean CED in the study group was 30 times higher than the average yearly radiation dose from all sources for individuals in the United States. The theoretical additional morbidity attributable to radiologic studies was 0.78%. From a radiobiologic perspective, risk-to-benefit ratios of radiologic studies are favorable, given the importance of medical information obtained. Current practice patterns regarding use of radiologic studies appear to be acceptable.
Vassileva, J; Simeonov, F; Avramova-Cholakova, S
2015-07-01
According to the Bulgarian regulation for radiation protection at medical exposure, the National Centre of Radiobiology and Radiation Protection (NCRRP) is responsible for performing national dose surveys in diagnostic and interventional radiology and nuclear medicine and for establishing of national diagnostic reference levels (DRLs). The next national dose survey is under preparation to be performed in the period of 2015-16, with the aim to cover conventional radiography, mammography, conventional fluoroscopy, interventional and fluoroscopy guided procedures and CT. It will be performed electronically using centralised on-line data collection platform established by the NCRRP. The aim is to increase the response rate and to improve the accuracy by reducing human errors. The concept of the on-line dose data collection platform is presented. Radiological facilities are provided with a tool to determine local typical patient doses, and the NCRRP to establish national DRLs. Future work will include automatic retrieval of dose data from hospital picture archival and communicating system. The on-line data collection platform is expected to facilitate the process of dose audit and optimisation of radiological procedures in Bulgarian hospitals. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Brandan, M.-E.; Ruiz-Trejo, C.; Caspani, C. E. M.; Fleitas, I.; de-la-Mora, R.; Miranda, A. A.; Plazas, M.-C.; Betancourt, C.-M.; Borras, C.
2001-10-01
Under the auspices of PAHO/WHO, a multicentric investigation is carried out in five Latin American countries. Its aim is to correlate quality indicators of radiology services with the accuracy of the radiological interpretation as determined by a panel of radiology experts. We present preliminary results from mammographic imaging facilities. Evaluation of the equipment performance and dose measurements in 21 mammographic units show that, on the average, 75% of the units comply with recommendations issued by various organizations. An independent evaluation of the quality of the clinical images show strong variations among the different radiological services.
Radiation dose to physicians’ eye lens during interventional radiology
NASA Astrophysics Data System (ADS)
Bahruddin, N. A.; Hashim, S.; Karim, M. K. A.; Sabarudin, A.; Ang, W. C.; Salehhon, N.; Bakar, K. A.
2016-03-01
The demand of interventional radiology has increased, leading to significant risk of radiation where eye lens dose assessment becomes a major concern. In this study, we investigate physicians' eye lens doses during interventional procedures. Measurement were made using TLD-100 (LiF: Mg, Ti) dosimeters and was recorded in equivalent dose at a depth of 0.07 mm, Hp(0.07). Annual Hp(0.07) and annual effective dose were estimated using workload estimation for a year and Von Boetticher algorithm. Our results showed the mean Hp(0.07) dose of 0.33 mSv and 0.20 mSv for left and right eye lens respectively. The highest estimated annual eye lens dose was 29.33 mSv per year, recorded on left eye lens during fistulogram procedure. Five physicians had exceeded 20 mSv dose limit as recommended by international commission of radiological protection (ICRP). It is suggested that frequent training and education on occupational radiation exposure are necessary to increase knowledge and awareness of the physicians’ thus reducing dose during the interventional procedure.
Lai, Priscilla; McNeil, Sarah M; Gordon, Christopher L; Connolly, Bairbre L
2014-12-01
The purpose of this study was to determine the range of effective doses associated with imaging techniques used during interventional radiology procedures on children. A pediatric phantom set (1, 5, and 10 years) coupled with high-sensitivity metal oxide semiconductor field effect transistor (MOSFET) dosimeters was used to calculate effective doses. Twenty MOSFETs were inserted into each phantom at radiosensitive organ locations. The phantoms were exposed to mock head, chest, and abdominal interventional radiology procedures performed with different geometries and magnifications. Fluoroscopy, digital subtraction angiography (DSA), and spin angiography were simulated on each phantom. Road mapping was conducted only on the 5-year-old phantom. International Commission on Radiological Protection publication 103 tissue weights were applied to the organ doses recorded with the MOSFETs to determine effective dose. For easy application to clinical cases, doses were normalized per minute of fluoroscopy and per 10 frames of DSA or spin angiography. Effective doses from DSA, angiography, and fluoroscopy were higher for younger ages because of magnification use and were largest for abdominal procedures. DSA of the head, chest, and abdomen (normalized per 10 frames) imparted doses 2-3 times as high as corresponding doses per minute of fluoroscopy while all other factors remained unchanged (age, projection, collimation, magnification). Three to five frames of DSA imparted an effective dose equal to doses from 1 minute of fluoroscopy. Doses from spin angiography were almost one-half the doses received from an equivalent number of frames of DSA. Patient effective doses during interventional procedures vary substantially depending on procedure type but tend to be higher because of magnification use in younger children and higher in the abdomen.
NASA Astrophysics Data System (ADS)
Abed Gatea, Mezher; Ahmed, Anwar A.; jundee kadhum, Saad; Ali, Hasan Mohammed; Hussein Muheisn, Abbas
2018-05-01
The Safety Assessment Framework (SAFRAN) software has implemented here for radiological safety analysis; to verify that the dose acceptance criteria and safety goals are met with a high degree of confidence for dismantling of Tammuz-2 reactor core at Al-tuwaitha nuclear site. The activities characterizing, dismantling and packaging were practiced to manage the generated radioactive waste. Dose to the worker was considered an endpoint-scenario while dose to the public has neglected due to that Tammuz-2 facility is located in a restricted zone and 30m berm surrounded Al-tuwaitha site. Safety assessment for dismantling worker endpoint-scenario based on maximum external dose at component position level in the reactor pool and internal dose via airborne activity while, for characterizing and packaging worker endpoints scenarios have been done via external dose only because no evidence for airborne radioactivity hazards outside the reactor pool. The in-situ measurements approved that reactor core components are radiologically activated by Co-60 radioisotope. SAFRAN results showed that the maximum received dose for workers are (1.85, 0.64 and 1.3mSv/y) for activities dismantling, characterizing and packaging of reactor core components respectively. Hence, the radiological hazards remain below the low level hazard and within the acceptable annual dose for workers in radiation field
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coruh, M; Ewell, L; Demez, N
Purpose: To estimate the dose delivered to a moving lung tumor by proton therapy beams of different modulation types, and compare with Monte Carlo predictions. Methods: A radiology support devices (RSD) phantom was irradiated with therapeutic proton radiation beams using two different types of modulation: uniform scanning (US) and double scattered (DS). The Eclipse© dose plan was designed to deliver 1.00Gy to the isocenter of a static ∼3×3×3cm (27cc) tumor in the phantom with 100% coverage. The peak to peak amplitude of tumor motion varied from 0.0 to 2.5cm. The radiation dose was measured with an ion-chamber (CC-13) located withinmore » the tumor. The time required to deliver the radiation dose varied from an average of 65s for the DS beams to an average of 95s for the US beams. Results: The amount of radiation dose varied from 100% (both US and DS) to the static tumor down to approximately 92% for the moving tumor. The ratio of US dose to DS dose ranged from approximately 1.01 for the static tumor, down to 0.99 for the 2.5cm moving tumor. A Monte Carlo simulation using TOPAS included a lung tumor with 4.0cm of peak to peak motion. In this simulation, the dose received by the tumor varied by ∼40% as the period of this motion varied from 1s to 4s. Conclusion: The radiation dose deposited to a moving tumor was less than for a static tumor, as expected. At large (2.5cm) amplitudes, the DS proton beams gave a dose closer to the desired dose than the US beams, but equal within experimental uncertainty. TOPAS Monte Carlo simulation can give insight into the moving tumor — dose relationship. This work was supported in part by the Philips corporation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
McLaughlin, David A; Schwahn, Scott O
2011-01-01
While inhalation dose coefficients are provided for about 800 radionuclides in International Commission on Radiological Protection (ICRP) Publication 68, many radionuclides of practical dosimetric interest for facilities such as high-energy proton accelerators are not specifically addressed, nor are organ-specific dose coefficients tabulated. The ICRP Publication 68 methodology is used, along with updated radiological decay data and metabolic data, to identify committed equivalent dose coefficients [hT(50)] and committed effective dose coefficients [e(50)] for radionuclides produced at the Oak Ridge National Laboratory s Spallation Neutron Source.
Rühm, Werner; Azizova, Tamara; Bouffler, Simon; Cullings, Harry M; Grosche, Bernd; Little, Mark P; Shore, Roy S; Walsh, Linda; Woloschak, Gayle E
2018-01-01
Abstract In order to quantify radiation risks at exposure scenarios relevant for radiation protection, often extrapolation of data obtained at high doses and high dose rates down to low doses and low dose rates is needed. Task Group TG91 on ‘Radiation Risk Inference at Low-dose and Low-dose Rate Exposure for Radiological Protection Purposes’ of the International Commission on Radiological Protection is currently reviewing the relevant cellular, animal and human studies that could be used for that purpose. This paper provides an overview of dose rates and doses typically used or present in those studies, and compares them with doses and dose rates typical of those received by the A-bomb survivors in Japan. PMID:29432579
Radiological assessment. A textbook on environmental dose analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Till, J.E.; Meyer, H.R.
1983-09-01
Radiological assessment is the quantitative process of estimating the consequences to humans resulting from the release of radionuclides to the biosphere. It is a multidisciplinary subject requiring the expertise of a number of individuals in order to predict source terms, describe environmental transport, calculate internal and external dose, and extrapolate dose to health effects. Up to this time there has been available no comprehensive book describing, on a uniform and comprehensive level, the techniques and models used in radiological assessment. Radiological Assessment is based on material presented at the 1980 Health Physics Society Summer School held in Seattle, Washington. Themore » material has been expanded and edited to make it comprehensive in scope and useful as a text. Topics covered include (1) source terms for nuclear facilities and Medical and Industrial sites; (2) transport of radionuclides in the atmosphere; (3) transport of radionuclides in surface waters; (4) transport of radionuclides in groundwater; (5) terrestrial and aquatic food chain pathways; (6) reference man; a system for internal dose calculations; (7) internal dosimetry; (8) external dosimetry; (9) models for special-case radionuclides; (10) calculation of health effects in irradiated populations; (11) evaluation of uncertainties in environmental radiological assessment models; (12) regulatory standards for environmental releases of radionuclides; (13) development of computer codes for radiological assessment; and (14) assessment of accidental releases of radionuclides.« less
The mandate and work of ICRP Committee 3 on radiological protection in medicine.
Miller, D L; Martin, C J; Rehani, M M
2018-01-01
The mandate of Committee 3 of the International Commission on Radiological Protection (ICRP) is concerned with the protection of persons and unborn children when ionising radiation is used in medical diagnosis, therapy, and biomedical research. Protection in veterinary medicine has been newly added to the mandate. Committee 3 develops recommendations and guidance in these areas. The most recent documents published by ICRP that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (ICRP Publication 129) and 'Radiological protection in ion beam radiotherapy' (ICRP Publication 127). A report in cooperation with ICRP Committee 2 entitled 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (ICRP Publication 128) has also been published. 'Diagnostic reference levels in medical imaging' (ICRP Publication 135), published in 2017, provides specific advice on the setting and use of diagnostic reference levels for diagnostic and interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and multi-modality procedures. 'Occupational radiological protection in interventional procedures' was published in March 2018 as ICRP Publication 139. A document on radiological protection in therapy with radiopharmaceuticals is likely to be published in 2018. Work is in progress on several other topics, including appropriate use of effective dose in collaboration with the other ICRP committees, guidance for occupational radiological protection in brachytherapy, justification in medical imaging, and radiation doses to patients from radiopharmaceuticals (an update to ICRP Publication 128). Committee 3 is also considering the development of guidance on radiological protection in medicine related to individual radiosusceptibility, in collaboration with ICRP Committee 1.
Yoshikawa, Hiroto; Roback, Donald M; Larue, Susan M; Nolan, Michael W
2015-01-01
Potential benefits of planning radiation therapy on a contrast-enhanced computed tomography scan (ceCT) should be weighed against the possibility that this practice may be associated with an inadvertent risk of overdosing nearby normal tissues. This study investigated the influence of ceCT on intensity-modulated stereotactic body radiotherapy (IM-SBRT) planning. Dogs with head and neck, pelvic, or appendicular tumors were included in this retrospective cross-sectional study. All IM-SBRT plans were constructed on a pre- or ceCT. Contours for tumor and organs at risk (OAR) were manually constructed and copied onto both CT's; IM-SBRT plans were calculated on each CT in a manner that resulted in equal radiation fluence. The maximum and mean doses for OAR, and minimum, maximum, and mean doses for targets were compared. Data were collected from 40 dogs per anatomic site (head and neck, pelvis, and limbs). The average dose difference between minimum, maximum, and mean doses as calculated on pre- and ceCT plans for the gross tumor volume was less than 1% for all anatomic sites. Similarly, the differences between mean and maximum doses for OAR were less than 1%. The difference in dose distribution between plans made on CTs with and without contrast enhancement was tolerable at all treatment sites. Therefore, although caution would be recommended when planning IM-SBRT for tumors near "reservoirs" for contrast media (such as the heart and urinary bladder), findings supported the use of ceCT with this dose calculation algorithm for both target delineation and IM-SBRT treatment planning. © 2015 American College of Veterinary Radiology.
Radiological Monitoring for Instructors. Student Workbook. Revised.
ERIC Educational Resources Information Center
Office of Civil Defense (DOD), Washington, DC.
This student workbook includes the necessary materials and some of the references needed by each student during the conduct of the Radiological Monitoring for Instructors (RMI) course. The contents include a radiation exposure record, instrument exercise materials, fallout forecasting problems, dose and dose rate problems, source handling…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maclean, Jillian, E-mail: jillian.maclean@uclh.nhs.uk; Fersht, Naomi; Bremner, Fion
2013-03-15
Purpose: To evaluate ophthalmologic outcomes and toxicity of intensity modulated radiation therapy (IMRT) in patients with meningiomas causing visual deficits. Methods and Materials: A prospective observational study with formal ophthalmologic and clinical assessment of 30 consecutive cases of meningioma affecting vision treated with IMRT from 2007 to 2011. Prescriptions were 50.4 Gy to mean target dose in 28 daily fractions. The median follow-up time was 28 months. Twenty-six meningiomas affected the anterior visual pathway (including 3 optic nerve sheath meningiomas); 4 were posterior to the chiasm. Results: Vision improved objectively in 12 patients (40%). Improvements were in visual field (5/16more » patients), color vision (4/9 patients), acuity (1/15 patients), extraocular movements (3/11 patients), ptosis (1/5 patients), and proptosis (2/6 patients). No predictors of clinical response were found. Two patients had minor reductions in tumor dimensions on magnetic resonance imaging, 1 patient had radiological progression, and the other patients were stable. One patient experienced grade 2 keratitis, 1 patient had a minor visual field loss, and 5 patients had grade 1 dry eye. Conclusion: IMRT is an effective method for treating meningiomas causing ophthalmologic deficits, and toxicity is minimal. Thorough ophthalmologic assessment is important because clinical responses often occur in the absence of radiological change.« less
NASA Astrophysics Data System (ADS)
Staton, Robert J.
Of the various types of imaging modalities used in pediatric radiology, fluoroscopy and computed tomography (CT) have the highest associated radiation dose. While these examinations are commonly used for pediatric patients, little data exists on the magnitude of the organ and effective dose values for these procedures. Calculation of these dose values is necessary because of children's increased sensitivity to radiation and their long life expectancy for which to express radiation's latent effects. In this study, a newborn tomographic phantom has been implemented in a radiation transport code to evaluate organ and effective doses for newborn patients in commonly performed fluoroscopy and CT examinations. Organ doses were evaluated for voiding cystourethrogram (VCUG) fluoroscopy studies of infant patients. Time-sequence analysis was performed for videotaped VCUG studies of five different patients. Organ dose values were then estimated for each patient through Monte Carlo (MC) simulations. The effective dose values of the VCUG examination for five patients ranged from 0.6 mSv to 3.2 mSv, with a mean of 1.8 +/- 0.9 mSv. Organ doses were also assessed for infant upper gastrointestinal (UGI) fluoroscopy exams. The effective dose values of the UGI examinations for five patients ranged from 1.05 mSv to 5.92 mSv, with a mean of 2.90 +/- 1.97 mSv. MC simulations of helical multislice CT (MSCT) exams were also completed using, the newborn tomographic phantom and a stylized newborn phantom. The helical path of the source, beam shaping filter, beam profile, patient table, were all included in the MC simulations of the helical MSCT scanner. Organ doses and effective doses and their dependence on scan parameters were evaluated for newborn patients. For all CT scans, the effective dose was found to range approximately 1-13 mSv, with the largest values occurring for CAP scans. Tube current modulation strategies to reduce patient dose were also evaluated for newborn patients. Overall, utilization of the newborn tomographic phantom in MC simulations has shown the need for and usefulness of pediatric tomographic phantoms. The newborn tomographic model has shown more versatility and realistic anatomical modeling when compared to the existing stylized newborn phantom. This work has provided important organ dose data for infant patients in common examinations in pediatric radiology.
Comparison of the radiological and chemical toxicity of lead
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beitel, G.A.; Mott, S.
1995-03-01
This report estimates the worst-case radiological dose to an individual from ingested lead containing picocurie levels of radionuclides and then compares the calculated radiological health effects to the chemical toxic effects from that same lead. This comparison provides an estimate of the consequences of inadvertently recycling, in the commercial market, lead containing nominally undetectable concentrations of radionuclides. Quantitative expressions for the radiological and chemical toxicities of lead are based on concentrations of lead in the blood stream. The result shows that the chemical toxicity of lead is a greater health hazard, by orders of magnitude, than any probable companion radiationmore » dose.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
PIERSON, R.M.
1999-10-27
This document provides the technical basis for use of remote reading capabilities with radiological control instruments at River Protection Project facilities. The purpose of this document is to evaluate applications of remote reading capabilities with Radiological Control instrumentation to allow continuous monitoring of radiation dose rates at River Protection Project (RPP) facilities. In addition this document provides a technical basis and implementing guidelines for remote monitoring of dose rates and their potential contribution to maintaining radiation exposures ALARA.
Radiation exposure in interventional radiology
NASA Astrophysics Data System (ADS)
Pinto, N. G. V.; Braz, D.; Vallim, M. A.; Filho, L. G. P.; Azevedo, F. S.; Barroso, R. C.; Lopes, R. T.
2007-09-01
The aim of this study is to evaluate dose values in patients and staff involved in some interventional radiology procedures. Doses have been measured using thermoluminescent dosemeters for single procedures (such as renal and cerebral arteriography, transjungular intrahepatic portasystemic shunt (TIPS) and chemoembolization). The magnitude of doses through the hands of interventional radiologists has been studied. Dose levels were evaluated in three points for patients (eye, thyroid and gonads). The dose-area product (DAP) was also investigated using a Diamentor (PTW-M2). The dose in extremities was estimated for a professional who generally performed one TIPS, two chemoembolizations, two cerebral arteriographies and two renal arteriographies in a week. The estimated annual radiation dose was converted to effective dose as suggested by the 453-MS/Brazil norm The annual dose values were 137.25 mSv for doctors, 40.27 mSv for nurses and 51.95 mSv for auxiliary doctors, and all these annual dose values are below the limit established. The maximum values of the dose obtained for patients were 6.91, 10.92 and 15.34 mGy close to eye, thyroid and gonads, respectively. The DAP values were evaluated for patients in the same interventional radiology procedures. The dose and DAP values obtained are in agreement with values encountered in the literature.
Topical Review: Polymer gel dosimetry
Baldock, C; De Deene, Y; Doran, S; Ibbott, G; Jirasek, A; Lepage, M; McAuley, K B; Oldham, M; Schreiner, L J
2010-01-01
Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. PMID:20150687
Dose and risk in diagnostic radiology: How big How little Lecture Number 16
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webster, E.W.
1992-01-01
This lecture is divided into two parts: dose and risk. The dose segment is technical and noncontroversial since it deals with straightforward measurements or calculations which do not depend on unproven hypotheses. Some conflicting contributions of low dose epidemiological studies to the appraisal of risk are briefly presented. Attention is focused on the following: dose reduction in radiography; dose reduction in fluoroscopy; limitations of dose reduction; estimated radiation risks for diagnostic radiology examinations; excess breast cancer following X-ray examinations for scoliosis; dose-response relation for human mammary cancer; lung cancer from protracted X-irradiation; leukemia and diagnostic X-ray exposure; and thyroid cancermore » after diagnostic dose of I-131.« less
LETTER TO THE EDITOR: Response to 'Patient dose measurements in radiological practices'
NASA Astrophysics Data System (ADS)
Zoetelief, J.; Wambersie, A.
2006-06-01
A lack of suitable dosimetric quantities for application in diagnostic radiology is noted by Dr Moores. It is concluded by Dr Moores that it is not possible to adhere to the basic principles of the International Commission on Radiation Units and Measurements (ICRU) regarding patient dosimetry in diagnostic radiology due to the extremely wide variety of quantities and units employed. The conclusion of the ICRU on similar observations, however, was that there is a need for harmonization of quantities and terminology for dosimetry in diagnostic and interventional radiology and they established a Report Committee with the aim of formulating an ICRU report on 'dosimetric procedures in diagnostic radiology'. The report produced by this committee entitled 'Patient dosimetry for x rays used in medical imaging' was accepted for publication in December 2005 and is currently at press, and may serve to improve the current situation with regard to patient dose measurement in diagnostic and interventional radiology.
Retrouvey, Michele; Trace, Anthony Paul; Goodmurphy, Craig W; Shaves, Sarah
2018-01-01
Radiology interconnects medical disciplines given that a working understanding of imaging is essential to clinicians of every specialty. Using online education, we created a globally accessible, web-based undergraduate medical radiology curriculum modeled after the National Medical Student Curriculum in Radiology program of the Alliance of Medical Student Educators in Radiology. Seventy-four radiology faculty-mentored video modules were produced, 50 of which were integrated into the 1st-year anatomy course. We administered tests to medical students before and after students saw the videos to assess the effectiveness of the modules. We surveyed students on their interests in pursuing radiology as a career before and after participating in this curriculum. On the preexamination questions, the mean score was 58.0%, which increased to 83.6% on the pair-matched imaging-related questions on the actual examination. Before participating in the new curriculum, 88% of students did not express an interest in radiology, and 9% were undecided about radiology as a future career. There was an increase in students who reported that they would definitely or most likely pursue a career in radiology (7%) after they had viewed the lectures. Radiology education is now available to a greater number of multidisciplinary learners worldwide. This project produced a comprehensive, globally accessible radiology curriculum in a self-paced, flexible learning format for new generations of physicians.
Radiological impact of airborne effluents of coal and nuclear plants.
McBride, J P; Moore, R E; Witherspoon, J P; Blanco, R E
1978-12-08
Radiation doses from airborne effluents of model coal-fired and nuclear power plants (1000 megawatts electric) are compared. Assuming a 1 percent ash release to the atmosphere (Environmental Protection Agency regulation) and 1 part per million of uranium and 2 parts per million of thorium in the coal (approximately the U.S. average), population doses from the coal plant are typically higher than those from pressurized-water or boiling-water reactors that meet government regulations. Higher radionuclide contents and ash releases are common and would result in increased doses from the coal plant. The study does not assess the impact of non-radiological pollutants or the total radiological impacts of a coal versus a nuclear economy.
Omar, Artur; Kadesjö, Nils; Palmgren, Charlotta; Marteinsdottir, Maria; Segerdahl, Tony; Fransson, Annette
2017-03-20
In accordance with recommendations by the International Commission on Radiological Protection, the current European Basic Safety Standards has adopted a reduced occupational eye lens dose limit of 20 mSv yr -1 . The radiation safety implications of this dose limit is of concern for clinical staff that work with relatively high dose x-ray angiography and interventional radiology. Presented in this work is a thorough assessment of the occupational eye lens dose based on clinical measurements with active personal dosimeters worn by staff during various types of procedures in interventional radiology, cardiology and neuroradiology. Results are presented in terms of the estimated equivalent eye lens dose for various medical professions. In order to compare the risk of exceeding the regulatory annual eye lens dose limit for the widely different clinical situations investigated in this work, the different medical professions were separated into categories based on their distinct work pattern: staff that work (a) regularly beside the patient, (b) in proximity to the patient and (c) typically at a distance from the patient. The results demonstrate that the risk of exceeding the annual eye lens dose limit is of concern for staff category (a), i.e. mainly the primary radiologist/cardiologist. However, the results also demonstrate that the risk can be greatly mitigated if radiation protection shields are used in the clinical routine. The results presented in this work cover a wide range of clinical situations, and can be used as a first indication of the risk of exceeding the annual eye lens dose limit for staff at other medical centres.
Bacchim Neto, Fernando Antonio; Alves, Allan Felipe Fattori; Mascarenhas, Yvone Maria; Nicolucci, Patrícia; Pina, Diana Rodrigues de
2016-08-01
To perform a complete evaluation on radiation doses, received by primary and assistant medical staff, while performing different vascular interventional radiology procedures. We evaluated dose received in different body regions during three categories of vascular procedures: lower limb angiography (Angiography), lower limb percutaneous transluminal angioplasty (Angioplasty) and stent graft placement for abdominal aortic aneurysm treatment (A. A. A. Treatment). We positioned the dosimeters near the eye lens, thyroid, chest, abdomen, hands, and feet of the interventional physicians. Equivalent dose was compared with annual dose limits for workers in order to determine the maximum number of procedures per year that each physician could perform. We assessed 90 procedures. We found the highest equivalent doses in the A. A. A. Treatment, in which 90% of the evaluations indicated at least one region receiving more than 1mSv per procedure. Angioplasty was the only procedural modality that provided statistically different doses for different professionals, which is an important aspect on regards to radiological protection strategies. In comparison with the dose limits, the most critical region in all procedures was the eye lens. Since each body region of the interventionist is exposed to different radiation levels, dose distribution measurements are essential for radiological protection strategies. These results indicate that dosimeters placed in abdomen instead of chest may represent more accurately the whole body doses received by the medical staff. Additional dosimeters and a stationary shield for the eye lens are strongly recommended. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Jones, Alison; Jones, Kelly; Holmes, Sheila; Ewers, Leon; Cabianca, Tiberio
2013-03-01
The aim of this work is to assess the possible radiological impact on the population of the United Kingdom (UK) from new nuclear power stations proposed for up to eight sites in England and Wales. The radiological impact was measured in terms of collective dose to the UK, European and world populations from a single year's discharge integrated to 500 and 100 000 years and the annual dose to an average member of the UK population (known as the per-caput dose). The doses were calculated for two reactor types, UK EPR™ and AP1000™, using the annual expected discharges estimated by the designers of the reactors and assuming two reactors per site. In addition, typical individual doses to adults living close to the sites were calculated on the basis of continuous discharges for 60 years (the assumed lifetime of the reactors). The dose to a representative person (previously known as the critical group) was not calculated, as this has been done elsewhere. The assessments were carried out using the software program PC-CREAM 08(®) which implements the updated European Commission methodology for assessing the radiological impact of routine releases of radionuclides to the environment. The collective dose truncated to 500 years to the UK population was estimated to be 0.5 manSv assuming UK EPR reactors on all sites and 0.6 manSv assuming AP1000s on three sites with UK EPRs on the other sites. The most significant contribution to the collective dose to the UK population is due to the global circulation of carbon-14 released to the atmosphere. The annual dose to an average member of the UK population from all sites was calculated to be around 10 nSv y(-1) and would therefore contribute little to an individual's total radiation dose. All the calculated doses to a typical adult living near the sites assuming continuous discharges for 60 years were found to be below 1 μSv y(-1).
Feasibility of a semiconductor dosimeter to monitor skin dose in interventional radiology.
Meyer, P; Regal, R; Jung, M; Siffert, P; Mertz, L; Constantinesco, A
2001-10-01
The design and preliminary test results of a semiconductor silicon dosimeter are presented in this article. Use of this dosimeter is foreseen for real-time skin dose control in interventional radiology. The strong energy dependence of this kind of radiation detector is well overcome by filtering the silicon diode. Here, the optimal filter features have been calculated by numerical Monte Carlo simulations. A prototype has been built and tested in a radiological facility. The first experimental results show a good match between the filtered semiconductor diode response and an ionization chamber response, within 2% fluctuation in a 2.2 to 4.1 mm Al half-value layer (HVL) energy range. Moreover, the semiconductor sensor response is linear from 0.02 Gy/min to at least 6.5 Gy/min, covering the whole dose rate range found in interventional radiology. The results show that a semiconductor dosimeter could be used to monitor skin dose during the majority of procedures using x-rays below 150 keV. The use of this device may assist in avoiding radiation-induced skin injuries and lower radiation levels during interventional procedures.
Myers, Michael A; Hagan, Michael P; Todor, Dorin; Gilbert, Lynn; Mukhopadhyay, Nitai; Randolf, Jessica; Heimiller, Jeffrey; Anscher, Mitchell S
2012-01-01
A Phase I/II protocol was conducted to examine the toxicity and efficacy of the combination of intensity-modulated radiation therapy (IMRT) with a single-fraction high-dose-rate (HDR) brachytherapy implant. From 2001 through 2006, 26 consecutive patients were treated on the trial. The primary objective was to demonstrate a high rate of completion without experiencing a treatment-limiting toxicity. Eligibility was limited to patients with T stage ≤2b, prostate-specific antigen (PSA) ≤20, and Gleason score ≤7. Treatment began with a single HDR fraction of 6Gy to the entire prostate and 9Gy to the peripheral zone, followed by IMRT optimized to deliver in 28 fractions with a normalized total dose of 70Gy. Patients received 50.4Gy to the pelvic lymph node. The prostate dose (IMRT and HDR) resulted in an average biologic equivalent dose >128Gy (α/β=3). Patients whose pretreatment PSA was ≥10ng/mL, Gleason score 7, or stage ≥T2b received short-term androgen ablation. Median followup was 53 months (9-68 months). There were no biochemical failures by either the American Society of Therapeutic Radiology and Oncology or the Phoenix definitions. The median nadir PSA was 0.32ng/mL. All the 26 patients completed the treatment as prescribed. The rate of Grade 3 late genitourinary toxicity was 3.8% consisting of a urethral stricture. There was no other Grade 3 or 4 genitourinary or gastrointestinal toxicities. Single-fraction HDR-boosted IMRT is a safe effective method of dose escalation for localized prostate cancer. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Divrik Gökçe, Senem; Coşkun, Melek
2012-01-01
Objective Imaging methods that use ionizing radiation have been more frequent in various medical fields with advances in imaging technology. The aim of our study was to make residents be aware of the radiation dose they are subjected to when they conduct radiological imaging methods, and of cancer risk. Materials and Methods A total of 364 residents participated in this descriptive study which was conducted during the period between October, 2008 and January, 2009. The questionnaires were completed under strict control on a one-to-one basis from each department. A χ2-test was used for the evaluation of data obtained. Results Only 7% of residents correctly answered to the question about the ionizing radiation dose of a posteroanterior (PA) chest X-ray. The question asking about the equivalent number of PA chest X-rays to the ionizing dose of a brain CT was answered correctly by 24% of residents; the same question regarding abdominal CT was answered correctly by 16% of residents, thorax CT by 16%, thyroid scintigraphy by 15%, intravenous pyelography by 9%, and lumbar spine radiography by 2%. The risk of developing a cancer throughout lifetime by a brain and abdominal CT were 33% and 28%, respectively. Conclusion Radiologic residents should have updated knowledge about radiation dose content and attendant cancer risks of various radiological imaging methods during both basic medical training period and following practice period. PMID:22438688
Improved understanding of human anatomy through self-guided radiological anatomy modules.
Phillips, Andrew W; Smith, Sandy G; Ross, Callum F; Straus, Christopher M
2012-07-01
To quantifiably measure the impact of self-instructed radiological anatomy modules on anatomy comprehension, demonstrated by radiology, gross, and written exams. Study guides for independent use that emphasized structural relationships were created for use with two online radiology atlases. A guide was created for each module of the first year medical anatomy course and incorporated as an optional course component. A total of 93 of 96 eligible students participated. All exams were normalized to control for variances in exam difficulty and body region tested. An independent t-test was used to compare overall exam scores with respect to guide completion or incompletion. To account for aptitude differences between students, a paired t-test of each student's exam scores with and without completion of the associated guide was performed, thus allowing students to serve as their own controls. Twenty-one students completed no study guides; 22 completed all six guides; and 50 students completed between one and five guides. Aggregate comparisons of all students' exam scores showed significantly improved mean performance when guides were used (radiology, 57.8% [percentile] vs. 45.1%, P < .001; gross, 56.9% vs. 46.5%, P = .001; written, 57.8% vs. 50.2%, P = .011). Paired comparisons among students who completed between one and five guides demonstrated significantly higher mean practical exam scores when guides were used (radiology, 49.3% [percentile] vs. 36.0%, P = .001; gross, 51.5% vs. 40.4%, P = .005), but not higher written scores. Radiological anatomy study guides significantly improved anatomy comprehension on radiology, gross, and written exams. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
Carpeggiani, Clara; Picano, Eugenio
2016-06-01
Every radiological and nuclear medicine examination confers a definite long-term risk of cancer, but most patients undergoing such examinations receive no or inaccurate information about radiation dose and corresponding risk related to the dose received. Informed consent is a procedure to support (not substitute) the physician/patient dialogue and relationship, facilitating a free, informed and aware expression of the patient's will in the principle of patient autonomy. Physicians are responsible for providing patients with all the information on risks, benefits and alternatives useful to the patient to make the decision. In current radiological practice the information on the radiation dose and long-term cancer risks is difficult to find and not easy to understand. The form using plain language should spell-out the type of examination, the effective dose (mSv), the effective dose expressed in number of chest radiographs and the risk of cancer. The current practice clashes against the guidelines and the law.
Remote Handled WIPP Canisters at Los Alamos National Laboratory Characterized for Retrieval
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffin, J.; Gonzales, W.
2007-07-01
The Los Alamos National Laboratory (LANL) is pursuing retrieval, transportation, and disposal of 16 remote handled transuranic waste canisters stored below ground in shafts since 1994. These canisters were retrievably stored in the shafts to await Nuclear Regulatory Commission certification of the Model Number RH-TRU 72B transportation cask and authorization of the Waste Isolation Pilot Plant (WIPP) to accept the canisters for disposal. Retrieval planning included radiological characterization and visual inspection of the canisters to confirm historical records, verify container integrity, determine proper personnel protection for the retrieval operations, provide radiological dose and exposure rate data for retrieval operations, andmore » to provide exterior radiological contamination data. The radiological characterization and visual inspection of the canisters was performed in May 2006. The effort required the development of remote techniques and equipment due to the potential for personnel exposure to radiological doses approaching 300 R/hr. Innovations included the use of two nested 1.5 meter (m) (5-feet [ft]) long concrete culvert pipes (1.1-m [42 inch (in.)] and 1.5-m [60-in] diameter, respectively) as radiological shielding and collapsible electrostatic dusting wands to collect radiological swipe samples from the annular space between the canister and shaft wall. Visual inspection indicated that the canisters are in good condition with little or no rust, the welded seams are intact, and ten of the canisters include hydrogen gas sampling equipment on the pintle that will have to be removed prior to retrieval. The visual inspection also provided six canister identification numbers that matched historical storage records. The exterior radiological data indicated alpha and beta contamination below LANL release criteria and radiological dose and exposure rates lower than expected based upon historical data and modeling of the canister contents. (authors)« less
NASA Astrophysics Data System (ADS)
Antoniou, P. E.; Bousbouras, P.; Sandaltzopoulos, R.; Kaldoudi, E.
2008-04-01
Complex interventional radiology (IR) procedures contribute an increasing percentage of the overall medical radiation exposure of the population making accurate dosimetry a challenge. Magnetic resonance (MR) based polymer gel dosimetry has been widely employed in complex dosimetric problems in radiotherapy. The aim of this note is to investigate the feasibility of normoxic gel dosimetry in IR. Dose response, energy dependence and dose rate dependence were investigated in irradiation set-ups relevant to IR for a particular normoxic gel, based on methacrylic acid (MAA) as the monomer and including tetrakis-hydroxy-methyl-phosphonium chloride (THPC) as antioxidant. The gel presents a linear dose response beyond a 25 cGy threshold. No significant energy dependence was observed in the useful range of interventional radiology (80-110 kVp). A linear correlation between the gel response and dose rate was observed in the range of dose rates relevant to IR (5-8 cGy min-1). These results demonstrate a reduction of gel sensitivity at very low dose rate levels. A possible explanation of this effect is suggested.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oliver, Mike; Gladwish, Adam; Craig, Jeff
2008-07-15
Purpose and background: Intensity modulated arc therapy (IMAT) is a rotational variant of Intensity modulated radiation therapy (IMRT) that is achieved by allowing the multileaf collimator (MLC) positions to vary as the gantry rotates around the patient. This work describes a method to generate an IMAT plan through the use of a fast ray tracing technique based on dosimetric and geometric information for setting initial MLC leaf positions prior to final IMAT optimization. Methods and materials: Three steps were used to generate an IMAT plan. The first step was to generate arcs based on anatomical contours. The second step wasmore » to generate ray importance factor (RIF) maps by ray tracing the dose distribution inside the planning target volume (PTV) to modify the MLC leaf positions of the anatomical arcs to reduce the maximum dose inside the PTV. The RIF maps were also segmented to create a new set of arcs to improve the dose to low dose voxels within the PTV. In the third step, the MLC leaf positions from all arcs were put through a leaf position optimization (LPO) algorithm and brought into a fast Monte Carlo dose calculation engine for a final dose calculation. The method was applied to two phantom cases, a clinical prostate case and the Radiological Physics Center (RPC)'s head and neck phantom. The authors assessed the plan improvements achieved by each step and compared plans with and without using RIF. They also compared the IMAT plan with an IMRT plan for the RPC phantom. Results: All plans that incorporated RIF and LPO had lower objective function values than those that incorporated LPO only. The objective function value was reduced by about 15% after the generation of RIF arcs and 52% after generation of RIF arcs and leaf position optimization. The IMAT plan for the RPC phantom had similar dose coverage for PTV1 and PTV2 (the same dose volume histogram curves), however, slightly lower dose to the normal tissues compared to a six-field IMRT plan. Conclusion: The use of a ray importance factor can generate initial IMAT arcs efficiently for further MLC leaf position optimization to obtain more favorable IMAT plan.« less
Influence of physical parameters on radiation protection and image quality in intra-oral radiology
NASA Astrophysics Data System (ADS)
Belinato, W.; Souza, D. N.
2011-10-01
In the world of diagnostic imaging, radiography is an important supplementary method for dental diagnosis. In radiology, special attention must be paid to the radiological protection of patients and health professionals, and also to image quality for correct diagnosis. In Brazil, the national rules governing the operation of medical and dental radiology were specified in 1998 by the National Sanitary Surveillance Agency, complemented in 2005 by the guide "Medical radiology: security and performance of equipment." In this study, quality control tests were performed in public clinics with dental X-ray equipment in the State of Sergipe, Brazil, with consideration of the physical parameters that influence radiological protection and also the quality of images taken in intra-oral radiography. The accuracy of the exposure time was considered acceptable for equipment with digital timers. Exposure times and focal-spot size variations can lead to increased entrance dose. Increased dose has also been associated with visual processing of radiographic film, which often requires repeating the radiographic examination.
Miksys, Nelson; Gordon, Christopher L; Thomas, Karen; Connolly, Bairbre L
2010-05-01
The purpose of this study was to estimate the effective doses received by pediatric patients during interventional radiology procedures and to present those doses in "look-up tables" standardized according to minute of fluoroscopy and frame of digital subtraction angiography (DSA). Organ doses were measured with metal oxide semiconductor field effect transistor (MOSFET) dosimeters inserted within three anthropomorphic phantoms, representing children at ages 1, 5, and 10 years, at locations corresponding to radiosensitive organs. The phantoms were exposed to mock interventional radiology procedures of the head, chest, and abdomen using posteroanterior and lateral geometries, varying magnification, and fluoroscopy or DSA exposures. Effective doses were calculated from organ doses recorded by the MOSFET dosimeters and are presented in look-up tables according to the different age groups. The largest effective dose burden for fluoroscopy was recorded for posteroanterior and lateral abdominal procedures (0.2-1.1 mSv/min of fluoroscopy), whereas procedures of the head resulted in the lowest effective doses (0.02-0.08 mSv/min of fluoroscopy). DSA exposures of the abdomen imparted higher doses (0.02-0.07 mSv/DSA frame) than did those involving the head and chest. Patient doses during interventional procedures vary significantly depending on the type of procedure. User-friendly look-up tables may provide a helpful tool for health care providers in estimating effective doses for an individual procedure.
NASA Astrophysics Data System (ADS)
Barufaldi, Bruno; Lau, Kristen C.; Schiabel, Homero; Maidment, D. A.
2015-03-01
Routine performance of basic test procedures and dose measurements are essential for assuring high quality of mammograms. International guidelines recommend that breast care providers ascertain that mammography systems produce a constant high quality image, using as low a radiation dose as is reasonably achievable. The main purpose of this research is to develop a framework to monitor radiation dose and image quality in a mixed breast screening and diagnostic imaging environment using an automated tracking system. This study presents a module of this framework, consisting of a computerized system to measure the image quality of the American College of Radiology mammography accreditation phantom. The methods developed combine correlation approaches, matched filters, and data mining techniques. These methods have been used to analyze radiological images of the accreditation phantom. The classification of structures of interest is based upon reports produced by four trained readers. As previously reported, human observers demonstrate great variation in their analysis due to the subjectivity of human visual inspection. The software tool was trained with three sets of 60 phantom images in order to generate decision trees using the software WEKA (Waikato Environment for Knowledge Analysis). When tested with 240 images during the classification step, the tool correctly classified 88%, 99%, and 98%, of fibers, speck groups and masses, respectively. The variation between the computer classification and human reading was comparable to the variation between human readers. This computerized system not only automates the quality control procedure in mammography, but also decreases the subjectivity in the expert evaluation of the phantom images.
USING THE HERMITE POLYNOMIALS IN RADIOLOGICAL MONITORING NETWORKS.
Benito, G; Sáez, J C; Blázquez, J B; Quiñones, J
2018-03-15
The most interesting events in Radiological Monitoring Network correspond to higher values of H*(10). The higher doses cause skewness in the probability density function (PDF) of the records, which there are not Gaussian anymore. Within this work the probability of having a dose >2 standard deviations is proposed as surveillance of higher doses. Such probability is estimated by using the Hermite polynomials for reconstructing the PDF. The result is that the probability is ~6 ± 1%, much >2.5% corresponding to Gaussian PDFs, which may be of interest in the design of alarm level for higher doses.
Dose measurements in intraoral radiography using thermoluminescent dosimeters
NASA Astrophysics Data System (ADS)
Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.
2015-01-01
The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.
Vassileva, J; Dimov, A; Slavchev, A; Karadjov, A
2005-01-01
Results from a Bulgarian patient dose survey in diagnostic radiology are presented. Reference levels for entrance surface dose (ESD) were 0.9 mGy for chest radiography (PA), 30 mGy for lumbar spine (Lat), 10 mGy for pelvis, 5 mGy for skull (AP), 3 mGy for skull (Lat) and 13 mGy for mammography. Quality control (QC) programmes were proposed for various areas of diagnostic radiology. Film processing QC warranted special attention. Proposed QC programmes included parameters to be tested, level of expertise needed and two action levels: remedial and suspension. Programmes were tested under clinical conditions to assess initial results and draw conclusions for further QC system development. On the basis of international experience, measurement protocols were developed for all parameters tested. QC equipment was provided as part of the PHARE project. A future problem for QC programme implementation may be the small number of medical physics experts in diagnostic radiology.
Radioactive Waste Management Complex low-level waste radiological performance assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maheras, S.J.; Rood, A.S.; Magnuson, S.O.
This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsitemore » receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected.« less
2008-06-17
dosimeters . .............................................................................................. 117 Figure 4-2. Flow chart illustrating...alanine, various sugars, quartz in rocks and sulfates, as EPR dosimeters [15]. Alternatively, radiation-induced EPR signals have been detected using...the medical response to radiological accidents, as a method for estimating radiation dose without the use of physical dosimeters and using exposed
Bassinet, Céline; Huet, Christelle; Baumann, Marion; Etard, Cécile; Réhel, Jean-Luc; Boisserie, Gilbert; Debroas, Jacques; Aubert, Bernard; Clairand, Isabelle
2013-04-01
As MOSFET (Metal Oxide Semiconductor Field Effect Transistor) detectors allow dose measurements in real time, the interest in these dosimeters is growing. The aim of this study was to investigate the dosimetric properties of commercially available TN-502RD-H MOSFET silicon detectors (Best Medical Canada, Ottawa, Canada) in order to use them for in vivo dosimetry in interventional radiology and for dose reconstruction in case of overexposure. Reproducibility of the measurements, dose rate dependence, and dose response of the MOSFET detectors have been studied with a Co source. Influence of the dose rate, frequency, and pulse duration on MOSFET responses has also been studied in pulsed x-ray fields. Finally, in order to validate the integrated dose given by MOSFET detectors, MOSFETs and TLDs (LiF:Mg,Cu,P) were fixed on an Alderson-Rando phantom in the conditions of an interventional neuroradiology procedure, and their responses have been compared. The results of this study show the suitability of MOSFET detectors for in vivo dosimetry in interventional radiology and for dose reconstruction in case of accident, provided a well-corrected energy dependence, a pulse duration equal to or higher than 10 ms, and an optimized contact between the detector and the skin of the patient are achieved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zwahlen, Daniel R.; Department of Radiation Oncology, University Hospital Zurich, Zurich; Ruben, Jeremy D.
2009-06-01
Purpose: To estimate and compare intensity-modulated radiotherapy (IMRT) with three-dimensional conformal radiotherapy (3DCRT) in terms of second cancer risk (SCR) for postoperative treatment of endometrial and cervical cancer. Methods and Materials: To estimate SCR, the organ equivalent dose concept with a linear-exponential, a plateau, and a linear dose-response model was applied to dose distributions, calculated in a planning computed tomography scan of a 68-year-old woman. Three plans were computed: four-field 18-MV 3DCRT and nine-field IMRT with 6- and 18-MV photons. SCR was estimated as a function of target dose (50.4 Gy/28 fractions) in organs of interest according to the Internationalmore » Commission on Radiological Protection Results: Cumulative SCR relative to 3DCRT was +6% (3% for a plateau model, -4% for a linear model) for 6-MV IMRT and +26% (25%, 4%) for the 18-MV IMRT plan. For an organ within the primary beam, SCR was +12% (0%, -12%) for 6-MV and +5% (-2%, -7%) for 18-MV IMRT. 18-MV IMRT increased SCR 6-7 times for organs away from the primary beam relative to 3DCRT and 6-MV IMRT. Skin SCR increased by 22-37% for 6-MV and 50-69% for 18-MV IMRT inasmuch as a larger volume of skin was exposed. Conclusion: Cancer risk after IMRT for cervical and endometrial cancer is dependent on treatment energy. 6-MV pelvic IMRT represents a safe alternative with respect to SCR relative to 3DCRT, independently of the dose-response model. 18-MV IMRT produces second neutrons that modestly increase the SCR.« less
The Effectiveness of Computer-Based Hypermedia Teaching Modules for Radiology Residents.
ERIC Educational Resources Information Center
Azevedo, Roger; And Others
This paper explains the rationale for utilizing computer-based, hypermedia tutorials for radiology education and presents the results of a field test of this educational technique. It discusses the development of the hypermedia tutorials at Montreal General Hospital (Quebec, Canada) in 1991-92 and their use in the radiology residency program. The…
Leong, Sum; Mc Laughlin, Patrick; O'Connor, Owen J; O'Flynn, Siun; Maher, Michael M
2012-03-01
Integrating radiation protection (RP) education in the undergraduate medical curriculum is gaining importance and is mandatory in certain jurisdictions. An e-learning module for RP was developed at the authors' medical school and was integrated into year 4 of the 5-year undergraduate medical program. The aim of this study was to investigate its impact on RP knowledge, student preferences for various teaching methods, self-assessment of RP knowledge, and perceptions of career prospects in radiology. Likert-type 5-point scale evaluations and general comments about the RP module and various methods of teaching were also obtained. An e-learning module in RP was designed and presented to year 4 medical undergraduates. All students were required to complete premodule and postmodule questionnaires. Eighty-nine percent (n = 113) and 99% (n = 126) of the 127 medical students successfully completed and returned the premodule and postmodule questionnaires, respectively. After the e-learning module, students' postmodule RP knowledge had improved significantly. Analysis of postmodule RP knowledge suggested that a favorable self-assessment of knowledge of RP, perception of career prospects in radiology, and completion of the e-learning module with an increased number of sessions were factors predictive of improved RP knowledge. Students expressed a preference for didactic lectures and clinical attachment for instruction in RP over e-learning. The development of an e-learning module in RP is feasible and results in improved knowledge of RP among medical undergraduates. Combining e-learning and more traditional educational programs such as a clinical radiology rotation is likely to improve student experience. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Relative radiological risks derived from different TENORM wastes in Malaysia.
Ismail, B; Teng, I L; Muhammad Samudi, Y
2011-11-01
In Malaysia technologically enhanced naturally occurring radioactive materials (TENORM) wastes are mainly the product of the oil and gas industry and mineral processing. Among these TENORM wastes are tin tailing, tin slag, gypsum and oil sludge. Mineral processing and oil and gas industries produce large volume of TENORM wastes that has become a radiological concern to the authorities. A study was carried out to assess the radiological risk related to workers working at these disposal sites and landfills as well as to the members of the public should these areas be developed for future land use. Radiological risk was assessed based on the magnitude of radiation hazard, effective dose rates and excess cancer risks. Effective dose rates and excess cancer risks were estimated using RESRAD 6.4 computer code. All data on the activity concentrations of NORM in wastes and sludges used in this study were obtained from the Atomic Energy Licensing Board, Malaysia, and they were collected over a period of between 5 and 10 y. Results obtained showed that there was a wide range in the total activity concentrations (TAC) of nuclides in the TENORM wastes. With the exception of tin slag and tin tailing-based TENORM wastes, all other TENORM wastes have TAC values comparable to that of Malaysia's soil. Occupational Effective Dose Rates estimated in all landfill areas were lower than the 20 mSv y(-1) permissible dose limit. The average Excess Cancer Risk Coefficient was estimated to be 2.77×10(-3) risk per mSv. The effective dose rates for residents living on gypsum and oil sludge-based TENORM wastes landfills were estimated to be lower than the permissible dose limit for members of the public, and was also comparable to that of the average Malaysia's ordinary soils. The average excess cancer risk coefficient was estimated to be 3.19×10(-3) risk per mSv. Results obtained suggest that gypsum and oil sludge-based TENORM wastes should be exempted from any radiological regulatory control and should be considered radiologically safe for future land use.
Study of natural radioactivity in Mansehra granite, Pakistan: environmental concerns.
Qureshi, Aziz Ahmed; Jadoon, Ishtiaq Ahmed Khan; Wajid, Ali Abbas; Attique, Ahsan; Masood, Adil; Anees, Muhammad; Manzoor, Shahid; Waheed, Abdul; Tubassam, Aneela
2014-03-01
A part of Mansehra Granite was selected for the assessment of radiological hazards. The average activity concentrations of (226)Ra, (232)Th and (40)K were found to be 27.32, 50.07 and 953.10 Bq kg(-1), respectively. These values are in the median range when compared with the granites around the world. Radiological hazard indices and annual effective doses were estimated. All of these indices were found to be within the criterion limits except outdoor external dose (82.38 nGy h(-1)) and indoor external dose (156.04 nGy h(-1)), which are higher than the world's average background levels of 51 and 55 nGy h(-1), respectively. These values correspond to an average annual effective dose of 0.867 mSv y(-1), which is less than the criterion limit of 1 mSv y(-1) (ICRP-103). Some localities in the Mansehra city have annual effective dose higher than the limit of 1 mSv y(-1). Overall, the Mansehra Granite does not pose any significant radiological health hazard in the outdoor or indoor.
Radioactivity concentrations in soils in the Qingdao area, China.
Qu, Limei; Yao, De; Cong, Pifu; Xia, Ning
2008-10-01
The specific activity concentrations of radionuclides (238)U, (232)Th, and (40)K of 2300 sampling points in the Qingdao area were measured by an FD-3022 gamma-ray spectrometer. The radioactivity concentrations of (238)U, (232)Th, and (40)K ranged from 3.3 to 185.3, from 6.9 to 157.2, and from 115.8 to 7834.4 Bq kg(-1), respectively. The air-absorbed dose at 1 meter above ground, effective annual dose, external hazard index, and radium equivalent activity were also calculated to systematically evaluate the radiological hazards of the natural radioactivity in Qingdao. The air-absorbed dose, effective annual dose, external hazard index, and radium equivalent activity in the study area were 98.6 nGy h(-1), 0.12 mSv, 0.56, 197 Bq kg(-1), respectively. Compared with the worldwide value, the air-absorbed dose is slightly high, but the other factors are all lower than the recommended value. The natural external exposure will not pose significant radiological threat to the population. In conclusion, the Qingdao area is safe with regard to the radiological level and suitable for living.
EMP Attachment 3 DOE-SC PNNL Site Dose Assessment Guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.
2011-12-21
This Dose Assessment Guidance (DAG) describes methods to use to determine the Maximally-Exposed Individual (MEI) location and to estimate dose impact to that individual under the U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest National Laboratory (PNNL) Site Environmental Monitoring Plan (EMP). This guidance applies to public dose from radioactive material releases to the air from PNNL Site operations. This document is an attachment to the Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP) and describes dose assessment guidance for radiological air emissions. The impact of radiological air emissions from the U.S. Department of Energy Office ofmore » Science (DOE-SC) PNNL Site is indicated by dose estimates to a maximally exposed member of the public, referred to as the maximally exposed individual (MEI). Reporting requirements associated with dose to members of the public from radiological air emissions are in 40 CFR Part 61.94, WAC 246-247-080, and DOE Order 458.1. The DOE Order and state standards for dose from radioactive air emissions are consistent with U.S. Environmental Protection Agency (EPA) dose standards in 40 CFR 61.92 (i.e., 10 mrem/yr to a MEI). Despite the fact that the current Contract Requirements Document (CRD) for the DOE-SC PNNL Site operations does not include the requirement to meet DOE CRD 458.1, paragraph 2.b, public dose limits, the DOE dose limits would be met when EPA limits are met.« less
Monte Carlo calculations for reporting patient organ doses from interventional radiology
NASA Astrophysics Data System (ADS)
Huo, Wanli; Feng, Mang; Pi, Yifei; Chen, Zhi; Gao, Yiming; Xu, X. George
2017-09-01
This paper describes a project to generate organ dose data for the purposes of extending VirtualDose software from CT imaging to interventional radiology (IR) applications. A library of 23 mesh-based anthropometric patient phantoms were involved in Monte Carlo simulations for database calculations. Organ doses and effective doses of IR procedures with specific beam projection, filed of view (FOV) and beam quality for all parts of body were obtained. Comparing organ doses for different beam qualities, beam projections, patients' ages and patient's body mass indexes (BMIs) which generated by VirtualDose-IR, significant discrepancies were observed. For relatively long time exposure, IR doses depend on beam quality, beam direction and patient size. Therefore, VirtualDose-IR, which is based on the latest anatomically realistic patient phantoms, can generate accurate doses for IR treatment. It is suitable to apply this software in clinical IR dose management as an effective tool to estimate patient doses and optimize IR treatment plans.
Radiological Society of North America
... Courses Electronic Education Exhibits RSNA Journals RSNA/AAPM Physics Modules RadioGraphics ABR Diagnostic Radiology Core Exam Study ... Brain Tumor Classification System In 2016, the World Health Organization (WHO) released an update to its brain ...
National survey on dose data analysis in computed tomography.
Heilmaier, Christina; Treier, Reto; Merkle, Elmar Max; Alkhadi, Hatem; Weishaupt, Dominik; Schindera, Sebastian
2018-05-28
A nationwide survey was performed assessing current practice of dose data analysis in computed tomography (CT). All radiological departments in Switzerland were asked to participate in the on-line survey composed of 19 questions (16 multiple choice, 3 free text). It consisted of four sections: (1) general information on the department, (2) dose data analysis, (3) use of a dose management software (DMS) and (4) radiation protection activities. In total, 152 out of 241 Swiss radiological departments filled in the whole questionnaire (return rate, 63%). Seventy-nine per cent of the departments (n = 120/152) analyse dose data on a regular basis with considerable heterogeneity in the frequency (1-2 times per year, 45%, n = 54/120; every month, 35%, n = 42/120) and method of analysis. Manual analysis is carried out by 58% (n = 70/120) compared with 42% (n = 50/120) of departments using a DMS. Purchase of a DMS is planned by 43% (n = 30/70) of the departments with manual analysis. Real-time analysis of dose data is performed by 42% (n = 21/50) of the departments with a DMS; however, residents can access the DMS in clinical routine only in 20% (n = 10/50) of the departments. An interdisciplinary dose team, which among other things communicates dose data internally (63%, n = 76/120) and externally, is already implemented in 57% (n = 68/120) departments. Swiss radiological departments are committed to radiation safety. However, there is high heterogeneity among them regarding the frequency and method of dose data analysis as well as the use of DMS and radiation protection activities. • Swiss radiological departments are committed to and interest in radiation safety as proven by a 63% return rate of the survey. • Seventy-nine per cent of departments analyse dose data on a regular basis with differences in the frequency and method of analysis: 42% use a dose management software, while 58% currently perform manual dose data analysis. Of the latter, 43% plan to buy a dose management software. • Currently, only 25% of the departments add radiation exposure data to the final CT report.
Park, Hye-Suk; Kim, Ye-Seul; Park, Ok-Seob; Kim, Sang-Tae; Jeon, Chang-Woo; Kim, Hee-Joung
2014-04-01
The purpose of this study was to investigate the effect of various technical parameters for dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE). For tube voltages ranging from 40 to 90 kV in 10 kV increments at the focus-to-detector distance (FDD) of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at same effective dose. The eDQE was considerably higher without the use of the grid on equivalent effective dose. This indicates that the reduction of scatter radiation did not compensate for the loss of absorbed effective photons in the grid. The eDQE increased with increasing FDD because of the greater effective modulation transfer function (eMTF) with lower focal spot blurring. However, most of the major hospitals in Korea employed a short FDD of 100 cm with the grid. The entrance surface air kerma values for the hospitals of this survey exceeded the Korean reference level of 100 μGy. The different reference levels might be appropriate for the same examination conducted on children of different ages. Also, it is necessary to refine the technical parameters to perform pediatric chest examinations.
Comprehensive analysis of a Radiology Operations Management computer system.
Arenson, R L; London, J W
1979-11-01
The Radiology Operations Management computer system at the Hospital of the University of Pennsylvania is discussed. The scheduling and file room modules are based on the system at Massachusetts General Hospital. Patient delays are indicated by the patient tracking module. A reporting module allows CRT/keyboard entry by transcriptionists, entry of standard reports by radiologists using bar code labels, and entry by radiologists using a specialty designed diagnostic reporting terminal. Time-flow analyses demonstrate a significant improvement in scheduling, patient waiting, retrieval of radiographs, and report delivery. Recovery of previously lost billing contributes to the proved cost effectiveness of this system.
Dane, Bari; Doshi, Ankur; Gfytopoulos, Soterios; Bhattacharji, Priya; Recht, Michael; Moore, William
2018-05-01
Radiology-pathology correlation is time-consuming and is not feasible in most clinical settings, with the notable exception of breast imaging. The purpose of this study was to determine if an automated radiology-pathology report pairing system could accurately match radiology and pathology reports, thus creating a feedback loop allowing for more frequent and timely radiology-pathology correlation. An experienced radiologist created a matching matrix of radiology and pathology reports. These matching rules were then exported to a novel comprehensive radiology-pathology module. All distinct radiology-pathology pairings at our institution from January 1, 2016 to July 1, 2016 were included (n = 8999). The appropriateness of each radiology-pathology report pairing was scored as either "correlative" or "non-correlative." Pathology reports relating to anatomy imaged in the specific imaging study were deemed correlative, whereas pathology reports describing anatomy not imaged with the particular study were denoted non-correlative. Overall, there was 88.3% correlation (accuracy) of the radiology and pathology reports (n = 8999). Subset analysis demonstrated that computed tomography (CT) abdomen/pelvis, CT head/neck/face, CT chest, musculoskeletal CT (excluding spine), mammography, magnetic resonance imaging (MRI) abdomen/pelvis, MRI brain, musculoskeletal MRI (excluding spine), breast MRI, positron emission tomography (PET), breast ultrasound, and head/neck ultrasound all demonstrated greater than 91% correlation. When further stratified by imaging modality, CT, MRI, mammography, and PET demonstrated excellent correlation (greater than 96.3%). Ultrasound and non-PET nuclear medicine studies demonstrated poorer correlation (80%). There is excellent correlation of radiology imaging reports and appropriate pathology reports when matched by organ system. Rapid, appropriate radiology-pathology report pairings provide an excellent opportunity to close feedback loop to the interpreting radiologist. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Almén, Anja; Båth, Magnus
2016-06-01
The overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined. The outset of the optimisation process is four stages: providing equipment, establishing methodology, performing examinations and ensuring quality. The optimisation process comprises a series of activities and actions at these stages. The current system of diagnostic reference levels is an activity in the last stage, ensuring quality. The system becomes a reactive activity only to a certain extent engaging the core activity in the radiology department, performing examinations. Three reference dose levels-possible, expected and established-were assigned to the three stages in the optimisation process, excluding ensuring quality. A reasonably achievable dose range is also derived, indicating an acceptable deviation from the established dose level. A reasonable radiation dose for a single patient is within this range. The suggested framework for managing radiation dose should be regarded as one part of the optimisation process. The optimisation process constitutes a variety of complementary activities, where managing radiation dose is only one part. This emphasises the need to take a holistic approach integrating the optimisation process in different clinical activities. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
The geomagnetically trapped radiation environment: A radiological point of view
NASA Technical Reports Server (NTRS)
Holly, F. E.
1972-01-01
The regions of naturally occurring, geomagnetically trapped radiation are briefly reviewed in terms of physical parameters such as; particle types, fluxes, spectrums, and spatial distributions. The major emphasis is placed upon a description of this environment in terms of the radiobiologically relevant parameters of absorbed dose and dose-rate and a discussion of the radiological implications in terms of the possible impact on space vehicle design and mission planning.
Belfi, Lily M; Bartolotta, Roger J; Giambrone, Ashley E; Davi, Caryn; Min, Robert J
2015-06-01
Among methods of "blended learning" (ie, combining online modules with in-class instruction), the "flipped classroom" involves student preclass review of material while reserving class time for interactive knowledge application. We integrated blended learning methodology in a "flipped" introductory clerkship in radiology, and assessed the impact of this approach on the student educational experience (performance and perception). In preparation for the "flipped clerkship," radiology faculty and residents created e-learning modules that were uploaded to an open-source website. The clerkship's 101 rising third-year medical students were exposed to different teaching methods during the course, such as blended learning, traditional lecture learning, and independent learning. Students completed precourse and postcourse knowledge assessments and surveys. Student knowledge improved overall as a result of taking the course. Blended learning achieved greater pretest to post-test improvement of high statistical significance (P value, .0060) compared to lecture learning alone. Blended learning also achieved greater pretest to post-test improvement of borderline statistical significance (P value, .0855) in comparison to independent learning alone. The difference in effectiveness of independent learning versus lecture learning was not statistically significant (P value, .2730). Student perceptions of the online modules used in blended learning portions of the course were very positive. They specifically enjoyed the self-paced interactivity and the ability to return to the modules in the future. Blended learning can be successfully applied to the introductory clerkship in radiology. This teaching method offers educators an innovative and efficient approach to medical student education in radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J; Keller, Brian M; Presutti, Joseph; Sharpe, Michael
2006-05-21
Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 microm are generated for field size below 2 x 2 cm2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam.
NASA Astrophysics Data System (ADS)
O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J.; Keller, Brian M.; Presutti, Joseph; Sharpe, Michael
2006-05-01
Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 µm are generated for field size below 2 × 2 cm2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam.
O'Connor, U; Gallagher, A; Malone, L; O'Reilly, G
2013-02-01
Endoscopic retrograde cholangiopancreatography (ERCP) is a common procedure that combines the use of X-ray fluoroscopy and endoscopy for examination of the bile duct. Published data on ERCP doses are limited, including staff eye dose from ERCP. Occupational eye doses are of particular interest now as the International Commission on Radiological Protection (ICRP) has recommended a reduction in the dose limit to the lens of the eye. The aim of this study was to measure occupational eye doses obtained from ERCP procedures. A new eye lens dosemeter (EYE-D(™), Radcard, Krakow, Poland) was used to measure the ERCP eye dose, H(p)(3), at two endoscopy departments in Ireland. A review of radiation protection practice at the two facilities was also carried out. The mean equivalent dose to the lens of the eye of a gastroenterologist is 0.01 mSv per ERCP procedure with an undercouch X-ray tube and 0.09 mSv per ERCP procedure with an overcouch X-ray tube. Staff eye dose normalised to patient kerma area product is also presented. Staff eye doses in ERCP have the potential to exceed the revised ICRP limit of 20 mSv per annum when an overcouch X-ray tube is used. The EYE-D dosemeter was found to be a convenient method for measuring lens dose. Eye doses in areas outside of radiology departments should be kept under review, particularly in light of the new ICRP eye dose limit. Occupational eye lens doses from ERCP procedures have been established using a new commercially available dedicated H(p)(3) dosemeter.
