Wirth, S; Klodt, C; Wintermeyer, P; Berrang, J; Hensel, K; Langer, T; Heusch, A
2014-09-01
To perform a prospective, blinded, randomized interventional trial in patients with recurrent abdominal pain. The primary endpoint was to determine the abdominal pain intensity after 2 weeks of fructose restricted diet. Secondary endpoints were changes of pain frequency and a secondary symptom score (SSS). 103 individuals with recurrent abdominal pain for more than 3 months were randomized. 51 patients were allocated to group A (diet) and 52 to group B (no diet). 2 weeks later the patients underwent hydrogen breath test and were assigned to the test positive or negative group to identify patients with fructose malabsorption. 2 weeks after intervention the pain score decreased significantly from a median 5.5 in group A to 4 and did not change significantly in group B (5.3 to 5). In group A both patients with positive and negative breath tests had a significant lower pain score (-2 and -1.75, respectively). Frequency of abdominal pain decreased in both groups but without significant difference, SSS improved only in group A from median 6 to 3.5. Positive breath test was no predicting factor, neither was abdominal pain during the test. Fructose restricted diet in children and adolescents with recurrent abdominal pain may be of benefit to improve both abdominal pain symptoms and other secondary symptoms. Since a negative breath test result does not exclude a positive response to fructose restriction, the hydrogen breath test does not seem to be the appropriate diagnostic mean to predict the response to the diet. © Georg Thieme Verlag KG Stuttgart · New York.
How to deal with morning bad breath: A randomized, crossover clinical trial.
Oliveira-Neto, Jeronimo M; Sato, Sandra; Pedrazzi, Vinícius
2013-11-01
The absence of a protocol for the treatment of halitosis has led us to compare mouthrinses with mechanical oral hygiene procedures for treating morning breath by employing a hand-held sulfide monitor. To compare the efficacy of five modalities of treatment for controlling morning halitosis in subjects with no dental or periodontal disease. This is a five-period, randomized, crossover clinical trial. Twenty volunteers were randomly assigned to the trial. Testing involved the use of a conventional tongue scraper, a tongue scraper joined to the back of a toothbrush's head, two mouthrinses (0.05% cetylpyridinium chloride and 0.12% chlorhexidine digluconate) and a soft-bristled toothbrush and fluoride toothpaste for practicing oral hygiene. Data analysis was performed using SPSS version 17 for Windows and NCSS 2007 software (P < 0.05). The products and the periods were compared with each other using the Friedman's test. When significant differences (P < 0.05) were determined, the products and periods were compared in pairs by using the Wilcoxon's test and by adjusting the original significance level (0.05) for multiple comparisons by using the Bonferroni's method. The toothbrush's tongue scraper was able to significantly reduce bad breath for up to 2 h. Chlorhexidine reduced bad breath only at the end of the second hour, an effect that lasted for 3 h. Mechanical tongue cleaning was able to immediately reduce bad breath for a short period, whereas chlorhexidine and mechanical oral hygiene reduced bad breath for longer periods, achieving the best results against morning breath.
How to deal with morning bad breath: A randomized, crossover clinical trial
Oliveira-Neto, Jeronimo M.; Sato, Sandra; Pedrazzi, Vinícius
2013-01-01
Context: The absence of a protocol for the treatment of halitosis has led us to compare mouthrinses with mechanical oral hygiene procedures for treating morning breath by employing a hand-held sulfide monitor. Aims: To compare the efficacy of five modalities of treatment for controlling morning halitosis in subjects with no dental or periodontal disease. Settings and Design: This is a five-period, randomized, crossover clinical trial. Materials and Methods: Twenty volunteers were randomly assigned to the trial. Testing involved the use of a conventional tongue scraper, a tongue scraper joined to the back of a toothbrush's head, two mouthrinses (0.05% cetylpyridinium chloride and 0.12% chlorhexidine digluconate) and a soft-bristled toothbrush and fluoride toothpaste for practicing oral hygiene. Statistical Analysis Used: Data analysis was performed using SPSS version 17 for Windows and NCSS 2007 software (P < 0.05). The products and the periods were compared with each other using the Friedman's test. When significant differences (P < 0.05) were determined, the products and periods were compared in pairs by using the Wilcoxon's test and by adjusting the original significance level (0.05) for multiple comparisons by using the Bonferroni's method. Results: The toothbrush's tongue scraper was able to significantly reduce bad breath for up to 2 h. Chlorhexidine reduced bad breath only at the end of the second hour, an effect that lasted for 3 h. Conclusions: Mechanical tongue cleaning was able to immediately reduce bad breath for a short period, whereas chlorhexidine and mechanical oral hygiene reduced bad breath for longer periods, achieving the best results against morning breath. PMID:24554886
Code of Federal Regulations, 2014 CFR
2014-01-01
... as indicated by an evidential breath test under subpart F of this part. (d) Alcohol use means the... paragraph (i) of this section). For purposes of pre-employment testing only, the term “covered employee... for random drug testing means the number of verified positive results for random drug tests conducted...
Code of Federal Regulations, 2013 CFR
2013-01-01
... as indicated by an evidential breath test under subpart F of this part. (d) Alcohol use means the... paragraph (i) of this section). For purposes of pre-employment testing only, the term “covered employee... for random drug testing means the number of verified positive results for random drug tests conducted...
Code of Federal Regulations, 2011 CFR
2011-01-01
... as indicated by an evidential breath test under subpart F of this part. (d) Alcohol use means the... paragraph (i) of this section). For purposes of pre-employment testing only, the term “covered employee... for random drug testing means the number of verified positive results for random drug tests conducted...
Code of Federal Regulations, 2012 CFR
2012-01-01
... as indicated by an evidential breath test under subpart F of this part. (d) Alcohol use means the... paragraph (i) of this section). For purposes of pre-employment testing only, the term “covered employee... for random drug testing means the number of verified positive results for random drug tests conducted...
Chang, Matthew S; Minaya, Maria T; Cheng, Jianfeng; Connor, Bradley A; Lewis, Suzanne K; Green, Peter H R
2011-10-01
Small intestinal bacterial overgrowth (SIBO) is one cause of a poor response to a gluten-free diet (GFD) and persistent symptoms in celiac disease. Rifaximin has been reported to improve symptoms in non-controlled trials. To determine the effect of rifaximin on gastrointestinal symptoms and lactulose-hydrogen breath tests in patients with poorly responsive celiac disease. A single-center, double-blind, randomized, controlled trial of patients with biopsy-proven celiac disease and persistent gastrointestinal symptoms despite a GFD was conducted. Patients were randomized to placebo (n = 25) or rifaximin (n = 25) 1,200 mg daily for 10 days. They completed the Gastrointestinal Symptom Rating Scale (GSRS) and underwent lactulose-hydrogen breath tests at weeks 0, 2, and 12. An abnormal breath test was defined as: (1) a rise in hydrogen of ≥20 parts per million (ppm) within 100 min, or (2) two peaks ≥20 ppm over baseline. GSRS scores were unaffected by treatment with rifaximin, regardless of baseline breath tests. In a multivariable regression model, the duration of patients' gastrointestinal symptoms significantly predicted their overall GSRS scores (estimate 0.029, p < 0.006). According to criteria 1 and 2, respectively, SIBO was present in 55 and 8% of patients at baseline, intermittently present in 28 and 20% given placebo, and 28 and 12% given rifaximin. There was no difference in the prevalence of SIBO between placebo and treatment groups at weeks 2 and 12. Rifaximin does not improve patients' reporting of gastrointestinal symptoms and hydrogen breath tests do not reliably identify who will respond to antibiotic therapy.
Measurement of fatigue following 18 msw dry chamber dives breathing air or enriched air nitrox.
Harris, R J D; Doolette, D J; Wilkinson, D C; Williams, D J
2003-01-01
Many divers report less fatigue following diving breathing oxygen rich N2-O2 mixtures compared with breathing air. In this double blinded, randomized controlled study 11 divers breathed either air or Enriched Air Nitrox 36% (oxygen 36%, nitrogen 64%) during an 18 msw (281 kPa(a)) dry chamber dive for a bottom time of 40 minutes. Two periods of exercise were performed during the dive. Divers were assessed before and after each dive using the Multidimensional Fatigue Inventory-20, a visual analogue scale, Digit Span Tests, Stroop Tests, and Divers Health Survey (DHS). Diving to 18m produced no measurable difference in fatigue, attention levels, ability to concentrate or DHS scores, following dives using either breathing gas.
Souday, Vincent; Koning, Nick J; Perez, Bruno; Grelon, Fabien; Mercat, Alain; Boer, Christa; Seegers, Valérie; Radermacher, Peter; Asfar, Pierre
2016-01-01
To test the hypothesis whether enriched air nitrox (EAN) breathing during simulated diving reduces decompression stress when compared to compressed air breathing as assessed by intravascular bubble formation after decompression. Human volunteers underwent a first simulated dive breathing compressed air to include subjects prone to post-decompression venous gas bubbling. Twelve subjects prone to bubbling underwent a double-blind, randomized, cross-over trial including one simulated dive breathing compressed air, and one dive breathing EAN (36% O2) in a hyperbaric chamber, with identical diving profiles (28 msw for 55 minutes). Intravascular bubble formation was assessed after decompression using pulmonary artery pulsed Doppler. Twelve subjects showing high bubble production were included for the cross-over trial, and all completed the experimental protocol. In the randomized protocol, EAN significantly reduced the bubble score at all time points (cumulative bubble scores: 1 [0-3.5] vs. 8 [4.5-10]; P < 0.001). Three decompression incidents, all presenting as cutaneous itching, occurred in the air versus zero in the EAN group (P = 0.217). Weak correlations were observed between bubble scores and age or body mass index, respectively. EAN breathing markedly reduces venous gas bubble emboli after decompression in volunteers selected for susceptibility for intravascular bubble formation. When using similar diving profiles and avoiding oxygen toxicity limits, EAN increases safety of diving as compared to compressed air breathing. ISRCTN 31681480.
Cosci, Fiammetta; Anna Aldi, Giulia; Nardi, Antonio Egidio
2015-09-30
Distress tolerance has been operationalized as task persistence in stressful behavioral laboratory tasks. According to the distress tolerance perspective, how an individual responds to discomfort/distress predicts early smoking lapses. This theory seems weakly supported by experimental studies since they are limited in number, show inconsistent results, do not include control conditions. We tested the response to a stressful task in smokers under abstinence and under no abstinence to verify if tobacco abstinence reduces task persistence, thus distress tolerance. A placebo-controlled, double-blind, randomized, cross-over design was used. Twenty smokers underwent a breath holding test after the administration of nicotine on one test day and a placebo on another test day. Physiological and psychological variables were assessed at baseline and directly before and after each challenge. Abstinence induced a statistically significant shorter breath holding duration relative to the nicotine condition. No different response to the breath holding test was observed when nicotine and placebo conditions were compared. No response to the breath holding test was found when pre- and post-test values of heart rate, blood pressure, Visual Analogue Scale for fear or discomfort were compared. In brief, tobacco abstinence reduces breath holding duration but breath holding test does not influence discomfort. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Nonaka, Takashi; Kessoku, Takaomi; Ogawa, Yuji; Yanagisawa, Shogo; Shiba, Tadahiko; Sahaguchi, Takashi; Atsukawa, Kazuhiro; Takahashi, Hisao; Sekino, Yusuke; Iida, Hiroshi; Hosono, Kunihiro; Endo, Hiroki; Sakamoto, Yasunari; Koide, Tomoko; Takahashi, Hirokazu; Tokoro, Chikako; Abe, Yasunobu; Maeda, Shin; Nakajima, Atsushi; Inamori, Masahiko
2011-01-01
The aim of this study was to determine whether oral Itopride hydrochloride (itopride) intake might have any effect on the rate of gastric emptying, using a novel non-invasive technique for measuring the rate of gastric emptying, namely, the continuous real time 13C breath test (BreathID system: Exalenz Bioscience Ltd., Israel). Eight healthy male volunteers participated in this randomized, two-way crossover study. The subjects fasted overnight and were randomly assigned to receive 50mg itopride following a test meal (200 kcal per 200mL, containing 100mg 13C acetate), or the test meal alone. Under both conditions, gastric emptying was monitored for 4 hours after administration of the test meal by the 13C-acetic acid breath test performed continually using the BreathID system. Using Oridion Research Software (beta version), the time required for emptying of 50% of the labeled meal (T 1/2), the analog to the scintigraphy lag time for 10% emptying of the labeled meal (T lag), the gastric emptying coefficient (GEC), and the regression-estimated constants (beta and kappa) were calculated. The parameters measured under the two conditions were compared using the Wilcoxon's signed-rank test. No significant differences in the calculated parameters, namely, the T 1/2, T lag, GEC, beta or kappa, were observed between the two test conditions, namely, administration of a test meal+itopride and administration of the test meal alone. The present study revealed that postprandial itopride intake had no significant influence on the rate of gastric emptying. Recently, several studies have shown that itopride may be effective in the treatment of patients with functional dyspepsia. Our results suggest that the efficacy of itopride in patients with functional dyspepsia may be based on its effect of improving functions other than the rate of gastric emptying, such as the activities at neuronal sites, brain-gut correlation, visceral hypersensitivity, gastric accommodation and distension-induced adaptation.
Nierat, Marie-Cécile; Demiri, Suela; Dupuis-Lozeron, Elise; Allali, Gilles; Morélot-Panzini, Capucine; Similowski, Thomas; Adler, Dan
2016-01-01
Human breathing stems from automatic brainstem neural processes. It can also be operated by cortico-subcortical networks, especially when breathing becomes uncomfortable because of external or internal inspiratory loads. How the "irruption of breathing into consciousness" interacts with cognition remains unclear, but a case report in a patient with defective automatic breathing (Ondine's curse syndrome) has shown that there was a cognitive cost of breathing when the respiratory cortical networks were engaged. In a pilot study of putative breathing-cognition interactions, the present study relied on a randomized design to test the hypothesis that experimentally loaded breathing in 28 young healthy subjects would have a negative impact on cognition as tested by "timed up-and-go" test (TUG) and its imagery version (iTUG). Progressive inspiratory threshold loading resulted in slower TUG and iTUG performance. Participants consistently imagined themselves faster than they actually were. However, progressive inspiratory loading slowed iTUG more than TUG, a finding that is unexpected with regard to the known effects of dual tasking on TUG and iTUG (slower TUG but stable iTUG). Insofar as the cortical networks engaged in response to inspiratory loading are also activated during complex locomotor tasks requiring cognitive inputs, we infer that competition for cortical resources may account for the breathing-cognition interference that is evidenced here.
Effect of influenza vaccination on oxidative stress products in breath.
Phillips, Michael; Cataneo, Renee N; Chaturvedi, Anirudh; Danaher, Patrick J; Devadiga, Anantrai; Legendre, David A; Nail, Kim L; Schmitt, Peter; Wai, James
2010-06-01
Viral infections cause increased oxidative stress, so a breath test for oxidative stress biomarkers (alkanes and alkane derivatives) might provide a new tool for early diagnosis. We studied 33 normal healthy human subjects receiving scheduled treatment with live attenuated influenza vaccine (LAIV). Each subject was his or her own control, since they were studied on day 0 prior to vaccination, and then on days 2, 7 and 14 following vaccination. Breath volatile organic compounds (VOCs) were collected with a breath collection apparatus, then analyzed by automated thermal desorption with gas chromatography and mass spectroscopy. A Monte Carlo simulation technique identified non-random VOC biomarkers of infection based on their C-statistic values (area under curve of receiver operating characteristic). Treatment with LAIV was followed by non-random changes in the abundance of breath VOCs. 2, 8-Dimethyl-undecane and other alkane derivatives were observed on all days. Conservative multivariate models identified vaccinated subjects on day 2 (C-statistic = 0.82, sensitivity = 63.6% and specificity = 88.5%); day 7 (C-statistic = 0.94, sensitivity = 88.5% and specificity = 92.3%); and day 14 (C-statistic = 0.95, sensitivity = 92.3% and specificity = 92.3%). The altered breath VOCs were not detected in live attenuated influenza vaccine, excluding artifactual contamination. LAIV vaccination in healthy humans elicited a prompt and sustained increase in breath biomarkers of oxidative stress. A breath test for these VOCs could potentially identify humans who are acutely infected with influenza, but who have not yet developed clinical symptoms or signs of disease.
Hegar, Badriul; Hutapea, Esther I; Advani, Najid; Vandenplas, Yvan
2013-01-01
To evaluate the incidence of small bowel bacterial overgrowth (SBBO) in children treated with omeprazole, and to test whether probiotics influence the incidence. A double-blinded, placebo-controlled trial was performed in 70 children treated orally during four weeks with 20mg omeprazole per day. Lactobacillus rhamnosus R0011 (1.9×10(9) cfu) and Lactobacillus acidophilus R0052 (0.1×10(9) cfu) were simultaneously given daily to 36 subjects (probiotic group), while 34 subjects received placebo (placebo group). The diagnosis of SBBO was based on the development of suggestive symptoms, in combination with a positive glucose breath test. After one month of proton pump inhibitor (PPI) treatment, 30% (21/70) had a positive breath test suggesting SBBO; of these 62% were symptomatic. Five children developed SBBO-like symptoms, but had a negative breath test; and 44 (63%) were symptom free and had a negative breath test. There was no difference in the incidence of positive breath tests in the probiotic versus the placebo group (33% vs 26.5%; p=0.13). Since symptoms suggesting SBBO developed in 26% of PPI-treated children, and since the glucose breath test was abnormal in 72% of these, this side-effect should be more frequently considered. The probiotic tested did not decrease the risk to develop SBBO. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Controlled breathing protocols probe human autonomic cardiovascular rhythms
NASA Technical Reports Server (NTRS)
Cooke, W. H.; Cox, J. F.; Diedrich, A. M.; Taylor, J. A.; Beightol, L. A.; Ames, J. E. 4th; Hoag, J. B.; Seidel, H.; Eckberg, D. L.
1998-01-01
The purpose of this study was to determine how breathing protocols requiring varying degrees of control affect cardiovascular dynamics. We measured inspiratory volume, end-tidal CO2, R-R interval, and arterial pressure spectral power in 10 volunteers who followed the following 5 breathing protocols: 1) uncontrolled breathing for 5 min; 2) stepwise frequency breathing (at 0.3, 0.25, 0.2, 0.15, 0.1, and 0.05 Hz for 2 min each); 3) stepwise frequency breathing as above, but with prescribed tidal volumes; 4) random-frequency breathing (approximately 0.5-0.05 Hz) for 6 min; and 5) fixed-frequency breathing (0.25 Hz) for 5 min. During stepwise breathing, R-R interval and arterial pressure spectral power increased as breathing frequency decreased. Control of inspired volume reduced R-R interval spectral power during 0.1 Hz breathing (P < 0.05). Stepwise and random-breathing protocols yielded comparable coherence and transfer functions between respiration and R-R intervals and systolic pressure and R-R intervals. Random- and fixed-frequency breathing reduced end-tidal CO2 modestly (P < 0.05). Our data suggest that stringent tidal volume control attenuates low-frequency R-R interval oscillations and that fixed- and random-rate breathing may decrease CO2 chemoreceptor stimulation. We conclude that autonomic rhythms measured during different breathing protocols have much in common but that a stepwise protocol without stringent control of inspired volume may allow for the most efficient assessment of short-term respiratory-mediated autonomic oscillations.
The rise in carboxyhemoglobin from repeated pulmonary diffusing capacity tests.
Zavorsky, Gerald S
2013-03-01
The purpose of this study determined the rise in carboxyhemoglobin percentage (COHb) from repeated pulmonary diffusing capacity tests using 5 or 10s single breath-hold maneuvers. Five male and four female non-smokers [baseline COHb=1.2 (SD 0.5%)] performed repeated pulmonary diffusing capacity testing on two separate days. The days were randomized to either repeated 10s (0.28% CO), or 5s (0.28% CO, 55ppm NO) breath-hold maneuvers. Twenty-two 5s breath-hold maneuvers, each separated by 4min rest, raised COHb to 11.1 (1.4)% and minimally raised the methemoglobin percentage (METHb) by 0.3 (0.2)% to a value of 0.8 (0.2)%. After the 22nd test, pulmonary diffusing capacity for carbon monoxide (DLCO) was reduced by about 4mL/min/mmHg, equating to a 0.44% increase in COHb per 5s breath-hold maneuver and a concomitant 0.35mL/min/mmHg decrease in DLCO. Pulmonary diffusing capacity for nitric oxide (DLNO) was not altered after 22 tests. On another day, the 10s single breath-hold maneuver increased COHb by 0.64% per test, and reduced DLCO by 0.44mL/min/mmHg per test. In conclusion, 5s breath-hold maneuvers do not appreciably raise METHb or DLNO, and DLCO is only significantly reduced when COHb is at least 6%. Copyright © 2013 Elsevier B.V. All rights reserved.
The Effect of Diaphragmatic Breathing on Attention, Negative Affect and Stress in Healthy Adults.
Ma, Xiao; Yue, Zi-Qi; Gong, Zhu-Qing; Zhang, Hong; Duan, Nai-Yue; Shi, Yu-Tong; Wei, Gao-Xia; Li, You-Fa
2017-01-01
A growing number of empirical studies have revealed that diaphragmatic breathing may trigger body relaxation responses and benefit both physical and mental health. However, the specific benefits of diaphragmatic breathing on mental health remain largely unknown. The present study aimed to investigate the effect of diaphragmatic breathing on cognition, affect, and cortisol responses to stress. Forty participants were randomly assigned to either a breathing intervention group (BIG) or a control group (CG). The BIG received intensive training for 20 sessions, implemented over 8 weeks, employing a real-time feedback device, and an average respiratory rate of 4 breaths/min, while the CG did not receive this treatment. All participants completed pre- and post-tests of sustained attention and affect. Additionally, pre-test and post-test salivary cortisol concentrations were determined in both groups. The findings suggested that the BIG showed a significant decrease in negative affect after intervention, compared to baseline. In the diaphragmatic breathing condition, there was a significant interaction effect of group by time on sustained attention, whereby the BIG showed significantly increased sustained attention after training, compared to baseline. There was a significant interaction effect of group and time in the diaphragmatic breathing condition on cortisol levels, whereby the BIG had a significantly lower cortisol level after training, while the CG showed no significant change in cortisol levels. In conclusion, diaphragmatic breathing could improve sustained attention, affect, and cortisol levels. This study provided evidence demonstrating the effect of diaphragmatic breathing, a mind-body practice, on mental function, from a health psychology approach, which has important implications for health promotion in healthy individuals.
Prevalence of alcohol-impaired driving and riding in northern Ghana.
Damsere-Derry, James; Palk, Gavan; King, Mark
2016-01-01
The objective of this study was to determine the roadside prevalence of alcohol-impaired driving among drivers and riders in northern Ghana. The study also verifies motorists' perceptions of their own alcohol use and knowledge of the legal blood alcohol concentration (BAC) limit in Ghana. With the assistance of police, systematic random sampling was used to collect data at roadblocks using a cross-sectional study design. Breathalyzers were used to screen whether motorists had detectable alcohol in their breath and follow-up breath tests were conducted to measure the actual breath alcohol levels among positive participants. In all, 9.7% of the 789 participants had detectable alcohol, among whom 6% exceeded the legal BAC limit of 0.08%. The prevalence of alcohol-impaired driving/riding was highest among cyclists (10% of all cyclists breath-tested) followed by truck drivers (9%) and motorcyclists (7% of all motorcyclists breath-tested). The occurrence of a positive BAC among cyclists was about 8 times higher (odds ratio [OR] = 7.73; P < .001) and it was 2 times higher among motorcyclists (OR = 2.30; P = .039) compared to private car drivers. The likelihood for detecting a positive BAC among male motorists/riders was higher than that among females (OR = 1.67; P = .354). The odds for detecting a positive BAC among weekend motorists/riders was significantly higher than on weekdays (OR = 2.62; P = .001). Alcohol-impaired driving/riding in Ghana is high by international standards. In order to attenuate the harmful effects of alcohol misuse such as alcohol-impaired driving/riding, there is the need to educate road users about how much alcohol they can consume and stay below the legal limit. The police should also initiate random breath testing to instill the deterrence of detection, certainty of apprehension and punishment, and severity and celerity of punishment among drink-driving motorists and riders.
Roubík, Karel; Sieger, Ladislav; Sykora, Karel
2015-01-01
Presence of an air pocket and its size play an important role in survival of victims buried in the avalanche snow. Even small air pockets facilitate breathing. We hypothesize that the size of the air pocket significantly affects the airflow resistance and work of breathing. The aims of the study are (1) to investigate the effect of the presence of an air pocket on gas exchange and work of breathing in subjects breathing into the simulated avalanche snow and (2) to test whether it is possible to breathe with no air pocket. The prospective interventional double-blinded study involved 12 male volunteers, from which 10 completed the whole protocol. Each volunteer underwent two phases of the experiment in a random order: phase "AP"--breathing into the snow with a one-liter air pocket, and phase "NP"--breathing into the snow with no air pocket. Physiological parameters, fractions of oxygen and carbon dioxide in the airways and work of breathing expressed as pressure-time product were recorded continuously. The main finding of the study is that it is possible to breath in the avalanche snow even with no air pocket (0 L volume), but breathing under this condition is associated with significantly increased work of breathing. The significant differences were initially observed for end-tidal values of the respiratory gases (EtO2 and EtCO2) and peripheral oxygen saturation (SpO2) between AP and NP phases, whereas significant differences in inspiratory fractions occurred much later (for FIO2) or never (for FICO2). The limiting factor in no air pocket conditions is excessive increase in work of breathing that induces increase in metabolism accompanied by higher oxygen consumption and carbon dioxide production. The presence of even a small air pocket reduces significantly the work of breathing.
Beccaria, Marco; Mellors, Theodore R; Petion, Jacky S; Rees, Christiaan A; Nasir, Mavra; Systrom, Hannah K; Sairistil, Jean W; Jean-Juste, Marc-Antoine; Rivera, Vanessa; Lavoile, Kerline; Severe, Patrice; Pape, Jean W; Wright, Peter F; Hill, Jane E
2018-02-01
Tuberculosis (TB) remains a global public health malady that claims almost 1.8 million lives annually. Diagnosis of TB represents perhaps one of the most challenging aspects of tuberculosis control. Gold standards for diagnosis of active TB (culture and nucleic acid amplification) are sputum-dependent, however, in up to a third of TB cases, an adequate biological sputum sample is not readily available. The analysis of exhaled breath, as an alternative to sputum-dependent tests, has the potential to provide a simple, fast, and non-invasive, and ready-available diagnostic service that could positively change TB detection. Human breath has been evaluated in the setting of active tuberculosis using thermal desorption-comprehensive two-dimensional gas chromatography-time of flight mass spectrometry methodology. From the entire spectrum of volatile metabolites in breath, three random forest machine learning models were applied leading to the generation of a panel of 46 breath features. The twenty-two common features within each random forest model used were selected as a set that could distinguish subjects with confirmed pulmonary M. tuberculosis infection and people with other pathologies than TB. Copyright © 2018 Elsevier B.V. All rights reserved.
Alcañiz, Manuela; Guillén, Montserrat; Santolino, Miguel; Sánchez-Moscona, Daniel; Llatje, Oscar; Ramon, Lluís
2014-04-01
Sobriety checkpoints are not usually randomly located by traffic authorities. As such, information provided by non-random alcohol tests cannot be used to infer the characteristics of the general driving population. In this paper a case study is presented in which the prevalence of alcohol-impaired driving is estimated for the general population of drivers. A stratified probabilistic sample was designed to represent vehicles circulating in non-urban areas of Catalonia (Spain), a region characterized by its complex transportation network and dense traffic around the metropolis of Barcelona. Random breath alcohol concentration tests were performed during spring 2012 on 7596 drivers. The estimated prevalence of alcohol-impaired drivers was 1.29%, which is roughly a third of the rate obtained in non-random tests. Higher rates were found on weekends (1.90% on Saturdays and 4.29% on Sundays) and especially at night. The rate is higher for men (1.45%) than for women (0.64%) and it shows an increasing pattern with age. In vehicles with two occupants, the proportion of alcohol-impaired drivers is estimated at 2.62%, but when the driver was alone the rate drops to 0.84%, which might reflect the socialization of drinking habits. The results are compared with outcomes in previous surveys, showing a decreasing trend in the prevalence of alcohol-impaired drivers over time. Copyright © 2014 Elsevier Ltd. All rights reserved.
Prediction of breast cancer risk with volatile biomarkers in breath.
Phillips, Michael; Cataneo, Renee N; Cruz-Ramos, Jose Alfonso; Huston, Jan; Ornelas, Omar; Pappas, Nadine; Pathak, Sonali
2018-03-23
Human breath contains volatile organic compounds (VOCs) that are biomarkers of breast cancer. We investigated the positive and negative predictive values (PPV and NPV) of breath VOC biomarkers as indicators of breast cancer risk. We employed ultra-clean breath collection balloons to collect breath samples from 54 women with biopsy-proven breast cancer and 124 cancer-free controls. Breath VOCs were analyzed with gas chromatography (GC) combined with either mass spectrometry (GC MS) or surface acoustic wave detection (GC SAW). Chromatograms were randomly assigned to a training set or a validation set. Monte Carlo analysis identified significant breath VOC biomarkers of breast cancer in the training set, and these biomarkers were incorporated into a multivariate algorithm to predict disease in the validation set. In the unsplit dataset, the predictive algorithms generated discriminant function (DF) values that varied with sensitivity, specificity, PPV and NPV. Using GC MS, test accuracy = 90% (area under curve of receiver operating characteristic in unsplit dataset) and cross-validated accuracy = 77%. Using GC SAW, test accuracy = 86% and cross-validated accuracy = 74%. With both assays, a low DF value was associated with a low risk of breast cancer (NPV > 99.9%). A high DF value was associated with a high risk of breast cancer and PPV rising to 100%. Analysis of breath VOC samples collected with ultra-clean balloons detected biomarkers that accurately predicted risk of breast cancer.
Kamath, Ashwin; Urval, Rathnakar P; Shenoy, Ashok K
2017-01-01
A randomized controlled pilot study was carried out to determine the effect of a 15-minute practice of ANB exercise on experimentally induced anxiety using the simulated public speaking model in yoga-naïve healthy young adults. Thirty consenting medical students were equally divided into test and control groups. The test group performed alternate nostril breathing exercise for 15 minutes, while the control group sat in a quiet room before participating in the simulated public speaking test (SPST). Visual Analog Mood Scale and Self-Statements during Public Speaking scale were used to measure the mood state at different phases of the SPST. The psychometric scores of both groups were comparable at baseline. Repeated-measures ANOVA showed a significant effect of phase ( p < 0.05), but group and gender did not have statistically significant influence on the mean anxiety scores. However, the test group showed a trend towards lower mean scores for the anxiety factor when compared with the control group. Considering the limitations of this pilot study and the trend seen towards lower anxiety in the test group, alternate nostril breathing may have potential anxiolytic effect in acute stressful situations. A study with larger sample size is therefore warranted. This trial is registered with CTRI/2014/03/004460.
Urval, Rathnakar P.; Shenoy, Ashok K.
2017-01-01
A randomized controlled pilot study was carried out to determine the effect of a 15-minute practice of ANB exercise on experimentally induced anxiety using the simulated public speaking model in yoga-naïve healthy young adults. Thirty consenting medical students were equally divided into test and control groups. The test group performed alternate nostril breathing exercise for 15 minutes, while the control group sat in a quiet room before participating in the simulated public speaking test (SPST). Visual Analog Mood Scale and Self-Statements during Public Speaking scale were used to measure the mood state at different phases of the SPST. The psychometric scores of both groups were comparable at baseline. Repeated-measures ANOVA showed a significant effect of phase (p < 0.05), but group and gender did not have statistically significant influence on the mean anxiety scores. However, the test group showed a trend towards lower mean scores for the anxiety factor when compared with the control group. Considering the limitations of this pilot study and the trend seen towards lower anxiety in the test group, alternate nostril breathing may have potential anxiolytic effect in acute stressful situations. A study with larger sample size is therefore warranted. This trial is registered with CTRI/2014/03/004460. PMID:29159176
He, Xinjian; Grinshpun, Sergey A; Reponen, Tiina; McKay, Roy; Bergman, Michael S; Zhuang, Ziqing
2014-03-01
The objective of this study was to investigate the effects of breathing frequency and flow rate on the total inward leakage (TIL) of an elastomeric half-mask donned on an advanced manikin headform and challenged with combustion aerosols. An elastomeric half-mask respirator equipped with P100 filters was donned on an advanced manikin headform covered with life-like soft skin and challenged with aerosols originated by burning three materials: wood, paper, and plastic (polyethylene). TIL was determined as the ratio of aerosol concentrations inside (C in) and outside (C out) of the respirator (C in/C out) measured with a nanoparticle spectrometer operating in the particle size range of 20-200nm. The testing was performed under three cyclic breathing flows [mean inspiratory flow (MIF) of 30, 55, and 85 l/min] and five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). A completely randomized factorial study design was chosen with four replicates for each combination of breathing flow rate and frequency. Particle size, MIF, and combustion material had significant (P < 0.001) effects on TIL regardless of breathing frequency. Increasing breathing flow decreased TIL. Testing with plastic aerosol produced higher mean TIL values than wood and paper aerosols. The effect of the breathing frequency was complex. When analyzed using all combustion aerosols and MIFs (pooled data), breathing frequency did not significantly (P = 0.08) affect TIL. However, once the data were stratified according to combustion aerosol and MIF, the effect of breathing frequency became significant (P < 0.05) for all MIFs challenged with wood and paper combustion aerosols, and for MIF = 30 l/min only when challenged with plastic combustion aerosol. The effect of breathing frequency on TIL is less significant than the effects of combustion aerosol and breathing flow rate for the tested elastomeric half-mask respirator. The greatest TIL occurred when challenged with plastic aerosol at 30 l/min and at a breathing frequency of 30 breaths/min.
Detection of flow limitation in obstructive sleep apnea with an artificial neural network.
Norman, Robert G; Rapoport, David M; Ayappa, Indu
2007-09-01
During sleep, the development of a plateau on the inspiratory airflow/time contour provides a non-invasive indicator of airway collapsibility. Humans recognize this abnormal contour easily, and this study replicates this with an artificial neural network (ANN) using a normalized shape. Five 10 min segments were selected from each of 18 sleep records (respiratory airflow measured with a nasal cannula) with varying degrees of sleep disordered breathing. Each breath was visually scored for shape, and breaths split randomly into a training and test set. Equally spaced, peak amplitude normalized flow values (representing breath shape) formed the only input to a back propagation ANN. Following training, breath-by-breath agreement of the ANN with the manual classification was tabulated for the training and test sets separately. Agreement of the ANN was 89% in the training set and 70.6% in the test set. When the categories of 'probably normal' and 'normal', and 'probably flow limited' and 'flow limited' were combined, the agreement increased to 92.7% and 89.4% respectively, similar to the intra- and inter-rater agreements obtained by a visual classification of these breaths. On a naive dataset, the agreement of the ANN to visual classification was 57.7% overall and 82.4% when the categories were collapsed. A neural network based only on the shape of inspiratory airflow succeeded in classifying breaths as to the presence/absence of flow limitation. This approach could be used to provide a standardized, reproducible and automated means of detecting elevated upper airway resistance.
Modak, Anil; Durso, Raymon; Josephs, Ephraim; Rosen, David
2012-01-01
Peripheral carbidopa (CD) levels directly impact on central dopamine (DA) production in Parkinson disease (PD) through extracerebral inhibition of dopa decarboxylase (AADC) resulting in an increase in levodopa (LD) bioavailability. Recent data suggests that higher CD doses than those presently used in PD treatment may result in improved clinical response. Optimizing CD doses in individual patients may, therefore, result in ideal individualized treatment. A single center, randomized, double-blind study was carried out recruiting 5 Parkinson’s disease (PD) patients already on LD/CD and 1 treatment näve PD patient using stable isotope labeled LD-1-¹³C as a substrate for a noninvasive breath test to evaluate individual AADC enzyme activity. Each patient was studied five times, receiving 200 mg LD-¹³C at each visit along with one of five randomized CD doses (0, 25, 50, 100 and 200 mg). The metabolite ¹³CO₂ in breath was measured for evaluating AADC enzyme activity and plasma metabolite levels for LD-¹³C and homovanillic acid (HVA) were measured for 4 hours. HVA in plasma and ¹³CO₂ in breath are metabolic products of LD. We found a significant positive correlation of ¹³CO₂ DOB AUC0-240 with serum HVA AUC0-240 following the oral dose of LD-1-¹³C for all 5 doses of CD (r² = 0.9378). With increasing inhibition of AADC enzyme activity with CD, we observed an increase in the plasma concentration of LD.We found an inverse correlation of the 13CO2 DOB AUC with serum LD-¹³C AUC. Our studies indicate the optimal dose of CD for maximal suppression of AADC enzyme activity can be determined for each individual from ¹³CO₂ generation in breath. The LD-breath test can be a useful noninvasive diagnostic tool for evaluation of AADC enzyme activity using the biomarker ¹³CO₂ in breath, a first step in personalizing CD doses for PD patients.
Random breath testing in Australia: getting it to work according to specifications.
Homel, R
1993-01-01
After reading the deterrence literature, particularly the work of H. Laurence Ross, I concluded in the late 1970's that many road accidents could be prevented through the wholehearted implementation of random breath testing (RBT). RBT is a system of drink-drive law enforcement which aims to increase the perceived likelihood of apprehension through the use of mass breath testing techniques at roadblocks which are highly visible, are unpredictable in their locations and give the impression of ubiquity. As the result of public pressure, RBT was introduced in NSW in December 1982, with spectacular results. The law was intensively enforced and extensively advertised, partly due to the advocacy of researchers such as myself, but also because ther was an acute political need for instant results. Since RBT is a difficult enforcement technique for police to sustain in effective form, researchers must strive to improve their understanding of what works, and remain in close contact with police, policy makers and politicians. Although this process is costly in terms of time and, possibly, academic 'pay-off', it is essential if the fragile understanding of deterrence principles amongst these groups is not to lead to superficially attractive, but probably ineffective techniques such as low visibility mobile RBT.
A mind you can count on: validating breath counting as a behavioral measure of mindfulness.
Levinson, Daniel B; Stoll, Eli L; Kindy, Sonam D; Merry, Hillary L; Davidson, Richard J
2014-01-01
Mindfulness practice of present moment awareness promises many benefits, but has eluded rigorous behavioral measurement. To date, research has relied on self-reported mindfulness or heterogeneous mindfulness trainings to infer skillful mindfulness practice and its effects. In four independent studies with over 400 total participants, we present the first construct validation of a behavioral measure of mindfulness, breath counting. We found it was reliable, correlated with self-reported mindfulness, differentiated long-term meditators from age-matched controls, and was distinct from sustained attention and working memory measures. In addition, we employed breath counting to test the nomological network of mindfulness. As theorized, we found skill in breath counting associated with more meta-awareness, less mind wandering, better mood, and greater non-attachment (i.e., less attentional capture by distractors formerly paired with reward). We also found in a randomized online training study that 4 weeks of breath counting training improved mindfulness and decreased mind wandering relative to working memory training and no training controls. Together, these findings provide the first evidence for breath counting as a behavioral measure of mindfulness.
Lucy, Malcolm J; Gamble, Jonathan J; Daku, Brian L; Bryce, Rhonda D; Rana, Masud
2014-12-01
Positive-pressure ventilation during transport of intubated patients is generally delivered via a hand-pressurized device. Of these devices, self-inflating resuscitators (SIR) and flow-inflating resuscitators (FIR) constitute the two major types used. Selection of a particular device for transport, however, remains largely an institutional practice. To evaluate the hypothesis that transport ventilation goals of intubated pediatric patients are better achieved using an FIR compared to an SIR. This randomized crossover simulation study compared the performance of SIR and FIR among anesthesia providers in a pediatric transport scenario. Subjects hand-ventilated a test lung while simultaneously maneuvering a stretcher bed to simulate patient transport. Hand ventilation was carried out using a Jackson-Rees circuit (FIR) and a Laerdal pediatric silicone resuscitator (SIR). The primary outcome was the proportion of total breaths delivered within the predefined target PIP/PEEP range (30+/- 3, 10+/- 3 cm H2O). Secondary outcomes included proportion of total breaths delivered with operationally defined unacceptable breath variables (PIP > 35 cm H2O or PEEP < 5 cm H2O). Overall, participants were four times more likely to deliver target breaths and one-third less likely to deliver unacceptable breaths using the FIR compared to the SIR. When comparing device performance, a 44% increase in the proportions of target breaths and a 40.4% decrease in unacceptable breaths using the FIR were observed (P < 0.0001 for both). Hand ventilation during patient transport is superior using the FIR compared to the SIR to achieve target ventilatory goals and avoid unacceptable ventilatory cycles. © 2014 John Wiley & Sons Ltd.
Evans, B W; Potteiger, J A
1995-06-01
This study compared ventilatory and metabolic responses during exercise using three breathing assemblies: mouthpiece/noseclip (BV); mouth/face mask (MM); and facemask (FM). Ten male runners completed three maximal treadmill tests with breathing assembly randomly assigned. Metabolic and ventilatory data were recorded every 15s, and heart rate (HR) and rating of perceived exertion (RPE) each min. No significant differences were found for treadmill run time, HRmax, respiratory exchange ratio (RER), and RPE, indicating similar efforts on all trials. No significant differences were found at maximal exercise for VO2 minute ventilation (VE), tidal volume (VT), and breathing frequency (f). At ventilatory threshold (TVENT), VO2, VE, and f were not significantly different. However, peak flow (PF) was significantly higher for BV than FM, and VT was significantly higher for BV than MM and FM. Results indicate alterations in ventilatory mechanics occur at TVENT, but type of breathing assembly does not significantly affect maximal values.
Effect of DA-9701 on gastric emptying in a mouse model: assessment by ¹³C-octanoic acid breath test.
Lim, Chul-Hyun; Choi, Myung-Gyu; Park, Hyeyeon; Baeg, Myong Ki; Park, Jae Myung
2013-07-21
To evaluate the effects of DA-9701 on the gastric emptying of a solid meal using the ¹³C-octanoic acid breath test in a mouse model. Male C57BL/6 mice aged > 8 wk and with body weights of 20-25 g were used in this study. The solid test meal consisted of 200 mg of egg yolk labeled with 1.5 L/g ¹³C-octanoic acid. The mice were placed in a 130 mL chamber flushed with air at a flow speed of 200 mL/min. Breath samples were collected for 6 h. The half-emptying time and lag phase were calculated using a modified power exponential model. To assess the reproducibility of the ¹³C-octanoic acid breath test, the breath test was performed two times at intervals of one week in ten mice without drug treatment. To assess the gastrokinetic effects of DA-9701, the breath test was performed three times in another twelve mice, with a randomized crossover sequence of three drug treatments: DA-9701 3 mg/kg, erythromycin 6 mg/kg, or saline. Each breath test was performed at an interval of one week. Repeatedly measured half gastric emptying time of ten mice without drug treatment showed 0.856 of the intraclass correlation coefficient for the half gastric emptying time (P = 0.004). The mean cumulative excretion curve for the ¹³C-octanoic acid breath test showed accelerated gastric emptying after DA-9701 treatment compared with the saline control (P = 0.028). The median half gastric emptying time after the DA-9701 treatment was significantly shorter than after the saline treatment [122.4 min (109.0-137.9 min) vs 134.5 min (128.4-167.0 min), respectively; P = 0.028] and similar to that after the erythromycin treatment [123.3 min (112.9-138.2 min)]. The lag phase, which was defined as the period taken to empty 15% of a meal, was significantly shorter after the DA-9701 treatment than after the saline treatment [48.1 min (44.6-57.1 min) vs 52.6 min (49.45-57.4 min), respectively; P = 0.049]. The novel prokinetic agent DA-9701 accelerated gastric emptying, assessed with repeated measurements in the same mouse using the ¹³C-octanoic acid breath test. Our findings suggest that DA-9701 has therapeutic potential for the treatment of functional dyspepsia.
Blinded Validation of Breath Biomarkers of Lung Cancer, a Potential Ancillary to Chest CT Screening
Phillips, Michael; Bauer, Thomas L.; Cataneo, Renee N.; Lebauer, Cassie; Mundada, Mayur; Pass, Harvey I.; Ramakrishna, Naren; Rom, William N.; Vallières, Eric
2015-01-01
Background Breath volatile organic compounds (VOCs) have been reported as biomarkers of lung cancer, but it is not known if biomarkers identified in one group can identify disease in a separate independent cohort. Also, it is not known if combining breath biomarkers with chest CT has the potential to improve the sensitivity and specificity of lung cancer screening. Methods Model-building phase (unblinded): Breath VOCs were analyzed with gas chromatography mass spectrometry in 82 asymptomatic smokers having screening chest CT, 84 symptomatic high-risk subjects with a tissue diagnosis, 100 without a tissue diagnosis, and 35 healthy subjects. Multiple Monte Carlo simulations identified breath VOC mass ions with greater than random diagnostic accuracy for lung cancer, and these were combined in a multivariate predictive algorithm. Model-testing phase (blinded validation): We analyzed breath VOCs in an independent cohort of similar subjects (n = 70, 51, 75 and 19 respectively). The algorithm predicted discriminant function (DF) values in blinded replicate breath VOC samples analyzed independently at two laboratories (A and B). Outcome modeling: We modeled the expected effects of combining breath biomarkers with chest CT on the sensitivity and specificity of lung cancer screening. Results Unblinded model-building phase. The algorithm identified lung cancer with sensitivity 74.0%, specificity 70.7% and C-statistic 0.78. Blinded model-testing phase: The algorithm identified lung cancer at Laboratory A with sensitivity 68.0%, specificity 68.4%, C-statistic 0.71; and at Laboratory B with sensitivity 70.1%, specificity 68.0%, C-statistic 0.70, with linear correlation between replicates (r = 0.88). In a projected outcome model, breath biomarkers increased the sensitivity, specificity, and positive and negative predictive values of chest CT for lung cancer when the tests were combined in series or parallel. Conclusions Breath VOC mass ion biomarkers identified lung cancer in a separate independent cohort, in a blinded replicated study. Combining breath biomarkers with chest CT could potentially improve the sensitivity and specificity of lung cancer screening. Trial Registration ClinicalTrials.gov NCT00639067 PMID:26698306
Aboumatar, H; Naqibuddin, M; Chung, S; Adebowale, H; Bone, L; Brown, T; Cooper, L A; Gurses, A P; Knowlton, A; Kurtz, D; Piet, L; Putcha, N; Rand, C; Roter, D; Shattuck, E; Sylvester, C; Urteaga-Fuentes, A; Wise, R; Wolff, J L; Yang, T; Hibbard, J; Howell, E; Myers, M; Shea, K; Sullivan, J; Syron, L; Wang, Nae-Yuh; Pronovost, P
2017-11-01
Chronic Obstructive Pulmonary Disease (COPD) is a leading cause of hospitalizations. Interventional studies focusing on the hospital-to-home transition for COPD patients are few. In the BREATHE (Better Respiratory Education and Treatment Help Empower) study, we developed and tested a patient and family-centered transitional care program that helps prepare hospitalized COPD patients and their family caregivers to manage COPD at home. In the study's initial phase, we co-developed the BREATHE transitional care program with COPD patients, family-caregivers, and stakeholders. The program offers tailored services to address individual patients' needs and priorities at the hospital and for 3months post discharge. We tested the program in a single-blinded RCT with 240 COPD patients who were randomized to receive the program or 'usual care'. Program participants were offered the opportunity to invite a family caregiver, if available, to enroll with them into the study. The primary outcomes were the combined number of COPD-related hospitalizations and Emergency Department (ED) visits per participant at 6months post discharge, and the change in health-related quality of life over the 6months study period. Other measures include 'all cause' hospitalizations and ED visits; patient activation; self-efficacy; and, self-care behaviors. Unlike 1month transitional care programs that focus on patients' post-acute care needs, the BREATHE program helps hospitalized COPD patients manage the post discharge period as well as prepare them for long term self-management of COPD. If proven effective, this program may offer a timely solution for hospitals in their attempts to reduce COPD rehospitalizations. Copyright © 2017 Elsevier Inc. All rights reserved.
Young, A; Jonski, G
2011-12-01
This randomized, double-blind, 12 h clinical study tested the effect of a single brushing with two Zn-containing toothpastes on volatile sulfur compound (VSC) levels in morning breath. The following toothpastes were each tested by all 28 participants: A-Zn toothpaste, B--experimental toothpaste (Zn citrate + PVM/MA copolymer) and C--control toothpaste without Zn. The evening prior to test days participants brushed their teeth for 2 min with 1 g toothpaste. 12 h later and prior to eating or performing oral hygiene, morning breath levels of VSC (H(2)S, CH(3)SH) were analysed by gas chromatography. Subjects then rinsed for 30 s with 5 ml cysteine and breath samples were analysed for H(2)S (H(2)S(cys)). Median VSC (area under the curve) values were compared for A, B and C and the effects of A and B on VSC were compared with C. Toothpaste B was more effective than both toothpastes A and C in reducing H(2)S, CH(3)SH and H(2)S(cys) (p < 0.05). Compared with toothpaste C, toothpastes A and B reduced H(2)S by 35% and 68%, respectively (p = 0.003), and CH(3)SH by 12% and 47%, respectively (p = 0.002). Toothpaste B reduced H(2)S(cys) by 48% compared with toothpaste C (p = 0.001). It is suggested that the superior effect of the experimental toothpaste was most likely due to a higher Zn concentration combined with longer retention of Zn due to the PVM/MA copolymer.
49 CFR 382.401 - Retention of records.
Code of Federal Regulations, 2010 CFR
2010-10-01
... substances collection process (except calibration of evidential breath testing devices). (3) One year... record is required to be prepared, it must be maintained. (1) Records related to the collection process: (i) Collection logbooks, if used; (ii) Documents relating to the random selection process; (iii...
Westerdahl, Elisabeth; Wittrin, Anna; Kånåhols, Margareta; Gunnarsson, Martin; Nilsagård, Ylva
2016-11-01
Breathing exercises with positive expiratory pressure are often recommended to patients with advanced neurological deficits, but the potential benefit in multiple sclerosis (MS) patients with mild and moderate symptoms has not yet been investigated in randomized controlled trials. To study the effects of 2 months of home-based breathing exercises for patients with mild to moderate MS on respiratory muscle strength, lung function, and subjective breathing and health status outcomes. Forty-eight patients with MS according to the revised McDonald criteria were enrolled in a randomized controlled trial. Patients performing breathing exercises (n = 23) were compared with a control group (n = 25) performing no breathing exercises. The breathing exercises were performed with a positive expiratory pressure device (10-15 cmH 2 O) and consisted of 30 slow deep breaths performed twice a day for 2 months. Respiratory muscle strength (maximal inspiratory and expiratory pressure at the mouth), spirometry, oxygenation, thoracic excursion, subjective perceptions of breathing and self-reported health status were evaluated before and after the intervention period. Following the intervention, there was a significant difference between the breathing group and the control group regarding the relative change in lung function, favoring the breathing group (vital capacity: P < 0.043; forced vital capacity: P < 0.025). There were no other significant differences between the groups. Breathing exercises may be beneficial in patients with mild to moderate stages of MS. However, the clinical significance needs to be clarified, and it remains to be seen whether a sustainable effect in delaying the development of respiratory dysfunction in MS can be obtained. © 2015 The Authors. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.
Pradhan, Balaram; Mohanty, Soubhagyalaxmi; Hankey, Alex
2018-01-01
Attentional processes tend to be less well developed in the visually impaired, who require special training to develop them fully. Yogic breathing which alters the patterns of respiration has been shown to enhance attention skills. Letter cancellation tests are well-established tools to measure attention and attention span. Here, a modified Braille version of the six-letter cancellation test (SLCT) was used for students with visual impairment (VI). This study aimed to assess the immediate effects of Bhramari Pranayama (BhPr) and breath awareness (BA) on students with VI. This study was a self-as-control study held on 2 consecutive days, on 19 participants (8 males, 11 females), with a mean age of 15.89 ± 1.59 years, randomized into two groups. On the 1 st day, Group 1 performed 10 min breath awareness and Group 2 performed Bhramari ; on the 2 nd day, practices were reversed. Assessments used a SLCT specially adapted for the visually impaired before and after each session. The Braille letter cancellation test was successfully taken by 19 students. Scores significantly improved after both techniques for each student following practices on both days ( P < 0.001). BhPr may have more effect on attention performance than BA as wrong scores significantly increased following BA ( P < 0.05), but the increase in the score after Bhramari was not significant. Despite the small sample size improvement in attentional processes by both yoga breathing techniques was robust. Attentional skills were definitely enhanced. Long-term practice should be studied.
Pradhan, Balaram; Mohanty, Soubhagyalaxmi; Hankey, Alex
2018-01-01
Context: Attentional processes tend to be less well developed in the visually impaired, who require special training to develop them fully. Yogic breathing which alters the patterns of respiration has been shown to enhance attention skills. Letter cancellation tests are well-established tools to measure attention and attention span. Here, a modified Braille version of the six-letter cancellation test (SLCT) was used for students with visual impairment (VI). Aim: This study aimed to assess the immediate effects of Bhramari Pranayama (BhPr) and breath awareness (BA) on students with VI. Methods: This study was a self-as-control study held on 2 consecutive days, on 19 participants (8 males, 11 females), with a mean age of 15.89 ± 1.59 years, randomized into two groups. On the 1st day, Group 1 performed 10 min breath awareness and Group 2 performed Bhramari; on the 2nd day, practices were reversed. Assessments used a SLCT specially adapted for the visually impaired before and after each session. Results: The Braille letter cancellation test was successfully taken by 19 students. Scores significantly improved after both techniques for each student following practices on both days (P < 0.001). BhPr may have more effect on attention performance than BA as wrong scores significantly increased following BA (P < 0.05), but the increase in the score after Bhramari was not significant. Conclusions: Despite the small sample size improvement in attentional processes by both yoga breathing techniques was robust. Attentional skills were definitely enhanced. Long-term practice should be studied. PMID:29755219
2004-09-01
Test participants cleared heavy, wet snow with either a shovel or an electric snow thrower in random order, with 10- to 15-minute rest periods between...automated snow thrower . Using the average subject population weight of 85.7 kg, estimated Po2 in L-min-l would be about 1.71 L-min-’ for shoveling and 0.72
THE EFFECTS OF FIXED VERSUS ESCALATING REINFORCEMENT SCHEDULES ON SMOKING ABSTINENCE
Romanowich, Paul; Lamb, R. J.
2015-01-01
Studies indicate that when abstinence is initiated, escalating reinforcement schedules maintain continuous abstinence longer than fixed reinforcement schedules. However, these studies were conducted for shorter durations than most clinical trials and also resulted in larger reinforcer value for escalating participants during the 1st week of the experiment. We tested whether escalating reinforcement schedules maintained abstinence longer than fixed reinforcement schedules in a 12-week clinical trial. Smokers (146) were randomized to an escalating reinforcement schedule, a fixed reinforcement schedule, or a control condition. Escalating reinforcement participants received $5.00 for their first breath carbon monoxide (CO) sample <3 ppm, with a $0.50 increase for each consecutive sample. Fixed reinforcement participants received $19.75 for each breath CO sample <3 ppm. Control participants received payments only for delivering a breath CO sample. Similar proportions of escalating and fixed reinforcement participants met the breath CO criterion at least once. Escalating reinforcement participants maintained criterion breath CO levels longer than fixed reinforcement and control participants. Similar to previous short-term studies, escalating reinforcement schedules maintained longer durations of abstinence than fixed reinforcement schedules during a clinical trial. PMID:25640764
Cheng, Kok Suen; Han, Ray P S; Lee, Poh Foong
2018-02-01
The study aims to study the effects of short duration deep breathing on the EEG power with topography based on parallel group randomized controlled trial design which was lacking in prior reports. 50 participants were split into 4 groups: control (CONT), deep breathing (DB) for 5 (DB5), 7 (DB7), and 9 (DB9) minutes. EEG recordings were obtained during baseline, deep breathing session, after deep breathing, and a follow-up session after 7 days of consecutive practice. Frontal theta power of DB5 and DB9 was significantly larger than that of CONT after the deep breathing session (p = 0.027 and p = 0.006, respectively) and the profound finding showed that the theta topography obtained a central-focused distribution for DB7 and DB9. The result obtained was consistent with previous literature, albeit for certain deep breathing durations only, indicating a possible linkage between the deep breathing duration and the neurophysiology of the brain. Copyright © 2017 Elsevier B.V. All rights reserved.
Does respiratory muscle training increase physical performance?
Sperlich, Billy; Fricke, Hannes; de Marées, Markus; Linville, John W; Mester, Joachim
2009-09-01
Special force units and military personnel undergo demanding physical exercise and might benefit from high-intensity respiratory muscle training (RMT) by increasing their endurance performance. This study examined the effects of a 6-week high-intensity RMT on running performance and oxygen uptake (VO2max) in a group of German Special Force Squad members. 17 participants were randomly assigned to a training or control group. Baseline and post-testing included a ramp test, as well as an incremental test on a treadmill, performed to physical exhaustion. VO2, respiratory exchange ratio, and heart rate were measured breath by breath. Furthermore, maximum running speed (V(max)), 4 mmol x 1(-1) lactate threshold (V4) and perception of respiratory effort were determined. During pulmonary testing, sustained maximum inspiratory and expiratory pressure (PI(max) and PE(max)) were obtained. RMT was performed daily at approximately 90% PI(max) for 6 weeks with 2 x 30 breath cycles using an Ultrabreathe lung trainer. No statistical differences were detected between the groups for any parameter after RMT. High-intensity RMT did not show any benefits on VO2max and endurance performance and are unlikely to be of benefit to military or paramilitary training programs for an increase in endurance performance.
Clinical comparison of a new manual toothbrush on breath volatile sulfur compounds.
Williams, Malcolm I; Vazquez, Joe; Cummins, Diane
2004-10-01
The objective of this randomized, crossover study was to compare the effectiveness of a newly designed manual toothbrush (Colgate 360 degrees) to two commercially available manual toothbrushes (Oral-B Indicator and Oral-B CrossAction) and a battery-powered toothbrush (Crest SpinBrush PRO) for their ability to reduce overnight volatile sulfur compounds (VSC) associated with oral malodor. The study followed a four-period crossover design. Following a washout period, prospective subjects arrived at the testing facility without eating, drinking, or performing oral hygiene for baseline evaluation of breath VSC levels. For each phase of the study, subjects were given one of the test tooth-brushes and a tube of regular toothpaste to take home, and they were instructed to brush their teeth in their customary manner for 1 minute. When using the Colgate 360 degrees toothbrush, subjects were instructed to clean their tongue with the implement on the back of the brush head for 10 seconds. The following morning, subjects reported to the testing facility, again without performing oral hygiene, eating, or drinking, for the overnight evaluation. After a minimum 2-day washout period, subjects repeated the same regimen using the other toothbrushes. The levels of breath VSC were evaluated instrumentally using a gas chromatograph equipped with a flame photometric detector. Measurements were taken in duplicate and then averaged. The levels of VSC were expressed as parts per billion (ppb) in mouth air. Sixteen men and women completed the study. At baseline, the mean levels of VSC in mouth air for the 4 toothbrushes were 719.8 ppb+/-318.4 ppb, 592.8 ppb+/-264.6 ppb, 673.8 ppb+/-405.9 ppb, and 656.2 ppb+/-310.2 ppb for the Colgate 360 degrees, Oral-B Indicator, Crest SpinBrush PRO, and Oral-B CrossAction, respectively. Overnight, the mean breath VSC levels after using the four toothbrushes were lower than those observed at baseline. The respective mean levels of breath VSC were 266.5 ppb+/-269.9 ppb, 545.2 ppb+/-346.1 ppb, 567 ppb+/-335.7 ppb, and 554.6 ppb+/-398.4 ppb. Only the Colgate 360 degrees toothbrush provided a statistically significant reduction (P < .05) in breath VSC vs baseline. Additionally, the Colgate 360 degrees toothbrush was statistically significantly better (P < .05) than the three commercial toothbrushes in reducing breath VSC. Therefore, the results of this randomized, crossover clinical study indicate that a newly designed manual toothbrush with a tongue-cleaning implement on the back of the brush head was significantly more effective than three commercially available toothbrushes in reducing morning breath VSC associated with oral malodor.
2014-10-01
SCI. In this prospective randomized controlled trial, we will objectively measure sleep disordered breathing ( SDB ) in chronic SCI patients using...portable sleep studies, and systematically evaluate the association between SDB , cognitive performance, mood, pain, and CV measures. We will randomize...randomized shortly. 15. SUBJECT TERMS SDB , SCI, PAP, CV 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a
Outcome of breath tests in adult patients with suspected small intestinal bacterial overgrowth
Mattsson, Johanna; Minaya, Maria Teresa; Monegro, Milka; Lebwohl, Benjamin; Lewis, Suzanne K.; Green, Peter HR; Stenberg, Reidun
2017-01-01
Aim: The aim was to investigate breath test outcomes in patients with suspected SIBO and indicative symptoms of SIBO, diagnosed by breath testing. Background: Breath testing is used to detect small intestinal bacterial overgrowth (SIBO) by measuring hydrogen and methane produced by intestinal bacteria. Methods: This retrospective cross sectional study included 311 patients with gastrointestinal symptoms who underwent the breath test for evaluation of SIBO at Celiac Disease Center at Columbia University, New York, in 2014-2015. The patients were divided into two groups based on the physician’s choice: lactulose breath test group (72%) and glucose breath test group (28%). Among them, 38% had a history of celiac disease or non-celiac gluten sensitivity. Results: In total, 46% had a positive breath test: 18% were positive for methane, 24 % positive for hydrogen and 4% positive for both gases (p=0.014). Also, 50% had a positive lactulose breath result and 37% had a positive glucose breath result (p=0.036). The most common symptom for performing the breath test was bloating and the only clinical symptom that significantly showed a positive glucose breath test was increased gas (p=0.028). Conclusion: Lactulose breath test was more often positive than glucose breath test. Positivity for hydrogen was more common than methane. Bloating was the most frequently perceived symptom of the patients undergoing the breath test but the only statistically significant clinical symptom for a positive glucose breath test was increased gas. Furthermore, the results showed that there was no significant association between positive breath test result and gender, age, non-celiac gluten sensitivity or celiac disease. PMID:29118931
Muhammad, Amber A.; Shafiq, Yasir; Shah, Saima; Kumar, Naresh; Ahmed, Imran; Azam, Iqbal; Pasha, Omrana; Zaidi, Anita K. M.
2017-01-01
Abstract Background. Integrated Management of Childhood Illness recommends that young infants with isolated fast breathing be referred to a hospital for antibiotic treatment, which is often impractical in resource-limited settings. Additionally, antibiotics may be unnecessary for physiologic tachypnea in otherwise well newborns. We tested the hypothesis that ambulatory treatment with oral amoxicillin for 7 days was equivalent (similarity margin of 3%) to placebo in young infants with isolated fast breathing in primary care settings where hospital referral is often unfeasible. Methods. This randomized equivalence trial was conducted in 4 primary health centers of Karachi, Pakistan. Infants presenting with isolated fast breathing and oxygen saturation ≥90% were randomly assigned to receive either oral amoxicillin or placebo twice daily for 7 days. Enrolled infants were followed on days 1–8, 11, and 14. The primary outcome was treatment failure by day 8, analyzed per protocol. The trial was stopped by the data safety monitoring board due to higher treatment failure rate and the occurrence of 2 deaths in the placebo arm in an interim analysis. Results. Four hundred twenty-three infants fulfilled per protocol criteria in the amoxicillin arm and 426 in the placebo arm. Twelve infants (2.8%) had treatment failure in the amoxicillin arm and 25 (5.9%) in the placebo arm (risk difference, 3.1; P value .04). Two infants in the placebo arm died, whereas no deaths occurred in the amoxicillin arm. Other adverse outcomes, as well as the proportions of relapse, were evenly distributed across both study arms. Conclusions. This trial failed to show equivalence of placebo to amoxicillin in the management of isolated fast breathing without hypoxemia or other clinical signs of illness in term young infants. Clinical Trials Registration. NCT01533818. PMID:27941119
Pettersson, Henrik; Faager, Gun; Westerdahl, Elisabeth
2015-09-01
Breathing exercises after cardiac surgery are often performed in a sitting position. It is unknown whether oxygenation would be better in the standing position. The aim of this study was to evaluate oxygenation and subjective breathing ability during sitting vs standing performance of deep breathing exercises on the second day after cardiac surgery. Patients undergoing coronary artery bypass grafting (n = 189) were randomized to sitting (controls) or standing. Both groups performed 3 × 10 deep breaths with a positive expiratory pressure device. Peripheral oxygen saturation was measured before, directly after, and 15 min after the intervention. Subjective breathing ability, blood pressure, heart rate, and pain were assessed. Oxygenation improved significantly in the standing group compared with controls directly after the breathing exercises (p < 0.001) and after 15 min rest (p = 0.027). The standing group reported better deep breathing ability compared with controls (p = 0.004). A slightly increased heart rate was found in the standing group (p = 0.047). After cardiac surgery, breathing exercises with positive expiratory pressure, performed in a standing position, significantly improved oxygenation and subjective breathing ability compared with sitting performance. Performance of breathing exercises in the standing position is feasible and could be a valuable treatment for patients with postoperative hypoxaemia.
A reservoir nasal cannula improves protection given by oxygen during muscular exercise in COPD.
Arlati, S; Rolo, J; Micallef, E; Sacerdoti, C; Brambilla, I
1988-06-01
We verified the utility of an oxygen economizer (Pendant Oxymizer) in assuring greater protection than nasal prongs against worsening of oxyhemoglobin resting desaturation (delta SaO2) induced by muscular exercise in 16 patients (ten with chronic obstructive pulmonary disease [COPD] and six with restrictive pulmonary disease). This worsening was quantified as desaturation surface accumulated within five minutes of exercise and was expressed in arbitrary units (au). Each patient carried out the same exercise three times, in a randomized fashion (breathing air or breathing supplemental oxygen [3 L/min] delivered by either nasal prongs or by oxygen economizer). In patients with obstructive disease, delta SaO2 was reduced from 38 +/- 12.0 au when they were breathing air to 18.1 +/- 11.7 au when breathing oxygen by nasal prongs (p less than 0.001) and to 10.1 +/- 9.5 au when breathing oxygen by economizer (p less than 0.001). In patients with restrictive disease, delta SaO2 was reduced from 35.6 +/- 9.9 au when breathing air to 14.9 +/- 10.2 au breathing oxygen by nasal prongs (p less than 0.01) and to 13.7 +/- 10.3 au breathing oxygen by economizer (p less than 0.01). The difference between breathing by economizer and nasal prongs was significant (paired t-test; p less than 0.01) only in patients with COPD. One explanation could lie in the different values of the respiratory rate, which was significantly greater in patients with restrictive disease (20.7 +/- 1.2 breaths per minute at rest and 25.8 +/- 1.5 with exercise) than in patients with obstructive disease (15.3 +/- 1.2 breaths per minute at rest and 20.8 +/- 1.4 with exercise).
Gerbarg, Patricia L; Jacob, Vinita E; Stevens, Laurie; Bosworth, Brian P; Chabouni, Fatiha; DeFilippis, Ersilia M; Warren, Ryan; Trivellas, Myra; Patel, Priyanka V; Webb, Colleen D; Harbus, Michael D; Christos, Paul J; Brown, Richard P; Scherl, Ellen J
2015-12-01
This study evaluated the effects of the Breath-Body-Mind Workshop (BBMW) (breathing, movement, and meditation) on psychological and physical symptoms and inflammatory biomarkers in inflammatory bowel disease (IBD). Twenty-nine IBD patients from the Jill Roberts IBD Center were randomized to BBMW or an educational seminar. Beck Anxiety Inventory, Beck Depression Inventory, Brief Symptom Inventory 18, IBD Questionnaire, Perceived Disability Scale, Perceived Stress Questionnaire, Digestive Disease Acceptance Questionnaire, Brief Illness Perception Questionnaire, fecal calprotectin, C-reactive protein, and physiological measures were obtained at baseline and weeks 6 and 26. The BBMW group significantly improved between baseline and week 6 on Brief Symptom Inventory 18 (P = 0.02), Beck Anxiety Inventory (P = 0.02), and IBD Questionnaire (P = 0.01) and between baseline and week 26 on Brief Symptom Inventory 18 (P = 0.04), Beck Anxiety Inventory (P = 0.03), Beck Depression Inventory (P = 0.01), IBD Questionnaire (P = 0.01), Perceived Disability Scale (P = 0.001), and Perceived Stress Questionnaire (P = 0.01) by paired t tests. No significant changes occurred in the educational seminar group at week 6 or 26. By week 26, median C-reactive protein values decreased significantly in the BBMW group (P = 0.01 by Wilcoxon signed-rank test) versus no significant change in the educational seminar group. In patients with IBD, participation in the BBMW was associated with significant improvements in psychological and physical symptoms, quality of life, and C-reactive protein. Mind-body interventions, such as BBMW, which emphasize Voluntarily Regulated Breathing Practices, may have significant long-lasting benefits for IBD symptoms, anxiety, depression, quality of life, and inflammation. BBMW, a promising adjunctive treatment for IBD, warrants further study.
Breathing exercises in upper abdominal surgery: a systematic review and meta-analysis.
Grams, Samantha T; Ono, Lariane M; Noronha, Marcos A; Schivinski, Camila I S; Paulin, Elaine
2012-01-01
There is currently no consensus on the indication and benefits of breathing exercises for the prevention of postoperative pulmonary complications PPCs and for the recovery of pulmonary mechanics. To undertake a systematic review of randomized and quasi-randomized studies that assessed the effects of breathing exercises on the recovery of pulmonary function and prevention of PCCs after upper abdominal surgery UAS. We searched the Physiotherapy Evidence Database PEDro, Scientific Electronic Library Online SciELO, MEDLINE, and Cochrane Central Register of Controlled Trials. We included randomized controlled trials and quasi-randomized controlled trials on pre- and postoperative UAS patients, in which the primary intervention was breathing exercises without the use of incentive inspirometers. The methodological quality of the studies was rated according to the PEDro scale. Data on maximal respiratory pressures MIP and MEP, spirometry, diaphragm mobility, and postoperative complications were extracted and analyzed. Data were pooled in fixed-effect meta-analysis whenever possible. Six studies were used for analysis. Two meta-analyses including 66 participants each showed that, on the first day post-operative, the breathing exercises were likely to have induced MEP and MIP improvement treatment effects of 11.44 mmH2O (95%CI 0.88 to 22) and 11.78 mmH2O (95%CI 2.47 to 21.09), respectively. Breathing exercises are likely to have a beneficial effect on respiratory muscle strength in patients submitted to UAS, however the lack of good quality studies hinders a clear conclusion on the subject.
Yang, Jian-Feng; Fox, Mark; Chu, Hua; Zheng, Xia; Long, Yan-Qin; Pohl, Daniel; Fried, Michael; Dai, Ning
2015-01-01
AIM: To validate 4-sample lactose hydrogen breath testing (4SLHBT) compared to standard 13-sample LHBT in the clinical setting. METHODS: Irritable bowel syndrome patients with diarrhea (IBS-D) and healthy volunteers (HVs) were enrolled and received a 10 g, 20 g, or 40 g dose lactose hydrogen breath test (LHBT) in a randomized, double-blinded, controlled trial. The lactase gene promoter region was sequenced. Breath samples and symptoms were acquired at baseline and every 15 min for 3 h (13 measurements). The detection rates of lactose malabsorption (LM) and lactose intolerance (LI) for a 4SLHBT that acquired four measurements at 0, 90, 120, and 180 min from the same data set were compared with the results of standard LHBT. RESULTS: Sixty IBS-D patients and 60 HVs were studied. The genotype in all participants was C/C-13910. LM and LI detection rates increased with lactose dose from 10 g, 20 g to 40 g in both groups (P < 0.001). 4SLHBT showed excellent diagnostic concordance with standard LHBT (97%-100%, Kappa 0.815-0.942) with high sensitivity (90%-100%) and specificity (100%) at all three lactose doses in both groups. CONCLUSION: Reducing the number of measurements from 13 to 4 samples did not significantly impact on the accuracy of LHBT in health and IBS-D. 4SLHBT is a valid test for assessment of LM and LI in clinical practice. PMID:26140004
Yang, Jian-Feng; Fox, Mark; Chu, Hua; Zheng, Xia; Long, Yan-Qin; Pohl, Daniel; Fried, Michael; Dai, Ning
2015-06-28
To validate 4-sample lactose hydrogen breath testing (4SLHBT) compared to standard 13-sample LHBT in the clinical setting. Irritable bowel syndrome patients with diarrhea (IBS-D) and healthy volunteers (HVs) were enrolled and received a 10 g, 20 g, or 40 g dose lactose hydrogen breath test (LHBT) in a randomized, double-blinded, controlled trial. The lactase gene promoter region was sequenced. Breath samples and symptoms were acquired at baseline and every 15 min for 3 h (13 measurements). The detection rates of lactose malabsorption (LM) and lactose intolerance (LI) for a 4SLHBT that acquired four measurements at 0, 90, 120, and 180 min from the same data set were compared with the results of standard LHBT. Sixty IBS-D patients and 60 HVs were studied. The genotype in all participants was C/C-13910. LM and LI detection rates increased with lactose dose from 10 g, 20 g to 40 g in both groups (P < 0.001). 4SLHBT showed excellent diagnostic concordance with standard LHBT (97%-100%, Kappa 0.815-0.942) with high sensitivity (90%-100%) and specificity (100%) at all three lactose doses in both groups. Reducing the number of measurements from 13 to 4 samples did not significantly impact on the accuracy of LHBT in health and IBS-D. 4SLHBT is a valid test for assessment of LM and LI in clinical practice.
