Sample records for radiological performance objectives

  1. Educational treasures in radiology: a free online program for Radiology Boards preparation.

    PubMed

    Talanow, Roland

    2011-01-01

    An objective tool is desired, which optimally prepares for Radiology boards examination. Such program should prepare examinees with pertinent radiological contents and simulations as expected in the real examination. Many countries require written boards examinations for Radiology certification eligibility. No objective measure exists to tell if the examinee is ready to pass the exam or not. Time pressure and computer environment might be unfamiliar to examinees. Traditional preparation lectures don't simulate the "real" Radiology exam because they don't provide the special environment with multiple choice questions and timing. This online program consists of 4 parts. The entry section allows to create questions with additional fields for comprehensive information. Sections include Pediatrics/Mammography/GI/IR/Nucs/Thoracic/Musculoskeletal/GU/Neuro/Ultrasound/Cardiac/OB/GYN and Miscellaneous. Experienced radiologists and educators evaluate and release/delete these entries in the administrator section. In the exam section users can create (un)timed customized exams for individual needs and learning pace. Exams can either include all sections or only specific sections to gear learning towards areas with weaker performance. Comprehensive statistics unveil the user's strengths and weaknesses to help focussing on "weak" areas. In the search section a comprehensive search and review can be performed by searching the entire database for keywords/topics or only searching within specific sections. www.RadiologyBoards.org is a new working concept of Radiology boards preparation to detect and improve the examinee's weaknesses and finally to increase the examinee's confidence level for the final exam. It is beneficial for Radiology residents and also board certified radiologists to refresh/maintain radiological knowledge.

  2. Curriculum Development and Alignment in Radiologic Technology.

    ERIC Educational Resources Information Center

    Dowd, Steven B.

    Before developing a curriculum for radiologic technology, one must first attempt to define the term "curriculum." The term is not easy to define precisely, although it does imply the necessity of a master plan that outlines institutional philosophy and goals, course descriptions, description of competency-based evaluation, performance objectives,…

  3. Virtual management of radiology examinations in the virtual radiology environment using common object request broker architecture services.

    PubMed

    Martinez, R; Rozenblit, J; Cook, J F; Chacko, A K; Timboe, H L

    1999-05-01

    In the Department of Defense (DoD), US Army Medical Command is now embarking on an extremely exciting new project--creating a virtual radiology environment (VRE) for the management of radiology examinations. The business of radiology in the military is therefore being reengineered on several fronts by the VRE Project. In the VRE Project, a set of intelligent agent algorithms determine where examinations are to routed for reading bases on a knowledge base of the entire VRE. The set of algorithms, called the Meta-Manager, is hierarchical and uses object-based communications between medical treatment facilities (MTFs) and medical centers that have digital imaging network picture archiving and communications systems (DIN-PACS) networks. The communications is based on use of common object request broker architecture (CORBA) objects and services to send patient demographics and examination images from DIN-PACS networks in the MTFs to the DIN-PACS networks at the medical centers for diagnosis. The Meta-Manager is also responsible for updating the diagnosis at the originating MTF. CORBA services are used to perform secure message communications between DIN-PACS nodes in the VRE network. The Meta-Manager has a fail-safe architecture that allows the master Meta-Manager function to float to regional Meta-Manager sites in case of server failure. A prototype of the CORBA-based Meta-Manager is being developed by the University of Arizona's Computer Engineering Research Laboratory using the unified modeling language (UML) as a design tool. The prototype will implement the main functions described in the Meta-Manager design specification. The results of this project are expected to reengineer the process of radiology in the military and have extensions to commercial radiology environments.

  4. Integrated Fellowship in Vascular Surgery and Intervention Radiology

    PubMed Central

    Messina, Louis M.; Schneider, Darren B.; Chuter, Timothy A. M.; Reilly, Linda M.; Kerlan, Robert K.; LaBerge, Jeane M.; Wilson, Mark W.; Ring, Ernest J.; Gordon, Roy L.

    2002-01-01

    Objective To evaluate an integrated fellowship in vascular surgery and interventional radiology initiated to train vascular surgeons in endovascular techniques and to train radiology fellows in clinical aspects of vascular diseases. Summary Background Data The rapid evolution of endovascular techniques for the treatment of vascular diseases requires that vascular surgeons develop proficiency in these techniques and that interventional radiologists develop proficiency in the clinical evaluation and management of patients who are best treated with endovascular techniques. In response to this need the authors initiated an integrated fellowship in vascular surgery and interventional radiology and now report their interim results. Methods Since 1999 vascular fellows and radiology fellows performed an identical year-long fellowship in interventional radiology. During the fellowship, vascular surgery and radiology fellows perform both vascular and nonvascular interventional procedures. Both vascular surgery and radiology-based fellows spend one quarter of the year on the vascular service performing endovascular aortic aneurysm repairs and acquiring clinical experience in the vascular surgery inpatient and outpatient services. Vascular surgery fellows then complete an additional year-long fellowship in vascular surgery. To evaluate the type and number of interventional radiology procedures, the authors analyzed records of cases performed by all interventional radiology and vascular surgery fellows from a prospectively maintained database. The attitudes of vascular surgery and interventional radiology faculty and fellows toward the integrated fellowship were surveyed using a formal questionnaire. Results During the fellowship each fellow performed an average of 1,201 procedures, including 808 vascular procedures (236 diagnostic angiograms, 70 arterial interventions, 59 diagnostic venograms, 475 venous interventions, and 43 hemodialysis graft interventions) and 393 nonvascular procedures. On average fellows performed 20 endovascular aortic aneurysm repairs per year. There was no significant difference between the vascular surgery and radiology fellows in either the spectrum or number of cases performed. Eighty-eight percent (23/26) of the questionnaires were completed and returned. Both interventional radiologists and vascular surgeons strongly supported the integrated fellowship model and favored continuation of the integrated program. Vascular surgery and interventional radiology faculty members wanted additional training in clinical vascular surgery for the radiology-based fellows. With the exception of the radiology fellows there was uniform agreement that vascular surgery fellows benefit from training in nonvascular aspects of interventional radiology. Conclusions Integration of vascular surgery and interventional radiology fellowships is feasible and is mutually beneficial to both disciplines. Furthermore, the integrated fellowship provides exceptional training for vascular surgery and interventional radiology fellows in all catheter-based techniques that far exceeds the minimum requirements for credentialing suggested by various professional societies. There is a clear need for cooperation and active involvement on the parts of the American Board of Radiology and the American Board of Surgery and its Vascular Board to create hybrid training programs that meet mutually agreed-on criteria that document sufficient acquisition of both the cognitive and technical skills required to manage patients undergoing endovascular procedures safely and effectively. PMID:12368668

  5. A reference standard-based quality assurance program for radiology.

    PubMed

    Liu, Patrick T; Johnson, C Daniel; Miranda, Rafael; Patel, Maitray D; Phillips, Carrie J

    2010-01-01

    The authors have developed a comprehensive radiology quality assurance (QA) program that evaluates radiology interpretations and procedures by comparing them with reference standards. Performance metrics are calculated and then compared with benchmarks or goals on the basis of published multicenter data and meta-analyses. Additional workload for physicians is kept to a minimum by having trained allied health staff members perform the comparisons of radiology reports with the reference standards. The performance metrics tracked by the QA program include the accuracy of CT colonography for detecting polyps, the false-negative rate for mammographic detection of breast cancer, the accuracy of CT angiography detection of coronary artery stenosis, the accuracy of meniscal tear detection on MRI, the accuracy of carotid artery stenosis detection on MR angiography, the accuracy of parathyroid adenoma detection by parathyroid scintigraphy, the success rate for obtaining cortical tissue on ultrasound-guided core biopsies of pelvic renal transplants, and the technical success rate for peripheral arterial angioplasty procedures. In contrast with peer-review programs, this reference standard-based QA program minimizes the possibilities of reviewer bias and erroneous second reviewer interpretations. The more objective assessment of performance afforded by the QA program will provide data that can easily be used for education and management conferences, research projects, and multicenter evaluations. Additionally, such performance data could be used by radiology departments to demonstrate their value over nonradiology competitors to referring clinicians, hospitals, patients, and third-party payers. Copyright 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  6. Radiology Undergraduate and Resident Curricula: A Narrative Review of the Literature

    PubMed Central

    Linaker, Kathleen L.

    2015-01-01

    Objective The purpose of this study was to examine the literature regarding radiology curricula for both undergraduates and residents. Methods A review of the literature was performed using relevant key words. Articles were retrieved through December 2012 using PubMed, ScienceDirect, ERIC, Proquest, and ICL databases along with a manual review of references. Results Of the 4716 unique abstracts reviewed by the author, 142 were found to be relevant to the purpose of this study. Undergraduate radiology education, radiology curriculum, and radiology pedagogy vary widely between disciplines and between colleges within disciplines. Formal radiology education is not taught at all medical programs and little radiology training is incorporated into non-radiology residencies. This results in some medical graduates not being taught how to interpret basic radiology images and not learning contraindications and indications for ordering diagnostic imaging tests. There are no definitive studies examining how to incorporate radiology into the curriculum, how to teach radiology to either undergraduates or residents, or how to assess this clinical competency. Conclusions This review shows that radiology education is perceived to be important in undergraduate and residency programs. However, some programs do not include radiology training, thus graduates from those programs do not learn radiology essentials. PMID:26770172

  7. Physical and cognitive task analysis in interventional radiology.

    PubMed

    Johnson, S; Healey, A; Evans, J; Murphy, M; Crawshaw, M; Gould, D

    2006-01-01

    To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model.

  8. Efficient radiologic reading environment by using an open-source macro program as connection software.

    PubMed

    Lee, Young Han

    2012-01-01

    The objectives are (1) to introduce an easy open-source macro program as connection software and (2) to illustrate the practical usages in radiologic reading environment by simulating the radiologic reading process. The simulation is a set of radiologic reading process to do a practical task in the radiologic reading room. The principal processes are: (1) to view radiologic images on the Picture Archiving and Communicating System (PACS), (2) to connect the HIS/EMR (Hospital Information System/Electronic Medical Record) system, (3) to make an automatic radiologic reporting system, and (4) to record and recall information of interesting cases. This simulation environment was designed by using open-source macro program as connection software. The simulation performed well on the Window-based PACS workstation. Radiologists practiced the steps of the simulation comfortably by utilizing the macro-powered radiologic environment. This macro program could automate several manual cumbersome steps in the radiologic reading process. This program successfully acts as connection software for the PACS software, EMR/HIS, spreadsheet, and other various input devices in the radiologic reading environment. A user-friendly efficient radiologic reading environment could be established by utilizing open-source macro program as connection software. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  9. Potential clinical impact of advanced imaging and computer-aided diagnosis in chest radiology: importance of radiologist's role and successful observer study.

    PubMed

    Li, Feng

    2015-07-01

    This review paper is based on our research experience in the past 30 years. The importance of radiologists' role is discussed in the development or evaluation of new medical images and of computer-aided detection (CAD) schemes in chest radiology. The four main topics include (1) introducing what diseases can be included in a research database for different imaging techniques or CAD systems and what imaging database can be built by radiologists, (2) understanding how radiologists' subjective judgment can be combined with technical objective features to improve CAD performance, (3) sharing our experience in the design of successful observer performance studies, and (4) finally, discussing whether the new images and CAD systems can improve radiologists' diagnostic ability in chest radiology. In conclusion, advanced imaging techniques and detection/classification of CAD systems have a potential clinical impact on improvement of radiologists' diagnostic ability, for both the detection and the differential diagnosis of various lung diseases, in chest radiology.

  10. A novel quality assurance method in a university teaching paediatric radiology department.

    PubMed

    Gallet, J M; Reed, M H; Hlady, J

    2000-08-01

    Primary diagnostic equipment in a paediatric radiology department must perform at optimal levels at all times. The Children's Hospital Radiology Department in Winnipeg, Canada, has developed an impartial means of reporting radiographic image quality. The main objectives of this study programme were two-fold. First, to monitor diagnostic X-ray equipment performance, and second, to improve the resultant image quality as a means of implementing the fundamental concepts of continuous quality improvement. Reading radiologists completed a quality assurance (QA) card when they identified a radiographic image quality problem. The cards were subsequently collected by the clinical instructor who then informed, in confidence, the radiographers of the written comments or concerns. QA cards have been conspicuously installed in the paediatric radiology reading room since the middle of 1993. Since its inception, equipment malfunction has been monitored and indicators for improving image quality developed. This component of the QA programme has shown itself to be a successful means of communicating with radiographers in maintaining superior image quality.

  11. Radiation dose from common radiological investigations and cumulative exposure in children with cystic fibrosis: an observational study from a single UK centre

    PubMed Central

    Ward, Rebecca; Carroll, William D; Cunningham, Paula; Ho, Sheng-Ang; Jones, Mary; Lenney, Warren; Thompson, David

    2017-01-01

    Objectives Cumulative radiation exposure is associated with increased risk of malignancy. This is important in cystic fibrosis (CF) as frequent imaging is required to monitor disease progression and diagnose complications. Previous estimates of cumulative radiation are outdated as the imaging was performed on older equipment likely to deliver higher radiation. Our objectives were to determine the radiation dose delivered to children during common radiological investigations using modern equipment and to identify the number of such investigations performed in a cohort of children with CF to calculate their cumulative radiation exposure. Design, setting and participants Data including age at investigation and radiation exposure measured as estimated effective dose (EED) were collected on 2827 radiological studies performed on children at one UK paediatric centre. These were combined with the details of all radiological investigations performed on 65 children with CF attending the same centre to enable calculation of each child’s cumulative radiation exposure. Results The mean EED for the common radiological investigations varied according to age. The range was 0.01–0.02 mSv for chest X-rays, 0.03–0.11 mSv for abdominal X-rays, 0.57–1.69 mSv for CT chest, 2.9–3.9 mSv for abdominal and pelvic CT, 0.20–0.21 mSv for sinus CT and 0.15–0.52 mSv for fluoroscopy-guided procedures. The mean EED was three to five times higher for helical compared with axial chest CT scans. The mean annual cumulative EED for our cohort of children with CF was 0.15 mSv/year with an estimated cumulative paediatric lifetime EED (0–18 years) of 3.5 mSv. Conclusions This study provides up-to-date estimations of the radiation exposure when using common radiological investigations. These doses and the estimates of cumulative radiation exposure in children with CF are lower than previously reported. This reflects the reduced EED associated with modern equipment and the use of age-specific scanning protocols. PMID:28827272

  12. Accountable care organizations and radiology: threat or opportunity?

    PubMed

    Abramson, Richard G; Berger, Paul E; Brant-Zawadzki, Michael N

    2012-12-01

    Although the anticipated rise of accountable care organizations brings certain potential threats to radiologists, including direct threats to revenue and indirect systemic changes jeopardizing the bargaining leverage of radiology groups, accountable care organizations, and other integrated health care delivery models may provide radiology with an important opportunity to reassert its leadership and assume a more central role within health care systems. Capitalizing on this potential opportunity, however, will require radiology groups to abandon the traditional "film reader" mentality and engage actively in the design and implementation of nontraditional systems service lines aimed at adding differentiated value to larger health care organizations. Important interlinked and mutually reinforcing components of systems service lines, derived from radiology's core competencies, may include utilization management and decision support, IT leadership, quality and safety assurance, and operational enhancements to meet organizational goals. Such systems-oriented service products, tailored to the needs of individual integrated care entities and supported by objective performance metrics, may provide market differentiation to shield radiology from commoditization and could become an important source of new nonclinical revenue. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Key Performance Indicators in the Evaluation of the Quality of Radiation Safety Programs.

    PubMed

    Schultz, Cheryl Culver; Shaffer, Sheila; Fink-Bennett, Darlene; Winokur, Kay

    2016-08-01

    Beaumont is a multiple hospital health care system with a centralized radiation safety department. The health system operates under a broad scope Nuclear Regulatory Commission license but also maintains several other limited use NRC licenses in off-site facilities and clinics. The hospital-based program is expansive including diagnostic radiology and nuclear medicine (molecular imaging), interventional radiology, a comprehensive cardiovascular program, multiple forms of radiation therapy (low dose rate brachytherapy, high dose rate brachytherapy, external beam radiotherapy, and gamma knife), and the Research Institute (including basic bench top, human and animal). Each year, in the annual report, data is analyzed and then tracked and trended. While any summary report will, by nature, include items such as the number of pieces of equipment, inspections performed, staff monitored and educated and other similar parameters, not all include an objective review of the quality and effectiveness of the program. Through objective numerical data Beaumont adopted seven key performance indicators. The assertion made is that key performance indicators can be used to establish benchmarks for evaluation and comparison of the effectiveness and quality of radiation safety programs. Based on over a decade of data collection, and adoption of key performance indicators, this paper demonstrates one way to establish objective benchmarking for radiation safety programs in the health care environment.

  14. Collaborative Radiological Response Planning

    DTIC Science & Technology

    2013-12-01

    280-5500 Standard Form 298 (Rev. 2–89) Prescribed by ANSI Std. 239–18 i THIS PAGE INTENTIONALLY LEFT BLANK ii Approved for public release...critical tasks, under specified conditions and performance standards .”33 Aligned with the central objective of Capabilities-Based Planning, the TCL...affect task performance.36 More specifically, measures and performance criteria describe a standard for how well a task must be performed and on

  15. Care and economic impact of thyroid ultrasound examination at single visits to endocrinology clinics (the ETIEN 1 study).

    PubMed

    Carral, Florentino; Ayala, María del Carmen; Jiménez, Ana Isabel; García, Concepción

    2016-02-01

    Routine thyroid ultrasound examination in a single medical appointment is rarely performed in Spain. The objective of this study was to evaluate the care and economic impact of thyroid US examination in a single endocrine appointment. A prospective, observational, descriptive study was conducted to analyze data from 2274 patients (mean age, 59±16 years; 83% females) performed at least one thyroid US in a single visit to an endocrinology clinic during 2013 and 2014. The number of endocrine acts with thyroid US, single endocrine and US acts without review, and the change in the number of thyroid US requested by endocrinologists to the radiology department and total thyroid US examinations performed at the radiology department during the study period were assessed. In 2013 and 2014, 2558 endocrine acts with thyroid US were performed, of which 42.2% were single endocrine and US appointments without a second endocrine act, with estimated savings of €58,946.40. As compared to 2012, the number of thyroid US requested by endocrinologists to the radiology department decreased by 43.3% and 86.0% in 2013 and 2014 respectively, and total thyroid US performed by the radiology department decreased by 28.1% and 68.3% respectively, with estimated savings of €94,441.36. Thyroid US examination in a single endocrine appointment allows for decreasing the number of both second endocrine acts and thyroid US examinations performed at the radiology department, thus reducing the number of unnecessary clinic visits and promoting considerable economic savings. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  16. A portrait of interventional radiologists in the United States.

    PubMed

    Sunshine, Jonathan H; Lewis, Rebecca S; Bhargavan, Mythreyi

    2005-11-01

    In recognition of the emergence of interventional radiology as an important "new component of...radiology," the objective of our study was to provide an extensive and detailed portrait of interventional radiologists, their professional activities, and the practices in which they work. We tabulated data from the American College of Radiology's 2003 Survey of Radiologists, a stratified random-sample survey that oversampled interventionalists and achieved a 63% response rate with a total of 1,924 responses. Responses were weighted to make them representative of all radiologists in the United States. We compared information about interventionalists with that for other radiologists. Depending on the definition of who is an interventionalist, 8.5-11.5% of radiologists are interventionalists. By most definitions, only slightly under half of interventionalists spend 70% or more of their clinical work time performing interventional procedures. Interventionalists work, on average, 56-58 hr weekly, a few hours longer than other radiologists. The average interventionalist performs procedures in five of the seven categories of procedures into which we divided interventional radiology, compared with one or two categories for other radiologists. The average interventionalist performs procedures in five of the seven broad categories (such as MRI, CT, and nuclear medicine) into which we divided all of radiology, much the same breadth of practice as other subspecialists and also as nonsubspecialists. Interventionalists have become a sizable group within radiology. They are in some ways like other radiologists and in other ways different, but they do not spend as much of their time in their subspecialty as some assume and, overall, are not as different.

  17. Effective radiology dashboards: key research findings.

    PubMed

    Karami, Mahtab; Safdari, Reza; Rahimi, Azin

    2013-01-01

    Innovative organizations have access to information for business intelligence through the objectives displayed in dashboards. In healthcare organizations, where the goal is to improve quality of care along with reducing costs, the radiology department is important from both financial and clinical aspects. Therefore, how to manage this department has critical impact on the effectiveness and efficiency of the organization. Today, since the information in this department not only has different data structure but also is gathered from different data sources, a well defined, comprehensive dashboard can be an effective tool to enhance performance.

  18. Material Identification Algorithm

    DTIC Science & Technology

    2007-09-01

    realistic scenes composed of uneven ground, trees, and reflecting objects. The simulation includes effects of ionospheric dispersion on the radar pulses...effects of ionospheric dispersion on the SAR returns. Summary - Part 1I The objective of this effort was to perform numerical simulations for large...study," Radiology, vol. 216, pp. 279-283, 2000. [9] M. Xu, G. Ku, and L. V. Wang, "Microwave-induced thermoacous- tic tomography using multi-sector

  19. Addressing the coming radiology crisis-the Society for Computer Applications in Radiology transforming the radiological interpretation process (TRIP) initiative.

    PubMed

    Andriole, Katherine P; Morin, Richard L; Arenson, Ronald L; Carrino, John A; Erickson, Bradley J; Horii, Steven C; Piraino, David W; Reiner, Bruce I; Seibert, J Anthony; Siegel, Eliot

    2004-12-01

    The Society for Computer Applications in Radiology (SCAR) Transforming the Radiological Interpretation Process (TRIP) Initiative aims to spearhead research, education, and discovery of innovative solutions to address the problem of information and image data overload. The initiative will foster interdisciplinary research on technological, environmental and human factors to better manage and exploit the massive amounts of data. TRIP will focus on the following basic objectives: improving the efficiency of interpretation of large data sets, improving the timeliness and effectiveness of communication, and decreasing medical errors. The ultimate goal of the initiative is to improve the quality and safety of patient care. Interdisciplinary research into several broad areas will be necessary to make progress in managing the ever-increasing volume of data. The six concepts involved are human perception, image processing and computer-aided detection (CAD), visualization, navigation and usability, databases and integration, and evaluation and validation of methods and performance. The result of this transformation will affect several key processes in radiology, including image interpretation; communication of imaging results; workflow and efficiency within the health care enterprise; diagnostic accuracy and a reduction in medical errors; and, ultimately, the overall quality of care.

  20. Emergency imaging after a mass casualty incident: role of the radiology department during training for and activation of a disaster management plan

    PubMed Central

    Körner, Markus; Bernstein, Mark P; Sodickson, Aaron D; Beenen, Ludo F; McLaughlin, Patrick D; Kool, Digna R; Bilow, Ronald M

    2016-01-01

    In the setting of mass casualty incidents (MCIs), hospitals need to divert from normal routine to delivering the best possible care to the largest number of victims. This should be accomplished by activating an established hospital disaster management plan (DMP) known to all staff through prior training drills. Over the recent decades, imaging has increasingly been used to evaluate critically ill patients. It can also be used to increase the accuracy of triaging MCI victims, since overtriage (falsely higher triage category) and undertriage (falsely lower triage category) can severely impact resource availability and mortality rates, respectively. This article emphasizes the importance of including the radiology department in hospital preparations for a MCI and highlights factors expected to influence performance during hospital DMP activation including issues pertinent to effective simulation, such as establishing proper learning objectives. After-action reviews including performance evaluation and debriefing on issues are invaluable following simulation drills and DMP activation, in order to improve subsequent preparedness. Historically, most hospital DMPs have not adequately included radiology department operations, and they have not or to a little extent been integrated in the DMP activation simulation. This article aims to increase awareness of the need for radiology department engagement in order to increase radiology department preparedness for DMP activation after a MCI occurs. PMID:26781837

  1. Experimental Design and Data Analysis in Receiver Operating Characteristic Studies: Lessons Learned from Reports in Radiology from 1997 to 20061

    PubMed Central

    Shiraishi, Junji; Pesce, Lorenzo L.; Metz, Charles E.; Doi, Kunio

    2009-01-01

    Purpose: To provide a broad perspective concerning the recent use of receiver operating characteristic (ROC) analysis in medical imaging by reviewing ROC studies published in Radiology between 1997 and 2006 for experimental design, imaging modality, medical condition, and ROC paradigm. Materials and Methods: Two hundred ninety-five studies were obtained by conducting a literature search with PubMed with two criteria: publication in Radiology between 1997 and 2006 and occurrence of the phrase “receiver operating characteristic.” Studies returned by the query that were not diagnostic imaging procedure performance evaluations were excluded. Characteristics of the remaining studies were tabulated. Results: Two hundred thirty-three (79.0%) of the 295 studies reported findings based on observers' diagnostic judgments or objective measurements. Forty-three (14.6%) did not include human observers, with most of these reporting an evaluation of a computer-aided diagnosis system or functional data obtained with computed tomography (CT) or magnetic resonance (MR) imaging. The remaining 19 (6.4%) studies were classified as reviews or meta-analyses and were excluded from our subsequent analysis. Among the various imaging modalities, MR imaging (46.0%) and CT (25.7%) were investigated most frequently. Approximately 60% (144 of 233) of ROC studies with human observers published in Radiology included three or fewer observers. Conclusion: ROC analysis is widely used in radiologic research, confirming its fundamental role in assessing diagnostic performance. However, the ROC studies reported in Radiology were not always adequate to support clear and clinically relevant conclusions. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533081632/-/DC1 PMID:19864510

  2. Remedial training for the radiology resident: a template for optimization of the learning plan.

    PubMed

    Mar, Colin; Chang, Silvia; Forster, Bruce

    2015-02-01

    All radiology residency programs should strive for the early identification of individuals in need of remedial training and have an approach ready to address this situation. This article provides a template for a step-by-step approach which is team based. It includes definition of the learning or performance issues, creation of suitable learning objectives and learning plan, facilitation of feedback and assessment, and definition of outcomes. Using such a template will assist the resident in returning to the path toward a safe and competent radiologist. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  3. Radiologic discrepancies in children with special healthcare needs in a pediatric emergency department.

    PubMed

    Festekjian, Ara; Kwan, Karen Y; Chang, Todd P; Lai, Hollie; Fahit, Margil; Liberman, Danica B

    2017-12-21

    After-hours radiologic interpretation by nonradiology attendings or resident radiologists introduces the risk of discrepancies. Clinical outcomes following radiologic discrepancies among pediatric emergency department (ED) patients are poorly described. In particular, children with special healthcare needs (CSHCN), have more opportunities for discrepancies and potential consequences than non- CSHCN. Our objective was to determine the rates and types of radiologic discrepancies, and to compare CSHCN to non-CSHCN. From July 2014 to February 2015, all children who underwent a diagnostic imaging study at a free-standing children's ED were included. Data collected included radiologic studies - type and location - and clinical details - chief complaint and CSHCN type. Differences between preliminary reads and final pediatric radiology attending reads were defined as discrepancies, and categorized by clinical significance. Descriptive statistics, z-tests, and chi-square were used. Over 8months, 8310 visits (7462 unique patients) had radiologic studies (2620 CSHCN, 5690 non-CSHCN). A total of 198 (2.4%) radiologic discrepancies [56 (28.3%) CSHCN, 142 (71.7%) non-CSHCN] were found. Chief complaints for CSCHN were more often within the cardiac, pulmonary and neurologic systems (p<0.001 for each), whereas non-CSHCN presented with more trauma (p<0.001). The rates of discrepancies (CSHCN 2.1%, non- CSHCN 2.5%, p=0.3) and severity of clinical consequences (p=0.6) were not significantly different between CSHCN and non-CSHCN. Though the frequency and type of radiologic studies performed between CSHCN and non-CSHCN were different, we found no significant difference in the rate of radiologic discrepancies or the rate of clinically significant radiologic discrepancies. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. ISSLS PRIZE IN BIOENGINEERING SCIENCE 2017: Automation of reading of radiological features from magnetic resonance images (MRIs) of the lumbar spine without human intervention is comparable with an expert radiologist.

    PubMed

    Jamaludin, Amir; Lootus, Meelis; Kadir, Timor; Zisserman, Andrew; Urban, Jill; Battié, Michele C; Fairbank, Jeremy; McCall, Iain

    2017-05-01

    Investigation of the automation of radiological features from magnetic resonance images (MRIs) of the lumbar spine. To automate the process of grading lumbar intervertebral discs and vertebral bodies from MRIs. MR imaging is the most common imaging technique used in investigating low back pain (LBP). Various features of degradation, based on MRIs, are commonly recorded and graded, e.g., Modic change and Pfirrmann grading of intervertebral discs. Consistent scoring and grading is important for developing robust clinical systems and research. Automation facilitates this consistency and reduces the time of radiological analysis considerably and hence the expense. 12,018 intervertebral discs, from 2009 patients, were graded by a radiologist and were then used to train: (1) a system to detect and label vertebrae and discs in a given scan, and (2) a convolutional neural network (CNN) model that predicts several radiological gradings. The performance of the model, in terms of class average accuracy, was compared with the intra-observer class average accuracy of the radiologist. The detection system achieved 95.6% accuracy in terms of disc detection and labeling. The model is able to produce predictions of multiple pathological gradings that consistently matched those of the radiologist. The model identifies 'Evidence Hotspots' that are the voxels that most contribute to the degradation scores. Automation of radiological grading is now on par with human performance. The system can be beneficial in aiding clinical diagnoses in terms of objectivity of gradings and the speed of analysis. It can also draw the attention of a radiologist to regions of degradation. This objectivity and speed is an important stepping stone in the investigation of the relationship between MRIs and clinical diagnoses of back pain in large cohorts. Level 3.

  5. Oblique Chest Views as a Routine Part of Skeletal Surveys Performed for Possible Physical Abuse--Is This Practice Worthwhile?

    ERIC Educational Resources Information Center

    Hansen, Karen Kirhofer; Prince, Jeffrey S.; Nixon, G. William

    2008-01-01

    Objective: To evaluate the utility of oblique chest views in the diagnosis of rib fractures when used as a routine part of the skeletal survey performed for possible physical abuse. Methods: Oblique chest views have been part of the routine skeletal survey protocol at Primary Children's Medical Center since October 2002. Dictated radiology reports…

  6. Bibliometric Analysis of Manuscript Characteristics That Influence Citations: A Comparison of Six Major Radiology Journals.

    PubMed

    Shekhani, Haris Naseem; Shariff, Shoaib; Bhulani, Nizar; Khosa, Faisal; Hanna, Tarek Noel

    2017-12-01

    The objective of our study was to investigate radiology manuscript characteristics that influence citation rate, capturing features of manuscript construction that are discrete from study design. Consecutive articles published from January 2004 to June 2004 were collected from the six major radiology journals with the highest impact factors: Radiology (impact factor, 5.076), Investigative Radiology (2.320), American Journal of Neuroradiology (AJNR) (2.384), RadioGraphics (2.494), European Radiology (2.364), and American Journal of Roentgenology (2.406). The citation count for these articles was retrieved from the Web of Science, and 29 article characteristics were tabulated manually. A point-biserial correlation, Spearman rank-order correlation, and multiple regression model were performed to predict citation number from the collected variables. A total of 703 articles-211 published in Radiology, 48 in Investigative Radiology, 106 in AJNR, 52 in RadioGraphics, 129 in European Radiology, and 157 in AJR-were evaluated. Punctuation was included in the title in 55% of the articles and had the highest statistically significant positive correlation to citation rate (point-biserial correlation coefficient [r pb ] = 0.85, p < 0.05). Open access status provided a low-magnitude, but significant, correlation to citation rate (r pb = 0.140, p < 0.001). The following variables created a significant multiple regression model to predict citation count (p < 0.005, R 2 = 0.186): study findings in the title, abstract word count, abstract character count, total number of words, country of origin, and all authors in the field of radiology. Using bibliometric knowledge, authors can craft a title, abstract, and text that may enhance visibility and citation count over what they would otherwise experience.

  7. Improved Identification of Noun Phrases in Clinical Radiology Reports Using a High-Performance Statistical Natural Language Parser Augmented with the UMLS Specialist Lexicon

    PubMed Central

    Huang, Yang; Lowe, Henry J.; Klein, Dan; Cucina, Russell J.

    2005-01-01

    Objective: The aim of this study was to develop and evaluate a method of extracting noun phrases with full phrase structures from a set of clinical radiology reports using natural language processing (NLP) and to investigate the effects of using the UMLS® Specialist Lexicon to improve noun phrase identification within clinical radiology documents. Design: The noun phrase identification (NPI) module is composed of a sentence boundary detector, a statistical natural language parser trained on a nonmedical domain, and a noun phrase (NP) tagger. The NPI module processed a set of 100 XML-represented clinical radiology reports in Health Level 7 (HL7)® Clinical Document Architecture (CDA)–compatible format. Computed output was compared with manual markups made by four physicians and one author for maximal (longest) NP and those made by one author for base (simple) NP, respectively. An extended lexicon of biomedical terms was created from the UMLS Specialist Lexicon and used to improve NPI performance. Results: The test set was 50 randomly selected reports. The sentence boundary detector achieved 99.0% precision and 98.6% recall. The overall maximal NPI precision and recall were 78.9% and 81.5% before using the UMLS Specialist Lexicon and 82.1% and 84.6% after. The overall base NPI precision and recall were 88.2% and 86.8% before using the UMLS Specialist Lexicon and 93.1% and 92.6% after, reducing false-positives by 31.1% and false-negatives by 34.3%. Conclusion: The sentence boundary detector performs excellently. After the adaptation using the UMLS Specialist Lexicon, the statistical parser's NPI performance on radiology reports increased to levels comparable to the parser's native performance in its newswire training domain and to that reported by other researchers in the general nonmedical domain. PMID:15684131

  8. Curriculum Guidelines for Predoctoral Oral Radiology.

    ERIC Educational Resources Information Center

    Journal of Dental Education, 1987

    1987-01-01

    The American Association of Dental Schools' guidelines for oral radiology curricula give an overview of the field and its interrelationships with other fields and outline the primary educational objectives, prerequisites, core content, specific behavioral objectives, sequencing, faculty, facilities, and occupational hazards to be considered in…

  9. Quality measures and pediatric radiology: suggestions for the transition to value-based payment.

    PubMed

    Heller, Richard E; Coley, Brian D; Simoneaux, Stephen F; Podberesky, Daniel J; Hernanz-Schulman, Marta; Robertson, Richard L; Donnelly, Lane F

    2017-06-01

    Recent political and economic factors have contributed to a meaningful change in the way that quality in health care, and by extension value, are viewed. While quality is often evaluated on the basis of subjective criteria, pay-for-performance programs that link reimbursement to various measures of quality require use of objective and quantifiable measures. This evolution to value-based payment was accelerated by the 2015 passage of the Medicare Access and CHIP (Children's Health Insurance Program) Reauthorization Act (MACRA). While many of the drivers of these changes are rooted in federal policy and programs such as Medicare and aimed at adult patients, the practice of pediatrics and pediatric radiology will be increasingly impacted. This article addresses issues related to the use of quantitative measures to evaluate the quality of services provided by the pediatric radiology department or sub-specialty section, particularly as seen from the viewpoint of a payer that may be considering ways to link payment to performance. The paper concludes by suggesting a metric categorization strategy to frame future work on the subject.

  10. (Lack of) Measurable Clinical or Knowledge Gains From Resident Participation in Noon Conference.

    PubMed

    Meyer, Nathaniel B; Gaetke-Udager, Kara; Shampain, Kimberly L; Spencer, Amy; Cohan, Richard H; Davenport, Matthew S

    2018-06-01

    The objective of this study was to determine whether noon conference attendance by diagnostic radiology residents is predictive of measurable performance. This single-center retrospective Health Insurance and Portability and Accountability Act (HIPAA)-compliant cross-sectional study was considered "not regulated" by the institutional review board. All diagnostic radiology residents who began residency training from 2008 to 2012 were included (N = 54). Metrics of clinical performance and knowledge were collected, including junior and senior precall test results, American Board of Radiology scores (z-score transformed), American College of Radiology in-training scores (years 1-3), on-call "great call" and minor and major discrepancy rates, on-call and daytime case volumes, and training rotation scores. Multivariate regression models were constructed to determine if conference attendance, match rank order, or starting year could predict these outcomes. Pearson bivariate correlations were calculated. Senior precall test results were moderately correlated with American Board of Radiology (r = 0.41) and American College of Radiology (r = 0.38-0.48) test results and mean rotation scores (r = 0.41), indicating moderate internal validity. However, conference attendance, match rank order, and year of training did not correlate with (r = -0.16-0.16) or predict (P > .05) measurable resident knowledge. On multivariate analysis, neither match rank order (P = .14-.96) nor conference attendance (P = .10-.88) predicted measurable clinical efficiency or accuracy. Year started training predicted greater cross-sectional case volume (P < .0001, β = 0.361-0.516) and less faculty-to-resident feedback (P < 0.0001, β = [-0.628]-[-0.733]). Residents with lower conference attendance are indistinguishable from those who attend more frequently in a wide range of clinical and knowledge-based performance assessments, suggesting that required attendance may not be necessary to gain certain measurable core competencies. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  11. Identification of Long Bone Fractures in Radiology Reports Using Natural Language Processing to Support Healthcare Quality Improvement

    PubMed Central

    Masino, Aaron J.; Casper, T. Charles; Dean, Jonathan M.; Bell, Jamie; Enriquez, Rene; Deakyne, Sara; Chamberlain, James M.; Alpern, Elizabeth R.

    2016-01-01

    Summary Background Important information to support healthcare quality improvement is often recorded in free text documents such as radiology reports. Natural language processing (NLP) methods may help extract this information, but these methods have rarely been applied outside the research laboratories where they were developed. Objective To implement and validate NLP tools to identify long bone fractures for pediatric emergency medicine quality improvement. Methods Using freely available statistical software packages, we implemented NLP methods to identify long bone fractures from radiology reports. A sample of 1,000 radiology reports was used to construct three candidate classification models. A test set of 500 reports was used to validate the model performance. Blinded manual review of radiology reports by two independent physicians provided the reference standard. Each radiology report was segmented and word stem and bigram features were constructed. Common English “stop words” and rare features were excluded. We used 10-fold cross-validation to select optimal configuration parameters for each model. Accuracy, recall, precision and the F1 score were calculated. The final model was compared to the use of diagnosis codes for the identification of patients with long bone fractures. Results There were 329 unique word stems and 344 bigrams in the training documents. A support vector machine classifier with Gaussian kernel performed best on the test set with accuracy=0.958, recall=0.969, precision=0.940, and F1 score=0.954. Optimal parameters for this model were cost=4 and gamma=0.005. The three classification models that we tested all performed better than diagnosis codes in terms of accuracy, precision, and F1 score (diagnosis code accuracy=0.932, recall=0.960, precision=0.896, and F1 score=0.927). Conclusions NLP methods using a corpus of 1,000 training documents accurately identified acute long bone fractures from radiology reports. Strategic use of straightforward NLP methods, implemented with freely available software, offers quality improvement teams new opportunities to extract information from narrative documents. PMID:27826610

  12. Curricular Guidelines for Dental Auxiliary Radiology.

    ERIC Educational Resources Information Center

    Journal of Dental Education, 1981

    1981-01-01

    AADS curricular guidelines suggest objectives for these areas of dental auxiliary radiology: physical principles of X-radiation in dentistry, related radiobiological concepts, principles of radiologic health, radiographic technique, x-ray films and intensifying screens, factors contributing to film quality, darkroom, and normal variations in…

  13. Single-centre experience of radiation exposure in acute surgical patients: assessment of therapeutic impact and future recommendations.

    PubMed

    Fitzmaurice, Gerard J; Brown, Robin; Cranley, Brian; Conlon, Enda F; Todd, R Alan J; O'Donnell, Mark E

    2010-09-01

    Radiological investigations have become a key adjunct in patient management and consequently radiation exposure to patients is increasing. The study objectives were to examine the use of radiological investigations in the management of acute surgical patients and to assess whether a guideline-based radiation exposure risk/benefit analysis can aid in the choice of radiological investigation used. A prospective observational study was completed over a 12-week period from April to July 2008 for all acute surgical admissions. Data recorded included demographics, clinical presentation, differential diagnosis, investigations, surgical interventions, and final clinical outcome. The use of radiological investigative modalities as an adjunct to clinical assessment was then evaluated against The Royal College of Radiologists (RCR) guidelines. A total of 380 acute surgical admissions (M = 174, F = 185, children = 21) were assessed during the study period. Seven hundred thirty-four radiological investigations were performed with a mean of 1.93 investigations per patient. Based on the RCR guidelines, 680 (92.6%) radiological investigations were warranted and included 142 CT scans (19.3%), 129 chest X-rays (17.6%), and 85 abdominal X-rays (11.6%). Clinically, radiological imaging complemented surgical management in 326 patients (85.8%) and the management plan remained unchanged for the remaining 54 patients (14.2%). This accounted for an average radiation dose of 4.18 millisievert (mSv) per patient or 626 days of background radiation exposure. CT imaging was responsible for the majority of the radiation exposure, with a total of 1310 mSv (82.6%) of the total radiation exposure being attributed to CT imaging in 20.8% of acute admissions. Subgroup analysis demonstrated that 92.8% of the CT scans performed were appropriate. Radiation exposure was generally low for the majority of acute surgical admissions. However, it is recommended that CT imaging requests be evaluated carefully, particularly for patients with clinically confirmed pathologies and in younger women.

  14. How Useful Are Skeletal Surveys in the Second Year of Life?

    ERIC Educational Resources Information Center

    Hansen, Karen Kirhofer; Campbell, Kristine A.

    2009-01-01

    Objective: To evaluate the utility of skeletal surveys in cases of possible physical abuse in the second year of life. Methods: Radiology records for all children under 24 months of age referred to our child protection team from January 2002 through November 2006, who had a skeletal survey performed and/or interpreted by the pediatric radiologists…

  15. Determining procedures for simulation-based training in radiology: a nationwide needs assessment.

    PubMed

    Nayahangan, Leizl Joy; Nielsen, Kristina Rue; Albrecht-Beste, Elisabeth; Bachmann Nielsen, Michael; Paltved, Charlotte; Lindorff-Larsen, Karen Gilboe; Nielsen, Bjørn Ulrik; Konge, Lars

    2018-06-01

    New training modalities such as simulation are widely accepted in radiology; however, development of effective simulation-based training programs is challenging. They are often unstructured and based on convenience or coincidence. The study objective was to perform a nationwide needs assessment to identify and prioritize technical procedures that should be included in a simulation-based curriculum. A needs assessment using the Delphi method was completed among 91 key leaders in radiology. Round 1 identified technical procedures that radiologists should learn. Round 2 explored frequency of procedure, number of radiologists performing the procedure, risk and/or discomfort for patients, and feasibility for simulation. Round 3 was elimination and prioritization of procedures. Response rates were 67 %, 70 % and 66 %, respectively. In Round 1, 22 technical procedures were included. Round 2 resulted in pre-prioritization of procedures. In round 3, 13 procedures were included in the final prioritized list. The three highly prioritized procedures were ultrasound-guided (US) histological biopsy and fine-needle aspiration, US-guided needle puncture and catheter drainage, and basic abdominal ultrasound. A needs assessment identified and prioritized 13 technical procedures to include in a simulation-based curriculum. The list may be used as guide for development of training programs. • Simulation-based training can supplement training on patients in radiology. • Development of simulation-based training should follow a structured approach. • The CAMES Needs Assessment Formula explores needs for simulation training. • A national Delphi study identified and prioritized procedures suitable for simulation training. • The prioritized list serves as guide for development of courses in radiology.

  16. Quantitative computed tomography (QCT) as a radiology reporting tool by using optical character recognition (OCR) and macro program.

    PubMed

    Lee, Young Han; Song, Ho-Taek; Suh, Jin-Suck

    2012-12-01

    The objectives are (1) to introduce a new concept of making a quantitative computed tomography (QCT) reporting system by using optical character recognition (OCR) and macro program and (2) to illustrate the practical usages of the QCT reporting system in radiology reading environment. This reporting system was created as a development tool by using an open-source OCR software and an open-source macro program. The main module was designed for OCR to report QCT images in radiology reading process. The principal processes are as follows: (1) to save a QCT report as a graphic file, (2) to recognize the characters from an image as a text, (3) to extract the T scores from the text, (4) to perform error correction, (5) to reformat the values into QCT radiology reporting template, and (6) to paste the reports into the electronic medical record (EMR) or picture archiving and communicating system (PACS). The accuracy test of OCR was performed on randomly selected QCTs. QCT as a radiology reporting tool successfully acted as OCR of QCT. The diagnosis of normal, osteopenia, or osteoporosis is also determined. Error correction of OCR is done with AutoHotkey-coded module. The results of T scores of femoral neck and lumbar vertebrae had an accuracy of 100 and 95.4 %, respectively. A convenient QCT reporting system could be established by utilizing open-source OCR software and open-source macro program. This method can be easily adapted for other QCT applications and PACS/EMR.

  17. [Marketing mix in a radiology department: challenges for future radiologists in management].

    PubMed

    Claikens, B

    1998-08-01

    Radiology has gained an enviable position among medial specialities. Developments in new technology expand its horizons and the volume of radiologic imaging techniques and procedures increase far more than the overall growth in health care services. In this position radiology has become a prime target for restrictions, cutbacks, controlled financing in an area of managed care and new national health care policy based on partially fixed budgets. Future health care takers have to choose the best available diagnostic and therapeutic techniques. Evidence based medicine, cost-utility analysis, diagnostic performance analysis, patient outcome analysis, technology assessment and guidelines for practice are means to guide us through our obligatory choice. Our major objective is to use the most performant available imaging technique or intervention to achieve the best possible outcome for our patient at lower possible costs. A strategic response from radiologists is required to meet the imperatives of this new management situation. They must do far more than interpret imaging procedures. They must work as efficient managers of imaging resources, organise their practices and define their marketing-strategies using the different, so-called, marketing-mix elements. The challenges will be great but the rewards are worth our best efforts. In this article we highlight the marketing responsibilities of future radiologists and their clinical practice in this new socio-economic environment and we present different useful marketing tools.

  18. An Integrated Interactive-Spaced Education Radiology Curriculum for Preclinical Students.

    PubMed

    Tshibwabwa, Eli; Mallin, Robert; Fraser, Madeleine; Tshibwabwa, Martin; Sanii, Reza; Rice, James; Cannon, Jenifer

    2017-01-01

    The objective of this study is to determine whether a radiology module, together with online spaced education, helps students of an integrated problem-based learning (PBL) curriculum increase their radiology knowledge and long-term retention. Second-year students at the American University of Antigua College of Medicine participated in small groups of ten students each into two 2 h of radiology laboratories. The study comprised two cohorts: winter and fall 2013 students (control group) and 2014 students (experimental group). Both groups used face-to-face PBL. The students of the experimental group received additional online-spaced education. The skills were assessed for both groups before the beginning of laboratories and 4 weeks and 7 months after laboratories. There was no significant difference on pretest between the control and experimental groups. On completion of the radiology laboratories, comparison of test results before and after training showed net improvement for both groups. The corresponding difference for the experimental group was higher compared to the one for the control group (7.83 vs. 6.21, P < 0.001). The difference between the scores on delayed test and pretest showed that the students of both groups demonstrated average knowledge improvement even though their level of performance was slightly below the posttest. The corresponding difference for the experimental group did not differ much from the posttest ( P > 0.05), and no significant difference of scores was observed 7 months later for either group. Further, a higher percentage of the students in the experimental group strongly agreed that their learning objectives were met (92% vs. 71%, P > 0.001), and this trend persisted throughout the study. Online spaced education combined to a face-to-face PBL enhances not only the student's knowledge of basic radiology along with his/her self-assessment skills but also the long-term retention of radiology material and satisfaction with the integrated interactive system-based module. Future research is needed to see if medical students in need of additional education support may benefit from spaced education in the field of remediation.

  19. Job Aids for Using Preventive Radiological/Nuclear Detection Equipment for Consequence Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buddemeier, Brooke R.; Haynes, Daniel; Wood-Zika, Annmarie R.

    The overall objective of this project is to research, evaluate, and test first responder preventive radiological/nuclear detection equipment (PRND) to provide state and local agencies with guidance on how to best use this equipment for response after a radiological/nuclear release or detonation.

  20. X-ray system simulation software tools for radiology and radiography education.

    PubMed

    Kengyelics, Stephen M; Treadgold, Laura A; Davies, Andrew G

    2018-02-01

    To develop x-ray simulation software tools to support delivery of radiological science education for a range of learning environments and audiences including individual study, lectures, and tutorials. Two software tools were developed; one simulated x-ray production for a simple two dimensional radiographic system geometry comprising an x-ray source, beam filter, test object and detector. The other simulated the acquisition and display of two dimensional radiographic images of complex three dimensional objects using a ray casting algorithm through three dimensional mesh objects. Both tools were intended to be simple to use, produce results accurate enough to be useful for educational purposes, and have an acceptable simulation time on modest computer hardware. The radiographic factors and acquisition geometry could be altered in both tools via their graphical user interfaces. A comparison of radiographic contrast measurements of the simulators to a real system was performed. The contrast output of the simulators had excellent agreement with measured results. The software simulators were deployed to 120 computers on campus. The software tools developed are easy-to-use, clearly demonstrate important x-ray physics and imaging principles, are accessible within a standard University setting and could be used to enhance the teaching of x-ray physics to undergraduate students. Current approaches to teaching x-ray physics in radiological science lack immediacy when linking theory with practice. This method of delivery allows students to engage with the subject in an experiential learning environment. Copyright © 2017. Published by Elsevier Ltd.

  1. Mission Analysis for Using Preventive Radiological/Nuclear Detection Equipment for Consequence Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buddemeier, Brooke R.; Wood-Zika, Annmarie R.; Haynes, Daniel

    The overall objective of this project is to research, evaluate, and test first responder preventive radiological/nuclear detection (PRND) equipment to provide state and local agencies with scientific guidance on how to effectively use this equipment for response after a radiological/nuclear release or detonation. While the equipment being tested in this effort has been specifically designed by technology manufacturers and purchased by responders for preventive detection and source interdiction operations, the fleet of PRND equipment can help fill critical needs for radiological instrumentation should a consequence management (CM) response take place, as it is currently the most widely available and fieldedmore » radiological instrumentation by state and local agencies. This effort will provide scientific guidance on the most effective way to utilize this class of equipment for consequence management missions. Gaining a better understanding of how PRND equipment can operate and perform for these missions will allow for recommendations on the tactical approach responders can use for consequence management operations. PRND equipment has been placed into service by federal, state, and local agencies throughout the nation. If the equipment capability and limitations are taken into account, this large inventory can be leveraged to support the emergency response in the aftermath of a radiological or nuclear event. With several hundred makes and models of PRND equipment, often with significantly different detection capabilities that do not align with their nominal PRND equipment type, development of a streamlined categorization scheme with respect to consequence management missions was the first step to identifying safe and effective uses of PRND equipment for radiological/nuclear incident response.« less

  2. Independent Verification Final Summary Report for the David Witherspoon, Inc. 1630 Site Knoxville, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    P.C. Weaver

    2009-04-29

    The primary objective of the independent verification was to determine if BJC performed the appropriate actions to meet the specified “hot spot” cleanup criteria of 500 picocuries per gram (pCi/g) uranium-238 (U-238) in surface soil. Specific tasks performed by the independent verification team (IVT) to satisfy this objective included: 1) performing radiological walkover surveys, and 2) collecting soil samples for independent analyses. The independent verification (IV) efforts were designed to evaluate radioactive contaminants (specifically U-238) in the exposed surfaces below one foot of the original site grade, given that the top one foot layer of soil on the site wasmore » removed in its entirety.« less

  3. Integrating DICOM structure reporting (SR) into the medical imaging informatics data grid

    NASA Astrophysics Data System (ADS)

    Lee, Jasper; Le, Anh; Liu, Brent

    2008-03-01

    The Medical Imaging Informatics (MI2) Data Grid developed at the USC Image Processing and Informatics Laboratory enables medical images to be shared securely between multiple imaging centers. Current applications include an imaging-based clinical trial setting where multiple field sites perform image acquisition and a centralized radiology core performs image analysis, often using computer-aided diagnosis tools (CAD) that generate a DICOM-SR to report their findings and measurements. As more and more CAD tools are being developed in the radiology field, the generated DICOM Structure Reports (SR) holding key radiological findings and measurements that are not part of the DICOM image need to be integrated into the existing Medical Imaging Informatics Data Grid with the corresponding imaging studies. We will discuss the significance and method involved in adapting DICOM-SR into the Medical Imaging Informatics Data Grid. The result is a MI2 Data Grid repository from which users can send and receive DICOM-SR objects based on the imaging-based clinical trial application. The services required to extract and categorize information from the structured reports will be discussed, and the workflow to store and retrieve a DICOM-SR file into the existing MI2 Data Grid will be shown.

  4. Radiological Defense. Planning and Operations Guide. Revised.

    ERIC Educational Resources Information Center

    Office of Civil Defense (DOD), Washington, DC.

    This guide is a reprint of published and draft materials from the Federal Civil Defense Guide. This guide is intended to assist the student in planning, developing, implementing and operating a local, county, or state radiological defense (RADEF) system. The state and local radiological defense program objectives are to create an effective and…

  5. Compression ultrasonography of the lower extremity with portable vascular ultrasonography can accurately detect deep venous thrombosis in the emergency department.

    PubMed

    Crisp, Jonathan G; Lovato, Luis M; Jang, Timothy B

    2010-12-01

    Compression ultrasonography of the lower extremity is an established method of detecting proximal lower extremity deep venous thrombosis when performed by a certified operator in a vascular laboratory. Our objective is to determine the sensitivity and specificity of bedside 2-point compression ultrasonography performed in the emergency department (ED) with portable vascular ultrasonography for the detection of proximal lower extremity deep venous thrombosis. We did this by directly comparing emergency physician-performed ultrasonography to lower extremity duplex ultrasonography performed by the Department of Radiology. This was a prospective, cross-sectional study and diagnostic test assessment of a convenience sample of ED patients with a suspected lower extremity deep venous thrombosis, conducted at a single-center, urban, academic ED. All physicians had a 10-minute training session before enrolling patients. ED compression ultrasonography occurred before Department of Radiology ultrasonography and involved identification of 2 specific points: the common femoral and popliteal vessels, with subsequent compression of the common femoral and popliteal veins. The study result was considered positive for proximal lower extremity deep venous thrombosis if either vein was incompressible or a thrombus was visualized. Sensitivity and specificity were calculated with the final radiologist interpretation of the Department of Radiology ultrasonography as the criterion standard. A total of 47 physicians performed 199 2-point compression ultrasonographic examinations in the ED. Median number of examinations per physician was 2 (range 1 to 29 examinations; interquartile range 1 to 5 examinations). There were 45 proximal lower extremity deep venous thromboses observed on Department of Radiology evaluation, all correctly identified by ED 2-point compression ultrasonography. The 153 patients without proximal lower extremity deep venous thrombosis all had a negative ED compression ultrasonographic result. One patient with a negative Department of Radiology ultrasonographic result was found to have decreased compression of the popliteal vein on ED compression ultrasonography, giving a single false-positive result, yet repeated ultrasonography by the Department of Radiology 1 week later showed a popliteal deep venous thrombosis. The sensitivity and specificity of ED 2-point compression ultrasonography for deep venous thrombosis were 100% (95% confidence interval 92% to 100%) and 99% (95% confidence interval 96% to 100%), respectively. Emergency physician-performed 2-point compression ultrasonography of the lower extremity with a portable vascular ultrasonographic machine, conducted in the ED by this physician group and in this patient sample, accurately identified the presence and absence of proximal lower extremity deep venous thrombosis. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  6. Context matters: the structure of task goals affects accuracy in multiple-target visual search.

    PubMed

    Clark, Kait; Cain, Matthew S; Adcock, R Alison; Mitroff, Stephen R

    2014-05-01

    Career visual searchers such as radiologists and airport security screeners strive to conduct accurate visual searches, but despite extensive training, errors still occur. A key difference between searches in radiology and airport security is the structure of the search task: Radiologists typically scan a certain number of medical images (fixed objective), and airport security screeners typically search X-rays for a specified time period (fixed duration). Might these structural differences affect accuracy? We compared performance on a search task administered either under constraints that approximated radiology or airport security. Some displays contained more than one target because the presence of multiple targets is an established source of errors for career searchers, and accuracy for additional targets tends to be especially sensitive to contextual conditions. Results indicate that participants searching within the fixed objective framework produced more multiple-target search errors; thus, adopting a fixed duration framework could improve accuracy for career searchers. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  7. An Evidence-Based Approach to the Management of Children with Morquio A Syndrome Presenting with Craniocervical Pathology.

    PubMed

    Williams, Nicole; Narducci, Alessandro; Eastwood, Deborah M; Cleary, Maureen; Thompson, Dominic

    2018-06-12

    Retrospective case series OBJECTIVE.: To review clinical and radiological outcomes of craniovertebral surgery in children with Morquio A syndrome (Mucopolysaccharidosis type IVA) and develop an evidence-based management algorithm. Myelopathy secondary to craniovertebral pathology is a common cause of neurological disability in Morquio A syndrome. Previously unresolved surgical controversies include the value of surveillance, surgical indications and operative technique. A retrospective case-based review of children with Morquio A syndrome and craniovertebral pathology seen in a tertiary referral paediatric centre from 1992-2016 was performed. Patients treated non-operatively and operatively were included. Medical records and imaging were reviewed to determine clinical and radiological findings at initial assessment, prior to cervical spine surgery, early post-operative period and final follow-up. The clinical outcomes of interest were neurological status and mobility at follow-up, complications and need for further surgery. Twenty-seven patients were included. Surgical indications were radiological evidence of cervicomedullary compression alone (6 cases) or with clinical evidence of myelopathy (12 cases). Eighteen patients (median age 6.2 years, range 3.5 - 15.9 years) underwent surgery, with median follow-up of 8.5years. Occiput to upper cervical spine fusion with C1 decompression was performed in all cases with the addition of autologous calvarial graft in young patients (12 cases) and occipital-cervical plate fixation in older children (6 cases). Neurological improvement occurred in 38% of cases but by one functional level only. Six of 9 conservatively treated patients remained independent walkers. Surgery for craniovertebral pathology is required in the majority of children with Morquio A syndrome. Close clinical and radiological surveillance is essential for timely intervention. Occiput to cervical fusion is safe and feasible even in young patients and improves clinical and radiological parameters. 4.

  8. 324 Building Baseline Radiological Characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R.J. Reeder, J.C. Cooper

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building.

  9. Application of Analytical Hierarchy Process Approach for Service Quality Evaluation in Radiology Departments: A Cross-Sectional Study

    PubMed Central

    Alimohammadzadeh, Khalil; Bahadori, Mohammadkarim; Hassani, Fariba

    2016-01-01

    Background: Radiology department as a service provider organization requires realization of quality concept concerning service provisioning knowledge, satisfaction and all issues relating to the customer as well as quality assurance and improvement issues. At present, radiology departments in hospitals are regarded as income generating units and they should continuously seek performance improvement so that they can survive in the changing and competitive environment of the health care sector. Objectives: The aim of this study was to propose a method for ranking of radiology departments in selected hospitals of Tehran city using analytical hierarchical process (AHP) and quality evaluation of their service in 2015. Materials and Methods: This study was an applied and cross-sectional study, carried out in radiology departments of 6 Tehran educational hospitals in 2015. The hospitals were selected using non-probability and purposeful method. Data gathering was performed using customized joint commission international (JCI) standards. Expert Choice 10.0 software was used for data analysis. AHP method was used for prioritization. Results: “Management and empowerment of human resources’’ (weight = 0.465) and “requirements and facilities” (weight = 0.139) were of highest and lowest significance respectively in the overall ranking of the hospitals. MS (weight = 0.316), MD (weight = 0.259), AT (weight = 0.14), TS (weight = 0.108), MO (weight = 0.095), and LH (0.082) achieved the first to sixth rankings respectively. Conclusion: The use of AHP method can be promising for fostering the evaluation method and subsequently promotion of the efficiency and effectiveness of the radiology departments. The present model can fill in the gap in the accreditation system of the country’s hospitals in respect with ranking and comparing them considering the significance and value of each individual criteria and standard. Accordingly, it can predict an integration of qualitative and quantitative criteria involved and thereby take a decisive step towards further efficiency and effectiveness of the health care evaluation systems. PMID:27127577

  10. Terminology and Reporting Criteria for Radiofrequency Ablation of Tumors in the Scientific Literature: Systematic Review of Compliance with Reporting Standards

    PubMed Central

    Kang, Tae Wook; Lee, Min Woo; Kim, Young-sun; Choi, Dongil; Lim, Hyo Keun

    2014-01-01

    Objective To perform a systematic review of compliance with standardized terminology and reporting criteria for radiofrequency (RF) tumor ablation, proposed by the International Working Group on Image-Guided Tumor Ablation in 2003, in the published reports. Materials and Methods Literature search in the PubMed database was performed using index keywords, PubMed limit system, and eligibility criteria. The entire content of each article was reviewed to assess the terminology used for procedure terms, imaging findings, therapeutic efficacy, follow-up, and complications. Accuracy of the terminology and the use of alternative terms instead of standard terminology were analyzed. In addition, disparities in accuracy of terminology in articles according to the medical specialty and the type of radiology journal were evaluated. Results Among the articles (n = 308) included in this study, the accuracy of the terms 'procedure or session', 'treatment', 'index tumor', 'ablation zone', 'technical success', 'primary technique effectiveness rate', 'secondary technique effectiveness rate', 'local tumor progression', 'major complication', and 'minor complication' was 97% (298/307), 97% (291/300), 8% (25/307), 65% (103/159), 55% (52/94), 33% (42/129), 94% (17/18), 45% (88/195), 99% (79/80), and 100% (77/77), respectively. The overall accuracy of each term showed a tendency to improve over the years. The most commonly used alternative terms for 'technical success' and 'local tumor progression' were 'complete ablation' and 'local (tumor) recurrence', respectively. The accuracy of terminology in articles published in radiology journals was significantly greater than that of terminology in articles published in non-radiology journals, especially in Radiology and The Journal of Vascular and Interventional Radiology. Conclusion The proposal for standardization of terminology and reporting criteria for RF tumor ablation has been gaining support according to the recently published scientific reports, especially in the field of radiology. However, more work is still needed for the complete standardization of terminology. PMID:24497798

  11. Telemedicine-based system for quality management and peer review in radiology.

    PubMed

    Morozov, Sergey; Guseva, Ekaterina; Ledikhova, Natalya; Vladzymyrskyy, Anton; Safronov, Dmitry

    2018-06-01

    Quality assurance is the key component of modern radiology. A telemedicine-based quality assurance system helps to overcome the "scoring" approach and makes the quality control more accessible and objective. A concept for quality assurance in radiology is developed. Its realization is a set of strategies, actions, and tools. The latter is based on telemedicine-based peer review of 23,199 computed tomography (CT) and magnetic resonance imaging (MRI) images. The conception of the system for quality management in radiology represents a chain of actions: "discrepancies evaluation - routine support - quality improvement activity - discrepancies evaluation". It is realized by an audit methodology, telemedicine, elearning, and other technologies. After a year of systemic telemedicine-based peer reviews, the authors have estimated that clinically significant discrepancies were detected in 6% of all cases, while clinically insignificant ones were found in 19% of cases. Most often, problems appear in musculoskeletal records; 80% of the examinations have diagnostic or technical imperfections. The presence of routine telemedicine support and personalized elearning allowed improving the diagnostics quality. The level of discrepancies has decreased significantly (p < 0.05). The telemedicine-based peer review system allows improving radiology departments' network effectiveness. • "Scoring" approach to radiologists' performance assessment must be changed. • Telemedicine peer review and personalized elearning significantly decrease the number of discrepancies. • Teleradiology allows linking all primary-level hospitals to a common peer review network.

  12. Use of personal digital assistants in diagnostic radiology resident education.

    PubMed

    Nishino, Mizuki; Busch, James M; Wei, Jesse; Barbaras, Larry; Yam, Chun-Shan; Hatabu, Hiroto

    2004-10-01

    Personal digital assistants (PDAs) are gaining widespread use in the medical community. We introduced a PDA-based mobile system that provides departmental and educational information with a seamless connection to the intranet. The objective of this study is to determine the impact a PDA has on educational resources (learning or data reference) brought to work and used at home by a radiology resident based on user surveys. Survey was performed on 32 radiology residents in our department before and 6 months after the release of the PDA-based system. We assessed the changes in (1) sources of learning at home and at work, and in (2) data reference. The second survey also evaluated the usefulness of each component of the system. After the release of the PDA-based mobile system, the use of "digital books and references" as data references and educational resources that were brought to work every day significantly increased (P = .016, P < .0001, respectively). "Traditional books and references" remained the "most useful source in learning radiology"; however, "digital books and references" increased as the residents' first choice from 0% to 16% within 6 months of introducing the package (P = .125). The introduction of a PDA-based system consisting of educational and departmental information had a statistically significant impact in increasing the use of digitized information in radiology resident education.

  13. What makes a great radiology review course lecture: the Ottawa radiology resident review course experience.

    PubMed

    Cao, Lilly; McInnes, Matthew D F; Ryan, John O

    2014-02-01

    Little objective evidence exists regarding what makes a good lecture. Our purpose was to determine qualities of radiology review course lectures that are associated with positive audience evaluation. 57 presentations from the Ottawa Resident Review Course (2012) were analyzed by a PGY4 radiology resident blinded to the result of audience evaluation. Objective data extracted were: slides per minute, lines of text per text slide, words per text slide, cases per minute, images per minute, images per case, number of audience laughs, number of questions posed to the audience, number of summaries, inclusion of learning objectives, ending on time, use of pre/post-test and use of special effects. Mean audience evaluation scores for each talk from daily audience evaluations (up to 60 per talk) were standardized out of 100. Correlation coefficient was calculated between continuous variables and audience evaluation scores. Student T test was performed on categorical variables and audience evaluation scores. Strongest positive association with audience evaluation scores was for image quality (r = 0.57) and number of times the audience laughed (r = 0.3). Strongest negative association was between images per case and audience scores (r = -0.25). Talks with special effects were rated better (mean score 94.3 vs. 87.1, p < 0.001). Talks with the highest image quality were rated better (mean score 94.1 vs. 87.5, p < 0.001). Talks which contained a pre/post-test were rated better (mean score 92 vs. 87.8, p = 0.004). Many factors go into making a great review course lecture. At the University of Ottawa Resident Review Course, high quality images, use of special effects, use of pre/post-test and humor were most strongly associated with high audience evaluation scores. High image volume per case may be negatively associated with audience evaluation scores.

  14. Accuracy of vertical height measurements on direct digital panoramic radiographs using posterior mandibular implants and metal balls as reference objects.

    PubMed

    Vazquez, L; Nizamaldin, Y; Combescure, C; Nedir, R; Bischof, M; Dohan Ehrenfest, D M; Carrel, J-P; Belser, U C

    2013-01-01

    Conventional panoramic radiography, a widely used radiographic examination tool in implant treatment planning, allows evaluation of the available bone height before inserting posterior mandibular implants. Image distortion and vertical magnification due to projection geometry is well described for rotational panoramic radiographs. To assess the accuracy of vertical height measurements on direct digital panoramic radiographs, implants and metal balls positioned in the posterior mandible were used as radio-opaque reference objects. The reproducibility of the measuring method was assessed by the inter- and intraobserver agreements. Direct digital panoramic radiographs, performed using a Kodak 8000C (Eastman Kodak Company, Rochester, NY), of 17 partially edentulous patients (10 females, 7 males, mean age 65 years) were selected from an X-ray database gathered during routine clinical evaluation of implant sites. Proprietary software and a mouse-driven calliper were used to measure the radiological length of 25 implants and 18 metal reference balls, positioned in mandibular posterior segments. The distortion ratio (DR) was calculated by dividing the radiological implant length by the implant's real length and the radiological ball height by the ball's real height. Mean vertical DR was 0.99 for implants and 0.97 for balls, and was unrelated to mandibular sites, side, age, gender or observer. Inter- and intraobserver agreements were acceptable for both reference objects. Vertical measurements had acceptable accuracy and reproducibility when a software-based calibrated measurement tool was used, confirming that digital panoramic radiography can be reliably utilized to determine the pre-operative implant length in premolar and molar mandibular segments.

  15. Scientific Evaluation of Nanomaterials of TiO{sub 2} and Related Derivatives in a Variety of Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spitler, Timothy M; Stewart, Matthew; Pasquier, Aurelien Du

    Altair Nanotechnolgies, Inc. (Altair) has performed and hereby reports on research and development of novel nanomaterials for applications in 1) advanced power storage devices, 2) sensors for chemical, biological and radiological agents and on an 3) investigation into mechanisms of living cell-nanoparticle interactions that will allow predictions of health and safety issues and potentially result in novel agents for remediation of chemical and biological hazards. The project was organized around four distinct objectives. Two of the objectives are focused on developments designed to dramatically improve the performance of rechargeable Li-Ion batteries. These efforts are based on extensions of Altair's proprietarymore » TiO{sub 2} nanoparticles and nanoparticle aggregates in the form of lithium titanate spinel, lithium manganates and lithium cobaltates. A third objective leverages the core Altair nanomaterials technology to develop a unique (nanosensor) platform for the error-free, "lab on a chip" detection of chemical, biological and radiological agents for hazardous materials remediation and threat detection. The innovative approach taken by the Altair/Western Michigan team develops individual nanosensor elements built upon a construct that includes a target-specific receptor molecule coupled through a signal transducing nanomolecule to a gold, TiO{sub 2} or SiO{sub 2} nanoparticle coated with a high density of strongfluorescing molecules for signal amplification The final objective focuses on interaction mechanisms between cells and nanoparticles with the goal of understanding how specific chemical and physical properties of these nanoparticles influence that interaction. The effort will examine a range of microbes that have environmental or societal importance.« less

  16. Radiologic Technology Program Standards.

    ERIC Educational Resources Information Center

    Georgia Univ., Athens. Dept. of Vocational Education.

    This publication contains statewide standards for the radiologic technology program in Georgia. The standards are divided into 12 categories; Foundations (philosophy, purpose, goals, program objectives, availability, evaluation); Admissions (admission requirements, provisional admission requirements, recruitment, evaluation and planning); Program…

  17. Radiology system evolution in the new millennium.

    PubMed

    Nauert, R C

    2001-01-01

    For many decades the practice of radiology grew slowly in America and was largely a secondary function under the control of hospitals. In more recent times it has vastly expanded its array of diagnostic, interventional, and therapeutic abilities. There is increasing consumer logic for direct access. Motivations have grown to create large independent entities with broadly diverse capabilities in order to succeed in the new millennium. Most regional markets are evolving rapidly in terms of managed care penetration, health system formation, physician practice consolidation and aggressive purchaser behavior by employers and consumers. To understand the enormity of healthcare evolution, it is useful to look at the industry's paradigm shifts in recent decades. Virtually every aspect of organizational infrastructure, delivery approaches, and the business environment has evolved markedly during the past fifty years. These changes will accelerate. To succeed financially, radiology groups must strengthen their market positions, technical capabilities, continuums of care and geographic dominance. Equally important is the wisdom of diversifying incomes into related services and businesses that provide additional related revenues. Key factors for successful development include facility market growth, full coverage of managed care contracts, high efficiency and aggressive diversification. A fully evolved system generates significant revenues and profitability by protecting and strengthening its financial position in this environment. That is accomplished through the development of strategically located radiology groups, aggressive alliances with medical practices in allied disciplines, and managed radiology departments and facilities for partner health systems. Organizational success ultimately depends on the ability to accept capitated payments under risk-bearing arrangements. The strategic business plan should be organized with the appropriate levels of detail needed to establish executive focus and priorities. These should be woven into operational and capital budgets to reflect expectations of the revenues, expenses and investments tied to the plan. While formidable, all of these objectives are realistic and can be accomplished if the right decisions are made. Initially, the entity's principle business objective is to formulate and begin implementation of methodical yet aggressive strategies for growth that are sensitive to sustaining high levels of quality patient care. The next phase features mergers with large, independent radiology practices in key geographic areas and successful acquisition of smaller practices. The objective of the final phase is to aggressively expand into select metropolitan areas with regional coverage and full teleradiology capabilities. High levels of market strength and financial performance are necessary to succeed. Passive limitations to small geographic areas and narrow practices will undermine their market position and dissolve financial strength with no hope of recovery. Only the dominant systems will survive and prosper.

  18. The role of interventional radiology in the management of surgical complications after pancreatoduodenectomy

    PubMed Central

    Sanjay, Pandanaboyana; Kellner, Maximiliane; Tait, Iain Stephen

    2012-01-01

    Objectives This study evaluates the role of interventional radiology (IR) in the management of postoperative complications after pancreatoduodenectomy (PD). Methods A total of 120 consecutive patients were reviewed to identify IR procedures performed for early complications after PD. Results Findings showed that 24 patients (20.0%) required urgent radiological or surgical re-intervention for early complications, including 11 instances of post-pancreatectomy haemorrhage (PPH), six intra-abdominal abscesses, two bile leaks, one pancreatic fistula and one bowel ischaemia. Three of 24 complications were managed by surgery and 21 were managed by IR. Two of 11 PPHs involved intraluminal haemorrhage (ILH) and nine involved intra-abdominal haemorrhage (IAH). One ILH was managed conservatively and one required surgical intervention. In eight of nine patients with IAH, the bleeding site was identified on computed tomography angiography, and endovascular stenting or coil embolization were performed. No patient required a re-look laparotomy following IR for haemorrhage or intra-abdominal abscess. Overall, three of 120 patients required an urgent re-look laparotomy for early complications. Conclusions Rates of major morbidity after PD remain high. However, many significant complications (PPH, pancreatic fistula, intra-abdominal abscess) can be managed by IR, reducing the need for reoperation. Re-look surgery is still required in a small percentage (2.5%) of patients. PMID:23134182

  19. Implementation of the qualities of radiodiagnostic: mammography

    NASA Astrophysics Data System (ADS)

    Pacífico, L. C.; Magalhães, L. A. G.; Peixoto, J. G. P.; Fernandes, E.

    2018-03-01

    The objective of the present study was to evaluate the expanded uncertainty of the mammographic calibration process and present the result of the internal audit performed at the Laboratory of Radiological Sciences (LCR). The qualities of the mammographic beans that are references in the LCR, comprises two irradiation conditions: no-attenuated beam and attenuated beam. Both had satisfactory results, with an expanded uncertainty equals 2,1%. The internal audit was performed, and the degree of accordance with the ISO/IEC 17025 was evaluated. The result of the internal audit was satisfactory. We conclude that LCR can perform calibrations on mammography qualities for end users.

  20. A Comprehensive Analysis of Authorship in Radiology Journals

    PubMed Central

    Dang, Wilfred; McInnes, Matthew D. F.; Kielar, Ania Z.; Hong, Jiho

    2015-01-01

    Objectives The purpose of our study was to investigate authorship trends in radiology journals, and whether International Committee of Medical Journal Editors (ICMJE) recommendations have had an impact on these trends. A secondary objective was to explore other variables associated with authorship trends. Methods A retrospective, bibliometric analysis of 49 clinical radiology journals published from 1946–2013 was conducted. The following data was exported from MEDLINE (1946 to May 2014) for each article: authors’ full name, year of publication, primary author institution information, language of publication and publication type. Microsoft Excel Visual Basics for Applications scripts were programmed to categorize extracted data. Statistical analysis was performed to determine the overall mean number of authors per article over time, impact of ICMJE guidelines, authorship frequency per journal, country of origin, article type and language of publication. Results 216,271 articles from 1946–2013 were included. A univariate analysis of the mean authorship frequency per year of all articles yielded a linear relationship between time and authorship frequency. The mean number of authors per article in 1946 (1.42) was found to have increased consistently by 0.07 authors/ article per year (R² = 0.9728, P<0.001) to 5.79 authors/article in 2013. ICMJE guideline dissemination did not have an impact on this rise in authorship frequency. There was considerable variability in mean authors per article and change over time between journals, country of origin, language of publication and article type. Conclusion Overall authorship for 49 radiology journals across 68 years has increased markedly with no demonstrated impact from ICMJE guidelines. A higher number of authors per article was seen in articles from: higher impact journals, European and Asian countries, original research type, and those journals who explicitly endorse the ICMJE guidelines. PMID:26407072

  1. Detectability of radiological images: the influence of anatomical noise

    NASA Astrophysics Data System (ADS)

    Bochud, Francois O.; Verdun, Francis R.; Hessler, Christian; Valley, Jean-Francois

    1995-04-01

    Radiological image quality can be objectively quantified by the statistical decision theory. This theory is commonly applied with the noise of the imaging system alone (quantum, screen and film noises) whereas the actual noise present on the image is the 'anatomical noise' (sum of the system noise and the anatomical texture). This anatomical texture should play a role in the detection task. This paper compares these two kinds of noises by performing 2AFC experiments and computing the area under the ROC-curve. It is shown that the 'anatomical noise' cannot be considered as a noise in the sense of Wiener spectrum approach and that the detectability performance is the same as the one obtained with the system noise alone in the case of a small object to be detected. Furthermore, the statistical decision theory and the non- prewhitening observer does not match the experimental results. This is especially the case in the low contrast values for which the theory predicts an increase of the detectability as soon as the contrast is different from zero whereas the experimental result demonstrates an offset of the contrast value below which the detectability is purely random. The theory therefore needs to be improved in order to take this result into account.

  2. Student performance and course evaluations before and after use of the Classroom Performance System ™ in a third-year veterinary radiology course.

    PubMed

    Hecht, Silke; Adams, W H; Cunningham, M A; Lane, I F; Howell, N E

    2013-01-01

    Effective teaching of veterinary radiology can be challenging in a traditional classroom environment. Audience response systems, colloquially known as "clickers," provide a means of encouraging student interaction. The purpose of this study was to compare student performance and course evaluations before and after using the Classroom Performance System™ in the third-year (fifth semester) didactic radiology course at the University of Tennessee College of Veterinary Medicine. Overall student performance was assessed by comparing median numeric final course grades (%) between years without and with use of the Classroom Performance System™. Grades of students were determined for individual instructors' sections. Student evaluations of the radiology course were compared for the years available (2007-2010). Student interactions were also evaluated subjectively by instructors who used the Classroom Performance System™. There was a significant difference (p = 0.009) between the median student grade before (2005 - 2008, median 82.2%; interquartile range 77.6-85.7%; range 61.9-95.5%) and after use of the classroom performance system (2009-2010, median 83.6%; interquartile range 79.9-87.9%; range 68.2-93.2%). There was no statistically significant difference in median student grades for individual instructors over the study period. The radiology course student evaluation scores were significantly higher in years where the Classroom Performance System™ was used in comparison to previous years (P = 0.019). Subjectively, students appeared more involved when using clickers. Findings indicated that the Classroom Performance System™ may be a useful tool for enhancing veterinary radiology education. © 2012 Veterinary Radiology & Ultrasound.