Safari, Mohammad Javad; Wong, Jeannie Hsiu Ding; Jong, Wei Loong; Thorpe, Nathan; Cutajar, Dean; Rosenfeld, Anatoly; Ng, Kwan Hoong
2017-03-01
The purpose of this study was to investigate the effects of routine exposure parameters on patient's dose during neuro-interventional radiology procedures. We scrutinized the routine radiological exposure parameters during 58 clinical neuro-interventional procedures such as, exposure direction, magnification, frame rate, and distance between image receptor to patient's body and evaluate their effects on patient's dose using an anthropomorphic phantom. Radiation dose received by the occipital region, ears and eyes of the phantom were measured using MOSkin detectors. DSA imaging technique is a major contributor to patient's dose (80.9%) even though they are used sparingly (5.3% of total frame number). The occipital region of the brain received high dose largely from the frontal tube constantly placed under couch (73.7% of the total KAP). When rotating the frontal tube away from under the couch, the radiation dose to the occipital reduced by 40%. The use of magnification modes could increase radiation dose by 94%. Changing the image receptor to the phantom surface distance from 10 to 40cm doubled the radiation dose received by the patient's skin at the occipital region. Our findings provided important insights into the contribution of selected fluoroscopic exposure parameters and their impact on patient's dose during neuro-interventional radiology procedures. This study showed that the DSA imaging technique contributed to the highest patient's dose and judicial use of exposure parameters might assist interventional radiologists in effective skin and eye lens dose reduction for patients undergoing neuro-interventional procedures. Copyright © 2017 Associazione Italiana di Fisica Medica. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Detilleux, Michel; Centner, Baudouin
The paper describes different methodologies and tools developed in-house by Tractebel Engineering to facilitate the engineering works to be carried out especially in the frame of decommissioning projects. Three examples of tools with their corresponding results are presented: - The LLWAA-DECOM code, a software developed for the radiological characterization of contaminated systems and equipment. The code constitutes a specific module of more general software that was originally developed to characterize radioactive waste streams in order to be able to declare the radiological inventory of critical nuclides, in particular difficult-to-measure radionuclides, to the Authorities. In the case of LLWAA-DECOM, deposited activitiesmore » inside contaminated equipment (piping, tanks, heat exchangers...) and scaling factors between nuclides, at any given time of the decommissioning time schedule, are calculated on the basis of physical characteristics of the systems and of operational parameters of the nuclear power plant. This methodology was applied to assess decommissioning costs of Belgian NPPs, to characterize the primary system of Trino NPP in Italy, to characterize the equipment of miscellaneous circuits of Ignalina NPP and of Kozloduy unit 1 and, to calculate remaining dose rates around equipment in the frame of the preparation of decommissioning activities; - The VISIMODELLER tool, a user friendly CAD interface developed to ease the introduction of lay-out areas in a software named VISIPLAN. VISIPLAN is a 3D dose rate assessment tool for ALARA work planning, developed by the Belgian Nuclear Research Centre SCK.CEN. Both softwares were used for projects such as the steam generators replacements in Belgian NPPs or the preparation of the decommissioning of units 1 and 2 of Kozloduy NPP; - The DBS software, a software developed to manage the different kinds of activities that are part of the general time schedule of a decommissioning project. For each activity, when relevant, algorithms allow to estimate, on the basis of local inputs, radiological exposures of the operators (collective and individual doses), production of primary, secondary and tertiary waste and their characterization, production of conditioned waste, release of effluents,... and enable the calculation and the presentation (histograms) of the global results for all activities together. An example of application in the frame of the Ignalina decommissioning project is given. (authors)« less
Radioactive Waste Management Complex performance assessment: Draft
DOE Office of Scientific and Technical Information (OSTI.GOV)
Case, M.J.; Maheras, S.J.; McKenzie-Carter, M.A.
1990-06-01
A radiological performance assessment of the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory was conducted to demonstrate compliance with appropriate radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the general public. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the general public via air, ground water, and food chain pathways. Projections of doses were made for both offsite receptors and individuals intruding onto the site after closure. In addition, uncertainty analyses were performed. Resultsmore » of calculations made using nominal data indicate that the radiological doses will be below appropriate radiological criteria throughout operations and after closure of the facility. Recommendations were made for future performance assessment calculations.« less
Huet, C; Lemosquet, A; Clairand, I; Rioual, J B; Franck, D; de Carlan, L; Aubineau-Lanièce, I; Bottollier-Depois, J F
2009-01-01
Estimating the dose distribution in a victim's body is a relevant indicator in assessing biological damage from exposure in the event of a radiological accident caused by an external source. This dose distribution can be assessed by physical dosimetric reconstruction methods. Physical dosimetric reconstruction can be achieved using experimental or numerical techniques. This article presents the laboratory-developed SESAME--Simulation of External Source Accident with MEdical images--tool specific to dosimetric reconstruction of radiological accidents through numerical simulations which combine voxel geometry and the radiation-material interaction MCNP(X) Monte Carlo computer code. The experimental validation of the tool using a photon field and its application to a radiological accident in Chile in December 2005 are also described.
New Nuclear Emergency Prognosis system in Korea
NASA Astrophysics Data System (ADS)
Lee, Hyun-Ha; Jeong, Seung-Young; Park, Sang-Hyun; Lee, Kwan-Hee
2016-04-01
This paper reviews the status of assessment and prognosis system for nuclear emergency response in Korea, especially atmospheric dispersion model. The Korea Institute of Nuclear Safety (KINS) performs the regulation and radiological emergency preparedness of the nuclear facilities and radiation utilizations. Also, KINS has set up the "Radiological Emergency Technical Advisory Plan" and the associated procedures such as an emergency response manual in consideration of the IAEA Safety Standards GS-R-2, GS-G-2.0, and GS-G-2.1. The Radiological Emergency Technical Advisory Center (RETAC) organized in an emergency situation provides the technical advice on radiological emergency response. The "Atomic Computerized Technical Advisory System for nuclear emergency" (AtomCARE) has been developed to implement assessment and prognosis by RETAC. KINS developed Accident Dose Assessment and Monitoring (ADAMO) system in 2015 to reflect the lessons learned from Fukushima accident. It incorporates (1) the dose assessment on the entire Korean peninsula, Asia region, and global region, (2) multi-units accident assessment (3) applying new methodology of dose rate assessment and the source term estimation with inverse modeling, (4) dose assessment and monitoring with the environmental measurements result. The ADAMO is the renovated version of current FADAS of AtomCARE. The ADAMO increases the accuracy of the radioactive material dispersion with applying the LDAPS(Local Data Assimilation Prediction System, Spatial resolution: 1.5 km) and RDAPS(Regional Data Assimilation Prediction System, Spatial resolution: 12km) of weather prediction data, and performing the data assimilation of automatic weather system (AWS) data from Korea Meteorological Administration (KMA) and data from the weather observation tower at NPP site. The prediction model of the radiological material dispersion is based on the set of the Lagrangian Particle model and Lagrangian Puff model. The dose estimation methodology incorporate the dose assessment methods of IAEA, WHO, and USNRC. The dose assessment result will express on the GIS (GIS (Geographic Information System) to provide to the local- governments and the central government. Acknowledgements This research has been supported by the Nuclear Safety and Security Commission [Reference No.1305020-0315-SB110
Koontz, Nicholas A; Gunderman, Richard B
2012-04-01
This study assesses the effect on medical student understanding of a new radiobiology and radiation safety module in a fourth-year radiology clerkship. A dedicated radiobiology and radiation safety module was incorporated into the fourth-year medical school radiology clerkship at our institution. Student understanding of the material was assessed via pretest and posttest. Statistical analysis was performed to assess significance of changes in student performance. In addition, we surveyed student perceptions of the importance of this material in medical education and practice. Monthly pretest mean scores ranged from 47.8% to 55.6%, with an average monthly pretest score of 50.3%. Monthly posttest mean scores ranged from 77.3% to 91.2%, with an average monthly posttest score of 83.9%. The improvement in exam scores after the educational intervention was statistically significant (all P < .01). The introduction of a new educational module can significantly improve medical student understanding of radiobiology and radiation safety. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
Efficacy of radiation safety glasses in interventional radiology.
van Rooijen, Bart D; de Haan, Michiel W; Das, Marco; Arnoldussen, Carsten W K P; de Graaf, R; van Zwam, Wim H; Backes, Walter H; Jeukens, Cécile R L P N
2014-10-01
This study was designed to evaluate the reduction of the eye lens dose when wearing protective eyewear in interventional radiology and to identify conditions that optimize the efficacy of radiation safety glasses. The dose reduction provided by different models of radiation safety glasses was measured on an anthropomorphic phantom head. The influence of the orientation of the phantom head on the dose reduction was studied in detail. The dose reduction in interventional radiological practice was assessed by dose measurements on radiologists wearing either leaded or no glasses or using a ceiling suspended screen. The different models of radiation safety glasses provided a dose reduction in the range of a factor of 7.9-10.0 for frontal exposure of the phantom. The dose reduction was strongly reduced when the head is turned to the side relative to the irradiated volume. The eye closest to the tube was better protected due to side shielding and eyewear curvature. In clinical practice, the mean dose reduction was a factor of 2.1. Using a ceiling suspended lead glass shield resulted in a mean dose reduction of a factor of 5.7. The efficacy of radiation protection glasses depends on the orientation of the operator's head relative to the irradiated volume. Glasses can offer good protection to the eye under clinically relevant conditions. However, the performance in clinical practice in our study was lower than expected. This is likely related to nonoptimized room geometry and training of the staff as well as measurement methodology.
2006-01-01
This report compiles the various numerical protection level values published by the International Commission on Radiological Protection (ICRP) since its 1990 Recommendations (Publication 60). Several terms are used to denominate the protection levels: individual dose limit, 'maximum' individual dose, dose constraint, exemption level, exclusion level, action level, or intervention level. The reasons provided by the Commission for selecting the associated numerical values is quoted as far as available. In some cases the rationale is not totally explicit in the original ICRP report concerned; in such cases the Task Group that prepared the present report have proposed their own interpretation. Originally, this report was prepared by a Task Group at CEPN, a French research and development center, in behalf of IRSN, a French public expert body engaged in radiological protection and nuclear safety. It is published here with kind permission by CEPN and IRSN.
Weiss, W; Larsson, C-M; McKenney, C; Minon, J-P; Mobbs, S; Schneider, T; Umeki, H; Hilden, W; Pescatore, C; Vesterlind, M
2013-06-01
This report updates and consolidates previous recommendations of the International Commission on Radiological Protection (ICRP) related to solid waste disposal (ICRP, 1985, 1997b, 1998). The recommendations given apply specifically to geological disposal of long-lived solid radioactive waste. The report explains how the ICRP system of radiological protection described in Publication 103 (ICRP, 2007) can be applied in the context of the geological disposal of long-lived solid radioactive waste. Although the report is written as a standalone document, previous ICRP recommendations not dealt with in depth in the report are still valid. The 2007 ICRP system of radiological protection evolves from the previous process-based protection approach relying on the distinction between practices and interventions by moving to an approach based on the distinction between three types of exposure situation: planned, emergency and existing. The Recommendations maintains the Commission's three fundamental principles of radiological protection namely: justification, optimisation of protection and the application of dose limits. They also maintain the current individual dose limits for effective dose and equivalent dose from all regulated sources in planned exposure situations. They re-enforce the principle of optimisation of radiological protection, which applies in a similar way to all exposure situations, subject to restrictions on individual doses: constraints for planned exposure situations, and reference levels for emergency and existing exposure situations. The Recommendations also include an approach for developing a framework to demonstrate radiological protection of the environment. This report describes the different stages in the life time of a geological disposal facility, and addresses the application of relevant radiological protection principles for each stage depending on the various exposure situations that can be encountered. In particular, the crucial factor that influences the application of the protection system over the different phases in the life time of a disposal facility is the level of oversight or 'watchful care' that is present. The level of oversight affects the capability to control the source, i.e. the waste and the repository, and to avoid or reduce potential exposures. Three main time frames are considered: time of direct oversight, when the disposal facility is being implemented and is under active supervision; time of indirect oversight, when the disposal facility is sealed and oversight is being exercised by regulators or special administrative bodies or society at large to provide additional assurance on behalf of society; and time of no oversight, when oversight is no longer exercised in case memory of the disposal facility is lost. Copyright © 2013. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kraus, Terrence D.
2017-04-01
This report specifies the electronic file format that was agreed upon to be used as the file format for normalized radiological data produced by the software tool developed under this TI project. The NA-84 Technology Integration (TI) Program project (SNL17-CM-635, Normalizing Radiological Data for Analysis and Integration into Models) investigators held a teleconference on December 7, 2017 to discuss the tasks to be completed under the TI program project. During this teleconference, the TI project investigators determined that the comma-separated values (CSV) file format is the most suitable file format for the normalized radiological data that will be outputted frommore » the normalizing tool developed under this TI project. The CSV file format was selected because it provides the requisite flexibility to manage different types of radiological data (i.e., activity concentration, exposure rate, dose rate) from other sources [e.g., Radiological Assessment and Monitoring System (RAMS), Aerial Measuring System (AMS), Monitoring and Sampling). The CSV file format also is suitable for the file format of the normalized radiological data because this normalized data can then be ingested by other software [e.g., RAMS, Visual Sampling Plan (VSP)] used by the NA-84’s Consequence Management Program.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fulton, John; Gallagher, Linda K.; Whitener, Dustin
The Turbo FRMAC (TF) software automates the calculations described in volumes 1-3 of "The Federal Manual for Assessing Environmental Data During a Radiological Emergency" (2010 version). This software automates the process of assessing radiological data during a Federal Radiological Emergency. The manual upon which the software is based is unclassified and freely available on the Internet. TF takes values generated by field samples or computer dispersion models and assesses the data in a way which is meaningful to a decision maker at a radiological emergency; such as, do radiation values exceed city, state, or federal limits; should the crops bemore » destroyed or can they be utilized; do residents need to be evacuated, sheltered in place, or should another action taken. The software also uses formulas generated by the EPA, FDA, and other federal agencies to generate field observable values specific to the radiological event that can be used to determine where regulatory limit values are exceeded. In addition to these calculations, TF calculates values which indicate how long an emergency worker can work in the contaminated area during a radiological emergency, the dose received from drinking contaminated water or milk, the dose from eating contaminated food, the does expected down or upwind of a given field sample, along with a significant number of other similar radiological health values.« less
Natural radiation and its hazard in copper ore mines in Poland
NASA Astrophysics Data System (ADS)
Chau, Nguyen; Jodłowski, Paweł; Kalita, Stefan; Olko, Paweł; Chruściel, Edward; Maksymowicz, Adam; Waligórski, Michał; Bilski, Paweł; Budzanowski, Maciej
2008-06-01
The doses of gamma radiation, concentrations of radium isotopes in water and sediments, radon concentration and concentration of alpha potential energy of radon decay products in the copper ore mine and in the mining region in the vicinity of Lubin town in Poland are presented. These data served as a basis for the assessment of radiological hazard to the mine workers and general public. The results of this assessment indicate that radiological hazard in the region does not differ substantially from typical values associated with natural radiation background. The calculated average annual effective dose for copper miners is 1.48 mSv. In general, copper ore mines can be regarded as radiologically safe workplaces.
Radiological NESHAP ANNUAL REPORT CY 2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evelo, Stacie
2017-06-01
This report provides a summary of the radionuclide releases from the United States (U.S.) Department of Energy (DOE) National Nuclear Security Administration facilities at Sandia National Laboratories, New Mexico (SNL/NM) during Calendar Year (CY) 2016, including the data, calculations, and supporting documentation for demonstrating compliance with 40 Code of Federal Regulation (CFR) 61, Subpart H--NATIONAL EMISSION STANDARDS FOR EMISSIONS OF RADIONUCLIDES OTHER THAN RADON FROM DEPARTMENT OF ENERGY FACILITIES (Radiological NESHAP). A description is given of the sources and their contributions to the overall dose assessment. In addition, the maximally exposed individual (MEI) radiological dose calculation and the population dosemore » to local and regional residents are discussed.« less
RCT: Module 2.11, Radiological Work Coverage, Course 8777
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hillmer, Kurt T.
2017-07-20
Radiological work is usually approved and controlled by radiation protection personnel by using administrative and procedural controls, such as radiological work permits (RWPs). In addition, some jobs will require working in, or will have the potential for creating, very high radiation, contamination, or airborne radioactivity areas. Radiological control technicians (RCTs) providing job coverage have an integral role in controlling radiological hazards. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.
TH-E-209-00: Radiation Dose Monitoring and Protocol Management
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, B.
2016-06-15
Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less
TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacDougall, R.
Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less
Preliminary analyses of space radiation protection for lunar base surface systems
NASA Technical Reports Server (NTRS)
Nealy, John E.; Wilson, John W.; Townsend, Lawrence W.
1989-01-01
Radiation shielding analyses are performed for candidate lunar base habitation modules. The study primarily addresses potential hazards due to contributions from the galactic cosmic rays. The NASA Langley Research Center's high energy nucleon and heavy ion transport codes are used to compute propagation of radiation through conventional and regolith shield materials. Computed values of linear energy transfer are converted to biological dose-equivalent using quality factors established by the International Commision of Radiological Protection. Special fluxes of heavy charged particles and corresponding dosimetric quantities are computed for a series of thicknesses in various shield media and are used as an input data base for algorithms pertaining to specific shielded geometries. Dosimetric results are presented as isodose contour maps of shielded configuration interiors. The dose predictions indicate that shielding requirements are substantial, and an abbreviated uncertainty analysis shows that better definition of the space radiation environment as well as improvement in nuclear interaction cross-section data can greatly increase the accuracy of shield requirement predictions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rehman, Jalil ur, E-mail: jalil_khanphy@yahoo.com; Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX; Tailor, Ramesh C.
2015-04-01
This study evaluated the secondary cancer risk from volumetric-modulated arc therapy (VMAT) for spine radiotherapy compared with intensity-modulated radiotherapy (IMRT) and 3-dimensional conformal radiotherapy (3DCRT). Computed tomography images of an Radiological Physics Center spine anthropomorphic phantom were exported to a treatment planning system (Pinnacle{sup 3}, version 9.4). Radiation treatment plans for spine were prepared using VMAT (dual-arc), 7-field IMRT (beam angles: 110°, 130°, 150°, 180°, 210°, 230°, and 250°), and 4-field 3DCRT technique. The mean and maximum doses, dose-volume histograms, and volumes receiving more than 2 and 4 Gy to organs at risk (OARs) were calculated and compared. The lifetimemore » risk for secondary cancers was estimated according to the National Cancer Registry Programme Report 116. VMAT delivered the lowest maximum dose to the esophagus (4.03 Gy), bone (8.11 Gy), heart (2.11 Gy), spinal cord (6.45 Gy), and whole lung (5.66 Gy) as compared with other techniques (IMRT and 3DCRT). The volumes of OAR (esophagus) receiving more than 4 Gy were 0% for VMAT, 27.06% for IMRT, and up to 32.35% for 3DCRT. The estimated risk for secondary cancer in the respective OAR is considerably lower in VMAT compared with other techniques. The results of maximum doses and volumes of OARs suggest that the risk of secondary cancer induction for the spine in VMAT is lower than IMRT and 3DCRT, whereas VMAT has the best target coverage compared with the other techniques.« less
Intensity-Modulated Radiation Therapy in the Salvage of Locally Recurrent Nasopharyngeal Carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qiu Sufang; Department of Radiation Oncology, National University Cancer Institute, National University Health System, National University of Singapore; Lin Shaojun
2012-06-01
Purpose: Local recurrences of nasopharyngeal carcinoma (NPC) may be salvaged by reirradiation with conventional techniques, but with significant morbidity. Intensity-modulated radiation therapy (IMRT) may improve the therapeutic ratio by reducing doses to normal tissue. The aim of this study was to address the efficacy and toxicity profile of IMRT for a cohort of patients with locally recurrent NPC. Methods and Materials: Between August 2003 and June 2009, 70 patients with radiologic or pathologically proven locally recurrent NPC were treated with IMRT. The median time to recurrence was 30 months after the completion of conventional radiation to definitive dose. Fifty-seven percentmore » of the tumors were classified asrT3-4. The minimum planned doses were 59.4 to 60 Gy in 1.8- to 2-Gy fractions per day to the gross disease with margins, with or without chemotherapy. Results: The median dose to the recurrent tumor was 70 Gy (range, 50-77.4 Gy). Sixty-five patients received the planned radiation therapy; 5 patients received between 50 and 60 Gy because of acute side effects. With a median follow-up time of 25 months, the rates of 2-year locoregional recurrence-free survival, disease-free survival, and overall survival were 65.8%, 65.8%, and 67.4%, respectively. Moderate to severe late toxicities were noted in 25 patients (35.7%). Eleven patients (15.7%) had posterior nasal space ulceration, 17 (24.3%) experienced cranial nerve palsies, 12 (17.1%) had trismus, and 12 (17.1%) experienced deafness. Extended disease-free interval (relative risk 2.049) and advanced T classification (relative risk 3.895) at presentation were adverse prognostic factors. Conclusion: Reirradiation with IMRT provides reasonable long-term control in patients with locally recurrent NPC.« less
Radiological Protection in Space: Indication from the ICRP Task Group
NASA Astrophysics Data System (ADS)
Dietze, Günther
In 2007 the International Commission on Radiological Protection (ICRP) has established a Task Group (Radiation Protection in Space) dealing with the problems of radiation protection of astronauts in space missions. Its first task is a report on "Assessment of Radiation Exposure of Astronauts in Space". When the ICRP published its general recommendations for radiological protection in 2007 (ICRP Publication 103 following ICRP Publication 60 (1991)) it was obvious that these recommendations do not really consider the special situation of astronauts in space. The radiation field with its high content of charged particles of very high energies strongly differs from usual radiation fields on ground. For example, this has consequences for the assessment of doses in the body of astronauts. The ICRP Task Group has discussed this situation and the presentation will deal with some consequences for the concept of radiation dosimetry and radiological protection in space. This includes e. g. the assessment of organ doses and the application of the effective dose concept with its definition of radiation weighting factors. Radiation quality of high energy heavy ions may be defined different than usually performed on ground. An approach of using the quality factor concept in the definition of an "effective dose" is favored for application in space missions similar to the method proposed in NCRP Report 142. New data calculated on the basis of the reference anthropomorphic voxel phantoms recommended by ICRP support this procedure. Individual dosimetry is a further subject of discussion in the Task Group. While the operational dose equivalent quantities generally in use in radiation protection on ground are not helpful for applications in space, different procedures of the assessment of organ and effective doses are applied. The Task Group is dealing with this situation.
Yurt, Ayşegül; Cavuşoğlu, Berrin; Günay, Türkan
2014-06-01
In this study, we evaluated the knowledge and perception and mitigation of hazards involved in radiological examinations, focusing on healthcare personnel who are not in radiation-related occupations, but who use ionising radiation as a part of their work. A questionnaire was applied to physicians, nurses, technicians and other staff working in different clinics that use radiation in their work, in order to evaluate their knowledge levels about ionizing radiation and their awareness about radiation doses resulting from radiological examinations. The statistical comparisons between the groups were analyzed with the Kruskal Wallis test using the SPSS program. Ninety two participants took part in the study. Their level of knowledge about ionizing radiation and doses in radiological examinations were found to be very weak. The number of correct answers of physicians, nurses, medical technicians and other personnel groups were 15.7±3.7, 13.0±4.0, 10.1±2.9 and 11.8±4.0, respectively. In the statistical comparison between the groups, the level of knowledge of physicians was found to be significantly higher than the level of the other groups (p=0.005). The present study demonstrated that general knowledge in relation to radiation, radiation protection, health risks and doses used for radiological applications are insufficient among health professions using with ionizing radiation in their work.
ERIC Educational Resources Information Center
Solomon, Frederick; And Others.
This document consists of three modules. The first looks at applications of analysis to medical radiology. The goals are to provide: 1) acquaintance with a significant applied mathematics problem utilizing Fourier Transforms; 2) generalization of the Fourier Transforms to two dimensions; 3) practice with Fourier Transforms; and 4) introduction to…
Zotova, R; Vassileva, J; Hristova, J; Pirinen, M; Järvinen, H
2012-06-01
A national study on patient dose values in interventional radiology and cardiology was performed in order to assess current practice in Bulgaria, to estimate the typical patient doses and to propose reference levels for the most common procedures. Fifteen units and more than 1,000 cases were included. Average values of the measured parameters for three procedures-coronary angiography (CA), combined procedure (CA + PCI) and lower limb arteriography (LLA)--were compared with data published in the literature. Substantial variations were observed in equipment and procedure protocols used. This resulted in variations in patient dose: air-kerma area product ranges were 4-339, 6-1,003 and 0.2-288 Gy cm(2) for CA, CA + PCI and LLA respectively. Reference levels for air kerma-area product were proposed: 40 Gy cm(2) for CA, 140 Gy cm(2) for CA + PCI and 45 Gy cm(2) for LLA. Auxiliary reference intervals were proposed for other dose-related parameters: fluoroscopy time, number of images and entrance surface air kerma rate in fluoroscopy and cine mode. There is an apparent necessity for improvement in the classification of peripheral procedures and for standardisation of the protocols applied. It is important that patient doses are routinely recorded and compared with reference levels. • Patient doses in interventional radiology are high and vary greatly • Better standardisation of procedures and techniques is needed to improve practice • Dose reference levels for most common procedures are proposed.
Nagata, Koichi; Pethel, Timothy D
2017-07-01
Although anisotropic analytical algorithm (AAA) and Acuros XB (AXB) are both radiation dose calculation algorithms that take into account the heterogeneity within the radiation field, Acuros XB is inherently more accurate. The purpose of this retrospective method comparison study was to compare them and evaluate the dose discrepancy within the planning target volume (PTV). Radiation therapy (RT) plans of 11 dogs with intranasal tumors treated by radiation therapy at the University of Georgia were evaluated. All dogs were planned for intensity-modulated radiation therapy using nine coplanar X-ray beams that were equally spaced, then dose calculated with anisotropic analytical algorithm. The same plan with the same monitor units was then recalculated using Acuros XB for comparisons. Each dog's planning target volume was separated into air, bone, and tissue and evaluated. The mean dose to the planning target volume estimated by Acuros XB was 1.3% lower. It was 1.4% higher for air, 3.7% lower for bone, and 0.9% lower for tissue. The volume of planning target volume covered by the prescribed dose decreased by 21% when Acuros XB was used due to increased dose heterogeneity within the planning target volume. Anisotropic analytical algorithm relatively underestimates the dose heterogeneity and relatively overestimates the dose to the bone and tissue within the planning target volume for the radiation therapy planning of canine intranasal tumors. This can be clinically significant especially if the tumor cells are present within the bone, because it may result in relative underdosing of the tumor. © 2017 American College of Veterinary Radiology.
Dose Matters: FDA's Guidance on Children's X-rays
... Consumers Home For Consumers Consumer Updates Dose Matters: FDA's Guidance on Children's X-rays Share Tweet Linkedin ... extra care to “child size” the radiation dose. FDA’s Role The FDA's Center for Devices and Radiological ...
Occupational radiation doses during interventional procedures
NASA Astrophysics Data System (ADS)
Nuraeni, N.; Hiswara, E.; Kartikasari, D.; Waris, A.; Haryanto, F.
2016-03-01
Digital subtraction angiography (DSA) is a type of fluoroscopy technique used in interventional radiology to clearly visualize blood vessels in a bony or dense soft tissue environment. The use of DSA procedures has been increased quite significantly in the Radiology departments in various cities in Indonesia. Various reports showed that both patients and medical staff received a noticeable radiation dose during the course of this procedure. A study had been carried out to measure these doses among interventionalist, nurse and radiographer. The results show that the interventionalist and the nurse, who stood quite close to the X-ray beams compared with the radiographer, received radiation higher than the others. The results also showed that the radiation dose received by medical staff were var depending upon the duration and their position against the X-ray beams. Compared tothe dose limits, however, the radiation dose received by all these three medical staff were still lower than the limits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallner, Christian; Rall, Anna-Maria; Thummerer, Severin
In order to assess the risk of radiological consequences of incidents and accidents in nuclear facilities it is important to contemplate their frequency of occurrence. It has to be shown that incidents and accidents occur sufficiently seldom according to their radiological consequences i. e. the occurrence frequency of radiological doses has to be limited. This is even demanded by the German radiation protection ordinance (StrlSchV), which says that in nuclear facilities other than nuclear power plants (NPP) in operation and for decommissioning, the occurrence frequency of incidents and accidents shall be contemplated in order to prove the design of safetymore » measures and safety installations. Based on the ideas of the ICRP64, we developed a risk based assessment concept for nuclear facilities, which fulfils the requirements of the German regulations concerning dose limits in normal operation and design basis accidents. The general use of the concept is dedicated to nuclear facilities other than nuclear power plants (NPP) in operation and for decommissioning, where the regulation of risk assessment is less sophisticated. The concept specifies occurrence frequency limits for radiation exposure dose ranges, i. e. the occurrence frequency of incidents and accidents has to be limited according to their radiological effects. To apply this concept, scenarios of incidents and accidents are grouped in exposition classes according to their resulting potential effective dose to members of the general public. The occurrence frequencies of the incidents and accidents are summarized in each exposition class whereas the sum must not exceed the frequency limits mentioned above. In the following we introduce the application of this concept in the assessment of the potential radiological consequences of the decommissioning of a nuclear research reactor. We carried out this assessment for the licensing process of the decommissioning on behalf of German authorities. (authors)« less
Radiological characteristics of MRI-based VIP polymer gel under carbon beam irradiation
NASA Astrophysics Data System (ADS)
Maeyama, T.; Fukunishi, N.; Ishikawa, K. L.; Furuta, T.; Fukasaku, K.; Takagi, S.; Noda, S.; Himeno, R.; Fukuda, S.
2015-02-01
We study the radiological characteristics of VIP polymer gel dosimeters under carbon beam irradiation with energy of 135 and 290 AMeV. To evaluate dose response of VIP polymer gels, the transverse (or spin-spin) relaxation rate R2 of the dosimeters measured by magnetic resonance imaging (MRI) as a function of linear energy transfer (LET), rather than penetration depth, as is usually done in previous reports. LET is evaluated by use of the particle transport simulation code PHITS. Our results reveal that the dose response decreases with increasing dose-averaged LET and that the dose response-LET relation also varies with incident carbon beam energy. The latter can be explained by taking into account the contribution from fragmentation products.
The leaded apron revisited: does it reduce gonadal radiation dose in dental radiology?
Wood, R E; Harris, A M; van der Merwe, E J; Nortjé, C J
1991-05-01
A tissue-equivalent anthropomorphic human phantom was used with a lithium fluoride thermoluminescent dosimetry system to evaluate the radiation absorbed dose to the ovarian and testicular region during dental radiologic procedures. Measurements were made with and without personal lead shielding devices consisting of thyroid collar and apron of 0.25 mm lead thickness equivalence. The radiation absorbed dose with or without lead shielding did not differ significantly from control dosimeters in vertex occlusal and periapical views (p greater than 0.05). Personal lead shielding devices did reduce gonadal dose in the case of accidental exposure (p less than 0.05). A leaded apron of 0.25 mm lead thickness equivalent was permeable to radiation in direct exposure testing.
Radiation exposure levels within timber industries in Calabar, Nigeria
Inyang, S. O.; Inyang, I. S.; Egbe, N. O.
2009-01-01
The UNSCEAR (2000) observed that there could be some exposure at work which would require regulatory control but is not really considered. This study was, therefore, set up to evaluate the effective dose in timber industries in Calabar, Nigeria to determine if the evaluated dose levels could lead to any radiological health effect in the workers, and also determine if the industries require regulatory control. The gamma ray exposure at four timber industries measured using an exposure meter were converted to effective dose and compared with the public and occupational values. The evaluated effective dose values in the timber industries were below public and occupational exposure limits and may not necessarily result in any radiological health hazard. Therefore, they may not require regulatory control. PMID:20098544
Radiation Exposure in X-Ray and CT Examinations
... disease. See the X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety page for more information. top of page ... and Radiation Safety X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Videos related to Radiation Dose in X- ...
Wang, C; Mo, S F; Zhang, J B; Li, J R; Huang, R L; Tan, H Y
2017-08-20
Objective: To determine the personal dose level of radiation workers in medical institutions at the municipal level and below in a city, and to provide a scientific support for strengthening the radiation protection in the city's medical institutions. Methods: Information of the successful applicants for the "Radiation Worker Permit" from 174 medical institutions at the municipal level and below was collected from October 1, 2011 to December 31, 2014. The annual effective dose was calculated based on the personal dose monitoring report, and indicators including sex, permit application time, hospital level, type of occupational radiation, length of radiation work, blood test, and micronucleated lymphocyte rate were analyzed. Results: Of the 1 143 radiation worker permit applications submitted by medical institutions the municipal level and below in this city from 2011 to 2014, 1 123 provided at least one personal dose monitoring report. The annual effective dose of the radiation workers was 0-4.76 mSv (mean 0.31±0.40 mSv) , and the collective annual effective dose was 351.96 mSv. The annual effective dose was significantly different between radiation workers with different times of permit application, hospital levels, and types of occupational radiation ( P <0.05) . Interventional radiology workers had the highest annual effective dose (0.63 mSv) , and annual effective dose was significantly different between interventional radiology workers with different lengths of radiation work ( H =10.812, P <0.05) . Conclusion: The personal radiation dose of radiation workers in medical institutions at the municipal level and below in this city is maintained at a relatively low level, suggesting that the occupational environment is relatively safe for these workers. However, more focus should be placed on clinical interventional radiology workers.
SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sina, S; Zeinali, B; Karimipourfard, M
Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface ofmore » Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities.« less
Etard, Cécile; Bigand, Emeline; Salvat, Cécile; Vidal, Vincent; Beregi, Jean Paul; Hornbeck, Amaury; Greffier, Joël
2017-10-01
A national retrospective survey on patient doses was performed by the French Society of Medical physicists to assess reference levels (RLs) in interventional radiology as required by the European Directive 2013/59/Euratom. Fifteen interventional procedures in neuroradiology, vascular radiology and osteoarticular procedures were analysed. Kerma area product (KAP), fluoroscopy time (FT), reference air kerma and number of images were recorded for 10 to 30 patients per procedure. RLs were calculated as the 3rd quartiles of the distributions. Results on 4600 procedures from 36 departments confirmed the large variability in patient dose for the same procedure. RLs were proposed for the four dosimetric estimators and the 15 procedures. RLs in terms of KAP and FT were 90 Gm.cm 2 and 11 mins for cerebral angiography, 35 Gy.cm 2 and 16 mins for biliary drainage, 75 Gy.cm 2 and 6 mins for lower limbs arteriography and 70 Gy.cm 2 and 11 mins for vertebroplasty. For these four procedures, RLs were defined according to the complexity of the procedure. For all the procedures, the results were lower than most of those already published. This study reports RLs in interventional radiology based on a national survey. Continual evolution of practices and technologies requires regular updates of RLs. • Delivered dose in interventional radiology depends on procedure, practice and patient. • National RLs are proposed for 15 interventional procedures. • Reference levels (RLs) are useful to benchmark practices and optimize protocols. • RLs are proposed for kerma area product, air kerma, fluoroscopy time and number of images. • RLs should be adapted to the procedure complexity and updated regularly.
Pregnancy and Radiation Protection
NASA Astrophysics Data System (ADS)
Gerogiannis, J.; Stefanoyiannis, A. P.
2010-01-01
Several modalities are currently utilized for diagnosis and therapy, by appropriate application of x-rays. In diagnostic radiology, interventional radiology, radiotherapy, interventional cardiology, nuclear medicine and other specialties radiation protection of a pregnant woman as a patient, as well as a member of the operating personnel, is of outmost importance. Based on radiation risk, the termination of pregnancy is not justified if foetal doses are below 100 mGy. For foetal doses between 100 and 500 mGy, a decision is reached on a case by case basis. In Diagnostic Radiology, when a pregnant patient takes an abdomen CT, then an estimation of the foetus' dose is necessary. However, it is extremely rare for the dose to be high enough to justify an abortion. Radiographs of the chest and extremities can be done at any period of pregnancy, provided that the equipment is functioning properly. Usually, the radiation risk is lower than the risk of not undergoing a radiological examination. Radiation exposure in uterus from diagnostic radiological examinations is unlikely to result in any deleterious effect on the child, but the possibility of a radiation-induced effect can not be entirely ruled out. The effects of exposure to radiation on the foetus depend on the time of exposure, the date of conception and the absorbed dose. Finally, a pregnant worker can continue working in an x-ray department, as long as there is reasonable assurance that the foetal dose can be kept below 1 mGy during the pregnancy. Nuclear Medicine diagnostic examinations using short-lived radionuclides can be used for pregnant patient. Irradiation of the foetus results from placental transfer and distribution of radiopharmaceuticals in the foetal tissues, as well as from external irradiation from radioactivity in the mother's organ and tissues. As a rule, a pregnant patient should not undergo therapy with radionuclide, unless it is crucial for her life. In Radiotherapy, the patient, treating oncologist, other team and family members should carefully discuss for the decision of abortion. Important factors must be considered such as the stage and aggressiveness of the tumour, the location of the tumour, the stage of pregnancy, various therapies etc.
Pregnancy and Radiation Protection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerogiannis, J.; Stefanoyiannis, A. P.
Several modalities are currently utilized for diagnosis and therapy, by appropriate application of x-rays. In diagnostic radiology, interventional radiology, radiotherapy, interventional cardiology, nuclear medicine and other specialties radiation protection of a pregnant woman as a patient, as well as a member of the operating personnel, is of outmost importance. Based on radiation risk, the termination of pregnancy is not justified if foetal doses are below 100 mGy. For foetal doses between 100 and 500 mGy, a decision is reached on a case by case basis. In Diagnostic Radiology, when a pregnant patient takes an abdomen CT, then an estimation ofmore » the foetus' dose is necessary. However, it is extremely rare for the dose to be high enough to justify an abortion. Radiographs of the chest and extremities can be done at any period of pregnancy, provided that the equipment is functioning properly. Usually, the radiation risk is lower than the risk of not undergoing a radiological examination. Radiation exposure in uterus from diagnostic radiological examinations is unlikely to result in any deleterious effect on the child, but the possibility of a radiation-induced effect can not be entirely ruled out. The effects of exposure to radiation on the foetus depend on the time of exposure, the date of conception and the absorbed dose. Finally, a pregnant worker can continue working in an x-ray department, as long as there is reasonable assurance that the foetal dose can be kept below 1 mGy during the pregnancy. Nuclear Medicine diagnostic examinations using short-lived radionuclides can be used for pregnant patient. Irradiation of the foetus results from placental transfer and distribution of radiopharmaceuticals in the foetal tissues, as well as from external irradiation from radioactivity in the mother's organ and tissues. As a rule, a pregnant patient should not undergo therapy with radionuclide, unless it is crucial for her life. In Radiotherapy, the patient, treating oncologist, other team and family members should carefully discuss for the decision of abortion. Important factors must be considered such as the stage and aggressiveness of the tumour, the location of the tumour, the stage of pregnancy, various therapies etc.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, D.
Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less
İnal, Tolga; Ataç, Gökçe
2014-01-01
We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.
Assessment of medical occupational radiation doses in Costa Rica.
Mora, P; Acuña, M
2011-09-01
Participation of the University of Costa Rica (UCR) in activities in an IAEA Regional Project RLA/9/066 through training, equipment and expert missions, has enabled to setting up of a national personal monitoring laboratory. Since 2007, the UCR has been in charge of monitoring around 1800 medical radiation workers of the Social Security System. Individual external doses are measured with thermoluminescent dosemeter using a Harshaw 6600 Plus reader. The service has accreditation with ISO/IEC 17025:2005. Distribution of monitored medical personnel is as follows: 83 % in diagnostic radiology, 6 % in nuclear medicine and 6 % in radiotherapy. Preliminary values for the 75 percentile of annual H(p)(10) in mSv are: radiology 0.37; interventional radiology 0.41; radiotherapy 0.53 and nuclear medicine 1.55. The service provided by the UCR in a steady and reliable way can help to implement actions to limit the doses received by the medical workers and optimise their radiation protection programs.
Optimization of exposure parameters for pediatric chest x-ray imaging
NASA Astrophysics Data System (ADS)
Park, Hye-Suk; Kim, Ye-Seul; Kim, Hee-Joung
2012-03-01
The pediatric patients are more susceptible to the effects of ionizing radiation than adults. Pediatric patients are smaller, more radiosensitive than adult patients and many cannot stand unassisted. Their characteristics affect the method of imaging projection and how dose is optimized. The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kV in 10 kV increments at the focus-to-detector distance of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at same effective dose. The results showed that the eDQE was largest at 60 kVp without and with an anti-scatter grid. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing focus-to-detector distance because of the greater effective modulation transfer function (eMTF) with the lower focal spot blurring. In conclusion, for pediatric patients, the amount of scattered radiation is less, and the amount of grid attenuation increased unnecessary radiation dose.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jannik, G. T.; Dixon, K. L.
This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2015 Savannah River Site (SRS) atmospheric and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios - such as the consumption of deer meat, fish, and goat milk.
An evaluation of the impact of digital imaging on radiographic practice and patient doses
NASA Astrophysics Data System (ADS)
Horrocks, J.; Violaki, K.
2015-09-01
Direct digital imaging technology was implemented in all areas in general and mobile radiology at Barts and the Royal London Hospitals in 2012. Evidence from recent radiation incident investigations indicates optimum exposure factors are not consistently selected, with the greater dynamic range of the digital detectors allowing sub-optimal practice. To investigate further patient dose data were extracted from the Radiology Information System for adult chest X-ray examinations in 2014, covering over 50,000 studies in the Trust. Chest X-ray examinations were selected as they are low dose but frequent examinations. The patient dose data were evaluated taking into account X-ray system type and detector performance measurements, and individual cases studies were used to highlight where practice can be improved.
Calibration of an eye lens dosemeter in terms of Hp(3) to be used in interventional radiology
NASA Astrophysics Data System (ADS)
Borges, F. L. S.; Guimarães, M. C.; Da Silva, T. A.; Nogueira Tavares, M. S.
2014-11-01
Recently, the International Commission on Radiological Protection has reviewed epidemiological evidences suggesting that there were tissue reaction effects in the eye lens below the previously considered absorbed dose threshold. A new statement related to the eye lens was issued that changed the absorbed dose threshold and reduced the dose limits for occupationally exposed persons. As consequence, some planned exposures require eye lens dosimetry and a debate was raised on the adequacy of the dosimetric quantity and on its method of measurement. The aim of this work was to study the methodology for calibrating the EYE-DTM holder with a TLD-100H Harshaw chip detector and to determine its angular and energy dependences in terms of personal dose equivalent, Hp(3).
[No exchange of information without technology : modern infrastructure in radiology].
Hupperts, H; Hermann, K-G A
2014-01-01
Modern radiology cannot accomplish the daily numbers of examinations without supportive technology. Even though technology seems to be becoming increasingly more indispensable, business continuity should be ensured at any time and if necessary even with a limited technical infrastructure by business continuity management. An efficient information security management system forms the basis. The early radiology information systems were islands of information processing. A modern radiology department must be able to be modularly integrated into an informational network of a bigger organization. The secondary use of stored data for clinical decision-making support poses new challenges for the integrity of the data or systems because medical knowledge is displayed and provided in a context of treatment. In terms of imaging the creation and distribution radiology services work in a fully digital manner which is often different for radiology reports. Legally secure electronic diagnostic reports require a complex technical infrastructure; therefore, diagnostic findings still need to be filed as a paper document. The internal exchange and an improved dose management can be simplified by systems which continuously and automatically record the doses and thus provide the possibility of permanent analysis and reporting. Communication between patient and radiologist will gain ongoing importance. Intelligent use of technology will convey this to the radiologist and it will facilitate the understanding of the information by the patient.
ICRP Publication 139: Occupational Radiological Protection in Interventional Procedures.
López, P Ortiz; Dauer, L T; Loose, R; Martin, C J; Miller, D L; Vañó, E; Doruff, M; Padovani, R; Massera, G; Yoder, C
2018-03-01
In recent publications, such as Publications 117 and 120, the Commission provided practical advice for physicians and other healthcare personnel on measures to protect their patients and themselves during interventional procedures. These measures can only be effective if they are encompassed by a framework of radiological protection elements, and by the availability of professionals with responsibilities in radiological protection. This framework includes a radiological protection programme with a strategy for exposure monitoring, protective garments, education and training, and quality assurance of the programme implementation. Professionals with responsibilities in occupational radiological protection for interventional procedures include: medical physicists; radiological protection specialists; personnel working in dosimetry services; clinical applications support personnel from the suppliers and maintenance companies; staff engaged in training, standardisation of equipment, and procedures; staff responsible for occupational health; hospital administrators responsible for providing financial support; and professional bodies and regulators. This publication addresses these elements and these audiences, and provides advice on specific issues, such as assessment of effective dose from dosimeter readings when an apron is worn, estimation of exposure of the lens of the eye (with and without protective eyewear), extremity monitoring, selection and testing of protective garments, and auditing the interventional procedures when occupational doses are unusually high or low (the latter meaning that the dosimeter may not have been worn).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Casimiro de Deus Cardoso, Cejana; Giordani, Adelmo Jose; Borri Wolosker, Angela Maria
Purpose: To evaluate the clinical and radiologic response of patients with Graves' ophthalmopathy given low-dose orbital radiotherapy (RT) with a protracted fractionation. Methods and Materials: Eighteen patients (36 orbits) received orbital RT with a total dose of 10 Gy, fractionated in 1 Gy once a week over 10 weeks. Of these, 9 patients received steroid therapy as well. Patients were evaluated clinically and radiologically at 6 months after treatment. Clinical response assessment was carried out using three criteria: by physical examination, by a modified clinical activity score, and by a verbal questionnaire considering the 10 most common signs and symptomsmore » of the disease. Radiologic response was assessed by magnetic resonance imaging. Results: Improvement in ocular pain, palpebral edema, visual acuity, and ocular motility was observed in all patients. Significant decrease in symptoms such as tearing (p < 0.001) diplopia (p = 0.008), conjunctival hyperemia (p = 0.002), and ocular grittiness (p = 0.031) also occurred. Magnetic resonance imaging showed decrease in ocular muscle thickness and in the intensity of the T2 sequence signal in the majority of patients. Treatments were well tolerated, and to date no complications from treatment have been observed. There was no statistical difference in clinical and radiologic response between patients receiving RT alone and those receiving RT plus steroid therapy. Conclusion: RT delivered in at a low dose and in a protracted scheme should be considered as a useful therapeutic option for patients with Graves' ophthalmopathy.« less
Paolicchi, F; Miniati, F; Bastiani, L; Faggioni, L; Ciaramella, A; Creonti, I; Sottocornola, C; Dionisi, C; Caramella, D
2016-04-01
To evaluate radiation protection basic knowledge and dose assessment for radiological procedures among Italian radiographers A validated questionnaire was distributed to 780 participants with balanced demographic characteristics and geographic distribution. Only 12.1 % of participants attended radiation protection courses on a regular basis. Despite 90 % of radiographers stating to have sufficient awareness of radiation protection issues, most of them underestimated the radiation dose of almost all radiological procedures. About 5 % and 4 % of the participants, respectively, claimed that pelvis magnetic resonance imaging and abdominal ultrasound exposed patients to radiation. On the contrary, 7.0 % of the radiographers stated that mammography does not use ionising radiation. About half of participants believed that radiation-induced cancer is not dependent on age or gender and were not able to differentiate between deterministic and stochastic effects. Young radiographers (with less than 3 years of experience) showed a higher level of knowledge compared with the more experienced radiographers. There is a substantial need for radiographers to improve their awareness of radiation protection issues and their knowledge of radiological procedures. Specific actions such as regular training courses for both undergraduate and postgraduate students as well as for working radiographers must be considered in order to assure patient safety during radiological examinations. • Radiographers should improve their knowledge on radiation protection issues. • Only 12.1 % of participants attended radiation protection courses on a regular basis. • Specific actions must be considered in order to increase knowledge and awareness.
Dell'Acqua, V; Kobiela, J; Kraja, F; Leonardi, M C; Surgo, A; Zerella, M A; Arculeo, S; Fodor, C; Ricotti, R; Zampino, M G; Ravenda, S; Spinoglio, G; Biffi, R; Bazani, A; Luraschi, R; Vigorito, S; Spychalski, P; Orecchia, R; Glynne-Jones, R; Jereczek-Fossa, B A
2018-03-28
Intensity-modulated radiotherapy (IMRT) is considered the preferred option in squamous cell canal cancer (SCAC), delivering high doses to tumor volumes while minimizing dose to surrounding normal tissues. IMRT has steep dose gradients, but the technique is more demanding as deep understanding of target structures is required. To evaluate genital marginal failure in a cohort of patients with non-metastatic SCAC treated either with IMRT or 3DCRT and concurrent chemotherapy, 117 patients with SCAC were evaluated: 64 and 53 patients were treated with IMRT and 3DCRT techniques, respectively. All patients underwent clinical and radiological examination during their follow-up. Tumor response was evaluated with response evaluation criteria in solid tumors v1.1 guideline on regular basis. All patients' data were analyzed, and patients with marginal failure were identified. Concomitant chemotherapy was administered in 97 and 77.4% of patients in the IMRT and 3DCRT groups, respectively. In the IMRT group, the median follow-up was 25 months (range 6-78). Progressive disease was registered in 15.6% of patients; infield recurrence, distant recurrence and both infield recurrence and distant recurrence were identified in 5, 4 and 1 patient, respectively. Two out of 64 patients (3.1%) had marginal failures, localized at vagina/recto-vaginal septum and left perineal region. In the 3DCRT group, the median follow-up was 71.3 months (range 6-194 months). Two out of 53 patients (3.8%) had marginal failures, localized at recto-vaginal septum and perigenital structures. The rate of marginal failures was comparable in IMRT and 3DCRT groups (χ 2 test p = 0.85). In this series, the use of IMRT for the treatment of SCAC did not increase the rate of marginal failures offering improved dose conformity to the target. Dose constraints should be applied with caution-particularly in females with involvement of the vagina or the vaginal septum.
Poort, Lucas J; Postma, Alida A; Stadler, Annika A R; Böckmann, Roland A; Hoebers, Frank J; Kessler, Peter A W H
2017-05-01
Radiotherapy in the head and neck can induce several radiologically detectable changes in bone, osteoradionecrosis (ORN) among them. The purpose is to investigate radiological changes in mandibular bone after irradiation with various doses with and without surgery and to determine imaging characteristics of radiotherapy and ORN in an animal model. Sixteen Göttingen minipigs were divided into groups and were irradiated with two fractions with equivalent doses of 0, 25, 50 and 70 Gray. Thirteen weeks after irradiation, left mandibular teeth were removed and dental implants were placed. CT-scans and MR-imaging were made before irradiation and twenty-six weeks after. Alterations in the bony structures were recorded on CT-scan and MR-imaging and scored by two head-neck radiologists. Increased signal changes on MR-imaging were associated with higher radiation doses. Two animals developed ORN clinically. Radiologically mixed signal intensities on T2-SPIR were seen. On CT-scans cortical destruction was found in three animals. Based on imaging, three animals were diagnosed with ORN. Irradiation of minipig mandibles with various doses induced damages of the mandibular bone. Imaging with CT-scan and MR-imaging showed signal and structural changes that can be interpreted as prolonged and insufficient repair of radiation induced bone damages. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Rehani, Madan M; Vano, Eliseo; Ciraj-Bjelac, Olivera; Kleiman, Norman J
2011-09-01
When this paper was about to go to press, the International Commission on Radiological Protection released a statement recommending a change in the threshold dose for the eye lens and dose limits for eye for occupationally exposed persons. It is clear that the earlier published threshold for radiation cataract is no longer valid. Epidemiological studies among Chernobyl clean-up workers, A bomb survivors, astronauts, residents of contaminated buildings, radiological technicians and recent surveys of staff in interventional rooms indicate that there is an increased incidence of lens opacities at doses below 1 Gy. Nevertheless, eye lens dosimetry is at a primitive stage and needs to be developed further. Despite uncertainties concerning dose threshold and dosimetry, it is possible to significantly reduce the risk of radiation cataract through the use of appropriate eye protection. By increasing awareness among those at risk and better adoption and increased usage of protective measures, radiation cataract can become preventable despite lowering of dose limits.
Improving education for the management of contrast reactions: an online didactic model.
Niell, Bethany L; Vartanians, Vartan M; Halpern, Elkan P
2014-02-01
Radiologists could improve their knowledge of contrast reaction management. The aim of this study was to evaluate to what degree the implementation of a didactic module resulted in improved technologist, nurse, and physician knowledge and comfort levels regarding the appropriate management of adverse reactions to contrast media. After institutional review board approval was obtained, nurses, technologists, and physicians involved in contrast administration were required to complete the educational module. Premodule and postmodule assessments were designed online. Each assessment included knowledge-based questions regarding the appropriate management of different types of contrast reactions, as well as questions regarding each respondent's comfort level with the treatment of various types of adverse contrast reactions. Comfort level was measured using a 6-point, Likert-type scale. Premodule and postmodule assessment scores were compared using McNemar's test. After module completion, physicians demonstrated a statistically significant improvement in knowledge regarding the proper administration route, concentration, and dose of intramuscular epinephrine. Physicians demonstrated significantly increased comfort with the administration of intramuscular epinephrine to adult and pediatric patients after module completion (P < .05). Module completion resulted in statistically significant improvements in respondents' comfort levels with the treatment of an adverse reaction to contrast media, although 19% of personnel still reported feeling uncomfortable after completing the module. Didactic instruction in contrast reaction management results in improved knowledge and comfort levels for physicians, nurses, and technologists. However, a significant percentage of personnel still reported feeling uncomfortable treating an adverse contrast reaction after module completion, suggesting that didactic instruction alone may be inadequate. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Imaging informatics for consumer health: towards a radiology patient portal
Arnold, Corey W; McNamara, Mary; El-Saden, Suzie; Chen, Shawn; Taira, Ricky K; Bui, Alex A T
2013-01-01
Objective With the increased routine use of advanced imaging in clinical diagnosis and treatment, it has become imperative to provide patients with a means to view and understand their imaging studies. We illustrate the feasibility of a patient portal that automatically structures and integrates radiology reports with corresponding imaging studies according to several information orientations tailored for the layperson. Methods The imaging patient portal is composed of an image processing module for the creation of a timeline that illustrates the progression of disease, a natural language processing module to extract salient concepts from radiology reports (73% accuracy, F1 score of 0.67), and an interactive user interface navigable by an imaging findings list. The portal was developed as a Java-based web application and is demonstrated for patients with brain cancer. Results and discussion The system was exhibited at an international radiology conference to solicit feedback from a diverse group of healthcare professionals. There was wide support for educating patients about their imaging studies, and an appreciation for the informatics tools used to simplify images and reports for consumer interpretation. Primary concerns included the possibility of patients misunderstanding their results, as well as worries regarding accidental improper disclosure of medical information. Conclusions Radiologic imaging composes a significant amount of the evidence used to make diagnostic and treatment decisions, yet there are few tools for explaining this information to patients. The proposed radiology patient portal provides a framework for organizing radiologic results into several information orientations to support patient education. PMID:23739614
ASSESSMENT OF EYE LENS DOSES IN INTERVENTIONAL RADIOLOGY: A SIMULATION IN LABORATORY CONDITIONS.
Čemusová, Z; Ekendahl, D; Judas, L
2016-09-01
As workers in interventional radiology belong to one of the most occupationally exposed groups, methods for sufficiently accurate quantification of their external exposure are sought. The objective of the authors' experiment was to investigate the relations between eye lens dose and Hp(10), Hp(3) or Hp(0.07) values measured with a conventional whole-body personal thermoluminescence dosemeter (TLD). Conditions of occupational exposure during common interventional procedures were simulated in laboratory. An anthropomorphic phantom represented a physician. The TLDs were fixed to the phantom in different locations that are common for purposes of personal dosimetry. In order to monitor the dose at the eye lens level during the exposures, a special thermoluminescence eye dosemeter was fixed to the phantom's temple. Correlations between doses measured with the whole-body and the eye dosemeters were found. There are indications that personnel in interventional radiology do not need to be unconditionally equipped with additional eye dosemeters, especially if an appropriate whole-body dosimetry system has been already put into practice. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Chang, Lienard A.
In the event of a radiological accident or attack, it is important to estimate the organ doses to those exposed. In general, it is difficult to measure organ dose directly in the field and therefore dose conversion coefficients (DCC) are needed to convert measurable values such as air kerma to organ dose. Previous work on these coefficients has been conducted mainly for adults with a focus on radiation protection workers. Hence, there is a large gap in the literature for pediatric values. This study coupled a Monte Carlo N-Particle eXtended (MCNPX) code with International Council of Radiological Protection (ICRP)-adopted University of Florida and National Cancer Institute pediatric reference phantoms to calculate a comprehensive list of dose conversion coefficients (mGy/mGy) to convert air-kerma to organ dose. Parameters included ten phantoms (newborn, 1-year, 5-year, 10-year, 15-year old male and female), 28 organs over 33 energies between 0.01 and 20 MeV in six (6) irradiation geometries relevant to a child who might be exposed to a radiological release: anterior-posterior (AP), posterior-anterior (PA), right-lateral (RLAT), left-lateral (LLAT), rotational (ROT), and isotropic (ISO). Dose conversion coefficients to the red bone marrow over 36 skeletal sites were also calculated. It was hypothesized that the pediatric organ dose conversion coefficients would follow similar trends to the published adult values as dictated by human anatomy, but be of a higher magnitude. It was found that while the pediatric coefficients did yield similar patterns to that of the adult coefficients, depending on the organ and irradiation geometry, the pediatric values could be lower or higher than that of the adult coefficients.
Pilishvili, Tamara; Chernyshova, Liudmyla; Bondarenko, Anastasia; Lapiy, Fedir; Sychova, Irina; Cohen, Adam; Flannery, Brendan; Hajjeh, Rana
2013-07-01
Haemophilus influenzae type b (Hib) conjugate vaccine was included into the national vaccination schedule of Ukraine in 2006. The objective of this study was to demonstrate the effectiveness of Hib conjugate vaccine against radiologically-confirmed hospitalized pneumonia in children. Children <2 years old with radiologically confirmed pneumonia admitted to 11 participating hospitals in Kiev and Dnepropetrovsk between April 2007 and June 2009 were included in a case-control evaluation. Four controls were matched to each case by date of birth (within 14 days) and outpatient clinic. We estimated ORs for vaccination and vaccine effectiveness ((1 - OR)*100%) using conditional logistic regression, adjusting for comorbid conditions and contraindications for vaccination. We enrolled 188 case-children and 735 controls. Median age was 16 months (range 4-24 months). Fifty-one percent of cases and 67% of controls received ≥1 doses of Hib conjugate vaccine; 26% of cases and 37% of controls received ≥3 doses. The effectiveness of ≥1 dose Hib conjugate vaccine was estimated at 45% (95% CI 18%-63%). Our study showed that Hib infections are important causes of hospitalized radiologically confirmed pneumonia in young children in Ukraine. Copyright © 2013. Published by Mosby, Inc.
Beresford, Nicholas A; Copplestone, David
2011-07-01
The recent events at the Fukushima Daiichi nuclear power plant in Japan have raised questions over the effects of radiation in the environment. This article considers what we have learned about the radiological consequences for the environment from the Chernobyl accident, Ukraine, in April 1986. The literature offers mixed opinions of the long-term impacts on wildlife close to the Chernobyl plant, with some articles reporting significant effects at very low dose rates (below natural background dose rate levels in, for example, the United Kingdom). The lack of agreement highlights the need for further research to establish whether current radiological protection criteria for wildlife are adequate (and to determine if there are any implications for human radiological protection). Copyright © 2011 SETAC.
Jibiri, Nnamdi Norbert; Akintunde, Tawakalitu Oluwatoyin; Dambele, Musa Yusuf; Olowookere, Christopher Jimoh
2016-10-05
The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG) and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP) without cannula and with cannula were 10.68 (720.2) and 13.82 (556.4) mSv per week (and per annum), respectively. It was determined that the left hand of the personnel received higher doses than their right hand. The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99mTc-MDP in Nigerian institutions to prevent excessive doses to personnel.
Jibiri, Nnamdi Norbert; Akintunde, Tawakalitu Oluwatoyin; Dambele, Musa Yusuf; Olowookere, Christopher Jimoh
2016-01-01
Objective: The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Methods: Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG) and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. Results: The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP) without cannula and with cannula were 10.68 (720.2) and 13.82 (556.4) mSv per week (and per annum), respectively. It was determined that the left hand of the personnel received higher doses than their right hand. Conclusion: The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99mTc-MDP in Nigerian institutions to prevent excessive doses to personnel. PMID:27751973
The Effectiveness of Hypermedia Instructional Modules for Radiology Residents.
ERIC Educational Resources Information Center
Shaw, Steven G.; And Others
1995-01-01
Details the development and field testing of hypermedia training materials for teaching radiology residents at the Montreal General Hospital (Canada). Compares results of randomly teaching 24 residents with either hypermedia or traditional classroom methods. Results indicate that residents who learned with hypermedia generally performed as well as…
McKenna, Thomas; Welter, Phillip Vilar; Callen, Jessica; Martincic, Rafael; Dodd, Brian; Kutkov, Vladimir
2015-01-01
Experience from past nuclear and radiological emergencies shows that placing the radiological health hazard in perspective and having a definition of "safe" are required in order to prevent members of the public, those responsible for protecting the public (i.e., decision makers), and others from taking inappropriate and damaging actions that are not justified based on the radiological health hazard. The principle concerns of the public during a severe nuclear power plant or spent fuel pool emergency are "Am I safe?" and "What should I do to be safe?" However, these questions have not been answered to the satisfaction of the public, despite various protective actions being implemented to ensure their safety. Instead, calculated doses or various measured quantities (e.g., ambient dose rate or radionuclide concentrations) are used to describe the situation to the public without placing them into perspective in terms of the possible radiological health hazard, or if they have, it has been done incorrectly. This has contributed to members of the public taking actions that do more harm than good in the belief that they are protecting themselves. Based on established international guidance, this paper provides a definition of "safe" for the radiological health hazard for use in nuclear or radiological emergencies and a system for putting the radiological health hazard in perspective for quantities most commonly measured after a release resulting from a severe emergency at a light water reactor or its spent fuel pool.
Uncertainty analysis of absorbed dose calculations from thermoluminescence dosimeters.
Kirby, T H; Hanson, W F; Johnston, D A
1992-01-01
Thermoluminescence dosimeters (TLD) are widely used to verify absorbed doses delivered from radiation therapy beams. Specifically, they are used by the Radiological Physics Center for mailed dosimetry for verification of therapy machine output. The effects of the random experimental uncertainties of various factors on dose calculations from TLD signals are examined, including: fading, dose response nonlinearity, and energy response corrections; reproducibility of TL signal measurements and TLD reader calibration. Individual uncertainties are combined to estimate the total uncertainty due to random fluctuations. The Radiological Physics Center's (RPC) mail out TLD system, utilizing throwaway LiF powder to monitor high-energy photon and electron beam outputs, is analyzed in detail. The technique may also be applicable to other TLD systems. It is shown that statements of +/- 2% dose uncertainty and +/- 5% action criterion for TLD dosimetry are reasonable when related to uncertainties in the dose calculations, provided the standard deviation (s.d.) of TL readings is 1.5% or better.
[Regulating radiological protection and the role of health authorities].
Arias, César F
2006-01-01
This article summarizes the development of protection against ionizing radiation and explains current thinking in the field. It also looks at the decisive role that regulatory agencies for radiological protection must play and the important contributions that can be made by health authorities. The latter should take an active part in at least three aspects: the formal education of health personnel regarding radiological protection; the medical care of individuals who are accidentally overexposed, and the radiological protection of patients undergoing radiological procedures. To this end, health professionals must possess sufficient knowledge about radiological protection, promote the use of proper equipment, and apply the necessary quality assurance procedures. Through their effective intervention, national health authorities can greatly contribute to reducing unnecessary doses of radiation during medical procedures involving radiation sources and decrease the chances that radiological accidents will take place.
Patient Radiation Doses from Diagnostic Radiology.
ERIC Educational Resources Information Center
Hart, D.
1996-01-01
Explains how x-ray doses to patients are measured. Describes how different techniques expose patients to differing amounts of ionizing radiation. Compares these figures with other natural and man-made sources. (Author/MKR)
NASA Astrophysics Data System (ADS)
Abdullahi, S.; Ismail, A. F.; Samat, S. B.; Yasir, M. S.
2018-04-01
The activity concentration and radiological risk of commonly used flooring materials (tiles) in Malaysia were studied. The natural radionuclide concentrations of 226Ra, 232Th and 40K were measured using high-purity germanium detector. The average concentration of 226Ra, 232Th and 40K in the samples were 65.75±1.1 Bq kg-1, 61.92±1.43 Bq kg-1 and 617.77±6.72 Bq kg-1 respectively. The mean concentration of radium equivalent activity, absorbed dose rate, external and internal hazard indices and annual effective dose equivalent were 195.21±2.88 Bq kg-1, 92.75±1.27 nGy h-1, 0.53±0.01, 0.7±0.01 and 0.44±0.0 mSv y-1 respectively. The aim was to assess the possible radiological risks attributed from the tile materials. Even though, the activity concentrations were higher than worldwide average values, but none of the radiological impact parameters exceeded the maximum recommended values. Hence, it was concluded that, contribution of tiles to radiation exposure is negligible and therefore, radiologically safe to use as building materials.
Clinically oriented three-year medical physics curriculum: a new design for the future.
Nachiappan, Arun C; Lee, Stephen R; Willis, Marc H; Galfione, Matthew R; Chinnappan, Raj R; Diaz-Marchan, Pedro J; Bushong, Stewart C
2012-09-01
Medical physics instruction for diagnostic radiology residency at our institution has been redesigned with an interactive and image-based approach that encourages clinical application. The new medical physics curriculum spans the first 3 years of radiology residency and is integrated with the core didactic curriculum. Salient features include clinical medical physics conferences, fundamentals of medical physics lectures, practicums, online modules, journal club, and a final review before the American Board of Radiology core examination.
A kinematic model to estimate effective dose of radioactive substances in a human body
NASA Astrophysics Data System (ADS)
Sasaki, S.; Yamada, T.