Peruzzo, Daiane Cristina; Salvador, Sérgio Luis; Sallum, Antonio Wilson; Nogueira-Filho, Getúlio da Rocha
2008-01-01
This study aimed to evaluate the effects of a flavor-containing dentifrice on the formation of volatile sulphur compounds (VSCs) in morning bad breath. A two-step, blinded, crossover, randomized study was carried out in 50 dental students with a healthy periodontium divided into two experimental groups: flavor-containing dentifrice (test) and non-flavor-containing dentifrice (control). The volunteers received the designated dentifrice and a new toothbrush for a 3 X/day brushing regimen for 2 periods of 30 days. A seven-day washout interval was used between the periods. The assessed parameters were: plaque index (PI), gingival index (GI), organoleptic breath scores (ORG), VSC levels (as measured by a portable sulphide monitor) before (H1) and after (H2) cleaning of the tongue, tongue coating (TC) wet weight and BANA test from TC samples. The intra-group analysis showed a decrease in ORG, from 3 to 2, after 30 days for the test group (p < 0.05). The inter-group analysis showed lower values in ORG, H1 and H2 for the test group (p < 0.05). There was no difference between the amount of TC between groups and the presence of flavor also did not interfere in the BANA results between groups (p > 0.05). These findings suggest that a flavor-containing dentifrice seems to prevent VSCs formation in morning bad breath regardless of the amount of TC in periodontally healthy subjects.
Barletta, Barbara; Yoonessi, Leila; Meinardi, Simone; Leu, Szu‐Yun; Radom‐Aizik, Shlomit; Randhawa, Inderpal; Nussbaum, Eliezer; Blake, Donald R.; Cooper, Dan M.
2015-01-01
Abstract Inhaled corticosteroids (ICS) and β2‐agonists are the primary pharmacotherapies of asthma management. However, suboptimal medication compliance is common in asthmatics and is associated with increased morbidity. We hypothesized that exhaled breath measurements of the aerosol used in the inhaled medications might prove useful as surrogate marker for asthma medication compliance. To explore this, 10 healthy controls were recruited and randomly assigned to ICS (Flovent HFA) or short acting bronchodilators (Proventil HFA). Both inhalers contain HFA‐134a as aerosol propellant. Exhaled breath sampling and pulmonary function tests were performed prior to the inhaler medication dispersion, immediately after inhalation, then at 2, 4, 6, 8, 24, and 48 hours postadministration. At baseline, mean (SD) levels of HFA‐134a in the breath were 252 (156) pptv. Immediately after inhalation, HFA‐134a breath levels increased to 300 × 106 pptv and were still well above ambient levels 24 hours postadministration. The calculated ratio of forced expiratory volume in 1 second over forced vital capacity did not change over time following inhaler administration. This study demonstrates, for the first time, that breath HFA‐134a levels can be used to assess inhaler medication compliance. It may also be used to evaluate how effectively the medicine is delivered. PMID:26155923
Breathing exercises with vagal biofeedback may benefit patients with functional dyspepsia.
Hjelland, Ina E; Svebak, Sven; Berstad, Arnold; Flatabø, Geir; Hausken, Trygve
2007-09-01
Many patients with functional dyspepsia (FD) have postprandial symptoms, impaired gastric accommodation and low vagal tone. The aim of this study was to improve vagal tone, and thereby also drinking capacity, intragastric volume and quality of life, using breathing exercises with vagal biofeedback. Forty FD patients were randomized to either a biofeedback group or a control group. The patients received similar information and care. Patients in the biofeedback group were trained in breathing exercises, 6 breaths/min, 5 min each day for 4 weeks, using specially designed software for vagal biofeedback. Effect variables included maximal drinking capacity using a drink test (Toro clear meat soup 100 ml/min), intragastric volume at maximal drinking capacity, respiratory sinus arrhythmia (RSA), skin conductance (SC) and dyspepsia-related quality of life scores. Drinking capacity and quality of life improved significantly more in the biofeedback group than in the control group (p=0.02 and p=0.01) without any significant change in baseline autonomic activity (RSA and SC) or intragastric volume. After the treatment period, RSA during breathing exercises was significantly correlated to drinking capacity (r=0.6, p=0.008). Breathing exercises with vagal biofeedback increased drinking capacity and improved quality of life in FD patients, but did not improve baseline vagal tone.
Cardiorespiratory interactions to external stimuli.
Bernardi, L; Porta, C; Spicuzza, L; Sleight, P
2005-09-01
Respiration is a powerful modulator of heart rate variability, and of baro- or chemo-reflex sensitivity. This occurs via a mechanical effect of breathing that synchronizes all cardiovascular variables at the respiratory rhythm, particularly when this occurs at a particular slow rate coincident with the Mayer waves in arterial pressure (approximately 6 cycles/min). Recitation of the rosary prayer (or of most mantras), induces a marked enhancement of these slow rhythms, whereas random verbalization or random breathing does not. This phenomenon in turn increases baroreflex sensitivity and reduces chemoreflex sensitivity, leading to increases in parasympathetic and reductions in sympathetic activity. The opposite can be seen during either verbalization or mental stress tests. Qualitatively similar effects can be obtained even by passive listening to more or less rhythmic auditory stimuli, such as music, and the speed of the rhythm (rather than the style) appears to be one of the main determinants of the cardiovascular and respiratory responses. These findings have clinical relevance. Appropriate modulation of breathing, can improve/restore autonomic control of cardiovascular and respiratory systems in relevant diseases such as hypertension and heart failure, and might therefore help improving exercise tolerance, quality of life, and ultimately, survival.
Soares, Léo G; Jonski, Grazyna; Tinoco, Eduardo M B; Young, Alix
2015-04-01
Zinc (Zn) reduces the formation of volatile sulphur compounds (VSCs) associated with oral malodour. Although strontium (Sr) is included in some products for reducing dental hypersensitivity, it may also have anti-halitosis properties. This randomized, double-blind, cross-over clinical study compared the anti-VSC effect of brushing with commercial toothpastes and rinses containing Zn and Sr. The volunteers (n = 30) either brushed/rinsed with/without tongue brushing using Zn-containing toothpaste/rinse, Sr-containing toothpaste/rinse, or placebo (control). Volatile sulphur compounds [hydrogen sulphide (H2 S) and methyl mercaptan (CH3 SH)] were measured, in morning breath, using gas chromatography. The anti-VSC effects of the test toothpastes and test rinses were significantly better than the anti-VSC effects of the respective controls. Toothbrushing with test toothpastes gave median reductions, compared with the control, of 70% for H2 S and 55-57% for CH3 SH. Rinsing with the Sr- and Zn-containing solutions had the same anti-VSC effect as toothbrushing and tooth- and tongue brushing with the Sr- and Zn-containing toothpastes. Zinc-containing rinse resulted in a significantly higher median salivary level of Zn compared with brushing with Zn-containing toothpaste, although this effect did not correlate with the anti-VSC effect. It can be concluded that the Sr- and Zn-containing toothpastes and the Zn- and Sr-containing rinses, when used in the evening, are equally effective in reducing morning-breath VSCs the following day. © 2015 Eur J Oral Sci.
Germonpré, Peter; Balestra, Costantino; Hemelryck, Walter; Buzzacott, Peter; Lafère, Pierre
2017-05-01
Divers try to limit risks associated with their sport, for instance by breathing enriched air nitrox (EANx) instead of air. This double blinded, randomized trial was designed to see if the use of EANx could effectively improve cognitive performance while diving. Eight volunteers performed two no-decompression dry dives breathing air or EANx for 20 min at 0.4 MPa. Cognitive functions were assessed with a computerized test battery, including MathProc and Ptrail. Measurements were taken before the dive, upon arrival and after 15 min at depth, upon surfacing, and at 30 min postdive. After each dive subjects were asked to identify the gas they had just breathed. Identification of the breathing gas was not possible on subjective assessment alone, while cognitive assessments showed significantly better performance while breathing EANx. Before the dives, breathing air, mean time to complete the task was 1795 ms for MathProc and 1905 ms for Ptrail. When arriving at depth MathProc took 1616 ms on air and 1523 ms on EANx, and Ptrail took 1318 ms on air and and 1356 ms on EANx, followed 15 min later by significant performance inhibition while breathing air during the ascent and the postdive phase, supporting the concept of late dive/postdive impairment. The results suggest that EANx could protect against decreased neuro-cognitive performance induced by inert gas narcosis. It was not possible for blinded divers to identify which gas they were breathing and differences in postdive fatigue between air and EANx diving deserve further investigation.Germonpré P, Balestra C, Hemelryck W, Buzzacott P, Lafère P. Objective vs. subjective evaluation of cognitive performance during 0.4-MPa dives breathing air or nitrox. Aerosp Med Hum Perform. 2017; 88(5):469-475.
Flute ``breath support'' perception and its acoustical correlates
NASA Astrophysics Data System (ADS)
Cossette, Isabelle A.; Sabourin, Patrick
2004-05-01
Music educators and performers commonly refer to ``breath support'' in flute playing, yet the term ``support'' is neither well-defined nor consistently used. Different breathing strategies used by professional flautists who were instructed to play with and without support were previously identified by the authors. In the current study, 14 musical excerpts with and without support were recorded by five professional flautists. Eleven professional flautists listened to the recordings in a random order and ranked (1 to 6) how much of the following sound qualities they judged to be in each example: support, intonation, control and musical expressiveness. Answers to the test showed that musical expressiveness was associated more closely with the supported excerpts than the answers about support itself. The ratings for each sound quality were highly intercorrelated. Acoustical parameters were analyzed (frequency and centroid variation within each note) and compared with the results of the perception test in order to better understand how the acoustical and psychological variables were related. The acoustical analysis of the central part of the notes did not show evident correlation with the answers of the perception test. [Work funded by the Social Sciences and Humanities Research Council of Canada.
49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...
49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 1 2011-10-01 2011-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...
Hydrogen breath test in schoolchildren.
Douwes, A C; Schaap, C; van der Klei-van Moorsel, J M
1985-01-01
The frequency of negative hydrogen breath tests due to colonic bacterial flora which are unable to produce hydrogen was determined after oral lactulose challenge in 98 healthy Dutch schoolchildren. There was a negative result in 9.2%. The probability of a false normal lactose breath test (1:77) was calculated from these results together with those from a separate group of children with lactose malabsorption (also determined by hydrogen breath test). A study of siblings and mothers of subjects with a negative breath test did not show familial clustering of this condition. Faecal incubation tests with various sugars showed an increase in breath hydrogen greater than 100 parts per million in those with a positive breath test while subjects with a negative breath test also had a negative faecal incubation test. The frequency of a false negative hydrogen breath test was higher than previously reported, but this does not affect the superiority of this method of testing over the conventional blood glucose determination. PMID:4004310
The effect of breath freshener strips on two types of breath alcohol testing instruments.
Moore, Ronald L; Guillen, Jennifer
2004-07-01
The potential for breath freshener strips to interfere with the accuracy of a breath alcohol test was studied. Twelve varieties of breath freshener strips from five manufacturers were examined. Breath tests were conducted using the infrared based BAC DataMaster or the fuel cell based Alco-Sensor IV-XL, 30 and 150 seconds after placing a breath strip on the tongue. No effect was observed using the Alco-Sensor system. Some of the strips gave a small reading at 30 seconds (less than or equal to 0.010 g/210 L apparent alcohol) using the DataMaster. Readings on the DataMaster returned to zero by the 150 second test. A proper pre-test observation and deprivation period should prevent any interference from breath freshener strips on breath alcohol testing.
21 CFR 862.3050 - Breath-alcohol test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Breath-alcohol test system. 862.3050 Section 862....3050 Breath-alcohol test system. (a) Identification. A breath-alcohol test system is a device intened to measure alcohol in the human breath. Measurements obtained by this device are used in the...
21 CFR 862.3050 - Breath-alcohol test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breath-alcohol test system. 862.3050 Section 862....3050 Breath-alcohol test system. (a) Identification. A breath-alcohol test system is a device intened to measure alcohol in the human breath. Measurements obtained by this device are used in the...
Effect of a simethicone-containing tablet on colonic gas elimination in breath.
Lifschitz, C H; Irving, C S; Smith, E O
1985-05-01
The effect of a tablet containing the antiflatulent, simethicone, on intestinal hydrogen (H2) elimination in breath was studied. In three trials, normal subjects (age 12-52 years) received, on subsequent days, lactulose or lactulose with two tablets of either simethicone or placebo in randomized order. Breath samples were collected over 210 min and analyzed by gas chromatography for H2. The time course of H2 expiration above baseline levels was calculated and compared for the three tests. No significant differences in transit time were found. Cumulative H2 expiration was significantly lower after simethicone compared to placebo. H2 production from stool incubated with simethicone or placebo indicated that the drug had no effect in reducing the fermentative production of H2 in vitro. Interestingly, the vehicle present in the tablets could be fermented by intestinal bacteria. Simethicone reduced the amount of H2 eliminated in breath, but this effect was offset partially by H2 production from the fermentation of unabsorbable substances used in the formulation of the tablets.
2015-10-01
randomized controlled trial, we will objectively measure sleep disordered breathing ( SDB ) in chronic SCI patients using portable sleep studies, and...systematically evaluate the association between SDB , cognitive performance, mood, pain, and CV measures. We will randomize participants to 4 months of PAP...TERMS SDB , SCI, PAP, CV 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON USAMRMC a
2015-11-30
randomized controlled trial, we will objectively measure sleep disordered breathing ( SDB ) in chronic SCI patients using portable sleep studies, and...systematically evaluate the association between SDB , cognitive performance, mood, pain, and CV measures. We will randomize participants to 4 months of PAP...TERMS SDB , SCI, PAP, CV 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON USAMRMC a
The glucose breath test: a diagnostic test for small bowel stricture(s) in Crohn's disease.
Mishkin, Daniel; Boston, Francis M; Blank, David; Yalovsky, Morty; Mishkin, Seymour
2002-03-01
The aim of this study was to determine whether an indirect noninvasive indicator of proximal bacterial overgrowth, the glucose breath test, was of diagnostic value in inflammatory bowel disease. Twenty four of 71 Crohn's disease patients tested had a positive glucose breath test. No statistical conclusions could be drawn between the Crohn's disease activity index and glucose breath test status. Of patients with radiologic evidence of small bowel stricture(s), 96.0% had a positive glucose breath test, while only one of 46 negative glucose breath test patients had a stricture. The positive and negative predictive values for a positive glucose breath test as an indicator of stricture formation were 96.0% and 97.8%, respectively. This correlation was not altered in Crohn's disease patients with fistulae or status postresection of the terminal ileum. The data in ulcerative colitis were nondiagnostic. In conclusion, the glucose breath test appears to be an accurate noninvasive inexpensive diagnostic test for small bowel stricture(s) and secondary bacterial overgrowth in Crohn's disease.
Rifaximin: The Revolutionary Antibiotic Approach for Irritable Bowel Syndrome.
Triantafyllou, Konstantinos; Sioulas, Athanasios D; Giamarellos-Bourboulis, Evangelos J
2015-01-01
A large number of clinical studies using breath testing and a smaller number of studies using quantitative cultures of the upper small intestine established a link between irritable bowel syndrome (IBS) and small intestinal bacterial overgrowth (SIBO). A series of 12 studies both prospective and retrospective in design in a population of patients with SIBO without IBS showed that the non-absorbable antibiotic rifaximin can eradicate SIBO as proved through decrease of the exhaled hydrogen and methane in breath tests. The efficacy of rifaximin was superior over the comparator treatment in most of these studies. Based on these findings, short course rifaximin was tested in various concentrations in eight open-label trials in patients with IBS and proven SIBO by breath test. Similar efficacy of rifaximin was shown in SIBO eradication; this was accompanied by improvement of the global score for IBS symptoms. Finally, five double-blind randomized clinical trials were conducted in patients with IBS; four were placebo-controlled. The larger trials were TARGET 1 and TARGET 2 studies testing rifaximin at a regimen of 550 mg tid for 14 days. All trials showed a significant superiority of rifaximin over comparator for the improvement of global symptoms of IBS and bloating. Although the aforementioned results render rifaximin a revolutionary therapeutic approach for IBS, several concerns on induction of antimicrobial resistant flora remain.
Latshang, Tsogyal D.; Lo Cascio, Christian M.; Stöwhas, Anne-Christin; Grimm, Mirjam; Stadelmann, Katrin; Tesler, Noemi; Achermann, Peter; Huber, Reto; Kohler, Malcolm; Bloch, Konrad E.
2013-01-01
Study Objectives: Newcomers at high altitude (> 3,000 m) experience periodic breathing, sleep disturbances, and impaired cognitive performance. Whether similar adverse effects occur at lower elevations is uncertain, although numerous lowlanders travel to moderate altitude for professional or recreational activities. We evaluated the hypothesis that nocturnal breathing, sleep, and cognitive performance of lowlanders are impaired at moderate altitude. Design: Randomized crossover trial. Setting: University hospital at 490 m, Swiss mountain villages at 1,630 m and 2,590 m. Participants: Fifty-one healthy men, median (quartiles) age 24 y (20-28 y), living below 800 m. Interventions: Studies at Zurich (490 m) and during 4 consecutive days at 1,630 m and 2,590 m, respectively, 2 days each. The order of altitude exposure was randomized. Polysomnography, psychomotor vigilance tests (PVT), the number back test, several other tests of cognitive performance, and questionnaires were evaluated. Measurements and Results: The median (quartiles) apnea-hypopnea index at 490 m was 4.6/h (2.3; 7.9), values at 1,630 and 2,590 m, day 1 and 2, respectively, were 7.0/h (4.1; 12.6), 5.4/h (3.5; 10.5), 13.1/h (6.7; 32.1), and 8.0/h (4.4; 23.1); corresponding values of mean nocturnal oxygen saturation were 96% (95; 96), 94% (93; 95), 94% (93; 95), 90% (89; 91), 91% (90; 92), P < 0.05 versus 490 m, all instances. Slow wave sleep on the first night at 2,590 m was 21% (18; 25) versus 24% (20; 27) at 490 m (P < 0.05). Psychomotor vigilance and various other measures of cognitive performance did not change significantly. Conclusions: Healthy men acutely exposed during 4 days to hypoxemia at 1,630 m and 2,590 m reveal a considerable amount of periodic breathing and sleep disturbances. However, no significant effects on psychomotor reaction speed or cognitive performance were observed. Clinical Trials Registration: Clinicaltrials.gov: NCT01130948. Citation: Latshang TD; Lo Cascio CM; Stöwhas AC; Grimm M; Stadelmann K; Tesler N; Achermann P; Huber R; Kohler M; Bloch KE. Are nocturnal breathing, sleep, and cognitive performance impaired at moderate altitude (1,630-2,590 m)? SLEEP 2013;36(12):1969-1976. PMID:24293773
Holtmeier, Julia; Leuschner, Maria; Schneider, Arne; Leuschner, Ulrich; Caspary, Wolfgang F; Braden, Barbara
2006-11-01
The 13C-methacetin breath test quantitatively evaluates cytochrome P450-dependent liver function. The 13C-galactose breath test non-invasively measures the galactose oxidation capacity of the liver. The aim of this study was to find out whether these breath tests are sensitive parameters also in non-cirrhotic patients with primary biliary cirrhosis. Nineteen patients with early-stage primary biliary cirrhosis (no cirrhotic alterations in the liver biopsy, Ludwig stage I-III) and 20 healthy controls underwent the 13C-methacetin and 13C-galactose breath tests. Patients with primary biliary cirrhosis metabolized less 13C-methacetin than controls (cumulative recovery within 30 min 7.5+/-2.4% versus 14.0+/-2.6%; p < 0.001). When a cut-off > 9.8% was used for the cumulative recovery after 30 min, the methacetin breath test reached 84.2% sensitivity and 95.0 specificity. In the 13C-galactose breath test, the percentage recovery at 60 min in patients was 3.1+/-1.3%/h, and 6.3+/-1.1%/h in controls (p < 0.001). Using a cut-off > 4.7%/h, the galactose breath test reached 89.5% sensitivity and 95.0 specificity. In non-cirrhotic, early-stage, primary biliary cirrhosis the 13C-methacetin breath test and the 13C-galactose breath test reliably indicate decreased liver function. The 13C-galactose breath test can also predict the histological score.
The effects of relaxation breathing on procedural pain and anxiety during burn care.
Park, Eunok; Oh, Hyunjin; Kim, Taeim
2013-09-01
Burn patients experience high levels of pain and anxiety during dressing changes. Relaxation breathing is a simple behavioral intervention to manage pain and anxiety. However, the information about the effects of relaxation breathing on pain and anxiety levels for burn patients during dressing changes is limited. This study followed a quasi-experimental, pretest-posttest comparison group design without random assignment to groups. A total of 64 burn patients from Daejeon, South Korea were recruited by a convenience sequential sampling approach. With institutional approval and written consent, the experimental group practiced relaxation breathing during dressing change procedures. Data were collected from June to September 2011 using a VAS for pain and a VAS-A for anxiety. The homogeneity test was used to detect any significant group differences in the demographic data and pretest measures. The pain scores significantly differed between the 2 groups after intervention (RB group vs. control group, P=.01) and over time (pretest vs. posttest, P=.001). The anxiety scores significantly differed between the 2 groups (P=.01) and over time (P=.02). Relaxation breathing is a simple and inexpensive technique nurses can use to help burn patients manage pain and anxiety during dressing changes. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Controlled-frequency breath swimming improves swimming performance and running economy.
Lavin, K M; Guenette, J A; Smoliga, J M; Zavorsky, G S
2015-02-01
Respiratory muscle fatigue can negatively impact athletic performance, but swimming has beneficial effects on the respiratory system and may reduce susceptibility to fatigue. Limiting breath frequency during swimming further stresses the respiratory system through hypercapnia and mechanical loading and may lead to appreciable improvements in respiratory muscle strength. This study assessed the effects of controlled-frequency breath (CFB) swimming on pulmonary function. Eighteen subjects (10 men), average (standard deviation) age 25 (6) years, body mass index 24.4 (3.7) kg/m(2), underwent baseline testing to assess pulmonary function, running economy, aerobic capacity, and swimming performance. Subjects were then randomized to either CFB or stroke-matched (SM) condition. Subjects completed 12 training sessions, in which CFB subjects took two breaths per length and SM subjects took seven. Post-training, maximum expiratory pressure improved by 11% (15) for all 18 subjects (P < 0.05) while maximum inspiratory pressure was unchanged. Running economy improved by 6 (9)% in CFB following training (P < 0.05). Forced vital capacity increased by 4% (4) in SM (P < 0.05) and was unchanged in CFB. These findings suggest that limiting breath frequency during swimming may improve muscular oxygen utilization during terrestrial exercise in novice swimmers. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Comparison of breath testing with fructose and high fructose corn syrups in health and IBS
Skoog, S. M.; Bharucha, A. E.; Zinsmeister, A. R.
2008-01-01
Although incomplete fructose absorption has been implicated to cause gastrointestinal symptoms, foods containing high fructose corn syrup (HFCS) contain glucose. Glucose increases fructose absorption in healthy subjects. Our hypothesis was that fructose intolerance is less prevalent after HFCS consumption compared to fructose alone in healthy subjects and irritable bowel syndrome (IBS). Breath hydrogen levels and gastrointestinal symptoms were assessed after 40 g of fructose (12% solution) prepared either in water or as HFCS, administered in double-blind randomized order on 2 days in 20 healthy subjects and 30 patients with IBS. Gastrointestinal symptoms were recorded on 100-mm Visual Analogue Scales. Breath hydrogen excretion was more frequently abnormal (P < 0.01) after fructose (68%) than HFCS (26%) in controls and patients. Fructose intolerance (i.e. abnormal breath test and symptoms) was more prevalent after fructose than HFCS in healthy subjects (25% vs 0%, P = 0.002) and patients (40% vs 7%, P = 0.062). Scores for several symptoms (e.g. bloating r = 0.35) were correlated (P ≤ 0.01) to peak breath hydrogen excretion after fructose but not HFCS; in the fructose group, this association did not differ between healthy subjects and patients. Symptoms were not significantly different after fructose compared to HFCS. Fructose intolerance is more prevalent with fructose alone than with HFCS in health and in IBS. The prevalence of fructose intolerance is not significantly different between health and IBS. Current methods for identifying fructose intolerance should be modified to more closely reproduce fructose ingestion in daily life. PMID:18221251
Comparison of breath testing with fructose and high fructose corn syrups in health and IBS.
Skoog, S M; Bharucha, A E; Zinsmeister, A R
2008-05-01
Although incomplete fructose absorption has been implicated to cause gastrointestinal symptoms, foods containing high fructose corn syrup (HFCS) contain glucose. Glucose increases fructose absorption in healthy subjects. Our hypothesis was that fructose intolerance is less prevalent after HFCS consumption compared to fructose alone in healthy subjects and irritable bowel syndrome (IBS). Breath hydrogen levels and gastrointestinal symptoms were assessed after 40 g of fructose (12% solution) prepared either in water or as HFCS, administered in double-blind randomized order on 2 days in 20 healthy subjects and 30 patients with IBS. Gastrointestinal symptoms were recorded on 100-mm Visual Analogue Scales. Breath hydrogen excretion was more frequently abnormal (P < 0.01) after fructose (68%) than HFCS (26%) in controls and patients. Fructose intolerance (i.e. abnormal breath test and symptoms) was more prevalent after fructose than HFCS in healthy subjects (25% vs. 0%, P = 0.002) and patients (40% vs. 7%, P = 0.062). Scores for several symptoms (e.g. bloating r = 0.35) were correlated (P < or = 0.01) to peak breath hydrogen excretion after fructose but not HFCS; in the fructose group, this association did not differ between healthy subjects and patients. Symptoms were not significantly different after fructose compared to HFCS. Fructose intolerance is more prevalent with fructose alone than with HFCS in health and in IBS. The prevalence of fructose intolerance is not significantly different between health and IBS. Current methods for identifying fructose intolerance should be modified to more closely reproduce fructose ingestion in daily life.
Festi, D.; Capodicasa, S.; Sandri, L.; Colaiocco-Ferrante, L.; Staniscia, T.; Vitacolonna, E.; Vestito, A.; Simoni, P.; Mazzella, G.; Portincasa, P.; Roda, E.; Colecchia, A.
2005-01-01
AIM: To evaluate and compare the clinical usefulness of 13C-phenylalanine and 13C-methacetin breath tests in quantitating functional hepatic mass in patients with chronic liver disease and to further compare these results with those of conventional tests, Child-Pugh score and serum bile acid levels. METHODS: One hundred and forty patients (50 HCV- related chronic hepatitis, 90 liver cirrhosis patients) and 40 matched healthy controls were studied. Both breath test and routine liver test, serum levels of cholic and chenodeoxycholic acid conjugates were evaluated. RESULTS: Methacetin breath test, expressed as 60 min cumulative percent of oxidation, discriminated the hepatic functional capacity not only between controls and liver disease patients, but also between different categories of chronic liver disease patients. Methacetin breath test was correlated with liver function tests and serum bile acids. Furthermore, methacetin breath test, as well as serum bile acids, were highly predictive of Child-Pugh scores. The diagnostic power of phenylalanine breath test was always less than that of methacetin breath test. CONCLUSION: Methacetin breath test represents a safe and accurate diagnostic tool in the evaluation of hepatic functional mass in chronic liver disease patients. PMID:15609414
49 CFR 219.206 - FRA access to breath test results.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...
49 CFR 219.206 - FRA access to breath test results.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...
49 CFR 219.206 - FRA access to breath test results.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...
49 CFR 219.206 - FRA access to breath test results.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...
49 CFR 219.206 - FRA access to breath test results.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...
Freire-Tellado, Miguel; Navarro-Patón, Rubén; Pavón-Prieto, Maria Del Pilar; Fernández-López, Marta; Mateos-Lorenzo, Javier; López-Fórneas, Ivan
2017-06-01
Resuscitation guidelines endorse unconscious and normally breathing out-of-hospital victims to be placed in the recovery position to secure airway patency, but recently a debate has been opened as to whether the recovery position threatens the cardiac arrest victim's safety assessment and delays the start of cardiopulmonary resuscitation. To compare the assessment of the victim's breathing arrest while placed in the recovery position versus maintaining an open airway with the continuous head tilt and chin lift technique to know whether the recovery position delays the cardiac arrest victim's assessment and the start of cardiopulmonary resuscitation. Basic life support-trained university students were randomly divided into two groups: one received a standardized cardiopulmonary resuscitation refresher course including the recovery position and the other received a modified cardiopulmonary resuscitation course using continuous head tilt and chin lift for unconscious and spontaneously breathing patients. A human simulation test to evaluate the victim's breathing assessment was performed a week later. In total, 59 participants with an average age of 21.9 years were included. Only 14 of 27 (51.85%) students in the recovery position group versus 23 of 28 (82.14%) in the head tilt and chin lift group p=0.006 (OR 6.571) detected breathing arrest within 2min. The recovery position hindered breathing assessment, delayed breathing arrest identification and the initiation of cardiac compressions, and significantly increased the likelihood of not starting cardiopulmonary resuscitation when compared to the results shown when the continuous head tilt and chin lift technique was used. Copyright © 2017 Elsevier B.V. All rights reserved.
Drinking and driving in southeastern Brazil: results from a roadside survey study.
Campos, Valdir Ribeiro; de Souza E Silva, Rebeca; Duailibi, Sérgio; Laranjeira, Ronaldo; Palacios, Ester Nakamura; Grube, Joel W; Pinsky, Ilana
2013-01-01
The objective of this study is to present data from a roadside survey study on drinking and driving and alcohol consumption in southeastern Brazil. A cross-sectional roadside survey study using a questionnaire and breathalyzer data is the method used to determine the prevalence of drinking and driving and to examine whether socio-demographic characteristics and drivers' behavior, attitude and alcohol consumption predicted positive blood alcohol content (BAC). The data were gathered from 2005 to 2007 through roadside surveys conducted on high volume public roads in four cities in southeastern Brazil. A total of 4182 randomly selected drivers took part in the research. Of these drivers, 3488 (83.4%) completed the questionnaire and agreed to take a breath test. Overall, 24.6% of drivers had a detectable blood alcohol concentration (BAC) and 15.9% had a BAC above the legal limit (0.6g/l) at the time of the study. Logistic regression controlling for locale (city), sex, age and marital status was used to predict whether each driver would present a positive breath test. Socio-demographic characteristics, driving behaviors and attitudes, and alcohol consumption patterns were included as predictors. These analyses indicated that those who believed drinking and driving was a serious offense were about two-thirds as likely to have a positive breath test, and that drivers reporting a pattern of regular alcohol use were three times as likely to have a positive breath test. These findings indicate that drinking and driving is relatively common in Brazil, and that it occurs considerably more frequently than similar surveys suggest, is the case in other countries. Copyright © 2012 Elsevier Ltd. All rights reserved.
Roche-Campo, Ferran; Vignaux, Laurence; Galia, Fabrice; Lyazidi, Aissam; Vargas, Frédéric; Texereau, Joëlle; Apiou-Sbirlea, Gabriela; Jolliet, Philippe; Brochard, Laurent
2011-11-01
To evaluate the efficacy of delivering a mixture of helium and oxygen gas (He–O2) in spontaneous ventilation. Three high oxygen flow reservoir masks were tested: the Heliox21, specifically designed for helium; the Hi-Ox80 mask, with an inspiratory and an expiratory valve; and a standard high-concentration face mask. This prospective randomized crossover study was performed in six healthy volunteers in a laboratory setting. Volunteers breathed a mixture of 78% He/22% O2 through each of the masks under two different breathing conditions (rest and hyperventilation: minute ventilation of 14.9 ± 6.1 and 26.7 ± 8.7 L min(−1), respectively) and four different He–O2 flow rates (7, 10, 12, and 15 L min(−1)). A nasopharyngeal catheter was used to estimate He pharyngeal concentration (Fp [He]) in the airways in order to determine the percentage of contamination with room air (% air cont) at end-expiration. Under all testing conditions, the Hi-Ox80 mask presented a significantly lower % air cont. During resting breathing pattern, a Fp [He] higher than 50% was achieved in 54% of the tests performed with the Hi-Ox80 mask compared to 29% for the Heliox21 mask and only 17% for the standard mask. At hyperventilation, a Fp [He] higher than 50% was achieved in 17% of the tests performed with the Hi-Ox mask compared to 4% for the other two masks. He–O2 administration via the usual high-concentration reservoir masks results in significant dilution by room air. The Hi-Ox80 mask minimized room air contamination and much more frequently achieved a pharyngeal He concentration higher than 50%.
Toivanen, H; Länsimies, E; Jokela, V; Hänninen, O
1993-10-01
The work-related strain of 50 female hospital cleaners and 48 female bank employees was recorded during a period of rationalization in the workplace, and the effect of daily relaxation to help the workers cope was tested. The subjects were arranged into age-matched pairs and randomly allocated into intervention and reference groups. The intervention period lasted six months. The relaxation method was brief and easily introduced as an alternative break in the workplace. Each training session lasted 15 min. A microcomputer-based system was used to record heart rate variability in response to quiet breathing, the Valsalva maneuver, deep breathing, and active orthostatic tests. Cardiac reflexes indicated that occupational strain (especially of a mental nature) caused the functioning of the autonomic nervous system to deteriorate. Regular deep relaxation normalized the function and improved the ability to cope.
Duddy, Fergus A; Weissman, Jake; Lee, Rich A; Paranjpe, Avina; Johnson, James D; Cohenca, Nestor
2012-08-01
Prevention of traumatic dental injuries relies on the identification of etiologic factors and the use of protective devices during contact sports. Mouthguards are considered to be an effective and cost-efficient device aimed at buffering the impacts or blows that might otherwise cause moderate to severe dental and maxillofacial injuries. Interestingly, besides their role in preventing injury, some authors claim that mouthguards can enhance athletic performance. Thus, the purpose of this controlled randomized trial was to evaluate and compare the effect of two different types of mouthguards on the athletic performance and strength of collegiate athletes. Eighteen college athletes ranging from 19 to 23 years participated in this study. Devices tested in this study included an over-the-counter boil-and-bite mouthguard (O-Flow™ Max Under Armour®) (UA) and a custom-made mouthguard (CM). Physical tests were carefully selected by the head athletic trainer and aimed at evaluating the strength and performance. The following sequence was carried out on each test day: (i) 3-stroke maximum power ergometer test, (ii) 1-min ergometer test, and (iii) a 1600-m run. A random assignment was developed to test all three experimental groups on each test day. Following the tests, each athlete completed a brief anonymous survey aimed at evaluating the athletes' overall satisfaction with each type of mouthguard. Custom-made mouthguards had no detrimental effect on athletic strength and performance and were reported by the athletes as being comfortable and not causing difficulty in breathing. In contrast, boil-and-bite mouthguards did not perform as well and were reported as being uncomfortable and causing breathing difficulties. Based on the results of this study, the use of custom-made mouthguards should be encouraged in contact sports as a protective measure, without concern for any negative effect on the athletic performance of the athletes. © 2012 John Wiley & Sons A/S.
Results of the first semi-annual qualification testing of devices to measure breath alcohol
DOT National Transportation Integrated Search
1975-01-01
Eight evidential breath testers were performance tested according to the Standard for Devices to Measure Breath Alcohol Federal Register, Vol 38, No. 212, November 5, 1973. In addition, a prototype breath tester not commercially available was tested....
Bergmann, Lars; Martini, Stefan; Kesselmeier, Miriam; Armbruster, Wolf; Notheisen, Thomas; Adamzik, Michael; Eichholz, Rϋdiger
2016-07-29
Interscalene brachial plexus (ISB) block is often associated with phrenic nerve block and diaphragmatic paresis. The goal of our study was to test if the anterior or the posterior ultrasound guided approach of the ISB is associated with a lower incidence of phrenic nerve blocks and impaired lung function. This was a prospective, randomized and single-blinded study of 84 patients scheduled for elective shoulder surgery who fullfilled the inclusion and exclusion critereria. Patients were randomized in two groups to receive either the anterior (n = 42) or the posterior (n = 42) approach for ISB. Clinical data were recorded. In both groups patients received ISB with a total injection volume of 15 ml of ropivacaine 1 %. Spirometry was conducted at baseline (T0) and 30 min (T30) after accomplishing the block. Changes in spirometrical variables between T0 and T30 were investigated by Wilcoxon signed-rank test for each puncture approach. The temporal difference between the posterior and the anterior puncture approach groups were again analyzed by the Wilcoxon-Mann-Whitney test. The spirometric results showed a significant decrease in vital capacity, forced expiratory volume per second, and maximum nasal inspiratory breathing after the Interscalene brachial plexus block; indicating a phrenic nerve block (p <0.001, Wilcoxon signed-rank). A significant difference in the development of the spirometric parameters between the anterior and the posterior group could not be identified (Wilcoxon-Mann-Whitney test). Despite the changes in spirometry, no cases of dyspnea were reported. A different site of injection (anterior or posterior) did not show an effect in reducing the cervical block spread of the local anesthetic and the incidence of phrenic nerve blocks during during ultrasound guided Interscalene brachial plexus block. Clinical breathing effects of phrenic nerve blocks are, however, usually well compensated, and subjective dyspnea did not occur in our patients. German Clinical Trials Register (DRKS number 00009908 , registered 26 January 2016).
NASA Astrophysics Data System (ADS)
Wisham, M.
2017-12-01
Breathing issues befall most asthmatics. However, the symptoms are not caused randomly. Particulate matter is a cause that has been collected and sampled at several bus stops. The following experiment provides the results of collected particulate matter in several locations around LSU.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glide-Hurst, Carri K.; Gopan, Ellen; Department of Radiation Oncology Wayne State University, Detroit, MI
2010-07-01
Purpose: To evaluate intra- and interfraction variability of tumor and lung volume and position using a hybrid active breath-hold gating technique. Methods and Materials: A total of 159 repeat normal inspiration active breath-hold CTs were acquired weekly during radiotherapy for 9 lung cancer patients (12-21 scans per patient). A physician delineated the gross tumor volume (GTV), lungs, and spinal cord on the first breath-hold CT, and contours were propagated semiautomatically. Intra- and interfraction variability of tumor and lung position and volume were evaluated. Tumor centroid and border variability were quantified. Results: On average, intrafraction variability of lung and GTV centroidmore » position was <2.0 mm. Interfraction population variability was 3.6-6.7 mm (systematic) and 3.1-3.9 mm (random) for the GTV centroid and 1.0-3.3 mm (systematic) and 1.5-2.6 mm (random) for the lungs. Tumor volume regressed 44.6% {+-} 23.2%. Gross tumor volume border variability was patient specific and demonstrated anisotropic shape change in some subjects. Interfraction GTV positional variability was associated with tumor volume regression and contralateral lung volume (p < 0.05). Inter-breath-hold reproducibility was unaffected by time point in the treatment course (p > 0.1). Increases in free-breathing tidal volume were associated with increases in breath-hold ipsilateral lung volume (p < 0.05). Conclusions: The breath-hold technique was reproducible within 2 mm during each fraction. Interfraction variability of GTV position and shape was substantial because of tumor volume and breath-hold lung volume change during therapy. These results support the feasibility of a hybrid breath-hold gating technique and suggest that online image guidance would be beneficial.« less
Ferris, Jason; Mazerolle, Lorraine; King, Mark; Bates, Lyndel; Bennett, Sarah; Devaney, Madonna
2013-11-01
In this paper we explore the relationship between monthly random breath testing (RBT) rates (per 1000 licensed drivers) and alcohol-related traffic crash (ARTC) rates over time, across two Australian states: Queensland and Western Australia. We analyse the RBT, ARTC and licensed driver rates across 12 years; however, due to administrative restrictions, we model ARTC rates against RBT rates for the period July 2004 to June 2009. The Queensland data reveals that the monthly ARTC rate is almost flat over the five year period. Based on the results of the analysis, an average of 5.5 ARTCs per 100,000 licensed drivers are observed across the study period. For the same period, the monthly rate of RBTs per 1000 licensed drivers is observed to be decreasing across the study with the results of the analysis revealing no significant variations in the data. The comparison between Western Australia and Queensland shows that Queensland's ARTC monthly percent change (MPC) is 0.014 compared to the MPC of 0.47 for Western Australia. While Queensland maintains a relatively flat ARTC rate, the ARTC rate in Western Australia is increasing. Our analysis reveals an inverse relationship between ARTC RBT rates, that for every 10% increase in the percentage of RBTs to licensed driver there is a 0.15 decrease in the rate of ARTCs per 100,000 licenced drivers. Moreover, in Western Australia, if the 2011 ratio of 1:2 (RBTs to annual number of licensed drivers) were to double to a ratio of 1:1, we estimate the number of monthly ARTCs would reduce by approximately 15. Based on these findings we believe that as the number of RBTs conducted increases the number of drivers willing to risk being detected for drinking driving decreases, because the perceived risk of being detected is considered greater. This is turn results in the number of ARTCs diminishing. The results of this study provide an important evidence base for policy decisions for RBT operations. Copyright © 2013 Elsevier Ltd. All rights reserved.
Fecal /sup 13/C analysis for the detection and quantitation of intestinal malabsorption
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klein, P.D.; MacLean, W.C. Jr.; Watkins, J.B.
Use of /sup 14/CO/sub 2/ breath tests and fecal analyses for the detection and quantitation of intestinal malabsorption has been extensively documented in adult subjects. The use of radioisotopes has extended the range of breath test applications to include pediatric and geriatric subjects. Here we report a fecal /sup 13/C analysis that can be used in conjunction with /sup 14/CO/sub 2/ breath tests. Twenty-four-hour fecal samples were collected before and after the administration of a labeled substrate. Simultaneous cholyglycine /sup 13/CO/sub 2/ breath tests and fecal assays were performed in five children. One child with bacterial overgrowth had an abnormalmore » breath test and a normal fecal test. Of three children with ileal dysfunction, only one had an abnormal breath test, whereas the fecal test was abnormal in all three. Both the breath test and fecal test were abnormal for a child who had undergone an ileal resection. Both tests were normal for a child with ulcerative colitis.« less
42 CFR 84.88 - Breathing bag test.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Apparatus § 84.88 Breathing bag test. (a) Breathing bags will be tested in an air atmosphere saturated with... Institute upon request. (d) The air within the bag(s) shall not contain more than 100 parts per million of... 42 Public Health 1 2014-10-01 2014-10-01 false Breathing bag test. 84.88 Section 84.88 Public...
Scherman Rydhög, Jonas; Riisgaard de Blanck, Steen; Josipovic, Mirjana; Irming Jølck, Rasmus; Larsen, Klaus Richter; Clementsen, Paul; Lars Andersen, Thomas; Poulsen, Per Rugaard; Fredberg Persson, Gitte; Munck Af Rosenschold, Per
2017-04-01
The purpose of this study was to estimate the uncertainty in voluntary deep-inspiration breath-hold (DIBH) radiotherapy for locally advanced non-small cell lung cancer (NSCLC) patients. Perpendicular fluoroscopic movies were acquired in free breathing (FB) and DIBH during a course of visually guided DIBH radiotherapy of nine patients with NSCLC. Patients had liquid markers injected in mediastinal lymph nodes and primary tumours. Excursion, systematic- and random errors, and inter-breath-hold position uncertainty were investigated using an image based tracking algorithm. A mean reduction of 2-6mm in marker excursion in DIBH versus FB was seen in the anterior-posterior (AP), left-right (LR) and cranio-caudal (CC) directions. Lymph node motion during DIBH originated from cardiac motion. The systematic- (standard deviation (SD) of all the mean marker positions) and random errors (root-mean-square of the intra-BH SD) during DIBH were 0.5 and 0.3mm (AP), 0.5 and 0.3mm (LR), 0.8 and 0.4mm (CC), respectively. The mean inter-breath-hold shifts were -0.3mm (AP), -0.2mm (LR), and -0.2mm (CC). Intra- and inter-breath-hold uncertainty of tumours and lymph nodes were small in visually guided breath-hold radiotherapy of NSCLC. Target motion could be substantially reduced, but not eliminated, using visually guided DIBH. Copyright © 2017 Elsevier B.V. All rights reserved.
Clinical significance of the glucose breath test in patients with inflammatory bowel disease.
Lee, Ji Min; Lee, Kang-Moon; Chung, Yoon Yung; Lee, Yang Woon; Kim, Dae Bum; Sung, Hea Jung; Chung, Woo Chul; Paik, Chang-Nyol
2015-06-01
Small intestinal bacterial overgrowth which has recently been diagnosed with the glucose breath test is characterized by excessive colonic bacteria in the small bowel, and results in gastrointestinal symptoms that mimic symptoms of inflammatory bowel disease. This study aimed to estimate the positivity of the glucose breath test and investigate its clinical role in inflammatory bowel disease. Patients aged > 18 years with inflammatory bowel disease were enrolled. All patients completed symptom questionnaires. Fecal calprotectin level was measured to evaluate the disease activity. Thirty historical healthy controls were used to determine normal glucose breath test values. A total of 107 patients, 64 with ulcerative colitis and 43 with Crohn's disease, were included. Twenty-two patients (20.6%) were positive for the glucose breath test (30.2%, Crohn's disease; 14.1%, ulcerative colitis). Positive rate of the glucose breath test was significantly higher in patients with Crohn's disease than in healthy controls (30.2% vs 6.7%, P=0.014). Bloating, flatus, and satiety were higher in glucose breath test-positive patients than glucose breath test-negative patients (P=0.021, 0.014, and 0.049, respectively). The positivity was not correlated with the fecal calprotectin level. The positive rate of the glucose breath test was higher in patients with inflammatory bowel disease, especially Crohn's disease than in healthy controls; gastrointestinal symptoms of patients with inflammatory bowel disease were correlated with this positivity. Glucose breath test can be used to manage intestinal symptoms of patients with inflammatory bowel disease. © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
Laboratory testing of two prototype in-vehicle breath test devices
DOT National Transportation Integrated Search
1985-08-01
This report presents the results of laboratory testing of two recently developed prototype in-vehicle breath test devices. These devices are designed to prevent persons with alcohol on their breath from driving a car. The devices tested were the SOBE...
Houben, Els; De Preter, Vicky; Billen, Jaak; Van Ranst, Marc; Verbeke, Kristin
2015-01-01
The lactose hydrogen breath test is a commonly used, non-invasive method for the detection of lactose malabsorption and is based on an abnormal increase in breath hydrogen (H2) excretion after an oral dose of lactose. We use a combined 13C/H2 lactose breath test that measures breath 13CO2 as a measure of lactose digestion in addition to H2 and that has a better sensitivity and specificity than the standard test. The present retrospective study evaluated the results of 1051 13C/H2 lactose breath tests to assess the impact on the diagnostic accuracy of measuring breath CH4 in addition to H2 and 13CO2. Based on the 13C/H2 breath test, 314 patients were diagnosed with lactase deficiency, 138 with lactose malabsorption or small bowel bacterial overgrowth (SIBO), and 599 with normal lactose digestion. Additional measurement of CH4 further improved the accuracy of the test as 16% subjects with normal lactose digestion and no H2-excretion were found to excrete CH4. These subjects should have been classified as subjects with lactose malabsorption or SIBO. In conclusion, measuring CH4-concentrations has an added value to the 13C/H2 breath test to identify methanogenic subjects with lactose malabsorption or SIBO. PMID:26371034
Braden, B; Caspary, W F; Lembcke, B
1999-06-01
13C-urea breath tests have become clinical routine for the diagnosis of Helicobacter pylori infection and other isotope breath tests have been invented e.g. for gastric emptying or quantitative liver function testing. Recently, isotope-selective nondispersive infrared spectrometers (NDIRS) have been developed for the analysis of the 13CO2/12CO2-enrichment in breath. In this study, we prospectively tested the validity of a newly developed NDIRS in comparison to isotope ratio mass spectrometry (IRMS). 142 patients with dyspeptic symptoms were tested for Helicobacter pylori infection using the 13C-urea breath test. The isotope ratio analysis of the breath samples was performed in duplicate both using IRMS and NDIRS. The results of the baseline-corrected 13CO2-exhalation values between IRMS and NDIRS were in excellent agreement. The mean difference between both methods was 0.28 +/- 1.93 delta/1000. Evaluating the qualitative urea breath test results in reference to IRMS as the reference the NDIRS had a sensitivity of 97.8% and a specificity of 98.9%. The isotope-selective nondispersive infrared spectroscopy is going to become a reliable, but low-cost and easy-to-operate alternative to expensive isotope ratio mass spectrometry in the analysis of 13C-breath tests.
Pulmonary Function Testing in Children
... breathing test. About 15 minutes after taking the medicine, your child will repeat the breathing test. The results from ... the first test to find out if the medicine has improved your child’s breathing. Why shouldn’t I give my child ...
sup 14 C-urea breath test for the detection of Helicobacter pylori
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veldhuyzen van Zanten, S.J.; Tytgat, K.M.; Hollingsworth, J.
1990-04-01
The high urease activity of Helicobacter pylori can be used to detect this bacterium by noninvasive breath tests. We have developed a {sup 14}C-urea breath test which uses 5 microCi {sup 14}C with 50 mg nonradioactive urea. Breath samples are collected at baseline and every 30 min for 2 h. Our study compared the outcome of the breath test to the results of histology and culture of endoscopically obtained gastric biopsies in 84 patients. The breath test discriminated well between the 50 positive patients and the 34 patients negative for Helicobacter pylori: the calculated sensitivity was 100%, specificity 88%, positivemore » predictive value 93%, and negative predictive value 100%. Treatment with bismuth subsalicylate and/or ampicillin resulted in lower counts of exhaled {sup 14}CO{sub 2} which correlated with histological improvement in gastritis. The {sup 14}C-urea breath test is a better gold standard for the detection of Helicobacter pylori than histology and/or culture.« less
Tisch, Ulrike; Haick, Hossam
2014-06-01
Profiling the body chemistry by means of volatile organic compounds (VOCs) in the breath opens exciting new avenues in medical diagnostics. Gas sensors could provide ideal platforms for realizing portable, hand-held breath testing devices in the near future. This review summarizes the latest developments and applications in the field of chemical sensors for diagnostic breath testing that were presented at the Breath Analysis Summit 2013 in Wallerfangen, Germany. Considerable progress has been made towards clinically applicable breath testing devices, especially by utilizing chemo-sensitive nanomaterials. Examples of several specialized breath testing applications are presented that are either based on stand-alone nanomaterial-based sensors being highly sensitive and specific to individual breath compounds over others, or on combinations of several highly specific sensors, or on experimental nanomaterial-based sensors arrays. Other interesting approaches include the adaption of a commercially available MOx-based sensor array to indirect breath testing applications, using a sample pre-concentration method, and the development of compact integrated GC-sensor systems. The recent trend towards device integration has led to the development of fully integrated prototypes of point-of-care devices. We describe and compare the performance of several prototypes that are based on different sensing technologies and evaluate their potential as low-cost and readily available next-generation medical devices.
Sensing the effects of mouth breathing by using 3-tesla MRI
NASA Astrophysics Data System (ADS)
Park, Chan-A.; Kang, Chang-Ki
2017-06-01
We investigated the effects of mouth breathing and typical nasal breathing on brain function by using blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging (fMRI). The study had two parts: the first test was a simple contrast between mouth and nasal breathing, and the second test involved combined breathing modes, e.g., mouth inspiration and nasal expiration. Eleven healthy participants performed the combined breathing task while undergoing 3T fMRI. In the group-level analysis, contrast images acquired by using an individual participantlevel analysis were processed using the one-sample t test. We also conducted a region-of-interest analysis comparing signal intensity changes between the breathing modes; the region was selected using an automated anatomical labeling map. The results demonstrated that the BOLD signal in the hippocampus and brainstem was significantly decreased in mouth breathing relative to nasal breathing. On the other hand, both the precentral and postcentral gyri showed activation that was more significant in mouth breathing compared to nasal breathing. This study suggests that the BOLD activity patterns between mouth and nasal breathing may be induced differently, especially in the hippocampus, which could provide clues to explain the effects on brain cognitive function due to mouth breathing.
[*C]octanoic acid breath test to measure gastric emptying rate of solids.
Maes, B D; Ghoos, Y F; Rutgeerts, P J; Hiele, M I; Geypens, B; Vantrappen, G
1994-12-01
We have developed a breath test to measure solid gastric emptying using a standardized scrambled egg test meal (250 kcal) labeled with [14C]octanoic acid or [13C]octanoic acid. In vitro incubation studies showed that octanoic acid is a reliable marker of the solid phase. The breath test was validated in 36 subjects by simultaneous radioscintigraphic and breath test measurements. Nine healthy volunteers were studied after intravenous administration of 200 mg erythromycin and peroral administration of 30 mg propantheline, respectively. Erythromycin significantly enhanced gastric emptying, while propantheline significantly reduced gastric emptying rates. We conclude that the [*C]octanoic breath test is a promising and reliable test for measuring the gastric emptying rate of solids.
Ahmadi, Zohre; Torkzahrani, Shahnaz; Roosta, Firouze; Shakeri, Nezhat; Mhmoodi, Zohre
2017-01-01
Introduction: One of the important tasks in managing labor is the protection of perineum. An important variable affecting this outcome is maternal pushing during the second stage of labor. This study was done to investigate the effect of breathing technique on perineal damage extention in laboring Iranian women. Materials and Methods: This randomized clinical trial was performed on 166 nulliparous pregnant women who had reached full-term pregnancy, had low risk pregnancy, and were candidates for vaginal delivery in two following groups: using breathing techniques (case group) and valsalva maneuver (control group). In the control group, pushing was done with holding the breath. In the case group, the women were asked to take 2 deep abdominal breaths at the onset of pain, then take another deep breath, and push 4–5 seconds with the open mouth while controlling exhalation. From the crowning stage onward, the women were directed to control their pushing, and do the blowing technique. Results: According to the results, intact perineum was more observed in the case group (P = 0.002). Posterior tears (Grade 1, 2, and 3) was considerably higher in the control group (P = 0.003). Anterior tears (labias) and episiotomy were not significantly different in the two groups. Conclusions: It was concluded that breathing technique of blowing can be a good alternative to Valsalva maneuver in order to reduce perineal damage in laboring women. PMID:28382061
Israeli, Eran; Ilan, Yaron; Meir, Shimon Bar; Buenavida, Claudia; Goldin, Eran
2003-08-01
The aim of this study is to determine the accuracy of a novel laptop sized 13C-Urea breath test analyzer that continuously measures expired breath and to use its advantages to decrease testing time. One hundred and eighty-six subjects (mean age of 47.8 years) were tested simultaneously by the BreathID system (Oridion, Israel), and by the traditional IRMS. BreathID continuously measured the expired breath for a ratio of 13CO(2):12CO(2.) This value was expressed as delta over baseline (DOB) and displayed graphically on a screen in real time. One hundred and one subjects were positive and 85 were negative for H. pylori by isotope ratio mass spectrometry (IRMS). The correlation for the BreathID system at 30 minutes was 100% for positive cases and 98% for negative cases. Analysis of the continuous curves generated by the BreathID for all patients permitted definition of different DOB thresholds for a positive or negative result at shorter time intervals. Thus, after 6 minutes a conclusive test result could be obtained for 64% of subjects, and after 10 minutes for 92% of subjects. The 13C-Urea breath test utilizing the technology of molecular correlation spectrometry is an accurate method for determining infection by H. pylori. The advantage of continuous measurements can shorten testing time without compromising accuracy.
News from the Breath Analysis Summit 2011.
Corradi, Massimo; Mutti, Antonio
2012-06-01
This special section highlights some of the important work presented at the Breath Analysis Summit 2011, which was held in Parma (Italy) from 11 to 14 September 2011. The meeting, which was jointly organized by the International Association for Breath Research and the University of Parma, was attended by more than 250 delegates from 33 countries, and offered 34 invited lectures and 64 unsolicited scientific contributions. The summit was organized to provide a forum to scientists, engineers and clinicians to present their latest findings and to meet industry executives and entrepreneurs to discuss key trends, future directions and technologies available for breath analysis. A major focus was on nitric oxide, exhaled breath condensate, electronic nose, mass spectrometry and newer sensor technologies. Medical applications ranged from asthma and other respiratory diseases to gastrointestinal disease, occupational diseases, critical care and cancer. Most people identify breath tests with breathalysers used by police to estimate ethanol concentration in blood. However, breath testing has far more sophisticated applications. Breath analysis is rapidly evolving as a new frontier in medical testing for disease states in the lung and beyond. Every individual has a breath fingerprint-or 'breathprint'-that can provide useful information about his or her state of health. This breathprint comprises the many thousands of molecules that are expelled with each breath we exhale. Breath research in the past few years has uncovered the scientific and molecular basis for such clinical observations. Relying on mass spectrometry, we have been able to identify many such unique substances in exhaled breath, including gases, such as nitric oxide (NO) and carbon monoxide (CO), and a wide array of volatile organic compounds. Exhaled breath also carries aerosolized droplets that can be collected as an exhaled breath condensate that contains endogenously produced non-volatile compounds. Breath analysis is now used to diagnose and monitor asthma, check for transplant organ rejection, detect lung cancer and test for Helicobacter pyloriinfection-and the list is growing. A major milestone in the scientific study of breath was marked in the 1970s when Linus Pauling demonstrated that there is more to exhaled breath than the classic gases of nitrogen, oxygen, carbon dioxide and water vapour-a lot more. Based on the gas-liquid partition chromatography analysis, Pauling reported the presence of 250 substances in exhaled breath. We now have the technology to test for any and all of these components. The field of breath analysis has made considerable advances in the 21st century and the utility of breath analysis in health care is advancing quickly. The science is rapidly expanding, the technology is improving and several new applications have been developed or are under commercial development. Breath analysis may rely on both direct (on line) and indirect (off line) reading methods: in the on-line method, breath analysis is immediately available, whereas the use of indirect methods generally involves collecting and trapping the breath sample and subsequently transferring it to an analytical instrument for analysis. Various kinds of breath samples have been used in biological monitoring, including mixed expired air and end expired air: end exhaled air represents the alveolar air concentration and mixed exhaled air represents the gas mixture coming from the dead space of the bronchial tree and the alveolar gas-exchange space. Exhaled breath analysis is an area where the modern day advances in technology and engineering meet the ever expanding need in medicine for more sensitive, specific and non-invasive tests which makes this area a major front in the interface between medicine and engineering. A major breakthrough over the past decade has been the increase in breath-based tests approved by the US Food and Drug Administration (FDA). Devices measuring common breath gases (oxygen, nitrogen, water vapour and CO(2)) in patient respiratory monitoring have served as a platform for technological growth in clinical breath-testing applications. A few exhaled breath tests have demonstrated clinical utility and are in widespread use, and several FDA-approved devices are available. These widely used exhaled breath tests include detection of blood alcohol concentration and exhaled CO(2). Other clinical applications of exhaled breath analysis include testing for H. pylori infection, lactose intolerance, heart transplant rejection and, more recently, monitoring of airway inflammation by means of exhaled NO. Examination of exhaled breath has the potential to change the existing routine approaches in human medicine. The rapidly developing new analytical and computer technologies along with novel, unorthodox ideas are prerequisites for future advances in this field. Scientists who participated in the Breath Analysis Summit 2011 were invited to submit a full length paper to the Journal of Breath Research and this issue includes eight articles which describe the different applications of breath analysis. We thank all the authors for their valuable contribution and we trust that this collection will provide useful information and an update to this rapidly evolving field, giving an example of integration among scientists who address the same topic-breath analysis-from different and complementary perspectives, from basic to clinical research.
Lochocka, Klaudia; Bajerska, Joanna; Glapa, Aleksandra; Fidler-Witon, Ewa; Nowak, Jan K; Szczapa, Tomasz; Grebowiec, Philip; Lisowska, Aleksandra; Walkowiak, Jaroslaw
2015-07-30
Green tea is known worldwide for its beneficial effects on human health. However, objective data evaluating this influence in humans is scarce. The aim of the study was to assess the impact of green tea extract (GTE) on starch digestion and absorption. The study comprised of 28 healthy volunteers, aged 19 to 28 years. In all subjects, a starch (13)C breath test was performed twice. Subjects randomly ingested naturally (13)C-abundant cornflakes during the GTE test (GTE 4 g) or placebo test. The cumulative percentage dose recovery (CPDR) was significantly lower for the GTE test than for the placebo test (median [interquartile range]: 11.4% [5.5-15.5] vs. 16.1% [12.7-19.5]; p = 0.003). Likewise, CPDR expressed per hour was considerably lower in each point of the measurement. In conclusion, a single dose of green tea extract taken with a test meal decreases starch digestion and absorption.
Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof
2015-04-01
Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.
Eves, Neil D; Petersen, Stewart R; Jones, Richard L
2003-10-01
The self-contained breathing apparatus (SCBA) used by firefighters, and other working in dangerous environments, adds an external resistance to expiration, which increases expiratory work during heavy exercise. Compressed air is typically used with the SCBA and we hypothesized that changing the inspired oxygen concentration and/or gas density with helium would reduce the external expiratory resistance. On separate days, 15 men completed four 30-min bouts of treadmill exercise dressed in protective clothing and breathing the test gases through the SCBA. Four different gas mixtures were assigned in random order: [compressed air (NOX: 21% O2, 79% N2), hyperoxia (HOX: 40% O2, 60% N2), normoxic-helium (HE-OX: 21% O2, 79% He), and helium-hyperoxia (HE-HOX: 40% O2, 60% He)]. Compared with NOX, the two helium mixtures (but not HOX), decreased the external breathing resistance and all three gas mixtures decreased the peak expired mask pressure and the ventilatory mass moved. Both hyperoxic mixtures decreased blood lactate and the rating of perceived exertion was decreased at 30 min with HE-HOX. These results demonstrate that the helium-based gas mixtures, and to a lesser extent HOX, reduce the expiratory work associated with the SCBA during strenuous exercise.
Prediction of heart transplant rejection with a breath test for markers of oxidative stress.
Phillips, Michael; Boehmer, John P; Cataneo, Renee N; Cheema, Taseer; Eisen, Howard J; Fallon, John T; Fisher, Peter E; Gass, Alan; Greenberg, Joel; Kobashigawa, Jon; Mancini, Donna; Rayburn, Barry; Zucker, Mark J
2004-12-15
The Heart Allograft Rejection: Detection with Breath Alkanes in Low Levels study evaluated a breath test for oxidative stress in heart transplant recipients, and we report here a mathematical model predicting the probability of grade 3 rejection. The breath test divided the heart transplant recipients into 3 groups: positive for grade 3 rejection, negative for grade 3 rejection, and intermediate. The test was 100% sensitive for grade 3 heart transplant rejection when the p value was >/=0.98, and 100% specific when the p value was =0.058; in the intermediate group, the breath test determined the probability of grade 3 rejection and the predictive value of the result.
Co-occurrence of carbohydrate malabsorption and primary epiploic appendagitis
Schnedl, Wolfgang J; Kalmar, Peter; Mangge, Harald; Krause, Robert; Wallner-Liebmann, Sandra J
2015-01-01
Unspecific abdominal complaints including bloating and irregular bowel movements may be caused by carbohydrate malabsorption syndromes, e.g., lactose and fructose malabsorption. These symptoms were investigated with hydrogen (H2) breath tests and correlated to carbohydrate malabsorption. During performing these H2-breath tests the patient presented with an acute, localized, non-migratory pain in the left lower abdominal quadrant. Primary epiploic appendagitis is a rare cause of abdominal acute or subacute complaints and diagnosis of primary epiploic appendagitis (PEA) is made when computed tomography reveals a characteristic lesion. We report on a patient with co-occurrence of lactose and fructose malabsorption, which was treated successfully with a diet free of culprit carbohydrates, with PEA recovering without medication or surgical treatment within few days. Since the abdominal unspecific symptoms had been present for months, they appeared not to be correlated to the acute localized abdominal pain, therefore we speculate on a random co-occurrence of combined carbohydrate malabsorption and PEA. PMID:26401090
46 CFR 197.450 - Breathing gas tests.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Breathing gas tests. 197.450 Section 197.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE OCCUPATIONAL SAFETY AND HEALTH STANDARDS GENERAL PROVISIONS Commercial Diving Operations Periodic Tests and Inspections of Diving Equipment § 197.450 Breathing gas tests. The diving...
Thompson, Kate R; Bardell, David
2016-03-01
To compare the effect of two different intraoperative end-tidal carbon dioxide tensions on apnoeic duration in the recovery period in horses. Prospective randomized clinical study. Eighteen healthy client-owned adult horses (ASA I-II) admitted for elective surgery. Horses were of a median body mass of 595 (238-706) kg and a mean age of 9 ± 5 years. A standardized anaesthetic protocol was used. Horses were positioned in dorsal recumbency and randomly allocated to one of two groups. Controlled mechanical ventilation (CMV) was adjusted to maintain the end-tidal carbon dioxide tension (Pe'CO2 ) at 40 ± 5 mmHg (5.3 ± 0.7 kPa) (group 40) or 60 ± 5 mmHg (8.0 ± 0.7 kPa) (group 60). Arterial blood gas analysis was performed at the start of the anaesthetic period (T0), at one point during the anaesthetic (T1), immediately prior to disconnection from the breathing system (T2) and at the first spontaneous breath in the recovery box (T3). The time from disconnection from the breathing system to return to spontaneous ventilation (RSV) was recorded. Data were analysed using a two sample t-test or the Mann-Whitney U-test and significance assigned when p < 0.05. Horses in group 60 resumed spontaneous breathing significantly earlier than those in group 40, [52 (14-151) and 210 (103-542) seconds, respectively] (p < 0.001). Arterial oxygen tension (PaO2 ), pH, base excess (BE) and plasma bicarbonate (HCO3-) were not different between the groups at RSV, however, PaO2 was significantly lower in group 60 during (T1) and at the end of anaesthesia (T2). Aiming to maintain intra-operative Pe'CO2 at 60 ± 5 mmHg (8.0 ± 0.7 kPa) in mechanically ventilated horses resulted in more rapid RSV compared with when Pe'CO2 was maintained at 40 ± 5 mmHg (5.3 ± 0.7 kPa). © 2015 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.
Westerdahl, Elisabeth; Urell, Charlotte; Jonsson, Marcus; Bryngelsson, Ing-Liss; Hedenström, Hans; Emtner, Margareta
2014-01-01
Postoperative breathing exercises are recommended to cardiac surgery patients. Instructions concerning how long patients should continue exercises after discharge vary, and the significance of treatment needs to be determined. Our aim was to assess the effects of home-based deep breathing exercises performed with a positive expiratory pressure device for 2 months following cardiac surgery. The study design was a prospective, single-blinded, parallel-group, randomized trial. Patients performing breathing exercises 2 months after cardiac surgery (n = 159) were compared with a control group (n = 154) performing no breathing exercises after discharge. The intervention consisted of 30 slow deep breaths performed with a positive expiratory pressure device (10-15 cm H2O), 5 times a day, during the first 2 months after surgery. The outcomes were lung function measurements, oxygen saturation, thoracic excursion mobility, subjective perception of breathing and pain, patient-perceived quality of recovery (40-Item Quality of Recovery score), health-related quality of life (36-Item Short Form Health Survey), and self-reported respiratory tract infection/pneumonia and antibiotic treatment. Two months postoperatively, the patients had significantly reduced lung function, with a mean decrease in forced expiratory volume in 1 second to 93 ± 12% (P< .001) of preoperative values. Oxygenation had returned to preoperative values, and 5 of 8 aspects in the 36-Item Short Form Health Survey were improved compared with preoperative values (P< .01). There were no significant differences between the groups in any of the measured outcomes. No significant differences in lung function, subjective perceptions, or quality of life were found between patients performing home-based deep breathing exercises and control patients 2 months after cardiac surgery.
(13)C-Breath testing in animals: theory, applications, and future directions.
McCue, Marshall D; Welch, Kenneth C
2016-04-01
The carbon isotope values in the exhaled breath of an animal mirror the carbon isotope values of the metabolic fuels being oxidized. The measurement of stable carbon isotopes in carbon dioxide is called (13)C-breath testing and offers a minimally invasive method to study substrate oxidation in vivo. (13)C-breath testing has been broadly used to study human exercise, nutrition, and pathologies since the 1970s. Owing to reduced use of radioactive isotopes and the increased convenience and affordability of (13)C-analyzers, the past decade has witnessed a sharp increase in the use of breath testing throughout comparative physiology--especially to answer questions about how and when animals oxidize particular nutrients. Here, we review the practical aspects of (13)C-breath testing and identify the strengths and weaknesses of different methodological approaches including the use of natural abundance versus artificially-enriched (13)C tracers. We critically compare the information that can be obtained using different experimental protocols such as diet-switching versus fuel-switching. We also discuss several factors that should be considered when designing breath testing experiments including extrinsic versus intrinsic (13)C-labelling and different approaches to model nutrient oxidation. We use case studies to highlight the myriad applications of (13)C-breath testing in basic and clinical human studies as well as comparative studies of fuel use, energetics, and carbon turnover in multiple vertebrate and invertebrate groups. Lastly, we call for increased and rigorous use of (13)C-breath testing to explore a variety of new research areas and potentially answer long standing questions related to thermobiology, locomotion, and nutrition.
Data Mining Techniques Applied to Hydrogen Lactose Breath Test.
Rubio-Escudero, Cristina; Valverde-Fernández, Justo; Nepomuceno-Chamorro, Isabel; Pontes-Balanza, Beatriz; Hernández-Mendoza, Yoedusvany; Rodríguez-Herrera, Alfonso
2017-01-01
Analyze a set of data of hydrogen breath tests by use of data mining tools. Identify new patterns of H2 production. Hydrogen breath tests data sets as well as k-means clustering as the data mining technique to a dataset of 2571 patients. Six different patterns have been extracted upon analysis of the hydrogen breath test data. We have also shown the relevance of each of the samples taken throughout the test. Analysis of the hydrogen breath test data sets using data mining techniques has identified new patterns of hydrogen generation upon lactose absorption. We can see the potential of application of data mining techniques to clinical data sets. These results offer promising data for future research on the relations between gut microbiota produced hydrogen and its link to clinical symptoms.
Teschler, Sebastian; Jarosch, Inga; Christle, Jeffrey W; Hitzl, Wolfgang; Kenn, Klaus
2016-01-01
The two-minute walk test (2MWT) is less well validated than the well-known six-minute walk test (6MWT) as a field walking test in patients with chronic obstructive pulmonary disease (COPD). The primary objective of this study was to compare the accuracy of the 2MWT to the 6MWT in detecting exercise-induced oxygen desaturation in patients with severe COPD. Twenty-six patients with COPD (age: 61 ± 10 years, forced expired volume in one second: 37 ± 10%) that were normoxemic at rest performed a 2MWT and a 6MWT under normal ambient conditions on two consecutive days in random order. Oxygen saturation, total walking distance, heart rate, breathing frequency, dyspnea, and leg fatigue were evaluated. Average walking distances were 150 m (95% confidence interval (95% CI): 134–165 m) and 397 m (95% CI: 347–447 m) for the 2MWT and 6MWT, respectively (r = 0.80, p < 0.0001). The difference in minimum oxygen saturation during the 2MWT (83%, 95% CI: 81–86%) and 6MWT (mean 82%, 95% CI: 80–84%) was not statistically different and the data strongly correlated between the groups (r = 0.81, p < 0.0001). Other measurements from the 6MWT, including heart rate, breathing rate, and levels of perceived exertion were also comparable in 2MWT. The 2MWT showed comparable validity in detecting exercise-induced oxygen desaturation in patients with severe COPD compared to the 6MWT. PMID:26961775
Gloeckl, Rainer; Teschler, Sebastian; Jarosch, Inga; Christle, Jeffrey W; Hitzl, Wolfgang; Kenn, Klaus
2016-03-08
The two-minute walk test (2MWT) is less well validated than the well-known six-minute walk test (6MWT) as a field walking test in patients with chronic obstructive pulmonary disease (COPD). The primary objective of this study was to compare the accuracy of the 2MWT to the 6MWT in detecting exercise-induced oxygen desaturation in patients with severe COPD. Twenty-six patients with COPD (age: 61 ± 10 years, forced expired volume in one second: 37 ± 10%) that were normoxemic at rest performed a 2MWT and a 6MWT under normal ambient conditions on two consecutive days in random order. Oxygen saturation, total walking distance, heart rate, breathing frequency, dyspnea, and leg fatigue were evaluated. Average walking distances were 150 m (95% confidence interval (95% CI): 134-165 m) and 397 m (95% CI: 347-447 m) for the 2MWT and 6MWT, respectively (r = 0.80, p < 0.0001). The difference in minimum oxygen saturation during the 2MWT (83%, 95% CI: 81-86%) and 6MWT (mean 82%, 95% CI: 80-84%) was not statistically different and the data strongly correlated between the groups (r = 0.81, p < 0.0001). Other measurements from the 6MWT, including heart rate, breathing rate, and levels of perceived exertion were also comparable in 2MWT. The 2MWT showed comparable validity in detecting exercise-induced oxygen desaturation in patients with severe COPD compared to the 6MWT. © The Author(s) 2016.
Yu, Haitao; Dhingra, Rishi R; Dick, Thomas E; Galán, Roberto F
2017-01-01
Neural activity generally displays irregular firing patterns even in circuits with apparently regular outputs, such as motor pattern generators, in which the output frequency fluctuates randomly around a mean value. This "circuit noise" is inherited from the random firing of single neurons, which emerges from stochastic ion channel gating (channel noise), spontaneous neurotransmitter release, and its diffusion and binding to synaptic receptors. Here we demonstrate how to expand conductance-based network models that are originally deterministic to include realistic, physiological noise, focusing on stochastic ion channel gating. We illustrate this procedure with a well-established conductance-based model of the respiratory pattern generator, which allows us to investigate how channel noise affects neural dynamics at the circuit level and, in particular, to understand the relationship between the respiratory pattern and its breath-to-breath variability. We show that as the channel number increases, the duration of inspiration and expiration varies, and so does the coefficient of variation of the breath-to-breath interval, which attains a minimum when the mean duration of expiration slightly exceeds that of inspiration. For small channel numbers, the variability of the expiratory phase dominates over that of the inspiratory phase, and vice versa for large channel numbers. Among the four different cell types in the respiratory pattern generator, pacemaker cells exhibit the highest sensitivity to channel noise. The model shows that suppressing input from the pons leads to longer inspiratory phases, a reduction in breathing frequency, and larger breath-to-breath variability, whereas enhanced input from the raphe nucleus increases breathing frequency without changing its pattern. A major source of noise in neuronal circuits is the "flickering" of ion currents passing through the neurons' membranes (channel noise), which cannot be suppressed experimentally. Computational simulations are therefore the best way to investigate the effects of this physiological noise by manipulating its level at will. We investigate the role of noise in the respiratory pattern generator and show that endogenous, breath-to-breath variability is tightly linked to the respiratory pattern. Copyright © 2017 the American Physiological Society.