  3. [Development of an attitude-measurement questionnaire using the semantic differential technique: defining the attitudes of radiological technology students toward X-ray examination].

    PubMed

    Tamura, Naomi; Terashita, Takayoshi; Ogasawara, Katsuhiko

    2014-03-01

    In general, it is difficult to objectively evaluate the results of an educational program. The semantic differential (SeD) technique, a methodology used to measure the connotative meaning of objects, words, and concepts, can, however, be applied to the evaluation of students' attitudes. In this study, we aimed to achieve an objective evaluation of the effects of radiological technology education. We therefore investigated the attitude of radiological students using the SeD technique. We focused on X-ray examinations in the field of radiological technology science. Bipolar adjective scales were used for the SeD questionnaire. To create the questionnaire, appropriate adjectives were selected from past reports of X-ray examination practice. The participants were 32 senior students at Hokkaido University at the Division of Radiological Technology at the School of Medicine's Department of Health Sciences. All the participants completed the questionnaire. The study was conducted in early June 2012. Attitudes toward X-ray examination were identified using a factor analysis of 11 adjectives. The factor analysis revealed the following three attitudes: feelings of expectation, responsibility, and resistance. Knowledge regarding the attitudes that students have toward X-ray examination will prove useful for evaluating the effects of educational intervention. In this study, a sampling bias may have occurred due to the small sample size; however, no other biases were observed.

  4. Student Evaluations, Outcomes, and National Licensure Examinations in Radiology Education: A Narrative Review of the Literature

    PubMed Central

    Linaker, Kathleen L.

    2015-01-01

    Objective The purpose of this study was to examine literature on radiological student evaluation and outcome assessments including national board examinations. Methods A review of the literature was performed using relevant key words. Articles were retrieved through December 2012 using PubMed, ScienceDirect, ERIC, Proquest, and ICL databases along with a manual review of references. Results Of the 4716 unique abstracts reviewed by the author, 54 were found to be relevant to the purpose of this study. Student grade point average correlates with board scores in the nursing, chiropractic, and medical professions. Scores on the chiropractic college admission test and undergraduate grade point average correlate with success in professional college. There is a correlation between board scores and college attended. Board preparation programs do not appear to affect board examination scores. Conclusion Although evaluations can be effective teaching tools, they are not used by many radiology programs. Some programs have inadequate evaluations and do not allow students to review their evaluations. There are no definitive links between mastery of radiology and specific evaluations, outcomes, or pre-professional/clinical grades. Studies suggest that board examination scores reflect long-term mastery of knowledge rather than short-term memorization of facts. PMID:26770174

  5. Prevalence of Paget's disease of bone in Italy.

    PubMed

    Gennari, Luigi; Di Stefano, Marco; Merlotti, Daniela; Giordano, Nicola; Martini, Giuseppe; Tamone, Cristina; Zatteri, Roberto; De Lucchi, Roberto; Baldi, Carlo; Vattimo, Angelo; Capoccia, Silvia; Burroni, Luca; Geraci, Simone; De Paola, Vincenzo; Calabrò, Anna; Avanzati, Annalisa; Isaia, Giancarlo; Nuti, Ranuccio

    2005-10-01

    We examined the prevalence of PDB in Italy from radiological, scintigraphic, and biochemical surveys in two Italian towns. Prevalence rates varied from 0.7% to 2.4%, were higher in males than in females, and slightly differed between the two towns. Unlike previous studies in populations of British descent, no secular trend for a decreasing prevalence emerged. Clinical, radiological, and necropsy data from different countries suggested pronounced geographical variations in the prevalence of Paget's disease of bone (PDB). Despite the impact of the disease on the population, there are limited data on the prevalence of PDB in Italy. The objective of this study was to estimate the prevalence of PDB in the district of Siena (Central Italy) and Turin (Northern Italy) from radiological, biochemical, and scintigraphic surveys. We examined a sample of 1778 consecutive pelvic radiographs performed between 1999 and 2000 at the Hospital Radiology Unit in Siena and 6609 pelvic radiographs performed in 1986-1987, 1992-1993, and 1999-2002 from the Radiology Department of Molinette Hospital in Turin. In Siena, 7906 consecutive (99m)TC-MDP bone scans performed over a 4-year period (January 2000 to May 2004) were also screened for the presence of PDB, and the prevalence of elevated alkaline phosphatase (ALP) levels (>300 UI/liter) was estimated from 7449 computerized medical records over a 3-year period (January 2000 to February 2003). The finding of PDB on the pelvic radiograph and bone scan was based on standardized radiological criteria. At the end of the radiological surveys, 16/1778 pelvic PDB cases (8 males and 8 females) were observed in Siena and 41/6609 (27 males and 14 females) in Turin. The crude prevalence of the disease was 0.89% in Siena and 0.62% in Turin. Given that pelvic involvement is commonly described in 60-90% of PDB patients, the estimated overall prevalence of PDB ranged from 1.0% to 1.5% in Siena and from 0.7% to 1.0% in Turin. No decrease in the prevalence of PDB was evident after comparison of prevalence rates from different periods. Biochemical analyses showed 296/7449 subjects with elevated ALP levels and normal liver enzymes, 87 of whom had confirmed diagnosis of PDB. The estimated prevalence of biochemical PDB was 1.5%. The scintigraphic survey showed a PDB prevalence of 194/7906 (2.4%), which was significantly higher than the radiological and biochemical estimates. Our surveys suggest that PDB in Italy has an estimated prevalence of at least 1%, comparable with that observed in United States and other European countries, but lower than that described in Britain and New Zealand. No secular trend for a decreasing prevalence of PDB was observed.

  6. Relationship Between Dental Hygiene Students' Performance in an Oral Radiology Course and the National Board Dental Hygiene Examination: A Retrospective Study.

    PubMed

    Liang, Hui; DeWald, Janice P; Solomon, Eric S

    2018-02-01

    Dental hygiene students' performance in oral radiology courses may give an early indication of their readiness prior to taking the National Board Dental Hygiene Examination (NBDHE). The aim of this study was to determine the relationship between dental hygiene students' performance in an oral radiology lecture course and their performance on the NBDHE. Data were collected for all 117 dental hygiene students at Texas A&M University College of Dentistry from 2006 to 2009 who took the NBDHE during their second year of the program. Their final grades and scores on three written section examinations in an oral radiology course taken in their first year were compared with their overall NBDHE scores and raw scores on the oral radiology and case study sections. Moderate correlations (0.3

  7. Use of a simulation laboratory to train radiology residents in the management of acute radiologic emergencies.

    PubMed

    Sarwani, Nabeel; Tappouni, Rafel; Flemming, Donald

    2012-08-01

    Simulation laboratories use realistic clinical scenarios to train physicians in a controlled environment, especially in potentially life-threatening complications that require prompt management. The objective of our study was to develop a comprehensive program using the simulation laboratory to train radiology residents in the management of acute radiologic emergencies. All radiology residents attended a dedicated simulation laboratory course lasting 3 hours, divided over two sessions. Training included basic patient management skills, management of a tension pneumothorax, massive hemorrhage, and contrast agent reactions. Participants were presented with 20 multiple-choice questions before and after the course. Pre- and posttest results were analyzed, and the McNemar test was used to compare correct responses by individual question. Twenty-six radiology residents attended the class. The average pre- and posttest scores and the average difference between the scores for all residents were 13.8, 17.1, and 3.3, respectively (p < 0.0001). Incorrect answers on the pretest examination that were subsequently answered correctly concerned administration of epinephrine for severe reactions, management of a tension pneumothorax, oxygen therapy, ECG placement, cardiopulmonary resuscitation technique, and where to stand during a code situation. Persistent incorrect answers concerned vasovagal reactions and emergency telephone numbers at an off-site imaging center. Simulation laboratories can be used to teach crisis management and crisis resource management for radiology residents and should be part of the education toolbox. Defined objectives lead to a comprehensive course dealing with the management of acute radiologic emergencies. Such programs can improve the role of radiologists as members of the health care team.

  8. Development, Implementation, and Evaluation of a Structured Reporting Web Tool for Abdominal Aortic Aneurysms

    PubMed Central

    Karim, Sulafa; Fegeler, Christian; Boeckler, Dittmar; H Schwartz, Lawrence; Kauczor, Hans-Ulrich

    2013-01-01

    Background The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. Objective Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. Methods Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. Results A Web-based application for radiological “structured reporting” (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. Conclusions The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems. PMID:23956062

  9. Application of Oversampling to obtain the MTF of Digital Radiology Equipment.

    NASA Astrophysics Data System (ADS)

    Narváez, M.; Graffigna, J. P.; Gómez, M. E.; Romo, R.

    2016-04-01

    Within the objectives of theproject Medical Image Processing for QualityAssessment ofX Ray Imaging, the present research work is aimed at developinga phantomX ray image and itsassociated processing algorithms in order to evaluatethe image quality rendered by digital X ray equipment. These tools are used to measure various image parameters, among which spatial resolution shows afundamental property that can be characterized by the Modulation Transfer Function (MTF)of an imaging system [1]. After performing a thorough literature surveyon imaging quality control in digital X film in Argentine and international publications, it was decided to adopt for this work the Norm IEC 62220 1:2003 that recommends using an image edge as a testingmethod. In order to obtain the characterizing MTF, a protocol was designedfor unifying the conditions under which the images are acquired for later evaluation. The protocol implied acquiring a radiography image by means of a specific referential technique, i.e. referred either to voltage, current, time, distance focus plate (/film?) distance, or other referential parameter, and to interpret the image through a system of computed radiology or direct digital radiology. The contribution of the work stems from the fact that, even though the traditional way of evaluating an X film image quality has relied mostly on subjective methods, this work presents an objective evaluative toolfor the images obtained with a givenequipment, followed by a contrastive analysis with the renderings from other X filmimaging sets.Once the images were obtained, specific calculations were carried out. Though there exist some methods based on the subjective evaluation of the quality of image, this work offers an objective evaluation of the equipment under study. Finally, we present the results obtained on different equipment.

  10. Usefulness of radiological signs of pulmonary congestion in predicting failed spontaneous breathing trials

    PubMed Central

    Antonio, Ana Carolina Peçanha; Teixeira, Cassiano; Castro, Priscylla Souza; Zanardo, Ana Paula; Gazzana, Marcelo Basso; Knorst, Marli

    2017-01-01

    ABSTRACT Objective: Inspiratory fall in intrathoracic pressure during a spontaneous breathing trial (SBT) may precipitate cardiac dysfunction and acute pulmonary edema. We aimed to determine the relationship between radiological signs of pulmonary congestion prior to an SBT and weaning outcomes. Methods: This was a post hoc analysis of a prospective cohort study involving patients in an adult medical-surgical ICU. All enrolled individuals met the eligibility criteria for liberation from mechanical ventilation. Tracheostomized subjects were excluded. The primary endpoint was SBT failure, defined as the inability to tolerate a T-piece trial for 30-120 min. An attending radiologist applied a radiological score on interpretation of digital chest X-rays performed before the SBT. Results: A total of 170 T-piece trials were carried out; SBT failure occurred in 28 trials (16.4%), and 133 subjects (78.3%) were extubated at first attempt. Radiological scores were similar between SBT-failure and SBT-success groups (median [interquartile range] = 3 [2-4] points vs. 3 [2-4] points; p = 0.15), which, according to the score criteria, represented interstitial lung congestion. The analysis of ROC curves demonstrated poor accuracy (area under the curve = 0.58) of chest x-rays findings of congestion prior to the SBT for discriminating between SBT failure and SBT success. No correlation was found between fluid balance in the 48 h preceding the SBT and radiological score results (ρ = −0.13). Conclusions: Radiological findings of pulmonary congestion should not delay SBT indication, given that they did not predict weaning failure in the medical-surgical critically ill population. (ClinicalTrials.gov identifier: NCT02022839 [http://www.clinicaltrials.gov/]) PMID:29364998

  11. Curriculum in radiology for residents: what, why, how, when, and where.

    PubMed

    Collins, J

    2000-02-01

    Developing a curriculum in chest radiology should follow the same general principles that are used when developing a curriculum in any subspecialty area of radiology. A curriculum is more than a "list of topics" with which a resident should be familiar after 4 years of training. It includes objectives and goals, content, faculty, methods, and evaluation. Numerous resources are available for those who are charged with developing a curriculum in chest radiology. In addition to faculty members in the department, whose input during development can ensure successful implementation of the curriculum, organizations (i.e., ACR, APDR, STR) already have begun to develop "model" curricula. Attending the annual meeting of the Association of American Medical Colleges is a way to meet and hear from professionals who develop and oversee curriculum development at their medical schools, and another important resource available at some medical schools is the Office of Medical Education. The faculty within such offices are uniquely qualified to assist with curriculum and faculty development, especially for those areas in which radiology faculty traditionally are less experienced, such as development of valid and reliable assessment forms and construction of behaviorally based objectives.

  12. Automated classification of radiology reports to facilitate retrospective study in radiology.

    PubMed

    Zhou, Yihua; Amundson, Per K; Yu, Fang; Kessler, Marcus M; Benzinger, Tammie L S; Wippold, Franz J

    2014-12-01

    Retrospective research is an import tool in radiology. Identifying imaging examinations appropriate for a given research question from the unstructured radiology reports is extremely useful, but labor-intensive. Using the machine learning text-mining methods implemented in LingPipe [1], we evaluated the performance of the dynamic language model (DLM) and the Naïve Bayesian (NB) classifiers in classifying radiology reports to facilitate identification of radiological examinations for research projects. The training dataset consisted of 14,325 sentences from 11,432 radiology reports randomly selected from a database of 5,104,594 reports in all disciplines of radiology. The training sentences were categorized manually into six categories (Positive, Differential, Post Treatment, Negative, Normal, and History). A 10-fold cross-validation [2] was used to evaluate the performance of the models, which were tested in classification of radiology reports for cases of sellar or suprasellar masses and colloid cysts. The average accuracies for the DLM and NB classifiers were 88.5% with 95% confidence interval (CI) of 1.9% and 85.9% with 95% CI of 2.0%, respectively. The DLM performed slightly better and was used to classify 1,397 radiology reports containing the keywords "sellar or suprasellar mass", or "colloid cyst". The DLM model produced an accuracy of 88.2% with 95% CI of 2.1% for 959 reports that contain "sellar or suprasellar mass" and an accuracy of 86.3% with 95% CI of 2.5% for 437 reports of "colloid cyst". We conclude that automated classification of radiology reports using machine learning techniques can effectively facilitate the identification of cases suitable for retrospective research.

  13. Interventional Radiology in Paediatrics.

    PubMed

    Chippington, Samantha J; Goodwin, Susie J

    2015-01-01

    As in adult practice, there is a growing role for paediatric interventional radiology expertise in the management of paediatric pathologies. This review is targeted for clinicians who may refer their patients to paediatric interventional radiology services, or who are responsible for patients who are undergoing paediatric interventional radiology procedures. The article includes a brief overview of the indications for intervention, techniques involved and the commonest complications. Although some of the procedures described are most commonly performed in a tertiary paediatric centre, many are performed in most Children's hospitals.

  14. [Interventional radiology: current problems and new directions].

    PubMed

    Santos Martín, E; Crespo Vallejo, E

    2014-01-01

    In recent years, vascular and interventional radiology has become one of the fastest growing diagnostic and therapeutic specialties. This growth has been based on a fundamental concept: performing minimally invasive procedures under imaging guidance. This attractive combination has led to the interest of professionals from other clinical specialties outside radiology in performing this type of intervention. The future of vascular and interventional radiology, although uncertain, must be linked to clinical practice and multidisciplinary teamwork. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  15. A reliable and cost effective approach for radiographic monitoring in nutritional rickets

    PubMed Central

    Gupta, V; Sharma, V; Sinha, B; Samanta, S

    2014-01-01

    Objective: Radiological scoring is particularly useful in rickets, where pre-treatment radiographical findings can reflect the disease severity and can be used to monitor the improvement. However, there is only a single radiographic scoring system for rickets developed by Thacher and, to the best of our knowledge, no study has evaluated radiographic changes in rickets based on this scoring system apart from the one done by Thacher himself. The main objective of this study is to compare and analyse the pre-treatment and post-treatment radiographic parameters in nutritional rickets with the help of Thacher's scoring technique. Methods: 176 patients with nutritional rickets were given a single intramuscular injection of vitamin D (600 000 IU) along with oral calcium (50 mg kg−1) and vitamin D (400 IU per day) until radiological resolution and followed for 1 year. Pre- and post-treatment radiological parameters were compared and analysed statistically based on Thacher's scoring system. Results: Radiological resolution was complete by 6 months. Time for radiological resolution and initial radiological score were linearly associated on regression analysis. The distal ulna was the last to heal in most cases except when the initial score was 10, when distal femur was the last to heal. Conclusion: Thacher's scoring system can effectively monitor nutritional rickets. The formula derived through linear regression has prognostic significance. Advances in knowledge: The distal femur is a better indicator in radiologically severe rickets and when resolution is delayed. Thacher's scoring is very useful for monitoring of rickets. The formula derived through linear regression can predict the expected time for radiological resolution. PMID:24593231

  16. [E-Learning in radiology; the practical use of the content management system ILIAS].

    PubMed

    Schütze, B; Mildenberger, P; Kämmerer, M

    2006-05-01

    Due to the possibility of using different kinds of visualization, e-learning has the advantage of allowing individualized learning. A check should be performed to determine whether the use of the web-based content management system ILIAS simplifies the writing and production of electronic learning modules in radiology. Internet-based e-learning provides access to existing learning modules regardless of time and location, since fast Internet connections are readily available. Web Content Management Systems (WCMS) are suitable platforms for imparting radiology-related information (visual abilities like the recognition of patterns as well as interdisciplinary specialized knowledge). The open source product ILIAS is a free WCMS. It is used by many universities and is accepted by both students and lecturers. Its modular and object-oriented software architecture makes it easy to adapt and enlarge the platform. The employment of e-learning standards such as LOM and SCORM within ILIAS makes it possible to reuse contents, even if the platform has to be changed. ILIAS renders it possible to provide students with texts, images, or files of any other kind within a learning context which is defined by the lecturer. Students can check their acquired knowledge via online testing and receive direct performance feedback. The significant interest that students have shown in ILIAS proves that e-learning can be a useful addition to conventional learning methods.

  17. Glove Perforations During Interventional Radiological Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leena, R. V., E-mail: leenarv_76@yahoo.co.uk; Shyamkumar, N. K.

    2010-04-15

    Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.

  18. Performance assessment for continuing and future operations at Solid Waste Storage Area 6

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-02-01

    This radiological performance assessment for the continued disposal operations at Solid Waste Storage Area 6 (SWSA 6) on the Oak Ridge Reservation (ORR) has been prepared to demonstrate compliance with the requirements of the US DOE. The analysis of SWSA 6 required the use of assumptions to supplement the available site data when the available data were incomplete for the purpose of analysis. Results indicate that SWSA 6 does not presently meet the performance objectives of DOE Order 5820.2A. Changes in operations and continued work on the performance assessment are expected to demonstrate compliance with the performance objectives for continuingmore » operations at the Interim Waste Management Facility (IWMF). All other disposal operations in SWSA 6 are to be discontinued as of January 1, 1994. The disposal units at which disposal operations are discontinued will be subject to CERCLA remediation, which will result in acceptable protection of the public health and safety.« less

  19. Radiology utilizing a gas multiwire detector with resolution enhancement

    DOEpatents

    Majewski, Stanislaw; Majewski, Lucasz A.

    1999-09-28

    This invention relates to a process and apparatus for obtaining filmless, radiological, digital images utilizing a gas multiwire detector. Resolution is enhanced through projection geometry. This invention further relates to imaging systems for X-ray examination of patients or objects, and is particularly suited for mammography.

  20. A Pilot Study of Contextual UMLS Indexing to Improve the Precision of Concept-based Representation in XML-structured Clinical Radiology Reports

    PubMed Central

    Huang, Yang; Lowe, Henry J.; Hersh, William R.

    2003-01-01

    Objective: Despite the advantages of structured data entry, much of the patient record is still stored as unstructured or semistructured narrative text. The issue of representing clinical document content remains problematic. The authors' prior work using an automated UMLS document indexing system has been encouraging but has been affected by the generally low indexing precision of such systems. In an effort to improve precision, the authors have developed a context-sensitive document indexing model to calculate the optimal subset of UMLS source vocabularies used to index each document section. This pilot study was performed to evaluate the utility of this indexing approach on a set of clinical radiology reports. Design: A set of clinical radiology reports that had been indexed manually using UMLS concept descriptors was indexed automatically by the SAPHIRE indexing engine. Using the data generated by this process the authors developed a system that simulated indexing, at the document section level, of the same document set using many permutations of a subset of the UMLS constituent vocabularies. Measurements: The precision and recall scores generated by simulated indexing for each permutation of two or three UMLS constituent vocabularies were determined. Results: While there was considerable variation in precision and recall values across the different subtypes of radiology reports, the overall effect of this indexing strategy using the best combination of two or three UMLS constituent vocabularies was an improvement in precision without significant impact of recall. Conclusion: In this pilot study a contextual indexing strategy improved overall precision in a set of clinical radiology reports. PMID:12925544

  1. Radiation Protection Knowledge, Attitude, and Practice (KAP) in Interventional Radiology

    PubMed Central

    Shabani, Fatemeh; Hasanzadeh, Hadi; Emadi, Alireza; Mirmohammadkhani, Majid; Bitarafan-Rajabi, Ahmad; Abedelahi, Ali; Bokharaeian, Mitra; Masoumi, Hamed; Seifi, Danial; Khani, Tahereh; Sanchooli, Mohamad; Moshfegh, Shima; Ziari, Abbas

    2018-01-01

    Objectives Due to increasing cardiac disease and its mortality rate, the frequency of cardiac imaging has grown and, as a result, interventional cardiologists potentially receive high radiation doses in cardiac examinations. This study aimed to assess the knowledge, attitude, and practice (KAP) level of radiation protection (RP) among interventional radiology staff in Iranian health care centers across the country. Methods We used a validated questionnaire survey consisting of 30 multiple-choice questions to perform a cross-sectional study. Participants were healthcare personnel working professionally with radiation at different levels (i.e., secretary, radiology technologists, nurse, and physician). The questionnaire was divided into three sections to assess KAP regarding RP. Results Significant differences exist in RP KAP mean scores based on educational age (p < 0.050). There was no significant difference in RP KAP mean scores when looking at sex, practice age, and hospital type (p > 0.050). We found a significant difference between RP KAP mean scores and different regions (p < 0.050). Conclusions Educational and practice age, sex, type of hospital, and geographical region affect he KAP of interventional radiology staff regarding RP. Since many of the subjective radiation harms for both medical team and patients, this can be easily controlled and prevented; a checkup for personnel of interventional radiology departments, considering samples from different parts of the country with different levels of education, continuous training, and practical courses may help map the status of KAP. The results of this study may also help authorized health physics officers design strategic plans to enhance the quality of such services in radiation departments. PMID:29657683

  2. Pedagogical Approaches to Diagnostic Imaging Education: A Narrative Review of the Literature

    PubMed Central

    Linaker, Kathleen L.

    2015-01-01

    Objective The purpose of this study was to examine literature on how radiology is taught and learned by both radiology residents and undergraduates in the health professions. Methods A review of the literature was performed using relevant key words. Articles were retrieved through December 2012 using PubMed, ScienceDirect, ERIC, Proquest, and ICL databases along with a manual review of references. Results Of the 4716 unique abstracts reviewed by the author, 91 were found to be relevant to the purpose of this study. The literature retrieved reported pedagogical approaches to teaching radiology including the following: problem solving, technology as teacher, independent learning tools, visiting lectureships, case based teaching, and conferences. There was some exploration of the relative effectiveness of educational formats. Suggestions for future research identify 7 areas of relative consistency. Conclusion Radiology is a clinical skill that requires integration science, clinical information, clinical experiences, and information recorded on diagnostic imaging studies. The research in this area focuses on problem solving, the use of algorithm/scripts, introducing uncertainty in clinical scenarios, incorporating technology in learning environments, active learning techniques, and methods of independent learning. Although the literature in this area is still in its infancy, the research examining the relative effectiveness of these various educational formats is often contradictory, suggesting that this is a complex area of study with numerous factors influencing student learning. PMID:26770173

  3. Mandibular Third Molar Impaction: Review of Literature and a Proposal of a Classification

    PubMed Central

    Daugela, Povilas

    2013-01-01

    ABSTRACT Objectives The purpose of present article was to review impacted mandibular third molar aetiology, clinical anatomy, radiologic examination, surgical treatment and possible complications, as well as to create new mandibular third molar impaction and extraction difficulty degree classification based on anatomical and radiologic findings and literature review results. Material and Methods Literature was selected through a search of PubMed, Embase and Cochrane electronic databases. The keywords used for search were mandibular third molar, impacted mandibular third molar, inferior alveolar nerve injury third molar, lingual nerve injury third molar. The search was restricted to English language articles, published from 1976 to April 2013. Additionally, a manual search in the major anatomy and oral surgery journals and books was performed. The publications there selected by including clinical and human anatomy studies. Results In total 75 literature sources were obtained and reviewed. Impacted mandibular third molar aetiology, clinical anatomy, radiographic examination, surgical extraction of and possible complications, classifications and risk factors were discussed. New mandibular third molar impaction and extraction difficulty degree classification based on anatomical and radiologic findings and literature review results was proposed. Conclusions The classification proposed here based on anatomical and radiological impacted mandibular third molar features is promising to be a helpful tool for impacted tooth assessment as well as for planning for surgical operation. Further clinical studies should be conducted for new classification validation and reliability evaluation. PMID:24422029

  4. Introductory lecture series for first-year radiology residents: implementation, investment and assessment.

    PubMed

    Chapman, Teresa; Chew, Felix S

    2013-03-01

    A lecture series aimed at providing new radiology residents a rapid course on the fundamental concepts of professionalism, safety, and interpretation of diagnostic imaging was established. Evaluation of the course's educational value was attempted through surveys. Twenty-six live 45-minute lectures presented by 16 or 17 faculty members were organized exclusively for the first class of radiology residents, held over a 2-month period at the beginning of certain weekdays. Online surveys were conducted after the course to gather feedback from residents. Average resident rotation evaluation scores were measured over the first semester for the two classes before and after this new course implementation. The lecture series was successfully organized and implemented. A total of 33 residents sat through the course over three summers. Faculty reported a reasonable number of preparation hours, and 100% of residents indicated they valued the course. Comparison of class average evaluation scores before and after the existence of this 2-month course did not significantly change. This collection of introductory lectures on professionalism, safety, and diagnostic imaging, delivered early in the first year of the radiology residency, requires a reasonable number of invested preparation hours by the faculty but results in a universal increase in resident confidence. However, we were unable to demonstrate an objective improvement in resident performance on clinical rotations. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  5. RADIOPROTECTION CAMPAIGN AND CARD: EDUCATIONAL STRATEGIES THAT REDUCE CHILDREN'S EXCESSIVE EXPOSURE TO RADIOLOGICAL EXAMS.

    PubMed

    Bernardo, Mônica Oliveira; Almeida, Fernando Antonio de; Morgado, Flavio

    2017-01-01

    To analyze the results of an initiative aimed at improving the reasonable use of radiological examinations, ensuring their technical quality, implementing a radioprotection campaign that includes training of the professional team, and introducing the radioprotection card for children under 12 years old as a tool for parents and doctors to control children's exposure to radiation. The study was held in a health care insurance system covering 140,000 people. A radioprotection campaign was implemented according to Image Gently • protocols, ensuring the lowest dose of radiation and the quality of examinations, and the radioprotection card was implemented. To assess the effectiveness of these actions, the number of radiological examinations performed at the pediatric emergency room in a period of one year preceding the campaign was compared with the number of radiological examinations performed one year after the campaign. The campaign was well accepted by all professionals, families, and patients involved. In the year following the implementation of radioprotection strategies, there was a 22% reduction of radiological examinations performed at the pediatric emergency room. There was also a 29% reduction in the request of two or more radiological examinations for the same child or examinations with two or more incidences. The campaign and the radioprotection card for children under 12 years old proved to be feasible strategies and correlated with a reduction in radiological examinations requested and performed at the pediatric emergency room.

  6. TH-E-201-00: Teaching Radiology Residents: What, How, and Expectation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program.more » The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant.« less

  7. TH-E-201-01: Diagnostic Radiology Residents Physics Curriculum and Updates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sensakovic, W.

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program.more » The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant.« less

  8. Radioactive Waste Management Complex low-level waste radiological performance assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maheras, S.J.; Rood, A.S.; Magnuson, S.O.

    This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsitemore » receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected.« less

  9. A Novel Method for Quick Assessment of Internal And External Radiation Exposure in the Aftermath of a Large Radiological Incident.

    PubMed

    Korir, Geoffrey; Karam, P Andrew

    2018-06-11

    In the event of a significant radiological release in a major urban area where a large number of people reside, it is inevitable that radiological screening and dose assessment must be conducted. Lives may be saved if an emergency response plan and radiological screening method are established for use in such cases. Thousands to tens of thousands of people might present themselves with some levels of external contamination and/or the potential for internal contamination. Each of these individuals will require varying degrees of radiological screening, and those with a high likelihood of internal and/or external contamination will require radiological assessment to determine the need for medical attention and decontamination. This sort of radiological assessment typically requires skilled health physicists, but there are insufficient numbers of health physicists in any city to perform this function for large populations, especially since many (e.g., those at medical facilities) are likely to be engaged at their designated institutions. The aim of this paper is therefore to develop and describe the technical basis for a novel, scoring-based methodology that can be used by non-health physicists for performing radiological assessment during such radiological events.

  10. Key Performance Indicators in Radiology: You Can't Manage What You Can't Measure.

    PubMed

    Harvey, H Benjamin; Hassanzadeh, Elmira; Aran, Shima; Rosenthal, Daniel I; Thrall, James H; Abujudeh, Hani H

    2016-01-01

    Quality assurance (QA) is a fundamental component of every successful radiology operation. A radiology QA program must be able to efficiently and effectively monitor and respond to quality problems. However, as radiology QA has expanded into the depths of radiology operations, the task of defining and measuring quality has become more difficult. Key performance indicators (KPIs) are highly valuable data points and measurement tools that can be used to monitor and evaluate the quality of services provided by a radiology operation. As such, KPIs empower a radiology QA program to bridge normative understandings of health care quality with on-the-ground quality management. This review introduces the importance of KPIs in health care QA, a framework for structuring KPIs, a method to identify and tailor KPIs, and strategies to analyze and communicate KPI data that would drive process improvement. Adopting a KPI-driven QA program is both good for patient care and allows a radiology operation to demonstrate measurable value to other health care stakeholders. Copyright © 2015 Mosby, Inc. All rights reserved.

  11. Response of the REWARD detection system to the presence of a Radiological Dispersal Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luis, R.; Baptista, M.; Barros, S.

    2015-07-01

    In recent years an increased international concern has emerged about the radiological and nuclear (RN) threats associated with the illicit trafficking of nuclear and radioactive materials that could be potentially used for terrorist attacks. The objective of the REWARD (Real Time Wide Area Radiation Surveillance System) project, co-funded by the European Union 7. Framework Programme Security, consisted in building a mobile system for real time, wide area radiation surveillance, using a CdZnTe detector for gamma radiation and a neutron detector based on novel silicon technologies. The sensing unit includes a GPS system and a wireless communication interface to send themore » data remotely to a monitoring base station, where it will be analyzed in real time and correlated with historical data from the tag location, in order to generate an alarm when an abnormal situation is detected. Due to its portability and accuracy, the system will be extremely useful in many different scenarios such as nuclear terrorism, lost radioactive sources, radioactive contamination or nuclear accidents. This paper shortly introduces the REWARD detection system, depicts some terrorist threat scenarios involving radioactive sources and special nuclear materials and summarizes the simulation work undertaken during the past three years in the framework of the REWARD project. The main objective consisted in making predictions regarding the behavior of the REWARD system in the presence of a Radiological Dispersion Device (RDD), one of the reference scenarios foreseen for REWARD, using the Monte Carlo simulation program MCNP6. The reference scenario is characterized in detail, from the i) radiological protection, ii) radiation detection requirements and iii) communications points of view. Experimental tests were performed at the Fire Brigades Facilities in Rome and at the Naples Fire Brigades, and the results, which validate the simulation work, are presented and analyzed. The response of the REWARD detection system to the presence of an RDD is predicted and discussed. (authors)« less

  12. Radiological controls integrated into design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kindred, G.W.

    1995-03-01

    Radiological controls are required by law in the design of commercial nuclear power reactor facilities. These controls can be relatively minor or significant, relative to cost. To ensure that radiological controls are designed into a project, the health physicist (radiological engineer) must be involved from the beginning. This is especially true regarding keeping costs down. For every radiological engineer at a nuclear power plant there must be fifty engineers of other disciplines. The radiological engineer cannot be an expert on every discipline of engineering. However, he must be knowledgeable to the degree of how a design will impact the facilitymore » from a radiological perspective. This paper will address how to effectively perform radiological analyses with the goal of radiological controls integrated into the design package.« less

  13. An Internet-Based Radiology Course in Medical School: Comparison of Academic Performance of Students on Campus Versus Those With Absenteeism Due to Residency Interviews.

    PubMed

    Alexander, Andrew George; Deas, Deborah; Lyons, Paul Eric

    2018-05-18

    Imaging and its optimal use are imperative to the practice of medicine, yet many students don't receive a formal education in radiology. Concurrently, students look for ways to take time away from medical school for residency interviewing. Web-based instruction provides an opportunity to combine these imperatives using online modalities. A largely Web-based course in radiology during the 4th year of medical school was evaluated both for its acceptance to students who needed to be away from campus for interviews, and its effectiveness on a nationally administered standardized test. All students were placed into a structured program utilizing online videos, online modules, online textbook assignments, and live interactive online lectures. Over half of the course could be completed away from campus. The Alliance of Medical Student Educators in Radiology test exam bank was used as a final exam to evaluate medical knowledge. Positive student feedback included the freedom to travel for interviews, hands-on ultrasound training, interactive teaching sessions, and quality Web-based learning modules. Negative feedback included taking quizzes in-person, a perceived outdated online textbook, and physically shadowing hospital technicians. Most students elected to take the course during the interview months of October through January. The Alliance of Medical Student Educators in Radiology final exam results (70.5%) were not significantly different than the national cohort (70%) who took the course in-person. Test scores from students taking the course during interview travel months were not significantly different from students who took the course before (P=.30) or after (P=.34) the interview season. Students desire to learn radiology and often choose to do so when they need to be away from campus during the fall of their 4th year of study to accomplish their residency interviews. Web-based education in radiology allows students' interview traveling and radiology course objectives to be successfully met without adversely affecting the outcomes on a nationally normed examination in radiology. A curriculum that includes online content and live Web-based teleconference access to faculty can accomplish both imperatives. ©Andrew George Alexander, Deborah Deas, Paul Eric Lyons. Originally published in JMIR Medical Education (http://mededu.jmir.org), 18.05.2018.

  14. Enhance hospital performance from intellectual capital to business intelligence.

    PubMed

    Karami, Mahtab; Fatehi, Mansoor; Torabi, Mashallah; Langarizadeh, Mostafa; Rahimi, Azin; Safdari, Reza

    2013-01-01

    Business intelligence (BI) refers to technologies, tools, and practices for collecting, integrating, analyzing, and presenting large volumes of information to enable better decision making. The aim of this study is to provide a general overview of BI and its impacts on improving hospital performance. In this paper, literature is reviewed on the concept, classification, and structure of intellectual capital and BI. Research on the building of BI and its impact on the performance of hospitals are briefly summarized. Some areas in healthcare which can utilize BI benefits, including radiology, are also discussed. Used properly, BI is an effective communication tool that can enable hospitals to reach strategic goals and objectives and can also help eliminate information asymmetry.

  15. Interventional radiology procedures after pancreatic resections for pancreatic and periampullary diseases.

    PubMed

    Casadei, Riccardo; Ricci, Claudio; Giampalma, Emanuela; D'Ambra, Marielda; Taffurelli, Giovanni; Mosconi, Cristina; Golfieri, Rita; Minni, Francesco

    2014-07-28

    The use of interventional radiology has increased as the first-line management of complications after pancreatic resections. Patients in whom interventional radiology was performed were compared with those in whom interventional radiology was not performed as regards type of pancreatic resection, diagnosis, postoperative mortality and morbidity, postoperative pancreatic fistula postpancreatectomy haemorrhage, bile leakage, reoperation rate and length of hospital stay. Our aim was to evaluate the usefulness of interventional radiology in the treatment of complications after pancreatic resection. One hundred and eighty-two (62.8%) out of 290 patients experienced postoperative complications. Interventional radiology procedures were performed in 37 cases (20.3%): percutaneous drainage in 28, transhepatic biliary drainage in 8 and arterial embolisation in 3 cases. Technical success was obtained in all cases and clinical success in 75.7%. Reoperation was avoided in 86.5%. In patients with major complications, clinically relevant postoperative pancreatic fistula and bile leaks as well as those with late postpancreatectomy haemorrhage (P=0.030) and patients with postpancreatectomy haemorrhage grade C (P=0.029), interventional radiology was used (P<0.001, P<0.001 and P=0.009, respectively) significantly more frequently than in the remaining patients. The reoperation and mortality rates were similar in the two groups (P=0.885 and P=0.100, respectively) while patients treated with interventional radiology procedures had a significant longer length of hospital stay than those in the non-interventional radiology group (37.5 ± 23.4 vs. 18.7 ± 11.7 days; P<0.001). Interventional radiology procedures were useful, especially for patients with postoperative pancreatic fistulas and bile leaks in whom reoperation was very often avoided.

  16. Radioactive Waste Management Complex performance assessment: Draft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Case, M.J.; Maheras, S.J.; McKenzie-Carter, M.A.

    1990-06-01

    A radiological performance assessment of the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory was conducted to demonstrate compliance with appropriate radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the general public. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the general public via air, ground water, and food chain pathways. Projections of doses were made for both offsite receptors and individuals intruding onto the site after closure. In addition, uncertainty analyses were performed. Resultsmore » of calculations made using nominal data indicate that the radiological doses will be below appropriate radiological criteria throughout operations and after closure of the facility. Recommendations were made for future performance assessment calculations.« less

  17. Evaluation of mammography equipment performance, dose and image quality in five Latin American countries

    NASA Astrophysics Data System (ADS)

    Brandan, M.-E.; Ruiz-Trejo, C.; Caspani, C. E. M.; Fleitas, I.; de-la-Mora, R.; Miranda, A. A.; Plazas, M.-C.; Betancourt, C.-M.; Borras, C.

    2001-10-01

    Under the auspices of PAHO/WHO, a multicentric investigation is carried out in five Latin American countries. Its aim is to correlate quality indicators of radiology services with the accuracy of the radiological interpretation as determined by a panel of radiology experts. We present preliminary results from mammographic imaging facilities. Evaluation of the equipment performance and dose measurements in 21 mammographic units show that, on the average, 75% of the units comply with recommendations issued by various organizations. An independent evaluation of the quality of the clinical images show strong variations among the different radiological services.

  18. 2014 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Mike

    2015-02-01

    This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

  19. Patient-centered Radiology: Where Are We, Where Do We Want to Be, and How Do We Get There?

    PubMed

    Kemp, Jennifer L; Mahoney, Mary C; Mathews, Vincent P; Wintermark, Max; Yee, Judy; Brown, Stephen D

    2017-11-01

    Purpose The objectives of the Radiological Society of North America (RSNA) Patient-Centered Radiology Steering Committee survey were to (a) assess RSNA members' general attitudes and experiences concerning patient-centered radiology, with specific attention paid to radiologist-to-patient communication; (b) examine the members' barriers to communicating more directly with patients; and (c) explore their perceptions of how such barriers can be overcome. Materials and Methods A total of 5999 radiologists were invited by e-mail to complete an anonymous electronic survey developed by the Steering Committee and the RSNA Department of Research. Participants were asked to identify aspects of patient-centered care important to their practice, report on their interactions with patients, and share their opinions on radiologist-patient communication. Statistical analyses were performed by using the χ 2 test and analysis of variance. Results The response rate was 12% (n = 694, 109 invitations were undeliverable). Most respondents (89%, 611 of 684) agreed that promoting awareness of the role of radiology in patients' overall health care is important to how they practice. The majority (73%, 421 of 575) reported that time or workload frequently prevented them from communicating directly with patients. The majority (74%, 423 of 572) reported that a personal sense of satisfaction was likely to motivate them to communicate more directly with patients, but many commented that changes to reimbursement and compensation would help them communicate with patients more directly. Conclusion Many radiologists support the concept of communicating more directly with patients but report they are constrained by time or workload. Changes to reimbursement schemes may help mitigate these barriers to one crucial aspect of patient-centered care. © RSNA, 2017 Online supplemental material is available for this article.

  20. Summary of the proceedings of the International Forum 2017: "Position of interventional radiology within radiology".

    PubMed

    2018-04-01

    The International Forum is held once a year by the ESR and its international radiological partner societies with the aim to address and discuss selected topics of global relevance in radiology. In 2017, the issue of the position of interventional radiology (IR) within radiology was analysed. IR is expanding because of the increased patient demand for minimally invasive therapies performed under imaging guidance, and its success in improving patient outcomes, reducing in-hospital stays, reducing morbidity and mortality of treatment in many organs and organ-systems. Despite the many successes of IR, public awareness about it is quite low. IR requires specific training and, in most countries, the majority of interventional radiologists do not dedicate their time completely to IR but perform diagnostic radiology investigations as well. Turf battles in IR are common in many countries. To preserve and keep IR within radiology, it is necessary to focus more on direct and longitudinal patient care. Having beds dedicated to IR within radiology departments is very important to increase clinical involvement of interventional radiologists. IR procedures fit perfectly within "value-based healthcare", but the metrics have to be developed. • IR should stay a prominent subspecialty within radiology. • Dedicated IR training pathways are mandatory. • Measures to increase recruitment of young doctors to IR and to increase public awareness of IR are needed. • Beds dedicated to IR within radiology departments are important in order to increase clinical involvement of interventional radiologists.

  1. TH-E-201-02: Hands-On Physics Teaching of Residents in Diagnostic Radiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J.

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program.more » The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant.« less

  2. TH-E-201-03: A Radiology Resident’s Perspectives of Physics Teaching

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Key, A.

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program.more » The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant.« less

  3. Classic versus millennial medical lab anatomy.

    PubMed

    Benninger, Brion; Matsler, Nik; Delamarter, Taylor

    2014-10-01

    This study investigated the integration, implementation, and use of cadaver dissection, hospital radiology modalities, surgical tools, and AV technology during a 12-week contemporary anatomy course suggesting a millennial laboratory. The teaching of anatomy has undergone the greatest fluctuation of any of the basic sciences during the past 100 years in order to make room for the meteoric rise in molecular sciences. Classically, anatomy consisted of a 2-year methodical, horizontal, anatomy course; anatomy has now morphed into a 12-week accelerated course in a vertical curriculum, at most institutions. Surface and radiological anatomy is the language for all clinicians regardless of specialty. The objective of this study was to investigate whether integration of full-body dissection anatomy and modern hospital technology, during the anatomy laboratory, could be accomplished in a 12-week anatomy course. Literature search was conducted on anatomy text, journals, and websites regarding contemporary hospital technology integrating multiple image mediums of 37 embalmed cadavers, surgical suite tools and technology, and audio/visual technology. Surgical and radiology professionals were contracted to teach during the anatomy laboratory. Literature search revealed no contemporary studies integrating full-body dissection with hospital technology and behavior. About 37 cadavers were successfully imaged with roentograms, CT, and MRI scans. Students were in favor of the dynamic laboratory consisting of multiple activity sessions occurring simultaneously. Objectively, examination scores proved to be a positive outcome and, subjectively, feedback from students was overwhelmingly positive. Despite the surging molecular based sciences consuming much of the curricula, full-body dissection anatomy is irreplaceable regarding both surface and architectural, radiological anatomy. Radiology should not be a small adjunct to understand full-body dissection, but rather, full-body dissection aids the understanding of radiology mediums. The millennial anatomy dissection laboratory should consist of, at least, 50% radiology integration during full-body dissection. This pilot study is an example of the most comprehensive integration of full-body dissection, radiology, and hospital technology. © 2014 Wiley Periodicals, Inc.

  4. Which is the best way of performing a Micturating Cystourethrogram in children?

    PubMed

    Al-Imam, Ola Ali; Al-Nsour, Nareeman Moh'd; Al-Khulaifat, Samih

    2008-01-01

    The Micturating Cystourethrogram (MCU) is a tough and stressful examination for patients and their parents as well as the radiologists and pediatric radiology nurses. Even though, it is one of the most commonly used fluoroscopic procedures in pediatric radiology practice, there is no definite agreement as to the best way to perform it, considering that this examination results in the children receiving a high dose of radiation to the gonadal region. This review was undertaken to determine the best way to perform the MCU in modern pediatric radiology practice.

  5. Joint Probability Models of Radiology Images and Clinical Annotations

    ERIC Educational Resources Information Center

    Arnold, Corey Wells

    2009-01-01

    Radiology data, in the form of images and reports, is growing at a high rate due to the introduction of new imaging modalities, new uses of existing modalities, and the growing importance of objective image information in the diagnosis and treatment of patients. This increase has resulted in an enormous set of image data that is richly annotated…

  6. A Vertically Integrated Online Radiology Curriculum Developed as a Cognitive Apprenticeship: Impact on Student Performance and Learning.

    PubMed

    Lim-Dunham, Jennifer E; Ensminger, David C; McNulty, John A; Hoyt, Amy E; Chandrasekhar, Arcot J

    2016-02-01

    The principles of Collins' cognitive apprenticeship model were used to design a radiology curriculum in which medical students practice radiological skills using online case-based modules. The modules are embedded within clinical third-year clerkships, and students are provided with personalized feedback from the instructors. We describe the development of the vertical online radiology curriculum and evaluate its impact on student achievement and learning process using a mixed method approach. The curriculum was developed over a 2-year period. Student participation was voluntary in the first year and mandatory in the second year. For quantitative curriculum evaluation, student metrics for voluntary versus mandatory groups were assessed using independent sample t tests and variable entry method regression analysis. For qualitative analysis, responses from a survey of students about the value of the curriculum were organized into defined themes using consensus coding. Mandatory participation significantly improved (p = .001) the mean radiology examination score (82 %) compared to the voluntary group (73%), suggesting that mandatory participation had a beneficial effect on student performance. Potential preexisting differences in underlying general academic performance were accounted for by including mean basic science grades as the first variable in the regression model. The significant increase in R(2) from .16 to .28 when number of radiology cases completed was added to the original model, and the greater value of the standardized beta for this variable, suggest that the curriculum made a significant contribution to students' radiology examination scores beyond their baseline academic performance. Five dominant themes about curricular characteristics that enhanced student learning and beneficial outcomes emerged from consensus coding. These themes were (1) self-paced design, (2) receiving feedback from faculty, (3) clinical relevance of cases, (4) gaining confidence in interpreting radiological images, and (5) transfer of conceptual knowledge to actual practice. The vertically integrated online radiology curriculum can positively impact student performance and learning process in the context of the cognitive apprenticeship model. Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  7. Data Fusion for a Vision-Radiological System: a Statistical Calibration Algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Enqvist, Andreas; Koppal, Sanjeev; Riley, Phillip

    2015-07-01

    Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development of calibration algorithms for characterizing the fused sensor system as a single entity. There is an apparent need for correcting for a scene deviation from the basic inverse distance-squared law governing the detection rates even when evaluating system calibration algorithms. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked, to which the time-dependent radiological datamore » can be incorporated by means of data fusion of the two sensors' output data. (authors)« less

  8. ICRP Publication 132: Radiological Protection from Cosmic Radiation in Aviation.

    PubMed

    Lochard, J; Bartlett, D T; Rühm, W; Yasuda, H; Bottollier-Depois, J-F

    2016-06-01

    In this publication, the International Commission on Radiological Protection (ICRP) provides updated guidance on radiological protection from cosmic radiation in aviation, taking into account the current ICRP system of radiological protection, the latest available data on exposures in aviation, and experience gained worldwide in the management of exposures in aviation. The publication describes the origins of cosmic radiation, how it exposes passengers and aircraft crew, the basic radiological protection principles that apply to this existing exposure situation, and the available protective actions. For implementation of the optimisation principle, the Commission recommends a graded approach proportionate to the level of exposure that may be received by individuals. The objective is to keep the exposure of the most exposed individuals to a reasonable level. The Commission also recommends that information be disseminated to raise awareness about cosmic radiation, and to support informed decisions among concerned stakeholders.

  9. MO-DE-201-03: This course presents a review of radiologic anatomy and physiology as it applies to projection radiography, fluoroscopy, CT, MRI, U/S, and nuclear medicine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fahey, F.

    Fundamental knowledge of radiologic anatomy and physiology is critical for medical physicists. Many physicists are exposed to this topic only in graduate school, and knowledge is seldom formally evaluated or assessed after Part I of the ABR exam. Successful interactions with clinicians, including surgeons, radiologists, and oncologists requires that the medical physicist possess this knowledge. This course presents a review of radiologic anatomy and physiology as it applies to projection radiography, fluoroscopy, CT, MRI, U/S, and nuclear medicine. We will review structural anatomy, manipulation of tissue contrast, the marriage between anatomy and physiology, and explore how medical imaging exploits normalmore » and pathological processes in the body to generate contrast. Learning Objectives: Review radiologic anatomy. Examine techniques to manipulate tissue contrast in radiology. Integrate anatomy and physiology in molecular imaging.« less

  10. The Future of Mammography: Radiology Residents’ Experiences, Attitudes, and Opinions

    PubMed Central

    Baxi, Shrujal S.; Snow, Jacqueline G.; Liberman, Laura; Elkin, Elena B.

    2011-01-01

    OBJECTIVE The objective of our study was to assess the experiences and preferences of radiology residents with respect to breast imaging. MATERIALS AND METHODS We surveyed radiology residents at 26 programs in New York and New Jersey. Survey topics included plans for subspecialty training, beliefs, and attitudes toward breast imaging and breast cancer screening and the likelihood of interpreting mammography in the future. RESULTS Three hundred forty-four residents completed the survey (response rate, 62%). The length of time spent training in breast imaging varied from no dedicated time (37%) to 1–8 weeks (40%) to more than 9 weeks (23%). Most respondents (97%) agreed that mammography is important to women’s health. More than 85% of residents believed that mammography should be interpreted by breast imaging specialists. Respondents shared negative views about mammography, agreeing with statements that the field was associated with a high risk of malpractice (99%), stress (94%), and low reimbursement (68%). Respondents endorsed several positive attributes of mammography, including job availability (97%), flexible work schedules (94%), and few calls or emergencies (93%). Most radiology residents (93%) said that they were likely to pursue subspecialty training, and 7% expressed interest in breast imaging fellowships. CONCLUSION Radiology residents’ negative and positive views about mammography seem to be independent of time spent training in mammography and of future plans to pursue fellowship training in breast imaging. Systematic assessment of the plans and preferences of radiology residents can facilitate the development of strategies to attract trainees to careers in breast imaging. PMID:20489113

  11. Prospective randomized comparison of standard didactic lecture versus high-fidelity simulation for radiology resident contrast reaction management training.

    PubMed

    Wang, Carolyn L; Schopp, Jennifer G; Petscavage, Jonelle M; Paladin, Angelisa M; Richardson, Michael L; Bush, William H

    2011-06-01

    The objective of our study was to assess whether high-fidelity simulation-based training is more effective than traditional didactic lecture to train radiology residents in the management of contrast reactions. This was a prospective study of 44 radiology residents randomized into a simulation group versus a lecture group. All residents attended a contrast reaction didactic lecture. Four months later, baseline knowledge was assessed with a written test, which we refer to as the "pretest." After the pretest, the 21 residents in the lecture group attended a repeat didactic lecture and the 23 residents in the simulation group underwent high-fidelity simulation-based training with five contrast reaction scenarios. Next, all residents took a second written test, which we refer to as the "posttest." Two months after the posttest, both groups took a third written test, which we refer to as the "delayed posttest," and underwent performance testing with a high-fidelity severe contrast reaction scenario graded on predefined critical actions. There was no statistically significant difference between the simulation and lecture group pretest, immediate posttest, or delayed posttest scores. The simulation group performed better than the lecture group on the severe contrast reaction simulation scenario (p = 0.001). The simulation group reported improved comfort in identifying and managing contrast reactions and administering medications after the simulation training (p ≤ 0.04) and was more comfortable than the control group (p = 0.03), which reported no change in comfort level after the repeat didactic lecture. When compared with didactic lecture, high-fidelity simulation-based training of contrast reaction management shows equal results on written test scores but improved performance during a high-fidelity severe contrast reaction simulation scenario.

  12. Influence of physical parameters on radiation protection and image quality in intra-oral radiology

    NASA Astrophysics Data System (ADS)

    Belinato, W.; Souza, D. N.

    2011-10-01

    In the world of diagnostic imaging, radiography is an important supplementary method for dental diagnosis. In radiology, special attention must be paid to the radiological protection of patients and health professionals, and also to image quality for correct diagnosis. In Brazil, the national rules governing the operation of medical and dental radiology were specified in 1998 by the National Sanitary Surveillance Agency, complemented in 2005 by the guide "Medical radiology: security and performance of equipment." In this study, quality control tests were performed in public clinics with dental X-ray equipment in the State of Sergipe, Brazil, with consideration of the physical parameters that influence radiological protection and also the quality of images taken in intra-oral radiography. The accuracy of the exposure time was considered acceptable for equipment with digital timers. Exposure times and focal-spot size variations can lead to increased entrance dose. Increased dose has also been associated with visual processing of radiographic film, which often requires repeating the radiographic examination.

  13. Penetrating ballistic-like frontal brain injury caused by a metallic rod.

    PubMed

    Pascual, J M; Navas, M; Carrasco, R

    2009-06-01

    Penetrating non-missile intracranial injuries caused by metallic foreign bodies are very rare among the civilian population. We present a unique instance of a severe, high-energy, penetrating orbitocranial injury caused by a solid metallic rod that corresponded to the spray valve lever handle of a kitchen sink pre-rinse spray tap, which was fractured and projected at high speed for an unknown reason. To our knowledge, this is the first report of a high-energy, penetrating brain injury caused by such an object. After careful radiological evaluation of the shape and position of the foreign object, a combined right frontal craniotomy and supraorbital osteotomy was performed in order to achieve safe removal of the metal bar. Successful surgical treatment of an orbitocranial injury caused by a similar object has not previously been reported.

  14. Graduates' Transition from Study to Employment of Radiologic Technology Graduates of the Lyceum University of the Philippines--Batangas

    ERIC Educational Resources Information Center

    Valdez, Anacleta P.

    2012-01-01

    A ten-year tracer study of Radiologic Technology graduates of Lyceum of the Philippines University SY 1997-2007 using a survey-structured questionnaire was conducted to examine retrospective contribution of their education to their current work. The objectives of the study included the determination of graduates' job-placement profile; how…

  15. Chemical, Biological, Radiological, and Nuclear Consequence Management: Ways to Improve Fixed-Site Decontamination Capability

    DTIC Science & Technology

    2007-05-10

    objective is achieved through consequence management and fixed-site decontamination operations. The effectiveness of CBRN consequence management...decontamination operations. The effectiveness of CBRN consequence management and fixed-site decontamination executed in the Joint Security Area can be...when faced with Chemical, Biological, Radiological, or Nuclear (CBRN) contaminated ports of debarkation. The effectiveness of CBRN consequence

  16. Development of RAD-Score: A Tool to Assess the Procedural Competence of Diagnostic Radiology Residents.

    PubMed

    Isupov, Inga; McInnes, Matthew D F; Hamstra, Stan J; Doherty, Geoffrey; Gupta, Ashish; Peddle, Susan; Jibri, Zaid; Rakhra, Kawan; Hibbert, Rebecca M

    2017-04-01

    The purpose of this study is to develop a tool to assess the procedural competence of radiology trainees, with sources of evidence gathered from five categories to support the construct validity of tool: content, response process, internal structure, relations to other variables, and consequences. A pilot form for assessing procedural competence among radiology residents, known as the RAD-Score tool, was developed by evaluating published literature and using a modified Delphi procedure involving a group of local content experts. The pilot version of the tool was tested by seven radiology department faculty members who evaluated procedures performed by 25 residents at one institution between October 2014 and June 2015. Residents were evaluated while performing multiple procedures in both clinical and simulation settings. The main outcome measure was the percentage of residents who were considered ready to perform procedures independently, with testing conducted to determine differences between levels of training. A total of 105 forms (for 52 procedures performed in a clinical setting and 53 procedures performed in a simulation setting) were collected for a variety of procedures (eight vascular or interventional, 42 body, 12 musculoskeletal, 23 chest, and 20 breast procedures). A statistically significant difference was noted in the percentage of trainees who were rated as being ready to perform a procedure independently (in postgraduate year [PGY] 2, 12% of residents; in PGY3, 61%; in PGY4, 85%; and in PGY5, 88%; p < 0.05); this difference persisted in the clinical and simulation settings. User feedback and psychometric analysis were used to create a final version of the form. This prospective study describes the successful development of a tool for assessing the procedural competence of radiology trainees with high levels of construct validity in multiple domains. Implementation of the tool in the radiology residency curriculum is planned and can play an instrumental role in the transition to competency-based radiology training.

  17. What's New in 10 Years? A Revised Cardiothoracic Curriculum for Diagnostic Radiology Residency with Goals and Objectives Related to General Competencies.

    PubMed

    Nguyen, Elsie T; Ackman, Jeanne B; Rajiah, Prabhakar; Little, Brent; Wu, Carol; Bueno, Juliana M; Gilman, Mathew D; Christensen, Jared D; Madan, Rachna; Laroia, Archana T; Lee, Christopher; Kanne, Jeffrey P; Collins, Jannette

    2016-07-01

    This is a cardiothoracic curriculum document for radiology residents meant to serve not only as a study guide for radiology residents but also as a teaching and curriculum reference for radiology educators and radiology residency program directors. This document represents a revision of a cardiothoracic radiology resident curriculum that was published 10 years ago in Academic Radiology. The sections that have been significantly revised, expanded, or added are (1) lung cancer screening, (2) lung cancer genomic profiling, (3) lung adenocarcinoma revised nomenclature, (4) lung biopsy technique, (5) nonvascular thoracic magnetic resonance, (6) updates to the idiopathic interstitial pneumonias, (7) cardiac computed tomography updates, (8) cardiac magnetic resonance updates, and (9) new and emerging techniques in cardiothoracic imaging. This curriculum was written and endorsed by the Education Committee of the Society of Thoracic Radiology. This curriculum operates in conjunction with the Accreditation Council for Graduate Medical Education (ACGME) milestones project that serves as a framework for semiannual evaluation of resident physicians as they progress through their training in an ACGME-accredited residency or fellowship programs. This cardiothoracic curriculum document is meant to serve not only as a more detailed guide for radiology trainees, educators, and program directors but also complementary to and guided by the ACGME milestones. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  18. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games.

    PubMed

    Bethapudi, Sarath; Ritchie, David; Bongale, Santosh; Gordon, Jonny; MacLean, John; Mendl, Liz

    2015-10-01

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9% were magnetic resonance imaging (MRI) scans, 22% were diagnostic ultrasound (US) examinations, 33.1% were radiographs, 4.3% were computed tomography (CT) scans and 2.7% were imaging-guided interventional procedures. 88% of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events.

  19. Manned space flight nuclear system safety. Volume 6: Space base nuclear system safety plan

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A qualitative identification of the steps required to assure the incorporation of radiological system safety principles and objectives into all phases of a manned space base program are presented. Specific areas of emphasis include: (1) radiological program management, (2) nuclear system safety plan implementation, (3) impact on program, and (4) summary of the key operation and design guidelines and requirements. The plan clearly indicates the necessity of considering and implementing radiological system safety recommendations as early as possible in the development cycle to assure maximum safety and minimize the impact on design and mission plans.

  20. CONFIRMATORY SURVEY OF THE DEFENSE LOGISTICS AGENCY, DEFENSE NATIONAL STOCKPILE CENTER NEW HAVEN DEPOT, NEW HAVEN, INDIANA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    E.M. Harpenau

    2010-02-19

    The objectives of the radiological confirmatory survey were to collect adequate radiological data for use in evaluating the radiological condition of NHD land areas, warehouses, and support buildings. The data generated from the confirmatory survey activities were used to evaluate the results of the Final Status Survey Report (FSSR) submitted by Cabrera Services (Cabrera 2009). Cabrera has stated that all radioactive materials have been removed and that remediation of the open land areas and structure surfaces was complete, and that the NHD meets the criteria for unrestricted use.

  1. Common procedures and strategies for anaesthesia in interventional radiology.

    PubMed

    Landrigan-Ossar, Mary

    2015-08-01

    This review describes the range of cases now available in the interventional radiology suite and summarizes suggestions for their anaesthetic and perioperative management. The type and complexity of interventional radiology cases being performed increases from year to year. Anaesthesiologists' presence in interventional radiology is increasing in turn, due to increasingly ill patients and intricate procedures requiring more than local anaesthesia for well tolerated completion. The literature available describing this is largely written by radiologists, with little attention paid to anaesthetic considerations. Cases in interventional radiology are complex in terms of the logistics of working in an unfamiliar area, frequency of patient comorbidity and unfamiliar procedures. Ensuring familiarity with the variety of interventional radiology procedures and their periprocedure requirements can increase anaesthesiologists' comfort in interventional radiology.

  2. Radiological Monitoring Results for Groundwater Samples Associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Pond: November 1, 2011-October 31, 2012

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mike lewis

    2013-02-01

    This report summarizes radiological monitoring performed on samples from specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond WRU-I-0160-01, Modification 1 (formerly LA-000160-01). The radiological monitoring was performed to fulfill Department of Energy requirements under the Atomic Energy Act.

  3. Radiological Monitoring Results for Groundwater Samples Associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Pond: November 1, 2012-October 31, 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mike Lewis

    2014-02-01

    This report summarizes radiological monitoring performed on samples from specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond WRU-I-0160-01, Modification 1 (formerly LA-000160-01). The radiological monitoring was performed to fulfill Department of Energy requirements under the Atomic Energy Act.

  4. [Radiologic picture of maxillary sinus aspergilloma].

    PubMed

    Kaczmarek, I; Bilska, J; Osmola, K; Nowaczyk, M T

    2010-06-01

    Mycotic infection of paranasal sinus could be the etiological factor of chronic sinusitis. The increase in number of fungal sinusitis cases have been reported recently among nonimmunocompromised patient after endodontic treatment of maxillary teeth. Nonspecific clinical signs and incorrect radiologic pictures interpretation as well as loss of therapeutic standards seems to be the cause of false negative diagnosis and difficulties in treatment of fungal sinusitis. Clinical and radiological picture of maxillary sinus aspergillosis was described in this paper. In the period of 2006-2009 in the Department of Maxillo-Facial Surgery 19 patient with fungal maxillary sinusitis was treated. The endodontic treatment of maxillary teeth of the related side was performed previously in 80% examined cases. In 2 cases there were immunocompromised patients with immunosuppressive treatment. In 16 cases patients were referred to our Department due to metallic foreign body of the maxillary sinus. Routine diagnostic radiological imaging was performed in each case: paranasal sinus view--Water's view and panoramic radiograph (orthopantomograph). In 4 cases imaging was extended with computer tomography (CT) visualization. The surgical treatment was performed in each case. The final diagnosis was puted on histopathological examination and fungal culture. In 16 cases of analysed group histopathological examination and fungal culture revealed aspergilosis. In 2 cases fungal culture was negative, but histopathology slices confirm presence of hyphae of Aspergillus. In 1 case the root canal sealer was found in the maxillary sinus. In none case invasive form of aspergillosis was confirmed. In all cases Water's view of paranasal sinuses and ortopantomograph showed partially or totally clouded sinus with well-defined, single or multifocal radiopaque object similar to metallic foreign body. Characteristic finding in CT imaging was well-defined radiodence concretions that have been attributed to calcium deposits in inflammatory changed mucosa, that might suggest "foreign body" picture. In 1 to 3 years follow-up control there was a recurrence of symptoms in one case. Foreign body of maxillary sinus have to be differentiated with aspergilosis. Metallic "foreign body" view in maxillary sinus seems to be characteristic sign of aspergillosis. The most often form of maxillary sinus aspergilosis is aspergilloma.

  5. Incorporating intelligence into structured radiology reports

    NASA Astrophysics Data System (ADS)

    Kahn, Charles E.

    2014-03-01

    The new standard for radiology reporting templates being developed through the Integrating the Healthcare Enterprise (IHE) and DICOM organizations defines the storage and exchange of reporting templates as Hypertext Markup Language version 5 (HTML5) documents. The use of HTML5 enables the incorporation of "dynamic HTML," in which documents can be altered in response to their content. HTML5 documents can employ JavaScript, the HTML Document Object Model (DOM), and external web services to create intelligent reporting templates. Several reporting templates were created to demonstrate the use of scripts to perform in-template calculations and decision support. For example, a template for adrenal CT was created to compute contrast washout percentage from input values of precontrast, dynamic postcontrast, and delayed adrenal nodule attenuation values; the washout value can used to classify an adrenal nodule as a benign cortical adenoma. Dynamic templates were developed to compute volumes and apply diagnostic criteria, such as those for determination of internal carotid artery stenosis. Although reporting systems need not use a web browser to render the templates or their contents, the use of JavaScript creates innumerable opportunities to construct highly sophisticated HTML5 reporting templates. This report demonstrates the ability to incorporate dynamic content to enhance the use of radiology reporting templates.

  6. A general natural-language text processor for clinical radiology.

    PubMed Central

    Friedman, C; Alderson, P O; Austin, J H; Cimino, J J; Johnson, S B

    1994-01-01

    OBJECTIVE: Development of a general natural-language processor that identifies clinical information in narrative reports and maps that information into a structured representation containing clinical terms. DESIGN: The natural-language processor provides three phases of processing, all of which are driven by different knowledge sources. The first phase performs the parsing. It identifies the structure of the text through use of a grammar that defines semantic patterns and a target form. The second phase, regularization, standardizes the terms in the initial target structure via a compositional mapping of multi-word phrases. The third phase, encoding, maps the terms to a controlled vocabulary. Radiology is the test domain for the processor and the target structure is a formal model for representing clinical information in that domain. MEASUREMENTS: The impression sections of 230 radiology reports were encoded by the processor. Results of an automated query of the resultant database for the occurrences of four diseases were compared with the analysis of a panel of three physicians to determine recall and precision. RESULTS: Without training specific to the four diseases, recall and precision of the system (combined effect of the processor and query generator) were 70% and 87%. Training of the query component increased recall to 85% without changing precision. PMID:7719797

  7. Validation of the Proficiency Examination for Diagnostic Radiologic Technology. Final Report.

    ERIC Educational Resources Information Center

    Educational Testing Service, Princeton, NJ.

    The validity of the Proficiency Examination for Diagnostic Radiologic Technology was investigated, using 140 radiologic technologists who took both the written Proficiency Examination and a performance test. As an additional criterion measure of job proficiency, supervisors' assessments were obtained for 128 of the technologists. The resulting…

  8. 42 CFR 402.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... physician. Radiologist service means radiology services performed only by, or under the direction of, a physician who is certified, or eligible to be certified, by the American Board of Radiology or for whom radiology services account for at least 50 percent of the total amount of charges made under part B of title...

  9. Clinical and radiological outcomes after a quasi-anatomical reconstruction of medial patellofemoral ligament with gracilis tendon autograft.

    PubMed

    Monllau, Joan C; Masferrer-Pino, Àngel; Ginovart, Gerard; Pérez-Prieto, Daniel; Gelber, Pablo E; Sanchis-Alfonso, Vicente

    2017-08-01

    To analyse the clinical and radiological outcomes of a quasi-anatomical reconstruction of the medial patellofemoral ligament (MPFL) with a gracilis tendon autograft. Patients with objective recurrent patellar instability that were operated on from 2006 to 2012 were included. A quasi-anatomical surgical technique was performed using a gracilis tendon autograft. It was anatomically attached at the patella, and the adductor magnus tendon was also used as a pulley for femoral fixation (non-anatomical reconstruction). The IKDC, Kujala and Lysholm scores as well as Tegner and VAS for pain were collected preoperatively and at final follow-up. Radiographic measurements of patellar position tilt and signs of osteoarthritis (OA) as well as trochlear dysplasia were also recorded. Thirty-six patients were included. The mean age at surgery was 25.6 years. After a minimum 27 months of follow-up, all functional scores significantly improved (p < 0.001) with respect to the preoperative values. The VAS dropped from 6 (SD 2.48) to 2 (SD 1.58). No recurrence of dislocation was observed in this series. The apprehension sign was still apparent in one patient. The CT scan evaluation showed a significant decrease in patellar tilt (p < 0.001). On the Crosby and Insall grading scale, there were no changes in the radiological signs of OA. This specific MPFL reconstruction gives good clinical results and corrects patellar tilt. It did not affect the patellofemoral surfaces at the short term, as shown by the absence of radiological signs of OA in the CT scan. The procedure has been shown to be safe and suitable for the treatment of chronic patellar instability, including in adolescents with open physis. A new effective, inexpensive and easy-to-perform technique is described to reconstruct MPFL in the daily clinical practice. Therapeutic case series, Level IV.

  10. Radiological study to evaluate the spreading of two volumes (10 vs. 20ml) of radiological contrast in the block of cutaneous branches of intercostal nerves in medial axillary line (BRILMA) in a porcine experimental model.

    PubMed

    Varela, O; Melone, A; López-Menchaca, R; Sevilla, R; Callejo, D; López-Álvarez, S; Román Fernández, A; García, S; Mantilla, I; Zaballos, M

    2018-06-07

    Interfascial blocks of the thoracic wall are being developed as an alternative to central blocks in breast surgery. However, there are few studies that have evaluated the anatomical extension of the local anaesthetic. The objective of this study was to analyse, using fluoroscopy, the spreading of two volumes (10 vs. 20ml) of radiological contrast in the serratus-intercostal plane block in an experimental pig model. Ten Large-White breed pigs were selected to have a bilateral ultrasound serratus-intercostal plane block performed, with the administering of 10ml and 20ml of iopamidol in the right and left hemithorax, respectively. The spreading of contrast was analysed by fluoroscopy. The Spearman test correlation was used to evaluate the relationship between the administered volume and radiological spreading. A value of P<.05 was considered significant. Twenty anaesthetic blocks were performed, being able to analyse 18 of them. The administration of 10ml of contrast was associated with a mean spreading of 2.28±0.31 (95% CI; 2.01-2.54) intercostal spaces, while the administration of 20ml showed a spreading of 3±0.25 (95% CI; 2.81-3.18) intercostal spaces. There was a significant correlation between the injected volume and the spreading of the contrast (Spearman correlation coefficient of 0.81; P=.0001). The results showed a spreading of volume subject to the serratus-intercostal plane block, although not maintaining a 1:1 ratio. Doubling the volume increased the blocked segments by 31%. These findings, if corroborated in the clinical practice, would allow a more precise adjustment in the anaesthetic volume administered. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Associations Between NIH Funding and Advanced Bibliometric Indices Among Radiological Investigators.

    PubMed

    Rosenkrantz, Andrew B; Jiang, Anthony

    2016-06-01

    Whereas data support the h index (reflecting both publications and citations) as an indicator of academic productivity, other advanced bibliometric indices aiming to address shortcomings of the h index remain poorly studied. Our objective was to compare the associations between bibliometric indices and total National Institutes of Health (NIH) grant funding among investigators within U.S. academic radiology departments. NIH grant funding amounts for 400 NIH-funded investigators within radiology departments were obtained from Blue Ridge Institute for Medical Research. Investigators' publications and associated citations were identified using Scopus. Indices computed for each investigator included: publication count, citation count, h index, i-10 index, hc index (h index adjusted for recency of publications), m quotient (h index adjusted for career duration), and e index and g index (both account for highly cited articles). Spearman correlations were performed between indices and funding. Multivariable linear regression was performed to identify significant independent predictors of funding. For MD investigators: the indices exhibited no-to-weak correlations with funding (r = 0.173-0.387); m quotient exhibited the largest correlation and was the only significant (albeit weak) independent predictor of funding (P = 0.011). For PhD investigators: correlation with funding was weak for m quotient (r = 0.323), although moderate for other indices (r = 0.518-0.568); publication count exhibited highest correlation; publication count (P < 0.001) and hc index (P = 0.024) were significant independent predictors of funding. Bibliometric indices were more strongly associated with grant funding for PhD than for MD radiology investigators, with publication count exhibiting the strongest association in the latter group. Time-weighted adjustments, as reflected by the m quotient and hc index, may improve efforts to predict funding using bibliometrics. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  12. Radiology workstation design for the medical intensive care unit.

    PubMed

    Moise, Adrian; Atkins, Stella M

    2002-01-01

    The "one-size-fits-all" approach for radiology workstation design is not good enough anymore. While most of the picture archiving and communication system (PACS) vendors are racing to add more features to the radiology workstation, there is little interest in addressing the specific needs of other hospital departments. Significant delays in the availability of radiology reports are often caused by the fact there is not enough Intensive Care Unit (ICU) volume to justify a full time radiologist. Consequently, the radiologist assigned to cover the ICU exams, most likely working from a different building, will read the ICU exams only at certain times, depending on the limitations for remote image availability. This paper addresses the main objectives in designing a digital radiology workstation for use in the medical ICU (MICU), requiring enhancements to current PACS systems. Our suggestions for PACS improvement follow the ICU digital workflow starting with the transfer of the images from the modality, continuing with the presentation of the radiology examination to different types of users (radiologists or ICU staff), up to the creation and distribution of the reports.

  13. Resources planning for radiological incidents management

    NASA Astrophysics Data System (ADS)

    Hamid, Amy Hamijah binti Ab.; Rozan, Mohd Zaidi Abd; Ibrahim, Roliana; Deris, Safaai; Yunus, Muhd. Noor Muhd.

    2017-01-01

    Disastrous radiation and nuclear meltdown require an intricate scale of emergency health and social care capacity planning framework. In Malaysia, multiple agencies are responsible for implementing radiological and nuclear safety and security. This research project focused on the Radiological Trauma Triage (RTT) System. This system applies patient's classification based on their injury and level of radiation sickness. This classification prioritizes on the diagnostic and treatment of the casualties which include resources estimation of the medical delivery system supply and demand. Also, this system consists of the leading rescue agency organization and disaster coordinator, as well as the technical support and radiological medical response teams. This research implemented and developed the resources planning simulator for radiological incidents management. The objective of the simulator is to assist the authorities in planning their resources while managing the radiological incidents within the Internal Treatment Area (ITA), Reception Area Treatment (RAT) and Hospital Care Treatment (HCT) phases. The majority (75%) of the stakeholders and experts, who had been interviewed, witnessed and accepted that the simulator would be effective to resolve various types of disaster and resources management issues.

  14. Combination of radiological and gray level co-occurrence matrix textural features used to distinguish solitary pulmonary nodules by computed tomography.

    PubMed

    Wu, Haifeng; Sun, Tao; Wang, Jingjing; Li, Xia; Wang, Wei; Huo, Da; Lv, Pingxin; He, Wen; Wang, Keyang; Guo, Xiuhua

    2013-08-01

    The objective of this study was to investigate the method of the combination of radiological and textural features for the differentiation of malignant from benign solitary pulmonary nodules by computed tomography. Features including 13 gray level co-occurrence matrix textural features and 12 radiological features were extracted from 2,117 CT slices, which came from 202 (116 malignant and 86 benign) patients. Lasso-type regularization to a nonlinear regression model was applied to select predictive features and a BP artificial neural network was used to build the diagnostic model. Eight radiological and two textural features were obtained after the Lasso-type regularization procedure. Twelve radiological features alone could reach an area under the ROC curve (AUC) of 0.84 in differentiating between malignant and benign lesions. The 10 selected characters improved the AUC to 0.91. The evaluation results showed that the method of selecting radiological and textural features appears to yield more effective in the distinction of malignant from benign solitary pulmonary nodules by computed tomography.

  15. Work plan for the radiological survey for the David Witherspoon, Incorporated, Landfill-1630 site, Knoxville, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-07-01

    This work plan establishes the methods and requirements for performing a radiological survey at the David Witherspoon, Incorporated, Landfill-1630 Site, Knoxville, Tennessee (DWI 1630 Site) in accordance with requirements under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The radiological survey will identify the radiological contamination level of the equipment and debris stored at the DWI 1630 Site. The data generated from the survey activities will support the decisions for characterization of the equipment/debris and aid in subsequent disposition and waste handling. The survey activities to be performed under this work plan include an equipment radiological survey,more » a walkover survey, and an immunoassay testing for polychlorinated biphenyls (PCBs). This work plan includes a quality assurance (QA)/quality control (QC) project plan, a health and safety (H&S) plan, and a waste management plan.« less

  16. Telemedicine and pediatric radiology: a new environment for training, learning, and interactive discussions.

    PubMed

    Monteiro, Alexandra M V; Corrêa, Diogo Goulart; Santos, Alair Augusto Sarmet M D; Cavalcanti, Silvio A; Sakuno, Telma; Filgueiras, Tereza; Just, Eduardo; Santos, Munique; Messina, Luiz Ary; Haddad, Ana Estela; Marchiori, Edson

    2011-12-01

    To report the experience of the Brazilian Program of Pediatric Teleradiology in combining teleconferencing and a virtual learning environment for services integration, collaborative research, and continuing education in pediatric radiology. We performed virtual meetings from March 2005 to October 2010 on pediatric radiology-related themes, using a combination of videoconferences and Web conferences, which were recorded and made available in an open-source software (Moodle) for reuse. We performed 58 virtual sessions: 29 anatomical-clinical-radiological sessions, 28 on upgrading themes, and 1 virtual symposium. The average of connected points was 12 by videoconference and 39 by Web conference, and of 450 participants per event. At the time of this writing, 318 physicians and students are registered in the virtual learning environment, with a total of 14,678 accesses. Telemedicine is being included in pediatric radiology practice, as a means for distance education, training, and continuing integration between groups.

  17. A Business Analytics Software Tool for Monitoring and Predicting Radiology Throughput Performance.

    PubMed

    Jones, Stephen; Cournane, Seán; Sheehy, Niall; Hederman, Lucy

    2016-12-01

    Business analytics (BA) is increasingly being utilised by radiology departments to analyse and present data. It encompasses statistical analysis, forecasting and predictive modelling and is used as an umbrella term for decision support and business intelligence systems. The primary aim of this study was to determine whether utilising BA technologies could contribute towards improved decision support and resource management within radiology departments. A set of information technology requirements were identified with key stakeholders, and a prototype BA software tool was designed, developed and implemented. A qualitative evaluation of the tool was carried out through a series of semi-structured interviews with key stakeholders. Feedback was collated, and emergent themes were identified. The results indicated that BA software applications can provide visibility of radiology performance data across all time horizons. The study demonstrated that the tool could potentially assist with improving operational efficiencies and management of radiology resources.