2013-05-01
The great earthquake occurred in the north-east area in Japan in March 11, 2011. Facility system to control Fukushima Daiichi nuclear power station was completely destroyed by the following giant tsunami. From the damaged reactor containment vessels, an amount of radioactive substances had leaked and diffused in the vicinity of this station. Radiological internal exposure became a serious social issue both in Japan and all over the world. The present study provides an easily understandable, kinematic-based model to estimate the effective dose of radioactive substances in a human body by simplifying the complicated mechanism of metabolism. International Commission on Radiological Protection (ICRP) has developed a sophisticated model, which is well-known as a standard method to calculate the effective dose for radiological protection. However, owing to that ICRP method is fine, it is rather difficult for non-professional people of radiology to gasp the whole images of the movement and the influences of radioactive substances in a human body. Therefore, in the present paper we propose a newly-derived and easily-understandable model to estimate the effective dose. The present method is very similar with the traditional and conventional tank model in hydrology. Ingestion flux of radioactive substances corresponds to rain intensity and the storage of radioactive substances to the water storage in a basin in runoff analysis. The key of the present method is to estimate the energy radiated in the radioactive nuclear disintegration of an atom by using classical theory of β decay and special relativity for various kinds of radioactive atoms. The parameters used in this model are only physical half-time and biological half-time, and there are no operational parameters or coefficients to adjust our theoretical runoff to ICRP. Figure shows the time-varying effective dose with ingestion duration, and we can confirm the validity of our model. The time-varying effective dose with ingestion duration
Asaduzzaman, Khandoker; Mannan, Farhana; Khandaker, Mayeen Uddin; Farook, Mohideen Salihu; Elkezza, Aeman; Amin, Yusoff Bin Mohd; Sharma, Sailesh; Abu Kassim, Hasan Bin
2015-01-01
The concentrations of primordial radionuclides (226Ra, 232Th and 40K) in commonly used building materials (brick, cement and sand), the raw materials of cement and the by-products of coal-fired power plants (fly ash) collected from various manufacturers and suppliers in Bangladesh were determined via gamma-ray spectrometry using an HPGe detector. The results showed that the mean concentrations of 226Ra, 232Th and 40K in all studied samples slightly exceeded the typical world average values of 50 Bq kg(-1), 50 Bq kg(-1) and 500 Bq kg(-1), respectively. The activity concentrations (especially 226Ra) of fly-ash-containing cement in this study were found to be higher than those of fly-ash-free cement. To evaluate the potential radiological risk to individuals associated with these building materials, various radiological hazard indicators were calculated. The radium equivalent activity values for all samples were found to be lower than the recommended limit for building materials of 370 Bq kg(-1), with the exception of the fly ash. For most samples, the values of the alpha index and the radiological hazard (external and internal) indices were found to be within the safe limit of 1. The mean indoor absorbed dose rate was observed to be higher than the population-weighted world average of 84 nGy h(-1), and the corresponding annual effective dose for most samples fell below the recommended upper dose limit of 1 mSv y(-1). For all investigated materials, the values of the gamma index were found to be greater than 0.5 but less than 1, indicating that the gamma dose contribution from the studied building materials exceeds the exemption dose criterion of 0.3 mSv y(-1) but complies with the upper dose principle of 1 mSv y(-1).
Asaduzzaman, Khandoker; Mannan, Farhana; Khandaker, Mayeen Uddin; Farook, Mohideen Salihu; Elkezza, Aeman; Amin, Yusoff Bin Mohd; Sharma, Sailesh; Abu Kassim, Hasan Bin
2015-01-01
The concentrations of primordial radionuclides (226Ra, 232Th and 40K) in commonly used building materials (brick, cement and sand), the raw materials of cement and the by-products of coal-fired power plants (fly ash) collected from various manufacturers and suppliers in Bangladesh were determined via gamma-ray spectrometry using an HPGe detector. The results showed that the mean concentrations of 226Ra, 232Th and 40K in all studied samples slightly exceeded the typical world average values of 50 Bq kg−1, 50 Bq kg−1 and 500 Bq kg−1, respectively. The activity concentrations (especially 226Ra) of fly-ash-containing cement in this study were found to be higher than those of fly-ash-free cement. To evaluate the potential radiological risk to individuals associated with these building materials, various radiological hazard indicators were calculated. The radium equivalent activity values for all samples were found to be lower than the recommended limit for building materials of 370 Bq kg-1, with the exception of the fly ash. For most samples, the values of the alpha index and the radiological hazard (external and internal) indices were found to be within the safe limit of 1. The mean indoor absorbed dose rate was observed to be higher than the population-weighted world average of 84 nGy h–1, and the corresponding annual effective dose for most samples fell below the recommended upper dose limit of 1 mSv y–1. For all investigated materials, the values of the gamma index were found to be greater than 0.5 but less than 1, indicating that the gamma dose contribution from the studied building materials exceeds the exemption dose criterion of 0.3 mSv y-1 but complies with the upper dose principle of 1 mSv y−1. PMID:26473957
Assessment of environmental consequences of the normal operations of the ESS facility
NASA Astrophysics Data System (ADS)
Ene, D.; Avila, R.; Hjerpe, T.; Bugay, D.; Stenberg, K.
2018-06-01
As other accelerator based facilities, the European Spallation Source ESS facility will interact with the environment. The Swedish legislation requires a demonstration that the sum of the doses resulting from the exposure of any member of the public to ionizing radiation dose does not exceed the specified limit of 50 μSv/year. A radiological assessment has been produced to provide that demonstration. This evaluation was based upon the actual status of the ESS design. A graded approach was adopted through over the assessment allowing estimating dose for all radionuclides and exposure pathways, but the degree of detail in the assessment depend upon their relative radiological importance. The total dose was obtained making the sum of the contribution of all-important radionuclides treated realistically with that of all screened out radionuclides, derived by means a conservative method.
Automatic management system for dose parameters in interventional radiology and cardiology.
Ten, J I; Fernandez, J M; Vaño, E
2011-09-01
The purpose of this work was to develop an automatic management system to archive and analyse the major study parameters and patient doses for fluoroscopy guided procedures performed in cardiology and interventional radiology systems. The X-ray systems used for this trial have the capability to export at the end of the procedure and via e-mail the technical parameters of the study and the patient dose values. An application was developed to query and retrieve from a mail server, all study reports sent by the imaging modality and store them on a Microsoft SQL Server data base. The results from 3538 interventional study reports generated by 7 interventional systems were processed. In the case of some technical parameters and patient doses, alarms were added to receive malfunction alerts so as to immediately take appropriate corrective actions.
Ward, Rebecca; Carroll, William D; Cunningham, Paula; Ho, Sheng-Ang; Jones, Mary; Lenney, Warren; Thompson, David
2017-01-01
Objectives Cumulative radiation exposure is associated with increased risk of malignancy. This is important in cystic fibrosis (CF) as frequent imaging is required to monitor disease progression and diagnose complications. Previous estimates of cumulative radiation are outdated as the imaging was performed on older equipment likely to deliver higher radiation. Our objectives were to determine the radiation dose delivered to children during common radiological investigations using modern equipment and to identify the number of such investigations performed in a cohort of children with CF to calculate their cumulative radiation exposure. Design, setting and participants Data including age at investigation and radiation exposure measured as estimated effective dose (EED) were collected on 2827 radiological studies performed on children at one UK paediatric centre. These were combined with the details of all radiological investigations performed on 65 children with CF attending the same centre to enable calculation of each child’s cumulative radiation exposure. Results The mean EED for the common radiological investigations varied according to age. The range was 0.01–0.02 mSv for chest X-rays, 0.03–0.11 mSv for abdominal X-rays, 0.57–1.69 mSv for CT chest, 2.9–3.9 mSv for abdominal and pelvic CT, 0.20–0.21 mSv for sinus CT and 0.15–0.52 mSv for fluoroscopy-guided procedures. The mean EED was three to five times higher for helical compared with axial chest CT scans. The mean annual cumulative EED for our cohort of children with CF was 0.15 mSv/year with an estimated cumulative paediatric lifetime EED (0–18 years) of 3.5 mSv. Conclusions This study provides up-to-date estimations of the radiation exposure when using common radiological investigations. These doses and the estimates of cumulative radiation exposure in children with CF are lower than previously reported. This reflects the reduced EED associated with modern equipment and the use of age-specific scanning protocols. PMID:28827272
21 CFR 892.1360 - Radionuclide dose calibrator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radionuclide dose calibrator. 892.1360 Section 892.1360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1360 Radionuclide dose calibrator. (a...
[Radiological dose and metadata management].
Walz, M; Kolodziej, M; Madsack, B
2016-12-01
This article describes the features of management systems currently available in Germany for extraction, registration and evaluation of metadata from radiological examinations, particularly in the digital imaging and communications in medicine (DICOM) environment. In addition, the probable relevant developments in this area concerning radiation protection legislation, terminology, standardization and information technology are presented.
İnal, Tolga; Ataç, Gökçe
2014-01-01
PURPOSE We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. MATERIALS AND METHODS Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. RESULTS The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. CONCLUSION This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey. PMID:24317331
DOE Office of Scientific and Technical Information (OSTI.GOV)
Safari, M. J.; Wong, J. H. D.; Ng, K. H., E-mail: ngkh@um.edu.my
2015-05-15
Purpose: The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures. Methods: The calibration and reproducibility of the MOSkin detector and its dependency on different radiation beam qualitiesmore » were carried out using RQR standard radiation qualities in free-in-air geometry. Studies of the other characterization parameters, such as the dose linearity and dependency on exposure angle, field size, frame rate, depth-dose, and source-to-surface distance (SSD), were carried out using a solid water phantom under a clinical x-ray unit. Results: The MOSkin detector showed good reproducibility (94%) and dose linearity (99%) for the dose range of 2 to 213 cGy. The sensitivity did not significantly change with the variation of SSD (±1%), field size (±1%), frame rate (±3%), or beam energy (±5%). The detector angular dependence was within ±5% over 360° and the dose recorded by the MOSkin detector in different depths of a solid water phantom was in good agreement with the Markus parallel plate ionization chamber to within ±3%. Conclusions: The MOSkin detector proved to be reliable when exposed to different field sizes, SSDs, depths in solid water, dose rates, frame rates, and radiation incident angles within a clinical x-ray beam. The MOSkin detector with water equivalent depth equal to 0.07 mm is a suitable detector for in vivo skin dosimetry during interventional radiology procedures.« less
Safari, M J; Wong, J H D; Ng, K H; Jong, W L; Cutajar, D L; Rosenfeld, A B
2015-05-01
The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures. The calibration and reproducibility of the MOSkin detector and its dependency on different radiation beam qualities were carried out using RQR standard radiation qualities in free-in-air geometry. Studies of the other characterization parameters, such as the dose linearity and dependency on exposure angle, field size, frame rate, depth-dose, and source-to-surface distance (SSD), were carried out using a solid water phantom under a clinical x-ray unit. The MOSkin detector showed good reproducibility (94%) and dose linearity (99%) for the dose range of 2 to 213 cGy. The sensitivity did not significantly change with the variation of SSD (± 1%), field size (± 1%), frame rate (± 3%), or beam energy (± 5%). The detector angular dependence was within ± 5% over 360° and the dose recorded by the MOSkin detector in different depths of a solid water phantom was in good agreement with the Markus parallel plate ionization chamber to within ± 3%. The MOSkin detector proved to be reliable when exposed to different field sizes, SSDs, depths in solid water, dose rates, frame rates, and radiation incident angles within a clinical x-ray beam. The MOSkin detector with water equivalent depth equal to 0.07 mm is a suitable detector for in vivo skin dosimetry during interventional radiology procedures.
Manninen, A-L; Kotiaho, A; Nikkinen, J; Nieminen, M T
2015-04-01
This study aimed to validate a MOSFET dosemeter system for determining absorbed and effective doses (EDs) in the dose and energy range used in diagnostic radiology. Energy dependence, dose linearity and repeatability of the dosemeter were examined. The absorbed doses (ADs) were compared at anterior-posterior projection and the EDs were determined at posterior-anterior, anterior-posterior and lateral projections of thoracic imaging using an anthropomorphic phantom. The radiation exposures were made using digital radiography systems. This study revealed that the MOSFET system with high sensitivity bias supply set-up is sufficiently accurate for AD and ED determination. The dosemeter is recommended to be calibrated for energies <60 and >80 kVp. The entrance skin dose level should be at least 5 mGy to minimise the deviation of the individual dosemeter dose. For ED determination, dosemeters should be implanted perpendicular to the surface of the phantom to prevent the angular dependence error. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Radiological environment within an NPP after a severe nuclear accident
NASA Astrophysics Data System (ADS)
Andgren, Karin; Fritioff, Karin; Buhr, Anna Maria Blixt; Huutoniemi, Tommi
2017-09-01
The radiological environment following a severe nuclear accident can be visualised on building layouts. The direct radiation in an area (or room) can be visualized on the layout by a colouring scheme depending on the dose rate level (for example orange for high gamma dose rate level and purple for an intermediate gamma dose rate level). Following the Fukushima accident, a need for update of these layouts has been identified at the Swedish nuclear power plant of Forsmark. Shielding calculations for areas where access is desired for severe accident management have been performed. Many different sources of radiation together with different types of shielding material contribute to the dose that would be received by a person entering the area. External radiation from radioactivity within e.g. pipes and components is considered and also external radiation from radioactivity in the air (originating from diffuse leakage of the containment atmosphere). Results are presented as dose rates for relevant dose points together with a method for estimating the dose rate levels for each of the rooms of the reactor building.
Carpeggiani, Clara; Paterni, Marco; Caramella, Davide; Vano, Eliseo; Semelka, Richard C; Picano, Eugenio
2012-11-01
Awareness of radiological risk is low among doctors and patients. An educational/decision tool that considers each patient' s cumulative lifetime radiation exposure would facilitate provider-patient communication. The purpose of this work was to develop user-friendly software for simple estimation and communication of radiological risk to patients and doctors as a part of the SUIT-Heart (Stop Useless Imaging Testing in Heart disease) Project of the Tuscany Region. We developed a novel software program (PC-platform, Windows OS fully downloadable at http://suit-heart.ifc.cnr.it) considering reference dose estimates from American Heart Association Radiological Imaging 2009 guidelines and UK Royal College of Radiology 2007 guidelines. Cancer age and gender-weighted risk were derived from Biological Effects of Ionising Radiation VII Committee, 2006. With simple input functions (demographics, age, gender) the user selects from a predetermined menu variables relating to natural (e.g., airplane flights and geo-tracked background exposure), professional (e.g., cath lab workers) and medical (e.g., CT, cardiac scintigraphy, coronary stenting) sources. The program provides a simple numeric (cumulative effective dose in milliSievert, mSv, and equivalent number of chest X-rays) and graphic (cumulative temporal trends of exposure, cancer cases out of 100 exposed persons) display. A simple software program allows straightforward estimation of cumulative dose (in multiples of chest X-rays) and risk (in extra % lifetime cancer risk), with simple numbers quantifying lifetime extra cancer risk. Pictorial display of radiation risk may be valuable for increasing radiological awareness in cardiologists. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Efficiency of personal dosimetry methods in vascular interventional radiology.
Bacchim Neto, Fernando Antonio; Alves, Allan Felipe Fattori; Mascarenhas, Yvone Maria; Giacomini, Guilherme; Maués, Nadine Helena Pelegrino Bastos; Nicolucci, Patrícia; de Freitas, Carlos Clayton Macedo; Alvarez, Matheus; Pina, Diana Rodrigues de
2017-05-01
The aim of the present study was to determine the efficiency of six methods for calculate the effective dose (E) that is received by health professionals during vascular interventional procedures. We evaluated the efficiency of six methods that are currently used to estimate professionals' E, based on national and international recommendations for interventional radiology. Equivalent doses on the head, neck, chest, abdomen, feet, and hands of seven professionals were monitored during 50 vascular interventional radiology procedures. Professionals' E was calculated for each procedure according to six methods that are commonly employed internationally. To determine the best method, a more efficient E calculation method was used to determine the reference value (reference E) for comparison. The highest equivalent dose were found for the hands (0.34±0.93mSv). The two methods that are described by Brazilian regulations overestimated E by approximately 100% and 200%. The more efficient method was the one that is recommended by the United States National Council on Radiological Protection and Measurements (NCRP). The mean and median differences of this method relative to reference E were close to 0%, and its standard deviation was the lowest among the six methods. The present study showed that the most precise method was the one that is recommended by the NCRP, which uses two dosimeters (one over and one under protective aprons). The use of methods that employ at least two dosimeters are more efficient and provide better information regarding estimates of E and doses for shielded and unshielded regions. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
1999-01-01
This report provides guidance on the application of the ICRP system of radiological protection to prolonged exposure situations affecting members of the public. It addresses the general application of the Commission's system to the control of prolonged exposures resulting from practices and to the undertaking of interventions in prolonged exposure situations. Additionally, it provides recommendations on generic reference levels for such interventions. The report also considers some specific situations and discusses a number of issues that have been of concern, namely: natural radiation sources that may give rise to high doses; the restoration and rehabilitation of sites where human activities involving radioactive substances have been carried out; the return to 'normality' following an accident that has released radioactive substances to the environment; and the global marketing of commodities for public consumption that contain radioactive substances. Annexes provide some examples of prolonged exposure situations and discuss the radiological protection quantities, radiation-induced health effects and aspects of the Commission's system of radiological protection relevant to prolonged exposure. Quantitative recommendations for prolonged exposures are provided in the report. They must be interpreted with extreme caution; Chapters 4 and 5 stress the upper bound nature of the following values: Generic reference levels for intervention, in terms of existing total annual doses, are given as < approximately 100 mSv, above which intervention is almost always justifiable (situations for which the annual dose threshold for deterministic effects in relevant organs is exceeded will almost always require intervention), and < approximately 10 mSv, below which intervention is not likely to be justifiable (and above which it may be necessary). Intervention exemption levels for commodities, especially building materials, are expressed as an additional annual dose of approximately 1 mSv. The dose limit for exposures of the public from practices is expressed as aggregated (prolonged and transitory) additional annual doses from all relevant practices of 1 mSv. Dose constraints for sources within practices are expressed as an additional annual dose lower than 1 mSv (e.g. of approximately 0.3 mSv), which could be approximately 0.1 mSv for the prolonged exposure component. An exemption level for practices is expressed as an additional annual dose of approximately 0.01 mSv.
Radiological impact of 2016 operations at the Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minter, K. L.; Jannik, G. T.; Dixon, K. M.
This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2016 Savannah River Site (SRS) air and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios, such as the consumption of wildlife or goat milk.
Environmental monitoring in interventional radiology
NASA Astrophysics Data System (ADS)
Del Sol, S.; Garcia, R.; Sánchez-Guzmán, D.; Ramirez, G.; Chavarin, E. U.; Rivera, T.
2017-01-01
The procedures in Interventional Radiology involve long times of exposure and high number of radiographic images that bring higher radiation doses to patients, staff and environmental than those received in conventional Radiology. Currently for monitoring the dose, the thermoluminescent dosimetry use is recommended. The aim of this work was to carry out the monitoring of the environmental scattered radiation inside the IR room using two types of thermoluminescent dosimeters, TLD-100 (reference dosimeter), CaSO4:Dy (synthesized in our laboratory). The results indicate that the TLD-100 is not effective for the environmental monitoring of low-energy Rx rooms. The CaSO4:Dy presented good behaviour over the 6 months of study. The results will be specific to each room so it is recommended such studies as part of the program of quality control of each Rx room.
Assessment of Dose to the Nursing Infant from Radionuclides in Breast Milk
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leggett, Richard Wayne; Eckerman, Keith F
A computer software package was developed to predict tissue doses to an infant due to intake of radionuclides in breast milk based on bioassay measurements and exposure data for the mother. The package is intended mainly to aid in decisions regarding the safety of breast feeding by a mother who has been acutely exposed to a radionuclide during lactation or pregnancy, but it may be applied to previous intakes during the mother s adult life. The package includes biokinetic and dosimetric information needed to address intake of Co-60, Sr-90, Cs-134, Cs-137, Ir-192, Pu-238, Pu-239, Am-241, or Cf-252 by the mother.more » It has been designed so that the library of biokinetic and dosimetric files can be expanded to address a more comprehensive set of radionuclides without modifying the basic computational module. The methods and models build on the approach used in Publication 95 of the International Commission on Radiological Protection (ICRP 2004), Doses to Infants from Ingestion of Radionuclides in Mothers Milk . The software package allows input of case-specific information or judgments such as chemical form or particle size of an inhaled aerosol. The package is expected to be more suitable than ICRP Publication 95 for dose assessment for real events or realistic planning scenarios in which measurements of the mother s excretion or body burden are available.« less
Fernandez-Soto, J M; Ten, J I; Sanchez, R M; España, M; Pifarre, X; Vano, E
2015-07-01
The purpose of this article is to present the results of connecting the interventional radiology and cardiology laboratories of five university hospitals to a unique server using an automatic patient dose registry system (Dose On Line for Interventional Radiology, DOLIR) developed in-house, and to evaluate its feasibility more than a year after its introduction. The system receives and stores demographic and dosimetric parameters included in the MPPS DICOM objects sent by the modalities to a database. A web service provides a graphical interface to analyse the information received. During 2013, the system processed 10 788 procedures (6874 cardiac, 2906 vascular and 1008 neuro interventional). The percentages of patients requiring clinical follow-up due to potential tissue reactions before and after the use of DOLIR are presented. The system allowed users to verify in real-time, if diagnostic (or interventional) reference levels are fulfilled. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Negrone, Mario; Di Lascio, Doriana
2016-01-01
The new recommended equivalent (publication n. 118 of International Commission on Radiological Protection) dose limit for occupational exposure of the lens of the eye is based on prevention of radiogenic cataracts, with the underlying assumption of a nominal threshold which has been adjusted from 2,5 Gy to 0.5 Gy for acute or protracted exposure. The study aim was to determine the prevalence of ocular lens opacity among healthcare workers (radiologic technologists, physicians, physician assistants) with respect to occupational exposures to ionizing radiations. Therefore, we conducted another retrospective study to explore the relationship between occupational exposure to radiation and opacity lens increase. Healthcare data (current occupational dosimetry, occupational history) are used to investigate risk of increase of opacity lens of eye. The sample of this study consisted of 148 health-workers (64 M and 84 W) aged from 28 to 66 years coming from different hospitals of the ASL of Potenza (clinic, hospital and institute with scientific feature). On the basis of the evaluation of the dosimetric history of the workers (global and effective dose) we agreed to ascribe the group of exposed subjects in cat A (equivalent dose > 2 mSV) and the group of non exposed subjects in cat B (workers with annual absorbed level of dose near 0 mSv). The analisys was conducted using SPSS 15.0 (Statistical Package for Social Science). A trend of increased ocular lens opacity was found with increasing number for workers in highest category of exposure (cat. A, Yates' chi-squared test = 13,7 p = 0,0002); variable significantly related to opacity lens results job: nurse (Χ(2)Y = 14,3 p = 0,0002) physician (Χ(2)Y = 2.2 p = 0,1360) and radiologic technologists (Χ(2)Y = 0,1 p = 0,6691). In conclusion our provides evidence that exposure to relatively low doses of ionizing radiation may be harmful to the lens of the eye and may increase a long-term risk of cataract formation; similary necessary to monitor the "equivalent dose" for the lens for the workers in highest category of exposure.
MO-DE-204-00: International Symposium: Patient Dose Reduction in Diagnostic Radiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2016-06-15
The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented.more » Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the global trend in the dose optimization and future prospectives. M. Rehani, The work was a part of the work of IAEA where I was an employee and IAEA is a United Nations organization.« less
MO-DE-204-03: Radiology Dose Optimisation - An Australian Perspective
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schick, D.
2016-06-15
The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented.more » Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the global trend in the dose optimization and future prospectives. M. Rehani, The work was a part of the work of IAEA where I was an employee and IAEA is a United Nations organization.« less
Reconstructive dosimetry for cutaneous radiation syndrome
Lima, C.M.A.; Lima, A.R.; Degenhardt, Ä.L.; Valverde, N.J.; Da Silva, F.C.A.
2015-01-01
According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry. PMID:26445332
Öğretici, Akın; Çakır, Aydın; Akbaş, Uğur; Köksal, Canan; Kalafat, Ümmühan; Tambaş, Makbule; Bilge, Hatice
2017-01-01
Purpose: This study aims to investigate the factors that reduce fetal dose in pregnant patients with breast cancer throughout their radiation treatment. Two main factors in a standard radiation oncology center are considered as the treatment planning systems (TPSs) and simple shielding for intensity modulated radiation therapy technique. Materials and Methods: TPS factor was evaluated with two different planning algorithms: Anisotropic analytical algorithm and Acuros XB (external beam). To evaluate the shielding factor, a standard radiological purpose lead apron was chosen. For both studies, thermoluminescence dosimeters were used to measure the point dose, and an Alderson RANDO-phantom was used to simulate a female pregnant patient in this study. Thirteen measurement points were chosen in the 32nd slice of the phantom to cover all possible locations of a fetus up to 8th week of gestation. Results: The results show that both of the TPS algorithms are incapable of calculating the fetal doses, therefore, unable to reduce them at the planning stage. Shielding with a standard lead apron, however, showed a slight radiation protection (about 4.7%) to the fetus decreasing the mean fetal dose from 84.8 mGy to 80.8 mGy, which cannot be disregarded in case of fetal irradiation. Conclusions: Using a lead apron for shielding the abdominal region of a pregnant patient during breast irradiation showed a minor advantage; however, its possible side effects (i.e., increased scattered radiation and skin dose) should also be investigated further to solidify its benefits. PMID:28974857
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mueller, J.H.
The possible necessity of therapeutic abortion following diagnostic or therapeutic radiologic procedures in women during the first trimester of pregnancy is discussed, with emphasis on the minimal fetal dose for recommendation of abortion. A discussion by nine participants is presented. It is concluded that radioinduced genetic injury of the mother is not sufficient reason for abortion, but that such intervention may be necessary if a fetal dose of 10 r is exceeded during the first two months of pregnancy. At later stages of pregnancy the acceptable dose does not exceed 25 r. However, radiodiagnostic procedures in the last trimester ofmore » pregnancy are not considered a hazard to the fetus. The importance of avoiding any radiation exposure of women during the last half of the menstrual cycle is emphasized. Some dosimetric data are presented showing the fetal-body, fetal-gonad, and maternal-gonad doses received during various abdominal radiologic procedures and with x rays of different kilovoltages. (BBB)« less
INTEGRATED CIRCUITS FROM MOBILE PHONES AS POSSIBLE EMERGENCY OSL/TL DOSIMETERS.
Sholom, S; McKeever, S W S
2016-09-01
In this article, optically stimulated luminescence (OSL) data are presented from integrated circuits (ICs) extracted from mobile phones. The purpose is to evaluate the potential of using OSL from components in personal electronic devices such as smart phones as a means of emergency dosimetry in the event of a large-scale radiological incident. ICs were extracted from five different makes and models of mobile phone. Sample preparation procedures are described, and OSL from the IC samples following irradiation using a (90)Sr/(90)Y source is presented. Repeatability, sensitivity, dose responses, minimum measureable doses, stability and fading data were examined and are described. A protocol for measuring absorbed dose is presented, and it was concluded that OSL from these components is a viable method for assessing dose in the days following a radiological incident. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Assessment of eye lens doses for workers during interventional radiology procedures.
Urboniene, A; Sadzeviciene, E; Ziliukas, J
2015-07-01
The assessment of eye lens doses for workers during interventional radiology (IR) procedures was performed using a new eye lens dosemeter. In parallel, the results of routine individual monitoring were analysed and compared with the results obtained from measurements with a new eye lens dosemeter. The eye lens doses were assessed using Hp(3) measured at the level of the eyes and were compared with Hp(10) measured with the whole-body dosemeter above the lead collar. The information about use of protective measures, the number of performed interventional procedures per month and their fluoroscopy time was also collected. The assessment of doses to the lens of the eye was done for 50 IR workers at 9 Lithuanian hospitals for the period of 2012-2013. If the use of lead glasses is not taken into account, the estimated maximum annual dose equivalent to the lens of the eye was 82 mSv. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Gusev, B I; Abylkassimova, Z N; Apsalikov, K N
1997-09-01
As a result of atmospheric nuclear tests at the Semipalatinsk test site 'Polygon', adjacent territories were contaminated by radionuclide fallout. The population of some districts in the Semipalatinsk oblast were exposed to elevated levels of radiation. Contamination and exposure mostly resulted from early atmospheric tests. The radiological situation of the Semipalatinsk oblast is described. Effective dose estimates due to external and internal exposure attributable to the 1949 and 1953 tests in villages near the Polygon range from 70 mSv to 4470 mSv.
PROBLEMS OF RADIOLOGICAL PROTECTION IN FLAW DETECTION (in Polish)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Domanus, J.; Wolski, M.
1962-01-01
All industrial flaw detection laboratories are covered, with respect to their radiological protection, by the supervision of the Inst. of Electrotechnics. A discussion is given of the results of this action, especially the cases of exceeding the admissible doses. The analysis of endangerment by radiation of employees of flaw detection laboratories is given. (auth)
El-Bahi, S M; Sroor, A; Mohamed, Gehan Y; El-Gendy, N S
2017-05-01
In this study, the activity concentrations of the natural radionuclides in phosphate rocks and its products were measured using a high- purity germanium detector (HPGe). The obtained activity results show remarkable wide variation in the radioactive contents for the different phosphate samples. The average activity concentration of 235 U, 238 U, 226 Ra, 232 Th and 40 K was found as (45, 1031, 786, 85 and 765Bq/kg) for phosphate rocks, (28, 1234, 457, 123 and 819Bq/kg) for phosphate fertilizers, (47, 663, 550, 79 and 870Bq/kg) for phosphogypsum and (25, 543, 409, 54 and 897Bq/kg) for single super phosphate respectively. Based on the measured activities, the radiological parameters (activity concentration index, absorbed gamma dose rate in outdoor and indoor and the corresponding annual effective dose rates and total excess lifetime cancer risk) were estimated to assess the radiological hazards. The total excess lifetime cancer risk (ELCR) has been calculated and found to be high in all samples, which related to high radioactivity, representing radiological risk for the health of the population. Copyright © 2017 Elsevier Ltd. All rights reserved.
1981-04-28
on initial doses. Residual doses are determined through an automiated procedure that utilizes raw data in regression analyses to fit space-time models...show their relationship to the observer positions. The computer-calculated doses do not reflect the presence of the human body in the radiological
[Radiation protection in interventional radiology].
Adamus, R; Loose, R; Wucherer, M; Uder, M; Galster, M
2016-03-01
The application of ionizing radiation in medicine seems to be a safe procedure for patients as well as for occupational exposition to personnel. The developments in interventional radiology with fluoroscopy and dose-intensive interventions require intensified radiation protection. It is recommended that all available tools should be used for this purpose. Besides the options for instruments, x‑ray protection at the intervention table must be intensively practiced with lead aprons and mounted lead glass. A special focus on eye protection to prevent cataracts is also recommended. The development of cataracts might no longer be deterministic, as confirmed by new data; therefore, the International Commission on Radiological Protection (ICRP) has lowered the threshold dose value for eyes from 150 mSv/year to 20 mSv/year. Measurements show that the new values can be achieved by applying all X‑ray protection measures plus lead-containing eyeglasses.
Radiological operational scenario for a permanent lunar base
NASA Astrophysics Data System (ADS)
McCormack, Percival D.
An operational scenario for a lunar base is postulated based on 30 lunar base personnel and 2 year tours of duty plus stipulated numbers of EVA's and sorties in the lunar rover vehicles. It is also postulated that the main shielding material for the lunar base units (habitats, laboratories, etc.) will be lunar regolith. Using the solar minimum period as the basis, total accumulated dose equivalents for the galactic cosmic radiation over the two year period are computed at various shielding depths. Depths of regolith of over 20 g/sq cm are sufficient to reduce the total dose equivalents to well under the present limits. The second arm of the radiological health strategy -- continuous and all-encompassing radiation dosimetry -- is also discussed in some detail. It is also emphasized that monitoring of the base personnel for genetic mutations and chromosomal aberrations must be part of the radiological health program in the lunar base.
Radiological risks from irradiation of cargo contents with EURITRACK neutron inspection systems
NASA Astrophysics Data System (ADS)
Giroletti, E.; Bonomi, G.; Donzella, A.; Viesti, G.; Zenoni, A.
2012-07-01
The radiological risk for the population related to the neutron irradiation of cargo containers with a tagged neutron inspection system has been studied. Two possible effects on the public health have been assessed: the modification of the nutritional and organoleptic properties of the irradiated materials, in particular foodstuff, and the neutron activation of consumer products (i.e. food and pharmaceuticals). The result of this study is that irradiation of food and foodstuff, pharmaceutical and medical devices in container cargoes would neither modify the properties of the irradiated material nor produce effective doses of concern for public health. Furthermore, the dose received by possible stowaways present inside the container during the inspection is less than the annual effective dose limit defined by European Legislation for the public.
Yee, Micaela V; Barron, Rochelle A; Knobloch, Tom A; Pandey, Umesh; Twyford, Catherine; Freebairn, Ross C
2012-08-01
To describe the cumulative effective dose of radiation that was received during the initial Emergency Department assessment and ICU stay of patients admitted with trauma, who required mechanical ventilation, during two time periods. A retrospective analysis of radiological and clinical data, set in a regional nonurban ICU. Two cohorts (starting 1 January 2004 and 1 January 2009), each comprising 45 adult patients admitted with trauma who were mechanically ventilated in intensive care, were studied. Frequency and type of radiological examinations, demographic information, and clinical data were collated from the radiological database, hospital admission record and Australian Outcomes Research Tool for Intensive Care database. Cumulative effective doses were calculated and expressed as a total dose and average daily dose for each cohort. The median cumulative effective dose per patient (in milliSieverts) increased from 34.59 [interquartile range (IQR) 9.08-43.91] in 2004 to 40.51 (IQR 22.01-48.87) in 2009, P=0.045. An increased number of computed tomography examinations per patient was also observed over the same interval from an average of 2.11 (median 2, IQR 1-3) in 2004 to an average of 2.62 (2, 2-4) in 2009, P=0.046. The radiation exposure of mechanically ventilated trauma patients in intensive care has increased over time. Radiation exposure should be prospectively monitored and staff should be aware of the increased risk resulting from this change in practice.
Teaching Primary Health Care: An Interdisciplinary Approach.
ERIC Educational Resources Information Center
Bezzina, Paul; Keogh, Johann J.; Keogh, Mariana
1998-01-01
Nursing and radiology students (n=15) at the University of Malta who completed an interdisciplinary module on primary health care reported they found the theoretical material applicable to practice; the module enabled them to learn about their potential role in primary health care. (SK)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeremy Gwin and Douglas Frenette
This document contains process knowledge and radiological data and analysis to support approval for release of the 25-ton locomotive, Serial Number 21547, at the Area 25 Engine Maintenance, Assembly, and Disassembly (EMAD) Facility, located on the Nevada Test Site (NTS). The 25-ton locomotive is a small, one-of-a-kind locomotive used to move railcars in support of the Nuclear Engine for Rocket Vehicle Application project. This locomotive was identified as having significant historical value by the Nevada State Railroad Museum in Boulder City, Nevada, where it will be used as a display piece. A substantial effort to characterize the radiological conditions ofmore » the locomotive was undertaken by the NTS Management and Operations Contractor, National Security Technologies, LLC (NSTec). During this characterization process, seven small areas on the locomotive had contamination levels that exceeded the NTS release criteria (limits consistent with U.S. Department of Energy [DOE] Order DOE O 5400.5, “Radiation Protection of the Public and the Environment”). The decision was made to perform radiological decontamination of these known accessible impacted areas to further the release process. On February 9, 2010, NSTec personnel completed decontamination of these seven areas to within the NTS release criteria. Although all accessible areas of the locomotive had been successfully decontaminated to within NTS release criteria, it was plausible that inaccessible areas of the locomotive (i.e., those areas on the locomotive where it was not possible to perform radiological surveys) could potentially have contamination above unrestricted release limits. To access the majority of these inaccessible areas, the locomotive would have to be disassembled. A complete disassembly for a full radiological survey could have permanently destroyed parts and would have ruined the historical value of the locomotive. Complete disassembly would also add an unreasonable financial burden for the contractor. A decision was reached between the NTS regulator and NSTec, opting for alternative authorized limits from DOE Headquarters. In doing so, NSTec personnel performed a dose model using the DOE-approved modeling code RESRAD-BUILD v3.5 to evaluate scenarios. The parameters used in the dose model were conservative. NSTec’s Radiological Engineering Calculation, REC-2010-001, “Public Dose Estimate from the EMAD 25 Ton Locomotive,” concluded that the four scenarios evaluated were below the 25-millirem per year limit, the “likely” dose scenarios met the “few millirem in a year” criteria, and that the EMAD 25-ton locomotive met the radiological requirements to be released with residual radioactivity to the public.« less
Radiological protection issues arising during and after the Fukushima nuclear reactor accident.
González, Abel J; Akashi, Makoto; Boice, John D; Chino, Masamichi; Homma, Toshimitsu; Ishigure, Nobuhito; Kai, Michiaki; Kusumi, Shizuyo; Lee, Jai-Ki; Menzel, Hans-Georg; Niwa, Ohtsura; Sakai, Kazuo; Weiss, Wolfgang; Yamashita, Shunichi; Yonekura, Yoshiharu
2013-09-01
Following the Fukushima accident, the International Commission on Radiological Protection (ICRP) convened a task group to compile lessons learned from the nuclear reactor accident at the Fukushima Daiichi nuclear power plant in Japan, with respect to the ICRP system of radiological protection. In this memorandum the members of the task group express their personal views on issues arising during and after the accident, without explicit endorsement of or approval by the ICRP. While the affected people were largely protected against radiation exposure and no one incurred a lethal dose of radiation (or a dose sufficiently large to cause radiation sickness), many radiological protection questions were raised. The following issues were identified: inferring radiation risks (and the misunderstanding of nominal risk coefficients); attributing radiation effects from low dose exposures; quantifying radiation exposure; assessing the importance of internal exposures; managing emergency crises; protecting rescuers and volunteers; responding with medical aid; justifying necessary but disruptive protective actions; transiting from an emergency to an existing situation; rehabilitating evacuated areas; restricting individual doses of members of the public; caring for infants and children; categorising public exposures due to an accident; considering pregnant women and their foetuses and embryos; monitoring public protection; dealing with 'contamination' of territories, rubble and residues and consumer products; recognising the importance of psychological consequences; and fostering the sharing of information. Relevant ICRP Recommendations were scrutinised, lessons were collected and suggestions were compiled. It was concluded that the radiological protection community has an ethical duty to learn from the lessons of Fukushima and resolve any identified challenges. Before another large accident occurs, it should be ensured that inter alia: radiation risk coefficients of potential health effects are properly interpreted; the limitations of epidemiological studies for attributing radiation effects following low exposures are understood; any confusion on protection quantities and units is resolved; the potential hazard from the intake of radionuclides into the body is elucidated; rescuers and volunteers are protected with an ad hoc system; clear recommendations on crisis management and medical care and on recovery and rehabilitation are available; recommendations on public protection levels (including infant, children and pregnant women and their expected offspring) and associated issues are consistent and understandable; updated recommendations on public monitoring policy are available; acceptable (or tolerable) 'contamination' levels are clearly stated and defined; strategies for mitigating the serious psychological consequences arising from radiological accidents are sought; and, last but not least, failures in fostering information sharing on radiological protection policy after an accident need to be addressed with recommendations to minimise such lapses in communication.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ebinger, M.H.; Beckman, R.J.; Myers, O.B.
1996-09-01
The purpose of this study was to evaluate the immediate and long-term consequences of depleted uranium (DU) in the environment at Aberdeen Proving Ground (APG) and Yuma Proving Ground (YPG) for the Test and Evaluation Command (TECOM) of the US Army. Specifically, we examined the potential for adverse radiological and toxicological effects to humans and ecosystems caused by exposure to DU at both installations. We developed contaminant transport models of aquatic and terrestrial ecosystems at APG and terrestrial ecosystems at YPG to assess potential adverse effects from DU exposure. Sensitivity and uncertainty analyses of the initial models showed the portionsmore » of the models that most influenced predicted DU concentrations, and the results of the sensitivity analyses were fundamental tools in designing field sampling campaigns at both installations. Results of uranium (U) isotope analyses of field samples provided data to evaluate the source of U in the environment and the toxicological and radiological doses to different ecosystem components and to humans. Probabilistic doses were estimated from the field data, and DU was identified in several components of the food chain at APG and YPG. Dose estimates from APG data indicated that U or DU uptake was insufficient to cause adverse toxicological or radiological effects. Dose estimates from YPG data indicated that U or DU uptake is insufficient to cause radiological effects in ecosystem components or in humans, but toxicological effects in small mammals (e.g., kangaroo rats and pocket mice) may occur from U or DU ingestion. The results of this study were used to modify environmental radiation monitoring plans at APG and YPG to ensure collection of adequate data for ongoing ecological and human health risk assessments.« less
Kulkarni, S; Johnson, P C D; Kettles, S; Kasthuri, R S
2012-01-01
Objective : To assess the effects of playing patient-selected music during interventional procedures on (1) the doses of sedation and analgesia and (2) anxiety levels. Methods : Patients undergoing interventional radiological procedures were randomised to either the intervention (music) or the control (no music) group. Patients in the intervention group had music of their choice played via headphones during the procedure. The primary outcomes were reductions in the doses of drugs for sedation (midazolam) and analgesia (fentanyl). Anxiety levels were assessed both before and after the procedure using the validated State Anxiety Inventory. Mean pulse rate and average of mean blood pressures were also recorded before and during the procedures as surrogate indicators of anxiety levels. Results : 100 patients were randomised in a 1:1 ratio. There were 58 males and 42 females, with a mean age of 58 years. Sedation was required in 21 (42%) patients in the music group compared with 30 (60%) patients in the control group (p=0.046). The mean [standard deviation (SD)] midazolam dose was 2.1 mg (2.3 mg) in the control group and 1.3 mg (2.2 mg) in the music group (p=0.027). The mean (SD) fentanyl dose was 29 mg (40 mg) in the control group and 18 mg (34 mg) in the music group (p=0.055). There was no significant effect of music on the change from baseline in anxiety levels (p=0.74), pulse rate (p=0.56) or blood pressure (p=0.34). Conclusion : Sedation requirements are significantly reduced by playing self-selected music to the patient during interventional radiology procedures. By lowering sedation during interventional radiology, music makes the procedure safer. It also contributes favourably to the overall patient experience. PMID:22422386
SU-E-I-33: Establishment of CT Diagnostic Reference Levels in Province Nova Scotia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tonkopi, E; Abdolell, M; Duffy, S
2015-06-15
Purpose: To evaluate patient radiation dose from the most frequently performed CT examinations and to establish provincial diagnostic reference levels (DRLs) as a tool for protocol optimization. Methods: The study investigated the following CT examinations: head, chest, abdomen/pelvis, and chest/abdomen/pelvis (CAP). Dose data, volume CT dose index (CTDIvol) and dose-length product (DLP), were collected from 15 CT scanners installed during 2004–2014 in 11 hospital sites of Nova Scotia. All scanners had dose modulation options and multislice capability (16–128 detector rows). The sample for each protocol included 15 average size patients (70±20 kg). Provincial DRLs were calculated as the 75th percentilemore » of patient dose distributions. The differences in dose between hospitals were evaluated with a single factor ANOVA statistical test. Generalized linear modeling was used to determine the factors associated with higher radiation dose. A sample of 36 abdominal studies performed on three different scanners was blinded and randomized for an assessment by an experienced radiologist who graded the imaging quality of anatomic structures. Results: Data for 900 patients were collected. The DRLs were proposed using CTDIvol (mGy) and DLP (mGy*cm) values for CT head (67 and 1049, respectively), chest (12 and 393), abdomen/pelvis (16 and 717), and CAP (14 and 1034). These DRLs were lower than the published national data except for the head CTDIvol. The differences between the means of the dose distributions from each scanner were statistically significant (p<0.05) for all examinations. A very weak correlation was found between the dose and the scanner age or the number of slices with Pearson’s correlation coefficients of 0.011–0.315. The blinded analysis of image quality demonstrated no clinically significant difference except for the noise category. Conclusion: Provincial DRLs were established for typical CT examinations. The variations in dose between the hospitals suggested a large potential for optimization of examinations. Radiology Research Foundation grant.« less
Technology Assessment and Roadmap for the Emergency Radiation Dose Assessment Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turteltaub, K W; Hartman-Siantar, C; Easterly, C
2005-10-03
A Joint Interagency Working Group (JIWG) under the auspices of the Department of Homeland Security Office of Research and Development conducted a technology assessment of emergency radiological dose assessment capabilities as part of the overall need for rapid emergency medical response in the event of a radiological terrorist event in the United States. The goal of the evaluation is to identify gaps and recommend general research and development needs to better prepare the Country for mitigating the effects of such an event. Given the capabilities and roles for responding to a radiological event extend across many agencies, a consensus ofmore » gaps and suggested development plans was a major goal of this evaluation and road-mapping effort. The working group consisted of experts representing the Departments of Homeland Security, Health and Human Services (Centers for Disease Control and the National Institutes of Health), Food and Drug Administration, Department of Defense and the Department of Energy's National Laboratories (see appendix A for participants). The specific goals of this Technology Assessment and Roadmap were to: (1) Describe the general context for deployment of emergency radiation dose assessment tools following terrorist use of a radiological or nuclear device; (2) Assess current and emerging dose assessment technologies; and (3) Put forward a consensus high-level technology roadmap for interagency research and development in this area. This report provides a summary of the consensus of needs, gaps and recommendations for a research program in the area of radiation dosimetry for early response, followed by a summary of the technologies available and on the near-term horizon. We then present a roadmap for a research program to bring present and emerging near-term technologies to bear on the gaps in radiation dose assessment and triage. Finally we present detailed supporting discussion on the nature of the threats we considered, the status of technology today, promising emerging technologies and references for further reading.« less
Richardson, Richard B
2009-06-01
The factors that influence the dose and risk to vulnerable population groups from exposure and internal uptake of chemicals are examined and, in particular, the radionuclides released in chemical, biological, radiological, nuclear and explosive events. The paper seeks to identify the areas that would benefit from further research. The intake and body burdens of carbon and calcium were assessed as surrogates for contaminants that either act like or bind to hydrocarbons (e.g. tritium and (14)C) or bone-seeking radionuclides (e.g. (90)Sr and (239)Pu). The shortest turnover times for such materials in the whole body were evaluated for the newborn: 11 d and 0.5 y for carbon and calcium, respectively. However, their biokinetic behaviour is complicated by a particularly high percentage of the gut-absorbed dietary intake of carbon (approximately 16%) and calcium (approximately 100%) that is incorporated into the soft tissue and skeleton of the growing neonate. The International Commission on Radiological Protection dose coefficients (Sv Bq(-1)) were examined for 14 radionuclides, including 9 of concern because of their potential use in radiological dispersal devices. The dose coefficients for a 3-month-old are greater than those for adults (2-56 times more for ingestion and 2-12 times for inhalation). The age-dependent dose and exposure assessment of contaminant intakes would improve by accounting for gender and growth where it is currently neglected. Health risk is evaluated as the product of the exposure and hazard factors, the latter being about 10-fold greater in infants than in adults. The exposure factor is also approximately 10-fold higher for ingestion by infants than by adults, and unity for inhalation varying with the contaminant. Qualitative and quantitative physiological and epidemiological evidence supports infants being more vulnerable to cancer and neurological deficit than older children.
The Northern Marshall Islands Radiological Survey: data and dose assessments.
Robison, W L; Noshkin, V E; Conrado, C L; Eagle, R J; Brunk, J L; Jokela, T A; Mount, M E; Phillips, W A; Stoker, A C; Stuart, M L; Wong, K M
1997-07-01
Fallout from atmospheric nuclear tests, especially from those conducted at the Pacific Proving Grounds between 1946 and 1958, contaminated areas of the Northern Marshall Islands. A radiological survey at some Northern Marshall Islands was conducted from September through November 1978 to evaluate the extent of residual radioactive contamination. The atolls included in the Northern Marshall Islands Radiological Survey (NMIRS) were Likiep, Ailuk, Utirik, Wotho, Ujelang, Taka, Rongelap, Rongerik, Bikar, Ailinginae, and Mejit and Jemo Islands. The original test sites, Bikini and Enewetak Atolls, were also visited on the survey. An aerial survey was conducted to determine the external gamma exposure rate. Terrestrial (soil, food crops, animals, and native vegetation), cistern and well water samples, and marine (sediment, seawater, fish and clams) samples were collected to evaluate radionuclide concentrations in the atoll environment. Samples were processed and analyzed for 137Cs, 90Sr, 239+240Pu and 241Am. The dose from the ingestion pathway was calculated using the radionuclide concentration data and a diet model for local food, marine, and water consumption. The ingestion pathway contributes 70% to 90% of the estimated dose. Approximately 95% of the dose is from 137Cs. 90Sr is the second most significant radionuclide via ingestion. External gamma exposure from 137Cs accounts for about 10% to 30% of the dose. 239+240Pu and 241Am are the major contributors to dose via the inhalation pathway; however, inhalation accounts for only about 1% of the total estimated dose, based on surface soil levels and resuspension studies. All doses are computed for concentrations decay corrected to 1996. The maximum annual effective dose from manmade radionuclides at these atolls ranges from .02 mSv y(-1) to 2.1 mSv y(-1). The background dose in the Marshall Islands is estimated to be 2.4 mSv y(-1). The combined dose from both background and bomb related radionuclides ranges from slightly over 2.4 mSv y(-1) to 4.5 mSv y(-1). The 50-y integral dose ranges from 0.5 to 65 mSv.
Dose comparison between conventional and quasi-monochromatic systems for diagnostic radiology
NASA Astrophysics Data System (ADS)
Baldelli, P.; Taibi, A.; Tuffanelli, A.; Gambaccini, M.
2004-09-01
Several techniques have been introduced in the last year to reduce the dose to the patient by minimizing the risk of tumour induced by radiation. In this work the radiological potential of dose reduction in quasi-monochromatic spectra produced via mosaic crystal Bragg diffraction has been evaluated, and a comparison with conventional spectra has been performed for four standard examinations: head, chest, abdomen and lumbar sacral spine. We have simulated quasi-monochromatic x-rays with the Shadow code, and conventional spectra with the Spectrum Processor. By means of the PCXMC software, we have simulated four examinations according to parameters established by the European Guidelines, and calculated absorbed dose for principal organs and the effective dose. Simulations of quasi-monochromatic laminar beams have been performed without anti-scatter grid, because of their inherent scatter geometry, and compared with simulations with conventional beams with anti-scatter grids. Results have shown that the dose reduction due to the introduction of quasi-monochromatic x-rays depends on different parameters related to the quality of the beam, the organ composition and the anti-scatter grid. With parameters chosen in this study a significant dose reduction can be achieved for two out of four kinds of examination.
NASA Astrophysics Data System (ADS)
Hassan, G. M.; Rabie, N.; Mustafa, K. A.; Abdel-Khalik, S. S.
2012-09-01
Radiation exposure and image quality in X-ray diagnostic radiology provide a clear understanding of the relationship between the radiation dose delivered to a patient and image quality in optimizing medical diagnostic radiology. Because a certain amount of radiation is unavoidably delivered to patients, this should be as low as reasonably achievable. Several X-ray diagnostic machines were used at different medical diagnostic centers in Egypt for studying the beam quality and the dose delivered to the patient. This article studies the factors affecting the beam quality, such as the kilo-volt peak (kVp), exposure time (mSc), tube current (mAs) and the absorbed dose in (μGy) for different examinations. The maximum absorbed dose measured per mAs was 594±239 and 12.5±3.7 μGy for the abdomen and the chest, respectively, while the absorbed dose at the elbow was 18±6 μGy, which was the minimum dose recorded. The compound and expanded uncertainties accompanying these measurements were 4±0.35% and 8±0.7%, respectively. The measurements were done through quality control tests as acceptance procedures.
Population dose near the Semipalatinsk test site.
Hille, R; Hill, P; Bouisset, P; Calmet, D; Kluson, J; Seisebaev, A; Smagulov, S
1998-10-01
To determine the consequences of atmospheric atomic bomb tests for the population in the surroundings of the former nuclear weapons test site near Semipalatinsk in Kazakhstan, a pilot study was performed by an international cooperation between Kazakh, French, Czech and German institutions at two villages, Mostik and Maisk. Together with Kazakh scientists, eight experts from Europe carried out a field mission in September 1995 to assess, within the framework of a NATO supported project, the radiological situation as far as external doses, environmental contamination and body burden of man were concerned. A summary of the results obtained is presented. The actual radiological situation near the test site is characterized by fallout contaminations. Cs was found in upper soil layers in concentrations similar to those of the global fallout. Also Sr, Am and Co were observed. The resulting present dose to the population is low. Mean external doses from soil contamination for Maisk and Mostik (0.60-0.63 mSv/year) presently correspond to mean external doses in normal environments. Mean values of the annual internal doses observed in these two villages are below 2 microSv/year for 90Sr. For other radionuclides the internal doses are also negligible.
Teaching Radiology Physics Interactively with Scientific Notebook Software.
Richardson, Michael L; Amini, Behrang
2018-06-01
The goal of this study is to demonstrate how the teaching of radiology physics can be enhanced with the use of interactive scientific notebook software. We used the scientific notebook software known as Project Jupyter, which is free, open-source, and available for the Macintosh, Windows, and Linux operating systems. We have created a scientific notebook that demonstrates multiple interactive teaching modules we have written for our residents using the Jupyter notebook system. Scientific notebook software allows educators to create teaching modules in a form that combines text, graphics, images, data, interactive calculations, and image analysis within a single document. These notebooks can be used to build interactive teaching modules, which can help explain complex topics in imaging physics to residents. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Hands-on Physics Education of Residents in Diagnostic Radiology.
Zhang, Jie; Hardy, Peter A; DiSantis, David J; Oates, M Elizabeth
2017-06-01
The American Board of Radiology Core Examination integrates assessment of physics knowledge into its overall testing of clinical radiology, with an emphasis on understanding image quality and artifacts, radiation dose, and patient safety for each modality or subspecialty organ system. Accordingly, achieving a holistic approach to physics education of radiology residents is a huge challenge. The traditional teaching of radiological physics-simply through didactic lectures-was not designed for such a holistic approach. Admittedly, time constraints and clinical demands can make incorporation of physics teaching into clinical practice problematic. We created and implemented a week-long, intensive physics rotation for fledgling radiology residents and evaluated its effectiveness. The dedicated physics rotation is held for 1 week during the first month of radiology residency. It comprises three components: introductory lectures, hands-on practical clinical physics operations, and observation of clinical image production. A brief introduction of the physics pertinent to each modality is given at the beginning of each session. Hands-on experimental demonstrations are emphasized, receiving the greatest allotment of time. The residents perform experiments such as measuring radiation dose, studying the relationship between patient dose and clinical practice (eg, fluoroscopy technique), investigating the influence of acquisition parameters (kV, mAs) on radiographs, and evaluating image quality using computed tomography, magnetic resonance imaging, ultrasound, and gamma camera/single-photon emission computed tomography/positron emission tomography phantoms. Quantitative assessment of the effectiveness of the rotation is based on an examination that tests the residents' grasp of basic medical physics concepts along with written course evaluations provided by each resident. The pre- and post-rotation tests show that after the physics rotation, the average correct score of 25 questions improved from 13.6 ± 2.4 to 19 ± 1.2. The survey shows that the physics rotation during the first week of residency is favored by all residents and that 1 week's duration is appropriate. All residents are of the opinion that the intensive workshop would benefit them in upcoming clinical rotations. Residents acknowledge becoming more comfortable regarding the use of radiation and providing counsel regarding radiation during pregnancy. An immersive, short-duration, clinically oriented physics rotation is well received by new or less experienced radiology trainees, correlates basic physics concepts with their relevance to clinical imaging, and more closely parallels expectations of the American Board of Radiology Core Examination. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Shiradkar, Rakesh; Podder, Tarun K; Algohary, Ahmad; Viswanath, Satish; Ellis, Rodney J; Madabhushi, Anant
2016-11-10
Radiomics or computer - extracted texture features have been shown to achieve superior performance than multiparametric MRI (mpMRI) signal intensities alone in targeting prostate cancer (PCa) lesions. Radiomics along with deformable co-registration tools can be used to develop a framework to generate targeted focal radiotherapy treatment plans. The Rad-TRaP framework comprises three distinct modules. Firstly, a module for radiomics based detection of PCa lesions on mpMRI via a feature enabled machine learning classifier. The second module comprises a multi-modal deformable co-registration scheme to map tissue, organ, and delineated target volumes from MRI onto CT. Finally, the third module involves generation of a radiomics based dose plan on MRI for brachytherapy and on CT for EBRT using the target delineations transferred from the MRI to the CT. Rad-TRaP framework was evaluated using a retrospective cohort of 23 patient studies from two different institutions. 11 patients from the first institution were used to train a radiomics classifier, which was used to detect tumor regions in 12 patients from the second institution. The ground truth cancer delineations for training the machine learning classifier were made by an experienced radiation oncologist using mpMRI, knowledge of biopsy location and radiology reports. The detected tumor regions were used to generate treatment plans for brachytherapy using mpMRI, and tumor regions mapped from MRI to CT to generate corresponding treatment plans for EBRT. For each of EBRT and brachytherapy, 3 dose plans were generated - whole gland homogeneous ([Formula: see text]) which is the current clinical standard, radiomics based focal ([Formula: see text]), and whole gland with a radiomics based focal boost ([Formula: see text]). Comparison of [Formula: see text] against conventional [Formula: see text] revealed that targeted focal brachytherapy would result in a marked reduction in dosage to the OARs while ensuring that the prescribed dose is delivered to the lesions. [Formula: see text] resulted in only a marginal increase in dosage to the OARs compared to [Formula: see text]. A similar trend was observed in case of EBRT with [Formula: see text] and [Formula: see text] compared to [Formula: see text]. A radiotherapy planning framework to generate targeted focal treatment plans has been presented. The focal treatment plans generated using the framework showed reduction in dosage to the organs at risk and a boosted dose delivered to the cancerous lesions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kohlbrenner, R; Kolli, KP; Taylor, A
2014-06-01
Purpose: To quantify the patient radiation dose reduction achieved during transarterial chemoembolization (TACE) procedures performed in a body interventional radiology suite equipped with the Philips Allura Clarity imaging acquisition and processing platform, compared to TACE procedures performed in the same suite equipped with the Philips Allura Xper platform. Methods: Total fluoroscopy time, cumulative dose area product, and cumulative air kerma were recorded for the first 25 TACE procedures performed to treat hepatocellular carcinoma (HCC) in a Philips body interventional radiology suite equipped with Philips Allura Clarity. The same data were collected for the prior 85 TACE procedures performed to treatmore » HCC in the same suite equipped with Philips Allura Xper. Mean values from these cohorts were compared using two-tailed t tests. Results: Following installation of the Philips Allura Clarity platform, a 42.8% reduction in mean cumulative dose area product (3033.2 versus 1733.6 mGycm∧2, p < 0.0001) and a 31.2% reduction in mean cumulative air kerma (1445.4 versus 994.2 mGy, p < 0.001) was achieved compared to similar procedures performed in the same suite equipped with the Philips Allura Xper platform. Mean total fluoroscopy time was not significantly different between the two cohorts (1679.3 versus 1791.3 seconds, p = 0.41). Conclusion: This study demonstrates a significant patient radiation dose reduction during TACE procedures performed to treat HCC after a body interventional radiology suite was converted to the Philips Allura Clarity platform from the Philips Allura Xper platform. Future work will focus on evaluation of patient dose reduction in a larger cohort of patients across a broader range of procedures and in specific populations, including obese patients and pediatric patients, and comparison of image quality between the two platforms. Funding for this study was provided by Philips Healthcare, with 5% salary support provided to authors K. Pallav Kolli and Robert G. Gould for time devoted to the study. Data acquisition and analysis was performed by the authors independent of the funding source.« less
Webster, Gareth J; Hardy, Mark J; Rowbottom, Carl G; Mackay, Ranald I
2008-04-16
The head and neck is a challenging anatomic site for intensity-modulated radiation therapy (IMRT), requiring thorough testing of planning and treatment delivery systems. Ideally, the phantoms used should be anatomically realistic, have radiologic properties identical to those of the tissues concerned, and allow for the use of a variety of devices to verify dose and dose distribution in any target or normaltissue structure. A phantom that approaches the foregoing characteristics has been designed and built; its specific purpose is verification for IMRT treatments in the head-andneck region. This semi-anatomic phantom, HANK, is constructed of Perspex (Imperial Chemical Industries, London, U.K.) and provides for the insertion of heterogeneities simulating air cavities in a range of fixed positions. Chamber inserts are manufactured to incorporate either a standard thimble ionization chamber (0.125 cm3: PTW, Freiburg, Germany) or a smaller PinPoint chamber (0.015 cm3: PTW), and measurements can be made with either chamber in a range of positions throughout the phantom. Coronal films can also be acquired within the phantom, and additional solid blocks of Perspex allow for transverse films to be acquired within the head region. Initial studies using simple conventional head-and-neck plans established the reproducibility of the phantom and the measurement devices to within the setup uncertainty of +/- 0.5 mm. Subsequent verification of 9 clinical head-and-neck IMRT plans demonstrated the efficacy of the phantom in making a range of patient-specific dose measurements in regions of dosimetric and clinical interest. Agreement between measured values and those predicted by the Pinnacle3 treatment planning system (Philips Medical Systems, Andover, MA) was found to be generally good, with a mean error on the calculated dose to each point of +0.2% (range: -4.3% to +2.2%; n = 9) for the primary planning target volume (PTV), -0.1% (range: -1.5% to +2.0%; n = 8) for the nodal PTV, and +0.0% (range: -1.8% to +4.3%, n = 9) for the spinal cord. The suitability of the phantom for measuring combined dose distributions using radiographic film was also evaluated. The phantom has proved to be a valuable tool in the development and implementation of clinical head-and-neck IMRT, allowing for accurate verification of absolute dose and dose distributions in regions of clinical and dosimetric interest.
Radiological survey of the covered and uncovered drilling mud depository.
Jónás, Jácint; Somlai, János; Csordás, Anita; Tóth-Bodrogi, Edit; Kovács, Tibor
2018-08-01
In petroleum engineering, the produced drilling mud sometimes contains elevated amounts of natural radioactivity. In this study, a remediated Hungarian drilling mud depository was investigated from a radiological perspective. The depository was monitored before and after a clay layer was applied as covering. In this study, the ambient dose equivalent rate H*(10) of the depository has been measured by a Scintillator Probe (6150AD-b Dose Rate Meter). Outdoor radon concentration, radon concentration in soil gas, and in situ field radon exhalation measurements were carried out using a pulse-type ionization chamber (AlphaGUARD radon monitor). Soil gas permeability (k) measurements were carried out using the permeameter (RADON-JOK) in situ device. Geogenic radon potentials were calculated. The radionuclide content of the drilling mud and cover layer sample has been determined with an HPGe gamma-spectrometer. The gamma dose rate was estimated from the measured radionuclide concentrations and the results were compared with the measured ambient dose equivalent rate. Based on the measured results before and after covering, the ambient dose equivalent rates were 76 (67-85) nSv/h before and 86 (83-89) nSv/h after covering, radon exhalation was 9 (6-12) mBq/m 2 s before and 14 (5-28) mBq/m 2 s after covering, the outdoor radon concentrations were 11 (9-16) before and 13 (10-22) Bq/m 3 after covering and the soil gas radon concentrations were 6 (3-8) before and 24 (14-40) kBq/m 3 after covering. Soil gas permeability measurements were 1E-11 (7E-12-1E-11) and 1E-12 (5E-13-1E-12) m 2 and the calculated geogenic radon potential values were 6 (3-8) and 12 (6-21) before and after the covering. The main radionuclide concentrations of the drilling mud were C U-238 12 (10-15) Bq/kg, C Ra-226 31 (18-40) Bq/kg, C Th-232 35 (33-39) Bq/kg and C K-40 502 (356-673) Bq/kg. The same radionuclide concentrations in the clay were C U-238 31 (29-34) Bq/kg, C Ra-226 45 (40-51) Bq/kg, C Th-232 58 (55-60) Bq/kg and C K-40 651 (620-671) Bq/kg. According to our results, the drilling mud depository exhibits no radiological risk from any radiological aspects (radon, radon exhalation, gamma dose, etc.); therefore, long term monitoring activity is not necessary from the radiological point of view. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sasaki, S.; Yamada, T.
2013-12-01
The great earthquake attacked the north-east area in Japan in March 11, 2011. The system of electrical facilities to control Fukushima Daiichi nuclear power station was completely destroyed by the following tsunamis. From the damaged reactor containment vessels, an amount of radioactive substances had leaked and been diffused in the vicinity of this station. Radiological internal exposure becomes a serious social issue both in Japan and all over the world. The present study provides an easily understandable, kinematic-based model to estimate the effective dose of radioactive substances in a human body by simplified the complicated mechanism of metabolism. International Commission on Radiological Protection (ICRP) has developed an exact model, which is well-known as a standard method to calculate the effective dose for radiological protection. However, owing to that the above method accord too much with the actual mechanism of metabolism in human bodies, it becomes rather difficult for non-professional people of radiology to gasp the whole images of the movement and the influences of radioactive substances in a human body. Therefore, in the present paper we propose a newly-derived and easily-understandable model to estimate the effective dose. The present method is very similar with the traditional and conventional hydrological tank model. Ingestion flux of radioactive substances corresponds to rain intensity and the storage of radioactive substances to the water storage in a basin in runoff analysis. The key of this method is to estimate the energy radiated from the radioactive nuclear disintegration of an atom by using classical theory of E. Fermi of beta decay and special relativity for various kinds of radioactive atoms. The parameters used in this study are only physical half-time and biological half-time, and there are no intentional and operational parameters of coefficients to adjust our theoretical runoff to observation of ICRP. Figure.1 compares time series of effective cesium-137 dose according to age calculated by ICRP software with calculated by the present method. Plots are calculated values by ICRP, the solid line is analytic solution given from the present method. It should be noted that the present study does not consider complicated mechanism, but it could give equally accurate results comparing to existing research. Time series of effective Cs-137 dose according to age when food contains 1 Bq/year is ingested for 1 year. (Plots are calculated values by ICRP. The solid line is analytic solution given from the present method)
Changes in radiological protection and quality control in Spanish dental installations: 1996-2003.