Design and Validation of a Breathing Detection System for Scuba Divers.
Altepe, Corentin; Egi, S Murat; Ozyigit, Tamer; Sinoplu, D Ruzgar; Marroni, Alessandro; Pierleoni, Paola
2017-06-09
Drowning is the major cause of death in self-contained underwater breathing apparatus (SCUBA) diving. This study proposes an embedded system with a live and light-weight algorithm which detects the breathing of divers through the analysis of the intermediate pressure (IP) signal of the SCUBA regulator. A system composed mainly of two pressure sensors and a low-power microcontroller was designed and programmed to record the pressure sensors signals and provide alarms in absence of breathing. An algorithm was developed to analyze the signals and identify inhalation events of the diver. A waterproof case was built to accommodate the system and was tested up to a depth of 25 m in a pressure chamber. To validate the system in the real environment, a series of dives with two different types of workload requiring different ranges of breathing frequencies were planned. Eight professional SCUBA divers volunteered to dive with the system to collect their IP data in order to participate to validation trials. The subjects underwent two dives, each of 52 min on average and a maximum depth of 7 m. The algorithm was optimized for the collected dataset and proved a sensitivity of inhalation detection of 97.5% and a total number of 275 false positives (FP) over a total recording time of 13.9 h. The detection algorithm presents a maximum delay of 5.2 s and requires only 800 bytes of random-access memory (RAM). The results were compared against the analysis of video records of the dives by two blinded observers and proved a sensitivity of 97.6% on the data set. The design includes a buzzer to provide audible alarms to accompanying dive buddies which will be triggered in case of degraded health conditions such as near drowning (absence of breathing), hyperventilation (breathing frequency too high) and skip-breathing (breathing frequency too low) measured by the improper breathing frequency. The system also measures the IP at rest before the dive and indicates with flashing light-emitting diodes and audible alarm the regulator malfunctions due to high or low IP that may cause fatal accidents during the dive by preventing natural breathing. It is also planned to relay the alarm signal to underwater and surface rescue authorities by means of acoustic communication.
Development and Evaluation of Algorithms for Breath Alcohol Screening.
Ljungblad, Jonas; Hök, Bertil; Ekström, Mikael
2016-04-01
Breath alcohol screening is important for traffic safety, access control and other areas of health promotion. A family of sensor devices useful for these purposes is being developed and evaluated. This paper is focusing on algorithms for the determination of breath alcohol concentration in diluted breath samples using carbon dioxide to compensate for the dilution. The examined algorithms make use of signal averaging, weighting and personalization to reduce estimation errors. Evaluation has been performed by using data from a previously conducted human study. It is concluded that these features in combination will significantly reduce the random error compared to the signal averaging algorithm taken alone.
Coelho, Luiz Gonzaga Vaz; Silva, Arilto Eleutério da; Coelho, Maria Clara de Freitas; Penna, Francisco Guilherme Cancela e; Ferreira, Rafael Otto Antunes; Santa-Cecilia, Elisa Viana
2011-01-01
The standard doses of (13)C-urea in (13)C-urea breath test is 75 mg. To assess the diagnostic accuracy of (13)C-urea breath test containing 25 mg of (13)C-urea comparing with the standard doses of 75 mg in the diagnosis of Helicobacter pylori infection. Two hundred seventy adult patients (96 males, 174 females, median age 41 years) performed the standard (13)C-urea breath test (75 mg (13)C-urea) and repeated the (13)C-urea breath test using only 25 mg of (13)C-urea within a 2 week interval. The test was performed using an infrared isotope analyzer. Patients were considered positive if delta over baseline was >4.0‰ at the gold standard test. One hundred sixty-one (59.6%) patients were H. pylori negative and 109 (40.4%) were positive by the gold standard test. Using receiver operating characteristic analysis we established a cut-off value of 3.4% as the best value of 25 mg (13)C-urea breath test to discriminate positive and negative patients, considering the H. pylori prevalence (95% CI: 23.9-37.3) at our setting. Therefore, we obtained to 25 mg (13)C-urea breath test a diagnostic accuracy of 92.9% (95% CI: 88.1-97.9), sensitivity 83.5% (95% CI: 75.4-89.3), specificity 99.4% (95% CI: 96.6-99.9), positive predictive value 98.3% (95% CI: 92.4-99.4), and negative predictive value 93.0% (95% CI: 88.6-96.1). Low-dose (13)C-urea breath test (25 mg (13)C-urea) does not reach accuracy sufficient to be recommended in clinical setting where a 30% prevalence of H. pylori infection is observed. Further studies should be done to determine the diagnostic accuracy of low doses of (13)C-urea in the urea breath test.
A metabolic simulator for unmanned testing of breathing apparatuses in hyperbaric conditions.
Frånberg, Oskar; Loncar, Mario; Larsson, Åke; Ornhagen, Hans; Gennser, Mikael
2014-11-01
A major part of testing of rebreather apparatuses for underwater diving focuses on the oxygen dosage system. A metabolic simulator for testing breathing apparatuses was built and evaluated. Oxygen consumption was achieved through catalytic combustion of propene. With an admixture of carbon dioxide in the propene fuel, the system allowed the respiratory exchange ratio to be set freely within human variability and also made it possible to increase test pressures above the condensation pressure of propene. The system was tested by breathing ambient air in a pressure chamber with oxygen uptake (Vo₂) ranging from 1-4 L · min(-1), tidal volume (VT) from 1-3 L, breathing frequency (f) of 20 and 25 breaths/min, and chamber pressures from 100 to 670 kPa. The measured end-tidal oxygen concentration (Fo₂) was compared to calculated end-tidal Fo₂. The largest average difference in end-tidal Fo₂during atmospheric pressure conditions was 0.63%-points with a 0.28%-point average difference during the whole test. During hyperbaric conditions with pressures ranging from 100 to 670 kPa, the largest average difference in Fo₂was 1.68%-points seen during compression from 100 kPa to 400 kPa and the average difference in Fo₂during the whole test was 0.29%-points. In combination with a breathing simulator simulating tidal breathing, the system can be used for dynamic continuous testing of breathing equipment with changes in VT, f, Vo2, and pressure.
49 CFR 40.267 - What problems always cause an alcohol test to be cancelled?
Code of Federal Regulations, 2012 CFR
2012-10-01
... breath tube ASD). (4) The breath tube ASD is tested with an analyzer which has not been pre-calibrated... the case of a screening test conducted on a saliva ASD or a breath tube ASD: (1) The STT or BAT reads... § 40.245(a)(8) for the saliva ASD and § 40.245(b)(8) for the breath tube ASD). (2) The saliva ASD does...
49 CFR 40.267 - What problems always cause an alcohol test to be cancelled?
Code of Federal Regulations, 2013 CFR
2013-10-01
... breath tube ASD). (4) The breath tube ASD is tested with an analyzer which has not been pre-calibrated... the case of a screening test conducted on a saliva ASD or a breath tube ASD: (1) The STT or BAT reads... § 40.245(a)(8) for the saliva ASD and § 40.245(b)(8) for the breath tube ASD). (2) The saliva ASD does...
49 CFR 40.267 - What problems always cause an alcohol test to be cancelled?
Code of Federal Regulations, 2014 CFR
2014-10-01
... breath tube ASD). (4) The breath tube ASD is tested with an analyzer which has not been pre-calibrated... the case of a screening test conducted on a saliva ASD or a breath tube ASD: (1) The STT or BAT reads... § 40.245(a)(8) for the saliva ASD and § 40.245(b)(8) for the breath tube ASD). (2) The saliva ASD does...
Operation and testing of Mark 10 Mod 3 underwater breathing apparatus
NASA Technical Reports Server (NTRS)
Milwee, W. I., Jr.
1972-01-01
Performance tests on a closed circuit, mixed gas underwater breathing apparatus are reported. The equipment is designed to provide a minimum diving duration of four hours at 1500 ft below sea surface; it senses oxygen partial pressure in the breathing gas mix and controls oxygen content of the breathing gas within narrow limits about a preset value. The breathing circuit subsystem provides respirable gas to the diver and removes carbon dioxide and moisture from the expired gas. Test results indicate undesirable variations in oxygen partial pressure with oxygen addition and insufficient carbon dioxide absorption.
Mols, G; von Ungern-Sternberg, B; Rohr, E; Haberthür, C; Geiger, K; Guttmann, J
2000-06-01
To assess respiratory comfort and associated breathing pattern during volume assist (VA) as a component of proportional assist ventilation and during pressure support ventilation (PSV). Prospective, double-blind, interventional study. Laboratory. A total of 15 healthy volunteers (11 females, 4 males) aged 21-31 yrs. Decreased respiratory system compliance was simulated by banding of the thorax and abdomen. Volunteers breathed via a mouthpiece with VA and PSV each applied at two levels (VA, 8 cm H2O/L and 12 cm H2O/L; PSV, 10 cm H2O and 15 cm H2O) using a positive end-expiratory pressure of 5 cm H2O throughout. The study was subdivided into two parts. In Part 1, volunteers breathed three times with each of the four settings for 2 mins in random order. In Part 2, the first breath effects of multiple, randomly applied mode, and level shifts were studied. In Part 1, the volunteers were asked to estimate respiratory comfort in comparison with normal breathing using a visual analog scale. In Part 2, they were asked to estimate the change of respiratory comfort as increased, decreased, or unchanged immediately after a mode shift. Concomitantly, the respiratory pattern (change) was characterized with continuously measured tidal volume, respiratory rate, pressure, and gas flow. Respiratory comfort during VA was higher than during PSV. The higher support level was less important during VA but had a major negative influence on comfort during PSV. Both modes differed with respect to the associated breathing pattern. Variability of breathing was higher during VA than during PSV (Part 1). Changes in respiratory variables were associated with changes in respiratory comfort (Part 2). For volunteers breathing with artificially reduced respiratory system compliance, respiratory comfort is higher with VA than with PSV. This is probably caused by a better adaptation of the ventilatory support to the volunteer's need with VA.
10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...
10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...
10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...
10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...
10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...
Johnson, Mark B; Clapp, John D
2011-01-01
Given that most effective alcohol harm-reduction laws specify the blood alcohol concentration (BAC) that constitutes illegal behavior (e.g., the .08% breath alcohol concentration legal limit), interventions that allow drinkers to accurately estimate their BACs, and thus better assess their risk, have potential importance to long-term driving-under-the-influence prevention efforts. This study describes a field experiment designed to test the impact on drinking of providing "Know Your Limit" (KYL) BAC estimation cards to individuals in a natural drinking environment. We randomly sampled 1,215 U.S. residents as they entered Mexico for a night of drinking, interviewed them, and randomly assigned them to one of six experimental conditions. Participants were reinterviewed and breath-tested when they returned to the United States. The experimental conditions included providing generic warnings about drinking and driving, giving out gender-specific BAC calculator cards (KYL cards), and providing incentives to moderate their drinking. Cueing participants about the risks of drunk driving resulted in significantly lower BACs (relative to control) for participants who indicated that they would drive home. Providing KYL matrixes did not reduce BACs, and, in fact, some evidence suggests that KYL cards undermined the effect of the warning. KYL information does not appear to be an effective tool for reducing drinking and driving. Implications for prevention and future research are discussed.
Variability in the blood/breath alcohol ratio and implications for evidentiary purposes.
Jaffe, Dena H; Siman-Tov, Maya; Gopher, Asher; Peleg, Kobi
2013-09-01
The breath analyzer is an indispensable tool for identifying alcohol levels among drivers. While numerous studies have shown high correlations between blood and breath alcohol concentrations, most are limited by the study design. This study seeks to assess this relationship by minimizing potential measurement bias, document time from alcohol consumption to testing, and adjusting for potential confounders. A blinded study was performed using conditions closely resembling those in the field. The Draeger 7110 MKIII IL breath analyzer was used to assess breath alcohol concentrations (BrAC). Participants were 61 healthy volunteers aged 21-37 years with body mass index ≤30 and no history of alcoholism. A total of 242 valid blood/breath tests were performed in four test sets. The study results showed a high correlation coefficient between BrAC and blood alcohol concentration (BAC) levels (r = 0.983) with high sensitivity (97%) and specificity (93%). This strong association between the breath analyzer and BAC persisted even after adjustment for various stages of alcohol absorption. These results illustrate the high diagnostic sensitivity of the breath analyzer in field-tested conditions. © 2013 American Academy of Forensic Sciences.
Sites, Debra S; Johnson, Nancy T; Miller, Jacqueline A; Torbush, Pauline H; Hardin, Janis S; Knowles, Susan S; Nance, Jennifer; Fox, Tara H; Tart, Rebecca Creech
2014-02-01
With little scientific evidence to support use of aromatherapy for postoperative nausea and/or vomiting (PONV) symptoms, this study evaluated controlled breathing with peppermint aromatherapy (AR) and controlled breathing alone (CB) for PONV relief. A single blind randomized control trial design was used. On initial PONV complaint, symptomatic subjects received either CB (n = 16) or AR (n = 26) intervention based on randomization at enrollment. A second treatment was repeated at 5 minutes if indicated. Final assessment occurred 10 minutes post initial treatment. Rescue medication was offered for persistent symptoms. Among eligible subjects, PONV incidence was 21.4% (42/196). Gender was the only risk factor contributing to PONV symptoms (P = .0024). Though not statistically significant, CB was more efficacious than AR, 62.5% versus 57.7%, respectively. CB can be initiated without delay as an alternative to prescribed antiemetics. Data also support use of peppermint AR in conjunction with CB for PONV relief. Copyright © 2014 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.
Nasal versus face mask for multiple-breath washout technique in preterm infants.
Schulzke, S M; Deeptha, K; Sinhal, S; Baldwin, D N; Pillow, J J
2008-09-01
The large dead space associated with face masks might impede the accuracy and feasibility of multiple-breath washout (MBW) measurements in small infants. We asked if a low dead space nasal mask would provide measurements of resting lung volume and ventilation inhomogeneity comparable to those obtained with a face mask, when using the MBW technique. Unsedated preterm infants breathing without mechanical assistance and weighing between 1.50 and 2.49 kg were studied. Paired MBW tests with nasal and face masks were obtained using sulphur hexafluoride (SF(6)) as the tracer gas. The order of mask application was quasi-randomized. Bland-Altman method and intraclass correlation coefficient were used to analyze outcomes. Measurements were obtained in 20 infants with a mean (SD) postmenstrual age of 36 (1.4) w and a test weight of 2.0 (0.3) kg. The mean difference (95% CI) for nasal vs. face mask was -3.2 breaths/min (-6.2, -0.1 breaths/min) for respiratory rate, -1.0 ml/kg (-2.3, 0.3 ml/kg) for lung volume, 0.6 (0.1, 1.1) for lung clearance index, 0.2 (0.1, 0.3) for first to zeroeth moment ratio and 1.33 (0.6, 2.4) for second to zeroeth moment ratio. Paired measurements of lung volume showed acceptable agreement and good correlation, but there was poor agreement and poor correlation between indices of ventilation inhomogeneity obtained with the two masks. Functional dead space of the nasal mask was similar to that of the face mask despite its smaller water displacement volume. During MBW in infants below 2.5 kg body weight, a nasal mask results in comparable lung volume measurements. Indices of ventilation inhomogeneity may not be directly comparable using masks with different dead space. (c) 2008 Wiley-Liss, Inc.
Police custody following drink-driving: a prospective study.
Lepresle, Aude; Mahindhoratep, Tiao Saysouda; Chiadmi, Fouad; Schlatter, Joël; Boraud, Cyril; Chariot, Patrick
2012-11-01
Drink-driving is a crime and traffic offences are a common cause of detention in police custody. Legal assessment of alcohol intoxication is based on breath or blood testing. We hypothesize that refusal of breath alcohol testing or inability to perform it can correspond to singular medical characteristics of the detainee, possibly assaulted or injured during the arrest. Our objective was to determine medical characteristics of detainees held in custody for drink-driving. Prospective monocentric study (April-October, 2010) of drink-drive arrestees. Controls were persons aged over 18 detained for other reasons than drink-driving. Data collected concerned persons' characteristics and reported assaults or observed injuries. 223 drivers were tested positive for breath alcohol level and 55 suspected drink-drivers refused or were not able to complete breath test. 2212 consecutively examined persons served as controls. Drink-drive arrestees requested medical examination more rarely (18% and 7%, vs. 43%, P<0.0001) and drivers tested positive for breath alcohol were more frequently alcohol abusers (25% vs. 14%, P<0.0001) than controls. Drivers who did not complete breath test more often reported assaults than those tested positive for breath alcohol (22% vs. 8%, P=0.007). They had more frequent traumatic injuries than those tested positive and than controls (29% vs. 11% and 17%, P=0.003 and 0.02). Only 1% of drink drivers were unfit for detention after medical examination. Physicians need to give attentive care to detained drink-drivers. Special attention should be paid to drink-drivers who refused or were not able to complete breath alcohol measurement. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Two-thumb technique is superior to two-finger technique during lone rescuer infant manikin CPR.
Udassi, Sharda; Udassi, Jai P; Lamb, Melissa A; Theriaque, Douglas W; Shuster, Jonathan J; Zaritsky, Arno L; Haque, Ikram U
2010-06-01
Infant CPR guidelines recommend two-finger chest compression with a lone rescuer and two-thumb with two rescuers. Two-thumb provides better chest compression but is perceived to be associated with increased ventilation hands-off time. We hypothesized that lone rescuer two-thumb CPR is associated with increased ventilation cycle time, decreased ventilation quality and fewer chest compressions compared to two-finger CPR in an infant manikin model. Crossover observational study randomizing 34 healthcare providers to perform 2 min CPR at a compression rate of 100 min(-1) using a 30:2 compression:ventilation ratio comparing two-thumb vs. two-finger techniques. A Laerdal Baby ALS Trainer manikin was modified to digitally record compression rate, compression depth and compression pressure and ventilation cycle time (two mouth-to-mouth breaths). Manikin chest rise with breaths was video recorded and later reviewed by two blinded CPR instructors for percent effective breaths. Data (mean+/-SD) were analyzed using a two-tailed paired t-test. Significance was defined qualitatively as p< or =0.05. Mean % effective breaths were 90+/-18.6% in two-thumb and 88.9+/-21.1% in two-finger, p=0.65. Mean time (s) to deliver two mouth-to-mouth breaths was 7.6+/-1.6 in two-thumb and 7.0+/-1.5 in two-finger, p<0.0001. Mean delivered compressions per minute were 87+/-11 in two-thumb and 92+/-12 in two-finger, p=0.0005. Two-thumb resulted in significantly higher compression depth and compression pressure compared to the two-finger technique. Healthcare providers required 0.6s longer time to deliver two breaths during two-thumb lone rescuer infant CPR, but there was no significant difference in percent effective breaths delivered between the two techniques. Two-thumb CPR had 4 fewer delivered compressions per minute, which may be offset by far more effective compression depth and compression pressure compared to two-finger technique. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
49 CFR 219.301 - Testing for reasonable cause.
Code of Federal Regulations, 2010 CFR
2010-10-01
... breath or body fluid testing, or both, to determine compliance with §§ 219.101 and 219.102 or a railroad... an employee that is required when an employee is required to provide a breath or body fluid specimen... breath testing. In addition to reasonable suspicion as described in § 219.300, the following...
49 CFR 219.301 - Testing for reasonable cause.
Code of Federal Regulations, 2011 CFR
2011-10-01
... breath or body fluid testing, or both, to determine compliance with §§ 219.101 and 219.102 or a railroad... an employee that is required when an employee is required to provide a breath or body fluid specimen... breath testing. In addition to reasonable suspicion as described in § 219.300, the following...
Application of LaserBreath-001 for breath acetone measurement in subjects with diabetes mellitus
NASA Astrophysics Data System (ADS)
Wang, Zhennan; Sun, Meixiu; Chen, Zhuying; Zhao, Xiaomeng; Li, Yingxin; Wang, Chuji
2016-11-01
Breath acetone is a promising biomarker of diabetes mellitus. With an integrated standalone, on-site cavity ringdown breath acetone analyzer, LaserBreath-001, we tested breath samples from 23 type 1 diabetic (T1D) patients, 312 type 2 diabetic (T2D) patients, 52 healthy subjects. In the cross-sectional studies, the obtained breath acetone concentrations were higher in the diabetic subjects compared with those in the control group. No correlation between breath acetone and simultaneous BG was observed in the T1D, T2D, and healthy subjects. A moderate positive correlation between the mean individual breath acetone concentrations and the mean individual BG levels was observed in the 20 T1D patients without ketoacidosis. In a longitudinal study, the breath acetone concentrations in a T1D patient with ketoacidosis decreased significantly and remained stable during the 5-day hospitalization. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone concentrations, fast (<1 min) and on site breath acetone measurement can be used for diabetic screening and management under a specifically controlled condition.
Kapus, Jernej; Usaj, Anton; Strumbelj, Boro; Kapus, Venceslav
2008-01-01
The aim of the present study was to ascertain whether maximal 200 m front crawl swimming strategies and breathing patterns influenced blood gas and acid-base parameters in a manner which gives advantage to former competitive swimmers in comparison with their recreational colleagues. Twelve former competitive male swimmers (the CS group) and nine recreational male swimmers (the RS group) performed a maximal 200 m front crawl swimming with self- selected breathing pattern. Stroke rate (SR) and breathing frequency (BF) were measured during the swimming test. Measures also included blood lactate concentration ([LA]) and parameters of blood acid-base status before and during the first minute after the swimming test. The CS group swam faster then the RS group. Both groups have similar and steady SR throughout the swimming test. This was not matched by similar BF in the CS group but matched it very well in the RS group (r = 0.89). At the beginning of swimming test the CS group had low BF, but they increased it throughout the swimming test. The BF at the RS group remained constant with only mirror variations throughout the swimming test. Such difference in velocity and breathing resulted in maintaining of blood Po2 from hypoxia and Pco2 from hypercapnia. This was similar in both groups. [LA] increased faster in the CS group than in the RS group. On the contrary, the rate of pH decrease remained similar in both groups. The former competitive swimmers showed three possible advantages in comparison to recreational swimmers during maximal 200 m front crawl swimming: a more dynamic and precise regulation of breathing, more powerful bicarbonate buffering system and better synchronization between breathing needs and breathing response during swimming. Key pointsTraining programs for competitive swimmers should promote adaptations to maximal efforts.Those adaptations should include high and maximal intensity swims with controlled breathing frequency (taking breath every fourth, fifth, sixth or eighth stroke cycle for front crawl swimming).Such training will improve breathing regulation in order to impose a better synchronization between breathing needs and breathing response during maximal swimming. PMID:24150142
ERIC Educational Resources Information Center
Garner, Pamela W.; Bender, Stacy L.; Fedor, Megan
2018-01-01
Eighty-seven preservice teachers, some of whom had preschool teaching experience, were randomly assigned to an intervention that included training in breathing awareness meditation infused with social-emotional learning (n = 43) or a control group that received training in (n = 44) in breathing awareness meditation only. Both groups showed an…
NASA Astrophysics Data System (ADS)
Wang, Chuji; Surampudi, Anand B.
2008-10-01
We have developed a portable breath acetone analyzer using cavity ringdown spectroscopy (CRDS). The instrument was initially tested by measuring the absorbance of breath gases at a single wavelength (266 nm) from 32 human subjects under various conditions. A background subtraction method, implemented to obtain absorbance differences, from which an upper limit of breath acetone concentration was obtained, is described. The upper limits of breath acetone concentration in the four Type 1 diabetes (T1D) subjects, tested after a 14 h overnight fast, range from 0.80 to 3.97 parts per million by volume (ppmv), higher than the mean acetone concentration (0.49 ppmv) in non-diabetic healthy breath reported in the literature. The preliminary results show that the instrument can tell distinctive differences between the breath from individuals who are healthy and those with T1D. On-line monitoring of breath gases in healthy people post-exercise, post-meals and post-alcohol-consumption was also conducted. This exploratory study demonstrates the first CRDS-based acetone breath analyzer and its potential application for point-of-care, non-invasive, diabetic monitoring.
Calligaro, Gregory L; Raine, Richard I; Bateman, Mary E; Bateman, Eric D; Cooper, Christopher B
2014-02-01
Dynamic hyperinflation (DH) during exercise is associated with both dyspnea and exercise limitation in COPD. Metronome-paced tachypnoea (MPT) is a simple alternative for studying DH. We compared MPT with exercise testing (XT) as methods of provoking DH, and assessed their relationship with dyspnea. We studied 24 patients with moderate COPD (FEV1 59 ± 9% predicted) after inhalation of ipratropium/salbutamol combination or placebo in a double-blind, crossover design. Inspiratory capacity (IC) was measured at baseline and after 30 seconds of MPT with breathing frequencies (fR) of 20, 30 and 40 breaths/min and metronome-defined I:E ratios of 1:1 and 1:2, in random sequence, followed by incremental cycle ergometry with interval determinations of IC. DH was defined as a decline in IC from baseline (∆IC) for both methods. Dyspnea was assessed using a Borg CR-10 scale. ∆IC during MPT was greater with higher fR and I:E ratio of 1:1 versus 1:2, and less when patients were treated with bronchodilator rather than placebo (P = 0.032). DH occurred during 19 (40%) XTs, and during 35 (73%) tests using MPT. Eleven of 18 (61%) non-congruent XTs (where DH occurred on MPT but not XT) terminated before fR of 40 breaths/min was reached. Although greater during XT, the intensity of dyspnea bore no relationship to DH during either MPT and XT. MPT at 40 breaths/min and I:E of 1:1 elicits the greatest ∆IC, and is a more sensitive method for demonstrating DH. The relationship between DH and dyspnea is complex and not determined by DH alone.
Doyle, Todd; Palmer, Scott; Johnson, Julie; Babyak, Michael A.; Smith, Patrick; Mabe, Stephanie; Welty-Wolf, Karen; Martinu, Tereza; Blumenthal, James A.
2014-01-01
Objectives To examine the association of anxiety and depression with pulmonary-specific symptoms of Chronic Obstructive Pulmonary Disease (COPD), and to determine the extent to which disease severity and functional capacity modify this association. Method Patients (N = 162) enrolled in the INSPIRE-II study, an ongoing randomized, clinical trial of COPD patients and their caregivers who received either telephone-based coping skills training or education and symptom monitoring. Patients completed a psychosocial test battery including: Brief Fatigue Inventory, St. George’s Respiratory Questionnaire, UCSD Shortness of Breath Questionnaire, State-Trait Anxiety Inventory, and Beck Depression Inventory. Measures of disease severity and functional capacity (i.e., FEV1 and six-minute walk test) were also obtained. Results After covariate adjustment, higher anxiety and depression levels were associated with greater fatigue levels (ps < .001, ΔR2 = 0.16 and 0.29, respectively), shortness of breath (ps < .001, ΔR2 = 0.12 and 0.10), and frequency of COPD symptoms (ps < .001, ΔR2 = 0.11 and 0.13). In addition, functional capacity was a moderator of anxiety and pulmonary-specific COPD symptoms. The association between anxiety and shortness of breath (p = 0.009) and frequency of COPD symptoms (p = 0.02) was greater among patients with lower functional capacity. Conclusions Anxiety and depression were associated with higher levels of fatigue, shortness of breath, and frequency of COPD symptoms. It is important for clinicians to be aware of the presence of anxiety and depression in COPD patients, which appears to correlate with pulmonary-specific COPD symptoms, especially in patients with lower functional capacity. Prospective design studies are needed to elucidate the causal relationships between anxiety and depression and pulmonary-specific symptoms in COPD patients. PMID:23977821
Clinical applications of breath testing
Paschke, Kelly M; Mashir, Alquam
2010-01-01
Breath testing has the potential to benefit the medical field as a cost-effective, non-invasive diagnostic tool for diseases of the lung and beyond. With growing evidence of clinical worth, standardization of methods, and new sensor and detection technologies the stage is set for breath testing to gain considerable attention and wider application in upcoming years. PMID:21173863
Breath measurement instrumentation as alcohol safety interlock systems
DOT National Transportation Integrated Search
1974-09-01
This report describes the results of field tests of in-car instruments which measure alcohol on the driver's breath and prevent him from operating his vehicle if intoxicated. Two types of breath alcohol sensors were used for these tests; a fuel-cell ...
Merkel, C; Morabito, A; Sacerdoti, D; Bolognesi, M; Angeli, P; Gatta, A
1998-06-01
The determination of aminopyrine breath test on entry into the study was recently shown to improve the accuracy of prediction of death based on the Child-Pugh classification, but the possible usefulness of serial determinations of both parameters has not been assessed. In the present study, we aimed at evaluating whether serial determinations of aminopyrine breath test and Child-Pugh score improve prognostic accuracy in patients with cirrhosis, compared with determinations obtained only on admission. In 74 patients with liver cirrhosis aminopyrine breath test and Child-Pugh score were obtained upon entry into the study. Patients were followed with sequential aminopyrine breath tests and assessments of the Child-Pugh score every 4-6 months. A total number of 232 determinations were obtained. During follow-up 45 patients died, on average after 12 months of follow-up. Child-Pugh score improved in the beginning of follow-up, and then remained fairly constant; aminopyrine breath test showed no improvement in the beginning of follow-up, but rather a slowly progressive decline. In patients who died, both the Child-Pugh score and the metabolism of aminopyrine were significantly more impaired in the last year preceding death (p < 0.05). Applying Cox's regression model with time-dependent covariates, Child-Pugh score and aminopyrine breath test were independent significant predictors of survival. The model with time-dependent covariates explained the observed survival much better than the model with time-fixed covariates (chi-sq. explained by regression = 31.45 vs 11.97; d.f. = 2; p = 0.0000001 vs 0.003). These data suggest that serial determinations of Child-Pugh score and aminopyrine breath test can be used to efficiently update prognosis of cirrhosis.
Mannini, Claudia; Lavorini, Federico; Zanasi, Alessandro; Saibene, Federico; Lanata, Luigi; Fontana, Giovanni
2017-06-01
Cough is produced by the same neuronal pool implicated in respiratory rhythm generation, and antitussive drugs acting at the central level, such as opioids, may depress ventilation. Levodropropizine is classified as a nonopioid peripherally acting antitussive drug that acts at the level of airway sensory nerves. However, the lack of a central action by levodropropizine remains to be fully established. We set out to compare the effects of levodropropizine and the opioid antitussive agent dihydrocodeine on the respiratory responses to a conventional CO 2 rebreathing test in patients with chronic cough of any origin. Twenty-four outpatients (aged 39-70 years) with chronic cough were studied. On separate runs, each patient was randomly administered 60 mg levodropropizine, 15 mg dihydrocodeine, or a matching placebo. Subsequently, patients breathed a mixture of 93% oxygen and 7% CO 2 for 5 min. Fractional end-tidal CO 2 (Fetco 2 ) and inspiratory minute ventilation (V˙i) were continuously monitored. Changes in breathing pattern variables were also assessed. At variance with dihydrocodeine, levodropropizine and placebo did not affect respiratory responses to hypercapnia (P < .01). The ventilatory increases by hypercapnia were mainly accounted for by a rise in the volume components of the breathing pattern. The results are consistent with a peripheral action by levodropropizine; the assessment of ventilatory responses to CO 2 may represent a useful tool to investigate the central respiratory effects of antitussive agents. European Union Clinical Trials Register (EudraCT No.: 2013-004735-68); URL: https://www.clinicaltrialsregister.eu/. Copyright © 2017. Published by Elsevier Inc.
The effect of simulated air conditions on N95 filtering facepiece respirators performance.
Ramirez, Joel A; O'Shaughnessy, Patrick T
2016-07-01
The objective of this study was to determine the effect of several simulated air environmental conditions on the particle penetration and the breathing resistance of two N95 filtering facepiece respirator (FFR) models. The particle penetration and breathing resistance of the respirators were evaluated in a test system developed to mimic inhalation and exhalation breathing while relative humidity and temperature were modified. Breathing resistance was measured over 120 min using a calibrated pressure transducer under four different temperature and relative humidity conditions without aerosol loading. Particle penetration was evaluated before and after the breathing resistance test at room conditions using a sodium chloride aerosol measured with a scanning mobility particle sizer. Results demonstrated that increasing relative humidity and lowering external temperature caused significant increases in breathing resistance (p < 0.001). However, these same conditions did not influence the penetration or most penetrating particle size of the tested FFRs. The increase in breathing resistance varied by FFR model suggesting that some FFR media are less influenced by high relative humidity.
42 CFR 84.88 - Breathing bag test.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...
42 CFR 84.88 - Breathing bag test.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...
42 CFR 84.88 - Breathing bag test.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...
42 CFR 84.88 - Breathing bag test.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...
Prevalence of abnormal lactose breath hydrogen tests in children with functional abdominal pain.
Garg, Neha; Basu, Srikanta; Singh, Preeti; Kumar, Ruchika; Sharma, Lokesh; Kumar, Praveen
2017-05-01
The study was undertaken to determine the prevalence of abnormal lactose breath hydrogen test in children with non-organic chronic abdominal pain. Children with chronic abdominal pain were examined and investigated for organic causes. All children without a known organic cause underwent lactose and glucose breath hydrogen test. After a standard dose of 2 g/kg of lactose to a maximum of 50 g, hydrogen in breath was measured at 15 min intervals for 3 h. A rise of 20 ppm above baseline was considered suggestive of lactose malabsorption. Of 108 children screened, organic causes were found in 46 children. Sixty-two patients without any organic cause underwent hydrogen breath test. Lactose hydrogen breath test (HBT) was positive in 36 of 62 (58%), while 11 (17%) had positive HBT with glucose suggestive of small intestinal bacterial overgrowth (SIBO). Twenty out of 34 (59%) improved on lactose free diet while 8 out of 11 (72%) children of SIBO improved on antibiotics. Lactose malabsorption was seen in 58% of children with non-organic chronic abdominal pain.
New optical analyzer for 13C-breath test
NASA Astrophysics Data System (ADS)
Harde, Hermann; Dressler, Matthias; Helmrich, Günther; Wolff, Marcus; Groninga, Hinrich
2008-04-01
Medical breath tests are well established diagnostic tools, predominantly for gastroenterological inspections, but also for many other examinations. Since the composition and concentration of exhaled volatile gases reflect the physical condition of a patient, a breath analysis allows one to recognize an infectious disease in an organ or even to identify a tumor. One of the most prominent breath tests is the 13C-urea-breath test, applied to ascertain the presence of the bacterium helicobacter pylori in the stomach wall as an indication of a gastric ulcer. In this contribution we present a new optical analyzer that is based on photoacoustic spectroscopy and uses a DFB diode laser at 2.744 μm. The concentration ratio of the CO II isotopologues is determined by measuring the absorption on a 13CO II line in comparison to a 12CO II line. In the specially selected spectral range the lines have similar strengths, although the concentrations differ by a factor of 90. Therefore, the signals are well comparable. Due to an excellent signal-noise-ratio isotope variations of less than 1% can be resolved as required for the breath test.
Charest, Mathieu; Bélair, Marc-André
2017-06-01
Helicobacter pylori infection is the leading cause of peptic ulcer disease. The purpose of this study was, first, to assess the difference in the distribution of negative versus positive results between the older 14 C-urea breath test and the newer 13 C-urea breath test and, second, to determine whether use of an indeterminate-results category is still meaningful and what type of results should trigger repeated testing. Methods: A retrospective survey was performed of all consecutive patients referred to our service for urea breath testing. We analyzed 562 patients who had undergone testing with 14 C-urea and 454 patients who had undergone testing with 13 C-urea. Results: In comparison with the wide distribution of negative 14 C results, negative 13 C results were distributed farther from the cutoff and were grouped more tightly around the mean negative value. Distribution analysis of the negative results for 13 C testing, compared with those for 14 C testing, revealed a statistically significant difference between the two. Within the 13 C group, only 1 patient could have been classified as having indeterminate results using the same indeterminate zone as was used for the 14 C group. This is significantly less frequent than what was found for the 14 C group. Discussion: Borderline-negative results do occur with 13 C-urea breath testing, although less frequently than with 14 C-urea breath testing, and we will be carefully monitoring differences falling between 3.0 and 3.5 %Δ. 13 C-urea breath testing is safe and simple for the patient and, in most cases, provides clearer positive or negative results for the clinician. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Peptic ulcer disease - H. pylori ; PUD - H. pylori ... There are several methods to test for H. pylori infection. Breath Test (Carbon Isotope-urea Breath Test, or UBT) Up to 2 weeks before the test, you need to stop taking ...
Ma, Yong-Jian; Zhang, Hou-De; Wu, Chuang-Hong; Zhu, Guo-Liang; Ji, Yong-Qiang; Huang, Jia-Liang; Du, Li-Tao; Cao, Ping; Zang, De-Yue; Ji, Kun-Mei
2016-08-10
Hemolytic anemia is a major side effect of ribavirin antiviral treatment for chronic hepatitis C. Ribavirin dose reduction may compromise the antiviral response and erythropoietin can take several weeks to alleviate anemia. The purpose of the present study was to screen potentially protective drugs against ribavirin-induced hemolytic anemia in a rabbit model, using our modified CO breath test for measuring erythrocyte (RBC) lifespan, the gold standard diagnostic index of hemolysis. Fifteen rabbits were divided randomly into five groups (N = 3/group): one vehicle control group, one ribavirin (only)-treated (RBV) group, and three groups initially treated with ribavirin only, followed by a combination of ribavirin with prednisone (RBV + Pred), polyene phosphatidyl choline (RBV + PPC), or reduced glutathione (RBV + GSH). RBC lifespan was calculated from accumulated CO measured in a closed rebreath apparatus, blood volume measured by the Evan's blue dye (EBD) dilution test, and hemoglobin concentration data. The RBC lifespan was normal in the vehicle control group (44-60 d), but reduced significantly in all of the ribavirin-treated groups before the addition of screened drugs (17-35 d). RBC lifespan rebounded significantly with the addition of glutathione, but not with the addition of prednisone or polyene phosphatidyl choline. A similar overall drug effect pattern was seen in the hemoglobin concentration and reticulocyte count data. In conclusion, the results of this pilot study indicate that reduced glutathione can attenuate ribavirin-induced hemolytic anemia, and that the RBC lifespan measured with our modified rapid CO breath test is feasible and reliable for use in animal studies.
NASA Technical Reports Server (NTRS)
Bartlett, R. G.; Hendricks, C. M.; Morison, W. B.
1972-01-01
The development of a breathing metabolic simulator (BMS) is reported. This BMS simulates all of the breathing and metabolic parameters required for complete evaluation and test of life support and resuscitation equipment. It is also useful for calibrating and validating mechanical and gaseous pulmonary function test procedures. Breathing rate, breathing depth, breath velocity contour, oxygen uptake, and carbon dioxide release are all variable over wide ranges simulating conditions from sleep to hard work with respiratory exchange ratios covering the range from hypoventilation. In addition, all of these parameters are remotely controllable to facilitate use of the device in hostile or remote environments. The exhaled breath is also maintained at body temperature and a high humidity. The simulation is accurate to the extent of having a variable functional residual capacity independent of other parameters.
Tomich, Georgia Miranda; França, Danielle Corrêa; Diniz, Marco Túlio Costa; Britto, Raquel Rodrigues; Sampaio, Rosana Ferreira; Parreira, Verônica Franco
2010-01-01
To evaluate breathing pattern and thoracoabdominal motion during breathing exercises. Twenty-four patients with class II or III obesity (18 women; 6 men) were studied on the second postoperative day after gastroplasty. The mean age was 37 +/- 11 years, and the mean BMI was 44 +/- 3 kg/m(2). Diaphragmatic breathing, incentive spirometry with a flow-oriented device and incentive spirometry with a volume-oriented device were performed in random order. Respiratory inductive plethysmography was used in order to measure respiratory variables and thoracoabdominal motion. Comparisons among the three exercises showed significant differences: tidal volume was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing; the respiratory rate was lower during incentive spirometry with the volume-oriented device than during incentive spirometry with the flow-oriented device; and minute ventilation was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing. Rib cage motion did not vary during breathing exercises, although there was an increase in thoracoabdominal asynchrony, especially during incentive spirometry with the flow-oriented device. Among the breathing exercises evaluated, incentive spirometry with the volume-oriented device provided the best results, because it allowed slower, deeper inhalation.
The relationship between observed signs of impairment and THC concentration in oral fluid.
Fierro, Inmaculada; González-Luque, Juan Carlos; Alvarez, F Javier
2014-11-01
Studies have shown that cannabis intake increases the risk of traffic accidents. Controlled experiments support these findings and have shown a positive dose-effect relationship. In this retrospective cross-sectional study of data from a roadside survey, we investigated whether a police officer's judgment regarding signs of impairment is related to the concentration of delta-9-tetrahydrocannabinol (THC) in the oral fluid (OF). We investigated 2,632 cases from a representative sample of 3,302 Spanish drivers: 253 drivers positive for THC only, 32 positive for THC and ethanol, 201 with only ethanol detected in their breath, and 2,146 drivers who tested negative for ethanol in breath and drugs in OF. Recorded data comprised breath alcohol concentrations, THC concentrations in the OF, and the 31 observed signs of impairment. Subject groups were compared using the chi-square test, and logistic regression was used to examine the risk of being categorized as exhibiting signs of impairment. A relationship was found between the OF THC concentration and some observed signs of impairment. Eye signs were noticeable from a THC concentration >3.0 ng/ml in OF, and >25 ng/ml was related to behavior, facial expression, and speech signs. Alcohol and THC contribute to impairment independently and, when taken simultaneously, the effects are comparable to the sum of the effects when consumed separately. The observation of signs of impairment due to cannabis occurs in an OF concentration-related manner but, as a clinical test, OF has low sensitivity and specificity in a random roadside survey. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
[Application of the breath hydrogen test in gastroenterology].
Loranskaia, I D; Panina, N A; Zheltakova, O V
2006-01-01
The diagnostic capacities of the breath hydrogen test in gastroenterology are discussed in the article. The authors describe the results of their own research--determination of the intestinal bacterial contamination in patients with chronic biliary pancreatitis with the help of the Micro H2 breath hydrogen analyzer.
Breathing simulator of workers for respirator performance test.
Yuasa, Hisashi; Kumita, Mikio; Honda, Takeshi; Kimura, Kazushi; Nozaki, Kosuke; Emi, Hitoshi; Otani, Yoshio
2015-01-01
Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker's respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns.
van Oort, Pouline M P; Nijsen, Tamara; Weda, Hans; Knobel, Hugo; Dark, Paul; Felton, Timothy; Rattray, Nicholas J W; Lawal, Oluwasola; Ahmed, Waqar; Portsmouth, Craig; Sterk, Peter J; Schultz, Marcus J; Zakharkina, Tetyana; Artigas, Antonio; Povoa, Pedro; Martin-Loeches, Ignacio; Fowler, Stephen J; Bos, Lieuwe D J
2017-01-03
The diagnosis of ventilator-associated pneumonia (VAP) remains time-consuming and costly, the clinical tools lack specificity and a bedside test to exclude infection in suspected patients is unavailable. Breath contains hundreds to thousands of volatile organic compounds (VOCs) that result from host and microbial metabolism as well as the environment. The present study aims to use breath VOC analysis to develop a model that can discriminate between patients who have positive cultures and who have negative cultures with a high sensitivity. The Molecular Analysis of Exhaled Breath as Diagnostic Test for Ventilator-Associated Pneumonia (BreathDx) study is a multicentre observational study. Breath and bronchial lavage samples will be collected from 100 and 53 intubated and ventilated patients suspected of VAP. Breath will be analysed using Thermal Desorption - Gas Chromatography - Mass Spectrometry (TD-GC-MS). The primary endpoint is the accuracy of cross-validated prediction for positive respiratory cultures in patients that are suspected of VAP, with a sensitivity of at least 99% (high negative predictive value). To our knowledge, BreathDx is the first study powered to investigate whether molecular analysis of breath can be used to classify suspected VAP patients with and without positive microbiological cultures with 99% sensitivity. UKCRN ID number 19086, registered May 2015; as well as registration at www.trialregister.nl under the acronym 'BreathDx' with trial ID number NTR 6114 (retrospectively registered on 28 October 2016).
Hope, Håvar; Skar, Viggo; Sandstad, Olav; Husebye, Einar; Medhus, Asle W
2012-04-01
The ¹⁴C-D-xylose breath test was used at Ullevål University Hospital in the period from 1986 TO 1995 for malabsorption testing. The objective of this retrospective study was to reveal whether patients with chronic alcoholism may have intestinal malabsorption. The consecutive ¹⁴C-D-xylose breath test database was reviewed and patients with the diagnosis of chronic alcoholism were identified. ¹⁴C-D-xylose breath test results of the alcoholic patients were compared with the results of untreated celiac patients and patient and healthy controls. In the ¹⁴C-D-xylose breath test, ¹⁴C-D-xylose was dissolved in water and given orally after overnight fast. Breath samples were taken at 30-min intervals for 210 min, and ¹⁴CO₂ : ¹²CO₂ ratios were calculated for each time point, presenting a time curve for ¹⁴C-D-xylose absorption. Urine was collected after 210 min and the fraction of the total d-xylose passed was calculated (U%). ¹⁴CO₂ in breath and ¹⁴C-D-xylose in urine were analyzed using liquid scintillation. Both breath and urine analysis revealed a pattern of malabsorption in alcoholics comparable with untreated celiac patients, with significantly reduced absorption of d-xylose compared with patient and healthy controls. Alcoholic patients have a significantly reduced ¹⁴C-D-xylose absorption, comparable with untreated celiac patients. This indicates a reduced intestinal function in chronic alcoholism.
Parra, Dolores; González, Alvaro; Martínez, J Alfredo; Labayen, Idoia; Díez, Nieves
2003-04-01
The 2-keto[1-(13)C]isocaproate breath test has been proposed as a tool to detect mitochondrial dysfunction in alcoholic liver disease. The aim of this study was to evaluate if the 2-keto[1-(13)C]isocaproate breath test could detect in vivo dynamic changes on mitochondrial activity due to caloric restriction in obese women. Fifteen obese women (body mass index [BMI] > 30 kg/m(2)) participated in the study at baseline. Ten of these women agreed to participate on a diet program to induce body weight loss. Fifteen lean women (BMI < 25 kg/m(2)) were included as a control group. The breath test was performed by the oral administration of the tracer measuring (13)CO(2) enrichment in breath before and after ingestion using isotope ratio mass spectrometry. Body composition, resting energy expenditure, and plasma levels of insulin and leptin were measured. There were no relationships observed between the 2-keto[1-(13)C]isocaproate breath test and the plasma insulin (before diet: P =.863; after diet: P =.879), or leptin (before diet: P =.500; after diet: P =.637). In obese women before treatment, kilograms of fat free mass (P =.108), resting energy expenditure adjusted for body composition (P =.312), and the 2-keto[1-(13)C]isocaproate breath test (P =.205) were similar in comparison to lean women. However, 2-keto[1-(13)C]isocaproate oxidation tended to increase after dieting and was significantly higher than in controls (P =.015). These data suggest that the 2-keto[1-(13)C]isocaproate breath test reflected the adaptive modifications in mitochondrial oxidation in response to caloric restriction in obese women. Copyright 2003 Elsevier, Inc. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-10-01
... test using a saliva ASD or a breath tube ASD? 40.245 Section 40.245 Transportation Office of the... Alcohol Screening Tests § 40.245 What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD? (a) As the STT or BAT, you must take the following steps when using the saliva...
A nanomaterial-based breath test for distinguishing gastric cancer from benign gastric conditions.
Xu, Z-q; Broza, Y Y; Ionsecu, R; Tisch, U; Ding, L; Liu, H; Song, Q; Pan, Y-y; Xiong, F-x; Gu, K-s; Sun, G-p; Chen, Z-d; Leja, M; Haick, H
2013-03-05
Upper digestive endoscopy with biopsy and histopathological evaluation of the biopsy material is the standard method for diagnosing gastric cancer (GC). However, this procedure may not be widely available for screening in the developing world, whereas in developed countries endoscopy is frequently used without major clinical gain. There is a high demand for a simple and non-invasive test for selecting the individuals at increased risk that should undergo the endoscopic examination. Here, we studied the feasibility of a nanomaterial-based breath test for identifying GC among patients with gastric complaints. Alveolar exhaled breath samples from 130 patients with gastric complaints (37 GC/32 ulcers / 61 less severe conditions) that underwent endoscopy/biopsy were analyzed using nanomaterial-based sensors. Predictive models were built employing discriminant factor analysis (DFA) pattern recognition, and their stability against possible confounding factors (alcohol/tobacco consumption; Helicobacter pylori) was tested. Classification success was determined (i) using leave-one-out cross-validation and (ii) by randomly blinding 25% of the samples as a validation set. Complementary chemical analysis of the breath samples was performed using gas chromatography coupled with mass spectrometry. Three DFA models were developed that achieved excellent discrimination between the subpopulations: (i) GC vs benign gastric conditions, among all the patients (89% sensitivity; 90% specificity); (ii) early stage GC (I and II) vs late stage (III and IV), among GC patients (89% sensitivity; 94% specificity); and (iii) ulcer vs less severe, among benign conditions (84% sensitivity; 87% specificity). The models were insensitive against the tested confounding factors. Chemical analysis found that five volatile organic compounds (2-propenenitrile, 2-butoxy-ethanol, furfural, 6-methyl-5-hepten-2-one and isoprene) were significantly elevated in patients with GC and/or peptic ulcer, as compared with less severe gastric conditions. The concentrations both in the room air and in the breath samples were in the single p.p.b.v range, except in the case of isoprene. The preliminary results of this pilot study could open a new and promising avenue to diagnose GC and distinguish it from other gastric diseases. It should be noted that the applied methods are complementary and the potential marker compounds identified by gas-chromatography/mass spectrometry are not necessarily responsible for the differences in the sensor responses. Although this pilot study does not allow drawing far-reaching conclusions, the encouraging preliminary results presented here have initiated a large multicentre clinical trial to confirm the observed patterns for GC and benign gastric conditions.
Kent, Dorothea Stark; Remer, Thomas; Blumenthal, Caron; Hunt, Sharon; Simonds, Sharon; Egert, Sarah; Gaskin, Kevin J
2018-05-01
The 'gold standard' test for the indirect determination of pancreatic function status in infants with cystic fibrosis (CF), the 72-hour fecal fat excretion test, is likely to become obsolete in the near future. Alternative indirect pancreatic function tests with sufficient sensitivity and specificity to determine pancreatic phenotype need further evaluation in CF infants. Evaluation of the clinical utility of both the noninvasive, nonradioactive C-mixed triglyceride (MTG) breath test and fecal elastase-1 (FE1) in comparison with the 72-hour fecal fat assessment in infants with CF. C-MTG breath test and the monoclonal and polyclonal FE1 assessment in stool was compared with the 72-hour fecal fat assessment in 24 infants with CF. Oral pancreatic enzyme substitution (PERT; if already commenced) was stopped before the tests. Sensitivity rates between 82% and 100% for CF patients with pancreatic insufficiency assessed by both the C-MTG breath test and the FE1 tests proved to be high and promising. The C-MTG breath test (31%-38%) as well as both FE1 tests assessed by the monoclonal (46%-54%) and the polyclonal (45%) ELISA kits, however, showed unacceptably low-sensitivity rates for the detection of pancreatic-sufficient CF patients in the present study. The C-MTG breath test with nondispersive infrared spectroscopy (NDIRS) technique, as well as both FE1 tests, are not alternatives to the fecal fat balance test for the evaluation of pancreatic function in CF infants during the first year of life.
NASA Technical Reports Server (NTRS)
Chen, M. H.; Berger, R. D.; Saul, J. P.; Stevenson, K.; Cohen, R. J.
1987-01-01
We report a new method for the noninvasive characterization of the frequency response of the autonomic nervous system (ANS) in mediating fluctuations in heart rate (HR). The approach entails computation of the transfer function magnitude and phase between instantaneous lung volume and HR. Broad band fluctuations in lung volume were initiated when subjects breathed on cue to a sequence of beeps spaced randomly in time. We studied 10 subjects in both supine and standing positions. The transfer function, averaged among all the subjects, showed systematic differences between the two postures, reflecting the differing frequency responses of the sympathetic and parasympathetic divisions of the ANS.
Ignacio-García, José M; Ignacio-García, Juan M; Almenara-Barrios, José; Chocrón-Giraldez, María J; Hita-Iglesias, Carmen
2005-01-01
Because most bronchodilator inhalers contain propellant gases or a small amount of ethanol as a co-solvent, the potential for these products to generate false readings on a evidential breath alcohol instrument was evaluated in 69 volunteers with clinically stable asthma. All subjects underwent a breath test on an infrared breath alcohol analyzer (Alcotest 7110, Dräger, Lübeck, Germany) before the use of the asthma inhaler and 1 and 5 min after inhalation. The effects of antiasthmatic medications delivered by metered dose inhalers (MDIs) with alcohol as a vehicle, alcohol-free MDIs, and dry powder inhalers were assessed in homogeneous groups of four to five patients. All subjects were alcohol-free on the preliminary breath test. One minute after inhalation, negative readings were only observed in 25 (36.2%) of subjects. In 62.3% of patients, apparent alcohol results were considered interferences or unstable readings by the breath-test instrument. One subject showed a final positive breath alcohol level (0.07 mg/L). After the use of dry powder inhalers, valid results without interferences were obtained. However, 89.6% of patients in which bronchodilators were delivered by MDIs (with propellant gases in the aerosol) showed altered partial readings and labeled the final output as "invalid," but tests performed 5 min after the use of inhalers were valid and correct in all cases. MDIs with propellants as a vehicle may cause false positive breath alcohol readings in some patients. These effects are transient and may be prevented by a 5-10-min interval between the use of MDIs and breath alcohol testing.
Ventilatory muscle endurance training in quadriplegia: effects on breathing pattern.
Loveridge, B; Badour, M; Dubo, H
1989-10-01
We examined the effects of ventilatory muscle endurance training on resting breathing pattern in 12 C6-C7 traumatic quadriplegics at least 1 year post-injury. All subjects had complete motor loss below the lesion level. Subjects were randomly assigned to a training (N = 6), or a control group (N = 6). Baseline tests included measurement of resting ventilation and breathing pattern using mercury in rubber strain gauges for 20 minutes in a seated position; maximum inspiratory mouth pressure (MIP) at FRC, and sustainable inspiratory mouth pressure for 10 minutes (SIP); lung volumes, and arterial blood gases (ABG's). The training protocol consisted of breathing through an inspiratory resistor equivalent to 85% SIP for 15 minutes twice daily, 5 days a week for 8 weeks. Both trainers and controls attended the lab every 2 weeks for reassessment of MIP and SIP and the inspiratory resistance was increased in the training group as SIP increased. At the end of 8 weeks, baseline tests were repeated. All subjects had normal ABG's. There was a significant increase in mean MIP and SIP in both the control group (30% +/- 19% and 31% +/- 18% respectively), and in the training group (42% +/- 24% and 78% +/- 49% respectively). Although the absolute values for both MIP and SIP were greater in the training group than in the control group, the differences were not significant. The alterations in resting breathing pattern were also the same in both groups. Mean frequency decreased significantly in the control group (20.2/minute to 16.9/minute) and, while insignificant, the change in frequency in the training group was the same, 19.4/minute to 16.4/minute. Mean tidal volume (Vt) increased 18.2% of baseline Vt in the control group and 17.0% baseline in the trainers, resulting in no change in minute ventilation. As MIP and SIP increased similarly in both groups, the data from the control and trainers was pooled and timing changes re-evaluated pre- and post-study. A significant decrease in mean Ti/Ttot was observed, while no change in Vt/Ti was found. We concluded that the testing procedure itself provided the stimulus resulting in a significant increase in MIP and SIP. The addition of training did not increase MIP and SIP further. The increased MIP and SIP resulted in a slower and deeper breathing pattern and a significantly shorter Ti/Ttot in both trainers and control subjects.
Kentgens, Anne-Christianne; Guidi, Marisa; Korten, Insa; Kohler, Lena; Binggeli, Severin; Singer, Florian; Latzin, Philipp; Anagnostopoulou, Pinelopi
2018-05-01
Multiple breath washout (MBW) is a sensitive test to measure lung volumes and ventilation inhomogeneity from infancy on. The commonly used setup for infant MBW, based on ultrasonic flowmeter, requires extensive signal processing, which may reduce robustness. A new setup may overcome some previous limitations but formal validation is lacking. We assessed the feasibility of infant MBW testing with the new setup and compared functional residual capacity (FRC) values of the old and the new setup in vivo and in vitro. We performed MBW in four healthy infants and four infants with cystic fibrosis, as well as in a Plexiglas lung simulator using realistic lung volumes and breathing patterns, with the new (Exhalyzer D, Spiroware 3.2.0, Ecomedics) and the old setup (Exhalyzer D, WBreath 3.18.0, ndd) in random sequence. The technical feasibility of MBW with the new device-setup was 100%. Intra-subject variability in FRC was low in both setups, but differences in FRC between the setups were considerable (mean relative difference 39.7%, range 18.9; 65.7, P = 0.008). Corrections of software settings decreased FRC differences (14.0%, -6.4; 42.3, P = 0.08). Results were confirmed in vitro. MBW measurements with the new setup were feasible in infants. However, despite attempts to correct software settings, outcomes between setups were not interchangeable. Further work is needed before widespread application of the new setup can be recommended. © 2018 Wiley Periodicals, Inc.
Diaphragmatic fatigue in normoxia and hyperoxia.
Pardy, R L; Bye, P T
1985-03-01
Diaphragmatic fatigue was induced in six normal young men inspiring against a variable alinear resistance. Breathing pattern was rigidly controlled (tidal volume 0.75 liter, 12 breaths . min-1). Fatigue was defined as an inability to continue to generate a target transdiaphragmatic pressure (Pdi = 0.65 - 0.84 Pdimax). Diaphragmatic electromyogram (EMG, esophageal electrode) and perceived effort (PE, open-ended scale) were recorded. Subjects were tested on an identical resistance inspiring air or 100% O2 in random order on different days. They were unaware of the gas mixture inspired. Mean endurance time (tlim) +/- SE for air was 4.1 +/- 1.4 min and for O2 was 8.6 +/- 2.7 min (P less than 0.005). The increased tlim in O2 was associated with a delay in onset of EMG changes heralding diaphragmatic fatigue and a decrease in PE at any time during the study compared with the level of PE in air. Arterial O2 saturation (ear oximeter) remained at the resting level of 99.0 +/- 0.2% in O2 and decreased from the resting level of 97.2 +/- 0.2% by 2.8 +/- 0.7% (P less than 0.01) in air. The end-tidal CO2 fraction increased to a similar degree in air and O2 studies. We conclude that when breathing pattern, minute ventilation, and Pdi are held constant during inspiratory resistive loading, breathing O2 delays the onset of diaphragm fatigue and decreases PE.
Breathing simulator of workers for respirator performance test
YUASA, Hisashi; KUMITA, Mikio; HONDA, Takeshi; KIMURA, Kazushi; NOZAKI, Kosuke; EMI, Hitoshi; OTANI, Yoshio
2014-01-01
Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker’s respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns. PMID:25382381
Gastrointestinal transit, post-prandial lipaemia and satiety following 3 days high-fat diet in men.
Clegg, M E; McKenna, P; McClean, C; Davison, G W; Trinick, T; Duly, E; Shafat, A
2011-02-01
High-fat (HF) diets of 2 weeks have been shown to accelerate gastric emptying (GE). To date, no studies have shown any alteration in GE following shorter HF diets. The aim of this study was to assess if an HF, high-energy diet of 3 days can adapt gastrointestinal (GI) transit, blood lipids and satiety. Eleven male volunteers participated in a study consisting of three, 3-day interventions each separated by a test day. During the first intervention, volunteers recorded their diet. In the second and third interventions, volunteers repeated their food diary plus either a low-fat yogurt or HF yogurt supplement in randomized order. Test days involved measurement of GE using the (13)C octanoic-acid breath-test, mouth-to-caecum transit time (MCTT) using the inulin H(2) breath test and satiety using visual analogue scales. Blood samples for measurement of lipaemia were taken using a venous cannula. MCTT was different between the three test days (P=0.038), with the shortest MCTT following the HF intervention. GE was shortest following the HF intervention. There were no differences in satiety between the interventions. The HF intervention reduced triglycerides, total cholesterol and low-density lipoprotein cholesterol, and increased high-density lipoprotein cholesterol. This study shows that changes in GI transit owing to an HF diet can occur in a time period as short as 3 days.
Stability of (13) C-Urea Breath Test Samples Over Time in the Diagnosis of Helicobacter pylori.
Perets, Tsachi Tsadok; Shporn, Einav; Boltin, Doron; Dickman, Ram; Niv, Yaron
2016-05-01
The accuracy and repeatability of breath test in the diagnosis of Helicobacter pylori infection have not been adequately investigated. Although it has been shown that storage for long periods does not affect the analysis results, no data are available on the effect of repetitive testing. In this study, our aim was to evaluate the repeatability of the analyses of breath samples at room temperature. A total of 202 positive breath samples were collected in duplicates, before and after administration of 75 mg (13) C- urea dissolved in 100 ml of orange juice. Breath test results were expressed as delta (13) CO2 . The cut-off value was 3.5 parts per thousand. Each sample was analyzed in a mass spectrometer 7, 14, 21, and 28 days after collection. The accuracy calculation was based on the comparison of the delta (13) CO2 obtained in the three consecutive weeks following the first test run to the delta (13) CO2 obtained in the first test run. Two hundred (99%), 197 (97.52%), and 196 (97%) of the 202 samples tested positive in the second, third, and fourth test runs, respectively. The accuracy of the delta (13) CO2 was 98.6%, 99.2%, and 96.7% in the three consecutive runs, respectively. Short-term storage of 1 month does not affect sample stability or the results of (13) C-urea breath tests in up to three consecutive repeats. © 2015 Wiley Periodicals, Inc.
Control of gill ventilation and air-breathing in the bowfin amia calva
Hedrick; Jones
1999-01-01
The purpose of this study was to investigate the roles of branchial and gas bladder reflex pathways in the control of gill ventilation and air-breathing in the bowfin Amia calva. We have previously determined that bowfin use two distinct air-breathing mechanisms to ventilate the gas bladder: type I air breaths are characterized by exhalation followed by inhalation, are stimulated by aquatic or aerial hypoxia and appear to regulate O2 gas exchange; type II air breaths are characterized by inhalation alone and possibly regulate gas bladder volume and buoyancy. In the present study, we test the hypotheses (1) that gill ventilation and type I air breaths are controlled by O2-sensitive chemoreceptors located in the branchial region, and (2) that type II air breaths are controlled by gas bladder mechanosensitive stretch receptors. Hypothesis 1 was tested by examining the effects of partial or complete branchial denervation of cranial nerves IX and X to the gill arches on gill ventilation frequency (fg) and the proportion of type I air breaths during normoxia and hypoxia; hypothesis II was tested by gas bladder inflation and deflation. Following complete bilateral branchial denervation, fg did not differ from that of sham-operated control fish; in addition, fg was not significantly affected by aquatic hypoxia in sham-operated or denervated fish. In sham-operated fish, aquatic hypoxia significantly increased overall air-breathing frequency (fab) and the percentage of type I breaths. In fish with complete IX-X branchial denervation, fab was also significantly increased during aquatic hypoxia, but there were equal percentages of type I and type II air breaths. Branchial denervation did not affect the frequency of type I air breaths during aquatic hypoxia. Gas bladder deflation via an indwelling catheter resulted in type II breaths almost exclusively; furthermore, fab was significantly correlated with the volume removed from the gas bladder, suggesting a volume-regulating function for type II air breaths. These results indicate that chronic (3-4 weeks) branchial denervation does not significantly affect fg or type I air-breathing responses to aquatic hypoxia. Because type I air-breathing responses to aquatic hypoxia persist after IX-X cranial nerve denervation, O2-sensitive chemoreceptors that regulate air-breathing may be carried in other afferent pathways, such as the pseudobranch. Gas bladder deflation reflexly stimulates type II breaths, suggesting that gas bladder volume-sensitive stretch receptors control this particular air-breathing mechanism. It is likely that type II air breaths function to regulate buoyancy when gas bladder volume declines during the inter-breath interval.
Anand, R.
2016-01-01
Objective. To evaluate the effects of diaphragmatic breathing exercises and flow and volume-oriented incentive spirometry on pulmonary function and diaphragm excursion in patients undergoing laparoscopic abdominal surgery. Methodology. We selected 260 patients posted for laparoscopic abdominal surgery and they were block randomization as follows: 65 patients performed diaphragmatic breathing exercises, 65 patients performed flow incentive spirometry, 65 patients performed volume incentive spirometry, and 65 patients participated as a control group. All of them underwent evaluation of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow Rate (PEFR), and diaphragm excursion measurement by ultrasonography before the operation and on the first and second postoperative days. With the level of significance set at p < 0.05. Results. Pulmonary function and diaphragm excursion showed a significant decrease on the first postoperative day in all four groups (p < 0.001) but was evident more in the control group than in the experimental groups. On the second postoperative day pulmonary function (Forced Vital Capacity) and diaphragm excursion were found to be better preserved in volume incentive spirometry and diaphragmatic breathing exercise group than in the flow incentive spirometry group and the control group. Pulmonary function (Forced Vital Capacity) and diaphragm excursion showed statistically significant differences between volume incentive spirometry and diaphragmatic breathing exercise group (p < 0.05) as compared to that flow incentive spirometry group and the control group. Conclusion. Volume incentive spirometry and diaphragmatic breathing exercise can be recommended as an intervention for all patients pre- and postoperatively, over flow-oriented incentive spirometry for the generation and sustenance of pulmonary function and diaphragm excursion in the management of laparoscopic abdominal surgery. PMID:27525116
Alaparthi, Gopala Krishna; Augustine, Alfred Joseph; Anand, R; Mahale, Ajith
2016-01-01
Objective. To evaluate the effects of diaphragmatic breathing exercises and flow and volume-oriented incentive spirometry on pulmonary function and diaphragm excursion in patients undergoing laparoscopic abdominal surgery. Methodology. We selected 260 patients posted for laparoscopic abdominal surgery and they were block randomization as follows: 65 patients performed diaphragmatic breathing exercises, 65 patients performed flow incentive spirometry, 65 patients performed volume incentive spirometry, and 65 patients participated as a control group. All of them underwent evaluation of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow Rate (PEFR), and diaphragm excursion measurement by ultrasonography before the operation and on the first and second postoperative days. With the level of significance set at p < 0.05. Results. Pulmonary function and diaphragm excursion showed a significant decrease on the first postoperative day in all four groups (p < 0.001) but was evident more in the control group than in the experimental groups. On the second postoperative day pulmonary function (Forced Vital Capacity) and diaphragm excursion were found to be better preserved in volume incentive spirometry and diaphragmatic breathing exercise group than in the flow incentive spirometry group and the control group. Pulmonary function (Forced Vital Capacity) and diaphragm excursion showed statistically significant differences between volume incentive spirometry and diaphragmatic breathing exercise group (p < 0.05) as compared to that flow incentive spirometry group and the control group. Conclusion. Volume incentive spirometry and diaphragmatic breathing exercise can be recommended as an intervention for all patients pre- and postoperatively, over flow-oriented incentive spirometry for the generation and sustenance of pulmonary function and diaphragm excursion in the management of laparoscopic abdominal surgery.
Russell, W C; Greer, J R
2000-11-01
To assess the subjective feeling of comfort of healthy volunteers breathing on various modes of ventilation used in intensive care. A randomized, prospective, double-blinded, crossover trial using volunteers. An intensive care unit (ICU) in a teaching hospital. We compared, by using healthy volunteers, the subjective feeling of comfort of three modes of ventilation used during the weaning phase of critical illness. We used healthy volunteers to avoid other distracting influences of intensive care that may confound the primary feeling of comfort. The modes we compared were synchronized intermittent mandatory ventilation, assisted spontaneous breathing, and biphasic positive airway pressure. The imposed ventilation was comparable with 50% of the volunteers' normal respiratory effort. The volunteers breathed via a mouthpiece through a ventilator circuit, and the modes of ventilation were introduced in a randomized manner. We measured visual analog scores for comfort for the three modes of ventilation and collected a ranking order and open-ended comments. We demonstrated that at the level of support we imposed, assisted spontaneous breathing was the most comfortable mode of ventilation and that synchronized intermittent mandatory ventilation was the most uncomfortable. These results were strongly supported by both the ranking scale and comments of the volunteers. Assisted spontaneous breathing was the most comfortable mode of ventilation because the pattern was primarily determined by the volunteer. Synchronized intermittent mandatory ventilation was the most uncomfortable because the ventilatory pattern was imposed on the volunteers, leading to ventilator-volunteer dyssynchrony. We also conclude there is wide individual variation in the subjective feeling of comfort. Whereas the mode of ventilation in ICUs is based primarily on the physiologic needs of the patient, the feeling of comfort may be considered when choosing an appropriate mode of ventilation during the weaning phase of critical illness.
A Ringdown Breath Analyzer for Diabetes Monitoring: Breath Acetone in Diabetic Patients.
NASA Astrophysics Data System (ADS)
Wang, Chuji; Mbi, Armstrong; Shepherd, Mark
2008-03-01
It is highly desirable for millions of diabetic patients to have a non-blood, non-invasive, point-of-care device for monitoring daily blood glucose (BG) levels and the adequacy of diabetic treatment and control. Cavity ringdown spectroscopy, due to its unique capability of high sensitivity, fast-response, and relatively low cost for instrumentation, has the potential for medical application through non-invasive analysis of breath biomarkers. We report the first ringdown acetone breath analyzer for clinic testing with diabetic outpatients. The instrument was set in a clinic center and 34 outpatients (24 T1D and 10 T2D) were tested during a four-day period. 10 T1D subjects and 15 nondiabetic persons were tested in our laboratory. Three juvenile-onset T1D subjects were selected for a 24-hr monitoring on the variations of breath acetone and simultaneous BG level. In this talk, we present our research findings including the correlations of breath acetone with BG level and A1C.
Bures, J; Kopácová, M; Vorísek, V; Bukac, J; Neumann, D; Rejchrt, S; Pozler, O; Douda, T; Zivný, P; Palicka, V
2005-01-01
13C-octanoic acid breath test (13C-OABT) is a simple, safe and non-invasive technique for measuring gastric emptying. However, the method has not been standardized yet. Aim of the study was to work up, introduce and evaluate our own method of the 13C-OABT for adults. Ten healthy volunteers entered the study (5 men, 5 women, mean age 32 years, 50 % Helicobacter pylori positive). Standard test meals (with 100 mg 13C-sodium octanoate) were used three times within 3 weeks. The same solid meal (1,178 kJ) for Tests 1 and 2 contained scrambled egg (+ 3 g oil), white bread (40 g), butter (10 g) and distilled water (200 ml). Semi-solid meal (1,020 kJ) for Test 3 contained milk pudding (200 g) and distilled water (200 ml). Duplicate breath samples were obtained before and every 15 minutes after eating the test meal during 255 minutes. Altogether 1,080 breath samples were analysed twice (isotope ratio mass spectrometry, AP2003 Analytical Precision, UK). To assess the half-life of elimination (t1/2 E), we modelled the process of elimination with the incomplete gamma-function, which has a convenient form for the empiric plotting of breath test data. Mean t1/2E was 136+/-10 minutes (Test 1), 134+/-14 (Test 2) and 123+/-16 minutes (Test 3). Clinical reproducibility of 13C-OABT in particular persons was 98.2% (18 breath samples series), 90.8 % (15 samples) and 87.1% (9 breath samples series). There was a significant correlation between Test 1 and Test 2 results (r=0.887, p<0.0001). Mean difference of duplicate breath sample analysis was 1.460 % (in 540 pairs), mean baseline one-day analysis difference was 0.0982 (99.9274% accuracy). In healthy volunteers, normal range of t1/2E is 110-160 minutes for solids and 91-155 minutes for semisolid test meal. Using our own computed mean time of intermediate metabolism of 13C-octanoic acid (76.5+/-7.5 minutes), gastric emptying half-time is 33.5-83.5 minutes for solids and 14.5-78.5 minutes for semisolid test meal in healthy volunteers. The 13C-OABT is accurate non-invasive method for gastric emptying measurement.
Yoshida, Takeshi; Uchiyama, Akinori; Matsuura, Nariaki; Mashimo, Takashi; Fujino, Yuji
2012-05-01
We investigated whether potentially injurious transpulmonary pressure could be generated by strong spontaneous breathing and exacerbate lung injury even when plateau pressure is limited to <30 cm H2O. Prospective, randomized, animal study. University animal research laboratory. Thirty-two New Zealand White rabbits. Lavage-injured rabbits were randomly allocated to four groups to receive low or moderate tidal volume ventilation, each combined with weak or strong spontaneous breathing effort. Inspiratory pressure for low tidal volume ventilation was set at 10 cm H2O and tidal volume at 6 mL/kg. For moderate tidal volume ventilation, the values were 20 cm H2O and 7-9 mL/kg. The groups were: low tidal volume ventilation+spontaneous breathingweak, low tidal volume ventilation+spontaneous breathingstrong, moderate tidal volume ventilation+spontaneous breathingweak, and moderate tidal volume ventilation+spontaneous breathingstrong. Each group had the same settings for positive end-expiratory pressure of 8 cm H2O. Respiratory variables were measured every 60 mins. Distribution of lung aeration and alveolar collapse were histologically evaluated. Low tidal volume ventilation+spontaneous breathingstrong showed the most favorable oxygenation and compliance of respiratory system, and the best lung aeration. By contrast, in moderate tidal volume ventilation+spontaneous breathingstrong, the greatest atelectasis with numerous neutrophils was observed. While we applied settings to maintain plateau pressure at <30 cm H2O in all groups, in moderate tidal volume ventilation+spontaneous breathingstrong, transpulmonary pressure rose >33 cm H2O. Both minute ventilation and respiratory rate were higher in the strong spontaneous breathing groups. Even when plateau pressure is limited to <30 cm H2O, combined with increased respiratory rate and tidal volume, high transpulmonary pressure generated by strong spontaneous breathing effort can worsen lung injury. When spontaneous breathing is preserved during mechanical ventilation, transpulmonary pressure and tidal volume should be strictly controlled to prevent further lung injury.