  18. Virtual Raters for Reproducible and Objective Assessments in Radiology

    NASA Astrophysics Data System (ADS)

    Kleesiek, Jens; Petersen, Jens; Döring, Markus; Maier-Hein, Klaus; Köthe, Ullrich; Wick, Wolfgang; Hamprecht, Fred A.; Bendszus, Martin; Biller, Armin

    2016-04-01

    Volumetric measurements in radiologic images are important for monitoring tumor growth and treatment response. To make these more reproducible and objective we introduce the concept of virtual raters (VRs). A virtual rater is obtained by combining knowledge of machine-learning algorithms trained with past annotations of multiple human raters with the instantaneous rating of one human expert. Thus, he is virtually guided by several experts. To evaluate the approach we perform experiments with multi-channel magnetic resonance imaging (MRI) data sets. Next to gross tumor volume (GTV) we also investigate subcategories like edema, contrast-enhancing and non-enhancing tumor. The first data set consists of N = 71 longitudinal follow-up scans of 15 patients suffering from glioblastoma (GB). The second data set comprises N = 30 scans of low- and high-grade gliomas. For comparison we computed Pearson Correlation, Intra-class Correlation Coefficient (ICC) and Dice score. Virtual raters always lead to an improvement w.r.t. inter- and intra-rater agreement. Comparing the 2D Response Assessment in Neuro-Oncology (RANO) measurements to the volumetric measurements of the virtual raters results in one-third of the cases in a deviating rating. Hence, we believe that our approach will have an impact on the evaluation of clinical studies as well as on routine imaging diagnostics.

  19. Creating a comprehensive customer service program to help convey critical and acute results of radiology studies.

    PubMed

    Towbin, Alexander J; Hall, Seth; Moskovitz, Jay; Johnson, Neil D; Donnelly, Lane F

    2011-01-01

    Communication of acute or critical results between the radiology department and referring clinicians has been a deficiency of many radiology departments. The failure to perform or document these communications can lead to poor patient care, patient safety issues, medical-legal issues, and complaints from referring clinicians. To mitigate these factors, a communication and documentation tool was created and incorporated into our departmental customer service program. This article will describe the implementation of a comprehensive customer service program in a hospital-based radiology department. A comprehensive customer service program was created in the radiology department. Customer service representatives were hired to answer the telephone calls to the radiology reading rooms and to help convey radiology results. The radiologists, referring clinicians, and customer service representatives were then linked via a novel workflow management system. This workflow management system provided tools to help facilitate the communication needs of each group. The number of studies with results conveyed was recorded from the implementation of the workflow management system. Between the implementation of the workflow management system on August 1, 2005, and June 1, 2009, 116,844 radiology results were conveyed to the referring clinicians and documented in the system. This accounts for more than 14% of the 828,516 radiology cases performed in this time frame. We have been successful in creating a comprehensive customer service program to convey and document communication of radiology results. This program has been widely used by the ordering clinicians as well as radiologists since its inception.

  20. Comparison of the Ministry of Health’s tariffs with the cost of radiology services using the activity-based costing method

    PubMed Central

    Kalhor, Rohollah; Amini, Saeed; Emami, Majid; Kakasoltani, Keivan; Rhamani, Nasim; Kalhor, Leila

    2016-01-01

    Introduction Efficient use of resources in organizations is one of the most important duties of managers. Appropriate allocation of resources can help managers to do this well. The aim of this study was to determine the cost of radiology services and to compare it with governmental tariffs (introduced by the Ministry of Health in Iran). Methods This was a descriptive and applied study that was conducted using the retrospective approach. First, activity centers were identified on the basis of five main groups of hospital activities. Then, resources and resource drivers, activities, and hospital activity drivers were identified. At the next step, the activities related to the delivery of radiology process were identified. Last, through allocation of activities cost to the cost objects, the cost price of 66 services that were delivered in the radiology department were calculated. The data were collected by making checklists, using the hospital’s information system, observations, and interviews. Finally, the data were analyzed using the non-parametric Wilcoxon test, Microsoft Excel, and SPSS software, version 18. Results The findings showed that from the total cost of wages, materials, and overhead obtained, the unit cost of the 66 cost objects (delivered services) in the Radiology Department were calculated using the ABC method (Price of each unit of Nephrostogram obtained $15.8 and Cystogram obtained $18.4). The Kolmogorov-Smirnov test indicated that the distribution of data of cost price using the ABC method was not normal (p = 0.000). The Wilcoxon test showed that there was a significant difference between the cost of services and the tariff of radiology services (p = 0.000). Conclusions The cost of delivered services in radiology departments was significantly higher than approved tariffs of the Ministry of Health, which can have a negative impact on the quality of services. PMID:27054013

  1. Comparison of the Ministry of Health's tariffs with the cost of radiology services using the activity-based costing method.

    PubMed

    Kalhor, Rohollah; Amini, Saeed; Emami, Majid; Kakasoltani, Keivan; Rhamani, Nasim; Kalhor, Leila

    2016-02-01

    Efficient use of resources in organizations is one of the most important duties of managers. Appropriate allocation of resources can help managers to do this well. The aim of this study was to determine the cost of radiology services and to compare it with governmental tariffs (introduced by the Ministry of Health in Iran). This was a descriptive and applied study that was conducted using the retrospective approach. First, activity centers were identified on the basis of five main groups of hospital activities. Then, resources and resource drivers, activities, and hospital activity drivers were identified. At the next step, the activities related to the delivery of radiology process were identified. Last, through allocation of activities cost to the cost objects, the cost price of 66 services that were delivered in the radiology department were calculated. The data were collected by making checklists, using the hospital's information system, observations, and interviews. Finally, the data were analyzed using the non-parametric Wilcoxon test, Microsoft Excel, and SPSS software, version 18. The findings showed that from the total cost of wages, materials, and overhead obtained, the unit cost of the 66 cost objects (delivered services) in the Radiology Department were calculated using the ABC method (Price of each unit of Nephrostogram obtained $15.8 and Cystogram obtained $18.4). The Kolmogorov-Smirnov test indicated that the distribution of data of cost price using the ABC method was not normal (p = 0.000). The Wilcoxon test showed that there was a significant difference between the cost of services and the tariff of radiology services (p = 0.000). The cost of delivered services in radiology departments was significantly higher than approved tariffs of the Ministry of Health, which can have a negative impact on the quality of services.

  2. Two-Phase Helical Computed Tomography Study of Salivary Gland Warthin Tumors: A Radiologic Findings and Surgical Applications

    PubMed Central

    Joo, Yeon Hee; Kim, Jin Pyeong; Park, Jung Je

    2014-01-01

    Objectives The goal of this study was to define the radiologic characteristics of two-phase computed tomography (CT) of salivary gland Warthin tumors and to compare them to pleomorphic adenomas. We also aimed to provide a foundation for selecting a surgical method on the basis of radiologic findings. Methods We prospectively enrolled 116 patients with parotid gland tumors, who underwent two-phase CT preoperatively. Early and delayed phase scans were obtained, with scanning delays of 30 and 120 seconds, respectively. The attenuation changes and enhancement patterns were analyzed. In cases when the attenuation changes were decreased, we presumed Warthin tumor preoperatively and performed extracapsular dissection. When the attenuation changes were increased, superficial parotidectomy was performed on the parotid gland tumors. We analyzed the operation times, incision sizes, complications, and recurrence rates. Results Attenuation of Warthin tumors was decreased from early to delayed scans. The ratio of CT numbers in Warthin tumors was also significantly different from other tumors. Warthin tumors were diagnosed with a sensitivity of 96.1% and specificity of 97% using two-phase CT. The mean operation time was 38 minutes and the mean incision size was 36.2 mm for Warthin tumors. However, for the other parotid tumors, the average operation time was 122 minutes and the average incision size was 91.8 mm (P<0.05). Conclusion Salivary Warthin tumor has a distinct pattern of contrast enhancement on two-phase CT, which can guide treatment decisions. The preoperative diagnosis of Warthin tumor made extracapsular dissection possible instead of superficial parotidectomy. PMID:25177439

  3. TRENCADIS--a WSRF grid MiddleWare for managing DICOM structured reporting objects.

    PubMed

    Blanquer, Ignacio; Hernandez, Vicente; Segrelles, Damià

    2006-01-01

    The adoption of the digital processing of medical data, especially on radiology, has leaded to the availability of millions of records (images and reports). However, this information is mainly used at patient level, being the extraction of information, organised according to administrative criteria, which make the extraction of knowledge difficult. Moreover, legal constraints make the direct integration of information systems complex or even impossible. On the other side, the widespread of the DICOM format has leaded to the inclusion of other information different from just radiological images. The possibility of coding radiology reports in a structured form, adding semantic information about the data contained in the DICOM objects, eases the process of structuring images according to content. DICOM Structured Reporting (DICOM-SR) is a specification of tags and sections to code and integrate radiology reports, with seamless references to findings and regions of interests of the associated images, movies, waveforms, signals, etc. The work presented in this paper aims at developing of a framework to efficiently and securely share medical images and radiology reports, as well as to provide high throughput processing services. This system is based on a previously developed architecture in the framework of the TRENCADIS project, and uses other components such as the security system and the Grid processing service developed in previous activities. The work presented here introduces a semantic structuring and an ontology framework, to organise medical images considering standard terminology and disease coding formats (SNOMED, ICD9, LOINC..).

  4. Clinical and radiological mid-term results of the thrust plate prosthesis

    PubMed Central

    v.d. Daele, R.; Simon, U.; Goetze, C.

    2009-01-01

    The purpose of this study was to perform an objective clinical and radiological assessment of the thrust plate prosthesis (TPP). Fifty-three prostheses were evaluated clinically using the Harris hip score (HHS), visual analog scale (VAS), and radiographically before surgery, at the time of discharge, and postoperatively after on average of 8.09 (range 4.61–9.93) years. The average HHS significantly (p ≤ 0.05) improved from 48 (range 18–77) points to 95 (range 46–100) points. The VAS revealed significant (p ≤ 0.05) reduction of pain at rest and under load. Radiographic analysis showed a considerable potential for osteolysis under the thrust plate. Sixteen prostheses revealed signs of radiolucent zones. In general, there was a good clinical outcome with no major limitations in function. Radiographic changes under the thrust plate indicate an adaptation processes resulting from changed biomechanics. This study suggests that the TPP could be a good alternative in total hip replacement in younger patients. PMID:19184010

  5. Investigation of injury/illness data at a nuclear facility. Part II

    DOE PAGES

    Cournoyer, Michael E.; Garcia, Vincent E.; Sandoval, Arnold N.; ...

    2015-07-01

    At Los Alamos National Laboratory (LANL), there are several nuclear facilities, accelerator facilities, radiological facilities, explosives sites, moderate- and high-hazard non-nuclear facilities, biosciences laboratory, etc. The Plutonium Science and Manufacturing Directorate (ADPSM) provides special nuclear material research, process development, technology demonstration, and manufacturing capabilities. ADPSM manages the LANL Plutonium Facility. Within the Radiological Control Area at TA-55 (PF-4), chemical and metallurgical operations with plutonium and other hazardous materials are performed. LANL Health and Safety Programs investigate injury and illness data. In this study, statistically significant trends have been identified and compared for LANL, ADPSM, and PF-4 injury/illness cases. A previouslymore » described output metric is used to measures LANL management progress towards meeting its operational safety objectives and goals. Timelines are used to determine trends in Injury/Illness types. Pareto Charts are used to prioritize causal factors. The data generated from analysis of Injury/Illness data have helped identify and reduce the number of corresponding causal factors.« less

  6. The American Board of Radiology Perspective on Maintenance of Certification: Part IV: Practice quality improvement in radiologic physics.

    PubMed

    Frey, G Donald; Ibbott, Geoffrey S; Morin, Richard L; Paliwal, Bhudatt R; Thomas, Stephen R; Bosma, Jennifer

    2007-11-01

    Recent initiatives of the American Board of Medical Specialties (ABMS) in the area of maintenance of certification (MOC) have been reflective of the response of the medical community to address public concerns regarding quality of care, medical error reduction, and patient safety. In March 2000, the 24 member boards of the ABMS representing all medical subspecialties in the USA agreed to initiate specialty-specific maintenance of certification (MOC) programs. The American Board of Radiology (ABR) MOC program for diagnostic radiology, radiation oncology, and radiologic physics has been developed, approved by the ABMS, and initiated with full implementation for all three disciplines beginning in 2007. The overriding objective of MOC is to improve the quality of health care through diplomate-initiated learning and quality improvement. The four component parts to the MOC process are: Part I: Professional standing, Part II: Evidence of life long learning and periodic self-assessment, Part III: Cognitive expertise, and Part IV: Evaluation of performance in practice (with the latter being the focus of this paper). The key components of Part IV require a physicist-based response to demonstrate commitment to practice quality improvement (PQI) and progress in continuing individual competence in practice. Diplomates of radiologic physics must select a project to be completed over the ten-year cycle that potentially can improve the quality of the diplomate's individual or systems practice and enhance the quality of care. Five categories have been created from which an individual radiologic physics diplomate can select one required PQI project: (1) Safety for patients, employees, and the public, (2) accuracy of analyses and calculations, (3) report turnaround time and communication issues, (4) practice guidelines and technical standards, and (5) surveys (including peer review of self-assessment reports). Each diplomate may select a project appropriate for an individual, participate in a project within a clinical department, participate in a peer review of a self-assessment report, or choose a qualified national project sponsored by a society. Once a project has been selected, the steps are: (1) Collect baseline data relevant to the chosen project, (2) review and analyze the data, (3) create and implement an improvement plan, (4) remeasure and track, and (5) report participation to the ABR, using the template provided by the ABR. These steps begin in Year 2, following training in Year 1. Specific examples of individual PQI projects for each of the three disciplines of radiologic physics are provided. Now, through the MOC programs, the relationship between the radiologic physicist and the ABR will be continuous through the diplomate's professional career. The ABR is committed to providing an effective infrastructure that will promote and assist the process of continuing professional development including the enhancement of practice quality improvement for radiologic physicists.

  7. Machine Learning in Radiology: Applications Beyond Image Interpretation.

    PubMed

    Lakhani, Paras; Prater, Adam B; Hutson, R Kent; Andriole, Kathy P; Dreyer, Keith J; Morey, Jose; Prevedello, Luciano M; Clark, Toshi J; Geis, J Raymond; Itri, Jason N; Hawkins, C Matthew

    2018-02-01

    Much attention has been given to machine learning and its perceived impact in radiology, particularly in light of recent success with image classification in international competitions. However, machine learning is likely to impact radiology outside of image interpretation long before a fully functional "machine radiologist" is implemented in practice. Here, we describe an overview of machine learning, its application to radiology and other domains, and many cases of use that do not involve image interpretation. We hope that better understanding of these potential applications will help radiology practices prepare for the future and realize performance improvement and efficiency gains. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  8. Defining quality in radiology.

    PubMed

    Blackmore, C Craig

    2007-04-01

    The introduction of pay for performance in medicine represents an opportunity for radiologists to define quality in radiology. Radiology quality can be defined on the basis of the production model that currently drives reimbursement, codifying the role of radiologists as being limited to the production of timely and accurate radiology reports produced in conditions of maximum patient safety and communicated in a timely manner. Alternately, quality in radiology can also encompass the professional role of radiologists as diagnostic imaging specialists responsible for the appropriate use, selection, interpretation, and application of imaging. Although potentially challenging to implement, the professional model for radiology quality is a comprehensive assessment of the ways in which radiologists add value to patient care. This essay is a discussion of the definition of radiology quality and the implications of that definition.

  9. Do Residency Selection Factors Predict Radiology Resident Performance?

    PubMed

    Agarwal, Vikas; Bump, Gregory M; Heller, Matthew T; Chen, Ling-Wan; Branstetter, Barton F; Amesur, Nikhil B; Hughes, Marion A

    2018-03-01

    The purpose of our study is to determine what information in medical student residency applications predicts radiology residency success as defined by objective clinical performance data. We performed a retrospective cohort study of residents who entered our institution's residency program through the National Resident Matching Program as postgraduate year 2 residents and completed the program over the past 2 years. Medical school grades, selection to Alpha Omega Alpha (AOA) Honor Society, United States Medical Licensing Examination (USMLE) scores, publication in peer-reviewed journals, and whether the applicant was from a peer institution were the variables examined. Clinical performance was determined by calculating each resident's cumulative major discordance rate for on-call cases the resident read and gave a preliminary interpretation. A major discordance was defined as a difference between the preliminary resident and the final attending interpretations that could immediately impact the care of the patient. A multivariate logistic regression was performed to determine significant variables. Twenty-seven residents provided preliminary reports on call for 67,145 studies. The mean major discordance rate was 1.08% (range 0.34%-2.54%). Higher USMLE Step 1 scores, publication before residency, and election to AOA Honor Society were all statistically significant predictors of lower major discordance rates (P values 0.01, 0.01,  and <0.001, respectively). Overall resident performance was excellent. There are predictors that help select the better performing residents, namely higher USMLE Step 1 scores, one to two publications during medical school, and election to AOA in the junior year of medical school. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  10. Exploring the Usability of Mobile Apps Supporting Radiologists' Training in Diagnostic Decision Making.

    PubMed

    Kim, Min Soon; Aro, Michael R; Lage, Kraig J; Ingalls, Kevin L; Sindhwani, Vivek; Markey, Mia K

    2016-03-01

    The objective of this study was to conduct a usability evaluation of mobile apps for supporting education and training in radiologic diagnostic decision-making processes. Of 381 mobile apps available at two major stores (Google Play and iTunes), eight iOS apps were selected for laboratory-based usability tests. Six staff radiologists completed eight app-specific task sets, using a think-aloud strategy. The triangular methods approach included quantitative performance measures, System Usability Scale (SUS), and qualitative thematic analysis using heuristic usability principles of usability issues. Overall, radiologists achieved higher than 70% success, with favorable SUS scores, in completing the tasks for seven of the eight apps. However, task success rate and SUS score had a weak relation (r = 0.23), indicating that the perceived usability may not reflect the holistic usability of the app. Task analysis and self-report revealed 108 usability issues, which were condensed to 55 unique issues and categorized by nine usability themes and mapped to ten usability heuristics. Nonintuitive functionality (eg, nonintuitive or misleading labels) was the most frequent theme observed, leading to inefficient navigation. These usability findings were consistent with the 13 improvements the radiologists suggested. This study demonstrates the feasibility of usability evaluation of radiology mobile apps and suggests potential improvements in the development of radiology mobile apps. This study also suggests that proficiency with mobile devices may not be equivalent to being an expert user, proficient in using the apps. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. Ambient lighting: setting international standards for the viewing of softcopy chest images

    NASA Astrophysics Data System (ADS)

    McEntee, Mark F.; Ryan, John; Evanoff, Micheal G.; Keeling, Aoife; Chakraborty, Dev; Manning, David; Brennan, Patrick C.

    2007-03-01

    Clinical radiological judgments are increasingly being made on softcopy LCD monitors. These monitors are found throughout the hospital environment in radiological reading rooms, outpatient clinics and wards. This means that ambient lighting where clinical judgments from images are made can vary widely. Inappropriate ambient lighting has several deleterious effects: monitor reflections reduce contrast; veiling glare adds brightness; dynamic range and detectability of low contrast objects is limited. Radiological images displayed on LCDs are more sensitive to the impact of inappropriate ambient lighting and with these devices problems described above are often more evident. The current work aims to provide data on optimum ambient lighting, based on lesions within chest images. The data provided may be used for the establishment of workable ambient lighting standards. Ambient lighting at 30cms from the monitor was set at 480 Lux (office lighting) 100 Lux (WHO recommendations), 40 Lux and <10 Lux. All monitors were calibrated to DICOM part 14 GSDF. Sixty radiologists were presented with 30 chest images, 15 images having simulated nodular lesions of varying subtlety and size. Lesions were positioned in accordance with typical clinical presentation and were validated radiologically. Each image was presented for 30 seconds and viewers were asked to identify and score any visualized lesion from 1-4 to indicate confidence level of detection. At the end of the session, sensitivity and specificity were calculated. Analysis of the data suggests that visualization of chest lesions is affected by inappropriate lighting with chest radiologists demonstrating greater ambient lighting dependency. JAFROC analyses are currently being performed.

  12. The value of medical student radiology education: A comparison of 1-week, 2-week, electives, and compulsories.

    PubMed

    Limchareon, Sornsupha; Kongprompsuk, Sutasinee

    2018-06-01

    Basic radiology interpretive skill is essential for all physicians. We developed a vertical type of radiology education, including basic radiology in the students' first clinical year and added the other 1-week or 2-week dedicated radiology rotation in the later clinical year. The objective of this study was to present a valuable radiology education to undergraduate medical students. At academic year 2014-2015, there were three different groups of the clinical-year students took a radiology rotation. All students completed the pretest of 30-image quiz at the first day of the course and the posttest of the same quiz at the last day of the course. The mean scores and the mean score changes of pretest and posttest were compared. A grade point average was used to determine the students' background characteristics. The relationships between students' background characteristics and the mean score changes were calculated. There were three groups of students including; 11 sixth-year elective students, 19 fifth-year compulsory students and 39 sixth-year compulsory students. The mean posttest score of all students were statistically significant greater than the mean pretest score (p < .001). For the students' years, time space or interest level had no significant effects on the improved score. Adding a 1-week dedicated radiology rotation to fifth- or sixth-year students after they finished the standard radiology course is beneficial to students. This type of vertical radiology curriculum is valuable and should be incorporated into formal medical school curricula. Copyright © 2017. Published by Elsevier Taiwan LLC.

  13. 2015 Groundwater Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Ponds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Michael George

    This report summarizes radiological monitoring results from groundwater wells associated with the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Ponds Reuse Permit (I-161-02). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

  14. Radiologically occult medulloblastoma with hydrocephalus: case report.

    PubMed

    Honma, Hirokuni; Ogiwara, Hideki

    2017-09-01

    There have been no reports of occult medulloblastoma nor noncommunicating hydrocephalus due to radiologically occult brain tumors. Herein, we report radiologically occult medulloblastoma with noncommunicating hydrocephalus. A 3-year-old boy presented with macrocephaly, visual field constriction, and papilledema. Neuroimagings showed enlargement of the ventricles without any mass lesions. The CT cisternography did not show influx of the contrast into the ventricles, which suggested local cerebrospinal fluid (CSF) circulatory disturbance at the outlet of the fourth ventricle. Due to possible obstructive nature of hydrocephalus, endoscopic third ventriculostomy (ETV) was performed. Three months after the ETV, he presented with repeated vomiting. Neuroimagings showed a 3-cm fourth ventricular mass with progressive hydrocephalus. Surgical resection was performed, which revealed the pathology was medulloblastoma. We report the case of radiologically occult medulloblastoma which was demonstrated radiologically in the follow-up period of ETV for noncommunicating hydrocephalus of uncertain etiology. This is the first description of a radiologically occult medulloblastoma and also the first description of an occult brain tumor with noncommunicating hydrocephalus. The occult brain tumor may be included in the etiology of hydrocephalus.

  15. Analysis of Operation TEAPOT nuclear test BEE radiological and meteorological data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quinn, V.E.

    This report describes the Weather Service Nuclear Support Office (WSNSO) analyses of the radiological and meteorological data collected for the BEE nuclear test of Operation TEAPOT. Inconsistencies in the radiological data and their resolution are discussed. The methods of normalizing the radiological data to a standard time and estimating fallout-arrival times are presented. The meteorological situations on event day and the following day are described. A comparison of the WSNSO fallout analysis with an analysis performed in the 1950's is presented. The radiological data used to derive the WSNSO fallout pattern are tabulated in an appendix.

  16. The development of a learning management system for dental radiology education: A technical report.

    PubMed

    Chang, Hee-Jin; Symkhampha, Khanthaly; Huh, Kyung-Hoe; Yi, Won-Jin; Heo, Min-Suk; Lee, Sam-Sun; Choi, Soon-Chul

    2017-03-01

    This study was conducted to suggest the development of a learning management system for dental radiology education using the Modular Object-Oriented Dynamic Learning Environment (Moodle). Moodle is a well-known and verified open-source software-learning management system (OSS-LMS). The Moodle software was installed on a server computer and customized for dental radiology education. The system was implemented for teaching undergraduate students to diagnose dental caries in panoramic images. Questions were chosen that could assess students' diagnosis ability. Students were given several questions corre-sponding to each of 100 panoramic images. The installation and customization of Moodle was feasible, cost-effective, and time-saving. By having students answer questions repeatedly, it was possible to train them to examine panoramic images sequentially and thoroughly. Based on its educational efficiency and efficacy, the adaptation of an OSS-LMS in dental school may be highly recommended. The system could be extended to continuing education for dentists. Further studies on the objective evaluation of knowledge acquisition and retention are needed.

  17. General practitioners’ views on radiology reports of plain radiography for back pain

    PubMed Central

    Espeland, Ansgar; Baerheim, Anders

    2007-01-01

    Objective To identify and describe general practitioners’ (GPs’) views on radiology reports, using plain radiography for back pain as the case. Design Qualitative study with three focus-group interviews analysed using Giorgi's method as modified by Malterud. Setting Southern Norway. Subjects Five female and eight male GPs aged 32–57 years who had practised for 3–15 years and were from 11 different practices. Main outcome measures Descriptions of GPs’ views. Results GPs wanted radiology reports to indicate more clearly the meaning of radiological terminology, the likelihood of disease, the clinical relevance of the findings, and/or the need for further investigations. GPs stated that good referral information leads to better reports. Conclusion These results can help to improve communication between radiologists and GPs. The issues identified in this study could be further investigated in studies that can quantify GPs’ satisfaction with radiology reports in relation to characteristics of the GP, the radiologist, and the referral information. PMID:17354154

  18. The advantages, disadvantages, and policies for part-time radiologists: report of the ACR Commission on Human Resources.

    PubMed

    Harolds, Jay A; Coleman, Beverly G; Recht, Michael P; Bluth, Edward I

    2014-07-01

    The employment of part-time radiologists (PTRs) has both advantages and disadvantages in various practice settings. The authors examine the pros and cons of PTRs and review the literature regarding PTRs both within and outside the specialty of radiology. The complexity of this issue is manifested in our inability to reach consensus on many policy issues for PTRs. Nevertheless, this article should be helpful in offering an objective, nonbiased background to initiating a discussion on employing PTRs in various radiology practices. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  19. Computer-assisted virtual autopsy using surgical navigation techniques.

    PubMed

    Ebert, Lars Christian; Ruder, Thomas D; Martinez, Rosa Maria; Flach, Patricia M; Schweitzer, Wolf; Thali, Michael J; Ampanozi, Garyfalia

    2015-01-01

    OBJECTIVE; Virtual autopsy methods, such as postmortem CT and MRI, are increasingly being used in forensic medicine. Forensic investigators with little to no training in diagnostic radiology and medical laypeople such as state's attorneys often find it difficult to understand the anatomic orientation of axial postmortem CT images. We present a computer-assisted system that permits postmortem CT datasets to be quickly and intuitively resliced in real time at the body to narrow the gap between radiologic imaging and autopsy. Our system is a potentially valuable tool for planning autopsies, showing findings to medical laypeople, and teaching CT anatomy, thus further closing the gap between radiology and forensic pathology.

  20. Machine Learning and Radiology

    PubMed Central

    Wang, Shijun; Summers, Ronald M.

    2012-01-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. PMID:22465077

  1. A dramatic, objective antiandrogen withdrawal response: case report and review of the literature.

    PubMed

    Lau, Yiu-Keung; Chadha, Manpreet K; Litwin, Alan; Trump, Donald L

    2008-11-05

    Antiandrogen withdrawal response is an increasingly recognized entity in patients with metastatic prostate cancer. To our knowledge, there have been no reports describing a durable radiologic improvement along with prostate-specific antigen (PSA) with discontinuation of the antiandrogen agent bicalutamide. We report a case in which a dramatic decline of serum PSA levels associated with a dramatic improvement in radiologic disease was achieved with bicalutamide discontinuation.

  2. Quantitative Stratification of Diffuse Parenchymal Lung Diseases

    PubMed Central

    Raghunath, Sushravya; Rajagopalan, Srinivasan; Karwoski, Ronald A.; Maldonado, Fabien; Peikert, Tobias; Moua, Teng; Ryu, Jay H.; Bartholmai, Brian J.; Robb, Richard A.

    2014-01-01

    Diffuse parenchymal lung diseases (DPLDs) are characterized by widespread pathological changes within the pulmonary tissue that impair the elasticity and gas exchange properties of the lungs. Clinical-radiological diagnosis of these diseases remains challenging and their clinical course is characterized by variable disease progression. These challenges have hindered the introduction of robust objective biomarkers for patient-specific prediction based on specific phenotypes in clinical practice for patients with DPLD. Therefore, strategies facilitating individualized clinical management, staging and identification of specific phenotypes linked to clinical disease outcomes or therapeutic responses are urgently needed. A classification schema consistently reflecting the radiological, clinical (lung function and clinical outcomes) and pathological features of a disease represents a critical need in modern pulmonary medicine. Herein, we report a quantitative stratification paradigm to identify subsets of DPLD patients with characteristic radiologic patterns in an unsupervised manner and demonstrate significant correlation of these self-organized disease groups with clinically accepted surrogate endpoints. The proposed consistent and reproducible technique could potentially transform diagnostic staging, clinical management and prognostication of DPLD patients as well as facilitate patient selection for clinical trials beyond the ability of current radiological tools. In addition, the sequential quantitative stratification of the type and extent of parenchymal process may allow standardized and objective monitoring of disease, early assessment of treatment response and mortality prediction for DPLD patients. PMID:24676019

  3. Subspecialisation in Emergency Radiology: Proposal for a harmonised European curriculum.

    PubMed

    Wagner, M G; Fischer, M R; Scaglione, M; Linsenmaier, U; Schueller, G; Berger, F H; Dick, E; Basilico, R; Stajgis, M; Calli, C; Vaidya, S; Wirth, Stefan

    2017-01-01

    Introduction: Radiology plays a crucial role in the emergency care setting by delivering early and precise diagnoses under pressure of time, right at the beginning of patient treatment. Although there is a need for postgraduate education in emergency radiology, most of the national bodies responsible do not offer it in a uniform fashion and a general proof of qualification is missing in Europe. Therefore, the European Society of Radiology (ESR) has founded the (Sub-)Society of Emergency Radiology (ESER), prompting them to develop a European curriculum. This trend, which is currently also encouraged in many other non-radiological specialties which demand the highest professional qualifications, often lacks expertise in medical education. Goals: The goal of this article is the general description of the curricular planning process for a European postgraduate subspecialisation programme, using the example of Emergency Radiology (European Diploma in Emergency Radiology, EDER), including the utilisation of TOOLS and recommendations derived from comparable projects. Project description: The project was divided into partial steps: the timeline displayed in a GANTT chart, and tasks and responsibilities assigned in a RASCI matrix. The curriculum was iteratively developed using the KERN approach and steps were prioritised using the PARETO principle. Furthermore, the following TOOLS were used: limitations and needs assessment, SWOT analysis, formulating learning objectives and categorising them after MILLER and SCLO, and using BLOOM's taxonomy for cognitive learning objectives and operationalising them according to MAGER. Psychomotoric and affective learning objectives were assigned to CANMEDS roles, grouped by topic using CLUSTERING, and then mapped by MATRIX analysis to appropriate learning and evaluation methods. Striving for continuous improvement, the curriculum was finally embedded in curricular quality management. Results: The standardisation of the EDER access, considering the different national conditions, the minimisation of European learners' attendance phases, restricting expenses by best possible use of existing structures, respecting the requirements and retaining the support of the European umbrella society ESR, finishing the project by a specific deadline and the demands of continuous improvement were particular challenges. A curriculum with the eligibility of five years' speciality training in general radiology has evolved on schedule. The subspeciality training lasts at least one year and is divided into webinars, workshops during congresses (e.g. the annual ESR and ESER congresses) and one year practical training at the individual learner's corresponding local hospitals, which adhere to a catalogue of requirements, comparable to national educational policies. The curriculum is completed by passing a written and oral exam (diploma) and re-accreditation every five years. Conclusions: Despite complex requirements, the TOOLS utilised allowed an almost seamless, resource-minimised, professional, location-independent distributed development of a European subspeciality curriculum within one year. The definitive implementation is still due. If any deviations from the draft presented should become necessary in the future, the embedment in the curricular quality management will lead to a redirection in the right way and, furthermore, secure a continuous improvement in the best way possible.

  4. Subspecialisation in Emergency Radiology: Proposal for a harmonised European curriculum

    PubMed Central

    Wagner, M. G.; Fischer, M. R.; Scaglione, M.; Linsenmaier, U.; Schueller, G.; Berger, F. H.; Dick, E.; Basilico, R.; Stajgis, M.; Calli, C.; Vaidya, S.; Wirth, Stefan

    2017-01-01

    Introduction: Radiology plays a crucial role in the emergency care setting by delivering early and precise diagnoses under pressure of time, right at the beginning of patient treatment. Although there is a need for postgraduate education in emergency radiology, most of the national bodies responsible do not offer it in a uniform fashion and a general proof of qualification is missing in Europe. Therefore, the European Society of Radiology (ESR) has founded the (Sub-)Society of Emergency Radiology (ESER), prompting them to develop a European curriculum. This trend, which is currently also encouraged in many other non-radiological specialties which demand the highest professional qualifications, often lacks expertise in medical education. Goals: The goal of this article is the general description of the curricular planning process for a European postgraduate subspecialisation programme, using the example of Emergency Radiology (European Diploma in Emergency Radiology, EDER), including the utilisation of TOOLS and recommendations derived from comparable projects. Project description: The project was divided into partial steps: the timeline displayed in a GANTT chart, and tasks and responsibilities assigned in a RASCI matrix. The curriculum was iteratively developed using the KERN approach and steps were prioritised using the PARETO principle. Furthermore, the following TOOLS were used: limitations and needs assessment, SWOT analysis, formulating learning objectives and categorising them after MILLER and SCLO, and using BLOOM’s taxonomy for cognitive learning objectives and operationalising them according to MAGER. Psychomotoric and affective learning objectives were assigned to CANMEDS roles, grouped by topic using CLUSTERING, and then mapped by MATRIX analysis to appropriate learning and evaluation methods. Striving for continuous improvement, the curriculum was finally embedded in curricular quality management. Results: The standardisation of the EDER access, considering the different national conditions, the minimisation of European learners’ attendance phases, restricting expenses by best possible use of existing structures, respecting the requirements and retaining the support of the European umbrella society ESR, finishing the project by a specific deadline and the demands of continuous improvement were particular challenges. A curriculum with the eligibility of five years’ speciality training in general radiology has evolved on schedule. The subspeciality training lasts at least one year and is divided into webinars, workshops during congresses (e.g. the annual ESR and ESER congresses) and one year practical training at the individual learner’s corresponding local hospitals, which adhere to a catalogue of requirements, comparable to national educational policies. The curriculum is completed by passing a written and oral exam (diploma) and re-accreditation every five years. Conclusions: Despite complex requirements, the TOOLS utilised allowed an almost seamless, resource-minimised, professional, location-independent distributed development of a European subspeciality curriculum within one year. The definitive implementation is still due. If any deviations from the draft presented should become necessary in the future, the embedment in the curricular quality management will lead to a redirection in the right way and, furthermore, secure a continuous improvement in the best way possible. PMID:29226229

  5. Is there an association between clinical features, response to diagnostic analgesia and radiological findings in horses with a magnetic resonance imaging diagnosis of navicular disease or other injuries of the podotrochlear apparatus?

    PubMed

    Parkes, Rebecca; Newton, Richard; Dyson, Sue

    2015-04-01

    Previous descriptions of the clinical features of navicular disease occurred before the widespread use of magnetic resonance imaging (MRI) allowed a more definitive diagnosis of foot pain. The objective of this study was to compare the clinical features of horses with lesions of the podotrochlear apparatus with those with other causes of foot pain. It was hypothesised that primary navicular bone disease would be associated with more advanced radiological findings than other diagnoses. A retrospective study was performed of all horses examined at a referral centre with a definitive diagnosis of foot pain based on MRI ± post-mortem examination. Clinical examination findings, response to diagnostic analgesia and radiological grading of the navicular bone were compared among five diagnosis groups: (1) primary navicular bone pathology (NB); (2) lesions of the collateral sesamoidean ligament and/or distal sesamoidean impar ligament (CSL + DSIL); (3) primary deep digital flexor tendon injury (DDFT); (4) navicular bone pathology and other lesions of the podotrochlear apparatus ± DDFT (PTA) and (5) Other. There were 702 horses (NB, 62; CSL + DSIL, 180; DDFT, 69; PTA, 92; Other, 299). Horses with PTA injuries were more frequently unilaterally lame than other groups (P = 0.04). Horses with DDFT injury were more likely to exhibit pain on turning than other groups (P <0.01). There were no associations between response to diagnostic analgesia and diagnostic group, and no association between radiological grade and diagnostic group. Clinical examination findings generally did not discriminate between diseases of the PTA and other causes of foot pain. Overall radiological scores of the navicular bone did not accurately predict navicular bone pathology. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Questionnaire surveys of dentists on radiology

    PubMed Central

    Shelley, AM; Brunton, P; Horner, K

    2012-01-01

    Objectives Survey by questionnaire is a widely used research method in dental radiology. A major concern in reviews of questionnaires is non-response. The objectives of this study were to review questionnaire studies in dental radiology with regard to potential survey errors and to develop recommendations to assist future researchers. Methods A literature search with the software search package PubMed was used to obtain internet-based access to Medline through the website www.ncbi.nlm.nih.gov/pubmed. A search of the English language peer-reviewed literature was conducted of all published studies, with no restriction on date. The search strategy found articles with dates from 1983 to 2010. The medical subject heading terms used were “questionnaire”, “dental radiology” and “dental radiography”. The reference sections of articles retrieved by this method were hand-searched in order to identify further relevant papers. Reviews, commentaries and relevant studies from the wider literature were also included. Results 53 questionnaire studies were identified in the dental literature that concerned dental radiography and included a report of response rate. These were all published between 1983 and 2010. In total, 87 articles are referred to in this review, including the 53 dental radiology studies. Other cited articles include reviews, commentaries and examples of studies outside dental radiology where they are germane to the arguments presented. Conclusions Non-response is only one of four broad areas of error to which questionnaire surveys are subject. This review considers coverage, sampling and measurement, as well as non-response. Recommendations are made to assist future research that uses questionnaire surveys. PMID:22517994

  7. A dramatic, objective antiandrogen withdrawal response: case report and review of the literature

    PubMed Central

    Lau, Yiu-Keung; Chadha, Manpreet K; Litwin, Alan; Trump, Donald L

    2008-01-01

    Antiandrogen withdrawal response is an increasingly recognized entity in patients with metastatic prostate cancer. To our knowledge, there have been no reports describing a durable radiologic improvement along with prostate-specific antigen (PSA) with discontinuation of the antiandrogen agent bicalutamide. We report a case in which a dramatic decline of serum PSA levels associated with a dramatic improvement in radiologic disease was achieved with bicalutamide discontinuation. PMID:18986533

  8. Radiology operations: what you don't know could be costing you millions.

    PubMed

    Joffe, Sam; Drew, Donna; Bansal, Manju; Hase, Michael

    2007-01-01

    Rapid growth in advanced imaging procedures has left hospital radiology departments struggling to keep up with demand, resulting in loss of patients to facilities that can offer service more quickly. While the departments appear to be working at full capacity, an operational analysis of over 400 hospital radiology departments in the US by GE Healthcare has determined that, paradoxically, many departments are in fact underutilized and operating for below their potential capacity. While CT cycle time in hospitals that were studied averaged 35 minutes, top performing hospitals operated the same equipment at a cycle time of 15 minutes, yielding approximately double the throughput volume. Factors leading to suboptimal performance include accounting metrics that mask true performance, leadership focus on capital investment rather than operations, under staffing, under scheduling, poorly aligned incentives, a fragmented view of operations, lack of awareness of latent opportunities, and lack of sufficient skills and processes to implement improvements. The study showed how modest investments in radiology operations can dramatically improve access to services and profitability.

  9. Radiological Scoping Survey of the Scotia Depot Scotia, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    E. N. Bailey

    2005-02-05

    At the request of the Defense Logistics Agency, the Oak Ridge Institute for Science and Education conducted radiological scoping surveys of the Scotia Depot during the period of September 24 through 27, 2007. The scoping survey included visual inspections and limited radiological surveys performed in accordance with area classification that included surface scans, total and removable activity measurements, and soil sampling.

  10. Applications for a hybrid operating room in thoracic surgery: from multidisciplinary procedures to ­­image-guided video-assisted thoracoscopic surgery

    PubMed Central

    Terra, Ricardo Mingarini; Andrade, Juliano Ribeiro; Mariani, Alessandro Wasum; Garcia, Rodrigo Gobbo; Succi, Jose Ernesto; Soares, Andrey; Zimmer, Paulo Marcelo

    2016-01-01

    ABSTRACT The concept of a hybrid operating room represents the union of a high-complexity surgical apparatus with state-of-the-art radiological tools (ultrasound, CT, fluoroscopy, or magnetic resonance imaging), in order to perform highly effective, minimally invasive procedures. Although the use of a hybrid operating room is well established in specialties such as neurosurgery and cardiovascular surgery, it has rarely been explored in thoracic surgery. Our objective was to discuss the possible applications of this technology in thoracic surgery, through the reporting of three cases. PMID:27812640

  11. ICRP Publication 138: Ethical Foundations of the System of Radiological Protection.

    PubMed

    Cho, K-W; Cantone, M-C; Kurihara-Saio, C; Le Guen, B; Martinez, N; Oughton, D; Schneider, T; Toohey, R; ZöLzer, F

    2018-02-01

    Despite a longstanding recognition that radiological protection is not only a matter of science, but also ethics, ICRP publications have rarely addressed the ethical foundations of the system of radiological protection explicitly. The purpose of this publication is to describe how the Commission has relied on ethical values, either intentionally or indirectly, in developing the system of radiological protection with the objective of presenting a coherent view of how ethics is part of this system. In so doing, it helps to clarify the inherent value judgements made in achieving the aim of the radiological protection system as underlined by the Commission in Publication 103. Although primarily addressed to the radiological protection community, this publication is also intended to address authorities, operators, workers, medical professionals, patients, the public, and its representatives (e.g. NGOs) acting in the interest of the protection of people and the environment. This publication provides the key steps concerning the scientific, ethical, and practical evolutions of the system of radiological protection since the first ICRP publication in 1928. It then describes the four core ethical values underpinning the present system: beneficence/ non-maleficence, prudence, justice, and dignity. It also discusses how these core ethical values relate to the principles of radiological protection, namely justification, optimisation, and limitation. The publication finally addresses key procedural values that are required for the practical implementation of the system, focusing on accountability, transparency, and inclusiveness. The Commission sees this publication as a founding document to be elaborated further in different situations and circumstances.

  12. Solutions in radiology services management: a literature review*

    PubMed Central

    Pereira, Aline Garcia; Vergara, Lizandra Garcia Lupi; Merino, Eugenio Andrés Díaz; Wagner, Adriano

    2015-01-01

    Objective The present study was aimed at reviewing the literature to identify solutions for problems observed in radiology services. Materials and Methods Basic, qualitative, exploratory literature review at Scopus and SciELO databases, utilizing the Mendeley and Illustrator CC Adobe softwares. Results In the databases, 565 papers – 120 out of them, pdf free – were identified. Problems observed in the radiology sector are related to procedures scheduling, humanization, lack of training, poor knowledge and use of management techniques, and interaction with users. The design management provides the services with interesting solutions such as Benchmarking, CRM, Lean Approach, ServiceBlueprinting, continued education, among others. Conclusion Literature review is an important tool to identify problems and respective solutions. However, considering the small number of studies approaching management of radiology services, this is a great field of research for the development of deeper studies. PMID:26543281

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demmer, Rick; Fox, Don; Reese, Stephen

    The Idaho National Laboratory (INL) and the United Kingdom (UK) National Nuclear Laboratory (NNL) have been collaborating for several years on materials and methods for the fogged/misted introduction of fixatives into radiologically contaminated facilities. The objective of the project is to deliver a process for reducing airborne radiological and/or mercury contamination and affixing loose contamination in place, thereby reducing contamination risk to employees and decreasing D&D cost and schedule. The developed process provides a reliable, unmanned method of introducing a coating that captures and fixes contamination in place within facilities. The INL coating, termed FX2, has undergone extensive non-radiological testing,more » including determination that it is non-flammable, affixes contamination and flows well through unusual geometries (testing at Florida International University). A series of non-active fogging trials for activity knock/tie-down application have been completed at NNL Workington on behalf of Idaho National Laboratory (INL). These trials performed by the NNL employed commercially available agricultural fogging equipment and the INL’s knock/tie-down latex formulation (FX-2). This testing successfully demonstrated the ability of the fogging devices to successfully spray the FX-2 formulation within various scenarios, and prepared the project for a radioactive trial. The INL has also developed a mercury vapor reducing form of the coating termed FX-Hg, which has shown great promise in laboratory studies.« less

  14. Classification of Radiological Changes in Burst Fractures

    PubMed Central

    Şentürk, Salim; Öğrenci, Ahmet; Gürçay, Ahmet Gürhan; Abdioğlu, Ahmet Atilla; Yaman, Onur; Özer, Ali Fahir

    2018-01-01

    AIM: Burst fractures can occur with different radiological images after high energy. We aimed to simplify radiological staging of burst fractures. METHODS: Eighty patients whom exposed spinal trauma and had burst fracture were evaluated concerning age, sex, fracture segment, neurological deficit, secondary organ injury and radiological changes that occurred. RESULTS: We performed a new classification in burst fractures at radiological images. CONCLUSIONS: According to this classification system, secondary organ injury and neurological deficit can be an indicator of energy exposure. If energy is high, the clinical status will be worse. Thus, we can get an idea about the likelihood of neurological deficit and secondary organ injuries. This classification has simplified the radiological staging of burst fractures and is a classification that gives a very accurate idea about the neurological condition. PMID:29531604

  15. Machine learning and radiology.

    PubMed

    Wang, Shijun; Summers, Ronald M

    2012-07-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. Copyright © 2012. Published by Elsevier B.V.

  16. Results of the independent verification of radiological remedial action at 397 East 3rd South Street, Monticello, Utah (MS00168)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, M.J.; Crutcher, J.W.

    1991-07-01

    In 1980 the site of a vanadium and uranium mill at Monticello, Utah, was accepted into the US Department of Energy's (DOE's) Surplus Facilities Management Program, with the objectives of restoring the government-owned mill site to safe levels of radioactivity, disposing of or containing the tailings in an environmentally safe manner, and performing remedial actions on off-site (vicinity) properties that had been contaminated by radioactive material resulting from mill operations. During 1987 and 1988, UNC Geotech, the remedial action contractor designated by DOE, performed remedial action on the vicinity property at 397 East 3rd South Street, Monticello, Utah. The Pollutantmore » Assessments Group (PAG) of Oak Ridge National Laboratory was assigned the responsibility of verifying the data supporting the adequacy of remedial action and confirming the site's compliance with DOE guidelines. The PAG found that the site successfully meets the DOE remedial action objectives. Procedures used by PAG are described. 3 refs., 2 tabs.« less

  17. Results of the independent verification of radiological remedial action at 464 South 1st East Street, Monticello, Utah (MS00071)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, M.J.; Crutcher, J.W.

    1991-07-01

    In 1980 the site of a vanadium and uranium mill at Monticello, Utah, was accepted into the US Department of Energy's (DOE's) Surplus Facilities Management Program, with the objectives of restoring the government-owned mill site to safe levels of radioactivity, disposing of or containing the tailings in an environmentally safe manner, and performing remedial actions on off-site (vicinity) properties that had been contaminated by radioactive material resulting from mill operations. During 1986 and 1987, UNC Geotech, the remedial action contractor designated by DOE, performed remedial action on the vicinity property at 464 South 1st East Street, Monticello, Utah. The Pollutantmore » Assessments Group (PAG) of Oak Ridge National Laboratory was assigned the responsibility of verifying the data supporting the adequacy of remedial action and confirming the site's compliance with DOE guidelines. The PAG found that the site successfully meets the DOE remedial action objectives. Procedures used by PAG are described. 3 refs., 2 tabs.« less

  18. Results of the independent verification of radiological remedial action at 87 East 500 South Street, Monticello, Utah (MS00153)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, M.J.; Crutcher, J.W.

    1991-07-01

    In 1980 the iste of a vanadium and uranium mill at Monticello, Utah, was accepted into the US Department of Energy's (DOE's) Surplus Facilities Management Program, with the objectives of restoring the government-owned mill site to safe levels of radioactivity, disposing of or containing the tailings in an environmentally safe manner, and performing remedial actions on off-site (vicinity) properties that had been contaminated by radioactive material resulting from mill operations. During 1987 and 1988, UNC Geotech, the remedial action contractor designated by DOE, performed remedial action on the vicinity property at 87 East 500 South Street, Monticello, Utah. The Pollutantmore » Assessments Group (PAG) of Oak Ridge National Laboratory was assigned the responsibility of verifying the data supporting the adequacy of remedial action and confirming the site's compliance with DOE guidelines. The PAG found that the site successfully meets the DOE remedial action objectives. Procedures used by PAG are described. 3 refs., 2 tabs.« less

  19. Results of the independent verification of radiological remedial action at 16 East 5th South Street, Monticello, Utah (MS00075)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, M.J.; Crutcher, J.W.

    1991-07-01

    In 1980 the site of a vanadium and uranium mill at Monticello, Utah, was accepted into the US Department of Energy's (DOE's) Surplus Facilities Management Program, with the objectives of restoring the government-owned mill site to safe levels of radioactivity, disposing of or containing the tailings in an environmentally safe manner, and performing remedial actions on off-site (vicinity) properties that had been contaminated by radioactive material resulting from mill operations. During 1984 UNC Geotech, the remedial action contractor designated by DOE, performed remedial action on the vicinity property at 16 East 5th South Street, Monticello, Utah. The Pollutant Assessments Groupmore » (PAG) of Oak Ridge National Laboratory was assigned the responsibility of verifying the data supporting the adequacy of remedial action and confirming the site's compliance with DOE guidelines. The PAG found that the site successfully meets the DOE remedial action objectives. Procedures used by PAG are described. 3 refs., 2 tabs.« less

  20. Selection and implementation of a distributed phased archive for a multivendor incremental approach to PACS

    NASA Astrophysics Data System (ADS)

    Smith, Edward M.; Wandtke, John; Robinson, Arvin E.

    1999-07-01

    The selection criteria for the archive were based on the objectives of the Medical Information, Communication and Archive System (MICAS), a multi-vendor incremental approach to PACS. These objectives include interoperability between all components, seamless integration of the Radiology Information System (RIS) with MICAS and eventually other hospital databases, all components must demonstrate DICOM compliance prior to acceptance and automated workflow that can be programmed to meet changes in the healthcare environment. The long-term multi-modality archive is being implemented in 3 or more phases with the first phase designed to provide a 12 to 18 month storage solution. This decision was made because the cost per GB of storage is rapidly decreasing and the speed at which data can be retrieved is increasing with time. The open-solution selected allows incorporation of leading edge, 'best of breed' hardware and software and provides maximum jukeboxes, provides maximum flexibility of workflow both within and outside of radiology. The selected solution is media independent, supports multiple jukeboxes, provides expandable storage capacity and will provide redundancy and fault tolerance at minimal cost. Some of the required attributes of the archive include scalable archive strategy, virtual image database with global query and object-oriented database. The selection process took approximately 10 months with Cemax-Icon being the vendor selected. Prior to signing a purchase order, Cemax-Icon performed a site survey, agreed upon the acceptance test protocol and provided a written guarantee of connectivity between their archive and the imaging modalities and other MICAS components.

  1. Application development environment for advanced digital workstations

    NASA Astrophysics Data System (ADS)

    Valentino, Daniel J.; Harreld, Michael R.; Liu, Brent J.; Brown, Matthew S.; Huang, Lu J.

    1998-06-01

    One remaining barrier to the clinical acceptance of electronic imaging and information systems is the difficulty in providing intuitive access to the information needed for a specific clinical task (such as reaching a diagnosis or tracking clinical progress). The purpose of this research was to create a development environment that enables the design and implementation of advanced digital imaging workstations. We used formal data and process modeling to identify the diagnostic and quantitative data that radiologists use and the tasks that they typically perform to make clinical decisions. We studied a diverse range of radiology applications, including diagnostic neuroradiology in an academic medical center, pediatric radiology in a children's hospital, screening mammography in a breast cancer center, and thoracic radiology consultation for an oncology clinic. We used object- oriented analysis to develop software toolkits that enable a programmer to rapidly implement applications that closely match clinical tasks. The toolkits support browsing patient information, integrating patient images and reports, manipulating images, and making quantitative measurements on images. Collectively, we refer to these toolkits as the UCLA Digital ViewBox toolkit (ViewBox/Tk). We used the ViewBox/Tk to rapidly prototype and develop a number of diverse medical imaging applications. Our task-based toolkit approach enabled rapid and iterative prototyping of workstations that matched clinical tasks. The toolkit functionality and performance provided a 'hands-on' feeling for manipulating images, and for accessing textual information and reports. The toolkits directly support a new concept for protocol based-reading of diagnostic studies. The design supports the implementation of network-based application services (e.g., prefetching, workflow management, and post-processing) that will facilitate the development of future clinical applications.

  2. Routine delayed voiding cystourethography after initial successful endoscopic treatment with Dextranomer/Hialuronic Acid Copolimer (Dx/HA) of vesicoureteral reflux (VUR). Is it necessary?

    PubMed

    García-Aparicio, L; Blázquez-Gómez, E; Vila Santandreu, A; Camacho Diaz, J A; Vila-Cots, J; Ramos Cebrian, M; de Haro, I; Martin, O; Tarrado, X

    2016-12-01

    Some guidelines recommend an early voiding cystourethrography (VCUG) after endoscopic treatment of vesicoureteral reflux (VUR), but there's no consensus if it's necessary a long-term follow-up in these patients. The aim of our study is analyze if it's necessary a delayed VCUG after initial successful treatment with Dx/HA. We have reviewed all medical charts of patients that underwent Dx/HA treatment from 2006 to 2010. We have selected patients with initial successful treatment and more than 3 years of radiological and clinical follow-up. We have analyzed late clinical and radiological outcomes. One hundred and sixty children with 228 refluxing ureters underwent Dx/HA endoscopic treatment with a mean follow-up of 52.13 months. Early VCUG was performed in 215 ureters with an initial successful rate of 84.1%. The group of study was 94/215 ureters with more than 3 years of follow-up with a delayed VCUG. VUR was still resolved in 79,8% of the ureters. Clinical success rate was 91.7%. The incidence of febrile urinary tract infection in those patients with cured VUR and those with a relapsed VUR was 8 and 15%, respectively; but there were no significant differences. We have not found any variable related with relapsed VUR except those ureters that initially received 2 injections (P<.05). If our objective in the treatment of VUR is to reduce the incidence of febrile urinary tract infection it is not necessary to perform a delayed VCUG even though the long-term radiological outcomes is worse than clinical outcome. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. [Controlling instruments in radiology].

    PubMed

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  4. Open Access Journal Policies: A Systematic Analysis of Radiology Journals.

    PubMed

    Narayan, Anand; Lobner, Katie; Fritz, Jan

    2018-02-01

    The open access movement has pushed for greater access to scientific knowledge by expanding access to scientific journal articles. There is limited information about the extent to which open access policies have been adopted by radiology journals. We performed a systematic analysis to ascertain the proportion of radiology journals with open access options. A search was performed with the assistance of a clinical informationist. Full and mixed English-language diagnostic and interventional radiology Web of Science journals (impact factors > 1.0) were included. Nuclear medicine, radiation oncology, physics, and solicitation-only journals were excluded. Primary outcome was open access option (yes or no) with additional outcomes including presence or absence of embargo, complete or partial copyright transfer, publication fees, and self-archiving policies. Secondary outcomes included journal citations, journal impact factors, immediacy, Eigenfactor, and article influence scores. Independent double readings were performed with differences resolved by consensus, supplemented by contacting editorial staff at each journal. In all, 125 journals were identified; review yielded 49 journals (39%, mean impact factor of 2.61). Thirty-six of the journals had open access options (73.4%), and four journals were exclusively open access (8.2%). Twelve-month embargoes were most commonly cited (90.6%) with 28.6% of journals stating that they did not require a complete transfer of copyright. Prices for open access options ranged from $750 to $4,000 (median $3,000). No statistically significant differences were found in journal impact measures comparing journals with open access options to journals without open access options. Diagnostic and interventional radiology journals have widely adopted open access options with a few radiology journals being exclusively open access. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  5. Pulmonary Toxocariasis: Initial and Follow-Up CT Findings in 63 Patients.

    PubMed

    Lee, Kyung Hee; Kim, Tae Jung; Lee, Kyung Won

    2015-06-01

    The objective of our study was to describe the characteristic radiologic findings of pulmonary toxocariasis on initial and follow-up chest CT. Between June 2010 and May 2014, 63 patients with serologically proven, clinically diagnosed pulmonary toxocariasis and chest CT examinations performed within 2 months of an enzyme-linked immunosorbent assay for toxocariasis were identified. Two chest radiologists retrospectively analyzed the chest CT examinations in consensus; they focused on the distribution, location, number, and internal characteristics of the pulmonary lesions. The pulmonary lesions tended to involve three or more lobes (49% [31/63]) on the initial CT; predominance of the abnormalities in a subpleural location (81% [51/63]) and in the lower lung zone (98% [62/63]) was noted. The number of pulmonary lesions per patient were from two to five (46% [29/63]), more than five (32% [20/63]), or one (22% [14/63]). The radiologic findings of pulmonary toxocariasis could be categorized into four different patterns: ground-glass opacities (GGOs), solid nodules, consolidations, and linear opacities. The most common pattern was ill-defined GGOs with or without solid portions (84% [53/63]). The solid nodule and patchy consolidation patterns were found in 29% (18/63) and 21% (13/63) of patients, respectively. In addition, linear opacities (1-2 mm thick and 8-25 mm long) were present in 19% of patients (12/63); this finding is a subtle, yet novel, finding. On follow-up CT, the pulmonary lesions had either disappeared or migrated; when they had migrated, they revealed radiologic manifestations similar to the findings on the initial CT. Pulmonary toxocariasis manifested as multiple lesions in four radiologic patterns with subpleural and lower lung predominance on initial and follow-up CT. A linear opacity may be one of many clues in the diagnosis of pulmonary toxocariasis on CT.

  6. A Comprehensive Analysis of Authorship in Radiology Journals.

    PubMed

    Dang, Wilfred; McInnes, Matthew D F; Kielar, Ania Z; Hong, Jiho

    2015-01-01

    The purpose of our study was to investigate authorship trends in radiology journals, and whether International Committee of Medical Journal Editors (ICMJE) recommendations have had an impact on these trends. A secondary objective was to explore other variables associated with authorship trends. A retrospective, bibliometric analysis of 49 clinical radiology journals published from 1946-2013 was conducted. The following data was exported from MEDLINE (1946 to May 2014) for each article: authors' full name, year of publication, primary author institution information, language of publication and publication type. Microsoft Excel Visual Basics for Applications scripts were programmed to categorize extracted data. Statistical analysis was performed to determine the overall mean number of authors per article over time, impact of ICMJE guidelines, authorship frequency per journal, country of origin, article type and language of publication. 216,271 articles from 1946-2013 were included. A univariate analysis of the mean authorship frequency per year of all articles yielded a linear relationship between time and authorship frequency. The mean number of authors per article in 1946 (1.42) was found to have increased consistently by 0.07 authors/ article per year (R² = 0.9728, P<0.001) to 5.79 authors/article in 2013. ICMJE guideline dissemination did not have an impact on this rise in authorship frequency. There was considerable variability in mean authors per article and change over time between journals, country of origin, language of publication and article type. Overall authorship for 49 radiology journals across 68 years has increased markedly with no demonstrated impact from ICMJE guidelines. A higher number of authors per article was seen in articles from: higher impact journals, European and Asian countries, original research type, and those journals who explicitly endorse the ICMJE guidelines.

  7. Does improved access to diagnostic imaging results reduce hospital length of stay? A retrospective study

    PubMed Central

    2010-01-01

    Background One year after the introduction of Information and Communication Technology (ICT) to support diagnostic imaging at our hospital, clinicians had faster and better access to radiology reports and images; direct access to Computed Tomography (CT) reports in the Electronic Medical Record (EMR) was particularly popular. The objective of this study was to determine whether improvements in radiology reporting and clinical access to diagnostic imaging information one year after the ICT introduction were associated with a reduction in the length of patients' hospital stays (LOS). Methods Data describing hospital stays and diagnostic imaging were collected retrospectively from the EMR during periods of equal duration before and one year after the introduction of ICT. The post-ICT period was chosen because of the documented improvement in clinical access to radiology results during that period. The data set was randomly split into an exploratory part used to establish the hypotheses, and a confirmatory part. The data was used to compare the pre-ICT and post-ICT status, but also to compare differences between groups. Results There was no general reduction in LOS one year after ICT introduction. However, there was a 25% reduction for one group - patients with CT scans. This group was heterogeneous, covering 445 different primary discharge diagnoses. Analyses of subgroups were performed to reduce the impact of this divergence. Conclusion Our results did not indicate that improved access to radiology results reduced the patients' LOS. There was, however, a significant reduction in LOS for patients undergoing CT scans. Given the clinicians' interest in CT reports and the results of the subgroup analyses, it is likely that improved access to CT reports contributed to this reduction. PMID:20819224

  8. A presentation system for just-in-time learning in radiology.

    PubMed

    Kahn, Charles E; Santos, Amadeu; Thao, Cheng; Rock, Jayson J; Nagy, Paul G; Ehlers, Kevin C

    2007-03-01

    There is growing interest in bringing medical educational materials to the point of care. We sought to develop a system for just-in-time learning in radiology. A database of 34 learning modules was derived from previously published journal articles. Learning objectives were specified for each module, and multiple-choice test items were created. A web-based system-called TEMPO-was developed to allow radiologists to select and view the learning modules. Web services were used to exchange clinical context information between TEMPO and the simulated radiology work station. Preliminary evaluation was conducted using the System Usability Scale (SUS) questionnaire. TEMPO identified learning modules that were relevant to the age, sex, imaging modality, and body part or organ system of the patient being viewed by the radiologist on the simulated clinical work station. Users expressed a high degree of satisfaction with the system's design and user interface. TEMPO enables just-in-time learning in radiology, and can be extended to create a fully functional learning management system for point-of-care learning in radiology.

  9. Informatics in radiology: evaluation of an e-learning platform for teaching medical students competency in ordering radiologic examinations.

    PubMed

    Marshall, Nina L; Spooner, Muirne; Galvin, P Leo; Ti, Joanna P; McElvaney, N Gerald; Lee, Michael J

    2011-01-01

    A preliminary audit of orders for computed tomography was performed to evaluate the typical performance of interns ordering radiologic examinations. According to the audit, the interns showed only minimal improvement after 8 months of work experience. The online radiology ordering module (ROM) program included baseline assessment of student performance (part I), online learning with the ROM (part II), and follow-up assessment of performance with simulated ordering with the ROM (part III). A curriculum blueprint determined the content of the ROM program, with an emphasis on practical issues, including provision of logistic information, clinical details, and safety-related information. Appropriate standards were developed by a committee of experts, and detailed scoring systems were devised for assessment. The ROM program was successful in addressing practical issues in a simulated setting. In the part I assessment, the mean score for noting contraindications for contrast media was 24%; this score increased to 59% in the part III assessment (P = .004). Similarly, notification of methicillin-resistant Staphylococcus aureus status and pregnancy status and provision of referring physician contact information improved significantly. The quality of the clinical notes was stable, with good initial scores. Part III testing showed overall improvement, with the mean score increasing from 61% to 76% (P < .0001). In general, medical students lack the core knowledge that is needed for good-quality ordering of radiology services, and the experience typically afforded to interns does not address this lack of knowledge. The ROM program was a successful intervention that resulted in statistically significant improvements in the quality of radiologic examination orders, particularly with regard to logistic and radiation safety issues.

  10. Analysis of operation UPSHOT-KNOTHOLE nuclear test BADGER radiological and meteorological data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quinn, V.E.

    1986-04-01

    This report describes the Weather Service Nuclear Support Office (WSNSO) analyses of the radiological and meteorological data collected for the BADGER nuclear test of Operation UPSHOT-KNOTHOLE. Inconsistencies in the radiological data and their resolution are discussed. The methods of normalizing the radiological data to a standard time, of converting the aerial data to equivalent ground-level values, and of estimating fallout-arrival times are presented. The meteorological situations on event day and the following day are described. A comparison of the WSNSO fallout analysis with an analysis performed during the 1950's is presented. The radiological data used to derive the WSNSO falloutmore » pattern are tabulated in an appendix.« less

  11. Occupational necessity and educational invention: resident teaching of radiologic technologists.

    PubMed

    Gunderman, Richard B; Fraley, Ronald; Jackson, Valerie; Robinson, Susan; Williamson, Kenneth

    2003-04-01

    Radiology faces a severe and growing shortage of radiologic technologists. One way of redressing this problem is to improve the quality of education provided to radiologic technology students. Yet growing clinical demands increasingly erode faculty time for teaching. This study examined whether radiology residents could provide equivalent instruction in radiologic technology at lower cost, and whether such experience could enhance residents' interest in teaching as part of their careers. Course evaluation forms completed by the students in a required radiologic pathology course were reviewed, and student-reported faculty and resident performances in teaching were compared. Residents also were surveyed for their reactions to the experience of teaching this course. Ninety percent of students (27 of 30) either agreed or strongly agreed that the course was well taught by radiology faculty members, and 97% (29 of 30) either agreed or strongly agreed that the course was well taught by radiology residents. The total direct cost of instruction by radiology residents was 73% lower than the cost of instruction by faculty. Residents who participated in teaching found the experience worthwhile, and they described a wide variety of personal and educational benefits. Involving radiology residents in teaching can help redress the growing shortage of radiologic technologists, relieve some of the pressure on faculty time, and contribute to the professional development of the next generation of radiologists.

  12. Real-time stereographic display of volumetric datasets in radiology

    NASA Astrophysics Data System (ADS)

    Wang, Xiao Hui; Maitz, Glenn S.; Leader, J. K.; Good, Walter F.

    2006-02-01

    A workstation for testing the efficacy of stereographic displays for applications in radiology has been developed, and is currently being tested on lung CT exams acquired for lung cancer screening. The system exploits pre-staged rendering to achieve real-time dynamic display of slabs, where slab thickness, axial position, rendering method, brightness and contrast are interactively controlled by viewers. Stereo presentation is achieved by use of either frame-swapping images or cross-polarizing images. The system enables viewers to toggle between alternative renderings such as one using distance-weighted ray casting by maximum-intensity-projection, which is optimal for detection of small features in many cases, and ray casting by distance-weighted averaging, for characterizing features once detected. A reporting mechanism is provided which allows viewers to use a stereo cursor to measure and mark the 3D locations of specific features of interest, after which a pop-up dialog box appears for entering findings. The system's impact on performance is being tested on chest CT exams for lung cancer screening. Radiologists' subjective assessments have been solicited for other kinds of 3D exams (e.g., breast MRI) and their responses have been positive. Objective estimates of changes in performance and efficiency, however, must await the conclusion of our study.

  13. Paranasal sinus mucoceles: our clinical experiments

    PubMed Central

    Topdag, Murat; Iseri, Mete; Sari, Fatih; Erdogan, Selvet; Keskin, I Gurkan

    2015-01-01

    Objectives: We present the clinical and radiological features, treatment protocols, and medium-long-term results of our patients following surgery for paranasal sinus mucocele, along with a review of the relevant literature. Materials and methods: A total of 18 patients (11 women and 7 men) who underwent surgery for paranasal sinus mucocele at Kocaeli University Faculty of Medicine, Department of Otolaryngology, between 2006 and 2013 were examined retrospectively. The mean patient age was 41 (range 4-73). Demographic and radiological features, symptoms, treatment protocols, and postoperative outcomes were recorded. Results: The most frequently affected sinus was the maxillary sinus (n=9, 50%) followed by the frontal sinus (n=6, 33%) and sphenoidal sinus (n=3, 16%). The main symptom was headache. Endoscopic marsupialization of the mucocele was applied in all 18 patients, while frontal sinus exploration with the osteoplastic flap procedure was performed in one patient and the Caldwell-Luc operation was performed in another patient. The Caldwell-Luc procedure was subsequently required in one patient (6%) and endoscopic revision surgery was required in another patient (6%). Conclusion: Sinus mucocele that enlarges, eroding the surrounding bone tissue, and induces various clinical symptoms due to the impression of the expansile mass, is treated surgically, and must be planned carefully to prevent serious complications. PMID:26770462

  14. Improved understanding of human anatomy through self-guided radiological anatomy modules.

    PubMed

    Phillips, Andrew W; Smith, Sandy G; Ross, Callum F; Straus, Christopher M

    2012-07-01

    To quantifiably measure the impact of self-instructed radiological anatomy modules on anatomy comprehension, demonstrated by radiology, gross, and written exams. Study guides for independent use that emphasized structural relationships were created for use with two online radiology atlases. A guide was created for each module of the first year medical anatomy course and incorporated as an optional course component. A total of 93 of 96 eligible students participated. All exams were normalized to control for variances in exam difficulty and body region tested. An independent t-test was used to compare overall exam scores with respect to guide completion or incompletion. To account for aptitude differences between students, a paired t-test of each student's exam scores with and without completion of the associated guide was performed, thus allowing students to serve as their own controls. Twenty-one students completed no study guides; 22 completed all six guides; and 50 students completed between one and five guides. Aggregate comparisons of all students' exam scores showed significantly improved mean performance when guides were used (radiology, 57.8% [percentile] vs. 45.1%, P < .001; gross, 56.9% vs. 46.5%, P = .001; written, 57.8% vs. 50.2%, P = .011). Paired comparisons among students who completed between one and five guides demonstrated significantly higher mean practical exam scores when guides were used (radiology, 49.3% [percentile] vs. 36.0%, P = .001; gross, 51.5% vs. 40.4%, P = .005), but not higher written scores. Radiological anatomy study guides significantly improved anatomy comprehension on radiology, gross, and written exams. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  15. Radiology Physician Extenders: A Literature Review of the History and Current Roles of Physician Extenders in Medical Imaging.

    PubMed

    Sanders, Vicki L; Flanagan, Jennifer

    2015-01-01

    The purpose of the literature review was to assess the origins of radiology physician extenders and examine the current roles found in the literature of advanced practice physician extenders within medical imaging. Twenty-six articles relating to physician assistants (PAs), nurse practitioners (NPs), radiologist assistants (RAs), and nuclear medicine advanced associates (NMAAs) were reviewed to discern similarities and differences in history, scope of practice, and roles in the medical imaging field. The literature showed PAs and NPs are working mostly in interventional radiology. PAs, NPs, and RAs perform similar tasks in radiology, including history and physicals, evaluation and management, preprocedure work-up, obtaining informed consent, initial observations/reports, and post-procedure follow-up. NPs and PAs perform a variety of procedures but most commonly vascular access, paracentesis, and thoracentesis. RAs perform gastrointestinal, genitourinary, nonvascular invasive fluoroscopy procedures, and vascular access procedures. The review revealed NMAAs are working in an advanced role, but no specific performances of procedures was found in the literature, only suggested tasks and clinical competencies. PAs, NPs, and RAs are currently the three main midlevel providers used in medical imaging. These midlevel providers are being used in a variety of ways to increase the efficiency of the radiologist and provide diagnostic and therapeutic radiologic procedures to patients. NMAAs are being used in medical imaging but little literature is available on current roles in clinical practice. More research is needed to assess the exact procedures and duties being performed by these medical imaging physician extenders.

  16. [Case-based interactive PACS learning: introduction of a new concept for radiological education of students].

    PubMed

    Scherer, A; Kröpil, P; Heusch, P; Buchbender, C; Sewerin, P; Blondin, D; Lanzman, R S; Miese, F; Ostendorf, B; Bölke, E; Mödder, U; Antoch, G

    2011-11-01

    Medical curricula are currently being reformed in order to establish superordinated learning objectives, including, e.g., diagnostic, therapeutic and preventive competences. This requires a shifting from traditional teaching methods towards interactive and case-based teaching concepts. Conceptions, initial experiences and student evaluations of a novel radiological course Co-operative Learning In Clinical Radiology (CLICR) are presented in this article. A novel radiological teaching course (CLICR course), which combines different innovative teaching elements, was established and integrated into the medical curriculum. Radiological case vignettes were created for three clinical teaching modules. By using a PC with PACS (Picture Archiving and Communication System) access, web-based databases and the CASUS platform, a problem-oriented, case-based and independent way of learning was supported as an adjunct to the well established radiological courses and lectures. Student evaluations of the novel CLICR course and the radiological block course were compared. Student evaluations of the novel CLICR course were significantly better compared to the conventional radiological block course. Of the participating students 52% gave the highest rating for the novel CLICR course concerning the endpoint overall satisfaction as compared to 3% of students for the conventional block course. The innovative interactive concept of the course and the opportunity to use a web-based database were favorably accepted by the students. Of the students 95% rated the novel course concept as a substantial gain for the medical curriculum and 95% also commented that interactive working with the PACS and a web-based database (82%) promoted learning and understanding. Interactive, case-based teaching concepts such as the presented CLICR course are considered by both students and teachers as useful extensions to the radiological course program. These concepts fit well into competence-oriented curricula.

  17. How Visual Search Relates to Visual Diagnostic Performance: A Narrative Systematic Review of Eye-Tracking Research in Radiology

    ERIC Educational Resources Information Center

    van der Gijp, A.; Ravesloot, C. J.; Jarodzka, H.; van der Schaaf, M. F.; van der Schaaf, I. C.; van Schaik, J. P.; ten Cate, Th. J.

    2017-01-01

    Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review of eye-tracking literature in the radiology…

  18. Otogenic Meningitis: A Comparison of Diagnostic Performance of Surgery and Radiology.

    PubMed

    Bruschini, Luca; Fortunato, Simona; Tascini, Carlo; Ciabotti, Annalisa; Leonildi, Alessandro; Bini, Belinda; Giuliano, Simone; Abbruzzese, Arturo; Berrettini, Stefano; Menichetti, Francesco

    2017-01-01

    Development of intracranial complications from middle ear infections might be difficult to diagnose. We compared radiological and surgical findings of 26 patients affected by otogenic meningitis. Results of our analysis showed that surgery is more reliable than imaging in revealing bone defects. Therefore, suggest that surgery be performed for diagnosis and eventual management of all cases of suspected otogenic meningitis.

  19. An honest day's work: pay for performance in a pediatric radiology department.

    PubMed

    Bisset, George S

    2017-06-01

    Compensation models in radiology take a variety of forms, but regardless of practice type, successful models must reward productivity, be simple, and epitomize fairness. The ideal model should also be flexible enough to transition, based upon the changing strategic goals of a department. The plan should be constructed around rewarding the behaviors that the organization values. In this minisymposium article the author presents the value of different types of compensation plans and discusses advantages and disadvantages. Finally, the author presents a pay-for-performance model that has had long-term success at a private-turned-academic practice in pediatric radiology.

  20. Informatics in radiology: automated Web-based graphical dashboard for radiology operational business intelligence.

    PubMed

    Nagy, Paul G; Warnock, Max J; Daly, Mark; Toland, Christopher; Meenan, Christopher D; Mezrich, Reuben S

    2009-11-01

    Radiology departments today are faced with many challenges to improve operational efficiency, performance, and quality. Many organizations rely on antiquated, paper-based methods to review their historical performance and understand their operations. With increased workloads, geographically dispersed image acquisition and reading sites, and rapidly changing technologies, this approach is increasingly untenable. A Web-based dashboard was constructed to automate the extraction, processing, and display of indicators and thereby provide useful and current data for twice-monthly departmental operational meetings. The feasibility of extracting specific metrics from clinical information systems was evaluated as part of a longer-term effort to build a radiology business intelligence architecture. Operational data were extracted from clinical information systems and stored in a centralized data warehouse. Higher-level analytics were performed on the centralized data, a process that generated indicators in a dynamic Web-based graphical environment that proved valuable in discussion and root cause analysis. Results aggregated over a 24-month period since implementation suggest that this operational business intelligence reporting system has provided significant data for driving more effective management decisions to improve productivity, performance, and quality of service in the department.

  1. Quality improvement in multidisciplinary cancer teams: an investigation of teamwork and clinical decision-making and cross-validation of assessments.

    PubMed

    Lamb, B W; Sevdalis, N; Mostafid, H; Vincent, C; Green, J S A

    2011-12-01

    Teamworking and clinical decision-making are important in multidisciplinary cancer teams (MDTs). Our objective is to assess the quality of information presentation and MDT members' contribution to decision-making via expert observation and self-report, aiming to cross-validate the two methods and assess the insight of MDT members into their own team performance. Behaviors were scored using (i) a validated observational tool employing Likert scales with objective anchors, and (ii) a 29-question online self-report tool. Data were collected from observation of 164 cases in five MDTs, and 47 surveys from MDT members (response rate 70%). Presentation of information (case history, radiological, pathological, comorbidities, psychosocial, and patients' views) and quality of contribution to decision-making of MDT members (surgeons, oncologists, radiologists, pathologists, nurses, and MDT coordinators) were analyzed via descriptive statistics and the Jonckheere-Terpstra test. Correlation between observational and self-report assessments was assessed with Spearman's correlations. Quality of information presentation: Case histories and radiology information rated highest; patients' views and comorbidities/psychosocial issues rated lowest (observed: Z = 14.80, P ≤ 0.001; self-report: Z = 3.70, P < 0.001). Contribution to decision-making: Surgeons and oncologists rated highest, nurses and MDT coordinators rated lowest, and others in between (observed: Z = 20.00, P ≤ 0.001; self-report: Z = 8.10, P < 0.001). Correlations between observational and self-report assessments: Median Spearman's rho = 0.74 (range = 0.66-0.91; P < 0.05). The quality of teamworking and clinical decision-making in MDTs can reliably be assessed using observational and self-report metrics. MDT members have good insight into their own team performance. Such robust assessment methods could provide the basis of a toolkit for MDT team evaluation and improvement.

  2. Implementation of a Longitudinal Introduction to Radiology Course During Internship Year Improves Diagnostic Radiology Residents' Academic and Clinical Skills: A Canadian Experience.