Alcaraz-Baños, Miguel; Parra-Pérez, María del Carmen; Armero-Barranco, David; Velasco-Hidalgo, Francisco; Velasco-Hidalgo, Esteban
2009-10-01
The European Union has established specific directives concerning radiological protection which are obligatory for member States. In addition, all Spanish dental clinics with radiological equipment are required to have an annual quality control check. To analyze the effect of new European legislation on dental radiological practice in Spain and to determine whether it has resulted in lower doses being administered to patients. A total of 10,171 official radiological quality control reports on Spanish dental clinics, covering 16 autonomous regions, were studied following the passing of Royal Decree 2071/1995 on quality criteria in radiodiagnostic installations. The reports, compiled by U.T.P.R Asigma S.A., a company authorised by the Nuclear Safety Council, cover the years 1996 to 2003, which has enabled us to monitor the evolution of radiological procedures in dental clinics over a seven year period. According to the reports for 2003, 77.3 % of clinics complied with EU requirements, using equipment of 70 kVp, 8 mA, 1.5 mm Al filters, with a collimator length of 20 cm. However, non-compliance was detected in approximately a third (30.8%) of the equipment inspected: alterations in the kilovoltage used, exposure time, performance of the tubing, dosage, linearity/intensity of current and acoustic-luminous signal 6.86%. The mean skin dose reached 3.11 mGy for patients who received an x-ray of an upper molar, representing a decrease of 18% over the seven years studied. there has obviously been a general improvement in the parameters studied, but only 77.3% of the installations complied fully with official EU regulations concerning dental radiological protection.
Estimates of radiological risk from depleted uranium weapons in war scenarios.
Durante, Marco; Pugliese, Mariagabriella
2002-01-01
Several weapons used during the recent conflict in Yugoslavia contain depleted uranium, including missiles and armor-piercing incendiary rounds. Health concern is related to the use of these weapons, because of the heavy-metal toxicity and radioactivity of uranium. Although chemical toxicity is considered the more important source of health risk related to uranium, radiation exposure has been allegedly related to cancers among veterans of the Balkan conflict, and uranium munitions are a possible source of contamination in the environment. Actual measurements of radioactive contamination are needed to assess the risk. In this paper, a computer simulation is proposed to estimate radiological risk related to different exposure scenarios. Dose caused by inhalation of radioactive aerosols and ground contamination induced by Tomahawk missile impact are simulated using a Gaussian plume model (HOTSPOT code). Environmental contamination and committed dose to the population resident in contaminated areas are predicted by a food-web model (RESRAD code). Small values of committed effective dose equivalent appear to be associated with missile impacts (50-y CEDE < 5 mSv), or population exposure by water-independent pathways (50-y CEDE < 80 mSv). The greatest hazard is related to the water contamination in conditions of effective leaching of uranium in the groundwater (50-y CEDE < 400 mSv). Even in this worst case scenario, the chemical toxicity largely predominates over radiological risk. These computer simulations suggest that little radiological risk is associated to the use of depleted uranium weapons.
Radiation Dose Optimization For Critical Organs
NASA Astrophysics Data System (ADS)
Khodadadegan, Yasaman
Ionizing radiation used in the patient diagnosis or therapy has negative effects on the patient body in short term and long term depending on the amount of exposure. More than 700,000 examinations are everyday performed on Interventional Radiology modalities, however; there is no patient-centric information available to the patient or the Quality Assurance for the amount of organ dose received. In this study, we are exploring the methodologies to systematically reduce the absorbed radiation dose in the Fluoroscopically Guided Interventional Radiology procedures. In the first part of this study, we developed a mathematical model which determines a set of geometry settings for the equipment and a level for the energy during a patient exam. The goal is to minimize the amount of absorbed dose in the critical organs while maintaining image quality required for the diagnosis. The model is a large-scale mixed integer program. We performed polyhedral analysis and derived several sets of strong inequalities to improve the computational speed and quality of the solution. Results present the amount of absorbed dose in the critical organ can be reduced up to 99% for a specific set of angles. In the second part, we apply an approximate gradient method to simultaneously optimize angle and table location while minimizing dose in the critical organs with respect to the image quality. In each iteration, we solve a sub-problem as a MIP to determine the radiation field size and corresponding X-ray tube energy. In the computational experiments, results show further reduction (up to 80%) of the absorbed dose in compare with previous method. Last, there are uncertainties in the medical procedures resulting imprecision of the absorbed dose. We propose a robust formulation to hedge from the worst case absorbed dose while ensuring feasibility. In this part, we investigate a robust approach for the organ motions within a radiology procedure. We minimize the absorbed dose for the critical organs across all input data scenarios which are corresponding to the positioning and size of the organs. The computational results indicate up to 26% increase in the absorbed dose calculated for the robust approach which ensures the feasibility across scenarios.
Assessing potential radiological harm to fukushima recovery workers.
Scott, Bobby R
2011-01-01
A radiological emergency exists at the Fukushima Daiichi (Fukushima I) nuclear power plant in Japan as a result of the March 11, 2011 magnitude 9.0 earthquake and the massive tsunami that arrived later. News media misinformation related to the emergency triggered enormous social fear worldwide of the radioactivity that is being released from damaged fuel rods. The heroic recovery workers are a major concern because they are being exposed to mostly gamma radiation during their work shifts and life-threatening damage to the radiosensitive bone marrow could occur over time. This paper presents a way in which the bone marrow equivalent dose (in millisieverts), as estimated per work shift, could be used along with the hazard function model previously developed for radiological risk assessment to repeatedly check for potential life-threatening harm (hematopoietic system damage) to workers. Three categories of radiation hazard indication are proposed: 1, life-threatening damage unlikely; 2, life-threatening damage possible; 3, life-threatening damage likely. Categories 2 and 3 would be avoided if the whole body effective dose did not exceed the annual effective dose limit of 250 mSv. For down-wind populations, hormetic effects (activated natural protective processes) are much more likely than are deleterious effects.
Croymans, Tom; Schroeyers, Wouter; Krivenko, Pavel; Kovalchuk, Oleksandr; Pasko, Anton; Hult, Mikael; Marissens, Gerd; Lutter, Guillaume; Schreurs, Sonja
2017-03-01
Bauxite residue, also known as red mud, can be used as an aggregate in concrete products. The study involves the radiological characterization of different types of concretes containing bauxite residue from Ukraine. The activity concentrations of radionuclides from the 238 U, 232 Th decay series and 40 K were determined for concrete mixture samples incorporating 30, 40, 50, 60, 75, 85 and 90% (by mass) of bauxite residue using gamma-ray spectrometry with a HPGe detector. The studied bauxite residue can, from a radiological point of view using activity concentration indexes developed by Markkanen, be used in concrete for building materials and in road construction, even in percentages reaching 90% (by mass). However, when also occupational exposure is considered it is recommended to incorporate less than 75% (by mass) of Ukrainian bauxite residue during the construction of buildings in order to keep the dose to workers below the dose criterion used by Radiation Protection (RP) 122 (0.3 mSv/a). Considering RP122 for evaluation of the total effective dose to workers no restrictions are required for the use of the Ukrainian bauxite residue in road construction. Copyright © 2016 Elsevier Ltd. All rights reserved.
Harrison, John D.; Leggett, Richard Wayne
2016-01-01
This letter to the editor of Journal of Radiological Protection is in response to a letter to the editor from G. M. Smith and M. C. Thorne of Great Britain concerning the appropriate selection of dose coefficients for ingested carbon-14 and chlorine-36, two of the most important long-lived components of radioactive wastes. Smith and Thorne argue that current biokinetic models of the International Commission on Radiological Protection (ICRP) for carbon and chlorine are overly cautious models from the standpoint of radiation dose estimates for C-14 and Cl-36, and that more realistic models are needed for evaluation of the hazards ofmore » these radionuclides in nuclear wastes. We (Harrison and Leggett) point out that new biokinetic models for these and other elements (developed at ORNL) will soon appear in ICRP Publications. These new models generally are considerably more realistic than current ICRP models. Here, examples are given for C-14 inhaled as carbon dioxide or ingested in water as bicarbonate, carbonate, or carbon dioxide.« less
NASA Astrophysics Data System (ADS)
Dan, Posa Ioan; Florin, Georgescu Remus; Virgil, Ciobanu; Antonescu, Elisabeta
2011-09-01
The place of the study is a pediatrics clinic which realizes a great variety of emergency, ambulatory ad hospital examinations. The radiology compartment respects work procedures and a system to ensure the quality of X ray examinations. The results show a constant for the programmator of the digital detector machine for the tension applied to the tube. For the screen-film detector machine the applied tension increases proportionally with the physical development of the child considering the trunk thickness.
Which is the best way of performing a Micturating Cystourethrogram in children?
Al-Imam, Ola Ali; Al-Nsour, Nareeman Moh'd; Al-Khulaifat, Samih
2008-01-01
The Micturating Cystourethrogram (MCU) is a tough and stressful examination for patients and their parents as well as the radiologists and pediatric radiology nurses. Even though, it is one of the most commonly used fluoroscopic procedures in pediatric radiology practice, there is no definite agreement as to the best way to perform it, considering that this examination results in the children receiving a high dose of radiation to the gonadal region. This review was undertaken to determine the best way to perform the MCU in modern pediatric radiology practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Pei-Jan P., E-mail: Pei-Jan.Lin@vcuhealth.org; Schueler, Beth A.; Balter, Stephen
2015-12-15
Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose-area-product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP-meter” has been revised to air kerma-area product (KAP) meter. The charge of TGmore » 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.« less
NOTE: Dose area product evaluations with Gafchromic® XR-R films and a flat-bed scanner
NASA Astrophysics Data System (ADS)
Rampado, O.; Garelli, E.; Deagostini, S.; Ropolo, R.
2006-12-01
Gafchromic® XR-R films are a useful tool to evaluate entrance skin dose in interventional radiology. Another dosimetric quantity of interest in diagnostic and interventional radiology is the dose area product (DAP). In this study, a method to evaluate DAP using Gafchromic® XR-R films and a flat-bed scanner was developed and tested. Film samples were exposed to an x-ray beam of 80 kVp over a dose range of 0 10 Gy. DAP measurements with films were obtained from the digitalization of a film sample positioned over the x-ray beam window during the exposure. DAP values obtained with this method were compared for 23 cardiological interventional procedures with DAP values displayed by the equipment. The overall one-sigma dose measurement uncertainty depended on the absorbed dose, with values below 6% for doses above 1 Gy. A maximum discrepancy of 16% was found, which is of the order of the differences in the DAP measurements that may occur with different calibration procedures. Based on the results presented, after an accurate calibration procedure and a thorough inspection of the relationship between the actual dose and the direct measured quantity (net optical density or net pixel value variation), Gafchromic® XR-R films can be used to assess the DAP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damet, J., E-mail: jerome.damet@chuv.ch; Fournier, P.; Monnin, P.
Purpose: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. Methods: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectorsmore » and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). Results: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. Conclusions: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.« less
Method and apparatus for laser-controlled proton beam radiology
Johnstone, Carol J.
1998-01-01
A proton beam radiology system provides cancer treatment and proton radiography. The system includes an accelerator for producing an H.sup.- beam and a laser source for generating a laser beam. A photodetachment module is located proximate the periphery of the accelerator. The photodetachment module combines the H.sup.- beam and laser beam to produce a neutral beam therefrom within a subsection of the H.sup.- beam. The photodetachment module emits the neutral beam along a trajectory defined by the laser beam. The photodetachment module includes a stripping foil which forms a proton beam from the neutral beam. The proton beam is delivered to a conveyance segment which transports the proton beam to a patient treatment station. The photodetachment module further includes a laser scanner which moves the laser beam along a path transverse to the cross-section of the H.sup.- beam in order to form the neutral beam in subsections of the H.sup.- beam. As the scanning laser moves across the H.sup.- beam, it similarly varies the trajectory of the proton beam emitted from the photodetachment module and in turn varies the target location of the proton beam upon the patient. Intensity modulation of the proton beam can also be achieved by controlling the output of the laser.
Method and apparatus for laser-controlled proton beam radiology
Johnstone, C.J.
1998-06-02
A proton beam radiology system provides cancer treatment and proton radiography. The system includes an accelerator for producing an H{sup {minus}} beam and a laser source for generating a laser beam. A photodetachment module is located proximate the periphery of the accelerator. The photodetachment module combines the H{sup {minus}} beam and laser beam to produce a neutral beam therefrom within a subsection of the H{sup {minus}} beam. The photodetachment module emits the neutral beam along a trajectory defined by the laser beam. The photodetachment module includes a stripping foil which forms a proton beam from the neutral beam. The proton beam is delivered to a conveyance segment which transports the proton beam to a patient treatment station. The photodetachment module further includes a laser scanner which moves the laser beam along a path transverse to the cross-section of the H{sup {minus}} beam in order to form the neutral beam in subsections of the H{sup {minus}} beam. As the scanning laser moves across the H{sup {minus}} beam, it similarly varies the trajectory of the proton beam emitted from the photodetachment module and in turn varies the target location of the proton beam upon the patient. Intensity modulation of the proton beam can also be achieved by controlling the output of the laser. 9 figs.
De Cock, Jens; Zanca, Federica; Canning, John; Pauwels, Ruben; Hermans, Robert
2015-07-01
To evaluate image quality and radiation dose of a state of the art cone beam computed tomography (CBCT) system and a multislice computed tomography (MSCT) system in patients with sinonasal poliposis. In this retrospective study two radiologists evaluated 57 patients with sinonasal poliposis who underwent a CBCT or MSCT sinus examination, along with a control group of 90 patients with normal radiological findings. Tissue doses were measured using a phantom model with thermoluminescent dosimeters (TLD). Overall image quality in CBCT was scored significantly higher than in MSCT in patients with normal radiologic findings (p-value: 0.00001). In patients with sinonasal poliposis, MSCT scored significantly higher than CBCT (p-value: 0.00001). The average effective dose for MSCT was 42% higher compared to CBCT (108 μSv vs 63 μSv). CBCT and MSCT are both suited for the evaluation of sinonasal poliposis. In patients with sinonasal poliposis, clinically important structures of the paranasal sinuses can be better delineated with MSCT, whereas in patients without sinonasal poliposis, CBCT turns out to define the important structures of the sinonasal region better. However, given the lower radiation dose, CBCT can be considered for the evaluation of the sinonasal structures in patients with sinonasal poliposis. • CBCT and MSCT are both suited for evaluation of sinonasal poliposis. • Effective dose for MSCT was 42% higher compared to CBCT. • In patients with sinonasal poliposis, clinically important anatomical structures are better delineated with MSCT. • In patients with normal radiological findings, clinically important anatomical structures are better delineated with CBCT.
SUDOQU, a new dose-assessment methodology for radiological surface contamination.
van Dillen, Teun; van Dijk, Arjan
2018-06-12
A new methodology has been developed for the assessment of the annual effective dose resulting from removable and fixed radiological surface contamination. It is entitled SUDOQU (SUrface DOse QUantification) and it can for instance be used to derive criteria for surface contamination related to the import of non-food consumer goods, containers and conveyances, e.g., limiting values and operational screening levels. SUDOQU imposes mass (activity)-balance equations based on radioactive decay, removal and deposition processes in indoor and outdoor environments. This leads to time-dependent contamination levels that may be of particular importance in exposure scenarios dealing with one or a few contaminated items only (usually public exposure scenarios, therefore referred to as the 'consumer' model). Exposure scenarios with a continuous flow of freshly contaminated goods also fall within the scope of the methodology (typically occupational exposure scenarios, thus referred to as the 'worker model'). In this paper we describe SUDOQU, its applications, and its current limitations. First, we delineate the contamination issue, present the assumptions and explain the concepts. We describe the relevant removal, transfer, and deposition processes, and derive equations for the time evolution of the radiological surface-, air- and skin-contamination levels. These are then input for the subsequent evaluation of the annual effective dose with possible contributions from external gamma radiation, inhalation, secondary ingestion (indirect, from hand to mouth), skin contamination, direct ingestion and skin-contact exposure. The limiting effective surface dose is introduced for issues involving the conservatism of dose calculations. SUDOQU can be used by radiation-protection scientists/experts and policy makers in the field of e.g. emergency preparedness, trade and transport, exemption and clearance, waste management, and nuclear facilities. Several practical examples are worked out demonstrating the potential applications of the methodology. . Creative Commons Attribution license.
NASA Astrophysics Data System (ADS)
Sulieman, A.; Elhadi, T.; Babikir, E.; Alkhorayef, M.; Alnaaimi, M.; Alduaij, M.; Bradley, D. A.
2017-11-01
In many countries diagnostic medical exposures typically account for a very large fraction of the collective effective dose that can be assigned to anthropological sources and activities. This in part flags up the question of whether sufficient steps are being taken in regard to potential dose saving from such medical services. As a first step, one needs to survey doses to compare against those of best practice. The present study has sought evaluation of the radiation protection status and patient doses for certain key radiological procedures in four film-based radiology departments within Sudan. The radiation exposure survey, carried out using a survey meter and quality control test tools, involved a total of 299 patients their examinations being carried out at one or other of these four departments. The entrance surface air kerma (ESAK) was determined from exposure settings using DosCal software and an Unfors -Xi-meter. The mean ESAK for x-ray examination of the chest was 0.30±0.1 mGy, for the skull it was 0.96±0.7 mGy, for the abdomen 0.85±0.01 mGy, for spinal procedures 1.30±0.6 mGy and for procedures involving the limbs it was 0.43±0.3 mGy. Ambient dose-rates in the reception area, at the closed door of the x-ray room, recorded instantaneous values of up to 100 μSv/h. In regard to protection, the associated levels were found to be acceptable in three of the four departments, corrective action being required for one department, regular quality control also being recommended.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onal, Cem, E-mail: hcemonal@hotmail.com; Arslan, Gungor; Dolek, Yemliha
2016-01-01
The aim of this study is to evaluate the incidental testicular doses during prostate radiation therapy with intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc radiotherapy (VMAT) at different energies. Dosimetric data of 15 patients with intermediate-risk prostate cancer who were treated with radiotherapy were analyzed. The prescribed dose was 78 Gy in 39 fractions. Dosimetric analysis compared testicular doses generated by 7-field intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy with a single arc at 6, 10, and 15 MV energy levels. Testicular doses calculated from the treatment planning system and doses measured from the detectors were analyzed. Mean testicular doses from themore » intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy per fraction calculated in the treatment planning system were 16.3 ± 10.3 cGy vs 21.5 ± 11.2 cGy (p = 0.03) at 6 MV, 13.4 ± 10.4 cGy vs 17.8 ± 10.7 cGy (p = 0.04) at 10 MV, and 10.6 ± 8.5 cGy vs 14.5 ± 8.6 cGy (p = 0.03) at 15 MV, respectively. Mean scattered testicular doses in the phantom measurements were 99.5 ± 17.2 cGy, 118.7 ± 16.4 cGy, and 193.9 ± 14.5 cGy at 6, 10, and 15 MV, respectively, in the intensity-modulated radiotherapy plans. In the volumetric-modulated arc radiotherapy plans, corresponding testicular doses per course were 90.4 ± 16.3 cGy, 103.6 ± 16.4 cGy, and 139.3 ± 14.6 cGy at 6, 10, and 15 MV, respectively. In conclusions, this study was the first to measure the incidental testicular doses by intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy plans at different energy levels during prostate-only irradiation. Higher photon energy and volumetric-modulated arc radiotherapy plans resulted in higher incidental testicular doses compared with lower photon energy and intensity-modulated radiotherapy plans.« less
Bellesi, Luca; Wyttenbach, Rolf; Gaudino, Diego; Colleoni, Paolo; Pupillo, Francesco; Carrara, Mauro; Braghetti, Antonio; Puligheddu, Carla; Presilla, Stefano
2017-01-01
The aim of this work was to evaluate detection of low-contrast objects and image quality in computed tomography (CT) phantom images acquired at different tube loadings (i.e. mAs) and reconstructed with different algorithms, in order to find appropriate settings to reduce the dose to the patient without any image detriment. Images of supraslice low-contrast objects of a CT phantom were acquired using different mAs values. Images were reconstructed using filtered back projection (FBP), hybrid and iterative model-based methods. Image quality parameters were evaluated in terms of modulation transfer function; noise, and uniformity using two software resources. For the definition of low-contrast detectability, studies based on both human (i.e. four-alternative forced-choice test) and model observers were performed across the various images. Compared to FBP, image quality parameters were improved by using iterative reconstruction (IR) algorithms. In particular, IR model-based methods provided a 60% noise reduction and a 70% dose reduction, preserving image quality and low-contrast detectability for human radiological evaluation. According to the model observer, the diameters of the minimum detectable detail were around 2 mm (up to 100 mAs). Below 100 mAs, the model observer was unable to provide a result. IR methods improve CT protocol quality, providing a potential dose reduction while maintaining a good image detectability. Model observer can in principle be useful to assist human performance in CT low-contrast detection tasks and in dose optimisation.
Effects of soil water content on the external exposure of fauna to radioactive isotopes.
Beaugelin-Seiller, K
2016-01-01
Within a recent model intercomparison about radiological risk assessment for contaminated wetlands, the influence of soil saturation conditions on external dose rates was evidenced. This issue joined concerns of assessors regarding the choice of the soil moisture value to input in radiological assessment tools such as the ERICA Tool. Does it really influence the assessment results and how? This question was investigated under IAEA's Modelling and Data for Radiological Impacts Assessments (MODARIA) programme via 42 scenarios for which the soil water content varied from 0 (dry soil) to 100% (saturated soil), in combination with other parameters that may influence the values of the external dose conversion coefficients (DCCs) calculated for terrestrial organisms exposed in soil. A set of α, β, and γ emitters was selected in order to cover the range of possible emission energies. The values of their external DCCs varied generally within a factor 1 to 1.5 with the soil water content, excepted for β emitters that appeared more sensitive (DCCs within a factor of about 3). This may be of importance for some specific cases or for upper tiers of radiological assessments, when refinement is required. But for the general purpose of screening assessment of radiological impact on fauna and flora, current approaches regarding the soil water content are relevant. Copyright © 2015 Elsevier Ltd. All rights reserved.
Korean anatomical reference data for adults for use in radiological protection
NASA Astrophysics Data System (ADS)
Choi, Chansoo; Yeom, Yeon Soo; Nguyen, Thang Tat; Lee, Hanjin; Han, Haegin; Shin, Bangho; Zhang, Xujia; Kim, Chan Hyeong; Chung, Beom Sun
2018-01-01
For radiological protection from exposure to ionizing radiation, in which a population-averaged dose evaluation is used, establishing a system of reference anatomical and physiological data for a specific population of interest is important. Some studies were done in the past to establish Korean reference data; however, the data provided the mass values only for a limited number of organs/tissues. In addition, the standing height and total body mass are based on 20-year-old data. In the present study, a new set of Korean reference anatomical values was established for use in the radiological protection of Korean workers and members of the public. The established Korean reference data provide the masses of 58 organs/tissues, including those needed to calculate the effective dose, which were derived by collecting and analyzing various scientific reports in the literature and data. In addition, the data provide not only standing height and total body mass, but also 131 additional anthropometric parameters; these values were derived from the most recent Korean national survey project, 7 th Size Korea. The characteristics of the data were also compared with several other population data, including the Asian and the International Commission on Radiological Protection (ICRP) reference data.
Korir, Geoffrey; Karam, P Andrew
2018-06-11
In the event of a significant radiological release in a major urban area where a large number of people reside, it is inevitable that radiological screening and dose assessment must be conducted. Lives may be saved if an emergency response plan and radiological screening method are established for use in such cases. Thousands to tens of thousands of people might present themselves with some levels of external contamination and/or the potential for internal contamination. Each of these individuals will require varying degrees of radiological screening, and those with a high likelihood of internal and/or external contamination will require radiological assessment to determine the need for medical attention and decontamination. This sort of radiological assessment typically requires skilled health physicists, but there are insufficient numbers of health physicists in any city to perform this function for large populations, especially since many (e.g., those at medical facilities) are likely to be engaged at their designated institutions. The aim of this paper is therefore to develop and describe the technical basis for a novel, scoring-based methodology that can be used by non-health physicists for performing radiological assessment during such radiological events.
Management of cosmic radiation exposure for aircraft crew in Japan.
Yasuda, Hiroshi; Sato, Tatsuhiko; Yonehara, Hidenori; Kosako, Toshiso; Fujitaka, Kazunobu; Sasaki, Yasuhito
2011-07-01
The International Commission on Radiological Protection has recommended that cosmic radiation exposure of crew in commercial jet aircraft be considered as occupational exposure. In Japan, the Radiation Council of the government has established a guideline that requests domestic airlines to voluntarily keep the effective dose of cosmic radiation for aircraft crew below 5 mSv y(-1). The guideline also gives some advice and policies regarding the method of cosmic radiation dosimetry, the necessity of explanation and education about this issue, a way to view and record dose data, and the necessity of medical examination for crew. The National Institute of Radiological Sciences helps the airlines to follow the guideline, particularly for the determination of aviation route doses by numerical simulation. The calculation is performed using an original, easy-to-use program package called 'JISCARD EX' coupled with a PHITS-based analytical model and a GEANT4-based particle tracing code. The new radiation weighting factors recommended in 2007 are employed for effective dose determination. The annual individual doses of aircraft crew were estimated using this program.
NASA Astrophysics Data System (ADS)
Santos, W. S.; Carvalho, A. B., Jr.; Hunt, J. G.; Maia, A. F.
2014-02-01
The objective of this study was to estimate doses in the physician and the nurse assistant at different positions during interventional radiology procedures. In this study, effective doses obtained for the physician and at points occupied by other workers were normalised by air kerma-area product (KAP). The simulations were performed for two X-ray spectra (70 kVp and 87 kVp) using the radiation transport code MCNPX (version 2.7.0), and a pair of anthropomorphic voxel phantoms (MASH/FASH) used to represent both the patient and the medical professional at positions from 7 cm to 47 cm from the patient. The X-ray tube was represented by a point source positioned in the anterior posterior (AP) and posterior anterior (PA) projections. The CC can be useful to calculate effective doses, which in turn are related to stochastic effects. With the knowledge of the values of CCs and KAP measured in an X-ray equipment, at a similar exposure, medical professionals will be able to know their own effective dose.
Radiological maps for Trabzon, Turkey.
Kurnaz, A; Kucukomeroglu, B; Damla, N; Cevik, U
2011-04-01
The activity concentrations and absorbed gamma dose rates due to primordial radionuclides and (137)Cs have been ascertained in 222 soil samples in 18 counties of the Trabzon province of Turkey using a HPGe detector. The mean activity concentrations of (238)U, (232)Th, (40)K and (137)Cs in soil samples were 41, 35, 437 and 21 Bq kg(-1), respectively. Based on the measured concentrations of these radionuclides, the mean absorbed gamma dose in air was calculated as 59 nGy h(-1) and hence, the mean annual effective dose due to terrestrial gamma radiation was calculated as 72 μSv y(-1). In addition, outdoor in situ gamma dose rate (D) measurements were performed in the same 222 locations using a portable NaI detector and the annual effective dose was calculated to be 66 μSv y(-1) from these results. The results presented in this study are compared with other parts of Turkey. Radiological maps of the Trabzon province were composed using the results obtained from the study. Copyright © 2011 Elsevier Ltd. All rights reserved.
Simulation of computed tomography dose based on voxel phantom
NASA Astrophysics Data System (ADS)
Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun
2017-01-01
Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.
Toxicology profiles of chemical and radiological contaminants at Hanford
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harper, B.L.; Strenge, D.L.; Stenner, R.D.
1995-07-01
This document summarizes toxicology information required under Section 3.3 (Toxicity Assessment) of HSRAM, and can also be used to develop the short toxicology profiles required in site assessments (described in HSRAM, Section 3.3.5). Toxicology information is used in the dose-response step of the risk assessment process. The dose-response assessment describes the quantitative relationship between the amount of exposure to a substance and the extent of toxic injury or disease. Data are derived from animal studies or, less frequently, from studies in exposed human populations. The risks of a substance cannot be ascertained with any degree of confidence unless dose-response relationsmore » are quantified. This document summarizes dose-response information available from the US Environmental Protection Agency (EPA). The contaminants selected for inclusion in this document represent most of the contaminants found at Hanford (both radiological and chemical), based on sampling and analysis performed during site investigations, and historical information on waste disposal practices at the Hanford Site.« less
Radon survey and soil gamma doses in primary schools of Batman, Turkey.
Damla, Nevzat; Aldemir, Kamuran
2014-06-01
A survey was conducted to evaluate levels of indoor radon and gamma doses in 42 primary schools located in Batman, southeastern Anatolia, Turkey. Indoor radon measurements were carried out using CR-39 solid-state nuclear track detector-based radon dosimeters. The overall mean annual (222)Rn activity in the surveyed area was found to be 49 Bq m(-3) (equivalent to an annual effective dose of 0.25 mSv). However, in one of the districts (Besiri) the maximum radon value turned out to be 307 Bq m(-3). The estimated annual effective doses are less than the recommended action level (3-10 mSv). It is found that the radon concentration decreases with increasing floor number. The concentrations of natural and artificial radioisotopes were determined using gamma-ray spectroscopy for soil samples collected in close vicinity of the studied schools. The mean gamma activity concentrations in the soil samples were 31, 25, 329 and 12 Bq kg(-1) for (226)Ra, (232)Th, (40)K and (137)Cs, respectively. The radiological parameters such as the absorbed dose rate in air and the annual effective dose equivalent were calculated. These radiological parameters were evaluated and compared with the internationally recommended values.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strom, Daniel J.
2005-01-14
In 1981, as part of a symposium entitled ''The Control of Exposure of the Public to Ionizing Radiation in the Event of Accident or Attack,'' Lushbaugh, H?bner, and Fry published a paper examining ''radiation tolerance'' of various human health endpoints as a function of dose rate. This paper may not have received the notice it warrants. The health endpoints examined by Lushbaugh et al. were the lethal dose that will kill 50% of people within 60 days of exposure without medical care (LD50/60); severe bone marrow damage in healthy men; severe bone marrow damage in leukemia patients; temporary sterility (azoospermia);more » reduced male fertility; and late effects such as cancer. Their analysis was grounded in extensive clinical experience and anchored to a few selected data points, and based on the 1968 dose-rate dependence theory of J.L. Bateman. The Lushbaugh et al. paper did not give predictive equations for the relationships, although they were implied in the text, and the relationships were presented in a non-intuitive way. This work derives the parameters needed in Bateman's equation for each health endpoint, tabulates the results, and plots them in a more conventional manner on logarithmic scales. The results give a quantitative indication of how the human organism can tolerate more radiation dose when it is delivered at lower dose rates. For example, the LD50/60 increases from about 3 grays (300 rads) when given at very high dose rates to over 10 grays (1,000 rads) when given at much lower dose rates over periods of several months. The latter figure is borne out by the case of an individual who survived for at least 19 years after receiving doses in the range of 9 to 17 grays (900-1700 rads) over 106 days. The Lushbaugh et al. work shows the importance of sheltering when confronted with long-term exposure to radiological contamination such as would be expected from a radiological dispersion event, reactor accident, or ground-level nuclear explosion.« less
Health Instruction Packages: Medical Technologies--EEG, Radiology, & Biomedical Photography.
ERIC Educational Resources Information Center
Brittenham, Dorothea; And Others
Text, illustrations, and exercises are utilized in this set of four learning modules to instruct medical technology students in a variety of job-related skills. The first module, "EEG Technology: Measurement Technique of the 'International 10-20 System'" by Dorothea Brittenham, describes a procedure used by electroencephalograph…
Radiology Aide. Instructor's Guide.
ERIC Educational Resources Information Center
Hronek, Dennis
This module was designed to assist educators in facilitating learning in health careers outside nursing. It may be used for classroom, on-the-job, or independent study. The module is oranized in 13 units. Each unit includes one or more lessons that contain the following components: scope of unit, unit objectives; student's information assignment,…
Yam, Chun-Shan; Kruskal, Jonathan; Pedrosa, Ivan; Kressel, Herbert
2006-06-01
The effectiveness of using a Digital Imaging and Communications in Medicine (DICOM)-based interactive examination system in evaluating the readiness of first year radiology residents before taking overnight call in the emergency department (ED) was reported in part I of this article. This report describes technical aspects for the design and implementation of this system. The examination system consists of two modules: Data Collection and Image Viewing. The Data Collection module was a personal computer (PC)-based DICOM storage server based on a free public domain software package, the Mallinckrodt Central Test Node. The Image Viewing module was a Java-based DICOM viewer created using another freeware package: zDicom ActiveX component. The examination takes place once a year at the end of the first 6-month rotation. Cases selected for the examination were actual clinical cases according to the American Society of Emergency Radiology core curriculum. In the 3-hour timed examination, each resident was required to read the cases and provide clinical findings and recommendations. Upper-level residents also participated in the examination to serve as a control. Answers were scored by two staff radiologists. We have been using this examination system successfully in our institution since 2003 to evaluate the readiness of the first-year residents before they take overnight call in the ED. This report describes a step-by-step procedure for implementing this system into a PC-based platform. This DICOM viewing software is available as freeware to other academic radiology institutions. The total cost for implementing this system is approximately 2000 US dollars.
Lim-Dunham, Jennifer E; Ensminger, David C; McNulty, John A; Hoyt, Amy E; Chandrasekhar, Arcot J
2016-02-01
The principles of Collins' cognitive apprenticeship model were used to design a radiology curriculum in which medical students practice radiological skills using online case-based modules. The modules are embedded within clinical third-year clerkships, and students are provided with personalized feedback from the instructors. We describe the development of the vertical online radiology curriculum and evaluate its impact on student achievement and learning process using a mixed method approach. The curriculum was developed over a 2-year period. Student participation was voluntary in the first year and mandatory in the second year. For quantitative curriculum evaluation, student metrics for voluntary versus mandatory groups were assessed using independent sample t tests and variable entry method regression analysis. For qualitative analysis, responses from a survey of students about the value of the curriculum were organized into defined themes using consensus coding. Mandatory participation significantly improved (p = .001) the mean radiology examination score (82 %) compared to the voluntary group (73%), suggesting that mandatory participation had a beneficial effect on student performance. Potential preexisting differences in underlying general academic performance were accounted for by including mean basic science grades as the first variable in the regression model. The significant increase in R(2) from .16 to .28 when number of radiology cases completed was added to the original model, and the greater value of the standardized beta for this variable, suggest that the curriculum made a significant contribution to students' radiology examination scores beyond their baseline academic performance. Five dominant themes about curricular characteristics that enhanced student learning and beneficial outcomes emerged from consensus coding. These themes were (1) self-paced design, (2) receiving feedback from faculty, (3) clinical relevance of cases, (4) gaining confidence in interpreting radiological images, and (5) transfer of conceptual knowledge to actual practice. The vertically integrated online radiology curriculum can positively impact student performance and learning process in the context of the cognitive apprenticeship model. Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
He, Wenjun; Mah, Eugene; Huda, Walter; Selby, Bayne; Yao, Hai
2011-03-01
Purpose: To investigate the dose distributions in water cylinders simulating patients undergoing Interventional Radiological examinations. Method: The irradiation geometry consisted of an x-ray source, dose-area-product chamber, and image intensifier as currently used in Interventional Radiology. Water cylinders of diameters ranging between 17 and 30 cm were used to simulate patients weighing between 20 and 90 kg. X-ray spectra data with peak x-ray tube voltages ranging from 60 to 120 kV were generated using XCOMP3R. Radiation dose distributions inside the water cylinder (Dw) were obtained using MCNP5. The depth dose distribution along the x-ray beam central axis was normalized to free-in-air air kerma (AK) that is incident on the phantom. Scattered radiation within the water cylinders but outside the directly irradiated region was normalized to the dose at the edge of the radiation field. The total absorbed energy to the directly irradiated volume (Ep) and indirectly irradiated volume (Es) were also determined and investigated as a function of x-ray tube voltage and phantom size. Results: At 80 kV, the average Dw/AK near the x-ray entrance point was 1.3. The ratio of Dw near the entrance point to Dw near the exit point increased from ~ 26 for the 17 cm water cylinder to ~ 290 for the 30 cm water cylinder. At 80 kV, the relative dose for a 17 cm water cylinder fell to 0.1% at 49 cm away from the central ray of the x-ray beam. For a 30 cm water cylinder, the relative dose fell to 0.1% at 53 cm away from the central ray of the x-ray beam. At a fixed x-ray tube voltage of 80 kV, increasing the water cylinder diameter from 17 to 30 cm increased the Es/(Ep+Es) ratio by about 50%. At a fixed water cylinder diameter of 24 cm, increasing the tube voltage from 60 kV to 120 kV increased the Es/(Ep+Es) ratio by about 12%. The absorbed energy from scattered radiation was between 20-30% of the total energy absorbed by the water cylinder, and was affected more by patient size than x-ray beam energy. Conclusion: MCNP offers a powerful tool to study the absorption and transmission of x-ray energy in phantoms that can be designed to represent patients undergoing Interventional Radiological procedures. This ability will permit a systematic investigation of the relationship between patient dose and diagnostic image quality, and thereby keep patient doses As Low As Reasonably Achievable (ALARA).
Vano, E; Sanchez, R M; Fernandez, J M
2015-07-01
The purpose of this article is to estimate lens doses using over apron active personal dosemeters in interventional catheterisation laboratories (cardiology IC, neuroradiology IN and radiology IR) and to investigate correlations between occupational lens doses and patient doses. Active electronic personal dosemeters placed over the lead apron were used on a sample of 204 IC procedures, 274 IN and 220 IR (all performed at the same university hospital). Patient dose values (kerma area product) were also recorded to evaluate correlations with occupational doses. Operators used the ceiling-suspended screen in most cases. The median and third quartile values of equivalent dose Hp(10) per procedure measured over the apron for IC, IN and IR resulted, respectively, in 21/67, 19/44 and 24/54 µSv. Patient dose values (median/third quartile) were 75/128, 83/176 and 61/159 Gy cm(2), respectively. The median ratios for dosemeters worn over the apron by operators (protected by the ceiling-suspended screen) and patient doses were 0.36; 0.21 and 0.46 µSv Gy(-1) cm(-2), respectively. With the conservative approach used (lens doses estimated from the over apron chest dosemeter) we came to the conclusion that more than 800 procedures y(-1) and per operator were necessary to reach the new lens dose limit for the three interventional specialties. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.
Duong, Phuong-Anh; Little, Brent P
2014-08-01
Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Viner, Brian J.; Jannik, Tim; Stone, Daniel
Firefighters responding to wildland fires where surface litter and vegetation contain radiological contamination will receive a radiological dose by inhaling resuspended radioactive material in the smoke. This may increase their lifetime risk of contracting certain types of cancer. Using published data, we modelled hypothetical radionuclide emissions, dispersion and dose for 70th and 97th percentile environmental conditions and for average and high fuel loads at the Savannah River Site. We predicted downwind concentration and potential dose to firefighters for radionuclides of interest ( 137Cs, 238Pu, 90Sr and 210Po). Predicted concentrations exceeded dose guidelines in the base case scenario emissions of 1.0more » × 10 7 Bq ha –1 for 238Pu at 70th percentile environmental conditions and average fuel load levels for both 4- and 14-h shifts. Under 97th percentile environmental conditions and high fuel loads, dose guidelines were exceeded for several reported cases for 90Sr, 238Pu and 210Po. Potential for exceeding dose guidelines was mitigated by including plume rise (>2 m s –1) or moving a small distance from the fire owing to large concentration gradients near the edge of the fire. As a result, our approach can quickly estimate potential dose from airborne radionuclides in wildland fire and assist decision-making to reduce firefighter exposure.« less
[State of the art and future trends in technology for computed tomography dose reduction].
Calzado Cantera, A; Hernández-Girón, I; Salvadó Artells, M; Rodríguez González, R
2013-12-01
The introduction of helical and multislice acquisitions in CT scanners together with decreased image reconstruction times has had a tremendous impact on radiological practice. Technological developments in the last 10 to 12 years have enabled very high quality images to be obtained in a very short time. Improved image quality has led to an increase in the number of indications for CT. In parallel to this development, radiation exposure in patients has increased considerably. Concern about the potential health risks posed by CT imaging, reflected in diverse initiatives and actions by official organs and scientific societies, has prompted the search for ways to reduce radiation exposure in patients without compromising diagnostic efficacy. To this end, good practice guidelines have been established, special applications have been developed for scanners, and research has been undertaken to optimize the clinical use of CT. Noteworthy technical developments incorporated in scanners include the different modes of X-ray tube current modulation, automatic selection of voltage settings, selective organ protection, adaptive collimation, and iterative reconstruction. The appropriate use of these tools to reduce radiation doses requires thorough knowledge of how they work. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.
Vano, E; Faulkner, K
2005-01-01
The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protection for cardiologists performing fluoroscopically guided procedures, will be produced during 2005. This paper highlights some of the topics of the published reports, their relevance to European legislation on medical exposures and the importance of radiation protection research in underpinning the ICRP task groups' work in to producing these documents. It is also anticipated that the results, obtained in the cardiology work package of the European research project, will be used in the new document on radiation protection for cardiologists.
NASA Astrophysics Data System (ADS)
Courageot, Estelle; Sayah, Rima; Huet, Christelle
2010-05-01
Estimating the dose distribution in a victim's body is a relevant indicator in assessing biological damage from exposure in the event of a radiological accident caused by an external source. When the dose distribution is evaluated with a numerical anthropomorphic model, the posture and morphology of the victim have to be reproduced as realistically as possible. Several years ago, IRSN developed a specific software application, called the simulation of external source accident with medical images (SESAME), for the dosimetric reconstruction of radiological accidents by numerical simulation. This tool combines voxel geometry and the MCNP(X) Monte Carlo computer code for radiation-material interaction. This note presents a new functionality in this software that enables the modelling of a victim's posture and morphology based on non-uniform rational B-spline (NURBS) surfaces. The procedure for constructing the modified voxel phantoms is described, along with a numerical validation of this new functionality using a voxel phantom of the RANDO tissue-equivalent physical model.
Courageot, Estelle; Sayah, Rima; Huet, Christelle
2010-05-07
Estimating the dose distribution in a victim's body is a relevant indicator in assessing biological damage from exposure in the event of a radiological accident caused by an external source. When the dose distribution is evaluated with a numerical anthropomorphic model, the posture and morphology of the victim have to be reproduced as realistically as possible. Several years ago, IRSN developed a specific software application, called the simulation of external source accident with medical images (SESAME), for the dosimetric reconstruction of radiological accidents by numerical simulation. This tool combines voxel geometry and the MCNP(X) Monte Carlo computer code for radiation-material interaction. This note presents a new functionality in this software that enables the modelling of a victim's posture and morphology based on non-uniform rational B-spline (NURBS) surfaces. The procedure for constructing the modified voxel phantoms is described, along with a numerical validation of this new functionality using a voxel phantom of the RANDO tissue-equivalent physical model.
Moores, B Michael
2017-06-01
A review of the role and relevance of the principles of radiation protection of the patient in diagnostic radiology as specified by ICRP has been undertaken when diagnostic risks arising from an examination are taken into account. The increase in population doses arising from diagnostic radiology over the past 20 years has been due to the widespread application of higher dose CT examinations that provide significantly more clinical information. Consequently, diagnostic risks as well as radiation risks need to be considered within the patient radiation protection framework. Justification and optimisation are discussed and the limitations imposed on patient protection by employing only a radiation risk framework is highlighted. The example of radiation protection of the patient in breast screening programmes employing mammography is used to highlight the importance of defined diagnostic outcomes in any effective radiation protection strategy. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massager, Nicolas, E-mail: nmassage@ulb.ac.be; Neurosurgery-Department, Hospital Erasme, Brussels; Lonneville, Sarah
2011-11-15
Objectives: We investigated variations in the distribution of radiation dose inside (dose inhomogeneity) and outside (dose falloff) the target volume during Gamma Knife (GK) irradiation of vestibular schwannoma (VS). We analyzed the relationship between some parameters of dose distribution and the clinical and radiological outcome of patients. Methods and Materials: Data from dose plans of 203 patients treated for a vestibular schwannoma by GK C using same prescription dose (12 Gy at the 50% isodose) were collected. Four different dosimetric indexes were defined and calculated retrospectively in all plannings on the basis of dose-volume histograms: Paddick conformity index (PI), gradientmore » index (GI), homogeneity index (HI), and unit isocenter (UI). The different measures related to distribution of the radiation dose were compared with hearing and tumor outcome of 203 patients with clinical and radiological follow-up of minimum 2 years. Results: Mean, median, SD, and ranges of the four indexes of dose distribution analyzed were calculated; large variations were found between dose plans. We found a high correlation between the target volume and PI, GI, and UI. No significant association was found between the indexes of dose distribution calculated in this study and tumor control, tumor volume shrinkage, hearing worsening, loss of functional hearing, or complete hearing loss at last follow-up. Conclusions: Parameters of distribution of the radiation dose during GK radiosurgery for VS can be highly variable between dose plans. The tumor and hearing outcome of patients treated is not significantly related to these global indexes of dose distribution inside and around target volume. In GK radiosurgery for VS, the outcome seems more to be influenced by local radiation dose delivered to specific structures or volumes than by global dose gradients.« less
Ocular allergy modulation to hi-dose antigen sensitization is a Treg-dependent process.
Lee, Hyun Soo; Schlereth, Simona; Khandelwal, Payal; Saban, Daniel R
2013-01-01
A reproducible method to inhibit allergic immune responses is accomplished with hi-dose Ag sensitization, via intraperitoneal (IP) injection. However, the role of CD4+ CD25+ FoxP3+ T regulatory cells (Treg) in this process is unknown, as is whether such modulation extends to ocular allergy. We therefore determined herein whether hi-dose sensitization modulates ocular allergy, and whether CD4+ CD25+ FoxP3+ Treg are involved. C57BL/6 mice were IP sensitized via low-dose (100 µg) versus hi-dose (1000 µg) ovalbumin (OVA), in aluminum hydroxide (1 mg) and pertussis-toxin (300 ng). Other mice received anti-CD25 Ab (PC61) to ablate Treg during sensitization. In another experiment, Treg from hi-dose sensitized mice were adoptively transferred into low-dose sensitized mice. Once daily OVA challenges were administered. Clinical signs, IgE, T cell cytokines, and eosinophils were assessed. Data revealed that hi-dose, but not low-dose, sensitization led to allergy modulation, indicated by decreased clinical signs, serum IgE levels, Th2 recall responses, and eosinophil recruitment. T cells from hi-dose sensitized mice showed a robust increase in TGF-b production, and Treg from these mice were able to efficiently suppress effector T cell proliferation in vitro. In addition, in vivo Treg ablation in hi-dose sensitized mice revoked allergy modulation. Lastly, Treg from hi-dose sensitized mice were able to adoptively transfer allergy modulation to their low-dose sensitized counterparts. Collectively, these findings indicate that modulation to hi-dose sensitization, which is extended to ocular allergy, occurs in a Treg-dependent manner. In addition, our data suggest that hi-dose sensitization may henceforth facilitate the further examination of CD4+ CD25+ FoxP3+ Treg in allergic disease.
Evolution of the Radiological Protection System and its Implementation.
Lazo, Edward
2016-02-01
The International System of Radiological Protection, developed, maintained, and elaborated by the International Commission on Radiological Protection (ICRP) has, for the past 50 y, provided a robust framework for developing radiological protection policy, regulation, and application. It has, however, been evolving as a result of experience with its implementation, modernization of social awareness of a shrinking world where the Internet links everyone instantly, and increasing public interest in safety-related decisions. These currents have gently pushed the ICRP in recent years to focus more sharply on particular aspects of its system: optimization, prevailing circumstances, the use of effective dose and aspects of an individual's risk, and consideration of the independent implementation of the international system's elements. This paper will present these issues and their relevance to the ICRP system of protection and its evolution. The broader framework of radiological protection (e.g., science, philosophy, policy, regulation, implementation), of which the ICRP is an important element, will provide a global, equally evolving context for this characterization of the changing ICRP system of radiological protection.
NASA Astrophysics Data System (ADS)
Setiawan, B.; Prihastuti, S.; Moersidik, S. S.
2018-02-01
The operational of near surface disposal facility during waste packages loading activity into the facility, or in a monitoring activity around disposal facility at Karawang area is predicted to give a radiological risk to radiation workers. The thickness of disposal facility cover system affected the number of radiological risk of workers. Due to this reason, a radiological risk estimation needs to be considered. RESRAD onsite code is applied for this purpose by analyse the individual accepted dose and radiological risk data of radiation workers. The obtained results and then are compared with radiation protection reference in accordance with national regulation. In this case, the data from the experimental result of Karawang clay as host of disposal facility such as Kd value of 137Cs was used. Results showed that the thickness of the cover layer of disposal facility affected to the radiological risk which accepted by workers in a near surface disposal facility.
Mazziotti, G; Mormando, M; Cristiano, A; Bianchi, A; Porcelli, T; Giampietro, A; Maffezzoni, F; Serra, V; De Marinis, L; Giustina, A
2014-06-01
In this study, we aimed at evaluating the association between radiological vertebral fractures and levo-thyroxine (l-T4) replacement doses in adult patients with hypopituitarism. Cross-sectional study. We studied 74 adult hypopituitary patients (males, 43; females, 31; mean age, 57 years; and range, 23-79) with central hypothyroidism treated with l-T4 (median daily dose: 1.1 μg/kg). All patients also had severe GH deficiency (GHD) and 38 of them were replaced with recombinant GH. Vertebral fractures were assessed by a quantitative morphometric analysis performed on thoracic and lumbar spine lateral X-ray. Radiological vertebral fractures were found in 23 patients (31.1%) in association with untreated GHD (P=0.02), higher serum free T4 levels (P=0.03), a higher daily dose of l-T4 (P=0.005), and a longer duration of hypopituitarism (P=0.05). When GHD was treated, the prevalence of vertebral fractures was more frequent (P=0.03) in patients receiving high l-T4 doses (third tertile: >1.35 μg/kg per day) as compared with patients who were treated with lower drug doses (first tertile: <0.93 μg/kg per day). Such a difference was not observed in patients with untreated GHD who showed a higher prevalence of vertebral fractures regardless of l-T4 daily doses. Multivariate analysis showed that untreated GHD (odds ratio: 4.27, 95% CI 1.27-14.33; P=0.01) and the daily dose of l-T4 (odds ratio: 4.01, 95% CI 1.16-14.39; P=0.03) maintained a significant and independent association with vertebral fractures in patients with central hypothyroidism. Our data suggest for the first time that a relative overtreatment with l-T4 may influence the fracture risk in some patients with hypopituitarism. © 2014 European Society of Endocrinology.
SU-D-209-03: Radiation Dose Reduction Using Real-Time Image Processing in Interventional Radiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kanal, K; Moirano, J; Zamora, D
Purpose: To characterize changes in radiation dose after introducing a new real-time image processing technology in interventional radiology systems. Methods: Interventional radiology (IR) procedures are increasingly complex, at times requiring substantial time and radiation dose. The risk of inducing tissue reactions as well as long-term stochastic effects such as radiation-induced cancer is not trivial. To reduce this risk, IR systems are increasingly equipped with dose reduction technologies.Recently, ClarityIQ (Philips Healthcare) technology was installed in our existing neuroradiology IR (NIR) and vascular IR (VIR) suites respectively. ClarityIQ includes real-time image processing that reduces noise/artifacts, enhances images, and sharpens edges while alsomore » reducing radiation dose rates. We reviewed 412 NIR (175 pre- and 237 post-ClarityIQ) procedures and 329 VIR (156 preand 173 post-ClarityIQ) procedures performed at our institution pre- and post-ClarityIQ implementation. NIR procedures were primarily classified as interventional or diagnostic. VIR procedures included drain port, drain placement, tube change, mesenteric, and implanted venous procedures. Air Kerma (AK in units of mGy) was documented for all the cases using a commercial radiation exposure management system. Results: When considering all NIR procedures, median AK decreased from 1194 mGy to 561 mGy. When considering all VIR procedures, median AK decreased from 49 to 14 mGy. Both NIR and VIR exhibited a decrease in AK exceeding 50% after ClarityIQ implementation, a statistically significant (p<0.05) difference. Of the 5 most common VIR procedures, all median AK values decreased, but significance (p<0.05) was only reached in venous access (N=53), angio mesenteric (N=41), and drain placement procedures (N=31). Conclusion: ClarityIQ can reduce dose significantly for both NIR and VIR procedures. Image quality was not assessed in conjunction with the dose reduction.« less
Paolicchi, Fabio; Faggioni, Lorenzo; Bastiani, Luca; Molinaro, Sabrina; Puglioli, Michele; Caramella, Davide; Bartolozzi, Carlo
2014-06-01
The purpose of this study was to assess the radiation dose and image quality of pediatric head CT examinations before and after radiologic staff training. Outpatients 1 month to 14 years old underwent 215 unenhanced head CT examinations before and after intensive training of staff radiologists and technologists in optimization of CT technique. Patients were divided into three age groups (0-4, 5-9, and 10-14 years), and CT dose index, dose-length product, tube voltage, and tube current-rotation time product values before and after training were retrieved from the hospital PACS. Gray matter conspicuity and contrast-to-noise ratio before and after training were calculated, and subjective image quality in terms of artifacts, gray-white matter differentiation, noise, visualization of posterior fossa structures, and need for repeat CT examination was visually evaluated by three neuroradiologists. The median CT dose index and dose-length product values were significantly lower after than before training in all age groups (27 mGy and 338 mGy ∙ cm vs 107 mGy and 1444 mGy ∙ cm in the 0- to 4-year-old group, 41 mGy and 483 mGy ∙ cm vs 68 mGy and 976 mGy ∙ cm in the 5- to 9-year-old group, and 51 mGy and 679 mGy ∙ cm vs 107 mGy and 1480 mGy ∙ cm in the 10- to 14-year-old group; p < 0.001). The tube voltage and tube current-time values after training were significantly lower than the levels before training (p < 0.001). Subjective posttraining image quality was not inferior to pretraining levels for any item except noise (p < 0.05), which, however, was never diagnostically unacceptable. Radiologic staff training can be effective in reducing radiation dose while preserving diagnostic image quality in pediatric head CT examinations.
Heavy Metal Pad Shielding during Fluoroscopic Interventions
Dromi, Sergio; Wood, Bradford J.; Oberoi, Jay; Neeman, Ziv
2008-01-01
Significant direct and scatter radiation doses to patient and physician may result from routine interventional radiology practice. A lead-free disposable tungsten antimony shielding pad was tested in phantom patients during simulated diagnostic angiography procedures. Although the exact risk of low doses of ionizing radiation is unknown, dramatic dose reductions can be seen with routine use of this simple, sterile pad made from lightweighttungsten antimony material. PMID:16868175
Wang, Y; Lin, D; Fu, T
1997-03-01
Morphology of inorganic material powders before and after being treated by ultrafine crush was observed by transformite electron microscope. The length and diameter of granules were measured. Polymers inorganic material powders before and after being treated by ultrafine crush were used for preparing radiological equivalent materials. Blending compatibility of inorganic meterials with polymer materials was observed by scanning electron microscope. CT values of tissue equivalent materials were measured by X-ray CT. Distribution of inorganic materials was examined. The compactness of materials was determined by the water absorbed method. The elastic module of materials was measured by laser speckle interferementry method. The results showed that the inorganic material powders treated by the ultrafine crush blent well with polymer and the distribution of these powders in the polymer was homogeneous. The equivalent errors of linear attenuation coefficients and CT values of equivalent materials were small. Their elastic modules increased one order of magnitude from 6.028 x 10(2) kg/cm2 to 9.753 x 10(3) kg/cm2. In addition, the rod inorganic material powders having rod granule blent easily with polymer. The present study provides a theoretical guidance and experimental basis for the design and synthesis of radiological equivalent materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LePoire, D.; Arnish, J.; Cheng, J.J.
NRC licensees at decommissioning nuclear facilities submit License Termination Plans (LTP) or Decommissioning Plans (DP) to NRC for review and approval. To facilitate a uniform and consistent review of these plans, the NRC developed training for its staff. A live classroom course was first developed in 2005, which targeted specific aspects of the LTP and DP review process related to dose-based compliance demonstrations or modeling. A web-based training (WBT) course is being developed in 2006 to replace the classroom-based course. The advantage of the WBT is that it will allow for staff training or refreshers at any time, while themore » advantage of a classroom-based course is that it provides a forum for lively discussion and the sharing of experience of classroom participants. The training course consists of the core and advanced modules tailored to specific NRC job functions. Topics for individual modules include identifying the characteristics of simple and complex sites, identifying when outside expertise or consultation is needed, demonstrating how to conduct acceptance and technical reviews of dose modeling, and providing details regarding the level of justification needed for realistic scenarios for both dose modeling and derivation of DCGLs. Various methods of applying probabilistic uncertainty analysis to demonstrate compliance with dose-based requirements are presented. These approaches include 1) modeling the pathways of radiological exposure and estimating doses to receptors from a combination of contaminated media and radionuclides, and 2) using probabilistic analysis to determine an appropriate set of input parameters to develop derived concentration guideline limits or DCGLs (DCGLs are media- and nuclide-specific concentration limits that will meet dose-based, license termination rule criteria found in 10 CFR Part 20, Subpart E). Calculation of operational (field) DCGL's from media- and nuclide-specific DCGLs and use of operational DCGLs in conducting final status surveys are addressed in the WBT. Realistic case examples are presented and analyzed including the abstraction of a realistic site into a conceptual model and computer model. A case history is also used to demonstrate development of NRC review documents such as requests for additional information (RAIs). To enhance the web-based training experience, audio, animations, linked documents, quizzes, and scripts are being integrated with a commercial web-based training package that supports simple navigation. The course is also being integrated into both existing and state-of-the-art learning management systems. A testing group is being utilized to identify and help resolve training issues prior to deployment of the course. When completed, the course can be accessed for credited training with required modules dependent on the job category of the training participant. The modules will also be accessible to NRC staff for review or refresher following initial course completion. WBT promotes consistency in reviews and has the advantage of being able to be used as a resource to staff at any time. The WBT will provide reviewers with knowledge needed to perform risk-informed analyses (e.g., information related to development of realistic scenarios and use of probabilistic analysis). WBT on review of LTP or DP dose modeling will promote staff development, efficiency, and effectiveness in performing risk-informed, performance-based reviews of decommissioning activities at NRC-licensed facilities. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
A companion report, DOE/ET-0064/1, presents a geographic, cultural, and demographic profile of the Tennessee Valley Region study area. This report describes the calculations of radionuclide release and transport and of the resultant dose to the regional population, assuming a projected installed capacity of 220,000 MW in the year 2000, of which 144,000 MW would be nuclear. All elements of the fuel cycle were assumed to be in operation. The radiological dose was calculated as a one-year dose based on ingestion of 35 different food types as well as for nine non-food pathways, and was reported as dose to the totalmore » body and for six specific organs for each of four age groups (infant, child, teen, and adult). Results indicate that the average individual would receive an incremental dose of 7 x 10/sup -4/ millirems in the year 2000 from the operation of nuclear facilities within and adjacent to the region, five orders of magnitude smaller than the dose from naturally occurring radiation in the area. The major contributor to dose was found to be tritium, and the most significant pathways were immersion in air, inhalation of air, transpiration of tritium (absorption through the skin), and exposure radionuclide-containing soil. 60 references.« less
Stagich, Brooke H; Moore, Kelsey R; Newton, Joseph R; Dixon, Kenneth L; Jannik, G Timothy
2017-04-01
Most U.S. Department of Energy (DOE) facilities with radiological airborne releases use the U.S. Environmental Protection Agency's (EPA) environmental dosimetry code CAP88-PC to demonstrate compliance with regulations in 40CFR61, subpart H [National Emission Standards for Hazardous Air Pollutants: Radiological (NESHAP)]. In 2015, EPA released Version 4 of CAP88-PC, which included significant modifications that improved usability and age-dependent dose coefficients and usage factors for six age groups (infant, 1 y, 5 y, 10 y, 15 y, and adult). However, EPA has not yet provided specific guidance on how to use these age-dependent factors. For demonstrating compliance with DOE public dose regulations, the Savannah River Site (SRS) recently changed from using the maximally exposed individual (MEI) concept (adult male) to the representative person concept (age- and gender-averaged reference person). In this study, dose comparisons are provided between the MEI and a SRS-specific representative person using the age-specific dose coefficients and usage factors in CAP88-PC V.4. Dose comparisons also are provided for each of the six age groups using five radionuclides of interest at SRS (tritium oxide, Cs, Sr, Pu, and I). In general, the total effective dose increases about 11% for the representative person as compared to the current NESHAP MEI because of the inclusion of the more radiosensitive age groups.
Viner, Brian J.; Jannik, Tim; Stone, Daniel; ...
2015-06-12
Firefighters responding to wildland fires where surface litter and vegetation contain radiological contamination will receive a radiological dose by inhaling resuspended radioactive material in the smoke. This may increase their lifetime risk of contracting certain types of cancer. Using published data, we modelled hypothetical radionuclide emissions, dispersion and dose for 70th and 97th percentile environmental conditions and for average and high fuel loads at the Savannah River Site. We predicted downwind concentration and potential dose to firefighters for radionuclides of interest ( 137Cs, 238Pu, 90Sr and 210Po). Predicted concentrations exceeded dose guidelines in the base case scenario emissions of 1.0more » × 10 7 Bq ha –1 for 238Pu at 70th percentile environmental conditions and average fuel load levels for both 4- and 14-h shifts. Under 97th percentile environmental conditions and high fuel loads, dose guidelines were exceeded for several reported cases for 90Sr, 238Pu and 210Po. Potential for exceeding dose guidelines was mitigated by including plume rise (>2 m s –1) or moving a small distance from the fire owing to large concentration gradients near the edge of the fire. As a result, our approach can quickly estimate potential dose from airborne radionuclides in wildland fire and assist decision-making to reduce firefighter exposure.« less
Radiological assessment for bauxite mining and alumina refining.
O'Connor, Brian H; Donoghue, A Michael; Manning, Timothy J H; Chesson, Barry J
2013-01-01
Two international benchmarks assess whether the mining and processing of ores containing Naturally Occurring Radioactive Material (NORM) require management under radiological regulations set by local jurisdictions. First, the 1 Bq/g benchmark for radionuclide head of chain activity concentration determines whether materials may be excluded from radiological regulation. Second, processes may be exempted from radiological regulation where occupational above-background exposures for members of the workforce do not exceed 1 mSv/year. This is also the upper-limit of exposure prescribed for members of the public. Alcoa of Australia Limited (Alcoa) has undertaken radiological evaluations of the mining and processing of bauxite from the Darling Range of Western Australia since the 1980s. Short-term monitoring projects have demonstrated that above-background exposures for workers do not exceed 1 mSv/year. A whole-of-year evaluation of above-background, occupational radiological doses for bauxite mining, alumina refining and residue operations was conducted during 2008/2009 as part of the Alcoa NORM Quality Assurance System (NQAS). The NQAS has been guided by publications from the International Commission on Radiological Protection (ICRP), the International Atomic Energy Agency (IAEA) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). The NQAS has been developed specifically in response to implementation of the Australian National Directory on Radiation Protection (NDRP). Positional monitoring was undertaken to increase the accuracy of natural background levels required for correction of occupational exposures. This is important in view of the small increments in exposure that occur in bauxite mining, alumina refining and residue operations relative to natural background. Positional monitoring was also undertaken to assess the potential for exposure in operating locations. Personal monitoring was undertaken to characterise exposures in Similar Exposure Groups (SEGs). The monitoring was undertaken over 12 months, to provide annual average assessments of above-background doses, thereby reducing temporal variations, especially for radon exposures. The monitoring program concentrated on gamma and radon exposures, rather than gross alpha exposures, as past studies have shown that gross alpha exposures from inhalable dust for most of the workforce are small in comparison to combined gamma and radon exposures. The natural background determinations were consistent with data in the literature for localities near Alcoa's mining, refining and residue operations in Western Australia, and also with UNSCEAR global data. Within the mining operations, there was further consistency between the above-background dose estimates and the local geochemistry, with slight elevation of dose levels in mining pits. Conservative estimates of above-background levels for the workforce have been made using an assumption of 100% occupancy (1920 hours per year) for the SEGs considered. Total incremental composite doses for individuals were clearly less than 1.0 mSv/year when gamma, radon progeny and gross alpha exposures were considered. This is despite the activity concentration of some materials being slightly higher than the benchmark of 1 Bq/g. The results are consistent with previous monitoring and demonstrate compliance with the 1 mSv/year exemption level within mining, refining and residue operations. These results will be of value to bauxite mines and alumina refineries elsewhere in the world.
[High-contrast resolution of film-screen systems in oral and maxillofacial radiology].
Kaeppler, G; Reinert, S
2007-11-01
The aim was to determine differences in high-contrast resolution of film-screen systems used in dental panoramic and cephalometric radiography by calculating the modulation transfer function (MTF). The radiographs used to determine the MTF should be taken by the same x-ray units as those used for patient radiographs. The MTF was determined using a lead grid and according to DIN 6867-2 for 11 film-screen systems (speed 250, speed class 200 and 400) used in dental radiographic diagnostics. The optical density was measured using a microdensitometer developed by PTB. With 10% of the modulation transfer factor, newly developed film-screen systems (speed class 200 and 400) demonstrated a resolution of 4.9 to 6 line pairs per mm (panoramic radiography). In cephalometric radiography a film-screen system (speed class 400 and green-sensitive film) had a resolution of 4.2 line pairs per mm and surpassed two film-screen systems (speed class 400, resolution of 3 line pairs per mm, blue-sensitive films). The relevance of this study is underlined by the diagnostic reference doses defined in the German X-ray Ordinance (RöV) which are also intended for dentistry. Film-screen systems (speed 250, speed class 200) previously used in dental panoramic and cephalometric radiography can be replaced by newly developed film-screen systems (speed class 400). In dental radiography dose reductions are possible with film-screen systems (speed class 400) without impairing diagnostic accuracy. The introduction of newly developed film-screen systems (speed class 400) requires lower milliampere-seconds and therefore an adjustment of the x-ray units to lower milliampere settings.
Automated extraction of radiation dose information for CT examinations.
Cook, Tessa S; Zimmerman, Stefan; Maidment, Andrew D A; Kim, Woojin; Boonn, William W
2010-11-01
Exposure to radiation as a result of medical imaging is currently in the spotlight, receiving attention from Congress as well as the lay press. Although scanner manufacturers are moving toward including effective dose information in the Digital Imaging and Communications in Medicine headers of imaging studies, there is a vast repository of retrospective CT data at every imaging center that stores dose information in an image-based dose sheet. As such, it is difficult for imaging centers to participate in the ACR's Dose Index Registry. The authors have designed an automated extraction system to query their PACS archive and parse CT examinations to extract the dose information stored in each dose sheet. First, an open-source optical character recognition program processes each dose sheet and converts the information to American Standard Code for Information Interchange (ASCII) text. Each text file is parsed, and radiation dose information is extracted and stored in a database which can be queried using an existing pathology and radiology enterprise search tool. Using this automated extraction pipeline, it is possible to perform dose analysis on the >800,000 CT examinations in the PACS archive and generate dose reports for all of these patients. It is also possible to more effectively educate technologists, radiologists, and referring physicians about exposure to radiation from CT by generating report cards for interpreted and performed studies. The automated extraction pipeline enables compliance with the ACR's reporting guidelines and greater awareness of radiation dose to patients, thus resulting in improved patient care and management. Copyright © 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Air pathway effects of nuclear materials production at the Hanford Site, 1983 to 1992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patton, G.W.; Cooper, A.T.