Limited electromagnetic interference testing of evidential breath testers
DOT National Transportation Integrated Search
1983-05-06
This report summarizes a limited test program conducted to determine the susceptibility of evidential breath testers (EBTs) to radio frequency interference (RFI). Several comprehensive test protocols were prepared based on procedures developed by the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laugeman, E; Weiss, E; Chen, S
2014-06-01
Purpose: Evaluate and compare the cycle-to-cycle consistency of breathing patterns and their reproducibility over the course of treatment, for supine and prone positioning. Methods: Respiratory traces from 25 patients were recorded for sequential supine/prone 4DCT scans acquired prior to treatment, and during the course of the treatment (weekly or bi-weekly). For each breathing cycle, the average(AVE), end-of-exhale(EoE) and end-of-inhale( EoI) locations were identified using in-house developed software. In addition, the mean values and variations for the above quantities were computed for each breathing trace. F-tests were used to compare the cycle-to-cycle consistency of all pairs of sequential supine and pronemore » scans. Analysis of variances was also performed using population means for AVE, EoE and EoI to quantify differences between the reproducibility of prone and supine respiration traces over the treatment course. Results: Consistency: Cycle-to-cycle variations are less in prone than supine in the pre-treatment and during-treatment scans for AVE, EoE and EoI points, for the majority of patients (differences significant at p<0.05). The few cases where the respiratory pattern had more variability in prone appeared to be random events. Reproducibility: The reproducibility of breathing patterns (supine and prone) improved as treatment progressed, perhaps due to patients becoming more comfortable with the procedure. However, variability in supine position continued to remain significantly larger than in prone (p<0.05), as indicated by the variance analysis of population means for the pretreatment and subsequent during-treatment scans. Conclusions: Prone positioning stabilizes breathing patterns in most subjects investigated in this study. Importantly, a parallel analysis of the same group of patients revealed a tendency towards increasing motion amplitude of tumor targets in prone position regardless of their size or location; thus, the choice for body positioning during radiation therapy will have to consider the clinical relevance of the two opposing trends - breathing consistency and motion amplitude.« less
Howland, Jonathan; Rohsenow, Damaris J; Greece, Jacey A; Littlefield, Caroline A; Almeida, Alissa; Heeren, Timothy; Winter, Michael; Bliss, Caleb A.; Hunt, Sarah; Hermos, John
2010-01-01
Aim To assess the effects of binge drinking on students’ next-day academic test-taking performance. Design A placebo-controlled cross-over design with randomly assigned order of conditions. Participants were randomized to either alcoholic beverage (mean =.12 g% breath alcohol concentration [BrAC]) or placebo on the first night and then received the other beverage a week later. The next day, participants were assessed on test-taking, neurocognitive performance and mood state. Participants 193 college students (≥ 21 years) recruited from greater Boston. Setting The trial was conducted at the General Clinical Research Center at the Boston Medical Center. Measurements The Graduate Record Exams © (GREs) and a quiz on a lecture presented the previous day measured test-taking performance; the Neurobehavioral Evaluation System (NES3) and the Psychomotor Vigilance Test (PVT) measured neurocognitive performance; and, the Profile of Mood States (POMS) measured mood. Findings Test-taking performance was not affected the morning after alcohol administration, but mood state and attention/reaction time were. Conclusion Drinking to a level of .12 g% BrAC does not affect next-day test-taking performance, but does affect some neurocognitive measures and mood state. PMID:20403018
Matsumoto, Kenjiro; Kimura, Hiroshi; Tashima, Kimihito; Uchida, Masayuki; Horie, Syunji
2008-10-01
Several methods are used to evaluate gastric motility in rodents, but they all have technical limitations. Recent technical developments enable a convenient method to evaluate gastric motility. The (13)C-acetic acid breath test in rodents is a non-invasive and repeatable method that can be used without physical restraints. The present study aimed to validate the (13)C-acetic acid breath test by measuring the effects of loperamide, morphine, mosapride, and itopride on gastric emptying in mice. Loperamide (1-10 mg/kg) and morphine (1.25-10 mg/kg) slowed gastric emptying and decreased the maximum concentration (C(max)) and area under the curve (AUC(90 min)) value in a dose-dependent manner. Mosapride (0.2-5 mg/kg) accelerated gastric emptying and increased C(max) value. Mosapride (20 mg/kg) did not accelerate gastric emptying on the (13)C-breath test. Itopride (30 mg/kg, per os) significantly accelerated gastric emptying compared with the vehicle group. In a comparison with the conventional phenol red test, there was a correlation between the C(max) value of breath test and gastric emptying (%) of phenol red tests in treatment with loperamide or mosapride. These results indicate that the (13)C-acetic acid breath test is an accurate, noninvasive, and simple method for monitoring gastric emptying in mice. This method is useful to assess the effect of drugs and gut function pharmacologically.
The CO₂ GAP Project--CO₂ GAP as a prognostic tool in emergency departments.
Shetty, Amith L; Lai, Kevin H; Byth, Karen
2010-12-01
To determine whether CO₂ GAP [(a-ET) PCO₂] value differs consistently in patients presenting with shortness of breath to the ED requiring ventilatory support. To determine a cut-off value of CO₂ GAP, which is consistently associated with measured outcome and to compare its performance against other derived variables. This prospective observational study was conducted in ED on a convenience sample of 412 from 759 patients who underwent concurrent arterial blood gas and ETCO₂ (end-tidal CO₂) measurement. They were randomized to test sample of 312 patients and validation set of 100 patients. The primary outcome of interest was the need for ventilatory support and secondary outcomes were admission to high dependency unit or death during stay in ED. The randomly selected training set was used to select cut-points for the possible predictors; that is, CO₂ GAP, CO₂ gradient, physiologic dead space and A-a gradient. The sensitivity, specificity and predictive values of these predictors were validated in the test set of 100 patients. Analysis of the receiver operating characteristic curves revealed the CO₂ GAP performed significantly better than the arterial-alveolar gradient in patients requiring ventilator support (area under the curve 0.950 vs 0.726). A CO₂ GAP ≥10 was associated with assisted ventilation outcomes when applied to the validation test set (100% sensitivity 70% specificity). The CO₂ GAP [(a-ET) PCO₂] differs significantly in patients requiring assisted ventilation when presenting with shortness of breath to EDs and further research addressing the prognostic value of CO₂ GAP in this specific aspect is required. © 2010 The Authors. EMA © 2010 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Vocal warm-up and breathing training for teachers: randomized clinical trial
Pereira, Lílian Paternostro de Pina; Masson, Maria Lúcia Vaz; Carvalho, Fernando Martins
2015-01-01
OBJECTIVE To compare the effectiveness of two speech therapy interventions, vocal warm-up and breathing training, focusing on teachers’ voice quality. METHODS A single-blind, randomized, parallel clinical trial was conducted. The research included 31 20 to 60-year old teachers from a public school in Salvador, BA, Northeasatern Brazil, with minimum workloads of 20 hours a week, who have or have not reported having vocal alterations. The exclusion criteria were the following: being a smoker, excessive alcohol consumption, receiving additional speech therapy assistance while taking part in the study, being affected by upper respiratory tract infections, professional use of the voice in another activity, neurological disorders, and history of cardiopulmonary pathologies. The subjects were distributed through simple randomization in groups vocal warm-up (n = 14) and breathing training (n = 17). The teachers’ voice quality was subjectively evaluated through the Voice Handicap Index (Índice de Desvantagem Vocal, in the Brazilian version) and computerized voice analysis (average fundamental frequency, jitter, shimmer, noise, and glottal-to-noise excitation ratio) by speech therapists. RESULTS Before the interventions, the groups were similar regarding sociodemographic characteristics, teaching activities, and vocal quality. The variations before and after the intervention in self-assessment and acoustic voice indicators have not significantly differed between the groups. In the comparison between groups before and after the six-week interventions, significant reductions in the Voice Handicap Index of subjects in both groups were observed, as wells as reduced average fundamental frequencies in the vocal warm-up group and increased shimmer in the breathing training group. Subjects from the vocal warm-up group reported speaking more easily and having their voices more improved in a general way as compared to the breathing training group. CONCLUSIONS Both interventions were similar regarding their effects on the teachers’ voice quality. However, each contribution has individually contributed to improve the teachers’ voice quality, especially the vocal warm-up. PMID:26465664
El-beleidy, Ahmed Saad El-din; Khattab, Asser Abd EL-Hamied; El-Sherbini, Seham Awad; Al-gebaly, Hebatalla Fadel
2013-01-01
Background. Automatic tube compensation (ATC) has been developed to overcome the imposed work of breathing due to artificial airways during spontaneous breathing trials (SBTs). Objectives. This study aimed to assess extubation outcome after an SBT (spontaneous breathing trial) with ATC compared with pressure support ventilation (PSV) and to determine the risk factors for extubation failure. Methods. Patients ready for extubation were randomly assigned to two-hour spontaneous breathing trial with either ATC or pressure support ventilation. Results. In the ATC group (n = 17), 11 (65%) patients passed the SBT with subsequent extubation failure (9%). While in PSV group (n = 19), 10 (53%) patients passed the SBT with subsequent extubation failure (10%). This represented a positive predictive value for ATC of 91% and PSV of 90% (P = 0.52). Five (83%) of the patients who failed the SBT in ATC group were reintubated. This represented a higher negative predictive value for ATC of 83% than for PSV which was 56%. None of the assessed risk factors were independently associated with extubation failure including failed trial. Conclusion. ATC was equivalent to PSV in predicting patients with successful extubation. A trial failure in ATC group is associated with but does not definitely predict extubation failure. PMID:23533800
Sanaka, Masaki; Yamamoto, Takatsugu; Ishii, Tarou; Kuyama, Yasushi
2004-01-01
In pharmacokinetics, the Wagner-Nelson (W-N) method can accurately estimate the rate of drug absorption from its urinary elimination rate. A stable isotope (13C) breath test attempts to estimate the rate of absorption of 13C, as an index of gastric emptying rate, from the rate of pulmonary elimination of 13CO2. The time-gastric emptying curve determined by the breath test is quite different from that determined by scintigraphy or ultrasonography. In this report, we have shown that the W-N method can adjust the difference. The W-N equation to estimate gastric emptying from breath data is as follows: the fractional cumulative amount of gastric contents emptied by time t = Abreath (t)/Abreath (infinity) + (1/0.65).d[Abreath (t)/Abreath (infinity) ]/dt, where Abreath (t) = the cumulative recovery of 13CO2 in breath by time t and Abreath ( infinity ) = the ultimate cumulative 13CO2 recovery. The emptying flow curve generated by ultrasonography was compared with that generated by the W-N method-adjusted breath test in 6 volunteers. The emptying curves by the W-N method were almost identical to those by ultrasound. The W-N method can generate an accurate emptying flow curve from 13CO2 data, and it can adjust the difference between ultrasonography and the breath test. Copyright 2004 S. Karger AG, Basel
Optoacoustic 13C-breath test analyzer
NASA Astrophysics Data System (ADS)
Harde, Hermann; Helmrich, Günther; Wolff, Marcus
2010-02-01
The composition and concentration of exhaled volatile gases reflects the physical ability of a patient. Therefore, a breath analysis allows to recognize an infectious disease in an organ or even to identify a tumor. One of the most prominent breath tests is the 13C-urea-breath test, applied to ascertain the presence of the bacterium helicobacter pylori in the stomach wall as an indication of a gastric ulcer. In this contribution we present a new optical analyzer that employs a compact and simple set-up based on photoacoustic spectroscopy. It consists of two identical photoacoustic cells containing two breath samples, one taken before and one after capturing an isotope-marked substrate, where the most common isotope 12C is replaced to a large extent by 13C. The analyzer measures simultaneously the relative CO2 isotopologue concentrations in both samples by exciting the molecules on specially selected absorption lines with a semiconductor laser operating at a wavelength of 2.744 μm. For a reliable diagnosis changes of the 13CO2 concentration of 1% in the exhaled breath have to be detected at a concentration level of this isotope in the breath of about 500 ppm.
Validation of a new mixing chamber system for breath-by-breath indirect calorimetry.
Kim, Do-Yeon; Robergs, Robert Andrew
2012-02-01
Limited validation research exists for applications of breath-by-breath systems of expired gas analysis indirect calorimetry (EGAIC) during exercise. We developed improved hardware and software for breath-by-breath indirect calorimetry (NEW) and validated this system as well as a commercial system (COM) against 2 methods: (i) mechanical ventilation with known calibration gas, and (ii) human subjects testing for 5 min each at rest and cycle ergometer exercise at 100 and 175 W. Mechanical calibration consisted of medical grade and certified calibration gas ((4.95% CO(2), 12.01% O(2), balance N(2)), room air (20.95% O(2), 0.03% CO(2), balance N(2)), and 100% nitrogen), and an air flow turbine calibrated with a 3-L calibration syringe. Ventilation was mimicked manually using complete 3-L calibration syringe manouvers at a rate of 10·min(-1) from a Douglas bag reservoir of calibration gas. The testing of human subjects was completed in a counterbalanced sequence based on 5 repeated tests of all conditions for a single subject. Rest periods of 5 and 10 min followed the 100 and 175 W conditions, respectively. COM and NEW had similar accuracy when tested with known ventilation and gas fractions. However, during human subjects testing COM significantly under-measured carbon dioxide gas fractions, over-measured oxygen gas fractions and minute ventilation, and resulted in errors to each of oxygen uptake, carbon dioxide output, and respiratory exchange ratio. These discrepant findings reveal that controlled ventilation and gas fractions are insufficient to validate breath-by-breath, and perhaps even time-averaged, systems of EGAIC. The errors of the COM system reveal the need for concern over the validity of commercial systems of EGAIC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zellars, Richard, E-mail: zellari@jhmi.edu; Bravo, Paco E.; Tryggestad, Erik
2014-03-15
Purpose: Cardiac muscle perfusion, as determined by single-photon emission computed tomography (SPECT), decreases after breast and/or chest wall (BCW) irradiation. The active breathing coordinator (ABC) enables radiation delivery when the BCW is farther from the heart, thereby decreasing cardiac exposure. We hypothesized that ABC would prevent radiation-induced cardiac toxicity and conducted a randomized controlled trial evaluating myocardial perfusion changes after radiation for left-sided breast cancer with or without ABC. Methods and Materials: Stages I to III left breast cancer patients requiring adjuvant radiation therapy (XRT) were randomized to ABC or No-ABC. Myocardial perfusion was evaluated by SPECT scans (before andmore » 6 months after BCW radiation) using 2 methods: (1) fully automated quantitative polar mapping; and (2) semiquantitative visual assessment. The left ventricle was divided into 20 segments for the polar map and 17 segments for the visual method. Segments were grouped by anatomical rings (apical, mid, basal) or by coronary artery distribution. For the visual method, 2 nuclear medicine physicians, blinded to treatment groups, scored each segment's perfusion. Scores were analyzed with nonparametric tests and linear regression. Results: Between 2006 and 2010, 57 patients were enrolled and 43 were available for analysis. The cohorts were well matched. The apical and left anterior descending coronary artery segments had significant decreases in perfusion on SPECT scans in both ABC and No-ABC cohorts. In unadjusted and adjusted analyses, controlling for pretreatment perfusion score, age, and chemotherapy, ABC was not significantly associated with prevention of perfusion deficits. Conclusions: In this randomized controlled trial, ABC does not appear to prevent radiation-induced cardiac perfusion deficits.« less
Braden, B; Braden, C P; Klutz, M; Lembcke, B
1993-04-01
Breath hydrogen (H2) analysis, as used in gastroenterologic function tests, requires a stationary analysis system equipped with a gaschromatograph or an electrochemical sensor cell. Now a portable breath H2-analyzer has been miniaturized to pocket size (104 mm x 62 mm x 29 mm). The application of this device in clinical practice has been assessed in comparison to the standard GMI-exhaled monitor. The pocket analyzer showed a linear response to standards with H2-concentrations ranging from 0-100 ppm (n = 7), which was not different from the GMI-apparatus. The correlation of both methods during clinical application (lactose tolerance tests, mouth-to-coecum transit time determined with lactulose) was excellent (Y = 1.08 X + 0.96; r = 0.959). Using the new device, both, analysis (3 s vs. 90 s) and the reset-time (43 s vs. 140 s) were shorter whereas calibration was more feasible with the GMI-apparatus. It is concluded, that the considerably cheaper pocket-sized breath H2-analyzer is as precise and sensitive as the GMI-exhaled monitor, and thus presents a valid alternative for H2-breath tests.
Hatley, Ross Hm; Byrne, Sarah M
2017-01-01
To improve convenience to patients, there have been advances in the operation of nebulizers, resulting in fast treatment times and less drug lost to the environment. However, limited attention has been paid to the effects of these developments on the delivered dose (DD) and respirable delivered dose (RDD). Published pharmacopoeia and ISO testing guidelines for adult-use testing utilize a single breathing pattern, which may not be sufficient to enable effective comparisons between the devices. The DD of 5 mg of salbutamol sulfate into adult breathing patterns with inhalation:exhalation (I:E) ratios between 1:1 and 1:4 was determined. Droplet size was determined by laser diffraction and RDD calculated. Nine different nebulizer brands with different modes of operation (conventional, venturi, breath-enhanced, mesh, and breath-activated) were tested. Between the non-breath-activated nebulizers, a 2.5-fold difference in DD (~750-1,900 µg salbutamol) was found; with RDD, there was a more than fourfold difference (~210-980 µg). With increasing time spent on exhalation, there were progressive reductions in DD and RDD, with the RDD at an I:E ratio of 1:4 being as little as 40% of the dose with the 1:1 I:E ratio. The DD and RDD from the breath-activated mesh nebulizer were independent of the I:E ratio, and for the breath-activated jet nebulizer, there was less than 20% change in RDD between the I:E ratios of 1:1 and 1:4. Comparing nebulizers using the I:E ratio recommended in the guidelines does not predict relative performance between the devices at other ratios. There was significant variance in DD or RDD between different brands of non-breath-activated nebulizer. In future, consideration should be given to revision of the test protocols included in the guidelines, to reflect more accurately the potential therapeutic dose that is delivered to a realistic spectrum of breathing patterns.
Khng, Kiat Hui
2017-11-01
A pre-test/post-test, intervention-versus-control experimental design was used to examine the effects, mechanisms and moderators of deep breathing on state anxiety and test performance in 122 Primary 5 students. Taking deep breaths before a timed math test significantly reduced self-reported feelings of anxiety and improved test performance. There was a statistical trend towards greater effectiveness in reducing state anxiety for boys compared to girls, and in enhancing test performance for students with higher autonomic reactivity in test-like situations. The latter moderation was significant when comparing high-versus-low autonomic reactivity groups. Mediation analyses suggest that deep breathing reduces state anxiety in test-like situations, creating a better state-of-mind by enhancing the regulation of adaptive-maladaptive thoughts during the test, allowing for better performance. The quick and simple technique can be easily learnt and effectively applied by most children to immediately alleviate some of the adverse effects of test anxiety on psychological well-being and academic performance.
Cross, Russell; Olivieri, Laura; O'Brien, Kendall; Kellman, Peter; Xue, Hui; Hansen, Michael
2016-02-25
Traditional cine imaging for cardiac functional assessment requires breath-holding, which can be problematic in some situations. Free-breathing techniques have relied on multiple averages or real-time imaging, producing images that can be spatially and/or temporally blurred. To overcome this, methods have been developed to acquire real-time images over multiple cardiac cycles, which are subsequently motion corrected and reformatted to yield a single image series displaying one cardiac cycle with high temporal and spatial resolution. Application of these algorithms has required significant additional reconstruction time. The use of distributed computing was recently proposed as a way to improve clinical workflow with such algorithms. In this study, we have deployed a distributed computing version of motion corrected re-binning reconstruction for free-breathing evaluation of cardiac function. Twenty five patients and 25 volunteers underwent cardiovascular magnetic resonance (CMR) for evaluation of left ventricular end-systolic volume (ESV), end-diastolic volume (EDV), and end-diastolic mass. Measurements using motion corrected re-binning were compared to those using breath-held SSFP and to free-breathing SSFP with multiple averages, and were performed by two independent observers. Pearson correlation coefficients and Bland-Altman plots tested agreement across techniques. Concordance correlation coefficient and Bland-Altman analysis tested inter-observer variability. Total scan plus reconstruction times were tested for significant differences using paired t-test. Measured volumes and mass obtained by motion corrected re-binning and by averaged free-breathing SSFP compared favorably to those obtained by breath-held SSFP (r = 0.9863/0.9813 for EDV, 0.9550/0.9685 for ESV, 0.9952/0.9771 for mass). Inter-observer variability was good with concordance correlation coefficients between observers across all acquisition types suggesting substantial agreement. Both motion corrected re-binning and averaged free-breathing SSFP acquisition and reconstruction times were shorter than breath-held SSFP techniques (p < 0.0001). On average, motion corrected re-binning required 3 min less than breath-held SSFP imaging, a 37% reduction in acquisition and reconstruction time. The motion corrected re-binning image reconstruction technique provides robust cardiac imaging that can be used for quantification that compares favorably to breath-held SSFP as well as multiple average free-breathing SSFP, but can be obtained in a fraction of the time when using cloud-based distributed computing reconstruction.
JOHNSON, MARK B.; VOAS, ROBERT B.; KELLEY-BAKER, TARA; FURR-HOLDEN, C. DEBRA M.
2009-01-01
Objective We examined the effect of providing drinkers with blood alcohol concentration (BAC) information on subjective assessments of alcohol impairment and drunk-driving risk. Method We sampled 959 drinking participants from a natural drinking environment and asked them to self-administer a personal saliva-based alcohol test. Participants then were asked to rate their alcohol impairment and to indicate whether they could drive legally under one of four BAC feedback conditions (assigned at random): (1) control condition (no BAC feedback provided before the ratings); (2) categorical BAC information (low, high, and highest risk) from the saliva test; (3) categorical BAC information corroborated by a calibrated police breath alcohol analyzer; and (4) precise (three-digit) BAC information from the breath alcohol analyzer. Results Both control participants and participants who received precise BAC feedback gave subjective impairment ratings that correlated with actual BACs. For participants who received categorical BAC information from the saliva test, subjective impairment did not correlate with the actual BAC. Providing drinkers with BAC information, however, did help them predict more accurately if their BAC was higher than the legal BAC driving limit. Conclusions Although BAC information can influence drinkers’ assessments of alcohol impairment and drunk-driving risk, there is no strong evidence that personal saliva-based alcohol tests are particularly useful. PMID:18612570
Seo, KyoChul; Hwan, Park Seung; Park, KwangYong
2017-03-01
[Purpose] The purpose of this study is to examine the effects of inspiratory diaphragm breathing exercise and expiratory pursed-lip breathing exercise on chronic stroke patients' respiratory muscle activation. [Subjects and Methods] All experimental subjects performed exercises five times per week for four weeks. Thirty chronic stroke patients were randomly assign to an experimental group of 15 patients and a control group of 15 patients. The experimental group underwent exercises consisting of basic exercise treatment for 15 minutes and inspiratory diaphragm breathing exercise and expiratory pursed-lip breathing exercise for 15 minutes and the control group underwent exercises consisting of basic exercise treatment for 15 minutes and auto-med exercise for 15 minutes. The activation levels of respiratory muscles were measured before and after the experiment using MP 150WSW to obtain the results of the experiment. [Results] In the present study, when the pulmonary functions of the experimental group and the control group before and after the experiment were compared, whereas the experimental group showed significant differences in all sections. In the verification of intergroup differences between the experimental group and the control group before and after the experiment. [Conclusion] The respiratory rehabilitation exercise is considered to be capable of inducing positive effects on stroke patients' respiratory muscles through diaphragm breathing exercise and lip puckering breathing exercise.
Cardiorespiratory interactions during resistive load breathing.
Calabrese, P; Perrault, H; Dinh, T P; Eberhard, A; Benchetrit, G
2000-12-01
The addition to the respiratory system of a resistive load results in breathing pattern changes and in negative intrathoracic pressure increases. The aim of this study was to use resistive load breathing as a stimulus to the cardiorespiratory interaction and to examine the extent of the changes in heart rate variability (HRV) and respiratory sinus arrhythmia (RSA) in relation to the breathing pattern changes. HRV and RSA were studied in seven healthy subjects where four resistive loads were applied in a random order during the breath and 8-min recording made in each condition. The HRV spectral power components were computed from the R-R interval sequences, and the RSA amplitude and phase were computed from the sinusoid fitting the instantaneous heart rate within each breath. Adding resistive loads resulted in 1) increasing respiratory period, 2) unchanging heart rate, and 3) increasing HRV and changing RSA characteristics. HRV and RSA characteristics are linearly correlated to the respiratory period. These modifications appear to be linked to load-induced changes in the respiratory period in each individual, because HRV and RSA characteristics are similar at a respiratory period obtained either by loading or by imposed frequency breathing. The present results are discussed with regard to the importance of the breathing cycle duration in these cardiorespiratory interactions, suggesting that these interactions may depend on the time necessary for activation and dissipation of neurotransmitters involved in RSA.
Significance of hydrogen breath tests in children with suspected carbohydrate malabsorption
2014-01-01
Background Hydrogen breath tests are noninvasive procedures frequently applied in the diagnostic workup of functional gastrointestinal disorders. Here, we review hydrogen breath test results and the occurrence of lactose, fructose and sorbitol malabsorption in pediatric patients; and determine the significance of the findings and the outcome of patients with carbohydrate malabsorption. Methods We included 206 children (88 male, 118 female, median age 10.7 years, range 3–18 years) with a total of 449 hydrogen breath tests (lactose, n = 161; fructose, n = 142; sorbitol, n = 146) into a retrospective analysis. Apart from test results, we documented symptoms, the therapeutic consequences of the test, the outcome and the overall satisfaction of the patients and families. Results In total, 204 (46%) of all breath tests were positive. Long-term follow-up data could be collected from 118 patients. Of 79 patients (67%) who were put on a diet reduced in lactose, fructose and/or sorbitol, the majority (92%, n = 73) reported the diet to be strict and only 13% (n = 10) had no response to diet. Most families (96%, n = 113) were satisfied by the test and the therapy. There were only 21 tests (5%) with a borderline result because the criteria for a positive result were only partially met. Conclusions Hydrogen breath tests can be helpful in the evaluation of children with gastrointestinal symptoms including functional intestinal disorders. If applied for a variety of carbohydrates but only where indicated, around two-third of all children have positive results. The therapeutic consequences are successfully relieving symptoms in the vast majority of patients. PMID:24575947
Ulrich, Silvia; Hasler, Elisabeth D; Saxer, Stéphanie; Furian, Michael; Müller-Mottet, Séverine; Keusch, Stephan; Bloch, Konrad E
2017-04-14
The purpose of the current trial was to test the hypothesis that breathing oxygen-enriched air increases exercise performance of patients with pulmonary arterial or chronic thrombo-embolic pulmonary hypertension (PAH/CTEPH) and to investigate involved mechanisms. Twenty-two patients with PAH/CTEPH, eight women, means ± SD 61 ± 14 years, resting mPAP 35 ± 9mmHg, PaO2 ambient air >7.3 kPa, underwent four bicycle ergospirometries to exhaustion on different days, while breathing oxygen-enriched (FiO2 0.50, hyperoxia) or ambient air (FiO2 0.21, normoxia) using progressively increased or constant load protocols (with 75% maximal work rate under FiO2 0.21), according to a randomized, sham-controlled, single-blind, cross-over design. ECG, pulmonary gas-exchange, arterial blood gases, cerebral and quadriceps muscle tissue oxygenation (CTO and QMTO) by near-infrared spectroscopy were measured. In ramp exercise, maximal work rate increased from 113 ± 38 W with normoxia to 132 ± 48 W with hyperoxia, mean difference 19.7 (95% CI 10.5-28.9) W, P < 0.001. Constant load exercise endurance increased from 571 ± 443 to 1242 ± 514 s, mean difference 671 (95% CI 392-951) s, P < 0.001. At end-exercise with hyperoxia PaO2, CTO, QMTO, and PaCO2 were increased, and ventilatory equivalents for CO2 were reduced while the physiological dead space/tidal volume ratio remained unchanged. In patients with PAH/CTEPH, breathing oxygen-enriched air provides major increases in exercise performance. This is related to an improved arterial oxygenation that promotes oxygen availability in muscles and brain and to a reduction of the excessive ventilatory response to exercise thereby enhancing ventilatory efficiency. Patients with PAH/CTEPH may therefore benefit from oxygen therapy during daily physical activities and training. clinicaltrials.gov Identifier: NCT01748474. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Imposed Power of Breathing Associated With Use of an Impedance Threshold Device
2007-02-01
threshold device and a sham impedance threshold device. DESIGN: Prospective randomized blinded protocol. SETTING: University medical center. PATIENTS...for males). METHODS: The volunteers completed 2 trials of breathing through a face mask fitted with an active impedance threshold device set to open...at -7cmH 2 O pressure, or with a sham impedance threshold device, which was identical to the active device except that it did not contain an
Hammer, Veronika; Hammer, Katharina; Memaran, Nima; Huber, Wolf-Dietrich; Hammer, Karin; Hammer, Johann
2018-05-01
Limited valid data are available regarding the association of fructose-induced symptoms, fructose malabsorption, and clinical symptoms. To develop a questionnaire for valid symptom assessment before and during a carbohydrate breath test and to correlate symptoms with fructose breath test results in children/adolescents with functional abdominal pain. A Likert-type questionnaire assessing symptoms considered relevant for hydrogen breath test in children was developed and underwent initial validation. Fructose malabsorption was determined by increased breath hydrogen in 82 pediatric patients with functional abdominal pain disorders; fructose-induced symptoms were quantified by symptom score ≥2 and relevant symptom increase over baseline. The results were correlated with clinical symptoms. The time course of symptoms during the breath test was assessed. The questionnaire exhibited good psychometric properties in a standardized assessment of the severity of carbohydrate-related symptoms. A total of 40 % (n = 33) had malabsorption; symptoms were induced in 38 % (n = 31), but only 46 % (n = 15) with malabsorption were symptomatic. There was no significant correlation between fructose malabsorption and fructose-induced symptoms. Clinical symptoms correlated with symptoms evoked during the breath test (p < 0.001, r 2 = 0.21) but not with malabsorption (NS). Malabsorbers did not differ from non-malabsorbers in terms of symptoms during breath test. Symptomatic patients had significantly higher pain and flatulence scores over the 9-h observation period (p < 0.01) than did nonsymptomatic patients; the meteorism score was higher after 90 min. Fructose-induced symptoms but not fructose malabsorption are related to increased abdominal symptoms and have distinct timing patterns.
Cost-effectiveness of interventions to prevent alcohol-related disease and injury in Australia.
Cobiac, Linda; Vos, Theo; Doran, Christopher; Wallace, Angela
2009-10-01
To evaluate cost-effectiveness of eight interventions for reducing alcohol-attributable harm and determine the optimal intervention mix. Interventions include volumetric taxation, advertising bans, an increase in minimum legal drinking age, licensing controls on operating hours, brief intervention (with and without general practitioner telemarketing and support), drink driving campaigns, random breath testing and residential treatment for alcohol dependence (with and without naltrexone). Cost-effectiveness is modelled over the life-time of the Australian population in 2003, with all costs and health outcomes evaluated from an Australian health sector perspective. Each intervention is compared with current practice, and the most cost-effective options are then combined to determine the optimal intervention mix. Cost-effectiveness is measured in 2003 Australian dollars per disability adjusted life year averted. Although current alcohol intervention in Australia (random breath testing) is cost-effective, if the current spending of $71 million could be invested in a more cost-effective combination of interventions, more than 10 times the amount of health gain could be achieved. Taken as a package of interventions, all seven preventive interventions would be a cost-effective investment that could lead to substantial improvement in population health; only residential treatment is not cost-effective. Based on current evidence, interventions to reduce harm from alcohol are highly recommended. The potential reduction in costs of treating alcohol-related diseases and injuries mean that substantial improvements in population health can be achieved at a relatively low cost to the health sector. © 2009 The Authors. Journal compilation © 2009 Society for the Study of Addiction.
... such as Riley-Day syndrome or Rett syndrome Iron deficiency anemia A family history of breath holding spells ( ... tests may be done to check for an iron deficiency. Other tests that may be done include: EKG ...
The likelihood of acetone interference in breath alcohol measurement
DOT National Transportation Integrated Search
1985-09-01
This report discusses the significance of possible interference of acetone in breath alcohol testing. The following dimensions were considered: 1) what levels of acetone concentration may appear on the breath; 2) what levels of acetone concentration ...
Conti, Giorgio; Gregoretti, Cesare; Spinazzola, Giorgia; Festa, Olimpia; Ferrone, Giuliano; Cipriani, Flora; Rossi, Marco; Piastra, Marco; Costa, Roberta
2015-04-01
In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive respiratory conditions. A test lung, connected to a pediatric mannequin using different interfaces (endotracheal tube [ETT], face mask, and helmet), was ventilated in pressure support ventilation mode testing 2 ventilator settings (pressurization time [Timepress]50%/cycling-off flow threshold [Trexp]25%, Timepress80%/Trexp60%), randomly applied. The test lung was set to simulate one pediatric patient with a healthy respiratory system and another with a mixed obstructive and restricted respiratory condition, at different breathing frequencies (f) (30, 40, and 50 breaths/min). We measured inspiratory trigger delay, pressurization time, expiratory trigger delay, and time of synchrony. At each breathing frequency, the helmet showed the longest inspiratory trigger delay compared with the ETT and face mask. At f30, the ETT had a reduced Tpress. The helmet had the shortest Tpress in the simulated child with a mixed obstructive and restricted respiratory condition, at f40 during Timepress50%/Trexp25% and at f50 during Timepress80%/Trexp60%. In the simulated child with a normal respiratory condition, the ETT presented the shortest Tpress value at f50 during Timepress80%/Trexp60%. Concerning the expiratory trigger delay, the helmet showed the best interaction at f30, but the worst at f40 and at f50. The helmet showed the shortest time of synchrony during all ventilator settings. The choice of the interface can influence patient-ventilator synchrony in a pediatric model breathing at increased f, thus making it more difficult to set the ventilator, particularly during noninvasive ventilation. The helmet demonstrated the worst interaction, suggesting that the face mask should be considered as the first choice for delivering noninvasive ventilation in a pediatric model. Copyright © 2015 by Daedalus Enterprises.
Kang, Jeong-Il; Jeong, Dae-Keun; Choi, Hyun
2016-01-01
[Purpose] Fragmentary studies on characteristics of respiratory muscles are being done to increase respiratory capacity by classifying exercises into voluntary respiratory exercise which relieves symptoms and prevents COPD and exercise using breathing exercise equipment. But this study found changes on respiratory pattern through changes on the activity pattern of agonist and synergist respiratory muscles and studied what effect they can have on body function improvement. [Subjects and Methods] Fifteen subjects in experimental group I that respiratory exercise of diaphragm and 15 subjects in experimental group II that feedback respiratory exercise were randomly selected among COPD patients to find the effective intervention method for COPD patients. And intervention program was conducted for 5 weeks, three times a week, once a day and 30 minutes a session. They were measured with BODE index using respiratory muscle activity, pulmonary function, the six-minute walking test, dyspnea criteria and BMI Then the results obtained were compared and analyzed. [Results] There was a significant difference in sternocleidomastoid muscle and scalene muscle and in 6-minute walk and BODE index for body function. Thus the group performing feedback respiratory had more effective results for mild COPD patients. [Conclusion] Therefore, the improvement was significant regarding the activity of respiratory muscles synergists when breathing before doing breathing exercise. Although, it is valuable to reduce too much mobilization of respiratory muscles synergists through the proper intervention it is necessary to study body function regarding improvement of respiratory function for patients with COPD.
Smith, Joshua R; Kurti, Stephanie P; Johnson, Ariel M; Kolmer, Sarah A; Harms, Craig
2015-12-01
The purpose of this study was to determine if the amount of physical activity influences airway sensitivity and bronchodilation in healthy subjects across a range of physical activity levels. Thirty healthy subjects (age, 21.9 ± 2.6 years; 13 men/17 women) with normal pulmonary function reported to the laboratory on 2 separate occasions where they were randomized to breathe either hypertonic saline (HS) (nebulized hypertonic saline (25%) for 20 min) or HS followed by 5 deep inspirations (DIs), which has been reported to bronchodilate the airways. Pulmonary function tests (PFTs) were performed prior to both conditions and following the HS breathing or 5 DIs. Moderate to vigorous physical activity (MVPA) level was measured via accelerometer worn for 7 days. Following the HS breathing, forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) significantly decreased from baseline by -11.8% ± 8.4% and -9.3% ± 6.7%, respectively. A 2-segment linear model determined significant relationships between MVPA and percent change in FEV1 (r = 0.50) and FVC (r = 0.55). MVPA above ∼497 and ∼500 min/week for FEV1 and FVC, respectively, resulted in minor additional improvements (p > 0.05) in PFTs following the HS breathing. Following the DIs, FEV1 and FVC decreased (p < 0.05) by -7.3% ± 8.6% and -5.7% ± 5.7%, respectively, from baseline, but were not related (p > 0.05) to MVPA. In conclusion, these data demonstrate that higher MVPA levels attenuated airway sensitivity but not bronchodilation in healthy subjects.
32 CFR 634.8 - Implied consent.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to blood, breath, or urine tests. Persons who drive on the installation shall be deemed to have given their consent to evidential tests for alcohol or other drug content of their blood, breath, or urine...
Enzyme induction in neonates after fetal exposure to antiepileptic drugs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rating, D.; Jaeger-Roman, E.; Nau, H.
1983-01-01
The /sup 13/C-AP breath test is shown to be a convenient, noninvasive method to monitor velocity and capacity of P450-dependent AP N-demethylation in infancy and childhood. According to /sup 13/C-AP breath tests, neonates have a very low capacity to eliminate /sup 13/CO/sub 2/, which is only 15 to 21% of the activity in adults. During the first year of life AP N-demethylation increases to reach its maximum at about 2 years; afterwards a slight decrease occurs. In 25 neonates exposed prenatally to different antiepileptic drugs /sup 13/C-AP breath test was efficiently used to prove that cytochrome AP N-demethylation was considerablymore » stimulated. After primidone/phenobarbitone, especially in combination with phenytoin, /sup 13/C elimination reaches and even surpasses the range for older children. Valproate exposure during fetal life is not consistently followed by a significant increase in AP N-demethylation. The enzyme induction demonstrated by /sup 13/C-AP breath test was often accompanied by accelerated metabolic clearance and shortened half-life times of transplacentally acquired antiepileptic drugs. There was good agreement between /sup 13/C-AP breath tests and pharmacokinetic data for primidone/phenobarbitone but not for phenytoin. In contrast, in the case of phenytoin exposure during pregnancy the pharmacokinetic parameters and the /sup 13/C breath test data will transport very different informations about enzyme induction in these neonates.« less
Giardino, Nicholas D; Curtis, Jeffrey L; Andrei, Adin-Cristian; Fan, Vincent S; Benditt, Joshua O; Lyubkin, Mark; Naunheim, Keith; Criner, Gerard; Make, Barry; Wise, Robert A; Murray, Susan K; Fishman, Alfred P; Sciurba, Frank C; Liberzon, Israel; Martinez, Fernando J
2010-03-09
Anxiety in patients with chronic obstructive pulmonary disease (COPD) is associated with self-reported disability. The purpose of this study is to determine whether there is an association between anxiety and functional measures, quality of life and dyspnea. Data from 1828 patients with moderate to severe emphysema enrolled in the National Emphysema Treatment Trial (NETT), collected prior to rehabilitation and randomization, were used in linear regression models to test the association between anxiety symptoms, measured by the Spielberger State Trait Anxiety Inventory (STAI) and: (a) six-minute walk distance test (6 MWD), (b) cycle ergometry peak workload, (c) St. Georges Respiratory Questionnaire (SRGQ), and (d) UCSD Shortness of Breath Questionnaire (SOBQ), after controlling for potential confounders including age, gender, FEV1 (% predicted), DLCO (% predicted), and the Beck Depression Inventory (BDI). Anxiety was significantly associated with worse functional capacity [6 MWD (B = -0.944, p < .001), ergometry peak workload (B = -.087, p = .04)], quality of life (B = .172, p < .001) and shortness of breath (B = .180, p < .001). Regression coefficients show that a 10 point increase in anxiety score is associated with a mean decrease in 6 MWD of 9 meters, a 1 Watt decrease in peak exercise workload, and an increase of almost 2 points on both the SGRQ and SOBQ. In clinically stable patients with moderate to severe emphysema, anxiety is associated with worse exercise performance, quality of life and shortness of breath, after accounting for the influence of demographic and physiologic factors known to affect these outcomes. ClinicalTrials.gov NCT00000606.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 1 2011-10-01 2011-10-01 false What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD? 40.243 Section 40.243 Transportation Office of the...-evidential breath ASD? As the BAT or STT, you must take the following steps: (a) Select, or allow the...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD? 40.243 Section 40.243 Transportation Office of the...-evidential breath ASD? As the BAT or STT, you must take the following steps: (a) Select, or allow the...
Tripathi, M; Subedi, A; Raimajhi, A; Pokharel, K; Pandey, M
2013-01-01
Abdominal sepsis is associated with varied degree of hypoxemia and atelactasis in the lung and can enhance the onset of desaturation of arterial blood during apnea. This study looked at methods to improve safety margin of apnea during induction of anesthesia in these high-risk patients. It was a randomized, single blind study on adult patients presenting for emergency laparotomy due to peritonitis in a university teaching hospital setting. In group 1 (IS) (n = 32), three sessions of incentive spirometry (IS) were performed within one hour before induction of anesthesia. In group 2 (DB) (n = 34), patients were subjected to deep breathing sessions in a similar manner. All patients received preoxygenation (100%) by mask for 3 min, followed by rapid-sequence induction of anesthesia using fentanyl, thiopental, and suxamethonium and endotracheal intubation. Patients were subjected to a period of apnea by keeping the end of the endotracheal tube open to air till they developed 95% hemoglobin saturation (SpO 2) by pulse oxymetry. Positive pressure ventilation was resumed at the end. We observed for hemodynamic changes, apnea time, and SpO 2 (100%) recovery time on resuming ventilation. Arterial blood gas samples were taken before intervention, after IS or DB, after preoxygenation, and at the end of apnea. One-way analysis of variance (ANOVA), X 2 test, Kaplan-Meier graph, and log-rank tests were applied to compare the two study groups. Oxygenation level in group 1 (265 ± 76.7 mmHg) patients was significantly (P < 0.001) higher than in group 2 (221 ± 61.8 mmHg)at the end of preoxygenation. The apnea time (median: lower bound - upper bound Confidence Interval apnea time) (272:240-279 s) in group 1 (IS) patients was significantly higher P < 0.05) than in group 2 (180:163-209 s) patients. Saturation recovery time (35:34-46 s) in group 1 (IS) patients was also quicker than in group 2 patients (48:44-58 s). IS in the preoperative period is superior to deep breathing sessions for improving apnea tolerance during induction of anesthesia in abdominal sepsis patients.
Effects of homeopathic mother tinctures on breath alcohol testing.
Boatto, Gianpiero; Trignano, Claudia; Burrai, Lucia; Spanu, Andrea; Nieddu, Maria
2015-01-01
In some countries, it is illegal to drive with any detectable amount of alcohol in blood; in others, the legal limit is 0.5 g/L or lower. Recently, some defendants charged with driving under the influence of alcohol and have claimed that positive breath alcohol test results were due to the ingestion of homeopathic mother tinctures. These preparations are obtained by maceration, digestion, infusion, or decoction of herbal material in hydroalcoholic solvent. A series of tests were conducted to evaluate the alcoholic content of three homeopathic mother tinctures and their ability to produce inaccurate breath alcohol results. Nine of 30 subjects gave positive results (0.11-0.82 g/L) when tests were taken within 1 min after drinking mother tincture. All tests taken at least 15 min after the mother tincture consumption and resulted in alcohol-free readings. An observation period of 15-20 min prior to breath alcohol testing eliminates the possibility of false-positive results. © 2014 American Academy of Forensic Sciences.
Can handling E85 motor fuel cause positive breath alcohol test results?
Ran, Ran; Mullins, Michael E
2013-09-01
Hand-held breath alcohol analyzers are widely used by police in traffic stops of drivers suspected of driving while intoxicated (DWI). E85 is a motor fuel consisting of 85% ethanol and 15% gasoline or other hydrocarbons, and is available at nearly 2,600 stations in the USA. We sought to determine whether handling E85 fuel could produce measurable breath alcohol results using a hand-held analyzer and to see if this would be a plausible explanation for a positive breath alcohol test. Five healthy adult subjects dispensed or transferred 8 US gallons of E85 fuel in each of four scenarios. We measured breath alcohol concentration in g/210 L of exhaled breath using the BACTrack S50 at 0, 2, 4, 6, 8, 10, 15 and 20 min after each fuel-handling scenario. Most of the subjects had no detectable breath alcohol after handling E85 motor fuel. Transient elevations (0.02-0.04 g/210 L) in breath alcohol measurement occurred up to 6 min after handling E85 in a minority of subjects. We conclude that it is unlikely that handling E85 motor fuel would result in erroneous prosecution for DWI.
Ueta, Ikuo; Mizuguchi, Ayako; Okamoto, Mitsuyoshi; Sakamaki, Hiroyuki; Hosoe, Masahiko; Ishiguro, Motoyuki; Saito, Yoshihiro
2014-03-20
Isoprene in human breath is said to be related to cholesterol metabolism, and the possibility of the correlations with some clinical parameters has been studied. However, at this stage, no clear benefit of breath isoprene has been reported for clinical diagnosis. In this work, isoprene and acetone concentrations were measured in the breath of healthy and obese subjects using a needle-type extraction device for subsequent analysis in gas chromatography-mass spectrometry (GC-MS) to investigate the possibility of these compounds as an indicator of possible diseases. After measuring intraday and interday variations of isoprene and acetone concentrations in breath samples of healthy subjects, their concentrations were also determined in 80 healthy and 17 obese subjects. In addition, correlation between these breath concentrations and the blood tests result was studied for these healthy and obese subjects. The results indicated successful determination of breath isoprene and acetone in this work, however, no clear correlation was observed between these measured values and the blood test results. Breath isoprene concentration may not be a useful indicator for obesity or hypercholesterolemia. Copyright © 2014 Elsevier B.V. All rights reserved.
Can Handling E85 Motor Fuel Cause Positive Breath Alcohol Test Results?
Ran, Ran; Mullins, Michael E.
2013-01-01
Hand-held breath alcohol analyzers are widely used by police in traffic stops of drivers suspected of driving while intoxicated (DWI). E85 is a motor fuel consisting of 85% ethanol and 15% gasoline or other hydrocarbons, and is available at nearly 2,600 stations in the USA. We sought to determine whether handling E85 fuel could produce measurable breath alcohol results using a hand-held analyzer and to see if this would be a plausible explanation for a positive breath alcohol test. Five healthy adult subjects dispensed or transferred 8 US gallons of E85 fuel in each of four scenarios. We measured breath alcohol concentration in g/210 L of exhaled breath using the BACTrack S50 at 0, 2, 4, 6, 8, 10, 15 and 20 min after each fuel-handling scenario. Most of the subjects had no detectable breath alcohol after handling E85 motor fuel. Transient elevations (0.02–0.04 g/210 L) in breath alcohol measurement occurred up to 6 min after handling E85 in a minority of subjects. We conclude that it is unlikely that handling E85 motor fuel would result in erroneous prosecution for DWI. PMID:23843422
Rapid Point-Of-Care Breath Test for Biomarkers of Breast Cancer and Abnormal Mammograms
Phillips, Michael; Beatty, J. David; Cataneo, Renee N.; Huston, Jan; Kaplan, Peter D.; Lalisang, Roy I.; Lambin, Philippe; Lobbes, Marc B. I.; Mundada, Mayur; Pappas, Nadine; Patel, Urvish
2014-01-01
Background Previous studies have reported volatile organic compounds (VOCs) in breath as biomarkers of breast cancer and abnormal mammograms, apparently resulting from increased oxidative stress and cytochrome p450 induction. We evaluated a six-minute point-of-care breath test for VOC biomarkers in women screened for breast cancer at centers in the USA and the Netherlands. Methods 244 women had a screening mammogram (93/37 normal/abnormal) or a breast biopsy (cancer/no cancer 35/79). A mobile point-of-care system collected and concentrated breath and air VOCs for analysis with gas chromatography and surface acoustic wave detection. Chromatograms were segmented into a time series of alveolar gradients (breath minus room air). Segmental alveolar gradients were ranked as candidate biomarkers by C-statistic value (area under curve [AUC] of receiver operating characteristic [ROC] curve). Multivariate predictive algorithms were constructed employing significant biomarkers identified with multiple Monte Carlo simulations and cross validated with a leave-one-out (LOO) procedure. Results Performance of breath biomarker algorithms was determined in three groups: breast cancer on biopsy versus normal screening mammograms (81.8% sensitivity, 70.0% specificity, accuracy 79% (73% on LOO) [C-statistic value], negative predictive value 99.9%); normal versus abnormal screening mammograms (86.5% sensitivity, 66.7% specificity, accuracy 83%, 62% on LOO); and cancer versus no cancer on breast biopsy (75.8% sensitivity, 74.0% specificity, accuracy 78%, 67% on LOO). Conclusions A pilot study of a six-minute point-of-care breath test for volatile biomarkers accurately identified women with breast cancer and with abnormal mammograms. Breath testing could potentially reduce the number of needless mammograms without loss of diagnostic sensitivity. PMID:24599224
DOT National Transportation Integrated Search
1972-01-01
During its 1972 session, the General Assembly of Virginia enacted Senate Bill 104, which authorizes the breath test, as well as the blood test used previously, as a proper chemical test to determine the alcoholic content of the blood. Any person arre...
Silva, C A G; Motta, M E F A
2013-05-01
The effect of muscular training, abdominal massage and diaphragmatic breathing was compared with medical treatment in a prospective randomized trial of patients with chronic functional constipation. Patients aged 4-18 years old with functional constipation according to the Rome III criteria were randomized to physiotherapy or medical treatment. In the physiotherapy group, exercises (isometric training of the abdominal muscles, diaphragmatic breathing exercises and abdominal massage) were employed during 12 40-min sessions twice a week by a trained physiotherapist, with laxatives. Patients in the medication group were only given laxatives. Primary outcome measures were frequency of defaecation and faecal incontinence. The analysis was performed by intention-to-treat. After 6 weeks of treatment, the frequency of bowel movements was higher in the physiotherapy group [5.1 (2.1) days/week] than in the medication group [3.9 (2.0) days/week] (P = 0.01). The frequency of faecal incontinence was no different between the groups [3.6 (1.9) days/week vs 3.0 (2.1) days/week] (P = 0.31). The combined use of isometric training of abdominal muscles, breathing exercises and abdominal massage increased defaecation frequency after 6 weeks but faecal incontinence remained unchanged. Physiotherapy may be a useful treatment for constipation. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.
Volpe, M; Scaldaferri, F; Ojetti, V; Poscia, A
2013-01-01
The high demand of Breath Tests (BT) in many gastroenterological conditions in time of limited resources for health care systems, generates increased interest in cost analysis from the point of view of the delivery of services to better understand how use the money to generate value. This study aims to measure the cost of C13 Urea and other most utilized breath tests in order to describe key aspects of costs and reimbursements looking at the economic sustainability for the hospital. A hospital based cost-analysis of the main breath tests commonly delivery in an ambulatory setting is performed. Mean salary for professional nurses and gastroenterologists, drugs/preparation used and disposable materials, purchase and depreciation of the instrument and the testing time was used to estimate the cost, while reimbursements are based on the 2013 Italian National Health System ambulatory pricelist. Variables that could influence the model are considered in the sensitivity analyses. The mean cost for C13--Urea, Lactulose and Lactose BT are, respectively, Euros 30,59; 45,20 and 30,29. National reimbursement often doesn't cover the cost of the analysis, especially considering the scenario with lower number of exam. On the contrary, in high performance scenario all the reimbursement could cover the cost, except for the C13 Urea BT that is high influenced by the drugs cost. However, consideration about the difference between Italian Regional Health System ambulatory pricelist are done. Our analysis shows that while national reimbursement rates cover the costs of H2 breath testing, they do not cover sufficiently C13 BT, particularly urea breath test. The real economic strength of these non invasive tests should be considered in the overall organization of inpatient and outpatient clinic, accounting for complete diagnostic pathway for each gastrointestinal disease.
Dinesen, L; Caspary, W F; Chapman, R W; Dietrich, C F; Sarrazin, C; Braden, B
2008-09-01
The (13)C-methacetin-breath test and also several noninvasive blood tests comprising routine laboratory parameters have been proposed to predict fibrosis and cirrhosis in chronic hepatitis C. The aim of the study was to compare the diagnostic accuracy between these tests referring to hepatic histology as gold standard. 96 patients with chronic hepatitis C virus infection underwent percutaneous liver biopsy and the (13)C-methacetin-breath test. The Fibroindex, the aspartate aminotransferase to platelet ratio index , and the aspartate aminotransferase to alanine aminotransferase ratio were used as parameters for the staging of fibrosis. The main endpoint was the area under the characteristic curves for the diagnosis of advanced fibrosis (F3-F4) and cirrhosis (F4) according to the Batts Ludwig criteria. ROC analysis revealed a cut-off <14.6 per thousand best with 92.6% sensitivity and 84.1% specificity for the (13)C-methacetin-breath test, for the Fibroindex >1.82 70.4% sensitivity and 91.3% specificity, for the aspartate aminotransferase to platelet ratio >1.0 a 66.7% sensitivity and 75.4% specificity, and for the aspartate aminotransferase to alanine aminotransferase ratio >1.0 63.0% sensitivity and 59.4% specificity in predicting liver cirrhosis. The areas under the curve for the breath test, the Fibroindex, aspartate aminotransferase to platelet ratio and the aspartate aminotransferase to alanine aminotransferase ratio were 0.958, 0.845, 0.799, and 0.688, respectively, when predicting cirrhosis. For identifying patients with advanced fibrosis, the areas under the curve were 0.827, 0.804, 0.779, and 0.561, respectively. Discordances between Fibroindex (21%), aspartate aminotransferase to platelet ratio (29%) or aspartate aminotransferase to alanine aminotransferase ratio (37.6%) and liver biopsy were significantly more frequent than between (13)C-breath test (11.6%) and liver biopsy (P<0.05). The (13)C-methacetin-breath test is more reliable in predicting advanced fibrosis and cirrhosis than simple biochemical parameters (aspartate aminotransferase to platelet ratio; aspartate aminotransferase to alanine aminotransferase ratio).
Nardi, Antonio E; Valença, Alexandre M; Mezzasalma, Marco A; Levy, Sandra P; Lopes, Fabiana L; Nascimento, Isabella; Freire, Rafael C; Veras, Andre B; Zin, Walter A
2006-06-15
Our aim was to compare the demographic and psychopathological features of panic disorder (PD) patients who underwent hyperventilation and breath-holding challenge tests, and to describe the features of patients who had a panic attack after both tests versus those patients who did not experience panic after either test. Eighty-five PD patients were induced to hyperventilate (30 breaths/min) for 4 min, and a week later to hold their breath for as long as possible four times with a 2-min interval in between. Anxiety scales were applied before and after the tests. Patients who responded with a panic attack to both tests (BPA, n = 25) were compared with patients who experienced spontaneous panic attacks but did not panic in response to the two tests (NPA, n = 16). The BPA group had a significantly higher presence of respiratory symptoms during a panic attack. The criteria for the respiratory PD subtype were fulfilled in 18 (72.0%) BPA patients and in 6 (37.5%) NPA patients. The BPA patients had a later onset of panic disorder and a higher familial prevalence of PD. Our data suggest that there is a distinction between PD patients who were sensitive to both hyperventilation and breath-holding tests and PD patients who were not affected by the challenge tests. The panic attack may be a final common pathway for different types of stimuli, and respiratory tests may characterize different PD subgroups.
Coelho, Luiz Gonzaga; Sant'Ana, Carlos Roberto; Oliveira, Ricardo Brandt de; Cezar, Raíra César E; Araujo, Aline Cordeiro Campos de; Silva, Raisa Cristina Teodoro da; Trindade, Osmar Reni; Coelho, Maria Clara; Ferrioli, Eduardo; Bendassolli, José Albertino
2018-06-07
The 13C-urea breath test is the main non-invasive test for the diagnosis of Helicobacter pylori infection. The availability of this test throughout the country is limited, mainly due to the difficulty in obtaining the labeled isotope from abroad. Recently, researchers from the Nuclear Energy Center in Agriculture at the University of São Paulo (CENA/USP) succeeded in synthesizing 13C-enriched urea for Helicobacter pylori diagnosis. The aim of the study was to compare the performance of the 13C-urea breath test using 13C-urea acquired abroad with that of a test using 13C-urea synthesized in Brazil. Sixty-four dyspeptic patients participated in the study (24 men and 40 women). Initially, the patients performed the 13C-urea breath test using the imported substrate (Euriso-Top, France). Seven to fourteen days later, all the patients repeated the test using the Brazilian substrate. The samples from both examinations were processed in an infrared isotope analyzer (IRIS, Wagner Analisen Technik, Germany), and all delta over baseline (DOB) [%] values above four were considered positive results. Twenty-seven patients (42%) exhibited negative results for Helicobacter pylori infection, and thirty-seven patients (58%) exhibited positive results when tested using the foreign substrate (gold standard). There was a 100% concordance regarding the presence or absence of infection when the gold standard results were compared with those obtained using the Brazilian substrate. Similar performance in the diagnosis of Helicobacter pylori infection was demonstrated when using the 13C-urea breath test with the Brazilian 13C-urea substrate and the test with the substrate produced abroad. This validation represents an important step toward increasing the availability of the 13C-urea breath test throughout the country, which will have a positive influence on the management of Helicobacter pylori infection.
The Effect of Alcohol-Based Hand Sanitizer Vapors on Evidential Breath Alcohol Test Results.
Strawsine, Ellen; Lutmer, Brian
2017-11-16
This study was undertaken to determine if the application of alcohol-based hand sanitizers (ABHSs) to the hands of a breath test operator will affect the results obtained on evidential breath alcohol instruments (EBTs). This study obtained breath samples on three different EBTs immediately after application of either gel or foam ABHS to the operator's hands. A small, but significant, number of initial analyses (13 of 130, 10%) resulted in positive breath alcohol concentrations, while 41 samples (31.5%) resulted in a status code. These status codes were caused by ethanol vapors either in the room air or their inhalation by the subject, thereby causing a mouth alcohol effect. Replicate subject samples did not yield any consecutive positive numeric results. As ABHS application can cause a transitory mouth alcohol effect via inhalation of ABHS vapors, EBT operators should forego the use of ABHS in the 15 min preceding subject testing. © 2017 American Academy of Forensic Sciences.
Synthesis of ¹³C-lidocaine as a probe of breath test for the evaluation of cytochrome P450 activity.
Mitome, Hidemichi; Sugiyama, Erika; Sato, Hitoshi; Akira, Kazuki
2014-01-01
(13)C-Labeled lidocaine, 2-di[1-(13)C]ethylamino-N-(2,6-dimethylphenyl)acetamide (1), was synthesized from [1-(13)C]acetic acid in six steps, as a probe for a breath test to evaluate in vivo cytochrome P450 activity. The measurement of (13)CO2 in breath was successfully performed following oral administration of (13)C-lidocaine 1 to mice.
Westerdahl, Elisabeth; Lindmark, Birgitta; Eriksson, Tomas; Friberg, Orjan; Hedenstierna, Göran; Tenling, Arne
2005-11-01
To investigate the effects of deep-breathing exercises on pulmonary function, atelectasis, and arterial blood gas levels after coronary artery bypass graft (CABG) surgery. In a prospective, randomized trial, patients performing deep-breathing exercises (n = 48) were compared to a control group (n = 42) who performed no breathing exercises postoperatively. Patient management was similar in the groups in terms of assessment, positioning, and mobility. The patients in the deep-breathing group were instructed to perform breathing exercises hourly during daytime for the first 4 postoperative days. The exercises consisted of 30 slow, deep breaths performed with a positive expiratory pressure blow-bottle device (+ 10 cm H(2)O). Spirometric measurements, spiral CT (three transverse levels), arterial blood gas analysis, and scoring of subjective experience of the breathing exercises were performed on the fourth postoperative day. Atelectasis was only half the size in the deep-breathing group compared to the control group, amounting to 2.6 +/- 2.2% vs 4.7 +/- 5.7% (p = 0.045) at the basal level and 0.1 +/- 0.2% vs 0.3 +/- 0.5% (mean +/- SD) [p = 0.01] at the apical level. Compared to the control subjects, the patients in the deep-breathing group had a significantly smaller reduction in FVC (to 71 +/- 12%, vs 64 +/- 13% of the preoperative values; p = 0.01) and FEV(1) (to 71 +/- 11%, vs 65 +/- 13% of the preoperative values; p = 0.01). Arterial oxygen tension, carbon dioxide tension, fever, or length of ICU or hospital stay did not differ between the groups. In the deep-breathing group, 72% of the patients experienced a subjective benefit from the exercises. Patients performing deep-breathing exercises after CABG surgery had significantly smaller atelectatic areas and better pulmonary function on the fourth postoperative day compared to a control group performing no exercises.
Emerson, Beth L; Whitfill, Travis; Baum, Carl R; Garlin-Kane, Katherine; Santucci, Karen
2016-12-01
This study aimed to investigate the effects of alcohol-based hand hygiene solution (ABHS) use by care providers on point-of-care alcohol breath analyzer interpretation under different clinically relevant conditions. Among each test condition (foam vehicle with immediate testing, gel vehicle with immediate testing, allowing hands to dry after the use of ABHS, and donning gloves after the use of ABHS), alcohol was detected in breath at 1 minute after use of ABHS. Because the use of ABHS by individuals administering breath alcohol detection may result in false-positive detection of alcohol, staff using these devices should consider traditional hand hygiene with soap and water. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Sullivan, J. L.
1975-01-01
The commercial availability of lightweight high pressure compressed air vessels has resulted in a lightweight firefighter's breathing apparatus. The improved apparatus, and details of its design and development are described. The apparatus includes a compact harness assembly, a backplate mounted pressure reducer assembly, a lightweight bubble-type facemask with a mask mounted demand breathing regulator. Incorporated in the breathing regulator is exhalation valve, a purge valve and a whistle-type low pressure warning that sounds only during inhalation. The pressure reducer assembly includes two pressure reducers, an automatic transfer valve and a signaling device for the low pressure warning. Twenty systems were fabricated, tested, refined through an alternating development and test sequence, and extensively examined in a field evaluation program. Photographs of the apparatus are included.
NASA firefighters breathing system program report
NASA Technical Reports Server (NTRS)
Wood, W. B.
1977-01-01
Because of the rising incidence of respiratory injury to firefighters, local governments expressed the need for improved breathing apparatus. A review of the NASA firefighters breathing system program, including concept definition, design, development, regulatory agency approval, in-house testing, and program conclusion is presented.
Potter, Pamela; Eisenberg, Seth; Cain, Kevin C; Berry, Donna L
2011-01-01
For over 2 decades, oncology nurses at a regional comprehensive cancer center offered sliced oranges to patients during the reinfusion of autologous hematopoietic progenitor cells (HPCs) to relieve symptoms associated with the preservative dimethyl sulfoxide (DMSO). This randomized pilot study examined feasibility and efficacy of sliced orange intervention (OI), orange aromatherapy intervention (OAI), or deep breathing (control) to address unpleasant adverse effects during HPC infusion. Orange intervention sniffed or tasted a quartered orange, OAI sniffed orange aromatherapy, and control took deep breaths. Perceived "symptom intensity" for tickle/cough urge, nausea, retching, and perceived "relief" were measured on 0- to 10-point numerical scales. Sixty of 72 eligible patients consented to participate and were randomized to OI (n = 19), OAI (n = 23), or control (n = 18). Study personnel successfully administered study procedures. Over the course of 2 bags of cells infused, the OI group reported significantly greater relief with the intervention (P = .032). Among participants less than 90 kg, OI group reported significantly lower symptom intensity (P = .012). Results suggest a feasible protocol and potential efficacy of sliced oranges for treating symptoms associated with DMSO-preserved stem cells. Study procedures provide a tested protocol for future studies. Follow-up study is warranted to confirm these findings and evaluate other treatment options. Oranges offer a simple, noninvasive intervention for relieving symptoms associated with DMSO preservative during autologous HPC infusion.
21 CFR 862.3080 - Breath nitric oxide test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...
21 CFR 862.3050 - Breath-alcohol test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...
21 CFR 862.3050 - Breath-alcohol test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...
21 CFR 862.3050 - Breath-alcohol test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...
21 CFR 862.3080 - Breath nitric oxide test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...
21 CFR 862.3080 - Breath nitric oxide test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...
21 CFR 862.3080 - Breath nitric oxide test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...
Coates, Allan L; Wanger, Jack; Cockcroft, Donald W; Culver, Bruce H; Diamant, Zuzana; Gauvreau, Gail; Hall, Graham L; Hallstrand, Teal S; Horvath, Ildiko; de Jongh, Frans H C; Joos, Guy; Kaminsky, David A; Laube, Beth L; Leuppi, Joerg D; Sterk, Peter J
2017-05-01
This international task force report updates general considerations for bronchial challenge testing and the performance of the methacholine challenge test. There are notable changes from prior recommendations in order to accommodate newer delivery devices. Rather than basing the test result upon a methacholine concentration (provocative concentration (PC 20 ) causing a 20% fall in forced expiratory volume in 1 s (FEV 1 )), the new recommendations base the result upon the delivered dose of methacholine causing a 20% fall in FEV 1 (provocative dose (PD 20 )). This end-point allows comparable results from different devices or protocols, thus any suitable nebuliser or dosimeter may be used, so long as the delivery characteristics are known. Inhalation may be by tidal breathing using a breath-actuated or continuous nebuliser for 1 min (or more), or by a dosimeter with a suitable breath count. Tests requiring maximal inhalations to total lung capacity are not recommended because the bronchoprotective effect of a deep breath reduces the sensitivity of the test. Copyright ©ERS 2017.
Nine months in space: effects on human autonomic cardiovascular regulation.
Cooke, W H; Ames JE, I V; Crossman, A A; Cox, J F; Kuusela, T A; Tahvanainen, K U; Moon, L B; Drescher, J; Baisch, F J; Mano, T; Levine, B D; Blomqvist, C G; Eckberg, D L
2000-09-01
We studied three Russian cosmonauts to better understand how long-term exposure to microgravity affects autonomic cardiovascular control. We recorded the electrocardiogram, finger photoplethysmographic pressure, and respiratory flow before, during, and after two 9-mo missions to the Russian space station Mir. Measurements were made during four modes of breathing: 1) uncontrolled spontaneous breathing; 2) stepwise breathing at six different frequencies; 3) fixed-frequency breathing; and 4) random-frequency breathing. R wave-to-R wave (R-R) interval standard deviations decreased in all and respiratory frequency R-R interval spectral power decreased in two cosmonauts in space. Two weeks after the cosmonauts returned to Earth, R-R interval spectral power was decreased, and systolic pressure spectral power was increased in all. The transfer function between systolic pressures and R-R intervals was reduced in-flight, was reduced further the day after landing, and had not returned to preflight levels by 14 days after landing. Our results suggest that long-duration spaceflight reduces vagal-cardiac nerve traffic and decreases vagal baroreflex gain and that these changes may persist as long as 2 wk after return to Earth.
Sleep-Disordered Breathing in Heart Failure - A Therapeutic Dilemma.
Haruki, Nobuhiko; Floras, John S
2017-06-23
Sleep-disordered breathing (SDB) occurs in approximately 50% of patients with reduced left ventricular ejection fraction receiving contemporary heart failure (HF) therapies. Obstructive (OSA) and central sleep apneas (CSA) interrupt breathing by different mechanisms but impose qualitatively similar autonomic, chemical, mechanical, and inflammatory burdens on the heart and circulation. Because contemporary evidence-based drug and device HF therapies have little or no mitigating effect on the acute or long-term consequences of such stimuli, there is a sound mechanistic rationale for targeting SDB to reduce cardiovascular event rates and prolong life. However, the promise of observational studies and randomized trials of small size and duration describing a beneficial effect of treating SDB in HF via positive airway pressure was not realized in 2 recent randomized outcome-driven trials: SAVE, which evaluated the cardiovascular effect of treating OSA in a cohort without HF, and SERVE-HF, which reported the results of a strategy of random allocation of minute-ventilation-triggered adaptive servo-ventilation (ASV) for HF patients with CSA. Whether effective treatment of either OSA or CSA improves the HF trajectory by reducing cardiovascular morbidity or mortality has yet to be definitively established. ADVENT-HF, designed to determine the effect of treating both CSA and non-sleepy OSA HF patients with a peak-airflow triggered ASV algorithm, could resolve this present clinical equipoise concerning the treatment of SDB.
Lactose (mal)digestion evaluated by the 13C-lactose digestion test.
Vonk, R J; Lin, Y; Koetse, H A; Huang, C; Zeng, G; Elzinga, H; Antoine, J; Stellaard, F
2000-02-01
The prevalence of genetically determined lactase nonpersistence is based on the results of the lactose H2 breath test. This test, however, is an indirect test, which might lead to misinterpretation. We determined lactase activity in healthy Chinese and Dutch students using a novel 13C-lactose digestion test. The cut-off value of this test was established in a Chinese population with a homogenous genetic background of lactase nonpersistence and was compared with the results obtained in a Caucasian population. Twenty-five grams of a 13C-lactose solution was consumed by 12 known H2-positive and 5 H2-negative Chinese students and 48 Dutch students and, subsequently, 13C-glucose concentration in plasma and H2 excretion in breath were measured. A similar 13C-glucose response curve was found in all Chinese students. The mean response curve in the Dutch students was more pronounced (P < 0.01). The 1 h (peak) plasma 13C-glucose concentration was the best discriminator between lactose digesting and maldigesting subjects. The cut-off level of 2 mmol L-1 13C-glucose in plasma was defined in the H2-positive Chinese students group. Based on the 13C-glucose response the prevalence of lactose maldigestion in the Dutch subjects was 25%; based on the lactose H2 breath test 17%. Using the 13C-lactose digestion test the results demonstrate a higher prevalence of lactose maldigestion in a Caucasian population than indicated by the results of the H2 breath test. A moderate increase in the plasma 13C-glucose concentration after consumption of 13C-lactose in the young adult Chinese subjects indicates a residual lactase activity in that age group, even when a positive H2 breath test result is obtained. These results indicate that the 13C-glucose concentration in plasma more accurately reflects the small intestinal lactose digestion capacity than the lactose H2 breath test.
Allen, Scott G; Brewer, Lara; Gillis, Erik S; Pace, Nathan L; Sakata, Derek J; Orr, Joseph A
2017-09-01
Research has shown that increased breathing frequency during cardiopulmonary resuscitation is inversely correlated with systolic blood pressure. Rescuers often hyperventilate during cardiopulmonary resuscitation (CPR). Current American Heart Association advanced cardiac life support recommends a ventilation rate of 8-10 breaths/min. We hypothesized that a small, turbine-driven ventilator would allow rescuers to adhere more closely to advanced cardiac life support (ACLS) guidelines. Twenty-four ACLS-certified health-care professionals were paired into groups of 2. Each team performed 4 randomized rounds of 2-min cycles of CPR on an intubated mannikin, with individuals altering between compressions and breaths. Two rounds of CPR were performed with a self-inflating bag, and 2 rounds were with the ventilator. The ventilator was set to deliver 8 breaths/min, pressure limit 22 cm H 2 O. Frequency, tidal volume (V T ), peak inspiratory pressure, and compression interruptions (hands-off time) were recorded. Data were analyzed with a linear mixed model and Welch 2-sample t test. The median (interquartile range [IQR]) frequency with the ventilator was 7.98 (7.98-7.99) breaths/min. Median (IQR) frequency with the self-inflating bag was 9.5 (8.2-10.7) breaths/min. Median (IQR) ventilator V T was 0.5 (0.5-0.5) L. Median (IQR) self-inflating bag V T was 0.6 (0.5-0.7) L. Median (IQR) ventilator peak inspiratory pressure was 22 (22-22) cm H 2 O. Median (IQR) self-inflating bag peak inspiratory pressure was 30 (27-35) cm H 2 O. Mean ± SD hands-off times for ventilator and self-inflating bag were 5.25 ± 2.11 and 6.41 ± 1.45 s, respectively. When compared with a ventilator, volunteers ventilated with a self-inflating bag within ACLS guidelines. However, volunteers ventilated with increased variation, at higher V T levels, and at higher peak pressures with the self-inflating bag. Hands-off time was also significantly lower with the ventilator. (ClinicalTrials.gov registration NCT02743299.). Copyright © 2017 by Daedalus Enterprises.