    PubMed

    Darras, Kathryn E; Worthington, Anne; Russell, David; Hou, Daniel J; Forster, Bruce B; Hague, Cameron J; Mar, Colin; Chang, Silvia D

    2016-07-01

    In order to ease the transition from internship to diagnostic radiology residency, a year-long didactic introduction to radiology course was offered to post-graduate year one (PGY-1) diagnostic radiology residents during their internship, which consisted of 27 hours of lecture over 9 months. The purpose of this study was to determine the quantitative and qualitative educational value of this course and its effect with respect to on-call preparedness. Two consecutive cohorts of Diagnostic Radiology residents were included: the first cohort (PGY-1s in 2011-2012) did not participate in the new course (Old Curriculum Residents) and the second cohort (PGY-1s in 2012-2013) completed the new course (New Curriculum Residents). These two cohorts were compared both qualitatively and quantitatively. Scores were compared from the standardized Canadian National Pre-Call Observed Standardized Clinical Examination and American College of Radiology Diagnostic Radiology In-Training examination, which are taken in the PGY-2 year, at months 5 and 7, respectively. In addition, staff observation of on-call resident performance and resident self-reported preparedness were considered. Cohorts were compared using Mann-Whitney U test with significance defined as P value <0.05. P values from 0.05 to 0.10 were noted as possibly significant and further analyzed using a Cohen d test where the difference was determined to be small (0.2), medium (0.5), or large (0.8). New Curriculum Residents reported that the content of the PGY1 curriculum was more appropriate than the old curriculum to prepare them for call in PGY2 (P = 0.013). New Curriculum Residents scored better than the Old Curriculum Residents on the Diagnostic Radiology In-Training examination (P = 0.039) and on the emergency cases of the Canadian National Pre-Call Observed Standardized Clinical Examination (P = 0.035). Staff radiologists, who were not blinded, reported that the New Curriculum Residents were better prepared for daytime (P = 0.006) and overnight (P = 0.008) independent call were better prepared to perform common ultrasound examinations alone (P = 0.049), and required less guidance while on call for nine competency areas. There was, however, no statistical difference between the residents' self-reported preparedness for independent call. Participation in a lecture-based introductory radiology curriculum during the PGY-1 internship year improved both radiology residents' preparedness for call and their performance in PGY-2. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Is Radiologic Evaluation Necessary to Find out Foreign Bodies in Nasal Cavity?

    PubMed

    Oh, Hoon; Min, Hyun Jin; Yang, Hoon Shik; Kim, Kyung Soo

    2016-01-01

    Although there were previous studies on the clinical aspects such as etiology, treatment modalities, studies regarding the necessity of radiologic evaluation for nasal foreign body were limited. The aim of this study is to evaluate the necessity and indication of radiologic evaluation for nasal foreign bodies. There are consecutive patients aged less than 10 years who presented with suspected foreign bodies in nasal cavity. We reviewed the patient's age and sex, including the methods of evaluation, management tools, and types of foreign bodies. There were 35 cases (11.4%) on whom radiographs were performed in the 24 uncooperative patients and 11 cooperative patients who were not identified with any foreign bodies via nasal endoscopy. Among them, only 4 cases had positive reports of foreign body and the others were normal radiologic findings. We suggest that the radiologic evaluation is always not necessary to find the location of nasal foreign bodies. It, however, should be performed in cases of negative findings of physical examination with anterior rhinoscopy or sinus endoscopy and unwitnessed foreign bodies to rule out metallic contents, especially button type battery.

  4. Radiation dose reduction: comparative assessment of publication volume between interventional and diagnostic radiology.

    PubMed

    Hansmann, Jan; Henzler, Thomas; Gaba, Ron C; Morelli, John N

    2017-01-01

    We aimed to quantify and compare awareness regarding radiation dose reduction within the interventional radiology and diagnostic radiology communities. Abstracts accepted to the annual meetings of the Society of Interventional Radiology (SIR), the Cardiovascular and Interventional Radiological Society of Europe (CIRSE), the Radiological Society of North America (RSNA), and the European Congress of Radiology (ECR) between 2005 and 2015 were analyzed using the search terms "interventional/computed tomography" and "radiation dose/radiation dose reduction." A PubMed query using the above-mentioned search terms for the years of 2005-2015 was performed. Between 2005 and 2015, a total of 14 520 abstracts (mean, 660±297 abstracts) and 80 614 abstracts (mean, 3664±1025 abstracts) were presented at interventional and diagnostic radiology meetings, respectively. Significantly fewer abstracts related to radiation dose were presented at the interventional radiology meetings compared with the diagnostic radiology meetings (162 abstracts [1% of total] vs. 2706 [3% of total]; P < 0.001). On average 15±7 interventional radiology abstracts (range, 6-27) and 246±105 diagnostic radiology abstracts (range, 112-389) pertaining to radiation dose were presented at each meeting. The PubMed query revealed an average of 124±39 publications (range, 79-187) and 1205±307 publications (range, 829-1672) related to interventional and diagnostic radiology dose reduction per year, respectively (P < 0.001). The observed increase in the number of abstracts regarding radiation dose reduction in the interventional radiology community over the past 10 years has not mirrored the increased volume seen within diagnostic radiology, suggesting that increased education and discussion about this topic may be warranted.

  5. Radiation dose reduction: comparative assessment of publication volume between interventional and diagnostic radiology

    PubMed Central

    Hansmann, Jan; Henzler, Thomas; Gaba, Ron C.; Morelli, John N.

    2017-01-01

    PURPOSE We aimed to quantify and compare awareness regarding radiation dose reduction within the interventional radiology and diagnostic radiology communities. METHODS Abstracts accepted to the annual meetings of the Society of Interventional Radiology (SIR), the Cardiovascular and Interventional Radiological Society of Europe (CIRSE), the Radiological Society of North America (RSNA), and the European Congress of Radiology (ECR) between 2005 and 2015 were analyzed using the search terms “interventional/computed tomography” and “radiation dose/radiation dose reduction.” A PubMed query using the above-mentioned search terms for the years of 2005–2015 was performed. RESULTS Between 2005 and 2015, a total of 14 520 abstracts (mean, 660±297 abstracts) and 80 614 abstracts (mean, 3664±1025 abstracts) were presented at interventional and diagnostic radiology meetings, respectively. Significantly fewer abstracts related to radiation dose were presented at the interventional radiology meetings compared with the diagnostic radiology meetings (162 abstracts [1% of total] vs. 2706 [3% of total]; P < 0.001). On average 15±7 interventional radiology abstracts (range, 6–27) and 246±105 diagnostic radiology abstracts (range, 112–389) pertaining to radiation dose were presented at each meeting. The PubMed query revealed an average of 124±39 publications (range, 79–187) and 1205±307 publications (range, 829–1672) related to interventional and diagnostic radiology dose reduction per year, respectively (P < 0.001). CONCLUSION The observed increase in the number of abstracts regarding radiation dose reduction in the interventional radiology community over the past 10 years has not mirrored the increased volume seen within diagnostic radiology, suggesting that increased education and discussion about this topic may be warranted. PMID:28287072

  6. Ineffective Leadership.

    PubMed

    Itri, Jason N; Lawson, Leslie M

    2016-07-01

    Radiology leaders can have a profound impact on the success and working environment of a radiology department, promoting core values and inspiring staff members to achieve the organization's mission. On the other hand, ineffective leaders can have a devastating effect on a radiology department by impairing communication among members, undermining staff commitment to the organization's success, and stifling the development of other staff members and leaders in the organization. One of the most important investments a radiology department can make is in identifying, cultivating, and promoting new leaders. The authors describe 13 habits and characteristics of new leaders that lead these individuals to address situations in both ineffective and counterproductive ways, impeding the performance of a radiology department and its capacity to play a meaningful role in shaping the future of radiology. New leaders must continually learn and improve their leadership skills if they are to avoid the destructive habits of ineffective leaders and successfully overcome the challenges facing radiology today. Senior leaders may also benefit from understanding the pitfalls that make leaders ineffective and should strive to continually improve their leadership skills given the critical role of leadership in the success of radiology departments. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Retrospective Analysis of Clinical Performance of an Estonian Speech Recognition System for Radiology: Effects of Different Acoustic and Language Models.

    PubMed

    Paats, A; Alumäe, T; Meister, E; Fridolin, I

    2018-04-30

    The aim of this study was to analyze retrospectively the influence of different acoustic and language models in order to determine the most important effects to the clinical performance of an Estonian language-based non-commercial radiology-oriented automatic speech recognition (ASR) system. An ASR system was developed for Estonian language in radiology domain by utilizing open-source software components (Kaldi toolkit, Thrax). The ASR system was trained with the real radiology text reports and dictations collected during development phases. The final version of the ASR system was tested by 11 radiologists who dictated 219 reports in total, in spontaneous manner in a real clinical environment. The audio files collected in the final phase were used to measure the performance of different versions of the ASR system retrospectively. ASR system versions were evaluated by word error rate (WER) for each speaker and modality and by WER difference for the first and the last version of the ASR system. Total average WER for the final version throughout all material was improved from 18.4% of the first version (v1) to 5.8% of the last (v8) version which corresponds to relative improvement of 68.5%. WER improvement was strongly related to modality and radiologist. In summary, the performance of the final ASR system version was close to optimal, delivering similar results to all modalities and being independent on user, the complexity of the radiology reports, user experience, and speech characteristics.

  8. A reliable and cost effective approach for radiographic monitoring in nutritional rickets.

    PubMed

    Chatterjee, D; Gupta, V; Sharma, V; Sinha, B; Samanta, S

    2014-04-01

    Radiological scoring is particularly useful in rickets, where pre-treatment radiographical findings can reflect the disease severity and can be used to monitor the improvement. However, there is only a single radiographic scoring system for rickets developed by Thacher and, to the best of our knowledge, no study has evaluated radiographic changes in rickets based on this scoring system apart from the one done by Thacher himself. The main objective of this study is to compare and analyse the pre-treatment and post-treatment radiographic parameters in nutritional rickets with the help of Thacher's scoring technique. 176 patients with nutritional rickets were given a single intramuscular injection of vitamin D (600 000 IU) along with oral calcium (50 mg kg(-1)) and vitamin D (400 IU per day) until radiological resolution and followed for 1 year. Pre- and post-treatment radiological parameters were compared and analysed statistically based on Thacher's scoring system. Radiological resolution was complete by 6 months. Time for radiological resolution and initial radiological score were linearly associated on regression analysis. The distal ulna was the last to heal in most cases except when the initial score was 10, when distal femur was the last to heal. Thacher's scoring system can effectively monitor nutritional rickets. The formula derived through linear regression has prognostic significance. The distal femur is a better indicator in radiologically severe rickets and when resolution is delayed. Thacher's scoring is very useful for monitoring of rickets. The formula derived through linear regression can predict the expected time for radiological resolution.

  9. Cost to the hospital of a clinical training program.

    PubMed

    Carney, M K; Keim, S T

    1978-01-01

    Programs for the training of radiologic technologists involving clinical training at a host hospital are growing rapidly. The objective of the study reported in this paper was to determine the cost to the hospital of supporting such clinical training. Information was collected by means of interviews with hospital administrative officials, clinical instructors and current and recent students. The thrust of the inquiry was toward hospital activities in the production of patient radiologic services. Specifically, questions dealt with the diversion of professional care from the hospital workload and the substitutability of student effort in the performance of professional duties associated with the implementation of the clinical training program. It appears that hosting a clinical training program does not increase hospital costs. There may in fact be a net benefit to the hospital. There was widespread agreement that the production of a student-instructor team more than offset the loss of output resulting from the diversion of staff personnel to instructional duties. Other costs--capital, supplies, breakage--do not appear to be major, and are possibly offset by benefits such as improved recruitment of technologists.

  10. Using the Monte Carlo technique to calculate dose conversion coefficients for medical professionals in interventional radiology

    NASA Astrophysics Data System (ADS)

    Santos, W. S.; Carvalho, A. B., Jr.; Hunt, J. G.; Maia, A. F.

    2014-02-01

    The objective of this study was to estimate doses in the physician and the nurse assistant at different positions during interventional radiology procedures. In this study, effective doses obtained for the physician and at points occupied by other workers were normalised by air kerma-area product (KAP). The simulations were performed for two X-ray spectra (70 kVp and 87 kVp) using the radiation transport code MCNPX (version 2.7.0), and a pair of anthropomorphic voxel phantoms (MASH/FASH) used to represent both the patient and the medical professional at positions from 7 cm to 47 cm from the patient. The X-ray tube was represented by a point source positioned in the anterior posterior (AP) and posterior anterior (PA) projections. The CC can be useful to calculate effective doses, which in turn are related to stochastic effects. With the knowledge of the values of CCs and KAP measured in an X-ray equipment, at a similar exposure, medical professionals will be able to know their own effective dose.

  11. Novel CT-based objective imaging biomarkers of long term radiation-induced lung damage.

    PubMed

    Veiga, Catarina; Landau, David; Devaraj, Anand; Doel, Tom; White, Jared; Ngai, Yenting; Hawkes, David J; McClelland, Jamie R

    2018-06-14

    and Purpose: Recent improvements in lung cancer survival have spurred an interest in understanding and minimizing long term radiation-induced lung damage (RILD). However, there is still no objective criteria to quantify RILD leading to variable reporting across centres and trials. We propose a set of objective imaging biomarkers to quantify common radiological findings observed 12-months after lung cancer radiotherapy (RT). Baseline and 12-month CT scans of 27 patients from a phase I/II clinical trial of isotoxic chemoradiation were included in this study. To detect and measure the severity of RILD, twelve quantitative imaging biomarkers were developed. These describe basic CT findings including parenchymal change, volume reduction and pleural change. The imaging biomarkers were implemented as semi-automated image analysis pipelines and assessed against visual assessment of the occurrence of each change. The majority of the biomarkers were measurable in each patient. Their continuous nature allows objective scoring of severity for each patient. For each imaging biomarker the cohort was split into two groups according to the presence or absence of the biomarker by visual assessment, testing the hypothesis that the imaging biomarkers were different in these two groups. All features were statistically significant except for rotation of the main bronchus and diaphragmatic curvature. The majority of the biomarkers were not strongly correlated with each other suggesting that each of the biomarkers is measuring a separate element of RILD pathology. We developed objective CT-based imaging biomarkers that quantify the severity of radiological lung damage after RT. These biomarkers are representative of typical radiological findings of RILD. Copyright © 2018. Published by Elsevier Inc.

  12. Activities carried out by the American College of Radiology in cooperation with the National Institute for Occupational Safety and Health. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1984-09-28

    Activities carried out by the American College of Radiology are described. Guidelines on radiographic techniques for radiological technicians were developed. Annual training sessions for technologists and physicians were conducted by the American College of Radiology Task Force on Pneumoconiosis. Regulations for performing chest x rays were reviewed. Program activities such as the 12-point International Labor Organization (ILO) classification scale for diagnosis of coal workers' pneumoconiosis, and the reporting form for use of the 1980 ILO classification system were reviewed. The American College of Radiology maintained liaison between NIOSH and other medical specialty societies such as the American College of Chestmore » Physicians, the College of American Pathologists, the American Medical Association, and the American Osteopathic College of Radiology. The American College of Radiology assisted NIOSH with the initiation, development, and maintenance of a quality control method to monitor and advise physicians on the reading of radiographs.« less

  13. Updates on Percutaneous Radiologic Gastrostomy/Gastrojejunostomy and Jejunostomy

    PubMed Central

    Park, Auh-Whan

    2010-01-01

    Gastrostomy placement for nutritional support for patients with inadequate oral intake has been attempted using surgical, endoscopic, and, more recently, percutaneous radiologically guided methods. Surgical gastrostomy has been superseded by both endoscopic and radiologic gastrostomy. We describe herein the indications, contraindications, patient preparations, techniques, complications, and aftercare with regard to radiologic gastrostomy. In addition, we discuss the available tube types and their perceived advantages. There remain some controversies regarding gastropexy performance and primary percutaneous gastrojejunostomy. Percutaneous jejunostomy is indicated for patients whose stomach is inaccessible for gastrostomy placement or for those who have had a previous gastrectomy. PMID:21103291

  14. Canadian Association of Radiologists White Paper on Artificial Intelligence in Radiology.

    PubMed

    Tang, An; Tam, Roger; Cadrin-Chênevert, Alexandre; Guest, Will; Chong, Jaron; Barfett, Joseph; Chepelev, Leonid; Cairns, Robyn; Mitchell, J Ross; Cicero, Mark D; Poudrette, Manuel Gaudreau; Jaremko, Jacob L; Reinhold, Caroline; Gallix, Benoit; Gray, Bruce; Geis, Raym

    2018-05-01

    Artificial intelligence (AI) is rapidly moving from an experimental phase to an implementation phase in many fields, including medicine. The combination of improved availability of large datasets, increasing computing power, and advances in learning algorithms has created major performance breakthroughs in the development of AI applications. In the last 5 years, AI techniques known as deep learning have delivered rapidly improving performance in image recognition, caption generation, and speech recognition. Radiology, in particular, is a prime candidate for early adoption of these techniques. It is anticipated that the implementation of AI in radiology over the next decade will significantly improve the quality, value, and depth of radiology's contribution to patient care and population health, and will revolutionize radiologists' workflows. The Canadian Association of Radiologists (CAR) is the national voice of radiology committed to promoting the highest standards in patient-centered imaging, lifelong learning, and research. The CAR has created an AI working group with the mandate to discuss and deliberate on practice, policy, and patient care issues related to the introduction and implementation of AI in imaging. This white paper provides recommendations for the CAR derived from deliberations between members of the AI working group. This white paper on AI in radiology will inform CAR members and policymakers on key terminology, educational needs of members, research and development, partnerships, potential clinical applications, implementation, structure and governance, role of radiologists, and potential impact of AI on radiology in Canada. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Qualitative review of usability problems in health information systems for radiology.

    PubMed

    Dias, Camila Rodrigues; Pereira, Marluce Rodrigues; Freire, André Pimenta

    2017-12-01

    Radiology processes are commonly supported by Radiology Information System (RIS), Picture Archiving and Communication System (PACS) and other software for radiology. However, these information technologies can present usability problems that affect the performance of radiologists and physicians, especially considering the complexity of the tasks involved. The purpose of this study was to extract, classify and analyze qualitatively the usability problems in PACS, RIS and other software for radiology. A systematic review was performed to extract usability problems reported in empirical usability studies in the literature. The usability problems were categorized as violations of Nielsen and Molich's usability heuristics. The qualitative analysis indicated the causes and the effects of the identified usability problems. From the 431 papers initially identified, 10 met the study criteria. The analysis of the papers identified 90 instances of usability problems, classified into categories corresponding to established usability heuristics. The five heuristics with the highest number of instances of usability problems were "Flexibility and efficiency of use", "Consistency and standards", "Match between system and the real world", "Recognition rather than recall" and "Help and documentation", respectively. These problems can make the interaction time consuming, causing delays in tasks, dissatisfaction, frustration, preventing users from enjoying all the benefits and functionalities of the system, as well as leading to more errors and difficulties in carrying out clinical analyses. Furthermore, the present paper showed a lack of studies performed on systems for radiology, especially usability evaluations using formal methods of evaluation involving the final users. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Enqvist, Andreas; Koppal, Sanjeev

    2015-07-01

    A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for themore » purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)« less

  17. Survey of UK radiology trainees in the aftermath of ‘Modernising Medical Careers’

    PubMed Central

    2012-01-01

    Background Following implementation of Modernising Medical Careers (MMC) in the UK, potential radiology trainees must decide on their career and apply sooner than ever before. We aimed to determine whether current trainees were sufficiently informed to make an earlier career decision by comparing the early radiology experiences of Traditional and Foundation Trainees. Methods 344 radiology trainees were appointed through MMC in 2007/08. This cohort was surveyed online. Results Response rate was 174/344 (51%). Traditional Trainees made their career decision 2.6 years after graduation compared with 1.2 years for Foundation Trainees (57/167, 34%). Nearly half of responders (79/169, 47%) experienced no formal radiology teaching as undergraduates. Most trainees regularly attended radiology meetings, spent time in a radiology department and/or performed radiology research. Many trainees received no career advice specific to radiology (69/163, 42%) at any point prior to entering the specialty; this includes both formal and informal advice. Junior doctor experiences were more frequently cited as influencing career choice (98/164, 60%). An earlier career decision was associated with; undergraduate radiology projects (-0.72 years, p = 0.018), career advice (-0.63 years, p = 0.009) and regular attendance at radiology meetings (-0.65 years, p = 0.014). Conclusion Early experience of radiology enables trainees to make an earlier career decision, however current radiology trainees were not always afforded relevant experiences prior to entering training. Radiologists need to be more proactive in encouraging the next generation of trainees. PMID:23031228

  18. A clinical audit programme for diagnostic radiology: the approach adopted by the International Atomic Energy Agency.

    PubMed

    Faulkner, K; Järvinen, H; Butler, P; McLean, I D; Pentecost, M; Rickard, M; Abdullah, B

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to the clinical audit programme and the IAEA clinical audit protocol.

  19. A model to determine payments associated with radiology procedures.

    PubMed

    Mabotuwana, Thusitha; Hall, Christopher S; Thomas, Shiby; Wald, Christoph

    2017-12-01

    Across the United States, there is a growing number of patients in Accountable Care Organizations and under risk contracts with commercial insurance. This is due to proliferation of new value-based payment models and care delivery reform efforts. In this context, the business model of radiology within a hospital or health system context is shifting from a primary profit-center to a cost-center with a goal of cost savings. Radiology departments need to increasingly understand how the transactional nature of the business relates to financial rewards. The main challenge with current reporting systems is that the information is presented only at an aggregated level, and often not broken down further, for instance, by type of exam. As such, the primary objective of this research is to provide better visibility into payments associated with individual radiology procedures in order to better calibrate expense/capital structure of the imaging enterprise to the actual revenue or value-add to the organization it belongs to. We propose a methodology that can be used to determine technical payments at a procedure level. We use a proportion based model to allocate payments to individual radiology procedures based on total charges (which also includes non-radiology related charges). Using a production dataset containing 424,250 radiology exams we calculated the overall average technical charge for Radiology to be $873.08 per procedure and the corresponding average payment to be $326.43 (range: $48.27 for XR and $2750.11 for PET/CT) resulting in an average payment percentage of 37.39% across all exams. We describe how charges associated with a procedure can be used to approximate technical payments at a more granular level with a focus on Radiology. The methodology is generalizable to approximate payment for other services as well. Understanding payments associated with each procedure can be useful during strategic practice planning. Charge-to-total charge ratio can be used to approximate radiology payments at a procedure level. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Incidence of Radiologically Isolated Syndrome: A Population-Based Study.

    PubMed

    Forslin, Y; Granberg, T; Jumah, A Antwan; Shams, S; Aspelin, P; Kristoffersen-Wiberg, M; Martola, J; Fredrikson, S

    2016-06-01

    Incidental MR imaging findings resembling MS in asymptomatic individuals, fulfilling the Okuda criteria, are termed "radiologically isolated syndrome." Those with radiologically isolated syndrome are at high risk of their condition converting to MS. The epidemiology of radiologically isolated syndrome remains largely unknown, and there are no population-based studies, to our knowledge. Our aim was to study the population-based incidence of radiologically isolated syndrome in a high-incidence region for MS and to evaluate the effect on radiologically isolated syndrome incidence when revising the original radiologically isolated syndrome criteria by using the latest radiologic classification for dissemination in space. All 2272 brain MR imaging scans in 1907 persons obtained during 2013 in the Swedish county of Västmanland, with a population of 259,000 inhabitants, were blindly evaluated by a senior radiologist and a senior neuroradiologist. The Okuda criteria for radiologically isolated syndrome were applied by using both the Barkhof and Swanton classifications for dissemination in space. Assessments of clinical data were performed by a radiology resident and a senior neurologist. The cumulative incidence of radiologically isolated syndrome was 2 patients (0.1%), equaling an incidence rate of 0.8 cases per 100,000 person-years, in a region with an incidence rate of MS of 10.2 cases per 100,000 person-years. There was no difference in the radiologically isolated syndrome incidence rate when applying a modified version of the Okuda criteria by using the newer Swanton classification for dissemination in space. Radiologically isolated syndrome is uncommon in a high-incidence region for MS. Adapting the Okuda criteria to use the dissemination in space-Swanton classification may be feasible. Future studies on radiologically isolated syndrome may benefit from a collaborative approach to ensure adequate numbers of participants. © 2016 by American Journal of Neuroradiology.

  1. Radiology Exposure in the Undergraduate Curriculum: A Medical Student Perspective on Quality and Opportunities for Positive Change.

    PubMed

    Visscher, Kari L; Faden, Lisa; Nassrallah, Georges; Speer, Stacey; Wiseman, Daniele

    2017-08-01

    This article is a continuation of a qualitative study designed to explore how radiology exposures can impact medical student opinions and perceptions of radiology and radiologists. We focused on: 1) conducting a radiology exposure inventory from the perspective of the medical student; 2) student evaluation of the quality of the radiology exposures and suggestions for positive change; and 3) development of a framework to address the needs of medical students as it relates to radiology education in the undergraduate medical curriculum. Research methodology and design for this qualitative study were described in detail in a previous article by Visscher et al [1]. Participants included 28 medical students; 18 were in medical school years 1 and 2 (preclerkship), and 10 were in years 3 and 4 (clerkship). Specific to the focus of this article, the data revealed 3 major findings: 1) multiple exposures to radiology exist, and they are received and valued differently depending on the medical student's stage of professional development; 2) medical students value radiology education and want their radiology exposure to be comprehensive and high quality; 3) Medical students have constructive suggestions for improving the quality of both formal and informal radiology exposures. Performing a radiology exposure inventory from a medical student perspective is a useful way to explore how students receive and value radiology instruction. Medical students want a more comprehensive radiology education that can be summarized using the 5 C's of Radiology Education framework. The 5 C's (curriculum, coaching, collaborating, career and commitment) reflect medical students' desires to learn content that will support them in clinical practice, be supported in their professional development, and have the necessary information to make informed career decisions. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  2. Imaging informatics for consumer health: towards a radiology patient portal

    PubMed Central

    Arnold, Corey W; McNamara, Mary; El-Saden, Suzie; Chen, Shawn; Taira, Ricky K; Bui, Alex A T

    2013-01-01

    Objective With the increased routine use of advanced imaging in clinical diagnosis and treatment, it has become imperative to provide patients with a means to view and understand their imaging studies. We illustrate the feasibility of a patient portal that automatically structures and integrates radiology reports with corresponding imaging studies according to several information orientations tailored for the layperson. Methods The imaging patient portal is composed of an image processing module for the creation of a timeline that illustrates the progression of disease, a natural language processing module to extract salient concepts from radiology reports (73% accuracy, F1 score of 0.67), and an interactive user interface navigable by an imaging findings list. The portal was developed as a Java-based web application and is demonstrated for patients with brain cancer. Results and discussion The system was exhibited at an international radiology conference to solicit feedback from a diverse group of healthcare professionals. There was wide support for educating patients about their imaging studies, and an appreciation for the informatics tools used to simplify images and reports for consumer interpretation. Primary concerns included the possibility of patients misunderstanding their results, as well as worries regarding accidental improper disclosure of medical information. Conclusions Radiologic imaging composes a significant amount of the evidence used to make diagnostic and treatment decisions, yet there are few tools for explaining this information to patients. The proposed radiology patient portal provides a framework for organizing radiologic results into several information orientations to support patient education. PMID:23739614

  3. A contour-based shape descriptor for biomedical image classification and retrieval

    NASA Astrophysics Data System (ADS)

    You, Daekeun; Antani, Sameer; Demner-Fushman, Dina; Thoma, George R.

    2013-12-01

    Contours, object blobs, and specific feature points are utilized to represent object shapes and extract shape descriptors that can then be used for object detection or image classification. In this research we develop a shape descriptor for biomedical image type (or, modality) classification. We adapt a feature extraction method used in optical character recognition (OCR) for character shape representation, and apply various image preprocessing methods to successfully adapt the method to our application. The proposed shape descriptor is applied to radiology images (e.g., MRI, CT, ultrasound, X-ray, etc.) to assess its usefulness for modality classification. In our experiment we compare our method with other visual descriptors such as CEDD, CLD, Tamura, and PHOG that extract color, texture, or shape information from images. The proposed method achieved the highest classification accuracy of 74.1% among all other individual descriptors in the test, and when combined with CSD (color structure descriptor) showed better performance (78.9%) than using the shape descriptor alone.

  4. Experience with high-performance PACS

    NASA Astrophysics Data System (ADS)

    Wilson, Dennis L.; Goldburgh, Mitchell M.; Head, Calvin

    1997-05-01

    Lockheed Martin (Loral) has installed PACS with associated teleradiology in several tens of hospitals. The PACS that have been installed have been the basis for a shift to filmless radiology in many of the hospitals. the basic structure for the PACS and the teleradiology that is being used is outlined. The way that the PACS are being used in the hospitals is instructive. The three most used areas for radiology in the hospital are the wards including the ICU wards, the emergency room, and the orthopedics clinic. The examinations are mostly CR images with 20 percent to 30 percent of the examinations being CT, MR, and ultrasound exams. The PACS are being used to realize improved productivity for radiology and for the clinicians. For radiology the same staff is being used for 30 to 50 percent more workload. For the clinicians 10 to 20 percent of their time is being saved in dealing with radiology images. The improved productivity stems from the high performance of the PACS that has been designed and installed. Images are available on any workstation in the hospital within less than two seconds, even during the busiest hour of the day. The examination management functions to restrict the attention of any one user to the examinations that are of interest. The examination management organizes the workflow through the radiology department and the hospital, improving the service of the radiology department by reducing the time until the information from a radiology examination is available. The remaining weak link in the PACS system is transcription. The examination can be acquired, read, an the report dictated in much less than ten minutes. The transcription of the dictated reports can take from a few hours to a few days. The addition of automatic transcription services will remove this weak link.

  5. Online Radiology Reporting with Peer Review as a Learning and Feedback Tool in Radiology; Implementation, Validity, and Student Impressions.

    PubMed

    McEvoy, Fintan J; Shen, Nicholas W; Nielsen, Dorte H; Buelund, Lene E; Holm, Peter

    2017-02-01

    Communicating radiological reports to peers has pedagogical value. Students may be uneasy with the process due to a lack of communication and peer review skills or to their failure to see value in the process. We describe a communication exercise with peer review in an undergraduate veterinary radiology course. The computer code used to manage the course and deliver images online is reported, and we provide links to the executable files. We tested to see if undergraduate peer review of radiological reports has validity and describe student impressions of the learning process. Peer review scores for student-generated radiological reports were compared to scores obtained in the summative multiple choice (MCQ) examination for the course. Student satisfaction was measured using a bespoke questionnaire. There was a weak positive correlation (Pearson correlation coefficient = 0.32, p < 0.01) between peer review scores students received and the student scores obtained in the MCQ examination. The difference in peer review scores received by students grouped according to their level of course performance (high vs. low) was statistically significant (p < 0.05). No correlation was found between peer review scores awarded by the students and the scores they obtained in the MCQ examination (Pearson correlation coefficient = 0.17, p = 0.14). In conclusion, we have created a realistic radiology imaging exercise with readily available software. The peer review scores are valid in that to a limited degree they reflect student future performance in an examination. Students valued the process of learning to communicate radiological findings but do not fully appreciated the value of peer review.

  6. A cryptologic based trust center for medical images.

    PubMed Central

    Wong, S T

    1996-01-01

    OBJECTIVE: To investigate practical solutions that can integrate cryptographic techniques and picture archiving and communication systems (PACS) to improve the security of medical images. DESIGN: The PACS at the University of California San Francisco Medical Center consolidate images and associated data from various scanners into a centralized data archive and transmit them to remote display stations for review and consultation purposes. The purpose of this study is to investigate the model of a digital trust center that integrates cryptographic algorithms and protocols seamlessly into such a digital radiology environment to improve the security of medical images. MEASUREMENTS: The timing performance of encryption, decryption, and transmission of the cryptographic protocols over 81 volumetric PACS datasets has been measured. Lossless data compression is also applied before the encryption. The transmission performance is measured against three types of networks of different bandwidths: narrow-band Integrated Services Digital Network, Ethernet, and OC-3c Asynchronous Transfer Mode. RESULTS: The proposed digital trust center provides a cryptosystem solution to protect the confidentiality and to determine the authenticity of digital images in hospitals. The results of this study indicate that diagnostic images such as x-rays and magnetic resonance images could be routinely encrypted in PACS. However, applying encryption in teleradiology and PACS is a tradeoff between communications performance and security measures. CONCLUSION: Many people are uncertain about how to integrate cryptographic algorithms coherently into existing operations of the clinical enterprise. This paper describes a centralized cryptosystem architecture to ensure image data authenticity in a digital radiology department. The system performance has been evaluated in a hospital-integrated PACS environment. PMID:8930857

  7. Performance comparison of quantitative semantic features and lung-RADS in the National Lung Screening Trial

    NASA Astrophysics Data System (ADS)

    Li, Qian; Balagurunathan, Yoganand; Liu, Ying; Schabath, Matthew; Gillies, Robert J.

    2016-03-01

    Background: Lung-RADS is the new oncology classification guideline proposed by American College of Radiology (ACR), which provides recommendation for further follow up in lung cancer screening. However, only two features (solidity and size) are included in this system. We hypothesize that additional sematic features can be used to better characterize lung nodules and diagnose cancer. Objective: We propose to develop and characterize a systematic methodology based on semantic image traits to more accurately predict occurrence of cancerous nodules. Methods: 24 radiological image traits were systematically scored on a point scale (up to 5) by a trained radiologist, and lung-RADS was independently scored. A linear discriminant model was used on the semantic features to access their performance in predicting cancer status. The semantic predictors were then compared to lung-RADS classification in 199 patients (60 cancers, 139 normal controls) obtained from the National Lung Screening Trial. Result: There were different combinations of semantic features that were strong predictors of cancer status. Of these, contour, border definition, size, solidity, focal emphysema, focal fibrosis and location emerged as top candidates. The performance of two semantic features (short axial diameter and contour) had an AUC of 0.945, and was comparable to that of lung-RADS (AUC: 0.871). Conclusion: We propose that a semantics-based discrimination approach may act as a complement to the lung-RADS to predict cancer status.

  8. Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures

    PubMed Central

    Chu, James C.H.; Hsi, Wen Chien; Hubbard, Lincoln; Zhang, Yunkai; Bernard, Damian; Reeder, Pamela; Lopes, Demetrius

    2005-01-01

    A hospital‐based magnetic guidance system (MGS) was installed to assist a physician in navigating catheters and guide wires during interventional cardiac and neurosurgical procedures. The objective of this study is to examine the performance of this magnetic field‐guided navigation system. Our results show that the system's radiological imaging components produce images with quality similar to that produced by other modern fluoroscopic devices. The system's magnetic navigation components also deflect the wire and catheter tips toward the intended direction. The physician, however, will have to oversteer the wire or catheter when defining the steering angle during the procedure. The MGS could be clinically useful in device navigation deflection and vessel access. PACS numbers: 07.55.Db, 07.85.‐m PMID:16143799

  9. Improved identification of noun phrases in clinical radiology reports using a high-performance statistical natural language parser augmented with the UMLS specialist lexicon.

    PubMed

    Huang, Yang; Lowe, Henry J; Klein, Dan; Cucina, Russell J

    2005-01-01

    The aim of this study was to develop and evaluate a method of extracting noun phrases with full phrase structures from a set of clinical radiology reports using natural language processing (NLP) and to investigate the effects of using the UMLS(R) Specialist Lexicon to improve noun phrase identification within clinical radiology documents. The noun phrase identification (NPI) module is composed of a sentence boundary detector, a statistical natural language parser trained on a nonmedical domain, and a noun phrase (NP) tagger. The NPI module processed a set of 100 XML-represented clinical radiology reports in Health Level 7 (HL7)(R) Clinical Document Architecture (CDA)-compatible format. Computed output was compared with manual markups made by four physicians and one author for maximal (longest) NP and those made by one author for base (simple) NP, respectively. An extended lexicon of biomedical terms was created from the UMLS Specialist Lexicon and used to improve NPI performance. The test set was 50 randomly selected reports. The sentence boundary detector achieved 99.0% precision and 98.6% recall. The overall maximal NPI precision and recall were 78.9% and 81.5% before using the UMLS Specialist Lexicon and 82.1% and 84.6% after. The overall base NPI precision and recall were 88.2% and 86.8% before using the UMLS Specialist Lexicon and 93.1% and 92.6% after, reducing false-positives by 31.1% and false-negatives by 34.3%. The sentence boundary detector performs excellently. After the adaptation using the UMLS Specialist Lexicon, the statistical parser's NPI performance on radiology reports increased to levels comparable to the parser's native performance in its newswire training domain and to that reported by other researchers in the general nonmedical domain.

  10. Characterization of optically stimulated luminescence dosemeters to measure organ doses in diagnostic radiology

    PubMed Central

    Endo, A; Katoh, T; Kobayashi, I; Joshi, R; Sur, J; Okano, T

    2012-01-01

    Objective The aim of this study was to assess the characteristics of an optically stimulated luminescence dosemeter (OSLD) for use in diagnostic radiology and to apply the OSLD in measuring the organ doses by panoramic radiography. Methods The dose linearity, energy dependency and angular dependency of aluminium oxide-based OSLDs were examined using an X-ray generator to simulate various exposure settings in diagnostic radiology. The organ doses were then measured by inserting the dosemeters into an anthropomorphic phantom while using three panoramic machines. Results The dosemeters demonstrated consistent dose linearity (coefficient of variation<1.5%) and no significant energy dependency (coefficient of variation<1.5%) under the applied exposure conditions. They also exhibited negligible angular dependency (≤10%). The organ doses of the X-ray as a result of panoramic imaging by three machines were calculated using the dosemeters. Conclusion OSLDs can be utilized to measure the organ doses in diagnostic radiology. The availability of these dosemeters in strip form proves to be reliably advantageous. PMID:22116136

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nichols, T.

    The Nuclear Forensics Analysis Center (NFAC) is part of Savannah River National Laboratory (SRNL) and is one of only two USG National Laboratories accredited to perform nuclear forensic analyses to the requirements of ISO 17025. SRNL NFAC is capable of analyzing nuclear and radiological samples from bulk material to ultra-trace samples. NFAC provides analytical support to the FBI's Radiological Evidence Examination Facility (REEF), which is located within SRNL. REEF gives the FBI the capability to perform traditional forensics on material that is radiological and/or is contaminated. SRNL is engaged in research and development efforts to improve the USG technical nuclearmore » forensics capabilities. Research includes improving predictive signatures and developing a database containing comparative samples.« less

  12. Home Fires

    MedlinePlus

    ... to the touch and lights that flicker. Portable Space Heaters Keep combustible objects at least three feet ... Radiological Dispersion Device Severe Weather Snowstorms & Extreme Cold Space Weather Thunderstorms & Lightning Tornadoes Tsunamis Volcanoes Wildfires Ready. ...

  13. Lean manufacturing and Toyota Production System terminology applied to the procurement of vascular stents in interventional radiology.

    PubMed

    de Bucourt, Maximilian; Busse, Reinhard; Güttler, Felix; Wintzer, Christian; Collettini, Federico; Kloeters, Christian; Hamm, Bernd; Teichgräber, Ulf K

    2011-08-01

    OBJECTIVES: To apply the economic terminology of lean manufacturing and the Toyota Production System to the procurement of vascular stents in interventional radiology. METHODS: The economic- and process-driven terminology of lean manufacturing and the Toyota Production System is first presented, including information and product flow as well as value stream mapping (VSM), and then applied to an interdisciplinary setting of physicians, nurses and technicians from different medical departments to identify wastes in the process of endovascular stent procurement in interventional radiology. RESULTS: Using the so-called seven wastes approach of the Toyota Production System (waste of overproducing, waiting, transport, processing, inventory, motion and waste of defects and spoilage) as well as further waste characteristics (gross waste, process and method waste, and micro waste), wastes in the process of endovascular stent procurement in interventional radiology were identified and eliminated to create an overall smoother process from the procurement as well as from the medical perspective. CONCLUSION: Economic terminology of lean manufacturing and the Toyota Production System, especially VSM, can be used to visualise and better understand processes in the procurement of vascular stents in interventional radiology from an economic point of view.

  14. Teaching, leadership, scholarly productivity, and level of activity in the chiropractic profession: a study of graduates of the Los Angeles College of Chiropractic radiology residency program

    PubMed Central

    Young, Kenneth J.; Siordia, Lawrence

    2012-01-01

    Objective The purpose of this study was to track the graduates of the Los Angeles College of Chiropractic (LACC) radiology residency program, review their scholarly productivity, and report those involved in teaching and leadership positions. Methods Former LACC residents’ career information was identified through publicly available electronic documents including Web sites and social media. PubMed and the Index to Chiropractic Literature databases were searched for chiropractic graduate job surveys, and proportional comparisons were made between the career paths of LACC radiology residency graduates and those of non–residency-trained chiropractors. Results Of 47 former LACC residents, 28 (60%) have or previously had careers in tertiary (chiropractic) education; and 12 (26%) have attained a department chair position or higher at tertiary teaching institutions. Twenty-two (47%) have or previously had private radiology practices, whereas 11 (23%) have or previously had clinical chiropractic practices. Often, residency graduates hold or have held 2 of these positions at once; and one, all 3. Chapters or books were authored by 13 (28%). Conclusion Radiology residency LACC graduates are professionally active, particularly in education, and demonstrate scholarly productivity. PMID:23966885

  15. Facilitating process changes in meal delivery and radiological testing to improve inpatient insulin timing using six sigma method.

    PubMed

    Yamamoto, J Jay; Malatestinic, Bill; Lehman, Angela; Juneja, Rattan

    2010-01-01

    The objective of this project was to improve the timing of inpatient insulin administration related to meal delivery and the scheduling of radiology tests by Lean Six Sigma method. A multidisciplinary hospital team and a Six Sigma team from a pharmaceutical manufacturer collaborated to evaluate food delivery and radiology scheduling processes related to the timing of insulin administration. Key factors leading to problems within each system were addressed to improve the efficiency of each process while improving the timeliness of glucose testing and insulin administration. Standardizing the food delivery schedule and utilizing scorecards to track on-time meal deliveries to the floor enabled nursing to more accurately administer insulin in coordination with the delivery of meals. Increasing communication and restricting the scheduling of inpatient procedures during mealtimes reduced disruptions to insulin administration. Data at 6 months postimplementation demonstrated that the institution met goals for most primary outcome metrics including increasing on-time meal delivery and the proportion of patients taking insulin scheduled for radiology tests during appropriate times. By implementing the recommendations identified via Lean Six Sigma, this collaborative effort improved the timing of inpatient insulin administration related to meal delivery and radiology testing.

  16. Radiological Protection and Nuclear Engineering Studies in Multi-MW Target Systems

    NASA Astrophysics Data System (ADS)

    Luis, Raul Fernandes

    Several innovative projects involving nuclear technology have emerged around the world in recent years, for applications such as spallation neutron sources, accelerator-driven systems for the transmutation of nuclear waste and radioactive ion beam (RIB) production. While the available neutron Wuxes from nuclear reactors did not increase substantially in intensity over the past three decades, the intensities of neutron sources produced in spallation targets have increased steadily, and should continue to do so during the 21st century. Innovative projects like ESS, MYRRHA and EURISOL lie at the forefront of the ongoing pursuit for increasingly bright neutron sources; driven by proton beams with energies up to 2 GeV and intensities up to several mA, the construction of their proposed facilities involves complex Nuclear Technology and Radiological Protection design studies executed by multidisciplinary teams of scientists and engineers from diUerent branches of Science. The intense neutron Wuxes foreseen for those facilities can be used in several scientiVc research Velds, such as Nuclear Physics and Astrophysics, Medicine and Materials Science. In this work, the target systems of two facilitites for the production of RIBs using the Isotope Separation On-Line (ISOL) method were studied in detail: ISOLDE, operating at CERN since 1967, and EURISOL, the next-generation ISOL facility to be built in Europe. For the EURISOL multi-MW target station, a detailed study of Radiological Protection was carried out using the Monte Carlo code FLUKA. Simulations were done to assess neutron Wuences, Vssion rates, ambient dose equivalent rates during operation and after shutdown and the production of radioactive nuclei in the targets and surrounding materials. DiUerent materials were discussed for diUerent components of the target system, aiming at improving its neutronics performance while keeping the residual activities resulting from material activation as low as possible. The second goal of this work was to perform an optimisation study for the ISOLDE neutron converter and Vssion target system. The target system was simulated using FLUKA and the cross section codes TALYS and ABRABLA, with the objective of maximising the performance of the system for the production of pure beams of neutron-rich isotopes, suppressing the contaminations by undesired neutron-deficient isobars. Two alternative target systems were proposed in the optimisation studies; the simplest of the two, with some modiVcations, was built as a prototype and tested at ISOLDE. The experimental results clearly show that it is possible, with simple changes in the layouts of the target systems, to produce purer beams of neutron-rich isotopes around the doubly magic nuclei 78Ni and 132Sn. A study of Radiological Protection was also performed, comparing the performances of the prototype target system and the standard ISOLDE target system. None

  17. Brainstem ischemic lesions on MRI in children with tuberculous meningitis: with diffusion weighted confirmation.

    PubMed

    van der Merwe, Dirk Johannes; Andronikou, Savvas; Van Toorn, Ronald; Pienaar, Manana

    2009-08-01

    The Western Cape in South Africa has one of the highest incidences of tuberculous meningitis (TBM) in the world. Despite therapy, the outcome in children with advanced TBM remains dismal. Magnetic resonance imaging (MRI) has been shown to be superior to computed tomography (CT) in demonstrating ischemia in TBM, especially of the brainstem. The objective of this study was to characterize brainstem lesions and association with clinical findings in children with TBM by using MRI. CT and multiplanar MRI scans were performed in 30 children with proven TBM. From this group, a subgroup with radiological ischemic changes of the brainstem were identified. Radiological findings in these patients were then correlated with severity of disease, motor deficit, and outcome after 6 months. Radiological brainstem abnormalities were identified in 14 out of 30 children. Thirty-eight brainstem lesions were confirmed to be ischemic. The severity of disease at presentation, degree of motor deficit, and developmental outcome after 6 months of the children with ischemic brainstem lesions was poorer compared to those children without brainstem involvement. However, both sensitivity and specificity of the MRI brainstem lesion detection for clinical outcome proved low. A significant percentage of children with TBM have ischemic brainstem lesions. These are poorly visualized on conventional CT. MRI scanning is more sensitive in detecting these lesions and localizing them. There appears to be some association between MRI-detected brainstem lesions and clinical outcome. The exact meaning of these lesions and their implication for the patient's management require further clarification.

  18. Nevada Test Site Environmental Report 2007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cathy Wills

    2008-09-01

    The Nevada Test Site Environmental Report 2007 (NTSER) was prepared to meet the information needs of the public and the requirements and guidelines of the U.S. Department of Energy (DOE) for annual site environmental reports. It was prepared by National Security Technologies, LLC (NSTec). This Executive Summary presents the purpose of the document, the major programs conducted at the Nevada Test Site (NTS), NTS key environmental initiatives, radiological releases and potential doses to the public resulting from site operations, a summary of nonradiological releases, implementation status of the NTS Environmental Management System, a summary of compliance with environmental regulations, pollutionmore » prevention and waste minimization accomplishments, and significant environmental accomplishments. Much of the content of this Executive Summary is also presented in a separate stand-alone pamphlet titled Nevada Test Site Environmental Report Summary 2007. This NTSER was prepared to satisfy DOE Order 231.1A, Environment, Safety and Health Reporting. Its purpose is to (1) report compliance status with environmental standards and requirements, (2) present results of environmental monitoring of radiological and nonradiological effluents, (3) report estimated radiological doses to the public from releases of radioactive material, (4) summarize environmental incidents of noncompliance and actions taken in response to them, (5) describe the NTS Environmental Management System and characterize its performance, and (6) highlight significant environmental programs and efforts. This report meets these objectives for the NTS and three offsite Nevada facilities mentioned in this report.« less

  19. Simulation based teaching in interventional radiology training: is it effective?

    PubMed

    Patel, R; Dennick, R

    2017-03-01

    To establish the educational effectiveness of simulation teaching in interventional radiology training. Electronic databases (MEDLINE, ERIC, Embase, OvidSP, and Cochrane Library) were searched (January 2000 to May 2015). Studies specifically with educational outcomes conducted on radiologists were eligible. All forms of simulation in interventional training were included. Data were extracted based on the population, intervention, comparison, and outcome (PICO) model. Kirkpatrick's hierarchy was used to establish educational intervention effectiveness. The quality of studies was assessed using the Cochrane risk of bias tool. Search resulted in 377 articles, of which 15 met the inclusion criteria. Thirteen of the 15 studies achieved level 2 of Kirkpatrick's hierarchy with only one reaching level 4. Statistically significant improvements in performance metrics as objective measures, demonstrating trainee competence were seen in 12/15 studies. Subjective improvements in confidence were noted in 13/15. Only one study demonstrated skills transferability and improvements in patient outcomes. Results demonstrate the relevance of simulated training to current education models in improving trainee competence; however, this is limited to the simulated environment as there is a lack of literature investigating its predictive validity and the effect on patient outcomes. The requirement for further research in this field is highlighted. Simulation is thus currently only deemed useful as an adjunct to current training models with the potential to play an influential role in the future of the interventional radiology training curriculum. Copyright © 2016. Published by Elsevier Ltd.

  20. Approaching the Practice Quality Improvement Project in Interventional Radiology.

    PubMed

    Reis, Stephen P; White, Benjamin; Sutphin, Patrick D; Pillai, Anil K; Kalva, Sanjeeva P; Toomay, Seth M

    2015-12-01

    An important component of maintenance of certification and quality improvement in radiology is the practice quality improvement (PQI) project. In this article, the authors describe several methodologies for initiating and completing PQI projects. Furthermore, the authors illustrate several tools that are vital in compiling, analyzing, and presenting data in an easily understandable and reproducible manner. Last, they describe two PQI projects performed in an interventional radiology division that have successfully improved the quality of care for patients. Using the DMAIC (define, measure, analyze, improve, control) quality improvement framework, interventional radiology throughput has been increased, to lessen mediport wait times from 43 to 8 days, and mediport infection rates have decreased from more than 2% to less than 0.4%. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. Identification of Long Bone Fractures in Radiology Reports Using Natural Language Processing to support Healthcare Quality Improvement.

    PubMed

    Grundmeier, Robert W; Masino, Aaron J; Casper, T Charles; Dean, Jonathan M; Bell, Jamie; Enriquez, Rene; Deakyne, Sara; Chamberlain, James M; Alpern, Elizabeth R

    2016-11-09

    Important information to support healthcare quality improvement is often recorded in free text documents such as radiology reports. Natural language processing (NLP) methods may help extract this information, but these methods have rarely been applied outside the research laboratories where they were developed. To implement and validate NLP tools to identify long bone fractures for pediatric emergency medicine quality improvement. Using freely available statistical software packages, we implemented NLP methods to identify long bone fractures from radiology reports. A sample of 1,000 radiology reports was used to construct three candidate classification models. A test set of 500 reports was used to validate the model performance. Blinded manual review of radiology reports by two independent physicians provided the reference standard. Each radiology report was segmented and word stem and bigram features were constructed. Common English "stop words" and rare features were excluded. We used 10-fold cross-validation to select optimal configuration parameters for each model. Accuracy, recall, precision and the F1 score were calculated. The final model was compared to the use of diagnosis codes for the identification of patients with long bone fractures. There were 329 unique word stems and 344 bigrams in the training documents. A support vector machine classifier with Gaussian kernel performed best on the test set with accuracy=0.958, recall=0.969, precision=0.940, and F1 score=0.954. Optimal parameters for this model were cost=4 and gamma=0.005. The three classification models that we tested all performed better than diagnosis codes in terms of accuracy, precision, and F1 score (diagnosis code accuracy=0.932, recall=0.960, precision=0.896, and F1 score=0.927). NLP methods using a corpus of 1,000 training documents accurately identified acute long bone fractures from radiology reports. Strategic use of straightforward NLP methods, implemented with freely available software, offers quality improvement teams new opportunities to extract information from narrative documents.

  2. Radiological Control Center (RADCC) Renaming Ceremony

    NASA Image and Video Library

    2017-03-31

    Consoles in the Radiological Control Center at NASA's Kennedy Space Center are seen during ceremonies to name the facility in honor of Randy Scott. A professional health physicist of more than 40 years, Scott served as the Florida spaceport's Radiation Protection Officer for 14 years until his death June 17, 2016. Located in the Neil Armstrong Operations and Checkout building, the Randall E. Scott Radiological Control Center is staffed by technical and radiological experts from NASA, the U.S. Department of Energy, the U.S. Air Force 45th Space Wing and the state of Florida. The group performs data collection and assessment functions supporting launch site and field data collection activities.

  3. Radiological Control Center (RADCC) Renaming Ceremony

    NASA Image and Video Library

    2017-03-31

    A portion of the Radiological Control Center at NASA's Kennedy Space Center is seen during ceremonies to name the facility in honor of Randy Scott. A professional health physicist of more than 40 years, Scott served as the Florida spaceport's Radiation Protection Officer for 14 years until his death June 17, 2016. Located in the Neil Armstrong Operations and Checkout building, the Randall E. Scott Radiological Control Center is staffed by technical and radiological experts from NASA, the U.S. Department of Energy, the U.S. Air Force 45th Space Wing and the state of Florida. The group performs data collection and assessment functions supporting launch site and field data collection activities.

  4. Evaluation of an open source tool for indexing and searching enterprise radiology and pathology reports

    NASA Astrophysics Data System (ADS)

    Kim, Woojin; Boonn, William

    2010-03-01

    Data mining of existing radiology and pathology reports within an enterprise health system can be used for clinical decision support, research, education, as well as operational analyses. In our health system, the database of radiology and pathology reports exceeds 13 million entries combined. We are building a web-based tool to allow search and data analysis of these combined databases using freely available and open source tools. This presentation will compare performance of an open source full-text indexing tool to MySQL's full-text indexing and searching and describe implementation procedures to incorporate these capabilities into a radiology-pathology search engine.

  5. Contrast reaction training in US radiology residencies: a COARDRI study.

    PubMed

    LeBedis, Christina A; Rosenkrantz, Andrew B; Otero, Hansel J; Decker, Summer J; Ward, Robert J

    To perform a survey-based assessment of current contrast reaction training in US diagnostic radiology residency programs. An electronic survey was distributed to radiology residency program directors from 9/2015-11/2015. 25.7% of programs responded. 95.7% of those who responded provide contrast reaction management training. 89.4% provide didactic lectures (occurring yearly in 71.4%). 37.8% provide hands-on simulation training (occurring yearly in 82.3%; attended by both faculty and trainees in 52.9%). Wide variability in contrast reaction education in US diagnostic radiology residency programs reveals an opportunity to develop and implement a national curriculum. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Pseudo-low Frequency Hearing Loss and Its Improvement After Treatment May Be Objective Signs of Significant Vascular Pathology in Patients With Pulsatile Tinnitus.

    PubMed

    Jeon, Hyoung Won; Kim, So Young; Choi, Byung Se; Bae, Yun Jung; Koo, Ja-Won; Song, Jae-Jin

    2016-10-01

    In patients with pulsatile tinnitus (PT), physical examination such as auscultation with head position change or digital compression over the ipsilateral jugular vein provides physicians with important information. However, objective diagnosis of PT is sometimes limited because 1) audible bruit is absent on auscultation in some patients, 2) abnormal vascular structures found in radiologic evaluation is not always pathognomonic because they can be found in asymptomatic subjects as well, and 3) although an objective diagnostic tool using transcanal sound recording has recently been introduced, special equipment is needed. In this regard, recent studies that have reported ipsilateral low-frequency hearing loss (LFHL) on pure-tone audiometry (PTA) in some patients with PT, and its recovery after successful management, prompted us to conduct a retrospective observational study on the characteristics of the audiometric profile, the association between the audiometric profile and radiologic findings, and pre- and posttreatment changes in low-frequency hearing thresholds in PT patients. We tested two hypotheses: PT patients with marked vascular pathologies located close to the cochlea may show ipsilateral pseudo-LFHL (PLFHL) because of the masking effects of the PT itself, and their PLFHL may disappear if their vascular pathology is successfully managed by surgical or endovascular intervention. Retrospective case review. Tertiary referral center. A total of 85 PT subjects who underwent both audiologic and radiologic examinations. All patients' pre- and posttreatment PTA thresholds and radiologic findings were analyzed. By comparing the LFHL (an ipsilateral hearing threshold greater than 10 dB HL at both 250 and 500 Hz or greater than 20 dB HL at either 250 or 500 Hz compared with the contralateral side) group and a non-LFHL group with regard to the incidence of vascular structural abnormalities, we evaluated the incidence of abnormal vascular structures in the head and neck between the LFHL and non-LFHL groups. In addition, by comparing pre- and posttreatment PTA thresholds of seven PT patients with ipsilateral LFHL, we further evaluated the changes in low-frequency hearing thresholds and their role as an objective sign for diagnosis and outcome evaluation. Of 85 patients, 22 (25.9%) presented with ipsilateral LFHL. Compared with patients without this condition, patients with ipsilateral LFHL showed a significantly higher rate of abnormal vascular structure. In addition, most of the radiologic abnormalities found in the LFHL group were highly suspicious causative lesions that are responsible for the perception of PT according to the previous literature. In eight PT patients with ipsilateral LFHL who underwent both pre- and posttreatment audiograms, the average posttreatment pure-tone threshold at 250 Hz showed significant improvement compared with the pretreatment threshold. PT patients presenting with ipsilateral LFHL have higher possibility of having a discrete vascular pathology near the cochlea on radiologic evaluation. As ipsilateral LFHL improves in most patients after treatment, LFHL in patients with PT may be PLFHL because of the masking effects of the pulsatile sound, and the changes in the low-frequency thresholds may be applicable for objective diagnosis and evaluation of the effects of the treatment.

  7. Distributed radiology clerkship for the core clinical year of medical school.

    PubMed

    Chew, Felix S

    2002-11-01

    The central role that diagnostic radiology has in the modern practice of medicine has not always been reflected in radiology's place in the curriculum. We developed a new radiology clerkship for undergraduate medical students during their core clinical year that was supported by Web technology. The assumptions underlying the design of the clerkship were that radiology is best learned from radiologists and that students are most receptive to learning radiology when it is related to concurrent patient care experiences. Beginning in May 2000, a required radiology clerkship experience was incorporated into the core clinical year at Wake Forest University School of Medicine. The core clinical year was organized into three 16-week blocks of clerkships. Two or four independent half-day radiology tutorial sessions were included with each clerkship block, and attended by all students in the block (approximately 35 students), regardless of their specific clerkship assignments. There were ten different radiology tutorials, each given three times during the year as students rotated through the clerkship blocks. Thus, each student attended a radiology tutorial session every four to eight weeks during the year. The topics covered during the tutorials were correlated with the content of the clerkship blocks and included adult and pediatric chest radiology, adult and pediatric abdominal radiology, body CT, neuroradiology, obstetric ultrasound, gynecologic ultrasound, osteoporosis, adult and pediatric fractures, mammography, and cervical spine trauma. The tutorials included pre- and post-test, lectures, case presentations, and sometimes tours of the radiology department. The educational emphasis was on pragmatic case-based learning exercises, development of verbal and visual vocabulary, and learning when and where to seek more information. To provide continuity and organization, Web-based curriculum materials were designed and implemented as a component of the clerkship. The home page of the Web site provided the schedule, faculty names, attendance and grading policies, course overview, and links to individual tutorials. The pages for individual tutorials included educational objectives, glossary of radiology terminology relevant to the subject, lecture slides and handouts, and teaching cases. All students had laptop computers and access to the academic network, but did not use them during the actual tutorial sessions. Implementation of the radiology clerkship required extensive negotiation with directors of other clerkships so that students could be released from their other responsibilities in order to attend the radiology tutorials. The radiology clerkship format has proven to be complex in its administration, with faculty and students on different schedules commuting to the radiology lecture hall from various locations. Extensive use of e-mail and communication via the Web site have been instrumental in reminding faculty and students of upcoming sessions. Preliminary evaluations have indicated that students liked the radiology sessions and learned a great deal, but disliked the scheduling and the lack of continuity. An evaluation of the curriculum and its components is ongoing.

  8. Trends in radiology and experimental research.

    PubMed

    Sardanelli, Francesco

    2017-01-01

    European Radiology Experimental , the new journal launched by the European Society of Radiology, is placed in the context of three general and seven radiology-specific trends. After describing the impact of population aging, personalized/precision medicine, and information technology development, the article considers the following trends: the tension between subspecialties and the unity of the discipline; attention to patient safety; the challenge of reproducibility for quantitative imaging; standardized and structured reporting; search for higher levels of evidence in radiology (from diagnostic performance to patient outcome); the increasing relevance of interventional radiology; and continuous technological evolution. The new journal will publish not only studies on phantoms, cells, or animal models but also those describing development steps of imaging biomarkers or those exploring secondary end-points of large clinical trials. Moreover, consideration will be given to studies regarding: computer modelling and computer aided detection and diagnosis; contrast materials, tracers, and theranostics; advanced image analysis; optical, molecular, hybrid and fusion imaging; radiomics and radiogenomics; three-dimensional printing, information technology, image reconstruction and post-processing, big data analysis, teleradiology, clinical decision support systems; radiobiology; radioprotection; and physics in radiology. The journal aims to establish a forum for basic science, computer and information technology, radiology, and other medical subspecialties.

  9. Modeling Urban Scenarios & Experiments: Fort Indiantown Gap Data Collections Summary and Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Archer, Daniel E.; Bandstra, Mark S.; Davidson, Gregory G.

    This report summarizes experimental radiation detector, contextual sensor, weather, and global positioning system (GPS) data collected to inform and validate a comprehensive, operational radiation transport modeling framework to evaluate radiation detector system and algorithm performance. This framework will be used to study the influence of systematic effects (such as geometry, background activity, background variability, environmental shielding, etc.) on detector responses and algorithm performance using synthetic time series data. This work consists of performing data collection campaigns at a canonical, controlled environment for complete radiological characterization to help construct and benchmark a high-fidelity model with quantified system geometries, detector response functions,more » and source terms for background and threat objects. This data also provides an archival, benchmark dataset that can be used by the radiation detection community. The data reported here spans four data collection campaigns conducted between May 2015 and September 2016.« less

  10. Radiological interventions in malignant biliary obstruction

    PubMed Central

    Madhusudhan, Kumble Seetharama; Gamanagatti, Shivanand; Srivastava, Deep Narayan; Gupta, Arun Kumar

    2016-01-01

    Malignant biliary obstruction is commonly caused by gall bladder carcinoma, cholangiocarcinoma and metastatic nodes. Percutaneous interventions play an important role in managing these patients. Biliary drainage, which forms the major bulk of radiological interventions, can be palliative in inoperable patients or pre-operative to improve liver function prior to surgery. Other interventions include cholecystostomy and radiofrequency ablation. We present here the indications, contraindications, technique and complications of the radiological interventions performed in patients with malignant biliary obstruction. PMID:27247718

  11. Core ethical values of radiological protection applied to Fukushima case: reflecting common morality and cultural diversities.

    PubMed

    Kurihara, Chieko; Cho, Kunwoo; Toohey, Richard E

    2016-12-01

    The International Commission on Radiological Protection (ICRP) has established Task Group 94 (TG94) to develop a publication to clarify the ethical foundations of the radiological protection system it recommends. This TG identified four core ethical values which structure the system: beneficence and non-maleficence, prudence, justice, and dignity. Since the ICRP is an international organization, its recommendations and guidance should be globally applicable and acceptable. Therefore, first this paper presents the basic principles of the ICRP radiological protection system and its core ethical values, along with a reflection on the variation of these values in Western and Eastern cultural traditions. Secondly, this paper reflects upon how these values can be applied in difficult ethical dilemmas as in the case of the emergency and post-accident phases of a nuclear power plant accident, using the Fukushima case to illustrate the challenges at stake. We found that the core ethical values underlying the ICRP system of radiological protection seem to be quite common throughout the world, although there are some variations among various cultural contexts. Especially we found that 'prudence' would call for somewhat different implementation in each cultural context, balancing and integrating sometime conflicting values, but always with objectives to achieve the well-being of people, which is itself the ultimate aim of the radiological protection system.

  12. The role of radiology in the Oklahoma City bombing.

    PubMed

    Nye, P J; Tytle, T L; Jarman, R N; Eaton, B G

    1996-08-01

    To evaluate the role of radiologic services in the assessment of injuries and identification of deceased victims of the bombing of the Alfred P. Murrah Federal Building in Oklahoma City, Okla. In cooperation with the Oklahoma University Health Sciences Center Disaster Studies Group, all victims of the Oklahoma City bombing who were treated in hospitals were evaluated. All radiologic studies performed in these patients during a 4-week period after the bombing were recorded. Major injuries incurred by the victims were noted but were not documented. In addition, assistance provided by radiologic services to the medical examiner's office for identification of deceased victims was assessed. On the day of the bombing, 99% (480 of 485) of the imaging studies performed were either plain radiography, primarily of the extremities and chest, or computed tomography (CT), half of which were of the head. Six deceased victims were identified solely by means of characteristics on radiographs. Almost all bombing-related radiologic studies were either plain radiography or CT. Other modalities had only limited roles. In deceased victims, plain radiography aided identification, and in many other victims it allowed localization of materials that were potential pieces of evidence.

  13. Safety and efficacy for new techniques and imaging using new equipment to support European legislation: an EU coordination action.

    PubMed

    Zoetelief, J; Faulkner, K

    2008-01-01

    The past two decades have witnessed a technologically driven revolution in radiology. At the centre of these developments has been the use of computing. These developments have also been driven by the introduction of new detector and imaging devices in radiology and nuclear medicine, as well as the widespread application of computing techniques to enhance and extract information within the images acquired. Further advances have been introduced into digital practice. These technological developments, however, have not been matched by justification and optimisation studies to ensure that these new imaging devices and techniques are as effective as they might be, or performed at the lowest possible dose. The work programme of the SENTINEL Coordination Action was subdivided into eight work packages: functional performance and standards; efficacy and safety in digital radiology, dentistry and nuclear medicine, cardiology, interventional radiology, population screening/sensitive groups; justification, ethics and efficacy; good practice guidance and training; and project management. The intention of the work programme was to underwrite the safety, efficacy and ethical aspects of digital practice as well as to protect and add value to the equipment used in radiology.

  14. Learning on human resources management in the radiology residency program*

    PubMed Central

    de Oliveira, Aparecido Ferreira; Lederman, Henrique Manoel; Batista, Nildo Alves

    2014-01-01

    Objective To investigate the process of learning on human resource management in the radiology residency program at Escola Paulista de Medicina - Universidade Federal de São Paulo, aiming at improving radiologists' education. Materials and Methods Exploratory study with a quantitative and qualitative approach developed with the faculty staff, preceptors and residents of the program, utilizing a Likert questionnaire (46), taped interviews (18), and categorization based on thematic analysis. Results According to 71% of the participants, residents have clarity about their role in the development of their activities, and 48% said that residents have no opportunity to learn how to manage their work in a multidisciplinary team. Conclusion Isolation at medical records room, little interactivity between sectors with diversified and fixed activities, absence of a previous culture and lack of a training program on human resources management may interfere in the development of skills for the residents' practice. There is a need to review objectives of the medical residency in the field of radiology, incorporating, whenever possible, the commitment to the training of skills related to human resources management thus widening the scope of abilities of the future radiologists. PMID:25741056

  15. A practical approach for inexpensive searches of radiology report databases.

    PubMed

    Desjardins, Benoit; Hamilton, R Curtis

    2007-06-01

    We present a method to perform full text searches of radiology reports for the large number of departments that do not have this ability as part of their radiology or hospital information system. A tool written in Microsoft Access (front-end) has been designed to search a server (back-end) containing the indexed backup weekly copy of the full relational database extracted from a radiology information system (RIS). This front end-/back-end approach has been implemented in a large academic radiology department, and is used for teaching, research and administrative purposes. The weekly second backup of the 80 GB, 4 million record RIS database takes 2 hours. Further indexing of the exported radiology reports takes 6 hours. Individual searches of the indexed database typically take less than 1 minute on the indexed database and 30-60 minutes on the nonindexed database. Guidelines to properly address privacy and institutional review board issues are closely followed by all users. This method has potential to improve teaching, research, and administrative programs within radiology departments that cannot afford more expensive technology.

  16. [Comparison of time-oriented cost accounting catalogs to control a department of radiology].

    PubMed

    Hackländer, T; Mertens, H; Cramer, B M

    2005-03-01

    Within a hospital, the radiology department has taken over the role of a cost center. Cost accounting can be applied to analyze the costs for the performance of services. By assigning the expenditures of resources to the service, the cash value can directly be distributed to the costs of equipment, material and rooms. Time-oriented catalogs of services are predefined to calculate the number of the employees for a radiology department. Using our own survey of time data, we examined whether such catalogs correctly represent the time consumed in a radiology department. Only services relevant for the turnover were compared. For 96 primary radiological services defined by the score-oriented German fee catalog for physicians (Gebuhrenordnung fur Arzte), a ranking list was made for the annual procedures in descending frequency order. According to the Pareto principle, the 11 services with the highest frequency were chosen and the time consumed for the technical and medical services was collected over a period of 2 months. This survey was compared with the time-oriented catalogs TARMED and EBM 2000plus. The included 11 relevant radiological services represented 80.3 % of the annual procedures of our radiology department. When comparing the technical services between the time-oriented catalogs and our own survey, TARMED gives a better description of the time consumed in 7 of the 11 services and EMB 2000plus in 3 services. When comparing the medical services, TARMED gives a better description of the time consumed in 6 of the 11 services and EBM 2000plus in 4 services. When averaging all the radiological services, TARMED overestimates the current number of physicians necessary for primary reading by a factor of 10.0 % and EBM 2000plus by a factor of 2.6 %. As to the time spent on performing the relevant radiological services, TARMED is slightly superior to describe the radiology department of a hospital than EBM 2000plus. For calculating the number of physicians necessary for primary reading, EBM 2000plus is superior to TARMED.

  17. Migration of a foreign body into the colon and its autonomous excretion.

    PubMed

    Modrzejewski, Andrzej; Kiciak, Adam; Sledż, Marcin; Sygit, Katarzyna; Borycka-Kiciak, Katarzyna; Grzesiak, Wilhelm; Tarnowski, Wiesław

    2011-02-25

    The frequency of foreign body retention in the abdominal cavity ranges from 1 in 100 to 1 in 3000 surgeries performed. Worldwide literature describes only a few cases of the migration of misplaced surgical gauze into the colon. The first case is a 60-year-old patient following laparoscopic cholecystectomy, who excreted (on his own) a cotton sheet 30 × 65 cm after 26 weeks, which did not possess a radiological locator. The latter fact caused diagnostic difficulties in interpreting ultrasonography, CT-scans and abdominal X-rays. Colonoscopy after 4 months following the excretion of the sheet showed flat, stretched ulceration of the colonic wall near the hepatic turn. The second case is a 76-year-old who had undergone several abdominal surgeries, including a classical cholecystectomy and extirpation of the uterus along with related tissues, as a result of cancer and with subsequent radiotherapy. The reason for the last intervention was an occlusion, which required a resection due to abscesses inside the peritoneal cavity. Abdominal pain continued after the surgery. Uroscopy and abdominal X-rays were performed 3 months later, which confirmed the presence of foreign matter in the abdominal cavity. Most foreign objects that have migrated into the colon will be excreted autonomously, which warrants a conservative assessment. Radiologically-tagged materials should be used, which will greatly ease identification in cases of suspected retention of surgical materials in the abdominal cavity.

  18. 77 FR 39498 - Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-03

    ...] Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection Devices Applied... Clinical Performance Assessment: Considerations for Computer-Assisted Detection Devices Applied to... guidance, entitled ``Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device...

  19. Systematic Viewing in Radiology: Seeing More, Missing Less?

    ERIC Educational Resources Information Center

    Kok, Ellen M.; Jarodzka, Halszka; de Bruin, Anique B. H.; BinAmir, Hussain A. N.; Robben, Simon G. F.; van Merriënboer, Jeroen J. G.

    2016-01-01

    To prevent radiologists from overlooking lesions, radiology textbooks recommend "systematic viewing," a technique whereby anatomical areas are inspected in a fixed order. This would ensure complete inspection (full coverage) of the image and, in turn, improve diagnostic performance. To test this assumption, two experiments were…

  20. The Importance of Curriculum-Based Training and Assessment in Interventional Radiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belli, Anna-Maria, E-mail: anna.belli@stgeorges.nhs.uk; Reekers, Jim A., E-mail: j.a.reekers@amc.uva.nl; Lee, Michael, E-mail: mlee@rcsi.ie

    Physician performance and outcomes are being scrutinised by health care providers to improve patient safety and cost efficiency. Patients are best served by physicians who have undergone appropriate specialist training and assessment and perform large numbers of cases to maintain their skills. The Cardiovascular and Interventional Radiological Society of Europe has put into place a curriculum for training in interventional radiology (IR) and a syllabus with an examination, the European Board of Interventional Radiology, providing evidence of attainment of an appropriate and satisfactory skill set for the safe practice of IR. This curriculum is appropriate for IR where there ismore » a high volume of image-guided procedures in vascular and nonvascular organ systems with cross-use of minimally invasive techniques in patients with a variety of disease processes. Other specialties may require different, longer, and more focused training if their experience is “diluted” by the need to master a different skill set.« less

  1. Interventional therapeutic procedures in the musculoskeletal system: an Italian Survey by the Italian College of Musculoskeletal Radiology.

    PubMed

    Silvestri, Enzo; Barile, Antonio; Albano, Domenico; Messina, Carmelo; Orlandi, Davide; Corazza, Angelo; Zugaro, Luigi; Masciocchi, Carlo; Sconfienza, Luca Maria

    2018-04-01

    To perform an online survey among all members of the Italian College of Musculoskeletal Radiology to understand how therapeutic musculoskeletal procedures are performed in daily practice in Italy. We administered an online survey to all 2405 members about the use of therapeutic musculoskeletal procedures in their institutions asking 16 different questions. Subgroup analysis was performed between general and orthopaedic hospitals with Mann-Whitney U and χ 2 statistics. A total of 129/2405 answers (5.4% of members) were included in our analysis. A median of 142.5 (25th-75th percentiles: 50-535.5; range 10-5000) therapeutic musculoskeletal procedures per single institution was performed in 2016. Arthropathic pain was the main indication. The most common procedures were joint injection, bursal/tendon injection, and irrigation of calcific tendinopathy. Ultrasound-guided procedures were mainly performed in ultrasonography rooms (77.4%) rather than in dedicated interventional rooms (22.6%). Conversely, fluoroscopic procedures were performed almost with the same frequency in interventional radiology suites (52.4%) and in general radiology rooms (47.6%). In most institutions (72%), autologous blood or components were not used. The median number of therapeutic musculoskeletal procedures performed in orthopaedic hospitals was significantly higher than in general hospitals (P = 0.002), as well as for the use of autologous preparations (P = 0.004). Joint injection, bursal/tendon injection, and irrigation of calcific tendinopathy were the most common therapeutic musculoskeletal procedures, being arthropathic pain the main indication. The percentage of procedures and the use of autologous preparations were significantly higher in orthopaedic hospitals than in general hospitals.

  2. Penetrating skull fracture by a wooden object: Management dilemmas and literature review

    PubMed Central

    Arifin, Muhammad Zafrullah; Gill, Arwinder Singh; Faried, Ahmad

    2012-01-01

    Most penetrating skull injuries are caused by gun shot wounds or missiles. The compound depressed skull fracture represents an acute neurosurgical emergency. Management and diagnosis of such cases have been described, but its occurence following a fall onto a piece of wood is quite unusual. A 75-year-old female fell onto a piece of wood that penetrated her skull on the left frontal region and was treated in our department. The patient had no neurological deficits during presentation. She was managed surgically and removal of the wooden object was performed to prevent early or late infection complications. Wooden foreign bodies often pose a different set of challenges as far as penetrating injuries to the brain are concerned. Radiological difficulties and increased rates of infection due to its porous nature make these types of injuries particularly interesting. Their early diagnosis and appropriate treatment can minimize the risk of complications. PMID:23293668

  3. Anesthesia Practice and Clinical Trends in Interventional Radiology: A European Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haslam, Philip J.; Yap, Bernard; Mueller, Peter R.

    Purpose: To determine current European practice in interventional radiology regarding nursing care, anesthesia, and clinical care trends.Methods: A survey was sent to 977 European interventional radiologists to assess the use of sedoanalgesia, nursing care, monitoring equipment, pre- and postprocedural care, and clinical trends in interventional radiology. Patterns of sedoanalgesia were recorded for both vascular and visceral interventional procedures. Responders rated their preferred level of sedoanalgesia for each procedure as follows: (a) awake/alert, (b) drowsy/arousable, (c) asleep/arousable, (d) deep sedation, and (e) general anesthesia. Sedoanalgesic drugs and patient care trends were also recorded. A comparison was performed with data derived frommore » a similar survey of interventional practice in the United States.Results: Two hundred and forty-three of 977 radiologists responded (25%). The total number of procedures analyzed was 210,194. The majority (56%) of diagnostic and therapeutic vascular procedures were performed at the awake/alert level of sedation, 32% were performed at the drowsy/arousable level, and 12% at deeper levels of sedation. The majority of visceral interventional procedures were performed at the drowsy/arousable level of sedation (41%), 29% were performed at deeper levels of sedation, and 30% at the awake/alert level. In general, more sedoanalgesia is used in the United States. Eighty-three percent of respondents reported the use of a full-time radiology nurse, 67% used routine blood pressure/pulse oximetry monitoring, and 46% reported the presence of a dedicated recovery area. Forty-nine percent reported daily patient rounds, 30% had inpatient hospital beds, and 51% had day case beds.Conclusion: This survey shows clear differences in the use of sedation for vascular and visceral interventional procedures. Many, often complex, procedures are performed at the awake/alert level of sedation in Europe, whereas deeper levels of sedation are used in the United States. Trends toward making interventional radiology a clinical specialty are evident, with 51% of respondents having day case beds, and 30% having inpatient beds.« less

  4. Performance of a Machine Learning Classifier of Knee MRI Reports in Two Large Academic Radiology Practices: A Tool to Estimate Diagnostic Yield.

    PubMed

    Hassanpour, Saeed; Langlotz, Curtis P; Amrhein, Timothy J; Befera, Nicholas T; Lungren, Matthew P

    2017-04-01

    The purpose of this study is to evaluate the performance of a natural language processing (NLP) system in classifying a database of free-text knee MRI reports at two separate academic radiology practices. An NLP system that uses terms and patterns in manually classified narrative knee MRI reports was constructed. The NLP system was trained and tested on expert-classified knee MRI reports from two major health care organizations. Radiology reports were modeled in the training set as vectors, and a support vector machine framework was used to train the classifier. A separate test set from each organization was used to evaluate the performance of the system. We evaluated the performance of the system both within and across organizations. Standard evaluation metrics, such as accuracy, precision, recall, and F1 score (i.e., the weighted average of the precision and recall), and their respective 95% CIs were used to measure the efficacy of our classification system. The accuracy for radiology reports that belonged to the model's clinically significant concept classes after training data from the same institution was good, yielding an F1 score greater than 90% (95% CI, 84.6-97.3%). Performance of the classifier on cross-institutional application without institution-specific training data yielded F1 scores of 77.6% (95% CI, 69.5-85.7%) and 90.2% (95% CI, 84.5-95.9%) at the two organizations studied. The results show excellent accuracy by the NLP machine learning classifier in classifying free-text knee MRI reports, supporting the institution-independent reproducibility of knee MRI report classification. Furthermore, the machine learning classifier performed well on free-text knee MRI reports from another institution. These data support the feasibility of multiinstitutional classification of radiologic imaging text reports with a single machine learning classifier without requiring institution-specific training data.