1993-10-01
This report describes the air pathway effects of Hanford Site operations from 1983 to 1992 on the local environment by summarizing the air concentrations of selected radionuclides at both onsite and offsite locations, comparing trends in environment concentrations to changing facility emissions, and briefly describing trends in the radiological dose to the hypothetical maximally exposed member of the public. The years 1983 to 1992 represent the last Hanford Site plutonium production campaign, and this report deals mainly with the air pathway effects from the 200 Areas, in which the major contributors to radiological emissions were located. An additional purpose formore » report was to review the environmental data for a long period of time to provide insight not available in an annual report format. The sampling and analytical systems used by the Surface Environmental Surveillance Project (SESP) to collect air samples during the period of this report were sufficiently sensitive to observe locally elevated concentrations of selected radionuclides near onsite source of emission as well as observing elevated levels, compared to distant locations, of some radionuclides at the down wind perimeter. The US DOE Derived Concentration Guides (DCGs) for airborne radionuclides were not exceeded for any air sample collected during 1983 to 1992, with annual average concentrations of all radionuclides at the downwind perimeter being considerably below the DCG values. Air emissions at the Hanford Site during the period of this report were dominated by releases from the PUREX Plant, with {sup 85}Kr being the major release on a curie basis and {sup 129}I being the major release on a radiological dose basis. The estimated potential radiological dose from Hanford Site point source emissions to the hypothetical maximally exposed individual (MEI) ranged from 0. 02 to 0.22 mrem/yr (effective dose equivalent), which is well below the DOE radiation limit to the public of 100 mrem/yr.« less
Pinto, A; Selvaggi, S; Sicignano, G; Vollono, E; Iervolino, L; Amato, F; Molinari, A; Grassi, R
2008-02-01
E-learning, an abbreviation of electronic learning, indicates the provision of education and training on the Internet or the World Wide Web. The impact of networks and the Internet on radiology is undoubtedly important, as it is for medicine as a whole. The Internet offers numerous advantages compared with other mass media: it provides access to a large amount of information previously known only to individual specialists; it is flexible, permitting the use of images or video; and it allows linking to Web sites on a specific subject, thus contributing to further expand knowledge. Our purpose is to illustrate the regulatory aspects (including Internet copyright laws), current radiological applications and future prospects of e-learning. Our experience with the installation of an e-learning platform is also presented. We performed a PubMed search on the published literature (without time limits) dealing with e-learning tools and applications in the health sector with specific reference to radiology. The search included all study types in the English language with the following key words: e-learning, education, teaching, online exam, radiology and radiologists. The Fiaso study was referred to for the regulatory aspects of e-learning. The application of e-learning to radiology requires the development of a model that involves selecting and creating e-learning platforms, creating and technologically adapting multimedia teaching modules, creating and managing a unified catalogue of teaching modules, planning training actions, defining training pathways and Continuing Education in Medicine (CME) credits, identifying levels of teaching and technological complexity of support tools, sharing an organisational and methodological model, training the trainers, operators' participation and relational devices, providing training, monitoring progress of the activities, and measuring the effectiveness of training. Since 2004, a platform--LiveLearning--has been used at our university: this is a Web-oriented application, that is, an Internet software solution that users can access through a Web browser. The pages displayed by the browser are dynamically generated through interaction with a database that collects both data required for the application to work and data related to the courses provided. There are different approaches to developing applications that use databases to store information. The selected approach is based on a modular three-level architecture divided into presentation level, intermediate level, and data level. The LiveLearning platform includes modules to manage multimedia contents and to interface with the streaming server so that the student can access the training contents directly from the platform interfaces. Furthermore, the platform offers its users different modules: Teaching Units, Documents, Forums, and Chats. By appropriately combining these modules, customised training can be devised based on specific requirements. The increasing diffusion of continuous education will reduce the costs of e-learning and make this training method, which helps keep pace with technological progress, more attractive, with significant professional gains for radiologists.
Current Trends in Heparin Use During Arterial Vascular Interventional Radiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durran, Alexandra C., E-mail: durranjobs@hotmail.com; Watts, Christopher, E-mail: Christopher.watts@salisbury.nhs.uk
2012-12-15
Purpose: This study was designed to assess the current use of heparinized saline and bolus doses of heparin in non-neurological interventional radiology and to determine whether consensus could be reached to produce guidance for heparin use during arterial vascular intervention. Methods: An interactive electronic questionnaire was distributed to members of the British Society of Interventional Radiology regarding their current practice in the use, dosage, and timing of heparin boluses and heparinized flushing solutions.ResultsA total of 108 completed questionnaires were received. More than 80% of respondents used heparinized saline with varying concentrations; the most prevalent was 1,000 IU/l (international units ofmore » heparin per liter) and 5,000 IU/l. Fifty-one percent of interventionalists use 3,000 IU as their standard bolus dose; however, the respondents were split regarding the timing of bolus dose with {approx}60% administering it after arterial access is obtained and 40% after crossing the lesion. There was no consensus on altering dose according to body weight, and only 4% monitored clotting parameters. Conclusions: There seems to be some coherence among practicing interventionalists regarding heparin administration. We hypothesize that heparinized saline should be used at a recognized standard concentration of 1,000 IU/l as a flushing concentration in all arterial vascular interventions and that 3,000 IU bolus is considered the standard dose for straightforward therapeutic procedures and 5000 IU for complex, crural, and endovascular aneurysm repair work. The bolus should be given after arterial access is obtained to allow time for optimal anticoagulation to be achieved by the time of active intervention and stenting. Further research into clotting abnormalities following such interventional procedures would be an interesting quantifiable follow-up to this initial survey of opinions and practice.« less
Importance of establishing radiation protection culture in Radiology Department.
Ploussi, Agapi; Efstathopoulos, Efstathios P
2016-02-28
The increased use of ionization radiation for diagnostic and therapeutic purposes, the rapid advances in computed tomography as well as the high radiation doses delivered by interventional procedures have raised serious safety and health concerns for both patients and medical staff and have necessitated the establishment of a radiation protection culture (RPC) in every Radiology Department. RPC is a newly introduced concept. The term culture describes the combination of attitudes, beliefs, practices and rules among the professionals, staff and patients regarding to radiation protection. Most of the time, the challenge is to improve rather than to build a RPC. The establishment of a RPC requires continuing education of the staff and professional, effective communication among stakeholders of all levels and implementation of quality assurance programs. The RPC creation is being driven from the highest level. Leadership, professionals and associate societies are recognized to play a vital role in the embedding and promotion of RPC in a Medical Unit. The establishment of a RPC enables the reduction of the radiation dose, enhances radiation risk awareness, minimizes unsafe practices, and improves the quality of a radiation protection program. The purpose of this review paper is to describe the role and highlight the importance of establishing a strong RPC in Radiology Departments with an emphasis on promoting RPC in the Interventional Radiology environment.
NASA Astrophysics Data System (ADS)
Sasaki, Syota; Yamada, Tadashi; Yamada, Tomohito J.
2014-05-01
We aim to propose a kinematic-based methodology similar with runoff analysis for readily understandable radiological protection. A merit of this methodology is to produce sufficiently accurate effective doses by basic analysis. The great earthquake attacked the north-east area in Japan on March 11, 2011. The system of electrical facilities to control Fukushima Daiichi nuclear power plant was completely destroyed by the following tsunamis. From the damaged reactor containment vessels, an amount of radioactive isotopes had leaked and been diffused in the vicinity of the plant. Radiological internal exposure caused by ingestion of food containing radioactive isotopes has become an issue of great interest to the public, and has caused excessive anxiety because of a deficiency of fundamental knowledge concerning radioactivity. Concentrations of radioactivity in the human body and internal exposure have been studied extensively. Previous radiologic studies, for example, studies by International Commission on Radiological Protection(ICRP), employ a large-scale computational simulation including actual mechanism of metabolism in the human body. While computational simulation is a standard method for calculating exposure doses among radiology specialists, these methods, although exact, are too difficult for non-specialists to grasp the whole image owing to the sophistication. In this study, the human body is treated as a vessel. The number of radioactive atoms in the human body can be described by an equation of continuity, which is the only governing equation. Half-life, the period of time required for the amount of a substance decreases by half, is only parameter to calculate the number of radioactive isotopes in the human body. Half-life depends only on the kinds of nuclides, there are no arbitrary parameters. It is known that the number of radioactive isotopes decrease exponentially by radioactive decay (physical outflow). It is also known that radioactive isotopes decrease exponentially by excretion (biological outflow). The total outflow is the sum of physical outflow and biological outflow. As a result, the number of radioactive atoms in the human body also decreases exponentially. Half-life can be determined by outflow flux from the definition. Intensity of radioactivity is linear respect to the number of radioactive atoms, both are equivalent analytically. Internal total exposure can be calculated by the time integral of intensity of radioactivity. The absorbed energy into the human body per radioactive decay and the effective dose are calculated by aid of Fermi's theory of beta decay and special relativity. The effective doses calculated by the present method almost agree with those of a study by ICRP. The present method shows that standard limit in general foods for radioactive cesium enforced in Japan, 100 Bq/kg, is too excessive. When we eat foods which contain cesium-137 of 100 Bq/kg at 1 kg/d during 50 years, we receive the effective dose less than natural exposure. Similarly, it is shown that we cannot find significant health damage medically and statistically by ingestion of rice which is harvested from a paddy field deposited current (January, 2014) radioactive cesium.
Rosenkrantz, Andrew B; Doshi, Ankur M
2016-01-01
To assess information regarding radiology practices on public transparency Web sites. Eight Web sites comparing radiology centers' price and quality were identified. Web site content was assessed. Six of eight Web sites reported examination prices. Other reported information included hours of operation (4/8), patient satisfaction (2/8), American College of Radiology (ACR) accreditation (3/8), on-site radiologists (2/8), as well as parking, accessibility, waiting area amenities, same/next-day reports, mammography follow-up rates, examination appropriateness, radiation dose, fellowship-trained radiologists, and advanced technologies (1/8 each). Transparency Web sites had a preponderance of price (and to a lesser extent service quality) information, risking fostering price-based competition at the expense of clinical quality. Copyright © 2016 Elsevier Inc. All rights reserved.
Fast skin dose estimation system for interventional radiology
Takata, Takeshi; Kotoku, Jun’ichi; Maejima, Hideyuki; Kumagai, Shinobu; Arai, Norikazu; Kobayashi, Takenori; Shiraishi, Kenshiro; Yamamoto, Masayoshi; Kondo, Hiroshi; Furui, Shigeru
2018-01-01
Abstract To minimise the radiation dermatitis related to interventional radiology (IR), rapid and accurate dose estimation has been sought for all procedures. We propose a technique for estimating the patient skin dose rapidly and accurately using Monte Carlo (MC) simulation with a graphical processing unit (GPU, GTX 1080; Nvidia Corp.). The skin dose distribution is simulated based on an individual patient’s computed tomography (CT) dataset for fluoroscopic conditions after the CT dataset has been segmented into air, water and bone based on pixel values. The skin is assumed to be one layer at the outer surface of the body. Fluoroscopic conditions are obtained from a log file of a fluoroscopic examination. Estimating the absorbed skin dose distribution requires calibration of the dose simulated by our system. For this purpose, a linear function was used to approximate the relation between the simulated dose and the measured dose using radiophotoluminescence (RPL) glass dosimeters in a water-equivalent phantom. Differences of maximum skin dose between our system and the Particle and Heavy Ion Transport code System (PHITS) were as high as 6.1%. The relative statistical error (2 σ) for the simulated dose obtained using our system was ≤3.5%. Using a GPU, the simulation on the chest CT dataset aiming at the heart was within 3.49 s on average: the GPU is 122 times faster than a CPU (Core i7–7700K; Intel Corp.). Our system (using the GPU, the log file, and the CT dataset) estimated the skin dose more rapidly and more accurately than conventional methods. PMID:29136194
Fast skin dose estimation system for interventional radiology.
Takata, Takeshi; Kotoku, Jun'ichi; Maejima, Hideyuki; Kumagai, Shinobu; Arai, Norikazu; Kobayashi, Takenori; Shiraishi, Kenshiro; Yamamoto, Masayoshi; Kondo, Hiroshi; Furui, Shigeru
2018-03-01
To minimise the radiation dermatitis related to interventional radiology (IR), rapid and accurate dose estimation has been sought for all procedures. We propose a technique for estimating the patient skin dose rapidly and accurately using Monte Carlo (MC) simulation with a graphical processing unit (GPU, GTX 1080; Nvidia Corp.). The skin dose distribution is simulated based on an individual patient's computed tomography (CT) dataset for fluoroscopic conditions after the CT dataset has been segmented into air, water and bone based on pixel values. The skin is assumed to be one layer at the outer surface of the body. Fluoroscopic conditions are obtained from a log file of a fluoroscopic examination. Estimating the absorbed skin dose distribution requires calibration of the dose simulated by our system. For this purpose, a linear function was used to approximate the relation between the simulated dose and the measured dose using radiophotoluminescence (RPL) glass dosimeters in a water-equivalent phantom. Differences of maximum skin dose between our system and the Particle and Heavy Ion Transport code System (PHITS) were as high as 6.1%. The relative statistical error (2 σ) for the simulated dose obtained using our system was ≤3.5%. Using a GPU, the simulation on the chest CT dataset aiming at the heart was within 3.49 s on average: the GPU is 122 times faster than a CPU (Core i7-7700K; Intel Corp.). Our system (using the GPU, the log file, and the CT dataset) estimated the skin dose more rapidly and more accurately than conventional methods.
A method to reduce patient's eye lens dose in neuro-interventional radiology procedures
NASA Astrophysics Data System (ADS)
Safari, M. J.; Wong, J. H. D.; Kadir, K. A. A.; Sani, F. M.; Ng, K. H.
2016-08-01
Complex and prolonged neuro-interventional radiology procedures using the biplane angiography system increase the patient's risk of radiation-induced cataract. Physical collimation is the most effective way of reducing the radiation dose to the patient's eye lens, but in instances where collimation is not possible, an attenuator may be useful in protecting the eyes. In this study, an eye lens protector was designed and fabricated to reduce the radiation dose to the patients' eye lens during neuro-interventional procedures. The eye protector was characterised before being tested on its effectiveness in a simulated aneurysm procedure on an anthropomorphic phantom. Effects on the automatic dose rate control (ADRC) and image quality are also evaluated. The eye protector reduced the radiation dose by up to 62.1% at the eye lens. The eye protector is faintly visible in the fluoroscopy images and increased the tube current by a maximum of 3.7%. It is completely invisible in the acquisition mode and does not interfere with the clinical procedure. The eye protector placed within the radiation field of view was able to reduce the radiation dose to the eye lens by direct radiation beam of the lateral x-ray tube with minimal effect on the ADRC system.
Diagnostic x-ray dosimetry using Monte Carlo simulation.
Ioppolo, J L; Price, R I; Tuchyna, T; Buckley, C E
2002-05-21
An Electron Gamma Shower version 4 (EGS4) based user code was developed to simulate the absorbed dose in humans during routine diagnostic radiological procedures. Measurements of absorbed dose using thermoluminescent dosimeters (TLDs) were compared directly with EGS4 simulations of absorbed dose in homogeneous, heterogeneous and anthropomorphic phantoms. Realistic voxel-based models characterizing the geometry of the phantoms were used as input to the EGS4 code. The voxel geometry of the anthropomorphic Rando phantom was derived from a CT scan of Rando. The 100 kVp diagnostic energy x-ray spectra of the apparatus used to irradiate the phantoms were measured, and provided as input to the EGS4 code. The TLDs were placed at evenly spaced points symmetrically about the central beam axis, which was perpendicular to the cathode-anode x-ray axis at a number of depths. The TLD measurements in the homogeneous and heterogenous phantoms were on average within 7% of the values calculated by EGS4. Estimates of effective dose with errors less than 10% required fewer numbers of photon histories (1 x 10(7)) than required for the calculation of dose profiles (1 x 10(9)). The EGS4 code was able to satisfactorily predict and thereby provide an instrument for reducing patient and staff effective dose imparted during radiological investigations.
Diagnostic x-ray dosimetry using Monte Carlo simulation
NASA Astrophysics Data System (ADS)
Ioppolo, J. L.; Price, R. I.; Tuchyna, T.; Buckley, C. E.
2002-05-01
An Electron Gamma Shower version 4 (EGS4) based user code was developed to simulate the absorbed dose in humans during routine diagnostic radiological procedures. Measurements of absorbed dose using thermoluminescent dosimeters (TLDs) were compared directly with EGS4 simulations of absorbed dose in homogeneous, heterogeneous and anthropomorphic phantoms. Realistic voxel-based models characterizing the geometry of the phantoms were used as input to the EGS4 code. The voxel geometry of the anthropomorphic Rando phantom was derived from a CT scan of Rando. The 100 kVp diagnostic energy x-ray spectra of the apparatus used to irradiate the phantoms were measured, and provided as input to the EGS4 code. The TLDs were placed at evenly spaced points symmetrically about the central beam axis, which was perpendicular to the cathode-anode x-ray axis at a number of depths. The TLD measurements in the homogeneous and heterogenous phantoms were on average within 7% of the values calculated by EGS4. Estimates of effective dose with errors less than 10% required fewer numbers of photon histories (1 × 107) than required for the calculation of dose profiles (1 × 109). The EGS4 code was able to satisfactorily predict and thereby provide an instrument for reducing patient and staff effective dose imparted during radiological investigations.
Internal thyroid doses to Fukushima residents—estimation and issues remaining
Kim, Eunjoo; Kurihara, Osamu; Kunishima, Naoaki; Momose, Takumaro; Ishikawa, Tetsuo; Akashi, Makoto
2016-01-01
Enormous quantities of radionuclides were released into the environment following the disastrous accident at the Fukushima Daiichi Nuclear Power Plant (FDNPP) in March 2011. It is of great importance to determine the exposure doses received by the populations living in the radiologically affected areas; however, there has been significant difficulty in estimating the internal thyroid dose received through the intake of short-lived radionuclides (mainly, 131I), because of the lack of early measurements on people. An estimation by the National Institute of Radiological Sciences for 1 April 2012 to 31 March 2013 was thus performed using a combination of the following three sources: thyroid measurement data (131I) for 1080 children examined in the screening campaign, whole-body counter measurement data (134Cs, 137Cs) for 3000 adults, and atmospheric transport dispersion model simulations. In this study, the residents of Futaba town, Iitate village and Iwaki city were shown to have the highest thyroid equivalent dose, and their doses were estimated to be mostly below 30 mSv. However, this result involved a lot of uncertainties and provided only representative values for the residents. The present paper outlines a more recent dose estimation and preliminary analyses of personal behavior data used in the new method. PMID:27538842
Simplification of an MCNP model designed for dose rate estimation
NASA Astrophysics Data System (ADS)
Laptev, Alexander; Perry, Robert
2017-09-01
A study was made to investigate the methods of building a simplified MCNP model for radiological dose estimation. The research was done using an example of a complicated glovebox with extra shielding. The paper presents several different calculations for neutron and photon dose evaluations where glovebox elements were consecutively excluded from the MCNP model. The analysis indicated that to obtain a fast and reasonable estimation of dose, the model should be realistic in details that are close to the tally. Other details may be omitted.
Reduction of radiation dose in radiologic examination of patients with scoliosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hellstroem, G.; Irstam, L.; Nachemson, A.
In an attempt to reduce the radiation dose during the examination of scoliotic patients, several screen-film combinations have been compared with a conventional system used at present. Kodak's Lanex Regular screen with Kodak Ortho H film enables the dose to be reduced eight times without significant deterioration of the image quality. The dose to the mammary glands can be reduced further by a factor of five if posterior--anterior instead of anterior--posterior projection is used.
A reusable OSL-film for 2D radiotherapy dosimetry
NASA Astrophysics Data System (ADS)
Wouter, Crijns; Dirk, Vandenbroucke; Paul, Leblans; Tom, Depuydt
2017-11-01
Optical stimulated luminescence (OSL) combines reusability, sub-mm resolution, and a linear dose response in a single radiation detection technology. Such a combination is currently lacking in radiotherapy dosimetry. But OSL-films have a strong energy dependent response to keV photons due to a relative high effective atomic number (Z eff). The current work studied the applicability of a 2D OSL-film with a reduced Z eff as (IMRT/VMAT) dosimeter. Based on their commercial OSL-film experience, Agfa Healthcare N.V. produced a new experimental OSL-film for RT dosimetry. This film had a lower effective atomic number compared to the films used in radiology. Typical 2D dosimeter requirements such as uniformity, dose response, signal stability with time, and angular dependence were evaluated. Additionally, the impact of a possible residual energy dependence was assessed for the infield as well as the out-of-field region of both static beams and standard intensity modulated patterns (chair and pyramid). The OSL-film’s reusable nature allowed for a film specific absolute and linear calibration including a flood-field uniformity correction. The OSL-film was scanned with a CR-15X engine based reader using a strict timing (i.e. 4 min after ‘beam on’ or as soon as possible) to account for spontaneous recombination. The OSL-film had good basic response properties: non-uniformities ⩽2.6%, a linear dose response (0-32 Gy), a linear signal decay (0.5% min-1) over the 20 min measured, and limited angular dependence ⩽2.6%. Due to variations of the energy spectrum, larger dose differences were noted outside the central region of the homogenous phantom and outside both static and IMRT fields. However, the OSL-film’s measured dose differences of the IMRT patterns were lower than those of Gafchromic EBT measurements ([-1.6%, 2.1%] versus [-2.9%, 3.6%]). The current OSL-film could be used as a reusable high resolution dosimeter with read-out immediately after irradiation. Inside the (IMRT) treatment fields residual energy dependent effects were not observed. Novelty and significance: Implementing a reusable optical stimulated luminescence (OSL) film for radiotherapy dosimetry would enable user-friendly, sub(mm) resolution 2D dosimetry with instantaneous read-out. Radiology OSL-films have a strong energy dependent response which hampers accurate dosimetry. The current work reports measurements with a first 2D OSL-film tailored to the radiotherapy needs: including an improved water equivalent composition. The dosimeter adds the ability for sub-mm resolution repeated measurements to the portfolio of radiotherapy dosimetry.
A reusable OSL-film for 2D radiotherapy dosimetry.
Wouter, Crijns; Dirk, Vandenbroucke; Paul, Leblans; Tom, Depuydt
2017-10-19
Optical stimulated luminescence (OSL) combines reusability, sub-mm resolution, and a linear dose response in a single radiation detection technology. Such a combination is currently lacking in radiotherapy dosimetry. But OSL-films have a strong energy dependent response to keV photons due to a relative high effective atomic number (Z eff ). The current work studied the applicability of a 2D OSL-film with a reduced Z eff as (IMRT/VMAT) dosimeter. Based on their commercial OSL-film experience, Agfa Healthcare N.V. produced a new experimental OSL-film for RT dosimetry. This film had a lower effective atomic number compared to the films used in radiology. Typical 2D dosimeter requirements such as uniformity, dose response, signal stability with time, and angular dependence were evaluated. Additionally, the impact of a possible residual energy dependence was assessed for the infield as well as the out-of-field region of both static beams and standard intensity modulated patterns (chair and pyramid). The OSL-film's reusable nature allowed for a film specific absolute and linear calibration including a flood-field uniformity correction. The OSL-film was scanned with a CR-15X engine based reader using a strict timing (i.e. 4 min after 'beam on' or as soon as possible) to account for spontaneous recombination. The OSL-film had good basic response properties: non-uniformities ⩽2.6%, a linear dose response (0-32 Gy), a linear signal decay (0.5% min -1 ) over the 20 min measured, and limited angular dependence ⩽2.6%. Due to variations of the energy spectrum, larger dose differences were noted outside the central region of the homogenous phantom and outside both static and IMRT fields. However, the OSL-film's measured dose differences of the IMRT patterns were lower than those of Gafchromic EBT measurements ([-1.6%, 2.1%] versus [-2.9%, 3.6%]). The current OSL-film could be used as a reusable high resolution dosimeter with read-out immediately after irradiation. Inside the (IMRT) treatment fields residual energy dependent effects were not observed. Novelty and significance: Implementing a reusable optical stimulated luminescence (OSL) film for radiotherapy dosimetry would enable user-friendly, sub(mm) resolution 2D dosimetry with instantaneous read-out. Radiology OSL-films have a strong energy dependent response which hampers accurate dosimetry. The current work reports measurements with a first 2D OSL-film tailored to the radiotherapy needs: including an improved water equivalent composition. The dosimeter adds the ability for sub-mm resolution repeated measurements to the portfolio of radiotherapy dosimetry.
Sultanem, Khalil; Patrocinio, Horacio; Lambert, Christine; Corns, Robert; Leblanc, Richard; Parker, William; Shenouda, George; Souhami, Luis
2004-01-01
Despite major advances in treatment modalities, the prognosis of patients with glioblastoma multiforme (GBM) remains poor. Exploring hypofractionated regimens to replace the standard 6-week radiotherapy schedule is an attractive strategy as an attempt to prevent accelerated tumor cell repopulation. There is equally interest in dose escalation to the gross tumor volume where the majority of failures occur. We report our preliminary results using hypofractionated intensity-modulated accelerated radiotherapy regimen in the treatment of patients with GBM. Between July 1998 and December 2001, 25 patients with histologically proven diagnosis of GBM, Karnofsky performance status > or =60, and a postoperative tumor volume < or =110 cm3 were treated with a hypofractionated accelerated course of radiotherapy. The gross tumor volume (GTV) was defined as the contrast-enhancing lesion on the postoperative MRI T1-weighted images with the latter fused with computed tomography images for treatment planning. The planning target volume was defined as GTV + 1.5-cm margin. Using forward-planning intensity modulation (step-and-shoot technique), 60 Gy in 20 daily fractions of 3 Gy each were given to the GTV, whereas the planning target volume received a minimum of 40 Gy in 20 fractions of 2 Gy each at its periphery. Treatments were delivered over a 4-week period using 5 daily fractions per week. Dose was prescribed at the isocenter (ICRU point). Three beam angles were used in all of the cases. Treatments were well tolerated. Acute toxicity was limited to increased brain edema during radiotherapy in 2 patients who were on tapering doses of corticosteroids. This was corrected by increasing the steroid dose. At a median follow-up of 8.8 months, no late toxicity was observed. One patient experienced visual loss at 9 months after completion of treatment. MRI suggested nonspecific changes to the optic chiasm. On review of the treatment plan, the total dose to the optic chiasm was confirmed to be equal to or less than 40 Gy in 20 fractions. When Radiation Therapy Oncology Group recursive partitioning analysis was used, 10 patients were class III-IV, and 15 patients were class V-VI. To date, 21 patients have had clinical and/or radiologic evidence of disease progression, and 16 patients have died. The median survival was 9.5 months (range: 2.8-22.9 months), the 1-year survival rate was 40%, and the median progression-free survival was 5.2 months (range: 1.9-12.8 months). This hypofractionated accelerated irradiation schedule using forward planning (step-and-shoot) hypofractionated, intensity-modulated accelerated radiotherapy is feasible and seems to be a safe treatment for patients with GBM. A 2-week reduction in the treatment time may be of valuable benefit for this group of patients. However, despite this accelerated regimen, no survival advantage has been observed.
Simon, Steven L.
2014-01-01
While radiation absorbed dose (Gy) to the skin or other organs is sometimes estimated for patients from diagnostic radiologic examinations or therapeutic procedures, rarely is occupationally-received radiation absorbed dose to individual organs/tissues estimated for medical personnel, e.g., radiologic technologists or radiologists. Generally, for medical personnel, equivalent or effective radiation doses are estimated for compliance purposes. In the very few cases when organ doses to medical personnel are reconstructed, the data is usually for the purpose of epidemiologic studies, e.g., a study of historical doses and risks to a cohort of about 110,000 radiologic technologists presently underway at the U.S. National Cancer Institute. While ICRP and ICRU have published organ-specific external dose conversion coefficients (DCCs), i.e., absorbed dose to organs and tissues per unit air kerma and dose equivalent per unit air kerma, those factors have been primarily published for mono-energetic photons at selected energies. This presents two related problems for historical dose reconstruction, both of which are addressed here. It is necessary to derive conversion factors values for (i) continuous distributions of energy typical of diagnostic medical x rays (bremsstrahlung radiation), and (ii) for energies of particular radioisotopes used in medical procedures, neither of which are presented in published tables. For derivation of DCCs for bremsstrahlung radiation, combinations of x-ray tube potentials and filtrations were derived for different time periods based on a review of relevant literature. Three peak tube potentials (70 kV, 80 kV, and 90 kV) with four different amounts of beam filtration were determined to be applicable for historic dose reconstruction. The probability of these machine settings were assigned to each of the four time periods (earlier than 1949, 1949-1954, 1955-1968, and after 1968). Continuous functions were fit to each set of discrete values of the ICRP/ICRU mono-energetic DCCs and the functions integrated over the air-kerma weighted photon fluence of the 12 defined x-ray spectra. The air kerma-weighted DCCs in this work were developed specifically for an irradiation geometry of anterior to posterior (AP) and for the following tissues: thyroid, breast, ovary, lens of eye, lung, colon, testes, heart, skin (anterior side only), red bone marrow (RBM), heart, and brain. In addition, a series of functional relationships to predict DT per Ka values for RBM dependent on body mass index [BMI (kg m−2) ≡ weight per height2] and average photon energy were derived from a published analysis. Factors to account for attenuation of radiation by protective lead aprons were also developed. Because lead protective aprons often worn by radiology personnel not only reduce the intensity of x-ray exposure but also appreciably harden the transmitted fluence of bremsstrahlung x rays, DCCs were separately calculated for organs possibly protected by lead aprons by considering three cases: no apron, 0.25 mm Pb apron, and 0.5 mm Pb apron. For estimation of organ doses from conducting procedures with radioisotopes, continuous functions of the reported mono-energetic values were developed and DCCs were derived by estimation of the function at relevant energies. By considering the temporal changes in primary exposure-related parameters, e.g., energy distribution, the derived DCCs and transmission factors presented here allow for more realistic historical dose reconstructions for medical personnel when monitoring badge readings are the primary data on which estimation of an individual's organ doses are based. PMID:21617389
Simon, Steven L
2011-07-01
While radiation absorbed dose (Gy) to the skin or other organs is sometimes estimated for patients from diagnostic radiologic examinations or therapeutic procedures, rarely is occupationally-received radiation absorbed dose to individual organs/tissues estimated for medical personnel; e.g., radiologic technologists or radiologists. Generally, for medical personnel, equivalent or effective radiation doses are estimated for compliance purposes. In the very few cases when organ doses to medical personnel are reconstructed, the data is usually for the purpose of epidemiologic studies; e.g., a study of historical doses and risks to a cohort of about 110,000 radiologic technologists presently underway at the U.S. National Cancer Institute. While ICRP and ICRU have published organ-specific external dose conversion coefficients (DCCs) (i.e., absorbed dose to organs and tissues per unit air kerma and dose equivalent per unit air kerma), those factors have been published primarily for mono-energetic photons at selected energies. This presents two related problems for historical dose reconstruction, both of which are addressed here. It is necessary to derive conversion factor values for (1) continuous distributions of energy typical of diagnostic medical x-rays (bremsstrahlung radiation), and (2) energies of particular radioisotopes used in medical procedures, neither of which are presented in published tables. For derivation of DCCs for bremsstrahlung radiation, combinations of x-ray tube potentials and filtrations were derived for different time periods based on a review of relevant literature. Three peak tube potentials (70 kV, 80 kV, and 90 kV) with four different amounts of beam filtration were determined to be applicable for historic dose reconstruction. The probabilities of these machine settings were assigned to each of the four time periods (earlier than 1949, 1949-1954, 1955-1968, and after 1968). Continuous functions were fit to each set of discrete values of the ICRP/ICRU mono-energetic DCCs and the functions integrated over the air-kerma weighted photon fluence of the 12 defined x-ray spectra. The air kerma-weighted DCCs in this work were developed specifically for an irradiation geometry of anterior to posterior (AP) and for the following tissues: thyroid, breast, ovary, lens of eye, lung, colon, testes, heart, skin (anterior side only), red bone marrow (RBM), and brain. In addition, a series of functional relationships to predict DT Ka-1 values for RBM dependent on body mass index [BMI (kg m-2) ≡ weight per height] and average photon energy were derived from a published analysis. Factors to account for attenuation of radiation by protective lead aprons were also developed. Because lead protective aprons often worn by radiology personnel not only reduce the intensity of x-ray exposure but also appreciably harden the transmitted fluence of bremsstrahlung x-rays, DCCs were separately calculated for organs possibly protected by lead aprons by considering three cases: no apron, 0.25 mm Pb apron, and 0.5 mm Pb apron. For estimation of organ doses from conducting procedures with radioisotopes, continuous functions of the reported mono-energetic values were developed, and DCCs were derived by estimation of the function at relevant energies. By considering the temporal changes in primary exposure-related parameters (e.g., energy distribution), the derived DCCs and transmission factors presented here allow for more realistic historical dose reconstructions for medical personnel when monitoring badge readings are the primary data on which estimation of an individual's organ doses are based.
38 CFR 3.311 - Claims based on exposure to ionizing radiation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... body in the field of health physics, nuclear medicine or radiology and if based on analysis of the... will be forwarded to the Under Secretary for Health, who will be responsible for preparation of a dose... the National Institutes of Health, who shall prepare a separate radiation dose estimate for...
Gene Expression in Parp1 Deficient Mice Exposed to a Median Lethal Dose of Gamma Rays.
Kumar, M A Suresh; Laiakis, Evagelia C; Ghandhi, Shanaz A; Morton, Shad R; Fornace, Albert J; Amundson, Sally A
2018-05-10
There is a current interest in the development of biodosimetric methods for rapidly assessing radiation exposure in the wake of a large-scale radiological event. This work was initially focused on determining the exposure dose to an individual using biological indicators. Gene expression signatures show promise for biodosimetric application, but little is known about how these signatures might translate for the assessment of radiological injury in radiosensitive individuals, who comprise a significant proportion of the general population, and who would likely require treatment after exposure to lower doses. Using Parp1 -/- mice as a model radiation-sensitive genotype, we have investigated the effect of this DNA repair deficiency on the gene expression response to radiation. Although Parp1 is known to play general roles in regulating transcription, the pattern of gene expression changes observed in Parp1 -/- mice 24 h postirradiation to a LD 50/30 was remarkably similar to that in wild-type mice after exposure to LD 50/30 . Similar levels of activation of both the p53 and NFκB radiation response pathways were indicated in both strains. In contrast, exposure of wild-type mice to a sublethal dose that was equal to the Parp1 -/- LD 50/30 , which resulted in a lower magnitude gene expression response. Thus, Parp1 -/- mice displayed a heightened gene expression response to radiation, which was more similar to the wild-type response to an equitoxic dose than to an equal absorbed dose. Gene expression classifiers trained on the wild-type data correctly identified all wild-type samples as unexposed, exposed to a sublethal dose or exposed to an LD 50/30 . All unexposed samples from Parp1 -/- mice were also correctly classified with the same gene set, and 80% of irradiated Parp1 -/- samples were identified as exposed to an LD 50/30 . The results of this study suggest that, at least for some pathways that may influence radiosensitivity in humans, specific gene expression signatures have the potential to accurately detect the extent of radiological injury, rather than serving only as a surrogate of physical radiation dose.
Evaluation of discrepancies between thermoluminescent dosimeter and direct-reading dosimeter results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shaw, K.R.
1993-07-01
Currently at Oak Ridge National Laboratory (ORNL), the responses of thermoluminescent dosimeters (TLDs) and direct-reading dosimeters (DRDs) are not officially compared or the discrepancies investigated. However, both may soon be required due to the new US Department of Energy (DOE) Radiological Control Manual. In the past, unofficial comparisons of the two dosimeters have led to discrepancies of up to 200%. This work was conducted to determine the reasons behind such discrepancies. For tests conducted with the TLDs, the reported dose was most often lower than the delivered dose, while DRDs most often responded higher than the delivered dose. Trends weremore » identified in personnel DRD readings, and ft was concluded that more training and more control of the DRDs could improve their response. TLD responses have already begun to be improved; a new background subtraction method was implemented in April 1993, and a new dose algorithm is being considered. It was concluded that the DOE Radiological Control Manual requirements are reasonable for identifying discrepancies between dosimeter types, and more stringent administrative limits might even be considered.« less
Lee, Young Han; Song, Ho-Taek; Suh, Jin-Suck
2012-12-01
The objectives are (1) to introduce a new concept of making a quantitative computed tomography (QCT) reporting system by using optical character recognition (OCR) and macro program and (2) to illustrate the practical usages of the QCT reporting system in radiology reading environment. This reporting system was created as a development tool by using an open-source OCR software and an open-source macro program. The main module was designed for OCR to report QCT images in radiology reading process. The principal processes are as follows: (1) to save a QCT report as a graphic file, (2) to recognize the characters from an image as a text, (3) to extract the T scores from the text, (4) to perform error correction, (5) to reformat the values into QCT radiology reporting template, and (6) to paste the reports into the electronic medical record (EMR) or picture archiving and communicating system (PACS). The accuracy test of OCR was performed on randomly selected QCTs. QCT as a radiology reporting tool successfully acted as OCR of QCT. The diagnosis of normal, osteopenia, or osteoporosis is also determined. Error correction of OCR is done with AutoHotkey-coded module. The results of T scores of femoral neck and lumbar vertebrae had an accuracy of 100 and 95.4 %, respectively. A convenient QCT reporting system could be established by utilizing open-source OCR software and open-source macro program. This method can be easily adapted for other QCT applications and PACS/EMR.
Methods for CT automatic exposure control protocol translation between scanner platforms.
McKenney, Sarah E; Seibert, J Anthony; Lamba, Ramit; Boone, John M
2014-03-01
An imaging facility with a diverse fleet of CT scanners faces considerable challenges when propagating CT protocols with consistent image quality and patient dose across scanner makes and models. Although some protocol parameters can comfortably remain constant among scanners (eg, tube voltage, gantry rotation time), the automatic exposure control (AEC) parameter, which selects the overall mA level during tube current modulation, is difficult to match among scanners, especially from different CT manufacturers. Objective methods for converting tube current modulation protocols among CT scanners were developed. Three CT scanners were investigated, a GE LightSpeed 16 scanner, a GE VCT scanner, and a Siemens Definition AS+ scanner. Translation of the AEC parameters such as noise index and quality reference mAs across CT scanners was specifically investigated. A variable-diameter poly(methyl methacrylate) phantom was imaged on the 3 scanners using a range of AEC parameters for each scanner. The phantom consisted of 5 cylindrical sections with diameters of 13, 16, 20, 25, and 32 cm. The protocol translation scheme was based on matching either the volumetric CT dose index or image noise (in Hounsfield units) between two different CT scanners. A series of analytic fit functions, corresponding to different patient sizes (phantom diameters), were developed from the measured CT data. These functions relate the AEC metric of the reference scanner, the GE LightSpeed 16 in this case, to the AEC metric of a secondary scanner. When translating protocols between different models of CT scanners (from the GE LightSpeed 16 reference scanner to the GE VCT system), the translation functions were linear. However, a power-law function was necessary to convert the AEC functions of the GE LightSpeed 16 reference scanner to the Siemens Definition AS+ secondary scanner, because of differences in the AEC functionality designed by these two companies. Protocol translation on the basis of quantitative metrics (volumetric CT dose index or measured image noise) is feasible. Protocol translation has a dependency on patient size, especially between the GE and Siemens systems. Translation schemes that preserve dose levels may not produce identical image quality. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Gunko, N V
2015-12-01
Evaluation of efficacy of the managed population transmigration from zone of obligate (compulsory) resettlement as a measure of civil protection after the Chernobyl NPP accident from the perspective of radiation biology. Legislative and statutory tutorial documents that regulate the managed population shift from radiologically contaminated territories of Ukraine and data from the Ukrainian State Service of Statistics on time limits and scopes of population transmigration from contaminated settlements were the informational back ground of the study. Data on retrospective and expected/anticipated radiation doses in population of settlements exposed to radiological contamination in Ukraine after the Chernobyl disaster summarized for the 1986-1997 peri od and up to 2055 were the information source for calculation of averted doses due to population shift. Battery of basic research empirical evidence review methods was applied under the calculation, systemic, and biomedical approach. Population shift from zone of obligate (compulsore) resettlement (hereafter referred to as Zone 2) to stop the radiation exposure as a tool of civil protection from emergency ionizing radiation after the Chernobyl NPP accident was scientifically substantiated and expedient from the perspective of radiation biology. Estimability of a managed population shift from "dose effect" perspective and "benefit/harm" principle is worse because of data absence on individual radiation doses to migrants in the country. Public shift in 1990 and 1991 was most effective from the viewpoint of level of averted lifetime dose. Due to transmigration the averted lifetime dose to the most vulnerable group of the Chernobyl disaster survivors i.e. children aged 0 years varied from 11.2 to 28.8 mSv (calculated for the Perejizdiv village council of Zhytomyr province). Since 2000 there was almost no public shift being not accomplished in the scheduled scope. Delay and incompleteness of transmigration have diminished the efficacy of this measure in the framework of radiological protection of population. N. V. Gunko.
Minter, Kelsey M; Jannik, G Timothy; Stagich, Brooke H; Dixon, Kenneth L; Newton, Joseph R
2018-04-01
The U.S. Environmental Protection Agency (EPA) requires the use of the model CAP88 to estimate the total effective dose (TED) to an offsite maximally exposed individual (MEI) for demonstrating compliance with 40 CFR 61, Subpart H: The National Emission Standards for Hazardous Air Pollutants (NESHAP) regulations. For NESHAP compliance at the Savannah River Site (SRS), the EPA, the U.S. Department of Energy (DOE), South Carolina's Department of Health and Environmental Control, and SRS approved a dose assessment method in 1991 that models all radiological emissions as if originating from a generalized center of site (COS) location at two allowable stack heights (0 m and 61 m). However, due to changes in SRS missions, radiological emissions are no longer evenly distributed about the COS. An area-specific simulation of the 2015 SRS radiological airborne emissions was conducted to compare to the current COS method. The results produced a slightly higher dose estimate (2.97 × 10 mSv vs. 2.22 × 10 mSv), marginally changed the overall MEI location, and noted that H-Area tritium emissions dominated the dose. Thus, an H-Area dose model was executed as a potential simplification of the area-specific simulation by adopting the COS methodology and modeling all site emissions from a single location in H-Area using six stack heights that reference stacks specific to the tritium production facilities within H-Area. This "H-Area Tritium Stacks" method produced a small increase in TED estimates (3.03 × 10 mSv vs. 2.97 × 10 mSv) when compared to the area-specific simulation. This suggests that the current COS method is still appropriate for demonstrating compliance with NESHAP regulations but that changing to the H-Area Tritium Stacks assessment method may now be a more appropriate representation of operations at SRS.
Alexander, Andrew George; Deas, Deborah; Lyons, Paul Eric
2018-05-18
Imaging and its optimal use are imperative to the practice of medicine, yet many students don't receive a formal education in radiology. Concurrently, students look for ways to take time away from medical school for residency interviewing. Web-based instruction provides an opportunity to combine these imperatives using online modalities. A largely Web-based course in radiology during the 4th year of medical school was evaluated both for its acceptance to students who needed to be away from campus for interviews, and its effectiveness on a nationally administered standardized test. All students were placed into a structured program utilizing online videos, online modules, online textbook assignments, and live interactive online lectures. Over half of the course could be completed away from campus. The Alliance of Medical Student Educators in Radiology test exam bank was used as a final exam to evaluate medical knowledge. Positive student feedback included the freedom to travel for interviews, hands-on ultrasound training, interactive teaching sessions, and quality Web-based learning modules. Negative feedback included taking quizzes in-person, a perceived outdated online textbook, and physically shadowing hospital technicians. Most students elected to take the course during the interview months of October through January. The Alliance of Medical Student Educators in Radiology final exam results (70.5%) were not significantly different than the national cohort (70%) who took the course in-person. Test scores from students taking the course during interview travel months were not significantly different from students who took the course before (P=.30) or after (P=.34) the interview season. Students desire to learn radiology and often choose to do so when they need to be away from campus during the fall of their 4th year of study to accomplish their residency interviews. Web-based education in radiology allows students' interview traveling and radiology course objectives to be successfully met without adversely affecting the outcomes on a nationally normed examination in radiology. A curriculum that includes online content and live Web-based teleconference access to faculty can accomplish both imperatives. ©Andrew George Alexander, Deborah Deas, Paul Eric Lyons. Originally published in JMIR Medical Education (http://mededu.jmir.org), 18.05.2018.
Systems and methods for detecting and processing
Johnson, Michael M [Livermore, CA; Yoshimura, Ann S [Tracy, CA
2006-03-28
Embodiments of the present invention provides systems and method for detecting. Sensing modules are provided in communication with one or more detectors. In some embodiments, detectors are provided that are sensitive to chemical, biological, or radiological agents. Embodiments of sensing modules include processing capabilities to analyze, perform computations on, and/or run models to predict or interpret data received from one or more detectors. Embodiments of sensing modules form various network configurations with one another and/or with one or more data aggregation devices. Some embodiments of sensing modules include power management functionalities.
NASA Astrophysics Data System (ADS)
Fu, Wanyi; Sturgeon, Gregory M.; Agasthya, Greeshma; Segars, W. Paul; Kapadia, Anuj J.; Samei, Ehsan
2017-03-01
This study aimed to estimate the organ dose reduction potential for organ-dose-based tube current modulated (ODM) thoracic CT with wide dose reduction arc. Twenty-one computational anthropomorphic phantoms (XCAT, age range: 27- 75 years, weight range: 52.0-105.8 kg) were used to create a virtual patient population with clinical anatomic variations. For each phantom, two breast tissue compositions were simulated: 50/50 and 20/80 (glandular-to-adipose ratio). A validated Monte Carlo program was used to estimate the organ dose for standard tube current modulation (TCM) (SmartmA, GE Healthcare) and ODM (GE Healthcare) for a commercial CT scanner (Revolution, GE Healthcare) with explicitly modeled tube current modulation profile, scanner geometry, bowtie filtration, and source spectrum. Organ dose was determined using a typical clinical thoracic CT protocol. Both organ dose and CTDIvol-to-organ dose conversion coefficients (h factors) were compared between TCM and ODM. ODM significantly reduced all radiosensitive organ doses (p<0.01). The breast dose was reduced by 30+/-2%. For h factors, organs in the anterior region (e.g. thyroid, stomach) exhibited substantial decreases, and the medial, distributed, and posterior region either saw an increase or no significant change. The organ-dose-based tube current modulation significantly reduced organ doses especially for radiosensitive superficial anterior organs such as the breasts.
Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT.
Ludlow, J B; Davies-Ludlow, L E; Brooks, S L; Howerton, W B
2006-07-01
Cone beam computed tomography (CBCT), which provides a lower dose, lower cost alternative to conventional CT, is being used with increasing frequency in the practice of oral and maxillofacial radiology. This study provides comparative measurements of effective dose for three commercially available, large (12'') field-of-view (FOV), CBCT units: CB Mercuray, NewTom 3G and i-CAT. Thermoluminescent dosemeters (TLDs) were placed at 24 sites throughout the layers of the head and neck of a tissue-equivalent human skull RANDO phantom. Depending on availability, the 12'' FOV and smaller FOV scanning modes were used with similar phantom positioning geometry for each CBCT unit. Radiation weighted doses to individual organs were summed using 1990 (E(1990)) and proposed 2005 (E(2005 draft)) ICRP tissue weighting factors to calculate two measures of whole-body effective dose. Dose as a multiple of a representative panoramic radiography dose was also calculated. For repeated runs dosimetry was generally reproducible within 2.5%. Calculated doses in microSv [corrected] (E(1990), E(2005 draft)) were NewTom3G (45, 59), i-CAT (135, 193) and CB Mercuray (477, 558). These are 4 to 42 times greater than comparable panoramic examination doses (6.3 microSv [corrected] 13.3 mSv). Reductions in dose were seen with reduction in field size and mA and kV technique factors. CBCT dose varies substantially depending on the device, FOV and selected technique factors. Effective dose detriment is several to many times higher than conventional panoramic imaging and an order of magnitude or more less than reported doses for conventional CT.
Reduced-dose C-arm computed tomography applications at a pediatric institution.
Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S; Cahill, Anne Marie
2017-12-01
Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance.
Kakkar, Chandan; Sripathi, Smiti; Parakh, Anushri; Shrivastav, Rajendra
2016-01-01
Introduction Urolithiasis is one of the major, recurring problem in young individuals and CT being the commonest diagnostic modality used. In order to reduce the radiation dose to the patient who are young and as stone formation is a recurring process; one of the simplest way would be, low dose CT along with tube current modulation. Aim Aim of this study was to compare the sensitivity and specificity of low dose (70mAs) with standard dose (250mAs) protocol in detecting urolithiasis and to define the tube current and mean effective patient dose by these protocols. Materials and Methods A prospective study was conducted in 200 patients over a period of 2 years with acute flank pain presentation. CT was performed in 100 cases with standard dose and another 100 with low dose protocol using tube current modulation. Sensitivity and specificity for calculus detection, percentage reduction of dose and tube current with low dose protocol was calculated. Results Urolithiasis was detected in 138 patients, 67 were examined by high dose and 71 were by low dose protocol. Sensitivity and Specificity of low dose protocol was 97.1% and 96.4% with similar results found in high BMI patients. Tube current modulation resulted in reduction of effective tube current by 12.17%. The mean effective patient dose for standard dose was 10.33 mSv whereas 2.92 mSv for low dose with 51.13–53.8% reduction in low dose protocol. Conclusion The study has reinforced that low-dose CT with tube current modulation is appropriate for diagnosis of urolithiasis with significant reduction in tube current and patient effective dose. PMID:27437322
Koteshwar, Prakashini; Kakkar, Chandan; Sripathi, Smiti; Parakh, Anushri; Shrivastav, Rajendra
2016-05-01
Urolithiasis is one of the major, recurring problem in young individuals and CT being the commonest diagnostic modality used. In order to reduce the radiation dose to the patient who are young and as stone formation is a recurring process; one of the simplest way would be, low dose CT along with tube current modulation. Aim of this study was to compare the sensitivity and specificity of low dose (70mAs) with standard dose (250mAs) protocol in detecting urolithiasis and to define the tube current and mean effective patient dose by these protocols. A prospective study was conducted in 200 patients over a period of 2 years with acute flank pain presentation. CT was performed in 100 cases with standard dose and another 100 with low dose protocol using tube current modulation. Sensitivity and specificity for calculus detection, percentage reduction of dose and tube current with low dose protocol was calculated. Urolithiasis was detected in 138 patients, 67 were examined by high dose and 71 were by low dose protocol. Sensitivity and Specificity of low dose protocol was 97.1% and 96.4% with similar results found in high BMI patients. Tube current modulation resulted in reduction of effective tube current by 12.17%. The mean effective patient dose for standard dose was 10.33 mSv whereas 2.92 mSv for low dose with 51.13-53.8% reduction in low dose protocol. The study has reinforced that low-dose CT with tube current modulation is appropriate for diagnosis of urolithiasis with significant reduction in tube current and patient effective dose.
Dosimetric measurements and comparison studies in digital imaging system
NASA Astrophysics Data System (ADS)
Jung, Ji-Young; Kim, Hee-Joung; Lee, Chang-Lae; Cho, Hyo-Min; Nam, Sora
2008-03-01
Number of radiologic exams using digital imaging systems has rapidly increased with advanced imaging technologies. However, it has not been paid attention to the radiation dose in clinical situations. It was the motivation to study radiation dosimetry in the DR system. The objective of this study was to measure beam quality and patient's dose using DR system and to compare them to both IEC standard and IAEA guidelines. The measured average dose for chest and abdomen was 1.376 mGy and 9.501 mGy, respectively, compared to 0.4 mGy and 10.0 mGy in IAEA guidelines. The results also indicated that the DR system has a lower radiation beam quality than that of the IEC standard. The results showed that the patients may be exposed higher radiation for chest exams and lower radiation for abdomen exams using DR system. IAEA Guidelines were prepared based on western people which may be different weight and height for patients compared them to Korean. In conclusion, a new guideline for acceptable DR dosimetry for Korean patients may need to be developed with further studies for large populations. We believe that this research greatly help to introduce the importance of the dosimetry in diagnostic radiology in Korea. And, a development of database for dosimetry in diagnostic radiology will become an opportunity of making aware of radiation safety of medical examination to patient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robison, W.L.
1990-09-01
Bikini Island and Bikini Lagoon were contaminated by fallout from nuclear weapons tests conducted at the atoll by the United States from 1946 to 1958. The second test, Baker, of the Crossroads series was an underwater detonation in 1946 that sank several ships in the lagoon, including the USS Saratoga and the Japanese battleship Nagato. The ships received high-intensity gamma-ray and neutron bombardment from the Baker test, which induced radioactivity in the metal structures. Some of the tests conducted after the Baker shot (there were 21 tests in all) injected contaminated carbonate particles into the air, some of which weremore » deposited across the lagoon surface. Most of this contaminated soil then settled onto the ships` decks and other structures and on the lagoon bottom. These sunken ships provide an interesting location for divers. Recreational diving and swimming in and around the ships raises the question of the potential radiological dose from the radionuclides present in or on the ships and in the lagoon sediments. The purpose of this paper, therefore, is to present an analysis of the potential radiological dose to persons who would dive near the sunken ships and live on Bikini Island for a short period of time.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robison, W.L.
1990-09-01
Bikini Island and Bikini Lagoon were contaminated by fallout from nuclear weapons tests conducted at the atoll by the United States from 1946 to 1958. The second test, Baker, of the Crossroads series was an underwater detonation in 1946 that sank several ships in the lagoon, including the USS Saratoga and the Japanese battleship Nagato. The ships received high-intensity gamma-ray and neutron bombardment from the Baker test, which induced radioactivity in the metal structures. Some of the tests conducted after the Baker shot (there were 21 tests in all) injected contaminated carbonate particles into the air, some of which weremore » deposited across the lagoon surface. Most of this contaminated soil then settled onto the ships' decks and other structures and on the lagoon bottom. These sunken ships provide an interesting location for divers. Recreational diving and swimming in and around the ships raises the question of the potential radiological dose from the radionuclides present in or on the ships and in the lagoon sediments. The purpose of this paper, therefore, is to present an analysis of the potential radiological dose to persons who would dive near the sunken ships and live on Bikini Island for a short period of time.« less
ERIC Educational Resources Information Center
Chardenet, Kathleen A.
2016-01-01
Purpose: A real-time dose management system was used to determine if radiation exposure levels would decrease when providers were privy to their real-time radiation exposure levels. Six aggregate categories of providers were first blinded (phase 1) and subsequently made aware of their radiation exposure levels during electrophysiology procedures…
Environmental radioactivity levels, Browns Ferry Nuclear Plant. Annual report, 1983
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1984-04-01
This report describes the environmental radiological monitoring of the Browns Ferry Nuclear Plant (BFN), located in Limestone County, Alabama, conducted in 1983. Dose estimates were calculated from concentrations of radioactivity found in samples of air, milk, meat, vegetation, drinking water, and fish. Estimated doses were essentially identical to those determined at control locations. 12 figures, 29 tables.
Radiation protection and dosimetry issues in the medical applications of ionizing radiation
NASA Astrophysics Data System (ADS)
Vaz, Pedro
2014-11-01
The technological advances that occurred during the last few decades paved the way to the dissemination of CT-based procedures in radiology, to an increasing number of procedures in interventional radiology and cardiology as well as to new techniques and hybrid modalities in nuclear medicine and in radiotherapy. These technological advances encompass the exposure of patients and medical staff to unprecedentedly high dose values that are a cause for concern due to the potential detrimental effects of ionizing radiation to the human health. As a consequence, new issues and challenges in radiological protection and dosimetry in the medical applications of ionizing radiation have emerged. The scientific knowledge of the radiosensitivity of individuals as a function of age, gender and other factors has also contributed to raising the awareness of scientists, medical staff, regulators, decision makers and other stakeholders (including the patients and the public) for the need to correctly and accurately assess the radiation induced long-term health effects after medical exposure. Pediatric exposures and their late effects became a cause of great concern. The scientific communities of experts involved in the study of the biological effects of ionizing radiation have made a strong case about the need to undertake low dose radiation research and the International System of Radiological Protection is being challenged to address and incorporate issues such as the individual sensitivities, the shape of dose-response relationship and tissue sensitivity for cancer and non-cancer effects. Some of the answers to the radiation protection and dosimetry issues and challenges in the medical applications of ionizing radiation lie in computational studies using Monte Carlo or hybrid methods to model and simulate particle transport in the organs and tissues of the human body. The development of sophisticated Monte Carlo computer programs and voxel phantoms paves the way to an accurate dosimetric assessment of the medical applications of ionizing radiation. In this paper, the aforementioned topics will be reviewed. The current status and the future trends in the implementation of the justification and optimization principles, pillars of the International System of Radiological Protection, in the medical applications of ionizing radiation will be discussed. Prospective views will be provided on the future of the system of radiological protection and on dosimetry issues in the medical applications of ionizing radiation.
Morel, Baptiste; Moueddeb, Sonia; Blondiaux, Eleonore; Richard, Stephen; Bachy, Manon; Vialle, Raphael; Ducou Le Pointe, Hubert
2018-05-01
The aim of this study was to compare the radiation dose, image quality and 3D spine parameter measurements of EOS low-dose and micro-dose protocols for in-brace adolescent idiopathic scoliosis (AIS) patients. We prospectively included 25 consecutive patients (20 females, 5 males) followed for AIS and undergoing brace treatment. The mean age was 12 years (SD 2 years, range 8-15 years). For each patient, in-brace biplanar EOS radiographs were acquired in a standing position using both the conventional low-dose and micro-dose protocols. Dose area product (DAP) was systematically recorded. Diagnostic image quality was qualitatively assessed by two radiologists for visibility of anatomical structures. The reliability of 3D spine modeling between two operators was quantitatively evaluated for the most clinically relevant 3D radiological parameters using intraclass correlation coefficient (ICC). The mean DAP for the posteroanterior and lateral acquisitions was 300 ± 134 and 433 ± 181 mGy cm 2 for the low-dose radiographs, and 41 ± 19 and 81 ± 39 mGy cm 2 for micro-dose radiographs. Image quality was lower with the micro-dose protocol. The agreement was "good" to "very good" for all measured clinical parameters when comparing the low-dose and micro-dose protocols (ICC > 0.73). The micro-dose protocol substantially reduced the delivered dose (by a factor of 5-7 compared to the low-dose protocol) in braced children with AIS. Although image quality was reduced, the micro-dose protocol proved to be adapted to radiological follow-up, with adequate image quality and reliable clinical measurements. These slides can be retrieved under Electronic Supplementary Material.
Will X-ray Safety Glasses Become Mandatory for Radiological Vascular Interventions?
Thomas, Rohit Philip; Grau, Mathias; Eldergash, Osama; Kowald, Tobias; Schnabel, Johannes; Szczechowicz, Marcin; Chavan, Ajay
2018-07-01
The annual permissible radiation ocular lens dose has been reduced to 20 millisieverts (mSv) in the current European directive 2013/59/Euratom. The aim of this study was to evaluate the personal radiation dose for vascular interventions with special focus on ocular lens dose. From May 2016 to October 2016, the personal radiation doses of two interventionists and four technicians were prospectively recorded during 206 vascular interventions. The position of personnel, intervention type and fluoroscopy time were recorded. Parameters evaluated were total body dose measured by film dosimeter, hand dose measured by ring thermoluminescent dosimeter (TLD) and ocular lens dose measured by TLD placed in front of the safety glasses. Linear regression analysis was used to estimate the dose at 2 and 5 years. The ocular lens dose, hand and total body dose of the two interventionists were 11/5, 56/47 and 0.6 mSv each, respectively. The estimated 5-year ocular dose was 113.08 mSv (95% CI 38.2-187.97)/40.95 (95% CI 16.9-64.7). Similarly, hand dose was 608.4 mSv (95% CI 442.78-774.38)/514.47 (95% CI 329.83-699.10) and body dose 6.07 mSv (95% CI 4.70-8.22)/5.12 (95% CI 3.65-6.59), respectively. Amongst four technicians, only the first assistant showed recordings of 0.3 mSv body dose, 2 mSv ocular lens dose and 5 mSv hand dose. The yearly ocular lens dose, particularly for interventionists dealing with complex interventions, could cross the permitted yearly limit set by the new Euratom directive. Therefore, X-ray safety glasses would become mandatory for complex radiological vascular interventions. Level III, non-randomized controlled cohort/follow-up study.
Entine, F; Bensimon Etzol, J; Bettencourt, C; Dondey, M; Michel, X; Gagna, G; Gellie, G; Corre, Y; Ugolin, N; Chevillard, S; Amabile, J-C
2018-07-01
Estimation of the dose received by accidentally irradiated victims is based on a tripod: clinical, biological, and physical dosimetry. The DosiKit system is an operational and mobile biodosimetry device allowing the measurement of external irradiation directly on the site of a radiological accident. This tool is based on capillary blood sample and hair follicle collection. The aim is to obtain a whole-body and local-surface dose assessment. This paper is about the technical evaluation of the DosiKit; the analytical process and scientific validation are briefly described. The Toulon exercise scenario was based on a major accident involving the reactor of a nuclear attack submarine. The design of the scenario made it impossible for several players (firefighters, medical team) to leave the area for a long time, and they were potentially exposed to high dose rates. The DosiKit system was fully integrated into a deployable radiological emergency laboratory, and the response to operational needs was very satisfactory.
Alonso-Hernández, C M; Bernal-Castillo, J; Morera-Gómez, Y; Guillen-Arruebarrena, A; Cartas-Aguila, H A; Acosta-Milián, R
2014-03-01
The radioactivity of NORM was measured in ashes collected from a fuel-oil power plant in Cienfuegos, Cuba, using an HPGe gamma-ray spectrometer. The (226)Ra, (210)Pb, (40)K, (232)Th and (238)U activity concentrations reached 240, 77, 59, 70 and 15 Bq kg(-1), respectively. The potential radiological hazard of these residuals was assessed. The radium equivalent activities of the samples varied from 54 to 345 Bq kg(-1). The gamma index was calculated to be lower than that of the reference values, and the gamma absorbed dose rate was higher than the average reported for the earth's crust; however, the assessed annual effective dose was slightly lower than the annual effective dose limit for public, i.e. 1 mSv. Therefore, these bottom ashes were not dramatically enriched with radionuclides and may be used as an additive for building materials without restrictions from a radiological protection point of view.
An overview on GSF activities at the Semipalatinsk Test Site, Kazakhstan.
Semioshkina, Natalia; Voigt, Gabrielle
2006-02-01
The Semipalatinsk Test Site (STS) in Kazakhstan was one of the major sites used by the former USSR for testing nuclear weapons for more than 40 years. Since the early 1990s, agricultural activities have been re-established there by neighbouring collective and private farms. Therefore, it has become important to evaluate the radiological situation and the current and future risk to people living on and using the contaminated area. During the last eight years, GSF has participated in many international projects performed on the STS to evaluate the radiological situation. A large number of soil, vegetation and food samples has been collected and analysed. Internal dose is one of the main components of the total dose when deriving risk factors for a population living within the test site. Internal doses, based on food monitoring and whole body measurements, were calculated for adults and were in the range of 13-500 microSv/y due to radiocaesium and radiostrontium.
Entrance surface dose in cerebral interventional radiology procedures
NASA Astrophysics Data System (ADS)
Barrera-Rico, M.; López-Rendón, X.; Rivera-Ordóñez, C. E.; Gamboa-deBuen, I.
2012-10-01
At the Instituto Nacional de Neurología y Neurocirugía (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 ×1 cm2 of Gafchromic XR-QA2 film bound in a holder of 15×15 cm2 in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.
Entrance surface dose in cerebral interventional radiology procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barrera-Rico, M.; Lopez-Rendon, X.; Rivera-Ordonez, C. E.
2012-10-23
At the Instituto Nacional de Neurologia y Neurocirugia (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 Multiplication-Sign 1 cm{sup 2} of Gafchromic XR-QA2 film bound in a holder of 15 Multiplication-Sign 15 cm{sup 2} in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESDmore » could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.« less
NASA Astrophysics Data System (ADS)
Robinson, Alexandra R.
An updated global survey of radioisotope production and distribution was completed and subjected to a revised "down-selection methodology" to determine those radioisotopes that should be classified as potential national security risks based on availability and key physical characteristics that could be exploited in a hypothetical radiological dispersion device. The potential at-risk radioisotopes then were used in a modeling software suite known as Turbo FRMAC, developed by Sandia National Laboratories, to characterize plausible contamination maps known as Protective Action Guideline Zone Maps. This software also was used to calculate the whole body dose equivalent for exposed individuals based on various dispersion parameters and scenarios. Derived Response Levels then were determined for each radioisotope using: 1) target doses to members of the public provided by the U.S. EPA, and 2) occupational dose limits provided by the U.S. Nuclear Regulatory Commission. The limiting Derived Response Level for each radioisotope also was determined.
Enyinna, Paschal Ikenna
2016-01-01
Radiological risk parameters associated with aircrew members traveling from Houston Intercontinental Airport to Lagos International Airport have been computed using computer software called EPCARD (version 3.2). The mean annual effective dose of radiation was computed to be 2.94 mSv/year. This result is above the standard permissible limit of 1 mSv/year set for the public and pregnant aircrew members but below the limit set for occupationally exposed workers. The Risk of cancer mortality and excess career time cancer risk computed ranged from 3.5 × 10(-5) to 24.5 × 10(-5) (with average of 14.7 × 10(-5)) and 7 × 10(-4) to 49 × 10(-4) (with average of 29.4 × 10(-4)). Passengers and aircrew members should be aware of the extra cosmic radiation doses taken in during flights. All aircraft operators should monitor radiation doses incurred during aviation trips.