Yamamoto, Y; Kouda, M; Abe, K; Sakurabayashi, S; Sezai, S; Hirano, M; Oka, H
1995-11-01
Up to now, the diagnosis of H. pylori infection has been made by the breath test using 13C-urea. In this study, 13C-urea breath samples were tested in 34 patients (peptic ulcer scar 17, chronic gastritis 17 cases) with an automated breath 13C analyzer (ABCA. Europa Scientific, Crewe, UK) and compared with the results of endoscopical diagnosis for H. pylori infection. Endoscopic and 13C-urea breath test (13C-UBT) were performed before eradicative medication. We described a modified protocol for the growth grade of H. pylori colonies in microbiology (H. pylori score), and for the delta 13C area under curve (AUC; permil*hr) obtained from each sample of expired breath. There was a significant correlation between delta 13C-AUC and the delta 13C level of each sample, but the correlation coefficient obtained at 10min (R2 = 0.582) was lower than that obtained at the other four time points (20min; 0.891, 30min; 0.949, 40min; 0.946, 50min; 0.946, 60min; 0.820). The delta 13C-AUC well correlated with H. pylori score (p < 0.01), none of 26 H. pylori positive patients detected by culture was 13C-UBT negative (delta 13C-AUC < 8.2 permil*hr in mean + 2SD of H. pylori negative group). In conclusion, 13C-UBT using ABCA has high sensitivity and specificity, and it provides a non-invasive method for the detection of H. pylori urease activity.
Delso, Gaspar; Khalighi, Mohammed; Ter Voert, Edwin; Barbosa, Felipe; Sekine, Tetsuro; Hüllner, Martin; Veit-Haibach, Patrick
2017-01-01
Purpose To evaluate the magnitude and anatomic extent of the artifacts introduced on positron emission tomographic (PET)/magnetic resonance (MR) images by respiratory state mismatch in the attenuation map. Materials and Methods The method was tested on 14 patients referred for an oncologic examination who underwent PET/MR imaging. The acquisition included standard PET and MR series for each patient, and an additional attenuation correction series was acquired by using breath hold. PET data were reconstructed with and without time-of-flight (TOF) information, first by using the standard free-breathing attenuation map and then again by using the additional breath-hold map. Two-tailed paired t testing and linear regression with 0 intercept was performed on TOF versus non-TOF and free-breathing versus breath-hold data for all detected lesions. Results Fluorodeoxyglucose-avid lesions were found in eight of the 14 patients included in the study. The uptake differences (maximum standardized uptake values) between PET reconstructions with free-breathing versus breath-hold attenuation ranged, for non-TOF reconstructions, from -18% to 26%. The corresponding TOF reconstructions yielded differences from -15% to 18%. Conclusion TOF information was shown to reduce the artifacts caused at PET/MR by respiratory mismatch between emission and attenuation data. © RSNA, 2016 Online supplemental material is available for this article.
Poor predictive value of breath hydrogen response for probiotic effects in IBS.
Yao, Chu K; Barrett, Jacqueline S; Philpott, Hamish; Chung, Alvin R T; van Langenberg, Daniel; Garg, Mayur; Gibson, Peter R
2015-12-01
Previous observations suggested that an early rise in breath hydrogen after lactulose (ERBHAL) may identify patients with irritable bowel syndrome (IBS) likely to respond to probiotics. Therefore, we aimed to (i) investigate whether treatment with a probiotic changes breath hydrogen response in patients with ERBHAL and (ii) whether these changes identify patients who may benefit symptomatically from probiotics. In a randomized, double-blind, placebo-controlled trial, patients with IBS (Rome III) were randomized to either 65 mL/day fermented milk product containing probiotic (FMPP) or placebo for 6 weeks, followed by 6 weeks' open-label treatment and 6 weeks' withdrawal. Breath hydrogen responses to lactulose (15 g) and liquid-gastric emptying time were evaluated before and at the end of each treatment period. Symptoms were measured using a 100-mm visual analog scale. Loss of ERBHAL occurred in 36% of 23 patients receiving FMPP and 41% of 22 receiving placebo (P = 1.00). Amongst 40 patients who completed open-label FMPP treatment, ERBHAL was lost in a further 38%, continued in 25%, and regained in 10%. Similar variability occurred in the withdrawal phase. Variability was unrelated to changes in gastric emptying. No differences in symptom response were seen between treatment groups nor in relation to the loss or retention of ERBHAL. Breath hydrogen patterns after lactulose are poorly reproducible. No FMPP-specific effects on fermentation patterns or symptoms were observed. The presence of ERBHAL is not useful to predict symptomatic response to probiotic therapy in patients with IBS. © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
Photoacoustic sensor for VOCs: first step towards a lung cancer breath test
NASA Astrophysics Data System (ADS)
Wolff, Marcus; Groninga, Hinrich G.; Dressler, Matthias; Harde, Hermann
2005-08-01
Development of new optical sensor technologies has a major impact on the progression of diagnostic methods. Specifically, the optical analysis of breath is an extraordinarily promising technique. Spectroscopic sensors for the non-invasive 13C-breath tests (the Urea Breath Test for detection of Helicobacter pylori is most prominent) are meanwhile well established. However, recent research and development go beyond gastroenterological applications. Sensitive and selective detection of certain volatile organic compounds (VOCs) in a patient's breath, could enable the diagnosis of diseases that are very difficult to diagnose with contemporary techniques. For instance, an appropriate VOC biomarker for early-stage bronchial carcinoma (lung cancer) is n-butane (C4H10). We present a new optical detection scheme for VOCs that employs an especially compact and simple set-up based on photoacoustic spectroscopy (PAS). This method makes use of the transformation of absorbed modulated radiation into a sound wave. Employing a wavelength-modulated distributed feedback (DFB) diode laser and taking advantage of acoustical resonances of the sample cell, we performed very sensitive and selective measurements on butane. A detection limit for butane in air in the ppb range was achieved. In subsequent research the sensitivity will be successively improved to match the requirements of the medical application. Upon optimization, our photoacoustic sensor has the potential to enable future breath tests for early-stage lung cancer diagnostics.
Ulyanova, Yevgenia; Babanova, Sofia; Pinchon, Erica; Matanovic, Ivana; Singhal, Sameer; Atanassov, Plamen
2014-07-14
The effect of proper enzyme orientation at the electrode surface was explored for two multi-copper oxygen reducing enzymes: Bilirubin Oxidase (BOx) and Laccase (Lac). Simultaneous utilization of "tethering" agent (1-pyrenebutanoic acid, succinimidyl ester; PBSE), for stable enzyme immobilization, and syringaldazine (Syr), for enzyme orientation, of both Lac and BOx led to a notable enhancement of the electrode performance. For Lac cathodes tested in solution it was established that PBSE-Lac and PBSE-Syr-Lac modified cathodes demonstrated approximately 6 and 9 times increase in current density, respectively, compared to physically adsorbed and randomly oriented Lac cathodes. Further testing in solution utilizing BOx showed an even higher increase in achievable current densities, thus BOx was chosen for additional testing in air-breathing mode. In subsequent air-breathing experiments the incorporation of PBSE and Syr with BOx resulted in current densities of 0.65 ± 0.1 mA cm(-2); 2.5 times higher when compared to an unmodified BOx cathode. A fully tethered/oriented BOx cathode was combined with a NAD-dependent Glucose Dehydrogenase anode for the fabrication of a complete enzymatic membraneless fuel cell. A maximum power of 1.03 ± 0.06 mW cm(-2) was recorded for the complete fuel cell. The observed significant enhancement in the performance of "oriented" cathodes was a result of proper enzyme orientation, leading to facilitated enzyme/electrode interface interactions.
Effect of post-prandial posture on orocecal transit time and digestion of milk lactose in humans.
Hirota, Naoko; Sone, Yoshiaki; Tokura, Hiromi
2004-05-01
We examined the effect of post-prandial body posture on orocecal transit time and absorption of milk lactose using the breath hydrogen test. In this experiment, subjects ingested a cup of commercially available milk to which we had added a small amount of lactosucrose (an indigestible trisaccharide), and then they lay on their backs or sat on a chair for the first 4 hr (from 08:00 to 12:00). After four hours lying or sitting, they remained sedentary on a sofa for the second six hr (from 12:00 to 18:00). Participants' end alveolar breath samples were collected every 15 min from 08:00 to 12:30, then every 30 min from 13:00 to 18:00. The experiment was conducted on two consecutive days using a randomized, crossover study design. Examination showed that the orocecal transit time of the oligosaccharides (lactosucrose and milk lactose) under the post-prandial supine condition was significantly longer than that under the sitting condition. In addition, the amount of breath hydrogen excretion under the supine condition was significantly lower than under the sitting condition, indicating that the unabsorbed milk lactose moved into cecum under the supine condition is smaller than that under the sitting condition. These findings provide evidence that postprandial supine posture works more beneficially to digest and absorb milk lactose when compared to the sitting posture.
Tenth anniversary special issue of the Journal of Breath Research: looking forward
The Journal of Breath Research has now reached its 10th anniversary of publication. From the general public’s perspective, breath analysis had always revolved around drinking and driving, and to some lesser extent pulmonary function testing of athletes. However, at the ince...
46 CFR 197.450 - Breathing gas tests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... taken at the connection point to the distribution system— (1) Every 6 months; and (2) After every repair or modification. (b) Purchased supplies of breathing mixtures supplied to a diver are checked before... commencement of diving operations, at the umbilical or underwater breathing apparatus connection point for the...
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, Célia; Turner, Claire
2014-01-01
Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. “Breath fingerprinting”, indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles. PMID:24957037
Breath analysis in disease diagnosis: methodological considerations and applications.
Lourenço, Célia; Turner, Claire
2014-06-20
Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. "Breath fingerprinting", indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles.
42 CFR 84.96 - Service time test; closed-circuit apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Service time test; closed-circuit apparatus. 84.96...-Contained Breathing Apparatus § 84.96 Service time test; closed-circuit apparatus. (a) The closed-circuit apparatus will be classified according to the length of time it supplies adequate breathing gas to the...
42 CFR 84.96 - Service time test; closed-circuit apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Service time test; closed-circuit apparatus. 84.96...-Contained Breathing Apparatus § 84.96 Service time test; closed-circuit apparatus. (a) The closed-circuit apparatus will be classified according to the length of time it supplies adequate breathing gas to the...
Duiverman, Marieke L; Huberts, Anouk S; van Eykern, Leo A; Bladder, Gerrie; Wijkstra, Peter J
2017-01-01
Introduction High-intensity noninvasive ventilation (NIV) has been shown to improve outcomes in stable chronic obstructive pulmonary disease patients. However, there is insufficient knowledge about whether with this more controlled ventilatory mode optimal respiratory muscle unloading is provided without an increase in patient–ventilator asynchrony (PVA). Patients and methods Ten chronic obstructive pulmonary disease patients on home mechanical ventilation were included. Four different ventilatory settings were investigated in each patient in random order, each for 15 min, varying the inspiratory positive airway pressure and backup breathing frequency. With surface electromyography (EMG), activities of the intercostal muscles, diaphragm, and scalene muscles were determined. Furthermore, pressure tracings were derived simultaneously in order to assess PVA. Results Compared to spontaneous breathing, the most pronounced decrease in EMG activity was achieved with the high-pressure settings. Adding a high breathing frequency did reduce EMG activity per breath, while the decrease in EMG activity over 1 min was comparable with the high-pressure, low-frequency setting. With high backup breathing frequencies less breaths were pressure supported (25% vs 97%). PVAs occurred more frequently with the low-frequency settings (P=0.017). Conclusion High-intensity NIV might provide optimal unloading of respiratory muscles, without undue increases in PVA. PMID:28138234
Duiverman, Marieke L; Huberts, Anouk S; van Eykern, Leo A; Bladder, Gerrie; Wijkstra, Peter J
2017-01-01
High-intensity noninvasive ventilation (NIV) has been shown to improve outcomes in stable chronic obstructive pulmonary disease patients. However, there is insufficient knowledge about whether with this more controlled ventilatory mode optimal respiratory muscle unloading is provided without an increase in patient-ventilator asynchrony (PVA). Ten chronic obstructive pulmonary disease patients on home mechanical ventilation were included. Four different ventilatory settings were investigated in each patient in random order, each for 15 min, varying the inspiratory positive airway pressure and backup breathing frequency. With surface electromyography (EMG), activities of the intercostal muscles, diaphragm, and scalene muscles were determined. Furthermore, pressure tracings were derived simultaneously in order to assess PVA. Compared to spontaneous breathing, the most pronounced decrease in EMG activity was achieved with the high-pressure settings. Adding a high breathing frequency did reduce EMG activity per breath, while the decrease in EMG activity over 1 min was comparable with the high-pressure, low-frequency setting. With high backup breathing frequencies less breaths were pressure supported (25% vs 97%). PVAs occurred more frequently with the low-frequency settings ( P =0.017). High-intensity NIV might provide optimal unloading of respiratory muscles, without undue increases in PVA.
Jiang, Chenyu; Sun, Meixiu; Wang, Zhennan; Chen, Zhuying; Zhao, Xiaomeng; Yuan, Yuan; Li, Yingxin; Wang, Chuji
2016-01-01
Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist among the results of different studies because there has been no “best-practice method” for breath-acetone measurements as a result of technical problems of sampling and analysis. In this mini-review, we update the current status of our development of a laser-based breath acetone analyzer toward real-time, one-line diabetic screening and a point-of-care instrument for diabetic management. An integrated standalone breath acetone analyzer based on the cavity ringdown spectroscopy technique has been developed. The instrument was validated by using the certificated gas chromatography-mass spectrometry. The linear fittings suggest that the obtained acetone concentrations via both methods are consistent. Breath samples from each individual subject under various conditions in total, 1257 breath samples were taken from 22 Type 1 diabetic (T1D) patients, 312 Type 2 diabetic (T2D) patients, which is one of the largest numbers of T2D subjects ever used in a single study, and 52 non-diabetic healthy subjects. Simultaneous blood glucose (BG) levels were also tested using a standard diabetic management BG meter. The mean breath acetone concentrations were determined to be 4.9 ± 16 ppm (22 T1D), and 1.5 ± 1.3 ppm (312 T2D), which are about 4.5 and 1.4 times of the one in the 42 non-diabetic healthy subjects, 1.1 ± 0.5 ppm, respectively. A preliminary quantitative correlation (R = 0.56, p < 0.05) between the mean individual breath acetone concentration and the mean individual BG levels does exist in 20 T1D subjects with no ketoacidosis. No direct correlation is observed in T1D subjects, T2D subjects, and healthy subjects. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone, under a specifically controlled condition fast (<1 min) and portable breath acetone measurement can be used for screening abnormal metabolic status including diabetes, for point-of-care monitoring status of ketone bodies which have the signature smell of breath acetone, and for breath acetone related clinical studies requiring a large number of tests. PMID:27483281
Jiang, Chenyu; Sun, Meixiu; Wang, Zhennan; Chen, Zhuying; Zhao, Xiaomeng; Yuan, Yuan; Li, Yingxin; Wang, Chuji
2016-07-30
Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist among the results of different studies because there has been no "best-practice method" for breath-acetone measurements as a result of technical problems of sampling and analysis. In this mini-review, we update the current status of our development of a laser-based breath acetone analyzer toward real-time, one-line diabetic screening and a point-of-care instrument for diabetic management. An integrated standalone breath acetone analyzer based on the cavity ringdown spectroscopy technique has been developed. The instrument was validated by using the certificated gas chromatography-mass spectrometry. The linear fittings suggest that the obtained acetone concentrations via both methods are consistent. Breath samples from each individual subject under various conditions in total, 1257 breath samples were taken from 22 Type 1 diabetic (T1D) patients, 312 Type 2 diabetic (T2D) patients, which is one of the largest numbers of T2D subjects ever used in a single study, and 52 non-diabetic healthy subjects. Simultaneous blood glucose (BG) levels were also tested using a standard diabetic management BG meter. The mean breath acetone concentrations were determined to be 4.9 ± 16 ppm (22 T1D), and 1.5 ± 1.3 ppm (312 T2D), which are about 4.5 and 1.4 times of the one in the 42 non-diabetic healthy subjects, 1.1 ± 0.5 ppm, respectively. A preliminary quantitative correlation (R = 0.56, p < 0.05) between the mean individual breath acetone concentration and the mean individual BG levels does exist in 20 T1D subjects with no ketoacidosis. No direct correlation is observed in T1D subjects, T2D subjects, and healthy subjects. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone, under a specifically controlled condition fast (<1 min) and portable breath acetone measurement can be used for screening abnormal metabolic status including diabetes, for point-of-care monitoring status of ketone bodies which have the signature smell of breath acetone, and for breath acetone related clinical studies requiring a large number of tests.
Mathematical and statistical approaches for interpreting biomarker compounds in exhaled human breath
The various instrumental techniques, human studies, and diagnostic tests that produce data from samples of exhaled breath have one thing in common: they all need to be put into a context wherein a posed question can actually be answered. Exhaled breath contains numerous compoun...
Xu, Jian; Mcgorty, Kelly Anne; Lim, Ruth. P.; Bruno, Mary; Babb, James S.; Srichai, Monvadi B.; Kim, Daniel; Sodickson, Daniel K.
2011-01-01
OBJECTIVE To evaluate the feasibility of performing single breath-hold 3D thoracic non-contrast magnetic resonance angiography (NC-MRA) using highly-accelerated parallel imaging. MATERIALS AND METHODS We developed a single breath-hold NC MRA pulse sequence using balanced steady state free precession (SSFP) readout and highly-accelerated parallel imaging. In 17 subjects, highly-accelerated non-contrast MRA was compared against electrocardiogram (ECG)-triggered contrast-enhanced MRA. Anonymized images were randomized for blinded review by two independent readers for image quality, artifact severity in 8 defined vessel segments and aortic dimensions in 6 standard sites. NC-MRA and CE-MRA were compared in terms of these measures using paired sample t and Wilcoxon tests. RESULTS The overall image quality (3.21±0.68 for NC-MRA vs. 3.12±0.71 for CE-MRA) and artifact (2.87±1.01 for NC-MRA vs. 2.92±0.87 for CE-MRA) scores were not significantly different, but there were significant differences for the great vessel and coronary artery origins. NC-MRA demonstrated significantly lower aortic diameter measurements compared to CE-MRA; however, this difference was not considered clinically relevant (>3 mm difference) for less than 12% of segments, most commonly at the sinotubular junction. Mean total scan time was significantly lower for NC-MRA compared to CE-MRA (18.2 ± 6.0s vs. 28.1 ± 5.4s, respectively; p < 0.05). CONCLUSION Single breath-hold NC-MRA is feasible and can be a useful alternative for evaluation and follow-up of thoracic aortic diseases. PMID:22147589
Kallet, Richard H; Campbell, Andre R; Dicker, Rochelle A; Katz, Jeffrey A; Mackersie, Robert C
2005-12-01
Pressure-control ventilation (PCV) and pressure-regulated volume-control (PRVC) ventilation are used during lung-protective ventilation because the high, variable, peak inspiratory flow rate (V (I)) may reduce patient work of breathing (WOB) more than the fixed V (I) of volume-control ventilation (VCV). Patient-triggered breaths during PCV and PRVC may result in excessive tidal volume (V(T)) delivery unless the inspiratory pressure is reduced, which in turn may decrease the peak V (I). We tested whether PCV and PRVC reduce WOB better than VCV with a high, fixed peak V (I) (75 L/min) while also maintaining a low V(T) target. Fourteen nonconsecutive patients with acute lung injury or acute respiratory distress syndrome were studied prospectively, using a random presentation of ventilator modes in a crossover, repeated-measures design. A target V(T) of 6.4 + 0.5 mL/kg was set during VCV and PRVC. During PCV the inspiratory pressure was set to achieve the same V(T). WOB and other variables were measured with a pulmonary mechanics monitor (Bicore CP-100). There was a nonsignificant trend toward higher WOB (in J/L) during PCV (1.27 + 0.58 J/L) and PRVC (1.35 + 0.60 J/L), compared to VCV (1.09 + 0.59 J/L). While mean V(T) was not statistically different between modes, in 40% of patients, V(T) markedly exceeded the lung-protective ventilation target during PRVC and PCV. During lung-protective ventilation, PCV and PRVC offer no advantage in reducing WOB, compared to VCV with a high flow rate, and in some patients did not allow control of V(T) to be as precise.
Ryerson, Christopher J; Camp, Pat G; Eves, Neil D; Schaeffer, Michele; Syed, Nafeez; Dhillon, Satvir; Jensen, Dennis; Maltais, Francois; O'Donnell, Denis E; Raghavan, Natya; Roman, Michael; Stickland, Michael K; Assayag, Deborah; Bourbeau, Jean; Dion, Genevieve; Fell, Charlene D; Hambly, Nathan; Johannson, Kerri A; Kalluri, Meena; Khalil, Nasreen; Kolb, Martin; Manganas, Helene; Morán-Mendoza, Onofre; Provencher, Steve; Ramesh, Warren; Rolf, J Douglass; Wilcox, Pearce G; Guenette, Jordan A
2016-09-01
Pulmonary rehabilitation improves dyspnea and exercise capacity in idiopathic pulmonary fibrosis (IPF); however, it is unknown whether breathing high amounts of oxygen during exercise training leads to further benefits. Herein, we describe the design of the High Oxygen Delivery to Preserve Exercise Capacity in IPF Patients Treated with Nintedanib study (the HOPE-IPF study). The primary objective of this study is to determine the physiological and perceptual impact of breathing high levels of oxygen during exercise training in patients with IPF who are receiving antifibrotic therapy. HOPE-IPF is a two-arm double-blind multicenter randomized placebo-controlled trial of 88 patients with IPF treated with nintedanib. Patients will undergo 8 weeks of three times weekly aerobic cycle exercise training, breathing a hyperoxic gas mixture with a constant fraction of 60% inhaled oxygen, or breathing up to 40% oxygen as required to maintain an oxygen saturation level of at least 88%. End points will be assessed at baseline, postintervention (Week 8), and follow-up (Week 26). The primary analysis will compare the between-group baseline with post-training change in endurance time during constant work rate cycle exercise tests. Additional analyses will evaluate the impact of training with high oxygen delivery on 6-minute walk distance, dyspnea, physical activity, and quality of life. The HOPE-IPF study will lead to a comprehensive understanding of IPF exercise physiology, with the potential to change clinical practice by indicating the need for increased delivery of supplemental oxygen during pulmonary rehabilitation in patients with IPF. Clinical trial registered with www.clinicaltrials.gov (NCT02551068).
DNA damage may drive nucleosomal reorganization to facilitate damage detection
NASA Astrophysics Data System (ADS)
LeGresley, Sarah E.; Wilt, Jamie; Antonik, Matthew
2014-03-01
One issue in genome maintenance is how DNA repair proteins find lesions at rates that seem to exceed diffusion-limited search rates. We propose a phenomenon where DNA damage induces nucleosomal rearrangements which move lesions to potential rendezvous points in the chromatin structure. These rendezvous points are the dyad and the linker DNA between histones, positions in the chromatin which are more likely to be accessible by repair proteins engaged in a random search. The feasibility of this mechanism is tested by considering the statistical mechanics of DNA containing a single lesion wrapped onto the nucleosome. We consider lesions which make the DNA either more flexible or more rigid by modeling the lesion as either a decrease or an increase in the bending energy. We include this energy in a partition function model of nucleosome breathing. Our results indicate that the steady state for a breathing nucleosome will most likely position the lesion at the dyad or in the linker, depending on the energy of the lesion. A role for DNA binding proteins and chromatin remodelers is suggested based on their ability to alter the mechanical properties of the DNA and DNA-histone binding, respectively. We speculate that these positions around the nucleosome potentially serve as rendezvous points where DNA lesions may be encountered by repair proteins which may be sterically hindered from searching the rest of the nucleosomal DNA. The strength of the repositioning is strongly dependent on the structural details of the DNA lesion and the wrapping and breathing of the nucleosome. A more sophisticated evaluation of this proposed mechanism will require detailed information about breathing dynamics, the structure of partially wrapped nucleosomes, and the structural properties of damaged DNA.
Breath Test Refusals and Their Effect on DWI Prosecution
DOT National Transportation Integrated Search
2012-07-01
This report describes the design and results of a project aimed at estimating the rate that drivers : refuse to submit to a legally-requested breath alcohol concentration test, and the effect of such : refusals on the prosecution of DWI cases. The st...
Performance evaluation : balloon-type breath alcohol self tester for personal use
DOT National Transportation Integrated Search
1984-01-01
The accuracy of the only breath alcohol balloon-type self test device being marketed for personal use (Luckey Laboratories DM-2) was assessed in the laboratory. Data regarding this self-test device's ability to accurately classify an individual as ha...
Inward contaminant leakage tests of the S-Tron Corporation emergency escape breathing device.
DOT National Transportation Integrated Search
1992-04-01
At the request of S-Tron Corporation, to support their contract with the U.S. Navy, performance tests of the Emergency Escape Breathing Device (EEBD) were conducted in the Environmental Physiology Research Section contaminant leakage chamber. Sulfur ...
A study of characteristics of a reliable and practical breath alcohol screening test. Part A
DOT National Transportation Integrated Search
1975-08-01
The objectives of this study were (1) to investigate several commercially available breath-alcohol screening test devices of the length-of-stain type, under standardized laboratory conditions, with respect to their ability satisfactorily to detect an...
Tveito, Kari; Hetta, Anne Kristine; Askedal, Mia; Brunborg, Cathrine; Sandvik, Leiv; Løberg, Else Marit; Skar, Viggo
2011-07-01
We recently developed a (13)C-sorbitol breath test ((13)C-SBT) as an alternative to the H(2)-sorbitol breath test (H(2)-SBT) for coeliac disease. In this study we compared the diagnostic properties of the H(2)-SBT and the (13)C-SBT in follow-up of coeliac disease. Twenty-seven coeliac patients on a gluten-free diet (GFD) performed the breath tests. All had been tested before treatment in the initial study of the (13)C-SBT, in which 39 untreated coeliac patients, 40 patient controls, and 26 healthy volunteers participated. Five gram sorbitol and 100 mg (13)C-sorbitol were dissolved in 250 ml tap water and given orally. H(2), CH(4) and (13)CO(2) were measured in end-expiratory breath samples every 30 min for 4 h. Increased H(2) concentration ≥20 ppm from basal values was used as cut-off for the H(2)-SBT. Sixty minutes values were used as diagnostic index in the (13)C-SBT. (13)CO(2) levels at 60 min increased in 20/26 treated coeliac patients (77%) after GFD, but were significantly lower than in control groups. Out of 20 patients who had a positive H(2)-SBT before GFD, 12 had a negative H(2)-SBT after GFD. Peak H(2) concentrations were not correlated with (13)C-SBT results. The study confirms the sensitivity of a one-hour (13)C-SBT for small intestinal malabsorption. The (13)C-SBT has superior diagnostic properties compared with the H(2)-SBT in follow-up of coeliac disease.
Code of Federal Regulations, 2010 CFR
2010-10-01
... a breath tube ASD? (a) As the STT or BAT, you must take the following steps when using the saliva... ATF. (b) As the STT or BAT, you must take the following steps when using the breath tube ASD: (1... the manufacturer's directions. (11) You must note the fact that you used a breath tube device in Step...
2010-01-01
Background Anxiety in patients with chronic obstructive pulmonary disease (COPD) is associated with self-reported disability. The purpose of this study is to determine whether there is an association between anxiety and functional measures, quality of life and dyspnea. Methods Data from 1828 patients with moderate to severe emphysema enrolled in the National Emphysema Treatment Trial (NETT), collected prior to rehabilitation and randomization, were used in linear regression models to test the association between anxiety symptoms, measured by the Spielberger State Trait Anxiety Inventory (STAI) and: (a) six-minute walk distance test (6 MWD), (b) cycle ergometry peak workload, (c) St. Georges Respiratory Questionnaire (SRGQ), and (d) UCSD Shortness of Breath Questionnaire (SOBQ), after controlling for potential confounders including age, gender, FEV1 (% predicted), DLCO (% predicted), and the Beck Depression Inventory (BDI). Results Anxiety was significantly associated with worse functional capacity [6 MWD (B = -0.944, p < .001), ergometry peak workload (B = -.087, p = .04)], quality of life (B = .172, p < .001) and shortness of breath (B = .180, p < .001). Regression coefficients show that a 10 point increase in anxiety score is associated with a mean decrease in 6 MWD of 9 meters, a 1 Watt decrease in peak exercise workload, and an increase of almost 2 points on both the SGRQ and SOBQ. Conclusion In clinically stable patients with moderate to severe emphysema, anxiety is associated with worse exercise performance, quality of life and shortness of breath, after accounting for the influence of demographic and physiologic factors known to affect these outcomes. Trail Registration ClinicalTrials.gov NCT00000606 PMID:20214820
Replacement of digestible by resistant starch lowers diet-induced thermogenesis in healthy men.
Heijnen, M L; Deurenberg, P; van Amelsvoort, J M; Beynen, A C
1995-03-01
The present study describes the effect of replacement of digestible starch by resistant starch (RS) on diet-induced thermogenesis (DIT), postprandial glucose and insulin responses, and colonic fermentation. Ten healthy males consumed three test meals, consisting of diluted, artificially-sweetened fruit syrup and either 50 g raw potato starch (550 g RS/kg), or 50 g pregelatinized potato starch (0 g RS/kg) or 30 g pregelatinized potato starch plus 20 g lactulose (670 g indigestible disaccharide/kg). The meals were served in the morning after an overnight fast. Each volunteer consumed each meal twice on six separate days in random order. Metabolic rate was measured by indirect calorimetry in the fasting state for 15 min and postprandially for 5 h. Shortly before and hourly up to 7 h after consumption of the test meal, end-expiratory breath samples were obtained for H2 and CH4 analysis. Shortly before the meal and 30, 60, 180, and 300 min postprandially, blood samples were taken for glucose and insulin analyses. Postprandial increases in glucose and insulin levels were proportional to the amount of digestible carbohydrate in the meal. Breath H2 and CH4 concentrations indicated that the pregelatinized starch was not fermented and that lactulose was fermented rapidly. Fermentation of the raw starch started only 6 to 7 h after consumption, resulting in a rise in breath H2 but not in CH4. The replacement of 27 g digestible starch by RS in a single meal lowered DIT by on average 90 kJ/5 h, as could also be calculated by assuming that RS does not contribute to DIT. The ingestion of lactulose resulted in a substantial rise in DIT which was most probably caused by its fermentation.
Drinking Drivers and Drug Use on Weekend Nights in the United States*
Voas, Robert B.; Lacey, John H.; Jones, Kristina; Scherer, Michael; Compton, Richard
2012-01-01
BACKGROUND Studies of drinking drivers in alcohol-related crashes have shown that high breath-alcohol concentrations (BrACs) are associated with illegal drug use. Until the 2007 National Roadside Survey (NRS), the prevalence of drugs among drinking drivers on U.S. roads was unknown. Using NRS data, we explore how many drivers with positive BrACs may also be using drugs and their significance to current drinking-driving enforcement procedures. METHODS Based on a stratified, random sample covering the 48 U.S. contiguous states, we conducted surveys on weekend nights from July-November 2007. Of the 8,384 eligible motorists contacted, 85.4% provided a breath sample; 70.0%, an oral fluid sample; and 39.1%, a blood sample. We conducted regression analyses on 5,912 participants with a breath test and an oral fluid or blood test. The dependent variables of interest were illegal drugs (cocaine, cannabinoids, street drugs, street amphetamines, and opiates) and medicinal drugs (prescription and over-the-counter). RESULTS 10.5% of nondrinking drivers were using illegal drugs, and 26 to 33% of drivers with illegal BrACs (≥.08 g/dL) were using illegal drugs. Medicinal drug use was more common among nondrinking drivers (4.0%) than among drivers with illegal BrACs (2.4%). CONCLUSIONS The significant relationship between an illegal BrAC and the prevalence of an illegal drug suggests as many as 350,000 illegal drug-using drivers are arrested each year for DWI by U.S. alcohol-impaired driving enforcement. These drug-using drivers need to be identified and appropriate sanctions/treatment programs implemented for them in efforts to extend per se laws to unapprehended drug users. PMID:23265090
Peruzzo, Daiane Cristina; Salvador, Sérgio Luis; Sallum, Antonio Wilson; da Nogueira-Filho, Getúlio Rocha
2008-10-01
The purpose of the present investigation was to evaluate the effects of sodium lauryl sulphate (SLS), present in a commercial dentifrice, on the formation of volatile sulphur compounds (VSC) and tongue coating in a panel of periodontally healthy subjects. A two-step blinded, crossover, randomized study was carried out in 25 dental students with healthy periodontium; these were divided into two experimental groups: SLS (dentifrice with SLS) and WSLS (dentifrice without SLS). The volunteers received the designated dentifrice and a new toothbrush for a 3x/day brushing regimen for 2 periods of 30 days. A seven-day washout interval was used between the periods. The assessed parameters were: plaque index (PI), gingival index (GI), organoleptic breath (ORG), VSC levels by portable sulphide monitor before (H1) and after (H2) cleaning of the tongue, tongue coating wet weight (TC) and benzoyl-DL-arginine-naphthylamide (BANA) test from tongue coating samples. The intra-group analysis showed a decrease in the median of organoleptic scores from 3 to 2 after 30 days for the SLS group (p < 0.05). The inter-group analysis showed lower values in ORG and H1 for the SLS group (p < 0.05). There was no difference between the amount of TC in SLS and WSLS groups. In the BANA test, the presence of SLS did not affect the BANA number of +/- results (p > 0.05). These findings suggest that sodium lauryl sulphate (SLS), present in dentifrice, appears to prevent VSC formation in morning bad breath regardless of the amount of tongue coating in periodontally healthy subjects.
NASA Astrophysics Data System (ADS)
Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram
2016-06-01
Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange.
Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram
2016-01-01
Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange. PMID:27311826
Non-absorbable antibiotics for managing intestinal gas production and gas-related symptoms.
Di Stefano, M; Strocchi, A; Malservisi, S; Veneto, G; Ferrieri, A; Corazza, G R
2000-08-01
Simethicone, activated charcoal and antimicrobial drugs have been used to treat gas-related symptoms with conflicting results. To study the relationship between gaseous symptoms and colonic gas production and to test the efficacy of rifaximin, a new non-absorbable antimicrobial agent, on these symptoms. Intestinal gas production was measured by hydrogen (H2) and methane (CH4) breath testing after lactulose in 21 healthy volunteers and 34 functional patients. Only the 34 functional patients took part in a double-blind, double-dummy controlled trial, receiving, at random, rifaximin (400 mg b.d per 7 days), or activated charcoal (400 mg b.d per 7 days). The following parameters were evaluated at the start of the study and 1 and 10 days after therapy: bloating, abdominal pain, number of flatus episodes, abdominal girth, and cumulative breath H2 excretion. Hydrogen excretion was greater in functional patients than in healthy volunteers. Rifaximin, but not activated charcoal, led to a significant reduction in H2 excretion and overall severity of symptoms. In particular, in patients treated with rifaximin, a significant reduction in the mean number of flatus episodes and of mean abdominal girth was evident. In patients with gas-related symptoms the colonic production of H2 is increased. Rifaximin significantly reduces this production and the excessive number of flatus episodes.
Increased Prevalence of Sleep-Disordered Breathing in Adults
Peppard, Paul E.; Young, Terry; Barnet, Jodi H.; Palta, Mari; Hagen, Erika W.; Hla, Khin Mae
2013-01-01
Sleep-disordered breathing is a common disorder with a range of harmful sequelae. Obesity is a strong causal factor for sleep-disordered breathing, and because of the ongoing obesity epidemic, previous estimates of sleep-disordered breathing prevalence require updating. We estimated the prevalence of sleep-disordered breathing in the United States for the periods of 1988–1994 and 2007–2010 using data from the Wisconsin Sleep Cohort Study, an ongoing community-based study that was established in 1988 with participants randomly selected from an employed population of Wisconsin adults. A total of 1,520 participants who were 30–70 years of age had baseline polysomnography studies to assess the presence of sleep-disordered breathing. Participants were invited for repeat studies at 4-year intervals. The prevalence of sleep-disordered breathing was modeled as a function of age, sex, and body mass index, and estimates were extrapolated to US body mass index distributions estimated using data from the National Health and Nutrition Examination Survey. The current prevalence estimates of moderate to severe sleep-disordered breathing (apnea-hypopnea index, measured as events/hour, ≥15) are 10% (95% confidence interval (CI): 7, 12) among 30–49-year-old men; 17% (95% CI: 15, 21) among 50–70-year-old men; 3% (95% CI: 2, 4) among 30–49-year-old women; and 9% (95% CI: 7, 11) among 50–70 year-old women. These estimated prevalence rates represent substantial increases over the last 2 decades (relative increases of between 14% and 55% depending on the subgroup). PMID:23589584
Khaleghipour, Shahnaz; Masjedi, Mohsen; Kelishadi, Roya
2013-01-01
Background The nocturnal enuresis is one of the most common complaints of childhood. Upper airway obstruction and nocturnal snoring affect the nocturnal enuresis in children. Objectives The aim of this study was to investigate the effects of breathing exercises on the nocturnal enuresis in the children with the sleep-disordered breathing. Patients and Methods This study was conducted in year of 2011 by a semi-experimental design with the control group among 40 children, aged 6 - 12 years, who had the nocturnal enuresis. Participants were examined based on the criteria of nocturnal enuresis, oral breathing, and nocturnal snoring. Subsequently, they were randomly assigned to the case and control groups. In the case group, the breathing exercises were performed for 45 minutes, and were pursued for four weeks in the morning following and prior to sleeping, and subsequently the arterial blood gases were measured and the frequency of enuresis and the respiratory rates (RR) were recorded. Results After intervention the means of PaCO2 and RR in the control group were significantly higher than the case group (P < 0.0001). Likewise, O2sat, PaO2 in the case group were higher than the control group (P < 0.0001). The nocturnal enuresis decreased significantly in the case group, compared to the control group (P < 0.0001). Conclusions This study suggests that the breathing exercises may reduce the frequency of nocturnal enuresis in the patients with the oral breathing and nocturnal snore. The clinical implications of these findings should be verified in the future longitudinal studies. PMID:24719691
Jones, Alan Wayne; Andersson, Lars
2008-06-01
The analysis of ethanol in exhaled breath is widely accepted and used worldwide for legal purposes to gather evidence of alcohol-impaired driving. Most evidential breath-alcohol instruments incorporate infrared (IR) spectroscopy as the analytical principle focusing on C-H or C-O stretching frequencies in ethanol molecules. The instrument approved for legal purposes in Sweden is called Evidenzer and is equipped with five infrared filters of which four are used for identification and quantification of ethanol and the fifth is a reference filter. The response of Evidenzer was tested against 21 volatile organic compounds (VOCs), and the instrument was programmed to deduct any bias caused by these VOCs if present in a sample of breath. If the amount deducted exceeds a certain threshold value, the entire test is aborted. Whenever this happens, the police request a specimen of venous blood for analysis by gas chromatography. Of a total of 24 072 drunken drivers, the evidential breath-alcohol test was aborted on 27 occasions (0.11%) because an interfering substance was present above the critical threshold. The VOCs most commonly identified in blood were acetone, isopropanol and/or methyl ethyl ketone (MEK). Elevated levels of acetone and isopropanol might arise during ketogenesis in people suffering from diabetes, or in those who eat low carbohydrate diets. High concentrations of acetone and MEK are probably caused by people drinking a technical alcohol product (T-Red), which is available in Sweden and is denatured with these agents. This study confirms that relatively few apprehended drivers in Sweden have elevated concentrations of VOCs in breath other than ethanol. Even the aborted breath tests, to a large extent, contained ethanol above the legal limit for driving.
Baarends, E M; Schols, A M; Nusmeier, C M; van der Grinten, C P; Wouters, E F
1998-05-01
Patients with chronic obstructive pulmonary disease (COPD) demonstrate an increased oxygen cost of breathing. It is as yet unclear whether this is related to a decreased breathing efficiency. The aim of the present study was to compare breathing efficiency in 16 patients with COPD (11 men, five women) and 16 healthy elderly subjects (seven men, nine women), and to investigate a possible relationship between breathing efficiency and resting energy expenditure (REE). REE was measured using a ventilated hood system. Breathing efficiency was assessed by measuring oxygen consumption (V'O2), mean inspiratory mouth pressure (MIP) and flow during breathing at rest and subsequently during breathing against an inspiratory threshold (40% of maximal inspiratory pressure). During loaded breathing there was a significant increase in V'O2, MIP, and external work of breathing compared with unloaded breathing in both groups. As intended, ventilation did not increase significantly during the breathing efficiency test in the patients with COPD. The breathing efficiency (median, range) of the patients with COPD was similar (3.7%, 1.4-8.7%) to that of the healthy elderly subjects (3.2%, 1.7-8.3%). Breathing efficiency was not correlated with REE in either group. In the present study, in which dynamic hyperinflation was probably prevented, no difference in breathing efficiency was found between healthy elderly subjects and COPD patients when breathing against an external inspiratory threshold. Furthermore, breathing efficiency was not related to REE in both groups.
Breath test refusals and DWI prosecution : traffic tech.
DOT National Transportation Integrated Search
2012-08-01
There are typically about 1.4 million DWI (driving while : impaired) arrests each year in the United States. An officers : request to a driver for a breath (or blood, or urine) test is an : important part of the arrest process. The percentage of d...
A visual stethoscope to detect the position of the tracheal tube.
Kato, Hiromi; Suzuki, Akira; Nakajima, Yoshiki; Makino, Hiroshi; Sanjo, Yoshimitsu; Nakai, Takayoshi; Shiraishi, Yoshito; Katoh, Takasumi; Sato, Shigehito
2009-12-01
Advancing a tracheal tube into the bronchus produces unilateral breath sounds. We created a Visual Stethoscope that allows real-time fast Fourier transformation of the sound signal and 3-dimensional (frequency-amplitude-time) color rendering of the results on a personal computer with simultaneous processing of 2 individual sound signals. The aim of this study was to evaluate whether the Visual Stethoscope can detect bronchial intubation in comparison with auscultation. After induction of general anesthesia, the trachea was intubated with a tracheal tube. The distance from the incisors to the carina was measured using a fiberoptic bronchoscope. While the anesthesiologist advanced the tracheal tube from the trachea to the bronchus, another anesthesiologist auscultated breath sounds to detect changes of the breath sounds and/or disappearance of bilateral breath sounds for every 1 cm that the tracheal tube was advanced. Two precordial stethoscopes placed at the left and right sides of the chest were used to record breath sounds simultaneously. Subsequently, at a later date, we randomly entered the recorded breath sounds into the Visual Stethoscope. The same anesthesiologist observed the visualized breath sounds on the personal computer screen processed by the Visual Stethoscope to examine changes of breath sounds and/or disappearance of bilateral breath sound. We compared the decision made based on auscultation with that made based on the results of the visualized breath sounds using the Visual Stethoscope. Thirty patients were enrolled in the study. When irregular breath sounds were auscultated, the tip of the tracheal tube was located at 0.6 +/- 1.2 cm on the bronchial side of the carina. Using the Visual Stethoscope, when there were any changes of the shape of the visualized breath sound, the tube was located at 0.4 +/- 0.8 cm on the tracheal side of the carina (P < 0.01). When unilateral breath sounds were auscultated, the tube was located at 2.6 +/- 1.2 cm on the bronchial side of the carina. The tube was also located at 2.3 +/- 1.0 cm on the bronchial side of the carina when a unilateral shape of visualized breath sounds was obtained using the Visual Stethoscope (not significant). During advancement of the tracheal tube, alterations of the shape of the visualized breath sounds using the Visual Stethoscope appeared before the changes of the breath sounds were detected by auscultation. Bilateral breath sounds disappeared when the tip of the tracheal tube was advanced beyond the carina in both groups.
42 CFR 84.95 - Service time test; open-circuit apparatus.
Code of Federal Regulations, 2013 CFR
2013-10-01
... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2013-10-01 2013-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...
42 CFR 84.95 - Service time test; open-circuit apparatus.
Code of Federal Regulations, 2012 CFR
2012-10-01
... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2012-10-01 2012-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...
42 CFR 84.95 - Service time test; open-circuit apparatus.
Code of Federal Regulations, 2014 CFR
2014-10-01
... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2014-10-01 2014-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...
42 CFR 84.95 - Service time test; open-circuit apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be measured with a breathing machine as described in § 84.88. (b) The open-circuit apparatus will be...
42 CFR 84.95 - Service time test; open-circuit apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be measured with a breathing machine as described in § 84.88. (b) The open-circuit apparatus will be...
Sleep Disordered Breathing in Patients with Heart Failure: Pathophysiology and Management
Sharma, Bhavneesh; McSharry, David; Malhotra, Atul
2013-01-01
Opinion statement Sleep disordered breathing (SDB) is common in heart failure patients across the range of ejection fractions and is associated with adverse prognosis. Although effective pharmacologic and device-based treatment of heart failure may reduce the frequency or severity of SDB, heart failure treatment alone may not be adequate to restore normal breathing during sleep. Continuous positive airway pressure (CPAP) is the major treatment for SDB in heart failure, especially if obstructive rather than central sleep apnea (CSA) predominates. Adequate suppression of CSA by PAP is associated with a heart transplant-free survival benefit, although randomized trials are ongoing. Bilevel PAP (BPAP) may be as effective as CPAP in treating SDB and may be preferable over CPAP in patients who experience expiratory pressure discomfort. Adaptive (or auto) servo-ventilation (ASV), which adjusts the PAP depending on the patient’s airflow or tidal volume, may be useful in congestive heart failure patients if CPAP is ineffective. Other therapies that have been proposed for SDB in congestive heart failure include nocturnal oxygen, CO2 administration (by adding dead space), theophylline, and acetazolamide; most of which have not been systematically studied in outcome-based prospective randomized trials. PMID:21894522
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements.
Wang, Zhennan; Wang, Chuji
2013-09-01
Since the ancient discovery of the 'sweet odor' in human breath gas, pursuits of the breath analysis-based disease diagnostics have never stopped. Actually, the 'smell' of the breath, as one of three key disease diagnostic techniques, has been used in Eastern-Medicine for more than three thousand years. With advancement of measuring technologies in sensitivity and selectivity, more specific breath gas species have been identified and established as a biomarker of a particular disease. Acetone is one of the breath gases and its concentration in exhaled breath can now be determined with high accuracy using various techniques and methods. With the worldwide prevalence of diabetes that is typically diagnosed through blood testing, human desire to achieve non-blood based diabetic diagnostics and monitoring has never been quenched. Questions, such as is breath acetone a biomarker of diabetes and how is the breath acetone related to the blood glucose (BG) level (the golden criterion currently used in clinic for diabetes diagnostic, monitoring, and management), remain to be answered. A majority of current research efforts in breath acetone measurements and its technology developments focus on addressing the first question. The effort to tackle the second question has begun recently. The earliest breath acetone measurement in clearly defined diabetic patients was reported more than 60 years ago. For more than a half-century, as reviewed in this paper, there have been more than 41 independent studies of breath acetone using various techniques and methods, and more than 3211 human subjects, including 1581 healthy people, 242 Type 1 diabetic patients, 384 Type 2 diabetic patients, 174 unspecified diabetic patients, and 830 non-diabetic patients or healthy subjects who are under various physiological conditions, have been used in the studies. The results of the breath acetone measurements collected in this review support that many conditions might cause changes to breath acetone concentrations; however, the results from the six independent studies using clearly-defined Type 1 and Type 2 diabetic patients unanimously support that an elevated mean breath acetone concentration exists in Type 1 diabetes. Note that there is some overlap between the ranges of breath acetone concentration in individual T1D patients and healthy subjects; this reminds one to be careful when using an acetone breath test on T1D diagnostics. Comparatively, it is too early to draw a general conclusion on the relationship between a breath acetone level and a BG level from the very limited data in the literature.
Analysis of Exhaled Breath for Disease Detection
NASA Astrophysics Data System (ADS)
Amann, Anton; Miekisch, Wolfram; Schubert, Jochen; Buszewski, Bogusław; Ligor, Tomasz; Jezierski, Tadeusz; Pleil, Joachim; Risby, Terence
2014-06-01
Breath analysis is a young field of research with great clinical potential. As a result of this interest, researchers have developed new analytical techniques that permit real-time analysis of exhaled breath with breath-to-breath resolution in addition to the conventional central laboratory methods using gas chromatography-mass spectrometry. Breath tests are based on endogenously produced volatiles, metabolites of ingested precursors, metabolites produced by bacteria in the gut or the airways, or volatiles appearing after environmental exposure. The composition of exhaled breath may contain valuable information for patients presenting with asthma, renal and liver diseases, lung cancer, chronic obstructive pulmonary disease, inflammatory lung disease, or metabolic disorders. In addition, oxidative stress status may be monitored via volatile products of lipid peroxidation. Measurement of enzyme activity provides phenotypic information important in personalized medicine, whereas breath measurements provide insight into perturbations of the human exposome and can be interpreted as preclinical signals of adverse outcome pathways.
Gender Difference of Gastric Emptying in Healthy Volunteers and Patients with Functional Dyspepsia.
Mori, Hideki; Suzuki, Hidekazu; Matsuzaki, Juntaro; Taniguchi, Kanami; Shimizu, Toshiyuki; Yamane, Tsuyoshi; Masaoka, Tatsuhiro; Kanai, Takanori
2017-01-01
Delayed gastric emptying is one of the reasons why functional dyspepsia (FD) occurs. The 13C-acetate breath test is widely used to evaluate gastric emptying. Nevertheless, the standard value of 13C-acetate breath test has not taken into account the gender difference of gastric emptying among healthy individuals. The main aim of this study was to readjust the standard value of 13C-acetate breath test in the light of gender differences. In addition, we clarified the prevalence and clinical characteristics of delayed gastric emptying in patients with FD using the modified standard values of 13C-acetate breath test. Fifty-two healthy individuals and 126 patients with patients with FD were enrolled. Gastric emptying was evaluated by the 13C-acetate breath test. The cut-off points of Tmax for the diagnosis of delayed gastric emptying were determined on the basis of results from healthy individuals making a distinction of genders. Gastroesophageal reflux symptoms, dyspeptic symptoms, scores of anxiety and depression, age, body mass index (BMI), smoking and alcohol consumption were compared between the delayed gastric emptying group and the non-delayed gastric emptying group. Since gastric emptying was delayed in healthy women compared with that in healthy men (Tmax, 53.6 ± 19.3 vs. 42.7 ± 16.9 min, p = 0.04), we set the cut-off points of Tmax at 60 min in men and at 75 min in women. In patients with FD, the prevalence of delayed gastric emptying was not different between men and women with the modified standard values of 13C-acetate breath test. (31.0 vs. 27.4%, p = 0.68). BMI was lower in the delayed gastric emptying group than in the non-delayed group among the male patients. Reflux symptoms were more severe in delayed gastric emptying group than in the non-delayed group among the female patients. The standard values of 13C-acetate breath test should be modified bearing the gender difference in mind. It provides us more appropriate information to understand the mechanisms of FD. © 2016 S. Karger AG, Basel.
Hay, Greg; Cercarelli, L Rina
2004-04-01
To examine the accuracy of coin-operated breath analysers installed in licensed premises in the Perth metropolitan area. Two hundred licensed premises were contacted, which resulted in the location of 36 wall-mounted, coin-operated breath analysers. One instrument was removed prior to testing. These premises were then visited and the accuracy of the instruments was tested in situ using National Association of Testing Authorities Australia (NATA) certified 0.080% and 0.100% ethanol in nitrogen gas. The instruments were installed in the licensed premises as follows: 15 in the lounge bar, 10 in the main entrance, six in the public bar, two in the passageway to the toilets, and one in the male toilets. One licensed premise provided a handheld breath instrument. All instruments were accompanied by warning and operating instructions, but only five had any educational material. Only seven of the licensed premises had staff who had received any training in the operation of the wall-mounted instruments. Half of the licensees were unaware of the servicing requirements of the instruments. The testing found that only nine (25%) of the instruments provided acceptable results. The low level of accuracy of coin-operated breath analysers in the Perth metropolitan area is alarming and users should be informed of the potential inaccuracies. This paper, however, does not rule out that some wall-mounted breath analysing instruments may provide accurate results when properly maintained.
Use of the single-breath method of estimating cardiac output during exercise-stress testing.
NASA Technical Reports Server (NTRS)
Buderer, M. C.; Rummel, J. A.; Sawin, C. F.; Mauldin, D. G.
1973-01-01
The single-breath cardiac output measurement technique of Kim et al. (1966) has been modified for use in obtaining cardiac output measurements during exercise-stress tests on Apollo astronauts. The modifications involve the use of a respiratory mass spectrometer for data acquisition and a digital computer program for data analysis. The variation of the modified method for triplicate steady-state cardiac output measurements was plus or minus 1 liter/min. The combined physiological and methodological variation seen during a set of three exercise tests on a series of subjects was 1 to 2.5 liter/min. Comparison of the modified method with the direct Fick technique showed that although the single-breath values were consistently low, the scatter of data was small and the correlation between the two methods was high. Possible reasons for the low single-breath cardiac output values are discussed.
Celhay, Isabel; Cordova, Rosa; Miralles, Rodolfo; Meza, Francisco; Erices, Pia; Barrientos, Camilo; Valenzuela, Saúl
2015-04-01
To compare electromyographic (EMG) activity in young-adult subjects with different breathing types. This study included 50 healthy male subjects with complete natural dentition, and no history of orofacial pain or craniomandibular-cervical-spinal disorders. Subjects were classified into two groups: upper costal breathing type, and costo-diaphragmatic breathing. Bipolar surface electrodes were located on sternocleidomastoid, diaphragm, external intercostal, and latissimus dorsi muscles. Electromyographic activity was recorded during the following tasks: (1) normal quiet breathing; (2) speaking the word 'Mississippi'; (3) swallowing saliva; and (4) forced deep breathing. Sternocleidomastoid and latissimus dorsi EMG activity was not significantly different between breathing types, whereas diaphragm and external intercostal EMG activity was significantly higher in the upper costal than costo-diaphragmatic breathing type in all tasks (P<0·05; Wilcoxon signed rank-sum test). Diaphragm and external intercostal EMG activity suggests that there could be differences in motor unit recruitment strategies depending on the breathing type.
Sano, Masahiro; Sano, Sayaka; Oka, Noriyuki; Yoshino, Kayoko; Kato, Toshinori
2013-12-04
Individuals who habitually breathe through the mouth are more likely than nasal breathers to have sleep disorders and attention deficit hyperactive disorder. We hypothesized that brain hemodynamic responses in the prefrontal cortex might be different for mouth and nasal breathing. To test this hypothesis, we measured changes in oxyhemoglobin and deoxyhemoglobin in the prefrontal cortex during mouth breathing and nasal breathing in healthy adults (n=9) using vector-based near-infrared spectroscopy. The angle k, calculated from changes in oxyhemoglobin and deoxyhemoglobin and indicating the degree of oxygen exchange, was significantly higher during mouth breathing (P<0.05), indicating an increased oxygen load. Mouth breathing also caused a significant increase in deoxyhemoglobin, but oxyhemoglobin did not increase. This difference in oxygen load in the brain arising from different breathing routes can be evaluated quantitatively using vector-based near-infrared spectroscopy. Phase responses could help to provide an earlier and more reliable diagnosis of a patient's habitual breathing route than a patient interview.
Sano, Sayaka; Oka, Noriyuki; Yoshino, Kayoko; Kato, Toshinori
2013-01-01
Individuals who habitually breathe through the mouth are more likely than nasal breathers to have sleep disorders and attention deficit hyperactive disorder. We hypothesized that brain hemodynamic responses in the prefrontal cortex might be different for mouth and nasal breathing. To test this hypothesis, we measured changes in oxyhemoglobin and deoxyhemoglobin in the prefrontal cortex during mouth breathing and nasal breathing in healthy adults (n=9) using vector-based near-infrared spectroscopy. The angle k, calculated from changes in oxyhemoglobin and deoxyhemoglobin and indicating the degree of oxygen exchange, was significantly higher during mouth breathing (P<0.05), indicating an increased oxygen load. Mouth breathing also caused a significant increase in deoxyhemoglobin, but oxyhemoglobin did not increase. This difference in oxygen load in the brain arising from different breathing routes can be evaluated quantitatively using vector-based near-infrared spectroscopy. Phase responses could help to provide an earlier and more reliable diagnosis of a patient’s habitual breathing route than a patient interview. PMID:24169579
Automatic Recognition of Breathing Route During Sleep Using Snoring Sounds
NASA Astrophysics Data System (ADS)
Mikami, Tsuyoshi; Kojima, Yohichiro
This letter classifies snoring sounds into three breathing routes (oral, nasal, and oronasal) with discriminant analysis of the power spectra and k-nearest neighbor method. It is necessary to recognize breathing route during snoring, because oral snoring is a typical symptom of sleep apnea but we cannot know our own breathing and snoring condition during sleep. As a result, about 98.8% classification rate is obtained by using leave-one-out test for performance evaluation.
NASA Astrophysics Data System (ADS)
Erofeev, A. I.; Nikiforov, A. P.; Popov, G. A.; Suvorov, M. O.; Syrin, S. A.; Khartov, S. A.
2017-12-01
Problems on designing the air-breathing ramjet electric propulsion thruster for controlling loworbit spacecraft motion are examined in the paper. Information for choosing orbits' altitudes for reasonable application of an air-breathing ramjet electric propulsion thruster and propellant exhaust velocity is presented. Estimates of the probable increase of gas concentration in the area of air-breathing ramjet ionization are presented. The test results of the thruster are also given.
Yang, Jianfeng; Deng, Yanyong; Chu, Hua; Cong, Yanqun; Zhao, Jianmin; Pohl, Daniel; Misselwitz, Benjamin; Fried, Michael; Dai, Ning; Fox, Mark
2013-03-01
The effects of lactase deficiency on digestive symptoms and diet in patients with irritable bowel syndrome (IBS) have not been well defined. We assessed lactose absorption and tolerance and the intake of dairy products in healthy volunteers (controls) and patients with diarrhea-predominant IBS (D-IBS). Sixty patients diagnosed with D-IBS at the Sir Run Run Shaw Hospital, Hangzhou, China and 60 controls were given hydrogen breath tests to detect malabsorption and intolerance after administration of 10, 20, and 40 g lactose in random order 7-14 days apart; participants and researchers were blinded to the dose. We assessed associations between the results and self-reported lactose intolerance (LI). Malabsorption of 40 g lactose was observed in 93% of controls and 92% of patients with D-IBS. Fewer controls than patients with D-IBS were intolerant to 10 g lactose (3% vs 18%; odds ratio [OR], 6.51; 95% confidence interval [CI], 1.38-30.8; P = .008), 20 g lactose (22% vs 47%; OR, 3.16; 95% CI, 1.43-7.02; P = .004), and 40 g lactose (68% vs 85%; OR, 2.63; 95% CI, 1.08-6.42; P = .03). H(2) excretion was associated with symptom score (P = .001). Patients with D-IBS self-reported LI more frequently than controls (63% vs 22%; OR, 6.25; 95% CI, 2.78-14.0; P < .001) and ate fewer dairy products (P = .040). However, self-reported LI did not correlate with results from hydrogen breath tests. The risk of LI is related to the dose of lactose ingested and intestinal gas production and is increased in patients with D-IBS. Self-reported LI, but not objective results from hydrogen breath tests, was associated with avoidance of dairy products. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.
Kasicka-Jonderko, A; Jonderko, K; Gajek, E; Piekielniak, A; Zawislan, R
2014-02-01
To study the movement along the gut and the effect upon the gallbladder volume of alcoholic beverages taken in the interdigestive state. The study comprised three research blocks attended by 12 healthy subjects each. Within a given research block volunteers underwent three examination sessions held on separate days, being offered an alcoholic beverage, or an aqueous ethanol solution of an identical proof, or a corresponding volume of isotonic glucose solution; the order of administration of the drinks was randomized. The beverages tested were: beer (4.7% vol, 400 ml), red wine (13.7% vol, 200 ml), whisky (43.5% vol, 100 ml) within the "Beer", "Wine", and "Whisky" research block, respectively. Gastric myoelectrical activity was examined electrogastrographically, gastric emptying with ¹³C-sodium acetate breath test, orocaecal transit with lactulose H₂ breath test, gallbladder emptying with ultrasonography, breath ethanol with alcotest. The study showed that alcoholic beverages were emptied from the stomach significantly slower than isotonic glucose. Alcoholic beverages produced by fermentation only (beer, red wine) were emptied from the stomach more slowly than ethanol solutions of identical proof, while gastric evacuation of whisky (distillation product) and matching alcohol solution was similar. The slower gastric evacuation of alcoholic beverages and ethanol solutions could not be ascribed to a disorganization of the gastric myoelectrical activity. The orocaecal transit of beer and red wine did not differ from that of isotonic glucose, whereas the orocaecal transit of whisky and high proof ethanol was markedly prolonged. Red wine and whisky, and to a similar extent control ethanol solutions caused an inhibition and delay of gallbladder emptying. We concluded that alcoholic beverages taken on an empty stomach exert a suppressive effect upon the transport function of the digestive tract and gallbladder emptying. The extent of this action depends on the type of a beverage (whether it is obtained from fermentation only, or fermentation followed by distillation) and ethanol concentration therein.
DOT National Transportation Integrated Search
1987-03-01
Breath Alcohol Testing (BAT) programs in Albuquerque and Santa Fe, New Mexico are evaluated in regard to effectiveness, impact, and transferability of the special DWI enforcement squads and their use of BAT Mobiles. Squad activity effectiveness is me...
Quality of Life and Obstructive Sleep Apnea Symptoms After Pediatric Adenotonsillectomy
Mitchell, Ron B.; Parker, Portia D.; Moore, Reneé H.; Rosen, Carol L.; Giordani, Bruno; Muzumdar, Hiren; Paruthi, Shalini; Elden, Lisa; Willging, Paul; Beebe, Dean W.; Marcus, Carole L.; Chervin, Ronald D.; Redline, Susan
2015-01-01
BACKGROUND AND OBJECTIVES: Data from a randomized, controlled study of adenotonsillectomy for obstructive sleep apnea syndrome (OSAS) were used to test the hypothesis that children undergoing surgery had greater quality of life (QoL) and symptom improvement than control subjects. The objectives were to compare changes in validated QoL and symptom measurements among children randomized to undergo adenotonsillectomy or watchful waiting; to determine whether race, weight, or baseline OSAS severity influenced changes in QoL and symptoms; and to evaluate associations between changes in QoL or symptoms and OSAS severity. METHODS: Children aged 5 to 9.9 years with OSAS (N = 453) were randomly assigned to undergo adenotonsillectomy or watchful waiting with supportive care. Polysomnography, the Pediatric Quality of Life inventory, the Sleep-Related Breathing Scale of the Pediatric Sleep Questionnaire, the 18-item Obstructive Sleep Apnea QoL instrument, and the modified Epworth Sleepiness Scale were completed at baseline and 7 months. Changes in the QoL and symptom surveys were compared between arms. Effect modification according to race and obesity and associations between changes in polysomnographic measures and QoL or symptoms were examined. RESULTS: Greater improvements in most QoL and symptom severity measurements were observed in children randomized to undergo adenotonsillectomy, including the parent-completed Pediatric Quality of Life inventory (effect size [ES]: 0.37), the 18-item Obstructive Sleep Apnea QoL instrument (ES: –0.93), the modified Epworth Sleepiness Scale score (ES: –0.42), and the Sleep-Related Breathing Scale of the Pediatric Sleep Questionnaire (ES: –1.35). Effect modification was not observed by obesity or baseline severity but was noted for race in some symptom measures. Improvements in OSAS severity explained only a small portion of the observed changes. CONCLUSIONS: Adenotonsillectomy compared with watchful waiting resulted in significantly more improvements in parent-rated generic and OSAS-specific QoL measures and OSAS symptoms. PMID:25601979
Scheenstra, Renske J; Muller, Sara H; Vincent, Andrew; Hilgers, Frans J M
2011-01-01
The aim of this study was to assess the heat and moisture exchange (HME) capacity of the upper respiratory tract and the effect of tracheotomy breathing on endotracheal climate in patients with head and neck cancer. We plotted the subglottic temperature and humidity measurements in 10 patients with head and neck cancer with a temporary precautionary tracheotomy during successive 10-minute periods of nose, mouth, and tracheotomy breathing in a randomized sequence. End-inspiratory temperatures of nose, mouth, and tracheotomy breathing were 31.1, 31.3, and 28.3°C, respectively. End-inspiratory humidity measurements of nose, mouth, and tracheotomy breathing were 29.3, 28.6, and 21.1 mgH₂O/L, respectively. There was a trend toward lower end-inspiratory humidity in patients with radiotherapy or with large surgery-induced oropharyngeal mucosal defects, whereas temperatures were similar. This study gives objective information about the HME capacity of the upper respiratory tract in patients with head and neck cancer with precautionary tracheotomy, and thus provides target values for HMEs for laryngectomized and tracheotomized patients. © 2010 Wiley Periodicals, Inc. Head Neck, 2011.
Performance of acidified 14C-urea capsule breath test during pantoprazole and ranitidine treatment.
Oztürk, Emel; Yeşilova, Zeki; Ilgan, Seyfettin; Ozgüven, Mehmet; Dağalp, Kemal
2009-07-01
Urea breath test (UBT) results could be false negative in patients taking antisecretory drugs. This effect would be prevented by citric acid administration during UBT. We prospectively investigated whether acidified 14C-urea capsule prevents false negative UBT results in patients taking antisecretory drugs and show interference with the duration of medications. Sixty Helicobacter pylori positive patients were included. Pantoprazole (40 mg/day) was given to 27 patients for 28 days and ranitidine (300 mg. o.d.) to 33 patients for 60 days. Urea breath tests were repeated on days 14 and 28 in both groups and on day 60 in the ranitidine group. The baseline mean breath counts of two groups did not show any significant difference. Pantoprazole led to a significant decrease in mean breath counts on day 14 (P < 0.005). Six of 27 and 3 of 25 patients taking pantoprazole developed negative or equivocal UBT results on days 14 and 28, respectively. Two of 32, 2 of 32 and 3 of 21 patients taking ranitidine developed negative or equivocal UBT results on days 14, 28 and 60, respectively. The use of acidified 14C-urea capsule did not prevent false negative UBT results in patients taking pantoprazole and ranitidine, and the duration of medication does not affect the test results.
Storer, Malina; Salmond, Jennifer; Dirks, Kim N; Kingham, Simon; Epton, Michael
2014-09-01
Studies of health effects of air pollution exposure are limited by inability to accurately determine dose and exposure of air pollution in field trials. We explored the feasibility of using a mobile selected ion flow tube mass spectrometry (SIFT-MS) device, housed in a van, to determine ambient air and breath levels of benzene, xylene and toluene following exercise in areas of high motor vehicle traffic. The breath toluene, xylene and benzene concentration of healthy subjects were measured before and after exercising close to a busy road. The concentration of the volatile organic compounds (VOCs), in ambient air were also analysed in real time. Exercise close to traffic pollution is associated with a two-fold increase in breath VOCs (benzene, xylene and toluene) with levels returning to baseline within 20 min. This effect is not seen when exercising away from traffic pollution sources. Situating the testing device 50 m from the road reduced any confounding due to VOCs in the inspired air prior to the breath testing manoeuvre itself. Real-time field testing for air pollution exposure is possible using a mobile SIFT-MS device. This device is suitable for exploring exposure and dose relationships in a number of large scale field test scenarios.
Norlander, Katarina; Johansson, Henrik; Jansson, Christer; Nordvall, Lennart; Nordang, Leif
2015-01-01
Surgery is an effective treatment in severe cases of supraglottic exercise-induced laryngeal obstruction (E-ILO). Conservatively treated subjects and subjects tested negative for E-ILO, who still experience breathing problems 1-3 years after diagnosis, tend to adjust their physical activity to a greater extent than surgically treated subjects. To investigate how symptoms and level of physical activity change over time in patients with E-ILO who have undergone surgery, patients with E-ILO treated conservatively and patients who tested negative for laryngeal obstruction at continuous laryngoscopy exercise-test (CLE-test). Patients referred for exercise-induced breathing difficulties answered questionnaires at diagnostic CLE-test and at follow-up. Questions regarded exercise-induced breathing problems, current physical activity level, and medical history of asthma and perennial allergy. Out of 84 invited subjects, 59 (70%) answered both questionnaires. Surgically treated subjects had less breathing problems at follow-up compared with conservatively treated subjects and subjects who tested negative (p < 0.001). None of the surgically treated subjects were less physically active or had changed sport due to exercise-induced dyspnoea, whereas 41.7% of the conservatively treated subjects had made such adjustments (p < 0.001).
Code of Federal Regulations, 2012 CFR
2012-01-01
... special nuclear material based on a drug test, a National Agency Check, a psychological assessment, a... expressed in terms of grams of alcohol per 210 liters of breath as indicated by a breath test. Alcohol use... professional expertise in occupational medicine for the HRP. Designated Psychologist means a licensed Ph.D., or...
Code of Federal Regulations, 2013 CFR
2013-01-01
... special nuclear material based on a drug test, a National Agency Check, a psychological assessment, a... expressed in terms of grams of alcohol per 210 liters of breath as indicated by a breath test. Alcohol use... professional expertise in occupational medicine for the HRP. Designated Psychologist means a licensed Ph.D., or...
USDA-ARS?s Scientific Manuscript database
Congenital sucrase-isomaltase deficiency (CSID) is characterized by absence or deficiency of the mucosal sucrase-isomaltase enzyme. Specific diagnosis requires upper gastrointestinal biopsy with evidence of low to absent sucrase enzyme activity and normal histology. The hydrogen breath test (BT) is ...
77 FR 14167 - Approval Tests and Standards for Closed-Circuit Escape Respirators
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-08
... Dioxide 3. Oxygen 4. Peak Breathing Pressures 5. Wet-Bulb Temperature L. Section 84.304 Capacity Test... oxygen storage or chemical carbon dioxide scrubber can be altered by impact or any other effect must... inhaled carbon dioxide, average inhaled oxygen, peak breathing pressures, and wet-bulb temperature...
42 CFR 84.152 - Breathing tube test; minimum requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
...: (i) Be employed on Type C supplied-air respirators of the demand and pressure-demand class; and (ii... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.152 Breathing tube test; minimum requirements. (a)(1) Type A and Type B supplied-air...
DOT National Transportation Integrated Search
1974-06-01
This evaluation report examines use in the field of portable breath test (PBT) devices by police in Hennepin County, Minnesota. Thirteen Brog-Warner J2 and J2A-200 "ALERT" devices were deployed by seven enforcement agencies. This report is presented ...
... treated. The person may receive: Blood and urine tests. Breathing support, including a tube through the mouth into the lungs, and a breathing machine (ventilator). Chest x-ray. Endoscopy -- camera placed down ...
Exhaled breath analysis for lung cancer
Sutedja, Tom G.; Zimmerman, Paul V.
2013-01-01
Early diagnosis of lung cancer results in improved survival compared to diagnosis with more advanced disease. Early disease is not reliably indicated by symptoms. Because investigations such as bronchoscopy and needle biopsy have associated risks and substantial costs, they are not suitable for population screening. Hence new easily applicable tests, which can be used to screen individuals at risk, are required. Biomarker testing in exhaled breath samples is a simple, relatively inexpensive, non-invasive approach. Exhaled breath contains volatile and non-volatile organic compounds produced as end-products of metabolic processes and the composition of such compounds varies between healthy subjects and subjects with lung cancer. Many studies have analysed the patterns of these compounds in exhaled breath. In addition studies have also reported that the exhaled breath condensate (EBC) can reveal gene mutations or DNA abnormalities in patients with lung cancer. This review has summarised the scientific evidence demonstrating that lung cancer has distinct chemical profiles in exhaled breath and characteristic genetic changes in EBC. It is not yet possible to accurately identify individuals with lung cancer in at risk populations by any of these techniques. However, analysis of both volatile organic compounds in exhaled breath and of EBC have great potential to become clinically useful diagnostic and screening tools for early stage lung cancer detection. PMID:24163746
A chlorate candle/lithium hydroxide personal breathing apparatus
NASA Technical Reports Server (NTRS)
Martin, F. E.
1972-01-01
A portable coal mine rescue and survival equipment is reported that consists of a chlorate candle with a lithium hydroxide carbon-dioxide absorbent for oxygen generation, a breathing bag and tubing to conduct breathing to and from the man. A plastic hood incorporating a mouth piece for communication provides also eye protection and prevents inhalation through the nose. Manned testing of a prototype system demonstrated the feasibility of this closed circuit no-maintenance breathing apparatus that provides for good voice communication.
Breath tests and irritable bowel syndrome
Rana, Satya Vati; Malik, Aastha
2014-01-01
Breath tests are non-invasive tests and can detect H2 and CH4 gases which are produced by bacterial fermentation of unabsorbed intestinal carbohydrate and are excreted in the breath. These tests are used in the diagnosis of carbohydrate malabsorption, small intestinal bacterial overgrowth, and for measuring the orocecal transit time. Malabsorption of carbohydrates is a key trigger of irritable bowel syndrome (IBS)-type symptoms such as diarrhea and/or constipation, bloating, excess flatulence, headaches and lack of energy. Abdominal bloating is a common nonspecific symptom which can negatively impact quality of life. It may reflect dietary imbalance, such as excess fiber intake, or may be a manifestation of IBS. However, bloating may also represent small intestinal bacterial overgrowth. Patients with persistent symptoms of abdominal bloating and distension despite dietary interventions should be referred for H2 breath testing to determine the presence or absence of bacterial overgrowth. If bacterial overgrowth is identified, patients are typically treated with antibiotics. Evaluation of IBS generally includes testing of other disorders that cause similar symptoms. Carbohydrate malabsorption (lactose, fructose, sorbitol) can cause abdominal fullness, bloating, nausea, abdominal pain, flatulence, and diarrhea, which are similar to the symptoms of IBS. However, it is unclear if these digestive disorders contribute to or cause the symptoms of IBS. Research studies show that a proper diagnosis and effective dietary intervention significantly reduces the severity and frequency of gastrointestinal symptoms in IBS. Thus, diagnosis of malabsorption of these carbohydrates in IBS using a breath test is very important to guide the clinician in the proper treatment of IBS patients. PMID:24976698
ERIC Educational Resources Information Center
Reed, Derek D.; Martens, Brian K.