  5. Update on the diagnostic radiologist employment market: findings through 2004.

    PubMed

    Saket, Daniel D; Nwanze, Chukwuemeka C; Maynard, C Douglas; Sunshine, Jonathan H; Forman, Howard P

    2005-12-01

    The objective of this article is to summarize the latest information concerning the diagnostic radiologist employment market. Three sources of data are presented and compared with previous data: vacancies in academic radiology departments as of July; the ratio of job listings to job seekers at a major placement service; and the number of positions advertised in Radiology and the American Journal of Roentgenology. Vacancies in academic radiology departments averaged 3.9 in 2004, down 29%, and decreased for all subspecialties as compared with 2001, but the number of vacancies remained very similar to that for 2003. Job listings per job seeker were 1.1 in 2004, stable over the past 2 years but at the lowest level since 1997. The overall number of positions advertised declined by 14% in 2003 compared with 2002 and by an additional 17% in 2004, reaching the lowest level since 1998. In 2004, 45.3% of positions advertised were academic. Comparing 2003-2004 with 2001-2002, all geographic regions exhibited absolute declines in advertisements except the Northeast, which showed a 1.5% increase. Absolute increases occurred for musculoskeletal and emergency radiology positions. Statistically significant proportional decreases occurred for general radiology, vascular/interventional radiology, and pediatric radiology. Three separate data sources confirm a substantial and broad-based multiyear decline in the strength of the demand for diagnostic radiologists, with some shifting in relative demand for subspecialties. It is not clear if the decrease continued in 2004 or if 2004 demand was similar to that of 2003. Data are relative and do not indicate the employment market is weak in absolute terms.

  6. Value of dual-energy CT enterography in the analysis of pathological bowel segments in patients with Crohn's disease.

    PubMed

    Villanueva Campos, A M; Tardáguila de la Fuente, G; Utrera Pérez, E; Jurado Basildo, C; Mera Fernández, D; Martínez Rodríguez, C

    To analyze whether there are significant differences in the objective quantitative parameters obtained in the postprocessing of dual-energy CT enterography studies between bowel segments with radiologic signs of Crohn's disease and radiologically normal segments. This retrospective study analyzed 33 patients (16 men and 17 women; mean age 54 years) with known Crohn's disease who underwent CT enterography on a dual-energy scanner with oral sorbitol and intravenous contrast material in the portal phase. Images obtained with dual energy were postprocessed to obtain color maps (iodine maps). For each patient, regions of interest were traced on these color maps and the density of iodine (mg/ml) and the fat fraction (%) were calculated for the wall of a pathologic bowel segment with radiologic signs of Crohn's disease and for the wall of a healthy bowel segment; the differences in these parameters between the two segments were analyzed. The density of iodine was lower in the radiologically normal segments than in the pathologic segments [1.8 ± 0.4mg/ml vs. 3.7 ± 0.9mg/ml; p<0.05]. The fat fraction was higher in the radiologically normal segments than in the pathologic segments [32.42% ± 6.5 vs. 22.23% ± 9.4; p<0.05]. There are significant differences in the iodine density and fat fraction between bowel segments with radiologic signs of Crohn's disease and radiologically normal segments. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Pediatric Interventional Radiology: Vascular Interventions.

    PubMed

    Kandasamy, Devasenathipathy; Gamanagatti, Shivanand; Gupta, Arun Kumar

    2016-07-01

    Pediatric interventional radiology (PIR) comprises a range of minimally invasive diagnostic and therapeutic procedures that are performed using image guidance. PIR has emerged as an essential adjunct to various surgical and medical conditions. Over the years, technology has undergone dramatic and continuous evolution, making this speciality grow. In this review, the authors will discuss various vascular interventional procedures undertaken in pediatric patients. It is challenging for the interventional radiologist to accomplish a successful interventional procedure. There are many vascular interventional radiology procedures which are being performed and have changed the way the diseases are managed. Some of the procedures are life saving and have become the treatment of choice in those patients. The future is indeed bright for the practice and practitioners of pediatric vascular and non-vascular interventions. As more and more of the procedures that are currently being performed in adults get gradually adapted for use in the pediatric population, it may be possible to perform safe and successful interventions in many of the pediatric vascular lesions that are otherwise being referred for surgery.

  8. Results of the independent verification of radiological remedial action at 600 South Clayhill Drive (AKA 600 South Cemetery Road), Monticello, Utah (MS00145)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, M.J.; Crutcher, J.W.

    1991-07-01

    In 1980 the site of a vanadium and uranium mill at Monticello, Utah, was accepted into the US Department of Energy's (DOE's) Surplus Facilities Management Program, with the objectives of restoring the government-owned mill site to safe levels of radioactivity, disposing of or containing the tailings in an environmentally safe manner, and performing remedial actions on off-site (vicinity) properties that had been contaminated by radioactive material resulting from mill operations. During 1986 and 1987, UNC Geotech, the remedial action contractor designated by DOE, performed remedial action on the vicinity property at 600 South Cemetery Road (updated by San Juan Countymore » and the state of Utah to 600 South Clayhill Drive), Monticello, Utah. The Pollutant Assessments Group (PAG) of Oak Ridge National Laboratory was assigned the responsibility of verifying the data supporting the adequacy of remedial action and confirming the site's compliance with DOE guidelines. The PAG found that the site successfully meets the DOE remedial action objectives. Procedures used by PAG are described. 3 refs., 2 tabs.« less

  9. An easy and effective approach to manage radiologic portable document format (PDF) files using iTunes.

    PubMed

    Qian, Li Jun; Zhou, Mi; Xu, Jian Rong

    2008-07-01

    The objective of this article is to explain an easy and effective approach for managing radiologic files in portable document format (PDF) using iTunes. PDF files are widely used as a standard file format for electronic publications as well as for medical online documents. Unfortunately, there is a lack of powerful software to manage numerous PDF documents. In this article, we explain how to use the hidden function of iTunes (Apple Computer) to manage PDF documents as easily as managing music files.

  10. The social media revolution.

    PubMed

    Dubose, Cheryl

    2011-01-01

    The growing popularity and use of social media tools such as Facebook, YouTube, Twitter, blogging, and wikis have led to a social media revolution. Given this widespread influence, it is important for educators, administrators, and technologists to understand the risks of using social media in the classroom and workplace. To investigate popular social media sites and their effect on radiologic technology education and business practices. A comprehensive search of literature was performed to examine social media and its applications in education, health care, and business. Social media use is on the rise, affecting all aspects of mainstream society. Leaders in the radiologic sciences should be familiar with social media and cognizant of its risks. Future studies regarding social media use in the radiologic sciences are necessary to determine its effect on the radiologic science community. ©2011 by the American Society of Radiologic Technologists.

  11. Controversy in urinary tract infection management in children: a review of new data and subsequent changes in guidelines.

    PubMed

    Kari, Jameela Abdulaziz; Tullus, Kjell

    2013-12-01

    Controversy and lack of consensus have been encountered in the management of pediatric urinary tract infection (UTI), including its diagnosis, radiological investigations and the use of antibiotic therapy. In this review, we discuss the need for radiological investigations and the extent of their use as well as the need for prophylactic antibiotics in children with UTI and vesicoureteral reflux. Only a small proportion of children with first UTI and no history of antenatal renal abnormalities have clinically important malformations. Renal ultrasound should be performed in febrile infants and young children with UTI; a micturating cystourethrogram should not be performed routinely after the first febrile UTI. Long-term antibiotics appear to reduce the risk of recurrent symptomatic UTI in susceptible children, although the clinical benefit is marginal. Current recommendations encourage performing radiological investigations only in children at risk and discourage routine prophylactic antibiotic use.

  12. Role of conventional radiology and MRi defecography of pelvic floor hernias

    PubMed Central

    2013-01-01

    Background Purpose of the study is to define the role of conventional radiology and MRI in the evaluation of pelvic floor hernias in female pelvic floor disorders. Methods A MEDLINE and PubMed search was performed for journals before March 2013 with MeSH major terms 'MR Defecography' and 'pelvic floor hernias'. Results The prevalence of pelvic floor hernias at conventional radiology was higher if compared with that at MRI. Concerning the hernia content, there were significantly more enteroceles and sigmoidoceles on conventional radiology than on MRI, whereas, in relation to the hernia development modalities, the prevalence of elytroceles, edroceles, and Douglas' hernias at conventional radiology was significantly higher than that at MRI. Conclusions MRI shows lower sensitivity than conventional radiology in the detection of pelvic floor hernias development. The less-invasive MRI may have a role in a better evaluation of the entire pelvic anatomy and pelvic organ interaction especially in patients with multicompartmental defects, planned for surgery. PMID:24267789

  13. Cost accounting of radiological examinations. Cost analysis of radiological examinations of intermediate referral hospitals and general practice.

    PubMed

    Lääperi, A L

    1996-01-01

    The purpose of this study was to analyse the cost structure of radiological procedures in the intermediary referral hospitals and general practice and to develop a cost accounting system for radiological examinations that takes into consideration all relevant cost factors and is suitable for management of radiology departments and regional planning of radiological resources. The material comprised 174,560 basic radiological examinations performed in 1991 at 5 intermediate referral hospitals and 13 public health centres in the Pirkanmaa Hospital District in Finland. All radiological departments in the hospitals were managed by a specialist in radiology. The radiology departments at the public health care centres operated on a self-referral basis by general practitioners. The data were extracted from examination lists, inventories and balance sheets; parts of the data were estimated or calculated. The radiological examinations were compiled according to the type of examination and equipment used: conventional, contrast medium, ultrasound, mammography and roentgen examinations with mobile equipment. The majority of the examinations (87%) comprised conventional radiography. For cost analysis the cost items were grouped into 5 cost factors: personnel, equipment, material, real estate and administration costs. The depreciation time used was 10 years for roentgen equipment, 5 years for ultrasound equipment and 5 to 10 years for other capital goods. An annual interest rate of 10% was applied. Standard average values based on a sample at 2 hospitals were used for the examination-specific radiologist time, radiographer time and material costs. Four cost accounting versions with varying allocation of the major cost items were designed. Two-way analysis of variance of the effect of different allocation methods on the costs and cost structure of the examination groups was performed. On the basis of the cost analysis a cost accounting program containing both monetary and nonmonetary variables was developed. In it the radiologist, radiographer and examination-specific equipment costs were allocated to the examinations applying estimated cost equivalents. Some minor cost items were replaced by a general cost factor (GCF). The program is suitable for internal cost accounting of radiological departments as well as regional planning. If more accurate cost information is required, cost assignment employing the actual consumption of the resources and applying the principles of activity-based cost accounting is recommended. As an application of the cost accounting formula the average costs of the radiological examinations were calculated. In conventional radiography the average proportion of the cost factors in the total material was: personnel costs 43%, equipment costs 26%, material costs 7%, real estate costs 11%, administration and overheads 14%. The average total costs including radiologist costs in the hospitals were (FIM): conventional roentgen examinations 188, contrast medium examinations 695, ultrasound 296, mammography 315, roentgen examinations with mobile equipment 1578. The average total costs without radiologist costs in the public health centres were (FIM): conventional roentgen examinations 107, contrast medium examinations 988, ultrasound 203, mammography 557. The average currency rate of exchange in 1991 was USD 1 = FIM 4.046. The following formula is proposed for calculating the cost of a radiological examination (or a group of examinations) performed with a certain piece of equipment during a period of time (e.g. 1 year): a2/ sigma ax*ax+ b2/ sigma bx*bx+ d1/d5*dx+ e1 + [(c1+ c2) + d4 + (e2 - e3) + f5 + g1+ g2+ i]/n.

  14. Pediatric interventional radiology workforce survey: 10-year follow-up.

    PubMed

    Kaufman, Claire S; James, Charles A; Harned, Roger K; Connolly, Bairbre L; Roebuck, Derek J; Cahill, Anne M; Dubois, Josee; Morello, Frank P; Morgan, Robin K; Sidhu, Manrita K

    2017-05-01

    Pediatric interventional radiology is a distinct subspecialty differing from both pediatric diagnostic radiology and adult interventional radiology. We conducted a workforce survey in 2005 to evaluate the state of pediatric interventional radiology at that time. Since then there have been many advancements to the subspecialty, including the founding of the Society for Pediatric Interventional Radiology (SPIR). To evaluate the current state of the pediatric interventional radiology workforce and compare findings with those of the initial 2005 workforce survey. We sent a two-part survey electronically to members of SPIR, the Society for Pediatric Radiology (SPR), the Society of Chairmen of Radiology in Children's Hospitals (SCORCH) and the Society of Interventional Radiology (SIR). Part 1 focused on individual practitioners (n=177), while part 2 focused on group practices and was answered by a leader from each group (n=88). We examined descriptive statistics and, when possible, compared the results to the study from 2005. A total of 177 individuals replied (a 331% increase over the first study) and 88 pediatric interventional radiology (IR) service sites responded (a 131.6% increase). Pediatric IR has become a more clinically oriented specialty, with a statistically significant increase in services with admitting privileges, clinics and performance of daily rounds. Pediatric IR remains diverse in training and practice. Many challenges still exist, including anesthesia/hospital support, and the unknown impact of the new IR residency on pediatric IR training, although the workforce shortage has been somewhat alleviated, as demonstrated by the decreased mean call from 165 days/year to 67.2 days/year. Pediatric interventional radiology practitioners and services have grown significantly since 2005, although the profile of this small subspecialty has changed and some challenges remain.

  15. The Importance of Human-Computer Interaction in Radiology E-learning.

    PubMed

    den Harder, Annemarie M; Frijlingh, Marissa; Ravesloot, Cécile J; Oosterbaan, Anne E; van der Gijp, Anouk

    2016-04-01

    With the development of cross-sectional imaging techniques and transformation to digital reading of radiological imaging, e-learning might be a promising tool in undergraduate radiology education. In this systematic review of the literature, we evaluate the emergence of image interaction possibilities in radiology e-learning programs and evidence for effects of radiology e-learning on learning outcomes and perspectives of medical students and teachers. A systematic search in PubMed, EMBASE, Cochrane, ERIC, and PsycInfo was performed. Articles were screened by two authors and included when they concerned the evaluation of radiological e-learning tools for undergraduate medical students. Nineteen articles were included. Seven studies evaluated e-learning programs with image interaction possibilities. Students perceived e-learning with image interaction possibilities to be a useful addition to learning with hard copy images and to be effective for learning 3D anatomy. Both e-learning programs with and without image interaction possibilities were found to improve radiological knowledge and skills. In general, students found e-learning programs easy to use, rated image quality high, and found the difficulty level of the courses appropriate. Furthermore, they felt that their knowledge and understanding of radiology improved by using e-learning. In conclusion, the addition of radiology e-learning in undergraduate medical education can improve radiological knowledge and image interpretation skills. Differences between the effect of e-learning with and without image interpretation possibilities on learning outcomes are unknown and should be subject to future research.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muder, R.R.; Reddy, S.C.; Yu, V.L.

    Using an objective scoring system, chest radiographs were reviewed in 23 cases of pneumonia due to the Pittsburgh pneumonia agent (PPA, Tatlockia micdadei, Legionella micdadei), including six cases of pneumonia with simultaneous isolation of PPA and L pneumophila (Legionnaires' disease). Infiltrates were typically segmental to lobar; nodular infiltrates were noted in three cases. Spread to additional lobes after presentation occurred in four of 17 PPA infections. Pneumonia caused by both PPA and L pneumophila was unusually severe, with involvement of all lobes occurring in four of six cases, compared with one of 17 cases of PPA infection (p>0.02). Radiographic severitymore » did not correlate with underlying disease, immune status, or outcome. The majority of patients receiving erythromycin demonstrated objective radiologic improvement. In a patients, population that included nonimmunosuppressed patient, nodule formation and rapid radiologic progression were not found to be characteristic of PPA pneumonia.« less

  17. Scenarios for the Hanford immobilized Low-Activity waste (ILAW) performance assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MANN, F.M.

    The purpose of the next version of the Hanford Immobilized Low-Activity Tank Waste (ILAW) Performance Assessment (ILAW PA) is to provide an updated estimate of the long-term human health and environmental impact of the disposal of ILAW and to compare these estimates against performance objectives displayed in Tables 1,2, and 3 (Mann 1999a). Such a radiological performance assessment is required by U.S. Department of Energy (DOE) Orders on radioactive waste management (DOE 1988a and DOE 1999a). This document defines the scenarios that will be used for the next update of the PA that is scheduled to be issued in 2001.more » Since the previous performance assessment (Mann 1998) was issued, considerable additional data on waste form behavior and site-specific soil geotechnical properties have been collected. In addition, the 2001 ILAW PA will benefit from improved computer models and the experience gained from the previous performance assessment. However, the scenarios (that is, the features, events, and processes analyzed in the Performance assessment) for the next PA are very similar to the ones in the 1998 PA.« less

  18. Development and initial evaluation of a training program for peripherally inserted central catheter (PICC) placement for radiology residents and technicians.

    PubMed

    Dabadie, A; Soussan, J; Mancini, J; Vidal, V; Bartoli, J M; Gorincour, G; Petit, P

    2016-09-01

    The goals of this study were to develop and evaluate a joint theoretical/practical training course for radiology residents and technicians and to start a collaborative practice agreement enabling radiology technicians to perform PICC placement under the responsibility of an interventional radiologist. A joint training session based on literature evidences and international recommendations was designed. Participants were assessed before and after training, and were also asked to evaluate the program one month after completion of the training course. Practical post-training mentoring guidelines were laid down for radiologists supervising technicians. From January to April 2014, 6 radiology residents and 12 radiology technicians from the two interventional radiology departments of the University hospitals in Marseille took part in the training program. For both residents and technicians, significant improvement was observed between pretraining and post-training assessment. The majority of participants were satisfied with the program. Our experience suggests that combined theoretical and practical training in PICC placement allows improving technical skill and yields high degrees of satisfaction for both radiology residents and technicians. A collaborative practice agreement is now formally established to enable radiologists to delegate PICC placement procedures to radiology technicians. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  19. Activity-based costing in radiology. Application in a pediatric radiological unit.

    PubMed

    Laurila, J; Suramo, I; Brommels, M; Tolppanen, E M; Koivukangas, P; Lanning, P; Standertskjöld-Nordenstam, G

    2000-03-01

    To get an informative and detailed picture of the resource utilization in a radiology department in order to support its pricing and management. A system based mainly on the theoretical foundations of activity-based costing (ABC) was designed, tested and compared with conventional costing. The study was performed at the Pediatric Unit of the Department of Radiology, Oulu University Hospital. The material consisted of all the 7,452 radiological procedures done in the unit during the first half of 1994, when both methods of costing where in use. Detailed cost data were obtained from the hospital financial and personnel systems and then related to activity data captured in the radiology information system. The allocation of overhead costs was greatly reduced by the introduction of ABC compared to conventional costing. The overhead cost as a percentage of total costs dropped to one-fourth of total costs, from 57% to 16%. The change of unit costs of radiological procedures varied from -42% to +82%. Costing is much more detailed and precise, and the percentage of unspecified allocated overhead costs diminishes drastically when ABC is used. The new information enhances effective departmental management, as the whole process of radiological procedures is identifiable by single activities, amenable to corrective actions and process improvement.

  20. Use of Low-Fidelity Simulation Laboratory Training for Teaching Radiology Residents CT-Guided Procedures.

    PubMed

    Picard, Melissa; Nelson, Rachel; Roebel, John; Collins, Heather; Anderson, M Bret

    2016-11-01

    To determine the benefit of the addition of low-fidelity simulation-based training to the standard didactic-based training in teaching radiology residents common CT-guided procedures. This was a prospective study involving 24 radiology residents across all years in a university program. All residents underwent standard didactic lecture followed by low-fidelity simulation-based training on three common CT-guided procedures: random liver biopsy, lung nodule biopsy, and drain placement. Baseline knowledge, confidence, and performance assessments were obtained after the didactic session and before the simulation training session. Approximately 2 months later, all residents participated in a simulation-based training session covering all three of these procedures. Knowledge, confidence, and performance data were obtained afterward. These assessments covered topics related to preprocedure workup, intraprocedure steps, and postprocedure management. Knowledge data were collected based on a 15-question assessment. Confidence data were obtained based on a 5-point Likert-like scale. Performance data were obtained based on successful completion of predefined critical steps. There was significant improvement in knowledge (P = .005), confidence (P < .008), and tested performance (P < .043) after the addition of simulation-based training to the standard didactic curriculum for all procedures. This study suggests that the addition of low-fidelity simulation-based training to a standard didactic-based curriculum is beneficial in improving resident knowledge, confidence, and tested performance of common CT-guided procedures. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. Paranasal sinus disease in HIV antibody positive patients.

    PubMed Central

    Grant, A; von Schoenberg, M; Grant, H R; Miller, R F

    1993-01-01

    OBJECTIVE--To investigate the prevalence of radiologically-diagnosed paranasal sinus disease in HIV-1 seropositive patients. SUBJECTS AND SETTING--476 patients admitted to a dedicated inpatient unit for HIV and AIDS at the Middlesex Hospital, London, between September 1988 and February 1992. DESIGN--Retrospective review of patients' case notes and radiological records. RESULTS--30 patients (6.3%) had radiological evidence of paranasal sinus disease. At the time of admission, sinusitis was in the differential diagnosis in only 12 of the 30 patients; 13 patients were initially diagnosed as having meningitis. Pseudomonas aeruginosa was the causative organism in four patients, all of whom had advanced HIV disease. All four responded to appropriate antibiotics but had early relapse of infection. CONCLUSIONS--Sinusitis is an important and under-recognised cause of morbidity in patients with HIV disease. Images PMID:8335314

  2. NTS radiological assessment project: comparison of delta-surface interpolation with kriging for the Frenchman Lake region of area 5

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foley, T.A. Jr.

    The primary objective of this report is to compare the results of delta surface interpolation with kriging on four large sets of radiological data sampled in the Frenchman Lake region at the Nevada Test Site. The results of kriging, described in Barnes, Giacomini, Reiman, and Elliott, are very similar to those using the delta surface interpolant. The other topic studied is in reducing the number of sample points and obtaining results similar to those using all of the data. The positive results here suggest that great savings of time and money can be made. Furthermore, the delta surface interpolant ismore » viewed as a contour map and as a three dimensional surface. These graphical representations help in the analysis of the large sets of radiological data.« less

  3. A Clinical Decision Support System Using Ultrasound Textures and Radiologic Features to Distinguish Metastasis From Tumor-Free Cervical Lymph Nodes in Patients With Papillary Thyroid Carcinoma.

    PubMed

    Abbasian Ardakani, Ali; Reiazi, Reza; Mohammadi, Afshin

    2018-03-30

    This study investigated the potential of a clinical decision support approach for the classification of metastatic and tumor-free cervical lymph nodes (LNs) in papillary thyroid carcinoma on the basis of radiologic and textural analysis through ultrasound (US) imaging. In this research, 170 metastatic and 170 tumor-free LNs were examined by the proposed clinical decision support method. To discover the difference between the groups, US imaging was used for the extraction of radiologic and textural features. The radiologic features in the B-mode scans included the echogenicity, margin, shape, and presence of microcalcification. To extract the textural features, a wavelet transform was applied. A support vector machine classifier was used to classify the LNs. In the training set data, a combination of radiologic and textural features represented the best performance with sensitivity, specificity, accuracy, and area under the curve (AUC) values of 97.14%, 98.57%, 97.86%, and 0.994, respectively, whereas the classification based on radiologic and textural features alone yielded lower performance, with AUCs of 0.964 and 0.922. On testing the data set, the proposed model could classify the tumor-free and metastatic LNs with an AUC of 0.952, which corresponded to sensitivity, specificity, and accuracy of 93.33%, 96.66%, and 95.00%. The clinical decision support method based on textural and radiologic features has the potential to characterize LNs via 2-dimensional US. Therefore, it can be used as a supplementary technique in daily clinical practice to improve radiologists' understanding of conventional US imaging for characterizing LNs. © 2018 by the American Institute of Ultrasound in Medicine.

  4. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... and other diagnostic procedures. 413.122 Section 413.122 Public Health CENTERS FOR MEDICARE & MEDICAID... radiology services and other diagnostic procedures. (a) Basis and purpose. (1) This section implements... services and other diagnostic procedures performed by a hospital on an outpatient basis. (2) For purposes...

  5. 21 CFR 1002.3 - Notification to user of performance and technical data.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... data. 1002.3 Section 1002.3 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) RADIOLOGICAL HEALTH RECORDS AND REPORTS General Provisions § 1002.3 Notification to... Radiological Health, as authorized under delegated authority, may require a manufacturer of a radiation...

  6. The Effectiveness of Hypermedia Instructional Modules for Radiology Residents.

    ERIC Educational Resources Information Center

    Shaw, Steven G.; And Others

    1995-01-01

    Details the development and field testing of hypermedia training materials for teaching radiology residents at the Montreal General Hospital (Canada). Compares results of randomly teaching 24 residents with either hypermedia or traditional classroom methods. Results indicate that residents who learned with hypermedia generally performed as well as…

  7. Professional Acceptance Of Electronic Images In Radiologic Practice

    NASA Astrophysics Data System (ADS)

    Gitlin, Joseph N.; Curtis, David J.; Kerlin, Barbara D.; Olmsted, William W.

    1983-05-01

    During the past four years, a large number of radiographic images have been interpreted in both film and video modes in an effort to determine the utility of digital/analogue systems in general practice. With the cooperation of the Department of Defense, the MITRE Corporation, and several university-based radiology departments, the Public Health Service has participated in laboratory experiments and a teleradiology field trial to meet this objective. During the field trial, 30 radiologists participated in the interpretation of more than 4,000 diagnostic x-ray examinations that were performed at distant clinics, digitized, and transmitted to a medical center for interpretation on video monitors. As part of the evaluation, all of the participating radiologists and the attending physicians at the clinics were queried regarding the teleradiology system, particularly with respect to the diagnostic quality of the electronic images. The original films for each of the 4,000 examinations were read independently, and the findings and impressions from each mode were compared to identify discrepancies. In addition, a sample of 530 cases was reviewed and interpreted by a consensus panel to measure the accuracy of findings and impressions of both film and video readings. The sample has been retained in an automated archive for future study at the National Center of Devices and Radiological Health facilities in Rockville, Maryland. The studies include a comparison of diagnostic findings and impressions from 1024 x 1024 matrices with those obtained from the 512 x 512 format used in the field trial. The archive also provides a database for determining the effect of data compression techniques on diagnostic interpretations and establishing the utility of image processing algorithms. The paper will include an analysis of the final results of the field trial and preliminary findings from the ongoing studies using the archive of cases at the National Center for Devices and Radiological Health. This paper was not available at the time of printing of the Proceedings.

  8. Lund-Mackay and modified Lund-Mackay score for sinus surgery in children with cystic fibrosis.

    PubMed

    Do, Bao Anh; Lands, Larry C; Mascarella, Marco A; Fanous, Amanda; Saint-Martin, Christine; Manoukian, John J; Nguyen, Lily H P

    2015-08-01

    Patients with cystic fibrosis (CF) frequently present with severe sinonasal disease often requiring radiologic imaging and surgical intervention. Few studies have focused on the relationship between radiologic scoring systems and the need for sinus surgery in this population. The objective of this study is to evaluate the Lund-Mackay (LM) and modified Lund-Mackay (m-LM) scoring systems in predicting the need for sinus surgery or revision surgery in patients with CF. We performed a retrospective chart review of CF patients undergoing computed tomography (CT) sinus imaging at a tertiary care pediatric hospital from 1995 to 2008. Patient scans were scored using both the LM and m-LM systems and compared to the rate of sinus surgery or revision surgery. Receiver-operator characteristics curves (ROC) were used to analyze the radiological scoring systems. A total of 41 children with CF were included in the study. The mean LM score for patients undergoing surgery was 17.3 (±3.1) compared to 11.5 (±6.2) for those treated medically (p<0.01). For the m-LM, the mean score of patients undergoing surgery was 20.3 (±3.5) and 13.5 (±7.3) for those medically treated (p<0.01). Using a ROC curve with a threshold score of 13 for the LM, the sensitivity was 89.3% (95% CI of 72-98) and specificity of 69.2% (95% CI of 39-91). At an optimal score of 19, the m-LM system produced a sensitivity of 67.7% (95% CI of 48-84) and specificity of 84.6% (95% CI of 55-98). The modified Lund-Mackay score provides a high specificity while the Lund-Mackay score a high sensitivity for CF patients who required sinus surgery. The combination of both radiologic scoring systems can potentially predict the need for surgery in this population. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Creation and Validation of a Simulator for Neonatal Brain Ultrasonography: A Pilot Study.

    PubMed

    Tsai, Andy; Barnewolt, Carol E; Prahbu, Sanjay P; Yonekura, Reimi; Hosmer, Andrew; Schulz, Noah E; Weinstock, Peter H

    2017-01-01

    Historically, skills training in performing brain ultrasonography has been limited to hours of scanning infants for lack of adequate synthetic models or alternatives. The aim of this study was to create a simulator and determine its utility as an educational tool in teaching the skills that can be used in performing brain ultrasonography on infants. A brain ultrasonography simulator was created using a combination of multi-modality imaging, three-dimensional printing, material and acoustic engineering, and sculpting and molding. Radiology residents participated prior to their pediatric rotation. The study included (1) an initial questionnaire and resident creation of three coronal images using the simulator; (2) brain ultrasonography lecture; (3) hands-on simulator practice; and (4) a follow-up questionnaire and re-creation of the same three coronal images on the simulator. A blinded radiologist scored the quality of the pre- and post-training images using metrics including symmetry of the images and inclusion of predetermined landmarks. Wilcoxon rank-sum test was used to compare pre- and post-training questionnaire rankings and image quality scores. Ten residents participated in the study. Analysis of pre- and post-training rankings showed improvements in technical knowledge and confidence, and reduction in anxiety in performing brain ultrasonography. Objective measures of image quality likewise improved. Mean reported value score for simulator training was high across participants who reported perceived improvements in scanning skills and enjoyment from simulator use, with interest in additional practice on the simulator and recommendations for its use. This pilot study supports the use of a simulator in teaching radiology residents the skills that can be used to perform brain ultrasonography. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  10. NegBio: a high-performance tool for negation and uncertainty detection in radiology reports.

    PubMed

    Peng, Yifan; Wang, Xiaosong; Lu, Le; Bagheri, Mohammadhadi; Summers, Ronald; Lu, Zhiyong

    2018-01-01

    Negative and uncertain medical findings are frequent in radiology reports, but discriminating them from positive findings remains challenging for information extraction. Here, we propose a new algorithm, NegBio, to detect negative and uncertain findings in radiology reports. Unlike previous rule-based methods, NegBio utilizes patterns on universal dependencies to identify the scope of triggers that are indicative of negation or uncertainty. We evaluated NegBio on four datasets, including two public benchmarking corpora of radiology reports, a new radiology corpus that we annotated for this work, and a public corpus of general clinical texts. Evaluation on these datasets demonstrates that NegBio is highly accurate for detecting negative and uncertain findings and compares favorably to a widely-used state-of-the-art system NegEx (an average of 9.5% improvement in precision and 5.1% in F1-score). https://github.com/ncbi-nlp/NegBio.

  11. Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the PNNL Richland Campus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snyder, Sandra F.; Moleta, Donna Grace L.; Meier, Kirsten M.

    This is the second revision of the DQO Supporting Radiological Air Emissions Monitoring for the Pacific Northwest National Laboratory Richland Campus. In January 2017, the PNNL Richland Campus expanded to the north by 0.35 km 2 (85.6 acres). Under the requirements of Washington State Department of Health Radioactive Air Emissions License (RAEL)-005, the PNNL Campus operates and maintains a radiological air monitoring program. This revision documents and evaluates the newly acquired acreage while also removing recreational land at the southwest, and also re-examines all active radioactive emission units on the PNNL Campus. No buildings are located on this new Campusmore » land, which was transferred from the U.S. DOE Hanford Site. Additionally, this revision includes information regarding the background monitoring station PNL-5 in Benton City, Washington, which became active in October 2016. The key purpose of this revision is to determine the adequacy of the existing environmental surveillance stations to monitor radiological air emissions in light of this northern boundary change.« less

  12. A web based Foundations of Radiological Physics for diagnostic radiology residents.

    PubMed

    Blackmon, Kevin N; Huda, Walter; Lewis, Madelene C; Tipnis, Sameer; Mah, Eugene; Frey, Donald G

    2013-03-01

    RATIONALE AND OBJECTS: We describe a new web-based physics course for radiology residents preparing for the Exam of the Future (EOF). A course was developed with a total of 12 web-based modules. Six modules were focused on "imaging" and six on "radiation." A module was subdivided into nine short "nuggets." Traditional lectures were replaced by modules using prerecorded lectures (Tegrity) to a secure website (WebCT). Each module was accompanied by three quizzes, each consisting of ten questions designed to reinforce covered materials. All online modules were accompanied by a noon conference that employed an Audience Response System (Turning Point). Seventeen first-year residents over 2 consecutive years beginning in July 2010 took this new course, and participated in an anonymous online follow-up survey (Survey Monkey). The recorded 12 modules had an overall average duration of 72 ± 19 minutes. Ten of 17 residents expressed a preference of 15 minutes for nugget duration. Highest personal assessment scores of each resident's understanding were obtained in human radiation risks and radiation protection. Residents considered supplemental noon conferences to be important for learning radiological physics. Satisfaction level was largely positive, with five residents highly satisfied, nine residents somewhat satisfied, two residents neutral, and only one resident somewhat dissatisfied. Our Foundations of Radiological Physics course was well received and served as the springboard for mastering x-ray-based imaging modalities of radiography, mammography, fluoroscopy, interventional radiology, and computed tomography. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  13. A Head and Neck Simulator for Radiology and Radiotherapy

    NASA Astrophysics Data System (ADS)

    Thompson, Larissa; Campos, Tarcísio P. R.

    2013-06-01

    Phantoms are suitable tools to simulate body tissues and organs in radiology and radiation therapy. This study presents the development of a physical head and neck phantom and its radiological response for simulating brain pathology. The following features on the phantom are addressed and compared to human data: mass density, chemical composition, anatomical shape, computerized tomography images and Hounsfield Units. Mass attenuation and kerma coefficients of the synthetic phantom and normal tissues, as well as their deviations, were also investigated. Radiological experiments were performed, including brain tumors and subarachnoid hemorrhage simulations. Computerized tomography images of such pathologies in phantom and human were obtained. The anthropometric dimensions of the phantom present anatomical conformation similar to a human head and neck. Elemental weight percentages of the equivalent tissues match the human ones. Hounsfield Unit values of the main developed structures are presented, approaching human data. Kerma and mass attenuation coefficients spectra from human and phantom are presented, demonstrating smaller deviations in the radiological X-ray spectral domain. In conclusion, the phantom presented suitable normal and pathological radiological responses relative to those observed in humans. It may improve radiological protocols and education in medical imaging.

  14. Natural Language Processing in Radiology: A Systematic Review.

    PubMed

    Pons, Ewoud; Braun, Loes M M; Hunink, M G Myriam; Kors, Jan A

    2016-05-01

    Radiological reporting has generated large quantities of digital content within the electronic health record, which is potentially a valuable source of information for improving clinical care and supporting research. Although radiology reports are stored for communication and documentation of diagnostic imaging, harnessing their potential requires efficient and automated information extraction: they exist mainly as free-text clinical narrative, from which it is a major challenge to obtain structured data. Natural language processing (NLP) provides techniques that aid the conversion of text into a structured representation, and thus enables computers to derive meaning from human (ie, natural language) input. Used on radiology reports, NLP techniques enable automatic identification and extraction of information. By exploring the various purposes for their use, this review examines how radiology benefits from NLP. A systematic literature search identified 67 relevant publications describing NLP methods that support practical applications in radiology. This review takes a close look at the individual studies in terms of tasks (ie, the extracted information), the NLP methodology and tools used, and their application purpose and performance results. Additionally, limitations, future challenges, and requirements for advancing NLP in radiology will be discussed. (©) RSNA, 2016 Online supplemental material is available for this article.

  15. Extracting numeric measurements and temporal coordinates from Japanese radiological reports

    NASA Astrophysics Data System (ADS)

    Imai, Takeshi; Onogi, Yuzo

    2004-04-01

    Medical records are written mainly, in natural language. The focus of this study is narrative radiological reports written in natural Japanese. These reports cannot be used for advanced retrieval, data mining, and so on, unless they are stored, using a structured format such as DICOM-SR. The goal is to structure narrative reports progressively, using natural language processing (NLP). Structure has many different levels, for example, DICOM-SR has three established levels -- basic text, enhanced and comprehensive. At the enhanced level, it is necessary to use numerical measurements and spatial & temporal coordinates. In this study, the wording used in the reports was first standardized, dictionaries were organized, and morphological analysis performed. Next, numerical measurements and temporal coordinates were extracted, and the objects to which they referred, analyzed. 10,000 CT and MR reports were separated into 82,122 sentences, and 34,269 of the 36,444 numerical descriptions were tagged. Periods, slashes, hyphens, and parentheses are ambiguously used in the description of enumerated lists, dates, image numbers, and anatomical names, as well as at the end of sentences; to resolve this ambiguity, descriptions were processed, according to the order -- date, size, unit, enumerated list, and abbreviation -- then, the tagged reports were separated into sentences.

  16. Strategic proposal for a national trauma system in France.

    PubMed

    Gauss, Tobias; Balandraud, Paul; Frandon, Julien; Abba, Julio; Ageron, Francois Xavier; Albaladejo, Pierre; Arvieux, Catherine; Barbois, Sandrine; Bijok, Benjamin; Bobbia, Xavier; Charbit, Jonathan; Cook, Fabrice; David, Jean-Stephane; Maurice, Guillaume De Saint; Duranteau, Jacques; Garrigue, Delphine; Gay, Emmanuel; Geeraerts, Thomas; Ghelfi, Julien; Hamada, Sophie; Harrois, Anatole; Kobeiter, Hicham; Leone, Marc; Levrat, Albrice; Mirek, Sebastien; Nadji, Abdel; Paugam-Burtz, Catherine; Payen, Jean Francois; Perbet, Sebastien; Pirracchio, Romain; Plenier, Isabelle; Pottecher, Julien; Rigal, Sylvain; Riou, Bruno; Savary, Dominique; Secheresse, Thierry; Tazarourte, Karim; Thony, Frederic; Tonetti, Jerome; Tresallet, Christophe; Wey, Pierre-Francois; Picard, Julien; Bouzat, Pierre

    2018-05-29

    In this road map for trauma in France, we focus on the main challenges for system implementation, surgical and radiology training, and upon innovative training techniques. Regarding system organisation: procedures for triage, designation and certification of trauma centres are mandatory to implement trauma networks on a national scale. Data collection with registries must be created, with a core dataset defined and applied through all registries. Regarding surgical and radiology training, diagnostic-imaging processes should be standardised and the role of the interventional radiologist within the trauma team and the trauma network should be clearly defined. Education in surgery for trauma is crucial and recent changes in medical training in France will promote trauma surgery as a specific sub-specialty. Innovative training techniques should be implemented and be based on common objectives, scenarios and evaluation, so as to improve individual and team performances. The group formulated 14 proposals that should help to structure and improve major trauma management in France over the next 10 years. Copyright © 2018 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  17. Transperineal ultrasonography in perianal Crohn disease: A valuable imaging modality.

    PubMed

    Wright, Emily K; Novak, Kerri L; Lu, Cathy; Panaccione, Remo; Ghosh, Subrata; Wilson, Stephanie R

    2015-01-01

    Aims of treatment for Crohn disease have moved beyond the resolution of clinical symptoms to objective end points including endoscopic and radiological normality. Regular re-evaluation of disease status to safely, readily and reliably detect the presence of inflammation and complications is paramount. Improvements in sonographic technology over recent years have facilitated a growing enthusiasm among radiologists and gastroenterologists in the use of ultrasound for the assessment of inflammatory bowel disease. Transabdominal intestinal ultrasound is accurate, affordable and safe for the assessment of luminal inflammation and complications in Crohn disease, and can be performed with or without the use of intravenous contrast enhancement. Perianal fistulizing disease is a common, complex and often treatment-refractory complication of Crohn disease, which requires regular radiological monitoring. Endoanal ultrasound is invasive, uncomfortable and yields limited assessment of the perineal region. Although magnetic resonance imaging of the pelvis is established, timely access may be a problem. Transperineal ultrasound has been described in small studies, and is an accurate, painless and cost-effective method for documenting perianal fluid collections, fistulas and sinus tracts. In the present article, the authors review the literature regarding perineal ultrasound for the assessment of perianal Crohn disease and use case examples to illustrate its clinical utility.

  18. Cover design for radioactive and AMD-producing mine waste in the Ronneburg area, eastern Thuringia.

    PubMed

    Gatzweiler, R; Jahn, S; Neubert, G; Paul, M

    2001-01-01

    At the former uranium mining site of Ronneburg, large scale underground and open pit mining for nearly 40 years resulted in a production of about 113,000 tonnes of uranium and about 200 million cubic metres of mine waste. In their present state, these materials cause risks to human health and strong environmental impacts and therefore demand remedial action. The remediation options available are relocation of mine spoil into the open pit and on site remediation by landscaping/contouring, placement of a cover and revegetation. A suitable vegetated cover system combined with a surface water drainage system provides long-term stability against erosion and reduces acid generation thereby meeting the main remediation objectives which are long-term reduction of radiological exposure and contaminant emissions and recultivation. The design of the cover system includes the evaluation of geotechnical, radiological, hydrological, geochemical and ecological criteria and models. The optimized overall model for the cover system has to comply with general conditions as, e.g. economic efficiency, public acceptance and sustainability. Most critical elements for the long-term performance of the cover system designed for the Beerwalde dump are the barrier system and its long-term integrity and a largely self-sustainable vegetation.

  19. Minimizing Barriers in Learning for On-Call Radiology Residents-End-to-End Web-Based Resident Feedback System.

    PubMed

    Choi, Hailey H; Clark, Jennifer; Jay, Ann K; Filice, Ross W

    2018-02-01

    Feedback is an essential part of medical training, where trainees are provided with information regarding their performance and further directions for improvement. In diagnostic radiology, feedback entails a detailed review of the differences between the residents' preliminary interpretation and the attendings' final interpretation of imaging studies. While the on-call experience of independently interpreting complex cases is important to resident education, the more traditional synchronous "read-out" or joint review is impossible due to multiple constraints. Without an efficient method to compare reports, grade discrepancies, convey salient teaching points, and view images, valuable lessons in image interpretation and report construction are lost. We developed a streamlined web-based system, including report comparison and image viewing, to minimize barriers in asynchronous communication between attending radiologists and on-call residents. Our system provides real-time, end-to-end delivery of case-specific and user-specific feedback in a streamlined, easy-to-view format. We assessed quality improvement subjectively through surveys and objectively through participation metrics. Our web-based feedback system improved user satisfaction for both attending and resident radiologists, and increased attending participation, particularly with regards to cases where substantive discrepancies were identified.

  20. Frequency of Magnetic Resonance Imaging patterns of tuberculous spondylitis in a public sector hospital

    PubMed Central

    Tabassum, Sumera; Haider, Shahbaz

    2016-01-01

    Objective: To determine frequencies of different MRI patterns of tuberculous spondylitisin a public sector hospital in Karachi. Methods: This descriptive multidisciplinary case series study was done from October 25, 2011 to May 28, 2012 in Radiology Department and Department of Medicine in the Jinnah Postgraduate Medical Center Karachi. MRI scans (dorsal / lumbosacral spine) of the Patients presenting with backache in Medical OPD, were performed in Radiology Department. Axial and sagittal images of T1 weighted, T2 weighted and STIR sequences of the affected region were taken. A total of 140 patients who were diagnosed as having tuberculous spondylitis were further evaluated and analyzed for having different patterns of involvement of the spine and compared with similar studies. Results: Among frequencies of different MRI pattern of tuberculous spondylitis, contiguous vertebral involvement was 100%, discal involvement 98.6%, paravertebral abscess 92.1% cases, epidural abscess 91.4%, spinal cord / thecal sac compression 89.3%, vertebral collapse 72.9%, gibbus deformity 42.9% and psoas abscess 36.4%. Conclusion: Contiguous vertebral involvement was commonest MRI pattern, followed by disk involvement, paravertebral & epidural abscesses, thecal sac compression and vertebral collapse. PMID:27022369

  1. Computerized quantitative evaluation of mammographic accreditation phantom images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Yongbum; Tsai, Du-Yih; Shinohara, Norimitsu

    2010-12-15

    Purpose: The objective was to develop and investigate an automated scoring scheme of the American College of Radiology (ACR) mammographic accreditation phantom (RMI 156, Middleton, WI) images. Methods: The developed method consisted of background subtraction, determination of region of interest, classification of fiber and mass objects by Mahalanobis distance, detection of specks by template matching, and rule-based scoring. Fifty-one phantom images were collected from 51 facilities for this study (one facility provided one image). A medical physicist and two radiologic technologists also scored the images. The human and computerized scores were compared. Results: In terms of meeting the ACR's criteria,more » the accuracies of the developed method for computerized evaluation of fiber, mass, and speck were 90%, 80%, and 98%, respectively. Contingency table analysis revealed significant association between observer and computer scores for microcalcifications (p<5%) but not for masses and fibers. Conclusions: The developed method may achieve a stable assessment of visibility for test objects in mammographic accreditation phantom image in whether the phantom image meets the ACR's criteria in the evaluation test, although there is room left for improvement in the approach for fiber and mass objects.« less

  2. Is fusion necessary for thoracolumbar burst fracture treated with spinal fixation? A systematic review and meta-analysis.

    PubMed

    Diniz, Juliete M; Botelho, Ricardo V

    2017-11-01

    OBJECTIVE Thoracolumbar fractures account for 90% of spinal fractures, with the burst subtype corresponding to 20% of this total. Controversy regarding the best treatment for this condition remains. The traditional surgical approach, when indicated, involves spinal fixation and arthrodesis. Newer studies have brought the need for fusion associated with internal fixation into question. Not performing arthrodesis could reduce surgical time and intraoperative bleeding without affecting clinical and radiological outcomes. With this study, the authors aimed to assess the effect of fusion, adjuvant to internal fixation, on surgically treated thoracolumbar burst fractures. METHODS A search of the Medline and Cochrane Central Register of Controlled Trials databases was performed to identify randomized trials that compared the use and nonuse of arthrodesis in association with internal fixation for the treatment of thoracolumbar burst fractures. The search encompassed all data in these databases up to February 28, 2016. RESULTS Five randomized/quasi-randomized trials, which involved a total of 220 patients and an average follow-up time of 69.1 months, were included in this review. No significant difference between groups in the final scores of the visual analog pain scale or Low Back Outcome Scale was detected. Surgical time and blood loss were significantly lower in the group of patients who did not undergo fusion (p < 0.05). Among the evaluated radiological outcomes, greater mobility in the affected segment was found in the group of those who did not undergo fusion. No significant difference between groups in the degree of kyphosis correction, loss of kyphosis correction, or final angle of kyphosis was observed. CONCLUSIONS The data reviewed in this study suggest that the use of arthrodesis did not improve clinical outcomes, but it was associated with increased surgical time and higher intraoperative bleeding and did not promote significant improvement in radiological parameters.

  3. Enhancing Public Access to Relevant and Valued Medical Information: Fresh Directions for RadiologyInfo.org.

    PubMed

    Rubin, Geoffrey D; Krishnaraj, Arun; Mahesh, Mahadevappa; Rajendran, Ramji R; Fishman, Elliot K

    2017-05-01

    RadiologyInfo.org is a public information portal designed to support patient care and broaden public awareness of the essential role radiology plays in overall patient health care. Over the past 14 years, RadiologyInfo.org has evolved considerably to provide access to more than 220 mixed-media descriptions of tests, treatments, and diseases through a spectrum of mobile and desktop platforms, social media, and downloadable documents in both English and Spanish. In 2014, the RSNA-ACR Public Information Website Committee, which stewards RadiologyInfo.org, developed 3- to 5-year strategic and implementation plans for the website. The process was informed by RadiologyInfo.org user surveys, formal stakeholder interviews, focus groups, and usability testing. Metrics were established as key performance indicators to assess progress toward the stated goals of (1) optimizing content to enhance patient-centeredness, (2) enhancing reach and engagement, and (3) maintaining sustainability. Major changes resulting from this process include a complete redesign of the website, the replacement of text-rich PowerPoint presentations with conversational videos, and the development of an affiliate network. Over the past year, visits to RadiologyInfo.org have increased by 60.27% to 1,424,523 in August 2016 from 235 countries and territories. Twenty-two organizations have affiliated with RadiologyInfo.org with new organizations being added on a monthly basis. RadiologyInfo provides a tangible demonstration of how radiologists can engage directly with the global public to educate them on the value of radiology in their health care and to allay concerns and dispel misconceptions. Regular self-assessment and responsive planning will ensure its continued growth and relevance. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  4. Weld Repair of a Stamped Pressure Vessel in a Radiologically Controlled Zone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cannell, Gary L.; Huth, Ralph J.; Hallum, Randall T.

    2013-08-26

    In September 2012 an ASME B&PVC Section VIII stamped pressure vessel located at the DOE Hanford Site Effluent Treatment Facility (ETF) developed a through-wall leak. The vessel, a steam/brine heat exchanger, operated in a radiologically controlled zone (by the CH2MHill PRC or CHPRC), had been in service for approximately 17 years. The heat exchanger is part of a single train evaporator process and its failure caused the entire system to be shut down, significantly impacting facility operations. This paper describes the activities associated with failure characterization, technical decision making/planning for repair by welding, logistical challenges associated with performing work inmore » a radiologically controlled zone, performing the repair, and administrative considerations related to ASME code requirements.« less

  5. Focused process improvement events: sustainability of impact on process and performance in an academic radiology department.

    PubMed

    Rosenkrantz, Andrew B; Lawson, Kirk; Ally, Rosina; Chen, David; Donno, Frank; Rittberg, Steven; Rodriguez, Joan; Recht, Michael P

    2015-01-01

    To evaluate sustainability of impact of rapid, focused process improvement (PI) events on process and performance within an academic radiology department. Our department conducted PI during 2011 and 2012 in CT, MRI, ultrasound, breast imaging, and research billing. PI entailed participation by all stakeholders, facilitation by the department chair, collection of baseline data, meetings during several weeks, definition of performance metrics, creation of an improvement plan, and prompt implementation. We explore common themes among PI events regarding initial impact and durability of changes. We also assess performance in each area pre-PI, immediately post-PI, and at the time of the current study. All PI events achieved an immediate improvement in performance metrics, often entailing both examination volumes and on-time performance. IT-based solutions, process standardization, and redefinition of staff responsibilities were often central in these changes, and participants consistently expressed improved internal leadership and problem-solving ability. Major environmental changes commonly occurred after PI, including a natural disaster with equipment loss, a change in location or services offered, and new enterprise-wide electronic medical record system incorporating new billing and radiology informatics systems, requiring flexibility in the PI implementation plan. Only one PI team conducted regular post-PI follow-up meetings. Sustained improvement was frequently, but not universally, observed: in the long-term following initial PI, measures of examination volume showed continued progressive improvements, whereas measures of operational efficiency remained stable or occasionally declined. Focused PI is generally effective in achieving performance improvement, although a changing environment influences the sustainability of impact. Thus, continued process evaluation and ongoing workflow modifications are warranted. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  6. Intracranial imaging of uncommon diseases is more frequently reported in clinical publications than in radiology publications.

    PubMed

    Lehman, V T; Doolittle, D A; Hunt, C H; Eckel, L J; Black, D F; Schwartz, K M; Diehn, F E

    2014-01-01

    Descriptions of uncommon diseases with intracranial imaging abnormalities are often difficult to find in the radiology literature. We hypothesized that reported imaging findings of such conditions in the recent literature were more frequent in clinical compared with radiology journals. PubMed searches from December 1, 2007 to December 1, 2012 were performed for 5 uncommon CNS diseases with intracranial imaging manifestations: 1) Susac syndrome; 2) amyloid β-related angiitis; 3) Parry-Romberg syndrome/en coup de sabre; 4) transient lesion of the splenium of the corpus callosum; and 5) reversible cerebral vasoconstriction syndrome. Articles were classified as a case report, case series, or original research. Journals were categorized as radiology or clinical. The 1- and 5-year Impact Factors of the journals were recorded. Two hundred two articles were identified for the 5 diseases, including 151 (74%) case reports, 26 case series (13%), and 25 original research articles (13%); 179 (89%) were published in nonradiology journals, compared with 23 (11%) in radiology journals. There was no significant difference between the mean 1- and 5-year Impact Factors of the radiology and clinical journals. Recent reports of the selected uncommon diseases with intracranial manifestations are more frequent in clinical journals when compared with dedicated radiology publications. Most publications are case reports. Radiologists should review both radiology and clinical journals when reviewing imaging features of uncommon diseases affecting the brain. Lack of reporting on such disease in the radiology literature may have significant practice, educational, and research implications for the radiology community.

  7. Pediatric interventional radiology clinic - how are we doing?

    PubMed

    Rubenstein, Jonathan; Zettel, Julie C; Lee, Eric; Cote, Michelle; Aziza, Albert; Connolly, Bairbre L

    2016-07-01

    Development of a pediatric interventional radiology clinic is a necessary component of providing a pediatric interventional radiology service. Patient satisfaction is important when providing efficient, high-quality care. To analyze the care provided by a pediatric interventional radiology clinic from the perspective of efficiency and parent satisfaction, so as to identify areas for improvement. The prospective study was both quantitative and qualitative. The quantitative component measured clinic efficiency (waiting times, duration of clinic visit, nurse/physician time allocation and assessments performed; n = 91). The qualitative component assessed parental satisfaction with their experience with the pediatric interventional radiology clinic, using a questionnaire (5-point Likert scale) and optional free text section for feedback (n = 80). Questions explored the family's perception of relevance of information provided, consent process and overall satisfaction with their pediatric interventional radiology clinic experience. Families waited a mean of 11 and 10 min to meet the physician and nurse, respectively. Nurses and physicians spent a mean of 28 and 21 min with the families, respectively. The average duration of the pediatric interventional radiology clinic consultation was 56 min. Of 80 survey participants, 83% were satisfied with their experience and 94% said they believed providing consent before the day of the procedure was helpful. Only 5% of respondents were not satisfied with the time-efficiency of the interventional radiology clinic. Results show the majority of patients/parents are very satisfied with the pediatric interventional radiology clinic visit. The efficiency of the pediatric interventional radiology clinic is satisfactory; however, adherence to stricter scheduling can be improved.

  8. Using Six Sigma to improve the film library.

    PubMed

    Benedetto, Anthony R; Dunnington, Joel S; Oxford-Zelenske, Deborah

    2002-01-01

    The film library of a film-based radiology department is a mission-critical component of the department that is frequently underappreciated and under-staffed. A poorly performing film library causes operational problems for not only the radiology department, but for the institution as a whole. Since Six Sigma techniques had proved successful in an earlier CT throughput improvement project, the University of Texas M.D. Anderson Cancer Center Division of Diagnostic Imaging decided to use Six Sigma techniques to dramatically improve the performance of its film library. Nine mini-project teams were formed to address the basic operating functions of the film library. The teams included film library employees, employees from other sections of radiology, employees from stakeholders outside of radiology, and radiologists and referring physicians, as appropriate to the team's mission. Each Six Sigma team developed a process map of the current process, reviewed or acquired baseline quantitative data to assess the current level of performance, and then modified the process map to incorporate their recommendations for improving the process. An overall project steering committee reviewed recommendations from each Six Sigma team to assure that all of the teams' efforts were coordinated and aligned with the overall project goals. The steering committee also provided advice on implementation strategies, particularly for changes that would have an immediate effect on stakeholders outside of the radiology department. After implementation of recommendations, quantitative data were collected again to determine if the changes were having the desired effect. Improvement in both quantitative metrics and in employee morale have been experienced. We continue to collect data as assurance that the improvements are being sustained over the long haul. Six Sigma techniques, which are as quantitatively-based as possible, are useful in a service-oriented organization, such as a film library. The primary problem we encountered was that most of the important film library customer services are not automatically captured in the RIS or in any other information system. We had to develop manual data collection methods for most of our performance metrics. These collection methods were burden-some to the frontline employees who were required to collect the data. Additionally, we had to invest many hours of effort into assuring that the data were valid since film library employees rarely have the educational background to readily grasp the importance of the statistical methods employed in Six Sigma. One of the most important lessons we learned was that film library employees, including supervisory personnel, must be held accountable for their performance in a manner that is objective, fair and constructive. The best methods involved feedback collected by the employees themselves in the ordinary course of their duties. Another important lesson we learned was that film library employees, as well as stakeholders outside of the film library, need to understand how important the film library is to the smooth functioning of the entire institution. Significant educational efforts must be expended to show film library employees how their duties affect their film library co-workers and the institution's patients. Physicians, nurses and employees outside of the film library must do their part too, which requires educational efforts that highlight the importance of compliance with film library policies.

  9. Agreement Between Computed Tomography and Pathologic Nodule Counts in Colorectal Lung Metastases.

    PubMed

    Marron, M Carmen; Lora, David; Gamez, Pablo; Rivas, Juan J; Embun, Raul; Molins, Laureano; de la Cruz, Javier

    2016-01-01

    Computed tomography is the most common technique used to estimate the number of pulmonary metastases and their resectability. A lack of agreement between radiologic and surgical pathologic findings could potentially lead to incomplete resection or to rejection of patients for potentially curative treatments. The objective of this study was to estimate the disagreement between the number of radiologic lesions and the number of histologically confirmed malignant lesions excised from patients with pulmonary metastases from colorectal cancer. This was a multicenter longitudinal study using a national registry. All patients underwent open surgery for pulmonary metastasectomy. Radiologic unilateral involvement was documented in 345 of 404 patients (85%); 253 (73%) presented with single nodules. The radiologic and malignant pathologic findings were concordant in 316 (78%) patients. The two independent predictors of discordance between computed tomography and the number of pathologic metastases were the bilateral involvement and the number of radiologic nodules. This model explained 28% of the variability in the disagreement frequency and discriminated between agreement and disagreement in 85% of the patients. Discrepancies increased with the nodule count with an odds ratio of 6.17 (95% confidence interval, 4.08 to 9.33) per additional nodule. For similar nodule counts, a lower disagreement frequency was observed among bilateral cases (odds ratio, 0.2; 95% confidence interval, 0.07 to 0.55). Differences between the radiologic and pathologic findings were documented in 1 of every 5 patients. The correlation was very accurate in patients with single radiologic nodules. However, half of the patients with more nodules showed discrepancies. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Severe contrast reaction emergencies high-fidelity simulation training for radiology residents and technologists in a children's hospital.

    PubMed

    Tofil, Nancy M; White, Marjorie Lee; Grant, Matthew; Zinkan, J Lynn; Patel, Bhavik; Jenkins, Lynsey; Youngblood, Amber Q; Royal, Stuart A

    2010-07-01

    Severe reactions to radiographic contrast agents can be life threatening, and although they are rare, effective recognition and management are essential to improving outcomes. A high-fidelity radiology simulation course for radiology residents and technologists focusing on severe contrast reactions and immediate treatments was designed to test the hypothesis that knowledge would improve with this educational intervention. A prospective pretest and posttest study design was used. Residents and technologists worked in teams of three to five members. Learning objectives focused on demonstrating when and how to use basic life support skills and epinephrine auto-injectors. Each resident and technologist was administered a pretest prior to the start of the case scenarios and a posttest following the debriefing session. Scores from the pretest and posttest for the residents and technologists were compared using a paired-samples t test. Nineteen radiology residents and 11 radiology technologists participated. The average test scores were higher and improved significantly following the simulation experience for both the radiology residents (57% vs 82%, P < .001) and technologists (47% vs 72%, P = .006). Anonymous evaluations demonstrated that the experience was well received by residents and technologists, with 97% of learners (29 of 30) rating the experience as extremely or very helpful. Important learning themes included the knowledge of epinephrine auto-injector use and basic life support skills. High-fidelity simulation for radiology residents and technologists focusing on epinephrine auto-injector use and basic life support skills during the first 5 minutes of a severe contrast reaction can significantly improve recognition and knowledge in treating patients having severe contrast reactions. 2010 AUR. Published by Elsevier Inc. All rights reserved.

  11. Surface Radiation Survey at the Shepley’s Hill Remediation Site, Devens, Massachusettes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. R. Giles; C. P. Oertel; L. G. Roybal

    2009-09-01

    The Idaho National Laboratory (INL) provided technical support for ongoing environmental remediation activities at the Shepley’s Hill remediation site, near Devens, MA. The technical support included the completion of a radiation survey of naturally occurring radioactive materials (NORM) at Shepley’s Hill, Shepley’s Hill landfill cover, and Red Cove areas. The objective of the radiation survey was to assess the ability of the INL backpack sodium iodide spectroscopy (BaSIS) system to detect elevated levels of NORM that may be associated with radon-222 emanation from near surface and subsurface fractures in the area. It is postulated that these fracture zones provide subsurfacemore » conduits for the transport of environmental contaminants. As such, location of these fracture sets will proved EPA Region 1 with the means for completing the development of an accurate site conceptual model. The results of the radiological survey show that some of the radiological anomalies correlate with currently mapped rock outcrops; however, not all of the rock outcrops in the surveyed area have been mapped. As such, it is not conclusive that all of the radiological anomalies correspond with surface rock outcrops. EPA Region 1 intends to perform a more comprehensive correlation of the radiation data collected with the BaSIS system with additional data sets such as detailed bedrock structural mapping, 2-dimensional resistivity profiling, and high-resolution topographic mapping. The results of this effort will be used in consideration of designing a potential follow-on effort for mapping of radon.« less

  12. Invited review: study design considerations for clinical research in veterinary radiology and radiation oncology.

    PubMed

    Scrivani, Peter V; Erb, Hollis N

    2013-01-01

    High quality clinical research is essential for advancing knowledge in the areas of veterinary radiology and radiation oncology. Types of clinical research studies may include experimental studies, method-comparison studies, and patient-based studies. Experimental studies explore issues relative to pathophysiology, patient safety, and treatment efficacy. Method-comparison studies evaluate agreement between techniques or between observers. Patient-based studies investigate naturally acquired disease and focus on questions asked in clinical practice that relate to individuals or populations (e.g., risk, accuracy, or prognosis). Careful preplanning and study design are essential in order to achieve valid results. A key point to planning studies is ensuring that the design is tailored to the study objectives. Good design includes a comprehensive literature review, asking suitable questions, selecting the proper sample population, collecting the appropriate data, performing the correct statistical analyses, and drawing conclusions supported by the available evidence. Most study designs are classified by whether they are experimental or observational, longitudinal or cross-sectional, and prospective or retrospective. Additional features (e.g., controlled, randomized, or blinded) may be described that address bias. Two related challenging aspects of study design are defining an important research question and selecting an appropriate sample population. The sample population should represent the target population as much as possible. Furthermore, when comparing groups, it is important that the groups are as alike to each other as possible except for the variables of interest. Medical images are well suited for clinical research because imaging signs are categorical or numerical variables that might be predictors or outcomes of diseases or treatments. © 2013 Veterinary Radiology & Ultrasound.

  13. Hanford Radiological Protection Support Services Annual Report for 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DE Bihl; JA MacLellan; ML Johnson

    1999-05-14

    During calendar year (CY) 1998, the Pacific Northwest National Laboratory (PNNL) performed its customary radiological protection support services in support of the U.S. Department of Energy (DOE) Richland Operations OffIce (RL) and the Hanford contractors. These services included: 1) external dosimetry, 2) internal dosimetry, 3) in vivo measurements, 4) radiological records, 5) instrument calibra- tion and evaluation, and 6) calibration of radiation sources traceable to the National Institute of Standards and Technology (MST). The services were provided under a number of projects as summarized here.

  14. An indicator device for monitoring of room illuminance level in the radiological image viewing environment.

    PubMed

    Azlan, C A; Ng, K H; Anandan, S; Nizam, M S

    2006-09-01

    Illuminance level in the softcopy image viewing room is a very important factor to optimize productivity in radiological diagnosis. In today's radiological environment, the illuminance measurements are normally done during the quality control procedure and performed annually. Although the room is equipped with dimmer switches, radiologists are not able to decide the level of illuminance according to the standards. The aim of this study is to develop a simple real-time illuminance detector system to assist the radiologists in deciding an adequate illuminance level during radiological image viewing. The system indicates illuminance in a very simple visual form by using light emitting diodes. By employing the device in the viewing room, illuminance level can be monitored and adjusted effectively.

  15. ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.

    PubMed

    Vano, E; Faulkner, K

    2005-01-01

    The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protection for cardiologists performing fluoroscopically guided procedures, will be produced during 2005. This paper highlights some of the topics of the published reports, their relevance to European legislation on medical exposures and the importance of radiation protection research in underpinning the ICRP task groups' work in to producing these documents. It is also anticipated that the results, obtained in the cardiology work package of the European research project, will be used in the new document on radiation protection for cardiologists.

  16. On-line data collection platform for national dose surveys in diagnostic and interventional radiology.

    PubMed

    Vassileva, J; Simeonov, F; Avramova-Cholakova, S

    2015-07-01

    According to the Bulgarian regulation for radiation protection at medical exposure, the National Centre of Radiobiology and Radiation Protection (NCRRP) is responsible for performing national dose surveys in diagnostic and interventional radiology and nuclear medicine and for establishing of national diagnostic reference levels (DRLs). The next national dose survey is under preparation to be performed in the period of 2015-16, with the aim to cover conventional radiography, mammography, conventional fluoroscopy, interventional and fluoroscopy guided procedures and CT. It will be performed electronically using centralised on-line data collection platform established by the NCRRP. The aim is to increase the response rate and to improve the accuracy by reducing human errors. The concept of the on-line dose data collection platform is presented. Radiological facilities are provided with a tool to determine local typical patient doses, and the NCRRP to establish national DRLs. Future work will include automatic retrieval of dose data from hospital picture archival and communicating system. The on-line data collection platform is expected to facilitate the process of dose audit and optimisation of radiological procedures in Bulgarian hospitals. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. A Single-Center Experience With Isolated Limb Infusion: An Interventional Oncology Opportunity.

    PubMed

    DeFoe, Adam; Heckman, Andrew; Slater, Dick; Silva-Lopez, Edibaldo; Foster, Jason; Bowden, Thom; Vargo, Christopher

    2017-03-01

    This retrospective review details our experience with isolated limb infusion for the treatment of melanoma, squamous cell carcinoma, and sarcoma in-transit metastases performed entirely in the interventional radiology suite. Eleven patients were treated over a 3-year period. Treatment response was assessed clinically and with PET/CT. Eight patients had either complete or partial response, giving an overall response rate of 72%. Isolated limb infusion can efficiently be performed entirely in the interventional radiology suite.

  18. Consensus Statement of Society of Abdominal Radiology Disease-Focused Panel on Barium Esophagography in Gastroesophageal Reflux Disease.

    PubMed

    Levine, Marc S; Carucci, Laura R; DiSantis, David J; Einstein, David M; Hawn, Mary T; Martin-Harris, Bonnie; Katzka, David A; Morgan, Desiree E; Rubesin, Stephen E; Scholz, Francis J; Turner, Mary Ann; Wolf, Ellen L; Canon, Cheri L

    2016-11-01

    The Society of Abdominal Radiology established a panel to prepare a consensus statement on the role of barium esophagography in gastroesophageal reflux disease (GERD), as well as recommended techniques for performing the fluoroscopic examination and the gamut of findings associated with this condition. Because it is an inexpensive, noninvasive, and widely available study that requires no sedation, barium esophagography may be performed as the initial test for GERD or in conjunction with other tests such as endoscopy.

  19. Multiservice Tactics, Techniques, and Procedures for Chemical, Biological, Radiological and Nuclear Contamination Avoidance

    DTIC Science & Technology

    2006-02-01

    Radiological and Nuclear Contamination Avoidance 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) 5d. PROJECT NUMBER 5e. TASK...NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME( S ) AND ADDRESS(ES) Federation of American Scientists 1717 K St., NW Suite 209 Washington...DC 20036 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME( S ) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM( S ) 11

  20. Limitations Influencing Interventional Radiology in Canada: Results of a National Survey by the Canadian Interventional Radiology Association (CIRA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Brien, Jeremy; Baerlocher, Mark Otto; Asch, Murray R.

    2007-09-15

    Purpose. To describe the current state and limitations to interventional radiology (IR) in Canada through a large, national survey of Canadian interventional radiologists. Methods. An anonymous online survey was offered to members of the Canadian Interventional Radiology Association (CIRA). Only staff radiologists were invited to participate. Results. Seventy-five (75) responses were received from a total of 247, giving a response rate of 30%. Respondents were split approximately equally between academic centers (47%) and community practice (53%), and the majority of interventional radiologists worked in hospitals with either 200-500 (49%) or 500-1,000 (39%) beds. Procedures listed by respondents as most commonlymore » performed in their practice included PICC line insertion (83%), angiography and stenting (65%), and percutaneous biopsy (37%). Procedures listed as not currently performed but which interventional radiologists believed would benefit their patient population included radiofrequency ablation (36%), carotid stenting (34%), and aortic stenting (21%); the majority of respondents noted that a lack of support from referring services was the main reason for not performing these procedures (56%). Impediments to increasing scope and volume of practice in Canadian IR were most commonly related to room or equipment shortage (35%), radiologist shortage (33%), and a lack of funding or administrative support (28%). Conclusion. Interventional radiology in Canada is limited by a number of factors including funding, manpower, and referral support. A concerted effort should be undertaken by individual interventional radiologists and IR organizations to increase training capacity, funding, remuneration, and public exposure to IR in order to help advance the subspecialty.« less

  1. The public cancer radiology imaging collections of The Cancer Imaging Archive.

    PubMed

    Prior, Fred; Smith, Kirk; Sharma, Ashish; Kirby, Justin; Tarbox, Lawrence; Clark, Ken; Bennett, William; Nolan, Tracy; Freymann, John

    2017-09-19

    The Cancer Imaging Archive (TCIA) is the U.S. National Cancer Institute's repository for cancer imaging and related information. TCIA contains 30.9 million radiology images representing data collected from approximately 37,568 subjects. This data is organized into collections by tumor-type with many collections also including analytic results or clinical data. TCIA staff carefully de-identify and curate all incoming collections prior to making the information available via web browser or programmatic interfaces. Each published collection within TCIA is assigned a Digital Object Identifier that references the collection. Additionally, researchers who use TCIA data may publish the subset of information used in their analysis by requesting a TCIA generated Digital Object Identifier. This data descriptor is a review of a selected subset of existing publicly available TCIA collections. It outlines the curation and publication methods employed by TCIA and makes available 15 collections of cancer imaging data.

  2. Bridging the Gap between Basic and Clinical Sciences: A Description of a Radiological Anatomy Course

    ERIC Educational Resources Information Center

    Torres, Anna; Staskiewicz, Grzegorz J.; Lisiecka, Justyna; Pietrzyk, Lukasz; Czekajlo, Michael; Arancibia, Carlos U.; Maciejewski, Ryszard; Torres, Kamil

    2016-01-01

    A wide variety of medical imaging techniques pervade modern medicine, and the changing portability and performance of tools like ultrasound imaging have brought these medical imaging techniques into the everyday practice of many specialties outside of radiology. However, proper interpretation of ultrasonographic and computed tomographic images…

  3. Experience-based consulting: the value proposition.

    PubMed

    Pliner, Nicole; Thrall, James; Boland, Giles; Palumbo, Denise

    2004-11-01

    Consulting is a profession universally accepted and well entrenched throughout the business world. Whether it is providing objective analysis, supplying a specific expertise, managing a project, or simply adding extra manpower, consultants can add value. However, what are the attributes of a good consultant? In health care, with the rapid pace of emerging technologies, economic intricacies, and the complexities of clinical care, hands-on experience is the key. Recognizing the power of consultants with hands-on experience, the Department of Radiology at Massachusetts General Hospital launched the Radiology Consulting Group, an "experience-based" model for consulting that may potentially shift the profession's paradigm.

  4. How visual search relates to visual diagnostic performance: a narrative systematic review of eye-tracking research in radiology.

    PubMed

    van der Gijp, A; Ravesloot, C J; Jarodzka, H; van der Schaaf, M F; van der Schaaf, I C; van Schaik, J P J; Ten Cate, Th J

    2017-08-01

    Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review of eye-tracking literature in the radiology domain aims to identify visual search patterns associated with high perceptual performance. Databases PubMed, EMBASE, ERIC, PsycINFO, Scopus and Web of Science were searched using 'visual perception' OR 'eye tracking' AND 'radiology' and synonyms. Two authors independently screened search results and included eye tracking studies concerning visual skills in radiology published between January 1, 1994 and July 31, 2015. Two authors independently assessed study quality with the Medical Education Research Study Quality Instrument, and extracted study data with respect to design, participant and task characteristics, and variables. A thematic analysis was conducted to extract and arrange study results, and a textual narrative synthesis was applied for data integration and interpretation. The search resulted in 22 relevant full-text articles. Thematic analysis resulted in six themes that informed the relation between visual search and level of expertise: (1) time on task, (2) eye movement characteristics of experts, (3) differences in visual attention, (4) visual search patterns, (5) search patterns in cross sectional stack imaging, and (6) teaching visual search strategies. Expert search was found to be characterized by a global-focal search pattern, which represents an initial global impression, followed by a detailed, focal search-to-find mode. Specific task-related search patterns, like drilling through CT scans and systematic search in chest X-rays, were found to be related to high expert levels. One study investigated teaching of visual search strategies, and did not find a significant effect on perceptual performance. Eye tracking literature in radiology indicates several search patterns are related to high levels of expertise, but teaching novices to search as an expert may not be effective. Experimental research is needed to find out which search strategies can improve image perception in learners.

  5. Spanish Radiology in the second half of the XX Century: a view from inside.

    PubMed

    Bonmatí, José

    2008-09-01

    Radiology was born in 1896 with the immediate recognition of the diagnostic value of X-rays in medicine and progressed throughout the XX Century with the increasing knowledge of its properties and clinical applications. By mid-century Radiology was a respected clinical specialty in advanced countries, the radiological report was a requirement in hospital practice and radiologists' opinions requested in scientific meetings. In the last decades of the century has had a spectacular expansion with the emergence of new imaging modalities and revolutionary technologies that have transformed the specialty worldwide. In Spain Radiology lagged behind needs and demand in 1950. Radiological practice was unregulated and performance of X-ray exams by non-radiologists was common. Teaching of Radiology was non-existent in Medical Schools or postgraduation. The diagnostic value of the specialty was unrecognized by physicians and the role of radiologists ignored. Most hospital radiology services were poorly equipped and functionally inadequate. The shadow of the Civil War (1936-39) was conditioning Radiology in the country. The point of inflexion in the development of Radiology in Spain was the inclusion of film reading sessions in the 1965 academic program of the Society of Radiology. It was in the presentation of cases at these conferences that Clinical Radiology found the finest demonstration ground and as a result was immediately adopted by radiologists and progressively applied in scientific meetings, clinical practices and training programs. Its influence was important in reforming hospital practice, legislation on specialization and education, as well as in national health care plans. At the end of the century radiology in Spain was at a par with the standards of other western nations. The author was a witness of the evolution of Radiology during his 50 years of professional life. This article does not pretend to be exhaustive in names or contributions. It is an overview of the period from the perspective of his past experience and seen from the distance of events that influenced the course of developments. I hope that those interested in the subject find that the effort has been worthwhile and helpful.

  6. Strategies for the promotion of computer applications in radiology in healthcare delivery.

    PubMed

    Reiner, B; Siegel, E; Allman, R

    1998-08-01

    The objective of this paper is to identify current trends in the development and implementation of computer applications in today's ever-changing healthcare environment. Marketing strategies are discussed with the goal of promoting computer applications in radiology as a means to advance future healthcare acceptance of technologic developments from the medical imaging field. With the rapid evolution of imaging and and information technologies along with the transition to filmless imaging, radiologists must assume a proactive role in the development and application of these advancements. This expansion can be accomplished in a number of ways including internet based educational programs, research partnerships, and professional membership in societies such as the Society of Computer Applications in Radiology (SCAR). Professional societies such as SCAR, in turn, should reach out to include other professionals from the healthcare community. These would include financial, administrative, and information systems disciplines to promote these technologies in a cost conscious and value added manner.

  7. [Digital radiography in young children. Considerations based on experiences in practice].

    PubMed

    Berkhout, W E R; Mileman, P A; Weerheijm, K L

    2004-10-01

    In dentistry, digital radiology techniques, such as a charge-coupled device and a storage phosphor plate, are gaining popularity. It was the objective of this study to assess the importance of the advantages and disadvantages of digital radiology techniques for bitewing radiography in young children, when compared to conventional film. A group of dentists received a questionnaire regarding their experiences with digital radiology techniques or conventional films among young children. Using the Simple Multi-Attributive Rating Technique (SMART) a final weighted score was calculated for the charge-coupled device, the phosphor plate, and conventional film. The scores were 7.40, 7.38, and 6.98 respectively. The differences were not statistically significant (p > 0.47). It could be concluded that, on the basis of experiences in practice, there are no statistically significant preferences for the use of digital radioogy techniques for bitewing radiography in young children.

  8. [Silicosis: computed tomography findings].

    PubMed

    González Vázquez, M; Trinidad López, C; Castellón Plaza, D; Calatayud Moscoso Del Prado, J; Tardáguila Montero, F

    2013-01-01

    Silicosis is an occupational lung disease, which is caused by the inhalation of silica and affects a wide range of jobs. There are many clinical forms of silicosis: acute silicosis, results from exposure to very large amounts of silica dust over a period of less than 2 years. Simple chronic silicosis, the most common type that we see today, results from exposure to low amounts of silica between 2 and 10 years. Chronic silicosis complicated, with silicotic conglomerates. In many cases the diagnosis of silicosis is made according to epidemiological and radiological data, without a histological confirmation. It is important to know the various radiological manifestations of silicosis to differentiate it from other lung diseases and to recognize their complications. The objective of this work is to describe typical and atypical radiological findings of silicosis and their complications in helical and high resolution (HRCT) thorax CT. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  9. Occupational dose in interventional radiology procedures.