Enyinna, Paschal Ikenna
2016-01-01
Radiological risk parameters associated with aircrew members traveling from Houston Intercontinental Airport to Lagos International Airport have been computed using computer software called EPCARD (version 3.2). The mean annual effective dose of radiation was computed to be 2.94 mSv/year. This result is above the standard permissible limit of 1 mSv/year set for the public and pregnant aircrew members but below the limit set for occupationally exposed workers. The Risk of cancer mortality and excess career time cancer risk computed ranged from 3.5 × 10−5 to 24.5 × 10−5 (with average of 14.7 × 10−5) and 7 × 10−4 to 49 × 10−4 (with average of 29.4 × 10−4). Passengers and aircrew members should be aware of the extra cosmic radiation doses taken in during flights. All aircraft operators should monitor radiation doses incurred during aviation trips. PMID:27651568
Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka
In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guidemore » provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.« less
Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute
NASA Astrophysics Data System (ADS)
Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús
2014-11-01
In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.
Miura, Miwa; Ono, Koji; Yamauchi, Motohiro; Matsuda, Naoki
2016-06-01
From October to December 2010, just before the radiological accident at the Fukushima Daiichi nuclear power plant, 71 radiation professionals from radiation facilities in Japan were asked what they considered as a "safe dose" of radiation for themselves, their partners, parents, children, siblings, and friends. Although the 'safe dose' they noted varied widely, from less than 1 mSv y to more than 100 mSv y, the average dose was 35.6 mSv y, which is around the middle point between the legal exposure dose limits for the annual average and for any single year. Similar results were obtained from other surveys of members of the Japan Radioisotope Association (36.9 mSv y) and of the Oita Prefectural Hospital (36.8 mSv y). Among family members and friends, the minimum average "safe" dose was 8.5 mSv y for children, for whom 50% of the responders claimed a "safe dose" of less than 1 mSv. Gender, age and specialty of the radiation professional also affected their notion of a "safe dose." These findings suggest that the perception of radiation risk varies widely even for radiation professionals and that the legal exposure dose limits derived from regulatory science may act as an anchor of safety. The different levels of risk perception for different target groups among radiation professionals appear similar to those in the general population. The gap between these characteristics of radiation professionals and the generally accepted picture of radiation professionals might have played a role in the state of confusion after the radiological accident.
NASA Astrophysics Data System (ADS)
Budde, Adam; Nilsen, Roy; Nett, Brian
2014-03-01
State of the art automatic exposure control modulates the tube current across view angle and Z based on patient anatomy for use in axial full scan reconstructions. Cardiac CT, however, uses a fundamentally different image reconstruction that applies a temporal weighting to reduce motion artifacts. This paper describes a phase based mA modulation that goes beyond axial and ECG modulation; it uses knowledge of the temporal view weighting applied within the reconstruction algorithm to improve dose efficiency in cardiac CT scanning. Using physical phantoms and synthetic noise emulation, we measure how knowledge of sinogram temporal weighting and the prescribed cardiac phase can be used to improve dose efficiency. First, we validated that a synthetic CT noise emulation method produced realistic image noise. Next, we used the CT noise emulation method to simulate mA modulation on scans of a physical anthropomorphic phantom where a motion profile corresponding to a heart rate of 60 beats per minute was used. The CT noise emulation method matched noise to lower dose scans across the image within 1.5% relative error. Using this noise emulation method to simulate modulating the mA while keeping the total dose constant, the image variance was reduced by an average of 11.9% on a scan with 50 msec padding, demonstrating improved dose efficiency. Radiation dose reduction in cardiac CT can be achieved while maintaining the same level of image noise through phase based dose modulation that incorporates knowledge of the cardiac reconstruction algorithm.
NASA Astrophysics Data System (ADS)
Magalotti, D.; Bissi, L.; Conti, E.; Paolucci, M.; Placidi, P.; Scorzoni, A.; Servoli, L.
2014-01-01
Staff members applying Interventional Radiology procedures are exposed to ionizing radiation, which can induce detrimental effects to the human body, and requires an improvement of radiation protection. This paper is focused on the study of the sensor element for a wireless real-time dosimeter to be worn by the medical staff during the interventional radiology procedures, in the framework of the Real-Time Active PIxel Dosimetry (RAPID) INFN project. We characterize a CMOS imager to be used as detection element for the photons scattered by the patient body. The CMOS imager has been first characterized in laboratory using fluorescence X-ray sources, then a PMMA phantom has been used to diffuse the X-ray photons from an angiography system. Different operating conditions have been used to test the detector response in realistic situations, by varying the X-ray tube parameters (continuous/pulsed mode, tube voltage and current, pulse parameters), the sensor parameters (gain, integration time) and the relative distance between sensor and phantom. The sensor response has been compared with measurements performed using passive dosimeters (TLD) and also with a certified beam, in an accredited calibration centre, in order to obtain an absolute calibration. The results are very encouraging, with dose and dose rate measurement uncertainties below the 10% level even for the most demanding Interventional Radiology protocols.
Assessment of radiocarbon in the Savannah River Site Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlton, W.H.; Evans, A.G.; Murphy, C.E. Jr.
1993-03-01
This report is a radiological assessment of [sup 14]C releases from the Savannah River Site. During the operation of five production reactors [sup 14]C has been produced at SRS. Approximately 3000 curies have been released to the atmosphere but there are no recorded releases to surface waters. Once released, the [sup 14]C joins the carbon cycle and a portion enters the food chain. The overall radiological impact of SRS releases on the offsite maximum individual can be characterized by a dose of 1.1 mrem, compared with a dose of 12,960 mrem from non-SRS sources during the same period of time.more » Releases of [sup 14]C have resulted in a negligible risk to the environment and the population it supports.« less
Assessment of radiocarbon in the Savannah River Site Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlton, W.H.; Evans, A.G.; Murphy, C.E. Jr.
1993-03-01
This report is a radiological assessment of {sup 14}C releases from the Savannah River Site. During the operation of five production reactors {sup 14}C has been produced at SRS. Approximately 3000 curies have been released to the atmosphere but there are no recorded releases to surface waters. Once released, the {sup 14}C joins the carbon cycle and a portion enters the food chain. The overall radiological impact of SRS releases on the offsite maximum individual can be characterized by a dose of 1.1 mrem, compared with a dose of 12,960 mrem from non-SRS sources during the same period of time.more » Releases of {sup 14}C have resulted in a negligible risk to the environment and the population it supports.« less
A radiological assessment of nuclear power and propulsion operations near Space Station Freedom
NASA Technical Reports Server (NTRS)
Bolch, Wesley E.; Thomas, J. Kelly; Peddicord, K. Lee; Nelson, Paul; Marshall, David T.; Busche, Donna M.
1990-01-01
Scenarios were identified which involve the use of nuclear power systems in the vicinity of Space Station Freedom (SSF) and their radiological impact on the SSF crew was quantified. Several of the developed scenarios relate to the use of SSF as an evolutionary transportation node for lunar and Mars missions. In particular, radiation doses delivered to SSF crew were calculated for both the launch and subsequent return of a Nuclear Electric Propulsion (NEP) cargo vehicle and a Nuclear Thermal Rocket (NTR) personnel vehicle to low earth orbit. The use of nuclear power on co-orbiting platforms and the storage and handling issues associated with radioisotope power systems were also explored as they relate to SSF. A central philosophy in these analyses was the utilization of a radiation dose budget, defined as the difference between recommended dose limits from all radiation sources and estimated doses received by crew members from natural space radiations. Consequently, for each scenario examined, the dose budget concept was used to identify and quantify constraints on operational parameters such as launch separation distances, returned vehicle parking distances, and reactor shutdown times prior to vehicle approach. The results indicate that realistic scenarios do not exist which would preclude the use of nuclear power sources in the vicinity of SSF. The radiation dose to the SSF crew can be maintained at safe levels solely by implementing proper and reasonable operating procedures.
Personalized technologist dose audit feedback for reducing patient radiation exposure from CT.
Miglioretti, Diana L; Zhang, Yue; Johnson, Eric; Lee, Choonsik; Morin, Richard L; Vanneman, Nicholas; Smith-Bindman, Rebecca
2014-03-01
The aim of this study was to determine whether providing radiologic technologists with audit feedback on doses from CT examinations they conduct and education on dose-reduction strategies reduces patients' radiation exposure. This prospective, controlled pilot study was conducted within an integrated health care system from November 2010 to October 2011. Ten technologists at 2 facilities received personalized dose audit reports and education on dose-reduction strategies; 9 technologists at a control facility received no intervention. Radiation exposure was measured by the dose-length product (DLP) from CT scans performed before (n = 1,630) and after (n = 1,499) the intervention and compared using quantile regression. Technologists were surveyed before and after the intervention. For abdominal CT, DLPs decreased by 3% to 12% at intervention facilities but not at the control facility. For brain CT, DLPs significantly decreased by 7% to 12% at one intervention facility; did not change at the second intervention facility, which had the lowest preintervention DLPs; and increased at the control facility. Technologists were more likely to report always thinking about radiation exposure and associated cancer risk and optimizing settings to reduce exposure after the intervention. Personalized audit feedback and education can change technologists' attitudes about, and awareness of, radiation and can lower patient radiation exposure from CT imaging. Copyright © 2014 American College of Radiology. All rights reserved.
Pouget, J-P; Laurent, C; Delbos, M; Benderitter, M; Clairand, I; Trompier, F; Stéphanazzi, J; Carsin, H; Lambert, F; Voisin, P; Gourmelon, P
2004-10-01
We propose a new method of biodosimetry that could be applied in cases of localized irradiation. The approach is based on excess chromosome segments determination by the PCC-FISH technique in fibroblasts isolated from skin biopsy. Typically, 0 to 10 Gy ex vivo gamma-irradiated human skin biopsies were dissociated and fibroblasts were isolated and grown for several days. Cells next underwent PCC-FISH painting of whole chromosome 4, and the number of excess chromosome segments per metaphase was determined. An ex vivo reference curve correlating the number of excess chromosome segments per metaphase to the radiation dose was established and used to assess the dose delivered to the skin of one of the victims of the radiological accident that occurred at Lia in Georgia in December 2001. Specifically, the victim suffering from moist desquamation underwent skin excision in Hospital Percy (France). Measurement of excess chromosome segments per metaphase was done in fibroblasts isolated and grown from removed wounded skin and subsequent conversion to radiation doses was performed. The radiation dose map obtained was shown to be in accordance with clinical data and physical dosimetry as well as with conventional biodosimetry. These results demonstrated that PCC-FISH painting applied to skin fibroblasts may be a suitable technique for dose estimation. To assess its worth, this approach needs to be extended to future accidents involving localized radiation exposure.
Commentary: Ethical Issues of Current Health-Protection Policies on Low-Dose Ionizing Radiation
Socol, Yehoshua; Dobrzyński, Ludwik; Doss, Mohan; Feinendegen, Ludwig E.; Janiak, Marek K.; Miller, Mark L.; Sanders, Charles L.; Scott, Bobby R.; Ulsh, Brant; Vaiserman, Alexander
2014-01-01
The linear no-threshold (LNT) model of ionizing-radiation-induced cancer is based on the assumption that every radiation dose increment constitutes increased cancer risk for humans. The risk is hypothesized to increase linearly as the total dose increases. While this model is the basis for radiation safety regulations, its scientific validity has been questioned and debated for many decades. The recent memorandum of the International Commission on Radiological Protection admits that the LNT-model predictions at low doses are “speculative, unproven, undetectable and ‘phantom’.” Moreover, numerous experimental, ecological, and epidemiological studies show that low doses of sparsely-ionizing or sparsely-ionizing plus highly-ionizing radiation may be beneficial to human health (hormesis/adaptive response). The present LNT-model-based regulations impose excessive costs on the society. For example, the median-cost medical program is 5000 times more cost-efficient in saving lives than controlling radiation emissions. There are also lives lost: e.g., following Fukushima accident, more than 1000 disaster-related yet non-radiogenic premature deaths were officially registered among the population evacuated due to radiation concerns. Additional negative impacts of LNT-model-inspired radiophobia include: refusal of some patients to undergo potentially life-saving medical imaging; discouragement of the study of low-dose radiation therapies; motivation for radiological terrorism and promotion of nuclear proliferation. PMID:24910586
Radiation dose reduction in a neonatal intensive care unit in computed radiography.
Frayre, A S; Torres, P; Gaona, E; Rivera, T; Franco, J; Molina, N
2012-12-01
The purpose of this study was to evaluate the dose received by chest x-rays in neonatal care with thermoluminescent dosimetry and to determine the level of exposure where the quantum noise level does not affect the diagnostic image quality in order to reduce the dose to neonates. In pediatric radiology, especially the prematurely born children are highly sensitive to the radiation because of the highly mitotic state of their cells; in general, the sensitivity of a tissue to radiation is directly proportional to its rate of proliferation. The sample consisted of 208 neonatal chest x-rays of 12 neonates admitted and treated in a Neonatal Intensive Care Unit (NICU). All the neonates were preterm in the range of 28-34 weeks, with a mean of 30.8 weeks. Entrance Surface Doses (ESD) values for chest x-rays are higher than the DRL of 50 μGy proposed by the National Radiological Protection Board (NRPB). In order to reduce the dose to neonates, the optimum image quality was achieved by determining the level of ESD where level noise does not affect the diagnostic image quality. The optimum ESD was estimated for additional 20 chest x-rays increasing kVp and reducing mAs until quantum noise affects image quality. Copyright © 2012 Elsevier Ltd. All rights reserved.
Comprehensive optimization process of paranasal sinus radiography.
Saarakkala, S; Nironen, K; Hermunen, H; Aarnio, J; Heikkinen, J O
2009-04-01
The optimization of radiological examinations is important in order to reduce unnecessary patient radiation exposure. To perform a comprehensive optimization process for paranasal sinus radiography at Mikkeli Central Hospital, Finland. Patients with suspicion of acute sinusitis were imaged with a Kodak computed radiography (CR) system (n=20) and with a Philips digital radiography (DR) system (n=30) using focus-detector distances (FDDs) of 110 cm, 150 cm, or 200 cm. Patients' radiation exposure was determined in terms of entrance surface dose and dose-area product. Furthermore, an anatomical phantom was used for the estimation of point doses inside the head. Clinical image quality was evaluated by an experienced radiologist, and physical image quality was evaluated from the digital radiography phantom. Patient doses were significantly lower and image quality better with the DR system compared to the CR system. The differences in patient dose and physical image quality were small with varying FDD. Clinical image quality of the DR system was lowest with FDD of 200 cm. Further, imaging with FDD of 150 cm was technically easier for the technologist to perform than with FDD of 110 cm. After optimization, it was recommended that the DR system with FDD of 150 cm should always be used at Mikkeli Central Hospital. We recommend this kind of comprehensive approach in all optimization processes of radiological examinations.
Browns Ferry Nuclear Plant radiological impact assessment report, January-June 1988
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, B.E.
1988-01-01
Potential doses to maximum individuals and the population around Browns Ferry are calcuated for each quarter. Measured plant releases for the reporting period are used to estimate these doses. Dispersion of radioactive effluents in the environment is estimated in accordance with the guidance provided and measuring during the period. Using dose calculation methodologies which are described in detail in the Browns Ferry Offsite Dose Calculation Manual, the doses are calculated and used to determine compliance with the dose limits contained in Browns Ferry's Operating License. In this report, the doses resulting from releases are described and compared to quarterly andmore » annual limits established for Browns Ferry.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, W; National Institute of Radiological Sciences, Chiba, Chiba; Koba, Y
Purpose: To measure the absorbed dose to water Dw in therapeutic proton beam with radiophotoluminescent glass dosimeter (RGD), a methodology was proposed. In this methodology, the correction factor for the LET dependence of radiophotoluminescent (RPL) efficiency and the variation of mass stopping power ratio of water to RGD (SPRw, RGD) were adopted. The feasibility of proposed method was evaluated in this report. Methods: The calibration coefficient in terms of Dw for RGDs (GD-302M, Asahi Techno Glass) was obtained using 60Co beam. The SPRw, RGD was calculated by Monte Carlo simulation toolkit Geant4. The LET dependence of RPL efficiency was investigatedmore » experimentally by using a 70 MeV proton beam at National Institute of Radiological Sciences. For clinical usage, the residual range Rres was used as a quality index to determine the correction factor for RPL efficiency. The proposed method was evaluated by measuring Dw at difference depth in the 200 MeV proton beam. Results: For both modulated and non-modulated proton beam, the SPRw, RGD increases more than 3 % where Rres are less than 1 cm. RPL efficiency decreases with increasing LET and it reaches 0.6 at LET of 10 keV µm{sup −1}. Dw measured by RGD (Dw, RGD) shows good agreement with that measured by ionization chamber (Dw, IC) and the relative difference between Dw, RGD and Dw, IC are within 3 % where Rres is larger than 1 cm. Conclusion: In this work, a methodology for using RGD in proton dosimetry was proposed and the SPRw, RGD and the LET dependence of RPL efficiency in therapeutic proton beam was investigated. The results revealed that the proposed method is useful for RGD in the dosimetry of proton beams.« less
An Integrated Interactive-Spaced Education Radiology Curriculum for Preclinical Students.
Tshibwabwa, Eli; Mallin, Robert; Fraser, Madeleine; Tshibwabwa, Martin; Sanii, Reza; Rice, James; Cannon, Jenifer
2017-01-01
The objective of this study is to determine whether a radiology module, together with online spaced education, helps students of an integrated problem-based learning (PBL) curriculum increase their radiology knowledge and long-term retention. Second-year students at the American University of Antigua College of Medicine participated in small groups of ten students each into two 2 h of radiology laboratories. The study comprised two cohorts: winter and fall 2013 students (control group) and 2014 students (experimental group). Both groups used face-to-face PBL. The students of the experimental group received additional online-spaced education. The skills were assessed for both groups before the beginning of laboratories and 4 weeks and 7 months after laboratories. There was no significant difference on pretest between the control and experimental groups. On completion of the radiology laboratories, comparison of test results before and after training showed net improvement for both groups. The corresponding difference for the experimental group was higher compared to the one for the control group (7.83 vs. 6.21, P < 0.001). The difference between the scores on delayed test and pretest showed that the students of both groups demonstrated average knowledge improvement even though their level of performance was slightly below the posttest. The corresponding difference for the experimental group did not differ much from the posttest ( P > 0.05), and no significant difference of scores was observed 7 months later for either group. Further, a higher percentage of the students in the experimental group strongly agreed that their learning objectives were met (92% vs. 71%, P > 0.001), and this trend persisted throughout the study. Online spaced education combined to a face-to-face PBL enhances not only the student's knowledge of basic radiology along with his/her self-assessment skills but also the long-term retention of radiology material and satisfaction with the integrated interactive system-based module. Future research is needed to see if medical students in need of additional education support may benefit from spaced education in the field of remediation.
Huang, Yang; Lowe, Henry J; Klein, Dan; Cucina, Russell J
2005-01-01
The aim of this study was to develop and evaluate a method of extracting noun phrases with full phrase structures from a set of clinical radiology reports using natural language processing (NLP) and to investigate the effects of using the UMLS(R) Specialist Lexicon to improve noun phrase identification within clinical radiology documents. The noun phrase identification (NPI) module is composed of a sentence boundary detector, a statistical natural language parser trained on a nonmedical domain, and a noun phrase (NP) tagger. The NPI module processed a set of 100 XML-represented clinical radiology reports in Health Level 7 (HL7)(R) Clinical Document Architecture (CDA)-compatible format. Computed output was compared with manual markups made by four physicians and one author for maximal (longest) NP and those made by one author for base (simple) NP, respectively. An extended lexicon of biomedical terms was created from the UMLS Specialist Lexicon and used to improve NPI performance. The test set was 50 randomly selected reports. The sentence boundary detector achieved 99.0% precision and 98.6% recall. The overall maximal NPI precision and recall were 78.9% and 81.5% before using the UMLS Specialist Lexicon and 82.1% and 84.6% after. The overall base NPI precision and recall were 88.2% and 86.8% before using the UMLS Specialist Lexicon and 93.1% and 92.6% after, reducing false-positives by 31.1% and false-negatives by 34.3%. The sentence boundary detector performs excellently. After the adaptation using the UMLS Specialist Lexicon, the statistical parser's NPI performance on radiology reports increased to levels comparable to the parser's native performance in its newswire training domain and to that reported by other researchers in the general nonmedical domain.
Giri, Soma; Jha, V N; Singh, Gurdeep; Tripathi, R M
2013-12-01
To study the distribution of (210)Po, (226)Ra, (230)Th and U(nat) (naturally occurring radioisotopes of uranium [(234)U, (235)U and (238)U]) in food and water around the Bagjata uranium mining area in India. Radionuclides were analyzed in food samples of plant and animal origin after acid digestion. Intake and ingestion dose of the radionuclides were estimated. (210)Po, (226)Ra, (230)Th and U(nat) in all the dietary components ranged widely from < 0.2-36, < 0.02-1.58, < 0.01-2.8 and < 0.017-0.39 Bqkg(-1), respectively. The range of (226)Ra and U(nat) in water was < 3.5-206 and < 12.6-693 mBql(-1), respectively. The intake of radionuclides considering food and water was calculated to be 760 BqY(-1) while the ingestion dose was 601 μSvY(-1). The estimated doses reflect the natural background dose via route of ingestion, which is below the 1 mSvY(-1) limit set by the International Commission on Radiological Protection (ICRP). However, the doses are more than the dose constraint of 300 μSvY(-1) as suggested by the ICRP for members of the public for planned disposal of long-lived radioactive waste. The study confirms that current levels of radionuclides do not pose significant radiological risk to the local inhabitants, but they need close investigation in the near future.
Eye lens dose in interventional cardiology.
Principi, S; Delgado Soler, C; Ginjaume, M; Beltran Vilagrasa, M; Rovira Escutia, J J; Duch, M A
2015-07-01
The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y(-1), averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y(-1). This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs): one calibrated in terms of Hp(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of Hp(10) and Hp(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y(-1). Lower doses were collected for nurses, with estimated annual Hp(3) between 2 and 4 mSv y(-1). It was observed that for nurses the Hp(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between Hp(3) and dose area product is shown. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Neutron fluence-to-dose conversion coefficients for embryo and fetus.
Chen, Jing; Meyerhof, Dorothy; Vlahovich, Slavica
2004-01-01
A problem of concern in radiation protection is the exposure of pregnant women to ionising radiation, because of the high radiosensitivity of the embryo and fetus. External neutron exposure is of concern when pregnant women travel by aeroplane. Dose assessments for neutrons frequently rely on fluence-to-dose conversion coefficients. While neutron fluence-to-dose conversion coefficients for adults are recommended in International Commission on Radiological Protection publications and International Commission on Radiological Units and Measurements reports, conversion coefficients for embryos and fetuses are not given in the publications. This study undertakes Monte Carlo calculations to determine the mean absorbed doses to the embryo and fetus when the mother is exposed to neutron fields. A new set of mathematical models for the embryo and fetus has been developed at Health Canada and is used together with mathematical phantoms of a pregnant female developed at Oak Ridge National Laboratory. Monoenergetic neutrons from 1 eV to 10 MeV are considered in this study. The irradiation geometries include antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT) and isotropic (ISO) geometries. At each of these standard irradiation geometries, absorbed doses to the fetal brain and body are calculated; for the embryo at 8 weeks and the fetus at 3, 6 or 9 months. Neutron fluence-to-absorbed dose conversion coefficients are derived for the four age groups. Neutron fluence-to-equivalent dose conversion coefficients are given for the AP irradiations which yield the highest radiation dose to the fetal body in the neutron energy range considered here. The results indicate that for neutrons <10 MeV more protection should be given to pregnant women in the first trimester due to the higher absorbed dose per unit neutron fluence to the fetus.
Concept of proton radiography using energy resolved dose measurement.
Bentefour, El H; Schnuerer, Roland; Lu, Hsiao-Ming
2016-08-21
Energy resolved dosimetry offers a potential path to single detector based proton imaging using scanned proton beams. This is because energy resolved dose functions encrypt the radiological depth at which the measurements are made. When a set of predetermined proton beams 'proton imaging field' are used to deliver a well determined dose distribution in a specific volume, then, at any given depth x of this volume, the behavior of the dose against the energies of the proton imaging field is unique and characterizes the depth x. This concept applies directly to proton therapy scanning delivery methods (pencil beam scanning and uniform scanning) and it can be extended to the proton therapy passive delivery methods (single and double scattering) if the delivery of the irradiation is time-controlled with a known time-energy relationship. To derive the water equivalent path length (WEPL) from the energy resolved dose measurement, one may proceed in two different ways. A first method is by matching the measured energy resolved dose function to a pre-established calibration database of the behavior of the energy resolved dose in water, measured over the entire range of radiological depths with at least 1 mm spatial resolution. This calibration database can also be made specific to the patient if computed using the patient x-CT data. A second method to determine the WEPL is by using the empirical relationships between the WEPL and the integral dose or the depth at 80% of the proximal fall off of the energy resolved dose functions in water. In this note, we establish the evidence of the fundamental relationship between the energy resolved dose and the WEPL at the depth of the measurement. Then, we illustrate this relationship with experimental data and discuss its imaging dynamic range for 230 MeV protons.
NASA Astrophysics Data System (ADS)
Karim, M. K. A.; Hashim, S.; Bradley, D. A.; Bahruddin, N. A.; Ang, W. C.; Salehhon, N.
2016-03-01
In this paper, we evaluate the level of knowledge and awareness among 120 radiology personnel working in 7 public hospitals in Johor, Malaysia, concerning Computed Tomography (CT) technology and radiation doses based on a set of questionnaires. Subjects were divided into two groups (Medical profession (Med, n=32) and Allied health profession (AH, n=88). The questionnaires are addressed: (1) demographic data (2) relative radiation dose and (3) knowledge of current CT technology. One-third of respondents from both groups were able to estimate relative radiation dose for routine CT examinations. 68% of the allied health profession personnel knew of the Malaysia regulations entitled ‘Basic Safety Standard (BSS) 2010’, although notably 80% of them had previously attended a radiation protection course. No significant difference (p < 0.05) in mean scores of CT technology knowledge detected between the two groups, with the medical professions producing a mean score of (26.7 ± 2.7) and the allied health professions a mean score of (25.2 ± 4.3). This study points to considerable variation among the respondents concerning their understanding of knowledge and awareness of risks of radiation and CT optimization techniques.
NASA Astrophysics Data System (ADS)
Caridi, F.; Marguccio, S.; Durante, G.; Trozzo, R.; Fullone, F.; Belvedere, A.; D'Agostino, M.; Belmusto, G.
2017-01-01
In this article natural radioactivity measurements and dosimetric evaluations in soil samples contaminated by Naturally Occurring Radioactive Materials (NORM) are made, in order to assess any possible radiological hazard for the population and for workers professionally exposed to ionizing radiations. Investigated samples came from the district of Crotone, Calabria region, South of Italy. The natural radioactivity investigation was performed by high-resolution gamma-ray spectrometry. From the measured gamma spectra, activity concentrations were determined for 226Ra , 234-mPa , 224Ra , 228Ac and 40K and compared with their clearance levels for NORM. The total effective dose was calculated for each sample as due to the committed effective dose for inhalation and to the effective dose from external irradiation. The sum of the total effective doses estimated for all investigated samples was compared to the action levels provided by the Italian legislation (D.Lgs.230/95 and subsequent modifications) for the population members (0.3mSv/y) and for professionally exposed workers (1mSv/y). It was found to be less than the limit of no radiological significance (10μSv/y).
Fadol, Nooreldin; Idriss, Hajo; Salih, Isam; Ragab, Nserdin A; Osman, Safa; Sam, Adam K
2018-06-01
This study was conducted to assess the level of radioactivity and the radiation hazards associated with granite rocks used for construction of buildings. The measurement of radioactivity content of the rock samples was performed with gamma-spectrometry equipped with Nal (TI) detector. From the results obtained in this study the average activity concentrations of 226Ra, 232Th and 40K were 20.64, 30.50 and 295.19 Bq kg-1, respectively. The absorbed dose rate in air at 1 m above ground level, the annual effective dose and the gamma index were determined with the aim to assess the possible radiological impact on inhabitants of dwellings built using such rocks. The mean value of the absorbed dose rate, the annual effective dose and the gamma index (Iγ) was 36.36 nGy h-1, 40.79 μSv y-1 and 0.51 μSv y-1, respectively. Radium equivalent activities, and external and internal hazard indices, were also calculated. These data indicated that the area of study lies within areas recognized as normal background radiation and the granite rocks are safe to be used as building material and other structural purposes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pelletier, C; Jung, J; Lee, C
Purpose: Epidemiological study of second cancer risk for cancer survivors often requires the dose to normal tissues located outside the anatomy covered by radiological imaging, which is usually limited to tumor and organs at risk. We have investigated the feasibility of using whole body computational human phantoms for estimating out-of-field organ doses for patients treated by Intensity Modulated Radiation Therapy (IMRT). Methods: Identical 7-field IMRT prostate plans were performed using X-ray Voxel Monte Carlo (XVMC), a radiotherapy-specific Monte Carlo transport code, on the computed tomography (CT) images of the torso of an adult male patient (175 cm height, 66 kgmore » weight) and an adult male hybrid computational phantom with the equivalent body size. Dose to the liver, right lung, and left lung were calculated and compared. Results: Considerable differences are seen between the doses calculated by XVMC for the patient CT and the hybrid phantom. One major contributing factor is the treatment method, deep inspiration breath hold (DIBH), used for this patient. This leads to significant differences in the organ position relative to the treatment isocenter. The transverse distances from the treatment isocenter to the inferior border of the liver, left lung, and right lung are 19.5cm, 29.5cm, and 30.0cm, respectively for the patient CT, compared with 24.3cm, 36.6cm, and 39.1cm, respectively, for the hybrid phantom. When corrected for the distance, the mean doses calculated using the hybrid phantom are within 28% of those calculated using the patient CT. Conclusion: This study showed that mean dose to the organs located in the missing CT coverage can be reconstructed by using whole body computational human phantoms within reasonable dosimetric uncertainty, however appropriate corrections may be necessary if the patient is treated with a technique that will significantly deform the size or location of the organs relative to the hybrid phantom.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bosmans, H; Van Peteghem, N; Creten, S
Purpose: In 2013, the EURATOM authorities of the European Commission decided to support the Horizon2020 project submission ‘EUTEMPE-RX’ that aimed for a new set of course modules to train medical physicists in diagnostic and interventional radiology to expert level with small group deep learning. Each module would consist of 2 phases: an e-learning and a face-to-face phase, each phase requiring typically 40h of participant time. Methods: The European Federation (EFOMP) and 13 European partners, all of them selected for their excellent scientific and/or educational skills, led the 12 course modules. A quality manual ensured the quality of course content andmore » organization. Educational workshops familiarized the teachers with e-learning techniques and methods for assessment. Content was set in accordance with the EC document RP174 that lists learning outcomes in terms of knowledge, skills and competences (KSCs) for different specialties and levels of medical physics. Surveys for stake holder satisfaction were prepared. Results: Today the course modules are being realized. The modules cover most of the KSCs in RP174 document. Teachers have challenged the participants with unique tasks: case studies in medical physics leadership, Monte Carlo simulation of a complete x-ray imaging chain, development of a task specific QA protocol, compilation of optimization plans, simulation tasks with anthropomorphic breast models, etc. Participants undertook practical sessions in modern hospitals and visited a synchrotron facility, a calibration lab, screening organizations, etc. Feedback form quality surveys was very positive and constructive. A sustainability plan has been worked out. Conclusion: The modules have enabled the participants to develop their KSCs and cope with challenges in medical physics. The sustainability plan will be implemented to continue the unique combined e-learning and face to face training at high level training in diagnostic and interventional radiology also beyond Europe. The EUTEMPE-RX project is funded by the Horizon2020 - EURATOM program of the European Commission.« less
Patient dosimetry audit for establishing local diagnostic reference levels for nuclear medicine CT.
Gardner, Matthew; Katsidzira, Ngonidzashe M; Ross, Erin; Larkin, Elizabeth A
2017-03-01
To establish a system for patient dosimetry audit and setting of local diagnostic reference levels (LDRLs) for nuclear medicine (NM) CT. Computed radiological information system (CRIS) data were matched with NM paper records, which provided the body region and dose mode for NMCT carried out at a large UK hospital. It was necessary to divide data in terms of the NM examination type, body region and dose mode. The mean and standard deviation dose-length products (DLPs) for common NMCT examinations were then calculated and compared with the proposed National Diagnostic Reference Levels (NDRLs). Only procedures which have 10 or more patients will be used to suggest LDRLs. For most examinations, the mean DLPs do not exceed the proposed NDRLs. The bone single-photon emission CT/CT lumbar spine data clearly show the need to divide data according to the purpose of the scan (dose mode), with mean (±standard error) DLPs ranging from 51 ± 5 mGy cm (low dose) to 1086 ± 124 mGy cm (metal dose). A system for NMCT patient dose audit has been developed, but there are non-trivial challenges which make the process labour intensive. These include limited information provided by CRIS downloads, dependence on paper records and limited number of examinations available owing to the need to subdivide data. Advances in knowledge: This article demonstrates that a system can be developed for NMCT patient dose audit, but also highlights the challenges associated with such audit, which may not be encountered with more routine audit of radiology CT.
Prognostic factors in prostate cancer patients treated by radical external beam radiotherapy.
Garibaldi, Elisabetta; Gabriele, Domenico; Maggio, Angelo; Delmastro, Elena; Garibaldi, Monica; Russo, Filippo; Bresciani, Sara; Stasi, Michele; Gabriele, Pietro
2017-09-01
The aim of this paper was to analyze, retrospectively, in prostate cancer patients treated in our Centre with external beam radiotherapy, the prognostic factors and their impact on the outcome in terms of cancer-specific survival (CSS), biochemical disease-free survival (BDFS) and clinical disease-free survival (CDFS). From October 1999 and March 2012, 1080 patients were treated with radiotherapy at our Institution: 87% of them were classified as ≤cT2, 83% had a Gleason Score (GS) ≤7, their mean of iPSA was 18 ng/mL, and the rate of clinical positive nodes was 1%. The mean follow-up was 81 months. The statistically significant prognostic factors for all groups of patients at both, univariate and multivariate analysis, were the GS and the iPSA. In intermediate- and high- or very-high-risk patients at multivariate analysis other prognostic factors for CSS were positive nodes on computed tomography (CT) scan and rectal preparation during the treatment; for BDFS, the prognostic factors were patient risk classification, positive lymph nodes on CT scan and rectal/bladder preparation; for CDFS, the prognostic factors were the number of positive core on biopsy (P=0.003), positive lymph nodes on CT scan, and radiotherapy (RT) dose. In high/very-high risk patient group at multivariate analysis other prognostic factors for CSS were clinical/radiological stage and RT dose, for BDFS they were adjuvant hormone therapy, clinical/radiological stage, and RT dose >77.7 Gy, and for CDFS they were clinical/radiological stage and RT dose >77.7 Gy. The results of this study confirm the prognostic factors described in the recent literature, with the addition of rectal/bladder preparation, generally known for its effect on toxicity but not yet on outcome.
Organ dose conversion coefficients for tube current modulated CT protocols for an adult population
NASA Astrophysics Data System (ADS)
Fu, Wanyi; Tian, Xiaoyu; Sahbaee, Pooyan; Zhang, Yakun; Segars, William Paul; Samei, Ehsan
2016-03-01
In computed tomography (CT), patient-specific organ dose can be estimated using pre-calculated organ dose conversion coefficients (organ dose normalized by CTDIvol, h factor) database, taking into account patient size and scan coverage. The conversion coefficients have been previously estimated for routine body protocol classes, grouped by scan coverage, across an adult population for fixed tube current modulated CT. The coefficients, however, do not include the widely utilized tube current (mA) modulation scheme, which significantly impacts organ dose. This study aims to extend the h factors and the corresponding dose length product (DLP) to create effective dose conversion coefficients (k factor) database incorporating various tube current modulation strengths. Fifty-eight extended cardiac-torso (XCAT) phantoms were included in this study representing population anatomy variation in clinical practice. Four mA profiles, representing weak to strong mA dependency on body attenuation, were generated for each phantom and protocol class. A validated Monte Carlo program was used to simulate the organ dose. The organ dose and effective dose was further normalized by CTDIvol and DLP to derive the h factors and k factors, respectively. The h factors and k factors were summarized in an exponential regression model as a function of body size. Such a population-based mathematical model can provide a comprehensive organ dose estimation given body size and CTDIvol. The model was integrated into an iPhone app XCATdose version 2, enhancing the 1st version based upon fixed tube current modulation. With the organ dose calculator, physicists, physicians, and patients can conveniently estimate organ dose.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perez-Sanchez, Danyl
As a result of a pilot project developed at the old Spanish 'Junta de Energia Nuclear' to extract uranium from ores, tailings materials were generated. Most of these residual materials were sent back to different uranium mines, but a small amount of it was mixed with conventional building materials and deposited near the old plant until the surrounding ground was flattened. The affected land is included in an area under institutional control and used as recreational area. At the time of processing, uranium isotopes were separated but other radionuclides of the uranium decay series as Th-230, Ra-226 and daughters remainmore » in the residue. Recently, the analyses of samples taken at different ground's depths confirmed their presence. This paper presents the methodology used to calculate the derived concentration level to ensure that the reference dose level of 0.1 mSv y-1 used as radiological criteria. In this study, a radiological impact assessment was performed modeling the area as recreational scenario. The modelization study was carried out with the code RESRAD considering as exposure pathways, external irradiation, inadvertent ingestion of soil, inhalation of resuspended particles, and inhalation of radon (Rn-222). As result was concluded that, if the concentration of Ra-226 in the first 15 cm of soil is lower than, 0.34 Bq g{sup -1}, the dose would not exceed the reference dose. Applying this value as a derived concentration level and comparing with the results of measurements on the ground, some areas with a concentration of activity slightly higher than latter were found. In these zones the remediation proposal has been to cover with a layer of 15 cm of clean material. This action represents a reduction of 85% of the dose and ensures compliance with the reference dose. (authors)« less
Determining a pre-mining radiological baseline from historic airborne gamma surveys: a case study.
Bollhöfer, Andreas; Beraldo, Annamarie; Pfitzner, Kirrilly; Esparon, Andrew; Doering, Che
2014-01-15
Knowing the baseline level of radioactivity in areas naturally enriched in radionuclides is important in the uranium mining context to assess radiation doses to humans and the environment both during and after mining. This information is particularly useful in rehabilitation planning and developing closure criteria for uranium mines as only radiation doses additional to the natural background are usually considered 'controllable' for radiation protection purposes. In this case study we have tested whether the method of contemporary groundtruthing of a historic airborne gamma survey could be used to determine the pre-mining radiological conditions at the Ranger mine in northern Australia. The airborne gamma survey was flown in 1976 before mining started and groundtruthed using ground gamma dose rate measurements made between 2007 and 2009 at an undisturbed area naturally enriched in uranium (Anomaly 2) located nearby the Ranger mine. Measurements of (226)Ra soil activity concentration and (222)Rn exhalation flux density at Anomaly 2 were made concurrent with the ground gamma dose rate measurements. Algorithms were developed to upscale the ground gamma data to the same spatial resolution as the historic airborne gamma survey data using a geographic information system, allowing comparison of the datasets. Linear correlation models were developed to estimate the pre-mining gamma dose rates, (226)Ra soil activity concentrations, and (222)Rn exhalation flux densities at selected areas in the greater Ranger region. The modelled levels agreed with measurements made at the Ranger Orebodies 1 and 3 before mining started, and at environmental sites in the region. The conclusion is that our approach can be used to determine baseline radiation levels, and provide a benchmark for rehabilitation of uranium mines or industrial sites where historical airborne gamma survey data are available and an undisturbed radiological analogue exists to groundtruth the data. © 2013.
International Arctic Seas Assessment Project.
Sjöblom, K L; Salo, A; Bewers, J M; Cooper, J; Dyer, R S; Lynn, N M; Mount, M E; Povinec, P P; Sazykina, T G; Schwarz, J; Scott, E M; Sivintsev, Y V; Tanner, J E; Warden, J M; Woodhead, D
1999-09-30
The International Atomic Energy Agency responded to the news that the former Soviet Union had dumped radioactive wastes in the shallow waters of the Arctic Seas, by launching the International Arctic Seas Assessment Project in 1993. The project had two objectives: to assess the risks to human health and to the environment associated with the radioactive wastes dumped in the Kara and Barents Seas; and to examine possible remedial actions related to the dumped wastes and to advise on whether they are necessary and justified. The current radiological situation in the Arctic waters was examined to assess whether there is any evidence for releases from the dumped waste. Potential future releases from the dumped wastes were predicted, concentrating on the high-level waste objects containing the major part of the radionuclide inventory of the wastes. Environmental transport of released radionuclides was modelled and the associated radiological impact on humans and the biota was assessed. The feasibility, costs and benefits of possible remedial measures applied to a selected high-level waste object were examined. Releases from identified dumped objects were found to be small and localised to the immediate vicinity of the dumping sites. Projected future annual doses to members of the public in typical local population groups were very small, less than 1 microSv--corresponding to a trivial risk. Projected future doses to a hypothetical group of military personnel patrolling the foreshore of the fjords in which wastes have been dumped were higher, up to 4 mSv/year, which still is of the same order as the average annual natural background dose. Moreover, since any of the proposed remedial actions were estimated to cost several million US$ to implement, remediation was not considered justified on the basis of potentially removing a collective dose of 10 man Sv. Doses calculated to marine fauna were insignificant, orders of magnitude below those at which detrimental effects on fauna populations might be expected to occur. Remediation was thus concluded not to be warranted on radiological grounds.
SU-E-I-95: Personalized Radiography Technical Parameters for Each Patient and Exam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soares, F; Camozzato, T; Kahl, G
Purpose: To determine exact electrical parameters (kV, mAs) a radiological technologist shall use taking account the exam and patient's structure, with guarantee of minimum dose and adequate quality image. Methods: A patient's absorbed dose equation was developed by means of Entrance Skin Dose (ESD), irradiated area and patient width for specific anatomy. ESD is calculated from a developed equation, where entrance surface air-KERMA and backscatter factor are included, with air-to-skin coefficient conversion. We developed specific Lambert-Beer attenuation equations derived from mass energy-absorption coefficients data for skin, fat, and muscle and bone as one tissue. Anatomy tissue thickness distribution at centralmore » X-ray location in anteroposterior incidence for hand and chest, was estimate by discounting constant skin and bone thickness from patient measured width, assuming the result as muscle and fat. A clinical research at a big hospital were executed when real parameters (kV, mAs, filtration, ripple) used by technologists were combined with the image quality and patient's data: anatomy width, height and weight. A correlation among the best images acquired and electrical parameters used were confronted with patient's data and dose estimation. The best combinations were used as gold standards. Results: For each anatomy, two equations were developed to calculate voltage (kV) and exposure (mAs) to reproduce and interpolate the gold standards. Patient is measured and data are input into equations, giving radiological technologists the right set of electrical parameters for that specific exam. Conclusion: This work indicates that radiological technologist can personalize the exact electrical parameters for each patient exam, instead of using standard values. It also guarantee that patients under or over-sized measures will receive the right dose for the best image. It will stop wrong empiric adjusts technologists do when examining a non-standard patient and reduce probability of radiography retaken because of over or under exposition.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coen, John J., E-mail: jcoen@partners.org; Bae, Kyounghwa; Zietman, Anthony L.
Purpose: Several randomized trials have shown a benefit of dose escalation to 78 to 79 Gy for men treated with external radiation for localized prostate cancer. Single-institution data suggest a benefit with even higher doses. American College of Radiology 03-12 is a Phase II trial testing the safety and efficacy of 82 GyE (Gray equivalent) delivered with conformal proton radiation. Methods and Materials: From 2003-2006, 85 men with localized prostate cancer were accrued to American College of Radiology 03-12. Eighty-four were eligible for analysis. They were treated with conformal proton radiation alone to a total dose of 82 GyE. Themore » study was designed to test whether the rate of 18-month Grade 3+ late toxicity was greater than 10%. Results: The median follow-up was 31.6 months. Regarding treatment-related acute toxicity, there were 39 Grade 1 cases (46%), 19 Grade 2 cases (23%) and 2 Grade 3 cases (2%). Regarding genitourinary/gastrointestinal toxicity, there were 42 Grade 1 cases (50%), 12 Grade 2 cases (14%) and 1 Grade 3 case (1%). Regarding late toxicity, there were 28 Grade 1 cases (33%), 22 Grade 2 cases (26%), 6 Grade 3 cases (7%), and 1 Grade 4 case (1%). The late genitourinary/gastrointestinal rates were the same. The estimated rate of Grade 3+ late toxicity at 18 months was 6.08%. Conclusions: Although not free of late toxicity, 82 GyE at 2 GyE per fraction delivered with conformal proton radiation did not exceed the late morbidity target tested in this trial. There was sufficient morbidity, however, that this may be the maximal dose that can be delivered safely with this technique and fractionation.« less
NASA Astrophysics Data System (ADS)
Turák, O.; Osvay, M.; Ballay, L.
2012-09-01
Radiation exposure of medical staff during cardiological and radiological procedures was investigated. The exposure of medical staff is directly connected to patient exposure. The aim of this study was to determine the distribution of doses on uncovered part of body of medical staff using LiF thermoluminescent (TL) dosimeters in seven locations. Individual Kodak film dosimeters (as authorized dosimetry system) were used for the assessment of medical staff's effective dose. Results achieved on dose distribution measurements confirm that wearing only one film badge under the lead apron does not provide enough information on the personal dose. The value of estimated annual doses on eye lens and extremities (fingers) were in good correlation with international publications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holmes, W.G.
2001-08-16
The offsite radiological effects from high velocity straight winds, tornadoes, and earthquakes have been estimated for a proposed facility for manufacturing enriched uranium fuel cores by powder metallurgy. Projected doses range up to 30 mrem/event to the maximum offsite individual for high winds and up to 85 mrem/event for very severe earthquakes. Even under conservative assumptions on meteorological conditions, the maximum offsite dose would be about 20 per cent of the DOE limit for accidents involving enriched uranium storage facilities. The total dose risk is low and is dominated by the risk from earthquakes. This report discusses this test.
Linearity and reproducibility response of Fricke dosimetry for low energy X-Ray beam
NASA Astrophysics Data System (ADS)
Mantuano, A.; de Amorim, G. J.; David, M. G.; Rosado, P. H. G.; Salata, C.; Magalhães, L. A. G.; deAlmeida, C. E.
2018-03-01
The Fricke dosimeter is the most used, liquid chemical dosimeter. It has been shown to be a feasible option for the absorbed dose standard. The present work aims to determinate a dose-response curve of Fricke solution using different doses and reproducibility test comparing the calculated dose to Fricke solution and Ionizing Chamber. Tests were performed using an X-ray irradiator for biological research at Radiological Science Laboratory (LCR/UERJ). The results showed a linear response to different doses of type A uncertainties from 0.08 to 1.2%. Reproducibility test showed type A uncertainties of 0.16% to the dosimeter.
Heilmaier, C; Mayor, A; Zuber, N; Fodor, P; Weishaupt, D
2016-03-01
Non-radiological medical professionals often need to remain in the scanning room during computed tomography (CT) examinations to supervise patients in critical condition. Independent of protective devices, their position significantly influences the radiation dose they receive. The purpose of this study was to assess if a traffic light system indicating areas of different radiation exposure improves non-radiological medical staff's radiation awareness and feeling of personal security. Phantom measurements were performed to define areas of different dose rates and colored stickers were applied on the floor according to a traffic light system: green = lowest, orange = intermediate, and red = highest possible radiation exposure. Non-radiological medical professionals with different years of working experience evaluated the system using a structured questionnaire. Kruskal-Wallis and Spearman's correlation test were applied for statistical analysis. Fifty-six subjects (30 physicians, 26 nursing staff) took part in this prospective study. Overall rating of the system was very good, and almost all professionals tried to stand in the green stickers during the scan. The system significantly increased radiation awareness and feeling of personal protection particularly in staff with ≤ 5 years of working experience (p < 0.05). The majority of non-radiological medical professionals stated that staying in the green stickers and patient care would be compatible. Knowledge of radiation protection was poor in all groups, especially among entry-level employees (p < 0.05). A traffic light system in the CT scanning room indicating areas with lowest, intermediate, and highest possible radiation exposure is much appreciated. It increases radiation awareness, improves the sense of personal radiation protection, and may support endeavors to lower occupational radiation exposure, although the best radiation protection always is to re-main outside the CT room during the scan. • A traffic light system indicating areas with different radiation exposure within the computed tomography scanner room is much appreciated by non-radiological medical staff. • The traffic light system increases non-radiological medical staff's radiation awareness and feeling of personal protection. • Knowledge on radiation protection was poor in non-radiological medical staff, especially in those with few working experience. © Georg Thieme Verlag KG Stuttgart · New York.
Diagnostic radiation exposure in pediatric trauma patients.
Brunetti, Marissa A; Mahesh, Mahadevappa; Nabaweesi, Rosemary; Locke, Paul; Ziegfeld, Susan; Brown, Robert
2011-02-01
The amount of imaging studies performed for disease diagnosis has been rapidly increasing. We examined the amount of radiation exposure that pediatric trauma patients receive because they are an at-risk population. Our hypothesis was that pediatric trauma patients are exposed to high levels of radiation during a single hospital visit. Retrospective review of children who presented to Johns Hopkins Pediatric Trauma Center from July 1, 2004, to June 30, 2005. Radiographic studies were recorded for each patient and doses were calculated to give a total effective dose of radiation. All radiographic studies that each child received during evaluation, including any associated hospital admission, were included. A total of 945 children were evaluated during the study year. A total of 719 children were included in the analysis. Mean age was 7.8 (±4.6) years. Four thousand six hundred three radiographic studies were performed; 1,457 were computed tomography (CT) studies (31.7%). Average radiation dose was 12.8 (±12) mSv. We found that while CT accounted for only 31.7% of the radiologic studies performed, it accounted for 91% of the total radiation dose. Mean dose for admitted children was 17.9 (±13.8) mSv. Mean dose for discharged children was 8.4 (±7.8) mSv (p<0.0001). Burn injuries had the lowest radiation dose [1.2 (±2.6) mSv], whereas motor vehicle collision victims had the highest dose [18.8 (±14.7) mSv]. When the use of radiologic imaging is considered essential, cumulative radiation exposure can be high. In young children with relatively long life spans, the benefit of each imaging study and the cumulative radiation dose should be weighed against the long-term risks of increased exposure.
The radiological exposure of man from radioactivity in the Baltic Sea.
Nielsen, S P; Bengtson, P; Bojanowsky, R; Hagel, P; Herrmann, J; Ilus, E; Jakobson, E; Motiejunas, S; Panteleev, Y; Skujina, A; Suplinska, M
1999-09-30
A radiological assessment has been carried out considering discharges of radioactivity to the Baltic Sea marine environment since 1950. The sources of radioactivity that have been evaluated are atmospheric nuclear-weapons fallout, fallout from the Chernobyl accident in 1986, discharges of radionuclides from Sellafield and La Hague transported into the Baltic Sea, and discharges of radionuclides from nuclear installations located in the Baltic Sea area. Dose rates from man-made radioactivity to individual members of the public (critical groups) have been calculated based on annual intake of seafood and beach occupancy time. The dose rates to individuals from the regions of the Bothnian Sea and Gulf of Finland are predicted to be larger than from any other area in the Baltic Sea due to the pattern of Chernobyl fallout. The dose rates are predicted to have peaked in 1986 at a value of 0.2 mSv year-1. Collective committed doses to members of the public have been calculated based on fishery statistics and predicted concentrations of radionuclides in biota and coastal sediments. The total collective dose from man-made radioactivity in the Baltic Sea is estimated at 2600 manSv, of which approximately two-thirds originate from Chernobyl fallout, approximately one-quarter from atmospheric nuclear-weapons fallout, approximately 8% from European reprocessing facilities, and approximately 0.04% from nuclear installations bordering the Baltic Sea area. An assessment of small-scale dumping of low-level radioactive waste in the Baltic Sea in the 1960s by Sweden and the Soviet Union has showed that doses to man from these activities are negligible. Dose rates and doses from natural radioactivity dominate except for the year 1986 where dose rates to individuals from Chernobyl fallout in some regions of the Baltic Sea approached those from natural radioactivity.
Vinnakota, Narayana R; Krishna, V; Viswanath, V; Ahmed, Zaheer; Shaik, Kamal S; Boppana, Naveen K
2016-12-01
To assess the knowledge, attitude, and practices of fixed dose combination drugs among postgraduate dental students. A cross-sectional study was carried out among postgraduate dental students of dental colleges in coastal Andhra Pradesh. Three colleges were randomly selected and students of all the three years were included. Data was collected from the specialities of oral medicine and radiology, oral surgery, endodontics, pedodontics, periodontics, and public health dentistry. The total sample was 90 postgraduate students; informed consent was obtained from the participants, and a pretested questionnaire was distributed to them. Data was analyzed using the Statistical Package for the Social Sciences version 20 software. Out of 90 postgraduates, 33 were males and 57 were females. Thirty-five percent were aware of the essential medical list (EML), among them 11% were from oral medicine and radiology and 6.7% were from pedodontics. However, most of them were unaware of the number of fixed dose combination drugs present in the World Health Organization EML. None of them were able to name at least a single banned fixed dose combination drug. Most of them were unaware of the advantages and disadvantages of using fixed dose combination drugs. Amoxicillin with clavulanic acid was the most common drug prescribed by students (73.3%) followed by ofloxacin with ornidazole (54.4%), ibuprofen with paracetamol (53.3%), and sulfamethoxazole with trimethoprim (6%). Most of them were unaware of the rationality in using fixed dose combination drugs. Common sources of information were medical representatives 43 (47.8%), internet 39 (43.3%), and 12 (13.3%) reported using WHO EML. There is an urgent need to improve knowledge on the rationality for using fixed dose combination, EML, and banned fixed dose combination in India to the promote rational use of fixed dose combination.
Kumar, Vinod; Goel, Rajeev; Chawla, Raman; Silambarasan, M.; Sharma, Rakesh Kumar
2010-01-01
Chemical, biological, radiological, and nuclear (CBRN) decontamination is the removal of CBRN material from equipment or humans. The objective of the decontamination is to reduce radiation burden, salvage equipment, and materials, remove loose CBRN contaminants, and fix the remaining in place in preparation for protective storage or permanent disposal work activities. Decontamination may be carried out using chemical, electrochemical, and mechanical means. Like materials, humans may also be contaminated with CBRN contamination. Changes in cellular function can occur at lower radiation doses and exposure to chemicals. At high dose, cell death may take place. Therefore, decontamination of humans at the time of emergency while generating bare minimum waste is an enormous task requiring dedication of large number of personnel and large amount of time. General principles of CBRN decontamination are discussed in this review with emphasis on radiodecontamination. PMID:21829318
Radiation Protection in Pediatric Radiology: Results of a Survey Among Dutch Hospitals.
Bijwaard, Harmen; Valk, Doreth; de Waard-Schalkx, Ischa
2016-10-01
A survey about radiation protection in pediatric radiology was conducted among 22 general and seven children's hospitals in the Netherlands. Questions concerned, for example, child protocols used for CT, fluoroscopy and x-ray imaging, number of images and scans made, radiation doses and measures taken to reduce these, special tools used for children, and quality assurance issues. The answers received from 27 hospitals indicate that radiation protection practices differ considerably between general and children's hospitals but also between the respective general and children's hospitals. It is recommended that hospitals consult each other to come up with more uniform best practices. Few hospitals were able to supply doses that can be compared to the national Diagnostic Reference Levels (DRLs). The ones that could be compared exceeded the DRLs in one in five cases, which is more than was expected beforehand.
[Wireless digital radiography detectors in the emergency area: an efficacious solution].
Garrido Blázquez, M; Agulla Otero, M; Rodríguez Recio, F J; Torres Cabrera, R; Hernando González, I
2013-01-01
To evaluate the implementation of a flat panel digital radiolography (DR) system with WiFi technology in an emergency radiology area in which a computed radiography (CR) system was previously used. We analyzed aspects related to image quality, radiation dose, workflow, and ergonomics. We analyzed the results obtained with the CR and WiFi DR systems related with the quality of images analyzed in images obtained using a phantom and after radiologists' evaluation of radiological images obtained in real patients. We also analyzed the time required for image acquisition and the workflow with the two technological systems. Finally, we analyzed the data related to the dose of radiation in patients before and after the implementation of the new equipment. Image quality improved in both the tests carried out with a phantom and in radiological images obtained in patients, which increased from 3 to 4.5 on a 5-point scale. The average time required for image acquisition decreased by 25 seconds per image. The flat panel required less radiation to be delivered in practically all the techniques carried out using automatic dosimetry, although statistically significant differences were found in only some of the techniques (chest, thoracic spine, and lumbar spine). Implementing the WiFi DR system has brought benefits. Image quality has improved and the dose of radiation to patients has decreased. The new system also has advantages in terms of functionality, ergonomics, and performance. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
SU-F-I-06: Evaluation of Imaging Dose for Modulation Layer Based Dual Energy Cone-Beam CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ju, Eunbin; Ahn, SoHyun; Cho, Samju
Purpose: Dual energy cone beam CT system is finding a variety of promising applications in diagnostic CT, both in imaging of endogenous materials and exogenous materials across a range of body sites. Dual energy cone beam CT system to suggest in this study acquire image by rotating 360 degree with half of the X-ray window covered using copper modulation layer. In the region that covered by modulation layer absorb the low energy X-ray by modulation layer. Relative high energy X-ray passes through the layer and contributes to image reconstruction. Dose evaluation should be carried out in order to utilize suchmore » an imaging acquirement technology for clinical use. Methods: For evaluating imaging dose of modulation layer based dual energy cone beam CT system, Prototype cone beam CT that configured X-ray tube (D054SB, Toshiba, Japan) and detector (PaxScan 2520V, Varian Medical Systems, Palo Alto, CA) is used. A range of 0.5–2.0 mm thickness of modulation layer is implemented in Monte Carlo simulation (MCNPX, ver. 2.6.0, Los Alamos National Laboratory, USA) with half of X-ray window covered. In-house phantom using in this study that has 3 cylindrical phantoms configured water, Teflon air with PMMA covered for verifying the comparability the various material in human body and is implemented in Monte Carlo simulation. The actual dose with 2.0 mm copper covered half of X-ray window is measured using Gafchromic EBT3 film with 5.0 mm bolus for compared with simulative dose. Results: Dose in phantom reduced 33% by copper modulation layer of 2.0 mm. Scattering dose occurred in modulation layer by Compton scattering effect is 0.04% of overall dose. Conclusion: Modulation layer of that based dual energy cone beam CT has not influence on unnecessary scatter dose. This study was supported by the Radiation Safety Research Programs (1305033) through the Nuclear Safety and Security Commission.« less
Ionizing radiation-induced acoustics for radiotherapy and diagnostic radiology applications.
Hickling, Susannah; Xiang, Liangzhong; Jones, Kevin C; Parodi, Katia; Assmann, Walter; Avery, Stephen; Hobson, Maritza; El Naqa, Issam
2018-04-21
Acoustic waves are induced via the thermoacoustic effect in objects exposed to a pulsed beam of ionizing radiation. This phenomenon has interesting potential applications in both radiotherapy dosimetry and treatment guidance as well as low dose radiological imaging. After initial work in the field in the 1980s and early 1990s, little research was done until 2013 when interest was rejuvenated, spurred on by technological advances in ultrasound transducers and the increasing complexity of radiotherapy delivery systems. Since then, many studies have been conducted and published applying ionizing radiation-induced acoustic principles into three primary research areas: Linear accelerator photon beam dosimetry, proton therapy range verification, and radiological imaging. This review article introduces the theoretical background behind ionizing radiation-induced acoustic waves, summarizes recent advances in the field, and provides an outlook on how the detection of ionizing radiation-induced acoustic waves can be used for relative and in vivo dosimetry in photon therapy, localization of the Bragg peak in proton therapy, and as a low-dose medical imaging modality. Future prospects and challenges for clinical implementation of these techniques are discussed. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
NASA Astrophysics Data System (ADS)
Ibrahim, Ziadoon H.; Ibrahim, S. A.; Mohammed, M. K.; Shaban, A. H.
2018-05-01
The purpose of this study is to evaluate the radiological risks for workers for one year of their activities at Fuel Fabrication Facility (FFF) so as to make the necessary protection to prevent or minimize risks resulted from these activities this site now is under the Iraqi decommissioning program (40). Soil samples surface and subsurface were collected from different positions of this facility and analyzed by gamma rays spectroscopy technique High Purity Germanium detector (HPGe) was used. It was found out admixture of radioactive isotopes (232Th 40K 238U 235U137Cs) according to the laboratory results the highest values were (975758) for 238U (21203) for 235U (218) for 232Th (4046) for 40K and (129) for 137Cs in (Bqkg1) unit. The annual total radiation dose and risks were estimated by using RESRAD (onsite) 70 computer code. The highest total radiation dose was (5617μSv/year) in area that represented by soil sample (S7) and the radiological risks morbidity and mortality (118E02 8661E03) respectively in the same area
Hussain, Fahad Ahmed; Mail, Noor; Shamy, Abdulrahman M; Suliman, Alghamdi; Saoudi, Abdelhamid
2016-05-08
Image quality is a key issue in radiology, particularly in a clinical setting where it is important to achieve accurate diagnoses while minimizing radiation dose. Some computed tomography (CT) manufacturers have introduced algorithms that claim significant dose reduction. In this study, we assessed CT image quality produced by two reconstruction algorithms provided with GE Healthcare's Discovery 690 Elite positron emission tomography (PET) CT scanner. Image quality was measured for images obtained at various doses with both conventional filtered back-projection (FBP) and adaptive statistical iterative reconstruction (ASIR) algorithms. A stan-dard CT dose index (CTDI) phantom and a pencil ionization chamber were used to measure the CT dose at 120 kVp and an exposure of 260 mAs. Image quality was assessed using two phantoms. CT images of both phantoms were acquired at tube voltage (kV) of 120 with exposures ranging from 25 mAs to 400 mAs. Images were reconstructed using FBP and ASIR ranging from 10% to 100%, then analyzed for noise, low-contrast detectability, contrast-to-noise ratio (CNR), and modulation transfer function (MTF). Noise was 4.6 HU in water phantom images acquired at 260 mAs/FBP 120 kV and 130 mAs/50% ASIR 120 kV. The large objects (fre-quency < 7 lp/cm) retained fairly acceptable image quality at 130 mAs/50% ASIR, compared to 260 mAs/FBP. The application of ASIR for small objects (frequency >7 lp/cm) showed poor visibility compared to FBP at 260 mAs and even worse for images acquired at less than 130 mAs. ASIR blending more than 50% at low dose tends to reduce contrast of small objects (frequency >7 lp/cm). We concluded that dose reduction and ASIR should be applied with close attention if the objects to be detected or diagnosed are small (frequency > 7 lp/cm). Further investigations are required to correlate the small objects (frequency > 7 lp/cm) to patient anatomy and clinical diagnosis.
Hilmes, Melissa A; Hyatt, Eddie; Penrod, Cody H; Fleming, Amy E; Singh, Sudha P
2016-03-01
Traditionally, the pediatric radiology elective for medical students and pediatric residents constituted a morning teaching session focused mainly on radiography and fluoroscopy. A more structured elective was desired to broaden the exposure to more imaging modalities, create a more uniform educational experience, and include assessment tools. In 2012, an introductory e-mail and formal syllabus, including required reading assignments, were sent to participants before the start date. A rotating weekly schedule was expanded to include cross-sectional imaging (ultrasound, CT, MR) and nuclear medicine. The schedule could accommodate specific goals of the pediatric resident or medical student, as requested. Starting in 2013, an online pre-test and post-test were developed, as well as an online end-of-rotation survey specific to the pediatric radiology elective. Taking the Image Gently pledge was required. A scavenger hunt tool, cue cards, and electronic modules were added. Pre-test and post-test scores, averaged over 2 years, showed improvement in radiology knowledge, with scores increasing by 27% for medical students and 21% for pediatric residents. Surveys at the end of the elective were overwhelmingly positive, with constructive criticism and complimentary comments. We have successfully created an elective experience in radiology that dedicates time to education while preserving the workflow of radiologists. We have developed tools to provide a customized experience with many self-directed learning opportunities. Our tools and techniques are easily translatable to a general or adult radiology elective. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Dodd, Gerald D
2011-08-01
There has been a substantial proliferation in the number of radiology organizations over the past 30 years. This has occurred without integrated planning or the development of a central administration. Although each of the 50-plus organizations was created for specific reasons, the lack of coordination among them has led to considerable duplication of missions, services, and resources. The majority of the members attending the 2010 meeting of the Intersociety Conference believe that radiology as a whole would benefit from collaboration and consolidation of our organizations. Specific opportunities for collaboration include joint annual meetings between 2 or more organizations, the creation of a clearinghouse for meeting scheduling that would minimize meeting conflicts, coordinated development of self-assessment modules, the development of an online site for "one-stop shopping" for paying dues and making foundation contributions, consolidation of the 15-plus radiology foundations to increase the investment corpus and allow larger targeted investments in specific research projects that would benefit radiology as a whole, and the creation of a new Web site that would link all radiology organizations to facilitate information access and collaboration. To move forward with meaningful and successful collaboration or consolidation will require an accurate database of the mission, structure, and function of our organizations; a careful analysis of potential synergies; and, full buy-in by the participating organizations. Copyright © 2011 American College of Radiology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Angel, Erin; Yaghmai, Nazanin; Matilda Jude, Cecilia; DeMarco, John J.; Cagnon, Christopher H.; Goldin, Jonathan G.; Primak, Andrew N.; Stevens, Donna M.; Cody, Dianna D.; McCollough, Cynthia H.; McNitt-Gray, Michael F.
2009-02-01
Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patient's glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patient's clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were size dependent with smaller patients getting better dose reduction (up to 64% reduction) and larger patients getting a smaller reduction, and in some cases the dose actually increased when using tube current modulation (up to 41% increase). The results indicate that radiation dose to glandular breast tissue generally decreases with the use of tube current modulated CT acquisition, but that patient size (and in some cases patient positioning) may affect dose reduction.