2008-01-01
We describe a clinical case study surrounding the behavioral assessment and operant treatment of, an adult with severe mental retardation who engaged in chronic breath-holding. In this clinical case, previous neurological and medical testing had ruled out biological bases for the individual's breath-holding. A functional behavioral assessment…
Busanello-Stella, Angela Ruviaro; Blanco-Dutra, Ana Paula; Corrêa, Eliane Castilhos Rodrigues; Silva, Ana Maria Toniolo da
2015-01-01
To investigate the process of fatigue in orbicularis oris muscles by analyzing the median frequency of electromyographic signal and the referred fatigue time, according to the breathing mode and the facial pattern. The participants were 70 children, aged 6 to 12 years, who matched the established criteria. To be classified as 36 nasal-breathing and 34 mouth-breathing children, they underwent speech-language, otorhinolaryngologic, and cephalometric evaluation. For the electromyographic assessment, the children had to sustain lip dumbbells weighing 40, 60, and 100 g and a lip exerciser, until the feeling of fatigue. Median frequency was analyzed in 5, 10, 15, and 20 seconds of activity. The referred time of the feeling of fatigue was also recorded. Data were analyzed through the analysis of variance--repeated measures (post hoc Tukey's test), Kruskal-Wallis test, and Mann-Whitney U-test. A significant decrease in the median frequency from 5 seconds of activity was observed, independently from the comparison between the groups. On comparison, the muscles did not show significant decrease. The reported time for the feeling of fatigue was shorter for mouth-breathing individuals. This feeling occurred after the significant decrease in the median frequency. There were signals that indicated myoelectric fatigue for the orbicularis oris muscles, in both groups analyzed, from the first 5 seconds of activity. Myoelectric fatigue in the orbicularis oris muscles preceded the reported feeling of fatigue in all groups. The account for fatigue time was influenced by only the breathing pattern, occurring more precociously in mouth-breathing children.
... treated. The person may receive: Blood and urine tests. Breathing support, including a tube through the mouth into the lungs, and a breathing machine (ventilator). Bronchoscopy -- camera placed down the throat to ...
DOT National Transportation Integrated Search
1975-02-01
Randomly selected drivers were stopped at times and places of previous fatal crashes in Lincoln, Nebraska, and Dade County (Miami), Florida. Breath, urnine, blood, and lip swab samples were requested, for later analysis for drugs and medications. A c...
Effects of Cold Therapy on Pain and Breathing Exercises Among Median Sternotomy Patients.
Zencir, Gülbanu; Eser, Ismet
2016-12-01
The most painful activities during the days following cardiac surgery are coughing and deep breathing exercises. Cold therapy is an effective nonpharmacological method that decreases the pain during coughing and mobilization. In this study, the effects of cold therapy on pain and breathing exercises among patients with median sternotomy following cardiac surgery were investigated in a randomized crossover clinical trial. Data were collected from patients with median sternotomy (N = 34) in the first two postoperative days. Because of the crossover design of the study, each patient was taken as a simultaneous control. Gel pack application was used as the cold therapy. Patients underwent four episodes of deep breathing and coughing exercises using an incentive spirometer (volumetric). Patients were evaluated according to the visual analogue scale for pain intensity before and after deep breathing and coughing exercise sessions. The pain score was 3.44 ± 2.45 at baseline for deep breathing and coughing exercises on the first day. The reported postoperative pain in the gel-pack group was not significantly different before and after the deep breathing and coughing exercises, but it significantly increased in the no-gel-pack group (p < .001). Although the interaction between the treatment and time was significant (partial eta-squared: .09), the gel-pack group had a lower change in average pain levels. This interaction was not significant in terms of spirometric values. In conclusion, cold therapy had a positive effect on pain management in the early period of post-cardiac surgery but was not effective for the pain associated with breathing exercises. Copyright © 2016 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.
Monitoring of rapid blood pH variations by CO detection in breath with tunable diode laser
NASA Astrophysics Data System (ADS)
Kouznetsov, Andrian I.; Stepanov, Eugene V.; Zyrianov, Pavel V.; Shulagin, Yurii A.; Diachenko, Alexander I.; Gurfinkel, Youri I.
1997-06-01
Detection of endogenous carbon monoxide content in breath with tunable diode lasers (TDL) was proposed for noninvasive monitoring of rapid blood pH variation. Applied approach is based on high sensitivity of the haemoglobin and myoglobin affinity for CO to blood pH value and an ability to detect rapidly small variations of CO content in expired air. Breath CO absorption in 4.7 micrometers spectral region was carefully measured using PbSSe tunable diode laser that can provide 1 ppb CO concentration sensitivity and 10 s time constant. Applied TDL gas analyzer was used to monitor expired air of studied persons in physiological tests including hyperventilation and physical load. Simultaneous blood tests were conducted to demonstrate correlation between blood and breath chemical parameters.
Guidelines proposal for clinical recognition of mouth breathing children.
Pacheco, Maria Christina Thomé; Casagrande, Camila Ferreira; Teixeira, Lícia Pacheco; Finck, Nathalia Silveira; de Araújo, Maria Teresa Martins
2015-01-01
Mouth breathing (MB) is an etiological factor for sleep-disordered breathing (SDB) during childhood. The habit of breathing through the mouth may be perpetuated even after airway clearance. Both habit and obstruction may cause facial muscle imbalance and craniofacial changes. The aim of this paper is to propose and test guidelines for clinical recognition of MB and some predisposing factors for SDB in children. Semi-structured interviews were conducted with 110 orthodontists regarding their procedures for clinical evaluation of MB and their knowledge about SDB during childhood. Thereafter, based on their answers, guidelines were developed and tested in 687 children aged between 6 and 12 years old and attending elementary schools. There was no standardization for clinical recognition of MB among orthodontists. The most common procedures performed were inefficient to recognize differences between MB by habit or obstruction. The guidelines proposed herein facilitate clinical recognition of MB, help clinicians to differentiate between habit and obstruction, suggest the most appropriate treatment for each case, and avoid maintenance of mouth breathing patterns during adulthood.
eAMI: A Qualitative Quantification of Periodic Breathing Based on Amplitude of Oscillations
Fernandez Tellez, Helio; Pattyn, Nathalie; Mairesse, Olivier; Dolenc-Groselj, Leja; Eiken, Ola; Mekjavic, Igor B.; Migeotte, P. F.; Macdonald-Nethercott, Eoin; Meeusen, Romain; Neyt, Xavier
2015-01-01
Study Objectives: Periodic breathing is sleep disordered breathing characterized by instability in the respiratory pattern that exhibits an oscillatory behavior. Periodic breathing is associated with increased mortality, and it is observed in a variety of situations, such as acute hypoxia, chronic heart failure, and damage to respiratory centers. The standard quantification for the diagnosis of sleep related breathing disorders is the apnea-hypopnea index (AHI), which measures the proportion of apneic/hypopneic events during polysomnography. Determining the AHI is labor-intensive and requires the simultaneous recording of airflow and oxygen saturation. In this paper, we propose an automated, simple, and novel methodology for the detection and qualification of periodic breathing: the estimated amplitude modulation index (eAMI). Patients or Participants: Antarctic cohort (3,800 meters): 13 normal individuals. Clinical cohort: 39 different patients suffering from diverse sleep-related pathologies. Measurements and Results: When tested in a population with high levels of periodic breathing (Antarctic cohort), eAMI was closely correlated with AHI (r = 0.95, P < 0.001). When tested in the clinical setting, the proposed method was able to detect portions of the signal in which subclinical periodic breathing was validated by an expert (n = 93; accuracy = 0.85). Average eAMI was also correlated with the loop gain for the combined clinical and Antarctica cohorts (r = 0.58, P < 0.001). Conclusions: In terms of quantification and temporal resolution, the eAMI is able to estimate the strength of periodic breathing and the underlying loop gain at any given time within a record. The impaired prognosis associated with periodic breathing makes its automated detection and early diagnosis of clinical relevance. Citation: Fernandez Tellez H, Pattyn N, Mairesse O, Dolenc-Groselj L, Eiken O, Mekjavic IB, Migeotte PF, Macdonald-Nethercott E, Meeusen R, Neyt X. eAMI: a qualitative quantification of periodic breathing based on amplitude of oscillations. SLEEP 2015;38(3):381–389. PMID:25581914
Detection of nitric oxide in exhaled human breath: exercise and resting determinations.
Mantione, Kirk J; Esch, Tobias; Stefano, George B
2007-03-01
Nitric oxide has become a vital indicator of health since many cells produce it constitutively. It is present in exhaled breath and can be measured. A Kiernan NO Breath analyzer (KNB) was used in the present study to determine nitric oxide (NO) levels in exhaled human breath. The KNB was calibrated via measuring NO gas in O2-free N2 obtained from Scott Specialty Gases. Human subjects aged 21 to 45 were instructed to place the KNB over their nose and mouth and to breathe normally before and after mild exercise (n=24) and relaxation (n=20). Mean exhaled NO measurements were compared before and after the protocols using paired t-tests. Regardless of the test, all subjects exhibited NO in their exhaled breath. Exhaled NO decreased significantly after exercise compared to the first reading just prior to the exercise protocol. The mean +/-SE of exhaled NO was 22.8+/-4 before and 13.0+/-2 ppb after exercise (n=24, P=0.003). In the resting experiment, exhaled NO was demonstrated to increase significantly after 10 min compared to the reading taken right after the individuals sat down. The present study demonstrates NO in exhaled human breath can vary, reflecting the activity state of the individual. Additionally, the study demonstrates that NO in exhaled human breath can be measured rapidly, with high sensitivity, and in real time via the KNB, representing an affordable means to achieve this determination.
Frequency of rhinitis and orofacial disorders in patients with dental malocclusion
Imbaud, Tamara Christine de Souza; Mallozi, Márcia Carvalho; Domingos, Vanda Beatriz Teixeira Coelho; Solé, Dirceu
2016-01-01
Abstract Objective: To describe the frequency and etiology of rhinitis, oral breathing, types of malocclusion and orofacial disorders in patients treated for dental malocclusion. Methods: Patients with poor dental occlusion (n=89, 8-15 years) undergoing orthodontic treatment at the Postgraduate Orthodontics Center (São Paulo, Brazil) participated in the study. Rhinitis and oral breathing were diagnosed by anamnesis, clinical assessment and allergic etiology of rhinitis through immediate hypersensitivity skin prick test with airborne allergens. The association between types of breathing (oral or nasal), rhinitis and types of dental malocclusion, bruxism and cephalometric alterations (increased Y axis of facial growth) compared to standard cephalometric tracing (Escola de Odontologia da Universidade de São Paulo) were assessed. Results: The frequency of rhinitis in patients with dental malocclusion was 76.4% (68), and, of these, 81.7% were allergic (49/60 positive skin prick test), whereas the frequency of oral breathing was 62.9%. There was a significant association between an increased Y axis of facial growth and oral breathing (p<0.001), as well as between oral breathing and rhinitis (p=0.009). There was no association between rhinitis and bruxism. Conclusions: The frequency of rhinitis in children with dental malocclusion is higher than that in the general population, which is approximately 30%. Patients with oral breathing have a tendency to a dolichofacial growth pattern (increased Y axis of facial growth). In patients with rhinitis, regardless of the presence of oral breathing, the dolichofacial growth tendency was not observed. PMID:26631324
Afternoon serum-melatonin in sleep disordered breathing.
Ulfberg, J; Micic, S; Strøm, J
1998-08-01
To study afternoon serum-melatonin values in patients with sleep disordered breathing. Melatonin has a strong circadian rhythm with high values during the night-time and low values in the afternoon. Sleep disordered breathing may change the circadian rhythm of melatonin which may have diagnostic implications. The Sleep Laboratory, The Department of Internal Medicine, Avesta Hospital, Sweden, and the Department of Anaesthesiology, Glostrup University Hospital, Copenhagen, Denmark. We examined 60 consecutive patients admitted for sleep disordered breathing and 10 healthy non snoring controls. The patients underwent a sleep apnoea screening test having a specificity of 100% for the obstructive sleep apnoea syndrome (OSAS) using a combination of static charge sensitive bed and oximetry. Obstructive sleep apnoea syndrome was found in 49 patients, eight patients had borderline sleep disordered breathing (BSDB) and three patients were excluded due to interfering disease. Patients and controls had an afternoon determination of serum-melatonin. The Epworth Sleepiness Scale was used to score day-time sleepiness. In comparison with normal controls patients suffering from OSAS had significantly higher serum-melatonin levels in the afternoon. However, as a diagnostic test for OSAS in patients with sleep disordered breathing serum-melatonin showed a low sensitivity but a high specificity. The results indicate that breathing disorders during sleep in general affect pineal function. Sleep disordered breathing seems to disturb pineal function. Determination of afternoon serum-melatonin alone or together with a scoring of daytime sleepiness does not identify OSAS-patients in a heterogeneous population of patients complaining of heavy snoring and excessive daytime sleepiness.
Noise Reduction in Breath Sound Files Using Wavelet Transform Based Filter
NASA Astrophysics Data System (ADS)
Syahputra, M. F.; Situmeang, S. I. G.; Rahmat, R. F.; Budiarto, R.
2017-04-01
The development of science and technology in the field of healthcare increasingly provides convenience in diagnosing respiratory system problem. Recording the breath sounds is one example of these developments. Breath sounds are recorded using a digital stethoscope, and then stored in a file with sound format. This breath sounds will be analyzed by health practitioners to diagnose the symptoms of disease or illness. However, the breath sounds is not free from interference signals. Therefore, noise filter or signal interference reduction system is required so that breath sounds component which contains information signal can be clarified. In this study, we designed a filter called a wavelet transform based filter. The filter that is designed in this study is using Daubechies wavelet with four wavelet transform coefficients. Based on the testing of the ten types of breath sounds data, the data is obtained in the largest SNRdB bronchial for 74.3685 decibels.
Edwards, A M; Challis, N V; Chapman, J H; Claxton, D B; Fysh, M L
1999-01-01
The aim of the study was to examine whether a measure of oxygen uptake (VO2) kinetics could differentiate between 12 elite male endurance (3000-10,000 m) runners and 12 elite male sprint (100-400 m) runners using a pseudo random binary sequence (PRBS) exercise protocol. All exercise tests were performed on an electrically braked cycle ergometer at a constant pedal frequency of 1 Hz. The PRBS exercise intensities alternated between 25 W and 85 W for three consecutive PRBS cycles of 300 s. VO2 was measured breath-by-breath and results were analysed by Fourier techniques in the frequency domain. Blood lactate concentrations taken pre and post testing were below 2 mM. Significantly greater amplitude components were observed in the endurance runners than sprinters at frequencies 6.7 mHz (6.71 +/- 1.09 and 5.47 +/- 0.95 ml x min(-1) x W(-1), respectively) P<0.05 and 10 mHz (4.97 +/- 0.98 and 3.56 +/- 0.69 ml x min(-1) x W(-1) respectively) P<0.01. Phase shift components were significantly shorter in the endurance runners compared to the sprinters at frequency 3.3 mHz (-35.45 +/- 4.31 and -41.26 +/- 5.82 degrees respectively) P<0.05. The results of this study show that VO2 kinetics are differentially faster in elite endurance runners than in elite sprinters. This supports the development of the PRBS technique as a test of sports performance.
Wang, Min; Wang, Zhiling; Gou, Lingyan; Zhang, Yuhui; Yang, Xiaoguang; Sha, Lei; Li, Min
2013-03-01
To assess the validity and reliability of the infrared spectrometry for measuring the delta over baseline for breath 13C. Twenty-four healthy adults were selected, including twelve males and twelve females. 13C-Leucine was used as tracer in stable isotope metabolic experiments. One baseline breath was collected before the tracer protocol began. Other breath samples were collected at 60, 120, 180, 195, 210, 225, 240, 255, 270 and 300 min post-tracer challenge. The delta over baseline for breath 13C was measured by the infrared spectrometry and Heliview 13C breath analyzer. No significant differences were found between the infrared spectrometry and Heliview 13C breath analyzer in measuring the delta over baseline for breath 13C. The F value and p value of two-way ANOVA were 0.29 and 0.5874 respectively. The t and p value of consistency test were 0.48 and 0.6346 respectively. The 13C infrared spectrometry can reliably measure the delta over baseline for breath 13C.
Breathing and sense of self: visuo-respiratory conflicts alter body self-consciousness.
Adler, Dan; Herbelin, Bruno; Similowski, Thomas; Blanke, Olaf
2014-11-01
Bodily self-consciousness depends on the processing of interoceptive and exteroceptive signals. It can be disrupted by inducing signal conflicts. Breathing, at the crossroad between interoception and exteroception, should contribute to bodily self-consciousness. We induced visuo-respiratory conflicts in 17 subjects presented with a virtual body or a parallelepidedal object flashing synchronously or asynchronously with their breathing. A questionnaire detected illusory changes in bodily self-consciousness and breathing agency (the feeling of sensing one's breathing command). Changes in self-location were tested by measuring reaction time during mental ball drop (MBD). Synchronous illumination changed the perceived location of breathing (body: p=0.008 vs. asynchronous; object: p=0.013). It resulted in a significant change in breathing agency, but no changes in self-identification. This was corroborated by prolonged MBD reaction time (body: +0.045s, 95%CI [0.013; 0.08], p=0.007). We conclude that breathing modulates bodily self-consciousness. We also conclude that one can induce the irruption of unattended breathing into consciousness without modifying respiratory mechanics or gas exchange. Copyright © 2014 Elsevier B.V. All rights reserved.
32 CFR 634.37 - Voluntary breath and bodily fluid testing based on implied consent.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.37 Voluntary breath and bodily fluid testing based on implied consent... the person was driving under the influence of alcohol or drugs. (3) A request was made to the person...
32 CFR 634.37 - Voluntary breath and bodily fluid testing based on implied consent.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.37 Voluntary breath and bodily fluid testing based on implied consent... the person was driving under the influence of alcohol or drugs. (3) A request was made to the person...
Erickson, Jennifer; Wang, Qi; Slavin, Joanne
2017-06-01
Diets low in fermentable oligosaccharides, disaccharides, monosaccharides, and polyols (FODMAPS) are used to manage symptoms in individuals with irritable bowel syndrome. Although effective at reducing symptoms, the diet can be complex and restrictive. In addition, there are still large gaps in the literature and many foods with unclear effects in the gastrointestinal (GI) tract, like fruit juice. Although many fruits are allowable on a low-FODMAP diet, consumption of all fruit juice is generally cautioned due to the large fructose load contained in juice, regardless of the glucose concentration. Very little research exists regarding the importance of limiting fructose load during a low-FODMAP diet; therefore, individuals following a low-FODMAP diet may be unnecessarily restricting their diets. To determine whether there is a difference in GI tolerance between juice from a high-FODMAP fruit (apple juice) and juice from a low-FODMAP fruit (white grape juice) in healthy human subjects. The goal is to provide insight into the role of juice in a low-FODMAP diet. A double-blind, randomized, controlled crossover study was conducted with 40 healthy adults. Fasted subjects consumed 12 oz of either apple juice or white grape juice. Breath hydrogen measures were taken at baseline, 1, 2, and 3 hours. Subjective GI tolerance surveys were completed at the same time intervals and at 12 and 24 hours. Breath hydrogen and GI symptoms were assessed with area under the curve analysis. Significance was determined with a two-sided t test with a P value <0.05. Consumption of apple juice resulted in a greater mean breath hydrogen area under the curve at 23.3 ppm/hour (95% CI 13.0 to 33.6) compared with white grape juice at 5.8 ppm/hour (95% CI -4.6 to 16.1) (P<0.001). No differences in reported GI symptoms were seen between treatments. Both juices were well tolerated and neither produced any severe symptoms in healthy adults. White grape juice consumption resulted in only a small rise in breath hydrogen, which may suggest excluding foods only because of the high fructose load could be unnecessarily restrictive. The results of this study suggest that the fructose-to-glucose ratio is likely more important than the total fructose load of the food when considering the acceptability of a food on a low-FODMAP diet. More research is needed in individuals with irritable bowel syndrome to determine whether white grape juice and other juices from low-FODMAP fruits could be additional beverage options for individuals following a low-FODMAP diet. Copyright © 2017 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
Holtyn, August F; Jarvis, Brantley P; Subramaniam, Shrinidhi; Wong, Conrad J; Fingerhood, Michael; Bigelow, George E; Silverman, Kenneth
2017-09-01
Excessive alcohol use among the homeless may contribute to their high rates of emergency department use. Survey-based studies have provided some information on the relation between alcohol and emergency department use among the homeless. This study used an intensive schedule of random breath collections and self-report assessments to examine the relation between emergency department utilization and alcohol use in homeless alcohol-dependent adults. Data were from homeless alcohol-dependent adults (N=116) who were participating in a therapeutic workplace that provided job-skills training every weekday for 26 weeks. Breath-sample collections and assessments of self-reported alcohol use were scheduled each week, an average of twice per week per participant, at random times between 9:00 A.M. and 5:00 P.M. Participants received $35 for each breath sample collected. Self-reports of emergency department use were assessed throughout the study. Thirty-four percent of participants reported attending an emergency department and reported an average of 2.2 emergency department visits (range 1-10 visits). Alcohol intoxication was the most common reason for emergency department use. Participants who used the emergency department had significantly more alcohol-positive breath samples and more self-reported heavy alcohol use than participants who did not use the emergency department. This study provided a rare intensive assessment of alcohol and emergency department use in homeless alcohol-dependent adults over an extended period. Emergency department use was high and was significantly related to indices of alcohol use. Copyright © 2017 Elsevier B.V. All rights reserved.
Okamura, Takayuki; Yamamoto, Takatsugu; Kimura, Satoshi; Miki, Atsushi; Abe, Koichiro; Kita, Hiroto
2017-11-01
Lubiprostone is effective for patients with chronic constipation. This agent sometimes causes upper gastrointestinal symptoms, such as nausea, which is one of the chief reasons for discontinuation. However, the etiology of and strategy against bothersome gastrointestinal symptoms of lubiprostone remain unclear. The goal of this study was to investigate the influence of lubiprostone on the gastric-emptying profile of healthy adults. The effect of domperidone on gastric emptying and gastrointestinal symptoms after lubiprostone administration were also assessed. 80 healthy male participants underwent 13C acetate breath testing to evaluate gastric emptying. The test meal comprised 200 kcal of a standard liquid nutrient. Each participant underwent 3 random breath tests with: 1) no premedication; 2) 24 µg of lubiprostone 30 minutes prior to the study; and 3) 24 µg of lubiprostone plus 10 mg of domperidone 30 minutes prior to the study. Gastrointestinal symptoms (heartburn, regurgitation, epigastric pain, fullness, distress feeling) during testing were evaluated using a 7-point scoring system. Gastric emptying was significantly delayed by the administration of lubiprostone. Among all 8 subjects, 4 reported heartburn after taking lubiprostone, whereas this symptom was not found when subjects received concomitant domperidone. However, gastric emptying showed little change between lubiprostone alone and lubiprostone plus domperidone. Lubiprostone delayed gastric emptying of liquid in healthy adults, which could be associated with the gastrointestinal symptoms caused by the agent. Domperidone seemed effective against such gastrointestinal symptoms after administration of lubiprostone. This effect seemed unrelated to gastric motility. .
2012-01-01
Background After completion of curative breast cancer treatment, patients go through a transition from patient to survivor. During this re-entry phase, patients are faced with a broad range of re-entry topics, concerning physical and emotional recovery, returning to work and fear of recurrence. Standard and easy-accessible care to facilitate this transition is lacking. In order to facilitate adjustment for all breast cancer patients after primary treatment, the BREATH intervention is aimed at 1) decreasing psychological distress, and 2) increasing empowerment, defined as patients’ intra- and interpersonal strengths. Methods/design The non-guided Internet-based self-management intervention is based on cognitive behavioural therapy techniques and covers four phases of recovery after breast cancer (Looking back; Emotional processing; Strengthening; Looking ahead). Each phase of the fully automated intervention has a fixed structure that targets consecutively psychoeducation, problems in everyday life, social environment, and empowerment. Working ingredients include Information (25 scripts), Assignment (48 tasks), Assessment (10 tests) and Video (39 clips extracted from recorded interviews). A non-blinded, multicentre randomised controlled, parallel-group, superiority trial will be conducted to evaluate the effectiveness of the BREATH intervention. In six hospitals in the Netherlands, a consecutive sample of 170 will be recruited of women who completed primary curative treatment for breast cancer within 4 months. Participants will be randomly allocated to receive either usual care or usual care plus access to the online BREATH intervention (1:1). Changes in self-report questionnaires from baseline to 4 (post-intervention), 6 and 10 months will be measured. Discussion The BREATH intervention provides a psychological self-management approach to the disease management of breast cancer survivors. Innovative is the use of patients’ own strengths as an explicit intervention target, which is hypothesized to serve as a buffer to prevent psychological distress in long-term survivorship. In case of proven (cost) effectiveness, the BREATH intervention can serve as a low-cost and easy-accessible intervention to facilitate emotional, physical and social recovery of all breast cancer survivors. Trial registration This study is registered at the Netherlands Trial Register (NTR2935) PMID:22958799
NASA Astrophysics Data System (ADS)
Ageev, V. G.; Nikiforova, O. Yu.
2016-11-01
We determined the carbon dioxide concentrations in exhaled breath from healthy donors and patients with various diseases from the absorption spectra of test samples, recorded on a laser optoacoustic gas analyzer based on a CO2 laser. We observed that the carbon dioxide concentrations in exhaled breath from healthy donors is higher than in patients with various diseases.
Test plan 241-C-103 natural breathing characteristics evaluation using the ultra sensitive flowmeter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hertelendy, N.A.
1995-02-13
To facilitate the reduction of worker exposure to hazardous fumes and vapors, it is imperative to characterize and measure flows out of waste tanks that breathe due to atmospheric pressure changes. These measurements will lead to a better understanding of how these tanks breathe and thus will aid in better worker exposure control at lower cost.
A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals
Ma, Yong-Jian; Zhang, Hou-De; Ji, Yong-Qiang; Zhu, Guo-Liang; Huang, Jia-Liang; Du, Li-Tao; Cao, Ping; Zang, De-Yue; Du, Ji-Hui; Li, Rong; Wang, Lei
2016-01-01
This study was to develop a CO breath test for RBC lifespan estimation of small animals. The ribavirin induced hemolysis rabbit models were placed individually in a closed rebreath cage and air samples were collected for measurement of CO concentration. RBC lifespan was calculated from accumulated CO, blood volume, and hemoglobin concentration data. RBC lifespan was determined in the same animals with the standard biotin-labeling method. RBC lifespan data obtained by the CO breath test method for control (CON, 49.0 ± 5.9 d) rabbits, rabbits given 10 mg/kg·d−1 of ribavirin (RIB10, 31.0 ± 4.0 d), and rabbits given 20 mg/kg·d−1 of ribavirin (RIB20, 25.0 ± 2.9 d) were statistically similar (all p > 0.05) to and linearly correlated (r = 0.96, p < 0.01) with the RBC lifespan data obtained for the same rabbits by the standard biotin-labeling method (CON, 51.0 ± 2.7 d; RIB10, 33.0 ± 1.3 d; and RIB20, 27.0 ± 0.8 d). The CO breath test method takes less than 3 h to complete, whereas the standard method requires at least several weeks. In conclusion, the CO breath test method provides a simple and rapid means of estimating RBC lifespan and is feasible for use with small animal models. PMID:27294128
Ibba, Ivan; Gilli, Agnese; Boi, Maria Francesca; Usai, Paolo
2014-01-01
To establish whether supplementation with a standard oral dose of Beta-Galactosidase affects hydrogen breath excretion in patients presenting with lactose malabsorption. Ninety-six consecutive patients positive to H2 Lactose Breath Test were enrolled. Mean peak H2 levels, the time to reach the peak H2, the time to reach the cut-off value of 20 ppm, the cumulative breath H2 excretion, the areas under the curve, and a Visual Analogical 10-point Scale for symptoms were calculated. Genotyping of the C/T-13910 variant was carried out. Following the oral administration of Beta-Galactosidase, in 21.88% of the cases, H2 Lactose Breath Test became negative (Group A), while mean peak H2 levels (74.95 ppm versus 7.85), P < 0.0000, in 17.71% (Group B) were still positive, with the H2 level 20 ppm above the baseline, but the peak H2 levels were significantly lower than those observed at the baseline test (186.7 ppm versus 66.64), P < 0.0000, while in 60.41% (Group C) they were still positive with the peak H2 levels similar to those observed at the baseline test (94.43 versus 81.60 ppm). All 96 individuals tested presented the C/C-13910 genotype nonpersistence. The response to oral administration of Beta-Galactosidase in patients with symptoms of lactose malabsorption presents a significant variability.
Update on diagnostic value of breath test in gastrointestinal and liver diseases
Siddiqui, Imran; Ahmed, Sibtain; Abid, Shahab
2016-01-01
In the field of gastroenterology, breath tests (BTs) are used intermittently as diagnostic tools that allow indirect, non-invasive and relatively less cumbersome evaluation of several disorders by simply quantifying the appearance in exhaled breath of a metabolite of a specific substrate administered. The aim of this review is to have an insight into the principles, methods of analysis and performance parameters of various hydrogen, methane and carbon BTs which are available for diagnosing gastrointestinal disorders such as Helicobacter pylori infection, small intestinal bacterial overgrowth, and carbohydrate malabsorption. Evaluation of gastric emptying is routinely performed by scintigraphy which is however, difficult to perform and not suitable for children and pregnant women, this review has abridged the 13C-octanoic acid test in comparison to scintigraphy and has emphasized on its working protocol and challenges. A new development such as electronic nose test is also highlighted. Moreover we have also explored the limitations and constraints restraining the wide use of these BT. We conclude that breath testing has an enormous potential to be used as a diagnostic modality. In addition it offers distinct advantages over the traditional invasive methods commonly employed. PMID:27574563
Ribeiro, Rhayssa; Brandão, Daniella; Noronha, Jéssica; Lima, Cibelle; Fregonezi, Guilherme; Resqueti, Vanessa; Dornelas de Andrade, Arméle
2018-05-01
Patients with Parkinson's disease often exhibit respiratory disorders and there are no Respiratory Therapy protocols which are suggested as interventions in Parkinson's patients. The aim of this study is to evaluate the effects of Breathing-Stacking (BS) and incentive spirometer (IS) techniques in volume variations of the chest wall in patients with Parkinson's Disease (PD). 14 patients with mild-moderate PD were included in this randomized cross-over study. Volume variations of the chest wall were assessed before, immediately after, then 15 and 30 min after BS and IS performance by optoelectronic plethysmography. Tidal volume (VT) and minute ventilation (MV) significantly increased after BS and IS techniques (p < 0.05). There was greater involvement of pulmonary and abdominal compartments after IS. The results suggest that these re-expansion techniques can be performed to immediately improve volume. Copyright © 2018 Elsevier B.V. All rights reserved.
Evaluation of 13CO2 breath tests for the detection of fructose malabsorption.
Hoekstra, J H; van den Aker, J H; Kneepkens, C M; Stellaard, F; Geypens, B; Ghoos, Y F
1996-03-01
Breath hydrogen (H2) studies have made clear that small intestinal absorption of fructose is limited, especially in toddlers. Malabsorption of fructose may be a cause of recurrent abdominal pain and chronic nonspecific diarrhea (toddler's diarrhea). Fructose absorption is facilitated by equimolar doses of glucose and, as we have found, amino acids (especially L-alanine); the mechanism underlying this effect remains unclear. To study fructose absorption in a more direct way, we combined breath H2 studies with breath 13CO2 studies. Gastric emptying was studied by using L-glycine-1-13C in 4 children from 12.1 to 16.0 years of age. After 25 gm of fructose and 27.5 gm of glucose, when given together, gastric emptying was significantly (p<0.05) slower than with either sugar alone. In a second series of experiments, 5 children from 12.0 to 15.9 years of age were tested with 25 gm of fructose, alone and with equimolar doses of glucose and L-alanine, and 4 younger children from 3.1 to 6.1 years of age were tested with 2 gm/kg (max 37.5 gm) fructose, alone or with an equimolar dose of L-alanine. All fructose solutions were enriched with 15 mg of D-fructose-13C-6. In all 9 children, fructose was malabsorbed as judged by breath H2 increases > or = 20 ppm, and the addition of glucose or L-alanine resulted in significantly lower breath H2 increases (p < or = 0.005 for glucose, p < or = 0.001 for alanine). In contrast, the addition of alanine or glucose did not change the pattern of breath 13CO2 excretion in the 5 older children, whereas in the 4 younger children (with relatively higher doses), L-alanine addition resulted in significantly lower increases in breath 13CO2. In the latter group, for each time point, breath H2 and 13CO2 concentrations after fructose were compared with those after fructose plus L-alanine; in 20 out of 24 points, both H2 and 13CO2 were higher after fructose. These results suggest that 13CO2 not only originated from the oxidation of absorbed substrate but also, at least in part, from colonic bacterial metabolism. For the detection of [correction of or] fructose malabsorption--as opposed to, for instance, lactose--the 13CO2 breath test seems to be of limited value.
21 CFR 862.3080 - Breath nitric oxide test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... fractional nitric oxide concentration in expired breath aids in evaluating an asthma patient's response to anti-inflammatory therapy, as an adjunct to established clinical and laboratory assessments of asthma...
Lactose Intolerance (For Parents)
... Doctors usually diagnose lactose intolerance through a simple hydrogen breath test. A person blows into a tube ... there is a higher than average level of hydrogen and methane in the breath. That's because undigested ...
Beyer, Peter L; Caviar, Elena M; McCallum, Richard W
2005-10-01
Fructose intake has increased considerably in the United States, primarily as a result of increased consumption of high-fructose corn syrup, fruits and juices, and crystalline fructose. The purpose was to determine how often fructose, in amounts commonly consumed, would result in malabsorption and/or symptoms in healthy persons. Fructose absorption was measured using 3-hour breath hydrogen tests and symptom scores were used to rate subjective responses for gas, borborygmus, abdominal pain, and loose stools. The study included 15 normal, free-living volunteers from a medical center community and was performed in a gastrointestinal specialty clinic. Subjects consumed 25- and 50-g doses of crystalline fructose with water after an overnight fast on separate test days. Mean peak breath hydrogen, time of peak, area under the curve (AUC) for breath hydrogen and gastrointestinal symptoms were measured during a 3-hour period after subjects consumed both 25- and 50-g doses of fructose. Differences in mean breath hydrogen, AUC, and symptom scores between doses were analyzed using paired t tests. Correlations among peak breath hydrogen, AUC, and symptoms were also evaluated. More than half of the 15 adults tested showed evidence of fructose malabsorption after 25 g fructose and greater than two thirds showed malabsorption after 50 g fructose. AUC, representing overall breath hydrogen response, was significantly greater after the 50-g dose. Overall symptom scores were significantly greater than baseline after each dose, but scores were only marginally greater after 50 g than 25 g. Peak hydrogen levels and AUC were highly correlated, but neither was significantly related to symptoms. Fructose, in amounts commonly consumed, may result in mild gastrointestinal distress in normal people. Additional study is warranted to evaluate the response to fructose-glucose mixtures (as in high-fructose corn syrup) and fructose taken with food in both normal people and those with gastrointestinal dysfunction. Because breath hydrogen peaks occurred at 90 to 114 minutes and were highly correlated with 180-minute breath hydrogen AUC, the use of peak hydrogen measures may be considered to shorten the duration of the exam.
Photoacoustic sensor for medical diagnostics
NASA Astrophysics Data System (ADS)
Wolff, Marcus; Groninga, Hinrich G.; Harde, Hermann
2004-03-01
The development of new optical sensor technologies has a major impact on the progress of diagnostic methods. Of the permanently increasing number of non-invasive breath tests, the 13C-Urea Breath Test (UBT) for the detection of Helicobacter pylori is the most prominent. However, many recent developments, like the detection of cancer by breath test, go beyond gastroenterological applications. We present a new detection scheme for breath analysis that employs an especially compact and simple set-up. Photoacoustic Spectroscopy (PAS) represents an offset-free technique that allows for short absorption paths and small sample cells. Using a single-frequency diode laser and taking advantage of acoustical resonances of the sample cell, we performed extremely sensitive and selective measurements. The smart data processing method contributes to the extraordinary sensitivity and selectivity as well. Also, the reasonable acquisition cost and low operational cost make this detection scheme attractive for many biomedical applications. The experimental set-up and data processing method, together with exemplary isotope-selective measurements on carbon dioxide, are presented.
Psychological predictors of the antihypertensive effects of music-guided slow breathing.
Modesti, Pietro Amedeo; Ferrari, Antonella; Bazzini, Cristina; Costanzo, Giusi; Simonetti, Ignazio; Taddei, Stefano; Biggeri, Annibale; Parati, Gianfranco; Gensini, Gian Franco; Sirigatti, Saulo
2010-05-01
The possibility that daily sessions of music-guided slow breathing may reduce 24-h ambulatory blood pressure (ABP), and predictors of efficacy were explored in a randomized, placebo-controlled trial with parallel design. Age-matched and sex-matched hypertensive patients were randomized to music-guided slow breathing exercises (4-6 breaths/min; 1: 2 ratio of inspiration: expiration duration) (Intervention; n = 29) or to control groups who were thought to relax while either listening to slow music (Control-M; n = 26) or reading a book (Control-R; n = 31). At baseline and at follow-up visits (1 week and 1, 3 and 6 months), ABP monitoring was performed. At mixed model analysis, intervention was associated with a significant reduction of 24-h (P = 0.001) and night-time (0100-0600 h) (P < 0.0001) systolic ABP. The average reduction of systolic 24-h ABP at 6 months was 4.6 mmHg [confidence limits at 95% 1.93-7.35] and 4.1 mmHg (95% confidence limits 1.59-6.67) vs. Control-M and Control-R groups, respectively, (P < 0.001 for both). Antihypertensive treatment was selected as negative predictor of BP reduction at multivariate stepwise analysis. When antihypertensive treatment was inserted as covariate in a generalized linear model, psychological subscales assessed at baseline by the Mental Health Inventory questionnaire were found to affect systolic blood pressure reduction at 6-month follow-up (general positive affect P < 0.001; emotional ties, P < 0.001; loss of behavioral control, P = 0.035). In particular, a level of general positive affect higher than the 75th percentiles was found to be significantly associated with low treatment efficacy (odds ratio 0.09; 95% confidence limits 0.01-0.93). Daily sessions of voluntary music-guided slow breathing significantly reduce 24-h systolic ABP, and psychological predictors of efficacy can be identified.
Dominelli, Paolo B; Molgat-Seon, Yannick; Griesdale, Donald E G; Peters, Carli M; Blouin, Jean-Sébastien; Sekhon, Mypinder; Dominelli, Giulio S; Henderson, William R; Foster, Glen E; Romer, Lee M; Koehle, Michael S; Sheel, A William
2017-08-01
High work of breathing and exercise-induced arterial hypoxaemia (EIAH) can decrease O 2 delivery and exacerbate exercise-induced quadriceps fatigue in healthy men. Women have a higher work of breathing during exercise, dedicate a greater fraction of whole-body V̇O2 towards their respiratory muscles and develop EIAH. Despite a greater reduction in men's work of breathing, the attenuation of quadriceps fatigue was similar between the sexes. The degree of EIAH was similar between sexes, and regardless of sex, those who developed the greatest hypoxaemia during exercise demonstrated the most attenuation of quadriceps fatigue. Based on our previous finding that women have a greater relative oxygen cost of breathing, women appear to be especially susceptible to work of breathing-related changes in quadriceps muscle fatigue. Reducing the work of breathing or eliminating exercise-induced arterial hypoxaemia (EIAH) during exercise decreases the severity of quadriceps fatigue in men. Women have a greater work of breathing during exercise, dedicate a greater fraction of whole-body V̇O2 towards their respiratory muscles, and demonstrate EIAH, suggesting women may be especially susceptible to quadriceps fatigue. Healthy subjects (8 male, 8 female) completed three constant load exercise tests over 4 days. During the first (control) test, subjects exercised at ∼85% of maximum while arterial blood gases and work of breathing were assessed. Subsequent constant load exercise tests were iso-time and iso-work rate, but with EIAH prevented by inspiring hyperoxic gas or work of breathing reduced via a proportional assist ventilator (PAV). Quadriceps fatigue was assessed by measuring force in response to femoral nerve stimulation. For both sexes, quadriceps force was equally reduced after the control trial (-27 ± 2% baseline) and was attenuated with hyperoxia and PAV (-18 ± 1 and -17 ± 2% baseline, P < 0.01, respectively), with no sex difference. EIAH was similar between the sexes, and regardless of sex, subjects with the lowest oxyhaemoglobin saturation during the control test had the greatest quadriceps fatigue attenuation with hyperoxia (r 2 = 0.79, P < 0.0001). For the PAV trial, despite reducing the work of breathing to a greater degree in men (men: 60 ± 5, women: 75 ± 6% control, P < 0.05), the attenuation of quadriceps fatigue was similar between the sexes (36 ± 4 vs. 37 ± 7%). Owing to a greater relative V̇O2 of the respiratory muscles in women, less of a change in work of breathing is needed to reduce quadriceps fatigue. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.
A probability-based multi-cycle sorting method for 4D-MRI: A simulation study.
Liang, Xiao; Yin, Fang-Fang; Liu, Yilin; Cai, Jing
2016-12-01
To develop a novel probability-based sorting method capable of generating multiple breathing cycles of 4D-MRI images and to evaluate performance of this new method by comparing with conventional phase-based methods in terms of image quality and tumor motion measurement. Based on previous findings that breathing motion probability density function (PDF) of a single breathing cycle is dramatically different from true stabilized PDF that resulted from many breathing cycles, it is expected that a probability-based sorting method capable of generating multiple breathing cycles of 4D images may capture breathing variation information missing from conventional single-cycle sorting methods. The overall idea is to identify a few main breathing cycles (and their corresponding weightings) that can best represent the main breathing patterns of the patient and then reconstruct a set of 4D images for each of the identified main breathing cycles. This method is implemented in three steps: (1) The breathing signal is decomposed into individual breathing cycles, characterized by amplitude, and period; (2) individual breathing cycles are grouped based on amplitude and period to determine the main breathing cycles. If a group contains more than 10% of all breathing cycles in a breathing signal, it is determined as a main breathing pattern group and is represented by the average of individual breathing cycles in the group; (3) for each main breathing cycle, a set of 4D images is reconstructed using a result-driven sorting method adapted from our previous study. The probability-based sorting method was first tested on 26 patients' breathing signals to evaluate its feasibility of improving target motion PDF. The new method was subsequently tested for a sequential image acquisition scheme on the 4D digital extended cardiac torso (XCAT) phantom. Performance of the probability-based and conventional sorting methods was evaluated in terms of target volume precision and accuracy as measured by the 4D images, and also the accuracy of average intensity projection (AIP) of 4D images. Probability-based sorting showed improved similarity of breathing motion PDF from 4D images to reference PDF compared to single cycle sorting, indicated by the significant increase in Dice similarity coefficient (DSC) (probability-based sorting, DSC = 0.89 ± 0.03, and single cycle sorting, DSC = 0.83 ± 0.05, p-value <0.001). Based on the simulation study on XCAT, the probability-based method outperforms the conventional phase-based methods in qualitative evaluation on motion artifacts and quantitative evaluation on tumor volume precision and accuracy and accuracy of AIP of the 4D images. In this paper the authors demonstrated the feasibility of a novel probability-based multicycle 4D image sorting method. The authors' preliminary results showed that the new method can improve the accuracy of tumor motion PDF and the AIP of 4D images, presenting potential advantages over the conventional phase-based sorting method for radiation therapy motion management.
Sandberg, Jonna C.; Björck, Inger M. E.; Nilsson, Anne C.
2016-01-01
Background Whole grain has shown potential to prevent obesity, cardiovascular disease and type 2 diabetes. Possible mechanism could be related to colonic fermentation of specific indigestible carbohydrates, i.e. dietary fiber (DF). The aim of this study was to investigate effects on cardiometabolic risk factors and appetite regulation the next day when ingesting rye kernel bread rich in DF as an evening meal. Method Whole grain rye kernel test bread (RKB) or a white wheat flour based bread (reference product, WWB) was provided as late evening meals to healthy young adults in a randomized cross-over design. The test products RKB and WWB were provided in two priming settings: as a single evening meal or as three consecutive evening meals prior to the experimental days. Test variables were measured in the morning, 10.5–13.5 hours after ingestion of RKB or WWB. The postprandial phase was analyzed for measures of glucose metabolism, inflammatory markers, appetite regulating hormones and short chain fatty acids (SCFA) in blood, hydrogen excretion in breath and subjective appetite ratings. Results With the exception of serum CRP, no significant differences in test variables were observed depending on length of priming (P>0.05). The RKB evening meal increased plasma concentrations of PYY (0–120 min, P<0.001), GLP-1 (0–90 min, P<0.05) and fasting SCFA (acetate and butyrate, P<0.05, propionate, P = 0.05), compared to WWB. Moreover, RKB decreased blood glucose (0–120 min, P = 0.001), serum insulin response (0–120 min, P<0.05) and fasting FFA concentrations (P<0.05). Additionally, RKB improved subjective appetite ratings during the whole experimental period (P<0.05), and increased breath hydrogen excretion (P<0.001), indicating increased colonic fermentation activity. Conclusion The results indicate that RKB evening meal has an anti-diabetic potential and that the increased release of satiety hormones and improvements of appetite sensation could be beneficial in preventing obesity. These effects could possibly be mediated through colonic fermentation. Trial Registration ClinicalTrials.gov NCT02093481 PMID:26990559
Sandberg, Jonna C; Björck, Inger M E; Nilsson, Anne C
2016-01-01
Whole grain has shown potential to prevent obesity, cardiovascular disease and type 2 diabetes. Possible mechanism could be related to colonic fermentation of specific indigestible carbohydrates, i.e. dietary fiber (DF). The aim of this study was to investigate effects on cardiometabolic risk factors and appetite regulation the next day when ingesting rye kernel bread rich in DF as an evening meal. Whole grain rye kernel test bread (RKB) or a white wheat flour based bread (reference product, WWB) was provided as late evening meals to healthy young adults in a randomized cross-over design. The test products RKB and WWB were provided in two priming settings: as a single evening meal or as three consecutive evening meals prior to the experimental days. Test variables were measured in the morning, 10.5-13.5 hours after ingestion of RKB or WWB. The postprandial phase was analyzed for measures of glucose metabolism, inflammatory markers, appetite regulating hormones and short chain fatty acids (SCFA) in blood, hydrogen excretion in breath and subjective appetite ratings. With the exception of serum CRP, no significant differences in test variables were observed depending on length of priming (P>0.05). The RKB evening meal increased plasma concentrations of PYY (0-120 min, P<0.001), GLP-1 (0-90 min, P<0.05) and fasting SCFA (acetate and butyrate, P<0.05, propionate, P = 0.05), compared to WWB. Moreover, RKB decreased blood glucose (0-120 min, P = 0.001), serum insulin response (0-120 min, P<0.05) and fasting FFA concentrations (P<0.05). Additionally, RKB improved subjective appetite ratings during the whole experimental period (P<0.05), and increased breath hydrogen excretion (P<0.001), indicating increased colonic fermentation activity. The results indicate that RKB evening meal has an anti-diabetic potential and that the increased release of satiety hormones and improvements of appetite sensation could be beneficial in preventing obesity. These effects could possibly be mediated through colonic fermentation. ClinicalTrials.gov NCT02093481.
Breathing metabolic simulator.
NASA Technical Reports Server (NTRS)
Bartlett, R. G., Jr.; Hendricks, C. M.; Morison, W. B.
1971-01-01
Description of a device for simulation of the human breathing and metabolic parameters required for the evaluation of respiratory diagnostic, monitoring, support and resuscitation equipment. The remotely controlled device allows wide variations in breathing rate and depth, breath velocity contour, oxygen uptake and carbon dioxide release to simulate conditions from sleep to hard work, with respiration exchange ratios ranging from hypoventilation to hyperventilation. It also reduces the cost of prolonged testing when simulation chambers with human subjects require three shifts of crews and standby physicians. Several block diagrams of the device and subsystems are given.
Diagnosis of acute respiratory distress syndrome by exhaled breath analysis
2018-01-01
The acute respiratory distress syndrome (ARDS) is a complication of critical illness that is characterized by acute onset, protein rich, pulmonary edema. There is no treatment for ARDS, other than the reduction of additional ventilator induced lung injury. Prediction or earlier recognition of ARDS could result in preventive measurements and might decrease mortality and morbidity. Exhaled breath contains volatile organic compounds (VOCs), a collection of hundreds of small molecules linked to several physiological and pathophysiological processes. Analysis of exhaled breath through gas-chromatography and mass-spectrometry (GC-MS) has resulted in an accurate diagnosis of ARDS in several studies. Most identified markers are linked to lipid peroxidation. Octane is one of the few markers that was validated as a marker of ARDS and is pathophysiologically likely to be increased in ARDS. None of the currently studied breath analysis methods is directly applicable in clinical practice. Two steps have to be taken before any breath test can be allowed into the intensive care unit. External validation in a multi-center study is a prerequisite for any of the candidate breath markers and the breath test should outperform clinical prediction scores. Second, the technology for breath analysis should be adapted so that it is available at a decentralized lab inside the intensive care unit and can be operated by trained nurses, in order to reduce the analysis time. In conclusion, exhaled analysis might be used for the early diagnosis and prediction of ARDS in the near future but several obstacles have to be taken in the coming years. Most of the candidate markers can be linked to lipid peroxidation. Only octane has been validated in a temporal external validation cohort and is, at this moment, the top-ranking breath biomarker for ARDS. PMID:29430450
Donaldsson, Snorri; Falk, Markus; Jonsson, Baldvin; Drevhammar, Thomas
2015-01-01
The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates.
2015-01-01
Background The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Methods Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. Results The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. Conclusion The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates. PMID:26192188
Kuppusamy, Maheshkumar; Dilara, K; Ravishankar, P; Julius, A
2017-01-01
Prāṇāyāma , the fourth limb of ancient aṣṭāṅga yoga consists of breathing techniques which produce various physiological and psychological effects. Though various types of prāṇāyāma and their effects have been scientifically established, Bhrāmarī prāṇāyāma (Bhr.P) is the one whose effects still remain understated. The present study was conducted to find the effects of Bhrāmarī prāṇāyāma practice on pulmonary function in healthy adolescents. Randomized control trial. 90 healthy adolescents including 32 females and 58 males participated in the study. They were randomly divided into Bhr.P group ( n = 45) and Control group ( n = 45) by a simple lottery method. Pulmonary function test was done at baseline and at end of 12 th week using RMS Helios spirometry. Prāṇāyāma group students were trained to do Bhr.P as 3 to 4 breaths/min for 5 min followed by 2 min rest. This was one cycle and in this way, they were instructed to do five cycles each time for 45 minutes five days in a week. Control group students were not allowed to practice any kind of exercise throughout the study period. Student paired and unpaired T tests were used to analyse the intra group and intergroup differences using R statistical software. A significant ( P < 0.05) improvement in all pulmonary function parameters; FVC, FEV1, FEV1/FVC ratio, FEF 25%-75% and PEFR was seen in the Bhr.P group than the control group adolescents. Slow vital capacity (SVC) and Maximum Voluntary Volume (MVV) also showed significant improvement in the prāṇāyāma group. Bhrāmarī Prāṇāyāma practice is effective in improving the pulmonary function among the adolescents which could be utilized for further clinical studies.
DEVELOPMENT OF A SCREENING PROTOCOL TO IDENTIFY INDIVIDUALS WITH DYSFUNCTIONAL BREATHING
Kiesel, Kyle; Rhodes, Tonya; Mueller, Jacob; Waninger, Alyssa; Butler, Robert
2017-01-01
Introduction Dysfunctional breathing (DB) has been linked to health conditions including low back pain and neck pain and adversely effects the musculoskeletal system. Individuals with DB often have decreased pain thresholds and impaired motor control, balance, and movement. No single test or screen identifies DB, which is multi-dimensional, and includes biochemical, biomechanical, and psychophysiological components. Several tools assess and test for DB, but no screen exists to determine whether additional testing and assessment are indicated. Purpose/Background The purpose of this study was to develop a breathing screening procedure that could be utilized by fitness and healthcare providers to screen for the presence of disordered breathing. A diagnostic test study approach was utilized to establish the diagnostic accuracy of the newly developed screen for DB. Methods A convenience sample of 51 subjects (27 females, 27.0 years, BMI 23.3) were included. To test for DB related to the biochemical dimension, end-tidal CO2 (ETCO2) was measured with a capnography unit. To test for DB related to biomechanical dimension, the Hi-Lo test was utilized. To test for DB related to the psychophysiological dimension, the Self Evaluation of Breathing Symptoms Questionnaire (SEBQ) and Nijmegen questionnaires were utilized. Potential screening items that have been shown to be related to DB in previous research and that could be performed by non-health care personnel were utilized to create the index test including activity level, breath hold time (BHT), respiration rate, and the Functional Movement Screen (FMS™). Results There were no strong correlations between the three measures of DB. Five subjects had normal breathing, 14 failed at least one measure, 20 failed at least two, and 12 failed all three. To develop screening items for each dimension, data were examined for association with failure. BHT and a four-item mini-questionnaire were identified as the most closely associated variables with failure of all three dimensions. A BHT of < 25 seconds and four questions were combined and yielded a sensitivity of 0.89 (0.85-0.93) and a specificity of 0.60 (0.18-0.92) for clinical identification of DB. Conclusion Easily obtained clinical measures of BHT and four questions can be utilized to screen for the presence of DB. If the screen is passed, there is an 89% chance that DB is not present. If the screen is failed, further assessment is recommended. Level of Evidence 2b PMID:29181255
Detection of Δ9-tetrahydrocannabinol in exhaled breath collected from cannabis users.
Beck, Olof; Sandqvist, Sören; Dubbelboer, Ilse; Franck, Johan
2011-10-01
Exhaled breath has recently been proposed as a new possible matrix for drugs of abuse testing. A key drug is cannabis, and the present study was aimed at investigating the possibility of detecting tetrahydrocannabinol and tetrahydrocannabinol carboxylic acid in exhaled breath after cannabis smoking. Exhaled breath was sampled from 10 regular cannabis users and 8 controls by directing the exhaled breath by suction through an Empore C(18) disk. The disk was extracted with hexane/ethyl acetate, and the resulting extract was evaporated to dryness and redissolved in 100 μL hexane/ethyl acetate. A 3-μL aliquot was injected onto the LC-MS-MS system and analyzed using positive electrospray ionization and selected reaction monitoring. In samples collected 1-12 h after cannabis smoking, tetrahydrocannabinol was detected in all 10 subjects. The rate of excretion was between 9.0 and 77.3 pg/min. Identification of tetrahydrocannabinol was based on correct retention time relative to tetrahydrocannabinol-d(3) and correct product ion ratio. In three samples, peaks were observed for tetrahydrocannabinol carboxylic acid, but these did not fulfill identification criteria. Neither tetrahydrocannabinol or tetrahydrocannabinol carboxylic acid was detected in the controls. These results confirm older reports that tetrahydrocannabinol is present in exhaled breath following cannabis smoking and extend the detection time from minutes to hours. The results further support the idea that exhaled breath is a promising matrix for drugs-of-abuse testing.
An automated system for pulmonary function testing
NASA Technical Reports Server (NTRS)
Mauldin, D. G.
1974-01-01
An experiment to quantitate pulmonary function was accepted for the space shuttle concept verification test. The single breath maneuver and the nitrogen washout are combined to reduce the test time. Parameters are defined from the forced vital capacity maneuvers. A spirometer measures the breath volume and a magnetic section mass spectrometer provides definition of gas composition. Mass spectrometer and spirometer data are analyzed by a PDP-81 digital computer.
Marcolina, Daniela; De Marzo, Nicoletta; Riccio, Maria Teresa
2011-01-01
Health impairment due to alcohol use and abuse is well known, in terms of relationship with traffic accidents and work accidents. In Italy almost 10 per cent of accidents at work involve intoxicated people injuring themselves and innocent victims. Alcohol abuse is a factor involved in determining severe accidents in the construction industry and epidemiological studies demonstrated a relationship between an elevated alcohol use and severity of accidents. Since in the Province of Belluno alcohol consumption may be elevated also at work, the two Occupational Health Units (SPISAL) in the province organized a campaign of information and surveillance against alcohol consumption at work in the construction industry. This report shows the campaign results, mainly in terms of breath alcohol tests performed in construction workers. After an extensive information campaign we inspected 50 sites, where 105 construction companies were at work, and tested 294 workers by breath alcohol test. No-one refused the test. Only 2.7% construction workers were positive for the breath alcohol test, and the levels were not elevated. This study shows that the construction workers in Belluno Province are responsible drinkers and are well aware of the policy of prohibition of alcohol consumption at work.
NASA Technical Reports Server (NTRS)
Ramirez, M. P.; Sigaloff, K. C.; Kubatina, L. V.; Donahue, M. A.; Venkatesh, A. K.; Albert, M. S.; ALbert, M. S. (Principal Investigator)
2000-01-01
The physiological effects of various hyperpolarized helium and xenon MRI-compatible breathing protocols were investigated in 17 Sprague-Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath-holds of pure noble gas for varying durations, and helium breath-holds preceded by two helium rinses. Alternate-breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous-breaths caused a 31.5% +/- 2.3% decrease in oxygen saturation for helium and a 30.7% +/- 1. 3% decrease for xenon. Breath-hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath-hold, the blood oxygen saturation dropped precipitously to 82% +/- 0.6% for helium, and to 76.5% +/- 7. 4% for xenon. Breath-holds longer than 10 s preceded by pre-rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath-hold and alternate-breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright 2000 John Wiley & Sons, Ltd.
Experimental and modeling study of thermal exposure of a self-contained breathing apparatus (SCBA).
Donnelly, Michelle K; Yang, Jiann C
2015-08-01
An experimental apparatus designed to study firefighter safety equipment exposed to a thermal environment was developed. The apparatus consisted of an elevated temperature flow loop with the ability to heat the air stream up to 200°C. The thermal and flow conditions at the test section were characterized using thermocouples and bi-directional probes. The safety equipment examined in this study was a self-contained breathing apparatus (SCBA), including a facepiece and an air cylinder. The SCBA facepiece was placed on a mannequin headform and coupled to a breathing simulator that was programmed with a prescribed breathing pattern. The entire SCBA assembly was placed in the test section of the flow loop for these thermal exposure experiments. Three air stream temperatures, 100°C, 150°C, and 200°C, were used with the average air speed at the test section set at 1.4m/s and thermal exposure durations up to 1200 s. Measurements were made using type-K bare-bead thermocouples located in the mannequin's mouth and on the outer surface of the SCBA cylinder. The experimental results indicated that increasing the thermal exposure severity and duration increased the breathing air temperatures supplied by the SCBA. Temperatures of breathing air from the SCBA cylinder in excess of 60°C were observed over the course of the thermal exposure conditions used in most of the experiments. A mathematical model for transient heat transfer was developed to complement the thermal exposure experimental study. The model took into consideration forced convective heat transfer, quasi-steady heat conduction through the composite layers of the SCBA cylinder wall, the breathing pattern and action of the breathing simulator, and predicted air temperatures from the thermally exposed SCBA cylinder and temperatures at the outer surface of the SCBA cylinder. Model predictions agreed reasonably well with the experimental measurements. Published by Elsevier Ltd.
ABC versus CAB for cardiopulmonary resuscitation: a prospective, randomized simulator-based trial.
Marsch, Stephan; Tschan, Franziska; Semmer, Norbert K; Zobrist, Roger; Hunziker, Patrick R; Hunziker, Sabina
2013-09-06
After years of advocating ABC (Airway-Breathing-Circulation), current guidelines of cardiopulmonary resuscitation (CPR) recommend CAB (Circulation-Airway-Breathing). This trial compared ABC with CAB as initial approach to CPR from the arrival of rescuers until the completion of the first resuscitation cycle. 108 teams, consisting of two physicians each, were randomized to receive a graphical display of either the ABC algorithm or the CAB algorithm. Subsequently teams had to treat a simulated cardiac arrest. Data analysis was performed using video recordings obtained during simulations. The primary endpoint was the time to completion of the first resuscitation cycle of 30 compressions and two ventilations. The time to execution of the first resuscitation measure was 32 ± 12 seconds in ABC teams and 25 ± 10 seconds in CAB teams (P = 0.002). 18/53 ABC teams (34%) and none of the 55 CAB teams (P = 0.006) applied more than the recommended two initial rescue breaths which caused a longer duration of the first cycle of 30 compressions and two ventilations in ABC teams (31 ± 13 vs.23 ± 6 sec; P = 0.001). Overall, the time to completion of the first resuscitation cycle was longer in ABC teams (63 ± 17 vs. 48 ± 10 sec; P <0.0001). This randomized controlled trial found CAB superior to ABC with an earlier start of CPR and a shorter time to completion of the first 30:2 resuscitation cycle. These findings endorse the change from ABC to CAB in international resuscitation guidelines.
DOT National Transportation Integrated Search
2007-11-01
The National Highway Traffic Safety Administration has found that the percentage of people who refuse to provide breath samples when arrested for Driving While Intoxicated (DWI) varies considerably across States, and this creates a concern in the cri...
(13)C breath tests in personalized medicine: fiction or reality?
Modak, Anil S
2009-11-01
The concept of personalized medicine is gathering momentum as various biomarkers are being discovered and developed to lead to genotype and phenotype diagnostic tests, which will enable physicians to individualize therapy. Noninvasive, rapid (13)C breath tests have the potential to serve as clinically significant diagnostic tools, especially for evaluating the enzyme activity of polymorphic enzymes. This would enable physicians to rapidly identify responders/nonresponders to various drugs primarily metabolized by these enzymes prior to initiation of therapy. With the information on enzyme activity, the physician can prescribe the right drug, at the right dose, at the right time, to the right individual, for the right clinical outcome. However, the promise of the era of personalized medicine, including the novel (13)C breath tests, will have to overcome several regulatory, business and financial hurdles for diagnostic tests to become part of routine mainstream clinical practice over the next decade.
Yuki, Mika; Komazawa, Yoshinori; Kobayashi, Yoshiya; Kusunoki, Maho; Takahashi, Yoshiko; Nakashima, Sayaka; Uno, Goichi; Ikuma, Isao; Shizuku, Toshihiro; Kinoshita, Yoshikazu
2015-12-01
Daikenchuto (DKT), a traditional Japanese herbal medicine, is widely used for treatment of gastrointestinal disorders. We evaluated the efficacy and safety of DKT for abdominal bloating in patients with chronic constipation. To evaluate the efficacy and safety of DKT for the treatment of abdominal bloating. After discontinuing as-needed use of laxatives, 10 patients received oral DKT for 14 days (15 g/d). To evaluate small intestinal bacteria overgrowth (SIBO), a glucose breath test was performed before and after treatment with DKT. Before beginning the treatment, 4 patients (40%) had a diagnosis of SIBO based on a positive glucose breath test result. In both the SIBO and non-SIBO groups, bowel movement frequency and stool form remained unchanged after DKT treatment. For all patients, median total Gastrointestinal Symptoms Rating Scale score and the median Gastrointestinal Symptoms Rating Scale indigestion and constipation subscales were significantly decreased, whereas the median visual analog score for decreased abdominal bloating was significantly increased. Improvements of those symptoms were the same in both the SIBO and non-SIBO groups, indicating that DKT does not have effects on small intestine bacteria. No serious side effects were reported. DKT treatment improved quality of life for patients with chronic constipation regardless of the presence of SIBO and showed no effects on small intestine bacteria. UMIN Clinical Trial Registry identifier: UMIN000008070.
Morning-to-evening differences in oxygen uptake kinetics in short-duration cycling exercise.
Brisswalter, Jeanick; Bieuzen, François; Giacomoni, Magali; Tricot, Véronique; Falgairette, Guy
2007-01-01
This study analyzed diurnal variations in oxygen (O(2)) uptake kinetics and efficiency during a moderate cycle ergometer exercise. Fourteen physically active diurnally active male subjects (age 23+/-5 yrs) not specifically trained at cycling first completed a test to determine their ventilatory threshold (T(vent)) and maximal oxygen consumption (VO(2max)); one week later, they completed four bouts of testing in the morning and evening in a random order, each separated by at least 24 h. For each period of the day (07:00-08:30 h and 19:00-20:30 h), subjects performed two bouts. Each bout was composed of a 5 min cycling exercise at 45 W, followed after 5 min rest by a 10 min cycling exercise at 80% of the power output associated with T(vent). Gas exchanges were analyzed breath-by-breath and fitted using a mono-exponential function. During moderate exercise, the time constant and amplitude of VO(2) kinetics were significantly higher in the morning compared to the evening. The net efficiency increased from the morning to evening (17.3+/-4 vs. 20.5+/-2%; p<0.05), and the variability of cycling cadence was greater during the morning than evening (+34%; p<0.05). These findings suggest that VO(2) responses are affected by the time of day and could be related to variability in muscle activity pattern.
Quiet breathing in hindlimb casted mice.
Receno, Candace N; Roffo, Katelynn E; Mickey, Marisa C; DeRuisseau, Keith C; DeRuisseau, Lara R
2018-06-07
The hindlimb casting model was developed to study skeletal muscle reloading following a period of unloading. It is unknown if ventilation parameters of mice are affected by the casting model. We tested the hypothesis that hindlimb casted mice have similar ventilatory patterns compared to mice with the casts removed. Male CD-1 mice underwent 14 days of hindlimb immobilization via plaster casting. Breathing parameters were obtained utilizing unrestrained barometric plethysmography (UBP). Breathing traces were analyzed with Ponemah software for breathing frequency, tidal volume (TV), and minute ventilation (MV). Frequency, TV and MV did not show any differences in quiet breathing patterns during or post-casting in mice. Thus, the hindlimb casting model does not complicate breathing during and after casting and should not interfere with the unloading and reloading of skeletal muscle. Copyright © 2018 Elsevier B.V. All rights reserved.
Blaikie, Tom P J; Edge, Julie A; Hancock, Gus; Lunn, Daniel; Megson, Clare; Peverall, Rob; Richmond, Graham; Ritchie, Grant A D; Taylor, David
2014-11-25
Previous studies have suggested that breath gases may be related to simultaneous blood glucose and blood ketone levels in adults with type 2 and type 1 diabetes. The aims of this study were to investigate these relationships in children and young people with type 1 diabetes in order to assess the efficacy of a simple breath test as a non-invasive means of diabetes management. Gases were collected in breath bags and measurements were compared with capillary blood glucose and ketone levels taken at the same time on a single visit to a routine hospital clinic in 113 subjects (59 male, age 7 years 11 months-18 years 3 months) with type 1 diabetes. The patients were well-controlled with relatively low concentrations of the blood ketone measured (β hydroxybutyrate, 0-0.4 mmol l(-1)). Breath acetone levels were found to increase with blood β hydroxybutyrate levels and a significant relationship was found between the two (Spearman's rank correlation ρ = 0.364, p < 10(-4)). A weak positive relationship was found between blood glucose and breath acetone (ρ = 0.16, p = 0.1), but led to the conclusion that single breath measurements of acetone do not provide a good measure of blood glucose levels in this cohort. This result suggests a potential to develop breath gas analysis to provide an alternative to blood testing for ketone measurement, for example to assist with the management of type 1 diabetes.
[Frequency of rhinitis and orofacial disorders in patients with dental malocclusion].
Imbaud, Tamara Christine de Souza; Mallozi, Márcia Carvalho; Domingos, Vanda Beatriz Teixeira Coelho; Solé, Dirceu
2016-06-01
To describe the frequency and etiology of rhinitis, oral breathing, types of malocclusion and orofacial disorders in patients treated for dental malocclusion. Patients with poor dental occlusion (n=89, 8-15 years) undergoing orthodontic treatment at the Postgraduate Orthodontics Center (Sao Paulo, Brazil) participated in the study. Rhinitis and oral breathing were diagnosed by anamnesis, clinical assessment and allergic etiology of rhinitis through immediate hypersensitivity skin prick test (SPT) with airborne allergens. The association between types of breathing (oral or nasal), rhinitis and types of dental malocclusion, bruxism and cephalometric alterations (increased Y axis of facial growth) compared to standard cephalometric tracing (Escola de Odontologia da Universidade de São Paulo) were assessed. The frequency of rhinitis in patients with dental malocclusion was 76.4% (68), and, of these, 81.7% were allergic (49/60 positive skin prick test), whereas the frequency of oral breathing was 62.9%. There was a significant association between an increased Y axis of facial growth and oral breathing (p<0.001), as well as between oral breathing and rhinitis (p=0.009). There was no association between rhinitis and bruxism. The frequency of rhinitis in children with dental malocclusion is higher than that in the general population, which is approximately 30%. Patients with oral breathing have a tendency to a dolichofacial growth pattern (increased Y axis of facial growth). In patients with rhinitis, regardless of the presence of oral breathing, the dolichofacial growth tendency was not observed. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.
Do elite breath-hold divers suffer from mild short-term memory impairments?
Billaut, François; Gueit, Patrice; Faure, Sylvane; Costalat, Guillaume; Lemaître, Frédéric
2018-03-01
Repeated apneas are associated with severe hypoxemia that may ultimately lead to loss of consciousness in some breath-hold divers. Despite increasing number of practitioners, the relationship between apnea-induced hypoxia and neurocognitive functions is still poorly understood in the sport of free diving. To shed light onto this phenomenon, we examined the impact of long-term breath-hold diving training on attentional processing, short-term memory, and long-term mnesic and executive functions. Thirty-six men matched for age, height, and weight were separated into the following 3 groups: (i) 12 elite breath-hold divers (EBHD), mean static apnea best time 371 s, 105 months mean apnea experience; (ii) 12 novice breath-hold divers, mean best time 243 s, 8.75 months mean apnea experience; and (iii) 12 physical education students with no breath-hold diving experience; all of these participants performed varied written and computerized neuropsychological tasks. Compared with the 2 other groups, the EBHD group was slower to complete the interference card during a Stroop test (F [1,33] = 4.70, p < 0.05), and presented more errors on the interference card (F [1,33] = 2.96, p < 0.05) and a lower total interference score (F [1,33] = 5.64, p < 0.05). The time to complete the interference card test was positively correlated with maximal static apnea duration (r = 0.73, p < 0.05) and the number of years of breath-hold diving training (r = 0.79, p < 0.001). These findings suggest that breath-hold diving training over several years may cause mild, but persistent, short-term memory impairments.
2016-10-01
Cognition, Quality of Life, and Cardiovascular Disease PRINCIPAL INVESTIGATOR: Shirin Shafazand, MD, MS CONTRACTING ORGANIZATION: University of Miami...with positive airway pressure (PAP) will improve cognitive impairment, sleep quality, quality of life, and cardiovascular disease (CVD) surrogate...Randomized Controlled Trial of Treatment Impact on Cognition, Quality of Life, and Cardiovascular Disease Shirin Shafazand, MD, MS Nothing listed 12
Getting the Facts on Food Allergy Testing
... ing, vomiting or trouble breathing after eating or coming into contact with a certain food, you may ... swelling, vomiting or trouble breathing after eating or coming into contact with certain foods, it’s important to ...
A dual mode breath sampler for the collection of the end-tidal and dead space fractions.
Salvo, P; Ferrari, C; Persia, R; Ghimenti, S; Lomonaco, T; Bellagambi, F; Di Francesco, F
2015-06-01
This work presents a breath sampler prototype automatically collecting end-tidal (single and multiple breaths) or dead space air fractions (multiple breaths). This result is achieved by real time measurements of the CO2 partial pressure and airflow during the expiratory and inspiratory phases. Suitable algorithms, used to control a solenoid valve, guarantee that a Nalophan(®) bag is filled with the selected breath fraction even if the subject under test hyperventilates. The breath sampler has low pressure drop (<0.5 kPa) and uses inert or disposable components to avoid bacteriological risk for the patients and contamination of the breath samples. A fully customisable software interface allows a real time control of the hardware and software status. The performances of the breath sampler were evaluated by comparing (a) the CO2 partial pressure calculated during the sampling with the CO2 pressure measured off-line within the Nalophan(®) bag; (b) the concentrations of four selected volatile organic compounds in dead space, end-tidal and mixed breath fractions. Results showed negligible deviations between calculated and off-line CO2 pressure values and the distributions of the selected compounds into dead space, end-tidal and mixed breath fractions were in agreement with their chemical-physical properties. Copyright © 2015. Published by Elsevier Ltd.
Respiratory muscle function in infants with spinal muscular atrophy type I.
Finkel, Richard S; Weiner, Daniel J; Mayer, Oscar H; McDonough, Joseph M; Panitch, Howard B
2014-12-01
To determine the feasibility and safety of respiratory muscle function testing in weak infants with a progressive neuromuscular disorder. Respiratory insufficiency is the major cause of morbidity and mortality in infants with spinal muscular atrophy type I (SMA-I). Tests of respiratory muscle strength, endurance, and breathing patterns can be performed safely in SMA-I infants. Useful data can be collected which parallels the clinical course of pulmonary function in SMA-I. An exploratory study of respiratory muscle function testing and breathing patterns in seven infants with SMA-I seen in our neuromuscular clinic. Measurements were made at initial study visit and, where possible, longitudinally over time. We measured maximal inspiratory (MIP) and transdiaphragmatic pressures, mean transdiaphragmatic pressure, airway occlusion pressure at 100 msec of inspiration, inspiratory and total respiratory cycle time, and aspects of relative thoracoabdominal motion using respiratory inductive plethysmography (RIP). The tension time index of the diaphragm and of the respiratory muscles, phase angle (Φ), phase relation during the total breath, and labored breathing index were calculated. Age at baseline study was 54-237 (median 131) days. Reliable data were obtained safely for MIP, phase angle, labored breathing index, and the invasive and non-invasive tension time indices, even in very weak infants. Data obtained corresponded to the clinical estimate of severity and predicted the need for respiratory support. The testing employed was both safe and feasible. Measurements of MIP and RIP are easily performed tests that are well tolerated and provide clinically useful information for infants with SMA-I. © 2014 Wiley Periodicals, Inc.