    PubMed

    Chida, Koichi; Kaga, Yuji; Haga, Yoshihiro; Kataoka, Nozomi; Kumasaka, Eriko; Meguro, Taiichiro; Zuguchi, Masayuki

    2013-01-01

    Interventional radiology tends to involve long procedures (i.e., long fluoroscopic times). Therefore, radiation protection for interventional radiology staff is an important issue. This study describes the occupational radiation dose for interventional radiology staff, especially nurses, to clarify the present annual dose level for interventional radiology nurses. We compared the annual occupational dose (effective dose and dose equivalent) among interventional radiology staff in a hospital where 6606 catheterization procedures are performed annually. The annual occupational doses of 18 physicians, seven nurses, and eight radiologic technologists were recorded using two monitoring badges, one worn over and one under their lead aprons. The annual mean ± SD effective dose (range) to the physicians, nurses, and radiologic technologists using two badges was 3.00 ± 1.50 (0.84-6.17), 1.34 ± 0.55 (0.70-2.20), and 0.60 ± 0.48 (0.02-1.43) mSv/y, respectively. Similarly, the annual mean ± SD dose equivalent range was 19.84 ± 12.45 (7.0-48.5), 4.73 ± 0.72 (3.9-6.2), and 1.30 ± 1.00 (0.2-2.7) mSv/y, respectively. The mean ± SD effective dose for the physicians was 1.02 ± 0.74 and 3.00 ± 1.50 mSv/y for the one- and two-badge methods, respectively (p < 0.001). Similarly, the mean ± SD effective dose for the nurses (p = 0.186) and radiologic technologists (p = 0.726) tended to be lower using the one-badge method. The annual occupational dose for interventional radiology staff was in the order physicians > nurses > radiologic technologists. The occupational dose determined using one badge under the apron was far lower than the dose obtained with two badges in both physicians and nonphysicians. To evaluate the occupational dose correctly, we recommend use of two monitoring badges to evaluate interventional radiology nurses as well as physicians.

  10. Analysis of fission and activation radionuclides produced by a uranium-fueled nuclear detonation and identification of the top dose-producing radionuclides.

    PubMed

    Kraus, Terry; Foster, Kevin

    2014-08-01

    The radiological assessment of the nuclear fallout (i.e., fission and neutron-activation radionuclides) from a nuclear detonation is complicated by the large number of fallout radionuclides. This paper provides the initial isotopic source term inventory of the fallout from a uranium-fueled nuclear detonation and identifies the significant and insignificant radiological dose producing radionuclides over 11 dose integration time periods (time phases) of interest. A primary goal of this work is to produce a set of consistent, time phase-dependent lists of the top dose-producing radionuclides that can be used to prepare radiological assessment calculations and data products (e.g., maps of areas that exceed protective action guidelines) in support of public and worker protection decisions. The ranked lists of top dose-producing radionuclides enable assessors to perform atmospheric dispersion modeling and radiological dose assessment modeling more quickly by using relatively short lists of radionuclides without significantly compromising the accuracy of the modeling and the dose projections. This paper also provides a superset-list of the top dose-producing fallout radionuclides from a uranium-fueled nuclear detonation that can be used to perform radiological assessments over any desired time phase. Furthermore, this paper provides information that may be useful to monitoring and sampling and laboratory analysis personnel to help understand which radionuclides are of primary concern. Finally, this paper may be useful to public protection decision makers because it shows the importance of quickly initiating public protection actions to minimize the radiological dose from fallout.

  11. Assessing the value of diagnostic imaging: the role of perception

    NASA Astrophysics Data System (ADS)

    Potchen, E. J.; Cooper, Thomas G.

    2000-04-01

    The value of diagnostic radiology rests in its ability to provide information. Information is defined as a reduction in randomness. Quality improvement in any system requires diminution in the variation in its performance. The major variation in performance of the system of diagnostic radiology occurs in observer performance and in the communication of information from the observer to someone who will apply that information to the benefit of the patient. The ability to provide information can be determined by observer performance studies using a receiver-operating characteristic (ROC) curve analysis. The amount of information provided by each observer can be measured in terms of the uncertainty they reduce. Using a set of standardized radiographs, some normal and some abnormal, sorting them randomly, and then asking an observer to redistribute them according to their probability of normality can measure the difference in the value added by different observers. By applying this observer performance measure, we have been able to characterize individual radiologists, groups of radiologists, and regions of the United States in their ability to add value in chest radiology. The use of these technologies in health care may improve upon the contribution of diagnostic imaging.

  12. Anismus, Physiology, Radiology: Is It Time for Some Pragmatism? A Comparative Study of Radiological and Anorectal Physiology Findings in Patients With Anismus.

    PubMed

    Pisano, Umberto; Irvine, Lesley; Szczachor, Justina; Jawad, Ahsin; MacLeod, Andrew; Lim, Michael

    2016-10-01

    Anismus is a functional disorder featuring obstructive symptoms and paradoxical contractions of the pelvic floor. This study aims to establish diagnosis agreement between physiology and radiology, associate anismus with morphological outlet obstruction, and explore the role of sphincteric pressure and rectal volumes in the radiological diagnosis of anismus. Consecutive patients were evaluated by using magnetic resonance imaging proctography/fluoroscopic defecography and anorectal physiology. Morphological radiological features were associated with physiology tests. A categorical analysis was performed using the chi-square test, and agreement was assessed via the kappa coefficient. A Mann-Whitney test was used to assess rectal volumes and sphincterial pressure distributions between groups of patients. A P-value of <0.05 was significant. Forty-three patients (42 female patients) underwent anorectal physiology and radiology imaging. The median age was 54 years (interquartile range, 41.5-60 years). Anismus was seen radiologically and physiologically in 18 (41.8%) and 12 patients (27.9%), respectively. The agreement between modalities was 0.298 (P = 0.04). Using physiology as a reference, radiology had positive and negative predictive values of 44% and 84%, respectively. Rectoceles, cystoceles, enteroceles and pathological pelvic floor descent were not physiologically predictive of animus (P > 0.05). The sphincterial straining pressure was 71 mmHg in the anismus group versus 12 mmHg. Radiology was likely to identify anismus when the straining pressure exceeded 50% of the resting pressure (P = 0.08). Radiological techniques detect pelvic morphological abnormalities, but lead to overdiagnoses of anismus. No proctographic pathological feature predicts anismus reliably. A stronger pelvic floor paradoxical contraction is associated with a greater likelihood of detection by proctography.

  13. Anismus, Physiology, Radiology: Is It Time for Some Pragmatism? A Comparative Study of Radiological and Anorectal Physiology Findings in Patients With Anismus

    PubMed Central

    Irvine, Lesley; Szczachor, Justina; Jawad, Ahsin; MacLeod, Andrew; Lim, Michael

    2016-01-01

    Purpose Anismus is a functional disorder featuring obstructive symptoms and paradoxical contractions of the pelvic floor. This study aims to establish diagnosis agreement between physiology and radiology, associate anismus with morphological outlet obstruction, and explore the role of sphincteric pressure and rectal volumes in the radiological diagnosis of anismus. Methods Consecutive patients were evaluated by using magnetic resonance imaging proctography/fluoroscopic defecography and anorectal physiology. Morphological radiological features were associated with physiology tests. A categorical analysis was performed using the chi-square test, and agreement was assessed via the kappa coefficient. A Mann-Whitney test was used to assess rectal volumes and sphincterial pressure distributions between groups of patients. A P-value of <0.05 was significant. Results Forty-three patients (42 female patients) underwent anorectal physiology and radiology imaging. The median age was 54 years (interquartile range, 41.5–60 years). Anismus was seen radiologically and physiologically in 18 (41.8%) and 12 patients (27.9%), respectively. The agreement between modalities was 0.298 (P = 0.04). Using physiology as a reference, radiology had positive and negative predictive values of 44% and 84%, respectively. Rectoceles, cystoceles, enteroceles and pathological pelvic floor descent were not physiologically predictive of animus (P > 0.05). The sphincterial straining pressure was 71 mmHg in the anismus group versus 12 mmHg. Radiology was likely to identify anismus when the straining pressure exceeded 50% of the resting pressure (P = 0.08). Conclusion Radiological techniques detect pelvic morphological abnormalities, but lead to overdiagnoses of anismus. No proctographic pathological feature predicts anismus reliably. A stronger pelvic floor paradoxical contraction is associated with a greater likelihood of detection by proctography. PMID:27847787

  14. Outcome Following a Negative CT Angiogram for Gastrointestinal Hemorrhage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, Victoria, E-mail: drvictoriac@gmail.com; Tse, Donald, E-mail: donald.tse@gmail.com; Dixon, Shaheen, E-mail: shaheen7noorani@gmail.com

    2015-04-15

    ObjectiveThis study was designed to evaluate the role of a negative computed tomography angiogram (CTA) in patients who present with gastrointestinal (GI) hemorrhage.MethodsA review of all patients who had CTAs for GI hemorrhage over an 8-year period from January 2005 to December 2012 was performed. Data for patient demographics, location of hemorrhage, hemodynamic stability, and details of angiograms and/or the embolization procedure were obtained from the CRIS/PACS database, interventional radiology database, secure electronic medical records, and patient’s clinical notes.ResultsA total of 180 patients had 202 CTAs during the 8-year period: 87 CTAs were performed for upper GI hemorrhage (18 positivemore » for active bleeding, 69 negative) and 115 for lower GI hemorrhage (37 positive for active bleeding, 78 negative); 58.7 % (37/63) of patients with upper GI bleed and 77.4 % (48/62) of patients with lower GI bleed who had an initial negative CTA did not rebleed without the need for radiological or surgical intervention. This difference was statistically significant (p = 0.04). The relative risk of rebleeding, following a negative CTA, in lower GI bleeding versus upper GI bleeding patients is 0.55 (95 % confidence interval 0.32–0.95).ConclusionsPatients with upper GI bleed who had negative CTAs usually require further intervention to stop the bleeding. In contrast, most patients presenting with lower GI hemorrhage who had a negative first CTA were less likely to rebleed.« less

  15. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy.

    PubMed

    Naqvi, Hanna; Edhi, Muhammad Muzzammil; Aslam, Hafiz Muhammad; Faridi, Naveen

    2013-02-12

    Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis.

  16. Value management program: performance, quantification, and presentation of imaging value-added actions.

    PubMed

    Patel, Samir

    2015-03-01

    Health care is in a state of transition, shifting from volume-based success to value-based success. Hospital executives and referring physicians often do not understand the total value a radiology group provides. A template for easy, cost-effective implementation in clinical practice for most radiology groups to demonstrate the value they provide to their clients (patients, physicians, health care executives) has not been well described. A value management program was developed to document all of the value-added activities performed by on-site radiologists, quantify them in terms of time spent on each activity (investment), and present the benefits to internal and external stakeholders (outcomes). The radiology value-added matrix is the platform from which value-added activities are categorized and synthesized into a template for defining investments and outcomes. The value management program was first implemented systemwide in 2013. Across all serviced locations, 9,931.75 hours were invested. An annual executive summary report template demonstrating outcomes is given to clients. The mean and median individual value-added hours per radiologist were 134.52 and 113.33, respectively. If this program were extrapolated to the entire field of radiology, approximately 30,000 radiologists, this would have resulted in 10,641,161 uncompensated value-added hours documented in 2013, with an estimated economic value of $2.21 billion. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. Strategic planning and radiology practice management in the new health care environment.

    PubMed

    Sharpe, Richard E; Mehta, Tejas S; Eisenberg, Ronald L; Kruskal, Jonathan B

    2015-01-01

    Current comprehensive health care reform in the United States demands that policy makers, insurers, providers, and patients work in reshaping the health care system to deliver care that is both more affordable and of higher quality. A tectonic shift is under way that runs contrary to the traditional goal of radiology groups to perform and interpret large numbers of imaging examinations. In fact, radiology service requisitions now must be evaluated for their appropriateness, possibly resulting in a reduction in the number of imaging studies performed. To be successful, radiology groups will have to restructure their business practices and strategies to align with the emerging health care paradigm. This article outlines a four-stage strategic framework that has aided corporations in achieving their goals and that can be readily adapted and applied by radiologists. The four stages are (a) definition and articulation of a purpose, (b) clear definition of strategic goals, (c) prioritization of specific strategic enablers, and (d) implementation of processes for tracking progress and enabling continuous adaptation. The authors provide practical guidance for applying specific tools such as analyses of strengths, weaknesses, opportunities, and threats (so-called SWOT analyses), prioritization matrices, and balanced scorecards to accomplish each stage. By adopting and applying these tools within the strategic framework outlined, radiology groups can position themselves to succeed in the evolving health care environment. RSNA, 2015

  18. Organizational decentralization in radiology.

    PubMed

    Aas, I H Monrad

    2006-01-01

    At present, most hospitals have a department of radiology where images are captured and interpreted. Decentralization is the opposite of centralization and means 'away from the centre'. With a Picture Archiving and Communication System (PACS) and broadband communications, transmitting radiology images between sites will be far easier than before. Qualitative interviews of 26 resource persons were performed in Norway. There was a response rate of 90%. Decentralization of radiology interpretations seems less relevant than centralization, but several forms of decentralization have a role to play. The respondents mentioned several advantages, including exploitation of capacity and competence. They also mentioned several disadvantages, including splitting professional communities and reduced contact between radiologists and clinicians. With the new technology decentralization and centralization of image interpretation are important possibilities in organizational change. This will be important for the future of teleradiology.

  19. Is the timing of radiological intervention and treatment day associated with economic outcomes in DRG-financed health care systems: a case study.

    PubMed

    Napierala, Christoph; Boes, Stefan

    2017-02-28

    In 2012, Switzerland has introduced a diagnosis related group (DRG) system for hospital financing to increase the efficiency and transparency of hospital services and to reduce costs. However, little is known about the efficiency of specific processes within hospitals. The objective of this study is to describe the relationship between timing of radiological interventions, in particular scan and treatment day, and the length of stay (LOS) compliance in a hospital. This is a cross-sectional observational study based on administrative records of all DRG cases in a Swiss university hospital in 2013, enriched by data from the radiology information system and accounting details. The data are analysed using descriptive statistics and regression methods. Radiology and related treatment on a weekend is associated with a higher LOS compliance of approximately 22.12% (p<0.01) compared to scans and treatments on weekdays, controlling for gender, age and insurance of the patient, as well as detailed medical and radiology-related factors. The higher LOS compliance is driven by emergency cases, which supports the hypothesis that for those cases on weekends more efficient scan and treatment processes are in place. The study provides evidence on how days of radiological intervention are related to LOS compliance in a Swiss hospital under DRG and attempts to explain how this is linked to standardised operating procedures. Our results have implications regarding potential cost savings in hospital care through alignment of care processes, infrastructure planning and guidance of patient flows.

  20. Nuclear security and radiological preparedness for the olympic games, athens 2004: lessons learned for organizing major public events.

    PubMed

    Kamenopoulou, Vassiliki; Dimitriou, Panayiotis; Hourdakis, Constantine J; Maltezos, Antonios; Matikas, Theodore; Potiriadis, Constantinos; Camarinopoulos, Leonidas

    2006-10-01

    In light of the exceptional circumstances that arose from hosting the Olympic Games in Athens in 2004 and from recent terrorist events internationally, Greece attributes the highest priority to security issues. According to its statutory role, the Greek Atomic Energy Commission is responsible for emergency preparedness and response in case of nuclear and radiological events, and advises the Government on the measures and interventions necessary to protect the public. In this context, the Commission participated in the Nuclear, Radiological, Biological, and Chemical Threat National Emergency Plan, specially developed for the Olympic Games, and coordinated by the Olympic Games Security Division. The objective of this paper is to share the experience gained during the organization of the Olympic Games and to present the nuclear security program implemented prior to, during, and beyond the Games, in order to prevent, detect, assess, and respond to the threat of nuclear terrorism. This program adopted a multi-area coverage of nuclear security, including physical protection of nuclear and radiological facilities, prevention of smuggling of radioactive materials through borders, prevention of dispersion of these materials into the Olympic venues, enhancement of emergency preparedness and response to radiological events, upgrading of the technical infrastructure, establishment of new procedures for assessing the threat and responding to radiological incidents, and training personnel belonging to several organizations involved in the National Emergency Response Plan. Finally, the close cooperation of Greek Authorities with the International Atomic Energy Agency and the U.S. Department of Energy, under the coordination of the Greek Atomic Energy Commission, is also discussed.

  1. Teaching the Healthcare Economics Milestones to Radiology Residents: Our Pilot Curriculum Experience.

    PubMed

    Prober, Allen S; Mehan, William A; Bedi, Harprit S

    2016-07-01

    Since July 2013, the Accreditation Council for Graduate Medical Education (ACGME) has required radiology residency programs to implement a set of educational milestones to track residents' educational advancement in six core competencies, including Systems-based Practice. The healthcare economics subcompetency of Systems-based Practice has traditionally been relatively neglected, and given the new increased ACGME oversight, will specifically require greater focused attention. A multi-institutional health-care economics pilot curriculum combining didactic and practical components was implemented across five residency programs. The didactic portion included a package of online recorded presentations, reading, and testing materials developed by the American College of Radiology (ACR's) Radiology Leadership Institute. The practical component involved a series of local meetings led by program faculty with the production of a deliverable based on research of local reimbursement for a noncontrast head computed tomography. The capstone entailed the presentation of each program's deliverable during a live teleconference webcast with a Radiology Leadership Institute content expert acting as moderator and discussion leader. The pilot curriculum was well received by residents and faculty moderators, with 100% of survey respondents agreeing that the pilot met its objective of introducing how reimbursement works in American radiology in 2015 and how business terminology applies to their particular institutions. A health-care economics curriculum in the style of a Massive Open Online Course has strong potential to serve as many residency programs' method of choice in meeting the health-care economics milestones. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  2. Sedation/anaesthesia in paediatric radiology

    PubMed Central

    Arlachov, Y; Ganatra, R H

    2012-01-01

    Objectives In this article we will give a comprehensive literature review on sedation/general anaesthesia (S/GA) and discuss the international variations in practice and options available for S/GA for imaging children. Methods The key articles were obtained primarily from PubMed, MEDLINE, ERIC, NHS Evidence and The Cochrane Library. Results Recently, paediatric radiology has seen a surge of diagnostic and therapeutic procedures, some of which require children to be still and compliant for up to 1 h. It is difficult and sometimes even impossible to obtain quick and high-quality images without employing sedating techniques in certain children. As with any medical procedure, S/GA in radiological practice is not without risks and can have potentially disastrous consequences if mismanaged. In order to reduce any complications and practice safety in radiological units, it is imperative to carry out pre-sedation assessments of children, obtain parental/guardian consent, monitor them closely before, during and after the procedure and have adequate equipment, a safe environment and a well-trained personnel. Conclusion Although the S/GA techniques, sedative drugs and personnel involved vary from country to country, the ultimate goal of S/GA in radiology remains the same; namely, to provide safety and comfort for the patients. Advances in knowledge Imaging children under general anaesthesia is becoming routine and preferred by operators because it ensures patient conformity and provides a more controlled environment. PMID:22898157

  3. Why Isn't There More High-fidelity Simulation Training in Diagnostic Radiology? Results of a Survey of Academic Radiologists.

    PubMed

    Cook, Tessa S; Hernandez, Jessica; Scanlon, Mary; Langlotz, Curtis; Li, Chun-Der L

    2016-07-01

    Despite its increasing use in training other medical specialties, high-fidelity simulation to prepare diagnostic radiology residents for call remains an underused educational resource. To attempt to characterize the barriers toward adoption of this technology, we conducted a survey of academic radiologists and radiology trainees. An Institutional Review Board-approved survey was distributed to the Association of University Radiologists members via e-mail. Survey results were collected electronically, tabulated, and analyzed. A total of 68 survey responses representing 51 programs were received from program directors, department chairs, chief residents, and program administrators. The most common form of educational activity for resident call preparation was lectures. Faculty supervised "baby call" was also widely reported. Actual simulated call environments were quite rare with only three programs reporting this type of educational activity. Barriers to the use of simulation include lack of faculty time, lack of faculty expertise, and lack of perceived need. High-fidelity simulation can be used to mimic the high-stress, high-stakes independent call environment that the typical radiology resident encounters during the second year of training, and can provide objective data for program directors to assess the Accreditation Council of Graduate Medical Education milestones. We predict that this technology will begin to supplement traditional diagnostic radiology teaching methods and to improve patient care and safety in the next decade. Published by Elsevier Inc.

  4. Gamma-Ray imaging for nuclear security and safety: Towards 3-D gamma-ray vision

    NASA Astrophysics Data System (ADS)

    Vetter, Kai; Barnowksi, Ross; Haefner, Andrew; Joshi, Tenzing H. Y.; Pavlovsky, Ryan; Quiter, Brian J.

    2018-01-01

    The development of portable gamma-ray imaging instruments in combination with the recent advances in sensor and related computer vision technologies enable unprecedented capabilities in the detection, localization, and mapping of radiological and nuclear materials in complex environments relevant for nuclear security and safety. Though multi-modal imaging has been established in medicine and biomedical imaging for some time, the potential of multi-modal data fusion for radiological localization and mapping problems in complex indoor and outdoor environments remains to be explored in detail. In contrast to the well-defined settings in medical or biological imaging associated with small field-of-view and well-constrained extension of the radiation field, in many radiological search and mapping scenarios, the radiation fields are not constrained and objects and sources are not necessarily known prior to the measurement. The ability to fuse radiological with contextual or scene data in three dimensions, in analog to radiological and functional imaging with anatomical fusion in medicine, provides new capabilities enhancing image clarity, context, quantitative estimates, and visualization of the data products. We have developed new means to register and fuse gamma-ray imaging with contextual data from portable or moving platforms. These developments enhance detection and mapping capabilities as well as provide unprecedented visualization of complex radiation fields, moving us one step closer to the realization of gamma-ray vision in three dimensions.

  5. Incorporating Radiology into Medical Gross Anatomy: Does the Use of Cadaver CT Scans Improve Students' Academic Performance in Anatomy?

    ERIC Educational Resources Information Center

    Lufler, Rebecca S.; Zumwalt, Ann C.; Romney, Carla A.; Hoagland, Todd M.

    2010-01-01

    Radiological images show anatomical structures in multiple planes and may be effective for teaching anatomical spatial relationships, something that students often find difficult to master. This study tests the hypotheses that (1) the use of cadaveric computed tomography (CT) scans in the anatomy laboratory is positively associated with…

  6. Occupational Analysis: Hospital Radiologic Technologist. The UCLA Allied Health Professions Project.

    ERIC Educational Resources Information Center

    Reeder, Glenn D.; And Others

    In an effort to meet the growing demand for skilled radiologic technologists and other supportive personnel educated through the associate degree level, a national survey was conducted as part of the UCLA Allied Health Professions Project to determine the tasks performed by personnel in the field and lay the groundwork for development of…

  7. Disease quantification on PET/CT images without object delineation

    NASA Astrophysics Data System (ADS)

    Tong, Yubing; Udupa, Jayaram K.; Odhner, Dewey; Wu, Caiyun; Fitzpatrick, Danielle; Winchell, Nicole; Schuster, Stephen J.; Torigian, Drew A.

    2017-03-01

    The derivation of quantitative information from images to make quantitative radiology (QR) clinically practical continues to face a major image analysis hurdle because of image segmentation challenges. This paper presents a novel approach to disease quantification (DQ) via positron emission tomography/computed tomography (PET/CT) images that explores how to decouple DQ methods from explicit dependence on object segmentation through the use of only object recognition results to quantify disease burden. The concept of an object-dependent disease map is introduced to express disease severity without performing explicit delineation and partial volume correction of either objects or lesions. The parameters of the disease map are estimated from a set of training image data sets. The idea is illustrated on 20 lung lesions and 20 liver lesions derived from 18F-2-fluoro-2-deoxy-D-glucose (FDG)-PET/CT scans of patients with various types of cancers and also on 20 NEMA PET/CT phantom data sets. Our preliminary results show that, on phantom data sets, "disease burden" can be estimated to within 2% of known absolute true activity. Notwithstanding the difficulty in establishing true quantification on patient PET images, our results achieve 8% deviation from "true" estimates, with slightly larger deviations for small and diffuse lesions where establishing ground truth becomes really questionable, and smaller deviations for larger lesions where ground truth set up becomes more reliable. We are currently exploring extensions of the approach to include fully automated body-wide DQ, extensions to just CT or magnetic resonance imaging (MRI) alone, to PET/CT performed with radiotracers other than FDG, and other functional forms of disease maps.

  8. Competency-Based Teaching in Radiology - Implementation and Evaluation of Interactive Workstation-Based Learning to Apply NKLM-Based Content.

    PubMed

    Koestner, Wolfgang; Otten, Wiebke; Kaireit, Till; Wacker, Frank K; Dettmer, Sabine

    2017-11-01

    Purpose  New teaching formats are required to implement competency-based teaching in radiology teaching. Therefore, we have established and evaluated two practical competency-based radiological courses. Materials and Methods  The courses were held in a multimedia room with 25 computers and a professional DICOM viewer. Students were taught basic image analysis and presented clinical cases with a DICOM viewer under supervision of an instructor using desktop monitoring software. Two courses (elective course and obligatory course) were evaluated by the students (n = 160 and n = 100) and instructors (n = 9) using an anonymized online survey. Results  Courses were evaluated positively by the students and instructors. From the perspective of the students, the courses increased understanding of cross-sectional anatomy (elective/obligatory course: 97 %/95 %) and radiologic findings (97 %/99 %). Furthermore, the course increased the students' interest in radiology (61 %/65 %). The students considered this way of teaching to be relevant to their future occupation (92 % of students in the obligatory course). The higher incidence of teacher-student interaction and the possibility of independent image analysis were rated positively. The majority of instructors did not observe increased distractibility due to the computers (67 %) or notice worse preparation for MC tests (56 %). However, 56 % of instructors reported greater preparation effort. Conclusion  Practical competency-based radiological teaching using a DICOM viewer is a feasible innovative approach with high acceptance among students and instructors. It fosters competency-based learning as proposed by the model curriculum of the German Radiological Society (DRG) and the National Competency-based Catalogue of Learning Objectives for Undergraduate Medical Education (NKLM). Key Points   · Practical competency-based radiological teaching is highly accepted by students and instructors.. · Students report improved understanding of imaging anatomy and radiological findings.. · Interactive case presentation with a DICOM viewer fosters competency-based learning.. Citation Format · Koestner W, Otten W, Kaireit T et al. Competency-Based Teaching in Radiology - Implementation and Evaluation of Interactive Workstation-Based Learning to Apply NKLM-Based Content. Fortschr Röntgenstr 2017; 189: 1076 - 1085. © Georg Thieme Verlag KG Stuttgart · New York.

  9. [New international networks in radiology graduate and continuing education: www.eurorad.org--a EAR Project for online publication of radiological data].

    PubMed

    Vorwerk, D

    2002-02-01

    Eurorad (www.eurorad.org) is a joint project of EAR and has support of 27 national and 8 subspeciality radiology societies. Eurorad is the first noncommercial radiological publication that is exclusively based on the internet as a communication line with all steps of submission, reviewing and publication being performed online. Eurorad wants to build up a huge and exhaustive case file of diagnostic and interventional radiology. Like all scientific publications, Eurorad bases on an editor in chief and 13 section editors who are responsible for organizing each section of Eurorad. Each section has a number of peer reviewer with an overall total of more than 100. For submission and publication, all cases are structured in the same manner with case report, method and discussion. For the time being, Eurorad hosts 779 cases, of whom 346 are free available on the net. The actual rejection rate is 4.5%, other cases are under review.

  10. Predicting Airport Screening Officers' Visual Search Competency With a Rapid Assessment.

    PubMed

    Mitroff, Stephen R; Ericson, Justin M; Sharpe, Benjamin

    2018-03-01

    Objective The study's objective was to assess a new personnel selection and assessment tool for aviation security screeners. A mobile app was modified to create a tool, and the question was whether it could predict professional screeners' on-job performance. Background A variety of professions (airport security, radiology, the military, etc.) rely on visual search performance-being able to detect targets. Given the importance of such professions, it is necessary to maximize performance, and one means to do so is to select individuals who excel at visual search. A critical question is whether it is possible to predict search competency within a professional search environment. Method Professional searchers from the USA Transportation Security Administration (TSA) completed a rapid assessment on a tablet-based X-ray simulator (XRAY Screener, derived from the mobile technology app Airport Scanner; Kedlin Company). The assessment contained 72 trials that were simulated X-ray images of bags. Participants searched for prohibited items and tapped on them with their finger. Results Performance on the assessment significantly related to on-job performance measures for the TSA officers such that those who were better XRAY Screener performers were both more accurate and faster at the actual airport checkpoint. Conclusion XRAY Screener successfully predicted on-job performance for professional aviation security officers. While questions remain about the underlying cognitive mechanisms, this quick assessment was found to significantly predict on-job success for a task that relies on visual search performance. Application It may be possible to quickly assess an individual's visual search competency, which could help organizations select new hires and assess their current workforce.

  11. Physiology Laboratories Quantifying Gas Exchange in Health and Disease.

    ERIC Educational Resources Information Center

    Olson, L. E.

    1985-01-01

    Describes two quantitatively-oriented physiology laboratories for veterinary students. The laboratory exercises incorporate the procedures of radiology and physical examination with measurement of pulmonary function. Specific laboratory objectives, procedures and equipment needed for diagnoses of the pathologies are listed. (ML)

  12. Towards 3D printed multifunctional immobilization for proton therapy: Initial materials characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michiels, Steven, E-mail: michiels.steven@kuleuven

    Purpose: 3D printing technology is investigated for the purpose of patient immobilization during proton therapy. It potentially enables a merge of patient immobilization, bolus range shifting, and other functions into one single patient-specific structure. In this first step, a set of 3D printed materials is characterized in detail, in terms of structural and radiological properties, elemental composition, directional dependence, and structural changes induced by radiation damage. These data will serve as inputs for the design of 3D printed immobilization structure prototypes. Methods: Using four different 3D printing techniques, in total eight materials were subjected to testing. Samples with a nominalmore » dimension of 20 × 20 × 80 mm{sup 3} were 3D printed. The geometrical printing accuracy of each test sample was measured with a dial gage. To assess the mechanical response of the samples, standardized compression tests were performed to determine the Young’s modulus. To investigate the effect of radiation on the mechanical response, the mechanical tests were performed both prior and after the administration of clinically relevant dose levels (70 Gy), multiplied with a safety factor of 1.4. Dual energy computed tomography (DECT) methods were used to calculate the relative electron density to water ρ{sub e}, the effective atomic number Z{sub eff}, and the proton stopping power ratio (SPR) to water SPR. In order to validate the DECT based calculation of radiological properties, beam measurements were performed on the 3D printed samples as well. Photon irradiations were performed to measure the photon linear attenuation coefficients, while proton irradiations were performed to measure the proton range shift of the samples. The directional dependence of these properties was investigated by performing the irradiations for different orientations of the samples. Results: The printed test objects showed reduced geometric printing accuracy for 2 materials (deviation > 0.25 mm). Compression tests yielded Young’s moduli ranging from 0.6 to 2940 MPa. No deterioration in the mechanical response was observed after exposure of the samples to 100 Gy in a therapeutic MV photon beam. The DECT-based characterization yielded Z{sub eff} ranging from 5.91 to 10.43. The SPR and ρ{sub e} both ranged from 0.6 to 1.22. The measured photon attenuation coefficients at clinical energies scaled linearly with ρ{sub e}. Good agreement was seen between the DECT estimated SPR and the measured range shift, except for the higher Z{sub eff}. As opposed to the photon attenuation, the proton range shifting appeared to be printing orientation dependent for certain materials. Conclusions: In this study, the first step toward 3D printed, multifunctional immobilization was performed, by going through a candidate clinical workflow for the first time: from the material printing to DECT characterization with a verification through beam measurements. Besides a proof of concept for beam modification, the mechanical response of printed materials was also investigated to assess their capabilities for positioning functionality. For the studied set of printing techniques and materials, a wide variety of mechanical and radiological properties can be selected from for the intended purpose. Moreover the elaborated hybrid DECT methods aid in performing in-house quality assurance of 3D printed components, as these methods enable the estimation of the radiological properties relevant for use in radiation therapy.« less

  13. Radiological performance assessment for the E-Area Vaults Disposal Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, J.R.

    This report is the first revision to ``Radiological Performance Assessment for the E-Area Vaults Disposal Facility, Revision 0'', which was issued in April 1994 and received conditional DOE approval in September 1994. The title of this report has been changed to conform to the current name of the facility. The revision incorporates improved groundwater modeling methodology, which includes a large data base of site specific geotechnical data, and special Analyses on disposal of cement-based wasteforms and naval wastes, issued after publication of Revision 0.

  14. Development of a statewide hospital plan for radiologic emergencies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dainiak, Nicholas; Delli Carpini, Domenico; Bohan, Michael

    Although general guidelines have been developed for triage of victims in the field and for hospitals to plan for a radiologic event, specific information for clinicians and administrators is not available for guidance in efficient management of radiation victims during their early encounter in the hospital. A consensus document was developed by staff members of four Connecticut hospitals, two institutions of higher learning, and the State of Connecticut Department of Environmental Protection and Office of Emergency Preparedness, with assistance of the American Society for Therapeutic Radiology and Oncology. The objective was to write a practical manual for clinicians (including radiationmore » oncologists, emergency room physicians, and nursing staff), hospital administrators, radiation safety officers, and other individuals knowledgeable in radiation monitoring that would be useful for evaluation and management of radiation injury. The rationale for and process by which the radiation response plan was developed and implemented in the State of Connecticut are reviewed. Hospital admission pathways are described, based on classification of victims as exposed, contaminated, and/or physically injured. This manual will be of value to those involved in planning the health care response to a radiologic event.« less

  15. [Radiology in managed care environment: opportunities for cost savings in an HMO].

    PubMed

    Schmidt, C; Mohr, A; Möller, J; Levin-Scherz, J; Heller, M

    2003-09-01

    A large regional health plan in the Northeastern United States noted that its radiology costs were increasing more than it anticipated in its pricing, and noted further that other similar health plans in markets with high managed care penetration had significantly lower expenses for radiology services. This study describes the potential areas of improvement and managed care techniques that were implemented to reduce costs and reform processes. We performed an in-depth analysis of financial data, claims logic, contracting with provider units and conducted interviews with employees, to identify potential areas of improvement and cost reduction. A detailed market analysis of the environment, competitors and vendors was accompanied by extensive literature, Internet and Medline search for comparable projects. All data were docu-mented in Microsoft Excel(R) and analyzed by non-parametric tests using SPSS(R) 8.0 (Statistical Package for the Social Sciences) for Windows(R). The main factors driving the cost increases in radiology were divided into those internal or external to the HMO. Among the internal factors, the claims logic was allowing overpayment due to limitations of the IT system. Risk arrangements between insurer and provider units (PU) as well as the extent of provider unit management and administration showed a significant correlation with financial performance in terms of variance from budget. Among the external factors, shared risk arrangements between HMO and provider unit were associated with more efficient radiology utilization and overall improvement in financial performance. PU with full-time management had significantly less variance from their budget than those without. Finally, physicians with imaging equipment in their offices ordered up to 4 to 5 times more imaging procedures than physicians who did not perform imaging studies themselves. We identified initiatives with estimated potential savings of approximately $ 5.5 million. Some of these initiatives are similar to the reforms to reduce cost and improve quality that are already implemented or proposed within the German healthcare system.

  16. [eLearning-radiology.com--sustainability for quality assurance].

    PubMed

    Ketelsen, D; Talanow, R; Uder, M; Grunewald, M

    2009-04-01

    The aim of the study was to analyze the availability of published radiological e-learning tools and to establish a solution for quality assurance. Substantial pubmed research was performed to identify radiological e-learning tools. 181 e-learning programs were selected. As examples two databases expanding their programs with external links, Compare (n = 435 external links) and TNT-Radiology (n = 1078 external links), were evaluated. A concept for quality assurance was developed by an international taskforce. At the time of assessment, 56.4 % (102 / 181) of the investigated e-learning tools were accessible at their original URL. A subgroup analysis of programs published 5 to 8 years ago showed significantly inferior availability to programs published 3 to 5 years ago (p < 0.01). The analysis of external links showed 49.2 % and 61.0 % accessible links for the programs Compare (published 2003) and TNT-Radiology (published 2006), respectively. As a consequence, the domain www.eLearning-radiology.com was developed by the taskforce and published online. This tool allows authors to present their programs and users to evaluate the e-learning tools depending on several criteria in order to remove inoperable links and to obtain information about the complexity and quality of the e-learning tools. More than 50 % of investigated radiological e-learning tools on the Internet were not accessible after a period of 5 to 8 years. As a consequence, an independent, international tool for quality assurance was designed and published online under www.eLearning-radiology.com .

  17. Auditor recommendations resulting from three clinical audit rounds in Finnish radiology units.

    PubMed

    Miettunen, Kirsi; Metsälä, Eija

    2017-06-01

    Background The purpose of clinical audits performed in radiology units is to reduce the radiation dose of patients and staff and to implement evidence-based best practices. Purpose To describe auditor recommendations in three Finnish clinical audit rounds performed in 2002-2014, and to determine if auditor recommendations have had any impact on improving medical imaging practice. Material and Methods The retrospective observational study was performed in radiology units holding a radiation safety license issued by the Finnish Radiation and Nuclear Safety Authority. The data comprised a systematic sample (n = 120) of auditor reports produced in three auditing rounds in these units during the years 2002-2014. The data were analyzed by descriptive methods and by using the Friedman two-way ANOVA test. Results The number of auditor recommendations given varied between clinical audit rounds and according to the type of imaging unit, as well as according to calculation method. Proportionally, the most recommendations in all three clinical audit rounds were given about defining and using quality assurance functions and about guidelines and practices for carrying out procedures involving radiation exposure. Demanding radiology units improved their practices more than basic imaging units towards the third round. Conclusion Auditor recommendations help to address the deficiencies in imaging practices. There is a need to develop uniform guidelines and to provide tutoring for clinical auditors in order to produce comparable clinical audit results.

  18. ACR-SPR-STR Practice Parameter for the Performance of Cardiac Positron Emission Tomography - Computed Tomography (PET/CT) Imaging.

    PubMed

    Subramaniam, Rathan M; Janowitz, Warren R; Johnson, Geoffrey B; Lodge, Martin A; Parisi, Marguerite T; Ferguson, Mark R; Hellinger, Jeffrey C; Gladish, Gregory W; Gupta, Narainder K

    2017-12-01

    This clinical practice parameter has been developed collaboratively by the American College of Radiology (ACR), the Society for Pediatric Radiology (SPR), and the Society of Thoracic Radiology (STR). This document is intended to act as a guide for physicians performing and interpreting positron emission tomography-computed tomography (PET/CT) of cardiac diseases in adults and children. The primary value of cardiac PET/CT imaging include evaluation of perfusion, function, viability, inflammation, anatomy, and risk stratification for cardiac-related events such as myocardial infarction and death. Optimum utility of cardiac PET/CT is achieved when images are interpreted in conjunction with clinical information and laboratory data. Measurement of myocardial blood flow, coronary flow reserve and detection of balanced ischemia are significant advantages of cardiac PET perfusion studies. Increasingly cardiac PET/CT is used in diagnosis and treatment response assessment for cardiac sarcoidosis.

  19. Trainees May Add Value to Patient Care by Decreasing Addendum Utilization in Radiology Reports.

    PubMed

    Balthazar, Patricia; Konstantopoulos, Christina; Wick, Carson A; DeSimone, Ariadne K; Tridandapani, Srini; Simoneaux, Stephen; Applegate, Kimberly E

    2017-11-01

    The purpose of this study was to evaluate the impact of trainee involvement and other factors on addendum rates in radiology reports. This retrospective study was performed in a tertiary care pediatric hospital. From the institutional radiology data repository, we extracted all radiology reports from January 1 to June 30, 2016, as well as trainee (resident or fellow) involvement, imaging modality, patient setting (emergency, inpatient, or outpatient), order status (routine vs immediate), time of interpretation (regular work hours vs off-hours), radiologist's years of experience, and sex. We grouped imaging modalities as advanced (CT, MRI, and PET) or nonadvanced (any modality that was not CT, MRI, or PET) and radiologist experience level as ≤ 20 years or > 20 years. Our outcome measure was the rate of addenda in radiology reports. Statistical analysis was performed using multivariate logistic regression. From 129,033 reports finalized during the study period, 418 (0.3%) had addenda. Reports generated without trainees were 12 times more likely than reports with trainee involvement to have addenda (odds ratio [OR] = 12.2, p < 0.001). Advanced imaging studies were more likely than nonadvanced studies to be associated with addendum use (OR = 4.7, p < 0.001). Reports generated for patients in emergency or outpatient settings had a slightly higher likelihood of addendum use than those in an inpatient setting (OR = 1.5, p = 0.04; and OR = 1.3, p = 0.04, respectively). Routine orders had a slightly higher likelihood of addendum use compared with immediate orders (OR = 1.3, p = 0.01). We found no difference in addendum use by radiologist's sex, radiologist's years of experience, emergency versus outpatient setting, or time of interpretation. Trainees may add value to patient care by decreasing addendum rates in radiology reports.

  20. Performance of lung ultrasonography for the diagnosis of communityacquired pneumonia in hospitalized children.

    PubMed

    Man, Sorin Claudiu; Fufezan, Otilia; Sas, Valentina; Schnell, Cristina

    2017-05-10

    The objective of the study was to assess the performance of lung ultrasonography (LUS) as compared to chest radiography and the clinical criteria for the diagnosis of pneumonia in children. This was a retrospective study in which data were collected from medical files of 81 children admitted with a clinical suspicion of pneumonia in which both an LUS and a chest radiograph during the hospitalization were performed. Reference standard used for the diagnosis of pneumonia were chest radiographs (consolidation, parenchymal infiltrates, and interstitial infiltrate) and clinical criteria. LUSfindings were reported as normal, parenchymal consolidations and pleural effusions. Radiological pneumonia was reported in 72 of the 81 patients (88.9%). LUS identified parenchymal consolidations in 62 cases. LUS correctly identified radiological pneumonia with a sensitivity of 79.2% and a specificity of 44.4%. The positive predictive value (PPV) was 91.9% and the negative predictive value (NPV) was 21.0%. When clinical criteria were used as reference standard, the sensitivity, specificity, PPV and NPV of correctly identifying clinical pneumonia cases by LUS (only consolidations) were 80.0%, 66.7%, 96.8% and 21.0%. When indicative for the presence of pneumonia either the ultrasound consolidation or the ultrasound detected pleural effusion were considered when the sensitivity, PPV and NPV increased to 96.0% (95%CI: 88.8-99.2), 97.3% (95%CI: 92.0-99.1), and 57.1% (95%CI: 27.7-82.2), respectively. In our opinion, our findings together withprevious ones available in the literature recommend LUS as a valuable investigation for the diagnosis of community-acquiredpneumonia in children.

  1. Closure Report for Corrective Action Unit 412: Clean Slate I Plutonium Dispersion (TTR) Tonopah Test Range, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, Patrick

    This Closure Report (CR) presents information supporting the clean closure of Corrective Action Unit (CAU) 412: Clean Slate I Plutonium Dispersion (TTR), located on the Tonopah Test Range, Nevada. CAU 412 consists of a release of radionuclides to the surrounding soil from a storage–transportation test conducted on May 25, 1963. Corrective action investigation (CAI) activities were performed in April and May 2015, as set forth in the Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 412: Clean Slate I Plutonium Dispersion (TTR), Tonopah Test Range, Nevada; and in accordance with the Soils Activity Quality Assurance Plan. Themore » purpose of the CAI was to fulfill data needs as defined during the data quality objectives process. The CAU 412 dataset of investigation results was evaluated based on a data quality assessment. This assessment demonstrated the dataset is complete and acceptable for use in fulfilling the data needs identified by the data quality objectives process. This CR provides documentation and justification for the clean closure of CAU 412 under the FFACO without further corrective action. This justification is based on historical knowledge of the site, previous site investigations, implementation of the 1997 interim corrective action, and the results of the CAI. The corrective action of clean closure was confirmed as appropriate for closure of CAU 412 based on achievement of the following closure objectives: Radiological contamination at the site is less than the final action level using the ground troops exposure scenario (i.e., the radiological dose is less than the final action level): Removable alpha contamination is less than the high contamination area criterion: No potential source material is present at the site, and any impacted soil associated with potential source material has been removed so that remaining soil contains contaminants at concentrations less than the final action levels: and There is sufficient information to characterize investigation and remediation waste for disposal.« less

  2. Evaluating and Measuring the Return on Investment of an Emergency Center Health Care Professional Picture Archiving and Communication Systems Training Program

    ERIC Educational Resources Information Center

    Roelandt, James P.

    2012-01-01

    Picture archiving and communication system (PACS) workflow directly affects the quality of emergency patient care through radiology exam turn-around times and the speed of delivery of diagnostic radiology results. This study was a mixed methods training and performance improvement study that evaluated the effectiveness and value of a hospital…

  3. Placement of central venous port catheters and peripherally inserted central catheters in the routine clinical setting of a radiology department: analysis of costs and intervention duration learning curve.

    PubMed

    Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H

    2017-12-01

    Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.

  4. UWGSP6: a diagnostic radiology workstation of the future

    NASA Astrophysics Data System (ADS)

    Milton, Stuart W.; Han, Sang; Choi, Hyung-Sik; Kim, Yongmin

    1993-06-01

    The Univ. of Washington's Image Computing Systems Lab. (ICSL) has been involved in research into the development of a series of PACS workstations since the middle 1980's. The most recent research, a joint UW-IBM project, attempted to create a diagnostic radiology workstation using an IBM RISC System 6000 (RS6000) computer workstation and the X-Window system. While the results are encouraging, there are inherent limitations in the workstation hardware which prevent it from providing an acceptable level of functionality for diagnostic radiology. Realizing the RS6000 workstation's limitations, a parallel effort was initiated to design a workstation, UWGSP6 (Univ. of Washington Graphics System Processor #6), that provides the required functionality. This paper documents the design of UWGSP6, which not only addresses the requirements for a diagnostic radiology workstation in terms of display resolution, response time, etc., but also includes the processing performance necessary to support key functions needed in the implementation of algorithms for computer-aided diagnosis. The paper includes a description of the workstation architecture, and specifically its image processing subsystem. Verification of the design through hardware simulation is then discussed, and finally, performance of selected algorithms based on detailed simulation is provided.

  5. Using Gagne's theory to teach chest X-ray interpretation.

    PubMed

    Belfield, Jane

    2010-03-01

    as a Radiologist providing teaching for medical students and junior doctors, I have spent time devising lesson plans. It is vital to know the aims and objectives prior to teaching sessions in order that the students benefit as much as possible. This article describes a lesson plan for interpretation of a chest X-Ray using a theory described by Robert Gagne. Gagne developed a model of instructional design, which provides information and interaction to enhance the learning process. This model is based on nine instructional events used during a teaching session. These are: gaining attention, informing the learner of the objective, stimulating recall of prior material, presenting the stimulus material, providing learning guidance, eliciting the performance, providing feedback, assessing the performance and enhancing retention and transfer. this article uses the nine points described by Gagne and describes a model of how to teach chest X-ray interpretation. Each of Gagne's points is illustrated with a specific example of how this would fit into the Radiology teaching session. Gagne's theory of instructional design can be adapted depending on the subject being taught. It is useful, both for the teacher and the student, to prepare a lesson plan in advance with knowledge of required aims and objectives. Having run teaching sessions which use Gagne's theory, students have given very positive feedback and as a teacher I found the lesson ran more smoothly. Blackwell Publishing Ltd 2010.

  6. Role of interventional radiology in the management of acute gastrointestinal bleeding

    PubMed Central

    Ramaswamy, Raja S; Choi, Hyung Won; Mouser, Hans C; Narsinh, Kazim H; McCammack, Kevin C; Treesit, Tharintorn; Kinney, Thomas B

    2014-01-01

    Acute gastrointestinal bleeding (GIB) can lead to significant morbidity and mortality without appropriate treatment. There are numerous causes of acute GIB including but not limited to infection, vascular anomalies, inflammatory diseases, trauma, and malignancy. The diagnostic and therapeutic approach of GIB depends on its location, severity, and etiology. The role of interventional radiology becomes vital in patients whose GIB remains resistant to medical and endoscopic treatment. Radiology offers diagnostic imaging studies and endovascular therapeutic interventions that can be performed promptly and effectively with successful outcomes. Computed tomography angiography and nuclear scintigraphy can localize the source of bleeding and provide essential information for the interventional radiologist to guide therapeutic management with endovascular angiography and transcatheter embolization. This review article provides insight into the essential role of Interventional Radiology in the management of acute GIB. PMID:24778770

  7. International Arctic Seas Assessment Project.

    PubMed

    Sjöblom, K L; Salo, A; Bewers, J M; Cooper, J; Dyer, R S; Lynn, N M; Mount, M E; Povinec, P P; Sazykina, T G; Schwarz, J; Scott, E M; Sivintsev, Y V; Tanner, J E; Warden, J M; Woodhead, D

    1999-09-30

    The International Atomic Energy Agency responded to the news that the former Soviet Union had dumped radioactive wastes in the shallow waters of the Arctic Seas, by launching the International Arctic Seas Assessment Project in 1993. The project had two objectives: to assess the risks to human health and to the environment associated with the radioactive wastes dumped in the Kara and Barents Seas; and to examine possible remedial actions related to the dumped wastes and to advise on whether they are necessary and justified. The current radiological situation in the Arctic waters was examined to assess whether there is any evidence for releases from the dumped waste. Potential future releases from the dumped wastes were predicted, concentrating on the high-level waste objects containing the major part of the radionuclide inventory of the wastes. Environmental transport of released radionuclides was modelled and the associated radiological impact on humans and the biota was assessed. The feasibility, costs and benefits of possible remedial measures applied to a selected high-level waste object were examined. Releases from identified dumped objects were found to be small and localised to the immediate vicinity of the dumping sites. Projected future annual doses to members of the public in typical local population groups were very small, less than 1 microSv--corresponding to a trivial risk. Projected future doses to a hypothetical group of military personnel patrolling the foreshore of the fjords in which wastes have been dumped were higher, up to 4 mSv/year, which still is of the same order as the average annual natural background dose. Moreover, since any of the proposed remedial actions were estimated to cost several million US$ to implement, remediation was not considered justified on the basis of potentially removing a collective dose of 10 man Sv. Doses calculated to marine fauna were insignificant, orders of magnitude below those at which detrimental effects on fauna populations might be expected to occur. Remediation was thus concluded not to be warranted on radiological grounds.

  8. Correlation between radiological parameters and patient-rated wrist dysfunction following fractures of the distal radius.

    PubMed

    Karnezis, I A; Panagiotopoulos, E; Tyllianakis, M; Megas, P; Lambiris, E

    2005-12-01

    The present study investigates the correlation between radiological parameters of wrist fractures and the clinical outcome expressed by objective clinical parameters and the level of patient-rated wrist dysfunction. Thirty consecutive cases of unstable distal radial fractures treated with closed reduction and percutaneous fixation were prospectively studied for a period of one year. The outcome parameters included objective clinical and radiological parameters and the previously described and validated patient-rated wrist evaluation (PRWE) score. Analysis showed that for unstable (AO classification types 23-A2, -A3, -C1 and -C2) fractures the fracture type affects the range of wrist palmarflexion (p=0.04) and that the presence of postoperative articular 'step-off' affects the range of wrist dorsiflexion and the patient-rated wrist function at the final time of the study (p<0.01 and p=0.02, respectively). It is also shown that permanent radial shortening and loss of the palmar angle were associated with prolonged wrist pain (p<0.01 and p=0.03, respectively). Our finding that residual articular incongruity correlates with persisting loss of wrist dorsiflexion and wrist dysfunction contradicts the view that loss of articular congruity is associated with late development of articular degeneration but not with early wrist dysfunction. Additionally, this study failed to show any association between the fracture type and the functional outcome as rated by the patients.

  9. Optimization of propagation-based x-ray phase-contrast tomography for breast cancer imaging

    NASA Astrophysics Data System (ADS)

    Baran, P.; Pacile, S.; Nesterets, Y. I.; Mayo, S. C.; Dullin, C.; Dreossi, D.; Arfelli, F.; Thompson, D.; Lockie, D.; McCormack, M.; Taba, S. T.; Brun, F.; Pinamonti, M.; Nickson, C.; Hall, C.; Dimmock, M.; Zanconati, F.; Cholewa, M.; Quiney, H.; Brennan, P. C.; Tromba, G.; Gureyev, T. E.

    2017-03-01

    The aim of this study was to optimise the experimental protocol and data analysis for in-vivo breast cancer x-ray imaging. Results are presented of the experiment at the SYRMEP beamline of Elettra Synchrotron using the propagation-based phase-contrast mammographic tomography method, which incorporates not only absorption, but also x-ray phase information. In this study the images of breast tissue samples, of a size corresponding to a full human breast, with radiologically acceptable x-ray doses were obtained, and the degree of improvement of the image quality (from the diagnostic point of view) achievable using propagation-based phase-contrast image acquisition protocols with proper incorporation of x-ray phase retrieval into the reconstruction pipeline was investigated. Parameters such as the x-ray energy, sample-to-detector distance and data processing methods were tested, evaluated and optimized with respect to the estimated diagnostic value using a mastectomy sample with a malignant lesion. The results of quantitative evaluation of images were obtained by means of radiological assessment carried out by 13 experienced specialists. A comparative analysis was performed between the x-ray and the histological images of the specimen. The results of the analysis indicate that, within the investigated range of parameters, both the objective image quality characteristics and the subjective radiological scores of propagation-based phase-contrast images of breast tissues monotonically increase with the strength of phase contrast which in turn is directly proportional to the product of the radiation wavelength and the sample-to-detector distance. The outcomes of this study serve to define the practical imaging conditions and the CT reconstruction procedures appropriate for low-dose phase-contrast mammographic imaging of live patients at specially designed synchrotron beamlines.

  10. Total knee arthroplasty after failed high tibial osteotomy: a systematic review of open versus closed wedge osteotomy.

    PubMed

    Han, Jae Hwi; Yang, Jae-Hyuk; Bhandare, Nikhl N; Suh, Dong Won; Lee, Jong Seong; Chang, Yong Suk; Yeom, Ji Woong; Nha, Kyung Wook

    2016-08-01

    Medial opening wedge high tibial osteotomy (HTO) has become increasingly popular as an alternative to lateral closing wedge osteotomy for the treatment of medial compartment knee osteoarthritis with varus deformity. The present systematic review was conducted to provide an objective analysis of total knee arthroplasty (TKA) outcomes following previous knee osteotomy (medial opening wedge vs. lateral closing wedge). A literature search of online databases (MEDLINE, EMBASE, Cochrane Library database) was made, in addition to manual search of major orthopaedic journals. The methodological quality of each of the studies was assessed on the Newcastle-Ottawa Scale and Effective Practice and Organization of Care. A total of ten studies were included in the review. There were eight studies with Level IV and two studies with Level III evidence. Eight studies reported clinical and radiologic scores. Comparative studies between TKA following medial opening and lateral closing wedge HTO did not demonstrate statistically significant clinical and radiologic differences. The revision rates were similar. However, more technical issues during TKA surgery after lateral closing wedge HTO were mentioned than the medial open wedge group. The quadriceps snip, tibial tubercle osteotomy, and lateral soft tissue release were more frequently needed in the lateral closing wedge HTO group. In addition, because of loss of proximal tibia bone geometry in the lateral closing wedge HTO group, concerns such as tibia stem impingement in the lateral tibial cortex was noted. The present systematic review suggests that TKA after medial opening and lateral closing wedge HTO showed similar performance. Clinical and radiologic outcome including revision rates did not statistically differ from included studies. However, there are more surgical technical concerns in TKA conversion from lateral closing wedge HTO than from the medial opening wedge HTO group. IV.

  11. The Spectrum of Central Nervous System Infections in an Adult Referral Hospital in Hanoi, Vietnam

    PubMed Central

    Taylor, Walter R.; Nguyen, Kinh; Nguyen, Duc; Nguyen, Huyen; Horby, Peter; Nguyen, Ha L.; Lien, Trinh; Tran, Giang; Tran, Ninh; Nguyen, Ha M.; Nguyen, Thai; Nguyen, Ha H.; Nguyen, Thanh; Tran, Giap; Farrar, Jeremy; de Jong, Menno; Schultsz, Constance; Tran, Huong; Nguyen, Diep; Vu, Bich; Le, Hoa; Dao, Trinh; Nguyen, Trung; Wertheim, Heiman

    2012-01-01

    Objectives To determine prospectively the causative pathogens of central nervous system (CNS) infections in patients admitted to a tertiary referral hospital in Hanoi, Vietnam. Methods From May 2007 to December 2008, cerebrospinal fluid (CSF) samples from 352 adults with suspected meningitis or encephalitis underwent routine testing, staining (Gram, Ziehl-Nielsen, India ink), bacterial culture and polymerase chain reaction targeting Neisseria meningitidis, Streptococcus pneumoniae, S. suis, Haemophilus influenzae type b, Herpes simplex virus (HSV), Varicella Zoster virus (VZV), enterovirus, and 16S ribosomal RNA. Blood cultures and clinically indicated radiology were also performed. Patients were classified as having confirmed or suspected bacterial (BM), tuberculous (TBM), cryptococcal (CRM), eosinophilic (EOM) meningitis, aseptic encephalitis/meningitis (AEM), neurocysticercosis and others. Results 352 (male: 66%) patients were recruited: median age 34 years (range 13–85). 95/352 (27.3%) diagnoses were laboratory confirmed and one by cranial radiology: BM (n = 62), TBM (n = 9), AEM (n = 19), CRM (n = 5), and neurocysticercosis (n = 1, cranial radiology). S. suis predominated as the cause of BM [48/62 (77.4%)]; Listeria monocytogenese (n = 1), S. pasteurianus (n = 1) and N. meningitidis (n = 2) were infrequent. AEM viruses were: HSV (n = 12), VZV (n = 5) and enterovirus (n = 2). 5 patients had EOM. Of 262/352 (74.4%) patients with full clinical data, 209 (79.8%) were hospital referrals and 186 (71%) had been on antimicrobials. 21 (8%) patients died: TBM (15.2%), AEM (10%), and BM (2.8%). Conclusions Most infections lacked microbiological confirmation. S. suis was the most common cause of BM in this setting. Improved diagnostics are needed for meningoencephalitic syndromes to inform treatment and prevention strategies. PMID:22952590

  12. Experimental system for measurement of radiologists' performance by visual search task.

    PubMed

    Maeda, Eriko; Yoshikawa, Takeharu; Nakashima, Ryoichi; Kobayashi, Kazufumi; Yokosawa, Kazuhiko; Hayashi, Naoto; Masutani, Yoshitaka; Yoshioka, Naoki; Akahane, Masaaki; Ohtomo, Kuni

    2013-01-01

    Detective performance of radiologists for "obvious" targets should be evaluated by visual search task instead of ROC analysis, but visual task have not been applied to radiology studies. The aim of this study was to set up an environment that allows visual search task in radiology, to evaluate its feasibility, and to preliminarily investigate the effect of career on the performance. In a darkroom, ten radiologists were asked to answer the type of lesion by pressing buttons, when images without lesions, with bulla, ground-glass nodule, and solid nodule were randomly presented on a display. Differences in accuracy and reaction times depending on board certification were investigated. The visual search task was successfully and feasibly performed. Radiologists were found to have high sensitivity, specificity, positive predictive values and negative predictive values in non-board and board groups. Reaction time was under 1 second for all target types in both groups. Board radiologists were significantly faster in answering for bulla, but there were no significant differences for other targets and values. We developed an experimental system that allows visual search experiment in radiology. Reaction time for detection of bulla was shortened with experience.

  13. Role of follow-up endoscopic examination in treatment response assessment for patients with gastric diffuse large B cell lymphoma.

    PubMed

    Yoon, Seung Bae; Lee, In Seok; Lee, Ha Ni; Kim, Eunyoung; Kim, Woohyeon; Lee, Han Hee; Lee, Bo-In; Choi, Myung-Gyu; Jung, Seung Eun; Choi, Byung Ock; Park, Gyeong Sin; Cho, Seok-Goo

    2016-09-01

    According to lymphoma guidelines, gastric diffuse large B cell lymphoma (DLBCL) patients should undergo regular computed tomography (CT) and/or positron emission tomography (PET) examinations to assess treatment response. Endoscopic examinations are not indicated in the guidelines. The aim of this study was to investigate the utility of endoscopic examinations during and after treatment for DLBCL. We reviewed the patients diagnosed with gastric DLBCL at Seoul St. Mary's Hospital. All patients underwent endoscopy and radiologic examinations at every follow-up appointment. Radiologic response was defined according to World Health Organization criteria and endoscopic response was determined based on the Groupe d'Etude des Lymphomes de l'Adult grading system that is widely used in post-treatment evaluation of gastric MALT lymphoma. Forty-five patients were analyzed. Within a median follow-up period of 34 months, 35 patients achieved both radiologic and endoscopic complete remission (CR). The median times to endoscopic and radiologic CR were not significantly different (21 versus 16 weeks, p = 0.118). However, in 25 patients with stage I disease, endoscopic CR [median (range), 20 (11-36)] was achieved later than radiologic CR [median (range), 13 (8-36)] (p = 0.027). Among 40 patients who achieved radiologic CR, 35 patients who also achieved endoscopic CR maintained remission during the follow-up. Two of the five patients who achieved radiologic CR without endoscopic CR experienced recurrence. In gastric DLBCL patients, endoscopic response does not always correlate with radiologic response and might predict disease recurrence. We suggest that follow-up endoscopic examination with biopsy should be performed in addition to radiologic examination.

  14. Remote Handled WIPP Canisters at Los Alamos National Laboratory Characterized for Retrieval

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Griffin, J.; Gonzales, W.

    2007-07-01

    The Los Alamos National Laboratory (LANL) is pursuing retrieval, transportation, and disposal of 16 remote handled transuranic waste canisters stored below ground in shafts since 1994. These canisters were retrievably stored in the shafts to await Nuclear Regulatory Commission certification of the Model Number RH-TRU 72B transportation cask and authorization of the Waste Isolation Pilot Plant (WIPP) to accept the canisters for disposal. Retrieval planning included radiological characterization and visual inspection of the canisters to confirm historical records, verify container integrity, determine proper personnel protection for the retrieval operations, provide radiological dose and exposure rate data for retrieval operations, andmore » to provide exterior radiological contamination data. The radiological characterization and visual inspection of the canisters was performed in May 2006. The effort required the development of remote techniques and equipment due to the potential for personnel exposure to radiological doses approaching 300 R/hr. Innovations included the use of two nested 1.5 meter (m) (5-feet [ft]) long concrete culvert pipes (1.1-m [42 inch (in.)] and 1.5-m [60-in] diameter, respectively) as radiological shielding and collapsible electrostatic dusting wands to collect radiological swipe samples from the annular space between the canister and shaft wall. Visual inspection indicated that the canisters are in good condition with little or no rust, the welded seams are intact, and ten of the canisters include hydrogen gas sampling equipment on the pintle that will have to be removed prior to retrieval. The visual inspection also provided six canister identification numbers that matched historical storage records. The exterior radiological data indicated alpha and beta contamination below LANL release criteria and radiological dose and exposure rates lower than expected based upon historical data and modeling of the canister contents. (authors)« less

  15. Mixed methods study on the use of and attitudes towards safety checklists in interventional radiology.

    PubMed

    Munn, Zachary; Giles, Kristy; Aromataris, Edoardo; Deakin, Anita; Schultz, Timothy; Mandel, Catherine; Peters, Micah Dj; Maddern, Guy; Pearson, Alan; Runciman, William

    2018-02-01

    The use of safety checklists in interventional radiology is an intervention aimed at reducing mortality and morbidity. Currently there is little known about their practical use in Australian radiology departments. The primary aim of this mixed methods study was to evaluate how safety checklists (SC) are used and completed in radiology departments within Australian hospitals, and attitudes towards their use as described by Australian radiologists. A mixed methods approach employing both quantitative and qualitative techniques was used for this study. Direct observations of checklist use during radiological procedures were performed to determine compliance. Medical records were also audited to investigate whether there was any discrepancy between practice (actual care measured by direct observation) and documentation (documented care measured by an audit of records). A focus group with Australian radiologists was conducted to determine attitudes towards the use of checklists. Among the four participating radiology departments, overall observed mean completion of the components of the checklist was 38%. The checklist items most commonly observed to be addressed by the operating theatre staff as noted during observations were correct patient (80%) and procedure (60%). Findings from the direct observations conflicted with the medical record audit, where there was a higher percentage of completion (64% completion) in comparison to the 38% observed. The focus group participants spoke of barriers to the use of checklists, including the culture of radiology departments. This is the first study of safety checklist use in radiology within Australia. Overall completion was low across the sites included in this study. Compliance data collected from observations differed markedly from reported compliance in medical records. There remain significant barriers to the proper use of safety checklists in Australian radiology departments. © 2017 The Royal Australian and New Zealand College of Radiologists.

  16. Developing an automated database for monitoring ultrasound- and computed tomography-guided procedure complications and diagnostic yield.

    PubMed

    Itri, Jason N; Jones, Lisa P; Kim, Woojin; Boonn, William W; Kolansky, Ana S; Hilton, Susan; Zafar, Hanna M

    2014-04-01

    Monitoring complications and diagnostic yield for image-guided procedures is an important component of maintaining high quality patient care promoted by professional societies in radiology and accreditation organizations such as the American College of Radiology (ACR) and Joint Commission. These outcome metrics can be used as part of a comprehensive quality assurance/quality improvement program to reduce variation in clinical practice, provide opportunities to engage in practice quality improvement, and contribute to developing national benchmarks and standards. The purpose of this article is to describe the development and successful implementation of an automated web-based software application to monitor procedural outcomes for US- and CT-guided procedures in an academic radiology department. The open source tools PHP: Hypertext Preprocessor (PHP) and MySQL were used to extract relevant procedural information from the Radiology Information System (RIS), auto-populate the procedure log database, and develop a user interface that generates real-time reports of complication rates and diagnostic yield by site and by operator. Utilizing structured radiology report templates resulted in significantly improved accuracy of information auto-populated from radiology reports, as well as greater compliance with manual data entry. An automated web-based procedure log database is an effective tool to reliably track complication rates and diagnostic yield for US- and CT-guided procedures performed in a radiology department.

  17. Potential time savings to radiology department personnel in a PACS-based environment

    NASA Astrophysics Data System (ADS)

    Saarinen, Allan O.; Wilson, M. C.; Iverson, Scott C.; Loop, John W.

    1990-08-01

    A purported benefit of digital imaging and archiving of radiographic procedures is the presumption of time savings to radiologists, radiology technologists, and radiology departmentpersonnel involved with processingfilms and managing theflimfile room. As part of the University of Washington's evaluation of Picture Archiving and Communication Systems (PACS)for the U.S. Army Medical Research and Development Command, a study was performed which evaluated the current operationalpractices of the film-based radiology department at the University of Washington Medical Center (UWMC). Industrial engineering time and motion studies were conducted to document the length of time requiredforfilm processing in various modalities, the proportion of the total exam time usedforfilm processing, the amount of time radiologists spent searchingfor and looking at images, and the amount of time file room personnel spent collating reports, making loans, updatingfilm jacket information, and purging files. This evaluation showed that better than one-half of the tasks in the file room may be eliminated with PACS and radiologists may save easily 10 percent of the time they spend reading films by no longer having to searchforfilms. Radiology technologists may also save as much as 10 percent of their time with PACS, although this estimate is subject to significant patient mix aberrations and measurement error. Given that the UWMC radiology department operates efficiently, similar improvements are forecast for other radiology departments and larger improvements areforecastfor less efficient departments.

  18. The American Board of Radiology Maintenance of Certification (MOC) Program in Radiologic Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, Stephen R.; Hendee, William R.; Paliwal, Bhudatt R.

    2005-01-01

    Maintenance of Certification (MOC) recognizes that in addition to medical knowledge, several essential elements involved in delivering quality care must be developed and maintained throughout one's career. The MOC process is designed to facilitate and document the professional development of each diplomate of The American Board of Radiology (ABR) through its focus on the essential elements of quality care in Diagnostic Radiology and its subspecialties, and in the specialties of Radiation Oncology and Radiologic Physics. The initial elements of the ABR-MOC have been developed in accord with guidelines of The American Board of Medical Specialties. All diplomates with a ten-year,more » time-limited primary certificate in Diagnostic Radiologic Physics, Therapeutic Radiologic Physics, or Medical Nuclear Physics who wish to maintain certification must successfully complete the requirements of the appropriate ABR-MOC program for their specialty. Holders of multiple certificates must meet ABR-MOC requirements specific to the certificates held. Diplomates with lifelong certificates are not required to participate in the MOC, but are strongly encouraged to do so. MOC is based on documentation of individual participation in the four components of MOC: (1) professional standing, (2) lifelong learning and self-assessment, (3) cognitive expertise, and (4) performance in practice. Within these components, MOC addresses six competencies: medical knowledge, patient care, interpersonal and communication skills, professionalism, practice-based learning and improvement, and systems-based practice.« less

  19. Value of audits in breast cancer screening quality assurance programmes.

    PubMed

    Geertse, Tanya D; Holland, Roland; Timmers, Janine M H; Paap, Ellen; Pijnappel, Ruud M; Broeders, Mireille J M; den Heeten, Gerard J

    2015-11-01

    Our aim was to retrospectively evaluate the results of all audits performed in the past and to assess their value in the quality assurance of the Dutch breast cancer screening programme. The audit team of the Dutch Reference Centre for Screening (LRCB) conducts triennial audits of all 17 reading units. During audits, screening outcomes like recall rates and detection rates are assessed and a radiological review is performed. This study investigates and compares the results of four audit series: 1996-2000, 2001-2005, 2003-2007 and 2010-2013. The analysis shows increased recall rates (from 0.66%, 1.07%, 1.22% to 1.58%), increased detection rates (from 3.3, 4.5, 4.8 to 5.4 per 1000) and increased sensitivity (from 64.5%, 68.7%, 70.5% to 71.6%), over the four audit series. The percentage of 'missed cancers' among interval cancers and advanced screen-detected cancers did not change (p = 0.4). Our audits not only provide an opportunity for assessing screening outcomes, but also provide moments of self-reflection with peers. For radiologists, an accurate understanding of their performance is essential to identify points of improvement. We therefore recommend a radiological review of screening examinations and immediate feedback as part of an audit. • Radiological review and immediate feedback are recommended as part of an audit. • For breast screening radiologists, audits provide moments of self-reflection with peers. • Radiological review of screening examinations provides insights in recall behaviour. • Accurate understanding of radiologists' performance is essential to identify points of improvement.

  20. Evaluation of clinically significant adverse events in patients discharged from a tertiary-care emergency department in Taiwan

    PubMed Central

    Wang, Lee-Min; How, Chorng-Kuang; Yang, Ming-Chin; Su, Syi

    2013-01-01

    Objective To investigate the reasons for the occurrence of clinically significant adverse events (CSAEs) in emergency department-discharged patients through emergency physicians' (EPs) subjective reasoning and senior EPs' objective evaluation. Design This was a combined prospective follow-up and retrospective review of cases of consecutive adult non-traumatic patients who presented to a tertiary-care emergency department in Taiwan between 1 September 2005 and 31 July 2006. Data were extracted from ‘on-duty EPs' subjective reasoning for discharging patients with CSAEs (study group) and without CSAEs (control group)’ and ‘objective evaluation of CSAEs by senior EPs, using clinical evidences such as recording history, physical examinations, laboratory/radiological examinations and observation of inadequacies in the basic management process (such as recording history, physical examinations, laboratory/radiological examinations and observation) as the guide’. Subjective reasons for discharging patients’ improvement of symptoms, and the certainty of safety of the discharge were compared in the two groups using χ2 statistics or t test. Results Of the 20 512 discharged cases, there were 1370 return visits (6.7%, 95% CI 6.3% to 7%) and 165 CSAEs due to physicians' factors (0.82%, 95% CI 0.75% to 0.95%). In comparisons between the study group and the control group, only some components of discharge reasoning showed a significant difference (p<0.001). Inadequacies in the basic management process were the main cause of CSAEs (164/165). Conclusion The authors recommended that EP follow-up of the basic management processes (including history record, physical examination, laboratory and radiological examinations, clinical symptoms/signs and treatment) using clinical evidence as a guideline should be made mandatory. PMID:22433586

  1. A four-alternative forced choice (4AFC) software for observer performance evaluation in radiology

    NASA Astrophysics Data System (ADS)

    Zhang, Guozhi; Cockmartin, Lesley; Bosmans, Hilde

    2016-03-01

    Four-alternative forced choice (4AFC) test is a psychophysical method that can be adopted for observer performance evaluation in radiological studies. While the concept of this method is well established, difficulties to handle large image data, perform unbiased sampling, and keep track of the choice made by the observer have restricted its application in practice. In this work, we propose an easy-to-use software that can help perform 4AFC tests with DICOM images. The software suits for any experimental design that follows the 4AFC approach. It has a powerful image viewing system that favorably simulates the clinical reading environment. The graphical interface allows the observer to adjust various viewing parameters and perform the selection with very simple operations. The sampling process involved in 4AFC as well as the speed and accuracy of the choice made by the observer is precisely monitored in the background and can be easily exported for test analysis. The software has also a defensive mechanism for data management and operation control that minimizes the possibility of mistakes from user during the test. This software can largely facilitate the use of 4AFC approach in radiological observer studies and is expected to have widespread applicability.

  2. Palliative Airway Stenting Performed Under Radiological Guidance and Local Anesthesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Profili, Stefano; Manca, Antonio; Feo, Claudio F.

    2007-02-15

    Purpose. To assess the effectiveness of airway stenting performed exclusively under radiological guidance for the palliation of malignant tracheobronchial strictures. Methods. We report our experience in 16 patients with malignant tracheobronchial stricture treated by insertion of 20 Ultraflex self-expandable metal stents performed under fluoroscopic guidance only. Three patients presented dysphagia grade IV due to esophageal malignant infiltration; they therefore underwent combined airway and esophageal stenting. All the procedures were performed under conscious sedation in the radiological room; average procedure time was around 10 min, but the airway impediment never lasted more than 40 sec. Results. We obtained an overall technicalmore » success in 16 cases (100%) and clinical success in 14 patients (88%). All prostheses were successfully placed without procedural complications. Rapid clinical improvement with symptom relief and normalization of respiratory function was obtained in 14 cases. Two patients died within 48 hr from causes unrelated to stent placement. Two cases (13%) of migration were observed; they were successfully treated with another stent. Tumor overgrowth developed in other 2 patients (13%); however, no further treatment was possible because of extensive laryngeal infiltration. Conclusions. Tracheobronchial recanalization with self-expandable metal stents is a safe and effective palliative treatment for malignant strictures. Airway stenting performed exclusively under fluoroscopic view was rapid and well tolerated.« less

  3. Work productivity in rheumatoid arthritis: relationship with clinical and radiological features.

    PubMed

    Chaparro Del Moral, Rafael; Rillo, Oscar Luis; Casalla, Luciana; Morón, Carolina Bru; Citera, Gustavo; Cocco, José A Maldonado; Correa, María de Los Ángeles; Buschiazzo, Emilio; Tamborenea, Natalia; Mysler, Eduardo; Tate, Guillermo; Baños, Andrea; Herscovich, Natalia

    2012-01-01

    Objective. To assess the relationship between work productivity with disease activity, functional capacity, life quality and radiological damage in patients with rheumatoid arthritis (RA). Methods. The study included consecutive employed patients with RA (ACR'87), aged over 18. Demographic, disease-related, and work-related variables were determined. The reduction of work productivity was assessed by WPAI-RA. Results. 90 patients were evaluated, 71% women. Age average is 50 years old, DAS28 4, and RAQoL 12. Median SENS is 18 and HAQ-A 0.87. Mean absenteeism was of 14%, presenting an average of 6.30 work hours wasted weekly. The reduction in performance at work or assistance was of 38.4% and the waste of productivity was of 45%. Assistance correlated with DAS28 (r = 0.446; P < 0.001), HAQ-A (r = 0.545; P < 0.001) and RAQoL (r = 0.475; P < 0.001). Lower total productivity was noticed in higher levels of activity and functional disability. Patients with SENS > 18 showed lower work productivity than those with SENS < 18 (50 versus 34; P = 0.04). In multiple regression analysis, variables associated with reduction of total work productivity were HAQ-A and RAQoL. Conclusion. RA patients with higher disease severity showed higher work productivity compromise.

  4. British Society of Interventional Radiology Iliac Artery Angioplasty-Stent Registry III

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uberoi, Raman, E-mail: raman.uberoi@orh.nhs.uk; Milburn, Simon; Moss, Jon

    2009-09-15

    The objective of this study was to audit current practice in iliac artery intervention in the United Kingdom. In 2001 the British Society of Interventional Radiology Iliac Artery Angioplasty-Stent (BIAS) III registry provided the first national database for iliac intervention. It recommended that data collection needed to continue in order to facilitate the dissemination of comparative data to individual units. BIAS III was designed to continue this work and has a simplified data set with an online submission form. Interventionalists were invited to complete a 3-page tick sheet for all iliac angioplasties and stents. Questions covered risk factors, procedural data,more » and outcome. Data for 2233 patients were submitted from 37 institutions over a 43-month period. Consultants performed 80% of the procedures, 62% of which were for claudication. Fifty-four percent of lesions were treated with stents and 25% of patients underwent bilateral intervention, resulting in a residual stenosis of <50% in 98%. Ninety-seven percent of procedures had no limb complication and there was a 98% inpatient survival rate. In conclusion, these figures provide an essential benchmark for both audit and patient information. National databases need to be expanded across the range of interventional procedures, and their collection made simple and, preferably, online.« less

  5. Enhancing Web applications in radiology with Java: estimating MR imaging relaxation times.

    PubMed

    Dagher, A P; Fitzpatrick, M; Flanders, A E; Eng, J

    1998-01-01

    Java is a relatively new programming language that has been used to develop a World Wide Web-based tool for estimating magnetic resonance (MR) imaging relaxation times, thereby demonstrating how Java may be used for Web-based radiology applications beyond improving the user interface of teaching files. A standard processing algorithm coded with Java is downloaded along with the hypertext markup language (HTML) document. The user (client) selects the desired pulse sequence and inputs data obtained from a region of interest on the MR images. The algorithm is used to modify selected MR imaging parameters in an equation that models the phenomenon being evaluated. MR imaging relaxation times are estimated, and confidence intervals and a P value expressing the accuracy of the final results are calculated. Design features such as simplicity, object-oriented programming, and security restrictions allow Java to expand the capabilities of HTML by offering a more versatile user interface that includes dynamic annotations and graphics. Java also allows the client to perform more sophisticated information processing and computation than is usually associated with Web applications. Java is likely to become a standard programming option, and the development of stand-alone Java applications may become more common as Java is integrated into future versions of computer operating systems.