Review of Radioisotopes as Radiological Weapons
2016-06-01
doses of radiation . Two of the woodsmen devel- oped serious symptoms of Acute Radiation Syndrome (ARS) and beta radiation burns that required...or organs). Absorbed dose is usually defined as energy deposited (joule) per unit of mass (kilogram). See gray and rad. Acute Radiation Syndrome ...AI alveolar-interstitial ALARA as low as reasonably achievable ARS Acute Radiation Syndrome Bq becquerel C Activity of Concern CDC Centers for
Priya, S; Srinivasan, P; Gopalakrishnan, R K
2012-01-01
The thoria dissolver, used for separation of (233)U from reactor-irradiated thorium metal and thorium oxide rods, is no longer operational. It was decided to carry out assessment of the radiological status of the dissolver cell for planning of the future decommissioning/dismantling operations. The dissolver interiors are expected to be contaminated with the dissolution remains of irradiated thorium oxide rods in addition to some of the partially dissolved thoria pellets. Hence, (220)Rn, a daughter product of (228)Th is of major radiological concern. Airborne activity of thoron daughters (212)Pb (Th-B) and (212)Bi (Th-C) was estimated by air sampling followed by high-resolution gamma spectrometry of filter papers. By measuring the full-energy peaks counts in the energy windows of (212)Pb, (212)Bi and (208)Tl, concentrations of thoron progeny in the sampled air were estimated by applying the respective intrinsic peak efficiency factors and suitable correction factors for the equilibration effects of (212)Pb and (212)Bi in the filter paper during the delay between sampling and counting. Then the thoron working level (TWL) was evaluated using the International Commission on Radiological Protection (ICRP) methodology. Finally, the potential effective dose to the workers, due to inhalation of thoron and its progeny during dismantling operations was assessed by using dose conversion factors recommended by ICRP. Analysis of filter papers showed a maximum airborne thoron progeny concentration of 30 TWLs inside the dissolver.
Internal thyroid doses to Fukushima residents-estimation and issues remaining.
Kim, Eunjoo; Kurihara, Osamu; Kunishima, Naoaki; Momose, Takumaro; Ishikawa, Tetsuo; Akashi, Makoto
2016-08-01
Enormous quantities of radionuclides were released into the environment following the disastrous accident at the Fukushima Daiichi Nuclear Power Plant (FDNPP) in March 2011. It is of great importance to determine the exposure doses received by the populations living in the radiologically affected areas; however, there has been significant difficulty in estimating the internal thyroid dose received through the intake of short-lived radionuclides (mainly, (131)I), because of the lack of early measurements on people. An estimation by the National Institute of Radiological Sciences for 1 April 2012 to 31 March 2013 was thus performed using a combination of the following three sources: thyroid measurement data ((131)I) for 1080 children examined in the screening campaign, whole-body counter measurement data ((134)Cs, (137)Cs) for 3000 adults, and atmospheric transport dispersion model simulations. In this study, the residents of Futaba town, Iitate village and Iwaki city were shown to have the highest thyroid equivalent dose, and their doses were estimated to be mostly below 30 mSv. However, this result involved a lot of uncertainties and provided only representative values for the residents. The present paper outlines a more recent dose estimation and preliminary analyses of personal behavior data used in the new method. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
TL dosimetry for quality control of CR mammography imaging systems
NASA Astrophysics Data System (ADS)
Gaona, E.; Nieto, J. A.; Góngora, J. A. I. D.; Arreola, M.; Enríquez, J. G. F.
The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full field digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalideE We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.
Miller, Susan M; Ferrarotto, Catherine L; Vlahovich, Slavica; Wilkins, Ruth C; Boreham, Douglas R; Dolling, Jo-Anna
2007-07-01
To test the ability of the cytogenetic emergency network (CEN) of laboratories, currently under development across Canada, to provide rapid biological dosimetry using the dicentric assay for triage assessment, that could be implemented in the event of a large-scale radiation/nuclear emergency. A workshop was held in May 2004 in Toronto, Canada, to introduce the concept of CEN and recruit clinical cytogenetic laboratories at hospitals across the country. Slides were prepared for dicentric assay analysis following in vitro irradiation of blood to a range of gamma-ray doses. A minimum of 50 metaphases per slide were analyzed by 41 people at 22 different laboratories to estimate the exposure level. Dose estimates were calculated based on a dose response curve generated at Health Canada. There were a total of 104 dose estimates and 96 (92.3%) of them fell within the expected range using triage scoring criteria. Half of the laboratories analyzed 50 metaphases in = 1 hour and the time to score them was proportional to dose. The capacity and scoring expertise of the various participating laboratories were found to be generally acceptable. The dose estimates generated through triage scoring by this network were acceptable for emergency biological dosimetry. When this network is fully operational, it will be the first of its kind in Canada able to respond to radiological/nuclear emergencies by providing triage quality biological dosimetry for a large number of samples. This network represents an alternate expansion of existing international emergency biological dosimetry cytogenetic networks.
Assessment of natural radionuclides and its radiological hazards from tiles made in Nigeria
NASA Astrophysics Data System (ADS)
Joel, E. S.; Maxwell, O.; Adewoyin, O. O.; Ehi-Eromosele, C. O.; Embong, Z.; Saeed, M. A.
2018-03-01
Activity concentration of 10 different brands of tiles made in Nigeria were analyzed using High purity Germanium gamma detector and its hazard indices such as absorbed dose rate, radium equivalent activity, external Hazard Index (Hex), internal Hazard Index (Hin), Annual Effective Dose (mSv/y), Gamma activity Index (Iγ) and Alpha Index (Iα) were determined. The result showed that the average activity concentrations of radionuclides (226Ra, 232Th and 40K) content are within the recommended limit. The average radium equivalent is within the recommended limit of 370 Bq/kg. The result obtained further showed that the mean values for the absorbed dose rate (D), external and internal hazard index, the annual effective dose (AEDR) equivalent, gamma activity index and Alpha Index were: 169.22 nGyh-1, 0.95 and 1.14, 1.59 mSv/y, 1.00 Sv yr-1 and 0.34 respectively. The result established that radiological hazards such as absorbed dose rate, internal hazard, annual effective dose rate, gamma activity index and Alpha Index for some samples are found to be slightly close or above international recommended values. The result for the present study was compared with tiles sample from others countries, it was observed that the concentration of tiles made in Nigeria and other countries are closer, however recommends proper radiation monitoring for some tiles made in Nigeria before usage due to the long term health effect.
Sahin, Latife; Hafızoğlu, Nurgül; Çetinkaya, Hakan; Manisa, Kaan; Bozkurt, Engin; Biçer, Ahmet
2017-05-01
The analysis of natural radioactivity from 238 U, 232 Th and 40 K in 357 soil samples collected from the province of Kütahya was carried out using a NaI(Tl) gamma-ray spectroscopy system at the Nuclear Physics Research Laboratory, Dumlupınar University, Kütahya, Turkey. The specific activities of 238 U, 232 Th and 40 K in the soil samples were evaluated. From the activity concentrations of 238 U, 232 Th and 40 K, the total absorbed outdoor gamma-ray dose rates and the corresponding annual effective dose rates were determined. The corresponding values of the external and internal hazard indices of all the soil samples were also calculated. The external gamma-ray dose rate at 1 m above the ground was directly measured at each collected soil sample location. The results obtained in this study were compared within the limits of values obtained in other cities of Turkey, those in other countries. Radiological maps of Kütahya Province were constructed from the results of this study.
Canbaz, Buket; Cam, N Füsun; Yaprak, Günseli; Candan, Osman
2010-09-01
The surveys of natural gamma-emitting radionuclides in rocks and soils from the Ezine plutonic area were conducted during 2007. Direct dose measurement using a survey meter was carried out simultaneously. The present study, which is part of the survey, analysed the activity concentrations of (238)U, (232)Th and (40)K in granitoid samples from all over the region by HPGe gamma spectrometry. The activity concentrations of (226)Ra ranged from 94 to 637 Bq kg(-1), those of (232)Th ranged from 120 to 601 Bq kg(-1)and those of (40)K ranged from 1074 to 1527 Bq kg(-1) in the analysed rock samples from different parts of the pluton. To evaluate the radiological hazard of the natural radioactivity in the samples, the absorbed dose rate (D), the annual effective dose rate, the radium equivalent activity (Ra(eq)) and the external (H(ex)) hazard index were calculated according to the UNSCEAR 2000 report. The thorium-to-uranium concentration ratios were also estimated.
Recommendations to harmonize European early warning dosimetry network systems
NASA Astrophysics Data System (ADS)
Dombrowski, H.; Bleher, M.; De Cort, M.; Dabrowski, R.; Neumaier, S.; Stöhlker, U.
2017-12-01
After the Chernobyl nuclear power plant accident in 1986, followed by the Fukushima Nuclear power plant accident 25 years later, it became obvious that real-time information is required to quickly gain radiological information. As a consequence, the European countries established early warning network systems with the aim to provide an immediate warning in case of a major radiological emergency, to supply reliable information on area dose rates, contamination levels, radioactivity concentrations in air and finally to assess public exposure. This is relevant for governmental decisions on intervention measures in an emergency situation. Since different methods are used by national environmental monitoring systems to measure area dose rate values and activity concentrations, there are significant differences in the results provided by different countries. Because European and neighboring countries report area dose rate data to a central data base operated on behalf of the European Commission, the comparability of the data is crucial for its meaningful interpretation, especially in the case of a nuclear accident with transboundary implications. Only by harmonizing measuring methods and data evaluation, is the comparability of the dose rate data ensured. This publication concentrates on technical requirements and methods with the goal to effectively harmonize area dose rate monitoring data provided by automatic early warning network systems. The requirements and procedures laid down in this publication are based on studies within the MetroERM project, taking into account realistic technical approaches and tested procedures.
Giri, Soma; Jha, V N; Singh, Gurdeep; Tripathi, R M
2012-07-01
To study the distribution of (210)Po activity in food in Bagjata in East Singhbhum, India. (210)Po were analyzed in the food samples of plant origin such as cereals, pulses, fruits, vegetables and food of animal origin such fish, chicken, egg, etc., in and around Bagjata uranium mining area as a part of baseline study after acid digestion. The intake and ingestion dose of the radionuclide was estimated. The general range of (210)Po activity in all the dietary components ranged widely from <0.2-36 Bqkg(-1)(fresh). In the food of plant origin, the minimum activity of (210)Po was estimated in vegetables while maximum in pulses. In food of animal origin, the observed minimum activity of (210)Po was in eggs and the maximum observed was in chicken samples. The intake of (210)Po considering all dietary components was found to be 464 Bq.Y(-1) while the ingestion dose was calculated to be 557 μSv.Y(-1), respectively. The estimated doses are reflecting the natural background dose via the route of ingestion, which is much below the 1 mSv limit set in the International Commission on Radiological Protection (ICRP) recommendations. The study confirms that current levels of (210)Po do not pose a significant radiological risk to the local inhabitants.
Bernardo, Mônica Oliveira; Almeida, Fernando Antonio de; Morgado, Flavio
2017-01-01
To analyze the results of an initiative aimed at improving the reasonable use of radiological examinations, ensuring their technical quality, implementing a radioprotection campaign that includes training of the professional team, and introducing the radioprotection card for children under 12 years old as a tool for parents and doctors to control children's exposure to radiation. The study was held in a health care insurance system covering 140,000 people. A radioprotection campaign was implemented according to Image Gently • protocols, ensuring the lowest dose of radiation and the quality of examinations, and the radioprotection card was implemented. To assess the effectiveness of these actions, the number of radiological examinations performed at the pediatric emergency room in a period of one year preceding the campaign was compared with the number of radiological examinations performed one year after the campaign. The campaign was well accepted by all professionals, families, and patients involved. In the year following the implementation of radioprotection strategies, there was a 22% reduction of radiological examinations performed at the pediatric emergency room. There was also a 29% reduction in the request of two or more radiological examinations for the same child or examinations with two or more incidences. The campaign and the radioprotection card for children under 12 years old proved to be feasible strategies and correlated with a reduction in radiological examinations requested and performed at the pediatric emergency room.
The Radiological Physics Center's standard dataset for small field size output factors.
Followill, David S; Kry, Stephen F; Qin, Lihong; Lowenstein, Jessica; Molineu, Andrea; Alvarez, Paola; Aguirre, Jose Francisco; Ibbott, Geoffrey S
2012-08-08
Delivery of accurate intensity-modulated radiation therapy (IMRT) or stereotactic radiotherapy depends on a multitude of steps in the treatment delivery process. These steps range from imaging of the patient to dose calculation to machine delivery of the treatment plan. Within the treatment planning system's (TPS) dose calculation algorithm, various unique small field dosimetry parameters are essential, such as multileaf collimator modeling and field size dependence of the output. One of the largest challenges in this process is determining accurate small field size output factors. The Radiological Physics Center (RPC), as part of its mission to ensure that institutions deliver comparable and consistent radiation doses to their patients, conducts on-site dosimetry review visits to institutions. As a part of the on-site audit, the RPC measures the small field size output factors as might be used in IMRT treatments, and compares the resulting field size dependent output factors to values calculated by the institution's treatment planning system (TPS). The RPC has gathered multiple small field size output factor datasets for X-ray energies ranging from 6 to 18 MV from Varian, Siemens and Elekta linear accelerators. These datasets were measured at 10 cm depth and ranged from 10 × 10 cm(2) to 2 × 2 cm(2). The field sizes were defined by the MLC and for the Varian machines the secondary jaws were maintained at a 10 × 10 cm(2). The RPC measurements were made with a micro-ion chamber whose volume was small enough to gather a full ionization reading even for the 2 × 2 cm(2) field size. The RPC-measured output factors are tabulated and are reproducible with standard deviations (SD) ranging from 0.1% to 1.5%, while the institutions' calculated values had a much larger SD range, ranging up to 7.9% [corrected].The absolute average percent differences were greater for the 2 × 2 cm(2) than for the other field sizes. The RPC's measured small field output factors provide institutions with a standard dataset against which to compare their TPS calculated values. Any discrepancies noted between the standard dataset and calculated values should be investigated with careful measurements and with attention to the specific beam model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zelefsky, Michael J., E-mail: zelefskm@mskcc.org; Greco, Carlo; Motzer, Robert
2012-04-01
Purpose: To report tumor local progression-free outcomes after treatment with single-dose, image-guided, intensity-modulated radiotherapy and hypofractionated regimens for extracranial metastases from renal cell primary tumors. Patients and Methods: Between 2004 and 2010, 105 lesions from renal cell carcinoma were treated with either single-dose, image-guided, intensity-modulated radiotherapy to a prescription dose of 18-24 Gy (median, 24) or hypofractionation (three or five fractions) with a prescription dose of 20-30 Gy. The median follow-up was 12 months (range, 1-48). Results: The overall 3-year actuarial local progression-free survival for all lesions was 44%. The 3-year local progression-free survival for those who received a highmore » single-dose (24 Gy; n = 45), a low single-dose (<24 Gy; n = 14), or hypofractionation regimens (n = 46) was 88%, 21%, and 17%, respectively (high single dose vs. low single dose, p = .001; high single dose vs. hypofractionation, p < .001). Multivariate analysis revealed the following variables were significant predictors of improved local progression-free survival: 24 Gy dose compared with a lower dose (p = .009) and a single dose vs. hypofractionation (p = .008). Conclusion: High single-dose, image-guided, intensity-modulated radiotherapy is a noninvasive procedure resulting in high probability of local tumor control for metastatic renal cell cancer generally considered radioresistant according to the classic radiobiologic ranking.« less
Energy spectrum control for modulated proton beams.
Hsi, Wen C; Moyers, Michael F; Nichiporov, Dmitri; Anferov, Vladimir; Wolanski, Mark; Allgower, Chris E; Farr, Jonathan B; Mascia, Anthony E; Schreuder, Andries N
2009-06-01
In proton therapy delivered with range modulated beams, the energy spectrum of protons entering the delivery nozzle can affect the dose uniformity within the target region and the dose gradient around its periphery. For a cyclotron with a fixed extraction energy, a rangeshifter is used to change the energy but this produces increasing energy spreads for decreasing energies. This study investigated the magnitude of the effects of different energy spreads on dose uniformity and distal edge dose gradient and determined the limits for controlling the incident spectrum. A multilayer Faraday cup (MLFC) was calibrated against depth dose curves measured in water for nonmodulated beams with various incident spectra. Depth dose curves were measured in a water phantom and in a multilayer ionization chamber detector for modulated beams using different incident energy spreads. Some nozzle entrance energy spectra can produce unacceptable dose nonuniformities of up to +/-21% over the modulated region. For modulated beams and small beam ranges, the width of the distal penumbra can vary by a factor of 2.5. When the energy spread was controlled within the defined limits, the dose nonuniformity was less than +/-3%. To facilitate understanding of the results, the data were compared to the measured and Monte Carlo calculated data from a variable extraction energy synchrotron which has a narrow spectrum for all energies. Dose uniformity is only maintained within prescription limits when the energy spread is controlled. At low energies, a large spread can be beneficial for extending the energy range at which a single range modulator device can be used. An MLFC can be used as part of a feedback to provide specified energy spreads for different energies.
Radwan, Ahmed Bassiuony; El-Debeiky, Mohammed Soliman; Abdel-Hay, Sameh
2015-08-01
Overflow retentive stool incontinence (ORSI) is secondary to constipation and fecal loading. In our study, the dose and duration of senna-based laxatives (SBL) treatment to achieve full defecatory control will be examined for possible correlation with new parameters measured from the initial contrast enema. Initially, an observational study was conducted prospectively on a group of patient with ORSI to define the optimum dose of SBL to achieve full defecatory control with measurement of six parameters in the initial contrast enema (level of colonic dilatation, recto-anal angle, ratio of maximal diameter of dilated colon to last lumbar spine, ratio of maximum diameter of dilated colon to normal descending colon, immediate and after 24-h post-evacuation residual contrast). The result was analyzed statistically to reach a correlation between the radiological data and prescribed dose. Over 2 and half years, 72 patients were included in the study; their mean age was 6.3 ± 3.33 years. The mean effective starting dose of SBL was 57 ± 18.13 mg/day and the mean effective ending dose was 75 ± 31.68 mg/day. Time lapsed till full defecatory control ranged from 1 to 16 weeks. Statistical correlation revealed that mean effective ending dose of SBL treatment significantly increased with higher levels of colonic dilatation. A weak positive correlation was found for both the mean effective starting and ending doses with the ratio of maximum colonic diameter to last lumbar spine and descending colonic diameters ratio. Senna-based laxatives are effective treatment for overflow retentive stool incontinence and their doses can be adjusted initially depending on the analysis of the radiological data.
Bohl, Michael A; Goswami, Roopa; Strassner, Brett; Stanger, Paula
2016-08-01
The purpose of this investigation was to evaluate the potential of using the ACR's Dose Index Registry(®) to meet The Joint Commission's requirements to identify incidents in which the radiation dose index from diagnostic CT examinations exceeded the protocol's expected dose index range. In total, 10,970 records in the Dose Index Registry were statistically analyzed to establish both an upper and lower expected dose index for each protocol. All 2015 studies to date were then retrospectively reviewed to identify examinations whose total examination dose index exceeded the protocol's defined upper threshold. Each dose incident was then logged and reviewed per the new Joint Commission requirements. Facilities may leverage their participation in the ACR's Dose Index Registry to fully meet The Joint Commission's dose incident identification review and external benchmarking requirements. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
1998-01-01
(79) Waste, by definition, has no benefit. It should be viewed as one aspect of the beneficial practice that gave rise to it. Furthermore, radioactive waste management should be placed in the context of the management of society's waste in general. (80) A major issue in evaluating the acceptability of a disposal system for long-lived solid radioactive waste is that doses or risks may arise from exposures in the distant future. There is uncertainty surrounding any estimate of these doses or risks due to lack of knowledge about future conditions. Such exposures are treated as potential exposures as their magnitude depends on future processes and conditions that have probabilities associated with them. (81) Nevertheless, the Commission recognises a basic principle that individuals and populations in the future should be afforded at least the same level of protection from the action of disposing of radioactive waste today as is the current generation. This implies use of the current quantitative dose and risk criteria derived from considering associated health detriment. Therefore, protection of future generations should be achieved by applying these dose or risk criteria to the estimated future doses or risks in appropriately defined critical groups. These estimates should not be regarded as measures of health detriment beyond times of around several hundreds of years into the future. In the case of these longer time periods, they represent indicators of the protection afforded by the disposal system. (82 Constrained optimisation is the central approach to evaluating the radiological acceptability of a waste disposal system; dose or risk constraints are used rather than dose or risk limits. By this transition from limitation to optimisation, the needs of practical application of the radiological protection system to the disposal of long-lived solid waste disposal are met: determination of acceptability now for exposures that may occur in the distant future. Optimisation should be applied in an iterative manner during the disposal system development process and should particularly cover both site selection and repository design. (83) Two broad categories of exposure situations should be considered: natural processes and human intrusion. The latter only refers to intrusion that is inadvertent. The radiological implications of deliberate intrusion into a repository are the responsibility of the intruder. Assessed doses or risks arising from natural processes should be compared with a dose constraint of 0.3 mSv per year or its risk equivalent of around 10(-5) per year. With regard to human intrusion, the consequences from one or more plausible stylized scenarios should be considered in order to evaluate the resilience of the repository to such events. (84) The Commission considers that in circumstances where human intrusion could lead to doses to those living around the site sufficiently high that intervention on current criteria would almost always be justified, reasonable efforts should be made at the repository development stage to reduce the probability of human intrusion or to limit its consequences. In this respect, the Commission has previously advised that an existing annual dose of around 10 mSv per year may be used as a generic reference level below which intervention is not likely to be justifiable. Conversely, an existing annual dose of around 100 mSv per year may be used as a generic reference level above which intervention should be considered almost always justifiable. Similar considerations apply in situations where the thresholds for deterministic effects in relevant organs are exceeded. (85) Compliance with the constraints can be assessed by utilising either an aggregated risk-oriented approach, with a risk constraint, or a disaggregated dose/probability approach, with a dose constraint, or a combination of both. A similar level of protection can be achieved by any of these approaches; however, more information may
SU-G-IeP3-13: Real-Time Patient and Staff Dose Monitoring in Fluoroscopy Guided Interventions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vergoossen, L; Sailer, A; Paulis, L
Purpose: Interventional radiology procedures involve the use of X-rays, which can pose a large radiation burden on both patients and staff. Although some reports on radiation dose are available, most studies focus on limited types of procedures and only report patient dose. In our cathlabs a dedicated real-time patient and staff monitoring system was installed in November 2015. The aim of this study was to investigate the patient and staff dose exposure for different types of interventions. Methods: Radiologists involved in fluoroscopy guided interventional radiology procedures wore personal dose meters (PDM, DoseAware, Philips) on their lead-apron that measured the personalmore » dose equivalent Hp(10), a measure for the effective dose (E). Furthermore, reference PDMs were installed in the C-arms of the fluoroscopy system (Allura XPer, Philips). Patient dose-area-product (DAP) and PDM doses were retrieved from the monitoring system (DoseWise, Philips) for each procedure. A total of 399 procedures performed between November 2015 and February 2016 were analyzed with respect to the type of intervention. Interventions were grouped by anatomy and radiologist position. Results: The mean DAP for the different types of interventions ranged from 2.86±2.96 Gycm{sup 2} (percutaneous gastrostomy) to 147±178 Gycm{sup 2} (aortic repair procedures). The radiologist dose (E) ranged from 5.39±7.38 µSv (cerebral interventions) to 84.7±106 µSv (abdominal interventions) and strongly correlated with DAP (R{sup 2}=0.83). The E normalized to DAP showed that the relative radiologist dose was higher for interventions in larger body parts (e.g. abdomen) compared to smaller body parts (e.g. head). Conclusion: Using a real-time dose monitoring system we were able to assess the staff and patient dose revealing that the relative staff dose strongly depended on the type of procedure and patient anatomy. This could be explained by the position of the radiologist with respect to the patient and X-ray tube. To facilitate this study L Vergoossen received a scholarship from Philips Medical Systems.« less
Total Ionizing Dose Test Report for the UC1823A Pulse Width Modulator
NASA Technical Reports Server (NTRS)
Chen, Dakai; Forney, James
2017-01-01
The purpose of this study is to examine the total ionizing dose susceptibility for the UC1823A pulse width modulator manufactured by Texas Instruments, Inc. The part is suspected to be vulnerable to enhanced low dose rate sensitivity (ELDRS).
An active pixel sensor to detect diffused X-ray during Interventional Radiology procedure
NASA Astrophysics Data System (ADS)
Servoli, L.; Battisti, D.; Biasini, M.; Checcucci, B.; Conti, E.; Di Lorenzo, R.; Esposito, A.; Fanò, L.; Paolucci, M.; Passeri, D.; Pentiricci, A.; Placidi, P.
2012-04-01
Interventional radiologists and staff members are frequently exposed to protracted and fractionated low doses of ionizing radiation due to diffused X-ray radiation. The authors propose a novel approach to monitor on line staff during their interventions by using a device based on an Active Pixel Sensor developed for tracking applications. Two different photodiode configurations have been tested in standard Interventional Radiology working conditions. Both options have demonstrated the capability to measure the photon flux and the energy flux to a sufficient degree of uncertainty.
NASA Astrophysics Data System (ADS)
Srinivasan, P.; Priya, S.; Patel, Tarun; Gopalakrishnan, R. K.; Sharma, D. N.
2015-01-01
DD/DT fusion neutron generators are used as sources of 2.5 MeV/14.1 MeV neutrons in experimental laboratories for various applications. Detailed knowledge of the radiation dose rates around the neutron generators are essential for ensuring radiological protection of the personnel involved with the operation. This work describes the experimental and Monte Carlo studies carried out in the Purnima Neutron Generator facility of the Bhabha Atomic Research Center (BARC), Mumbai. Verification and validation of the shielding adequacy was carried out by measuring the neutron and gamma dose-rates at various locations inside and outside the neutron generator hall during different operational conditions both for 2.5-MeV and 14.1-MeV neutrons and comparing with theoretical simulations. The calculated and experimental dose rates were found to agree with a maximum deviation of 20% at certain locations. This study has served in benchmarking the Monte Carlo simulation methods adopted for shield design of such facilities. This has also helped in augmenting the existing shield thickness to reduce the neutron and associated gamma dose rates for radiological protection of personnel during operation of the generators at higher source neutron yields up to 1 × 1010 n/s.
Smith, James M; Ansari, Armin; Harper, Frederick T
2005-11-01
One of the key issues in the aftermath of an exploded radiological dispersal device from a terrorist event is that of the contaminated victim and the concern among healthcare providers for the harmful exposures they may receive in treating patients, especially if the patient has not been thoroughly decontaminated. This is critically important in the event of mass casualties from a nuclear or radiological incident because of the essential rapidity of acute medical decisions and that those who have life- or limb-threatening injuries may have treatment unduly delayed by a decontamination process that may be unnecessary for protecting the health and safety of the patient or the healthcare provider. To estimate potential contamination of those exposed in a radiological dispersal device event, results were used from explosive aerosolization tests of surrogate radionuclides detonated with high explosives at the Sandia National Laboratories. Computer modeling was also used to assess radiation dose rates to surgical personnel treating patients with blast injuries who are contaminated with any of a variety of common radionuclides. It is demonstrated that exceptional but plausible cases may require special precautions by the healthcare provider, even while managing life-threatening injuries of a contaminated victim from a radiological dispersal device event.
Current status of radiological protection at nuclear power stations in Japan.
Suzuki, Akira; Hori, Shunsuke
2011-07-01
The radiation dose to workers at nuclear power stations (NPSs) in Japan was drastically reduced between the late-1970s and the early-1990s by continuous dose-reduction programmes. The total collective dose of radiation workers in FY 2008 was 84.04 person Sv, while the average collective dose was 1.5 person Sv per reactor. The average annual individual dose was 1.1 mSv and the maximum annual individual dose was 19.5 mSv. These values are sufficiently lower than the regulatory dose limits. Radioactive effluent released from NPSs is already so trivial that additional protective measures will not be necessary. Experience in radiation protection at NPSs has been accumulated over 40 y and will be very useful in establishing a rational radiation control system in the future.
NASA Astrophysics Data System (ADS)
Lai, Lu-Han; Chuang, Keh-Shih; Lin, Hsin-Hon; Liu, Yi-Chi; Kuo, Chiung-Wen; Lin, Jao-Perng
2017-11-01
The in-vivo dose distributions of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), a newly developed technique, for head and neck cancer have been investigated for several years. The present study used a head-and-neck RANDO phantom to simulate the clinical conditions of nasopharyngeal carcinoma and compare the radiation doses between VMAT and IMRT. Three types of planning target volume (PTV) profiles were targeted by reducing the PTV surface margin by 0, 3, and 5 mm. An optically stimulated luminescence dosimeter was used to measure the surface doses. The results revealed that VMAT provided on average 16.8-13.8% lower surface doses within the PTV target areas than IMRT. When the PTV margin was reduced by 0 mm, the surface doses for IMRT reached their maximum value, accounting for 75.1% of its prescribed dose (Dp); however, the Dp value of VMAT was only 61.1%. When the PTV margin was reduced by 3 or 5 mm, the surface doses decreased considerably. The observed surface doses were insufficient when the tumours invaded the body surface; however, VMAT exerted larger skin-sparing effects than IMRT when the tumours away from the skin. These results suggest that the skin doses for these two techniques are insufficient for surface tumours. Notably, VMAT can provide lower skin doses for deep tumours.
Brandon, Catherine J; Mullan, Patricia B
2013-03-01
To better prepare radiology residents for providing care within the context of the larger health care system, this study evaluated the feasibility and impact of a curriculum to enhance radiology residents' understanding and ability to apply concepts from medical management and industrial and operational engineering to systems-based practice problems in radiology practice. A multiprofessional team including radiology, medical education, and industrial and operational engineering professionals collaborated in developing a seven-module curriculum, including didactic lectures, interactive large-group analysis, and small-group discussions with case-based radiology examples, which illustrated real-life management issues and the roles physicians held. Residents and faculty participated in topic selection. Pre- and post-instruction formative assessments were administered, and results were shared with residents during teaching sessions. Attendance and participation in case-based scenario resolutions indicate the feasibility and impact of the interactive curriculum on residents' interest and ability to apply curricular concepts to systems-based practice in radiology. Paired t test analyses (P < .05) and effect sizes showed residents significantly increased their knowledge and ability to apply concepts to systems-based practice issues in radiology. Our iterative curriculum development and implementation process demonstrated need and support for a multiprofessional team approach to teach management and operational engineering concepts. Curriculum topics are congruent with Accreditation Council for Graduate Medical Education requirements for systems-based practice. The case-based curriculum using a mixed educational format of didactic lectures and small-group discussion and problem analysis could be adopted for other radiology programs, for both residents and continuing medical education applications. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
Scherer, A; Kröpil, P; Heusch, P; Buchbender, C; Sewerin, P; Blondin, D; Lanzman, R S; Miese, F; Ostendorf, B; Bölke, E; Mödder, U; Antoch, G
2011-11-01
Medical curricula are currently being reformed in order to establish superordinated learning objectives, including, e.g., diagnostic, therapeutic and preventive competences. This requires a shifting from traditional teaching methods towards interactive and case-based teaching concepts. Conceptions, initial experiences and student evaluations of a novel radiological course Co-operative Learning In Clinical Radiology (CLICR) are presented in this article. A novel radiological teaching course (CLICR course), which combines different innovative teaching elements, was established and integrated into the medical curriculum. Radiological case vignettes were created for three clinical teaching modules. By using a PC with PACS (Picture Archiving and Communication System) access, web-based databases and the CASUS platform, a problem-oriented, case-based and independent way of learning was supported as an adjunct to the well established radiological courses and lectures. Student evaluations of the novel CLICR course and the radiological block course were compared. Student evaluations of the novel CLICR course were significantly better compared to the conventional radiological block course. Of the participating students 52% gave the highest rating for the novel CLICR course concerning the endpoint overall satisfaction as compared to 3% of students for the conventional block course. The innovative interactive concept of the course and the opportunity to use a web-based database were favorably accepted by the students. Of the students 95% rated the novel course concept as a substantial gain for the medical curriculum and 95% also commented that interactive working with the PACS and a web-based database (82%) promoted learning and understanding. Interactive, case-based teaching concepts such as the presented CLICR course are considered by both students and teachers as useful extensions to the radiological course program. These concepts fit well into competence-oriented curricula.
Herts, Brian R; Baker, Mark E; Obuchowski, Nancy; Primak, Andrew; Schneider, Erika; Rhana, Harpreet; Dong, Frank
2013-06-01
The purpose of this article is to determine the decrease in volume CT dose index (CTDI(vol)) and dose-length product (DLP) achieved by switching from fixed quality reference tube current protocols with automatic tube current modulation to protocols adjusting the quality reference tube current, slice collimation, and peak kilovoltage according to patient weight. All adult patients who underwent CT examinations of the abdomen or abdomen and pelvis during 2010 using weight-based protocols who also underwent a CT examination in 2008 or 2009 using fixed quality reference tube current protocols were identified from the radiology information system. Protocol pages were electronically retrieved, and the CT model, examination date, scan protocol, CTDI(vol), and DLP were extracted from the DICOM header or by optical character recognition. There were 15,779 scans with dose records for 2700 patients. Changes in CTDI(vol) and DLP were compared only between examinations of the same patient and same CT system model for examinations performed in 2008 or 2009 and those performed in 2010. The final analysis consisted of 1117 comparisons in 1057 patients, and 1209 comparisons in 988 patients for CTDI(vol) and DLP, respectively. The change to a weight-based protocol resulted in a statistically significant reduction in CTDI(vol) and DLP on three MDCT system models (p < 0.001). The largest average CTDI(vol) decrease was 13.9%, and the largest average DLP decrease was 16.1% on a 64-MDCT system. Both the CTDI(vol) and DLP decreased the most for patients who weighed less than 250 lb (112.5 kg). Adjusting the CT protocol by selecting parameters according to patient weight is a viable method for reducing CT radiation dose. The largest reductions occurred in the patients weighing less than 250 lb.
Berg, A; Pernkopf, M; Waldhäusl, C; Schmidt, W; Moser, E
2004-09-07
Precise methods of modem radiation therapy such as intensity modulated radiotherapy (IMRT), brachytherapy (BT) and high LET irradiation allow for high dose localization in volumes of a few mm3. However, most dosimetry methods-ionization chambers, TLD arrangements or silicon detectors, for example-are not capable of detecting sub-mm dose variations or do not allow for simple dose imaging. Magnetic resonance based polymer dosimetry (MRPD) appears to be well suited to three-dimensional high resolution relative dosimetry but the spatial resolution based on a systematic modulation transfer function (MTF) approach has not yet been investigated. We offer a theoretical construct for addressing the spatial resolution in different dose imaging systems, i.e. the dose modulation transfer function (DMTF) approach, an experimental realization of this concept with a phantom and quantitative comparisons between two dosimetric systems: polymer gel and film dosimetry. Polymer gel samples were irradiated by Co-60 photons through an absorber grid which is characterized by periodic structures of different spatial period (a), the smallest one at width of a/2 = 280 microm. The modulation in dose under the grid is visualized via calibrated, high resolution, parameter-selective (T2) and dose images based on multi-echo MR imaging. The DMTF is obtained from the modulation depth of the spin-spin relaxation time (T2) after calibration. Voxel sizes below 0.04 mm3 could be achieved, which are significantly smaller than those reported in MR based dose imaging on polymer gels elsewhere, using a powerful gradient system and a highly sensitive small birdcage resonator on a whole-body 3T MR scanner. Dose modulations at 22% of maximum dose amplitude could be observed at about 2 line pairs per mm. The polymer DMTF results are compared to those of a typical clinical film-scanner system. This study demonstrates that MR based gel dosimetry at 200 microm pixel resolution might even be superior, with reference to relative spatial resolution, to the results of a standard film-scanner system offering a nominal scan resolution of 200 microm.
Occupational exposure due to naturally occurring radionuclide material in granite quarry industry.
Ademola, J A
2012-02-01
The potential occupational exposure in granite quarry industry due to the presence of naturally occurring radioactive material (NORM) has been investigated. The activity concentrations of (40)K, (226)Ra and (232)Th were determined using gamma-ray spectroscopy method. The annual effective dose of workers through different exposure pathways was determined by model calculations. The total annual effective dose varied from 21.48 to 33.69 μSv y(-1). Inhalation dose contributes the highest to the total effective dose. The results obtained were much lower than the intervention exemption levels (1.0 mSv y(-1)) given in the International Commission on Radiological Protection Publication 82.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keller, Brian M.; Beachey, David J.; Pignol, Jean-Philippe
2007-10-15
Stereotactic radiosurgery is used to treat intracranial lesions with a high degree of accuracy. At the present time, x-ray energies at or above Co-60 gamma rays are used. Previous Monte Carlo simulations have demonstrated that intermediate energy x-ray photons or IEPs (defined to be photons in the energy range of 0.2-1.2 MeV), combined with small field sizes, produce a reduced radiological penumbra leading to a sharper dose gradient, improved dose homogeneity and sparing of critical anatomy adjacent to the target volume. This hypothesis is based on the fact that, for small x-ray fields, a dose outside the treatment volume ismore » dictated mainly by the range of electrons set into motion by x-ray photons. The purpose of this work is: (1) to produce intermediate energy x rays using a detuned medical linear accelerator (2) to characterize the energy of this beam (3) to measure the radiological penumbra for IEPs and small fields to compare with that produced by 6 MV x rays or Co-60, and (4) to compare these experimental measurements with Monte Carlo computer simulations. The maximum photon energy of our IEP x-ray spectrum was measured to be 1.2 MeV. Gafchromic EBT films (ISP Technologies, Wayne, NJ) were irradiated and read using a novel digital microscopy imaging system with high spatial resolution. Under identical irradiation conditions the measured radiological penumbra widths (80%-20% distance), for field sizes ranging from 0.3x0.3 to 4.0x4.0 cm{sup 2}, varied from 0.3-0.77 mm (1.2 MV) and from 1.1-2.1 mm (6 MV). Even more dramatic were the differences found when comparing the 90%-10% or the 95%-5% widths, which are in fact more significant in radiotherapy. Monte Carlo simulations agreed well with the experimental findings. The reduction in radiological penumbra could be substantial for specific clinical situations such as in the treatment of an ocular melanoma abutting the macula or for the treatment of functional disorders such as trigeminal neuralgia (a nonlethal neurological pathology) where no long-term side effect should be induced by the treatment.« less
Isik, Umit; Damla, Nevzat; Akkoca, Dicle Bal; Cevik, Uğur
2012-06-01
This work deals with the mineralogical, geochemical and radiological characterisations of Selmo Formation in Batman neighbourhood. The upper Miocene-Pliocene Selmo Formation is common in the centre of Batman and composed of carbonated sandy claystones and silty-sandy stone lenses. The common whole minerals of the samples are quartz, feldspars, calcite and dolomite. The clay minerals are smectite, illite, chlorite and mixed-layer clay (chlorite-smectite). The geochemical mean values of the samples are 51.7% SiO(2); 12.6% Al(2)O(3); 6.2% Fe(2)O(3); 3.6% MgO; 6.3% CaO; 1.1% Na(2)O; 1.7% K(2)O; 0.8% TiO(2); 0.2% P(2)O(5); 0.1% MnO; and 0.03% Cr(2)O(3). In addition, baseline maps for the concentrations of each radionuclide, the radium equivalent activity and the outdoor gamma dose rate distributions have been plotted for the study area. The mean activity concentrations of (226)Ra, (232)Th, (40)K and (137)Cs were determined to be 32, 24, 210 and 9 Bq kg(-1), respectively. The assessments of the radiological hazard indices, such as radium equivalent activity, absorbed dose rate in air, annual effective dose equivalent, excess lifetime cancer risk, external hazard index and internal hazard index, were calculated and compared with the internationally accepted reference values. This study shows that the concentrations of radioactivities in the measured samples were within the recommended safety limits and did not pose to be any significant source of radiation hazard.
Al-Jaseem, Q Kh; Almasoud, Fahad I; Ababneh, Anas M; Al-Hobaib, A S
2016-09-01
There is an increase demand for clean water sources in Saudi Arabia and, yet, renewable water resources are very limited. This has forced the authorities to explore deep groundwater which is known to contain large concentrations of radionuclides, mainly radium isotopes. Lately, there has been an increase in the number of water treatment plants (WTPs) around the country. In this study, a radiological assessment of a WTP in Saudi Arabia was performed. Raw water was found to have total radium activity of 0.23Bq/L, which exceeds the international limit of 0.185Bq/L (5pCi/L). The WTP investigated uses three stages of treatment: flocculation/sedimentation, sand filtration and reverse osmosis. The radium removal efficiency was evaluated for each stage and the respective values were 33%, 22% and 98%. Moreover, the activity of radium in the solid waste generated from the WTP in the sedimentation and sand filtrations stages were measured and found to be 4490 and 6750Bq/kg, respectively, which exceed the national limit of 1000Bq/kg for radioactive waste. A radiological assessment of the air inside the WTP was also performed by measuring the radon concentrations and dose rates and were found in the ranges of 2-18Bq/m(3) and 70-1000nSv/h, respectively. The annual effective dose was calculated and the average values was found to be 0.3mSv which is below the 1mSv limit. Copyright © 2016 Elsevier B.V. All rights reserved.
Radiologic-pathologic Correlation-An Advanced Fourth-year Elective: How We Do It.
Hartman, Matthew; Silverman, Jan; Spruill, Laura; Hill, Jeanne
2016-07-01
Traditionally, the radiology elective has been designed to teach medical students the fundamentals of radiologic interpretation. When questioned, many students state that they want to take a radiology elective so they can "interpret images." For the students on radiology, rotation/elective education was often passive, consisting of didactic conferences and observational shadowing of radiologists as they interpreted images. Students had only a superficial appreciation of how radiologists interacted with clinical services, multidisciplinary teams, and pathology. There was very little emphasis on imaging appropriateness or the most efficient and effective imaging for various clinical problems. With the expansion of numerous imaging modalities and the emphasis on patient-centered care, including imaging safety and dose reduction, it is important to change the focus of radiology education from interpretation to the optimal integration of imaging into clinical medicine. Radiology-pathology (rad path) electives were created at Allegheny General Hospital and the Medical University of South Carolina as a new option to provide a high-quality advanced elective for fourth-year medical students. These electives enable students to correlate radiologic images with gross and microscopic pathology specimens, thus increasing their knowledge and understanding of both. The rad path elective combines aspects of surgery, radiology, and pathology and requires students to be active learners. The implementation of this elective is an exciting work in progress that has been evolving over the past 2 and 4 years at Medical University of South Carolina and Allegheny General Hospital, respectively. We will discuss the historical basis for the elective, the advantages and challenges of having such an integrated course, and some different strategies for creating a rad path elective. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rehani, M.
2016-06-15
The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented.more » Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the global trend in the dose optimization and future prospectives. M. Rehani, The work was a part of the work of IAEA where I was an employee and IAEA is a United Nations organization.« less
MO-DE-204-02: Optimization of the Patient CT Dose in Europe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsapaki, V.
2016-06-15
The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented.more » Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the global trend in the dose optimization and future prospectives. M. Rehani, The work was a part of the work of IAEA where I was an employee and IAEA is a United Nations organization.« less
Gaujoux-Viala, Cécile; Rincheval, Nathalie; Dougados, Maxime; Combe, Bernard; Fautrel, Bruno
2017-12-01
Although methotrexate (MTX) is the consensual first-line disease-modifying antirheumatic drug (DMARD) for rheumatoid arthritis (RA), substantial heterogeneity remains with its prescription and dosage, which are often not optimal. To evaluate the symptomatic and structural impact of optimal MTX dose in patients with early RA in daily clinical practice over 2 years. Patients included in the early arthritis ESPOIR cohort who fulfilled the ACR-EULAR (American College of Rheumatology/European League against Rheumatism) criteria for RA and received MTX as a first DMARD were assessed. Optimal MTX dose was defined as ≥10 mg/week during the first 3 months, with escalation to ≥20 mg/week or 0.3 mg/kg/week at 6 months without Disease Activity Score in 28 joints remission. Symptomatic and structural efficacy with and without optimal MTX dose was assessed by generalised logistic regression with adjustment for appropriate variables. Within the first year of follow-up, 314 patients (53%) with RA received MTX as a first DMARD (mean dose 12.2±3.8 mg/week). Only 26.4% (n=76) had optimal MTX dose. After adjustment, optimal versus non-optimal MTX dose was more efficient in achieving ACR-EULAR remission at 1 year (OR 4.28 (95% CI 1.86 to 9.86)) and normal functioning (Health Assessment Questionnaire ≤0.5; OR at 1 year 4.36 (95% CI 2.03 to 9.39)), with no effect on radiological progression. Results were similar during the second year. Optimal MTX dose is more efficacious than non-optimal dose for remission and function in early arthritis in daily practice, with no impact on radiological progression over 2 years. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
SU-E-P-03: Implementing a Low Dose Lung Screening CT Program Meeting Regulatory Requirements
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFrance, M; Marsh, S; O'Donnell, G
Purpose: To provide information pertaining to IROC Houston QA Center's (RPC) credentialing process for institutions participating in NCI-sponsored clinical trials. Purpose: Provide guidance to the Radiology Departments with the intent of implementing a Low Dose CT Screening Program using different CT Scanners with multiple techniques within the framework of the required state regulations. Method: State Requirements for the purpose of implementing a Low Dose CT Lung Protocol required working with the Radiology and Pulmonary Department in setting up a Low Dose Screening Protocol designed to reduce the radiation burden to the patients enrolled. Radiation dose measurements (CTDIvol) for various CTmore » manufacturers (Siemens16, Siemens 64, Philips 64, and Neusoft128) for three different weight based protocols. All scans were reviewed by the Radiologist. Prior to starting a low dose lung screening protocol, information had to be submitted to the state for approval. Performing a Healing Arts protocol requires extensive information. This not only includes name and address of the applicant but a detailed description of the disease, the x-ray examination and the population to be examined. The unit had to be tested by a qualified expert using the technique charts. The credentials of all the operators, the supervisors and the Radiologists had to be submitted to the state. Results: All the appropriate documentation was sent to the state for review. The measured results between the Low Dose Protocol versus the default Adult Chest Protocol showed that there was a dose reduction of 65% for small (100-150 lb.) patient, 75% for the Medium patient (151-250 lbs.), and a 55% reduction for the Large patient ( over 250 lbs.). Conclusion: Measured results indicated that the Low Dose Protocol indeed lowered the screening patient's radiation dose and the institution was able to submit the protocol to the State's regulators.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumann, Frederic, E-mail: fredericbaumann@hotmail.com; Katzen, Barry T.; Carelsen, Bart
PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase).more » During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter.« less
Bolch, Wesley E.; Hurtado, Jorge L.; Lee, Choonsik; Manger, Ryan; Hertel, Nolan; Dickerson, William
2013-01-01
In June of 2006, the Radiation Studies Branch of the Centers for Disease Control and Prevention held a workshop to explore rapid methods of facilitating radiological triage of large numbers of potentially contaminated individuals following detonation of a radiological dispersal device. Two options were discussed. The first was the use of traditional gamma-cameras in nuclear medicine departments operated as make-shift whole-body counters. Guidance on this approach is currently available from the CDC. This approach is feasible if a manageable number of individuals were involved, transportation to the relevant hospitals was quickly provided, and the medical staff at each facility had been previously trained in this non-traditional use of their radiopharmaceutical imaging devices. If, however, substantially large numbers of individuals (100s to 1000s) needed radiological screening, other options must be given to first responders, first receivers, and health physicists providing medical management. In this study, the second option of the workshop was investigated – the use of commercially available portable survey meters (either NaI or GM based) for assessing potential ranges of effective dose (<50, 50–250, 250–500, and >500 mSv). Two hybrid computational phantoms were used to model an adult male and an adult female subject internally contaminated with either 241Am, 60Cs, 137Cs, 131I, and 192Ir following an acute inhalation or ingestion intake. As a function of time following the exposure, the net count rates corresponding to committed effective doses of 50, 250, and 500 mSv were estimated via Monte Carlo radiation transport simulation for each of four different detectors types, positions, and screening distances. Measured count rates can be compared to these values and an assignment of one of four possible effective dose ranges could be made. The method implicitly assumes that all external contamination has been removed prior to screening, and that the measurements be conducted in a low-background, and possibly mobile, facility positioned at the triage location. Net count rate data are provided in both tabular and graphical format within a series of eight handbooks available at the CDC website http://emergency.cdc.gov/radiation. PMID:22420020
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolch, W.E.; Hurtado, J.L.; Lee, C.
2012-01-01
In June 2006, the Radiation Studies Branch of the Centers for Disease Control and Prevention held a workshop to explore rapid methods of facilitating radiological triage of large numbers of potentially contaminated individuals following detonation of a radiological dispersal device. Two options were discussed. The first was the use of traditional gamma cameras in nuclear medicine departments operated as makeshift wholebody counters. Guidance on this approach is currently available from the CDC. This approach would be feasible if a manageable number of individuals were involved, transportation to the relevant hospitals was quickly provided, and the medical staff at each facilitymore » had been previously trained in this non-traditional use of their radiopharmaceutical imaging devices. If, however, substantially larger numbers of individuals (100 s to 1,000 s) needed radiological screening, other options must be given to first responders, first receivers, and health physicists providing medical management. In this study, the second option of the workshop was investigated by the use of commercially available portable survey meters (either NaI or GM based) for assessing potential ranges of effective dose (G50, 50Y250, 250Y500, and 9500 mSv). Two hybrid computational phantoms were used to model an adult male and an adult female subject internally contaminated with 241Am, 60Cs, 137Cs, 131I, or 192Ir following an acute inhalation or ingestion intake. As a function of time following the exposure, the net count rates corresponding to committed effective doses of 50, 250, and 500 mSv were estimated via Monte Carlo radiation transport simulation for each of four different detector types, positions, and screening distances. Measured net count rates can be compared to these values, and an assignment of one of four possible effective dose ranges could be made. The method implicitly assumes that all external contamination has been removed prior to screening and that the measurements be conducted in a low background, and possibly mobile, facility positioned at the triage location. Net count rate data are provided in both tabular and graphical format within a series of eight handbooks available at the CDC website (http://www.bt.cdc.gov/radiation/clinicians/evaluation).« less
Huang, Yang; Lowe, Henry J.; Klein, Dan; Cucina, Russell J.
2005-01-01
Objective: The aim of this study was to develop and evaluate a method of extracting noun phrases with full phrase structures from a set of clinical radiology reports using natural language processing (NLP) and to investigate the effects of using the UMLS® Specialist Lexicon to improve noun phrase identification within clinical radiology documents. Design: The noun phrase identification (NPI) module is composed of a sentence boundary detector, a statistical natural language parser trained on a nonmedical domain, and a noun phrase (NP) tagger. The NPI module processed a set of 100 XML-represented clinical radiology reports in Health Level 7 (HL7)® Clinical Document Architecture (CDA)–compatible format. Computed output was compared with manual markups made by four physicians and one author for maximal (longest) NP and those made by one author for base (simple) NP, respectively. An extended lexicon of biomedical terms was created from the UMLS Specialist Lexicon and used to improve NPI performance. Results: The test set was 50 randomly selected reports. The sentence boundary detector achieved 99.0% precision and 98.6% recall. The overall maximal NPI precision and recall were 78.9% and 81.5% before using the UMLS Specialist Lexicon and 82.1% and 84.6% after. The overall base NPI precision and recall were 88.2% and 86.8% before using the UMLS Specialist Lexicon and 93.1% and 92.6% after, reducing false-positives by 31.1% and false-negatives by 34.3%. Conclusion: The sentence boundary detector performs excellently. After the adaptation using the UMLS Specialist Lexicon, the statistical parser's NPI performance on radiology reports increased to levels comparable to the parser's native performance in its newswire training domain and to that reported by other researchers in the general nonmedical domain. PMID:15684131
Ruiz-Cruces, R; Vano, E; Carrera-Magariño, F; Moreno-Rodriguez, F; Soler-Cantos, M M; Canis-Lopez, M; Hernández-Armas, J; Diaz-Romero, F J; Rosales-Espizua, F; Fernandez-Soto, J M; Sanchez-Casanueva, R; Martin-Palanca, A; Perez-Martinez, M; Gil-Agudo, A; Zarca-Diaz, M A; Parra-Osorio, V; Muñoz Ruiz-Canela, J J; Moreno-Sanchez, T; Lopez-Medina, A; Moreno-Saiz, C; Galan-Montenegro, P; Gallego-Beuter, J J; Gonzalez-de-Garay, M; Zapata-Jimenez, J C; Pastor-Vega, J M; Cañete, S
2016-12-01
To propose national diagnostic reference levels (DRLs) for interventional radiology and to evaluate the impact of the procedural complexity on patient doses. Eight interventional radiology units from Spanish hospitals were involved in this project. The participants agreed to undergo common quality control procedures for X-ray systems. Kerma area product (KAP) was collected from a sample of 1,649 procedures. A consensus document established the criteria to evaluate the complexity of seven types of procedures. DRLs were set as the 3rd quartile of KAP values. The KAP (3rd quartile) in Gy cm 2 for the procedures included in the survey were: lower extremity arteriography (n = 784) 78; renal arteriography (n = 37) 107; transjugular hepatic biopsies (THB) (n = 30) 45; biliary drainage (BD) (n = 314) 30; uterine fibroid embolization (UFE) (n = 56) 214; colon endoprostheses (CE) (n = 31) 169; hepatic chemoembolization (HC) (n = 269) 303; femoropopliteal revascularization (FR) (n = 62) 119; and iliac stent (n = 66) 170. The complexity involved the increases in the following KAP factors from simple to complex procedures: THB x4; BD x13; UFE x3; CE x3; HC x5; FR x5 and IS x4. The evaluation of the procedure complexity in patient doses will allow the proper use of DRLs for the optimization of interventional radiology. • National DRLs for interventional procedures have been proposed given level of complexity • For clinical audits, the level of complexity should be taken into account. • An evaluation of the complexity levels of the procedure should be made.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rani, Asha, E-mail: ashasachdeva78@gmail.com; Mittal, Sudhir, E-mail: sudhirmittal03@gmail.com; Mehra, Rohit
In the present work, indoor radon and thoron measurements have been carried out from different locations of Jodhpur and Nagaur districts of Northern Rajasthan, India using RAD7, a solid state alpha detector. The radon and thoron concentration in indoor air varies from 8.75 to 61.25 Bq m{sup −3} and 32.7 to 147.2 Bq m{sup −3} with the mean value of 32 and 73 Bq m{sup −3} respectively. The observed indoor radon concentration values are well below the action level recommended by International Commission on Radiological Protection (200-300 Bq m{sup −3}) and Environmental Protection Agency (148 Bq m{sup −3}). The surveymore » reveals that the thoron concentration values in the indoor air are well within the International Commission on Radiological Protection (2005). The calculated total annual effective dose due to radon level in indoor air varies from 0.22 to 1.54 mSv y{sup −1} with the mean value of 0.81 mSv y{sup −1} which is less than even the lower limit of action level 3-10 mSv y{sup −1} recommended by International Commission on Radiological Protection (2005)« less
Modification of Shirt Buttons for Retrospective Radiation Dosimetry after a Radiological Event
Marino, Stephen A.; Johnson, Gary W.; Schiff, Peter B.; Brenner, David J.
2010-01-01
Preliminary results are presented for a personal radiation dosimeter in the form of a clothing button to provide gamma-ray dose estimation for clinically significant external radiation exposures to the general public due to a radiological incident, such as a Radiological Dispersal Device. Rods of thermoluminescent material (LiF:Mg,Ti and LiF:Mg,Cu,P) were encapsulated in plastic “buttons”, attached to shirts, and subjected to three cycles of home or commercial laundering or dry cleaning, including ironing or pressing. The buttons were subsequently exposed to doses of 137Cs gamma rays ranging from 0.75 to 8.2 Gy. The rods were removed from the buttons and their light output compared to their responses when bare or to the responses of a set of calibration rods of the same type and from the same manufacturer. In all three of the comparisons for LiF:Mg,Ti rods the relative responses of the rods in buttons changed by 2-6% relative to the same rods before cleaning. In both comparisons for LiF:Mg,Cu,P rods, the response of laundered rods was 1-3% lower than for the same rods before cleaning. Both these materials are potential candidates for button dosimeters. PMID:21451325
Zoetelief, J; Faulkner, K
2008-01-01
The past two decades have witnessed a technologically driven revolution in radiology. At the centre of these developments has been the use of computing. These developments have also been driven by the introduction of new detector and imaging devices in radiology and nuclear medicine, as well as the widespread application of computing techniques to enhance and extract information within the images acquired. Further advances have been introduced into digital practice. These technological developments, however, have not been matched by justification and optimisation studies to ensure that these new imaging devices and techniques are as effective as they might be, or performed at the lowest possible dose. The work programme of the SENTINEL Coordination Action was subdivided into eight work packages: functional performance and standards; efficacy and safety in digital radiology, dentistry and nuclear medicine, cardiology, interventional radiology, population screening/sensitive groups; justification, ethics and efficacy; good practice guidance and training; and project management. The intention of the work programme was to underwrite the safety, efficacy and ethical aspects of digital practice as well as to protect and add value to the equipment used in radiology.
A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology
NASA Astrophysics Data System (ADS)
Staton, R. J.; Pazik, F. D.; Nipper, J. C.; Williams, J. L.; Bolch, W. E.
2003-04-01
Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult.
Estimating Radiological Doses to Predators Foraging in a Low-Level Radioactive Waste Management Area
DOE Office of Scientific and Technical Information (OSTI.GOV)
L.Soholt; G.Gonzales; P.Fresquez
2003-03-01
Since 1957, Los Alamos National Laboratory has operated Area G as its low-level, solid radioactive waste management and disposal area. Although the waste management area is developed, plants, small mammals, and avian and mammalian predators still occupy the less disturbed and revegetated portions of the land. For almost a decade, we have monitored the concentrations of selected radionuclides in soils, plants, and small mammals at Area G. The radionuclides tritium, plutonium-238, and plutonium-239 are regularly found at levels above regional background in all three media. Based on radionuclide concentrations in mice collected from 1994 to 1999, we calculated doses tomore » higher trophic levels (owl, hawk, kestrel, and coyote) that forage on the waste management area. These predators play important functions in the regional ecosystems and are an important part of local Native American traditional tales that identify the uniqueness of their culture. The estimated doses are compared to Department of Energy's interim limit of 0.1 rad/day for the protection of terrestrial wildlife. We used exposure parameters that were derived from the literature for each receptor, including Environmental Protection Agency's exposure factors handbook. Estimated doses to predators ranged from 9E-06 to 2E-04 rad/day, assuming that they forage entirely on the waste management area. These doses are greater than those calculated for predators foraging exclusively in reference areas, but are still well below the interim dose limit. We believe that these calculated doses represent upper-bound estimates of exposure for local predators because the larger predators forage over areas that are much greater than the 63-acre waste management area. Based on these results, we concluded that predators foraging on this area do not face a hazard from radiological exposure under current site conditions.« less
Radiation Dose Reduction by Indication-Directed Focused z-Direction Coverage for Neck CT.
Parikh, A K; Shah, C C
2016-06-01
The American College of Radiology-American Society of Neuroradiology-Society for Pediatric Radiology Practice Parameter for a neck CT suggests that coverage should be from the sella to the aortic arch. It also recommends using CT scans judiciously to achieve the clinical objective. Our purpose was to analyze the potential dose reduction by decreasing the scan length of a neck CT and to assess for any clinically relevant information that might be missed from this modified approach. This retrospective study included 126 children who underwent a neck CT between August 1, 2013, and September 30, 2014. Alteration of the scan length for the modified CT was suggested on the topographic image on the basis of the indication of the study, with the reader blinded to the images and the report. The CT dose index volume of the original scan was multiplied by the new scan length to calculate the dose-length product of the modified study. The effective dose was calculated for the original and modified studies by using age-based conversion factors from the American Association of Physicists in Medicine Report No. 96. Decreasing the scan length resulted in an average estimated dose reduction of 47%. The average reduction in scan length was 10.4 cm, decreasing the overall coverage by 48%. The change in scan length did not result in any missed findings that altered management. Of the 27 abscesses in this study, none extended to the mediastinum. All of the lesions in question were completely covered. Decreasing the scan length of a neck CT according to the indication provides a significant savings in radiation dose, while not altering diagnostic ability or management. © 2016 by American Journal of Neuroradiology.
RCT: Module 2.03, Counting Errors and Statistics, Course 8768
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hillmer, Kurt T.
2017-04-01
Radiological sample analysis involves the observation of a random process that may or may not occur and an estimation of the amount of radioactive material present based on that observation. Across the country, radiological control personnel are using the activity measurements to make decisions that may affect the health and safety of workers at those facilities and their surrounding environments. This course will present an overview of measurement processes, a statistical evaluation of both measurements and equipment performance, and some actions to take to minimize the sources of error in count room operations. This course will prepare the student withmore » the skills necessary for radiological control technician (RCT) qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and by providing in the field skills.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Jeffrey M.; Handorf, Elizabeth A.; Price, Robert A.
A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 receivedmore » a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.« less
Gichoya, Judy Wawira; Kohli, Marc D; Haste, Paul; Abigail, Elizabeth Mills; Johnson, Matthew S
2017-10-01
Numerous initiatives are in place to support value based care in radiology including decision support using appropriateness criteria, quality metrics like radiation dose monitoring, and efforts to improve the quality of the radiology report for consumption by referring providers. These initiatives are largely data driven. Organizations can choose to purchase proprietary registry systems, pay for software as a service solution, or deploy/build their own registry systems. Traditionally, registries are created for a single purpose like radiation dosage or specific disease tracking like diabetes registry. This results in a fragmented view of the patient, and increases overhead to maintain such single purpose registry system by requiring an alternative data entry workflow and additional infrastructure to host and maintain multiple registries for different clinical needs. This complexity is magnified in the health care enterprise whereby radiology systems usually are run parallel to other clinical systems due to the different clinical workflow for radiologists. In the new era of value based care where data needs are increasing with demand for a shorter turnaround time to provide data that can be used for information and decision making, there is a critical gap to develop registries that are more adapt to the radiology workflow with minimal overhead on resources for maintenance and setup. We share our experience of developing and implementing an open source registry system for quality improvement and research in our academic institution that is driven by our radiology workflow.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.
PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremitymore » dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.« less
Kelsey, Chris R; Jackson, Lauren; Langdon, Scott; Owzar, Kouros; Hubbs, Jessica; Vujaskovic, Zeljko; Das, Shiva; Marks, Lawrence B
2012-02-01
To evaluate whether single nucleotide polymorphisms (SNPs) in the transforming growth factor-β1 (TGFβ1) gene are associated with radiation sensitivity using an objective radiologic endpoint. Preradiation therapy and serial postradiation therapy single photon emission computed tomography (SPECT) lung perfusion scans were obtained in patients undergoing treatment for lung cancer. Serial blood samples were obtained to measure circulating levels of TGFβ1. Changes in regional perfusion were related to regional radiation dose yielding a patient-specific dose-response curve, reflecting the patient's inherent sensitivity to radiation therapy. Six TGFβ1 SNPs (-988, -800, -509, 869, 941, and 1655) were assessed using high-resolution melting assays and DNA sequencing. The association between genotype and slope of the dose-response curve, and genotype and TGFβ1 ratio (4-week/preradiation therapy), was analyzed using the Kruskal-Wallis test. 39 white patients with preradiation therapy and ≥ 6-month postradiation therapy SPECT scans and blood samples were identified. Increasing slope of the dose-response curve was associated with the C(-509)T SNP (p = 0.035), but not the other analyzed SNPs. This SNP was also associated with higher TGFβ1 ratios. This study suggests that a polymorphism within the promoter of the TGFβ1 gene is associated with increased radiation sensitivity (defined objectively by dose-dependent changes in SPECT lung perfusion). Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Pereira, Wagner de S.; Kelecom, Alphonse; Py Júnior, Delcy de Azevedo
2008-08-01
The uranium mining at Caetité (Uranium Concentrate Unit—URA) is in its operational phase. Aiming to estimate the radiological environmental impact of the URA, a monitoring program is underway. In order to preserve the biota of the deleterious effects from radiation and to act in a pro-active way as expected from a licensing body, the present work aims to use an environmental protection methodology based on the calculation of absorbed dose rate in biota. Thus, selected target organism was the Tilapia fish (Tilapia nilotica, Linnaeus, 1758) and the radionuclides were: uranium (U-238), thorium (Th-232), radium (Ra-226 and Ra-228) and lead (Pb-210). As, in Brazil there are no radiation exposure limits adopted for biota the value proposed by the Department of Energy (DOE) of the United States of 3.5×103 μGy y-1 has been used. The derived absorbed dose rate calculated for Tilapia was 2.51×100 μGy y-1, that is less than 0.1% of the dose limit established by DOE. The critical radionuclide was Ra-226, with 56% of the absorbed dose rate, followed by U-238 with 34% and Th-232 with 9%. This value of 0.1% of the limit allows to state that, in the operational conditions analyzed, natural radionuclides do not represent a radiological problem to biota.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pereira, Wagner de S; Universidade Federal Fluminense, Programa de Pos-graduacao em Biologia Marinha; Kelecom, Alphonse
2008-08-07
The uranium mining at Caetite (Uranium Concentrate Unit--URA) is in its operational phase. Aiming to estimate the radiological environmental impact of the URA, a monitoring program is underway. In order to preserve the biota of the deleterious effects from radiation and to act in a pro-active way as expected from a licensing body, the present work aims to use an environmental protection methodology based on the calculation of absorbed dose rate in biota. Thus, selected target organism was the Tilapia fish (Tilapia nilotica, Linnaeus, 1758) and the radionuclides were: uranium (U-238), thorium (Th-232), radium (Ra-226 and Ra-228) and lead (Pb-210).more » As, in Brazil there are no radiation exposure limits adopted for biota the value proposed by the Department of Energy (DOE) of the United States of 3.5x10{sup 3} {mu}Gy y{sup -1} has been used. The derived absorbed dose rate calculated for Tilapia was 2.51x10{sup 0} {mu}Gy y{sup -1}, that is less than 0.1% of the dose limit established by DOE. The critical radionuclide was Ra-226, with 56% of the absorbed dose rate, followed by U-238 with 34% and Th-232 with 9%. This value of 0.1% of the limit allows to state that, in the operational conditions analyzed, natural radionuclides do not represent a radiological problem to biota.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelsey, Chris R., E-mail: kelse003@mc.duke.edu; Jackson, Lauren; Langdon, Scott
2012-02-01
Purpose: To evaluate whether single nucleotide polymorphisms (SNPs) in the transforming growth factor-{beta}1 (TGF{beta}1) gene are associated with radiation sensitivity using an objective radiologic endpoint. Methods and Materials: Preradiation therapy and serial postradiation therapy single photon emission computed tomography (SPECT) lung perfusion scans were obtained in patients undergoing treatment for lung cancer. Serial blood samples were obtained to measure circulating levels of TGF{beta}1. Changes in regional perfusion were related to regional radiation dose yielding a patient-specific dose-response curve, reflecting the patient's inherent sensitivity to radiation therapy. Six TGF{beta}1 SNPs (-988, -800, -509, 869, 941, and 1655) were assessed using high-resolutionmore » melting assays and DNA sequencing. The association between genotype and slope of the dose-response curve, and genotype and TGF{beta}1 ratio (4-week/preradiation therapy), was analyzed using the Kruskal-Wallis test. Results: 39 white patients with preradiation therapy and {>=}6-month postradiation therapy SPECT scans and blood samples were identified. Increasing slope of the dose-response curve was associated with the C(-509)T SNP (p = 0.035), but not the other analyzed SNPs. This SNP was also associated with higher TGF{beta}1 ratios. Conclusions: This study suggests that a polymorphism within the promoter of the TGF{beta}1 gene is associated with increased radiation sensitivity (defined objectively by dose-dependent changes in SPECT lung perfusion).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simeonov, Y; Penchev, P; Ringbaek, T Printz
2016-06-15
Purpose: Active raster scanning in particle therapy results in highly conformal dose distributions. Treatment time, however, is relatively high due to the large number of different iso-energy layers used. By using only one energy and the so called 3D range-modulator irradiation times of a few seconds only can be achieved, thus making delivery of homogeneous dose to moving targets (e.g. lung cancer) more reliable. Methods: A 3D range-modulator consisting of many pins with base area of 2.25 mm2 and different lengths was developed and manufactured with rapid prototyping technique. The form of the 3D range-modulator was optimised for a sphericalmore » target volume with 5 cm diameter placed at 25 cm in a water phantom. Monte Carlo simulations using the FLUKA package were carried out to evaluate the modulating effect of the 3D range-modulator and simulate the resulting dose distribution. The fine and complicated contour form of the 3D range-modulator was taken into account by a specially programmed user routine. Additionally FLUKA was extended with the capability of intensity modulated scanning. To verify the simulation results dose measurements were carried out at the Heidelberg Ion Therapy Center (HIT) with a 400.41 MeV 12C beam. Results: The high resolution measurements show that the 3D range-modulator is capable of producing homogeneous 3D conformal dose distributions, simultaneously reducing significantly irradiation time. Measured dose is in very good agreement with the previously conducted FLUKA simulations, where slight differences were traced back to minor manufacturing deviations from the perfect optimised form. Conclusion: Combined with the advantages of very short treatment time the 3D range-modulator could be an alternative to treat small to medium sized tumours (e.g. lung metastasis) with the same conformity as full raster-scanning treatment. Further simulations and measurements of more complex cases will be conducted to investigate the full potential of the 3D range-modulator.« less
Anigstein, Robert; Olsher, Richard H; Loomis, Donald A; Ansari, Armin
2016-12-01
The detonation of a radiological dispersion device or other radiological incidents could result in widespread releases of radioactive materials and intakes of radionuclides by affected individuals. Transportable radiation monitoring instruments could be used to measure radiation from gamma-emitting radionuclides in the body for triaging individuals and assigning priorities to their bioassay samples for in vitro assessments. The present study derived sets of calibration factors for four instruments: the Ludlum Model 44-2 gamma scintillator, a survey meter containing a 2.54 × 2.54-cm NaI(Tl) crystal; the Captus 3000 thyroid uptake probe, which contains a 5.08 × 5.08-cm NaI(Tl) crystal; the Transportable Portal Monitor Model TPM-903B, which contains two 3.81 × 7.62 × 182.9-cm polyvinyltoluene plastic scintillators; and a generic instrument, such as an ionization chamber, that measures exposure rates. The calibration factors enable these instruments to be used for assessing inhaled or ingested intakes of any of four radionuclides: Co, I, Cs, and Ir. The derivations used biokinetic models embodied in the DCAL computer software system developed by the Oak Ridge National Laboratory and Monte Carlo simulations using the MCNPX radiation transport code. The three physical instruments were represented by MCNP models that were developed previously. The affected individuals comprised children of five ages who were represented by the revised Oak Ridge National Laboratory pediatric phantoms, and adult men and adult women represented by the Adult Reference Computational Phantoms described in Publication 110 of the International Commission on Radiological Protection. These calibration factors can be used to calculate intakes; the intakes can be converted to committed doses by the use of tabulated dose coefficients. These calibration factors also constitute input data to the ICAT computer program, an interactive Microsoft Windows-based software package that estimates intakes of radionuclides and cumulative and committed effective doses, based on measurements made with these instruments. This program constitutes a convenient tool for assessing intakes and doses without consulting tabulated calibration factors and dose coefficients.
Anigstein, Robert; Olsher, Richard H.; Loomis, Donald A.; Ansari, Armin
2017-01-01
The detonation of a radiological dispersion device or other radiological incidents could result in widespread releases of radioactive materials and intakes of radionuclides by affected individuals. Transportable radiation monitoring instruments could be used to measure radiation from gamma-emitting radionuclides in the body for triaging individuals and assigning priorities to their bioassay samples for in vitro assessments. The present study derived sets of calibration factors for four instruments: the Ludlum Model 44-2 gamma scintillator, a survey meter containing a 2.54 × 2.54-cm NaI(Tl) crystal; the Captus 3000 thyroid uptake probe, which contains a 5.08 × 5.08-cm NaI(Tl) crystal; the Transportable Portal Monitor Model TPM-903B, which contains two 3.81 × 7.62 × 182.9-cm polyvinyltoluene plastic scintillators; and a generic instrument, such as an ionization chamber, that measures exposure rates. The calibration factors enable these instruments to be used for assessing inhaled or ingested intakes of any of four radionuclides: 60Co, 131I, 137Cs, and 192Ir. The derivations used biokinetic models embodied in the DCAL computer software system developed by the Oak Ridge National Laboratory and Monte Carlo simulations using the MCNPX radiation transport code. The three physical instruments were represented by MCNP models that were developed previously. The affected individuals comprised children of five ages who were represented by the revised Oak Ridge National Laboratory pediatric phantoms, and adult men and adult women represented by the Adult Reference Computational Phantoms described in Publication 110 of the International Commission on Radiological Protection. These calibration factors can be used to calculate intakes; the intakes can be converted to committed doses by the use of tabulated dose coefficients. These calibration factors also constitute input data to the ICAT computer program, an interactive Microsoft Windows-based software package that estimates intakes of radionuclides and cumulative and committed effective doses, based on measurements made with these instruments. This program constitutes a convenient tool for assessing intakes and doses without consulting tabulated calibration factors and dose coefficients. PMID:27798478
Radiation dose to the global flying population.
Alvarez, Luis E; Eastham, Sebastian D; Barrett, Steven R H
2016-03-01
Civil airliner passengers and crew are exposed to elevated levels of radiation relative to being at sea level. Previous studies have assessed the radiation dose received in particular cases or for cohort studies. Here we present the first estimate of the total radiation dose received by the worldwide civilian flying population. We simulated flights globally from 2000 to 2013 using schedule data, applying a radiation propagation code to estimate the dose associated with each flight. Passengers flying in Europe and North America exceed the International Commission on Radiological Protection annual dose limits at an annual average of 510 or 420 flight hours per year, respectively. However, this falls to 160 or 120 h on specific routes under maximum exposure conditions.
OSL studies of local bricks for retrospective dosimetric application
NASA Astrophysics Data System (ADS)
Singh, A. K.; Menon, S. N.; Kadam, S. Y.; Koul, D. K.; Datta, D.
2016-09-01
Luminescence properties of quartz extracted from bricks has been reported worldwide for its use in dose estimation in case of nuclear or radiological accident. Accordingly, in this study the feasibility of utilizing the optically stimulated luminescence (OSL) emission of quartz extracted from red bricks collected from three different locations in and around Mumbai, India for retrospective dosimetry was explored. Thermoluminescence and OSL characterization of the samples were carried out. The growth curve, thermal stability and equivalent dose plateau of the OSL signal suggested the signals to be well behaving. Subsequently, the dose recovery tests carried for different administered doses, using single aliquot regenerative protocol, demonstrated the feasibility of the OSL emissions of these samples for dose evaluation in retrospective dosimetry.
Medical imaging: Material change for X-ray detectors
NASA Astrophysics Data System (ADS)
Rowlands, John A.
2017-10-01
The X-ray sensitivity of radiology instruments is limited by the materials used in their detectors. A material from the perovskite family of semiconductors could allow lower doses of X-rays to be used for medical imaging. See Letter p.87
Qu, Xing-min; Li, Gang; Ludlow, John B; Zhang, Zu-yan; Ma, Xu-chen
2010-12-01
The aim of this study was to compare effective doses resulting from different scan protocols for cone-beam computerized tomography (CBCT) using International Commission on Radiological Protection (ICRP) 1990 and 2007 calculations of dose. Average tissue-absorbed dose, equivalent dose, and effective dose for a ProMax 3D CBCT with different dental protocols were calculated using thermoluminescent dosimeter chips in a human equivalent phantom. Effective doses were derived using ICRP 1990 and the superseding 2007 recommendations. Effective doses (ICRP 2007) for default patient sizes from small to large ranged from 102 to 298 μSv. The coefficient of determination (R(2)) between tube current and effective dose (ICRP 2007) was 0.90. When scanning with lower resolution settings, the effective doses were reduced significantly (P < .05). ProMax 3D can provide a wide range of radiation dose levels. Reduction in radiation dose can be achieved when using lower settings of exposure parameters. Copyright © 2010 Mosby, Inc. All rights reserved.
A Multiple Parameters Biodosimetry Tool with Various Blood Cell Counts - the Hemodose Approach
NASA Technical Reports Server (NTRS)
Hu, Shaowen
2014-01-01
There continue to be important concerns about the possibility of the occurrence of acute radiation syndromes following nuclear and radiological terrorism or accidents that may result in mass casualties in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine radiation induced biological changes to assess the severity of radiation injury to sensitive organ systems. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced bone marrow injury. This is due to the fact that the hematopoietic system is the most vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as a practical and recommended laboratory test to estimate radiation dose and injury. Based upon years of physiological and pathophysiological investigation of mammalian hematopoietic systems, and rigorous coarse-grained bio-mathematical modeling and validation on species from mouse, to dog, monkey, and human, we have developed a set of software tools Hemodose, which can use single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure to estimate absorbed doses of adult victims very rapidly and accurately. Some patient data from historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large-scale radiological disaster scenario. Most significant to the improvement of national and local preparedness of a potential nuclear/radiological disaster, this HemoDose approach establishes robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in the very late phase (up to 4 weeks) after exposure.
Radiological properties of MAGIC normoxic polymer gel dosimetry
NASA Astrophysics Data System (ADS)
Aljamal, M.; Zakaria, A.; Shamsuddin, S.
2013-04-01
For a polymer gel dosimeter to be of use in radiation dosimetry, it should display water-equivalent radiological properties. In this study, the radiological properties of the MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper) normoxic polymer gels were investigated. The mass density (ρ) was determined based on Archimedes' principle. The weight fraction of elemental composition and the effective atomic number (Zeff) were calculated. The electron density was also measured with 90° scattering angle at room temperature. The linear attenuation coefficient (μ) of unirradiated gel, irradiated gel, and water were determined using Am-241 based on narrow beam geometry. Monte Carlo simulation was used to calculate the depth doses response of MAGIC gel and water for 6MV photon beam. The weight fractions of elements composition of MAGIC gel were close to that for water. The mass density was found to be 1027 ± 2 kg m-3, which is also very close to mass density of muscle tissue (1030 kg m-3) and 2.7% higher than that of water. The electron density (ρe) and atomic number (Zeff) were found to be 3.43 × 1029 e m-3 and 7.105, respectively. The electron density measured was 2.6% greater than that for water. The atomic number was very close to that for water. The prepared MAGIC gel was found to be water equivalent based on the study of element composition, mass density, electron density and atomic number. The linear attenuation coefficient of unirradiated gel was very close to that of water. The μ of irradiated gel was found to be linear with dose 2-40 Gy. The depth dose response for MAGIC gel from a 6 MV photon beam had a percentage dose difference to water of less than 1%. Therefore it satisfies the criteria to be a good polymer gel dosimeter for radiotherapy.
Nedveckaite, T; Gudelis, A; Vives i Batlle, J
2013-05-01
This work describes the radiological assessment of the near-surface Maisiagala radioactive waste repository (Lithuania) over the period 2005-2012, with focus on water pathways and special emphasis on tritium. The study includes an assessment of the effect of post-closure upgrading, the durability of which is greater than 30 years. Both human and terrestrial non-human biota are considered, with local low-intensity forestry and small farms being the area of concern. The radiological exposure was evaluated using the RESRAD-OFFSITE, RESRAD-BIOTA and ERICA codes in combination with long-term data from a dedicated environmental monitoring programme. All measurements were performed at the Lithuanian Institute of Physics as part of this project. It is determined that, after repository upgrading, radiological exposure to humans are significantly lower than the human dose constraint of 0.2 mSv/year valid in the Republic of Lithuania. Likewise, for non-human biota, dose rates are below the ERICA/PROTECT screening levels. The potential annual effective inhalation dose that could be incurred by the highest-exposed human individual (which is due to tritiated water vapour airborne release over the most exposed area) does not exceed 0.1 μSv. Tritium-labelled drinking water appears to be the main pathway for human impact, representing about 83 % of the exposure. Annual committed effective dose (CED) values for members of the public consuming birch sap as medical practice are calculated to be several orders of magnitude below the CEDs for the same location associated with drinking of well water. The data presented here indicate that upper soil-layer samples may not provide a good indication of potential exposure to terrestrial deep-rooted trees, as demonstrated by an investigation of stratified (3)H in soil moisture, expressed on a wet soil mass basis, in an area with subsurface contamination.
SU-E-T-41: Analysis of GI Dose Variability Due to Intrafraction Setup Variance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, J; Wolfgang, J
2014-06-01
Purpose: Proton SBRT (stereotactic body radiation therapy) can be an effective modality for treatment of gastrointestinal tumors, but limited in practice due to sensitivity with respect to variation in the RPL (radiological path length). Small, intrafractional shifts in patient anatomy can lead to significant changes in the dose distribution. This study describes a tool designed to visualize uncertainties in radiological depth in patient CT's and aid in treatment plan design. Methods: This project utilizes the Shadie toolkit, a GPU-based framework that allows for real-time interactive calculations for volume visualization. Current SBRT simulation practice consists of a serial CT acquisition formore » the assessment of inter- and intra-fractional motion utilizing patient specific immobilization systems. Shadie was used to visualize potential uncertainties, including RPL variance and changes in gastric content. Input for this procedure consisted of two patient CT sets, contours of the desired organ, and a pre-calculated dose. In this study, we performed rigid registrations between sets of 4DCT's obtained from a patient with varying setup conditions. Custom visualizations are written by the user in Shadie, permitting one to create color-coded displays derived from a calculation along each ray. Results: Serial CT data acquired on subsequent days was analyzed for variation in RPB and gastric content. Specific shaders were created to visualize clinically relevant features, including RPL (radiological path length) integrated up to organs of interest. Using pre-calculated dose distributions and utilizing segmentation masks as additional input allowed us to further refine the display output from Shadie and create tools suitable for clinical usage. Conclusion: We have demonstrated a method to visualize potential uncertainty for intrafractional proton radiotherapy. We believe this software could prove a useful tool to guide those looking to design treatment plans least insensitive to motion for patients undergoing proton SBRT in the GI tract.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NSTec Environmental Restoration
Homeland Security Presidential Directive HSPD-5 requires all federal departments and agencies to adopt a National Incident Management System (NIMS)/Incident Command System (ICS) and use it in their individual domestic incident management and emergency prevention, preparedness, response, recovery, and mitigation programs and activities, as well as in support of those actions taken to assist state and local entities. This system provides a consistent nationwide template to enable federal, state, local, and tribal governments, private-sector, and nongovernmental organizations to work together effectively and efficiently to prepare for, prevent, respond to, and recover from domestic incidents, regardless of cause, size, or complexity, includingmore » acts of catastrophic terrorism. This document identifies the operational concepts of the Federal Radiological Monitoring and Assessment Center's (FRMAC) implementation of the NIMS/ICS response structure under the National Response Plan (NRP). The construct identified here defines the basic response template to be tailored to the incident-specific response requirements. FRMAC's mission to facilitate interagency environmental data management, monitoring, sampling, analysis, and assessment and link this information to the planning and decision staff clearly places the FRMAC in the Planning Section. FRMAC is not a mitigating resource for radiological contamination but is present to conduct radiological impact assessment for public dose avoidance. Field monitoring is a fact-finding mission to support this effort directly. Decisions based on the assessed data will drive public protection and operational requirements. This organizational structure under NIMS is focused by the mission responsibilities and interface requirements following the premise to provide emergency responders with a flexible yet standardized structure for incident response activities. The coordination responsibilities outlined in the NRP are based on the NIMS/ICS construct and Unified Command (UC) for management of a domestic incident. The NRP Nuclear/Radiological Incident Annex (NUC) further provides requirements and protocols for coordinating federal government capabilities to respond to nuclear/radiological Incidents of National Significance (INS) and other radiological incidents. When a FRMAC is established, it operates under the parameters of NIMS as defined in the NRP. FRMAC and its operations have been modified to reflect NIMS/ICS concepts and principles and to facilitate working in a Unified Command structure. FRMAC is established at or near the scene of the incident to coordinate radiological monitoring and assessment and is established in coordination with the U.S. Department of Homeland Security (DHS); the coordinating agency; other federal agencies; and state, local, and tribal authorities. However, regardless of the coordinating agency designation, U.S. Department of Energy (DOE) coordinates radiological monitoring and assessment activities for the initial phases of the offsite federal incident response through the Radiological Assistance Program (RAP) and FRMAC assets. Monitoring and assessment data are managed by FRMAC in an accountable, secure, and retrievable format. Monitoring data interpretations, including exposure rate contours, dose projections, and any requested radiological assessments are to be provided to the DHS; to the coordinating agency; and to state, local, and tribal government agencies.« less
Lumbreras, B; Vilar, J; González-Álvarez, I; Guilabert, M; Parker, L A; Pastor-Valero, M; Domingo, M L; Fernández-Lorente, M F; Hernández-Aguado, I
2016-01-01
Objectives To assess the impact of initiatives aiming to increase clinician awareness of radiation exposure; to explore the challenges they face when communicating with patients; to study what they think is the most appropriate way of communicating the long-term potential risks of medical radiological exposure to patients. Design A quantitative and qualitative evaluation through a survey and focal groups. Setting San Juan Hospital and Dr Peset Hospital (Southeast Spain) and clinicians from Spanish scientific societies. Participants The surveys were answered (a) in person (216: all the radiologists (30), urologists (14) and surgeons (44) working at both participant hospitals; a sample of general practitioners from the catchment area of one hospital (45), and a consecutive sample of radiologists attending a scientific meeting (60)) or (b) electronically through Spanish scientific societies (299: radiologists (45), pneumologists (123), haematologists (75) and surgeons (40)). Clinicians were not randomly selected and thus the results are limited by the diligence of the individuals filling out the survey. Primary and secondary outcome measures Clinicians' knowledge and practices regarding medical radiological exposure, and what they considered most appropriate for communicating information to patients. Results Nearly 80% of the clinicians surveyed had never heard of the European recommendations. Fewer than 20% of the clinicians surveyed identified correctly the radiation equivalence dose of intravenous urography or barium enema. It was reported by 31.7% that they inform patients about the long-term potential risks of ionising radiation. All participants agreed that the most appropriate way to present information is a table with a list of imaging tests and their corresponding radiation equivalence dose in terms of chest X-rays and background radiation exposure. Conclusions Medical radiological exposure is frequently underestimated and rarely explained to patients. With a clear understanding of medical radiological exposure and proper communication tools, clinicians will be able to accurately inform patients. PMID:27799242
NASA Astrophysics Data System (ADS)
Huang, Shengzhou; Li, Mujun; Shen, Lianguan; Qiu, Jinfeng; Zhou, Youquan
2018-03-01
A novel fabrication method for high quality aspheric microlens array (MLA) was developed by combining the dose-modulated DMD-based lithography and surface thermal reflow process. In this method, the complex shape of aspheric microlens is pre-modeled via dose modulation in a digital micromirror device (DMD) based maskless projection lithography. And the dose modulation mainly depends on the distribution of exposure dose of photoresist. Then the pre-shaped aspheric microlens is polished by a following non-contact thermal reflow (NCTR) process. Different from the normal process, the reflow process here is investigated to improve the surface quality while keeping the pre-modeled shape unchanged, and thus will avoid the difficulties in generating the aspheric surface during reflow. Fabrication of a designed aspheric MLA with this method was demonstrated in experiments. Results showed that the obtained aspheric MLA was good in both shape accuracy and surface quality. The presented method may be a promising approach in rapidly fabricating high quality aspheric microlens with complex surface.
NASA Astrophysics Data System (ADS)
Akahane, Keiichi; Yonai, Shunsuke; Fukuda, Shigekazu; Miyahara, Nobuyuki; Yasuda, Hiroshi; Iwaoka, Kazuki; Matsumoto, Masaki; Fukumura, Akifumi; Akashi, Makoto
2013-04-01
The great east Japan earthquake and subsequent tsunamis caused Fukushima Dai-ichi Nuclear Power Plant (NPP) accident. National Institute of Radiological Sciences (NIRS) developed the external dose estimation system for Fukushima residents. The system is being used in the Fukushima health management survey. The doses can be obtained by superimposing the behavior data of the residents on the dose rate maps. For grasping the doses, 18 evacuation patterns of the residents were assumed by considering the actual evacuation information before using the survey data. The doses of the residents from the deliberate evacuation area were relatively higher than those from the area within 20 km radius. The estimated doses varied from around 1 to 6 mSv for the residents evacuated from the representative places in the deliberate evacuation area. The maximum dose in 18 evacuation patterns was estimated to be 19 mSv.
Akahane, Keiichi; Yonai, Shunsuke; Fukuda, Shigekazu; Miyahara, Nobuyuki; Yasuda, Hiroshi; Iwaoka, Kazuki; Matsumoto, Masaki; Fukumura, Akifumi; Akashi, Makoto
2013-01-01
The great east Japan earthquake and subsequent tsunamis caused Fukushima Dai-ichi Nuclear Power Plant (NPP) accident. National Institute of Radiological Sciences (NIRS) developed the external dose estimation system for Fukushima residents. The system is being used in the Fukushima health management survey. The doses can be obtained by superimposing the behavior data of the residents on the dose rate maps. For grasping the doses, 18 evacuation patterns of the residents were assumed by considering the actual evacuation information before using the survey data. The doses of the residents from the deliberate evacuation area were relatively higher than those from the area within 20 km radius. The estimated doses varied from around 1 to 6 mSv for the residents evacuated from the representative places in the deliberate evacuation area. The maximum dose in 18 evacuation patterns was estimated to be 19 mSv.
Stochastic Modeling of Radioactive Material Releases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andrus, Jason; Pope, Chad
2015-09-01
Nonreactor nuclear facilities operated under the approval authority of the U.S. Department of Energy use unmitigated hazard evaluations to determine if potential radiological doses associated with design basis events challenge or exceed dose evaluation guidelines. Unmitigated design basis events that sufficiently challenge dose evaluation guidelines or exceed the guidelines for members of the public or workers, merit selection of safety structures, systems, or components or other controls to prevent or mitigate the hazard. Idaho State University, in collaboration with Idaho National Laboratory, has developed a portable and simple to use software application called SODA (Stochastic Objective Decision-Aide) that stochastically calculatesmore » the radiation dose associated with hypothetical radiological material release scenarios. Rather than producing a point estimate of the dose, SODA produces a dose distribution result to allow a deeper understanding of the dose potential. SODA allows users to select the distribution type and parameter values for all of the input variables used to perform the dose calculation. SODA then randomly samples each distribution input variable and calculates the overall resulting dose distribution. In cases where an input variable distribution is unknown, a traditional single point value can be used. SODA was developed using the MATLAB coding framework. The software application has a graphical user input. SODA can be installed on both Windows and Mac computers and does not require MATLAB to function. SODA provides improved risk understanding leading to better informed decision making associated with establishing nuclear facility material-at-risk limits and safety structure, system, or component selection. It is important to note that SODA does not replace or compete with codes such as MACCS or RSAC, rather it is viewed as an easy to use supplemental tool to help improve risk understanding and support better informed decisions. The work was funded through a grant from the DOE Nuclear Safety Research and Development Program.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kofler, J.
The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented.more » Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the global trend in the dose optimization and future prospectives. M. Rehani, The work was a part of the work of IAEA where I was an employee and IAEA is a United Nations organization.« less
Guidelines for Posting Soil Contamination Areas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mcnaughton, Michael; Eisele, William
All soil guidelines were determined using RESRAD, version 6.1. All offsite guidelines are based on 15 mrem/year. This dose rate is sufficiently low to protect human health and is in accordance with DOE guidance and the proposed EPA 40-CFR-196 regulations for members of the public (never promulgated). For those onsite areas where general employees (non-radiological workers) could have routine access, soil concentrations should be based on a dose rate of 30 mrem/year (approximately one-third of the onsite LANL non-radiological worker dose of 100 mrem/year). In this case, soil concentration guidelines may be obtained by doubling the 15 mrem/year guidelines. Severalmore » scenarios were developed to provide maximum flexibility for application of the guidelines. The offsite guidelines were developed using: residential scenarios for both adults and children; a construction worker scenario; a resource user (e.g., a hunter) scenario; a child playing within canyon reaches scenario, a trail using jogger within canyon reaches scenario, and a trail using hiker within canyon reaches scenario. The residential guidelines represent the lowest values from both the adult residential scenario and the child residential scenario.« less
[CAS in rhino-surgical procedures in the growing age].
Schipper, J; Maier, W; Gellrich, N-C; Arapakis, I; Hochmuth, A; Laszig, R
2005-01-01
Rhinosurgery in children and adolescents meets special requirements: Limited cooperation and reduced limits for the organ dose for ionizing radiological examinations aggravate diagnostics. On the other side, bone sutures and bone growth areas have to be respected intraoperatively, and regions of bones not yet calcified have to be distinguished from possible tumor infiltration. Computer assisted surgery (CAS) can help to identify these areas safely. 5 patients, from the first to the 20 (th) year of life, suffering from tumors, malformation syndromes or therapy resistant nasal polyposis were treated with CAS in rhinosurgery. In addition to radiological diagnostics, we performed 3D computed tomography of the skull for CAS. CAS enabled us to intraoperatively respect possible areas of bone growth, to identify regions with thin, not bonily developed cranial vault and to safely distinguish bone sutures from ethmoidal cells. CAS helped the surgeon to navigate in the not yet developed paranasal sinus system. CAS is a useful complementary method in rhinosurgery of the developing skull of the child. In spite of the additional 3D computed tomography, the calculated organ dose of the ocular lense amounted to 5 millisievert, so a recommended maximal organ dose for the ocular lense of 15 millisievert was not exceeded.
Anissi, H D; Geibel, M A
2014-08-01
The purpose of this study was to gain insight into the distribution and application of digital intraoral radiographic techniques within general dental practices and to compare these with film-based systems in terms of patient dose reduction. 1100 questionnaires were handed out to general dental practitioners. Data was analyzed with respect to the type of system by using descriptive statistics and nonparametric tests, i.e. Kruskal-Wallis, Mann-Whitney and chi-square test (SPSS 20). 64% of the questioned dentists still use film-based radiology, 23% utilize storage phosphor plate (SPP) systems and 13% use a charge-coupled device (CCD). A strong correlation between the number of dentists working in a practice and the use of digital dental imaging was observed. Almost 3/4 of the film users work with E- or F-speed film. 45% of them refuse to change to a digital system. The use of lead aprons was popular, while only a minority preferred thyroid shields and rectangular collimators. A fourfold reduction of exposure time from D-speed film to CCD systems was observed. Due to detector size and positioning errors, users of CCD systems take significantly more single-tooth radiographs in total. Considering the number of radiographs per patient, there is only a slight tendency towards more X-rays with CCD systems. Up to image generation, digital systems seem to be as or even more difficult to handle than film-based systems, while their handling was favored after radiographic exposure. Despite a slight increase of radiographs taken with CCD systems, there is a significant dosage reduction. Corresponding to the decrease in exposure time, the patient dose for SPP systems is reduced to one half compared to film. The main issues in CCD technology are positioning errors and the size of the X-ray detectors which are difficult to eliminate. The usage of radiation protection measures still needs to be improved. ► Responsible use of digital intraoral radiology results in a significant dose reduction in everyday practice. ► The ALARA principle is only achieved by strict implementation of dose-reducing methods. ► The efforts to use dose-reducing devices must be increased. © Georg Thieme Verlag KG Stuttgart · New York.
Leung, H W C; Chan, A L F; Chang, M B
2016-05-01
We examined the effects of intensity-modulated radiation therapy with dose-sparing and avoidance technique on a pediatric patient with localized intracranial germinoma. We also reviewed the literature regarding modern irradiation techniques in relation to late neurocognitive sequelae. A patient with a localized intracranial germinoma in the third ventricle anterior to the pineal gland received a dose-sparing intensity-modulated radiation therapy. The planning was compared to the radiation oncologist's guide of organs at risk and dose constraints for dosimetric analyses. The patient received radiation therapy alone. The total dose was 54Gy delivered in 2.0Gy fractions to the primary tumour and 37Gy in 1.4Gy fractions to whole ventricles using a dose-sculpting plan. Dosimetry analyses showed that dose-sparing intensity-modulated radiation therapy delivered reduced doses to the whole brain, temporal lobes, hippocampi, cochleae, and optic nerves. With a follow-up of 22 months, failure-free survival was 100% for the patient and no adverse events during radiation treatment process. Intensity-modulated radiation therapy with dose sparing and avoidance technique can spare the limbic circuit, central nervous system, and hippocampus for pineal germ cell tumours. This technique reduces the integral dose delivered to the uninvolved normal brain tissues and may reduce late neurocognitive sequelae caused by cranial radiotherapy. Copyright © 2016 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, X; Sun, T; Yin, Y
Purpose: To study the dosimetric impact of intensity-modulated radiotherapy (IMRT), hybrid intensity-modulated radiotherapy (h-IMRT) and volumetric modulated arc therapy(VMAT) for whole-brain radiotherapy (WBRT) with simultaneous integrated boost in patients with multiple brain metastases. Methods: Ten patients with multiple brain metastases were included in this analysis. The prescribed dose was 45 Gy to the whole brain (PTVWBRT) and 55 Gy to individual brain metastases (PTVboost) delivered simultaneously in 25 fractions. Three treatment techniques were designed: the 7 equal spaced fields IMRT plan, hybrid IMRT plan and VMAT with two 358°arcs. In hybrid IMRT plan, two fields(90°and 270°) were planned to themore » whole brain. This was used as a base dose plan. Then 5 fields IMRT plan was optimized based on the two fields plan. The dose distribution in the target, the dose to the organs at risk and total MU in three techniques were compared. Results: For the target dose, conformity and homogeneity in PTV, no statistically differences were observed in the three techniques. For the maximum dose in bilateral lens and the mean dose in bilateral eyes, IMRT and h-IMRT plans showed the highest and lowest value respectively. No statistically significant differences were observed in the dose of optic nerve and brainstem. For the monitor units, IMRT and VMAT plans showed the highest and lowest value respectively. Conclusion: For WBRT with simultaneous integrated boost in patients with multiple brain metastases, hybrid IMRT could reduce the doses to lens and eyes. It is feasible for patients with brain metastases.« less
NASA Astrophysics Data System (ADS)
Lee, Choonsik; Lee, Choonik; Han, Eun Young; Bolch, Wesley E.
2007-01-01
The effective dose recommended by the International Commission on Radiological Protection (ICRP) is the sum of organ equivalent doses weighted by corresponding tissue weighting factors, wT. ICRP is in the process of revising its 1990 recommendations on the effective dose where new values of organs and tissue weighting factors have been proposed and published in draft form for consultation by the radiological protection community. In its 5 June 2006 draft recommendations, new organs and tissues have been introduced in the effective dose which do not exist within the 1987 Oak Ridge National Laboratory (ORNL) phantom series (e.g., salivary glands). Recently, the investigators at University of Florida have updated the series of ORNL phantoms by implementing new organ models and adopting organ-specific elemental composition and densities. In this study, the effective dose changes caused by the transition from the current recommendation of ICRP Publication 60 to the 2006 draft recommendations were investigated for external photon irradiation across the range of ICRP reference ages (newborn, 1-year, 5-year, 10-year, 15-year and adult) and for six idealized irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), left-lateral (LLAT), right-lateral (RLAT), rotational (ROT) and isotropic (ISO). Organ-absorbed doses were calculated by implementing the revised ORNL phantoms in the Monte Carlo radiation transport code, MCNPX2.5, after which effective doses were calculated under the 1990 and draft 2006 evaluation schemes of the ICRP. Effective doses calculated under the 2006 draft scheme were slightly higher than estimated under ICRP Publication 60 methods for all irradiation geometries exclusive of the AP geometry where an opposite trend was observed. The effective doses of the adult phantom were more greatly affected by the change in tissue weighting factors than that seen within the paediatric members of the phantom series. Additionally, dose conversion coefficients for newly identified radiosensitive organs—salivary glands, gall bladder, heart and prostate—were reported, as well as the brain, which was originally considered in ICRP Publication 60 as a member of the remainder category of the effective dose.
Design of a modulated orthovoltage stereotactic radiosurgery system.
Fagerstrom, Jessica M; Bender, Edward T; Lawless, Michael J; Culberson, Wesley S
2017-07-01
To achieve stereotactic radiosurgery (SRS) dose distributions with sharp gradients using orthovoltage energy fluence modulation with inverse planning optimization techniques. A pencil beam model was used to calculate dose distributions from an orthovoltage unit at 250 kVp. Kernels for the model were derived using Monte Carlo methods. A Genetic Algorithm search heuristic was used to optimize the spatial distribution of added tungsten filtration to achieve dose distributions with sharp dose gradients. Optimizations were performed for depths of 2.5, 5.0, and 7.5 cm, with cone sizes of 5, 6, 8, and 10 mm. In addition to the beam profiles, 4π isocentric irradiation geometries were modeled to examine dose at 0.07 mm depth, a representative skin depth, for the low energy beams. Profiles from 4π irradiations of a constant target volume, assuming maximally conformal coverage, were compared. Finally, dose deposition in bone compared to tissue in this energy range was examined. Based on the results of the optimization, circularly symmetric tungsten filters were designed to modulate the orthovoltage beam across the apertures of SRS cone collimators. For each depth and cone size combination examined, the beam flatness and 80-20% and 90-10% penumbrae were calculated for both standard, open cone-collimated beams as well as for optimized, filtered beams. For all configurations tested, the modulated beam profiles had decreased penumbra widths and flatness statistics at depth. Profiles for the optimized, filtered orthovoltage beams also offered decreases in these metrics compared to measured linear accelerator cone-based SRS profiles. The dose at 0.07 mm depth in the 4π isocentric irradiation geometries was higher for the modulated beams compared to unmodulated beams; however, the modulated dose at 0.07 mm depth remained <0.025% of the central, maximum dose. The 4π profiles irradiating a constant target volume showed improved statistics for the modulated, filtered distribution compared to the standard, open cone-collimated distribution. Simulations of tissue and bone confirmed previously published results that a higher energy beam (≥ 200 keV) would be preferable, but the 250 kVp beam was chosen for this work because it is available for future measurements. A methodology has been described that may be used to optimize the spatial distribution of added filtration material in an orthovoltage SRS beam to result in dose distributions with decreased flatness and penumbra statistics compared to standard open cones. This work provides the mathematical foundation for a novel, orthovoltage energy fluence-modulated SRS system. © 2017 American Association of Physicists in Medicine.
The influence of plan modulation on the interplay effect in VMAT liver SBRT treatments.
Hubley, Emily; Pierce, Greg
2017-08-01
Volumetric modulated arc therapy (VMAT) uses multileaf collimator (MLC) leaves, gantry speed, and dose rate to modulate beam fluence, producing the highly conformal doses required for liver radiotherapy. When targets that move with respiration are treated with a dynamic fluence, there exists the possibility for interplay between the target and leaf motions. This study employs a novel motion simulation technique to determine if VMAT liver SBRT plans with an increase in MLC leaf modulation are more susceptible to dosimetric differences in the GTV due to interplay effects. For ten liver SBRT patients, two VMAT plans with different amounts of MLC leaf modulation were created. Motion was simulated using a random starting point in the respiratory cycle for each fraction. To isolate the interplay effect, motion was also simulated using four specific starting points in the respiratory cycle. The dosimetric differences caused by different starting points were examined by subtracting resultant dose distributions from each other. When motion was simulated using random starting points for each fraction, or with specific starting points, there were significantly more dose differences in the GTV (maximum 100cGy) for more highly modulated plans, but the overall plan quality was not adversely affected. Plans with more MLC leaf modulation are more susceptible to interplay effects, but dose differences in the GTV are clinically negligible in magnitude. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Radiological protection and medical dosimetry for the Skylab crewmen
NASA Technical Reports Server (NTRS)
Bailey, J. V.; Hoffman, R. A.; English, R. A.
1977-01-01
Dosimetry results for Skylab crewmembers show that the Skylab 4 crewmen received the highest dose equivalents but remained well within the established limits for Skylab missions below the threshold of significant clinical effects. These dose equivalents apply specificially to long term effects such as general life shortening, increased neoplasm incidence, and cataract production. A Skylab crewman could fly a mission comparable to one 84-day Skylab 4 mission per year for 50 years before exceeding these career limits.
Characterisation of an anthropomorphic chest phantom for dose measurements in radiology beams
NASA Astrophysics Data System (ADS)
Henriques, L. M. S.; Cerqueira, R. A. D.; Santos, W. S.; Pereira, A. J. S.; Rodrigues, T. M. A.; Carvalho Júnior, A. B.; Maia, A. F.
2014-02-01
The objective of this study was to characterise an anthropomorphic chest phantom for dosimetric measurements of conventional radiology beams. This phantom was developed by a previous research project at the Federal University of Sergipe for image quality control tests. As the phantom consists of tissue-equivalent material, it is possible to characterise it for dosimetric studies. For comparison, a geometric chest phantom, consisting of PMMA (polymethylmethacrylate) with dimensions of 30×30×15 cm³ was used. Measurements of incident air kerma (Ki) and entrance surface dose (ESD) were performed using ionisation chambers. From the results, backscatter factors (BSFs) of the two phantoms were determined and compared with values estimated by CALDose_X software, based on a Monte Carlo simulation. For the technical parameters evaluated in this study, the ESD and BSF values obtained experimentally showed a good similarity between the two phantoms, with minimum and maximum difference of 0.2% and 7.0%, respectively, and showed good agreement with the results published in the literature. Organ doses and effective doses for the anthropomorphic phantom were also estimated by the determination of conversion coefficients (CCs) using the visual Monte Carlo (VMC) code. Therefore, the results of this study prove that the anthropomorphic thorax phantom proposed is a good tool to use in dosimetry and can be used for risk evaluation of X-ray diagnostic procedures.
RENEB - Running the European Network of biological dosimetry and physical retrospective dosimetry.
Kulka, Ulrike; Abend, Michael; Ainsbury, Elizabeth; Badie, Christophe; Barquinero, Joan Francesc; Barrios, Lleonard; Beinke, Christina; Bortolin, Emanuela; Cucu, Alexandra; De Amicis, Andrea; Domínguez, Inmaculada; Fattibene, Paola; Frøvig, Anne Marie; Gregoire, Eric; Guogyte, Kamile; Hadjidekova, Valeria; Jaworska, Alicja; Kriehuber, Ralf; Lindholm, Carita; Lloyd, David; Lumniczky, Katalin; Lyng, Fiona; Meschini, Roberta; Mörtl, Simone; Della Monaca, Sara; Monteiro Gil, Octávia; Montoro, Alegria; Moquet, Jayne; Moreno, Mercedes; Oestreicher, Ursula; Palitti, Fabrizio; Pantelias, Gabriel; Patrono, Clarice; Piqueret-Stephan, Laure; Port, Matthias; Prieto, María Jesus; Quintens, Roel; Ricoul, Michelle; Romm, Horst; Roy, Laurence; Sáfrány, Géza; Sabatier, Laure; Sebastià, Natividad; Sommer, Sylwester; Terzoudi, Georgia; Testa, Antonella; Thierens, Hubert; Turai, Istvan; Trompier, François; Valente, Marco; Vaz, Pedro; Voisin, Philippe; Vral, Anne; Woda, Clemens; Zafiropoulos, Demetre; Wojcik, Andrzej
2017-01-01
A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios. The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices. Communication and cross-border collaboration were also standardized. To assure long-term sustainability of the network, cooperation with national and international emergency preparedness organizations was initiated and links to radiation protection and research platforms have been developed. A legal framework, based on a Memorandum of Understanding, was established and signed by 27 organizations by the end of 2015. RENEB is a European Network of biological and physical-retrospective dosimetry, with the capacity and capability to perform large-scale rapid individualized dose estimation. Specialized to handle large numbers of samples, RENEB is able to contribute to radiological emergency preparedness and wider large-scale research projects.
Landsberger, S; Sharp, A; Wang, S; Pontikes, Y; Tkaczyk, A H
2017-07-01
This study employs thermal and epithermal neutron activation analysis (NAA) to quantitatively and specifically determine absorption dose rates to various body parts from uranium, thorium and potassium. Specifically, a case study of bauxite residue (red mud) from an industrial facility was used to demonstrate the feasibility of the NAA approach for radiological safety assessment, using small sample sizes to ascertain the activities of 235 U, 238 U, 232 Th and 40 K. This proof-of-concept was shown to produce reliable results and a similar approach could be used for quantitative assessment of other samples with possible radiological significance. 238 U and 232 Th were determined by epithermal and thermal neutron activation analysis, respectively. 235 U was determined based on the known isotopic ratio of 238 U/ 235 U. 40 K was also determined using epithermal neutron activation analysis to measure total potassium content and then subtracting its isotopic contribution. Furthermore, the work demonstrates the application of Monte Carlo Neutral-Particle (MCNP) simulations to estimate the radiation dose from large quantities of red mud, to assure the safety of humans and the surrounding environment. Phantoms were employed to observe the dose distribution throughout the human body demonstrating radiation effects on each individual organ. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ramos, Miguel; Montoro, Alegria; Almonacid, Miguel; Ferrer, Silvia; Barquinero, Joan Francesc; Tortosa, Ricardo; Verdú, Gumersindo; Rodríguez, Pilar; Barrios, Lleonard; Villaescusa, Juan Ignacio
2008-01-01
Interventional radiologists and staff members are frequently exposed to protracted and fractionated low doses of ionizing radiation, which extend during all their professional activities. These exposures can derive, due to the irradiation of skin tissues and peripheral blood, in deterministic effects (radiodermitis, aged skin, hands depilation) or stochastic ones (skin and non-solid cancers incidence). Epidemiological studies of population exposed to ionizing radiation provide information of radio-induced effects. The radiation risk or radiological detriment has been estimated from a group of six exposed interventionist radiologists of the Hospital La Fe (Valencia, Spain). Dosimetry has been periodically registered from TLDs and wrist dosimeters (physical methods) and estimated through translocations in lymphocytes of peripheral blood (biological methods), by extrapolating the yield of translocations to their respective dose-effect curves. The probability of non-melanoma skin cancer and leukaemia (acute myelogenous, acute lymphocytic and chronic myelogenous leukaemia) incidence has been estimated through the software RADRISK. This software is based on a transport model from epidemiological studies of population exposed to external low-LET ionizing radiation [1]. Other non-solid carcinomas have not been considered due to their low statistical power, such as myeloid and non-Hodgkin lymphomas. The discrepancies observed between the physically recorded doses and biological estimated doses could indicate that exposed workers did not always wear their dosimeters or these dosimeters were not always exposed to the radiation field.
Improved neutron activation prediction code system development
NASA Technical Reports Server (NTRS)
Saqui, R. M.
1971-01-01
Two integrated neutron activation prediction code systems have been developed by modifying and integrating existing computer programs to perform the necessary computations to determine neutron induced activation gamma ray doses and dose rates in complex geometries. Each of the two systems is comprised of three computational modules. The first program module computes the spatial and energy distribution of the neutron flux from an input source and prepares input data for the second program which performs the reaction rate, decay chain and activation gamma source calculations. A third module then accepts input prepared by the second program to compute the cumulative gamma doses and/or dose rates at specified detector locations in complex, three-dimensional geometries.
Optimization of combined electron and photon beams for breast cancer
NASA Astrophysics Data System (ADS)
Xiong, W.; Li, J.; Chen, L.; Price, R. A.; Freedman, G.; Ding, M.; Qin, L.; Yang, J.; Ma, C.-M.
2004-05-01
Recently, intensity-modulated radiation therapy and modulated electron radiotherapy have gathered a growing interest for the treatment of breast and head and neck tumours. In this work, we carried out a study to combine electron and photon beams to achieve differential dose distributions for multiple target volumes simultaneously. A Monte Carlo based treatment planning system was investigated, which consists of a set of software tools to perform accurate dose calculation, treatment optimization, leaf sequencing and plan analysis. We compared breast treatment plans generated using this home-grown optimization and dose calculation software for different treatment techniques. Five different planning techniques have been developed for this study based on a standard photon beam whole breast treatment and an electron beam tumour bed cone down. Technique 1 includes two 6 MV tangential wedged photon beams followed by an anterior boost electron field. Technique 2 includes two 6 MV tangential intensity-modulated photon beams and the same boost electron field. Technique 3 optimizes two intensity-modulated photon beams based on a boost electron field. Technique 4 optimizes two intensity-modulated photon beams and the weight of the boost electron field. Technique 5 combines two intensity-modulated photon beams with an intensity-modulated electron field. Our results show that technique 2 can reduce hot spots both in the breast and the tumour bed compared to technique 1 (dose inhomogeneity is reduced from 34% to 28% for the target). Techniques 3, 4 and 5 can deliver a more homogeneous dose distribution to the target (with dose inhomogeneities for the target of 22%, 20% and 9%, respectively). In many cases techniques 3, 4 and 5 can reduce the dose to the lung and heart. It is concluded that combined photon and electron beam therapy may be advantageous for treating breast cancer compared to conventional treatment techniques using tangential wedged photon beams followed by a boost electron field.
[E-Learning in radiology; the practical use of the content management system ILIAS].
Schütze, B; Mildenberger, P; Kämmerer, M
2006-05-01
Due to the possibility of using different kinds of visualization, e-learning has the advantage of allowing individualized learning. A check should be performed to determine whether the use of the web-based content management system ILIAS simplifies the writing and production of electronic learning modules in radiology. Internet-based e-learning provides access to existing learning modules regardless of time and location, since fast Internet connections are readily available. Web Content Management Systems (WCMS) are suitable platforms for imparting radiology-related information (visual abilities like the recognition of patterns as well as interdisciplinary specialized knowledge). The open source product ILIAS is a free WCMS. It is used by many universities and is accepted by both students and lecturers. Its modular and object-oriented software architecture makes it easy to adapt and enlarge the platform. The employment of e-learning standards such as LOM and SCORM within ILIAS makes it possible to reuse contents, even if the platform has to be changed. ILIAS renders it possible to provide students with texts, images, or files of any other kind within a learning context which is defined by the lecturer. Students can check their acquired knowledge via online testing and receive direct performance feedback. The significant interest that students have shown in ILIAS proves that e-learning can be a useful addition to conventional learning methods.
Mail, Noor; Shamy, Abdulrahman M.; Alghamdi, Suliman; Saoudi, Abdelhamid
2016-01-01
Image quality is a key issue in radiology, particularly in a clinical setting where it is important to achieve accurate diagnoses while minimizing radiation dose. Some computed tomography (CT) manufacturers have introduced algorithms that claim significant dose reduction. In this study, we assessed CT image quality produced by two reconstruction algorithms provided with GE Healthcare's Discovery 690 Elite positron emission tomography (PET) CT scanner. Image quality was measured for images obtained at various doses with both conventional filtered back‐projection (FBP) and adaptive statistical iterative reconstruction (ASIR) algorithms. A standard CT dose index (CTDI) phantom and a pencil ionization chamber were used to measure the CT dose at 120 kVp and an exposure of 260 mAs. Image quality was assessed using two phantoms. CT images of both phantoms were acquired at tube voltage (kV) of 120 with exposures ranging from 25 mAs to 400 mAs. Images were reconstructed using FBP and ASIR ranging from 10% to 100%, then analyzed for noise, low‐contrast detectability, contrast‐to‐noise ratio (CNR), and modulation transfer function (MTF). Noise was 4.6 HU in water phantom images acquired at 260 mAs/FBP 120 kV and 130 mAs/50% ASIR 120 kV. The large objects (frequency<7 lp/cm) retained fairly acceptable image quality at 130 mAs/50% ASIR, compared to 260 mAs/FBP. The application of ASIR for small objects (frequency>7 lp/cm) showed poor visibility compared to FBP at 260 mAs and even worse for images acquired at less than 130 mAs. ASIR blending more than 50% at low dose tends to reduce contrast of small objects (frequency>7 lp/cm). We concluded that dose reduction and ASIR should be applied with close attention if the objects to be detected or diagnosed are small (frequency>7 lp/cm). Further investigations are required to correlate the small objects (frequency>7 lp/cm) to patient anatomy and clinical diagnosis. PACS number(s): 87.57.‐s, 87.57.C, 87.57.cf, 87.57.cj, 87.57.cm, 87.57.cp, 87.57.N, 87.57.nf, 87.57.np, 87.57.nt, 87.57.Q, 87.59.‐e, 87.59.B PMID:27167261
Petrinec, Branko; Sovilj, Marina Poje; Babić, Dinko; Meštrović, Tomislav; Miklavčić, Igor; Radolić, Vanja; Stanić, Denis; Vuković, Branko; Šoštarić, Marko
2018-06-05
A study of the environmental radioactivity in the Kopački Rit Nature Park, Croatia, is presented. This wildlife reserve is part of the Middle Danube River Basin, and it is exposed to various pollutants due to a number of human activities in the surroundings, where there is a nuclear power plant and also urban centres and areas of intense agricultural production. Results for the activity concentrations of soil and surface water samples do not indicate any elevated radioactivity level, which is confirmed by on-site measurements of ambient dose rate equivalent. An assessment of the radiological load on the local biota, carried out using the ERICA tool, implies an overall low radiological risk even if conservative values of the risk quotient are used. Therefore, human activities do not have a significant effect on the radiological load on the Kopački Rit area. A similar conclusion might be made with regard to numerous similar environments in the Middle Danube River Basin.
Hussein, M; Aldridge, S; Guerrero Urbano, T; Nisbet, A
2012-01-01
Objective The aim of this study was to investigate the effect of 6 and 15-MV photon energies on intensity-modulated radiation therapy (IMRT) prostate cancer treatment plan outcome and to compare the theoretical risks of secondary induced malignancies. Methods Separate prostate cancer IMRT plans were prepared for 6 and 15-MV beams. Organ-equivalent doses were obtained through thermoluminescent dosemeter measurements in an anthropomorphic Aldersen radiation therapy human phantom. The neutron dose contribution at 15 MV was measured using polyallyl-diglycol-carbonate neutron track etch detectors. Risk coefficients from the International Commission on Radiological Protection Report 103 were used to compare the risk of fatal secondary induced malignancies in out-of-field organs and tissues for 6 and 15 MV. For the bladder and the rectum, a comparative evaluation of the risk using three separate models was carried out. Dose–volume parameters for the rectum, bladder and prostate planning target volume were evaluated, as well as normal tissue complication probability (NTCP) and tumour control probability calculations. Results There is a small increased theoretical risk of developing a fatal cancer from 6 MV compared with 15 MV, taking into account all the organs. Dose–volume parameters for the rectum and bladder show that 15 MV results in better volume sparing in the regions below 70 Gy, but the volume exposed increases slightly beyond this in comparison with 6 MV, resulting in a higher NTCP for the rectum of 3.6% vs 3.0% (p=0.166). Conclusion The choice to treat using IMRT at 15 MV should not be excluded, but should be based on risk vs benefit while considering the age and life expectancy of the patient together with the relative risk of radiation-induced cancer and NTCPs. PMID:22010028
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brady, S. L.; Yee, B. S.; Kaufman, R. A.
Purpose: This study demonstrates a means of implementing an adaptive statistical iterative reconstruction (ASiR Trade-Mark-Sign ) technique for dose reduction in computed tomography (CT) while maintaining similar noise levels in the reconstructed image. The effects of image quality and noise texture were assessed at all implementation levels of ASiR Trade-Mark-Sign . Empirically derived dose reduction limits were established for ASiR Trade-Mark-Sign for imaging of the trunk for a pediatric oncology population ranging from 1 yr old through adolescence/adulthood. Methods: Image quality was assessed using metrics established by the American College of Radiology (ACR) CT accreditation program. Each image quality metricmore » was tested using the ACR CT phantom with 0%-100% ASiR Trade-Mark-Sign blended with filtered back projection (FBP) reconstructed images. Additionally, the noise power spectrum (NPS) was calculated for three common reconstruction filters of the trunk. The empirically derived limitations on ASiR Trade-Mark-Sign implementation for dose reduction were assessed using (1, 5, 10) yr old and adolescent/adult anthropomorphic phantoms. To assess dose reduction limits, the phantoms were scanned in increments of increased noise index (decrementing mA using automatic tube current modulation) balanced with ASiR Trade-Mark-Sign reconstruction to maintain noise equivalence of the 0% ASiR Trade-Mark-Sign image. Results: The ASiR Trade-Mark-Sign algorithm did not produce any unfavorable effects on image quality as assessed by ACR criteria. Conversely, low-contrast resolution was found to improve due to the reduction of noise in the reconstructed images. NPS calculations demonstrated that images with lower frequency noise had lower noise variance and coarser graininess at progressively higher percentages of ASiR Trade-Mark-Sign reconstruction; and in spite of the similar magnitudes of noise, the image reconstructed with 50% or more ASiR Trade-Mark-Sign presented a more smoothed appearance than the pre-ASiR Trade-Mark-Sign 100% FBP image. Finally, relative to non-ASiR Trade-Mark-Sign images with 100% of standard dose across the pediatric phantom age spectrum, similar noise levels were obtained in the images at a dose reduction of 48% with 40% ASIR Trade-Mark-Sign and a dose reduction of 82% with 100% ASIR Trade-Mark-Sign . Conclusions: The authors' work was conducted to identify the dose reduction limits of ASiR Trade-Mark-Sign for a pediatric oncology population using automatic tube current modulation. Improvements in noise levels from ASiR Trade-Mark-Sign reconstruction were adapted to provide lower radiation exposure (i.e., lower mA) instead of improved image quality. We have demonstrated for the image quality standards required at our institution, a maximum dose reduction of 82% can be achieved using 100% ASiR Trade-Mark-Sign ; however, to negate changes in the appearance of reconstructed images using ASiR Trade-Mark-Sign with a medium to low frequency noise preserving reconstruction filter (i.e., standard), 40% ASiR Trade-Mark-Sign was implemented in our clinic for 42%-48% dose reduction at all pediatric ages without a visually perceptible change in image quality or image noise.« less
Apsalikov, Bakytbek; Manambaeva, Zukhra; Ospanov, Erlan; Massabayeva, Meruyert; Zhabagin, Kuantkan; Zhagiparova, Zhanar; Maximov, Vladymir; Voropaeva, Elena; Apsalikov, Kazbek; Belikhina, Tatiana; Abdrahmanov, Ramil; Cherepkova, Elena; Tanatarov, Sayat; Massadykov, Adilzhan; Urazalina, Naylia
2016-01-01
Frequencies of polymorphisms of genes BRCA1 and TP53 in breast cancer (BC) patients with a BC family history and radiation history were assessed and compared in the Semey region of Kazakhstan. The study included 60 women directly irradiated by the activities of the Semipalatinsk test site with a calculated effective equivalent dose of 500 mSv and their first generation descendants (group BC+Her+Exp); 65 women with family BC and absence of radiological history - the effective equivalent dose due to anthropogenic sources not exceeding 50 mSv (group BC+Her-Exp). The comparison group consisted of 65 women patients with breast cancer without family and radiological history (BC-Her-Exp). The control group comprised 60 women without breast cancer and without family and radiological history (nonBC). We carried out the genotyping of the polymorphisms c.2311T>C, c.4308T>C and 5382insC of the BRCA1 gene and rs1042522 of the TP53 gene. The frequency of the polymorphism c.2311T>C was significantly higher in patients of the group BC+Her+Exp than in healthy women, and of the polymorphism 5382insC in BC+Her+Exp compared to all other groups. The frequency of the rs1042522 polymorphism of TP53 was significantly higher in all groups of patients with breast cancer compared with the control group. Differences between groups of women with breast cancer were significant only in BC+Her+Exp vs. BC+Her-Exp. Combinations of polymorphisms of the genes BRCA1 and TP53 predominated in women with a family and radiological history.
NASA Astrophysics Data System (ADS)
Szumska, A.; Budzanowski, M.; Kopeć, R.
2017-11-01
In its statement on tissue reactions approved on 21st April 2011, the International Commission on Radiological Protection (ICRP, 2012) reviewed its recommendation concerning the equivalent dose limit for the eye lens and reduced the dose limits for occupationally exposed persons to 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv. This limit was approved and written down in the new EURATOM (European Atomic Energy Community) directive 2013/59 and in the IAEA (International Atomic Energy Agency) BSS (Basic Safety Standard) of July 2014. For that reason, the necessity to monitor the eye lens may become more important than it was before. However, specially dedicated dosemeters for the dose quantity Hp(3) are using very rarely. Commonly use are only whole body personal dosemeters for the personal dose equivalent quantities Hp(10) worn on the trunk and ring dosemeters worn on finger to measure the quantity Hp(0.07). Therefore, in this work it was investigated whether dosemeters from routine use calibrated in terms of Hp(10) and Hp(0.07) and worn on thyroid collar and protective apron could deliver similar results like dedicated eye lens dosemeter worn close to the eyes. The results show that the best method if dedicated eye lens dosimeters is not used is to measure doses in terms of Hp(0.07) on the thyroid collar (Pearson product, r=0.85). Obtained results shows also importance of proper localization of eye lens dosimeter (close to the eye, from side of the X-ray source).
[Diagnostic reference levels in interventional radiology].
Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I
2013-12-01
This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
Radiation exposure from diagnostic imaging in young patients with testicular cancer.
Sullivan, C J; Murphy, K P; McLaughlin, P D; Twomey, M; O'Regan, K N; Power, D G; Maher, M M; O'Connor, O J
2015-04-01
Risks associated with high cumulative effective dose (CED) from radiation are greater when imaging is performed on younger patients. Testicular cancer affects young patients and has a good prognosis. Regular imaging is standard for follow-up. This study quantifies CED from diagnostic imaging in these patients. Radiological imaging of patients aged 18-39 years, diagnosed with testicular cancer between 2001 and 2011 in two tertiary care centres was examined. Age at diagnosis, cancer type, dose-length product (DLP), imaging type, and frequency were recorded. CED was calculated from DLP using conversion factors. Statistical analysis was performed with SPSS. In total, 120 patients with a mean age of 30.7 ± 5.2 years at diagnosis had 1,410 radiological investigations. Median (IQR) surveillance was 4.37 years (2.0-5.5). Median (IQR) CED was 125.1 mSv (81.3-177.5). Computed tomography accounted for 65.3 % of imaging studies and 98.3 % of CED. We found that 77.5 % (93/120) of patients received high CED (>75 mSv). Surveillance time was associated with high CED (OR 2.1, CI 1.5-2.8). Survivors of testicular cancer frequently receive high CED from diagnostic imaging, mainly CT. Dose management software for accurate real-time monitoring of CED and low-dose CT protocols with maintained image quality should be used by specialist centres for surveillance imaging. • CT accounted for 98.3 % of CED in patients with testicular cancer. • Median CED in patients with testicular cancer was 125.1 mSv • High CED (>75 mSv) was observed in 77.5 % (93/120) of patients. • Dose tracking and development of low-dose CT protocols are recommended.
Radiologic methods of evaluating generalized osteopenia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schneider, R.
1984-10-01
Noninvasive methods of evaluating generalized osteopenia include radiography, radionuclide studies, and various quantitative studies. These methods differ in availability, cost, accuracy, precision, radiation dose, and information supplied about bony change. A combination of methods is necessary to detect and follow the course and treatment of osteopenia.
10 CFR 963.16 - Postclosure suitability evaluation method.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 963.16 Energy DEPARTMENT OF ENERGY YUCCA MOUNTAIN SITE SUITABILITY GUIDELINES Site Suitability... assessment to evaluate the ability of the Yucca Mountain disposal system to limit radiological doses and... the performance of the Yucca Mountain disposal system using the method described in paragraph (b) of...
Radiological dosimetry measurements in Costa Rica
DOE Office of Scientific and Technical Information (OSTI.GOV)
León, M., E-mail: mauisoiso@gmail.com; Santos, F., E-mail: fsantosg@gmail.com
The main cause of human exposure to artificial radiation corresponds to medical applications, so it is essential to reduce the dose to patients, workers and consequently the entire population [1]. Although there is no dose limit for patients, is necessary to reduce it to a minimum possible while still getting all the necessary diagnostic information, taking economic and social factors into account [2]. Based on this proposal, agencies such as the International Atomic Energy Agency has been dedicated to providing guidelines levels, whose function is to serve as standards for the optimization of the medical exposure [3]. This research wasmore » created as a preliminary survey with the claim of eventually determine the guidance levels in Costa Rica for three different studies of general radiology: Lumbar Spine-AP, Chest - PA and Thoracic Spine - AP (for screens with speeds of 400 and 800), and cranio-caudal study in mammography, applied to Costa Rica’s adult population, perform properly in the institutions of Caja Costarricense del Seguro Social (CCSS).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erickson, Beth A.; Demanes, D. Jeffrey; Ibbott, Geoffrey S.
2011-03-01
High-Dose-Rate (HDR) brachytherapy is a safe and efficacious treatment option for patients with a variety of different malignancies. Careful adherence to established standards has been shown to improve the likelihood of procedural success and reduce the incidence of treatment-related morbidity. A collaborative effort of the American College of Radiology (ACR) and American Society for Therapeutic Radiation Oncology (ASTRO) has produced a practice guideline for HDR brachytherapy. The guideline defines the qualifications and responsibilities of all the involved personnel, including the radiation oncologist, physicist and dosimetrists. Review of the leading indications for HDR brachytherapy in the management of gynecologic, thoracic, gastrointestinal,more » breast, urologic, head and neck, and soft tissue tumors is presented. Logistics with respect to the brachytherapy implant procedures and attention to radiation safety procedures and documentation are presented. Adherence to these practice guidelines can be part of ensuring quality and safety in a successful HDR brachytherapy program.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-04-01
This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant (BFN) in 1992. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiationmore » levels. Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. Small amounts of Co-60 and Cs-134 were found in sediment samples downstream from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public.« less
Radiological dosimetry measurements in Costa Rica
NASA Astrophysics Data System (ADS)
León, M.; Santos, F.
2016-07-01
The main cause of human exposure to artificial radiation corresponds to medical applications, so it is essential to reduce the dose to patients, workers and consequently the entire population [1]. Although there is no dose limit for patients, is necessary to reduce it to a minimum possible while still getting all the necessary diagnostic information, taking economic and social factors into account [2]. Based on this proposal, agencies such as the International Atomic Energy Agency has been dedicated to providing guidelines levels, whose function is to serve as standards for the optimization of the medical exposure [3]. This research was created as a preliminary survey with the claim of eventually determine the guidance levels in Costa Rica for three different studies of general radiology: Lumbar Spine-AP, Chest - PA and Thoracic Spine - AP (for screens with speeds of 400 and 800), and cranio-caudal study in mammography, applied to Costa Rica's adult population, perform properly in the institutions of Caja Costarricense del Seguro Social (CCSS).
NASA Astrophysics Data System (ADS)
Ingale, S. V.; Datta, D.
2010-10-01
Consequence of the accidental release of radioactivity from a nuclear power plant is assessed in terms of exposure or dose to the members of the public. Assessment of risk is routed through this dose computation. Dose computation basically depends on the basic dose assessment model and exposure pathways. One of the exposure pathways is the ingestion of contaminated food. The aim of the present paper is to compute the uncertainty associated with the risk to the members of the public due to the ingestion of contaminated food. The governing parameters of the ingestion dose assessment model being imprecise, we have approached evidence theory to compute the bound of the risk. The uncertainty is addressed by the belief and plausibility fuzzy measures.
Medical physics: some recollections in diagnostic X-ray imaging and therapeutic radiology.
Gray, J E; Orton, C G
2000-12-01
Medical physics has changed dramatically since 1895. There was a period of slow evolutionary change during the first 70 years after Roentgen's discovery of x rays. With the advent of the computer, however, both diagnostic and therapeutic radiology have undergone rapid growth and changes. Technologic advances such as computed tomography and magnetic resonance imaging in diagnostic imaging and three-dimensional treatment planning systems, stereotactic radiosurgery, and intensity modulated radiation therapy in radiation oncology have resulted in substantial changes in medical physics. These advances have improved diagnostic imaging and radiation therapy while expanding the need for better educated and experienced medical physics staff.
Bahari, Ismail; Mohsen, Nasirian; Abdullah, Pauzi
2007-01-01
The processing of amang, or tin tailings, for valuable minerals has been shown to technologically enhance NORM and this has stirred significant radiological safety and health concerns among Malaysia's regulatory authority. A growing radiological concern is now focused on the amang effluent containing NORM in recycling ponds, since these ponds may be reclaimed for future residential developments. A study was carried out to assess the radiological risk associated with amang processing and the accumulated effluent in the recycling ponds. Twenty-six sediment samples from the recycling ponds of two amang plants in the states of Selangor and Perak, Malaysia, were collected and analyzed. The maximum activity concentrations of (238)U, (226)Ra, (232)Th and (40)K recorded in sediments from these ponds were higher than Malaysia's and the world's natural highest. Correspondingly, the mean radium equivalent activity concentration indices, Ra(eq), and gamma radiation representative level index, I(gammar), were higher than the world's average. The enhancement of NORM in effluent sediments as a consequence of amang processing, and the use of a closed water management recycling system created Effective Dose Rates, E (nSv h(-1)), that signal potential environmental radiological risks in these ponds, should they be reclaimed for future land use.