El Shayeb, Mohamed; Topfer, Leigh-Ann; Stafinski, Tania; Pawluk, Lawrence; Menon, Devidas
2014-01-01
Background: Greater awareness of sleep-disordered breathing and rising obesity rates have fueled demand for sleep studies. Sleep testing using level 3 portable devices may expedite diagnosis and reduce the costs associated with level 1 in-laboratory polysomnography. We sought to assess the diagnostic accuracy of level 3 testing compared with level 1 testing and to identify the appropriate patient population for each test. Methods: We conducted a systematic review and meta-analysis of comparative studies of level 3 versus level 1 sleep tests in adults with suspected sleep-disordered breathing. We searched 3 research databases and grey literature sources for studies that reported on diagnostic accuracy parameters or disease management after diagnosis. Two reviewers screened the search results, selected potentially relevant studies and extracted data. We used a bivariate mixed-effects binary regression model to estimate summary diagnostic accuracy parameters. Results: We included 59 studies involving a total of 5026 evaluable patients (mostly patients suspected of having obstructive sleep apnea). Of these, 19 studies were included in the meta-analysis. The estimated area under the receiver operating characteristics curve was high, ranging between 0.85 and 0.99 across different levels of disease severity. Summary sensitivity ranged between 0.79 and 0.97, and summary specificity ranged between 0.60 and 0.93 across different apnea–hypopnea cut-offs. We saw no significant difference in the clinical management parameters between patients who underwent either test to receive their diagnosis. Interpretation: Level 3 portable devices showed good diagnostic performance compared with level 1 sleep tests in adult patients with a high pretest probability of moderate to severe obstructive sleep apnea and no unstable comorbidities. For patients suspected of having other types of sleep-disordered breathing or sleep disorders not related to breathing, level 1 testing remains the reference standard. PMID:24218531
2010-01-01
Background The objective of this study was to investigate whether the 13C-phenylalanine breath test could be useful for the evaluation of hepatic function in elderly volunteers and patients with chronic hepatitis B and liver cirrhosis. Methods L-[1-13C] phenylalanine was administered orally at a dose of 100 mg to 55 elderly patients with liver cirrhosis, 30 patients with chronic hepatitis B and 38 elderly healthy subjects. The breath test was performed at 8 different time points (0, 10, 20, 30, 45, 60, 90, 120 min) to obtain the values of Delta over baseline, percentage 13CO2 exhalation rate and cumulative excretion (Cum). The relationships of the cumulative excretion with the 13C-%dose/h and blood biochemical parameters were investigated. Results The 13C-%dose/h at 20 min and 30 min combined with the cumulative excretion at 60 min and 120 min correlated with hepatic function tests, serum albumin, hemoglobin, platelet and Child-Pugh score. Prothrombin time, total and direct bilirubin were significantly increased, while serum albumin, hemoglobin and platelet, the cumulative excretion at 60 min and 120 min values decreased by degrees of intensity of the disease in Child-Pugh A, B, and C patients (P < 0.01). Conclusions The 13C-phenylalanine breath test can be used as a non-invasive assay to evaluate hepatic function in elderly patients with liver cirrhosis. The 13C-%dose/h at 20 min, at 30 min and cumulative excretion at 60 min may be the key value for determination at a single time-point. 13C-phenylalanine breath test is safe and helpful in distinguishing different stages of hepatic dysfunction for elderly cirrhosis patients. PMID:20459849
A probability-based multi-cycle sorting method for 4D-MRI: A simulation study
Liang, Xiao; Yin, Fang-Fang; Liu, Yilin; Cai, Jing
2016-01-01
Purpose: To develop a novel probability-based sorting method capable of generating multiple breathing cycles of 4D-MRI images and to evaluate performance of this new method by comparing with conventional phase-based methods in terms of image quality and tumor motion measurement. Methods: Based on previous findings that breathing motion probability density function (PDF) of a single breathing cycle is dramatically different from true stabilized PDF that resulted from many breathing cycles, it is expected that a probability-based sorting method capable of generating multiple breathing cycles of 4D images may capture breathing variation information missing from conventional single-cycle sorting methods. The overall idea is to identify a few main breathing cycles (and their corresponding weightings) that can best represent the main breathing patterns of the patient and then reconstruct a set of 4D images for each of the identified main breathing cycles. This method is implemented in three steps: (1) The breathing signal is decomposed into individual breathing cycles, characterized by amplitude, and period; (2) individual breathing cycles are grouped based on amplitude and period to determine the main breathing cycles. If a group contains more than 10% of all breathing cycles in a breathing signal, it is determined as a main breathing pattern group and is represented by the average of individual breathing cycles in the group; (3) for each main breathing cycle, a set of 4D images is reconstructed using a result-driven sorting method adapted from our previous study. The probability-based sorting method was first tested on 26 patients’ breathing signals to evaluate its feasibility of improving target motion PDF. The new method was subsequently tested for a sequential image acquisition scheme on the 4D digital extended cardiac torso (XCAT) phantom. Performance of the probability-based and conventional sorting methods was evaluated in terms of target volume precision and accuracy as measured by the 4D images, and also the accuracy of average intensity projection (AIP) of 4D images. Results: Probability-based sorting showed improved similarity of breathing motion PDF from 4D images to reference PDF compared to single cycle sorting, indicated by the significant increase in Dice similarity coefficient (DSC) (probability-based sorting, DSC = 0.89 ± 0.03, and single cycle sorting, DSC = 0.83 ± 0.05, p-value <0.001). Based on the simulation study on XCAT, the probability-based method outperforms the conventional phase-based methods in qualitative evaluation on motion artifacts and quantitative evaluation on tumor volume precision and accuracy and accuracy of AIP of the 4D images. Conclusions: In this paper the authors demonstrated the feasibility of a novel probability-based multicycle 4D image sorting method. The authors’ preliminary results showed that the new method can improve the accuracy of tumor motion PDF and the AIP of 4D images, presenting potential advantages over the conventional phase-based sorting method for radiation therapy motion management. PMID:27908178
An analysis of estimation of pulmonary blood flow by the single-breath method
NASA Technical Reports Server (NTRS)
Srinivasan, R.
1986-01-01
The single-breath method represents a simple noninvasive technique for the assessment of capillary blood flow across the lung. However, this method has not gained widespread acceptance, because its accuracy is still being questioned. A rigorous procedure is described for estimating pulmonary blood flow (PBF) using data obtained with the aid of the single-breath method. Attention is given to the minimization of data-processing errors in the presence of measurement errors and to questions regarding a correction for possible loss of CO2 in the lung tissue. It is pointed out that the estimations are based on the exact solution of the underlying differential equations which describe the dynamics of gas exchange in the lung. The reported study demonstrates the feasibility of obtaining highly reliable estimates of PBF from expiratory data in the presence of random measurement errors.
Barletta, Michele; Almondia, Donna; Williams, Jamie; Crochik, Sonia; Hofmeister, Erik
2014-10-01
This study documents the degree of positional atelectasis in sedated dogs receiving 100% oxygen (O(2)) versus room air. Initial lateral recumbency was determined by an orthopedic study and initial treatment (O(2) or room air) was randomized. Each dog was maintained in lateral recumbency for 15 min, at which time ventrodorsal (VD) and opposite lateral thoracic radiographs were obtained. Each dog was then maintained in the opposite lateral recumbency and received the other treatment for 15 min, followed by a VD and opposite lateral radiograph. Radiographs were scored for severity of pulmonary pattern and mediastinal shift by 3 radiologists. Dogs breathing O(2) had significantly higher scores than dogs breathing room air. If radiographically detectable dependent atelectasis is present, repeat thoracic images following manual positive ventilation and/or position change to the opposite lateral recumbency should be made to rule out the effect of O(2) positional atelectasis and avoid misdiagnosis.
Barbosa, Alexandre C; Martins, Fábio M; Silva, Angélica F; Coelho, Ana C; Intelangelo, Leonardo; Vieira, Edgar R
2017-11-01
Barbosa, AC, Martins, FM, Silva, AF, Coelho, AC, Intelangelo, L, and Vieira, ER. Activity of lower limb muscles during squat with and without abdominal drawing-in and Pilates breathing. J Strength Cond Res 31(11): 3018-3023, 2017-The purpose of this study was to assess the effects of abdominal drawing-in and Pilates breathing on the activity of lower limb muscles during squats. Adults (n = 13, 22 ± 3 years old) with some Pilates experience performed three 60° squats under each of the following conditions in a random order: (I) normal breathing, (II) drawing-in maneuver with normal breathing, and (III) drawing-in maneuver with Pilates breathing. Peak-normalized surface electromyography of the rectus femoris, biceps femoris, gastrocnemius medialis, and tibialis anterior during the knee flexion and extension phases of squat exercises was analyzed. There were significant differences among the conditions during the knee flexion phase for the rectus femoris (p = 0.001), biceps femoris (p = 0.038), and tibialis anterior (p = 0.001), with increasing activation from conditions I to III. For the gastrocnemius medialis, there were significant differences among the conditions during the knee extension phase (p = 0.023), with increased activity under condition I. The rectus and biceps femoris activity was higher during the extension vs. flexion phase under conditions I and II. The tibialis anterior activity was higher during the flexion compared with the extension phase under all conditions, and the medial gastrocnemius activity was higher during the extension phase under condition I. Doing squats with abdominal drawing-in and Pilates breathing resulted in increased rectus, biceps femoris, and tibialis anterior activity during the flexion phase, increasing movement stability during squat exercises.
Does diurnal variation in cough reflex testing exist in healthy young adults?
Perry, Sarah; Huckabee, Maggie-Lee
2017-05-01
The aim of this study was to investigate whether diurnal variation in cough reflex sensitivity exists in healthy young adults when a tidal-breathing method is used. Fifty-three participants (19-37 years) underwent cough reflex testing on two occasions: once in the morning (between 9 am - midday) and once in the afternoon (between 2-5 pm). The order of testing was counter-balanced. Within each assessment, participants inhaled successively higher citric acid concentrations via a facemask, with saline solution randomly interspersed to control for a placebo response. The lowest concentration that elicited a reflexive cough response was recorded. Morning cough thresholds (mean=0.6mol/L) were not different from afternoon cough thresholds (mean=0.6mol/L), p=0.16, T=101, r=-0.14. We found no evidence of diurnal variability in cough reflex testing. There was, however, an order effect irrespective of time of day, confirming that healthy participants are able to volitionally modulate their cough response. Copyright © 2017 Elsevier B.V. All rights reserved.
Zapata-Castilleja, Carlos A; Montes-Tapia, Fernando F; Treviño-Garza, Consuelo; Martínez-Cobos, María C; García-Cantú, Jesús; Arenas-Fabbri, Vincenzo; de la O-Escamilla, Norma; de la O-Cavazos, Manuel
2017-04-01
Lactose intolerance is a common disease in pediatrics, and its wrong diagnosis will lead to morbidity. The primary objective of this study was to assess the usefulness of an increased waist circumference during the hydrogen breath test as a predictor of lactose intolerance. The secondary objective was to analyze the impact of body mass index, waist circumference measurement, and age on the abdominal distension of patients with lactose intolerance. A total of 138 subjects aged 3 to 15 years were included. They underwent serial measurements of the waist circumference and hydrogen levels in the breath every 30 minutes over 3 hours during the hydrogen breath test. Out of the entire sample, 35 (25.4%) patients had lactose intolerance. An increase of 0.85 cm in waist circumference compared to the baseline waist circumference results in a sensitivity of 88% and a specificity of 85% to predict lactose intolerance (odds ratio: 42.14, 95% confidence interval: 13.08-135.75, p ≤ 0.001). The body mass index and waist circumference measurement did not affect abdominal distension (p= not significant); however, age modified the time of distension. A 0.85 cm increase in waist circumference compared to the baseline waist circumference during the hydrogen breath test is a useful parameter for the diagnosis of lactose intolerance in pediatrics. Variations in relation to body mass index and waist circumference did not affect the usefulness of an increased waist circumference, unlike age.
Spike-Timing of Orbitofrontal Neurons Is Synchronized With Breathing.
Kőszeghy, Áron; Lasztóczi, Bálint; Forro, Thomas; Klausberger, Thomas
2018-01-01
The orbitofrontal cortex (OFC) has been implicated in a multiplicity of complex brain functions, including representations of expected outcome properties, post-decision confidence, momentary food-reward values, complex flavors and odors. As breathing rhythm has an influence on odor processing at primary olfactory areas, we tested the hypothesis that it may also influence neuronal activity in the OFC, a prefrontal area involved also in higher order processing of odors. We recorded spike timing of orbitofrontal neurons as well as local field potentials (LFPs) in awake, head-fixed mice, together with the breathing rhythm. We observed that a large majority of orbitofrontal neurons showed robust phase-coupling to breathing during immobility and running. The phase coupling of action potentials to breathing was significantly stronger in orbitofrontal neurons compared to cells in the medial prefrontal cortex. The characteristic synchronization of orbitofrontal neurons with breathing might provide a temporal framework for multi-variable processing of olfactory, gustatory and reward-value relationships.
Reychler, Gregory; Uribe Rodriguez, Valeska; Hickmann, Cheryl Elizabeth; Tombal, Bertrand; Laterre, Pierre-François; Feyaerts, Axel; Roeseler, Jean
2018-02-27
Impairment of global and regional pulmonary ventilations is a well-known consequence of general anesthesia. Positive expiratory pressure (PEP) or incentive spirometry (IS) is commonly prescribed, albeit their efficacy is poorly demonstrated. The aim of this study was to assess the effects of PEP and IS on lung ventilation and recruitment in patients after surgery involving anesthesia using electrical impedance tomography (EIT). Ten male subjects (age = 61.2 ± 16.3 years; BMI = 25.3 ± 3.8 kg/m 2 ), free of pulmonary disease before being anesthetized, were recruited. Two series of manoeuvers (PEP and volume-oriented IS) were randomly performed with quiet breathing interposed between these phases. Pulmonary ventilation (ΔEELVVT (i - e)) and recruitment (ΔEELI) were evaluated continuously in a semi-seated position during all phases by EIT. Comparisons between rest and treatment were performed by Wilcoxon signed rank test. Rest phases were compared by a mixed ANOVA. Bonferroni method was used for post-hoc comparisons. ΔEELVVT (i - e) and ΔEELI were significantly increased by both techniques (+422% [p < 0.001]; +138% [p = 0.040] and +296% [p < 0.001]; +638% [p < 0.001] for PEP and IS, respectively). No difference was observed between both manoeuvers neither on ventilation nor on recruitment. This positive effect disappeared during the quiet breathing phases. IS and PEP improved ventilation and recruitment instantaneously without remnant effect after stopping the exercise.
Hourani, Laurel; Tueller, Stephen; Kizakevich, Paul; Lewis, Gregory; Strange, Laura; Weimer, Belinda; Bryant, Stephanie; Bishop, Ellen; Hubal, Robert; Spira, James
2016-09-01
The objective of this pilot study was to design, develop, and evaluate a predeployment stress inoculation training (PRESIT) preventive intervention to enable deploying personnel to cope better with combat-related stressors and mitigate the negative effects of trauma exposure. The PRESIT program consisted of three predeployment training modules: (1) educational materials on combat and operational stress control, (2) coping skills training involving focused and relaxation breathing exercises with biofeedback, and (3) exposure to a video multimedia stressor environment to practice knowledge and skills learned in the first two modules. Heart rate variability assessed the degree to which a subset of participants learned the coping skills. With a cluster randomized design, data from 351 Marines randomized into PRESIT and control groups were collected at predeployment and from 259 of these who responded to surveys on return from deployment. Findings showed that the PRESIT group reduced their physiological arousal through increased respiratory sinus arrhythmia during and after breathing training relative to controls. Logistic regression, corrected for clustering at the platoon level, examined group effects on post-traumatic stress disorder (PTSD) as measured by the Post-traumatic Stress Checklist after controlling for relevant covariates. Results showed that PRESIT protected against PTSD among Marines without baseline mental health problems. Although limited by a small number of participants who screened positive for PTSD, this study supports the benefits of PRESIT as a potential preventive strategy in the U.S. military personnel. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Cagini, C; Giordanelli, A; Fiore, T; Giardinieri, R; Malici, B; De Medio, G E; Pelli, M A; De Bellis, F; Capodicasa, E
2011-01-01
A variety of factors have been implicated in the pathogenesis of age-related macular degeneration (ARMD), and oxidative stress plays an important role in the onset and progression of the disease. Breath ethane is now considered a specific and non-invasive test for determining and monitoring the trend of lipid peroxidation and free radical-induced damage in vivo. This test provides an index of the patients' overall oxidative stress level. We evaluated the breath ethane concentration in exhaled air in patients with advanced ARMD. In this study, we enrolled 13 patients with advanced ARMD and a control group, and a breath analysis was carried out by gas chromatography. The mean ethane level in the ARMD patients was 0.82 ± 0.93 nmol/l (range: 0.01-2.7 nmol/l) and the mean ethane value in the control group was 0.12 ± 0.02 nmol/l (range: 0.08-0.16 nmol/l). The difference between the values of the 2 groups was statistically significant (p < 0.005). Receiver operating characteristic analysis showed an elevated area under the curve (0.831; 95% CI: 0.634-0.948), with a significance level of p < 0.0014 (area = 0.5). These preliminary results seem to indicate that breath ethane levels are higher in most patients with ARMD. The breath ethane test could thus be a useful method for evaluating the level of oxidative stress in patients with ARMD. To our knowledge, there are no data on this type of analysis applied to ARMD. Copyright © 2011 S. Karger AG, Basel.
Shulman, Robert J; Hollister, Emily B; Cain, Kevin; Czyzewski, Danita I; Self, Mariella M; Weidler, Erica M; Devaraj, Sridevi; Luna, Ruth Ann; Versalovic, James; Heitkemper, Margaret
2017-05-01
We sought to determine the efficacy of psyllium fiber treatment on abdominal pain and stool patterns in children with irritable bowel syndrome (IBS). We evaluated effects on breath hydrogen and methane production, gut permeability, and microbiome composition. We also investigated whether psychological characteristics of children or parents affected the response to treatment. We performed a randomized, double-blind trial of 103 children (mean age, 13 ± 3 y) with IBS seen at primary or tertiary care settings. After 2 weeks on their habitual diet, children began an 8-day diet excluding carbohydrates thought to cause symptoms of IBS. Children with ≥75% improvement in abdominal pain were excluded (n = 17). Children were assigned randomly to groups given psyllium (n = 37) or placebo (maltodextrin, n = 47) for 6 weeks. Two-week pain and stool diaries were compared at baseline and during the final 2 weeks of treatment. We assessed breath hydrogen and methane production, intestinal permeability, and the composition of the microbiome before and after administration of psyllium or placebo. Psychological characteristics of children were measured at baseline. Children in the psyllium group had a greater reduction in the mean number of pain episodes than children in the placebo group (mean reduction of 8.2 ± 1.2 after receiving psyllium vs mean reduction of 4.1 ± 1.3 after receiving placebo; P = .03); the level of pain intensity did not differ between the groups. Psychological characteristics were not associated with response. At the end of the study period, the percentage of stools that were normal (Bristol scale scores, 3-5), breath hydrogen or methane production, intestinal permeability, and microbiome composition were similar between groups. Psyllium fiber reduced the number of abdominal pain episodes in children with IBS, independent of psychological factors. Psyllium did not alter breath hydrogen or methane production, gut permeability, or microbiome composition. ClinicalTrials.gov no: NCT00526903. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Arora, Suman; Gupta, Priyanka; Arya, Virender Kumar; Bhatia, Nidhi
Efficacy of preoxygenation depends upon inspired oxygen concentration, its flow rate, breathing system configuration and patient characteristics. We hypothesized that in actual clinical scenario, where breathing circuit is not primed with 100% oxygen, patients may need more time to achieve EtO 2 ≥90%, and this duration may be different among various breathing systems. We thus studied the efficacy of preoxygenation using unprimed Mapleson A, Bain's and Circle system with tidal volume breathing at oxygen flow rates of 5L.min -1 and 10L.min -1 . Patients were randomly allocated into one of the six groups, wherein they were preoxygenated using either Mapleson A, Bain's or Circle system at O 2 flow rate of either 5L.min -1 or 10L.min -1 . The primary outcome measure of our study was the time taken to achieve EtO 2 ≥90% at 5 and 10L.min -1 flow rates. At oxygen flow rate of 5L.min -1 , time to reach EtO 2 ≥90% was significantly longer with Bain's system (3.7±0.67min) than Mapleson A and Circle system (2.9±0.6, 3.3±0.97min, respectively). However at oxygen flow rate of 10L.min -1 this time was significantly shorter and comparable among all the three breathing systems (2.33±0.38min with Mapleson, 2.59±0.50min with Bain's and 2.60±0.47min with Circle system). With spontaneous normal tidal volume breathing at oxygen flow rate of 5L.min -1 , Mapleson A can optimally preoxygenate patients within 3min while Bain's and Circle system require more time. However at O 2 flow rate of 10L.min -1 all the three breathing systems are capable of optimally preoxygenating the patients in less than 3min. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
de Oliveira, Sergius A R; Lucio, Lorena M C; Modolo, Norma S P; Hayashi, Yoko; Braz, Mariana G; de Carvalho, Lídia R; Braz, Leandro G; Braz, José Reinaldo C
2017-01-01
During anesthesia, as compared with intensive care, the time of the tracheal intubation is much shorter. An inhaled gas minimum humidity of 20 mgH2O.L-1 is recommended to reduce the deleterious effects of dry gas on the airways during anesthesia with tracheal intubation. The Fabius GS Premium® anesthesia workstation (Dräger Medical, Lübeck, Germany) has a built-in hotplate to heat gases in the breathing circuit. A heat and moisture exchanger (HME) is used to further heat and humidify the inhaled gas. The humidity of the gases in the breathing circuit is influenced by the ambient temperature. We compared the humidity of the inhaled gases from a low-flow Fabius anesthesia workstation with or without thermal insulation (TI) of the breathing circuit and with or without an HME. We conducted a prospective randomized trial in 41 adult female patients who underwent elective abdominal surgery. The patients were allocated into four groups according to the devices used to ventilate their lungs using a Dräger Fabius anesthesia workstation with a low gas flow (1 L.min-1): control, with TI, with an HME or with TI and an HME (TIHME). The mean temperature and humidity of the inhaled gases were measured during 2-h after connecting the patients to the breathing circuit. The mean inhaled gas temperature and absolute humidity were higher in the HME (29.2±1.3°C; 28.1±2.3 mgH2O·L-1) and TIHME (30.1±1.2°C; 29.4±2.0 mgH2O·L-1) groups compared with the control (27.5±1.0°C; 25.0±1.8 mgH2O·L-1) and TI (27.2±1.1°C; 24.9±1.8 mgH2O·L-1) groups (P = 0.003 and P<0.001, respectively). The low-flow Fabius GS Premium breathing circuit provides the minimum humidity level of inhaled gases to avoid damage to the tracheobronchial epithelia during anesthesia. TI of the breathing circuit does not increase the humidity of the inhaled gases, whereas inserting an HME increases the moisture of the inhaled gases closer to physiological values.
Siddique, Haamid H; Olson, Raymond H; Parenti, Connie M; Rector, Thomas S; Caldwell, Michael; Dewan, Naresh A; Rice, Kathryn L
2012-01-01
Most interventions aimed at reducing hospitalizations and emergency department (ED) visits in patients with chronic obstructive pulmonary disease (COPD) have employed resource-intense programs in high-risk individuals. Although COPD is a progressive disease, little is known about the effectiveness of proactive interventions aimed at preventing hospitalizations and ED visits in the much larger population of low-risk (no known COPD-related hospitalizations or ED visits in the prior year) patients, some of whom will eventually become high-risk. We tested the effect of a simple educational and self-efficacy intervention (n = 2243) versus usual care (n = 2182) on COPD/breathing-related ED visits and hospitalizations in a randomized study of low-risk patients at three Veterans Affairs (VA) medical centers in the upper Midwest. Administrative data was used to track VA admissions and ED visits. A patient survey was used to determine health-related events outside the VA. Rates of COPD-related VA hospitalizations in the education and usual care group were not significantly different (3.4 versus 3.6 admissions per 100 person-years, respectively; 95% CI of difference -1.3 to 1.0, P = 0.77). The much higher patient-reported rates of non-VA hospitalizations for breathing-related problems were lower in the education group (14.0 versus 19.0 per 100 person-years; 95% CI -8.6 to -1.4, P = 0.006). Rates of COPD-related VA ED visits were not significantly different (6.8 versus 5.3; 95% CI -0.1 to 3.0, P = 0.07), nor were non-VA ED visits (32.4 versus 36.5; 95% CI -9.3 to 1.1, P = 0.12). All-cause VA admission and ED rates did not differ. Mortality rates (6.9 versus 8.3 per 100 person-years, respectively; 95% CI -3.0 to 0.4, P = 0.13) did not differ. An educational intervention that is practical for large numbers of low-risk patients with COPD may reduce the rate of breathing-related hospitalizations. Further research that more closely tracks hospitalizations to non-VA facilities is needed to confirm this finding.
Yoga leads to multiple physical improvements after stroke, a pilot study.
Schmid, Arlene A; Miller, Kristine K; Van Puymbroeck, Marieke; DeBaun-Sprague, Erin
2014-12-01
To assess change in physical functioning (pain, range of motion (ROM), strength, and endurance) after 8 weeks of therapeutic-yoga. Planned analyses of data from a randomized pilot study of yoga after stroke. University-based research laboratory. People with chronic stroke (N=47) randomized to therapeutic-yoga (n=37) or wait-list control (n=10). 16 sessions of therapeutic yoga (twice a week/8 weeks). Yoga was delivered in a standardized and progressive format with postures, breathing, and meditation, and relaxation in sitting, standing, and supine. Pain was assessed with the PEG, a 3-item functional measure of the interference of pain. ROM included neck and hip active and passive ROM measurements). Upper and lower extremity strength were assessed with the arm curl test and chair-to-stand test, respectively. Endurance was assessed with the 6-minute walk and modified 2-min step test. After a Bonferroni Correction, pain, neck ROM, hip passive ROM, upper extremity strength, and the 6-min walk scores all significantly improved after 8 weeks of engaging in yoga. No changes occurred in the wait-list control group. A group therapeutic-yoga intervention may improve multiple aspects of physical functioning after stroke. Such an intervention may be complementary to traditional rehabilitation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ferdinands, Jill M; Crawford, Carol A Gotway; Greenwald, Roby; Van Sickle, David; Hunter, Eric; Teague, W Gerald
2008-01-01
Background Vigorous outdoors exercise during an episode of air pollution might cause airway inflammation. The purpose of this study was to examine the effects of vigorous outdoor exercise during peak smog season on breath pH, a biomarker of airway inflammation, in adolescent athletes. Methods We measured breath pH both pre- and post-exercise on ten days during peak smog season in 16 high school athletes engaged in daily long-distance running in a downwind suburb of Atlanta. The association of post-exercise breath pH with ambient ozone and particulate matter concentrations was tested with linear regression. Results We collected 144 pre-exercise and 146 post-exercise breath samples from 16 runners (mean age 14.9 years, 56% male). Median pre-exercise breath pH was 7.58 (interquartile range: 6.90 to 7.86) and did not change significantly after exercise. We observed no significant association between ambient ozone or particulate matter and post-exercise breath pH. However both pre- and post-exercise breath pH were strikingly low in these athletes when compared to a control sample of 14 relatively sedentary healthy adults and to published values of breath pH in healthy subjects. Conclusion Although we did not observe an acute effect of air pollution exposure during exercise on breath pH, breath pH was surprisingly low in this sample of otherwise healthy long-distance runners. We speculate that repetitive vigorous exercise may induce airway acidification. PMID:18328105
Ha, Sung-min; Kwon, Oh-yun; Kim, Su-jung; Choung, Sung-dae
2014-02-01
A normal breathing pattern while performing the abdominal-hollowing (AH) maneuver or spinal-stabilization exercise is essential for the success of rehabilitation programs and exercises. In previous studies, subjects were given standardized instructions to control the influence of respiration during the AH maneuver. However, the effect of breathing pattern on abdominal-muscle thickness during the AH maneuver has not been investigated. To compare abdominal-muscle thickness in subjects performing the AH maneuver under normal and abnormal breathing-pattern conditions and to investigate the effect of breathing pattern on the preferential contraction ratio (PCR) of the transverse abdominis. Comparative, repeated-measures experimental study. University research laboratory. 16 healthy subjects (8 male, 8 female) from a university population. A real-time ultrasound scanner was used to measure abdominal-muscle thickness during normal and abnormal breathing patterns. A paired t test was used to assess the effect of breathing pattern on abdominal-muscle thickness and PCR. Muscle thickness in the transverse abdominis and internal oblique muscles was significantly greater under the normal breathing pattern than under the abnormal pattern (P < .05). The PCR of the transverse abdominis was significantly higher under the normal breathing pattern compared with the abnormal pattern (P < .05). The results indicate that a normal breathing pattern is essential for performance of an effective AH maneuver. Thus, clinicians should ensure that patients adopt a normal breathing pattern before performing the AH maneuver and monitor transverse abdominis activation during the maneuver.
Bin, Zhang; Ya-Zheng, Xu; Zhao-Hui, Deng; Bo, Chu; Li-Rong, Jiang; Vandenplas, Yvan
2015-03-01
This study aims to investigate Saccharomyces boulardii CNCM I-745 during Helicobacter pylori eradication in children. One hundred ninety-four H. pylori positive children were randomized in two groups. Therapy (omeprazole+clarithromycin+amoxicillin or omeprazole+clarithromycin+metronidazole in case of penicillin allergy) was given to both groups during two weeks. In the treatment group (n: 102) S. boulardii was added to the triple therapy, while the control group (n: 92) only received triple therapy. The incidence, onset, duration and severity of diarrhea and compliance to the eradication treatment were compared. A (13)C urea breath test was done 4 weeks after the end of eradication therapy in two groups of 21 patients aged 12 years and older to test the H. pylori eradication rate. In the treatment group, diarrhea occurred in 12 cases (11.76%), starting after 6.25±1.24 days, lasting 3.17±1.08 days, and compliance to eradication treatment was 100%. In the control group, diarrhea occurred in 26 cases (28.26%), starting after 4.05±1.11 days, lasting 4.02±0.87 days, and in six cases eradication treatment was stopped prematurely (p<0.05). The (13)C urea breath test showed successful H. pylori eradication in 71.4% of the patients in the treatment and in 61.9 % in the control group (not significant). S. boulardii has a beneficial effect on the prevention and treatment of diarrhea during H. pylori eradication in children. Although S. boulardii did only slightly increase H. pylori eradication rate, compliance to eradication treatment was improved.
Anekwe, David; de Marchie, Michel; Spahija, Jadranka
2017-06-01
Pressure support ventilation (PSV) may be used for exercise training in chronic obstructive pulmonary disease (COPD), but its acute effect on maximum exercise capacity is not fully known. The objective of this study was to evaluate the effect of 10 cm H 2 O PSV and a fixed PSV level titrated to patient comfort at rest on maximum exercise workload (WLmax), breathing pattern and metabolic parameters during a symptom-limited incremental bicycle test in individuals with COPD. Eleven individuals with COPD (forced expiratory volume in one second: 49 ± 16%; age: 64 ± 7 years) performed three exercise tests: without a ventilator, with 10 cm H 2 O of PSV and with a fixed level titrated to comfort at rest, using a SERVO-i ventilator. Tests were performed in randomized order and at least 48 hours apart. The WLmax, breathing pattern, metabolic parameters, and mouth pressure (Pmo) were compared using repeated measures analysis of variance. Mean PSV during titration was 8.2 ± 4.5 cm H 2 O. There was no difference in the WLmax achieved during the three tests. At rest, PSV increased the tidal volume, minute ventilation, and mean inspiratory flow with a lower end-tidal CO 2 ; this was not sustained at peak exercise. Pmo decreased progressively (decreased unloading) with PSV at workloads close to peak, suggesting the ventilator was unable to keep up with the increased ventilatory demand at high workloads. In conclusion, with a Servo-i ventilator, 10 cm H 2 O of PSV and a fixed level of PSV established by titration to comfort at rest, is ineffective for the purpose of achieving higher exercise workloads as the acute physiological effects may not be sustained at peak exercise.
van Nieuwenhoven, M A; Kovacs, E M; Brummer, R J; Westerterp-Plantenga, M S; Brouns, F
2001-02-01
There is no consensus about the effect of guar gum supplementation on gastrointestinal transit. It has been suggested that guar gum slows gastric emptying and intestinal transit, thus inducing an increased feeling of satiety. To investigate whether addition of guar gum to a semisolid meal affects gastrointestinal transit. Eight male subjects were randomly studied four times. They consumed a standard semisolid test meal containing either 0 g, 2.5 g, 3.5 g, or 4.5 g of guar gum. The test meals contained 1 mCi 99mTc-hepatate for scintigraphy and 5 g lactulose for the H2-breath test. Scintigraphic scanning was performed for at least two hours, and gastric half-emptying time (T1/2) was calculated. Breath samples were collected at 15 minute intervals and analyzed for H2-enrichment. The orocecal transit time (OCTT) was then determined. A parameter of intestinal transit (PIT) was obtained by subtracting the T1/2 from the OCTT. There were no significant differences (in minutes) between the different tests in both T1/2 (0 g, t = 88.2 +/- 11, 2.5 g, t = 83.3 +/- 11.9, 3.5 g, t = 83.3 +/- 13.6, 4.5 g, t = 72.4 +/- 7.2, p = 0.86) and PIT (0 g, t = 149.9 +/- 26.6, 2.5 g, t = 145.5 +/- 25.6, t = 3.5 g, t = 175.3 +/- 17.6, t = 4.5 g, t = 152.6 +/- 22.4, p = 0.52). Addition of guar gum to a semisolid meal up to a dosage of 4.5 g does not affect gastrointestinal transit. Other mechanisms than gastrointestinal motility are involved in a possible satiating effect of guar gum supplementation.
A fully integrated standalone portable cavity ringdown breath acetone analyzer.
Sun, Meixiu; Jiang, Chenyu; Gong, Zhiyong; Zhao, Xiaomeng; Chen, Zhuying; Wang, Zhennan; Kang, Meiling; Li, Yingxin; Wang, Chuji
2015-09-01
Breath analysis is a promising new technique for nonintrusive disease diagnosis and metabolic status monitoring. One challenging issue in using a breath biomarker for potential particular disease screening is to find a quantitative relationship between the concentration of the breath biomarker and clinical diagnostic parameters of the specific disease. In order to address this issue, we need a new instrument that is capable of conducting real-time, online breath analysis with high data throughput, so that a large scale of clinical test (more subjects) can be achieved in a short period of time. In this work, we report a fully integrated, standalone, portable analyzer based on the cavity ringdown spectroscopy technique for near-real time, online breath acetone measurements. The performance of the portable analyzer in measurements of breath acetone was interrogated and validated by using the certificated gas chromatography-mass spectrometry. The results show that this new analyzer is useful for reliable online (online introduction of a breath sample without pre-treatment) breath acetone analysis with high sensitivity (57 ppb) and high data throughput (one data per second). Subsequently, the validated breath analyzer was employed for acetone measurements in 119 human subjects under various situations. The instrument design, packaging, specifications, and future improvements were also described. From an optical ringdown cavity operated by the lab-set electronics reported previously to this fully integrated standalone new instrument, we have enabled a new scientific tool suited for large scales of breath acetone analysis and created an instrument platform that can even be adopted for study of other breath biomarkers by using different lasers and ringdown mirrors covering corresponding spectral fingerprints.
A fully integrated standalone portable cavity ringdown breath acetone analyzer
NASA Astrophysics Data System (ADS)
Sun, Meixiu; Jiang, Chenyu; Gong, Zhiyong; Zhao, Xiaomeng; Chen, Zhuying; Wang, Zhennan; Kang, Meiling; Li, Yingxin; Wang, Chuji
2015-09-01
Breath analysis is a promising new technique for nonintrusive disease diagnosis and metabolic status monitoring. One challenging issue in using a breath biomarker for potential particular disease screening is to find a quantitative relationship between the concentration of the breath biomarker and clinical diagnostic parameters of the specific disease. In order to address this issue, we need a new instrument that is capable of conducting real-time, online breath analysis with high data throughput, so that a large scale of clinical test (more subjects) can be achieved in a short period of time. In this work, we report a fully integrated, standalone, portable analyzer based on the cavity ringdown spectroscopy technique for near-real time, online breath acetone measurements. The performance of the portable analyzer in measurements of breath acetone was interrogated and validated by using the certificated gas chromatography-mass spectrometry. The results show that this new analyzer is useful for reliable online (online introduction of a breath sample without pre-treatment) breath acetone analysis with high sensitivity (57 ppb) and high data throughput (one data per second). Subsequently, the validated breath analyzer was employed for acetone measurements in 119 human subjects under various situations. The instrument design, packaging, specifications, and future improvements were also described. From an optical ringdown cavity operated by the lab-set electronics reported previously to this fully integrated standalone new instrument, we have enabled a new scientific tool suited for large scales of breath acetone analysis and created an instrument platform that can even be adopted for study of other breath biomarkers by using different lasers and ringdown mirrors covering corresponding spectral fingerprints.
Kim, Jean H; Wong, Alvin H; Goggins, William B; Lau, Joseph; Griffiths, Sian M
2013-07-01
To investigate the competing effects of increased anti-drink driving legislation and the recent elimination of excise taxes on wine and beer. Serial cross-sectional telephone surveys were conducted in 2006 (n = 9860) and 2011 (n = 4800). Hong Kong, China. Chinese adults (≥18 years of age). Respondents were asked about their drinking patterns, past-year experience of driving within 2 hours of drinking, drinking-related attitudes and reported deterrents to drink driving. Following the legislative changes, the age-standardized past-year prevalence of drink driving decreased significantly from 5.2 to 2.8% (P < 0.001) among all males, from 9.0 to 4.4% (P < 0.001) among male past-year drinkers and from 13.7 to 8.5% (P < 0.01) among male weekly drinkers. The past-year prevalence of drink driving in 2011 among all females (0.08%), female past-year drinkers (1.6%), male binge drinkers (12.5%), female weekly drinkers (4.7%) and female binge drinkers (7.9%) were not significantly different from 2006. Drink driving was associated independently with business sector employment [odds ratio (OR) = 2.47], past-month binge drinking (OR = 6.08) and beliefs in the benefits to one's wellbeing of drinking (OR = 2.62) among males and past-month binge drinking (OR = 5.57), belief in the social benefits of drinking (OR = 5.66) and being unmarried (OR = 3.00) in females (P < 0.05). The most commonly reported drink driving deterrents were concerns about random breath tests (93.8%) and the potential legal consequences of conviction (93.6-96.5%). Despite greater alcohol consumption in Hong Kong, the current anti-drink driving strategy appears to reduce drink driving in males and prevent increased levels among females. Binge drinkers, however, remain a high-risk group that should be monitored continually. © 2013 The Authors, Addiction © 2013 Society for the Study of Addiction.
The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea.
Javaheri, Shahrokh; Goetting, Mark G; Khayat, Rami; Wylie, Paul E; Goodwin, James L; Parthasarathy, Sairam
2011-12-01
This study was conducted to evaluate the therapeutic performance of a new auto Servo Ventilation device (Philips Respironics autoSV Advanced) for the treatment of complex central sleep apnea (CompSA). The features of autoSV Advanced include an automatic expiratory pressure (EPAP) adjustment, an advanced algorithm for distinguishing open versus obstructed airway apnea, a modified auto backup rate which is proportional to subject's baseline breathing rate, and a variable inspiratory support. Our primary aim was to compare the performance of the advanced servo-ventilator (BiPAP autoSV Advanced) with conventional servo-ventilator (BiPAP autoSV) in treating central sleep apnea (CSA). A prospective, multicenter, randomized, controlled trial. Five sleep laboratories in the United States. Thirty-seven participants were included. All subjects had full night polysomnography (PSG) followed by a second night continuous positive airway pressure (CPAP) titration. All had a central apnea index ≥ 5 per hour of sleep on CPAP. Subjects were randomly assigned to 2 full-night PSGs while treated with either the previously marketed autoSV, or the new autoSV Advanced device. The 2 randomized sleep studies were blindly scored centrally. Across the 4 nights (PSG, CPAP, autoSV, and autoSV Advanced), the mean ± 1 SD apnea hypopnea indices were 53 ± 23, 35 ± 20, 10 ± 10, and 6 ± 6, respectively; indices for CSA were 16 ± 19, 19 ± 18, 3 ± 4, and 0.6 ± 1. AutoSV Advanced was more effective than other modes in correcting sleep related breathing disorders. BiPAP autoSV Advanced was more effective than conventional BiPAP autoSV in the treatment of sleep disordered breathing in patients with CSA.
Exhaled breath temperature in children: reproducibility and influencing factors.
Vermeulen, S; Barreto, M; La Penna, F; Prete, A; Martella, S; Biagiarelli, F; Villa, M P
2014-09-01
This study will investigate the reproducibility and influencing factors of exhaled breath temperature measured with the tidal breathing technique in asthmatic patients and healthy children. Exhaled breath temperature, fractional exhaled nitric oxide, and spirometry were assessed in 124 children (63 healthy and 61 asthmatic), aged 11.2 ± 2.5 year, M/F 73/51. A modified version of the American Thoracic Society questionnaire on the child's present and past respiratory history was obtained from parents. Parents were also asked to provide detailed information on their child's medication use during the previous 4 weeks. Ear temperature, ambient temperature, and relative-ambient humidity were also recorded. Exhaled breath temperature measurements were highly reproducible; the second measurement was higher than the first measurement, consistent with a test-retest situation. In 13 subjects, between-session within-day reproducibility of exhaled breath temperature was still high. Exhaled breath temperature increased with age and relative-ambient humidity. Exhaled breath temperature was comparable in healthy and asthmatic children; when adjusted for potential confounders (i.e. ambient conditions and subject characteristics), thermal values of asthmatic patients exceeded those of the healthy children by 1.1 °C. Normalized exhaled breath temperature, by subtracting ambient temperature, was lower in asthmatic patients treated with inhaled corticosteroids than in those who were corticosteroid-naive. Measurements of exhaled breath temperature are highly reproducible, yet influenced by several factors. Corrected values, i.e. normalized exhaled breath temperature, could help us to assess the effect of therapy with inhaled corticosteroids. More studies are needed to improve the usefulness of the exhaled breath temperature measured with the tidal breathing technique in children.
Impact of orocecal transit time on patient´s perception of lactose intolerance.
Casellas, Francesc; Aparici, Anna; Casaus, Maite; Rodríguez, Purificación; Malagelada, Juan R
2013-01-01
symptoms attributed to the lactose intolerance are an important public health issue because of their prevalence and social relevance. Also because they may cause undue rejection of dairy products consume with potential health consequences. Transit time is a putative factor implied in the severity of symptoms associated with lactose. to elucidate the relation between orocecal transit time (OCTT) and lactose intolerance symptoms. observational study in patients referred to a lactose hydrogen breath test who showed an increase in breath H2 excretion higher than 25 ppm. OCTT was measured with the breath test and symptoms of lactose tolerance with a validated scale. Symptoms were measured twice: before receiving the lactose, inquiring about self perceived symptoms when patients consumed dairy products at home ("home symptoms"), and again after completing the lactose breath test ("test symptoms"). 161 patients were included. There was no correlation between OCTT and home symptoms (r = -0.1). When OCTT was faster than 60 minutes, intensity of "test symptoms" was similar to "home symptoms". However, in patients with normal or slow OCTT, the "home symptoms" were more intense than the "test symptoms" (p < 0.05). At home, symptoms were independent of OCTT but with the lactose test load the symptoms were proportionately more intense with faster OCTT. in lactose maldigesters, selfreported symptoms of lactose intolerance are more pronounced at home than after a high lactose challenge. Intolerance symptoms that patients attributed to lactose consume at home are due to factors other than fast OCTT.
Glinn, Michele; Adatsi, Felix; Curtis, Perry
2011-11-01
The State of Michigan uses the Datamaster as an evidential breath testing device. The newest version, the DMT, will replace current instruments in the field as they are retired from service. The Michigan State Police conducted comparison studies to test the analytical properties of the new instrument and to evaluate its response to conditions commonly cited in court defenses. The effects of mouth alcohol, objects in the mouth, and radiofrequency interference on paired samples from drinking subjects were assessed on the DMT. The effects of sample duration and chemical interferents were assessed on both instruments, using drinking subjects and wet-bath simulators, respectively. Our testing shows that Datamaster and DMT results are essentially identical; the DMT gave accurate readings as compared with measurements made using simulators containing standard ethanol solutions and that the DMT did not give falsely elevated breath alcohol results from any of the influences tested. © 2011 American Academy of Forensic Sciences.
TU-EF-304-03: 4D Monte Carlo Robustness Test for Proton Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Souris, K; Sterpin, E; Lee, J
Purpose: Breathing motion and approximate dose calculation engines may increase proton range uncertainties. We address these two issues using a comprehensive 4D robustness evaluation tool based on an efficient Monte Carlo (MC) engine, which can simulate breathing with no significant increase in computation time. Methods: To assess the robustness of the treatment plan, multiple scenarios of uncertainties are simulated, taking into account the systematic and random setup errors, range uncertainties, and organ motion. Our fast MC dose engine, called MCsquare, implements optimized models on a massively-parallel computation architecture and allows us to accurately simulate a scenario in less than onemore » minute. The deviations of the uncertainty scenarios are then reported on a DVH-band and compared to the nominal plan.The robustness evaluation tool is illustrated in a lung case by comparing three 60Gy treatment plans. First, a plan is optimized on a PTV obtained by extending the CTV with an 8mm margin, in order to take into account systematic geometrical uncertainties, like in our current practice in radiotherapy. No specific strategy is employed to correct for tumor and organ motions. The second plan involves a PTV generated from the ITV, which encompasses the tumor volume in all breathing phases. The last plan results from robust optimization performed on the ITV, with robustness parameters of 3% for tissue density and 8 mm for positioning errors. Results: The robustness test revealed that the first two plans could not properly cover the target in the presence of uncertainties. CTV-coverage (D95) in the three plans ranged respectively between 39.4–55.5Gy, 50.2–57.5Gy, and 55.1–58.6Gy. Conclusion: A realistic robustness verification tool based on a fast MC dose engine has been developed. This test is essential to assess the quality of proton therapy plan and very useful to study various planning strategies for mobile tumors. This work is partly funded by IBA (Louvain-la-Neuve, Belgium)« less
Activation of respiratory muscles during weaning from mechanical ventilation.
Walterspacher, Stephan; Gückler, Julia; Pietsch, Fabian; Walker, David Johannes; Kabitz, Hans-Joachim; Dreher, Michael
2017-04-01
Respiratory muscle dysfunction is a key component of weaning failure. Balancing respiratory muscle loading and unloading by applying different ventilation modes along with spontaneous breathing episodes are established weaning strategies. However, the effects of body positioning on the respiratory muscles during weaning remains unclear. This study aimed at assessing respiratory drive by surface electromyography (EMG) of the diaphragm (EMG dia ) and parasternal muscles (EMG para ) in tracheotomized patients during prolonged weaning in 3 randomized body positions-supine, 30° semirecumbent, and 80° sitting-during mechanical ventilation and spontaneous breathing. Nine patients were included for analysis. Cardiorespiratory parameters (heart rate, blood pressure, arterial oxygen saturation, dyspnea) did not change under each condition (all P>.05). EMG para and EMG dia did not change under mechanical ventilation (both P>.05). EMG dia changed under spontaneous breathing from supine to sitting (0.45±0.26 vs 0.32±0.19; P=.012) and between semirecumbent to sitting (0.41±0.23 vs 0.32±0.19; P=.039), whereas EMG para did not change. This is the first study to show that body positioning influences respiratory drive to the diaphragm in tracheotomized patients with prolonged weaning from mechanical ventilation during unassisted breathing. Sitting position reduces respiratory drive compared with semirecumbent and supine positioning and might therefore be favored during spontaneous breathing trials. Copyright © 2016 Elsevier Inc. All rights reserved.
Laboratory evaluation of two passive alcohol sensor devices
DOT National Transportation Integrated Search
1988-12-01
Passive alcohol sensing devices are designed to detect the presence of alcohol in a person's normally-expelled breath; they are "passive" in that one is not required to blow into a mouthpiece as with conventional breath test devices. The National Hig...
Breath biomarkers in toxicology.
Pleil, Joachim D
2016-11-01
Exhaled breath has joined blood and urine as a valuable resource for sampling and analyzing biomarkers in human media for assessing exposure, uptake metabolism, and elimination of toxic chemicals. This article focuses current use of exhaled gas, aerosols, and vapor in human breath, the methods for collection, and ultimately the use of the resulting data. Some advantages of breath are the noninvasive and self-administered nature of collection, the essentially inexhaustible supply, and that breath sampling does not produce potentially infectious waste such as needles, wipes, bandages, and glassware. In contrast to blood and urine, breath samples can be collected on demand in rapid succession and so allow toxicokinetic observations of uptake and elimination in any time frame. Furthermore, new technologies now allow capturing condensed breath vapor directly, or just the aerosol fraction alone, to gain access to inorganic species, lung pH, proteins and protein fragments, cellular DNA, and whole microorganisms from the pulmonary microbiome. Future applications are discussed, especially the use of isotopically labeled probes, non-targeted (discovery) analysis, cellular level toxicity testing, and ultimately assessing "crowd breath" of groups of people and the relation to dose of airborne and other environmental chemicals at the population level.
Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, Marco; Tricoli, Antonio; Gass, Samuel; Schmid, Alex; Amann, Anton; Pratsinis, Sotiris E.
2013-01-01
Breath analysis has the potential for early stage detection and monitoring of illnesses to drastically reduce the corresponding medical diagnostic costs and improve the quality of life of patients suffering from chronic illnesses. In particular, the detection of acetone in the human breath is promising for non-invasive diagnosis and painless monitoring of diabetes (no finger pricking). Here, a portable acetone sensor consisting of flame-deposited and in situ annealed, Si-doped epsilon-WO3 nanostructured films was developed. The chamber volume was miniaturized while reaction-limited and transport-limited gas flow rates were identified and sensing temperatures were optimized resulting in a low detection limit of acetone (~20 ppb) with short response (10–15 s) and recovery times (35–70 s). Furthermore, the sensor signal (response) was robust against variations of the exhaled breath flow rate facilitating application of these sensors at realistic relative humidities (80–90%) as in the human breath. The acetone content in the breath of test persons was monitored continuously and compared to that of state-of-the-art proton transfer reaction mass spectrometry (PTR-MS). Such portable devices can accurately track breath acetone concentration to become an alternative to more elaborate breath analysis techniques. PMID:22790702
Maa, Suh-Hwa; Wang, Chiu-Hua; Hsu, Kuang-Hung; Lin, Horng-Chyuan; Yee, Brian; MacDonald, Karen
2013-01-01
Background. Acupressure has been shown to improve respiratory parameters. We investigated the effects of acupressure on weaning indices in stable coma patients receiving mechanical ventilation. Methods. Patients were randomly allocated to one of three treatments: standard care with adjunctive acupressure on one (n = 32) or two days (n = 31) and standard care (n = 31). Acupressure in the form of 10 minutes of bilateral stimulation at five acupoints was administered per treatment session. Weaning indices were collected on two days before, right after, and at 0.5 hrs, 1 hr, 1.5 hrs, 2 hrs, 2.5 hrs, 3 hrs, 3.5 hrs, and 4 hrs after the start of treatment. Results. There were statistically significant improvements in tidal volumes and index of rapid shallow breathing in the one-day and two-day adjunctive acupressure study arms compared to the standard care arm immediately after acupressure and persisting until 0.5, 1 hr, and 2 hrs after adjustment for covariates. Conclusions. In the stable ventilated coma patient, adjunctive acupressure contributes to improvements in tidal volumes and the index of rapid shallow breathing, the two indices most critical for weaning patients from mechanical ventilation. These effects tend to be immediate and likely to be sustained for 1 to 2 hours. PMID:23710234
Diagnostic accuracy of the 14C-urea breath test in Helicobacter pylori infections: a meta-analysis.
Zhou, Qiaohui; Li, Ling; Ai, Yaowei; Pan, Zhihong; Guo, Mingwen; Han, Jingbo
2017-01-01
To summarize and appraise the available literature regarding the use of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspepsia and to calculate pooled diagnostic accuracy measures. We systematically searched the PubMed, EMBASE, Cochrane Library, Chinese Journals Full-text (CNKI) and CBMDisc databases to identify published data regarding the sensitivity, specificity, and other measures of diagnostic accuracy of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspeptic symptoms. Risk of bias was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies)-2 tool. Statistical analyses were performed using Meta-Disc 1.4 software and STATA. Eighteen studies met the inclusion criteria. Pooled results indicated that the 14 C-urea breath test showed a diagnostic sensitivity of 0.96 (95% CI 0.95 to 0.96) and specificity of 0.93 (95% CI 0.91 to 0.94). The positive like ratio (PLR) was 12.27 (95% CI 8.17 to 18.44), the negative like ratio (NLR) was 0.05 (95% CI 0.04 to 0.07), and the area under the curve was 0.985. The DOR was 294.95 (95% CI 178.37 to 487.70). The 14 C-urea breath test showed sufficient sensitivity and specificity for diagnosing Helicobacter pylori infection, but unexplained heterogeneity after meta-regression and several subgroup analyses remained. The UBT has high accuracy for diagnosing H. pylori infections in adult patients with dyspepsia. However, the reliability of these diagnostic meta-analytic estimates is limited by significant heterogeneity due to unknown factors.
Ho, S C; Chiang, L L; Cheng, H F; Lin, H C; Sheng, D F; Kuo, H P; Lin, H C
2000-02-01
Chronic obstructive airway diseases (COAD), characterized by mucus hypersecretion, lead to exercise intolerance. Incentive spirometry has been used to prevent postoperative pulmonary atelectasis. To compare the efficacy of two incentive spirometers, Coach (volume-oriented) and Triflo (flow-oriented), in the work of breathing in COAD patients, 22 patients were randomized in this study: 12 patients (Triflo-II group) initially used Triflo-II for 10 minutes and then Coach for the same period. In contrast, the Coach group, including 10 patients, started with Coach followed by Triflo-II. After receiving incentive spirometry, lung expansion and work of breathing were assessed. Patients in the Coach group significantly increased chest wall expansion (p = 0.041), as compared with patients using Triflo-II. Similarly, there was also a significantly increased abdominal wall expansion in the Coach group (p = 0.0056), compared with that in the Triflo-II group. The need of accessory muscle assistance for breathing in the Coach group was significantly less than in the Triflo-II group (p = 0.047). It was easier for patients in the Coach group to start a breath (p = 0.0058) than for those in the Triflo-II group. For the entire group, 17 patients (77.3%) preferred Coach to assist their breathing, and only 4 patients (18.2%) favored Triflo-II. COAD patients achieved a larger expansion of the chest and abdomen with a Coach device. Our data provide a good rationale for an outcome study on the use of incentive spirometer in COAD patients.
Thaysen, E H; Orholm, M; Arnfred, T; Carl, J; Rødbro, P
1982-01-01
In eight patients without gastrointestinal complaints and 30 patients with various gastrointestinal disorders ileal bile acid conservation was assessed by oral administration of 75Se 23-selena-25-homocholic acid (SeHCAT) followed by abdominal gamma counting (SeHCAT-test). The results of the test correlated fairly well with the clinical features and with the [1-14C]-cholylglycine breath test including faecal 14C measurements (breath test). Of the two bile acid absorption tests the new is perhaps the more sensitive and is the one most easily performed. PMID:7117906
Li, Changjun; Chang, Qinghua; Zhang, Jia; Chai, Wenshu
2018-05-01
This study is to investigate the effects of slow breathing on heart rate variability (HRV) and arterial baroreflex sensitivity in essential hypertension.We studied 60 patients with essential hypertension and 60 healthy controls. All subjects underwent controlled breathing at 8 and 16 breaths per minute. Electrocardiogram, respiratory, and blood pressure signals were recorded simultaneously. We studied effects of slow breathing on heart rate, blood pressure and respiratory peak, high-frequency (HF) power, low-frequency (LF) power, and LF/HF ratio of HRV with traditional and corrected spectral analysis. Besides, we tested whether slow breathing was capable of modifying baroreflex sensitivity in hypertensive subjects.Slow breathing, compared with 16 breaths per minute, decreased the heart rate and blood pressure (all P < .05), and shifted respiratory peak toward left (P < .05). Compared to 16 breaths/minute, traditional spectral analysis showed increased LF power and LF/HF ratio, decreased HF power of HRV at 8 breaths per minute (P < .05). As breathing rate decreased, corrected spectral analysis showed increased HF power, decreased LF power, LF/HF ratio of HRV (P < .05). Compared to controls, resting baroreflex sensitivity decreased in hypertensive subjects. Slow breathing increased baroreflex sensitivity in hypertensive subjects (from 59.48 ± 6.39 to 78.93 ± 5.04 ms/mm Hg, P < .05) and controls (from 88.49 ± 6.01 to 112.91 ± 7.29 ms/mm Hg, P < .05).Slow breathing can increase HF power and decrease LF power and LF/HF ratio in essential hypertension. Besides, slow breathing increased baroreflex sensitivity in hypertensive subjects. These demonstrate slow breathing is indeed capable of shifting sympatho-vagal balance toward vagal activities and increasing baroreflex sensitivity, suggesting a safe, therapeutic approach for essential hypertension.
Chen, Steve; Kim, Woosong; Henning, Susanne M; Carpenter, Catherine L; Li, Zhaoping
2010-03-23
Human exercise capacity declines with advancing age. These changes often result in loss of physical fitness and more rapid senescence. Nitric oxide (NO) has been implicated in improvement of exercise capacity through vascular smooth muscle relaxation in both coronary and skeletal muscle arteries, as well as via independent mechanisms. Antioxidants may prevent nitric oxide inactivation by oxygen free radicals. The purpose of this study was to investigate the effects of an L-arginine and antioxidant supplement on exercise performance in elderly male cyclists. This was a two-arm prospectively randomized double-blinded and placebo-controlled trial. Sixteen male cyclists were randomized to receive either a proprietary supplement (Niteworks(R), Herbalife International Inc., Century City, CA) or a placebo powder. Exercise parameters were assessed by maximal incremental exercise testing performed on a stationary cycle ergometer using breath-by-breath analysis at baseline, week one and week three. There was no difference between baseline exercise parameters. In the supplemented group, anaerobic threshold increased by 16.7% (2.38 +/- 0.18 L/min, p < 0.01) at week 1, and the effect was sustained by week 3 with a 14.2% (2.33 +/- 0.44 L/min, p < 0.01). In the control group, there was no change in anaerobic threshold at weeks 1 and 3 compared to baseline (1.88 +/- 0.20 L/min at week 1, and 1.86 +/- 0.21 L/min at week 3). The anaerobic threshold for the supplement groups was significantly higher than that of placebo group at week 1 and week 3. There were no significant changes noted in VO2 max between control and intervention groups at either week 1 or week 3 by comparison to baseline. An arginine and antioxidant-containing supplement increased the anaerobic threshold at both week one and week three in elderly cyclists. No effect on VO2 max was observed. This study indicated a potential role of L-arginine and antioxidant supplementation in improving exercise performance in elderly.
Proportional assist ventilation system based on proportional solenoid valve control.
Lua, A C; Shi, K C; Chua, L P
2001-07-01
A new proportional assist ventilation (PAV) method using a proportional solenoid valve (PSV) to control air supply to patients suffering from respiratory disabilities, was studied. The outlet flow and pressure from the proportional solenoid valve at various air supply pressures were tested and proven to be suitable for pressure and flow control in a PAV system. In vitro tests using a breathing simulator, which has been proven to possess the general characteristics of human respiratory system in spontaneous breathing tests, were conducted and the results demonstrated the viability of this PAV system in normalizing the breathing patterns of patients with abnormally high resistances and elastances as well as neuromuscular weaknesses. With a back-up safety mechanism incorporated in the control program, pressure "run-away" can be effectively prevented and safe operation of the system can be guaranteed.
Gothe, Neha P; Kramer, Arthur F; McAuley, Edward
2017-01-01
Age-related cognitive decline is well documented across various aspects of cognitive function, including attention and processing speed, and lifestyle behaviors such as physical activity play an important role in preventing cognitive decline and maintaining or even improving cognitive function. The purpose of this study was to evaluate the effects of an 8-week Hatha yoga intervention on attention and processing speed among older adults. Participants (n = 118; mean age, 62 ± 5.59) were randomly assigned to an 8-week Hatha yoga group or a stretching control group and completed cognitive assessments-Attention Network Task, Trail Making Test parts A and B, and Pattern Comparison Test-at baseline and after the 8-week intervention. Analyses of covariance revealed significantly faster reaction times for the yoga group on the Attention Network Task's neutral, congruent, and incongruent conditions (p ≤ 0.04). The yoga intervention also improved participants' visuospatial and perceptual processing on the Trail Making Test part B (p = 0.002) and pattern comparison (p < 0.001) tests. These results suggest that yoga practice that includes postures, breathing, and meditative exercises lead to improved attentional and information processing abilities. Although the underlying mechanisms remain largely speculative, more systematic trials are needed to explore the extent of cognitive benefits and their neurobiological mechanisms.
Chumpitazi, Bruno P; Weidler, Erica M; Shulman, Robert J
2017-04-01
In adults with irritable bowel syndrome (IBS), bacterial gas production (colonic fermentation) is related to both symptom generation and intestinal transit. Whether gas production affects symptom generation, psychosocial distress, or intestinal transit in childhood IBS is unknown. Children (ages 7-17 years) with pediatric Rome III IBS completed validated psychosocial questionnaires and a 2-week daily diary capturing pain and stooling characteristics. Stool form determined IBS subtype. Subjects then completed a 3-hour lactulose breath test for measurement of total breath hydrogen and methane production. Carmine red was used to determine whole intestinal transit time. A total of 87 children (mean age 13 ± 2.6 [standard deviation] years) were enrolled, of whom 50 (57.5%) were girls. All children produced hydrogen and 51 (58.6%) produced methane. Hydrogen and methane production did not correlate with either abdominal pain frequency/severity or psychosocial distress. Hydrogen and methane production did not differ significantly by IBS subtype. Methane production correlated positively with whole intestinal transit time (r = 0.31, P < 0.005) and inversely with bowel movement frequency (r = -0.245, P < 0.05). Methane production (threshold 3 ppm) as a marker for identifying IBS-C had a sensitivity of 60% and specificity of 42.9%. Lactulose breath test total methane production may serve as a biomarker of whole intestinal transit time and bowel movement frequency in children with IBS. In children with IBS, lactulose breath test hydrogen and methane production did not, however, correlate with abdominal pain, IBS subtype, or psychosocial distress.
The accuracy of evidential breath testers at low BACs
DOT National Transportation Integrated Search
1989-05-01
This Technical Note reports on the low blood alcohol concentration (BAC) laboratory testing of seven evidential breath testers widely used by law enforcement. The findings indicated that these devices are just as accurate at low BACs in the 0.020-0.0...
Use of warrants for breath test refusal : case studies
DOT National Transportation Integrated Search
2007-10-01
This study investigated the use of warrants to obtain blood samples from drivers arrested for alcohol-impaired driving and who refuse to provide breath samples when requested to do so by law enforcement officers. Case studies were conducted in four S...
Evaluation of the Sierra, hanging, quick-don, crew, pressure-breathing, oxygen mask.
DOT National Transportation Integrated Search
1966-06-01
A new design, hanging, quick-don crew pressure breathing oxygen mask applicable to jet-transport operations was tested and evaluated in three phases, consisting of (1) exposing five masked subjects to a stepwise altitude-chamber flight profile with a...
An analysis of potential breathing devices intended for use by aircraft passengers.
DOT National Transportation Integrated Search
1983-05-01
This report presents the results of tests performed to examine concepts for the development of a passenger-type protective breathing device which would provide protection from toxic smoke/fumes produced during an in- flight fire and afford some prote...
Lactose intolerance in Thai adults.
Densupsoontorn, Narumon; Jirapinyo, Pipop; Thamonsiri, Nuchnoi; Chantaratin, Sasitorn; Wongarn, Renu
2004-12-01
Lactose intolerance is common in Thai adults who ingest cow's milk but its incidence has not been clearly defined The authors evaluated 45 volunteers (15 males, 35 females), aged 21-31 yrs old, who drank one 240-ml box of milk daily. A Lactose tolerance test was performed using a breath-hydrogen test (BHT) after oral intake of 25 g of lactose dissolved in 250 ml of water The presence of gastrointestinal symptoms of lactose intolerance, flatulence, abdominal pain and diarrhea, were recorded Twenty-one subjects (47%) were categorized as lactose malabsorbers and intolerant, two subjects (4%) were malabsorbers but tolerant, and 22 of 45 (49%) were absorbers and tolerant. The incidence of lactose malabsorption was, thus, 51%; symptoms of intolerance were found in 21 of the 23 malabsorbers, making the incidence of lactose intolerance 47%. In the lactose malabsorbant and intolerant group, the more breath-hydrogen (H) the more symptoms observed All subjects who had a negative breath-H2 test had no symptoms. The breath-H2 test should be used as a standard method to evaluate lactose absorption and lactose tolerance. The incidence of lactose intolerance has decreased from the past and the symptoms are not so severe that the people limit the consumption of milk since it is a major source of food containing good quality of protein and calcium.
Carbon-14 urea breath test: does it work in patients with partial gastric resection?
Dede, Fuat; Civen, Hüseyin; Dane, Faysal; Aliustaoglu, Mehmet; Turhal, Serdar; Turoglu, Halil Turgut; Inanir, Sabahat
2015-11-01
The diagnostic value of Carbon-14 urea breath test (C-14 UBT) in the detection of Helicobacter pylori (H. pylori) infection in non-operated patients has been proved. However, the efficacy of C-14 UBT in patients with partial gastric resection (PGR) has not been evaluated yet. Herein, the results of the C-14 UBT and H. pylori stool antigen test (HpSAT) in this patient group were compared with the endoscopic findings. Multi-breath samples C-14 UBT and HpSAT were performed in all patients on the same day. Histology was used as a gold standard for testing C-14 UBT and HpSAT diagnostic efficacies. 30 patients (mean age: 54.6 ± 11 year) with PGR were included. The sensitivity and specificity of standard C-14 UBT were 29 and 100 %, respectively. When breath samples were collected at 20th min, and >35 CPM was selected as radioactivity threshold, the sensitivity raised to 86 % without any loss of specificity. The specificity and sensitivity of the HpSAT were 71 and 96 %, respectively. The sensitivity of the standard C-14 UBT was very poor for patients with PGR, and results of HpSAT were superior in this population. Certain modifications are needed if C-14 UBT is to be used in PGR patients.
Gonella, Silvia; Berchialla, Paola; Bruno, Benedetto; Di Giulio, Paola
2014-09-01
Nausea and vomiting (NV) related to DMSO affect patients undergoing auto-SCT despite antiemetic measures. Orange flavoring may reduce gastrointestinal symptoms. A multicenter, randomized, three-arm, open-label trial in four Italian large bone marrow transplant centers was conducted to assess the effectiveness of orange aroma in preventing NV related to DMSO. Patients were randomized to orange ice lollies, non-citrus ice lollies, and routine treatment (deep breaths) during reinfusion. Data on NV were collected up to 5 days after infusion; 69/98 patients were randomized: 23 to orange, 21 to non-citrus ice lollies, and 25 to routine treatment. Although 48 h after transplantation no differences were observed in controlled nausea (Numerical Rating Scale (NRS) 0-100, ≤25) or vomiting, significantly fewer patients had no episodes of vomiting, no antiemetic rescue therapy, and no nausea (NRS <5) in the deep breath vs lollies groups (P = 0.017). The intensity of nausea over time differed significantly between ice lollies vs routine care (P = 0.001) groups, but not between the orange and non-citrus groups (P = 0.428). The vasoconstrictive action of ice may prevent NV related to DMSO in the acute phase and reduce the need for rescue antiemetic therapy. Ice lollies offer a simple, noninvasive, and economic means for relieving nausea and vomiting related to this preservative.
Burnheim, K; Hughes, K J; Evans, D L; Raidal, S L
2016-11-28
Respiratory problems are common in horses, and are often diagnosed as a cause of poor athletic performance. Reliable, accurate and sensitive spirometric tests of airway function in resting horses would assist with the diagnosis of limitations to breathing and facilitate investigations of the effects of various treatments on breathing capacity. The evaluation of respiratory function in horses is challenging and suitable procedures are not widely available to equine practitioners. The determination of relative flow or flow-time measures is used in paediatric patients where compliance may limit conventional pulmonary function techniques. The aim of the current study was to characterise absolute and relative indices of respiratory function in healthy horses during eupnoea (tidal breathing) and carbon dioxide (CO 2 )-induced hyperpnoea (rebreathing) using a modified mask pneumotrachographic technique well suited to equine practice, and to evaluate the reliability of this technique over three consecutive days. Coefficients of variation, intra-class correlations, mean differences and 95% confidence intervals across all days of testing were established for each parameter. The technique provided absolute measures of respiratory function (respiratory rate, tidal volume, peak inspiratory and expiratory flows, time to peak flow) consistent with previous studies and there was no significant effect of day on any measure of respiratory function. Variability of measurements was decreased during hyperpnea caused by rebreathing CO 2 , but a number of relative flow-time variables demonstrated good agreement during eupnoeic respiration. The technique was well tolerated by horses and study findings suggest the technique is suitable for evaluation of respiratory function in horses. The use of relative flow-time variables provided reproducible (consistent) results, suggesting the technique may be of use for repeated measures studies in horses during tidal breathing or rebreathing.
High-pitched breath sounds indicate airflow limitation in asymptomatic asthmatic children.
Habukawa, Chizu; Nagasaka, Yukio; Murakami, Katsumi; Takemura, Tsukasa
2009-04-01
Asthmatic children may have airway dysfunction even when asymptomatic, indicating that their long-term treatment is less than optimal. Although airway dysfunction can be identified on lung function testing, performing these tests can be difficult in infants. We studied whether breath sounds reflect subtle airway dysfunction in asthmatic children. The highest frequency of inspiratory breaths sounds (HFI) and the highest frequency of expiratory breath sounds (HFE) were measured in 131 asthmatic children while asymptomatic and with no wheezes for more than 2 weeks. No child was being treated with inhaled corticosteroids (ICS). Breath sounds were recorded and analysed by sound spectrography and compared with spirometric parameters. After initial evaluation, cases with more than step 2 (mild persistent) asthma were treated using inhaled fluticasone (100-200 microg/day) for 1 month, and then breath sound analysis and pulmonary function testing were repeated. On initial evaluation, HFI correlated with the percentage of predicted FEF(50) (%FEF(50)), (r = -0.45, P < 0.001), the percentage of predicted FEF(75) (%FEF(75)) (r = -0.456, P < 0.001), and FEV(1) as a percentage of FVC (FEV(1)/FVC (%)) (r = -0.32, P < 0.001). HFI did not correlate with the percentage of predicted PEF (%PEF). The 69 children with lower than normal %FEF(50) were then treated with ICS. The %FEF(50) and %FEF(75) improved after ICS treatment, and increases in %FEF(50) (P < 0.005) correlated with decreases in HFI (P < 0.001). Higher HFI in asymptomatic asthmatic children may indicate small airway obstruction. Additional ICS treatment may improve the pulmonary function indices representing small airway function with simultaneous HFI decreases in such patients.
Nakanishi, Keisuke; Takahira, Naonobu; Sakamoto, Miki; Yamaoka-Tojo, Minako; Katagiri, Masato; Kitagawa, Jun
2018-02-01
Patients with plaster cast immobilization of the lower limb have an estimated symptomatic venous thromboembolism rate of 5.5%. However, there is currently no practical physical prophylaxis for deep-vein thrombosis (DVT). The objective of this study was to examine the effects of forced deep breathing on peak blood velocity in the superficial femoral vein (PBVFV), which is a surrogate measure of the efficacy of thromboprophylaxis against DVT, in patients with plaster cast immobilization of the lower limb. Nine young males and 18 elderly males were recruited. We immobilized the right lower limb of each subject with a plaster splint and measured PBVFV during forced deep breathing in supine and sitting positions. In all subjects, PBVFV during forced deep breathing in both positions was significantly higher than at rest. There was no significant difference in the PBVFV change ratio for three breathing rates in the sitting position for the young subjects (15breaths/min: 415%, 5breaths/min: 475%, 3breaths/min: 483%), whereas that for the elderly subjects at 3breaths/min (449%) was significantly higher than that at 15breaths/min (284%). Forced deep breathing significantly increased PBVFV in patients with plaster cast immobilization of the lower limb in both supine and sitting positions. Testing the efficacy and adherence in clinical contexts, and following up with the incidence rate of DVT in future studies, is necessary for the development of a new physical prophylaxis for DVT. Copyright © 2017 Elsevier Ltd. All rights reserved.
Breathing pattern and head posture: changes in craniocervical angles.
Sabatucci, A; Raffaeli, F; Mastrovincenzo, M; Luchetta, A; Giannone, A; Ciavarella, D
2015-04-01
The aim of this study was to observe the influence of oral breathing on head posture and to establish possible postural changes observing the variation of craniocervical angles NSL/OPT and NSL/CVT between oral breathing subjects and physiological breathing subjects. A cross-sectional study was conducted. The sample included 115 subject, 56 boys and 59 girls, 5-22-year-old. Among these, 80 were classified as oral breathers and 35 as physiological breathers. The diagnosis of oral breathing was carried out thanks to characteristic signs and symptoms evaluated on clinical examination, the analysis of characteristic X-ray images, ENT examination with active anterior rhinomanometric (AAR) test. The structural and postural analysis was carried out, calculating the craniofacial angles NSL/OPT and NSL/CVT. Both NSL/OPT and NSL/CVT appear to be significantly greater to those observed in physiological breathing patients. This means that patients who tend to breathe through the mouth rather than exclusively through the nose show a reduction of cervical lordosis and a proinclination of the head. Our study confirms that the oral breathing modifies head position. The significant increase of the craniocervical angles NSL/OPT and NSL/CVT in patients with this altered breathing pattern suggests an elevation of the head and a greater extension of the head compared with the cervical spine. So, to correct the breathing pattern early, either during childhood or during adolescence, can lead to a progressive normalization of craniofacial morphology and head posture.