  6. Work Productivity in Rheumatoid Arthritis: Relationship with Clinical and Radiological Features

    PubMed Central

    Chaparro del Moral, Rafael; Rillo, Oscar Luis; Casalla, Luciana; Morón, Carolina Bru; Citera, Gustavo; Cocco, José A. Maldonado; Correa, María de los Ángeles; Buschiazzo, Emilio; Tamborenea, Natalia; Mysler, Eduardo; Tate, Guillermo; Baños, Andrea; Herscovich, Natalia

    2012-01-01

    Objective. To assess the relationship between work productivity with disease activity, functional capacity, life quality and radiological damage in patients with rheumatoid arthritis (RA). Methods. The study included consecutive employed patients with RA (ACR'87), aged over 18. Demographic, disease-related, and work-related variables were determined. The reduction of work productivity was assessed by WPAI-RA. Results. 90 patients were evaluated, 71% women. Age average is 50 years old, DAS28 4, and RAQoL 12. Median SENS is 18 and HAQ-A 0.87. Mean absenteeism was of 14%, presenting an average of 6.30 work hours wasted weekly. The reduction in performance at work or assistance was of 38.4% and the waste of productivity was of 45%. Assistance correlated with DAS28 (r = 0.446; P < 0.001), HAQ-A (r = 0.545; P < 0.001) and RAQoL (r = 0.475; P < 0.001). Lower total productivity was noticed in higher levels of activity and functional disability. Patients with SENS > 18 showed lower work productivity than those with SENS < 18 (50 versus 34; P = 0.04). In multiple regression analysis, variables associated with reduction of total work productivity were HAQ-A and RAQoL. Conclusion. RA patients with higher disease severity showed higher work productivity compromise. PMID:23320166

  7. Excerpts from Managing CQI in Radiology and Diagnostic Imaging Services: A CQI Handbook.

    PubMed

    Joseph, E D; Lesher, C; Zage, R

    1994-01-01

    Continuous quality improvement (CQI) is currently the most popular and influential quality management program used in healthcare organizations. It is an effective methodology for identifying and acting on opportunities to improve the efficiency, effectiveness and value of services provided to customers. CQI implementation can be broken down into four components: (1) achievement objectives and goal identification, (2) system process analysis, (3) action planning and implementation, and (4) performance measurement and follow-up. As the project team establishes goals, it should consider customer and staff needs, what constitutes "quality," existing guidelines and regulations, and how results will be measured. Many techniques can be used to analyze the procedure or function targeted for improvement, including charts and diagrams, formal monitoring, data collection and statistical analysis. After the project team has identified potential service improvements, they develop an action plan, which may include education, recruitment, reassignment or equipment acquisition. The team must consider the impact of proposed changes and the financial and logistical feasibility of various proposals. The dynamic challenges of radiology and diagnostic imaging cannot be addressed through single, isolated actions; efforts to improve quality should be continuous. Accordingly, the project team should measure and analyze results of the action plan, reappraise goals and look for opportunities to further improve service.

  8. Outcome of Endoscopic Transsphenoidal Surgery in Combination with Somatostatin Analogues in Patients with Growth Hormone Producing Pituitary Adenoma

    PubMed Central

    Zhou, Tao; Wang, Fuyu; Meng, Xianghui; Ba, Jianmin; Wei, Shaobo

    2014-01-01

    Objective To determine the efficacy of endoscopic surgery in combination with long-acting somatostatin analogues (SSAs) in treating patients with growth hormone (GH)-secreting pituitary tumor. Methods We performed retrospective analysis of 133 patients with GH producing pituitary adenoma who underwent pure endoscopic transsphenoidal surgery in our center from January 2007 to July 2012. Patients were followed up for a range of 3-48 months. The radiological remission, biochemical remission and complication were evaluated. Results A total of 110 (82.7%) patients achieved radiological complete resection, 11 (8.2%) subtotal resection, and 12 (9.0%) partial resection. Eighty-eight (66.2%) patients showed nadir GH level less than 1 ng/mL after oral glucose administration. No mortality or severe disability was observed during follow up. Preoperative long-acting SSA successfully improved left ventricle ejection fraction (LVEF) and blood glucose in three patients who subsequently underwent success operation. Long-acting SSA (20 mg every 30 days) achieved biochemical remission in 19 out 23 (82.6%) patients who showed persistent high GH level after surgery. Conclusion Endoscopic transsphenoidal surgery can biochemically cure the majority of GH producing pituitary adenoma. Post-operative use of SSA can improve biochemical remission. PMID:25535518

  9. Radiological interpretation of images displayed on tablet computers: a systematic review

    PubMed Central

    Armfield, N R; Smith, A C

    2015-01-01

    Objective: To review the published evidence and to determine if radiological diagnostic accuracy is compromised when images are displayed on a tablet computer and thereby inform practice on using tablet computers for radiological interpretation by on-call radiologists. Methods: We searched the PubMed and EMBASE databases for studies on the diagnostic accuracy or diagnostic reliability of images interpreted on tablet computers. Studies were screened for inclusion based on pre-determined inclusion and exclusion criteria. Studies were assessed for quality and risk of bias using Quality Appraisal of Diagnostic Reliability Studies or the revised Quality Assessment of Diagnostic Accuracy Studies tool. Treatment of studies was reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Results: 11 studies met the inclusion criteria. 10 of these studies tested the Apple iPad® (Apple, Cupertino, CA). The included studies reported high sensitivity (84–98%), specificity (74–100%) and accuracy rates (98–100%) for radiological diagnosis. There was no statistically significant difference in accuracy between a tablet computer and a digital imaging and communication in medicine-calibrated control display. There was a near complete consensus from authors on the non-inferiority of diagnostic accuracy of images displayed on a tablet computer. All of the included studies were judged to be at risk of bias. Conclusion: Our findings suggest that the diagnostic accuracy of radiological interpretation is not compromised by using a tablet computer. This result is only relevant to the Apple iPad and to the modalities of CT, MRI and plain radiography. Advances in knowledge: The iPad may be appropriate for an on-call radiologist to use for radiological interpretation. PMID:25882691

  10. ASTRO's 2007 core physics curriculum for radiation oncology residents.

    PubMed

    Klein, Eric E; Gerbi, Bruce J; Price, Robert A; Balter, James M; Paliwal, Bhudatt; Hughes, Lesley; Huang, Eugene

    2007-08-01

    In 2004, the American Society for Therapeutic Radiology and Oncology (ASTRO) published a curriculum for physics education. The document described a 54-hour course. In 2006, the committee reconvened to update the curriculum. The committee is composed of physicists and physicians from various residency program teaching institutions. Simultaneously, members have associations with the American Association of Physicists in Medicine, ASTRO, Association of Residents in Radiation Oncology, American Board of Radiology, and American College of Radiology. Representatives from the latter two organizations are key to provide feedback between the examining organizations and ASTRO. Subjects are based on Accreditation Council for Graduate Medical Education requirements (particles and hyperthermia), whereas the majority of subjects and appropriated hours/subject were developed by consensus. The new curriculum is 55 hours, containing new subjects, redistribution of subjects with updates, and reorganization of core topics. For each subject, learning objectives are provided, and for each lecture hour, a detailed outline of material to be covered is provided. Some changes include a decrease in basic radiologic physics, addition of informatics as a subject, increase in intensity-modulated radiotherapy, and migration of some brachytherapy hours to radiopharmaceuticals. The new curriculum was approved by the ASTRO board in late 2006. It is hoped that physicists will adopt the curriculum for structuring their didactic teaching program, and simultaneously, the American Board of Radiology, for its written examination. The American College of Radiology uses the ASTRO curriculum for their training examination topics. In addition to the curriculum, the committee added suggested references, a glossary, and a condensed version of lectures for a Postgraduate Year 2 resident physics orientation. To ensure continued commitment to a current and relevant curriculum, subject matter will be updated again in 2 years.

  11. [Assessment of the correlation between histological degeneration and radiological and clinical parameters in a series of patients who underwent lumbar disc herniation surgery].

    PubMed

    Munarriz, Pablo M; Paredes, Igor; Alén, José F; Castaño-Leon, Ana M; Cepeda, Santiago; Hernandez-Lain, Aurelio; Lagares, Alfonso

    The use of histological degeneration scores in surgically-treated herniated lumbar discs is not common in clinical practice and its use has been primarily restricted to research. The objective of this study is to evaluate if there is an association between a higher grade of histological degeneration when compared with clinical or radiological parameters. Retrospective consecutive analysis of 122 patients who underwent single-segment lumbar disc herniation surgery. Clinical information was available on all patients, while the histological study and preoperative magnetic resonance imaging were also retrieved for 75 patients. Clinical variables included age, duration of symptoms, neurological deficits, or affected deep tendon reflex. The preoperative magnetic resonance imaging was evaluated using Modic and Pfirrmann scores for the affected segment by 2 independent observers. Histological degeneration was evaluated using Weiler's score; the presence of inflammatory infiltrates and neovascularization, not included in the score, were also studied. Correlation and chi-square tests were used to assess the association between histological variables and clinical or radiological variables. Interobserver agreement was also evaluated for the MRI variables using weighted kappa. No statistically significant correlation was found between histological variables (histological degeneration score, inflammatory infiltrates or neovascularization) and clinical or radiological variables. Interobserver agreement for radiological scores resulted in a kappa of 0.79 for the Pfirrmann scale and 0.65 for the Modic scale, both statistically significant. In our series of patients, we could not demonstrate any correlation between the degree of histological degeneration or the presence of inflammatory infiltrates when compared with radiological degeneration scales or clinical variables such as the patient's age or duration of symptoms. Copyright © 2017 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. ASTRO's 2007 Core Physics Curriculum for Radiation Oncology Residents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, Eric E.; Gerbi, Bruce J.; Price, Robert A.

    2007-08-01

    In 2004, American Society for Therapeutic Radiology and Oncology (ASTRO) published a curriculum for physics education. The document described a 54-hour course. In 2006, the committee reconvened to update the curriculum. The committee is composed of physicists and physicians from various residency program teaching institutions. Simultaneously, members have associations with American Association of Physicists in Medicine, ASTRO, Association of Residents in Radiation Oncology, American Board of Radiology, and American College of Radiology. Representatives from the latter two organizations are key to provide feedback between the examining organizations and ASTRO. Subjects are based on Accreditation Council for Graduate Medical Education requirementsmore » (particles and hyperthermia), whereas the majority of subjects and appropriated hours/subject were developed by consensus. The new curriculum is 55 hours, containing new subjects, redistribution of subjects with updates, and reorganization of core topics. For each subject, learning objectives are provided, and for each lecture hour, a detailed outline of material to be covered is provided. Some changes include a decrease in basic radiologic physics, addition of informatics as a subject, increase in intensity-modulated radiotherapy, and migration of some brachytherapy hours to radiopharmaceuticals. The new curriculum was approved by the ASTRO board in late 2006. It is hoped that physicists will adopt the curriculum for structuring their didactic teaching program, and simultaneously, American Board of Radiology, for its written examination. American College of Radiology uses the ASTRO curriculum for their training examination topics. In addition to the curriculum, the committee added suggested references, a glossary, and a condensed version of lectures for a Postgraduate Year 2 resident physics orientation. To ensure continued commitment to a current and relevant curriculum, subject matter will be updated again in 2 years.« less

  13. Development and validation of a questionnaire to evaluate infection control in oral radiology

    PubMed Central

    Pinelli, Camila; da Silva Tagliaferro, Elaine P; Corrente, José E; Ambrosano, Glaucia M B

    2017-01-01

    Objectives: To create and validate a questionnaire to evaluate infection control in oral radiology. Methods: The questionnaire was developed after review of the literature, which included published articles and the biosafety protocols available from healthcare agencies. The initial version of the questionnaire was composed of 14 multiple choice questions and was divided into 3 domains on handwashing, disinfection/protection of surfaces and disinfectant used. Content validity was assessed by two expert committees, which reviewed the content and scope of the questionnaire and the relevance of each item, respectively. Reliability was evaluated using test–retest and internal consistency methods with 115 undergraduate dentistry students. Construct validity was assessed using the known-groups technique and factor analysis. The known-groups technique involved 641 undergraduate dentistry students, 20 PhD students and 15 oral radiology professors. In the factor analysis, 3 radiology technicians also participated in addition to the 641 undergraduates, 20 PhD students and 15 oral radiology professors. Results: The content validity results were found to be satisfactory to excellent for the ordinal variables (intraclass correlation coefficient = 0.722–1.000) and good to great for the yes/no questions (kappa = 0.662–0.913) in terms of reliability and good internal consistency (Cronbach's alpha = 0.88). After a factor analysis, some questions were excluded, and the questions were grouped into new domains. Significant differences were observed between answers from different groups. The final version of the questionnaire was composed of nine domains. Conclusions: The questionnaire created was found to exhibit good psychometric properties for assessing infection control in oral radiology. PMID:28112553

  14. Making the invisible visible: a qualitative study of the values, attitudes and norms of radiologists relating to radiation safety.

    PubMed

    Fridell, Kent; Ekberg, Jessica

    2016-06-01

    Some shortcomings regarding safety have emerged in inspections by the Swedish Radiation Safety Authority of Swedish radiology departments which perform 5.4 million radiological examinations and 100 000 nuclear scans annually. To ensure safety in the healthcare system and to build a strong environment of radiation protection for patients (and for employees) there must be a strong culture of safety. To understand an organization's behaviour, decisions and actions it is important to study its cultural values. The aims of this study were to discuss how values, attitudes and norms affect radiologists' decisions as well as how they influence the implementation of various radiation protection measures. To investigate this, focus group interviews and in-depth individual interviews were performed in a sample from a number of radiology departments at hospitals in Sweden. The results show that the core value was derived from the patients' perspective with the focus on the knowledge that he or she has come to the healthcare system for a particular reason: to discover disease or, in the best case, to be declared healthy. The majority attitudes were based on experiences associated with aspects that the radiologist could not influence. This often concerns increased pressure on radiology investigations from clinics in the various operational units. Under the concept of norms, the radiologists in the study requested that the development of regulations and guidelines should be connected to issues of justification for various radiological queries.

  15. Management and follow-up of gallbladder polyps : Joint guidelines between the European Society of Gastrointestinal and Abdominal Radiology (ESGAR), European Association for Endoscopic Surgery and other Interventional Techniques (EAES), International Society of Digestive Surgery - European Federation (EFISDS) and European Society of Gastrointestinal Endoscopy (ESGE).

    PubMed

    Wiles, Rebecca; Thoeni, Ruedi F; Barbu, Sorin Traian; Vashist, Yogesh K; Rafaelsen, Søren Rafael; Dewhurst, Catherine; Arvanitakis, Marianna; Lahaye, Max; Soltes, Marek; Perinel, Julie; Roberts, Stuart Ashley

    2017-09-01

    The management of incidentally detected gallbladder polyps on radiological examinations is contentious. The incidental radiological finding of a gallbladder polyp can therefore be problematic for the radiologist and the clinician who referred the patient for the radiological examination. To address this a joint guideline was created by the European Society of Gastrointestinal and Abdominal Radiology (ESGAR), European Association for Endoscopic Surgery and other Interventional Techniques (EAES), International Society of Digestive Surgery - European Federation (EFISDS) and European Society of Gastrointestinal Endoscopy (ESGE). A targeted literature search was performed and consensus guidelines were created using a series of Delphi questionnaires and a seven-point Likert scale. A total of three Delphi rounds were performed. Consensus regarding which patients should have cholecystectomy, which patients should have ultrasound follow-up and the nature and duration of that follow-up was established. The full recommendations as well as a summary algorithm are provided. These expert consensus recommendations can be used as guidance when a gallbladder polyp is encountered in clinical practice. • Management of gallbladder polyps is contentious • Cholecystectomy is recommended for gallbladder polyps >10 mm • Management of polyps <10 mm depends on patient and polyp characteristics • Further research is required to determine optimal management of gallbladder polyps.

  16. Evaluation of patients diagnosed with fascioliasis: A six-year experience at a university hospital in Turkey.

    PubMed

    Boşnak, Vuslat Keçik; Karaoğlan, İlkay; Sahin, Handan Haydaroğlu; Namiduru, Mustafa; Pehlivan, Mustafa; Okan, Vahap; Mete, Ayşe Özlem

    2016-04-28

    In this study, clinical, laboratory, radiological, and serological examinations of fascioliasis patients were analyzed, and data with a significant impact on differential diagnosis were evaluated. Clinical, radiological, and laboratory findings and treatment responses of a total of 22 fascioliasis patients, treated between October 2009 and September 2014, were evaluated. Nineteen patients were diagnosed with fascioliasis at the invasive phase and three patients at the chronic phase. Patients were followed up for clinical, laboratory, and radiology findings for a period of three months to one year after treatment. The most frequent complaints in both groups were abdominal pain, and the most common physical examination finding was epigastric tenderness. In the performed examination, an eosinophil elevation in whole blood count was detected in 19 patients (100%) in the hepatic phase, and in 2 patients (66.6%) in the biliary phase. The results of the Fasciola hepatica indirect hemagglutination assay (IHA) test ordered in the diagnosis were positive in all patients. Treatment with 10 mg/kg/day triclabendazole for two consecutive days was effective. Live parasites were extracted from patients in the biliary phase with endoscopic retrograde cholangiopancreatography. In the follow-ups, remission in IHA titer and clinical and radiological improvement was achieved in all patients. If hypereosinophilia is detected by peripheral smear in patients who are admitted with complaints such as abdominal pain, weakness, nausea, myalgia, and weight loss, radiological evaluation and serological tests should be performed and fascioliasis should be considered in the differential diagnosis.

  17. Lack of security of networked medical equipment in radiology.

    PubMed

    Moses, Vinu; Korah, Ipeson

    2015-02-01

    OBJECTIVE. There are few articles in the literature describing the security and safety aspects of networked medical equipment in radiology departments. Most radiologists are unaware of the security issues. We review the security of the networked medical equipment of a typical radiology department. MATERIALS AND METHODS. All networked medical equipment in a radiology department was scanned for vulnerabilities with a port scanner and a network vulnerability scanner, and the vulnerabilities were classified using the Common Vulnerability Scoring System. A network sniffer was used to capture and analyze traffic on the radiology network for exposure of confidential patient data. We reviewed the use of antivirus software and firewalls on the networked medical equipment. USB ports and CD and DVD drives in the networked medical equipment were tested to see whether they allowed unauthorized access. Implementation of the virtual private network (VPN) that vendors use to access the radiology network was reviewed. RESULTS. Most of the networked medical equipment in our radiology department used vulnerable software with open ports and services. Of the 144 items scanned, 64 (44%) had at least one critical vulnerability, and 119 (83%) had at least one high-risk vulnerability. Most equipment did not encrypt traffic and allowed capture of confidential patient data. Of the 144 items scanned, two (1%) used antivirus software and three (2%) had a firewall enabled. The USB ports were not secure on 49 of the 58 (84%) items with USB ports, and the CD or DVD drive was not secure on 17 of the 31 (55%) items with a CD or DVD drive. One of three vendors had an insecure implementation of VPN access. CONCLUSION. Radiologists and the medical industry need to urgently review and rectify the security issues in existing networked medical equipment. We hope that the results of our study and this article also raise awareness among radiologists about the security issues of networked medical equipment.

  18. Remote inspection with multi-copters, radiological sensors and SLAM techniques

    NASA Astrophysics Data System (ADS)

    Carvalho, Henrique; Vale, Alberto; Marques, Rúben; Ventura, Rodrigo; Brouwer, Yoeri; Gonçalves, Bruno

    2018-01-01

    Activated material can be found in different scenarios, such as in nuclear reactor facilities or medical facilities (e.g. in positron emission tomography commonly known as PET scanning). In addition, there are unexpected scenarios resulting from possible accidents, or where dangerous material is hidden for terrorism attacks using nuclear weapons. Thus, a technological solution is important to cope with fast and reliable remote inspection. The multi-copter is a common type of Unmanned Aerial Vehicle (UAV) that provides the ability to perform a first radiological inspection in the described scenarios. The paper proposes a solution with a multi-copter equipped with on-board sensors to perform a 3D reconstruction and a radiological mapping of the scenario. A depth camera and a Geiger-Müler counter are the used sensors. The inspection is performed in two steps: i) a 3D reconstruction of the environment and ii) radiation activity inference to localise and quantify sources of radiation. Experimental results were achieved with real 3D data and simulated radiation activity. Experimental tests with real sources of radiation are planned in the next iteration of the work.

  19. Radiology Residents' Awareness about Ionizing Radiation Doses in Imaging Studies and Their Cancer Risk during Radiological Examinations

    PubMed Central

    Divrik Gökçe, Senem; Coşkun, Melek

    2012-01-01

    Objective Imaging methods that use ionizing radiation have been more frequent in various medical fields with advances in imaging technology. The aim of our study was to make residents be aware of the radiation dose they are subjected to when they conduct radiological imaging methods, and of cancer risk. Materials and Methods A total of 364 residents participated in this descriptive study which was conducted during the period between October, 2008 and January, 2009. The questionnaires were completed under strict control on a one-to-one basis from each department. A χ2-test was used for the evaluation of data obtained. Results Only 7% of residents correctly answered to the question about the ionizing radiation dose of a posteroanterior (PA) chest X-ray. The question asking about the equivalent number of PA chest X-rays to the ionizing dose of a brain CT was answered correctly by 24% of residents; the same question regarding abdominal CT was answered correctly by 16% of residents, thorax CT by 16%, thyroid scintigraphy by 15%, intravenous pyelography by 9%, and lumbar spine radiography by 2%. The risk of developing a cancer throughout lifetime by a brain and abdominal CT were 33% and 28%, respectively. Conclusion Radiologic residents should have updated knowledge about radiation dose content and attendant cancer risks of various radiological imaging methods during both basic medical training period and following practice period. PMID:22438688

  20. Low reproducibility between oral radiologists and general dentists with regards to radiographic diagnosis of caries.

    PubMed

    Pakbaznejad Esmaeili, Elmira; Pakkala, Tuomas; Haukka, Jari; Siukosaari, Päivi

    2018-04-12

    Early clinical and radiological diagnosis of dental caries is one of the fundamental objectives of clinical dentistry because of the high frequency of the disease and severe complications if caries remains untreated, especially among the elderly and patients with immunodeficiency. Dental panoramic tomography (DPT) is a common radiographic method for evaluating dentition when indicated, especially in an adult population. The aim of this study was to assess the reproducibility of diagnosis between specialists in oral radiology and general dentists with regards to caries lesions based on DPTs of adults. One-hundred DPTs taken from adult patients (average age 35) and then analyzed and reported on by 42 general dentists were then analyzed independently by two specialists in oral radiology with respect to caries lesions in the premolar and molar areas using radiographic criteria established for caries diagnosis. The general dentists versus oral radiologists were not calibrated before. Level of agreement between specialists and general dentists was measured using Cohen's kappa. Comparison between observations of general dentists and specialists in oral radiology showed that 61% of the caries lesions on proximal surfaces of premolars and molars observed by specialists went unobserved by general dentists. Cohen's kappa value for specialists was 0.85 (p < .001) and for each specialist and general dentists 0.48 (p < .001) and 0.44 (p < .001). The reproducibility between specialists in oral radiology and general dentists for detecting caries in DPTs was low.

  1. Architecture of next-generation information management systems for digital radiology enterprises

    NASA Astrophysics Data System (ADS)

    Wong, Stephen T. C.; Wang, Huili; Shen, Weimin; Schmidt, Joachim; Chen, George; Dolan, Tom

    2000-05-01

    Few information systems today offer a clear and flexible means to define and manage the automated part of radiology processes. None of them provide a coherent and scalable architecture that can easily cope with heterogeneity and inevitable local adaptation of applications. Most importantly, they often lack a model that can integrate clinical and administrative information to aid better decisions in managing resources, optimizing operations, and improving productivity. Digital radiology enterprises require cost-effective solutions to deliver information to the right person in the right place and at the right time. We propose a new architecture of image information management systems for digital radiology enterprises. Such a system is based on the emerging technologies in workflow management, distributed object computing, and Java and Web techniques, as well as Philips' domain knowledge in radiology operations. Our design adapts the approach of '4+1' architectural view. In this new architecture, PACS and RIS will become one while the user interaction can be automated by customized workflow process. Clinical service applications are implemented as active components. They can be reasonably substituted by applications of local adaptations and can be multiplied for fault tolerance and load balancing. Furthermore, it will provide powerful query and statistical functions for managing resources and improving productivity in real time. This work will lead to a new direction of image information management in the next millennium. We will illustrate the innovative design with implemented examples of a working prototype.

  2. Effects of instructional strategies using cross sections on the recognition of anatomical structures in correlated CT and MR images.

    PubMed

    Khalil, Mohammed K; Paas, Fred; Johnson, Tristan E; Su, Yung K; Payer, Andrew F

    2008-01-01

    This research is an effort to best utilize the interactive anatomical images for instructional purposes based on cognitive load theory. Three studies explored the differential effects of three computer-based instructional strategies that use anatomical cross-sections to enhance the interpretation of radiological images. These strategies include: (1) cross-sectional images of the head that can be superimposed on radiological images, (2) transparent highlighting of anatomical structures in radiological images, and (3) cross-sectional images of the head with radiological images presented side-by-side. Data collected included: (1) time spent on instruction and on solving test questions, (2) mental effort during instruction and test, and (3) students' performance to identify anatomical structures in radiological images. Participants were 28 freshmen medical students (15 males and 13 females) and 208 biology students (190 females and 18 males). All studies used posttest-only control group design, and the collected data were analyzed by either t test or ANOVA. In self-directed computer-based environments, the strategies that used cross sections to improve students' ability to recognize anatomic structures in radiological images showed no significant positive effects. However, when increasing the complexity of the instructional materials, cross-sectional images imposed a higher cognitive load, as indicated by higher investment of mental effort. There is not enough evidence to claim that the simultaneous combination of cross sections and radiological images has no effect on the identification of anatomical structures in radiological images for novices. Further research that control for students' learning and cognitive style is needed to reach an informative conclusion.

  3. Surgical treatment of avulsion fractures at the tibial insertion of the posterior cruciate ligament: functional result☆

    PubMed Central

    Barros, Marcos Alexandre; Cervone, Gabriel Lopes de Faria; Costa, André Luis Serigatti

    2015-01-01

    Objective To objectively and subjectively evaluate the functional result from before to after surgery among patients with a diagnosis of an isolated avulsion fracture of the posterior cruciate ligament who were treated surgically. Method Five patients were evaluated by means of reviewing the medical files, applying the Lysholm questionnaire, physical examination and radiological examination. For the statistical analysis, a significance level of 0.10 and 95% confidence interval were used. Results According to the Lysholm criteria, all the patients were classified as poor (<64 points) before the operation and evolved to a mean of 96 points six months after the operation. We observed that 100% of the posterior drawer cases became negative, taking values less than 5 mm to be negative. Conclusion Surgical methods with stable fixation for treating avulsion fractures at the tibial insertion of the posterior cruciate ligament produce acceptable functional results from the surgical and radiological points of view, with a significance level of 0.042. PMID:27218073

  4. Fixation of Radiological Contamination; International Collaborative Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rick Demmer

    2013-03-01

    A cooperative international project was conducted by the Idaho National Laboratory (INL) and the United Kingdom’s National Nuclear Laboratory (NNL) to integrate a capture coating with a high performance atomizing process. The initial results were promising, and lead to further trials. The somewhat longer testing and optimization process has resulted in a product that could be demonstrated in the field to reduce airborne radiological dust and contamination.

  5. Should radiology residents be taught evidence-based radiology? An experiment with "the EBR Journal Club".

    PubMed

    Heilbrun, Marta E

    2009-12-01

    Introduce radiology residents to evidence-based radiology (EBR) using a journal club format based on the Radiology Alliance for Health Services Research/American Alliance of Academic Chief Residents in Radiology (RAHSR/A3CR2) Critical Thinking Skills sessions and EBR series of articles published in Radiology in 2007. The club began with a presentation outlining the process that would occur in an alternating format, with topics and articles chosen by residents. In session A, questions were rephrased in a Patient/Population, Intervention, Comparison, Outcome format, and a literature search was performed. Articles were discussed in session B, with residents assigned by year to the tasks of article summary, technology assessment, and comparison to checklists (Standards for Reporting of Diagnostic Accuracy, Consolidated Standards of Reporting Trials, or Quality of Reporting of Meta-analysis). The residents collectively assigned a level of evidence to each article, and a scribe provided a summary. Twenty-two residents participated, with 12/22 (55%) of residents submitting any question, 6/22 (27.3%) submitting more than one question, and 4 residents submitting questions in more than one session. Topics included radiation risk, emergency radiology, screening examinations, modality comparisons, and technology assessment. Of the 31 articles submitted for review, 15 were in radiology journals and 5 were published before 2000. For 2/9 topics searched, no single article that the residents selected was available through our library's subscription service. The maximum level of evidence assigned by residents was level III, "limited evidence." In each session, the residents concluded that they became less confident in the "right answer." They proposed that future reading recommendations come from attendings rather than literature searches. A journal club format is an effective tool to teach radiology residents EBR principles. Resistance comes from the difficulty in accessing good literature for review and in constructing good review questions.

  6. Characteristics and trends of radiology research: a survey of original articles published in AJR and Radiology between 2001 and 2010.

    PubMed

    Lim, Kyoung Ja; Yoon, Dae Young; Yun, Eun Joo; Seo, Young Lan; Baek, Sora; Gu, Dong Hyeon; Yoon, Soo Jeong; Han, Ari; Ku, You Jin; Kim, Sam Soo

    2012-09-01

    To determine the characteristics and trends of the original articles published in two major American radiology journals, AJR American Journal of Roentgenology (AJR) and Radiology, between 2001 and 2010. This was a retrospective bibliometric analysis that did not involve human subjects and was exempt from institutional review board approval. All 6542 original articles published in AJR and Radiology between 2001 and 2010 were evaluated. The following information was abstracted from each article: radiologic subspecialty, radiologic technique used, type of research, sample size, study design, statistical analysis, study outcome, declared funding, number of authors, affiliation of the first author, and country of the first author. In addition, all the variables examined were presented along with the trend over time. The most common subspecialty of study was abdominal (1219 of 6542, 18.6%), followed by vascular/interventional (804 of 6542, 12.3%). A total of 3744 (57.2%) original articles used magnetic resonance (MR) imaging or computed tomography (CT), 5495 (84.1%) were clinical research articles, 3060 (46.8%) had sample size of more than 50, 4087 (62.5%) were retrospective, 4714 (72.1%) performed statistical analysis, 6225 (95.2%) showed positive study outcome, 4784 (73.1%) were not funded, 3942 (60.3%) had four to seven authors, and 5731 (87.6%) were written by the primary author who was from a department of radiology or radiology-related specialties. The United States published 45.5% (2975 of 6542) of the articles, followed by Japan (n = 525, 8.0%), Germany (n = 485, 7.4%), and South Korea (n = 455, 7.0%). In the time trend analysis, the following variables showed a significantly positive trend: cardiac subspecialty, CT and MR imaging as the radiologic techniques, type of research as other (nonbasic, nonclinical), sample size of more than 50, four to seven as the number of authors, medicine-related department of the first author, and South Korea and Italy as countries of the first author. On the other hand, pediatric subspecialty, combined (basic and clinical) type of research, and number of authors fewer than four showed a significantly negative trend. The bibliometric analysis of the AJR and Radiology journals with articles published between 2001 and 2010 revealed characteristics and trends of the current radiology research that may provide useful information to researchers and editorial staff in radiology. © RSNA, 2012

  7. Open reduction and internal fixation of dislocated condylar fractures in children: long-term clinical and radiologic outcomes.

    PubMed

    Deleyiannis, Frederic W-B; Vecchione, Lisa; Martin, Brian; Jiang, Shao; Sotereanos, George

    2006-11-01

    The purpose of this study was to investigate the long-term clinical and radiologic outcomes of treating dislocated condylar fractures sustained in childhood with open reduction and internal fixation (ORIF). Six children 14 years or younger with a condylar neck or subcondylar fracture with dislocation of the condyle from the glenoid fossa were treated with ORIF. Patients were followed for 27 to 92 months post-ORIF (mean: 67.6 months) with routine clinical and radiologic examinations. On the dislocated side, all patients radiographically showed signs of remodeling of the condylar process and shortening of the ramus. Subsequent to their fractures, 3 patients were classified with Angle class II malocclusion, retrognathism, and deviation of the mandibular symphysis. Four patients had objective and/or subjective signs of temporomandibular (TMJ) dysfunction. Until open surgery demonstrates a consistent functional advantage, nonsurgical management should be considered the first treatment option for the dislocated pediatric condylar fracture.

  8. Coping in a calamity: Radiology during the cloudburst at Leh

    PubMed Central

    Sen, Debraj

    2013-01-01

    The service hospital at Leh is a multispeciality hospital situated at an altitude of 11000 feet above mean sea level. On the nights of 4 and 5 Aug 2010, Leh was struck by a cloudburst leading to mudslides and consequently extensive damage to life and property. Being the only functional hospital, over a period of about 48 hours, 331 casualties were received. 549 casualties were received over the week with 108 admissions, 16 major surgeries and 138 minor surgeries. 178 radiographs, 17 CT scans and 09 ultrasound-colour Doppler examinations were performed on an urgent basis over 48 hours apart from the routine radiological investigations. Apart from chronicling the event, we hope that sharing the unique experience of the Radiology Department in dealing with the large influx of patients would provide an insight into the role of Radiology during the disaster and help in planning and developing management protocols during other calamities. PMID:23986626

  9. Radiological Characterization Methodology of INEEL Stored RH-TRU Waste from ANL-E

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rajiv N. Bhatt

    2003-02-01

    An Acceptable Knowledge (AK)-based radiological characterization methodology is being developed for RH TRU waste generated from ANL-E hot cell operations performed on fuel elements irradiated in the EBR-II reactor. The methodology relies on AK for composition of the fresh fuel elements, their irradiation history, and the waste generation and collection processes. Radiological characterization of the waste involves the estimates of the quantities of significant fission products and transuranic isotopes in the waste. Methods based on reactor and physics principles are used to achieve these estimates. Because of the availability of AK and the robustness of the calculation methods, the AK-basedmore » characterization methodology offers a superior alternative to traditional waste assay techniques. Using this methodology, it is shown that the radiological parameters of a test batch of ANL-E waste is well within the proposed WIPP Waste Acceptance Criteria limits.« less

  10. Radiological Characterization Methodology for INEEL-Stored Remote-Handled Transuranic (RH TRU) Waste from Argonne National Laboratory-East

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuan, P.; Bhatt, R.N.

    2003-01-14

    An Acceptable Knowledge (AK)-based radiological characterization methodology is being developed for RH TRU waste generated from ANL-E hot cell operations performed on fuel elements irradiated in the EBR-II reactor. The methodology relies on AK for composition of the fresh fuel elements, their irradiation history, and the waste generation and collection processes. Radiological characterization of the waste involves the estimates of the quantities of significant fission products and transuranic isotopes in the waste. Methods based on reactor and physics principles are used to achieve these estimates. Because of the availability of AK and the robustness of the calculation methods, the AK-basedmore » characterization methodology offers a superior alternative to traditional waste assay techniques. Using the methodology, it is shown that the radiological parameters of a test batch of ANL-E waste is well within the proposed WIPP Waste Acceptance Criteria limits.« less

  11. Radiological Control Center (RADCC) Renaming Ceremony

    NASA Image and Video Library

    2017-03-31

    A Mars Science Laboratory cap is displayed in the Randall E. Scott Radiological Control Center at NASA's Kennedy Space Center. The facility was recently named in honor of Randy Scott, a professional health physicist of more than 40 years. He served as the Florida spaceport's Radiation Protection Officer for 14 years until his death June 17, 2016. Launched Nov. 26, 2011, the Mars Science Laboratory with the Curiosity lander was powered by a radioisotope thermalelectric generator. Located in the Neil Armstrong Operations and Checkout building, the Randall E. Scott Radiological Control Center is staffed by technical and radiological experts from NASA, the U.S. Department of Energy, the U.S. Air Force 45th Space Wing and the state of Florida. The group performs data collection and assessment functions supporting launch site and field data collection activities during launces involving plutonium-powered spacecraft such as the Mars Science Laboratory.

  12. Action research regarding the optimisation of radiological protection for nurses during vascular interventional radiology.

    PubMed

    Mori, Hiroshige

    2015-06-01

    The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses' annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units' pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses.

  13. Use of dynamic images in radiology education: Movies of CT and MRI in the anatomy classroom.

    PubMed

    Jang, Hye Won; Oh, Chang-Seok; Choe, Yeon Hyeon; Jang, Dong Su

    2018-04-19

    Radiology education is a key component in many preclinical anatomy courses. However, the reported effectiveness of radiology education within such anatomy classrooms has varied. This study was conducted to determine if a novel educational method using dynamic images of movies of computed tomography (CT) and magnetic resonance imaging (MRI) was effective in radiology education during a preclinical anatomy course, aided by clay modeling, specific hand gestures (digit anatomy), and reports from dissection findings uploaded to the anatomy course website (digital reports). Feedback surveys using a five-point Likert scale were administered to better clarify students' opinions regarding their understanding of CT and MRI of anatomical structures, as well as to determine if such preclinical radiology education was helpful in their clinical studies. After completion of the anatomy course taught with dynamic images of CT and MRI, most students demonstrated an adequate understanding of basic CT and MR images. Additionally, students in later clinical years generally believed that their study of radiologic images during the preclinical anatomy course was helpful for their clinical studies and clerkship rotations. Moreover, student scores on imaging anatomy examinations demonstrated meaningful improvements in performance after using dynamic images from movies of CT and MRI. Anat Sci Educ. © 2018 American Association of Anatomists. © 2018 American Association of Anatomists.

  14. Comparison of the outcome following the fixation of osteotomies or fractures associated with total hip replacement using cables or wires: the results at five years.

    PubMed

    Berton, C; Puskas, G J; Christofilopoulos, P; Stern, R; Hoffmeyer, P; Lübbeke, A

    2012-11-01

    There are no recent studies comparing cable with wire for the fixation of osteotomies or fractures in total hip replacement (THR). Our objective was to evaluate the five-year clinical and radiological outcomes and complication rates of the two techniques. We undertook a review including all primary and revision THRs performed in one hospital between 1996 and 2005 using cable or wire fixation. Clinical and radiological evaluation was performed five years post-operatively. Cables were used in 51 THRs and wires in 126, and of these, 36 THRs with cable (71%) and 101 with wire (80%) were evaluated at follow-up. The five-year radiographs available for 33 cable and 91 wire THRs revealed rates of breakage of fixation of 12 of 33 (36%) and 42 of 91 (46%), respectively. With cable there was a significantly higher risk of metal debris (68% vs. 9%; adjusted relative risk (RR) 6.6; 95% confidence interval (CI) 3.0 to 14.1), nonunion (36% vs. 21%; adjusted RR 2.0; 95% CI 1.0 to 3.9) and osteolysis around the material, acetabulum or femur (61% vs 19%; adjusted RR 3.9; 95% CI 2.3 to 6.5). Cable breakage increased the risk of osteolysis to 83%. There was a trend towards foreign-body reaction and increased infection with cables. Clinical results did not differ between the groups. In conclusion, we found a higher incidence of complications and a trend towards increased infection and foreign-body reaction with the use of cables.

  15. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy

    PubMed Central

    2013-01-01

    Background Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. Methodology It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. Results A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). Conclusion CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis. PMID:23402220

  16. ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology.

    PubMed

    Khong, P-L; Ringertz, H; Donoghue, V; Frush, D; Rehani, M; Appelgate, K; Sanchez, R

    2013-04-01

    Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities - radiography and fluoroscopy, interventional radiology, and computed tomography - are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation, use of protective shielding, optimisation of exposure factors, use of pulsed fluoroscopy, limiting fluoroscopy time, etc. Major paediatric interventional procedures should be performed by experienced paediatric interventional operators, and a second, specific level of training in radiological protection is desirable (in some countries, this is mandatory). For computed tomography, dose reduction should be optimised by the adjustment of scan parameters (such as mA, kVp, and pitch) according to patient weight or age, region scanned, and study indication (e.g. images with greater noise should be accepted if they are of sufficient diagnostic quality). Other strategies include restricting multiphase examination protocols, avoiding overlapping of scan regions, and only scanning the area in question. Up-to-date dose reduction technology such as tube current modulation, organ-based dose modulation, auto kV technology, and iterative reconstruction should be utilised when appropriate. It is anticipated that this publication will assist institutions in encouraging the standardisation of procedures, and that it may help increase awareness and ultimately improve practices for the benefit of patients. Copyright © 2012. Published by Elsevier Ltd.

  17. [The balanced scorecard--applications in a radiology department].

    PubMed

    Maurer, M H; Teichgräber, U; Kröncke, T J; Hamm, B; Lemke, A J

    2012-12-01

    The balanced scorecard (BSC) represents a comprehensive management tool for organizations with the aim to focus all activities on a chosen strategy. Targets for various perspectives of the environment such as the customer, financial, process, and potential perspective are linked with concrete measures, and cause-effect relationships between the objectives are analyzed. This article shows that the BSC can also be used for the comprehensive control of a radiology department and thus provides a meaningful contribution in organizing the various diagnostic and treatment services, the management of complex clinical environment and can be of help with the tasks in research and teaching. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Evaluation of the effectiveness of Haemophilus influenzae type b conjugate vaccine introduction against radiologically-confirmed hospitalized pneumonia in young children in Ukraine.

    PubMed

    Pilishvili, Tamara; Chernyshova, Liudmyla; Bondarenko, Anastasia; Lapiy, Fedir; Sychova, Irina; Cohen, Adam; Flannery, Brendan; Hajjeh, Rana

    2013-07-01

    Haemophilus influenzae type b (Hib) conjugate vaccine was included into the national vaccination schedule of Ukraine in 2006. The objective of this study was to demonstrate the effectiveness of Hib conjugate vaccine against radiologically-confirmed hospitalized pneumonia in children. Children <2 years old with radiologically confirmed pneumonia admitted to 11 participating hospitals in Kiev and Dnepropetrovsk between April 2007 and June 2009 were included in a case-control evaluation. Four controls were matched to each case by date of birth (within 14 days) and outpatient clinic. We estimated ORs for vaccination and vaccine effectiveness ((1 - OR)*100%) using conditional logistic regression, adjusting for comorbid conditions and contraindications for vaccination. We enrolled 188 case-children and 735 controls. Median age was 16 months (range 4-24 months). Fifty-one percent of cases and 67% of controls received ≥1 doses of Hib conjugate vaccine; 26% of cases and 37% of controls received ≥3 doses. The effectiveness of ≥1 dose Hib conjugate vaccine was estimated at 45% (95% CI 18%-63%). Our study showed that Hib infections are important causes of hospitalized radiologically confirmed pneumonia in young children in Ukraine. Copyright © 2013. Published by Mosby, Inc.

  19. Multidisciplinary HIS DICOM interfaces at the Department of Veterans Affairs

    NASA Astrophysics Data System (ADS)

    Kuzmak, Peter M.; Dayhoff, Ruth E.

    2000-05-01

    The U.S. Department of Veterans Affairs (VA) is using the Digital Imaging and Communications in Medicine (DICOM) standard to integrate image data objects from multiple systems for use across the healthcare enterprise. DICOM uses a structured representation of image data and a communication mechanism that allows the VA to easily acquire images from multiple sources and store them directly into the online patient record. The VA can obtain both radiology and non- radiology images using DICOM, and can display them on low-cost clinician's color workstations throughout the medical center. High-resolution gray-scale diagnostic quality multi-monitor workstations with specialized viewing software can be used for reading radiology images. The VA's DICOM capabilities can interface six different commercial Picture Archiving and Communication Systems (PACS) and over twenty different image acquisition modalities. The VA is advancing its use of DICOM beyond radiology. New color imaging applications for Gastrointestinal Endoscopy and Ophthalmology using DICOM are under development. These are the first DICOM offerings for the vendors, who are planning to support the recently passed DICOM Visible Light and Structured Reporting service classes. Implementing these in VistA is a challenge because of the different workflow and software support for these disciplines within the VA HIS environment.

  20. Pulmonary atelectasis in newborns with clinically treatable diseases who are on mechanical ventilation: clinical and radiological aspects

    PubMed Central

    Dominguez, Mariana Chiaradia; Alvares, Beatriz Regina

    2018-01-01

    Objective To analyze the radiological aspects of pulmonary atelectasis in newborns on mechanical ventilation and treated in an intensive care unit, associating the characteristics of atelectasis with the positioning of the head and endotracheal tube seen on the chest X-ray, as well as with the clinical variables. Materials and Methods This was a retrospective cross-sectional study of 60 newborns treated between 1985 and 2015. Data were collected from medical records and radiology reports. To identify associations between variables, we used Fisher's exact test. The level of significance was set at p < 0.05. Results The clinical characteristics associated with improper positioning of the endotracheal tube were prematurity and a birth weight of less than 1000 g. Among the newborns evaluated, the most common comorbidity was hyaline membrane disease. Atelectasis was seen most frequently in the right upper lobe, although cases of total atelectasis were more common in the left lung. Malpositioning of the head showed a trend toward an association with atelectasis in the left upper lobe. Conclusion Pulmonary atelectasis is a common complication in newborns on mechanical ventilation. Radiological evaluation of the endotracheal tube placement provides relevant information for the early correction of this condition. PMID:29559762

  1. Surgical lung biopsy in transplant patients with diffuse lung disease: how much worse when the lung is the graft?

    PubMed

    Bertolotti, Alejandro; Defranchi, Sebastián; Vigliano, Carlos; Haberman, Diego; Favaloro, Roberto

    2013-07-01

    There are no data that compare the clinical presentation and results of surgical lung biopsy (SLB) for diffuse lung disease (DLD) in lung transplant patients, in contrast to individuals with other type of solid organ grafts. Our objective was to compare the clinical picture, radiologic pattern, pathology results, and outcomes of SLB for DLD in these two subsets of patients. We retrospectively reviewed the clinical records of transplant patients undergoing SLB for DLD at our institution between 2004 and 2011. Patients with lung transplants and those with other transplants were compared. During the study period, 1,232 solid organ transplants were done at our institution. Of these, 49 patients (4%) had DLD that needed SLB for diagnosis, and 24 of these patients had a lung transplant. Dyspnea and a radiologic reticular pattern were more frequent in lung transplant patients, 21 of 24 vs 11 of 25 (p = 0.001) and 14 of 24 vs 7 of 25 (p = 0.03), respectively. Although postoperative complications and in-hospital deaths were more common in lung transplant patients, the differences were not statistically significant. Having the SLB performed for diagnosis, as opposed to being conducted for DLD that did not improve on medical treatment, had a protective effect on multivariate analysis (hazard ratio, 0.39; 95% confidence interval, 0.16 to 0.96; p = 0.042). A prior lung transplant was the only independent predictor of survival (hazard ratio, 4.62; 95% confidence interval, 1.53 to 13.92, p = 0.006). It is relatively uncommon for a solid organ transplant patient with DLD to require a SLB. Clinical and radiologic presentation differ in patients with lung transplants compared with other transplants. Postoperative outcomes are not significantly different between the groups. SLB performed early in the course of the disease might be beneficial. Having a lung transplant is a significant negative predictor of survival. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Breast Tomosynthesis

    MedlinePlus

    ... and disease management. top of page How is the procedure performed? Breast tomosynthesis is performed on an outpatient basis. During this exam, a specially qualified radiologic technologist will position your breast in the mammography unit. ...

  3. Characteristics and quality of published animal research in the field of radiology.

    PubMed

    Yoon, Soo Jeong; Yoon, Dae Young; Cho, Young Kwon; Baek, Sora; Lim, Kyoung Ja; Seo, Young Lan; Yun, Eun Joo

    2017-06-01

    Background Animal research has played an important role in the field of radiology. Purpose To evaluate the characteristics and quality of published radiological animal research. Material and Methods A PubMed search was performed for radiological animal research articles (defined as studies using animal models with a radiologist as the first author) published in 1994, 2004, and 2014. The following information was extracted from each article: journal name, radiological subspecialty, imaging technique, animal species, number of animals used, number of authors, declared funding, country of origin, methodological quality, and ethical quality. Methodological and ethical quality of studies were assessed with seven-item (sample size calculation, animal age, animal sex, animal weight, inclusion and exclusion criteria, randomization, and blinded outcome assessment) and four-item (ethical review committee approval, anesthesia, pain control, and euthanasia) scales, respectively. Results The numbers of radiological animal studies markedly increased, from 91 in 1994 to 163 in 2004 and to 305 in 2014. One hundred and sixty-two (29.0%) articles focused on the neuroradiology/head and neck subspecialty, 233 (41.7%) used magnetic resonance imaging (MRI), 190 (34.0%) used mice, 254 (45.4%) used 10-30 animals, 297 (53.1%) had 4-7 authors, 392 (70.1%) were funded, and 222 (39.7%) were from the USA. Six of 7 methodological and 3/4 ethical quality items significantly improved over time. Conclusion The quantity and quality of radiological animal research has increased over the last two decades; however, methodological and ethical quality remains suboptimal.

  4. Sciatica-like symptoms and the sacroiliac joint: clinical features and differential diagnosis.

    PubMed

    Visser, L H; Nijssen, P G N; Tijssen, C C; van Middendorp, J J; Schieving, J

    2013-07-01

    To compare the clinical features of patients with sacroiliac joint (SIJ)-related sciatica-like symptoms to those with sciatica from nerve root compression and to investigate the necessity to perform radiological imaging in patients with sciatica-like symptoms derived from the SIJ. Patients with pain radiating below the buttocks with a duration of 4 weeks to 1 year were included. After physical and radiological examinations, a diagnosis of SI joint-related pain, pain due to disk herniation, or a combination of these two causes was made. Patients with SIJ-related leg pain (n = 77/186) were significantly more often female, had shorter statue, a shorter duration of symptoms, and had more often pain radiating to the groin and a history of a fall on the buttocks. Muscle weakness, corkscrew phenomenon, finger-floor distance ≥25 cm, lumbar scoliosis, positive Bragard or Kemp sign, and positive leg raising test were more often present when radiologic nerve root compression was present. Although these investigations may help, MRI of the spine is necessary to discriminate between the groups. Sciatica-like symptoms derived from the SIJ can clinically mimic a radiculopathy. We suggest to perform a thorough physical examination of the spine, SI joints, and hips with additional radiological tests to exclude other causes.

  5. Design and Implementation of PACS at Georgetown University Hospital

    NASA Astrophysics Data System (ADS)

    Mun, S. K.; Benson, H.. R.; Choyke, P.; Fahey, F. H.; Wang, P. C.; Zeman, R. K...; Elliott, L. P.

    1985-09-01

    During the preparation and planning phase of the PACS project at Georgetown University Hospital it was realized that PACS requires truly the state of the art technology in data communication, image processing and man machine interfacing. It was also realized that un-like many other technology intensive devices used in radiology, PACS cannot be seen as an independent system that will provide well defined services. PACS will be the backbone of the department operation in clinical, educational and managerial functions. It will indeed be the nerve center of the radiologic services affecting every aspect of the department. PACS will have to be designed to perform in a cost-effective manner to widely varying needs within the radiology departments. The integration of ever changing complex technology that will impact every aspect of a radiology service is not a trivial matter. This transition period going from current manual film based PACS to Digital PACS can be long, expansive and disruptive unless careful planning preceeds the implementation. PACS is still an emerging technology at its infancy. Performance monitoring and evaluation of diversified functions have to be also established so that improvement to the system can be efficiently implemented. Thus the evaluation criteria should be also established as early as possible.

  6. [The trial of business data analysis at the Department of Radiology by constructing the auto-regressive integrated moving-average (ARIMA) model].

    PubMed

    Tani, Yuji; Ogasawara, Katsuhiko

    2012-01-01

    This study aimed to contribute to the management of a healthcare organization by providing management information using time-series analysis of business data accumulated in the hospital information system, which has not been utilized thus far. In this study, we examined the performance of the prediction method using the auto-regressive integrated moving-average (ARIMA) model, using the business data obtained at the Radiology Department. We made the model using the data used for analysis, which was the number of radiological examinations in the past 9 years, and we predicted the number of radiological examinations in the last 1 year. Then, we compared the actual value with the forecast value. We were able to establish that the performance prediction method was simple and cost-effective by using free software. In addition, we were able to build the simple model by pre-processing the removal of trend components using the data. The difference between predicted values and actual values was 10%; however, it was more important to understand the chronological change rather than the individual time-series values. Furthermore, our method was highly versatile and adaptable compared to the general time-series data. Therefore, different healthcare organizations can use our method for the analysis and forecasting of their business data.

  7. Returning to work after multimodal treatment in glioblastoma patients.

    PubMed

    Starnoni, Daniele; Berthiller, Julien; Idriceanu, Tania-Mihaela; Meyronet, David; d'Hombres, Anne; Ducray, François; Guyotat, Jacques

    2018-06-01

    OBJECTIVE Although multimodal treatment for glioblastoma (GBM) has resulted in longer survival, uncertainties exist regarding health-related quality of life and functional performance. Employment represents a useful functional end point and an indicator of social reintegration. The authors evaluated the rate of patients resuming their employment and the factors related to work capacity. METHODS The authors performed a retrospective study of working-age patients treated with surgery and radiochemotherapy between 2012 and 2015. Data were collected before and after surgery and at 6, 12, 18, and 24 months. Employment was categorized according to the French Socio-Professional Groups and analyzed regarding demographic and clinical data, performance status, socio-professional category, radiological features, type, and quality of resection. RESULTS A total of 125 patients, mean age 48.2 years, were identified. The mean follow-up was 20.7 months with a median survival of 22.9 months. Overall, 21 patients (18.3%) went back to work, most on a part-time basis (61.9%). Of the patients who were alive at 6, 12, 18, and 24 months after diagnosis, 8.7%, 13.8%, 15.3%, and 28.2%, respectively, were working. Patients going back to work were younger (p = 0.03), had fewer comorbidities (p = 0.02), and had a different distribution of socio-professional groups, with more patients belonging to higher occupation categories (p = 0.02). Treatment-related symptoms (36.2%) represented one of the main factors that prevented the resumption of work. Employment was strongly associated with performance status (p = 0.002) as well as gross-total removal (p = 0.04). No statistically significant difference was found regarding radiological or molecular features and the occurrence of complications after surgery. CONCLUSIONS GBM diagnosis and treatment has a significant socio-professional impact with only a minority of patients resuming work, mostly on a part-time basis.

  8. Flow volume loops in patients with goiters.

    PubMed Central

    Geraghty, J G; Coveney, E C; Kiernan, M; O'Higgins, N J

    1992-01-01

    Plain radiology is the standard means of assessing upper airway obstruction in patients with goiters. Flow volume loop curves will provide additional information, because they allow a quantitative assessment of airflow dynamics in the respiratory cycle. Fifty-one patients had flow volume loops performed before and after thyroidectomy. There was a significant increase in the maximum inspiratory flow rate (3.9 +/- 0.2 versus 4.9 +/- 0.2 L/second, p less than 0.01) after thyroidectomy. Eight of twelve patients with normal tracheal radiology had improved airflow dynamics in the postoperative period. The flow volume loop curve is a simple noninvasive means of assessing airflow dynamics in patients with goiters and may be superior to conventional radiology. PMID:1731653

  9. Alternative Payment Models in Radiology: The Legislative and Regulatory Roadmap for Reform.

    PubMed

    Silva, Ezequiel; McGinty, Geraldine B; Hughes, Danny R; Duszak, Richard

    2016-10-01

    The Medicare Access and CHIP Reauthorization Act (MACRA) replaces the sustainable growth rate with a payment system based on the Merit-Based Incentive Payment System and incentives for alternative payment model participation. It is important that radiologists understand the statutory requirements of MACRA. This includes the nature of the Merit-Based Incentive Payment System composite performance score and its impact on payments. The timeline for MACRA implementation is fairly aggressive and includes a robust effort to define episode groups, which include radiologic services. A number of organizations, including the ACR, are commenting on the structure of MACRA-directed initiatives. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. [Management of acute and subacute clinical situations by interventional radiology: non-vascular interventions and treatment for hemoptysis].

    PubMed

    Nemes, Balázs; Doros, Attila

    2015-04-26

    Interventional radiology provides fast, straightforward and tolerable solutions for many medical problems including acute and subacute situations. Aspiration and drainage of fluid collections, biliary and endourologic interventions and gastrointestinal interventions are parts of non-vascular interventions. In addition, the authors discuss in detail interventional radiological treatment options in patients with hemoptysis. In acute cases interventions must be performed within 12-24 hours. For background, an everyday 24 hours service should be provided with well-trained personnel, high quality equipment and devices, and a reasonable financial reimbursement should be included, too. Multidisciplinary teamwork, consultations, consensus in indications and structured education should make these centers function most effectively.

  11. An empirical evaluation of supervised learning approaches in assigning diagnosis codes to electronic medical records

    PubMed Central

    Kavuluru, Ramakanth; Rios, Anthony; Lu, Yuan

    2015-01-01

    Background Diagnosis codes are assigned to medical records in healthcare facilities by trained coders by reviewing all physician authored documents associated with a patient's visit. This is a necessary and complex task involving coders adhering to coding guidelines and coding all assignable codes. With the popularity of electronic medical records (EMRs), computational approaches to code assignment have been proposed in the recent years. However, most efforts have focused on single and often short clinical narratives, while realistic scenarios warrant full EMR level analysis for code assignment. Objective We evaluate supervised learning approaches to automatically assign international classification of diseases (ninth revision) - clinical modification (ICD-9-CM) codes to EMRs by experimenting with a large realistic EMR dataset. The overall goal is to identify methods that offer superior performance in this task when considering such datasets. Methods We use a dataset of 71,463 EMRs corresponding to in-patient visits with discharge date falling in a two year period (2011–2012) from the University of Kentucky (UKY) Medical Center. We curate a smaller subset of this dataset and also use a third gold standard dataset of radiology reports. We conduct experiments using different problem transformation approaches with feature and data selection components and employing suitable label calibration and ranking methods with novel features involving code co-occurrence frequencies and latent code associations. Results Over all codes with at least 50 training examples we obtain a micro F-score of 0.48. On the set of codes that occur at least in 1% of the two year dataset, we achieve a micro F-score of 0.54. For the smaller radiology report dataset, the classifier chaining approach yields best results. For the smaller subset of the UKY dataset, feature selection, data selection, and label calibration offer best performance. Conclusions We show that datasets at different scale (size of the EMRs, number of distinct codes) and with different characteristics warrant different learning approaches. For shorter narratives pertaining to a particular medical subdomain (e.g., radiology, pathology), classifier chaining is ideal given the codes are highly related with each other. For realistic in-patient full EMRs, feature and data selection methods offer high performance for smaller datasets. However, for large EMR datasets, we observe that the binary relevance approach with learning-to-rank based code reranking offers the best performance. Regardless of the training dataset size, for general EMRs, label calibration to select the optimal number of labels is an indispensable final step. PMID:26054428

  12. Digital versus analogue preoperative planning of total hip arthroplasties: a randomized clinical trial of 210 total hip arthroplasties.

    PubMed

    The, Bertram; Verdonschot, Nico; van Horn, Jim R; van Ooijen, Peter M A; Diercks, Ron L

    2007-09-01

    The objective of this randomized clinical trial was to compare the clinical and technical results of digital preoperative planning for primary total hip arthroplasties with analogue planning. Two hundred and ten total hip arthroplasties were randomized. All plans were constructed on standardized radiographs by the surgeon who performed the arthroplasty the next day. The main outcome was accuracy of the preoperative plan. Secondary outcomes were operation time and a radiographic assessment of the arthroplasty. Digital preoperative plans were more accurate in planning the cup (P < .05) and scored higher on the postoperative radiologic assessment of cemented cup (P = .03) and stem (P < .01) components. None of the other comparisons reached statistical significance. We conclude that digital plans slightly outperform analogue plans.

  13. Principle and engineering implementation of 3D visual representation and indexing of medical diagnostic records (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Shi, Liehang; Sun, Jianyong; Yang, Yuanyuan; Ling, Tonghui; Wang, Mingqing; Zhang, Jianguo

    2017-03-01

    Purpose: Due to the generation of a large number of electronic imaging diagnostic records (IDR) year after year in a digital hospital, The IDR has become the main component of medical big data which brings huge values to healthcare services, professionals and administration. But a large volume of IDR presented in a hospital also brings new challenges to healthcare professionals and services as there may be too many IDRs for each patient so that it is difficult for a doctor to review all IDR of each patient in a limited appointed time slot. In this presentation, we presented an innovation method which uses an anatomical 3D structure object visually to represent and index historical medical status of each patient, which is called Visual Patient (VP) in this presentation, based on long term archived electronic IDR in a hospital, so that a doctor can quickly learn the historical medical status of the patient, quickly point and retrieve the IDR he or she interested in a limited appointed time slot. Method: The engineering implementation of VP was to build 3D Visual Representation and Index system called VP system (VPS) including components of natural language processing (NLP) for Chinese, Visual Index Creator (VIC), and 3D Visual Rendering Engine.There were three steps in this implementation: (1) an XML-based electronic anatomic structure of human body for each patient was created and used visually to index the all of abstract information of each IDR for each patient; (2)a number of specific designed IDR parsing processors were developed and used to extract various kinds of abstract information of IDRs retrieved from hospital information systems; (3) a 3D anatomic rendering object was introduced visually to represent and display the content of VIO for each patient. Results: The VPS was implemented in a simulated clinical environment including PACS/RIS to show VP instance to doctors. We setup two evaluation scenario in a hospital radiology department to evaluate whether radiologists accept the VPS and how the VP impact the radiologists' efficiency and accuracy in reviewing historic medical records of the patients. We got a statistical results showing that more than 70% participated radiologist would like to use the VPS in their radiological imaging services. In comparison testing of using VPS and RIS/PACS in reviewing historic medical records of the patients, we got a statistical result showing that the efficiency of using VPS was higher than that of using PACS/RIS. New Technologies and Results to be presented: This presentation presented an innovation method to use an anatomical 3D structure object, called VP, visually to represent and index historical medical records such as IDR of each patient and a doctor can quickly learn the historical medical status of the patient through VPS. The evaluation results showed that VPS has better performance than RIS-integrated PACS in efficiency of reviewing historic medical records of the patients. Conclusions: In this presentation, we presented an innovation method called VP to use an anatomical 3D structure object visually to represent and index historical IDR of each patient and briefed an engineering implementation to build a VPS to implement the major features and functions of VP. We setup two evaluation scenarios in a hospital radiology department to evaluate VPS and achieved evaluation results showed that VPS has better performance than RIS-integrated PACS in efficiency of reviewing historic medical records of the patients.

  14. Degenerative lumbar spinal stenosis: correlation with Oswestry Disability Index and MR imaging.

    PubMed

    Sirvanci, Mustafa; Bhatia, Mona; Ganiyusufoglu, Kursat Ali; Duran, Cihan; Tezer, Mehmet; Ozturk, Cagatay; Aydogan, Mehmet; Hamzaoglu, Azmi

    2008-05-01

    Because neither the degree of constriction of the spinal canal considered to be symptomatic for lumbar spinal stenosis nor the relationship between the clinical appearance and the degree of a radiologically verified constriction is clear, a correlation of patient's disability level and radiographic constriction of the lumbar spinal canal is of interest. The aim of this study was to establish a relationship between the degree of radiologically established anatomical stenosis and the severity of self-assessed Oswestry Disability Index in patients undergoing surgery for degenerative lumbar spinal stenosis. Sixty-three consecutive patients with degenerative lumbar spinal stenosis who were scheduled for elective surgery were enrolled in the study. All patients underwent preoperative magnetic resonance imaging and completed a self-assessment Oswestry Disability Index questionnaire. Quantitative image evaluation for lumbar spinal stenosis included the dural sac cross-sectional area, and qualitative evaluation of the lateral recess and foraminal stenosis were also performed. Every patient subsequently answered the national translation of the Oswestry Disability Index questionnaire and the percentage disability was calculated. Statistical analysis of the data was performed to seek a relationship between radiological stenosis and percentage disability recorded by the Oswestry Disability Index. Upon radiological assessment, 27 of the 63 patients evaluated had severe and 33 patients had moderate central dural sac stenosis; 11 had grade 3 and 27 had grade 2 nerve root compromise in the lateral recess; 22 had grade 3 and 37 had grade 2 foraminal stenosis. On the basis of the percentage disability score, of the 63 patients, 10 patients demonstrated mild disability, 13 patients moderate disability, 25 patients severe disability, 12 patients were crippled and three patients were bedridden. Radiologically, eight patients with severe central stenosis and nine patients with moderate lateral stenosis demonstrated only minimal disability on percentage Oswestry Disability Index scores. Statistical evaluation of central and lateral radiological stenosis versus Oswestry Disability Index percentage scores showed no significant correlation. In conclusion, lumbar spinal stenosis remains a clinico-radiological syndrome, and both the clinical picture and the magnetic resonance imaging findings are important when evaluating and discussing surgery with patients having this diagnosis. MR imaging has to be used to determine the levels to be decompressed.

  15. Information extraction from multi-institutional radiology reports.

    PubMed

    Hassanpour, Saeed; Langlotz, Curtis P

    2016-01-01

    The radiology report is the most important source of clinical imaging information. It documents critical information about the patient's health and the radiologist's interpretation of medical findings. It also communicates information to the referring physicians and records that information for future clinical and research use. Although efforts to structure some radiology report information through predefined templates are beginning to bear fruit, a large portion of radiology report information is entered in free text. The free text format is a major obstacle for rapid extraction and subsequent use of information by clinicians, researchers, and healthcare information systems. This difficulty is due to the ambiguity and subtlety of natural language, complexity of described images, and variations among different radiologists and healthcare organizations. As a result, radiology reports are used only once by the clinician who ordered the study and rarely are used again for research and data mining. In this work, machine learning techniques and a large multi-institutional radiology report repository are used to extract the semantics of the radiology report and overcome the barriers to the re-use of radiology report information in clinical research and other healthcare applications. We describe a machine learning system to annotate radiology reports and extract report contents according to an information model. This information model covers the majority of clinically significant contents in radiology reports and is applicable to a wide variety of radiology study types. Our automated approach uses discriminative sequence classifiers for named-entity recognition to extract and organize clinically significant terms and phrases consistent with the information model. We evaluated our information extraction system on 150 radiology reports from three major healthcare organizations and compared its results to a commonly used non-machine learning information extraction method. We also evaluated the generalizability of our approach across different organizations by training and testing our system on data from different organizations. Our results show the efficacy of our machine learning approach in extracting the information model's elements (10-fold cross-validation average performance: precision: 87%, recall: 84%, F1 score: 85%) and its superiority and generalizability compared to the common non-machine learning approach (p-value<0.05). Our machine learning information extraction approach provides an effective automatic method to annotate and extract clinically significant information from a large collection of free text radiology reports. This information extraction system can help clinicians better understand the radiology reports and prioritize their review process. In addition, the extracted information can be used by researchers to link radiology reports to information from other data sources such as electronic health records and the patient's genome. Extracted information also can facilitate disease surveillance, real-time clinical decision support for the radiologist, and content-based image retrieval. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Retrospective review of the performance standard for diagnostic x-ray equipment; availability of report--FDA. Notice; final rule-related.

    PubMed

    1985-11-12

    The Food and Drug Administration (FDA) is announcing the availability of a report prepared by the X-Ray Standard Review Group (XSRG) in FDA's Center for Devices and Radiological Health (CDRH). The report contains the review group's assessment of the performance standard for diagnostic x-ray systems and their major components. It contains recommendations for changes in the standard with respect to the need to ensure that regulatory controls keep pace with developing technology and the needs of the radiological community. In addition, FDA is inviting interested persons to submit written comments, data, or information regarding the report for the agency's consideration in deciding whether to initiate any changes in the performance standard.

  17. Radiology Reporting System Data Exchange With the Electronic Health Record System: A Case Study in Iran.

    PubMed

    Ahmadi, Maryam; Ghazisaeidi, Marjan; Bashiri, Azadeh

    2015-03-18

    In order to better designing of electronic health record system in Iran, integration of health information systems based on a common language must be done to interpret and exchange this information with this system is required. This study provides a conceptual model of radiology reporting system using unified modeling language. The proposed model can solve the problem of integration this information system with the electronic health record system. By using this model and design its service based, easily connect to electronic health record in Iran and facilitate transfer radiology report data. This is a cross-sectional study that was conducted in 2013. The study population was 22 experts that working at the Imaging Center in Imam Khomeini Hospital in Tehran and the sample was accorded with the community. Research tool was a questionnaire that prepared by the researcher to determine the information requirements. Content validity and test-retest method was used to measure validity and reliability of questioner respectively. Data analyzed with average index, using SPSS. Also Visual Paradigm software was used to design a conceptual model. Based on the requirements assessment of experts and related texts, administrative, demographic and clinical data and radiological examination results and if the anesthesia procedure performed, anesthesia data suggested as minimum data set for radiology report and based it class diagram designed. Also by identifying radiology reporting system process, use case was drawn. According to the application of radiology reports in electronic health record system for diagnosing and managing of clinical problem of the patient, with providing the conceptual Model for radiology reporting system; in order to systematically design it, the problem of data sharing between these systems and electronic health records system would eliminate.

  18. Radiology and social media: are private practice radiology groups more social than academic radiology departments?

    PubMed

    Glover, McKinley; Choy, Garry; Boland, Giles W; Saini, Sanjay; Prabhakar, Anand M

    2015-05-01

    This study assesses the prevalence of use of the most commonly used social media sites among private radiology groups (PRGs) and academic radiology departments (ARDs). The 50 largest PRGs and the 50 ARDs with the highest level of funding from the National Institutes of Health were assessed for presence of a radiology-specific social media account on Facebook, Twitter, Instagram, Pinterest, YouTube, and LinkedIn. Measures of organizational activity and end-user activity were collected, including the number of posts and followers, as appropriate; between-group comparisons were performed. PRGs adopted Facebook 12 months earlier (P = .02) and Twitter 18 months earlier (P = .02) than did ARDs. A total of 76% of PRGs maintained ≥1 account on the social media sites included in the study, compared with 28% of ARDs (P < .0001). The prevalence of having an account on the social media sites for PRGs was: Facebook, 66%; LinkedIn, 56%; Twitter, 42%; YouTube, 20%; Pinterest, 4%; and Instagram, 2%. The prevalence of radiology-specific social media accounts for ARDs was: Facebook, 18%; LinkedIn, 0%; Twitter, 24%; YouTube, 6%; Pinterest, 0%; and Instagram, 0%. There was no significant difference between ARDs and PRGs in measures of end-user or organizational activity on Facebook or Twitter. Use of social media in health care is emerging as mainstream, with PRGs being early adopters of Facebook and Twitter in comparison with ARDs. Competitive environments and institutional policies may be strong factors that influence how social media is used by radiologists at the group and department levels. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  19. Familiarity with current practices of granting and maintaining privileges in pediatric interventional radiology--a worldwide survey of the members of the Society for Pediatric Interventional Radiology (SPIR).

    PubMed

    Harned, Roger K

    2012-11-01

    Physician credentialing is a complex process driven by the demand for quality improvement in health care. In the U.S., the Joint Commission Standard of 2007 has tied hospital accreditation to credentialing through mandated use of the Focused Professional Practice Evaluation (FPPE) and Ongoing Professional Practice Evaluation (OPPE). To assess pediatric interventional radiologists' knowledge of how institutions grant them privileges. Members of the Society for Pediatric Interventional Radiology (SPIR) were sent a web-based survey regarding credentialing. Of 122 members from 19 countries, 81 (66%) responded, and of these 81, 59 (73%) were familiar with their hospital's privileging process. Of 49 U.S. respondents and 32 non-U.S. respondents, 37 (76%) and 17 (53%), respectively, stated that interventional radiology credentialing was different from diagnostic radiology credentialing. Of the 49 U.S. respondents, 24 (49%) reported an OPPE, and of the 32 non-U.S. respondents, 8 (25%) reported an ongoing evaluation. The U.S. OPPE is performed at shorter intervals than its international equivalent. Four years after the Joint Commission defined the FPPE and OPPE, separate credentialing of pediatric interventional radiology from pediatric diagnostic radiology is more likely in the U.S. than internationally, and U.S. pediatric interventional radiologists are more likely to have a defined ongoing professional evaluation and to be evaluated every 6 months or more frequently. There are many SPIR members who do not know how they obtain privileges and/or are not knowingly subject to an OPPE. This lack of knowledge may affect future education of interventional radiologists as well as the definition of pediatric interventional radiology practices within individual institutions.

  20. Congenital Portosystemic Shunts: Clinic Heterogeneity Requires an Individual Management of the Patient.

    PubMed

    Chocarro, Gloria; Amesty, María Virginia; Encinas, Jose Luis; Vilanova Sánchez, Alejandra; Hernandez, Francisco; Andres, Ane M; Gamez, Manolo; Tovar, Juan Antonio; Lopez Santamaria, Manuel

    2016-02-01

    Congenital portosystemic shunt (CPSS) is a rare entity without insufficiency in treatment issues. The aim of this article is to show our experience in the heterogeneity of this condition. A retrospective study of 25 CPSS in the period 1995 to 2014 was conducted. Description of the morphology, clinical impact, and treatment is given. According to the imaging techniques (IT), the shunt was apparently intrahepatic in 14 patients, extrahepatic in 10 patients, and mixed in 1 patient. In 14 children, IT showed hepatic portal circulation. In total shunts in which radiological examination was performed, invasive radiological techniques were able to demonstrate intrahepatic portal vein. In other patients, it was not investigated as they are asymptomatic. A child presented multiorgan failure with fulminant hepatic failure at birth. The shunt was radiologically closed and clinical impairment reversed rapidly. He is now asymptomatic with no longer images of CPSS in ultrasound scan controls. Also, seven children are asymptomatic at this time and are monitored periodically. Seven children had prenatal diagnosis, in five the shunt closed spontaneously. Nine children were symptomatic in their evolution (hyperammonemia, regenerative nodules, cholestasis, gastrointestinal bleeding). Of these, in five we performed balloon test occlusion, tolerated in all patients, followed by radiological closure. In our experience, the advancement of interventional radiology techniques avoided surgery to close the shunt. Morphologically, the CPSS is extremely heterogeneous, with multiple possible connections established. CPSS has multiple clinical presentations, from asymptomatic patients to acute liver failure. The therapeutic approach should be individualized and therefore held in overspecialized centers. Georg Thieme Verlag KG Stuttgart · New York.

  1. Automatically inserted technical details improve radiology report accuracy.

    PubMed

    Abujudeh, Hani H; Govindan, Siddharth; Narin, Ozden; Johnson, Jamlik Omari; Thrall, James H; Rosenthal, Daniel I

    2011-09-01

    To assess the effect of automatically inserted technical details on the concordance of a radiology report header with the actual procedure performed. The study was IRB approved and informed consent was waived. We obtained radiology report audit data from the hospital's compliance office from the period of January 2005 through December 2009 spanning a total of 20 financial quarters. A "discordance percentage" was defined as the percentage of total studies in which a procedure code change was made during auditing. Using Chi-square analysis we compared discordance percentages between reports with manually inserted technical details (MITD) and automatically inserted technical details (AITD). The second quarter data of 2007 was not included in the analysis as the switch from MITD to AITD occurred during this quarter. The hospital's compliance office audited 9,110 studies from 2005-2009. Excluding the 564 studies in the second quarter of 2007, we analyzed a total of 8,546 studies, 3,948 with MITD and 4,598 with AITD. The discordance percentage in the MITD group was 3.95% (156/3,948, range per quarter, 1.5- 6.1%). The AITD discordance percentage was 1.37% (63/4,598, range per quarter, 0.0-2.6%). A Chi-square analysis determined a statistically significant difference between the 2 groups (P < 0.001). There was a statistically significant improvement in the concordance of a radiology report header with the performed procedure using automatically inserted technical details compared to manually inserted details. Copyright © 2011 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. "Flipping" the introductory clerkship in radiology: impact on medical student performance and perceptions.

    PubMed

    Belfi, Lily M; Bartolotta, Roger J; Giambrone, Ashley E; Davi, Caryn; Min, Robert J

    2015-06-01

    Among methods of "blended learning" (ie, combining online modules with in-class instruction), the "flipped classroom" involves student preclass review of material while reserving class time for interactive knowledge application. We integrated blended learning methodology in a "flipped" introductory clerkship in radiology, and assessed the impact of this approach on the student educational experience (performance and perception). In preparation for the "flipped clerkship," radiology faculty and residents created e-learning modules that were uploaded to an open-source website. The clerkship's 101 rising third-year medical students were exposed to different teaching methods during the course, such as blended learning, traditional lecture learning, and independent learning. Students completed precourse and postcourse knowledge assessments and surveys. Student knowledge improved overall as a result of taking the course. Blended learning achieved greater pretest to post-test improvement of high statistical significance (P value, .0060) compared to lecture learning alone. Blended learning also achieved greater pretest to post-test improvement of borderline statistical significance (P value, .0855) in comparison to independent learning alone. The difference in effectiveness of independent learning versus lecture learning was not statistically significant (P value, .2730). Student perceptions of the online modules used in blended learning portions of the course were very positive. They specifically enjoyed the self-paced interactivity and the ability to return to the modules in the future. Blended learning can be successfully applied to the introductory clerkship in radiology. This teaching method offers educators an innovative and efficient approach to medical student education in radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  3. Imaging Practice Patterns: Referral Network Analysis of a Single State of Origination.

    PubMed

    Grayson, James; Basciano, Peter; Rawson, James V; Klein, Kandace

    2015-12-01

    The aim of this study was to examine the referral pattern of imaging studies requested in a single state compared with the potential location of interpretation. Analysis of Medicare patients in a DocGraph data set was performed to identify sequential different physician services claims for the same patient for which the second claim was for services provided by a radiologist. In the 2011 Medicare population, radiology referrals from physicians practicing in Georgia resulted in 76.5% of radiology interpretations by radiologists inside the state of Georgia. The states bordering Georgia accounted for 11.6% of interpretations in the Georgia market. The remaining interpretations were distributed throughout the remainder of the country. A significant proportion of routine imaging interpretation occurs outside the state in which an examination is performed. Additional studies are needed to identify complex drivers of imaging referral patterns, such as patient geographic location and demographics, radiologist workforce distribution, contractual obligations, and social relationships. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  4. Automatic Identification of Critical Follow-Up Recommendation Sentences in Radiology Reports

    PubMed Central

    Yetisgen-Yildiz, Meliha; Gunn, Martin L.; Xia, Fei; Payne, Thomas H.

    2011-01-01

    Communication of follow-up recommendations when abnormalities are identified on imaging studies is prone to error. When recommendations are not systematically identified and promptly communicated to referrers, poor patient outcomes can result. Using information technology can improve communication and improve patient safety. In this paper, we describe a text processing approach that uses natural language processing (NLP) and supervised text classification methods to automatically identify critical recommendation sentences in radiology reports. To increase the classification performance we enhanced the simple unigram token representation approach with lexical, semantic, knowledge-base, and structural features. We tested different combinations of those features with the Maximum Entropy (MaxEnt) classification algorithm. Classifiers were trained and tested with a gold standard corpus annotated by a domain expert. We applied 5-fold cross validation and our best performing classifier achieved 95.60% precision, 79.82% recall, 87.0% F-score, and 99.59% classification accuracy in identifying the critical recommendation sentences in radiology reports. PMID:22195225

  5. Automatic identification of critical follow-up recommendation sentences in radiology reports.

    PubMed

    Yetisgen-Yildiz, Meliha; Gunn, Martin L; Xia, Fei; Payne, Thomas H

    2011-01-01

    Communication of follow-up recommendations when abnormalities are identified on imaging studies is prone to error. When recommendations are not systematically identified and promptly communicated to referrers, poor patient outcomes can result. Using information technology can improve communication and improve patient safety. In this paper, we describe a text processing approach that uses natural language processing (NLP) and supervised text classification methods to automatically identify critical recommendation sentences in radiology reports. To increase the classification performance we enhanced the simple unigram token representation approach with lexical, semantic, knowledge-base, and structural features. We tested different combinations of those features with the Maximum Entropy (MaxEnt) classification algorithm. Classifiers were trained and tested with a gold standard corpus annotated by a domain expert. We applied 5-fold cross validation and our best performing classifier achieved 95.60% precision, 79.82% recall, 87.0% F-score, and 99.59% classification accuracy in identifying the critical recommendation sentences in radiology reports.

  6. Implementation of quality assurance in diagnostic radiology in Bosnia and Herzegovina (Republic of Srpska).

    PubMed

    Bosnjak, J; Ciraj-Bjelac, O; Strbac, B

    2008-01-01

    Application of a quality control (QC) programme is very important when optimisation of image quality and reduction of patient exposure is desired. QC surveys of diagnostics imaging equipment in Republic of Srpska (entity of Bosnia and Herzegovina) has been systematically performed since 2001. The presented results are mostly related to the QC test results of X-ray tubes and generators for diagnostic radiology units in 92 radiology departments. In addition, results include workplace monitoring and usage of personal protective devices for staff and patients. Presented results showed the improvements in the implementation of the QC programme within the period 2001--2005. Also, more attention is given to appropriate maintenance of imaging equipment, which was one of the main problems in the past. Implementation of a QC programme is a continuous and complex process. To achieve good performance of imaging equipment, additional tests are to be introduced, along with image quality assessment and patient dosimetry. Training is very important in order to achieve these goals.

  7. Effectiveness of online instruction in the radiologic sciences.

    PubMed

    Johnston, James

    2008-01-01

    Online courses are becoming increasingly common in all academic disciplines and many studies have indicated that there is no significant difference in student outcomes between the 2 instructional methods or, more recently, that online instruction is superior. However, because course content and expectations about mastery of material vary, it is important to evaluate the effectiveness of online courses in different academic disciplines and settings, including radiologic technology. To examine the instructional effectiveness of 2 online radiologic science courses that were converted from a face-to-face instruction format. Archival data were gathered from a sample of convenience (N = 317) to compare 2 years of performance indicators for each course and format. This study also compared course formats in terms of national certification exam results. The results regarding which delivery type performed better were mixed. However, the national certification exam scores for the patient care section were higher for students who completed face-to-face instruction than for those who had online instruction.

  8. Radiology Aide. Instructor's Guide.

    ERIC Educational Resources Information Center

    Hronek, Dennis

    This module was designed to assist educators in facilitating learning in health careers outside nursing. It may be used for classroom, on-the-job, or independent study. The module is oranized in 13 units. Each unit includes one or more lessons that contain the following components: scope of unit, unit objectives; student's information assignment,…

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeremy Gwin and Douglas Frenette

    This document contains process knowledge and radiological data and analysis to support approval for release of the 25-ton locomotive, Serial Number 21547, at the Area 25 Engine Maintenance, Assembly, and Disassembly (EMAD) Facility, located on the Nevada Test Site (NTS). The 25-ton locomotive is a small, one-of-a-kind locomotive used to move railcars in support of the Nuclear Engine for Rocket Vehicle Application project. This locomotive was identified as having significant historical value by the Nevada State Railroad Museum in Boulder City, Nevada, where it will be used as a display piece. A substantial effort to characterize the radiological conditions ofmore » the locomotive was undertaken by the NTS Management and Operations Contractor, National Security Technologies, LLC (NSTec). During this characterization process, seven small areas on the locomotive had contamination levels that exceeded the NTS release criteria (limits consistent with U.S. Department of Energy [DOE] Order DOE O 5400.5, “Radiation Protection of the Public and the Environment”). The decision was made to perform radiological decontamination of these known accessible impacted areas to further the release process. On February 9, 2010, NSTec personnel completed decontamination of these seven areas to within the NTS release criteria. Although all accessible areas of the locomotive had been successfully decontaminated to within NTS release criteria, it was plausible that inaccessible areas of the locomotive (i.e., those areas on the locomotive where it was not possible to perform radiological surveys) could potentially have contamination above unrestricted release limits. To access the majority of these inaccessible areas, the locomotive would have to be disassembled. A complete disassembly for a full radiological survey could have permanently destroyed parts and would have ruined the historical value of the locomotive. Complete disassembly would also add an unreasonable financial burden for the contractor. A decision was reached between the NTS regulator and NSTec, opting for alternative authorized limits from DOE Headquarters. In doing so, NSTec personnel performed a dose model using the DOE-approved modeling code RESRAD-BUILD v3.5 to evaluate scenarios. The parameters used in the dose model were conservative. NSTec’s Radiological Engineering Calculation, REC-2010-001, “Public Dose Estimate from the EMAD 25 Ton Locomotive,” concluded that the four scenarios evaluated were below the 25-millirem per year limit, the “likely” dose scenarios met the “few millirem in a year” criteria, and that the EMAD 25-ton locomotive met the radiological requirements to be released with residual radioactivity to the public.« less

  10. Emergency radiology and mass casualty incidents-report of a mass casualty incident at a level 1 trauma center.

    PubMed

    Bolster, Ferdia; Linnau, Ken; Mitchell, Steve; Roberge, Eric; Nguyen, Quynh; Robinson, Jeffrey; Lehnert, Bruce; Gross, Joel

    2017-02-01

    The aims of this article are to describe the events of a recent mass casualty incident (MCI) at our level 1 trauma center and to describe the radiology response to the event. We also describe the findings and recommendations of our radiology department after-action review. An MCI activation was triggered after an amphibious military vehicle, repurposed for tourist activities, carrying 37 passengers, collided with a charter bus carrying 45 passengers on a busy highway bridge in Seattle, WA, USA. There were 4 deaths at the scene, and 51 patients were transferred to local hospitals following prehospital scene triage. Nineteen patients were transferred to our level 1 trauma center. Eighteen casualties arrived within 72 min. Sixteen arrived within 1 h of the first patient arrival, and 1 casualty was transferred 3 h later having initially been assessed at another hospital. Eighteen casualties (94.7 %) underwent diagnostic imaging in the emergency department. Of these 18 casualties, 15 had a trauma series (portable chest x-ray and x-ray of pelvis). Whole-body trauma computed tomography scans (WBCT) were performed on 15 casualties (78.9 %), 12 were immediate and performed during the initial active phase of the MCI, and 3 WBCTs were delayed. The initial 12 WBCTs were completed in 101 min. The mean number of radiographic studies performed per patient was 3 (range 1-8), and the total number of injuries detected was 88. The surge in imaging requirements during an MCI can be significant and exceed normal operating capacity. This report of our radiology experience during a recent MCI and subsequent after-action review serves to provide an example of how radiology capacity and workflow functioned during an MCI, in order to provide emergency radiologists and response planners with practical recommendations for implementation in the event of a future MCI.

  11. Automatic thoracic body region localization

    NASA Astrophysics Data System (ADS)

    Bai, PeiRui; Udupa, Jayaram K.; Tong, YuBing; Xie, ShiPeng; Torigian, Drew A.

    2017-03-01

    Radiological imaging and image interpretation for clinical decision making are mostly specific to each body region such as head & neck, thorax, abdomen, pelvis, and extremities. For automating image analysis and consistency of results, standardizing definitions of body regions and the various anatomic objects, tissue regions, and zones in them becomes essential. Assuming that a standardized definition of body regions is available, a fundamental early step needed in automated image and object analytics is to automatically trim the given image stack into image volumes exactly satisfying the body region definition. This paper presents a solution to this problem based on the concept of virtual landmarks and evaluates it on whole-body positron emission tomography/computed tomography (PET/CT) scans. The method first selects a (set of) reference object(s), segments it (them) roughly, and identifies virtual landmarks for the object(s). The geometric relationship between these landmarks and the boundary locations of body regions in the craniocaudal direction is then learned through a neural network regressor, and the locations are predicted. Based on low-dose unenhanced CT images of 180 near whole-body PET/CT scans (which includes 34 whole-body PET/CT scans), the mean localization error for the boundaries of superior of thorax (TS) and inferior of thorax (TI), expressed as number of slices (slice spacing ≍ 4mm)), and using either the skeleton or the pleural spaces as reference objects, is found to be 3,2 (using skeleton) and 3, 5 (using pleural spaces) respectively, or in mm 13, 10 mm (using skeleton) and 10.5, 20 mm (using pleural spaces), respectively. Improvements of this performance via optimal selection of objects and virtual landmarks and other object analytics applications are currently being pursued. and the skeleton and pleural spaces used as a reference objects

  12. Improvement of Radiological Teaching - Effects of Focusing of Learning Targets and Increased Consideration of Learning Theory Knowledge.

    PubMed

    Wirth, Stefan; William, York-Alexander; Paolini, Marco; Wirth, Kathrin; Maxien, Daniel; Reiser, Maximilian; Fischer, Martin R

    2018-02-01

     Based on evaluation and examination results of students, a necessity for improvement of so far purely instructor-based radiological teaching at the local institution was determined. Aim of our study was to use one out of eight seminars to exemplify adaptation of the teaching concept according to learning theory knowledge, to determine the resulting effects and to interpret them.  The institutional review board approved the prospective study of the seminar conversion, which was performed after the end of the winter semester 2015/2016. Didactically, this included a course split into online preparation, attendance phase and online follow-up with integration of interactive scaffolding, practice-oriented clinical teaching according to Stanford, Peyton skills transfer and extensive feedback into the attendance phase. At the beginning and at the end of each course, each student filled in identical, standardized questionnaires (n = 256 before and after conversion) using a 5-point Likert scale (1: very good; to 5: deficient) and additionally answered two randomly chosen written examination questions from a content-adapted questionnaire pool of the last five years. For statistical evaluation, the Mann-Whitney U-Test was used for evaluation data and Fisher's Exact test for exam questions.  Before/after conversion, the subjective total evaluation score of students was 3.22 (mean value) ± 1.51 (standard deviation) / 1.66 ± 0.78 (p < 0.001) and the objective proportion of correctly answered examination questions in the respective cohort at the beginning of the seminar 37.7/53.9 % and at the end of the seminar 55.1/84.6 % (p < 0.001).  The conversion of the test seminar resulted in both a better evaluation of the teaching unit by the students (evaluation) and a considerably higher rate of correctly answered examination questions from past state examinations (learning success). This supports transferring the concept to comparable teaching units.   · Radiological teaching allows integration of current learning theory concepts with reasonable effort.. · In a test seminar this improved the evaluation results of the teaching unit by the students.. · In addition, this also led to a higher rate of correctly answered examination questions from past state examinations.. · This supports further steps towards excellent radiological teaching.. · Wirth S, William Y, Paolini M et al. Improvement of Radiological Teaching - Effects of Focusing of Learning Targets and Increased Consideration of Learning Theory Knowledge. Fortschr Röntgenstr 2018; 190: 161 - 174. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Validation of the DIFFAL, HPAC and HotSpot Dispersion Models Using the Full-Scale Radiological Dispersal Device (FSRDD) Field Trials Witness Plate Deposition Dataset.

    PubMed

    Purves, Murray; Parkes, David

    2016-05-01

    Three atmospheric dispersion models--DIFFAL, HPAC, and HotSpot--of differing complexities have been validated against the witness plate deposition dataset taken during the Full-Scale Radiological Dispersal Device (FSRDD) Field Trials. The small-scale nature of these trials in comparison to many other historical radiological dispersion trials provides a unique opportunity to evaluate the near-field performance of the models considered. This paper performs validation of these models using two graphical methods of comparison: deposition contour plots and hotline profile graphs. All of the models tested are assessed to perform well, especially considering that previous model developments and validations have been focused on larger-scale scenarios. Of the models, HPAC generally produced the most accurate results, especially at locations within ∼100 m of GZ. Features present within the observed data, such as hot spots, were not well modeled by any of the codes considered. Additionally, it was found that an increase in the complexity of the meteorological data input to the models did not necessarily lead to an improvement in model accuracy; this is potentially due to the small-scale nature of the trials.

  14. TU-CD-BRA-01: A Novel 3D Registration Method for Multiparametric Radiological Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akhbardeh, A; Parekth, VS; Jacobs, MA

    2015-06-15

    Purpose: Multiparametric and multimodality radiological imaging methods, such as, magnetic resonance imaging(MRI), computed tomography(CT), and positron emission tomography(PET), provide multiple types of tissue contrast and anatomical information for clinical diagnosis. However, these radiological modalities are acquired using very different technical parameters, e.g.,field of view(FOV), matrix size, and scan planes, which, can lead to challenges in registering the different data sets. Therefore, we developed a hybrid registration method based on 3D wavelet transformation and 3D interpolations that performs 3D resampling and rotation of the target radiological images without loss of information Methods: T1-weighted, T2-weighted, diffusion-weighted-imaging(DWI), dynamic-contrast-enhanced(DCE) MRI and PET/CT were usedmore » in the registration algorithm from breast and prostate data at 3T MRI and multimodality(PET/CT) cases. The hybrid registration scheme consists of several steps to reslice and match each modality using a combination of 3D wavelets, interpolations, and affine registration steps. First, orthogonal reslicing is performed to equalize FOV, matrix sizes and the number of slices using wavelet transformation. Second, angular resampling of the target data is performed to match the reference data. Finally, using optimized angles from resampling, 3D registration is performed using similarity transformation(scaling and translation) between the reference and resliced target volume is performed. After registration, the mean-square-error(MSE) and Dice Similarity(DS) between the reference and registered target volumes were calculated. Results: The 3D registration method registered synthetic and clinical data with significant improvement(p<0.05) of overlap between anatomical structures. After transforming and deforming the synthetic data, the MSE and Dice similarity were 0.12 and 0.99. The average improvement of the MSE in breast was 62%(0.27 to 0.10) and prostate was 63%(0.13 to 0.04;p<0.05). The Dice similarity was in breast 8%(0.91 to 0.99) and for prostate was 89%(0.01 to 0.90;p<0.05) Conclusion: Our 3D wavelet hybrid registration approach registered diverse breast and prostate data of different radiological images(MR/PET/CT) with a high accuracy.« less

  15. Application of Analytical Hierarchy Process Approach for Service Quality Evaluation in Radiology Departments: A Cross-Sectional Study.

    PubMed

    Alimohammadzadeh, Khalil; Bahadori, Mohammadkarim; Hassani, Fariba

    2016-01-01

    Radiology department as a service provider organization requires realization of quality concept concerning service provisioning knowledge, satisfaction and all issues relating to the customer as well as quality assurance and improvement issues. At present, radiology departments in hospitals are regarded as income generating units and they should continuously seek performance improvement so that they can survive in the changing and competitive environment of the health care sector. The aim of this study was to propose a method for ranking of radiology departments in selected hospitals of Tehran city using analytical hierarchical process (AHP) and quality evaluation of their service in 2015. This study was an applied and cross-sectional study, carried out in radiology departments of 6 Tehran educational hospitals in 2015. The hospitals were selected using non-probability and purposeful method. Data gathering was performed using customized joint commission international (JCI) standards. Expert Choice 10.0 software was used for data analysis. AHP method was used for prioritization. "Management and empowerment of human resources'' (weight = 0.465) and "requirements and facilities" (weight = 0.139) were of highest and lowest significance respectively in the overall ranking of the hospitals. MS (weight = 0.316), MD (weight = 0.259), AT (weight = 0.14), TS (weight = 0.108), MO (weight = 0.095), and LH (0.082) achieved the first to sixth rankings respectively. The use of AHP method can be promising for fostering the evaluation method and subsequently promotion of the efficiency and effectiveness of the radiology departments. The present model can fill in the gap in the accreditation system of the country's hospitals in respect with ranking and comparing them considering the significance and value of each individual criteria and standard. Accordingly, it can predict an integration of qualitative and quantitative criteria involved and thereby take a decisive step towards further efficiency and effectiveness of the health care evaluation systems.

  16. Detection of pneumonia using free-text radiology reports in the BioSense system.

    PubMed

    Asatryan, Armenak; Benoit, Stephen; Ma, Haobo; English, Roseanne; Elkin, Peter; Tokars, Jerome

    2011-01-01

    Near real-time disease detection using electronic data sources is a public health priority. Detecting pneumonia is particularly important because it is the manifesting disease of several bioterrorism agents as well as a complication of influenza, including avian and novel H1N1 strains. Text radiology reports are available earlier than physician diagnoses and so could be integral to rapid detection of pneumonia. We performed a pilot study to determine which keywords present in text radiology reports are most highly associated with pneumonia diagnosis. Electronic radiology text reports from 11 hospitals from February 1, 2006 through December 31, 2007 were used. We created a computerized algorithm that searched for selected keywords ("airspace disease", "consolidation", "density", "infiltrate", "opacity", and "pneumonia"), differentiated between clinical history and radiographic findings, and accounted for negations and double negations; this algorithm was tested on a sample of 350 radiology reports. We used the algorithm to study 189,246 chest radiographs, searching for the keywords and determining their association with a final International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) diagnosis of pneumonia. Performance of the search algorithm in finding keywords, and association of the keywords with a pneumonia diagnosis. In the sample of 350 radiographs, the search algorithm was highly successful in identifying the selected keywords (sensitivity 98.5%, specificity 100%). Analysis of the 189,246 radiographs showed that the keyword "pneumonia" was the strongest predictor of an ICD-9-CM diagnosis of pneumonia (adjusted odds ratio 11.8) while "density" was the weakest (adjusted odds ratio 1.5). In general, the most highly associated keyword present in the report, regardless of whether a less highly associated keyword was also present, was the best predictor of a diagnosis of pneumonia. Empirical methods may assist in finding radiology report keywords that are most highly predictive of a pneumonia diagnosis. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  17. Terminology and reporting criteria for radiofrequency ablation of tumors in the scientific literature: systematic review of compliance with reporting standards.

    PubMed

    Kang, Tae Wook; Rhim, Hyunchul; Lee, Min Woo; Kim, Young-sun; Choi, Dongil; Lim, Hyo Keun

    2014-01-01

    To perform a systematic review of compliance with standardized terminology and reporting criteria for radiofrequency (RF) tumor ablation, proposed by the International Working Group on Image-Guided Tumor Ablation in 2003, in the published reports. Literature search in the PubMed database was performed using index keywords, PubMed limit system, and eligibility criteria. The entire content of each article was reviewed to assess the terminology used for procedure terms, imaging findings, therapeutic efficacy, follow-up, and complications. Accuracy of the terminology and the use of alternative terms instead of standard terminology were analyzed. In addition, disparities in accuracy of terminology in articles according to the medical specialty and the type of radiology journal were evaluated. Among the articles (n = 308) included in this study, the accuracy of the terms 'procedure or session', 'treatment', 'index tumor', 'ablation zone', 'technical success', 'primary technique effectiveness rate', 'secondary technique effectiveness rate', 'local tumor progression', 'major complication', and 'minor complication' was 97% (298/307), 97% (291/300), 8% (25/307), 65% (103/159), 55% (52/94), 33% (42/129), 94% (17/18), 45% (88/195), 99% (79/80), and 100% (77/77), respectively. The overall accuracy of each term showed a tendency to improve over the years. The most commonly used alternative terms for 'technical success' and 'local tumor progression' were 'complete ablation' and 'local (tumor) recurrence', respectively. The accuracy of terminology in articles published in radiology journals was significantly greater than that of terminology in articles published in non-radiology journals, especially in Radiology and The Journal of Vascular and Interventional Radiology. The proposal for standardization of terminology and reporting criteria for RF tumor ablation has been gaining support according to the recently published scientific reports, especially in the field of radiology. However, more work is still needed for the complete standardization of terminology.

  18. [Bladder pseudotumor in childhood].

    PubMed

    Fernández Arjona, M; Muñoz-Delgado Salmerón, J; Shihadei, S; Colomar, P J; García Estevez, J A

    1997-01-01

    Case report of a 10 year-old male with vesical mass suggestive of a rabdomiosarcoma based on the radiologic studies performed. The existence of an inflammatory process with no signs of malignancy was confirmed by transurethral resection. The serological studies were negative and the absence of malignant disease in further substantiated by immunohistochemistry. We want to emphasize that certain vesical masses. which appear to be malignant on the radiological study (Pseudotumours), may be just inflammatory processes.

  19. Is past academic productivity predictive of radiology resident academic productivity?

    PubMed

    Patterson, Stephanie K; Fitzgerald, James T; Boyse, Tedric D; Cohan, Richard H

    2002-02-01

    The authors performed this study to determine whether academic productivity in college and medical school is predictive of the number of publications produced during radiology residency. The authors reviewed the records of 73 radiology residents who completed their residency from 1990 to 2000. Academic productivity during college, medical school, and radiology residency, other postgraduate degrees, and past careers other than radiology were tabulated. The personal essay attached to the residency application was reviewed for any stated academic interest. Residents were classified as being either previously productive or previously unproductive. Publication rates during residency and immediately after residency were compared for the two groups. For the productive residents, a correlation analysis was used to examine the relationship between past frequency of publication and type of previous activity. Least-squares regression analysis was used to investigate the relationship between preresidency academic productivity, advanced degrees, stated interest in academics, and other careers and radiology residency publications. There was no statistically significant difference in the number of articles published by those residents who were active and those who were not active before residency (P = .21). Only authorship of papers as an undergraduate was weakly predictive of residency publication. These selected measures of academic productivity as an undergraduate and during medical school are not helpful for predicting publication during residency. There was no difference in publication potential between those residents who were academically productive in the past and those who were not.

  20. E-learning and education in radiology.

    PubMed

    Pinto, Antonio; Brunese, Luca; Pinto, Fabio; Acampora, Ciro; Romano, Luigia

    2011-06-01

    To evaluate current applications of e-learning in radiology. A Medline search was performed using PubMed (National Library of Medicine, Bethesda, MD) for publications discussing the applications of e-learning in radiology. The search strategy employed a single combination of the following terms: (1) e-learning, and (2) education and (3) radiology. This review was limited to human studies and to English-language literature. We reviewed all the titles and subsequent the abstract of 29 articles that appeared pertinent. Additional articles were identified by reviewing the reference lists of relevant papers. Finally, the full text of 38 selected articles was reviewed. Literature data shows that with the constant development of technology and global spread of computer networks, in particular of the Internet, the integration of multimedia and interactivity introduced into electronic publishing has allowed the creation of multimedia applications that provide valuable support for medical teaching and continuing medical education, specifically for radiology. Such technologies are valuable tools for collaboration, interactivity, simulation, and self-testing. However, not everything on the World Wide Web is useful, accurate, or beneficial: the quality and veracity of medical information on the World Wide Web is variable and much time can be wasted as many websites do not meet basic publication standards. E-learning will become an important source of education in radiology. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  1. A diagnostic model for chronic hypersensitivity pneumonitis

    PubMed Central

    Johannson, Kerri A; Elicker, Brett M; Vittinghoff, Eric; Assayag, Deborah; de Boer, Kaïssa; Golden, Jeffrey A; Jones, Kirk D; King, Talmadge E; Koth, Laura L; Lee, Joyce S; Ley, Brett; Wolters, Paul J; Collard, Harold R

    2017-01-01

    The objective of this study was to develop a diagnostic model that allows for a highly specific diagnosis of chronic hypersensitivity pneumonitis using clinical and radiological variables alone. Chronic hypersensitivity pneumonitis and other interstitial lung disease cases were retrospectively identified from a longitudinal database. High-resolution CT scans were blindly scored for radiographic features (eg, ground-glass opacity, mosaic perfusion) as well as the radiologist’s diagnostic impression. Candidate models were developed then evaluated using clinical and radiographic variables and assessed by the cross-validated C-statistic. Forty-four chronic hypersensitivity pneumonitis and eighty other interstitial lung disease cases were identified. Two models were selected based on their statistical performance, clinical applicability and face validity. Key model variables included age, down feather and/or bird exposure, radiographic presence of ground-glass opacity and mosaic perfusion and moderate or high confidence in the radiographic impression of chronic hypersensitivity pneumonitis. Models were internally validated with good performance, and cut-off values were established that resulted in high specificity for a diagnosis of chronic hypersensitivity pneumonitis. PMID:27245779

  2. Shapelet analysis of pupil dilation for modeling visuo-cognitive behavior in screening mammography

    NASA Astrophysics Data System (ADS)

    Alamudun, Folami; Yoon, Hong-Jun; Hammond, Tracy; Hudson, Kathy; Morin-Ducote, Garnetta; Tourassi, Georgia

    2016-03-01

    Our objective is to improve understanding of visuo-cognitive behavior in screening mammography under clinically equivalent experimental conditions. To this end, we examined pupillometric data, acquired using a head-mounted eye-tracking device, from 10 image readers (three breast-imaging radiologists and seven Radiology residents), and their corresponding diagnostic decisions for 100 screening mammograms. The corpus of mammograms comprised cases of varied pathology and breast parenchymal density. We investigated the relationship between pupillometric fluctuations, experienced by an image reader during mammographic screening, indicative of changes in mental workload, the pathological characteristics of a mammographic case, and the image readers' diagnostic decision and overall task performance. To answer these questions, we extract features from pupillometric data, and additionally applied time series shapelet analysis to extract discriminative patterns in changes in pupil dilation. Our results show that pupillometric measures are adequate predictors of mammographic case pathology, and image readers' diagnostic decision and performance with an average accuracy of 80%.

  3. Correlation between thigh pain and radiological findings with a proximally porous-coated stem.

    PubMed

    Kinov, Plamen; Radl, Roman; Zacherl, Maximilian; Leithner, Andreas; Windhager, Reinhard

    2007-10-01

    Thigh pain has been consistently reported with cementless hip arthroplasty. The correlation between thigh pain and radiological findings and the clinical significance of thigh pain have not been studied in any detail. We carried out a retrospective study to analyse the performance of a proximally porous-coated cementless femoral component. Ninety-eight total hip arthroplasties were followed up clinically and radiologically for an average of 33 months (range: 12 to 64) after operation. The clinical results were good or excellent in 85 cases (87%). Thirteen patients (13%) reported thigh pain at latest follow-up. Subsidence of the stem was recorded in 10 cases, cortical thickening occurred in 14 hips (14%), and 17 hips (17%) presented proximal osteopenia. Proximally, radiolucent lines were observed in 11 cases. Thigh pain correlated with radiolucent lines, femoral thickening, fibrous fixation and stem migration. Bone remodelling was noted to continue even five years after implantation. Our observations demonstrated bone ingrowth in the majority of the cases and a low incidence of thigh pain. The correlation between radiological changes and thigh pain suggests implant micromotion and migration in some hips. Patients with thigh pain, changes in the proximal femur and progressive subsidence need further clinical and radiological follow-up.

  4. Coagulation necrosis induced by radiofrequency ablation in the liver: histopathologic and radiologic review of usual to extremely rare changes.

    PubMed

    Kim, Young-sun; Rhim, Hyunchul; Lim, Hyo Keun; Choi, Dongil; Lee, Min Woo; Park, Min Jung

    2011-01-01

    As the clinical role of radiofrequency ablation (RFA) of the liver grows, the importance of radiologic imaging after liver RFA to depict the diversity of post-RFA manifestations is also increasing. Because RFA induces coagulation necrosis of the hepatic parenchyma, cross-sectional imaging studies, in principle, demonstrate an area with a defect in contrast enhancement. However, for various reasons, such as the occurrence of a complication, the RFA zone may demonstrate different patterns or be accompanied by other abnormalities. In this investigation, a large number of imaging studies performed after more than 4000 procedures of liver RFA during the past 10-year period were reviewed, and various radiologic manifestations of the RFA zone were compiled. Herein, the basic principles of RFA, as well as the histopathologic features of coagulation necrosis of the liver, are catalogued to provide a more complete understanding of such changes. Through this review, the reader will become more familiar with the usual and unusual radiologic findings of coagulation necrosis induced by RFA in the liver. This increased familiarity will not only facilitate the daily practice of radiology but also deepen understanding of the therapeutic modality of RFA. © RSNA, 2011.

  5. Selected accounts receivable performance statistics for radiology practices: an analysis of the adjusted collection percentage and days charges in accounts receivable.

    PubMed

    Cergnul, John J; Russell, Philip J; Sunshine, Jonathan H

    2005-12-01

    To provide comparative data and analysis with respect to accounts receivable management performance criteria. Data from 3 sources were analyzed: the Radiology Business Management Association's (RBMA) 2003 Accounts Receivable Performance Survey; the RBMA's 2003 Accounts Receivable Survey; and Hogan and Sunshine's 2004 Radiology article "Financial Ratios in Diagnostic Radiology Practices: Variability and Trends," the data for which were drawn primarily from the ACR's 1999 Survey of Practices. The RBMA surveyed (via e-mail and postal mail) only its members, with response rates of 15% and 9%, respectively. The ACR's survey response rate was 66%, via postal mail, and was distributed without regard to the RBMA membership status of the practice manager or even whether the practice employed a practice manager. Comparison among the survey results provided information on trends. Median practice professional component adjusted collection percentage (ACP) deteriorated from 87.3% to 85.1% between the RBMA surveys. Practices limited to global fee billing faired much better when performing their billing in house, as opposed to using a billing service, with mean ACPs of 91.2% and 79.4%, respectively. Days charges in accounts receivable 2004 mean results for professional component billing and global fee billing were nearly identical at 56.11 and 55.54 days, respectively. The 2003 RBMA survey reported 63.74 days for professional component billing and 77.33 days for global fee billing. The improvement from 2003 to 2004 was highly significant for both professional component billing and global fee billing. The 2004 RBMA survey also reflected a rather dramatic improvement in days charges in accounts receivable compared with Hogan and Sunshine's results, which showed a mean of 69 days charges in accounts receivable. The conflicting trends between ACP performance and days charges in accounts receivable performance may be explained by the increasing sophistication of accounts receivable management processes (improving days charges in accounts receivable) and the deterioration in the general economy between survey periods (decreasing ACPs). Additionally, generally better accounts receivable management performance was experienced by practices employing RBMA members (RBMA survey participants) compared with those that may or may not have employed RBMA members (ACR survey participants).

  6. SU-C-18C-06: Radiation Dose Reduction in Body Interventional Radiology: Clinical Results Utilizing a New Imaging Acquisition and Processing Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kohlbrenner, R; Kolli, KP; Taylor, A

    2014-06-01

    Purpose: To quantify the patient radiation dose reduction achieved during transarterial chemoembolization (TACE) procedures performed in a body interventional radiology suite equipped with the Philips Allura Clarity imaging acquisition and processing platform, compared to TACE procedures performed in the same suite equipped with the Philips Allura Xper platform. Methods: Total fluoroscopy time, cumulative dose area product, and cumulative air kerma were recorded for the first 25 TACE procedures performed to treat hepatocellular carcinoma (HCC) in a Philips body interventional radiology suite equipped with Philips Allura Clarity. The same data were collected for the prior 85 TACE procedures performed to treatmore » HCC in the same suite equipped with Philips Allura Xper. Mean values from these cohorts were compared using two-tailed t tests. Results: Following installation of the Philips Allura Clarity platform, a 42.8% reduction in mean cumulative dose area product (3033.2 versus 1733.6 mGycm∧2, p < 0.0001) and a 31.2% reduction in mean cumulative air kerma (1445.4 versus 994.2 mGy, p < 0.001) was achieved compared to similar procedures performed in the same suite equipped with the Philips Allura Xper platform. Mean total fluoroscopy time was not significantly different between the two cohorts (1679.3 versus 1791.3 seconds, p = 0.41). Conclusion: This study demonstrates a significant patient radiation dose reduction during TACE procedures performed to treat HCC after a body interventional radiology suite was converted to the Philips Allura Clarity platform from the Philips Allura Xper platform. Future work will focus on evaluation of patient dose reduction in a larger cohort of patients across a broader range of procedures and in specific populations, including obese patients and pediatric patients, and comparison of image quality between the two platforms. Funding for this study was provided by Philips Healthcare, with 5% salary support provided to authors K. Pallav Kolli and Robert G. Gould for time devoted to the study. Data acquisition and analysis was performed by the authors independent of the funding source.« less

  7. Variability in the Use of Simulation for Procedural Training in Radiology Residency: Opportunities for Improvement.

    PubMed

    Matalon, Shanna A; Chikarmane, Sona A; Yeh, Eren D; Smith, Stacy E; Mayo-Smith, William W; Giess, Catherine S

    2018-03-19

    Increased attention to quality and safety has led to a re-evaluation of the classic apprenticeship model for procedural training. Many have proposed simulation as a supplementary teaching tool. The purpose of this study was to assess radiology resident exposure to procedural training and procedural simulation. An IRB-exempt online survey was distributed to current radiology residents in the United States by e-mail. Survey results were summarized using frequency and percentages. Chi-square tests were used for statistical analysis where appropriate. A total of 353 current residents completed the survey. 37% (n = 129/353) of respondents had never used procedure simulation. Of the residents who had used simulation, most did not do so until after having already performed procedures on patients (59%, n = 132/223). The presence of a dedicated simulation center was reported by over half of residents (56%, n = 196/353) and was associated with prior simulation experience (P = 0.007). Residents who had not had procedural simulation were somewhat likely or highly likely (3 and 4 on a 4-point Likert-scale) to participate if it were available (81%, n = 104/129). Simulation training was associated with higher comfort levels in performing procedures (P < 0.001). Although procedural simulation training is associated with higher comfort levels when performing procedures, there is variable use in radiology resident training and its use is not currently optimized. Given the increased emphasis on patient safety, these results suggest the need to increase procedural simulation use during residency, including an earlier introduction to simulation before patient exposure. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Barriers and facilitators to adoption of soft copy interpretation from the user perspective: Lessons learned from filmless radiology for slideless pathology

    PubMed Central

    Patterson, Emily S.; Rayo, Mike; Gill, Carolina; Gurcan, Metin N.

    2011-01-01

    Background: Adoption of digital images for pathological specimens has been slower than adoption of digital images in radiology, despite a number of anticipated advantages for digital images in pathology. In this paper, we explore the factors that might explain this slower rate of adoption. Materials and Method: Semi-structured interviews on barriers and facilitators to the adoption of digital images were conducted with two radiologists, three pathologists, and one pathologist's assistant. Results: Barriers and facilitators to adoption of digital images were reported in the areas of performance, workflow-efficiency, infrastructure, integration with other software, and exposure to digital images. The primary difference between the settings was that performance with the use of digital images as compared to the traditional method was perceived to be higher in radiology and lower in pathology. Additionally, exposure to digital images was higher in radiology than pathology, with some radiologists exclusively having been trained and/or practicing with digital images. The integration of digital images both improved and reduced efficiency in routine and non-routine workflow patterns in both settings, and was variable across the different organizations. A comparison of these findings with prior research on adoption of other health information technologies suggests that the barriers to adoption of digital images in pathology are relatively tractable. Conclusions: Improving performance using digital images in pathology would likely accelerate adoption of innovative technologies that are facilitated by the use of digital images, such as electronic imaging databases, electronic health records, double reading for challenging cases, and computer-aided diagnostic systems. PMID:21383925

  9. Comparison Between Manual Auditing and a Natural Language Process With Machine Learning Algorithm to Evaluate Faculty Use of Standardized Reports in Radiology.

    PubMed

    Guimaraes, Carolina V; Grzeszczuk, Robert; Bisset, George S; Donnelly, Lane F

    2018-03-01

    When implementing or monitoring department-sanctioned standardized radiology reports, feedback about individual faculty performance has been shown to be a useful driver of faculty compliance. Most commonly, these data are derived from manual audit, which can be both time-consuming and subject to sampling error. The purpose of this study was to evaluate whether a software program using natural language processing and machine learning could accurately audit radiologist compliance with the use of standardized reports compared with performed manual audits. Radiology reports from a 1-month period were loaded into such a software program, and faculty compliance with use of standardized reports was calculated. For that same period, manual audits were performed (25 reports audited for each of 42 faculty members). The mean compliance rates calculated by automated auditing were then compared with the confidence interval of the mean rate by manual audit. The mean compliance rate for use of standardized reports as determined by manual audit was 91.2% with a confidence interval between 89.3% and 92.8%. The mean compliance rate calculated by automated auditing was 92.0%, within that confidence interval. This study shows that by use of natural language processing and machine learning algorithms, an automated analysis can accurately define whether reports are compliant with use of standardized report templates and language, compared with manual audits. This may avoid significant labor costs related to conducting the manual auditing process. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Occupational radiation exposure in vascular interventional radiology: A complete evaluation of different body regions.

    PubMed

    Bacchim Neto, Fernando Antonio; Alves, Allan Felipe Fattori; Mascarenhas, Yvone Maria; Nicolucci, Patrícia; Pina, Diana Rodrigues de

    2016-08-01

    To perform a complete evaluation on radiation doses, received by primary and assistant medical staff, while performing different vascular interventional radiology procedures. We evaluated dose received in different body regions during three categories of vascular procedures: lower limb angiography (Angiography), lower limb percutaneous transluminal angioplasty (Angioplasty) and stent graft placement for abdominal aortic aneurysm treatment (A. A. A. Treatment). We positioned the dosimeters near the eye lens, thyroid, chest, abdomen, hands, and feet of the interventional physicians. Equivalent dose was compared with annual dose limits for workers in order to determine the maximum number of procedures per year that each physician could perform. We assessed 90 procedures. We found the highest equivalent doses in the A. A. A. Treatment, in which 90% of the evaluations indicated at least one region receiving more than 1mSv per procedure. Angioplasty was the only procedural modality that provided statistically different doses for different professionals, which is an important aspect on regards to radiological protection strategies. In comparison with the dose limits, the most critical region in all procedures was the eye lens. Since each body region of the interventionist is exposed to different radiation levels, dose distribution measurements are essential for radiological protection strategies. These results indicate that dosimeters placed in abdomen instead of chest may represent more accurately the whole body doses received by the medical staff. Additional dosimeters and a stationary shield for the eye lens are strongly recommended. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. Evaluation of two selection tests for recruitment into radiology specialty training.

    PubMed

    Patterson, Fiona; Knight, Alec; McKnight, Liam; Booth, Thomas C

    2016-07-11

    This study evaluated whether two selection tests previously validated for primary care General Practice (GP) trainee selection could provide a valid shortlisting selection method for entry into specialty training for the secondary care specialty of radiology. We conducted a retrospective analysis of data from radiology applicants who also applied to UK GP specialty training or Core Medical Training. The psychometric properties of the two selection tests, a clinical problem solving (CPS) test and situational judgement test (SJT), were analysed to evaluate their reliability. Predictive validity of the tests was analysed by comparing them with the current radiology selection assessments, and the licensure examination results taken after the first stage of training (Fellowship of the Royal College of Radiologists (FRCR) Part 1). The internal reliability of the two selection tests in the radiology applicant sample was good (α ≥ 0.80). The average correlation with radiology shortlisting selection scores was r = 0.26 for the CPS (with p < 0.05 in 5 of 11 shortlisting centres), r = 0.15 for the SJT (with p < 0.05 in 2 of 11 shortlisting centres) and r = 0.25 (with p < 0.05 in 5 of 11 shortlisting centres) for the two tests combined. The CPS test scores significantly correlated with performance in both components of the FRCR Part 1 examinations (r = 0.5 anatomy; r = 0.4 physics; p < 0.05 for both). The SJT did not correlate with either component of the examination. The current CPS test may be an appropriate selection method for shortlisting in radiology but would benefit from further refinement for use in radiology to ensure that the test specification is relevant. The evidence on whether the SJT may be appropriate for shortlisting in radiology is limited. However, these results may be expected to some extent since the SJT is designed to measure non-academic attributes. Further validation work (e.g. with non-academic outcome variables) is required to evaluate whether an SJT will add value in recruitment for radiology specialty training and will further inform construct validity of SJTs as a selection methodology.

  12. Who will be the Radiologists of Tomorrow? A survey of radiology during the "Practical Year" in Germany.

    PubMed

    Dettmer, Sabine; Fischer, Volkhard; Paeßens, Carolin; Meyer, Simone; Wacker, Frank K; Rodt, Thomas

    2017-10-01

    Purpose  Aim of our study was to evaluate the motivation of medical students in their final year of medical school to choose radiology for further specialization by means of a Germany-wide survey. Materials and Methods  The survey was performed during the 2015/16 semester among German medical students in their four months radiology elective during the final year. Invitations for the study were distributed by the Student Secretariats of each university. The survey was web-based with EvaSys 7.0 software. Questions on radiology contents during medical studies and "practical year" were part of the survey. Plans for residency and possible advantages and disadvantages of radiology as medical specialty were inquired. Descriptive statistics and group comparisons were used as analysis methods. Results  89 students participated in the survey at the beginning and 60 students at the end of the practical year. Of these 39 students could be identified who answered both questionnaires. Most students were satisfied with their final year radiology elective (mean 1.8 on a range from 1 to 5). Nevertheless, they criticized mentoring during routine work (mean 2.1) and a lack of educational courses (mean 2.1). Most students (83 %) were uncertain about their residency choice at the beginning of their "practical year" and about one fifth changed their plans. From the students' point of view main advantages of radiology included contact with many other clinical disciplines (87 %) and the working conditions (68 %). The reduced patient contact (42 %), the large amount of work at a computer (43 %), and the dependency on referring physicians (42 %) were regarded as the main disadvantages. The students regarded the way radiology is taught during the studies as not practical enough. With regard to radiology the majority of students (63 %) felt poorly prepared for their future work. Conclusion  The "practical year" is important regarding the choice of future specialization. There was a high degree of satisfaction with the "practical year" in radiology. The mentoring during routine work and a lack of educational courses was mildly criticized. These factors provide room for improvement to foster students' interest in radiology. Key Points   · The "practical year" is important regarding the choice of further specialization.. · Criticisms of radiology in the "practical year" were mentoring and courses.. · Students feel poorly prepared for their future work regarding practical radiological skills.. Citation Format · Dettmer S, Fischer V, Paeßens C et al. Who will be the Radiologists of Tomorrow? A survey of radiology during the "Practical Year" in Germany. Fortschr Röntgenstr 2017; 189: 967 - 976. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Closure Report for Corrective Action Unit 539: Areas 25 and 26 Railroad Tracks Nevada National Security Site, Nevada with ROTC-1, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mark Kauss

    2011-06-01

    This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 539: Areas 25 and 26 Railroad Tracks, Nevada National Security Site, Nevada. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management. The corrective action sites (CASs) within CAU 539 are located within Areas 25 and 26 of the Nevada National Security Site. Corrective Action Unit 539 comprises the following CASs: • 25-99-21, Area 25 Railroad Tracksmore » • 26-99-05, Area 26 Railroad Tracks The purpose of this CR is to provide documentation supporting the completed corrective actions and provide data confirming that the closure objectives for CASs within CAU 539 were met. To achieve this, the following actions were performed: • Reviewed documentation on historical and current site conditions, including the concentration and extent of contamination. • Conducted radiological walkover surveys of railroad tracks in both Areas 25 and 26. • Collected ballast and soil samples and calculated internal dose estimates for radiological releases. • Collected in situ thermoluminescent dosimeter measurements and calculated external dose estimates for radiological releases. • Removed lead bricks as potential source material (PSM) and collected verification samples. • Implemented corrective actions as necessary to protect human health and the environment. • Properly disposed of corrective action and investigation wastes. • Implemented an FFACO use restriction (UR) for radiological contamination at CAS 25-99-21. The approved UR form and map are provided in Appendix F and will be filed in the DOE, National Nuclear Security Administration Nevada Site Office (NNSA/NSO), Facility Information Management System; the FFACO database; and the NNSA/NSO CAU/CAS files. From November 29, 2010, through May 2, 2011, closure activities were performed as set forth in the Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 539: Areas 25 and 26 Railroad Tracks, Nevada Test Site, Nevada. The purposes of the activities as defined during the data quality objectives process were as follows: • Determine whether contaminants of concern (COCs) are present. • If COCs are present, determine their nature and extent, implement appropriate corrective actions, and properly dispose of wastes. Analytes detected during the closure activities were evaluated against final action levels (FALs) to determine COCs for CAU 539. Assessment of the data generated from closure activities revealed the following: • At CAS 26-99-05, the total effective dose for radiological releases did not exceed the FAL of 25 millirem per Industrial Area year. Potential source material in the form of lead bricks was found at three locations. A corrective action of clean closure was implemented at these locations, and verification samples indicated that no further action is necessary. • At CAS 25-99-21, the total effective dose for radiological releases exceeds the FAL of 25 millirem per Industrial Area year. Potential source material in the form of lead bricks was found at eight locations. A corrective action was implemented by removing the lead bricks and soil above FALs at these locations, and verification samples indicated that no further action is necessary. Pieces of debris with high radioactivity were identified as PSM and remain within the CAS boundary. A corrective action of closure in place with a UR was implemented at this CAS because closure activities showed evidence of remaining soil contamination and radioactive PSM. Future land use will be restricted from surface and intrusive activities. Closure activities generated waste streams consisting of industrial solid waste, recyclable materials, low-level radioactive waste, and mixed low-level radioactive waste. Wastes were disposed of in the appropriate onsite landfills. The NNSA/NSO provides the following recommendations: • Clean closure is required at CAS 26-99-05. • Closure in place is required at CAS 25-99-21. • A UR is required at CAS 25-99-21. • A Notice of Completion to the NNSA/NSO is requested from the Nevada Division of Environmental Protection for closure of CAU 539. • Corrective Action Unit 539 should be moved from Appendix III to Appendix IV of the FFACO.« less

  14. Utility of Interobserver Agreement Statistics in Establishing Radiology Resident Learning Curves During Self-directed Radiologic Anatomy Training.

    PubMed

    Tureli, Derya; Altas, Hilal; Cengic, Ismet; Ekinci, Gazanfer; Baltacioglu, Feyyaz

    2015-10-01

    The aim of the study was to ascertain the learning curves for the radiology residents when first introduced to an anatomic structure in magnetic resonance images (MRI) to which they have not been previously exposed to. The iliolumbar ligament is a good marker for testing learning curves of radiology residents because the ligament is not part of a routine lumbar MRI reporting and has high variability in detection. Four radiologists, three residents without previous training and one mentor, studied standard axial T1- and T2-weighted images of routine lumbar MRI examinations. Radiologists had to define iliolumbar ligament while blinded to each other's findings. Interobserver agreement analyses, namely Cohen and Fleiss κ statistics, were performed for groups of 20 cases to evaluate the self-learning curve of radiology residents. Mean κ values of resident-mentor pairs were 0.431, 0.608, 0.604, 0.826, and 0.963 in the analysis of successive groups (P < .001). The results indicate that the concordance between the experienced and inexperienced radiologists started as weak (κ <0.5) and gradually became very acceptable (κ >0.8). Therefore, a junior radiology resident can obtain enough experience in identifying a rather ambiguous anatomic structure in routine MRI after a brief instruction of a few minutes by a mentor and studying approximately 80 cases by oneself. Implementing this methodology will help radiology educators obtain more concrete ideas on the optimal time and effort required for supported self-directed visual learning processes in resident education. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  15. Managing a Multisite Academic-Private Radiology Practice Reading Environment: Impact of IT Downtimes on Enterprise Efficiency.

    PubMed

    Becker, Murray; Goldszal, Alberto; Detal, Julie; Gronlund-Jacob, Judith; Epstein, Robert

    2015-06-01

    The aim of this study was to assess whether the complex radiology IT infrastructures needed for large, geographically diversified, radiology practices are inherently stable with respect to system downtimes, and to characterize the nature of the downtimes to better understand their impact on radiology department workflow. All radiology IT unplanned downtimes over a 12-month period in a hybrid academic-private practice that performs all interpretations in-house (no commercial "nighthawk" services) for approximately 900,000 studies per year, originating at 6 hospitals, 10 outpatient imaging centers, and multiple low-volume off-hours sites, were logged and characterized using 5 downtime metrics: duration, etiology, failure type, extent, and severity. In 12 consecutive months, 117 unplanned downtimes occurred with the following characteristics: duration: median time = 3.5 hours with 34% <1.5 hours and 30% >12 hours; etiology: 87% were due to software malfunctions, and 13% to hardware malfunctions; failure type: 88% were transient component failures, 12% were complete component failures; extent: all sites experienced downtimes, but downtimes were always localized to a subset of sites, and no system-wide downtimes occurred; severity (impact on radiologist workflow): 47% had minimal impact, 50% moderate impact, and 3% severe impact. In the complex radiology IT system that was studied, downtimes were common; they were usually a result of transient software malfunctions; the geographic extent was always localized rather than system wide; and most often, the impacts on radiologist workflow were modest. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. A Combined Pharmacokinetic and Radiologic Assessment of Dynamic Contrast-Enhanced Magnetic Resonance Imaging Predicts Response to Chemoradiation in Locally Advanced Cervical Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Semple, Scott; Harry, Vanessa N. MRCOG.; Parkin, David E.

    2009-10-01

    Purpose: To investigate the combination of pharmacokinetic and radiologic assessment of dynamic contrast-enhanced magnetic resonance imaging (MRI) as an early response indicator in women receiving chemoradiation for advanced cervical cancer. Methods and Materials: Twenty women with locally advanced cervical cancer were included in a prospective cohort study. Dynamic contrast-enhanced MRI was carried out before chemoradiation, after 2 weeks of therapy, and at the conclusion of therapy using a 1.5-T MRI scanner. Radiologic assessment of uptake parameters was obtained from resultant intensity curves. Pharmacokinetic analysis using a multicompartment model was also performed. General linear modeling was used to combine radiologic andmore » pharmacokinetic parameters and correlated with eventual response as determined by change in MRI tumor size and conventional clinical response. A subgroup of 11 women underwent repeat pretherapy MRI to test pharmacokinetic reproducibility. Results: Pretherapy radiologic parameters and pharmacokinetic K{sup trans} correlated with response (p < 0.01). General linear modeling demonstrated that a combination of radiologic and pharmacokinetic assessments before therapy was able to predict more than 88% of variance of response. Reproducibility of pharmacokinetic modeling was confirmed. Conclusions: A combination of radiologic assessment with pharmacokinetic modeling applied to dynamic MRI before the start of chemoradiation improves the predictive power of either by more than 20%. The potential improvements in therapy response prediction using this type of combined analysis of dynamic contrast-enhanced MRI may aid in the development of more individualized, effective therapy regimens for this patient group.« less

  17. Improving Novice Radiology Trainees' Perception Using Fine Art.

    PubMed

    Goodman, Thomas Rob; Kelleher, Michael

    2017-10-01

    To determine if fine art perception training improved performance in novice radiology trainees. On the first day of their residency, 15 radiology residents underwent a basic radiology perception test in which they were shown 15 different radiographs that each had a significant abnormality. This was followed by a focused session of interpretation training at a local art gallery where art experts taught the trainees how to thoroughly analyze a painting. After this fine art session, the residents were once again shown 15 different radiographs and asked, in the same manner as before, to identify the location of the abnormality. The results of both radiograph assessments were then compared. The 15 residents correctly identified the areas of abnormality on 35 of 225 cases pre-art training with a mean score of 2.33 and a SD of 1.4. After art training, the figure for correctly identifying the area of abnormality rose to 94 of 225 cases with a mean score of 6.27 and a SD of 1.79 (P < .0001). The implementation of a focused teaching session on perception improved first-year residents' ability to localize imaging abnormalities. This improvement was significant (P < .0001). Most errors in radiology occur due to failures of perception rather than failures to correctly interpret a finding and, as such, it behooves the profession to ensure that perception training is adequately addressed as part of a radiology training curriculum. Using an art gallery may be a novel, effective transitional starting point for novice radiology trainees. Copyright © 2017. Published by Elsevier Inc.

  18. [Quality of life and job performance resulting from operatively treated tibial plateau fractures].

    PubMed

    Roßbach, B P; Faymonville, C; Müller, L P; Stützer, H; Isenberg, J

    2016-01-01

    The aim of this article is to present the functional results and the effect on quality of life of surgically treated tibial plateau fractures in physically active and working patients with multiple and serious injuries. In addition, the relationships between functional and radiological outcome were evaluated and compared with activity in daily and professional life. In all, 41 injured patients were followed up a mean of 47 months after surgical treatment and examined with radiological, functional, as well as quality of life score. In the radiological scoring, a mean value of 72 points (max 100 points) was achieved. In the activity score, there was an average of 63.5 points (max 100 points). When evaluating the health-related quality of life, an average score of 69.6 points was achieved. There was a significant relationship between radiological and activity scores and the radiological and life quality scores. Furthermore, the relationship between activity and quality of life scores was considered significant. Surgeon's influence on the functional outcome could be confirmed. The functional and the radiological results were moderate. Quality of life was permanently affected by the consequences of tibial plateau fracture in 12 patients; 11 patients were not re-employed. However, the quality of life was assessed as good or very good and 28 patients had returned to work. The quality of life was firmly linked to the radiological and functional parameters, which tended to be influenced by the quality of the primary surgical treatment when looking at the overall population.

  19. Medical errors arising from outsourcing laboratory and radiology services.

    PubMed

    Chasin, Brian S; Elliott, Sean P; Klotz, Stephen A

    2007-09-01

    Document errors and the nuisance factor inherent in the informational exchange that occurs with the outsourcing of laboratory and radiology examinations. Three infectious diseases physicians at a tertiary care hospital recorded problems involving data transmitted by telephone or fax from outsource providers for 4 months. This included in- and outpatients, and those in transition from one status to another. Outsourcing laboratory and radiology examinations of insured outpatients is a common practice. Insurance companies determine which healthcare facility performs these tests based on contractual agreements with outsource providers. This leads to confusion and frustration for the doctor and patient alike, and occasionally, to medical error. The exchange of patient data involved in outsourcing is subject to systemic errors that do not allow of easy solution.

  20. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.

  1. Definition of Local Diagnostic Reference Levels in a Radiology Department Using a Dose Tracking Software.

    PubMed

    Ghetti, C; Ortenzia, O; Palleri, F; Sireus, M

    2017-06-01

    Dose optimization in radiological examinations is a mandatory issue: in this study local Diagnostic Reference Levels (lDRLs) for Clinical Mammography (MG), Computed Tomography (CT) and Interventional Cardiac Procedures (ICP) performed in our Radiology Department were established. Using a dose tracking software, we have collected Average Glandular Dose (AGD) for two clinical mammographic units; CTDIvol, Size-Specific Dose Estimate (SSDE), Dose Length Product (DLP) and total DLP (DLPtot) for five CT scanners; Fluoro Time, Fluoro Dose Area Product (DAP) and total DAP (DAPtot) for two angiographic systems. Data have been compared with Italian Regulation and with the recent literature. The 75th percentiles of the different dosimetric indices have been calculated. Automated methods of radiation dose data collection allow a fast and detailed analysis of a great amount of data and an easy determination of lDRLs for different radiological procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Decision support systems for clinical radiological practice — towards the next generation

    PubMed Central

    Stivaros, S M; Gledson, A; Nenadic, G; Zeng, X-J; Keane, J; Jackson, A

    2010-01-01

    The huge amount of information that needs to be assimilated in order to keep pace with the continued advances in modern medical practice can form an insurmountable obstacle to the individual clinician. Within radiology, the recent development of quantitative imaging techniques, such as perfusion imaging, and the development of imaging-based biomarkers in modern therapeutic assessment has highlighted the need for computer systems to provide the radiological community with support for academic as well as clinical/translational applications. This article provides an overview of the underlying design and functionality of radiological decision support systems with examples tracing the development and evolution of such systems over the past 40 years. More importantly, we discuss the specific design, performance and usage characteristics that previous systems have highlighted as being necessary for clinical uptake and routine use. Additionally, we have identified particular failings in our current methodologies for data dissemination within the medical domain that must be overcome if the next generation of decision support systems is to be implemented successfully. PMID:20965900

  3. Spontaneous resolution of traumatic acute subdural haematomas: A systematic review.

    PubMed

    Vital, Roberto Bezerra; Hamamoto Filho, Pedro Tadao; Oliveira, Victor Azevedo de; Romero, Flávio Ramalho; Zanini, Marco Antônio

    2016-01-01

    Traumatic subdural haematomas often require emergency surgical evacuation. Spontaneous resolution of traumatic acute subdural haematomas (TASDH) is under-reported. Two patients are described with spontaneous resolution of TASDH correlating with previous reports. A discussion is presented on the clinical, pathological and radiological features of TASDH. A review of the literature was performed using PubMed (Medline), Embase, and Cochrane Library for similar cases. A total 21 articles were included, involving 27 cases well detailed of TASDH with spontaneous resolution or neurological and radiological improvement in less than 24 h. There are two main mechanisms for the spontaneous resolution of acute subdural haematomas: dilution in subarachnoid space and redistribution of the haematoma in the subdural space. The primary radiological characteristic of these lesions is a hypodense rim on the outer surface of the clot. Spontaneous resolution of TASDH is unusual. Clinical and radiological surveillance is essential for appropriate management of these patients. Copyright © 2015 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  4. An analysis of nursing diagnoses for patients undergoing procedures in a Brazilian interventional radiology suite.

    PubMed

    Viegas, Liza de Souza; Turrini, Ruth Natalia Teresa; da Silva Bastos Cerullo, Josinete Aparecida

    2010-05-01

    Innovations in minimally invasive surgery have led to more procedures being performed in the interventional radiology suite. It, therefore, is essential that nurses in radiology departments be competent to care for all types of patients. Use of nursing classification systems can improve care by providing standardized language for documentation. We conducted a project that involved 25 patients undergoing interventional radiology procedures between August and October 2006 in São Paulo, Brazil, to identify the most frequent North American Nursing Diagnosis Association (NANDA) nursing diagnoses used and then compared the NANDA diagnoses to Perioperative Nursing Data Set diagnoses. The most frequent nursing diagnoses in the participants were anxiety, chronic pain, inefficient tissue perfusion-peripheral, deficient knowledge, and risk for falls. These results are similar to diagnoses that have been reported in outpatient centers. The NANDA and Perioperative Nursing Data Set diagnoses were found to be similar. Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  5. Enterprise imaging: planning and business justification.

    PubMed

    Avrin, David; Hou, Stephanie W

    2012-02-01

    To evaluate financial performance, academic radiology departments most often measure examination volume and general technical and professional expenses. Although these metrics are not standardized, their frequency of use reflects that productivity and financial health are high priorities for academic radiology departments across the United States. In this article, we discuss both of these topics, in the context of projects to expand services, particularly those with an information technology (IT) component. First, we discuss several informatics innovations that increase productivity or expand service. Second, we explain core financial analysis concepts applicable to radiology departments. Third, we discuss the unique challenge of evaluating a potential IT project for an academic radiology department, when intangible benefits are difficult to quantify. Financial models are only one of several components used for guidance in strategic decisions, but are crucial to building a business case that justifies the initial or capital investment as well as startup and ongoing operational expenses. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  6. Structuring Cooperative Nuclear RIsk Reduction Initiatives with China.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brandt, Larry; Reinhardt, Jason Christian; Hecker, Siegfried

    The Stanford Center for International Security and Cooperation engaged several Chinese nuclear organizations in cooperative research that focused on responses to radiological and nuclear terrorism. The objective was to identify joint research initiatives to reduce the global dangers of such threats and to pursue initial technical collaborations in several high priority areas. Initiatives were identified in three primary research areas: 1) detection and interdiction of smuggled nuclear materials; 2) nuclear forensics; and 3) radiological (“dirty bomb”) threats and countermeasures. Initial work emphasized the application of systems and risk analysis tools, which proved effective in structuring the collaborations. The extensive engagementsmore » between national security nuclear experts in China and the U.S. during the research strengthened professional relationships between these important communities.« less

  7. Development, implementation, and evaluation of a structured reporting web tool for abdominal aortic aneurysms.

    PubMed

    Karim, Sulafa; Fegeler, Christian; Boeckler, Dittmar; H Schwartz, Lawrence; Kauczor, Hans-Ulrich; von Tengg-Kobligk, Hendrik

    2013-08-16

    The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. A Web-based application for radiological "structured reporting" (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems.

  8. Characterisation of an anthropomorphic chest phantom for dose measurements in radiology beams

    NASA Astrophysics Data System (ADS)

    Henriques, L. M. S.; Cerqueira, R. A. D.; Santos, W. S.; Pereira, A. J. S.; Rodrigues, T. M. A.; Carvalho Júnior, A. B.; Maia, A. F.

    2014-02-01

    The objective of this study was to characterise an anthropomorphic chest phantom for dosimetric measurements of conventional radiology beams. This phantom was developed by a previous research project at the Federal University of Sergipe for image quality control tests. As the phantom consists of tissue-equivalent material, it is possible to characterise it for dosimetric studies. For comparison, a geometric chest phantom, consisting of PMMA (polymethylmethacrylate) with dimensions of 30×30×15 cm³ was used. Measurements of incident air kerma (Ki) and entrance surface dose (ESD) were performed using ionisation chambers. From the results, backscatter factors (BSFs) of the two phantoms were determined and compared with values estimated by CALDose_X software, based on a Monte Carlo simulation. For the technical parameters evaluated in this study, the ESD and BSF values obtained experimentally showed a good similarity between the two phantoms, with minimum and maximum difference of 0.2% and 7.0%, respectively, and showed good agreement with the results published in the literature. Organ doses and effective doses for the anthropomorphic phantom were also estimated by the determination of conversion coefficients (CCs) using the visual Monte Carlo (VMC) code. Therefore, the results of this study prove that the anthropomorphic thorax phantom proposed is a good tool to use in dosimetry and can be used for risk evaluation of X-ray diagnostic procedures.

  9. British Society of Interventional Radiology: Biliary Drainage and Stenting Registry (BDSR)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uberoi, R., E-mail: raman.uberoi@orh.nhs.uk; Das, N.; Moss, J.

    Objectives: This study was designed to audit current practice in percutaneous biliary drainage and stenting in the United Kingdom. Methods: In 2006, the British Society of Interventional Radiology set up the first web-based Biliary Drainage and Stenting Registry (BDSR). This consisted of a series of tick sheets, which were completed online. Data collection included technical and clinical success of the procedures and outcomes at discharge with a separate form for any follow-up visits. Two months before data analysis, all contributors were asked via email to complete any outstanding data. This paper reports on data collected between November 1, 2006 andmore » August 18, 2009. Results: A total of 833 procedures were recorded and were entered by 62 operators from 44 institutions within the United Kingdom. There were 455 men and 378 women with a median age of 69 (range 20-101) years.The majority of procedures were performed by a consultant. Successful drainage of the biliary tree was achieved in 98.7%. Partial or complete relief of symptoms was seen in 65% of patients. Minor complications, predominantly pain (14.3%), were seen in 26% and major complications, predominantly sepsis (3.5%), were seen in 7.9% of patients. Conclusions: These figures provide an essential benchmark for both audit and patient information. Identifying areas of good practice and those that require improvement will ultimately result in better patient care.« less

  10. Reduction of metal artifacts from alloy hip prostheses in computer tomography.

    PubMed

    Wang, Fengdan; Xue, Huadan; Yang, Xianda; Han, Wei; Qi, Bing; Fan, Yu; Qian, Wenwei; Wu, Zhihong; Zhang, Yan; Jin, Zhengyu

    2014-01-01

    The objective of this study was to evaluate the feasibility of reducing artifacts from large metal implants with gemstone spectral imaging (GSI) and metal artifact reduction software (MARS). Twenty-three in-vivo cobalt-chromium-molybdenum alloy total hip prostheses were prospectively scanned by fast kV-switching GSI between 80 and 140 kVp. The computed tomography images were reconstructed with monochromatic energy and with/without MARS. Both subjective and objective measurements were performed to assess the severity of metal artifacts. Increasing photon energy was associated with reduced metal artifacts in GSI images (P < 0.001). Combination of GSI with MARS further diminished the metal artifacts (P < 0.001). Artifact reduction at 3 anatomical levels (femoral head, neck, and shaft) were evaluated, with data showing that GSI and MARS could reduce metal artifacts at all 3 levels (P = 0.011, P < 0.001, and P = 0.003, respectively). Nevertheless, in certain cases, GSI without MARS produced more realistic images for the clinical situation. Proper usage of GSI with/without MARS could reduce the computed tomography artifacts of large metal parts and improve the radiological evaluation of postarthroplasty patients.

  11. Embedded importance watermarking for image verification in radiology

    NASA Astrophysics Data System (ADS)

    Osborne, Domininc; Rogers, D.; Sorell, M.; Abbott, Derek

    2004-03-01

    Digital medical images used in radiology are quite different to everyday continuous tone images. Radiology images require that all detailed diagnostic information can be extracted, which traditionally constrains digital medical images to be of large size and stored without loss of information. In order to transmit diagnostic images over a narrowband wireless communication link for remote diagnosis, lossy compression schemes must be used. This involves discarding detailed information and compressing the data, making it more susceptible to error. The loss of image detail and incidental degradation occurring during transmission have potential legal accountability issues, especially in the case of the null diagnosis of a tumor. The work proposed here investigates techniques for verifying the voracity of medical images - in particular, detailing the use of embedded watermarking as an objective means to ensure that important parts of the medical image can be verified. We propose a result to show how embedded watermarking can be used to differentiate contextual from detailed information. The type of images that will be used include spiral hairline fractures and small tumors, which contain the essential diagnostic high spatial frequency information.

  12. Benefits of an automatic patient dose registry system for interventional radiology and cardiology at five hospitals of the Madrid area.

    PubMed

    Fernandez-Soto, J M; Ten, J I; Sanchez, R M; España, M; Pifarre, X; Vano, E

    2015-07-01

    The purpose of this article is to present the results of connecting the interventional radiology and cardiology laboratories of five university hospitals to a unique server using an automatic patient dose registry system (Dose On Line for Interventional Radiology, DOLIR) developed in-house, and to evaluate its feasibility more than a year after its introduction. The system receives and stores demographic and dosimetric parameters included in the MPPS DICOM objects sent by the modalities to a database. A web service provides a graphical interface to analyse the information received. During 2013, the system processed 10 788 procedures (6874 cardiac, 2906 vascular and 1008 neuro interventional). The percentages of patients requiring clinical follow-up due to potential tissue reactions before and after the use of DOLIR are presented. The system allowed users to verify in real-time, if diagnostic (or interventional) reference levels are fulfilled. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Validation of Case Finding Algorithms for Hepatocellular Cancer from Administrative Data and Electronic Health Records using Natural Language Processing

    PubMed Central

    Sada, Yvonne; Hou, Jason; Richardson, Peter; El-Serag, Hashem; Davila, Jessica

    2013-01-01

    Background Accurate identification of hepatocellular cancer (HCC) cases from automated data is needed for efficient and valid quality improvement initiatives and research. We validated HCC ICD-9 codes, and evaluated whether natural language processing (NLP) by the Automated Retrieval Console (ARC) for document classification improves HCC identification. Methods We identified a cohort of patients with ICD-9 codes for HCC during 2005–2010 from Veterans Affairs administrative data. Pathology and radiology reports were reviewed to confirm HCC. The positive predictive value (PPV), sensitivity, and specificity of ICD-9 codes were calculated. A split validation study of pathology and radiology reports was performed to develop and validate ARC algorithms. Reports were manually classified as diagnostic of HCC or not. ARC generated document classification algorithms using the Clinical Text Analysis and Knowledge Extraction System. ARC performance was compared to manual classification. PPV, sensitivity, and specificity of ARC were calculated. Results 1138 patients with HCC were identified by ICD-9 codes. Based on manual review, 773 had HCC. The HCC ICD-9 code algorithm had a PPV of 0.67, sensitivity of 0.95, and specificity of 0.93. For a random subset of 619 patients, we identified 471 pathology reports for 323 patients and 943 radiology reports for 557 patients. The pathology ARC algorithm had PPV of 0.96, sensitivity of 0.96, and specificity of 0.97. The radiology ARC algorithm had PPV of 0.75, sensitivity of 0.94, and specificity of 0.68. Conclusion A combined approach of ICD-9 codes and NLP of pathology and radiology reports improves HCC case identification in automated data. PMID:23929403

  14. Validation of Case Finding Algorithms for Hepatocellular Cancer From Administrative Data and Electronic Health Records Using Natural Language Processing.

    PubMed

    Sada, Yvonne; Hou, Jason; Richardson, Peter; El-Serag, Hashem; Davila, Jessica

    2016-02-01

    Accurate identification of hepatocellular cancer (HCC) cases from automated data is needed for efficient and valid quality improvement initiatives and research. We validated HCC International Classification of Diseases, 9th Revision (ICD-9) codes, and evaluated whether natural language processing by the Automated Retrieval Console (ARC) for document classification improves HCC identification. We identified a cohort of patients with ICD-9 codes for HCC during 2005-2010 from Veterans Affairs administrative data. Pathology and radiology reports were reviewed to confirm HCC. The positive predictive value (PPV), sensitivity, and specificity of ICD-9 codes were calculated. A split validation study of pathology and radiology reports was performed to develop and validate ARC algorithms. Reports were manually classified as diagnostic of HCC or not. ARC generated document classification algorithms using the Clinical Text Analysis and Knowledge Extraction System. ARC performance was compared with manual classification. PPV, sensitivity, and specificity of ARC were calculated. A total of 1138 patients with HCC were identified by ICD-9 codes. On the basis of manual review, 773 had HCC. The HCC ICD-9 code algorithm had a PPV of 0.67, sensitivity of 0.95, and specificity of 0.93. For a random subset of 619 patients, we identified 471 pathology reports for 323 patients and 943 radiology reports for 557 patients. The pathology ARC algorithm had PPV of 0.96, sensitivity of 0.96, and specificity of 0.97. The radiology ARC algorithm had PPV of 0.75, sensitivity of 0.94, and specificity of 0.68. A combined approach of ICD-9 codes and natural language processing of pathology and radiology reports improves HCC case identification in automated data.

  15. A Diagnostic Dilemma for the Pediatrician: Radiolucent Tracheobronchial Foreign Body.

    PubMed

    Taşkınlar, Hakan; Bahadır, Gökhan Berktuğ; Erdoğan, Cankat; Yiğit, Doğakan; Avlan, Dinçer; Naycı, Ali

    2017-06-01

    The purpose of this study is to determine the role of clinical history, physical examinations, and radiological findings in the evaluation of patients with suspected radiolucent foreign body aspiration. The medical records of 236 children (under the age of 18 years), on whom a rigid bronchoscopy was performed between 1999 and 2015 because of suspected radiolucent foreign body aspiration, were analyzed retrospectively. Sensitivity, specificity, positive and negative predictive values of clinical history, physical examinations, and radiological findings were evaluated. In 71.1% of all cases, the children were under the age of 3 years. The bronchoscopy showed the presence of a foreign body in 52.9% of cases, with the locations of the foreign bodies being as follows: (1) right main bronchus, 47.2%; (2) left main bronchus, 36.0%; (3) trachea, 11.2%; (4) both bronchi, 5.6%. Organic foreign bodies were found in 78% of the patients, whereas inorganic foreign bodies were detected in 22% of the patients. The sensitivity and specificity of clinical history, physical examinations, and radiological findings were 98.4% and 54.9%, 47.2% and 74.7%, and 35.2% and 92.7%, respectively. Tracheobronchial foreign body aspirations usually occur prior to the age of 3 years, with the most frequently aspirated foreign bodies being food or items of a radiolucent nature. Clinical history, physical examinations, and radiological findings are not able to detect the presence of a radiolucent foreign body aspiration in children. Therefore, a bronchoscopy should be performed on children in whom a choking event has been witnessed, even in cases of normal radiological and clinical findings. Copyright © 2016. Published by Elsevier B.V.

  16. A Low-Cost Tele-Imaging Platform for Developing Countries

    PubMed Central

    Adambounou, Kokou; Adjenou, Victor; Salam, Alex P.; Farin, Fabien; N’Dakena, Koffi Gilbert; Gbeassor, Messanvi; Arbeille, Philippe

    2014-01-01

    Purpose: To design a “low-cost” tele-imaging method allowing real-time tele-ultrasound expertise, delayed tele-ultrasound diagnosis, and tele-radiology between remote peripherals hospitals and clinics (patient centers) and university hospital centers (expert center). Materials and methods: A system of communication via internet (IP camera and remote access software) enabling transfer of ultrasound videos and images between two centers allows a real-time tele-radiology expertise in the presence of a junior sonographer or radiologist at the patient center. In the absence of a sonographer or radiologist at the patient center, a 3D reconstruction program allows a delayed tele-ultrasound diagnosis with images acquired by a lay operator (e.g., midwife, nurse, technician). The system was tested both with high and low bandwidth. The system can further accommodate non-ultrasound tele-radiology (conventional radiography, mammography, and computer tomography for example). The system was tested on 50 patients between CHR Tsevie in Togo (40 km from Lomé-Togo and 4500 km from Tours-France) and CHU Campus at Lomé and CHU Trousseau in Tours. Results: A real-time tele-expertise was successfully performed with a delay of approximately 1.5 s with an internet bandwidth of around 1 Mbps (IP Camera) and 512 kbps (remote access software). A delayed tele-ultrasound diagnosis was also performed with satisfactory results. The transmission of radiological images from the patient center to the expert center was of adequate quality. Delayed tele-ultrasound and tele-radiology was possible even in the presence of a low-bandwidth internet connection. Conclusion: This tele-imaging method, requiring nothing by readily available and inexpensive technology and equipment, offers a major opportunity for telemedicine in developing countries. PMID:25250306

  17. Honorary authorship in radiologic research articles: assessment of frequency and associated factors.

    PubMed

    Eisenberg, Ronald L; Ngo, Long; Boiselle, Philip M; Bankier, Alexander A

    2011-05-01

    To quantify the frequency of perceived honorary authorship in radiologic journals and to identify specific factors that increase its prevalence. This study qualified for exempt status by the institutional review board. An electronic survey was sent to first authors of all original research articles published in Radiology and European Radiology over 3 years. Questions included guidelines used for determining authorship, contributions of coauthors, the perception of honorary authorship, and demographic information. Univariable analysis of sample proportions was performed by using χ(2) tests. Multivariable logistic regression models were used to assess the independent factors that were associated with the probability of perceiving honorary authorship. Of the 392 (29.3%) of 1338 first authors who responded to the survey, 102 (26.0%) perceived that one or more coauthors did not make sufficient contributions to merit being included as an author. Of the 392 respondents, 231 (58.9%) stated that one or more coauthors performed only "nonauthor" tasks according to International Committee of Medical Journal Editors criteria. Factors associated with an increased first-author perception of honorary authorship included lower academic rank (adjusted odds ratio [OR]: 2.89; 95% confidence interval [CI]: 1.66, 5.06), as well as working in an environment in which the section or department head was automatically listed as an author (adjusted OR: 3.80; 95% CI: 2.13, 6.79). The percentage of honorary authorship was significantly higher (P = .019) among respondents who did not follow journal requirements for authorship. The rate of perceived honorary authorship (overall, 26.0%) was substantially more frequent among respondents of lower academic rank and in those working in an environment in which their section or department head was automatically listed as an author. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101500/-/DC1. RSNA, 2011

  18. Cutting costs: the impact of price lists on the cost development at the emergency department.

    PubMed

    Schilling, Ulf Martin

    2010-12-01

    It was shown that physicians working at the Swedish emergency department (ED) are unaware of the costs for investigations performed. This study evaluated the possible impact of price lists on the overall laboratory and radiology costs at the ED of a Swedish university hospital. Price lists including the most common laboratory analyses and radiological investigations at the ED were created. The lists were distributed to all internal medicine physicians by e-mail and exposed above their working stations continually. No lists were provided for the orthopaedic control group. The average costs for laboratory and radiological investigations during the months of June and July 2007 and 2008 were calculated. Neither clinical nor admission procedures were changed. The physicians were blinded towards the study. Statistical analysis was performed using the Student's t-test. A total of 1442 orthopaedic and 1585 medical patients were attended to in 2007. In 2008, 1467 orthopaedic and 1637 medical patients required emergency service. The average costs per patient were 980.27 SKR (98€)/999.41 SKR (100€, +1.95%) for orthopaedic and 1081.36 SKR (108€)/877.3 SKR (88€, -18.8%) for medical patients. Laboratory costs decreased by 9% in orthopaedic and 21.4% in medical patients. Radiology costs changed +5.4% in orthopaedic and -20.59% in medical patients. The distribution and promotion of price lists as a tool at the ED to heighten cost awareness resulted in a major decrease in the investigation costs. A significant decrease in radiological costs could be observed. It can be concluded that price lists are an effective tool to cut costs in public healthcare.

  19. Modelling a radiology department service using a VDL integrated approach.

    PubMed

    Guglielmino, Maria Gabriella; Celano, Giovanni; Costa, Antonio; Fichera, Sergio

    2009-01-01

    The healthcare industry is facing several challenges such as the reduction of costs and quality improvement of the provided services. Engineering studies could be very useful in supporting organizational and management processes. Healthcare service efficiency depends on a strong collaboration between clinical and engineering experts, especially when it comes to analyzing the system and its constraints in detail and subsequently, when it comes to deciding on the reengineering of some key activities. The purpose of this paper is to propose a case study showing how a mix of representation tools allow a manager of a radiology department to solve some human and technological resource re-organizational issues, which have to be faced due to the introduction of a new technology and a new portfolio of services. In order to simulate the activities within the radiology department and examine the relationship between human and technological resources, different visual diagrammatic language (VDL) techniques have been implemented to get knowledge about the heterogeneous factors related to the healthcare service delivery. In particular, flow charts, IDEFO diagrams and Petri nets have been integrated each other with success as a modelisation tools. The simulation study performed through the application of the aforementioned VDL techniques suggests the opportunity of re-organizing the nurse activities within the radiology department. The re-organization of a healthcare service and in particular of a radiology department by means of joint flow charts, IDEF0 diagrams and Petri nets is a poorly investigated topic in literature. This paper demonstrates how flow charts and IDEF0 can help people working within the department to understand the weak points of their organization and constitute an efficient base of knowledge for the implementation of a Petri net aimed at improving the departmental performance.

  20. Home-based radiology transcription and a productivity pay plan.

    PubMed

    Kerr, K

    1997-01-01

    Shands Hospital in Gainesville, Fla., decided to evaluate the way it provided transcription services in its radiology department. It identified four goals: increased productivity, decreased operating expense, finding much needed space in the radiology department and increasing employee morale. The department performs 165,000 procedures annually, with 66 radiologists, 29 faculty, and 37 residents and fellows on staff. Six FTEs comprised the transcription pool in the radiology department, with transcription their only duty. Transcriptionists were paid an hourly rate based on their years of service, not their productivity. Evaluation and measurement studies were undertaken by the hospital's management systems engineering department. The transcriptionists' hours were then changed to provide coverage during the periods of heaviest dictation. The productivity level of the transcription staff was also measured and various methods of measurement reviewed. The goal was a pure incentive pay plan that would reward employees for every increase in productivity. The incentive pay plan was phased in over a three-month period. Transcriptionists were paid for work performed, with no base pay beyond minimum wage. The move to home-based transcription was planned. The necessary equipment was identified and various issues specific to working at home were addressed. Approximately six months later, the transcriptionists were set up to work at home. The astounding results achieved are presented: 28% increase in productivity, operational cost savings exceeding $25,000 and a space savings of 238 square feet.

Top