Itoh, Toshio; Miwa, Toshio; Tsuruta, Akihiro; Akamatsu, Takafumi; Izu, Noriya; Shin, Woosuck; Park, Jangchul; Hida, Toyoaki; Eda, Takeshi; Setoguchi, Yasuhiro
2016-01-01
Various volatile organic compounds (VOCs) in breath exhaled by patients with lung cancer, healthy controls, and patients with lung cancer who underwent surgery for resection of cancer were analyzed by gas condenser-equipped gas chromatography-mass spectrometry (GC/MS) for development of an exhaled breath monitoring prototype system involving metal oxide gas sensors, a gas condenser, and gas chromatography columns. The gas condenser-GC/MS analysis identified concentrations of 56 VOCs in the breath exhaled by the test population of 136 volunteers (107 patients with lung cancer and 29 controls), and selected four target VOCs, nonanal, acetoin, acetic acid, and propanoic acid, for use with the condenser, GC, and sensor-type prototype system. The prototype system analyzed exhaled breath samples from 101 volunteers (74 patients with lung cancer and 27 controls). The prototype system exhibited a level of performance similar to that of the gas condenser-GC/MS system for breath analysis. PMID:27834896
Effects of oxygen-enriched air on cognitive performance during SCUBA-diving - an open-water study.
Brebeck, Anne-Kathrin; Deussen, Andreas; Schmitz-Peiffer, Henning; Range, Ursula; Balestra, Costantino; Cleveland, Sinclair; Schipke, Jochen D
2017-01-01
Backround: Nitrogen narcosis impairs cognitive function, a fact relevant during SCUBA-diving. Oxygen-enriched air (nitrox) became popular in recreational diving, while evidence of its advantages over air is limited. Compare effects of nitrox28 and air on two psychometric tests. In this prospective, double-blind, open-water study, 108 advanced divers (38 females) were randomized to an air or a nitrox-group for a 60-min dive to 24 m salt water. Breathing gas effects on cognitive performance were assessed during the dive using a short- and long-term memory test and a number connection test. Nitrox28 divers made fewer mistakes only on the long-term memory test (p = 0.038). Female divers remembered more items than male divers (p < 0.001). There were no significant differences in the number connection test between the groups. Likely owing to the comparatively low N 2 reduction and the conservative dive, beneficial nitrox28 effects to diver performance were moderate but could contribute to diving safety.
In flight auscultation: comparison of electronic and conventional stethoscopes.
Tourtier, Jean P; Fontaine, Emmamuelle; Coste, Sébastien; Ramsang, Solange; Schiano, Patrick; Viaggi, Marie; Libert, Nicolas; Durand, Xavier; Chargari, Cyrus; Borne, Marc
2011-10-01
The ability to auscultate during air medical transport is compromised by high ambient noise levels. The aim of this study was to assess the capabilities of a traditional and an amplified stethoscope (which is expected to reduce background and ambient noise) to assess heart and breath sounds during medical transport in a Falcon 50 plane. A prospective, double-blind, randomized study was performed. We tested 1 model of traditional stethoscope (Littman cardiology III) and 1 model of amplified stethoscope (Littman 3100). We studied heart and lung auscultation during real medical evacuations aboard Falcon 50 (medically configured). For each, the quality of auscultation was described using a numeric rating scale (ranging from 0 to 10, with 0 corresponding to "I hear nothing" and 10 corresponding to "I hear perfectly"). Comparisons were accomplished using a t test for paired values. A total of 32 comparative evaluations were performed. For cardiac auscultation, the value of the rating scale was 5.8 ± 1.5 and 6.4 ± 1.9, respectively, for the traditional and amplified stethoscope (P = .018). For lung sounds, quality of auscultation was estimated at 3.3 ± 2.4 for traditional stethoscope and at 3.7 ± 2.9 for amplified stethoscope (P = .15). Practicians in Falcon 50 are more able to hear cardiac sounds with an amplified than with a traditional stethoscope, whereas there is no significant difference concerning breath sounds auscultation. Copyright © 2011 Elsevier Inc. All rights reserved.
Rabeprazole- versus esomeprazole-based eradication regimens for H. pylori infection.
Wu, I-Chen; Wu, Deng-Chyang; Hsu, Ping-I; Lu, Chien-Yu; Yu, Fang-Jung; Wang, Tsang-En; Chang, Wen-Hsiung; Chen, Jyh-Jon; Kuo, Fu-Chen; Wu, Jeng-Yih; Wang, Wen-Ming; Bair, Ming-Jong
2007-12-01
Different kinds of proton pump inhibitor-based triple therapies could result in different Helicobacter pylori eradication rates. The aims of this study were to compare the efficacy and safety of rabeprazole- and esomeprazole-based triple therapy in primary treatment of H. pylori infection in Taiwan. From June 2005 to March 2007, 420 H. pylori-infected patients were randomly assigned to receive a 7-day eradication therapy with either esomeprazole 40 mg daily (EAC group, n = 209) or rabeprazole 20 mg b.i.d. (RAC group, n = 211) in combination with amoxicillin 1 g b.i.d. and clarithromycin 500 mg b.i.d.. Follow-up endoscopy with biopsy was done 12-16 weeks after completion of eradication therapy. Those who refused endoscopic exams underwent (13)C-urea breath test to assess the treatment response. Intention-to-treat analysis revealed that the eradication rate was 89.4% in the EAC group and 90.5% in RAC groups (p-value = .72). All of the subjects returned for assessment of compliance (100% in EAC group vs. 99.5% in RAC group, p-value = .32) and adverse events (3.83% in EAC group vs. 6.16% in RAC group, p-value = .27). Sixty (28.7%) and 37 (17.6%) patients in EAC and RAC group, respectively, refused endoscopy and underwent a (13)C-urea breath test to determine the treatment effect. In conclusion, rabeprazole- and esomeprazole-based primary therapies for H. pylori infection are comparable in efficacy and safety.
Schmitt, Todd L; Munns, Suzanne; Adams, Lance; Hicks, James
2013-09-01
This study utilized computed spirometry to compare the pulmonary function of two stranded olive ridley sea turtles (Lepidochelys olivacea) presenting with a positive buoyancy disorder with two healthy captive olive ridley sea turtles held in a large public aquarium. Pulmonary function test (PFT) measurements demonstrated that the metabolic cost of breathing was much greater for animals admitted with positive buoyancy than for the normal sea turtles. Positively buoyant turtles had higher tidal volumes and significantly lower breathing-frequency patterns with significantly higher expiration rates, typical of gasp-type breathing. The resulting higher energetic cost of breathing in the diseased turtles may have a significant impact on their long-term survival. The findings represent a method for clinical respiratory function analysis for an individual animal to assist with diagnosis, therapy, and prognosis. This is the first study, to our knowledge, to evaluate objectively sea turtles presenting with positive buoyancy and respiratory disease using pulmonary function tests.
Chemoresponsiveness and breath physiology in anosmia.
Mazzatenta, Andrea; Pokorski, Mieczyslaw; Montinaro, Danilo; Di Giulio, Camillo
2015-01-01
Anosmia is a model to study the interaction among chemoreception systems. In the head injury, the traumatic irreversible anosmia caused by damage to olfactory nerve fibers and brain regions is of enviable research interest. In this study, psychophysiological tests for a comprehensive assessment of olfactory function were utilized to investigate anosmia, together with a new technique based on the breath real-time monitoring of volatile organic compounds (VOCs). We applied the breath and VOCs analysis to investigate chemoresponsiveness in the long-term irreversible post-traumatic anosmia.
Cowan, J Mack; Burris, James M; Hughes, James R; Cunningham, Margaret P
2010-06-01
The relationship between normal body temperature, end-expired breath temperature, and blood alcohol concentration (BAC)/breath alcohol concentration (BrAC) ratio was studied in 98 subjects (84 men, 14 women). Subjects consumed alcohol sufficient to produce a BrAC of at least 0.06 g/210 L 45-75 min after drinking. Breath samples were analyzed using an Intoxilyzer 8000 specially equipped to measure breath temperature. Venous blood samples and body temperatures were then taken. The mean body temperature of the men (36.6 degrees C) was lower than the women (37.0 degrees C); however, their mean breath temperatures were virtually identical (men: 34.5 degrees C; women: 34.6 degrees C). The BAC exceeded the BrAC for every subject. BAC/BrAC ratios were calculated from the BAC and BrAC analytical results. There was no difference in the BAC/BrAC ratios for men (1:2379) and women (1:2385). The correlation between BAC and BrAC was high (r = 0.938, p < 0.0001), whereas the correlations between body temperature and end-expired breath temperature, body temperature and BAC/BrAC ratio, and breath temperature and BAC/BrAC ratio were much lower. Neither normal body temperature nor end-expired breath temperature was strongly associated with BAC/BrAC ratio.
Kijima, Sho; Tanaka, Hideki
2016-01-01
This study aimed to evaluate changes in glucose metabolism at the early stage and onset of diabetes in Otsuka Long-Evans Tokushima Fatty (OLETF) rats. Specifically, after the oral administration of [1, 2, 3-13C]glucose, the levels of exhaled 13CO2, which most likely originated from pyruvate decarboxylation and tricarboxylic acid, were measured. Eight OLETF rats and eight control rats (Long-Evans Tokushima Otsuka [LETO]) were administered 13C-glucose. Three types of 13C-glucose breath tests were performed thrice in each period at 2-week intervals. [3-13C]glucose results in a 13C isotope at position 1 in the pyruvate molecule, which provides 13CO2. The 13C at carbons 1 and 2 of glucose is converted to 13C at carbons 2 and 1 of acetate, respectively, which produce 13CO2. Based on metabolic differences of the labeled sites, glucose metabolism was evaluated using the results of three breath tests. The increase in 13CO2 excretion in OLETF rats was delayed in all three breath tests compared to that in control rats, suggesting that OLETF rats had a lower glucose metabolism than control rats. In addition, overall glucose metabolism increased with age in both groups. The utilization of [2-13C]glucose was suppressed in OLETF rats at 6–12 weeks of age, but they showed higher [3-13C]glucose oxidation than control rats at 22–25 weeks of age. In the [1-13C]glucose breath test, no significant differences in the area under the curve until 180 minutes (AUC180) were observed between OLETF and LETO rats of any age. Glucose metabolism kinetics were different between the age groups and two groups of rats; however, these differences were not significant based on the overall AUC180 of [1-13C]glucose. We conclude that breath 13CO2 excretion is reduced in OLETF rats at the primary stage of prediabetes, indicating differences in glucose oxidation kinetics between OLETF and LETO rats. PMID:27483133
Kawagoe, Naoyuki; Kano, Osamu; Kijima, Sho; Tanaka, Hideki; Takayanagi, Masaaki; Urita, Yoshihisa
2016-01-01
This study aimed to evaluate changes in glucose metabolism at the early stage and onset of diabetes in Otsuka Long-Evans Tokushima Fatty (OLETF) rats. Specifically, after the oral administration of [1, 2, 3-13C]glucose, the levels of exhaled 13CO2, which most likely originated from pyruvate decarboxylation and tricarboxylic acid, were measured. Eight OLETF rats and eight control rats (Long-Evans Tokushima Otsuka [LETO]) were administered 13C-glucose. Three types of 13C-glucose breath tests were performed thrice in each period at 2-week intervals. [3-13C]glucose results in a 13C isotope at position 1 in the pyruvate molecule, which provides 13CO2. The 13C at carbons 1 and 2 of glucose is converted to 13C at carbons 2 and 1 of acetate, respectively, which produce 13CO2. Based on metabolic differences of the labeled sites, glucose metabolism was evaluated using the results of three breath tests. The increase in 13CO2 excretion in OLETF rats was delayed in all three breath tests compared to that in control rats, suggesting that OLETF rats had a lower glucose metabolism than control rats. In addition, overall glucose metabolism increased with age in both groups. The utilization of [2-13C]glucose was suppressed in OLETF rats at 6-12 weeks of age, but they showed higher [3-13C]glucose oxidation than control rats at 22-25 weeks of age. In the [1-13C]glucose breath test, no significant differences in the area under the curve until 180 minutes (AUC180) were observed between OLETF and LETO rats of any age. Glucose metabolism kinetics were different between the age groups and two groups of rats; however, these differences were not significant based on the overall AUC180 of [1-13C]glucose. We conclude that breath 13CO2 excretion is reduced in OLETF rats at the primary stage of prediabetes, indicating differences in glucose oxidation kinetics between OLETF and LETO rats.
Isotope-selective sensor for medical diagnostics based on PAS
NASA Astrophysics Data System (ADS)
Wolff, M.; Groninga, H. G.; Harde, H.
2005-06-01
Development of new optical sensor technologies has a major impact on the progression of diagnostic methods. Of the permanently increasing number of non-invasive 13C-breath tests, the Urea Breath Test for detection of Helicobacter pylori is the most prominent. However, many recent developments go beyond gastroenterological applications. We present a new detection scheme for breath analysis that employs an especially compact and simple set-up based on Photoacoustic Spectroscopy. Using a wavelength-modulated DFB-diode laser and taking advantage of acoustical resonances of the sample cell, we performed very sensitive isotope-selective measurements on CO2. Detection limits for 13CO2 of a few ppm and for the variation of the 13CO2 concentration of approximately 1% were achieved.
2011-01-01
Background Cigarette smoking is the number one cause of preventable death among American Indian and Alaska Natives, AI/ANs. Two out of every five AI/AN will die from tobacco-related diseases if the current smoking rates of AI/ANs (40.8%) persist. Currently, there is no proven, effective culturally-tailored smoking cessation program designed specifically for a heterogeneous population of AI. The primary aim of this group randomized clinical trial is to test the efficacy of "All Nations Breath of Life" (ANBL) program compared to a non-tailored "Current Best Practices" smoking cessation program among AI smokers. Methods We will randomize 56 groups (8 smokers per group) to the tailored program or non-tailored program for a total sample size of 448 American Indian smokers. All participants in the proposed study will be offered pharmacotherapy, regardless of group assignment. This study is the first controlled trial to examine the efficacy of a culturally-tailored smoking cessation program for American Indians. If the intervention is successful, the potential health impact is significant because the prevalence of smoking is the highest in this population. Trial Registration ClinicalTrials.gov: NCT01106456 PMID:21592347
Lindsay, Helen A; Hannam, Jacqueline A; Bradfield, Charles N; Mitchell, Simon J
2016-08-01
Appropriate hand hygiene reduces hospital-acquired infections. Anesthesiologists work in environments with numerous hand hygiene opportunities (HHOs). In a prospective observational study, we investigated the potential for an anesthesiologist to return a positive alcohol breath test during routine practice when using alcohol hand gel. We observed ten volunteer anesthesiologists over four hours while they implemented the World Health Organization (WHO) "five moments for hand hygiene" using our hospital's adopted standard 70% ethanol hand gel. We measured the expired alcohol concentration at shift start and every fifteen minutes thereafter with a fuel cell breathalyzer calibrated to measure the percentage of blood alcohol concentration (BAC). Blood alcohol specimens (analyzed with gas chromatography) were collected at shift start and, when possible, immediately after a participant's first positive breathalyzer test. Of the 130 breathalyzer tests obtained, there were eight (6.2%) positive breath alcohol results from six of the ten participants, all within two minutes of a HHO. The highest value breathalyzer BAC recorded was 0.064%, with an overall mean (SD) of 0.023 (0.017)%. Five (62.5%) of the positive breathalyzer tests returned to zero in less than seven minutes. All of three blood specimens obtained immediately after a positive breathalyzer reading tested negative for alcohol. Anesthesia practitioners using alcohol hand gel in a manner that conforms with recommended hand hygiene can test positive for alcohol on a breathalyzer assay. Positive tests probably arose from inhalation of alcohol vapour into the respiratory dead space following gel application. If workplace breath testing for alcohol is implemented, it should be completed more than 15 min after applying alcohol hand gel. Positive results should be verified with a BAC test.
Cheepsattayakorn, Attapon; Cheepsattayakorn, Ruangrong
2013-01-01
Today, exhaled nitric oxide has been studied the most, and most researches have now focusd on asthma. More than a thousand different volatile organic compounds have been observed in low concentrations in normal human breath. Alkanes and methylalkanes, the majority of breath volatile organic compounds, have been increasingly used by physicians as a novel method to diagnose many diseases without discomforts of invasive procedures. None of the individual exhaled volatile organic compound alone is specific for disease. Exhaled breath analysis techniques may be available to diagnose and monitor the diseases in home setting when their sensitivity and specificity are improved in the future. PMID:24151617
Monitoring of endogenous carbon monoxide dynamics in human breath by tunable diode laser
NASA Astrophysics Data System (ADS)
Stepanov, Eugene V.; Daraselia, Mikhail V.; Zyrianov, Pavel V.; Shulagin, Yurii A.; Skrupskii, Vladimir A.
1996-01-01
High sensitive CO gas analyzer based on tunable diode laser (TDL) was used as a real time monitor of endogenous carbon monoxide in a set of breath physiology experiments. The measurements of the CO content dynamics in exhaled air with 10 ppb sensitivity were attended with detection of carbon dioxide and O2 in breath, lung ventilation parameters, heart rate and blood analysis using conventional techniques. Temporal variations of endogenous CO in human breath caused by hyperoxia, hypoxia, hyperventilation and sport loading were first studied in real time. Scattering of the CO variation time constants was observed for different tested persons. Possible reasons for this scattering related with the organisms' physiology peculiarities are discussed.
Endogenous CO dynamics monitoring in breath by tunable diode laser
NASA Astrophysics Data System (ADS)
Kouznetsov, Andrian I.; Stepanov, Eugene V.; Shulagin, Yurii A.; Skrupskii, Vladimir A.
1996-04-01
High sensitive CO gas analyzer based on tunable diode laser (TDL) was used as a real time monitor of endogenous carbon monoxide in a set of breath physiology experiments. The measurements of the CO content dynamics in exhaled air with 10 ppb sensitivity were attended with detection of carbon dioxide and O2 in breath, lung ventilation parameters, heart rate and blood analysis using conventional techniques. Variations of endogenous CO in human breath caused by hyperoxia, hypoxia, hyperventilation as well as sport loading were studied in real time. Scattering of the CO variation time constants was observed for different tested persons. Possible reasons for this scattering related with the organisms' physiology peculiarities are discussed.
Twice-daily cimetidine does not increase gastric bacterial flora.
Bourne, J. T.; Mountford, R. A.; Barry, R. E.
1984-01-01
Thirty patients with peptic ulcer (20 duodenal, 10 gastric) underwent glucose-hydrogen (H2) breath tests before and after 6 weeks treatment with cimetidine, 400 mg twice daily. For the group as a whole, basal breath H2 and integrated H2 output over a 2.5 hr test period was unchanged by cimetidine treatment. We conclude that there was no evidence of significant gastric bacterial colonization following twice daily cimetidine treatment. PMID:6462995
Respiratory modulation of human autonomic function on Earth.
Eckberg, Dwain L; Cooke, William H; Diedrich, André; Biaggioni, Italo; Buckey, Jay C; Pawelczyk, James A; Ertl, Andrew C; Cox, James F; Kuusela, Tom A; Tahvanainen, Kari U O; Mano, Tadaaki; Iwase, Satoshi; Baisch, Friedhelm J; Levine, Benjamin D; Adams-Huet, Beverley; Robertson, David; Blomqvist, C Gunnar
2016-10-01
We studied healthy supine astronauts on Earth with electrocardiogram, non-invasive arterial pressure, respiratory carbon dioxide concentrations, breathing depth and sympathetic nerve recordings. The null hypotheses were that heart beat interval fluctuations at usual breathing frequencies are baroreflex mediated, that they persist during apnoea, and that autonomic responses to apnoea result from changes of chemoreceptor, baroreceptor or lung stretch receptor inputs. R-R interval fluctuations at usual breathing frequencies are unlikely to be baroreflex mediated, and disappear during apnoea. The subjects' responses to apnoea could not be attributed to changes of central chemoreceptor activity (hypocapnia prevailed); altered arterial baroreceptor input (vagal baroreflex gain declined and muscle sympathetic nerve burst areas, frequencies and probabilities increased, even as arterial pressure climbed to new levels); or altered pulmonary stretch receptor activity (major breathing frequency and tidal volume changes did not alter vagal tone or sympathetic activity). Apnoea responses of healthy subjects may result from changes of central respiratory motoneurone activity. We studied eight healthy, supine astronauts on Earth, who followed a simple protocol: they breathed at fixed or random frequencies, hyperventilated and then stopped breathing, as a means to modulate and expose to view important, but obscure central neurophysiological mechanisms. Our recordings included the electrocardiogram, finger photoplethysmographic arterial pressure, tidal volume, respiratory carbon dioxide concentrations and peroneal nerve muscle sympathetic activity. Arterial pressure, vagal tone and muscle sympathetic outflow were comparable during spontaneous and controlled-frequency breathing. Compared with spontaneous, 0.1 and 0.05 Hz breathing, however, breathing at usual frequencies (∼0.25 Hz) lowered arterial baroreflex gain, and provoked smaller arterial pressure and R-R interval fluctuations, which were separated by intervals that were likely to be too short and variable to be attributed to baroreflex physiology. R-R interval fluctuations at usual breathing frequencies disappear during apnoea, and thus cannot provide evidence for the existence of a central respiratory oscillation. Apnoea sets in motion a continuous and ever changing reorganization of the relations among stimulatory and inhibitory inputs and autonomic outputs, which, in our study, could not be attributed to altered chemoreceptor, baroreceptor, or pulmonary stretch receptor activity. We suggest that responses of healthy subjects to apnoea are driven importantly, and possibly prepotently, by changes of central respiratory motoneurone activity. The companion article extends these observations and asks the question, Might terrestrial responses to our 20 min breathing protocol find expression as long-term neuroplasticity in serial measurements made over 20 days during and following space travel? Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
Respiratory modulation of human autonomic function on Earth
Cooke, William H.; Diedrich, André; Biaggioni, Italo; Buckey, Jay C.; Pawelczyk, James A.; Ertl, Andrew C.; Cox, James F.; Kuusela, Tom A.; Tahvanainen, Kari U. O.; Mano, Tadaaki; Iwase, Satoshi; Baisch, Friedhelm J.; Levine, Benjamin D.; Adams‐Huet, Beverley; Robertson, David; Blomqvist, C. Gunnar
2016-01-01
Key points We studied healthy supine astronauts on Earth with electrocardiogram, non‐invasive arterial pressure, respiratory carbon dioxide concentrations, breathing depth and sympathetic nerve recordings.The null hypotheses were that heart beat interval fluctuations at usual breathing frequencies are baroreflex mediated, that they persist during apnoea, and that autonomic responses to apnoea result from changes of chemoreceptor, baroreceptor or lung stretch receptor inputs.R‐R interval fluctuations at usual breathing frequencies are unlikely to be baroreflex mediated, and disappear during apnoea.The subjects’ responses to apnoea could not be attributed to changes of central chemoreceptor activity (hypocapnia prevailed); altered arterial baroreceptor input (vagal baroreflex gain declined and muscle sympathetic nerve burst areas, frequencies and probabilities increased, even as arterial pressure climbed to new levels); or altered pulmonary stretch receptor activity (major breathing frequency and tidal volume changes did not alter vagal tone or sympathetic activity). Apnoea responses of healthy subjects may result from changes of central respiratory motoneurone activity. Abstract We studied eight healthy, supine astronauts on Earth, who followed a simple protocol: they breathed at fixed or random frequencies, hyperventilated and then stopped breathing, as a means to modulate and expose to view important, but obscure central neurophysiological mechanisms. Our recordings included the electrocardiogram, finger photoplethysmographic arterial pressure, tidal volume, respiratory carbon dioxide concentrations and peroneal nerve muscle sympathetic activity. Arterial pressure, vagal tone and muscle sympathetic outflow were comparable during spontaneous and controlled‐frequency breathing. Compared with spontaneous, 0.1 and 0.05 Hz breathing, however, breathing at usual frequencies (∼0.25 Hz) lowered arterial baroreflex gain, and provoked smaller arterial pressure and R‐R interval fluctuations, which were separated by intervals that were likely to be too short and variable to be attributed to baroreflex physiology. R‐R interval fluctuations at usual breathing frequencies disappear during apnoea, and thus cannot provide evidence for the existence of a central respiratory oscillation. Apnoea sets in motion a continuous and ever changing reorganization of the relations among stimulatory and inhibitory inputs and autonomic outputs, which, in our study, could not be attributed to altered chemoreceptor, baroreceptor, or pulmonary stretch receptor activity. We suggest that responses of healthy subjects to apnoea are driven importantly, and possibly prepotently, by changes of central respiratory motoneurone activity. The companion article extends these observations and asks the question, Might terrestrial responses to our 20 min breathing protocol find expression as long‐term neuroplasticity in serial measurements made over 20 days during and following space travel? PMID:27028958
DOT National Transportation Integrated Search
1980-02-01
The performance of breath alcohol test equipment used by : police is a major concern of the alcohol countermeasures effort : of the National Highway Traffic Safety Administration (NHTSA). : A Qualified Products List (QPL) has been established to ensu...
Variables that Impact on the Results of Breath-Alcohol Tests
ERIC Educational Resources Information Center
Labianca, Dominick A.
2004-01-01
In a 2003 issue of the "Journal of Chemical Education," Kniesel and Bellamy describe a timely and pedagogically effective experiment involving breath-alcohol analysis using an FTIR (Fourier Transform Infrared Spectroscopy) spectrometer. The present article clarifies some of the information presented in the 2003 article.
Diagnosis of Peptic Ulcer Disease
... urea breath test, you will drink a special liquid that contains urea, a waste product that your body makes as it breaks down protein. If H. pylori are present, the bacteria will change this waste product into carbon dioxide—a harmless gas. Carbon dioxide normally appears in your breath when ...
Ju, Yu-Jeng; Lien, Yunn-Wen
2016-02-01
It has been suggested that unwanted thoughts usually intrude during mind wandering due to a shortage of mental resources. However, strategies for suppressing such thoughts have never been examined from a mind wandering perspective. Here, we compare the effectiveness of two types of attention distraction strategies that either redirect users' attention to their own breathing (focused-breathing strategy, FBS) or to a mental image (focused-distraction strategy, FDS) as related to working memory capacities. Eighty-two undergraduates were randomly assigned into a FBS or FDS group. They completed a concentration task and a thought suppression task, in which mind wandering and thought intrusions were each measured. Our results support the hypothesis that mind wandering is positively correlated to thought intrusions and shows that FBS is more effective than FDS in reducing mind wandering and thought intrusions. Moreover, in contrast to FDS, the effect of FBS is independent of users' mental resources. Copyright © 2015 Elsevier Inc. All rights reserved.
Barletta, Michele; Almondia, Donna; Williams, Jamie; Crochik, Sonia; Hofmeister, Erik
2014-01-01
This study documents the degree of positional atelectasis in sedated dogs receiving 100% oxygen (O2) versus room air. Initial lateral recumbency was determined by an orthopedic study and initial treatment (O2 or room air) was randomized. Each dog was maintained in lateral recumbency for 15 min, at which time ventrodorsal (VD) and opposite lateral thoracic radiographs were obtained. Each dog was then maintained in the opposite lateral recumbency and received the other treatment for 15 min, followed by a VD and opposite lateral radiograph. Radiographs were scored for severity of pulmonary pattern and mediastinal shift by 3 radiologists. Dogs breathing O2 had significantly higher scores than dogs breathing room air. If radiographically detectable dependent atelectasis is present, repeat thoracic images following manual positive ventilation and/or position change to the opposite lateral recumbency should be made to rule out the effect of O2 positional atelectasis and avoid misdiagnosis. PMID:25320389
USDA-ARS?s Scientific Manuscript database
We sought to determine the efficacy of psyllium fiber treatment on abdominal pain and stool patterns in children with irritable bowel syndrome (IBS). We evaluated effects on breath hydrogen and methane production, gut permeability, and microbiome composition. We also investigated whether psychologic...
Correlation of Respirator Fit Measured on Human Subjects and a Static Advanced Headform
Bergman, Michael S.; He, Xinjian; Joseph, Michael E.; Zhuang, Ziqing; Heimbuch, Brian K.; Shaffer, Ronald E.; Choe, Melanie; Wander, Joseph D.
2015-01-01
This study assessed the correlation of N95 filtering face-piece respirator (FFR) fit between a Static Advanced Headform (StAH) and 10 human test subjects. Quantitative fit evaluations were performed on test subjects who made three visits to the laboratory. On each visit, one fit evaluation was performed on eight different FFRs of various model/size variations. Additionally, subject breathing patterns were recorded. Each fit evaluation comprised three two-minute exercises: “Normal Breathing,” “Deep Breathing,” and again “Normal Breathing.” The overall test fit factors (FF) for human tests were recorded. The same respirator samples were later mounted on the StAH and the overall test manikin fit factors (MFF) were assessed utilizing the recorded human breathing patterns. Linear regression was performed on the mean log10-transformed FF and MFF values to assess the relationship between the values obtained from humans and the StAH. This is the first study to report a positive correlation of respirator fit between a headform and test subjects. The linear regression by respirator resulted in R2 = 0.95, indicating a strong linear correlation between FF and MFF. For all respirators the geometric mean (GM) FF values were consistently higher than those of the GM MFF. For 50% of respirators, GM FF and GM MFF values were significantly different between humans and the StAH. For data grouped by subject/respirator combinations, the linear regression resulted in R2 = 0.49. A weaker correlation (R2 = 0.11) was found using only data paired by subject/respirator combination where both the test subject and StAH had passed a real-time leak check before performing the fit evaluation. For six respirators, the difference in passing rates between the StAH and humans was < 20%, while two respirators showed a difference of 29% and 43%. For data by test subject, GM FF and GM MFF values were significantly different for 40% of the subjects. Overall, the advanced headform system has potential for assessing fit for some N95 FFR model/sizes. PMID:25265037
Emtner, Margareta; Porszasz, Janos; Burns, Mary; Somfay, Attila; Casaburi, Richard
2003-11-01
Supplemental oxygen improves exercise tolerance of normoxemic and hypoxemic chronic obstructive pulmonary disease (COPD) patients. We determined whether nonhypoxemic COPD patients undergoing exercise training while breathing supplemental oxygen achieve higher intensity and therefore improve exercise capacity more than patients breathing air. A double-blinded trial was performed involving 29 nonhypoxemic patients (67 years, exercise SaO2 > 88%) with COPD (FEV1 = 36% predicted). All exercised on cycle ergometers for 45 minutes, 3 times per week for 7 weeks at high-intensity targets. During exercise, they received oxygen (3 L/minute) (n = 14) or compressed air (3 L/minute) (n = 15). Both groups had a higher exercise tolerance after training and when breathing oxygen. However, the oxygen-trained group increased the training work rate more rapidly than the air-trained group. The mean +/- SD work rate during the last week was 62 +/- 19 W (oxygen-trained group) and 52 +/- 22 W (air-trained group) (p < 0.01). After training, endurance in constant work rate tests increased more in the oxygen-trained group (14.5 minutes) than in the air-trained group (10.5 minutes) (p < 0.05). At isotime, the breathing rate decreased four breaths per minute in the oxygen-trained group and one breath per minute in the air-trained group (p = 0.001). We conclude that supplemental oxygen provided during high-intensity training yields higher training intensity and evidence of gains in exercise tolerance in laboratory testing.
Luján, Manel; Sogo, Ana; Pomares, Xavier; Monsó, Eduard; Sales, Bernat; Blanch, Lluís
2013-05-01
New home ventilators are able to provide clinicians data of interest through built-in software. Monitoring of tidal volume (VT) is a key point in the assessment of the efficacy of home mechanical ventilation. To assess the reliability of the VT provided by 5 ventilators in a bench test. Five commercial ventilators from 4 different manufacturers were tested in pressure support mode with the help of a breathing simulator under different conditions of mechanical respiratory pattern, inflation pressure, and intentional leakage. Values provided by the built-in software of each ventilator were compared breath to breath with the VT monitored through an external pneumotachograph. Ten breaths for each condition were compared for every tested situation. All tested ventilators underestimated VT (ranges of -21.7 mL to -83.5 mL, which corresponded to -3.6% to -14.7% of the externally measured VT). A direct relationship between leak and underestimation was found in 4 ventilators, with higher underestimations of the VT when the leakage increased, ranging between -2.27% and -5.42% for each 10 L/min increase in the leakage. A ventilator that included an algorithm that computes the pressure loss through the tube as a function of the flow exiting the ventilator had the minimal effect of leaks on the estimation of VT (0.3%). In 3 ventilators the underestimation was also influenced by mechanical pattern (lower underestimation with restrictive, and higher with obstructive). The inclusion of algorithms that calculate the pressure loss as a function of the flow exiting the ventilator in commercial models may increase the reliability of VT estimation.
Wilder-Smith, C H; Olesen, S S; Materna, A; Drewes, A M
2017-04-01
Diets low in fermentable sugars (low-FODMAP diets) are increasingly adopted by patients with functional gastrointestinal disorders (FGID), but outcome predictors are unclear. To identify factors predictive of an efficacious response to a low-FODMAP diet in FGID patients with fructose or lactose intolerance thereby gaining insights into underlying mechanisms. Fructose and lactose breath tests were performed in FGID patients to determine intolerance (positive symptom score) and malabsorption (increased hydrogen or methane concentrations). Patients with fructose or lactose intolerance consumed a low-FODMAP diet and global adequate symptom relief was assessed after 6-8 weeks and correlated with pre-diet clinical symptoms and breath test results. A total of 81% of 584 patients completing the low-FODMAP diet achieved adequate relief, without significant differences between FGID subgroups or types of intolerance. Univariate analysis yielded predictive factors in fructose intolerance (chronic diarrhoea and pruritus, peak methane concentrations and fullness during breath tests) and lactose intolerance (peak hydrogen and methane concentrations and flatulence during breath tests). Using multivariate analysis, symptom relief was independently and positively predicted in fructose intolerance by chronic diarrhoea [odds ratio (95% confidence intervals): 2.62 (1.31-5.27), P = 0.007] and peak breath methane concentrations [1.53 (1.02-2.29), P = 0.042], and negatively predicted by chronic nausea [0.33 (0.16-0.67), P = 0.002]. No independent predictive factors emerged for lactose intolerance. Adequate global symptom relief was achieved with a low-FODMAP diet in a large majority of functional gastrointestinal disorders patients with fructose or lactose intolerance. Independent predictors of a satisfactory dietary outcome were only seen in fructose intolerant patients, and were indicative of changes in intestinal host or microbiome metabolism. © 2017 John Wiley & Sons Ltd.
Respiratory Outcomes of the Surfactant Positive Pressure and Oximetry Randomized Trial
Stevens, Timothy P.; Finer, Neil N.; Carlo, Waldemar A.; Szilagyi, Peter G.; Phelps, Dale L.; Walsh, Michele C.; Gantz, Marie G.; Laptook, Abbot R.; Yoder, Bradley A.; Faix, Roger G.; Newman, Jamie E.; Das, Abhik; Do, Barbara T.; Schibler, Kurt; Rich, Wade; Newman, Nancy S.; Ehrenkranz, Richard A.; Peralta-Carcelen, Myriam; Vohr, Betty R.; Wilson-Costello, Deanne E.; Yolton, Kimberly; Heyne, Roy J.; Evans, Patricia W.; Vaucher, Yvonne E.; Adams-Chapman, Ira; McGowan, Elisabeth C.; Bodnar, Anna; Pappas, Athina; Hintz, Susan R.; Acarregui, Michael J.; Fuller, Janell; Goldstein, Ricki F.; Bauer, Charles R.; O’Shea, T. Michael; Myers, Gary J.; Higgins, Rosemary D.
2014-01-01
Objective To explore the early childhood pulmonary outcomes of infants who participated in the NICHD SUPPORT Trial, using a factorial design that randomized extremely preterm infants to lower vs. higher oxygen saturation targets and delivery room CPAP vs. intubation/surfactant, found no significant difference in the primary composite outcome of death or BPD. Study design The Breathing Outcomes Study, a prospective secondary to SUPPORT, assessed respiratory morbidity at 6 month intervals from hospital discharge to 18–22 months corrected age (CA). Two pre-specified primary outcomes, wheezing more than twice per week during the worst 2 week period and cough longer than 3 days without a cold were compared between each randomized intervention. Results One or more interviews were completed for 918 of 922 eligible infants. The incidence of wheezing and cough were 47.9% and 31.0%, respectively, and did not differ between study arms of either randomized intervention. Infants randomized to lower vs. higher oxygen saturation targets had similar risks of death or respiratory morbidities (except for croup, treatment with oxygen or diuretics at home). Infants randomized to CPAP vs. intubation/surfactant had fewer episodes of wheezing without a cold (28.9% vs. 36.5%, p<0.05), respiratory illnesses diagnosed by a doctor (47.7% vs. 55.2%, p<0.05) and physician or emergency room visits for breathing problems (68.0% vs. 72.9%, p<0.05) by 18–22 months CA. Conclusion Treatment with early CPAP rather than intubation/surfactant is associated with less respiratory morbidity by 18–22 months CA. Longitudinal assessment of pulmonary morbidity is necessary to fully evaluate the potential benefits of respiratory interventions for neonates. PMID:24725582
Effect of Raw Milk on Lactose Intolerance: A Randomized Controlled Pilot Study
Mummah, Sarah; Oelrich, Beibei; Hope, Jessica; Vu, Quyen; Gardner, Christopher D.
2014-01-01
PURPOSE This pilot study aimed to determine whether raw milk reduces lactose malabsorption and/or lactose intolerance symptoms relative to pasteurized milk. METHODS We performed a crossover trial involving 16 adults with self-reported lactose intolerance and lactose malabsorption confirmed by hydrogen (H2) breath testing. Participants underwent 3, 8-day milk phases (raw vs 2 controls: pasteurized, soy) in randomized order separated by 1-week washout periods. On days 1 and 8 of each phase, milk consumption was 473 mL (16 oz); on days 2 to 7, milk dosage increased daily by 118 mL (4 oz), beginning with 118 mL (4 oz) on day 2 and reaching 710 mL (24 oz) on day 7. Outcomes were area under the breath H2 curve (AUC ∆H2) and self-reported symptom severity (visual analog scales: flatulence/gas, audible bowel sounds, abdominal cramping, diarrhea). RESULTS AUC ∆H2 (mean ± standard error of the mean) was higher for raw vs pasteurized on day 1 (113 ± 21 vs 71 ± 12 ppm·min·10−2, respectively, P = .01) but not day 8 (72 ± 14 vs 74 ± 15 ppm·min·10−2, respectively, P = .9). Symptom severities were not different for raw vs pasteurized on day 7 with the highest dosage (P >.7). AUC ∆H2 and symptom severities were higher for both dairy milks compared with soy milk. CONCLUSIONS Raw milk failed to reduce lactose malabsorption or lactose intolerance symptoms compared with pasteurized milk among adults positive for lactose malabsorption. These results do not support widespread anecdotal claims that raw milk reduces the symptoms of lactose intolerance. PMID:24615309
Effect of raw milk on lactose intolerance: a randomized controlled pilot study.
Mummah, Sarah; Oelrich, Beibei; Hope, Jessica; Vu, Quyen; Gardner, Christopher D
2014-01-01
This pilot study aimed to determine whether raw milk reduces lactose malabsorption and/or lactose intolerance symptoms relative to pasteurized milk. We performed a crossover trial involving 16 adults with self-reported lactose intolerance and lactose malabsorption confirmed by hydrogen (H2) breath testing. Participants underwent 3, 8-day milk phases (raw vs 2 controls: pasteurized, soy) in randomized order separated by 1-week washout periods. On days 1 and 8 of each phase, milk consumption was 473 mL (16 oz); on days 2 to 7, milk dosage increased daily by 118 mL (4 oz), beginning with 118 mL (4 oz) on day 2 and reaching 710 mL (24 oz) on day 7. Outcomes were area under the breath H2 curve (AUC H2) and self-reported symptom severity (visual analog scales: flatulence/gas, audible bowel sounds, abdominal cramping, diarrhea). AUC H2 (mean ± standard error of the mean) was higher for raw vs pasteurized on day 1 (113 ± 21 vs 71 ± 12 ppm·min·10(-2), respectively, P = .01) but not day 8 (72 ± 14 vs 74 ± 15 ppm·min·10(-2), respectively, P = .9). Symptom severities were not different for raw vs pasteurized on day 7 with the highest dosage (P >.7). AUC H2 and symptom severities were higher for both dairy milks compared with soy milk. Raw milk failed to reduce lactose malabsorption or lactose intolerance symptoms compared with pasteurized milk among adults positive for lactose malabsorption. These results do not support widespread anecdotal claims that raw milk reduces the symptoms of lactose intolerance.
Bock, Beth C; Rosen, Rochelle K.; Fava, Joseph L.; Gaskins, Ronnesia B.; Jennings, Ernestine; Thind, Herpreet; Carmody, James; Dunsiger, Shira I; Gidron, Naama; Becker, Bruce M.; Marcus, Bess H.
2014-01-01
Smokers trying to quit encounter many challenges including nicotine withdrawal symptoms, cigarette craving, increased stress and negative mood and concern regarding weight gain. These phenomena make it difficult to successfully quit smoking. Studies in non-smoking populations show that yoga reduces stress and negative mood and improves weight control. By increasing mindfulness we anticipate that yoga may also improve smokers’ ability to cope with the negative symptoms associated with quitting. Yoga may also improve cognitive deliberation which is needed to make effective choices and avoid smoking in tempting situations. The BreathEasy study is a rigorous, randomized controlled clinical trial examining the efficacy of Iyengar yoga as a complementary therapy to cognitive-behavioral therapy for smoking cessation. All participants are given an 8-week program of smoking cessation classes, and are randomized to either twice weekly yoga (Yoga) or twice-weekly health and wellness classes which serve as a control for contact and participant burden (CTL). Assessments are conducted at baseline, 8 weeks, 3, 6, and 12 months follow up. The primary outcome is prolonged abstinence using an intention-to-treat approach. Multiple internal and external audits using blind data collection are employed to ensure treatment fidelity and reliability of study results. To understand why yoga may be more effective than CTL, we will examine mechanisms of action (i.e., mediators) underlying intervention efficacy. We will examine maintenance of yoga practice and smoking status at each follow up. Focus groups and interviews will be used to enrich our understanding of the relationship of yoga practice and smoking abstinence. PMID:24937018
Karalus, Melinda; Clark, Michelle; Greaves, Kathryn A; Thomas, William; Vickers, Zata; Kuyama, Megumi; Slavin, Joanne
2012-09-01
Fiber is thought to enhance satiety, although not all fibers are equally effective. Colonic fermentation may influence satiety and food intake. To test the satiating properties of four isolated fibers added to chocolate crisp bars. Within-subject preload design with repeated measures. Each participant completed five conditions, presented in random order. Participants were 22 adult women who do not practice restrained eating (body mass index 18 to 29). The experimental conditions were four fiber treatments: 10 g oligofructose, inulin, soluble corn fiber, or resistant wheat starch in chocolate crisp bars. A no-added-fiber bar was evaluated as the control. The night before each treatment, participants consumed a dinner bar containing 10 g of the same fiber given the next morning. Repeated ratings of feelings related to hunger and fullness at the lunch meal were the main measures. Secondary outcomes included breath hydrogen and methane, gastrointestinal symptoms, energy consumed at an ad libitum lunch, and energy from 24-hour dietary recall. Mixed-effect linear models with random intercept for participants to model within-subject correlation. All treatments were well tolerated. No differences were found in subjective satiety during the morning or food intake at lunch or over 24 hours. The oligofructose bar produced the greatest increase in breath hydrogen, and the most bloating and flatulence symptoms. Functional fibers incorporated into chocolate bars at high fiber doses produce greater gastrointestinal symptoms than control, but do not alter satiety, hunger, or food intake compared with control in the short term. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Nesthus, Thomas E.; Schiflett, Samuel G.; Oakley, Carolyn J.
1992-01-01
Current military aircraft Liquid Oxygen (LOX) systems supply 99.5 pct. gaseous Aviator's Breathing Oxygen (ABO) to aircrew. Newer Molecular Sieve Oxygen Generation Systems (MSOGS) supply breathing gas concentration of 93 to 95 pct. O2. The margin is compared of hypoxia protection afforded by ABO and MSOGS breathing gas after a 5 psi differential rapid decompression (RD) in a hypobaric research chamber. The barometric pressures equivalent to the altitudes of 46000, 52000, 56000, and 60000 ft were achieved from respective base altitudes in 1 to 1.5 s decompressions. During each exposure, subjects remained at the simulated peak altitude breathing either 100 or 94 pct. O2 with positive pressure for 60 s, followed by a rapid descent to 40000 ft. Subjects used the Tactical Life Support System (TLSS) for high altitude protection. Subcritical tracking task performance on the Performance Evaluation Device (PED) provided psychomotor test measures. Overall tracking task performance results showed no differences between the MSOGS breathing O2 concentration of 94 pct. and ABO. Significance RMS error differences were found between the ground level and base altitude trials compared to peak altitude trials. The high positive breathing pressures occurring at the peak altitudes explained the differences.
NASA Astrophysics Data System (ADS)
Mansfield, C. D.; Rutt, H. N.
2002-02-01
The possible generation of spurious results, arising from the application of infrared spectroscopic techniques to the measurement of carbon isotope ratios in breath, due to coincident absorption bands has been re-examined. An earlier investigation, which approached the problem qualitatively, fulfilled its aspirations in providing an unambiguous assurance that 13C16O2/12C16O2 ratios can be confidently measured for isotopic breath tests using instruments based on infrared absorption. Although this conclusion still stands, subsequent quantitative investigation has revealed an important exception that necessitates a strict adherence to sample collection protocol. The results show that concentrations and decay rates of the coincident breath trace compounds acetonitrile and carbon monoxide, found in the breath sample of a heavy smoker, can produce spurious results. Hence, findings from this investigation justify the concern that breath trace compounds present a risk to the accurate measurement of carbon isotope ratios in breath when using broadband, non-dispersive, ground state absorption infrared spectroscopy. It provides recommendations on the length of smoking abstention required to avoid generation of spurious results and also reaffirms, through quantitative argument, the validity of using infrared absorption spectroscopy to measure CO2 isotope ratios in breath.
Aspiration tests in aqueous foam using a breathing simulator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Archuleta, M.M.
1995-12-01
Non-toxic aqueous foams are being developed by Sandia National Laboratories (SNL) for the National Institute of Justice (NIJ) for use in crowd control, cell extractions, and group disturbances in the criminal justice prison systems. The potential for aspiration of aqueous foam during its use and the resulting adverse effects associated with complete immersion in aqueous foam is of major concern to the NIJ when examining the effectiveness and safety of using this technology as a Less-Than-Lethal weapon. This preliminary study was designed to evaluate the maximum quantity of foam that might be aspirated by an individual following total immersion inmore » an SNL-developed aqueous foam. A.T.W. Reed Breathing simulator equipped with a 622 Silverman cam was used to simulate the aspiration of an ammonium laureth sulfate aqueous foam developed by SNL and generated at expansion ratios in the range of 500:1 to 1000:1. Although the natural instinct of an individual immersed in foam is to cover their nose and mouth with a hand or cloth, thus breaking the bubbles and decreasing the potential for aspiration, this study was performed to examine a worst case scenario where mouth breathing only was examined, and no attempt was made to block foam entry into the breathing port. Two breathing rates were examined: one that simulated a sedentary individual with a mean breathing rate of 6.27 breaths/minute, and one that simulated an agitated or heavily breathing individual with a mean breathing rate of 23.7 breaths/minute. The results of this study indicate that, if breathing in aqueous foam without movement, an air pocket forms around the nose and mouth within one minute of immersion.« less
de Waal, Cornelia G; Kraaijenga, Juliette V; Hutten, Gerard J; de Jongh, Frans H; van Kaam, Anton H
2017-12-01
To compare triggering, breath detection and delay time of the Graseby capsule (GC) and transcutaneous electromyography of the diaphragm (dEMG) in spontaneous breathing preterm infants. In this observational study, a 30 minutes respiration measurement was conducted by respiratory inductance plethysmography (RIP), the GC, and dEMG in stable preterm infants. Triggering was investigated with an in vitro set-up using the Infant Flow ® SiPAP TM system. The possibility to optimize breath detection was tested by developing new algorithms with the abdominal RIP band (RIP AB ) as gold standard. In a subset of breaths, the delay time was calculated between the inspiratory onset in the RIP AB signal and in the GC and dEMG signal. Fifteen preterm infants with a mean gestational age of 28 ± 2 weeks and a mean birth weight of 1086 ± 317 g were included. In total, 14 773 breaths were analyzed. Based on the GC and dEMG signal, the Infant Flow ® SiPAP™ system, respectively, triggered 67.8% and 62.6% of the breaths. Breath detection was improved to 99.9% for the GC and 113.4% for dEMG in new algorithms. In 1492 stable breaths, the median delay time of inspiratory onset detection was +154 ms (IQR +118 to +164) in the GC and -50 ms (IQR -90 to -22) in the dEMG signal. Breath detection using the GC can be improved by optimizing the algorithm. Transcutaneous dEMG provides similar breath detection but with the advantage of detecting the onset of inspiration earlier than the GC. © 2017 Wiley Periodicals, Inc.
Establishment of a Quick and Highly Accurate Breath Test for ALDH2 Genotyping
Aoyama, Ikuo; Ohashi, Shinya; Amanuma, Yusuke; Hirohashi, Kenshiro; Mizumoto, Ayaka; Funakoshi, Makiko; Tsurumaki, Mihoko; Nakai, Yukie; Tanaka, Katsuyuki; Hanada, Mariko; Uesaka, Aki; Chiba, Tsutomu; Muto, Manabu
2017-01-01
Objectives: Acetaldehyde, the first metabolite of ethanol, is a definite carcinogen for the esophagus, head, and neck; and aldehyde dehydrogenase 2 (ALDH2) is a mitochondrial enzyme that catalyzes the metabolism of acetaldehyde. The ALDH2 genotype exists as ALDH2*1/*1 (active ALDH2), ALDH2*1/*2 (heterozygous inactive ALDH2), and ALDH2*2/*2 (homozygous inactive ALDH2). Many epidemiological studies have reported that ALDH2*2 carriers are at high risk for esophageal or head and neck squamous cell carcinomas by habitual drinking. Therefore, identification of ALDH2*2 carriers would be helpful for the prevention of those cancers, but there have been no methods suitable for mass screening to identify these individuals. Methods: One hundred and eleven healthy volunteers (ALDH2*1/*1 carriers: 53; ALDH2*1/*2 carriers: 48; and ALDH2*2/*2 carriers: 10) were recruited. Breath samples were collected after drinking 100 ml of 0.5% ethanol using specially designed gas bags, and breath ethanol and acetaldehyde levels were measured by semiconductor gas chromatography. Results: The median (range) breath acetaldehyde levels at 1 min after alcohol ingestion were 96.1 (18.1–399.0) parts per billion (p.p.b.) for the ALDH2*1/*1 genotype, 333.5 (78.4–1218.4) p.p.b. for the ALDH2*1/*2 genotype, and 537.1 (213.2–1353.8) p.p.b. for the ALDH2*2/*2 genotype. The breath acetaldehyde levels in ALDH2*2 carriers were significantly higher than for the ALDH2*1/*1 genotype. Notably, the ratio of breath acetaldehyde level-to-breath ethanol level could identify carriers of the ALDH2*2 allele very accurately (whole accuracy; 96.4%). Conclusions: Our novel breath test is a useful tool for identifying ALDH2*2 carriers, who are at high risk for esophageal and head and neck cancers. PMID:28594397
Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit
NASA Technical Reports Server (NTRS)
Meginnis, Ian M.; Norcross, Jason; Bekdash, Omar; Ploutz-Snyder, Robert
2016-01-01
A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient pressure testing of space suits, the oronasal mask fails to meet several human factors and operational criterion needed for future sub-ambient pressure testing (e.g. compatibility with a Valsalva device). This paper describes the evaluation of a nasal cannula as a device for measuring inspired air within a space suit. Eight test subjects were tasked with walking on a treadmill or operating an arm ergometer to achieve target metabolic rates of 1000, 2000, and 3000 British thermal units per hour (BTU/hr), at flow rates of 2, 4, and 6 actual cubic feet per minute (ACFM). Each test configuration was conducted twice, with subjects instructed to breathe either through their nose only, or however they felt comfortable. Test data shows that the nasal cannula provides more statistically consistent data across test subjects than the oronasal mask used in previous tests. The data also shows that inhaling/exhaling through only the nose provides a lower sample variance than a normal breathing style. Nose-only breathing reports better CO2 washout due to several possible reasons, including a decreased respiratory rate, an increased tidal volume, and because nose-only breathing directs all of the exhaled CO2 down and away from the oronasal region. The test subjects in this study provided feedback that the nasal cannula is comfortable and can be used with the Valsalva device.
The current investigation was designed and conducted to examine the body kinetic behaviors by means of breath analysis under various exposure conditions to test the validity of using exhaled breath as a biological marker of exposure.
DOT National Transportation Integrated Search
1989-05-01
This study was undertaken, on request, to evaluate the performance of the Puritan-Bennett portable crew protective breathing device for contaminant leaks. O2, CO2 levels, inhalation/exhalation pressure, and inhalation temperature. Tests were conducte...
2017-06-12
In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, Jacobs Test and Operations Support Contract, or TOSC, technicians fill portable breathing apparatuses, or PBAS. The PBAs are to be use on board the International Space Staton to provide astronauts with breathable air in the event of a fire or other emergency situation.
Crew equipment applications - Firefighter's Breathing System.
NASA Technical Reports Server (NTRS)
Smith, W. L.
1973-01-01
The Firefighter's Breathing System (FBS) represents a significant step in applying NASA's crew equipment technologists and technologies to civilian sector problems. This paper describes the problem, the utilization of user-design committees as a forum for development of design goals, the design of the FBS, and the field test program to be conducted.
Ventilation Increases with Lower Extremity Venous Occlusion in Young Adults
Keller-Ross, Manda L.; Cowl, Andrielle L.; Cross, Troy; Johnson, Bruce D.; Olson, Thomas P.
2015-01-01
Introduction Venous distention via sub-systolic occlusion of the lower limbs may augment ventilation via stimulation of group III/IV afferent neurons. Purpose The purpose of this study was to examine the ventilatory response to graded lower extremity venous occlusion during exercise in healthy adults. Methods Nineteen adults (9 men, 25±5 yr) completed two visits. Visit 1: a maximal cycle ergometry exercise test. Visit 2 included a 30% peak workload cycle exercise with randomized inflations of bilateral thigh pressure tourniquets to 20, 40, 60, 80, 100 mmHg for 2 min each, separated by 2 min of deflation. Three min of cycling occurred prior to cuffing (CTL). Expired minute ventilation (VE), whole body gas exchange, rating of perceived exertion and dyspnea were measured during each session. Results VE increased significantly from the control condition (exercise only, control, CTL) to each occlusion pressure (p<0.05) with the greatest increase at 100 mmHg (CTL to 100 mmHg: 31.5±6.6 to 40.1±10.7 L/min). Respiratory rate (RR) increased as well (CTL to 100 mmHg: 24.8±6.0 to 30.9±11.5 breaths/min, p<0.05, condition effect) with no change in tidal volume (p>0.05). Tidal volume to inspiratory time (VT/TI) increased significantly from the CTL condition to each occlusion pressure (CTL to 100 mmHg: 1.5±0.3 to 1.8±0.4 L/min, p<0.05, all pressures). Dyspnea and RPE increased with all occlusion pressures from CTL exercise (p<0.05, all pressures). Conclusion Our findings suggest that mild-to-moderate venous occlusion of the lower extremity evokes a tachypneic breathing pattern which, in turn, augments VE and perceived breathing effort during exercise. PMID:26484951
Critchley, Hugo D.; Nicotra, Alessia; Chiesa, Patrizia A.; Nagai, Yoko; Gray, Marcus A.; Minati, Ludovico; Bernardi, Luciano
2015-01-01
Controlled slow breathing (at 6/min, a rate frequently adopted during yoga practice) can benefit cardiovascular function, including responses to hypoxia. We tested the neural substrates of cardiorespiratory control in humans during volitional controlled breathing and hypoxic challenge using functional magnetic resonance imaging (fMRI). Twenty healthy volunteers were scanned during paced (slow and normal rate) breathing and during spontaneous breathing of normoxic and hypoxic (13% inspired O2) air. Cardiovascular and respiratory measures were acquired concurrently, including beat-to-beat blood pressure from a subset of participants (N = 7). Slow breathing was associated with increased tidal ventilatory volume. Induced hypoxia raised heart rate and suppressed heart rate variability. Within the brain, slow breathing activated dorsal pons, periaqueductal grey matter, cerebellum, hypothalamus, thalamus and lateral and anterior insular cortices. Blocks of hypoxia activated mid pons, bilateral amygdalae, anterior insular and occipitotemporal cortices. Interaction between slow breathing and hypoxia was expressed in ventral striatal and frontal polar activity. Across conditions, within brainstem, dorsal medullary and pontine activity correlated with tidal volume and inversely with heart rate. Activity in rostroventral medulla correlated with beat-to-beat blood pressure and heart rate variability. Widespread insula and striatal activity tracked decreases in heart rate, while subregions of insular cortex correlated with momentary increases in tidal volume. Our findings define slow breathing effects on central and cardiovascular responses to hypoxic challenge. They highlight the recruitment of discrete brainstem nuclei to cardiorespiratory control, and the engagement of corticostriatal circuitry in support of physiological responses that accompany breathing regulation during hypoxic challenge. PMID:25973923
Bench test evaluation of adaptive servoventilation devices for sleep apnea treatment.
Zhu, Kaixian; Kharboutly, Haissam; Ma, Jianting; Bouzit, Mourad; Escourrou, Pierre
2013-09-15
Adaptive servoventilation devices are marketed to overcome sleep disordered breathing with apneas and hypopneas of both central and obstructive mechanisms often experienced by patients with chronic heart failure. The clinical efficacy of these devices is still questioned. This study challenged the detection and treatment capabilities of the three commercially available adaptive servoventilation devices in response to sleep disordered breathing events reproduced on an innovative bench test. The bench test consisted of a computer-controlled piston and a Starling resistor. The three devices were subjected to a flow sequence composed of central and obstructive apneas and hypopneas including Cheyne-Stokes respiration derived from a patient. The responses of the devices were separately evaluated with the maximum and the clinical settings (titrated expiratory positive airway pressure), and the detected events were compared to the bench-scored values. The three devices responded similarly to central events, by increasing pressure support to raise airflow. All central apneas were eliminated, whereas hypopneas remained. The three devices responded differently to the obstructive events with the maximum settings. These obstructive events could be normalized with clinical settings. The residual events of all the devices were scored lower than bench test values with the maximum settings, but were in agreement with the clinical settings. However, their mechanisms were misclassified. The tested devices reacted as expected to the disordered breathing events, but not sufficiently to normalize the breathing flow. The device-scored results should be used with caution to judge efficacy, as their validity depends upon the initial settings.
Scheenstra, Renske J; Muller, Saar H; Vincent, Andrew; Ackerstaff, Annemieke H; Jacobi, Irene; Hilgers, Frans J M
2011-05-01
To assess the endotracheal temperature and humidity and clinical effects of 2 models of a new heat and moisture exchanger (HME): Rplus, which has regular breathing resistance, and Lplus, which has lower breathing resistance. We measured endotracheal temperature and humidity in 10 laryngectomized patients, for 10 min each, with and without the HMEs. We sequentially tested 4 HME models (all Atos Medical, Hörby, Sweden), in randomized order: Rplus, Lplus, Provox Normal (the HME we regularly use and which we considered the reference HME), and Stomvent (an older HME model). We also assessed the short-term clinical and practical effects of the Rplus and Lplus in a prospective 3-week trial with 13 laryngectomized patients. Rplus and Lplus had better humidification than Provox Normal (6.8 mg H(2)O/L, 4.3 mg H(2)O/L, and 3.7 mg H(2)O/L, respectively, P < .001), and no significant temperature difference. During the 3-week study period, 7 of the 13 patients reported noticeably lower mucus production with Rplus and Lplus. Rplus and Lplus had better heating and humidification than Provox Normal. Although Stomvent also performed well, its design is less convenient for laryngectomized patients. Further HME improvement is still warranted and should focus on improving the HME's heating capacity.
49 CFR 40.267 - What problems always cause an alcohol test to be cancelled?
Code of Federal Regulations, 2011 CFR
2011-10-01
... the case of a screening test conducted on a saliva ASD or a breath tube ASD: (1) The STT or BAT reads... § 40.245(a)(8) for the saliva ASD and § 40.245(b)(8) for the breath tube ASD). (2) The saliva ASD does... printed on the device or on its package (see § 40.245(a)(1) for the saliva ASD and § 40.245(b)(1) for the...
Botngård, Anja; Skranes, Lars P; Skranes, Jon; Døllner, Henrik
2013-12-01
To determine whether multimedia based health information presented to parents of children with breathing difficulties in a pediatric acute ward, is more effective than verbal information, to reduce parental anxiety and increase satisfaction. This randomized controlled trial was conducted in a pediatric acute ward in Norway, from January to March 2011. Parents were randomly assigned to a multimedia intervention (n=53), or verbal health information (n=48). Primary outcome measure was parental anxiety, and secondary outcome measures were parental satisfaction with nursing care and health information. Parental anxiety decreased from arrival to discharge within both groups. At discharge the anxiety levels in the intervention group were no lower than in the control group. There was no difference in satisfaction with nursing care between the groups, but parents in the intervention group reported higher satisfaction with the health information given in the acute ward (p=.005). Multimedia based health information did not reduce anxiety more than verbal information, among parents to children with breathing difficulties. However, after discharge the parents were more satisfied with the multimedia approach. More research is needed to recommend the use of multimedia based information as a routine to parents in pediatric emergency care. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
de Oliveira, Sergius A. R.; Lucio, Lorena M. C.; Modolo, Norma S. P.; Hayashi, Yoko; Braz, Mariana G.; de Carvalho, Lídia R.; Braz, Leandro G.; Braz, José Reinaldo C.
2017-01-01
Background During anesthesia, as compared with intensive care, the time of the tracheal intubation is much shorter. An inhaled gas minimum humidity of 20 mgH2O.L-1 is recommended to reduce the deleterious effects of dry gas on the airways during anesthesia with tracheal intubation. The Fabius GS Premium® anesthesia workstation (Dräger Medical, Lübeck, Germany) has a built-in hotplate to heat gases in the breathing circuit. A heat and moisture exchanger (HME) is used to further heat and humidify the inhaled gas. The humidity of the gases in the breathing circuit is influenced by the ambient temperature. We compared the humidity of the inhaled gases from a low-flow Fabius anesthesia workstation with or without thermal insulation (TI) of the breathing circuit and with or without an HME. Methods We conducted a prospective randomized trial in 41 adult female patients who underwent elective abdominal surgery. The patients were allocated into four groups according to the devices used to ventilate their lungs using a Dräger Fabius anesthesia workstation with a low gas flow (1 L.min-1): control, with TI, with an HME or with TI and an HME (TIHME). The mean temperature and humidity of the inhaled gases were measured during 2-h after connecting the patients to the breathing circuit. Results The mean inhaled gas temperature and absolute humidity were higher in the HME (29.2±1.3°C; 28.1±2.3 mgH2O·L-1) and TIHME (30.1±1.2°C; 29.4±2.0 mgH2O·L-1) groups compared with the control (27.5±1.0°C; 25.0±1.8 mgH2O·L-1) and TI (27.2±1.1°C; 24.9±1.8 mgH2O·L-1) groups (P = 0.003 and P<0.001, respectively). Conclusions The low-flow Fabius GS Premium breathing circuit provides the minimum humidity level of inhaled gases to avoid damage to the tracheobronchial epithelia during anesthesia. TI of the breathing circuit does not increase the humidity of the inhaled gases, whereas inserting an HME increases the moisture of the inhaled gases closer to physiological values. PMID:28129353
Grams, Samantha Torres; Kimoto, Karen Yumi Mota; Azevedo, Elen Moda de Oliveira; Lança, Marina; Albuquerque, André Luis Pereira de; Brito, Christina May Moran de; Yamaguti, Wellington Pereira
2015-01-01
Maximal Inspiratory Pressure (MIP) is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway. This study aimed to compare the MIP values assessed by standard method (MIPsta) and by unidirectional expiratory valve method (MIPuni) in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated. This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B) at two moments (Tests 1 and 2) to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1]) was used to determine intraobserver and interobserver reproducibility. The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O) than the mean values for MIPsta (-102.5 ± 23.9 cmH2O) (p<0.001). Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91), and high correlation for Test 2 (ICC[2,1] = 0.88). The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86) and evaluator B (ICC[2,1] = 0.77). MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway.
Bin, Zhang; Ya-Zheng, Xu; Zhao-Hui, Deng; Bo, Chu; Li-Rong, Jiang
2015-01-01
Purpose This study aims to investigate Saccharomyces boulardii CNCM I-745 during Helicobacter pylori eradication in children. Methods One hundred ninety-four H. pylori positive children were randomized in two groups. Therapy (omeprazole+clarithromycin+amoxicillin or omeprazole+clarithromycin+metronidazole in case of penicillin allergy) was given to both groups during two weeks. In the treatment group (n: 102) S. boulardii was added to the triple therapy, while the control group (n: 92) only received triple therapy. The incidence, onset, duration and severity of diarrhea and compliance to the eradication treatment were compared. A 13C urea breath test was done 4 weeks after the end of eradication therapy in two groups of 21 patients aged 12 years and older to test the H. pylori eradication rate. Results In the treatment group, diarrhea occurred in 12 cases (11.76%), starting after 6.25±1.24 days, lasting 3.17±1.08 days, and compliance to eradication treatment was 100%. In the control group, diarrhea occurred in 26 cases (28.26%), starting after 4.05±1.11 days, lasting 4.02±0.87 days, and in six cases eradication treatment was stopped prematurely (p<0.05). The 13C urea breath test showed successful H. pylori eradication in 71.4% of the patients in the treatment and in 61.9 % in the control group (not significant). Conclusion S. boulardii has a beneficial effect on the prevention and treatment of diarrhea during H. pylori eradication in children. Although S. boulardii did only slightly increase H. pylori eradication rate, compliance to eradication treatment was improved. PMID:25866729
Modak, Anil S; Klyarytska, Iryna; Kriviy, Valerij; Tsapyak, Tatjana; Rabotyagova, Yliya
2016-12-17
Patients with gastroesophageal reflux disease (GERD) are routinely prescribed one of the six FDA approved proton pump inhibitors (PPI). All of these PPI are inhibitors of CYP2C19 enzyme to varying degrees. The phenotype pantoprazole- 13 C breath test (Ptz-BT) was used to identify patients who are poor metabolizers (PM) and the extent of phenoconversion of CYP2C19 enzyme activity caused by four PPI (omeprazole, esomprazole pantoprazole and rabeprazole) in 54 newly diagnosed GERD patients prior to initiating randomly selected PPI therapy and 30 d after PPI therapy. The phenoconversion after 30 d of PPI therapy in GERD patients was statistically significant (p =0.001) with omeprazole/esomeprazole (n = 27) strong CYP2C19 inhibitors, while there was no change in CYP2C19 enzyme activity (p = 0.8) with pantoprazole/ rabeprazole (n = 27), weak CYP2C19 inhibitors. The concommitant use of omeprazole/esomeprazole, therefore, could have critical clinical relevance in individualizing medications metabolized primarily by CYP2C19 such as PPI, clopidogrel, phenytoin, cyclophosphamide, thalidomide, citalopram, clonazepam, diazepam, proguanil, tivantinib etc. The rapid (30 min), in vivo, and non-invasive phenotype Ptz-BT can evaluate CYP2C19 enzyme activity. More importantly, it can identify GERD patients with low CYP2C19 enzyme activity (PM), caused by PPI or other concomitant medications, who would benefit from dose adjustments to maintain efficacy and avoid toxicity. The existing CYP2C19 genotype tests cannot predict the phenotype nor can it detect phenoconversion due to non genetic factors.
[Breath tests in children with suspected lactose intolerance].
Parra, P Ángela; Furió, C Simone; Arancibia, A Gabriel
2015-01-01
Up to 70% of the world population is lactose intolerance. However, there are no epidemiological studies among Chilean pediatric population affected by this condition. Clinical characterization of a series of children who underwent the lactose intolerance breath test for lactose intolerance study, establishing intolerance and malabsorption frequencies, the most frequent symptoms, and test performance depending on the origin. Patients under 18 years old who took the lactose intolerance breath test in the Gastroenterology Laboratory of the Catholic University of Chile, and who were admitted due to clinically suspected lactose intolerance. Malabsorption was considered when there was as an increase of ≥20ppm above the baseline (H2) or ≥34ppm of H2 and methane (CH4) combined. Intolerance was considered when the above was associated with a symptom intensity score ≥7 during registration. The analysis included194 patients aged 1 to17 years of age. Of these, 102 (53%) presented with malabsorption, and 53 (27%) were intolerant. The frequency of lactose intolerance varied from 7.1 to 45.4%, and it occurred more frequently at older ages. The most common reported symptoms were abdominal pain, bloating and rumbling. Lactose malabsorption and intolerance can be investigated from the first years of life using the lactose breath test plus a symptom questionnaire. An increase in the frequency of intolerance with age, and a greater number of positive tests, if they were requested by a gastroenterologist, were observed. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.
Measurement of breath acetone in patients referred for an oral glucose tolerance test.
Andrews, Brian Terence; Denzer, Wolfgang; Hancock, Gus; Lunn, Dan; Peverall, Robert; Ritchie, Grant; Williams, Karen
2018-04-12
Breath acetone concentrations were measured in 141 subjects (aged 19-91 yrs, mean=59.11yrs standard deviation=12.99yrs), male and female, undergoing an oral glucose tolerance test (OGTT), having been referred to clinic on suspicion of type 2 diabetes. Breath samples were measured using an ion-molecule-reaction mass spectrometer, at the commencement of the OGTT, and after 1 and 2hrs. Subjects were asked to observe the normal routine before and during the OGTT, which includes an overnight fast and ingestion of 75g glucose at the beginning of the routine. Several groups of diagnosis were identified: type 2 Diabetes Mellitus positive (T2DM), n=22; impaired glucose intolerance (IGT), n=33; impaired fasting glucose (IFG), n=14; and reactive hypoglycaemia (RHG), n=5. The subjects with no diagnosis (i.e. normoglycaemia) were used as a control group, n=67. Distributions of breath acetone are presented for the different groups. There was no evidence of a direct relationship between blood glucose and acetone measurements at any time during the study (0hr: p=0.4482; 1hr: p=0.6854; and 2hr: p=0.1858). Nor were there significant differences between the measurements of breath acetone for the control group and the T2DM group (0hr: p=0.1759; 1hr: p=0.4521; and 2hr: p=0.7343). However, the ratio of breath acetone at 1hr to the initial breath acetone was found to be significantly different for the T2DM group compared to both the control and IGT groups (p=0.0189 and 0.011, respectively). The T2DM group was also found to be different in terms of ratio of breath acetone after 1hr to that at 2hrs during the OGTT. And was distinctive in that it showed a significant dependence upon the level of blood glucose at 2hrs (p=0.0146). We conclude that single measurements of the concentrations of breath acetone cannot be used as a potential screening diagnostic for T2DM diabetes in this cohort, but monitoring the evolution of breath acetone could open a non-invasive window to aid in the diagnosis of metabolic conditions. © 2018 IOP Publishing Ltd.
Effects of respiration depth on human body radar cross section Using 2.4GHz continuous wave radar.
Lee, Alexander; Xiaomeng Gao; Jia Xu; Boric-Lubecke, Olga
2017-07-01
In this study, it was tested whether deep and shallow breathing has an effect on the cardiopulmonary radar cross-section (RCS). Continuous wave radar with quadrature architecture at 2.4GHz was used to test 2 human subjects breathing deep and shallow for 30 seconds each while seated 2 meters away from the radar. A retro-reflective marker was placed on the sternum of each subject and measured by infrared motion capture cameras to accurately track displacement of the chest. The quadrature radar outputs were processed to find the radius of the arc on the IQ plot using a circle-fitting algorithm. Results showed that the effective RCS ratio of deep to shallow breathing for subjects 1 and 2 was 6.99 and 2.24 respectively.
Chan, Agnes S.; Cheung, Mei-Chun; Sze, Sophia L.; Leung, Winnie Wing-Man; Shi, Dejian
2011-01-01
Neuro-electrophysiological studies on meditative breathing revealed its association with either a relaxed or an attentive state. The present study aimed to investigate whether the Shaolin Dan Tian Breathing (DTB) technique, which consists of the Passive and Active subtypes and can be considered as a relaxation exercise and Qigong, would induce both relaxed and attentive states. Twenty-two adults and 22 age-, gender- and education-matched controls received training on the Shaolin DTB (experimental group) and the progressive muscle relaxation respectively for one month. Eyes-closed resting EEG data before and immediately after each type of breathing were obtained individually at baseline and after one-month training. At baseline, the EEG changes after the Shaolin DTB between both groups were comparable. After one-month training, participants in the experimental, but not the control, group showed enhanced temporal alpha asymmetry (an index of relaxation and positive mood) after performing the Passive DTB for five minutes, and enhanced intra- and inter-hemispheric theta coherence (an index of attention and alertness) after performing the Active DTB. The present findings suggested a positive effect of the Shaolin DTB technique on enhancing human neural activity and connectivity, which may possibly enhance mood state and cognitive functions. PMID:20976126